HomeMy WebLinkAboutPS 2019-0071; 7 FOR ALL MANKIND; Sign Permits/Programs (PS)C_cicyof
Carlsbad
REVIEW FOR
SIGN PERMIT
P-11
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.gov
1)6V',;).ot~-0131..f
PLANNINGiiPLICATION # ps;?ol"I -OD!\
REC'D BY<, __ __,,__ ________ _
DATE 1/'1
SIGN FEE ... s .... G .... v ..... ·_t:?_0 _________ _
SIGN PROGRAM FEE ________ _
RECEIPT NO. _ SJ?_~\.\ _
NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602-
2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE*
All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign
elevations containing the following information:
1. North arrow and scale.
2. Location of existing buildings or structures, parking areas, and vehicular access points to the
property.
3. Location of all existing and proposed signs for the property.
4. Distance to the property line(s) for all proposed freestanding sign(s).
5. Provide an elevation for all proposed sign(s) which specifies the following:
A. Dimensions and area for all existing and proposed sign(s).
B. Materials the sign(s) will be constructed of.
C. Source of Illumination.
D. Proposed sign copy.
APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED
APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks
Name of Project:Tot: Q\,\ 7 PJ?tl<:: t no(·
Address of Project:ShZ.,,O pa..s cv c\-e,\ oo~k
Assessor Parcel Number: _______________________ _
Related Planning Case Number(S): ___________________ _
TYPE OF DEVELOPMENT:
(a) Residential (d) Hotel/Motel
~ Commercial (e) Service Station
(g) Theater
(h) Gov'UChurch/School
(c) Office/Industrial (f) Prof. Care (i) Public Park
SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA
U) Produce Stand
(k) Nursery
(I) P-U/OS Zone
Yes □ No □
Specific Plan Number ____ _
VILLAGE REVIEW AREA (If yes. please complete information on page 3) Yes D
SOUTH CARLSBAD COASTAL REVIEW AREA Yes □
SIGN ORDINANCE: Yes □ No □ COASTAL ZONE: Yes □ No □
P-11 Page 1 of 4
No □ No □
Rev. 02/28/18
EXISTING SIGNS:
TYPE NUMBER SIGN AREA SIGN HEIGHT
Pole
Monument
Wall
Suspended/Projecting
Directional
Canopy
Freestanding (Project Identity)
PERMITS ISSUED FOR EXISTING SIGNS: Yes □ No 0' Date ______ _
PROPOSED PERMANENT SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Pole**
Monument**
Wall 1 2--~·;.s-· h7 S-.Y-S''' I..( s I(
--
Suspended/Projecting I ' L .. -~ Z.lf 11 Z'-{'I
Directional
Canopy
Freestanding**
(Project Identity)
Digital Display
PROPOSED TEMPORARY SIGNS:
MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED
TYPE NUMBER PROPOSED SIGN SIGN AREA SIGN SIGN
ALLOWED AREA HEIGHT HEIGHT
Construction**
For Sale**
Banner
Interim
**Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed
for potential sight distance and visibility issues. Additional information must supplement
this application showing how the proposed signage will not encroach into the public right-of-
way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required
for such proposed signs.
P-11 Page 2 of 4 Rev. 02/28/18
SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN
APPLICATIONS
The following example illustrates the information that is required for all pole, monument, and
freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed
for potential issues by the Transportation Department, which will not allow signs to be approved
over the counter. Additional time will be required for on-site inspection.
I I I I
P/L • Sight Distance Requirement
• I . • I Show building ls . . : I . i I
: I , _____ , Show setbacks from all curbs ---
' . . I • I ' . . I . I Show all property lines I . .
P/L I i I
: . I • .
curb line . . • . . :
----------~---
• •
Sia}lt Visibility I
Street N ame(s) (i) I
I North
21.41.080 Sign design standards
Relationship to Streets: Signs shall be designed and located so as not to interfere with the
unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any
pedestrian, bicyclist or motor vehicle driver.
Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight
distance requirements at any public or private street intersection or driveway.
EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA
Total Building Square Footage: _________ sq. ft.
Total Building Street Frontage: linear ft.
Total Signage Allowance: sq. ft.
Existing Signage (sq. ft.): sq. ft.
Remaining Sign Allowance at Present: sq. ft.
Proposed Signage (sq. ft.): sq. ft.
Remaining Sign Allowance After Proposed Sign: sq. ft.
VILLAGE REVIEW AREA
Total Signable Area: _________ sq. ft.
Total Signable Area Length: sq. ft.
Total Signable Area Height: sq. ft.
Total Projection from Wall Face: inches
P-11 Page 3 of 4 Rev. 02/28/18
PROPERTY OWNER APPLICANT
NAME (PRINT OR TYPE) NAME (PRINT OR TYPE)
C;;71tv\OV1 0U~k..\-~ tfv11nam (;,vz,rYlL:A V)
MAILING ADDRESS MAILING ADDRESS
Sfo 1.-D )?CLS<:.O ci-e I h b ~ +<-fF/OV l 1 % l rs--~ t'Vl--0-VL CA-~ \I-<-.
CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE
c__co· t s \oa_&, Gfl crwo&-lhD a-txf-'?o'-l lf t-}-ttUJ,tho Y-Y\..(_ qt+ 'JD 2SO 37-o (o(,-o-z.,,
I CERTIFY THAT I AM THE LEGAL OWNER I CERTIFY THAT I AM THE REPRESENTATIVE
AND THAT ALL THE ABOVE INFORMATION OF THE LEGAL OWNER AND THAT ALL THE
IS TRUE AND CORRECT TO THE BEST OF ABOVE INFORMATION IS TRUE AND CORRECT
MY KNOWLEDGE. TO THE BEST OF MY KNOWLEDGE.
Ah,,/
SIGNATURE DATE /.BH//1// SIGNATURE ~ ,,/,.,,,.,,, DATE 07-01-IS
I' -.,
PLANNER CHECK LIST:
1. Field check by planner.
2. Within maximum length, area.
3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable.
4. Location: ❖ In right-of-way ❖ In visibility triangle at corner
5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues.
6. When approved route copy to Data Entry
APPROVED: Planner: ~ 7 Date: 7/~ /i 4 -~7-,-~--
P-11 Page 4 of 4 Rev. 02/28/18
Date:
To:
Company:
Email:
Tenant:
CC:
<X>
CARLSBAD
PREMIUM OUTLETS.
A SIMON CENTER
SIGN APPROVAL
July 1, 2019
Chuck Gladney
VFC
chuck gladney@vfc.com
7 for all mankind, Suite #109A
ecielak@takotyko.com
Carlsbad Premium Outlets
From: Judy Walton
Senior Tenant Sign Manager
Premium Outlets
jwalton@simon.com
¢<>
SIMON
PREMIUM OUTLETS
THIS NOTICE, TOGETHER WITH THE ATTACHED, MARKED-UP SIGN DRAWINGS, CONFIRMS LANDLORD'S
WRITTEN APPROVAL (AS NOTED) OF THE SIGN DRAWINGS AND ELEVATION FOR THE STOREFRONT & BLADE
SIGNS FOR "7 FOR ALL MANKIND", SUITE #109A, AT CARLSBAD PREMIUM OUTLETS.
Tenant is authorized to proceed with installation of its signs in accordance with the drawings, and as otherwise noted by
Landlord. Tenant or its contractor must field verify mounting height and special mounting conditions with onsite
management team of all signage included in this approval. Tenant's sign contractor must make an appointment with
Landlord's onsite management team (760) 804-9044 at least 48 hours before arriving to install the signs to confirm the
actual location of all signs on the building. The contractor will be required to sign all necessary forms and provide
required Certificate of Insurance and a copy of Tenant's sign permit at this meeting. Be prepared with plastic or tarps and
painter's tape to protect and cover all surfaces from dust and debris. NO duct tape or blowers allowed.
All signs shall be installed prior to Tenant opening at a place or places designated by Landlord. Tenant is responsible for
their sign installer to provide watertight installations from both the inside and exterior side of the wall penetrations and
proper cleanup of all surfaces upon completion. Tenant's installer must provide labeled photos of proper sealing from
inside and outside of sign install, making sure sleeves are shown where needed at eifs facades, to LL at time of install.
Tenant shall also be responsible for any and all costs associated with illuminating their sign(s). Keep in mind, work needed
may include an electrician if circuit is not near location .. Signs MUST be lit for opening.
Finally, Tenant and its contractor are hereby notified that any work, which involves cutting into or penetrating the existing
roof structure and/or roofing material must be performed by Landlord's Roofing Contractor at Tenant's Expense. Tenant
shall be liable for all damage resulting from unauthorized roof penetrations and their consequent effect on the integrity of
the roof and the warranties offered by the installer and manufacturer. Therefore, if it is determined that roof penetration
is likely required, Landlord must be notified in advance so that scheduling of its roof contractor may be available. If
penetrations/raceway not sealed properly by LL's roofer, then Landlord will correct on Tenant's behalf, and Tenant will
reimburse Landlord for the cost incurred.
Note: Landlord's approval herein means Tenant has met Landlord's sign requirements; it does not mean that Tenant
has complied with, and Tenant continues to bear full responsibility for compliance with, any regulatory, code and
permit requirements related to Tenant's signage.
5620 Paseo del Norte #A 109, Carlsbad, CA 92008
n;v;zoM-013L<
SIGN PERMIT NO. PS eJ-0/'1:.. t>b-"1. i : . ., • • i ~ •· • ·I I
I ,,
APPROVED BY DATE l-4· .. ' 1 _ I -z /-i ~-i PLANNING ,,,.-;,:· -
BUILDING ; ' I
5010 Venice Blvd. Los Angeles, CA 90019 Ph -323.937.4445 Fx -323.937.3912 Tako Tyko.com
Sign 1 -Halo-Lit Channel Letters
15' Frontage
Sq. Ft. -35.9' -Qty -2
aflJl. • 45"
17"
I
115"
C)1•11f!l@IP.i•i111#1·""14"'·41-L-----1 Corner f-9 -i@fff:iiH:H/·4
,-----------7
I I
I I
J,4•
Colors
Face & Returns -
BlaclhSem-Gloss
.. ..,, .
1' -&.· ,:r.,,-·
,r.,o-• e
0 Spacers -
Painted to Match Building
e
:r-eY.·
fJ
Sign 1 -Halo-lit Channel Letters
3/16" White Lexon Bocks
White Acrylic L-Clips ----
.080" Aluminum Returns --
.090" Aluminum Face
1.5" Spacer 2.5"
-Disconnect
Switch
-Transformer
Colors
Channel Letter Specs
Face: .090" Aluminum
Return. 080" Aluminum
Back: 3/16" White lexan Backs
Illumination
Type: LED
Power Supply: Behind the Wall
Input -120-220 VAY -0.26-.063 Amp
Output -2 .1 -3 .3 VDC -2 x 5 Amp Circuit
Mounting
Flex Connectors, Flex Conduit
4-5 of 1 / 4" x 3" Screws and Shields
Minimum 4 per Letter
® LISTED
Face & Returns -0 Spacers •
1 / 4• Acrylic Painted Painted to Match Building
Black Semi-Gloss Finish
■ P7rFoAjecMt Nome. Project Address. >o:ariRep Dasignat -~-=---~--,CAlp,,p:~, •1• ~r,a7£""~ Paoe.
5620 Paseo del Norte #A 109, Carlsbad, CA 92008 ., =::.:.~';;'.:'~ .. ~=-~ ...,-.......................... 111, .... . =-==::-~s:=-: I~
19-10348 ~-------~----------------------1...--------~---~----......J ""-Sa=l•'P='"=""-----___;;g.....;.(O.....;.PY.....;.RIG_HT_PRO.....;.TECT.....;.E.....;.O --'L---....i
Sign 2 -Non Lit -Blade Sign
i
I
Existing Bracket with
External Illumination
'----+---+--+1--Blade Sign
■
7
I
I
Sq. Ft. = 6' -Qty -1
24" 11 .9"
Side View
1/4" Acrylic FCO letters ----
29.7"
36"
/ To Hang from Existing Brocket
---Eye Hooks
.063" Aluminum Returns -----' LJ
Colors
Face & Returns -
1 /4" Acrylic Painted
Black Semi-Gloss Finish 0
l"
Cabinet and Bracket -
Painted White
Satin Finish
Site Pion ---~---------------~-----~-----------~~--~-----------------------------~------------------'
Site Pion Close Up
fJ
Allowable signage l .5 x 52 = 78 total square feet allowed
Proposed:
Signs:
45" x 115" = 5175 / 144 = 35.94 x 2 = 71 .88 square feet
Projecting sign :
24" x 36" = 864 / 144 = 6 square feet
Allowed
Proposed signage
78 square feet
77.88 square feet