Loading...
HomeMy WebLinkAboutCDP 16-27; TABATA RANCH LOT 3; DESIGN OF ALLAN BLOCK SEGMENTAL WALL; 2016-11-22ABIENGINEERING CONSUL TANTS, INC. 1701 East Edinger Avenue, Suite A9, Santa Ana, California 92705 Tel.: (888) 220-5596 Fax: (714) 866-4171 E-Mail: abi@abiconsultants.com DESIGN OF ALLAN BLOCK SEGMENTAL WALL Tabata Family Trust - Lot 3 Strawberry Place Carlsbad, California DEC 0 52016 Prepared for: Homeland Engineering, Inc. 11337 Moreno Avenue Lakeside, California 92040 November 22, 2016 Project No. 16221 ABI Engineering Consultants, Inc. 1701 East Edinger Avenue, Suite A9 Santa Ana, California 92705 Tel: (888) 220-5596 Fax: (714) 866-4171 Allan Block Wall Design Tabata Family Trust - Lot 3, Carlsbad, CA TABLE OF CONTENTS INTRODUCTION..........................................................................................................................1 PROPOSED WALL DESCRIPTION .......................................................................................... 1 DESIGN METHODOLOGY ........................................................................................................ 1 SEISMIC DESIGN METHOD ..................................................................................................... 1 DESIGNPARAMETERS ............................................................................................................. 1 SoilsParameters .........................................................................................................................1 WallParameters ......................................................................................................................... 1 ANALYSIS.....................................................................................................................................2 StaticAnalysis.............................................................................................................................2 SeismicAnalysis..........................................................................................................................2 RECOMMENDATIONS...............................................................................................................2 REFERENCES...............................................................................................................................2 ABI Engineering Consultants, Inc. ABI Project No. 16221 Allan Block Wall Design Tabata Family Trust - Lot 3, Carlsbad, CA INTRODUCTION This report presents the design parameters, design methodology, and calculations performed to design proposed one segmental block retaining walls using Allan Block units at Tabata Family Trust - Lot 3, Strawberry Place, Carlsbad, California. The proposed retaining wall will be utilized to create building pad. PROPOSED WALL DESCRIPTION Based on our review of the grading plan provided (Rancho Coastal), one Allan Block retaining wall is proposed within the property. This wall is labelled as Allan Block Wall #1 for reference in this report. The maximum height of the walls will be 7.00nft. DESIGN METHODOLOGY The computer code AB Walls 15 Version 15.1.5 developed by Allan Block Corporation is used for the design of the wall. The computer code is based on the methods presented in National Concrete Masonry Association guidelines (NCMA 2010). The NCMA method of design of segmental block walls uses Coulomb Earth Pressure theory. AB Walls 15 program is customized for use with Allan Block and allows specifying choice of block types and geogrids reinforcement. The results of the analysis are included as Appendix A. The analysis was performed for different heights and surcharge conditions, as applicable. SEISMIC DESIGN METHOD The seismic internal stability of the Allan Block segmental wall is explored using AB Wall 15, which incorporates pseudo-static rigid body approach that adopts the Mononobe-Okabe method to calculate dynamic forces (NCMA 2010). A seismic acceleration coefficient of 0.32g is used in the seismic analysis. DESIGN PARAMETERS Soils Parameters Based on the recommendations provided in the geotechnical report (Vinje & Middleton) the following soils parameters are used for the design of the wall: Reinforced Fill Retained Soils Foundation Soils Internal Friction Angle, cb° 30 30 30 Cohesion, C (jsf) 0 0 0 Soil Unit Weight, y (pcf) 120 120 120 Wall Parameters BLOCKS: 12-inch deep Allan Block Units weighing approximately 75 lbs each. SURCHARGE: 2H: IV Backfill slope. BATTER: 15 degrees to vertical. EMBEDMENT: 0.5' or 10% of wall height (minimum). GEOGRIDS: Design is based on Fortrac 35/20-20 manufactured by Huesker and Mirafi Miragrid 3XT manufactured by TenCate. Equivalent or higher grade can be used. Other types of grids may be used upon approval by the engineer. The design of the retaining wall assumes no build up of hydrostatic pressures within the reinforced fill zone of the wall. Therefore, construction of an effective subdrain system behind the reinforced soil zone is critical to the performance of the wall. Any back-cut drain required shall be determined by the project geotechnical engineer and shall be installed per the direction of the project geotechnical engineer. ABI Engineering Consultants, Inc. ABI Project No. 16221 Allan Block Wall Design Tabata Family Trust - Lot 3, Carlsbad, CA ANALYSIS The wall design is based on the following factor of safety (FS) for stability analysis of the wall. The factors of safety are for static loading conditions are indicated below and are based on the current standard of practice. Static Analysis FSSljdjng = 1.50, FSsearing = 2.00, FSvertuming = 1.50, FSpuu.out = 1.50, and FSn ainties = 1.50 Seismic Analysis FSsluding = 1. 13, FSaearing = 1.50, FSovemirning = 1.13, = 1. 13, and FSnajn = 1.13 The summary calculations present the data and results for each section of the wall. RECOMMENDATIONS The wall shall be constructed per the details and geogrid reinforcement schedule based on the design calculations provided in this report, typical section, reinforcement schedule, and construction notes presented on drawings. The Allan Block walls shall be constructed per the manufacturer's recommended procedures. No substitution shall be allowed for blocks type or for the unit fill required within the units and behind the blocks. The foundation, retained, and backfill soils shall have the minimum shear strength properties as used for design in this report. All backfill shall be placed in loose lifts not exceeding 8 inches, moisture conditioned, and compacted to a minimum of 90% of the maximum dry density determined by Modified Proctor compaction test (ASTM D1557). The compaction tests shall be performed on backfill soils for meeting the minimum densities recommended. Any changes to foundation, retained and backfill soil properties and loading conditions on the wall should be brought to our attention. The temporary excavation back-cut, grading, ground improvement, fill settlement control, and sub-drain, and surface-drainage system for the Allan Block walls shall be per the Project Soils and Civil Engineer's recommendations. NCMA 2010, Design Manual for Segmental Retaining Walls, Third Edition, 2010. Allan Block Engineering Manual, Allan Block Corporation. Rancho Coastal Engineering & Surveying, Grading Plan, Tabata Family Trust - Lot 3, Strawberry Place, Carlsbad, California, dated November 17, 2016. Vinje & Middleton Engineering, Inc., Geotechnical Update Report and Grading Plan Review, Proposed Tabata Ranch Subdivision, Lemon Leaf Drive, Carlsbad, California, dated August 2, 2006. ABI Engineering Consultants, Inc. 2 ABI Project No. 16221 Allan Block Wall Design Tabata Family Trust - Lot 3, Carlsbad, CA APPENDIX A - Design Calculations ABI Engineering Consultants, Inc. ABl Project No. 16221