HomeMy WebLinkAbout1040 CARLSBAD VILLAGE DR; ; CBRA2020-0070; PermitPERMIT REPORT
(city of
Carlsbad
Residential Associated Permit
Print Date: 07/08/2022
Job Address: 1040 CARLSBAD VILLAGE DR, CARLSBAD, CA 92008
Permit Type: BLDG-Associated Permit Residential Work Class: Apartments
Parcel#:
Valuation: $24,993,078.34
Occupancy Group: R2, B, M, A2, A3, 52
#of Dwelling Units: 106
Bedrooms:
Bathrooms:
Project Title: CARLSBAD VILLAGE LOFTS
Track#:
Lot#:
Project#: DEV16014
Plan#:
Construction Type: I-A, V-A
Orig. Plan Check#: PC2019-0052
Plan Check#:
Permit No: CBRA2020-0070
Status: Closed -Finaled
Applied: 01/22/2020
Issued: 05/19/2020
Fina led Close Out: 11/04/2021
Inspector:
Final Inspection:
TKers
10/26/2021
Description: CARLSBAD VILLAGE LOFTS: 130,680 SF APARTMENT BUILDING W/ 106 UNITS// 5,778 SF BALCONIES// 80,089 SF PARKING
STRUCTURE
Property Owner:
CARLSBAD VILLAGE PARTNERS LP
3444 CAMINO DEL RIO N
FEE
BUILDING PLAN CHECK FEE (BLDG)
SDCWA SYSTEM CAPACITY 3"
SAN DIEGO, CA 92108-1710
ELECTRICAL BLDG RESIDENTIAL NEW/ ADDITION/REMODEL
TRAFFIC IMPACT Residential Apartments Outside CFD
PUBLIC FACILITIES FEES -outside CFD
BUILDING PERMIT FEE ($2000+)
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
WATER TREATMENT CAPACITY 3"
SEWER CONNECTION FEE (General Capacity all areas)
WATER METER FEE 3" (P)
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
STRONG MOTION-RESIDENTIAL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
WATER SERVICE CONNECTION 3" DISPLACEMENT (P)
SB1473 GREEN BUILDING STATE STANDARDS FEE
BUILDING PLAN CHECK FEE (BLDG)
SDCWA SYSTEM CAPACITY 3"
ELECTRICAL BLDG RESIDENTIAL NEW/ ADDITION/REMODEL
TRAFFIC IMPACT Residential Apartments Outside CFD
PUBLIC FACILITIES FEES -outside CFD
BUILDING PERMIT FEE ($2000+)
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
WATER TREATMENT CAPACITY 3"
SEWER CONNECTION FEE (General Capacity all areas)
WATER METER FEE 3" (P)
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
STRONG MOTION-RESIDENTIAL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
WATER SERVICE CONNECTION 3" DISPLACEMENT (P)
SB1473 GREEN BUILDING STATE STANDARDS FEE
Total Fees: $2,772,189.80 Total Payments To Date: $2,772,189.80
Contractor:
WERMERS MULTI-FAMILY CORP -INACTIVE
5120 SHOREHAM PL, # STE 150
SAN DIEGO, CA 92122-5959
(858) 535-1475
Balance Due:
AMOUNT
$0.00
$50,890.00
$830.00
$242,952.00
$874,757.74
$51,282.06
$55.00
$1,669.00
$246.00
$1,411.00
$104,092.00
$3,914.00
$2,091.00
$3,249.10
$175.00
$47,481.00
$1,000.00
$0.00
$50,890.00
$830.00
$242,952.00
$874,757.74
$51,282.06
$55.00
$1,669.00
$246.00
$1,411.00
$104,092.00
$3,914.00
$2,091.00
$3,249.10
$175.00
$47,481.00
$1,000.00
$0.00
1635 Faraday Avenue I Carlsbad, CA 92008-7314 I 442-339-2719 I 760-602-8560 f I www.carlsbadca.gov
'• v', n"+,1 ,,,~ , , , '" ,, , \, f:, ',,,\ :~4 /4 ,
. ,,: • • 0::t·~-~-, 11:1NSPECTIOtfJ1.I~TORY fbftcs~2Q:a0-:-0070) . :
Permit Type: BLDG-Associated Permit Residenti,
Work Class: Apartments
Status: Closed -Finaled
Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Issue Date: 05119/2020 Subdivision:
Expiration Date: 12/27/2021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD. CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
10/26/2021 10/26/2021 BLDG-Final Inspection 169383-2021
COMMENTS
Passed Tim Kersch
Tuesday, October 26, 2021
Checklist Item
BLOG-Building Deficiency
BLDG-Plumbing Final
BLOG-Mechanical Final
BLOG-Structural Final
BLDG-Electrical Final
Partial unit's on card
Final final.
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Page 36 of 36
Permit Type: BLDG-Associated Permit Residenti,
Work Class: Apartments
Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Status:
Scheduled
Date
08/2012021
08/2312021
08/26/2021
0911712021
10/2012021
Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
Actual Inspection Type
Start Date
Checklist Item
Inspection No.
COMMENTS
Inspection
Status
Primary Inspector
BLOG-Building Deficiency
BLDG-Plumbing Final
BLOG-Mechanical Final
BLDG-Structural Final
BLOG-Electrical Final
Partial inspection for final. Noted on card.
08/20/2021 BLDG-Final Inspection
Checklist Item
164621-2021
COMMENTS
Partial Pass Tim Kersch
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Partial inspection for final. Noted on card.
08/23/2021 BLDG-Final Inspection
Checklist ttem
164844-2021
COMMENTS
Partial Pass Tim Kersch
BLOG-Building Deficiency
BLDG-Plumbing Final
BLOG-Mechanical Final
BLDG-Structural Final
BLOG-Electrical Final
Partial inspection for final. Noted on card.
08/26/2021 BLDG-Final Inspection
Checklist Item
165071-2021
COMMENTS
Partial Pass Tim Kersch
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Partial inspection for final. Noted on card.
09/16/2021 BLDG-Fire Final
Checklist Item
FIRE-Building Final
1012012021 BLDG-Fire Final
Checklist Item
FIRE-Building Final
166627-2021
COMMENTS
Partial Pass Nathaniel Cheung
Need fire access AM&M approval
Need fire map with necessary location
169005-2021
COMMENTS
10120121
Fire final OK
9/17121
Passed Nathaniel Cheung
Need fire access AM&M approval
Need fire map with necessary location
Reinspection Inspection
Passed
Yes
Yes
Yes
Yes
Yes
Re inspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Reinspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Reinspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Re inspection Incomplete
Passed
No
Complete
Passed
Yes
Tuesday, October 26, 2021 Page 35 of 36
Permit Type: BLDG-Associated Permit Residenti,
Work Class: Apartments
Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Status:
Scheduled
Date
07/20/2021
07/26/2021
07/30/2021
08/10/2021
08/12/2021
Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
Checklist Item COMMENTS
BLDG-Building Deficiency Partial unit's on card
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
07/20/2021 BLDG•Flnal Inspection 162328-2021 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-Plumbing Final Partial inspection for final. Noted on card.
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
07/26/2021 BLDG~Flnal Inspection 162803-2021 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLDG-Building Deficiency Partial unit's on card
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
07/30/2021 BLDG-Final Inspection 163256-2021 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-Plumbing Final Partial inspection for final. Noted on card.
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
08/10/2021 BLDG-Final Inspection 163918-2021 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-Plumbing Final Partial inspection for final. Noted on card.
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
08/12/2021 BLOG-Final Inspection 164061-2021 Partial Pass Tim Kersch
Reinspection Inspection
Passed
Yes
No
No
No
No
Reinspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Re inspection Incomplete
Passed
Yes
No
No
No
No
Relnspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Re inspection Incomplete
Passed
Yes
Yes
Yes
Yes
Yes
Reinspectlon Incomplete
Tuesday, October 26, 2021 Page 34 of 36
Permit Type: BLDG-Associated Permit Residenti: Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed• Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Partial inspection for final. Noted on card. Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
06/30/2021 06/30/2021 BLDG-84 Rough 160897-2021 Partial Pass Tim Kersch Reinspectlon Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency March 4, 2021: (canceled). Yes
Building Deficiencies.
1. Rough combination framing, plumbing,
mechanical, and electrical scope of wofk
not ready -failed.
BLDG-Building Deficiency Rough Combo on units #222,#224, #226, Yes
#228
BLDG~Final Inspection 160896-2021 Partial Pass Tim Kersch Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
07/07/2021 07/07/2021 BLDG-Final Inspection 161317-2021 Partial Pass Tim Kersch Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
07/14/2021 07/14/2021 BLOG-Final Inspection 161830-2021 Partial Pass Tim Kersch Relnspection Incomplete
Checklist !tern COMMENTS Passed
BLDG-Building Deficiency Partial unit's on card Yes
BLDG-Plumbing Final No
BLOG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
07/16/2021 07/16/2021 BLDG-Final Inspection 162069-2021 Partial Pass Tim Kersch Reinspection Incomplete
Tuesday, October 26, 2021 Page 33 of 36
Permit Type: BLDG-Associated Permit Residenti: Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
06/09/2021 06/09/2021 BLDG-84 Rough 159255-2021 Partial Pass Tim Kersch Reinspectlon Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Rough Combo on units #222,#224, #226, Yes
#228
BLDG-Building Deficiency March 4, 2021: (canceled). Yes
Building Deficiencies.
1. Rough combination framing, plumbing,
mechanical, and electrical scope of work
not ready -failed.
06/15/2021 06/15/2021 BLDG-Final Inspection 159629-2021 Cancelled Tim Kersch Reinspectlon Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Final review No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
06/17/2021 06/17/2021 BLOG-Final Inspection 159862-2021 Passed Tim Kersch Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Final review No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final Not ready No
BLOG-Electrical Final No
06/18/2021 06/18/2021 BLDG-Flnal Inspection 160073-2021 Failed Tim Kersch Re inspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
06/28/2021 06/28/2021 BLOG-Final Inspection 160679-2021 Failed Tim Kersch Re inspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
06/29/2021 06/29/2021 BLDG-Final Inspection 160778-2021 Partial Pass Tim Kersch Relnspection Incomplete
Tuesday, October 26, 2021 Page 32 of 36
Permit Type: BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
04/08/2021 04/08/2021 BLDG-Electric Meter 154542-2021 Partial Pass Tim Kersch Reinspection Incomplete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency In progress via email. Yes
04/12/2021 04112/2021 BLDG-23 154 725-2021 Passed Tim Kersch Complete
Gas/Test/Repairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency All test complete. Yes
04114/2021 04/14/2021 BLDG-84 Rough 154835-2021 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial on clubhouse and fitness with new Yes
changes on layout;
Tub traps on (4) units, see card
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
0411912021 0411912021 BLOG-Electrlc Meter 155280-2021 Partial Pass Tim Kersch Reinspection Incomplete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency In progress via email. Yes
0412112021 04/2112021 BLDG-Electric Meter 155598-2021 Partial Pass Tim Kersch Reinspection Incomplete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency In progress via email. Yes
04/28/2021 04128/2021 BLDG-Electric Meter 156145-2021 Partial Pass Paul Burnette Reinspection Incomplete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency In progress via email. Yes
0512012021 05120/2021 BLOG-Final Inspection 157823-2021 Failed Tim Kersch Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLOG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLOG-Electrical Final No
Tuesday, October 26, 2021 Page 31 of 36
Permit Type:
Work Class:
Status:
Scheduled
Date
04/02/2021
04/05/2021
04/06/2021
BLDG-Associated Permit Residenti: Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Apartments Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Actual Inspection Type Inspection No. Inspection Primary Inspector
Start Date Status
Checklist Item COMMENTS
BLDG-Building Deficiency Not ready
04/02/2021 BLDG-Electric Meter
Release
154148-2021 Failed Tim Kersch
Checklist Item COMMENTS
BLDG-Building Deficiency Not ready
04/05/2021 BLDG-84 Rough
Combo(14,24,34,44)
154224-2021 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
Partial on clubhouse and fitness with new
changes on layout;
Tub traps on (4) units, see card
BLDG-Electric Meter
Release
154222-2021 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLDG-Building Deficiency Not ready
BLOG-Gas Meter
Release
154223-2021 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLOG-Building Deficiency Not ready
04/06/2021 BLDG-84 Rough
Combo(14,24,34,44)
154321-2021 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
Rough Combo on units #222,#224, #226,
#228
March 4, 2021: (canceled).
Building Deficiencies.
1. Rough combination framing, plumbing,
mechanical, and electrical scope of work
not ready -failed.
BLOG-Electric Meter
Release
154320-2021 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLDG-Building Deficiency Not ready
Reinspection Inspection
Passed
No
Reinspection Incomplete
Passed
No
Reinspection Incomplete
Passed
No
Yes
Yes
Yes
Yes
Re inspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Yes
Relnspection Incomplete
Passed
Yes
Tuesday, October 26, 2021 Page 30 of 36
Permit Type: BLDG-Associated Permit Residentii Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389
CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-84 Rough 153734-2021 Partial Pass Tim Kersch Relnspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency March 4, 2021: (canceled). Yes
Building Deficiencies.
1. Rough combination framing, plumbing,
mechanical, and electrical scope of work
not ready -failed.
BLDG-Building Deficiency Rough Combo on units #222,#224, #226, Yes
#228
03/30/2021 03/30/2021 BLDG-23 153826-2021 Failed Tim Kersch Reinspection Incomplete
Gas/Test/Repairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
03131/2021 03131/2021 BLDG-82 Drywall, 153909-2021 Partial Pass Tim Kersch Re inspection Incomplete
Exterior Lath, Gas Test,
Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-17 Interior Lath-Drywall Yes
BLDG-18 Exterior Lath and Yes
Drywall
BLDG-23 Gas-Test-Repairs Yes
04101/2021 04/01/2021 BLDG-81 Underground 154047-2021 Failed Chris Renfro Re inspection Incomplete
Combo(11, 12,21,31)
Checklist ttem COMMENTS Passed
BLDG-Building Deficiency Not ready No
BLDG-11 Foundation-Ftg-Piers No
(Rebar)
BLDG-12 Steel-Bond Beam No
BLDG-21 No
U nde rg round-Underfloor
Plumbing
BLDG-31 No
Underground-Conduit Wiring
BLDG-Electric Meter 154049-2021 Failed Chris Renfro Reinspection Incomplete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
BLDG-Gas Meter 154048-2021 Failed Chris Renfro Reinspection Incomplete
Release
Tuesday, October 26, 2021 Page 29 of 36
',;\1,,q,),~',t/V, 'i,.1,;;"•1 %ft'1''"';';J;', 1 , 1)),,, ,, • ',,)ct.', 1 ' -, , , ·:~:·:·e,ilb:r IN$PECTIQf11 HiS'f'ORYi,(or (CBQ2020-0070)
Permit Type: BLDG-Associated Permit Residenti, Application Date: 01/2212020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/1912020 Subdivision:
Status: Closed -Ftnaled Expiration Date: 1212712021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG➔Building Deficiency No
03125/2021 0312512021 BLOG-17 Interior 153536-2021 Partial Pass Tim Kersch Reinspectlon Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLOG-Building Deficiency March 4, 2021: (virtual inspection). Yes
No Building deficiencies.
1. Drywall type and drywall nailing pattern
scope of work, units #422 through units
#429-approved.
BLDG-Building Deficiency Exterior lath inspection on South East Yes
elevation. Rough frame partial on drops
only.
BLDG-23 153449-2021 Failed Tim Kersch Reinspection Incomplete
GasfTesURepairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLOG-Electric Meter 153539-2021 Failed Tim Kersch Re inspection Incomplete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Gas Meter 153538-2021 Failed Tim Kersch Reinspection Incomplete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
03126/2021 03126/2021 BLDG-17 Interior 153637-2021 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Exterior lath inspection on South East Yes
elevation. Rough frame partial on drops
only.
BLDG~Building Deficiency March 4, 2021· (virtual inspection). Yes
No Building deficiencies.
1. Drywall type and drywall nailing pattern
scope of work, units #422 through units
#429-approved.
03129/2021 03129/2021 BLDG-17 Interior 153735-2021 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG4 Building Deficiency Yes
Tuesday, October 26, 2021 Page 28 of 36
j\•)\, fp,.H;{' h ,' ' ~, \ '
111: •1 ·~:.~ •. ~i:1.i1:tt1JltJNSP~ci.ior,1 HXSTORY f~~: cqQ2020-0010)
Permit Type: BLDG-Associated Permit Residenti,
Work Class: Apartments
Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Status'.
Scheduled
Date
0311612021
03/1712021
03122/2021
Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
0311612021 BLDG-84 Rough
Combo(14,24,34,44)
152764-2021 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
March 4, 2021: (canceled).
Building Deficiencies.
1. Rough combination framing, plumbing,
mechanical, and electrical scope of work
not ready-failed.
Rough Combo on units #222,#224, #226,
#228
03117/2021 BLDG-17 Interior
Lath/Drywall
152922-2021 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
March 4, 2021: (virtual inspection).
No Building deficiencies.
1. Drywall type and drywall nailing pattern
scope of work, units #422 through units
#429-approved.
Exterior lath inspection on South East
elevation. Rough frame partial on drops
only.
BLDG-84 Rough
Combo(14,24,34,44)
152923-2021 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
Rough Combo on units #222,#224, #226,
#228
March 4, 2021: (canceled).
Building Deficiencies.
1. Rough combination framing, plumbing,
mechanical, and electrical scope of work
not ready -failed.
03122/2021 BLDG-17 Interior
Lath/Drywall
153196-2021 Partial Pass Paul Burnette
Checklist Item
BLDG-Building Deficiency
BLOG-Building Deficiency
COMMENTS
Exterior lath inspection on South East
elevation. Rough frame partial on drops
only.
March 4, 2021: (virtual inspection).
No Building deficiencies.
1. Drywall type and drywall nailing pattern
scope of work, units #422 through units
#429-approved.
BLDG-23
Gas/Test/Repairs
153195-2021 Paul Burnette
Reinspection Inspection
Relnspection Incomplete
Passed
Yes
Yes
Reinspection Incomplete
Passed
Yes
Yes
Reinspection Incomplete
Passed
Yes
Yes
Reinspection Incomplete
Passed
Yes
Yes
Reinspection Incomplete
Tuesday, October 26, 2021 Page 27 of 36
Permit Type: BLDG-Associated Permit Residenti: Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
Scheduled
Date
03/09/2021
03/11/2021
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
03/09/2021
03/11/2021
BLDG-84 Rough
Combo(14,24,34,44)
151980-2021 Failed Tony Alvarado
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
March 4, 2021: (canceled).
Building Deficiencies.
1. Rough combination framing, plumbing,
mechanical, and electrical scope of work
not ready -failed.
Rough Combo on units #222,#224, #226,
#228
BLDG-84 Rough 152241-2021 Partial Pass Chris Renfro
Combo(14,24,34,44)
Checklist Item COMMENTS
BLDG-Building Deficiency Partial on clubhouse and fitness with new
changes on layout;
Tub traps on (4) units, see card
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
BLDG~17 Interior 152530-2021 Partial Pass Tim Kersch
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
March 4, 2021: (virtual inspection).
No Building deficiencies.
1. Drywall type and drywall nailing pattern
scope of work, units #422 through units
#429-approved.
Exterior lath inspection on South East
elevation. Rough frame partial on drops
only.
BLDG-84 Rough
Combo(14,24,34,44)
152529-2021 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
Rough Combo on units #222,#224, #226,
#228
March 4, 2021: (canceled).
Building Deficiencies.
1. Rough combination framing, plumbing,
mechanical, and electrical scope of work
not ready -failed.
Tuesday, October 26, 2021
Reinspection Inspection
Reinspection Incomplete
Passed
No
Yes
Reinspection Incomplete
Passed
No
Yes
Yes
Yes
Yes
Re inspection Incomplete
Passed
Yes
Yes
Reinspectlon Incomplete
Passed
Yes
Yes
Page 26 of 36
Permit Type:
Work Class:
Status:
Scheduled
Date
02/26/2021
03/02/2021
03/03/2021
03/04/2021
BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Apartments Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Actual
Start Date
Inspection Type Inspection No. Inspection Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
Status
COMMENTS
Rough Combo on units #222,#224, #226,
#228
02/26/2021 BLDG-84 Rough
Combo(14,24,34,44)
151532-2021 Partial Pass Tim Kersch
03/02/2021
03/03/2021
03/04/2021
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS
BLOG-17 Interior 151710-2021 Partial Pass Tim Kersch
Lath/Drywa 11
Checklist Item COMMENTS
BLDG-Building Deficiency Exterior lath inspection on South East
elevation. Rough frame partial on drops
only.
BLDG-14 151874-2021 Partial Pass Tim Kersch
Frame/Steel/Bolting/We
lding (Decks}
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-17 Interior 151979-2021 Partial Pass Tony Alvarado
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
March 4, 2021: (virtual inspection).
No Building deficiencies.
1. Drywall type and drywall nailing pattern
scope of work, units #422 through units
#429-approved.
Exterior lath inspection on South East
elevation. Rough frame partial on drops
only.
Reinspection
Passed
Yes
Yes
Yes
Yes
Yes
Relnspection
Passed
Yes
Yes
Yes
Yes
Yes
Reinspection
Passed
Yes
Inspection
Incomplete
Incomplete
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Yes
Tuesday, October 26, 2021 Page 25 of 36
"'"✓" • , <r', "-',,~2;,, ,.,,,v, ,
i·,, ,,,., PERMIT IN§ ~l{;:TION,H STORY.for (CBRA2020-0~~0)
Permit Type: BLDG-Associated Permit Residenti,
Work Class: Apartments
Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Issue Date: 05/19/2020 Subdivision:
Status:
Scheduled
Date
02/19/2021
02/23/2021
02/24/2021
02/25/2021
Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008 IVR Number: 24389
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
Status
02/19/2021
02/23/2021
02/24/2021
02/25/2021
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Jason Pasiut
COMMENTS Passed
Not ready Yes
TEXT Created Date
Top-out complete for segment 1, floor 1 units 11/05/2020
203 -210 -SEE CORRECTION NOTICE DATI
11/5/2020
BLDG-84 Rough 150872-2021 Partial Pass Tim Kersch Reinspection
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
BLOG-17 Interior 151182-2021 Partial Pass Tim Kersch Re inspection
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Exterior lath Inspection on South East Yes
elevation. Rough frame partial on drops
only.
Incomplete
Incomplete
BLDG-14 151309-2021 Partial Pass Tim Kersch Reinspection Incomplete
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-17 Interior 151308-2021 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Exterior lath inspection on South East Yes
elevation. Rough frame partial on drops
only.
BLDG-84 Rough 151440-2021 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Tuesday, October 26, 2021 Page 24 of 36
Permit Type: BLDG-Associated Permit Residenti,
Work Class: Apartments
Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Issue Date: 05/19/2020 Subdivision:
Status:
Scheduled
Date
02/11/2021
02/16/2021
02/17/2021
Closed -Finaled Expiration Date: 12/27/2021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
02/11/2021
02/16/2021
02/17/2021
Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency
NOTES Created By
Jason Pasiut
Not ready No
TEXT Created Date
Top-out complete for segment 1, floor 1 units 11/05/2020
203-210-SEE CORRECTION NOTICE DAT[
11/5/2020
BLDG-84 Rough 150227-2021 Partial Pass Chris Renfro Reinspection
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Rough Combo on units #222,#224, #226, Yes
#228
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
BLDG-17 Interior 150332-2021 Partial Pass Chris Renfro Re inspection
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Exterior lath inspection on South East Yes
elevation. Rough frame partial on drops
only.
BLDG-24 Rough/Topout 150331-2021 Failed Chris Renfro Reinspectlon
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
NOTES Created By TEXT Created Date
Jason Pasiut Top-out complete for segment 1, floor 1 units 11/05/2020
203 -210 -SEE CORRECTION NOTICE DAT!
11/5/2020
BLDG-Final Inspection 150612-2021 Partial Pass Tim Kersch Reinspectlon
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
BLDG-24 Rough/Topout 150728-2021 Partial Pass Tim Kersch Reinspection
Incomplete
Incomplete
Incomplete
Incomplete
Incomplete
Tuesday, October 26, 2021 Page 23 of 36
f>;/\;A,, a '/4\,,, 0 / "(,\' '"'
' _ , 1,011/'. • PERMIT IN$ftl;CTi'QtJ;J;t,ISTOR¥:for (CB-2020-0070)
Permit Type: BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No, Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
02/01/2021 02/01/2021 BLDG-17 Interior 149547-2021 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/02/2021 02/02/2021 BLDG-84 Rough 149614-2021 Partial Pass Tim Kersch Re inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
02/04/2021 02/04/2021 BLDG-14 149828-2021 Partial Pass Tim Kersch Reinspection Incomplete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/05/2021 02/05/2021 BLDG-17 Interior 149962-2021 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/08/2021 02/08/2021 BLDG-24 RoughfTopout 14997 4-2021 Partial Pass Chris Renfro Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See card for areas inspected rough top out Yes
of D1/N in stacks #432 through #437
NOTES Created By TEXT Created Date
Jason Pasiut Top-out complete for segment 1, floor 1 units 11/05/2020
203 -210 -SEE CORRECTION NOTICE DATI
11/5/2020
02/10/2021 02/10/2021 BLDG-17 Interior 150226-2021 Partial Pass Chris Renfro Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Drywall first layer at stairways #3 & #4 , Yes
drywall on Corridor's section #2 on 2nd
and 3rd floor
BLDG-24 Rough/Topout 150225-2021 Failed Chris Renfro Reinspection Incomplete
Tuesday, October 26, 2021 Page 22 of 36
Permit Type: BLDG-Associated Permit Residenti: Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status -~,-··----
01/26/2021 01/26/2021 BLDG-84 Rough 149188-2021 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
01/28/2021 01/28/2021 BLDG-14 149309-2021 Partial Pass Tim Kersch Reinspection Incomplete
Frame/Steel!Boltlng/We
!ding (Decks)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Yes
BLDG-17 Interior 149310-2021 Partial Pass Tim Kersch Re inspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 149308-2021 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
01/29/2021 01129/2021 BLDG-84 Rough 149495-2021 Partial Pass Tim Kersch Re Inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
Tuesday, October 26, 2021 Page 21 of 36
" 'rJ},,' ,, \ J/ V0 s ~' %/ ,1, ' ' ; ' r
i ,,:,,C , , ,, _ ,~'ERMIT JNSPE(;;TJON HlSTORY fq,i; ~ 2Q20-0070)
Permit Type:
Work Class:
Status:
Scheduled
Date
01/20/2021
01/21/2021
01/25/2021
BLDG-Associated Perm it Residenti; Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Apartments Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
Actual
Start Date
01/20/2021
01/21/2021
01/25/2021
IVR Number: 24389 CARLSBAD, CA 92008
Inspection Type Inspection No. Inspection Primary Inspector Reinspection
Status
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLOG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
BLDG-14 148732-2021 Partlal Pass Tim Kersch Reinspection
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLOG-16 Insulation 148733-2021 Partial Pass Tim Kersch Reinspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 148824-2021 Partial Pass Tim Kersch Re inspection
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-24 Rough/Topout 148975-2021 Partial Pass Tim Kersch Reinspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase one floor one complete. Yes
Details for partial inspection on plans.
NOTES Created By
Jason Pasiut
TEXT Created Date
Top-out complete for segment 1, floor 1 units 11/05/2020
203 -210-SEE CORRECTION NOTICE DAT!
11/5/2020
Inspection
Incomplete
Incomplete
Incomplete
Incomplete
BLDG-84 Rough
Combo(14,24,34,44)
148974-2021 Partial Pass Tim Kersch Reinspection Incomplete
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
COMMENTS Passed
Yes
Yes
Yes
Yes
Yes
Tuesday, October 26, 2021 Pago 20 of 36
¥ S';/ • ~ 1 • tw ' , ' fi , s " ~ t t--~-IT INSPECTION HIST~RY fpr-{CB 2Q20-0070)
Permit Type: BLDG-Associated Permit Residenti: Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase one floor one complete. Yes
Details for partial inspection on plans.
NOTES Created By TEXT Created Date
Jason Pasiut Top-out complete for segment 1, floor 1 units 11/05/2020
203-210-SEE CORRECTION NOTICE DATI
11/5/2020
01/12/2021 01/12/2021 BLDG-14 148116-2021 Partial Pass Tim Kersch Reinspection Incomplete
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/1312021 01113/2021 BLDG-14 148213-2021 Partial Pass Tim Kersch Re inspection Incomplete
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-24 Rough/Topout 148168-2021 Partial Pass Tim Kersch Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase one floor one complete. Yes
Details for partial inspection on plans.
NOTES Created By TEXT Created Date
Jason Pasiut Top-out complete for segment 1, floor 1 units 11/0512020
203 -210-SEE CORRECTION NOTICE DATI
111512020
01/1912021 01119/2021 BLDG-15 Roof/ReRoof 148528-2021 Partial Pass Tim Kersch Relnspectlon Incomplete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Segment two. Yes
BLDG-17 Interior 148527-2021 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 148530-2021 Partial Pass Tim Kersch Relnspection Incomplete
Combo(14,24,34,44)
Tuesday, October 26, 2021 Page 19 of 36
irhtt;,sJ '; , '; eoje ,;,!0'.'t;j): ; ' ' , 1)if" 1
;,:,,, .. ·" ~;;~: ;· ·, 1l41J.~N~~ecr~oN t:t,$TQR, for1 ~t . ~020::-0970) ,
Permit Type: BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date-: 05/19/2020 Subdivision:
Status· Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
01/05/2021 01/05/2021 BLDG-13 Shear 147413-2021 Partial Pass Tim Kersch Relnspection Incomplete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-84 Rough 147414-2021 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLOG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
01/08/2021 01/08/2021 BLDG-84 Rough 147845-2021 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
01/11/2021 01/11/2021 BLDG-14 147962-2021 Partial Pass Tim Kersch Reinspection Incomplete
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-24 Rough/Topout 147963-2021 Partial Pass Tim Kersch Relnspectlon Incomplete
Tuesday, October 26, 2021 Page 18 of 36
~+;., {,e ~';k' • '
':, , PSJ'!MI'f INSPECTION H~STORY for (CBRA2020·0070)
Permit Type: BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Worl: Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Ctiecklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
12/18/2020 12/18/2020 BLDG-24 Rough/Topout 146654-2020 Partial Pass Tim Kersch Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase one floor one complete. Yes
Details for partial inspection on plans.
NOTES Created By TEXT Created Date
Jason Pasiut Top-out complete for segment 1, floor 1 units 11/05/2020
203-210-SEE CORRECTION NOTICE DATI
11/5/2020
BLDG-84 Rough 146655-2020 Partial Pass Tim Kersch Re inspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
12/22/2020 12/22/2020 BLDG-14 146793-2020 Partlal Pass Tim Kersch Reinspection Incomplete
Frame/Steel/Bolting/We
lding (Decks)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Yes
12/24/2020 12/24/2020 BLDG-14 146962-2020 Partial Pass Tim Kersch Reinspection Incomplete
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/28/2020 12/28/2020 BLDG-84 Rough 147015-2020 Cancelled Tim Kersch Reinspectlon Incomplete
Combo(14,24,34,44)
Tuesday, October 26, 2021 Page 17 of 36
Permit Type: BLDG-Associated Permit Residenti: Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
12/10/2020 12/10/2020 BLDG-15 Roof/ReRoof 145953-2020 Partial Pass Tim Kersch Reinspection Incomplete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Segment two. Yes
12/11/2020 12/11/2020 BLDG-24 Rough/Topout 146079-2020 Partial Pass Tim Kersch Relnspectlon Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase one floor one complete. Yes
Details for partial inspection on plans.
NOTES Created By TEXT Created Date
Jason Pasiut Top-out complete for segment 1, floor 1 units 11/05/2020
203 -210 -SEE CORRECTION NOTICE DATI
11/5/2020
12/14/2020 12/14/2020 BLOG-84 Rough 146205-2020 Passed Tim Kersch Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial on plans_ Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
12/15/2020 12/15/2020 BLDG-17 Interior 146223-2020 Partial Pass Tim Kersch Reinspection Incomplete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/16/2020 12/16/2020 BLDG-84 Rough 146342-2020 Partial Pass Tim Kersch Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLOG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
12/17/2020 12/17/2020 BLOG-84 Rough 146521-2020 Partial Pass Tim Kersch Reinspectlon Incomplete
Combo(14,24,34,44)
Tuesday, October 26, 2021 Page 16 of 36
Permit Type:
Work Class:
Status:
Scheduled
Date
12103/2020
12107/2020
BLDG-Associated Permit Residenti; Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Apartments Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
24389 CARLSBAD, CA 92008
Actual
Start Date
IVR Number:
Inspection Type Inspection No. Inspection Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
Status
COMMENTS
7/16/20, cancelled per contractor
Underground parking slab on grade at Line
1-8 & A 1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wall.
8/14/20, ramp slab on grade, Line B-E &
11-14
Last of podium deck
8/13/20, not ready.
7/17/20, GB-3 & spread footings at Line 9
&D.
See plans. Partial pass on foundation walls
12103/2020 BLDG-14 145314-2020 Partial Pass Tim Kersch
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Jason Pasiut
COMMENTS
Shear at north corner.
Noted in detail on card.
TEXT
Floor sheathing inspection of segment 2, level
4 south end ok.
BLDG-24 Rough/Topout 145298-2020 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Jason Pasiut
COMMENTS
Phase one floor one complete.
Details for partial inspection on plans.
TEXT
Top-out complete for segment 1, floor 1 units
203-210-SEE CORRECTION NOTICE DATI
11/5/2020
12107/2020 BLDG-14 145569-2020 Passed Tim Kersch
Frame/SteellBoltlngNVe
ldlng (Decks)
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Jason Pasiut
COMMENTS
Shear at north corner.
Noted in detail on card.
TEXT
Floor sheathing inspection of segment 2, level
4 south end ok.
Reinspection
Passed
No
Yes
Yes
No
Yes
Yes
Inspection
Reinspection Incomplete
Passed
Yes
Created Date
11/05/2020
Reinspection Incomplete
Passed
Yes
Created Date
11/05/2020
Passed
Yes
Created Date
11/05/2020
Complete
Tuesday, October 26, 2021 Page 15 of 36
Permit Type:
Work Class:
Status:
Scheduled
Date
11/2512020
1210112020
1210212020
BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Apartments Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Actual Inspection Type
Start Date
Inspection No. Inspection Primary Inspector Reinspection Inspection
NOTES Created By
Jason Pasiut
Status
TEXT Created Date
Floor sheathing inspection of segment 2, level 11/05/2020
4 south end ok.
11125/2020 BLDG-14 144806-2020 Partial Pass Tim Kersch Reinspection
12101/2020
1210212020
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Jason Pasiut
COMMENTS
TEXT
Floor sheathing inspection of segment 2, level
4 south end ok.
BLDG-16 lnsulatlon
Checklist Item
144805-2020
COMMENTS
Partial Pass Tim Kersch
BLDG-Building Deficiency
BLDG-24 Rough/Topout 144804-2020 Partial Pass Tim Kersch
Checklist Item COMMENTS
Phase one floor one complete.
Passed
Yes
Created Date
11/05/2020
Reinspectlon
Passed
Yes
Reinspectlon
Passed
Yes BLDG-Building Deficiency
NOTES Created By
Jason Pasiut
TEXT Created Date
Top-out complete for segment 1, floor 1 units 11/05/2020
203 -210 • SEE CORRECTION NOTICE DATI
1115/2020
BLDG-14 144958-2020 Partial Pass Tim Kersch Reinspection
Frame/Steel/Bolting/We
ldlng (Decks)
Ct1ecklist Item COMMENTS Passed
BLDG-Building Deficiency Shear at north corner. Yes
NOTES Created By TEXT Created Date
Jason Pasiut Floor sheathing inspection of segment 2, level 11/05/2020
4 south end ok.
BLDG-11 145183-2020 Partial Pass Tim Kersch Reinspection
Foundatlon/Ftg/Plers
(Rebar)
Incomplete
Incomplete
Incomplete
Incomplete
Incomplete
Tuesday, October 26, 2021 Page 14 of 36
Permit Type:
Work Class:
Status:
Scheduled
Date
BLDG-Associated Permit Residenti,
Apartments
Closed -Finaled
Actual Inspection Type
Start Date
Application Date:
Issue Date:
Expiration Date:
IVR Number:
Inspection No.
01/22/2020
05/19/2020
12/27/2021
24389
Inspection
Status
Owner: CARLSBAD VILLAGE PARTNERS LP
Subdivision:
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
Primary Inspector Reinspection Inspection
·---------------------------------------------
1111812020
11/1912020
11120/2020
1112312020
NOTES Created By
Jason Pasiut
TEXT
Floor sheathing inspection of segment 2, level
4 south end ok.
11118/2020 BLOG-24 Rough/Topout 143976-2020 Partial Pass Tim Kersch
11119/2020
1112012020
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Jason Pasiut
COMMENTS
Phase one floor one complete.
TEXT
Top-out complete for segment 1, floor 1 units
203 -210 -SEE CORRECTION NOTICE DATI
111512020
BLDG-11 144204-2020 Partial Pass Tim Kersch
Foundation/Ftg/Plers
(Rebar)
Checklist Item COMMENTS
BLDG-Building Deficiency 7/17/20, GB-3 & spread footings at Line 9
&D.
BLDG-Building Deficiency See plans. Partial pass on foundation walls
BLDG-Building Deficiency 7/16/20, cancelled per contractor
BLDG-Building Deficiency Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2walL
BLDG-Building Deficiency 8/14/20, ramp slab on grade, Line 8-E &
11-14
Last of podium deck
BLDG-Building Deficiency 8/13/20, not ready.
BLDG-24 Rough/Topout 144362-2020 Partial Pass Tim Kersch
Checklist Item
BLDG-Building Deficiency
NOTES Created By
Jason Pasiut
COMMENTS
Phase one floor one complete.
TEXT
Top-out complete for segment 1, floor 1 units
203 • 210 -SEE CORRECTION NOTICE DATI
1115/2020
11/2312020 BLOG-14 144472-2020 Partial Pass Tim Kersch
Frame/Steel/Boltlng!We
!ding (Decks)
Checklist !tern
BLDG-Building Deficiency
COMMENTS
Tuesday, October 26, 2021
Created Date
11/0512020
Reinspection Incomplete
Passed
Yes
Created Date
11/0512020
Reinspection Incomplete
Passed
Yes
Yes
No
Yes
Yes
No
Reinspection Incomplete
Passed
Yes
Created Date
11/0512020
Reinspection Incomplete
Passed
Yes
Page 13 of 36
Permit Type:
Work Class:
Status:
Scheduled
Date
11/09/2020
11/10/2020
11/13/2020
BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Apartments Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
11/09/2020
11/10/2020
11/13/2020
NOTES Created By
Jason Pasiut
TEXT
Top-out complete for segment 1, floor 1 units
203-210-SEE CORRECTION NOTICE DAT!
11/5/2020
BLDG-14 143371-2020 Partial Pass Tim Kersch
Frame/Steel/Bolting/We
iding (Decks)
Checklist Item COMMENTS
BLDG-Building Deficiency
NOTES Created By TEXT
Jason Pasiut Floor sheathing inspection of segment 2, level
4 south end ok.
BLDG-11 143488-2020 Partial Pass Tim Kersch
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS
BLDG-Building Deficiency See plans. Partial pass on foundation walls
BLDG-Building Deficiency 7/16/20, cancelled per contractor
BLDG-Building Deficiency Underground parking slab on grade at Line
1-8 & A1-AB, need deputy inspector report
for continuous deepened edge steel along
W2wal1.
BLDG-Building Deficiency 7/17/20, GB-3 & spread footings at Line 9
&D.
BLDG-Building Deficiency 8/13/20, not ready.
BLOG-Building Deficiency 8/14/20, ramp slab on grade, Line 8-E &
11-14
BLDG-24 RoughfTopout 143487-2020 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLOG-Building Deficiency Phase one floor one complete.
NOTES Created By TEXT
Jason Pasiut Top-out complete for segment 1, floor 1 units
203-210 -SEE CORRECTION NOTICE DATI
11/5/2020
BLDG-14 143629-2020 Partial Pass Tim Kersch
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item COMMENTS
BLDG-Building Deficiency
Reinspection Inspection
Created Date
11/05/2020
Reinspection
Passed
Yes
Created Date
11/05/2020
Reinspection
Passed
Yes
No
Yes
Yes
No
Yes
Reinspectlon
Passed
Yes
Created Date
11/05/2020
Remspection
Passed
Yes
Incomplete
Incomplete
Incomplete
Incomplete
Tuesday, October 26, 2021 Page 12 of 36
t ,, ' ' j; '} ) ' "
·. . , ~ERMIT INSPE~TION HISTORY Jo~ ICBR.42Q20-0010}
Permit Type:
Work Class:
Status:
Scheduled
Date
10/28/2020
10/30/2020
11/02/2020
11/05/2020
BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Apartments Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
Actual
Start Date
10/28/2020
10/30/2020
11/02/2020
11/05/2020
IVR Number: 24389 CARLSBAD, CA 92008
Inspection Type Inspection No. Inspection Primary Inspector
Status
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-16 Insulation 142203-2020 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-14 142637-2020 Partial Pass Tim Kersch
Frame/Steel/Bolting/We
ldlng (Decks)
Cl1ecklist ltem COMMENTS
BLDG-Building Deficiency
BLDG-24 Rough/Topout 142724-2020 Partial Pass Tim Kersch
Checklist Item COMMENTS
BLDG-Building Deficiency Phase one floor one complete.
BLDG-11 143092-2020 Cancelled Jason Paslut
Fou n datlon/Ftg/P le rs
(Rebar)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLOG-Building Deficiency
BLDG-Building Deficiency
BLOG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
See plans. Partial pass on foundation walls
7/16/20, cancelled P,er contractor
8/13/20, not ready.
7/17/20, GB-3 & spread footings at Line 9
&D.
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2 wall.
8/14/20, ramp slab on grade, Line B-E &
11-14
BLDG-14
Frame/Steel/Bolting/We
lding (Decks)
143093-2020 Partial Pass Jason Paslut
Checklist Item
BLOG-Building Deficiency
NOTES Created By
Jason Pasiut
COMMENTS
TEXT
Floor sheathing inspection of segment 2, level
4 south end ok.
BLDG-24 Rough/Topout 143091-2020 Partial Pass Jason Paslut
Checklist Item COMMENTS
BLDG-Building Deficiency Phase one floor one complete.
Reinspection
Passed
Yes
Reinspection
Passed
Yes
Reinspection
Passed
Yes
Relnspection
Passed
Yes
Reinspection
Passed
Yes
No
No
Yes
Yes
Yes
Inspection
Incomplete
Incomplete
Incomplete
Incomplete
Reinspection Incomplete
Passed
Yes
Created Date
11/05/2020
Reinspection Incomplete
Passed
Yes
Tuesday, October 26, 2021 Page 11 of 36
~s , 0' \ t>, -, 1, , 4 ,11 ,
,-,, ~1• ,I: PErfMIT 11\(S~,~C:{ION 11tlTORY,f,or,, <iBM2020-0070}
Permit Type: BLOG-Associated Permit Residenti;
Work Class: Apartments
Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Status:
Scheduled
Date
10/14/2020
10/19/2020
10/20/2020
10/26/2020
Issue Date-: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
Actual Inspection Type Inspection No. Inspection
Status
Primary Inspector
Start Date
10/1412020
10/16/2020
10/20/2020
10/26/2020
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
7/16/20, cancelled per contractor
8/14/20, ramp slab on grade, Line B-E &
11-14
See plans. Partial pass on foundation walls
8/13/20, not ready.
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wa11.
7/17/20, GB-3 & spread footings at Line 9
& D.
BLDG-14 140773-2020 Passed Tim Kersch
Frame/Steel/Bolting/We
!ding (Decks)
Checklist Item COMMENTS
BLOG-Building Deficiency
BLDG-11 141165-2020 Partial Pass Tim Kersch
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS
BLDG-Building Deficiency 8/13/20, not ready.
BLDG-Building Deficiency Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wall.
BLDG-Building Deficiency 8/14/20, ramp slab on grade, Line B-E &
11-14
BLDG-Building Deficiency 7/16/20, cancelled per contractor
BLDG-Building Deficiency See plans. Partial pass on foundation walls
BLDG-Building Deficiency 7/17/20, GB-3 & spread footings at Line 9
& D.
BLDG-12 Steel/Bond 141399-2020 Partial Pass Tim Kersch
Beam
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-14 141400-2020 Partial Pass Tim Kersch
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist ltern COMMENTS
BLDG-Building Deficiency
BLDG-14 142005-2020 Partlal Pass Tim Kersch
Frame/Steel/Bolting/We
ldlng (Decks)
Reinspection Inspection
Passed
No
Yes
Yes
No
Yes
Yes
Passed
Yes
Complete
Reinspection Incomplete
Passed
No
Yes
Yes
No
Yes
Yes
Reinspection
Passed
Yes
Relnspection
Passed
Yes
Reinspection
Incomplete
Incomplete
Incomplete
Tuesday, October 26, 2021 Page 10 of 36
Permit Type:
Work Class:
Status:
Scheduled
Date
09/2212020
09/23/2020
10/0212020
BLDG-Associated Permit Residenlii Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Apartments Issue Date: 05/1912020 Subdivision:
Closed -Finaled Expiration Date: 1212712021 Address: 1040 CARLSBAD VILLAGE DR
Actual
Start Date
09/2212020
09/23/2020
10/0212020
IVR Number: 24389 CARLSBAD, CA 92008
Inspection Type Inspection No. Inspection Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
Status
COMMENTS
7/16/20, cancelled per contractor
7/17/20, GB-3 & spread footings at Line 9
&D.
8/14/20, ramp slab on grade, Line B-E &
11-14
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2. wall.
8/13/20, not ready.
See plans. Partial pass on foundation walls
BLDG-14 138902-2020 Partial Pass Tim Kersch
Frame/Steel/Bolting/We
!ding (Docks)
Checklist Item COMMENTS
BLDG-Building Deficiency
BLDG-11 139021-2020 Partial Pass Paul Burnette
Foundation/Ftg/Piers
(Robar)
Checklist Item COMMENTS
BLDG-Building Deficiency See plans. Partial pass on foundation walls
BLOG-Building Deficiency 7/17/20, GB-3 & spread footings at Une 9
&D.
BLDG-Building Deficiency 8/14/20, ramp slab on grade, Line B-E &
11-14
BLDG-Building Deficiency 8/13/20, not ready.
BLDG-Building Deficiency 7/16/20, cancelled per contractor
BLDG-Building Deficiency Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wall.
BLDG-11 139897-2020 Partial Pass Tim Kersch
F OU n datio n/Ftg/Plers
(Robar)
Reinspection
Passed
No
Yes
Yes
Yes
No
Yes
Inspection
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Yes
Yes
No
No
Yes
Reinspection Incomplete
Tuesday, October 26, 2021 Page 9 of 36
fi f , :,•J :):\{ 0\i0a ,"'''' ,, "' {{%\ h {,, r 4' , " ,,
*' ' -1 ' ,, RERMtr'. IN§PiJ;"FIPN HI$,TO;~Y for ((;~ffP-2020:-0070)
Permit Type: BLDG-Associated Permit Residenti,
Work Class: Apartments
Application Date: 0112212020 Owner: CARLSBAD VILLAGE PARTNERS LP
Status:
Scheduled
Date
08114/2020
08/17/2020
08/20/2020
08/25/2020
09/10/2020
Issue Date: 05119/2020 Subdivision:
Closed -Finaled Expiration Date: 1212712021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
8/13/20, sanitary waste, Line A-D.5 &
14-15 only.
Underground waste lines for segment one
to sump pump only. OK to backfill
Segment 2 waste to sump pump, Line 9-14
& F.5
08/14/2020 BLDG-11 135699-2020 Partial Pass Michael Collins
08/17/2020
08/20/2020
08/25/2020
09/10/2020
F ou n datlon/Ftg/P le rs
(Robar)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
See plans. Partial pass on foundation walls
7/17/20, GB-3 & spread footings at Line 9
&D.
7/16/20, cancelled per contractor
8/13/20, not ready.
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wall.
8/14/20, ramp slab on grade, Line B-E &
11-14
BLDG-14 135801-2020 Partial Pass Paul Burnette
Frame/Steel/Bolting/We
lding (Docks)
Checklist ltern COMMENTS
BLDG-Building Deficiency
BLDG-21 136213-2020 Partial Pass Chris Renfro
U nderg rou nd/U ndertlo
or Plumbing
Checklist Item COMMENTS
BLDG-Building Deficiency Underground waste and maintain into
sewer , in front segment
BLDG-12 Steel/Bond 136485-2020 Partial Pass Paul Burnette
Beam
Checklist Item COMMENTS
BLDG•Building Deficiency
BLDG-11 137860-2020 Partial Pass Paul Burnette
Foundatlon/Ftg/Piers
(Rebar)
Reinspection Inspection
Passed
Yes
Yes
Yes
Reinspection Incomplete
Passed
Yes
Yes
No
No
Yes
Yes
Reinspectlon
Passed
Yes
Reinspection
Passed
Yes
Reinspectlon
Passed
Yes
Re inspection
Incomplete
Incomplete
Incomplete
Incomplete
Tuesday, October 26, 2021 Page 8 of 36
' J' ' •' ' !:;: ; -S; \ ; \ \ ",' , ' ! ' \ )
. -. Pf;:RMIT.INSPEtTION HISTORY for (CB1!A2020-0070)
Permit Type:
Work Class:
Status:
Scheduled
Date
0810612020
08111/2020
08113/2020
BLDG-Associated Permit Residenti; Application Date: 0112212020 Owner: CARLSBAD VILLAGE PARTNERS LP
Apartments Issue Date: 0511912020 Subdivision:
Closed -Finaled Expiration Date: 1212712021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD. CA 92008
Actual Inspection Type Inspection No. Inspection Primary Inspector
Start Date Status
08106/2020 BLDG-11 134888-2020 Partial Pass Paul Burnette
Foundation/Ftg/Piers
(Rebar)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
7/17/20, GB-3 & spread footings at Line 9
& D.
See plans. Partial pass on foundation walls
7/16/20, cancelled per contractor
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wall.
08111/2020 BLDG-11 135340-2020 Partial Pass Paul Burnette
F ou n dation/Ftg/P le rs
(Rebar)
Checklist Item
BLDG-Building Deficiency
BLOG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
See plans. Partial pass on foundation walls
Underground parking slab on grade at Line
1-8 & A1-AB, need deputy inspector report
for continuous deepened edge steel along
W2 wall.
7/16/20, cancelled per contractor
7/17/20, GB-3 & spread footings at Line 9
&D.
08113/2020 BLDG-11 135612-2020 Failed Michael Collins
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item
BLDG•Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
8/13/20, not ready.
See plans. Partial pass on foundation walls
7/17/20, GB-3 & spread footings at Line 9
&D.
7/16/20, cancelled per contractor
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wall.
BLDG-21
Underground/Undertlo
or Plumbing
135561-2020 Partial Pass Michael Collins
Reinspection Inspection
Reinspection Incomplete
Passed
Yes
Yes
No
Yes
Reinspection Incomplete
Passed
Yes
Yes
No
Yes
Reinspectlon Incomplete
Passed
No
Yes
Yes
No
Yes
Reinspection Incomplete
Tuesday, October 26, 2021 Page 7 of 36
, I j "• f')}' 1\}~,'ih!fi, ', ,It I '1 ,,~jl i \ f1, ,'-:,, ,")/ ' \ l ,'1 '• •, ';;; I 'n ,;l
.'·ft', ;i·. ,. ·eeRMl'f:I se·ec~ 'ON; W:STQR~,f.Qn: cali•20:001oj
Permit Type: BLOG-Associated Permit Residenti.
Work Class: Apartments
Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Status:
Scheduled
Date
07/28/2020
07/30/2020
08/0312020
Issue Date: 05/19/2020 Subdivision:
Closed -Finaled Expiration Date: 12/27/2021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD. CA 92008
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
Cancelled per contractor
See plans. Partial pass. (4) F4 column
footings.
BLDG-14
Frame/Steel/Bolting!We
!ding (Decks)
133554-2020 Partial Pass Paul Burnette
Checklist Item COMMENTS
BLDG-Building Deficiency
07/28/2020 BLDG-31 133993-2020 Partial Pass Paul-Burnette
Underground/Conduit -
Wiring
Checklist Item
BLDG-Building Deficiency
COMMENTS
07/30/2020 BLDG-11 134202-2020 Partial Pass Paul Burnette
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
7/16/20, cancelled per contractor
See plans. Partial pass on foundation walls
7/17/20, GB-3 & spread footings at Line 9
&D.
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wall.
BLDG-31
Underground/Conduit -
Wiring
134281-2020 Partial Pass Paul Burnette
Checklist Item COMMENTS
BLDG-Building Deficiency
08/03/2020 BLDG-11 134515-2020 Partial Pass Paul Burnette
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item
BLDG*Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
7/17/20, GB-3 & spread footings at Line 9
&D.
See plans. Partial pass on foundation walls
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wall.
7/16/20, cancelled per contractor
Reinspection Inspection
Passed
No
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
No
Yes
Yes
Yes
Reinspection Incomplete
Passed
Yes
Relnspectlon Incomplete
Passed
Yes
Yes
Yes
No
Tuesday, October 26, 2021 Page 6 of 36
' ¥" ' ' ' ' fy " \ ;z
· ,., ./.:: .J~E ~ IT INS,ECJ;ION HISJORY for (CBRA2oio-0070)
Permit Type: BLDG-Associated Permit Residenti; Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Cancelled per contractor No
BLDG-Building Deficiency See plans. Partial pass. (4) F4 column Yes
footings.
07/17/2020 07/17/2020 BLDG-11 133151-2020 Partial Pass Michael Collins Re inspection Incomplete
Foundation/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See plans. Partial pass on foundation walls Yes
BLDG-Building Deficiency 7/17/20, GB-3 & spread footings at Line 9 Yes
&D.
BLDG-Building Deficiency 7/16/20, cancelled per contractor No
BLDG-Building Deficiency Underground parking slab on grade at Line Yes
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wa11.
BLDG-12 Steel/Bond 133150-2020 Cancelled Michael Colllns Relnspectlon Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Cancelled per contractor No
BLDG-Building Deficiency See plans. Partial pass. (4) F4 column Yes
footings.
07/20/2020 07/20/2020 BLDG-31 133309-2020 Cancelled Paul Burnette Reinspection Incomplete
Underground/Conduit -
Wiring
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/21/2020 07/21/2020 BLDG-81 Underground 133435-2020 Partial Pass Paul Burnette Reinspection Incomplete
Combo(11, 12,21,31)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-11 F oundatlon-Ftg-Piers No
(Rebar)
BLDG-12 Steel-Bond Beam No
BLDG-21 No
Underground-Underfloor
Plumbing
BLDG-31 No
Underground-Conduit Wiring
07/22/2020 07122/2020 BLDG-12 Steel/Bond 133555-2020 Passed Paul Burnette Complete
Beam
Tuesday, October 26, 2021 Page 5 of 36
Permit Type: BLDG-Associated Permit Residenti: Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021
IVR Number: 24389
Address: 1040 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
Scheduled
Date
06/26/2020
07/01/2020
07/02/2020
07/06/2020
07/16/2020
Actual Inspection Type
Start Date
Inspection No. Inspection
Status
Primary Inspector
06/26/2020 BLDG-21 131193-2020 Partial Pass Chris Renfro
Underground/U nderflo
or Plumbing
Checklist Item
BLDG-Building Deficiency
COMMENTS
Underground waste lines for segment one
to sump pump only. OK to backfill
07/01/2020 BLDG-21 131550-2020 Partial Pass Michael Collins
Underground/Underflo
or Plumbing
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
Underground waste lines for segment one
to sump pump only. OK to backfill
Segment 2 waste to sump pump, Line 9-14
& F.5
07/02/2020 BLDG-11 131780-2020 Partial Pass Michael Collins
Foundation/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wan.
See plans. Partial pass on foundation walls
07/06/2020 BLDG-11 131835-2020 Partial Pass Michael Collins
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item
BLDG-Building Deficiency
COMMENTS
Footing steel for perimeter wall & GB7, Line
A-8 & 11-14.3 only.
07/16/2020 BLDG-11 133018-2020 Cancelled Michael Collins
F OU n datio n/Ftg/Plers
(Rebar)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
COMMENTS
7 /16/20, cancelled per contractor
Underground parking slab on grade at Line
1-8 & A1-A8, need deputy inspector report
for continuous deepened edge steel along
W2wall.
See plans. Partial pass on foundation walls
BLDG-12 Steel/Bond
Beam
133019-2020 Cancelled Michael Collins
Tuesday, October 26, 2021
Reinspection Inspection
Reinspection Incomplete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Yes
Reinspection Incomplete
Passed
Yes
Yes
Reinspectlon Incomplete
Passed
Yes
Reinspection Incomplete
Passed
No
Yes
Yes
Reinspection Incomplete
Page 4 of 36
PERMIT INSPECTION HISTORY for (CBRA2020-0070}
Permit Type: BLDG-Associated Permit Residenti, Application Date: 0112212020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05119/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 1212712021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
06/17/2020 06/17/2020 BLDG-12 Steel/Bond 130321-2020 Partial Pass Paul Burnette Re inspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code Yes
06/19/2020 06/19/2020 BLDG-12 Steel/Bond 130616-2020 Failed Michael Collins Re inspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code Yes
BLDG-Building Deficiency 6/19/20, not ready No
BLDG-21 130617-2020 Partial Pass Michael Collins Relnspection Incomplete
Underground/Under11o
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Building Deficiency 6/09/20, 4" Storm Drain at north end, Line Yes
A1-A8 & AD-AH, stop before interceptor
location.
BLDG-Building Deficiency 6/19/20, 4" & 6" Storm drain, Line 6-10 & D. Yes
06/22/2020 06/22/2020 BLDG-11 130757-2020 Partial Pass Paul Burnette Reinspection Incomplete
F ou ndation/Ftg/P le rs
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial, Line A1 & Aa-AD.5, AA & A1-A6, Yes
A6 & AA-AC, 2.5-6.8 & AC-B.
06124/2020 06/24/2020 BLDG-11 130947-2020 Partial Pass Chris Renfro Reinspection Incomplete
Foundation/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See plans. Partial pass on foundation walls Yes
BLDG-12 Steel/Bond 130948-2020 Partial Pass Chris Renfro Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See plans. Partial pass. (4) F4 column Yes
footings.
06/25/2020 06/25/2020 BLDG-11 131140-2020 Partial Pass Chris Renfro Re inspection Incomplete
FoundatlonfFtgfPiers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency See plans. Partial pass on foundation walls Yes
Tuesday, October 26, 2021 Page 3 of 36
PERMIT INSPECTION HISTORY for (CBRA2020-0070}
Permit Type: BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
BLDG-12 Steel/Bond 128790-2020 Partial Pass Paul Burnette Reinspectlon Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code Yes
06/04/2020 06/04/2020 BLDG-11 129290-2020 Partial Pass Paul Burnette Reinspectlon Incomplete
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial, Line A1 & Aa-AD.5, AA & A1-A6, Yes
A6 & AA-AC, 2.5-6.8 & AC-B.
06/09/2020 06/09/2020 BLDG-21 129636-2020 Partial Pass Michael Collins Reinspectlon Incomplete
Underground/U nderflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 6/09/20, 4" Storm Drain at north end, Line Yes
A1-A8 & AD-AH, stop before interceptor
location.
BLDG-Building Deficiency Yes
06/11/2020 06/11/2020 BLDG-11 129884-2020 Partlal Pass Paul Burnette Reinspectlon Incomplete
F ou n dation/Ftg/P le rs
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial, Line A 1 & Aa-AD.5, AA & A 1-A6, Yes
A6 & AA-AC, 2.5-6.8 & AC-B.
06/12/2020 06/12/2020 BLDG-12 Steel/Bond 130067-2020 Partial Pass Paul Burnette Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code Yes
BLDG-31 130045-2020 Partial Pass Paul Burnette Reinspectlon Incomplete
Underground/Conduit -
Wiring
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/15/2020 06/15/2020 BLDG-21 130179-2020 Partial Pass Paul Burnette Reinspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 6/09/20, 4" Storm Drain at north end, Line Yes
A1-A8 & AD-AH, stop before interceptor
location.
BLDG-Building Deficiency Yes
Tuesday, October 26, 2021 Page 2 of 36
Building Permit Inspection History Finaled
(city of
Carlsbad
P:ERMIT'INSPECTION HISTORY' for (CBRA2020-0070)
Permit Type: BLDG-Associated Permit Residenti, Application Date: 01/22/2020 Owner: CARLSBAD VILLAGE PARTNERS LP
Work Class: Apartments Issue Date: 05/19/2020 Subdivision:
Status: Closed -Finaled Expiration Date: 12/27/2021 Address: 1040 CARLSBAD VILLAGE DR
IVR Number: 24389 CARLSBAD, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
0111512021 BLDG-14 148529-2021 cancelled Tim Kersch Relnspectlon Incomplete
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Yes
BLDG-Final Inspection 153429-2021 Cancelled Tim Kersch Reinspectlon Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLOG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
05/20/2020 05120/2020 BLDG-SW-Pre-Con 128147-2020 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05122/2020 05122/2020 BLDG-11 128292-2020 Partial Pass Michael Collins Relnspectlon Incomplete
Foundatlon/FtgfPlers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial, Line A1 & Aa-AD.5, AA & A1-A6, Yes
A6 & AA-AC, 2.5-6.8 & AC-8.
BLDG-12 Steel/Bond 128293-2020 Cancelled Michael Collins Relnspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code No
05128/2020 05128/2020 BLDG-21 128627-2020 Partial Pass Paul Burnette Relnspection Incomplete
Underground/U nderflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05/2912020 05129/2020 BLDG-11 128789-2020 Partial Pass Paul Burnette Reinspection Incomplete
Fou n datlon/Ftg/P le rs
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial, Line A1 & Aa-AD.5, AA & A1-A6, Yes
A6 & AA-AC, 2.5-6.8 & AC-8.
Tuesday, October 26, 2021 Page 1 of 36
Cl IRIS I IAN WI IEFLER
F N <, I N f-_ I. R INC SEP O 2 2020
I' I 1°: L D R 1°: l'O RT !"I Ill "'Nr.: 01v1s1nl\l
Project Nan1e C:arbbaJ village Lofts CWE# 2200131 Date: 8/31/20 I P.1ge l ofl
Project Address 1 () .. l-{J ( :arh,baJ village !)rice Pcnnit# CllR.\ 20200070 Project Fi1c # Click here to
Contr.1ctor \X'crmcrs Architect ,\()
Subcontractor Thunder Jones , \ W reinforcing Engineer \'C.\
□ lh:inforcnl ( .1mcn:tl' □ 11re-Strcsscd c:(mcrctc □ Reinforced l\lasonry □ I :po"-y .\nrhors □ .Shc>p \Vcl<lmg □ held \Vddmg
□ I Iigh Strrn.i.,>th Hohs □ Nrm-l)csrructiH· ·1·csting □ l\lccharncal ,\nchors □ J<ircpr0<lfing □ Wnod/1\ktal Shear □ \'i/atcrpr<l(Jfing
□ J'ooting ObscffatHm □ .\sphalr Obs/Testing □ Soil ()bs/'!'csting □ Roofing □ HmlJ1ng l·:nn:lnpc 0 Ri:in I( )rcing
Material/Equipment: Reinforcing bar , \ST~l .\ 706 gr 60 .\STM .\615 grade 60
Arrived on site, as requested, to provide the following services:
Special inspection Inspect reinforcing ay level 2 deck North end. Reinforcing sted placement is work in progress.
Inspect reinforcing mat at spread footings, grid 16 at I) and E grid, grid C at 15 and 16 grid. . \nd grid 15 at I) grid.
Reinforcing mat is complete and complies with approved detail.
( ~rade beam 11 at South end of building is work in progress. \X,'ork continues in compliance with approved detail.
4 hrs
NOTED DISCREPANCIES -The items noted bdow were observed to be in non-conformance with the appro\·ed project documents and will rctJuirc
correction or the design engineer's review for approval:
None
NOTICE: UnlL"ss othL"r\\"ISL" stat1..·d, thL" work obsL"rn:J was, to the best of my knowledge, in compliance with the appro\"cJ projL"ct documents. It should bL· noted t
work reported as b1..·ing obsl·rYCd, tested, and opinions c:-;prt'sseJ arc soldy for the benefit of our client and that our prl'sencc and the Sl·ITicL"s prm·iJcJ Jo not rd1cYC tl
contractor from its obli,1.,,ation to med contractual n:uuin·mL·nts.
Rick Riewer SD 237 ICC 1067771 'KJ_~
Inspector/Technician Name Certification# 1nspeclor71 ec1m1c1an s 51gmilure
Initial Distribution: ja viara@wcrmersc( )ITT pa nie s. n )ITT
Reviewer Name Certification# :Renewer!>' 51gnalure
Revit!wed DistnDution:
3980 lfomc ,\venue D San Diego, C,\ 92105 D 619-550-1700 D l'.\X 619-550-1701
I'll'/ I) ltl·l'(lRT
Project Name ( :arbbad vilbgc ] ,(Jfts
!N
CHR I~ l li\N WI l\l II .R
l J\.: C, IN I I RI N (,
CWE# 2200131 D:ae: 8/'.27/20
Project Addrc.~-s ! () .. HJ Carbbad village I )rive Permit# CHR \ 20200070 Project File #
Contractor \\..crmcrs Architect .\0
Subcontractor ·1·hundcrJ(lllC:-i Enginet'r \'C\
[8J Rcinforn·d ( :,>ncrctc □ Pn.:-StrcsscJ ( :oncrctc □ lfrinforccJ /\lasonry □ Epo;;) \nchors □ Shop \X.'clding
□ I ligh StrL'llgth Bolt~ □ Non-Destruct in· T('Slmg □ i\kcharnc:11 .\nchors □ i:ircpnHifing □ \\,.ood/.\ft-1,11 .',hctr
□ h1oting C )h~t·n ,lll<m lJ \sphalt c lbdT(:sting □ Soil Obs/Testing □ goofing □ KrnlJmg J ·:m·d(ipc
Matcrial/Hqu,pmcnt; Reinforcing bar .\ST:-.t . \ 706 gr 60 ,\STi\f .\615 grade 60 ( :oncrctc mix I ksign: 5011504 1: \:= 5000 psi
Arrived on site, as requested, to provide the following services:
Special inspecti(HI h>otings dug at south eJgc, Reinforcing mat fabricated for spread footings.
I Page 1 of 1
Click here to
□ hclJ \X.\.:lding
□ \X.'atcrpnJ<1fing
□ lkinf1ircmg
supplied by I Janson
Tendon anchors at level 2 deck installed, North edge. Dcliwries of reinforcing bar. Inspect reinforcing bar ar column drop heads, rcinforcing bar complies
with specificarion, is work in progress.
Reinforced concrete placement at level 1 columns at grid locations: (;_3 and 11 grid at 10 grid. C.3 grid and 1:_3 gm\ at 12 grid, Crid l-'.3-13.
Total 5 column !orations were placed. Total of 6 cubic yards wcrt· placed by bucket. Strength test specimens were made. J!idd testing was performed.
\X'ork and materials were in compliance.
9.5 hrs.
8 hrs
NOTED DISCREPANCIES The items notnl bdow were observed to be in non-conformann· with the approved project documents and will rct1uin:
correction or the design en_l..,'1m-cr's review for approval
None
NUTICE, Unkss othL"nnse stated, thL· work obsLT\TJ \\ ,1s, to the bi:st of my krn)wk-Jgi:, in compliance with the appro\·l"d projl'Ct d()Cuml'nts. It should bt· noted that thl·
work reported as bi:ing obscrYcd, tcstcJ, and opinion~ c'-pn-~~cd ,uc solely for thl' benefit of our client and tlut our prcscncc and till' Scf\'iccs pro\"1ded do not rdicn· the
,·m1tractor from its obligation to nll'ct contractual rniuircmcnts
Rick Riewcr SD 237 ICC 1067771 '}<.2~
ln.<tpector/Technician Name Certification# 1n.~pedor? 1 cc1imc1an s "S1gna1lln:
Initial Distribution: javiarail)wcrmersnlmpanics.cr>m
Reviewer Name Certification# ~cv,cwers -S1g11alun:
Reviewed Distn'bution:
3 9 8 0 11 om c .\ v c nu c D San I) i cg n, C .\ rJ 2 t O 5 D 6 t 9 -5 5 0-170 0 D I;.\ X 6 1 9 -5 5 0-170 1
w
Cl IRISI IAN WI ll+LFR
l 'l (; 1 1\ I I R I~(,
l'll:J D RFPORT
Project Name Carlslud Village Lofts CWE# 2200131 Date: 8/24/20 / Page 1 of 1
Project Address I 040 Carlsbad \'illagc Dr, Carlsbad Ca Pennie# c :P.R 10200070 Project File#
Co11tr.1ctor \X'crmcrs Companies Architec:t ;\()
Subco11tr-.lctor ·1·hundt:r Jones, ,\ \'(' Rcinfnrcmg Engi11ccr \'C. \
□ l\Cmforccd { :oncrt:!c □ l'rc-Stn;ss,:;d C:oncrctc □ lkinfr,rccd ;-..Jas(1nry □ 1 •:poxy .\m,;hors □ :-ihop \X't:!Jing □ hdJ Welding
□ I f1gh Strrngth Holts □ Non-f)cstruct1n: "J'cstmg □ l\kchanical .\nchors □ Fm.:rnmfing □ \'\-'ood/\kul Shcar □ \"'\,'atcrpnH1fing
□ l'(Hllmg ()hscr,ati(m □ ,\sphalt ( )bs(l'cstmg □ Soil Obs/Testing □ H,,c,fing :J Building Fnn:lopc 181 Rcb:1r
1'/atenill/Equipment: .\706, 615 (;raJc 60 Rebar
Arrived on site, as requested, to provide the following services:
Special lnspt·ct10n of the reinforcing steel bars for the Level 1 shear walls, Along (;ri<llinc I '., ( ;ml.line 10 and (indline B. Non contact lap splices
throughout.for shotcrcre. \Xiork done in gcn('ral confonnancc with the pbns. 4 hours bhor.
NOTED DISCREPANCIES -'llu: items noted below were obser,;e<l to be 111 non confonnancc with the approved project documents and will rctiuire
correction or the design engmeer's review for approval:
'...:,Jnc
NOTICE: Unless othern·1se stated, the work obscIYc<l was, to the best of my knowledge, in eompl1.tnee with the approYcJ prorect documencs. It should lie nored that thl'
work reported as heing obscned, tested, and opmions t·xpn:ssl"d are soldy for the hendit of our cl1L·nt and that our presence and the sernccs proYided do not relicYc the
contractor from ,cs obligation to meet comractual reqmrements.
~ N, t1_. John Shirley San Diego 107 4
l Tcch~;ician .. ~~ S'nature lm,pector/Technidan Name Certification #
Initial Distribution: javiera@~cnncrscompanics.com, ryanw(i{:wcnncrscompanics.c(lffi, jessiacg0}wcnncrspropcrttcs.com,
. , ·.· . '. , ,,
Reviewer Name Certification# Reviewer'i; Si"gnaturt:
Reviewed Distribution:
3980 llomc ,\vn1uc D San Diego, C,\ 92105 0 619-550-1700 D 11,\X 619-550-1701
! ?miect Nome {7 ~J 6 c_ c/4 o0
' ,", -.,j.-,;L; ;...;:;dres;,
d-lRJS !L>,N \Vl-i!:'ELEI/,
f~r;i~FFRl:,,r(;
1 f->errnit # Plan file t1-
i Ccntcct".V r ,;e M CE s : Acchitect,A--{.) 1s-~~~k---z ~--------_------------~i_E_,._:._,c_c_,V __ C_~ ___________________ ___,
II O Reinforced Concre:-~~-'---~e--Stressed Concrete O Reinforced Mmonry O Epo:-1..;"ncho'}'
. D Shop Welding □ Field Weldins;i n Fireproofing .P:::---Ka~4.L'6,--
"j,1-,_;t;;i;:;1/Eq'~"ipmenh
Weather,
r
I ·r
---------------------------------,
Un.less noted olherwise, t~ work obserYed is, lo tit& best of my knowledge, in co plionce with the opproved plans and spedticotions.
''"""''a!.!;2~,11!1 --,-6:Z-,~if:J ;L:__S_,;5:=,:-c__;":-,,,-,J,-,,,-.,-Sic-."-"'-""-_ ----------o-c,-c --
l~•ec~:(:,q,{,~1,µ~/{_ J;X i
-~92l P.fercury Street+ Sr?.~ Di.ego, C:\ 92111 -+-858-496-9760 + FAX 858-496-9758
!N
Cl IRIS I IA;\/ WI IFFLI R
l '\ <, I ' I I R I 1'. (,
1:r1:1 D RJ,'P<>HT
Pro/1._•ct Name Carlsball Village Lnfrs CWE# 2200131 Date: 8/1.)/20 I P.,gc 1 of1
Project Address 1040 Carbb:1d \'dbgl.: Dr. c .. uhlnJCi. Pcnnit# CRR 20200070 Project File #
C011tractor \'{'cnni.:rs (:ornpa1i1cs Architer·t ,\()
Subcontr.1ctor 'l'hunJi.:r J1>11cs, .\ \\ Rctn{(1rn11g Engineer \'C I
□ Rc1nforccd { :(J!lCKtl' □ l'rc-Scrcs-:cd ( :oncrLtc □ lk1nforccd \hsonry □ Fpo-:y \m:hors □ Slmp \\\:!ding □ Field \'i/clJmg
□ Il1gh :-itrmgth H(,lts □ '\.:on-I kstruct,n: "J',·s1111g □ J\kcha,m:al .\nchors □ l;1n;proofing □ \\'ooJ/\kul She.tr □ \Va1crpn1,1f,ng
□ Footing ()hscn"al1on □ \sphalt ( lbs/Tc:;1111g □ S,)11 ( lbs/Tcstmg □ \{(Hofing □ Bu,ldmg FmTl,Jpc 0 lkb.1r
AIJ.tcn"al/Equipmcnt: ,\615.706 c;nidc (JO Rebar
Arrived on site, as requested, to provide the following services:
Speci:1\ Inspection nf the reinfr,rcing steel hars .1t the basement slab on grade ramp area, ( ;ndhne 11 to 14 and c;1, H to 1: #·~ b.trs insralkd ({1)16" F\X-'.
This ar('a is ready for concrete. Rebar msr:1llation done in general conformance with the plans. 4 hours labor.
NOTED DISCREPANCIES 'll1e Items noted below were observed to be 111 non-conformance with the approved pro1ect documents an<l will re4uire
corn:ct1rn1 or rhe des1gn en1-,rineer's rev1ew for approval:
NOTICE: Tr should be noted that thL· Unless uthl'rn·i~l' sL\tl'J, d1l' \\·ork obsl'n-ed w;is, Co the lx:st of my knowledge, m compliance \\'lth the apprm·ed project documents.
work reported :is hl'ing obsenTd, tested, :ind opirnons cxprl·sscJ arc solely for the bcndit or our cliL·nt :mJ th:11 our presence am.I 1he sen·inis prnYidcd do not n:lic,-c the
cnntr;u:tor from 1ts oblig;uion to meet contr:u:tual re'-lu,rcments.
~ M. IL • .John Shirley San Diego 107 4
I Technician' . ., s/nafllrt: Inspector/Technician Name Certification#
lnilli1/ Distribution: javil'ra({t1.wenncrscompanit:s.c(Jm, r;anw@wcrmcr~n1mpanit:~.crim,Jl'~sicag(ii;\vcrml'rspropl'ftie~.com,
' ·'· , _, ' ' . . . , .
Reviewer Na111e Certification # Revien:er',<, Sig11aflln:
Reviewed Distribution:
3980 fJome ,\ycnue O San Di(·go, (:.\ 92105 0 61')-550-1700 □ 1.-.\X 619-550-1701
~N
U IRl~TIAN WI 1111.lR
I '\, (, ! ]\ r r R I l\ (,
C(l,\[l'ltl•:SSIYI•: STitU,(;111 ·n:sT RI Sl'LTS
Job Name: Carlsbad \'ilbgc Lofo CWE# 2200131 Client:
Job Address: 1040 Carlsbad \'i!lagc Drive, Carlsbad Permit#: <:Blt\ 2020 0070 Plan File#:
Contractor: Architect: .\rchircct ( >range
Subcontractor: Thunder Jones Engineer: \ r:.1
Test Location: Hasrn1ent Ramp (d: (;nJlmc 12C Supplier I lan:-on
Req. Strength: 2500 psi Mix#: 25.DSOO
Date Sampled: 08-1--1--20 Admixture(s):
Date Received: 08-1-::;-20 Truck#: S98 Ticket#: 88,803
Sampled by: JS Mix Temp: 78° Air Temp: 7:;o
Tested by: T\:-i Slump: 5" %Air
Sample Type: Concn·!l' ( \lindcr --1-" x 8" Min in Mixer: .lS Wet Unit Wt:
Notes:
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
8815 08-21 20 ~ 4.00 12.566 27,490 2,190 \
8816 09-11 20 28 4 00 12.566 .1-l-,S-1-0 2,750 3
8817 09-11 20 28 4.00 12.566 36.110 2,890 2
8818 09-1 I 20 28 4 ()() 12.566 .%,920 2,940 4
The sampling, handling, curing and compressive strength testing were pertormed by Christian \1\/heeler Engmeenng 1n accordance with the applicable ASTM standards. No
other warranties, express or implied
Distribution:
ryanw(<..!_;wcrmcr:-.c(ltnpanics.u )lll
j a vie ra (<?we rm lTSn ll n panics. c< ltn
jessicag(ti;w(·rmcrso nnpanic:-.uim
City of Carlsbad
Supplier
i
!
~~-]
' ' i 1-,i
Reviewed by
a
Charlie G. Carter Jr, RCE #61968
3980 !Jome .\\'l'tlUC ♦ San Diego, C.\ 92105 ♦ 619-550 1700 ♦ 1-'.\X 619 SS0-1"701
w
Cl IRIS 111\" WI lfTLrn.
f-'\<.I'\ f-f-RI'-"<,
C:(l,IPRl·/SSJ\'J,: S'J'RIN(;TJJ '11,ST RFSJ'LTS
Job Name: ( :arl:,;bad \'illagc I ,oft:--
Job Address: 1040 Carlsbad \'illagc Dnvl', Carlsbad
Contractor:
Subcontractor: 'J'humkr J()n,·:,;
Test Location: Ba:,;cmrnt ( :olumn@ ( ;ridlinc 1.V:
Req. Strength: 5000 psi
Date Sampled. 08-11-20
CWE#:
Permit#:
Architect·
Engineer:
Supplier:
Mix#:
Admixture(s):
2200131 Client:
{ :BR.\ 2020 0070 Plan File#:
. \rchitLTt ( )range
I Janson
5011504
Date Received: 08 14-20 Truck#: S99 Ticket#: 883980
Sampled by: JS Mix Temp: 78° Air Temp 6S0
Tested by l'\S Slump: 5" %Air:
Sample Type: c:()!lCrctc c:ylmdcr 4" x 8" Min in Mixer: 35 Wet Unit Wt:
Notes:
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
8696 08-18-20 7 4.00 12.566 61,320 4,880 6
8697 09-08-20 28 +oo 12.566 8+,640 6,740 '
8698 09-08 20 28 400 12.:166 84,820 6,750 6
8699 09-08-20 28 -UlO 12.566 85,190 6,780 i
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering in accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution·
rya 11 '-N(i i; WlTll l l'f~C( 11n pa 11 ic S. Cl ltn
j a\' i cra(//wc rmc rsn 1mpa n ic ~. n im
{ :ity of ( :arlsliaJ
Supplil•f
I_ I
t:·'t\,:_;e,,.,,
"""''''
[ ·--
r-
' _J
T,,H"I 1,1-~:
Reviewed by:
a •
Charlie G. Carter Jr, RCE #61968
3980 llomc .\venue ♦ San Diego, C:.\ ()210'1 ♦ 619 SS0-1700 ♦ 1:_\X 619-SS0-1701
C
w
Cl 11,ISIIA'\ WHITI.IR
! '-.;Lll\;ffRINr,
C () ,! P R ES S I V E ST RE 1' GT fl TFS T R ES L: I.TS
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
( :arlsbad Vitlagc Lofts
1040 Carlsbad Village DriYc, Carlsbad
\\'nmcrs Cumpanic~
Thunder .Jones
LeYel 2 Hascmcnr Parking@ Gridline 9F
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
2200131 Client:
CHRA 202(1 0070 Plan File#:
,\rchiti.:ct Ornngi:
\'CA
Hanson
253351)()
Date Received:
2511() psi
(l7-31-20
08-ll.1-2() Truck#: 5()9 Ticket#: 881S98
Sampled by:
Tested by:
Sample Type:
Notes:
Sample#
8434
8435
8436
8437
JS
NS
Concrete Cylinckr 4" x 8"
Date Age
Tested/Issued (days)
08-07-20 "
08-28-20 28
-
()8-28-20 28
!l8-28-2() 28
Dimensions/
Avg. Dia. (in.)
4.00
4.(HI
4.00
4.00
Mix Temp: 78° Air Temp: 720
Slump: 6" ¾Air:
Min in Mixer: .15 Wet Unit Wt:
Area Maximum Load Comp. Strength
(sq. in.) (lbs.) (psi) Fracture Type
12.566 26,07() 2,070 s
12.566 42,750 3,400 1
12.56() 41,880 3,330 4
12.566 42,93() 3,420 4
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering m accordance with the applicable ASTM standards. No
other warranties, express or implied.
Distribution:
ryan\\·(d;wcrmcrscompanies.com
janera@wermersc(Jmpan1es.c()!11
City of Carlsbad
Supplier
i , I I
I
'
1.1,'
,,~' ,.,, •. ,.,,,,,,c-,i,,:,
'"""~' .. a,, ,,,,.,, ,,,.,. ,,,,,.,
Reviewed by:
Charlie G. Carter Jr., RCE #61968
.1 9 8 ll Home Avenue ♦ San D 1 c µ; n, C . .\ 9 2 I ll 5 ♦ (1 1 9 '.) S (I I ~ ll () ♦ FAX Ci 1 lJ -5 5 () -I 7 () !
D
~· CHRbllAN Wll[[L[R
I '\J (, I ;,...; I I 1-Z I '\J ( ,
C <l ,I P R F. S S I VE ST R EI\ GT II T EST RES l' LT S
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Date Received:
Sampled by:
Tested by:
Sample Type:
Notes:
Sample#
8430
8431
~-
8432
8433
Carlsb,1d Village Loft~
l 04lJ Carlsbad Village DriYe, Carlsbad
\\'t.:rmcrs Companies
Thunder Jones
Le\'d 2 SOG (ft'; Gnd!ine 1.W
2500 psi
lP-31-2()
08-(l1-20
JS
NS
Concrete Cylinder 4" x H"
Date
Tested/Issued
08-07-21)
()8.28·20
il8 28-20
08 28-20
Age
(days)
-
28
28
28
CWE#
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump:
Min in Mixer:
Dimensions/ Area
Avg. Dia. (in.) (sq. in.)
4.00 12.566
4.011 12.SM
4.()() 12.5(><1
4.00 12.56(1
220013 I Client:
CBRA 2()20 (Hl70 Plan File#:
Architn:t Ornnge
\'L\
f lanson
2533500
6.)} Ticket#: 881570
78° Air Temp: 72°
6" %Air:
}5 Wet Unit Wt:
Maximum Load Comp. Strength
(lbs.) (psi) Fracture Type
14,590 2,750 6
48,710 3,880 1
50,42() 4,010 I,
49,350 3,930 6
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engmeenng m accordance with the applicable ASTM standards No
other warranties, express or implied
Distribution:
ry,mw(tijwermerscnmp,1nies.cnm
j a Yi ern(4!werm ersn m1 pan ies .com
City of Carlsbad
Supplier
k.
' I ' ' L~
,.,,
'"1-f,'"•"''"·'
Reviewed by:
LJ
1,,.,,
~","'"'';,.t.,, •'"""'
Charlie G. Carter Jr .. RCE #61968
l 9 8 (I Home r\ venue ♦ San Die i!: o, C ,\ 9 2 I O 5 t Ci I 9 -:i 5 () -I : ll ll ♦ FAX C1 I 9 -5 5 11 -I 7 O 1
!N
CIIRISTIAN WIIITI.IR
I '.J (, I J\.' I I RI N r,
CO;'-.fPRESSIVE STRENG"rH TEST RESl1 LTS
Job Name:
Job Address·
Contractor:
Subcontractor:
Test Location·
Req. Strength:
Date Sampled:
Carlsbad Villa!,';c I ,ofts
I 04() Carlsbad \'illagc Driyc, Carlsbad
\\'nmers Companie~
Thunder Jones
I .cYel I Column @ Grid line Al I & t\4
5000 psi
l17-Jl-2U
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
2200131 Client:
CBRA 2020 0070 Plan File#:
r\rchitcct ( )range
\'C.\
I lan'>on
5011504
Date Received: (}8-(l.1-20 Truck#: .181 Ticket#: 881779
Sampled by:
Tested by:
Sample Type:
Notes:
Sample#
8426
8427
8428
8429
JS
NS
Crincn::rc (\lirnkr 4" x 8"
Date Age
Tested/Issued (days)
08-07 .20 7
08-28-21) 28
ll8-28-20 28
08-28-2() 28
Dimensions/
Avg. Dia. (in.)
4.00
4.UO
4.00
4.00
Mix Temp: 78° Air Temp: 720
Slump: ' %Air:
Min in Mixer: .15 Wet Unit Wt:
Area Maximum Load Comp. Strength
(sq. in.) (lbs,) (psi) Fracture Type
12.SMl .i8,240 4,630 (,
12.566 73,.\'i() 5,840 4
125(i() 71,S(iO 5,690 ]
12.566 74,.i71l 5,930 2
The sampling, handling, curing and compressive strength testing were performed by Chnst1an Wheeler Engmeenng m accordance with the applicable ASTM standards. No
other warranties, express or implied.
Distribution:
ryanw(Cl!wermerscom pa ni es. cc Jm
i a viern@we rmerscornpanie s .e< lffi
(:ity of ( :arlsbad
Supplier
i
I
! ' j
,,,..,, ,,,,,.,.,,,,,,._.,.,,c1,,\,
~'-"~' ,ai; C ;~~• ,._,, ,.,, ,.,. ~ ,-, ,-,1
Reviewed by:
C
Charlie G. Carter Jr., RCE #61968
] J
:,,r,·'
""''
1 9 8 0 Ho m c A\' en u c ♦ S :1 n D i ego, C A 9 2 I () .S ♦ 6 1 9 -S 5 0 I 7 lJ IJ ♦ FA X 6 1 9 -'i 5 () -I 7 0 1
r l~J
w
U IIUSTIAN WI IFH.ER
I:-...; t, ! I\\-1-R Ir'...(,
C () :---t PRE-"' SI\' E ST l{ EI\ CT II TEST RES l I LT S
Job Name·
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength·
Date Sampled:
c:arlsbaJ \'i\bgc l.ofo
I 040 ( :arlsbad Village l)rivc, ( :arlsbaJ
\X'crmcrs Companies
Thunder Jones
Level 2 Column «f; ( ;nJlinc 6H
5000 psi
07-30-20
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
2200131 Client:
u--m.\ 2020 0070 Plan File#:
.\rchitcn ( )rangL:
I Janson
5011504
Date Received: 07-31 20 Truck#: 636 Ticket#: 881432
Sampled by: JS Mix Temp· 78° Air Temp: 72°
Tested by: ~s Slump: 5" %Air
Sample Type: ( :oncrctt· Cylinder 4" x 8" Min in Mixer: 35 Wet Unit wt:
Notes:
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
8410 08-06-20 7 4.00 12.566 63,920 5,090 6
8411 08-27-20 28 4.00 12.566 80,820 6,430 4
8412 08-27-20 28 400 12.566 78,560 6,250 3
8413 08-27-20 28 4.00 12.566 77,910 6,200 3
The samplmg. handlmg, curing and compressive strength testing were performed by Christian V\lheeler Engmeermg m accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
rya n w (t/_;wnmcrscc )tnpa n ic s. cc )tn
i :l vi, ·r:1(ii}wcrmc r~ n imp;1 nil'~. C( ) m
City of Carbhad
Supplier
i . L __ I
' ' ' i Ii
1,
,,,,,,,1 .... , .. ,.,.c,,, .,,,,,,1,•·~·" ,. " ..... ,,,,,,,,~·-.,,
Reviewed by:
Michael B. Wheeler, RCE #45358
3980 llon1e .\venue ♦ San D1qi;o, C:.\ 92105 ♦ 6JCJ-.1S0-1700 ♦ 1-'.\X 619-550-1701
[
"'"'""'" ,,re,,,,.
~N
CHR\o IIA'-1 WI \LLLIR
I '-.; r, IN I ! 1-t IN c,
CC)i\lPRESSIVE STRENGTH TEST RESl'LTS
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Date Received:
Sampled by:
Tested by:
Sample Type:
Notes:
Sample#
8351
8352
8353
8354
( :arlsh,HI Village Lofts
1040 Carlsbad \'i!lage Dri\'c, Carlsbad
\\'crmers Companies
·1·hundcr Jones
I .eve! 2 Column (d; GriJ\ine 7F
5000 psi
07-10-20
JS
NS
Concrete Cylinckr 4";,.; 8"
Date
Tested/Issued
08-05-20
08-26.:?:o
()8-2(,-20
118-26•20
Age
(days)
-
28
28
28
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump:
Min in Mixer:
Dimensions/ Area
Avg. Dia. (in.) (sq. in.)
.. J..l)() 12.566
4.UO 12.566
4.00 12566
4.00 [2.566
220on1 Client
CBRA 2020 0070 Plan File#:
r\rch1tL:CI Orangl'
\'Cl
I lansnn
5011504
579 Ticket#: 88107.1
78° Air Temp: 72°
5" %Air:
.1.'i Wet Unit Wt:
Maximum Load Comp. Strength
(lbs.) (psi) Fracture Type
61,84() 4,920 5
82,!90 6,540 4
8\6(i0 6,660 2
81,450 6,480 3
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering in accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
ry ,rnw(!:L': we rm crscc >m p;mics. C( JIU
j,1vicrn@wcrmcrsetJmpanics.com
Cit,· of Carlsbad
Supplier
I~ I
I' •, ,I L _ _j LJ ' '
' C u
Reviewed by:
Michael 8. Wheeler, RCE #45358
.198(1 llome Avenue ♦ San Diego, C,\ 921()5 ♦ 619 550-1700 ♦ F,\X 619-5511-\701
D ·~ .,,
w
U IRJS 11!\N WI I\ !UR r ~<,Ir-._ f-I RI-...,(,
Job Name: < :arh,bad \'ilbgc I ,ofts CWE# 2200131 Client:
Job Address: 1040 C::1rlsbaJ \'illagc DrivL·, Carl:-;\,aJ Permit#: ( J-Hl.\ 2020 0070 Plan File #:
Contractor: \\'cnncr:-. ( :ompanil'~ Architect: . \rchitcn ( )range
Subcontractor: Engineer:
Test Location: Lcn-1 I Column, ( ;ridlmc 91) Supplier· l lan:-on
Req. Strength: sooo r~i Mix#: :i01:i04
Date Sampled· 07-27-20 Admixture(s)·
Date Received: 07-28-20 Truck#: 650 Ticket# 880-1-7:i
Sampled by: IS Mix Temp: 78° Air Temp· 75°
Tested by· ~s Slump: :i" %Air:
Sample Type: Concrete Cylinder 4" x 8" Min in Mixer: 3:i Wet Unit Wt
Notes:
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in I (lbs.) (psi) Fracture Type
8225 08-03-20 C mo 12.566 61,(110 4,860 6
8226 08 24-20 28 -l.00 12.:166 9-l,6\ll 7,530 -l
8227 08-2-i-20 28 4.00 12.566 94,230 7,500 l
8228 08-2-1--20 28 -l.00 12.S66 9_\070 7,570 3
The sampling, handling, cunng and compressive strength testing were pertormed by Christian Wheeler Engineering in accordance with the applicable ASTM standards No
other warranties, express or implied
Distribution:
ry ctn w(i I; wL·rm L·rsn nnpa n ics. c< nn
ja vie ra (i_"i;wc rn1LTSC< Hnp an ic~· .n i1n
Cny of Ca,-\sh.1J
Supplier
L_ ___ )
r,./ .,_..,,,,,,_. on-,,..,.-.. ,.,_,,,,,.c,'J
'rou;o,~.; '''·"' Ci,1'~•; 0,, .. -,•,,<.-l"I
Reviewed by:
Michael B. Wheeler, RCE #45358
r,, .. , ,,o'al,,,,.,
tl<l(t,o,("·'' ,,,,1
3980 lloml' \vl·nuc ♦ San Dit·go, (:.\ 92105 ♦ 619-550-1700 ♦ 1:_\::\ 619 550-1701
~N
l 'I IK ISi 11\N WI l[[l[K
I '\J (' I "-.J r r I{ I '\J ('
COMPRESSIVE STRFNGTH TEST RESL'LTS
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location·
Req. Strength:
Date Sampled:
Date Received:
Sampled by:
Tested by:
Sample Type:
Notes:
Culsbad Vtl\agc Lofts
1040 Carlsbad \'1\lage DriYe, Carlsbad
\\'crmcrs C(Jmparn<.:~
Thunder Jones
Podium Deck # 1 -Gridlinc 4 -r
SIHHI psi
(l7-2-1-2ll
07-24-20
Sac
NS
Ccmcn:tc Cylinder 4" x 8"
CWE#
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump·
Min in Mixer:
Dimensions/
2200131 Ghent:
CHRA 2020 0070 Plan File#:
Architect Orange
\'CA
Hanson
5033.1444
594 Ticket#: 8797(i0
86° Air Temp: 7c;o
_"i" ¾Air:
3() Wet Unit Wt:
Maximum Load Comp. Strength Date Age Area
Sample# Avg. Dia. (in,) (sq. in.) (lbs.) (psi) Fracture Type
Tested/Issued (days)
~
8098 07-27 20 4f<C: 4.00 12.566 55,321) 4,400 6
8099 07-?i!l-20 " 4.00 12.566 6(1,310 5,280 4
8100 08-20-21) 28 4.0(1 12.S(i<i 79/iW 6,340 '
8101 08-2fl-20 28 4.00 [2.56(1 77,590 6,170 6
8102 08-2(1-20 28 4.0ll 12.566 7CJ,l20 6,300 3
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engmeenng m accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
ryanw(Cl[wcnncr~nnnpamc:;~.com
j a, ·Kr,1 (lVw(-rJnl·rsn 1111 panics _C( m1
City of C1.rhbad
Supplier
i
I!·
i
i LJ J ~
!' l J i
I ' ~-
fi,J , .•• e•L,A .,_,,,
Reviewed by·
Michael B. Wheeler, RCE #45358
J 9 8 () H nm c ;\venue ♦ San DI cg o, Cr\ 9 2 l () 5 ♦ 6 I 9 -S SO -l 7 () () ♦ FAX 6 1 9 5 5 0 -I 7 () 1
~I :· 1
I I Li
-
w
l] IRblli\N WI IUl.1 R
I '\J <, I t..; I I I\ I N (,
C O ,\I P R ES S I V E ST R EI\: GT H T EST R ES l' I.TS
Job Name:
Job Address·
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled
Date Received:
Sampled by:
Tested by:
Sample Type:
Notes:
~·
Carlsb,ul Vil!agc J,ofts
104() Carl~had Village Drive, Car\~bad
\\'<.:rmcrs Comparnc~
Thunder Jone~
Podium Deck# 1 -Gridlinc 1 -C:
5(1(l(J psi
(J?-23-2()
07-24-2(1
SaC
NS
Concn:rt: Cylinder 4" x 8"
Date Age
CWE#
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump:
Min in Mixer:
~----
Dimensions/ Area
220013[ Client:
CHRi\ 2ll20 ()()70 Plan File#:
r\rchitl"ct ( hangr:
\'CA
Hanson
S033:5444
().12 Ticket#: 8-:'%94
86° Air Temp: 68°
S" %Air:
2() Wet Unit Wt:
Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
---
8103 07-27-20 4FC 4.U0 12.566 55,77() 4,440 "
8104 ()7-)0-20 -4.{HI 12.566 65,260 5,190 4
~----·
8105 08 20-20 28 4.00 12.5Ml 8(1,470 6,880 '
8106 (18.2()-21} 28 4.00 12.566 84,160 6,700 1
8107 ()8-2[1-21) 28 4.()() [2.56() 83,240 6,620 4
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engmeermg 1n accordance with the applicable ASTM standards. No
other warranties, express or implied.
Distribution:
rya n ,,_,,_-(a;wcnnt' r~u 1n1 pan ie s .com
j ;1 ncrn(tl!wcnnersn 1 m pan it.: s. u nn
Cit\· of Carl~bad
Supplier
I
I.
I C .
Reviewed by:
Michael B. Wheeler, RCE #45358
r ·-
I
L__. __
1·, ••. , '.,~, . . ,, ,,.,,,
19 8 () Hom c Av c nu e ♦ San D leg 11, CA 9 2 l 115 ♦ 6 I 9 -5 5 0 -I 7 () U ♦ l; AX 6 I 9 -S .S (I -l 7 ll I
r~
:' 1
LJ
'w• ., .
~
-~
!N
Cl IRISTIAN WI ILLLLR
I ' <, IN I I ll I 'J <,
C: O ;\f PRESS IVE ST RI·'. I\' c; TH TEST RES l' I.TS
Job Name:
Job Address:
Contractor:
Subcontractor
Test Location:
Req. Strength:
Date Sampled:
Date Received:
Sampled by:
Tested by:
Sample Type:
Notes:
C:arlsb,1d Village Lofts
1040 Carlsbad \'illagc Dri\'l:, Carbbad
\\'o::rmers Companies
Thunder Jones
Podium Deck # I -Gri<l!ine 2 -F
5000 psi
07-23-20
()7-24-20
SaC
C(lncrdc Cylinck:r 4" x 8"
Date Age
CWE#,
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump:
Min in Mixer:
Dimensions/ Area
22U0131 Client:
CBRA 2020 0070 Plan File#:
Architect ( )range
\'CA
Hanson
.'iOJ15444
587 Ticket#: 87%.1.1
8(1° Air Temp: 66°
' %Air:
.1/J Wet Unit Wt:
Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
8108 07 .27 -21l 4H: 4.00 12.566 _::;2,19U 4,150 (,
8109 07-_1U-20 0 4.UO 12.566 59,840 4,760 4
8110 08-2(1-20 28 4.00 12.SMi 81),(19() 6,370 1
8111 08-211-2() 28 4.011 12..566 n,320 6,310 2
8112 08-20-20 28 4./lll 12.5(iC1 77,550 6,170 4
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Eng1neenng in accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
ry anw(Uiwermer~i.: 1 >m pan i <.: ~ .u, m
j a Yina(liiwc rmc r SC( >m p.1nics .com
City ofC:i.rlshad
Supplier
I ' I.
LJ
I!•
l~ 1:J r, D r· i· -.: ['· I ~ ' . I
1ftT,5
'"""''·'>'-''"~' '""'"'"" ,,,•,<;'(··,,J
Reviewed by:
Michael 8. Wheeler, RCE #45358
_'l, 9 8 ll Home Ave nu c ♦ San Die g n, CA 9 2 I ll 5 ♦ 6 l 9 -5 5 (l -I 7 () I) ♦ FAX 6 I 9 -5 5 (I -1 7 () 1
--
!N
CHRISll:\:\I WHITUR
r '\J <, 1 ~-r r R I J\.' <,
C <l ~I I' RESS I V E ST REN GT II TEST RES L' LT S
Job Name:
Job Address:
Contractor:
Subcontractor
Test Location:
Req. Strength:
Date Sampled:
Date Received:
Sampled by:
Tested by:
Sample Type:
Notes:
Carlsbad Villaµ;c L()fo
104() C:arlsbad Village DriYc, C:arlsLad
\X'crmers Cumpa1m:s
Thunder Jones
Podium Deck # 1 -Gridlme l -D
SOOIJ psi
07-23-2(}
SaC
NS
C 1ncn.:rc Cvlindcr 4" x 8"
Date Age
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump·
Min in Mixer:
Dimensions/ Area
2200131 Client:
CBRA 2020 0070 Plan File#:
Architl·ct ( )rnnµ;t:
\'C\
f lanson
50335444
(1.10 Ticket#: 879(133
78° Air Temp: (Ao
4-3/4" %Air:
4IJ Wet Unit Wt:
Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
-
8113 07-27-20 4FC 4.UO 12.566 60,6\() 4,820 4
8114 07-10-211 -4.0U 12.56(1 67,(110 5,380 1
---. ------f----------------
8115 08-211-20 28 4.(HI 12.SMi 79,400 6,320 2
8116 08-20-20 28 4.nn l2.."iM> 77,280 6,150 3
8117 08-2ll-20 28 4.0() 12.566 79,810 6,350 !,
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engmeenng m accordance with the applicable ASTM standards. No
other warranties, express or implied.
Distribution:
ryan,.,. -(i?1 we rmcrs comp anic s. cun1
j a \·icra(diwcrmr.:rso 1 rn p,1 n i cs. Cl )m
City of Carlsbad
Supplier 1,,.~-.•·,,, ,-·•~< ,,, .• , I
Reviewed by:
Michael B. Wheeler, RCE #45358
oe·~•' o "-'' , . . ,, ,_,,,
_19811 Home r\ venue ♦ San Di cg n, Ci\ 9 2 I ll 5 ♦ h I 9 .i .i (I -I 7 () 0 ♦ FAX 6 I 9 -S 5 O -I 7 0 1
1
71
-J
!N
Cl IRISTIAN W\HlLIR r '..: t, I :--JI I R. IN r,
C O :,.,1 P R ES S l V E ST RF 1': GT H T I·'. ST R ES L' LT S
Job Name:
Job Address·
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Date Received:
Sampled by:
Tested by:
Sample Type:
Notes:
-----
Carlsbad Village Lofts
!040 C:arlsbad \'1l!agc Drin:, Carlsbad
\\\:rmcr~ CompanH:~
Thunder Jones
30()() psi
IF-22-2(1
07-23-2(1
JS
Concretl'. C)lindcr 4" x 8"
Date
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump:
Min in Mixer:
Dimensions/
22(1()1:,] Client
CHRA 2ll20 iHl70 Plan File#:
1\rchitl'.ct Orangt:
\'C\
I famon
.'>033.ST'l
589 Ticket#: 879S09
78° Air Temp: 750
5'' %Air:
35 Wet Unit Wt:
-
Maximum Load Comp. Strength Age Area
Sample# (days) Avg. Dia. (in.) (sq, in.) (lbs.) (psi) Fracture Type
Tested/Issued
--·
8001 07-29-21) --1-.00 12.566 ."il,.)lJO 4,090 4
8002 118 19-20 -4.00 12.566 58,090 4,620 '
8003 118 19-20 28 4_{)() 12.5Mi 6!1,440 4,810 4
8004 08-19-20 28 4.nn 12.."iM 61,570 4,900 G
The sampling, handling, curing and compressive strength testing were performed by Chnst,an Wheeler Engmeenng in accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution·
ry-,1 n w(d,v.,erme rscom panics.com
j a \·iera@wcrm erscnm panics. C< Jl11
City of Carlsbad
Supplier
I<
I.
'-
~ l
lJ ' I
r-•I
i1
L_j l ___
I-', f, I,
I , ,: ;
Reviewed by:
Charlie G. Carter Jr., RCE #61968
1 9 8 ll Hom c Av c nu e ♦ San Die is o, C :\ 9 2 I () 5 ♦ (1 1 9 -S 5 0 -l '7 () (J ♦ F ;\ X 6 1 () -5 5 (I -1 7 () 1
-
~· ( I IIZb I IAN WI l[[L[R
r '.J t, I i'-! I 1Z. I '\/ t,
Cc) 1\I PR F S S l VE STRENGTH TEST R LS L' J, TS
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Date Received:
Sampled by:
Tested by:
Sample Type:
Notes:
-
Carlsb,\d \'illa1-;c I .ofts
I 040 Carlsb,HI Village DriYc, Carbbad
\\'crmr:rs Comp;1ni1.:s
Thunder .Jones
I .cvd 1 Column Gridhne 9(~
5000 psi
07-22-20
07-2.1-211
JS
Concn:rt: Cylindt:r 4" x 8"
Date Age
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump:
Min in Mixer:
Dimensions/ Area
22()()13\ Client:
CBRA 2ll20 ()(r:'0 Plan File#:
Architect Ornngt:
\'C\
Hanson
501504
5.19 Ticket#: 8795()6
78° Air Temp: 75°
I" %Air:
.15 Wet Unit Wt:
-----
Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
7986 ()7 29·20 -..J..IHl 12.566 (i\470 5,050 4
7987 ()8 19-20 -4.{Jll 12.566 82,470 6,560 l
7988 08-Jl) 211 28 4.(HI 12.:'iMi :-;n,no 6,430 (,
7989 tl8-l 9•21l 28 4.00 12..16() 82,580 6,570 6
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engmeermg m accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
r:,·anw(c/iwermcrscomp,mics.c(nn
j a \"i cra(i_fjwcrme rscnm panics .com
City of Carlsbad
Suppl1n
' < 1,, D
,,,
Reviewed by:
Charlie G. Carter Jr., RCE #61968
1980 llomc Avenue ♦ San Dicµ;o, C:\ 92]()5 ♦ 6]9-5.S0-17()() ♦ !-'AX (119-SSll-1701
w
L I IIUS I Ii\~ WI IFFI rR
I-'\(, I"\ I-f-R Ir\ f,
C:()"11'1\l:SSl\'I•: STl\1•:l\(;TI! Tl•:ST I\ESL'I.TS
Job Name: ( :arlshaJ \'illagc J ,ofts CWE#: 2200131 Client:
Job Address: 1040 CarbbaJ \'i!lagc Drivt:, Carlsbad Permit#: um .. \ 2020 0070 Plan File#:
Contractor: \X'cm1cr:-. ( :ompanics Architect: .\rchikct ( >rangT
Subcontractor: Thunder Jorn . .:s Engineer:
Test Location: Basement Parking Ramp .\n.:a h>otmg Supplier I lan:--on
(iridlinc .\ 1? 12
Req. Strength: 3000 psi Mix#: 30335771
Date Sampled: 07-13-20 Admixture(s):
Date Received: 07-14-20 Truck#: 59 Ticket#: 877--J.65
Sampled by JS Mix Temp: 78° Air Temp: 720
Tested by: l\S Slump: 5-1 /2" %Air·
Sample Type: ( :oncn.:k C:yltndcr 4" x 8" Min in Mixer: 35 Wet Unit wt:
Notes:
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi)
7839 07-20-20 7 4.00 12.566 .f:'/170 3,790
7840 08-10-20 28 ..J..00 12.566 58.820 4,680
7841 08-10-20 28 -UHi 12.56() 611,110 4,780
7842 08-l0-20 28 4.00 12.566 59,()50 4,700
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering in accordance with the applicable ASTM standards. No
other warranties, express or implied
Distribution
r~·anw(t1;wcrmL·r~c(>mpanic~.c(>m
j:t \' 1c ra (~f;wcrm nsn >m panic~. n 1m
( :ity of ( :arbbad
Supplier
Reviewed by:
Michael 8. Wheeler, RCE #45358
3980 llomc .\vnlUl" ♦ San Diego.(,_\ 9210S ♦ 619-550-1700 ♦ ],'_\X 619-.150-17()1
!N
Cl IIU~TIAN Wll[[l[IZ
I '..J (,IN I ! R IN t,
Co i\l PR LS SI VE STREI\' GT fl TEST RES L' LT S
Job Name:
Job Address
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
(:arlsbad V1llaf,;C Lofts
]04() Carlsbad \'illa~c DriYe, Carlsbad
\\'nmns Cmnpanic~
Thunder Jones
Line C & 2 Lower SOC
2:'iOO psi
U7-tl6-2()
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
22001 _) I Client:
CBRA 2()20 (Hl70 Plan File#:
,\rchitu:t ()rn11,l!;l.
\'CA
flansnn
2S.BSII()
Date Received: (J7-0'7-20 Truck#: 572 Ticket#: 87599:'i
Sampled by: 1),\1 Mix Temp: 8(i0 Air Temp: 78°
Tested by: Slump: 4-1/2" %Air:
Sample Type: Concn.:tc Cylimkr 4" x R" Min in Mixer: 50 Wet Unit Wt:
Notes:
----... -
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
-
7493 ()7 .] 3 2IJ -4.U(J 12.566 24,%0 1,990 (,
7494 08-(!_1.2() 28 4_{)() 12.566 40,98() 3,260 4
7495 nH-03-21) 28 4.(HI 12.566 42,11() 3,350 '
7496 (18-01-20 28 4.00 12..SMl 42,520 3,380 4
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering 1n accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution·
r;i·anw(Cll,wermcrsoimpanics.com
i ,1 v1era(!,Ywcrm crscn rn panics. o lm
( :ity of ( :arlsbad
Supplier
I
I
I
Reviewed by:
[ ..
i _J
•.--,,.,
~''"-"'''''<ct,,-..'"
Michael B. Wheeler, RCE #45358
I/ I
I ' L_...:::
_l 9 8 () Home Av c nu c ♦ San D 1 ego, C ..-\ 9 2 I O .S ♦ 6 l 9 -5 5 fl -I 7 () ll ♦ F ,\ X 6 I 9 -S S (I · 1 7 (I 1
D
~· I IRISTIAN WI lffLrR
f'J(,l'-Jff"RII\:<,
C: O ,\I PR ES S I \' E ST R El\: GT 11 T EST RES L' LT S
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Date Received:
Sampled by:
Tested by:
Sample Type:
Notes:
Sample#
7497
7498
7499
7500
Culslud Village Lofts
104() C:-.rhhad Village Orin:, Carlsbad
\X'cnrn:r., Cumpanic~
Thunder Jone~
Linc D & 7 Lower SOC;
250U psi
07-tl6-2n
()7-07-20
D.\I
NS
Concrete Crlindcr 4" x 8''
Date
Tested/Issued
(}7-1.J,2()
()8-0.1-2()
--
08-0.1-2()
(18-03-20
Age
(days)
-
28
28
28
CWE#
Permit#:
Architect:
Engineer
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump:
Min in Mixer:
Dimensions/ Area
Avg. Dia. (in.) (sq. in.)
... 1-.()(1 12.5(i(i
4_()1) 12.S66
-
4.iHl !2.SM>
4.00 12.566
2200131 Client·
CURA 202!1 007!1 Plan File#:
Arcl1itcct ()rnngL·
\'C\
Hanson
2533500
591 Ticket#: 87(1!1~ I
89° Air Temp: 87°
4" %Air:
7() Wet Unit Wt:
Maximum Load Comp. Strength
(lbs.) (psi) Fracture Type
-
2.),60() 1,880 1
.18,%0 3,100 (,
411,220 3,200 1
---1-1,64(1 3,310 4
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Eng1neenng 1n accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
r!·a n w(ii; we rmersn im panic~ .cc >m
1 ·,1 \. iern(fYwermersn m1 panics. C( lm
c:iry of c:arl~had
Supplier
I
!
I ' LJ
I!
[ '
, I [J LJ I ;I I H
L__,_e
"., ,.._,,,,,.,-,-~ ''"'' ~"' ,.,,.,,,
Reviewed by:
Michael B. Wheeler, RCE #45358
, 9 8 () fl om e ;\\'en u e ♦ San DI e g (), C ,\ 9 2 1 (l 5 ♦ (1 l 9 -.S .SO -l '7 () () ♦ F ,\ X 6 1 9 -5 5 () l 7 () 1
n
,, ...
,c,i,,I
~N
(l lRl~lli\N WHUl[R
r '\J t, I "-.J I l R I l'-< <,
C().\lPRESSIVE STRENCTfl Tl-:ST RESL'J.TS
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
C:nlslud Village Lufts
104() Carlsbad \'illagl'. DriYc, Carlsbad
\\'crmns Compani1.:s
Thunder Jones
Columns ((lf l ,nwer l .e\·el Grid 5-C and (i-C
.SOOO psi
06-2(,-20
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
220lll11 Client:
CBRA 202() 00'7!1 Plan File#:
, \rchitcct Orange
\'CA
Hanson
.1011504
Date Received: 06-29-2(1 Truck#: (iSO Ticket#: K--;4570
Sampled by: RSR Mix Temp: 89° Air Temp: 84°
Tested by: Slump: 5-1 /2" %Air:
Sample Type: Concrete Cy\indr.:r 4" x 8" Min in Mixer: (,7 Wet Unit Wt
Notes:
-~
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
-~-
7297 \P-03-20 ---Uhl 12.%6 ':7,14() 6,140 l
7298 (17-24 21) 28 4.00 12.SMi 89,08{) 7,090 4
-
7299 07-2-1--20 28 4,()() 12.5(li lJ\,4"70 7,280 (,
7300 (P-2-1---2() 28 4.0n [2.566 9(),430 7,200 2
The samplmg, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering m accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
ryan \l;( (~ wcrmcrs com panics .crnn
j ,1 YIC ra (4!,vcrme rsn m1 p:.nie s. com
( :1ty of C:arlsbad
Supplier
! lJ..
I : l
i I u l~j I ,, ' ,H I ' _J I'.,: L_j
,, '.,!,
-~·.'. ·::,~;,' .,,,.,1,.--a;,
Reviewed by:
Michael 8. Wheeler, RCE #45358
1980 Hr)mc J\yenue ♦ S:i.n lJ1cgo, CA 9.21H5 ♦ 619-."iSO-l!OIJ ♦ !'AX ()19-S5(I-170I
'~
I I LJ
-
!N
Cl IRISTl,\N WHlTI.IR
I '\J <,I]\,' 1 I R ! N r,
CO l\l PRESS l VE STRENG T JI TEST RES L' LT S
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Date Received·
Sampled by:
Tested by:
Sample Type:
Notes:
C1rlshad Village Lufts
1040 Carl~bad \'illagc DriYc, Carlsbad
\\'crmcrs Comparn<.:s
Thunder Jones
Spread f.'nntings
:moll psi
06-25-2()
RSR
Cmcrdc Cylinckr 4" x 8"
CWE#:
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
Truck#:
Mix Temp:
Slump:
Min in Mixer:
Dimensions/
22lHl\31 Client:
CHRA 2(120 ()()7() Plan File#:
Archircct Orangc
\'CA
Hanson
30335771
M2 Ticket#: 874224
85° Air Temp: 790
_')" ¾Air:
76 Wet Unit Wt:
Maximum Load Comp. Strength Date Age Area
Sample# Avg. Dia. (in.) (sq. in.) (lbs,) (psi) Fracture Type
Tested/Issued (days)
7305 07-02-20 -4.!Hl 12.566 42,880 3,410 (,
7306 ()7-2.1-20 28 4.00 12.5M1 6),890 5,080 '
7307 07-2.1-21) 2S 4.(Jl) !2.56() ()\17() 5,190 4
7308 07-21-20 28 4.on 12.5Ml 65,740 5,230 2
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering in accordance with the applicable ASTM standards. No
other warranties, express or implied.
Distribution:
ryan w(ll, wcrmerscnm pan ies. C( )tl1
jaYiern(~wermerscnmpanies.U)\11
City of Carlsbad
Supplier
Reviewed by:
Michael B. Wheeler, RCE #45358
I
I
'
·,,~,
<;J,, ,~!,;,,• ,._-,,.
19811 Hom c A\' en u e ♦ San DI cg o, CA 9 2 I (l 5 ♦ 6 1 9 -5 5 (l -I ~ ll O ♦ FAX 6 I 9 -."i ."in 1 7 0 1
I ,
L_J
,,,,,,-.,,, ,,._,, "' ',~· ,.
-
!N
l I IRISTIA"' WI IIH.m
r 'I(, I)\,' r r R IN(,
CO :\IPR ES SI VI·'. STRENG T fl TEST RES LL TS
Job Name: Carlsbad Village Lofts CWE# 22tl0131 Client:
Job Address: 1040 Carl~bad \'11lagc Dri,·c, C:arlsbad Permit#: CBRA 202() 007(1 Plan File#:
Contractor: \\'crmcrs Companies Architect: ,\rchirccr Ornngc
Subcontractor: Thunder Jones Engineer: \'C\
Test Location: Co!umns@Lmver Level Grid AC-1 & D.S-1 Supplier: Hamon
Req. Strength: SOOll psi Mix#: SOl 15114
Date Sampled: Admixture(s):
Date Received: Truck#: (A() Ticket#: 874181
Sampled by: RSR Mix Temp: 83' Air Temp: 74°
Tested by: Slump: % Air:
Sample Type: Concrete Cy!inlkr 4" x 8" Min in Mixer: 75 Wet Unit Wt·
Notes:
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
--'
7301 07-02-20 -4.00 12.566 65,210 5,190 6
7302 07-2.1-20 28 4.00 12.5(16 Kl,840 6,510 1
----,-
7303 07-2.1-21) 28 4.0() 12.566 8.\570 6,650 1
7304 iP-23-20 28 4.0!l 12.56() 8.S,ll60 6,770 4
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engineering in accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
ry,1 n w(il.i,we rmcrscom panics. C( 1m
j,1,·icrn(l_l}wcrmcrscc1mpanies.com
( :ity (lf ( ::1rlsbad
Supplier
L .-L_j l r·--, IJ lJ '
1-' ·.1!
!1_·,,'-.,
_;_1_u ~
,.~_,, •~,, C ,, "·-"''"-'·"'"
Reviewed by:
Michael B. Wheeler, RCE #45358
.19811 Home A,-cnuc ♦ San Diego, C:\ 92105 ♦ 619-550-[7()1) ♦ F1\X 619-S.Sll-[7()\
[J
,.,,i,,,,,
--
!N
Cl IRISTIA '\J WI l[[L[R
I ,, <,IN I I R Ir-..; t,
CO;\[PRESSIVE STRENCiTH TEST RESL'J.TS
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled
Carlsb,HI Village I .ofts
I 040 Carhbad Village Orin:, Carlslwl
\\'crmcrs Comp;mics
Thunder Jones
I .inc C / 6 Spread Footing
JOOIJ psi
06-24-2ll
CWE#:
Permit#:
Architect:
Engineer·
Supplier:
Mix#:
Admixture(s):
2200131 Ctient:
CBRJ\ 2020 0070 Plan File#:
Architect Orange
\'CA
Hanson
3()335771
Date Received: 06-25-20 Truck#: (J.l.) Ticket#: 873%5
Sampled by: rnr Mix Temp: 84° Air Temp: 730
Tested by: NS Slump: I" ¾Air:
Sample Type: Concrete Cdindcr 4" x 8" Min in Mixer: 75 Wet Unit Wt·
Notes:
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (psi) Fracture Type
7190 07-01-20 -4.00 12.566 45,64() 3,630 5
7191 (17-22-20 28 4.00 12.566 64,9()() 5,170 1
7192 07-22-20 28 4.00 12.5U) ()2,1.10 4,940 <,
7193 fP-22-20 28 4.00 12.566 63,740 5,070 3
The sampling, handling, cLinng and compressive strength testing were performed by Christian Wheeler Engineering in accordance with the applicable ASTM standards No
other warranties. express or implied.
Distribution:
ry:1nw(tJi,wermcrscompanics.cnm
j J. \·1era(qJwcrm crscom pan i es. com
City of Carlsbad
Supplier
I
I
~-LJ '
I ' L_J 8 [l r-~ I -
" I ' I ' ·~ .L ,.~-,
,, ''"'""''·'"'7"'
'""""'"''
Reviewed by:
Michael B. Wheeler, RCE #45358
1 9 8 O Home Avenue ♦ San Di cg o, Ct\ 9 2 I () 5 ♦ 6 l 9 -S _=; !l -I 7 lJ O ♦ l; AX Ci I 9 -5 5 () -l 7 0 l
D
.,._-,,
w
CHIUillAN WHffUR
l 'J (, I ~ I I H. I "-J (,
C O i\l P R ES S I V E ST R EN GT H TEST RES l 1 LT S
Job Name: CWE#: 22tl01.'i l Client:
Job Address: 104U \.arl<;bad Village Orin:, Carlsbad Permit#: CBRA 2020 007(1 Plan File#:
Contractor: \X'crmcts Companie::. Architect: Architect Orangc
Subcontractor: Thunder Jones Engineer: \'CA
Test Location: Le\·el 8 -Cnlumn (j_~ GI. ]()fl Supplier: Hanson
Req. Strength: SOOU psi Mix#: SOI 1504
Date Sampled: 06-23-2() Admixture(s):
Date Received: 06-25-211 Truck#: ().)_'i Ticket#: 87.174.)
Sampled by: JS Mix Temp: 78° Air Temp: (18°
Tested by: NS Slump: I" %Air:
Sample Type: Concn:tc Cylindcr 4" x 8" Min in Mixer: _'IS Wet Unit Wt:
Notes:
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs,) (psi) Fracture Type
7153 06 30-20 " --l-.00 12.566 7S,21ll 5,990 \
7154 07--21 --20 28 4.00 12.566 9.1,H-::'0 7,470 1
7155 07-21-20 28 4.(Hl l2.5Mi 91,220 7,260 4
7156 (17 .. 21--20 28 4.00 12.566 94,670 7,530 3
The sampling, handling, curing and compressive strength testing were performed by Christian Wheeler Engmeenng m accordance with the applicable ASTM standards. No
other warranties, express or implied.
Distribution:
ry,rnw(d,wermerscompames.com
i ,1 dern(q)werme rscumpanie s. c< lm
City of Carlsbad
Supplier
I
I ' i_J
I! 1--
l ,; I
l'J
Reviewed by:
[
Michael B. Wheeler, RCE #45358
.19 HO Home A\' c nu e ♦ San Die g 1), C ,..\ 9 2 1 0 5 ♦ 6 I lJ --5 5 fl . 1 7 ll 0 ♦ Fi\ X 0 I 9 --5 5 ll --l 7 0 1
,,. '.,,·,,.,,.,.,1,
----
City of Carlsbad
JUN 2 5 2020
BUILDING DIVISION
w
Cl IRISTIAN WI IFH.ER
! '-J (,Ir\ I I It Ir'\(,
RECORD COPY
I; I 1: I D RF PORT
Project Nan1e Carlsbad Village Lofts CWE# 2200131 Date: (i/22/20 I Page 1 of 1
Project Address 1040 Carlsbad Rl, Carlsbad Ca. Permit# <:RR 20200070 Project File #
C011tractor \X'cnners Companies Architect ,-\()
Sub'-·011tr,1ctor 'llmndcr.J(111es Engineer \'CA
(3J !{cmforccJ ( :oncrctc □ l'rc-StrcsscJ Concrete □ Rcmt!m:cJ :-.lasomy □ Epoxy ,\nchors □ Shop WdJing □ FtdJ WdJmg
□ I hgh Strength Holts □ N<>n-Dcstrnctn·c ·1·c::~ting □ l\fcch:m1rnl :\nchors □ !<'irqmu,ting □ \VooJ/\ktal Sheir □ \VarcrpnJtifinl-\
□ Footing ( )bscr-.:ation □ ,\sphall ( )bs/Tt:stmg □ Soil Ob.,/Tesrmg □ Rriofing □ Build,ng J;,mTllipc □ ITS <;rout
ftfatcrial/Equipnrcnt: ,-\615 (iradc 60 Rebar. flanwn concrete# 30335771-3000 psi
Arrived on site, as requested, to provide the following services:
Spccial Tnspcction of the placement of concrete at the lower Lcn:1 R penmctcr north footing along ( iridhne 9 to 11, column footings at ( ;ridlinc 1 0C,
I IC, 2D, 3D, 2F, 3E, 21', 31<', 3G 411. Rebar installed, footings free of dchris, clearances to rebar good. Ground water \Vas pumped out of footings.
Concrete was boom truck pumped, consolidation donc by mechanical v1bration. One set of 4x8 inch cylinders made for strength testing. ,\lso inspected,
same kvel-shotcrete wall \X'-1 rebar alc)ng (iridlinc 11 from II to south comcr, along (indlim: 14 fromJ to D, along (i1idline D from 14 to 12, and
(;ridhne 12 from D to I :. Work done in general conformancc with thc plans.
NOTED DISCREPANCIES -The itcms noted below werc obscrved to be in non-confonnancc with the approved project documents and will rc4wre
corrccrion or the design enginccr's revic..'W for approval:
,, "
NOTICE: Unless otherwise stated, the ,.,:ork ohsen-ed was, to the best of my knowledge, in complianct with tht appro,·ed projtct docu111cms. It should be noted that tht
work reported as being obstn-cd, ttstcd, and opmions expressed atl' soldy for the benefit of our client :md that our prescnct and the sctTn;cs prm·ided do not rdien' the
contractor from its obligatmn to meet conrractual rc4mrements.
~ N,. 11_. John Shirley San Diego 1074
l Te:hnician's s/natllre /m;pector/Technician Name Certification #
Initial Distnbution: javiera@wcnnerscumpanies.cc)m
Reviewer Name Certification # Reviei.ver'r.· Signature
Rt:l'it:i.ved Distribution:
3980 llomc ,\vcnU(' D San l)icgo, (:,\ 92105 D 619-550-1700 D l',\X 619-550-1701
!N
Cl IRISIII\N WIIULIR
I '\J (, I 1's f [ RI r-,..' (,
C O :,.,1 P R ES S l VE ST R ET\: GT H T EST RES l' LT S
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Car\sb,1d Villaµ;i.: Lofts
104() Carlsbad \'illagc Orin:, Carlsbad
\X'crmns Companies
Thunder Jones
l.cn:l 8-Column Fnnting-GI, JOC
3ll!l0 psi
ll6-22-W
CWE#
Permit#:
Architect:
Engineer·
Supplier:
Mix#:
Admixture(s):
220013! Client:
CHRA 2020 0070 Plan File#:
Arch1tcct ( )rangL:
\'CA
I lan~nn
30335771
Date Received: 06-2."-20 Truck#: 5811 Ticket#: 871514
Sampled by:
Tested by:
Sample Type:
Notes:
Sample#
~-
7103
7104
7105
7106
IS
l\'S
Concrete Cylinder 4" x 8"
Date
Tested/Issued
-· -
06-29-2()
07 -21! 20
07-2!1-20
(P-20-20
~
Age Dimensions/
(days) Avg. Dia. (in.)
" 4.()()
28 4.UO
28 4.00
28 4.0ll
Mix Temp: 78' Air Temp: 68°
Slump: S" %Air:
Min in Mixer: 15 Wet Unit Wt:
Area Maximum Load Comp. Strength
(sq. in.) (lbs.) (psi) Fracture Type
12.56() 50,47() 4,020 (,
12.56() 66,020 5,250 ' --·--
12.56() (i4,880 5,160 (,
[2,566 (i6,3Ml 5,280 4
The sampling, handling, curing and compressive strength testing were performed by Chnst1an Wheeler Engmeenng m accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
ry,,1nw(i.i1wcrmcr~n1mp,m1es.cnm
i a\" i er ,1@wermerscom p,1 n ies. cnm
(:ity of ( :arlshad
Supplier
' I ~--1
,,
ii Li L_
Reviewed by:
T,~o•
~'''-"'"'''' ''·" •''"
Michael B. Wheeler, RCE #45358
1980 Home Avenue ♦ San DicgrJ, CA 92105 ♦ 619-550-!7()() ♦ FAX 619-5511-!701
w
Cl IRl,TIAN Wf II.ILi R
I '-t, IN I l R I 'J <,
C O ~I PRESS I V E ST R E 1' GT II T EST R ES L' I.TS
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Carlsbad Village Lofts
]()40 Carlsbad Village Dri\·c, Carl~bad
\\'crmcrs Cumpatm.:s
Thunder Jones
Formed Columns (if; Lower I ,cvcl, I lea
.SOIJU psi
CWE#
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
2200131 Client:
C8RA 2020 0070 Plan File#:
Architect Orangl·
\'CA
I lanson
.S0!]5()4
Date Received· llG-!9-W Truck#: S72 Ticket#: 872980
Sampled by:
Tested by:
Sample Type:
Notes:
Sample#
7050
7051
7052
7053
RSR
NS
Concrete Cylimkr 4" x 8"
Date
Tested/Issued
06-25-20
07-16-20
07-16-20
07-16-20
Age Dimensions/
(days) Avg. Dia. (in.)
" 4.llO
28 4.UO
28 4.0ll
28 4.00
Mix Temp: 83° Air Temp: 7()0
Slump: 5" %Air:
Min in Mixer· 56 Wet Unit Wt:
Area Maximum Load Comp. Strength
(sq. in.) (lbs,) (psi) Fracture Type
12.566 61,000 4,850 6
12.566 86,9!0 6,920 1
12.566 87,400 6,960 2
12..16() 85,310 6,790 4
The samplmg, handling, curing and compressive strength testing were performed by Christian Wheeler Engmeenng ,n accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
ryanw((Ywermcrscompanies.com
jaYiern@wcrmersoJmpanics.cnm
Cin· of CarlsbaJ
Supplier
I! I,
i '
L J r D ,J lJ
' 1, ;_\!
i1 1,'1·_'·, LJ ' ~JJ,-'
',~,.· \'col-',,n,~,,~,.,, ••• ,!0;<,,.,,~1
Reviewed by:
Michael B. Wheeler, RCE #45358
)9811 flome Avenue ♦ San Diego, Cr\ 921115 ♦ 6!9-550 170() ♦ l'AX 619-550-1701
D
!N
CHR l:iTIAN WI IFCLSR
I ".' (, I N I I K. I N <,
COMPRESSIVE STRENGTH TEST Rl'.Sl'LTS
Job Name:
Job Address:
Contractor:
Subcontractor:
Test Location:
Req. Strength:
Date Sampled:
Carbbad Village Lofts
1040 Carlsbad \'illagc Drive, Carlsbad
\X'umcrs Companies
Thunder Jones
3()0() psi
06-l8-2ll
CWE#
Permit#:
Architect:
Engineer:
Supplier:
Mix#:
Admixture(s):
220()131 Client:
CHRA 2020 0070 Plan File#:
Architect Orange
\'CA
I-Linson
30335771
Date Received: ()(,-! 9-2(1 Truck#: 572 Ticket#: 872880
Sampled by: RSR Mix Temp: 8U0 Air Temp: 77°
Tested by: Slump: 5" ¾Air:
Sample Type: C:oncrctc Cylinder 4" x 8" Min in Mixer: 70 Wet Unit Wt:
Notes:
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs,) (psi) Fracture Type
7046 06-25-2() " -1-.00 12.56(1 41,120 3,430 4
7047 ()7 16-20 28 4.Ull 12.S66 64,550 5,140 '
7048 117-16-20 28 4.00 12..SM> 62,880 5,000 (,
7049 07-16-20 28 4.00 12.S66 64,170 5,110 ' The sampling, handling, curing and compressive strength testing were performed by Chnst1an Wheeler Engineering m accordance with the applicable ASTM standards. No
other warranties, express or implied.
Distribution:
ry,1nw(ll;wcrmcrs c< im panie s. C< im
jadern(c{!wcrmerscompanies.cnm
City of Carlsbad
Supplier
Reviewed by:
Michael B. Wheeler, RCE #45358
.1980 Home ,.\\'enue ♦ San Diego, C/\ 92105 ♦ (119-551l-17ll0 ♦ FAX 619-SSll-1701
w
U IRIST!i\N WI IEELER
1 '-Cl'<l-1-Rlr-._(.
C:O,\IPRl·'..',SJ\'1,'. STREJ\:(;TI/ TFST RE,'.-;lll.TS
Job Name: C::1rbh:1d \'illagl'. Loft:-CWE# 2200131 Client:
Job Address: Permit#: ( :H 20200070 PJan File#:
Contractor: \X'ermcrs ( :om pa nil's Architect: .\rchitcct ( )range
Subcontractor: Thunder Jones Engineer: \'<:.\
Test Location: J,cvcl B (;B-6, (;ridlinc .\ ({j: 7.5 Supplier: I lan:-on
Req. Strength: _)()()() p:--i Mix#: 30.130771
Date Sampled: 06-05-20 Admixture(s):
Date Received: 06-08-20 Truck#: 633 Ticket#· 870243
Sampled by: JS Mix Temp: 78° Air Temp· 720
Tested by: '.\JS Slump: )" %Air:
Sample Type: ( :0111..:rctc { :Ylimkr 4" x 8" Min in Mixer: 35 Wet Unit Wt:
Notes·
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in.) (lbs.) (pst) Fracture Type
6693 06-12-20 7 4.UU 12.566 46,040 3,660 6
6694 07-03-20 28 4.00 12.566 66,940 5,330 4
6695 07-03-20 28 4.00 12.S66 64,760 5,150 3
6696 07-0.)-20 28 4.00 12.566 64,110 5,100 3
The sampling, handling, curing and compressive strength testing were performed by Chr1st1an Wheeler Engineering 1n accordance with the applicable ASTM standards No
other warranties, express or implied.
Distribution:
r~·an,v(t1)wcrmcrsc11mpamcs.n1m
ja vicra(dwcrn1crsc( )m pa 11 ic~ . C( J m
( :ity of ( :arlsbaJ
Supplier
L __ _
v,",,,,,,,
PC" ,N""O,,•,•n•,·,,.,-n,; "',w,r,.a,0 ,,,,.,11 ,,,,,,,.0,,,,,,,, , .. ,,
Reviewed by:
Michael B. Wheeler, RCE #45358
3980 llomL· .\venue ♦ San Dtcgo, C:,\ fJ210:l ♦ 619-SS0-1700 ♦ 1-'.\X 619 550-1 7 01
w
l I IIUSTIAN WI IU:1.tR
r '-(,I~ 1-FR I"\(,
CO.\IPH.LSSl\'E STRET\j(;TII TEST RESLII.TS
Job Name: Carlsbad \'illagc Lofts CWE#: 2200131 Client:
Job Address: 1040 C:arbbaJ \'illagt· Drive, Carlsbad Permit#: < :B '.W200070 Plan File#:
Contractor: \X'cnrn:r:--( :ompaniL·s Architect: . \rch1tcct ( )range
Subcontractor: 'l'hundn_Joncs Engineer:
Test Location: Lewi H -c;B-2, c;ridlmc 5 ~t'; I'. Supplier: I lan:--on
Req. Strength: .1000 psi Mix#: 30330771
Date Sampled· 06-05-20 Admixture(s):
Date Received: 06-08-2() Truck#: 650 Ticket#: 870311
Sampled by: JS Mix Temp: 770 Air Temp: 720
Tested by· NS Slump: 4-1/2" %Air:
Sample Type· ( :oncrctc ( :ylindt:r 4" x 8" Min in Mixer: Yi Wet Unit wt:
Notes·
Date Age Dimensions/ Area Maximum Load Comp. Strength
Sample# Tested/Issued (days) Avg. Dia. (in.) (sq. in) (lbs.) (psi) Fracture Type
6697 06-12-20 7 4.00 12.566 42,910 3,420 5
6698 07-03-20 28 4.00 12.566 61,990 4,930 3
6699 07-03-20 28 4.00 12.566 60,440 4,810 4
6700 07-03-20 28 400 12.566 19,660 4,750 3
The sampling, handling, cunng and compressive strength testing were performed by Chnst1an \1\/l)eeler Engineering in accordance with the applicable ASTM standards No
other warranties, express or implied
Distribution:
rya n w(ii: we rm crsc c im pa mt.:s. cc nn
ja v icrn (l1)wcrnwrse< )Ill pan il ·:,;. cc 1m
(:ity (lf(:arlsbaJ
Supplivr
).
V . L_I
·,,,.,: i,,.j.',,,,,.,,,,,,e.•o,w-
~""\' ,'1" e-,-," ' .. ,,,,,,, ~ "'
Reviewed by:
Michael B. Wheeler, RCE #45358
3 9 8 0 11 o tlH" .\ v c nut.: ♦ ~ a 11 l) i cg o, C .\ 9 2 1 0 "l ♦ 6 1 9 -S SO -1700 ♦ I_..\ X 6 1 9 -5 SO -1 "7 () 1