Loading...
HomeMy WebLinkAbout1819 ASTON AVE; ; FPC2021-0243; PermitPERMIT REPORT Fire Permit Print Date: 06/16/2022 Job Address: 1819 ASTON AVE, CARLSBAD, CA 92008-7338 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel#: 2121201100 Track#: Valuation: $0.00 Lot#: Occupancy Group: Proj ect#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: (city of Carlsbad Permit No: FPC2021-0243 Status: Closed -Fina led Applied: 12/29/2021 Issued: 01/11/2022 Finaled Close Out: 06/16/2022 Final Inspection: INSPECTOR: Robinson, Jarrod Cheung, Nathaniel Description: JETT AND JONES LLC -ADD WIRELESS TRANSMITTER & RECEIVER TO MONITOR DEVICE (UNDERGROUND CONDUIT WIRE TO 0 WAS DAMAGED) Applicant: BAY ALARM COMPANY DAN ANDERSON 8205 RONSON RD, # STE F SAN DIEGO, CA 92111-2014 (618) 718-0186 FEE FIRE Plan Review (per hr -Regular Office Hours) FIRE Sprinkler Monitoring Add'I Inspection Total Fees: $372.50 Total Payments To Date: Fire Department $372.50 FPContractor: BAY ALARM COMPANY 8205 RONSON RD, # STE F SAN DIEGO, CA 92111-2014 (858) 586-3803 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov AMOUNT $223.50 $149.00 $0.00 Page 1 of 1 .. RECEIVED FPC2021-0243 1~ ;!~o~~~Lt ~A';D WIRELESS TRANSMITTER & r ''l~cn'7J CARLSBAD Pir~Permtt: Application RECEIVER TO MONITOR DEVICE 2121201100 12/29/2021 Prolect Information FPC2021-0243 B j t N JETT & JONES LLC. rroe, ame ~---~~------------------- ProJ ctAddr ss 1819 ASTON AVE Sult # ______ _ REVISION AT 1819 ASTON AVE. ONLY: U/G CONDUIT WIRE TO OS&Y WAS DAMAGED. Scope of Work AOC WIRELESS TRANSMITTER & RECEIVER TO MONITOR DEVICE, AHOClated Oulldlns Permit# (If applicable) ~'>' ~{ ,s. ~lM,\l. ~CT !:fts1 ~1 G~ ~/'f1~ ffC'LDl'\-02.~0 □ Fire Sprinkler Sy1t:em: Number of risers ____ Number of Heads ___ _ D Under1round: Numb r of Hydrants __ _ □ FlroAlarm Iii Sprinkler Monitorlna Cl NowSystcm □ Tenant lmprovomtmt □ Other: __________ _ contractor Information CO N BAY ALARM CO. mpanv am@ _______________________ _ Addr 5 8206 RONSON RD., SUITE F City SAN DIEGO St CA ZI 92111 ata _ p __ _ A II N DAN ANDERSON pp cant ame _______________________ _ Phon 619-718-0186 Email DAN.ANOERSON@BAYALARM.COM #880138 C-10 E O 06/30/22 COmr@ctor Llccnte Numb r and Typ _____________ xp. at __ _ 1229936 City Business License Number ____________________ _ For qu111tlon5 about the appllcatlon 6Ubm1ttal package please email; f Ire Permit Techn1clan Flro Prevontlon I 1635 Faraday Ave I carlsbad, CA 92008 I 760~602-4660 I www.carlsbadflre.ors 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 4 70-1000 Contractor License# 880138 I. PROTECTED PREMISE IL JETT & JONES LLC FACPROOM 1819 ASTON AVE CARLSBAD, CA 92008 MONITORING COMP ANY Bay Alarm Company 5130 Commercial Circle Concord, CA 94520 800-4 7 0-1000 California Alarm Operating License Number: ACO28 III. EQUIPMENT SUPPLIER & INST ALLER 8205 Ronson Road, Suite F San Diego, CA 92111 1 (800) 470-1000 Contractor License # 880138 -..,.--~ DMP.COM O C) E). (;) C) @ DMPALARMS ~ill~ • Powerful addressable fire alarm control panel (FACP) • Proven reliability suitable for commercial and industrial installations • Full range of zone expansion, communication, and relay output capability • Flash updatable -locally over cell or network • Onboard digital dialer, network communicator or optional cellular communicator XR150FC/XR550FC FACP • Up to 562 two-wire smoke • Eight communication paths detector or fire initiating between the panel and zones on XR550FC central station ► Up to 142 two-wire smoke ► Built-in remote or detector or fire initiating on-site firmware zones on XRlSOFC upgrade capability ► Up to .5 Amps 12 VD( • 12,000 event buff er smoke and auxiliary output with OVC protection • French, Spanish and English menus available ► Up to .7 Amps 12 VD( supervised bell output ► Multiple onboard status LEDs ► Up to 506 fully ► Up to 100 output schedules programmable Form C relays to control relays and panel outputs ► Serial 3 Digital Dialer or CID ► 32 individual reporting reporting to multiple receivers areas with common areas ► Built-in 32-cha@cter LED annunciator on panel door ► Output groups deliver maximum functionality with easy programming Onboard Network ► Onboard 10/100 autosensing Ethernet or Wi-Fi connection • Customizable check-in time and retry time • Suitable for multi-site applications OUTPUTS The XR150FC and XR550FC allow the use of two SPDT relay outputs and four open collector outputs, which may be activated by zone or system events, by schedule, through the User Menu, or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched-ground outputs. STATUS LIST To provide maximum system flexibility, fire zones may be programmed to display at a specific keypad. In this manner, all fire zones can be monitored in one location, and other zones can be programmed to display and be monitored at different keypad locations. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft"' Windows'". The XR150FC and XR550FC panels include an interface connection for installers to use to connect a laptop computer. COMMERCIAL WIRELESS FIRE DEVICES The list of DMP wireless devices that have earned the UL Commercial Fire Listing include: 1103 Universal Transmitter: Two-input transmitter typically used in commercial burglary door or window applications. llOOR Wireless Repeater: Extends the communication range of DMP receivers, enabling physically larger, more reliable wireless security systems. llOOX Wireless Receiver: The llOOX Receiver supports up to 500 transmitters and satisfies all wireless applications. 1100XH High Power Wireless Receiver: Provides additional transmit and receive amplification for improved performance at greater distance or in harsh building environments. Commercial Smoke Detectors: The 1164 includes synchronized sounders, and a tamper switch. The 1164NS is for applications with existing sounder/ notification devices. 1183 Wireless Heat Detector: The 1183 Series is a reliable, ceiling-mount heat sensor available in two versions. The 1183-135F responds if the temperature exceeds 135°. The 1183-135R adds a rate-of-rise feature that responds if the temperature increases by 15°F per minute or more. 1184 Carbon Monoxide Detector: The 1184 Carbon Monoxide Detector is the ideal choice for difficult-to- wire locations, applications where room aesthetics are critical, or where hazardous materials are present. The sensor provides an early alert of potentially harmful levels of carbon monoxide in residential or commercial installations. In addition, it also transmits trouble, tamper, and low-battery messages to the panel. 1164-W Commercial listed Smoke Detector Mini-llorn I J' . .,.:': * • Motor Bell I 1183·135R Wireless Rate of Rise Heat Detector 1103-W Universal Transmitter ' ' ' I '11----1 .,.,~?"'""'" Strobe Horn Strobe •• Sync Module Sync Module I 865 866 867 1184-W Wireless Carbon Monoxide Detector Power Supply 1103-W 850S Universal Transmitter Manual Fire Alarm Pull Station \·------------------------------· llOOR·W XRSSODNFC 711 Zone Expansion Module llOOXH-W Remote Annunicator 715-8 or 715-16 Zone Expdnsion Module 6.8 Power Requirements During AC power failure, the XR150FC/XR550FC Series panel and all connected auxiliary devices draw their power from the battery. All devices must be taken into consideration when calculating the battery standby capacity. The following table lists the panel power requirements. You must add the additional current draw of keypads, zone expansion modules, smoke detector output, and any other auxiliary devices used in the system for the total current required. The total is then multiplied by the number of standby hours required to calculate the total ampere-hours required. Standby Battery Power Calculations XR150FC/XR550FC Series Control Panel Relay Outputs 1-2 (ON) Switch Grounds 3-6 (ON) Active Zones 1-8 Active Zones 9-10 2-Wire Smoke Detectors Panel Bell Output 893A Dual Phone Line Module 263C CDMA Cellular Communicator 263H HSPA+ Cellular Communicator 277 Buzzer Module 11 00X Wireless Receiver 1100XH Wireless High Power Receiver 860 Relay Output Module (one relay active) All four relays active 865 Style Y or Z Notification Module 866 Style W Notification Module 867 LX-Bus Style W Notification Module 869 Dual Style D Initiating Module 630F Remote Fire Command Center 7060/7160 Thinline/7060AAqualite Keypad 7063/7163 Thinline/7063A Aqualite Keypad 7070/7170 Thinline/7070A Aqua lite Keypad Active Zones (EOL Installed) 7073/7173 Thinline/7073A Aqualite Keypad Active Zones (EOL Installed) 7872 Graphic Touchscreen Keypad Active Zones (EOL Installed) 7873 Graphic Touchscreen Keypad Active Zones (EOL Installed) 734 Wiegand Interface Module Active Zones (EOL Installed) Annunciator (ON) 734N Wiegand Interface Module Active Zones (EOL Installed) Annunciator (ON) Wiegand Reader Copy Sub-Totals to next page *Based on 10% of active zones in alarm. Digital Monitoring Products 10 Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Qty Standby Current Alarm Current 1 X 174mA ---1.Z.1._mA Qty 1 X 217mA ....11LmA 30mA --Qty 30mA --5mA --Qty 5mA --1.6mA --Qty 2mA* --4mA --Qty 30mA --0.1mA --Qty 0.1mA --1500mA __ mA X 12mA --Qty X 50mA __ X 13mA --Qty X 13mA -- X 24mA __ Qty X 28mA -- X 5mA --Qty X 5mA -- X 46mA --Qty X 46mA -- X 160mA --Qty X 160mA -- X 34mA --Qty X 34mA --138mA --138mA -- X 26mA --Qty X 85mA -- X 45mA --Qty X 76mA __ X 30mA --Qty X 86mA -- X 25mA --Qty X 75mA -- X 63mA --Qty X 92mA -- X 72mA __ Qty X 80mA -- X 85mA --Qty X 100mA -- X 72mA __ Qty X 87mA __ 1.6mA __ Qty X 2mA* __ X 85mA --Qty X 100mA --1.6mA --Qty X 2mA* -- X 145mA __ Qty X 215mA --1.6mA __ Qty X 2mA* __ X 143mA --Qty X 243mA --1.6mA --Qty X 2mA* -- X 15mA --Qty X 15mA __ X 1.6mA --Qty X 2mA* --Qty X ZOmA __ X 146mA --Qty X 148mA __ X 1.6mA --Qty X 2mA* --Qty X 20mA -- X 200mA --Qty X 200mA -- Sub-Total Standby __ mA Sub-Total Alarm __ mA XR 150FCI XR550FC Series Installation Guide ~--~ DMP.COM o o e o o o @DMPALARMS iiiir"illliii'- Digital Cellular Communicators ► Plug-and-play installation ► Can be equipped with local or ► DMP Adaptive Technology'" and activation of add-on remote antenna switches communication communication modules paths while maintaining ► Check signal strength supervision if the current ► Direct reporting to any indication at the keypad path becomes unavailable on DMP monitoring center ► Supports the DMP Virtual the XR Series'" panels receiver with no relaying or intermediary retransmission Keypad'" app ► 263EXT Cellular Extension of alarm signals ► XRSS0E provides privacy Modules extend cellular reach ► Power from panel with low for your data with DMP up to 300 feet using a single encryption technology wired connection without current draw for long standby losing dB strength battery life ► XRlS0FC/XRSS0FC with 263 ► Fully supervised to ensure Series communicators have communication FDNY approval for network or cell primary communication SECURITY SIGNALING ® LISTED Simple Expansion Solutions Expand your DMP panel options with a wide array of expansion modules. • Add supervised Class B burglary zones. • Connect non-powered burglary or fire type devices for intrusion, glassbreak, and motion detection. • Add 12 VDC zones for addressable 2-wire smoke detectors with 715 modules. ZONE EXPANSION MODULES: ZONE EXPANSION MODULE FEATURES • Provides Class B zones for burglary and fire • Compatible with DMP Panels that allow zone expansion • Suitable for mounting near protection devices • Connect devices using 4-wire bus • Easily mount attractive cases on wall or 3-gang box • Compatible with all panel zone types' • ~sy connection to 4·wire 15eypad -0r lX~aus 1111 % ,, l , , ,,; T • Proven design ensures stability and performance • Data LED on zone expander indicates good panel communication • Durable and attractive plastic or metal housing • Low current draw , • Can be powered f,r~m panel or auxiliary power supply 714/71S ZONE EXPANDERS The 714 contains four Class B burglary zones and is suitable for use with burglary and fire devices that are normally opened or normally closed. Individual zones are supervised with 1 k Ohm EOL resistors and can be programmed with any burglary or fire zone type. The 715 contains four Class B powered zones and is suitable for use with 12 voe, 2-wire smoke detectors and non-powered fire or burglary devices. Individual zones on the 715 are supervised with a 3.3k Ohm EOL resistor and can be programmed with any burglary or fire zone type. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 718T Plug-in Screw Terminal. The enclosure can also accommodate the 719T Terminal Boards for the 714 or the 720T Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1 K EOL resistors are included with the 719T and 3.3K resistors are included with the 720T. 714/71 S FEATURES • Four protection zones on each module • Comes with 12-conductor wire harness • Optional 12-position screw terminal 714-8, 714-16, 71S-8,AND 715-16 DESCRIPTION The expanders are housed in a Model 340 locking metal enclosure suitable for mounting in a remote location. Each expander provides screw terminal strips for zone inputs and data bus connections, a two position jumper to designate connection to the keypad bus or the LX-Bus, and an LED to indicate communication with the panel. Separate zone End-of-Line resistors are included with each expander. 714-8/714-16 EXPANDERS The 714-8 Expander contains 8 Class B zones. The 714-16 Expander contains 16 Class B zones. Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1 k Ohm EOL resistor and can be programmed as any zone type. 71S-8/71S-16 EXPANDERS The 715-8 Expander contains 8 Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 voe 2-wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3k Ohm EOL resistor and can be programmed as any zone type. 714-8, 714-16, 71 S-8, AND 71 S-16 FEATURES • 8 or 16 protection zones per expander • Durable metal enclosure housing with lock and key T • Individual screw terminals accommodate 14 to 22 gauge wire for easy connection • Suitable for mounting in a remote location 71 I DESCRIPTION The 711 Zone Expansion Module connects to the panel's 4-wire Keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. ~•'' . ' ~: .~ * ~f ·;: .. ~ ~ V. ,..,,. 0 • ..,_. -'= - 71 I FEATURES • Single-zone expander • Rugged screw terminals accommodate 14 to 22 AWG • Board fits in Radionics POPIT housing • Easy rotary switch addressing - Contents ZONE EXPANSION MODULE FEATURES 1 USE ON THE DMP LX-BUS™ 2 CONNECT TO KEYPAD BUS 2 SIMPLE ADDRESSING 2 EASY INSTALLATION 2 ZONE PROGRAMMING 2 708 BUS EXTENDER MODULES 2 710/710F BUS SPLITTER/REPEATER MODULES 2 712-8 ZONE EXPANSION MODULE 2 712-8 FEATURES 2 714/715 ZONE EXPANDERS 3 714-8, 714-16, 715-8, AND715-16 DESCRIPTION 3 725 24 VDC EXPANSIONMODULE 3 711 DESCRIPTION 3 711 FEATURES 3 ZONE EXPANSION MODULE COMPARISON CHART 4 MODULE SPECIFICATIONS 4 LISTINGS AND APPROVALS 4 (-jj Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i' Series model number_ listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W·B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135'F (57.2°(). The detector shall include a mounting base for mounting to 31/,--inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster 1ing, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent pedoot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT·B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module. 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Maximum Ripple Voltage Standby Current Maximum Alarm Current Peak Standby Current Alarm Contact Ratings Physical Specifications Dimensions (including base) Weight Operating Temperature Range Operating Humidity Range Thermal Sensor Freeze Trouble Sensitivity Input Terminals Mounting Nominal: 12/24V non-polarized Minimum: 85V Maximum: 35V 30% peak to peak of applied voltage 2-wire: 50 µA maximum ave1age; 4-wiie: 50 µA maximum average 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA@ 24V 2-wire: 100 µA; 4-wire: n/a 2-wire: n/a; 4-wile: 0.5 A@ 30V AC/DC 5.3 inches (127 mm) diameter; 2.0 inches (5 i mm) height 6.3 oz. (178 grams) 2W·B and 4W·B: 32'F-120'F (D°C-49'C); 2WT·B and 4WT-B: 32°F-1 OO"F (0'C-37.8°() 0 10 95% RH non-condensing 13s•F (57.2°C) fixed 2WT-B and 4WT-B only: 4 I •f: (5°() 2.5%/ft. nominal 14-22 AWG 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a pla~1e1 ring Direct mount to ceiling LEO Modes Power Up Sequence for LEO Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 1 O seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 secoMs off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 1 0 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-8 No 2-wire 2WT-B Yes 2-wire 4W-B No 4-wire 4WT-B Yes 4-wire Accessories 2W-MOD2 2-wire loop test/ maintenance module RT SENS-RDR Sensitivity reader ~~SYSTEM C~ SENSOR" A77-AB2 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 , Fax: 630-377-6495 130 mA max. limited by control panel 130 mA max. limited by control panel 20 mA @ 12V, 23mA@ 24V 20 mA@ 12V, 23mA@ 24V Removal / replacement tool Retrofit adapter bracket. 6.6 in. (16.76cm) diameter C2006 Sv~tern SenSOI ~o..1lict~oon!,\l.qec,.toc:hangt-w'mO!J100flce \olsk~tem~comfnr CUl!e<'lt product ,nfotrNID"t rdudlog the Lit~ v.!f~ clthls~t• ~t AOS--Oll8,-00o5 · '//06· '1676 =•• DMP.COM O OE) 0 (;) 0 @DMPALARMS NEW PARTS 1100 Series™ Wireless Receivers ► Frequency-hopping 900 MHz spread-spectrum technology ► Seamless integration with DMP panels and other hardwired devices ► Simple programming ► Superior @nge ► Two-Way1" supervised wireless communication ► 3-, 60-or 240-minute supervision window, selectable by zone or output to maximize effectiveness ► Extended range with the 11000H and llOOXH ► Att@ctive and durable plastic housing for all units ► Internal antenna DMP Smart Devices Ensure Message Acknowledgement When it's Most Important FDNY SECURITY SIBIWJNG @ NEW PARTS < .·,~... . ,. --.-,:·, : ,. ,,~.' . •. . ¾ LISTED Providing double the system security Two-Way Supervised Wireless from DMP delivers unparalleled flexibility and simplicity without sacrificing power. • Built-in device testing • Simple programming • Superior range • Seamless integration with DMP panels and other hardwired devices Whether the installation is new construction. an upgrade or retrofit. Two-Way Wireless from DMP gets the job done faster with less effort. DMP LIFE SAFETY DEVICES 1100 SERIES WIRELESS SYSTEM FEATURES • Two-Way supervised communication • Built-in Survey LED visually confirms communications • Extended range and battery life • 3, 60 or 240-minute supervision window: selectable by zone or output to maximize effectiveness • Frequency-hopping 900MHz Spread-Spectrum technology • Attractive and durable plastic housing for all units 1 i 00 SERIES TRANSMITTERS • 1103 Universal Transmitter • 1161 /1162 Residential Smoke Detectors • 1165/1165H/1165HS Commercial Smoke Detectors • 1181 • 1182 • 1183-135F/1183-135R • 1184 Post Indicator Valve Outside Screw and Yoke Valve Supervisory Switch Heat Detectors Carbon Monoxide Detector _,,...~ .,.-,--~ CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM NEW PARTS LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: 7165-1157:0135 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) Digital Monitoring Products, lnc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Bade (417) 831-9362 Fax (417) 447-9698 Email: abade@dmp.com Page 1 of 2 Models XR150, XR350, and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders 711 S: Zone Expander (NOT for use with XR350) 716: Output Expander 717: Annunciator Module 860: Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 263H: Cellular Communicator (May be used as the standalone primary communicator) 263L TE, *263L TE-FN: Cellular Communicator (NOT for use with XR350) (May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RF Wireless Receiver 11 DOR: Wireless Repeater 1103: Wireless Transmitter *Revision 4-12-21 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO., M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 , . LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING· BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7272-1653:0152 Page 1 of 1 7272 --SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC System Sensor, Unincorporated Div of Honeywell lnt'I lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. 8.5-35 voe In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. Listee's name, model number, electrical rating and UL label. Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 fVmin. Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2019 DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing Expires June 30, 2020