Loading...
HomeMy WebLinkAboutPS 2019-0087; TRAIL'S END; Sign Permits/Programs (PS)Ccicyof Carlsbad REVIEW FOR SIGN PERMIT P-11 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.gov DEV 2 o tq .... o \ 'l,Q SEP O ~ 2019 ClTY OF CARLSBP,D PLJ.J-'.:'-i:~,JG DIVIS!ON ~~w~~GA~2,Dq-QQS?,7 SIGN FEE __ itt;;._,,._~.._,.__,.......,_ ______ _ SIGN PROGRAM FEE REC,EIPT NO. ';"""''3 .... 5,,......ttS ______ _ NOTE: AN APPOINTMENT IS REQUIRED FOR SUBMITTAL. PLEASE CONTACT THE APPOINTMENT SPECIALIST AT (760) 602- 2723 TO SCHEDULE AN APPOINTMENT. *SAME DAY APPOINTMENTS ARE NOT AVAILABLE* All plans submitted for sign permits/sign programs shall consist of a minimum of a site plan and sign elevations containing the following information: 1. North arrow and scale. 2. Location of existing buildings or structures, parking areas, and vehicular access points to the property. 3. Location of all existing and proposed signs for the property. 4. Distance to the property line(s) for all proposed freestanding sign(s). 5. Provide an elevation for all proposed sign(s) which specifies the following: A. Dimensions and area for all existing and proposed sign(s). B. Materials the sign(s) will be constructed of. C. Source of Illumination. D. Proposed sign copy. APPLICANT MUST SUBMIT THREE (3) SETS OF SIGN/SITE PLANS, A COMPLETED APPLICATION FORM, AND THE APPLICATION FEE. Average processing time: 2 weeks Name of Project: Trail' s End Address of Project: 3151 Donna Drive, Carlsbad, CA 92008 Assessor Parcel Number: 1 __ 5 __ 6 __ 09 ___ 1 __ 0"'"'1 o;..;;o __________________ _ Related Planning Case Number(S): __ c_T_0_4_-_1_4 _____________ _ TYPE OF DEVELOPMENT: (c) Office/Industrial (d) (e) (f) Hotel/Motel Service Station Prof. Care (g) Theater (h) Gov't/Church/School (i) Public Park SIGN PROGRAM AND/OR SPECIFIC PLAN CRITERIA (j) Produce Stand (k) Nursery (I) P-U/OS Zone Yes D No 181 Specific Plan Number ____ _ VILLAGE REVIEW AREA (If yes. please complete information on page 3) Yes D SOUTH CARLSBAD COASTAL REVIEW AREA Yes 0 SIGN ORDINANCE: Yes □ No O COASTAL ZONE: Yes O No 181 P-11 Page 1 of 4 No 181 No 181 Rev. 02/28/18 EXISTING SIGNS: TYPE NUMBER SIGN AREA SIGN HEIGHT Pole Monument Wall Suspended/Projecting Directional Canopy Freestanding (Project Identity) PERMITS ISSUED FOR EXISTING SIGNS: Yes O No O Date ______ _ PROPOSED PERMANENT SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Pole** Monument** 1 1 60 ft "2 2 9. 5 ft "2 6' 4 I 2 II Wall Suspended/Projecting Directional Canopy Freestanding** (Project Identity) Digital Display PROPOSED TEMPORARY SIGNS: MAXIMUM NUMBER MAXIMUM PROPOSED MAXIMUM PROPOSED TYPE NUMBER SIGN SIGN SIGN ALLOWED PROPOSED AREA SIGN AREA HEIGHT HEIGHT Construction** For Sale** Banner Interim **Prior to approval, all proposed pole, monument, and freestanding signs must be reviewed for potential sight distance and visibility issues. Additional information must supplement this application showing how the proposed signage will not encroach into the public right-of- way or present a traffic hazard. Page 3 of 4 illustrates an example for what would be required for such proposed signs. P-11 Page 2 of 4 Rev. 02/28/18 SITE PLAN REQUIREMENT FOR POLE, MONUMENT, AND FREESTANDING SIGN APPLICATIONS The following example illustrates the information that is required for all pole, monument, and freestanding sign permit applications. Prior to approval, all such proposed signs must be reviewed for potential issues by the Transportation Department, which will not allow signs to be approved over the counter. Additional time will be required for on-site inspection. I I l I P/L 1 Siaht Distaiice Requirement Show building ls I I . i I I . I l Show setbacks from all curbs '---I --- I • I ' . I • • I Show all property lines I . P/L : i I :,.t I curb line l l l ----------~--- • • Sipt Visibility I Street Name(s) (i) I I North 21.41.080 Sign design standards Relationship to Streets: Signs shall be designed and located so as not to interfere with the unobstructed clear view of the public right-of-way and nearby traffic regulatory signs of any pedestrian, bicyclist or motor vehicle driver. Sight Distance: No sign or sign structure shall be placed or constructed so that it impairs the sight distance requirements at any public or private street intersection or driveway. EXISTING SIGN PROGRAMS OR SPECIFIC PLAN SIGN CRITERIA Total Building Square Footage: sq. ft. -------- Tot a I Building Street Frontage: linear ft. Total Signage Allowance: sq. ft. Existing Signage (sq. ft.): sq. ft. Remaining Sign Allowance at Present: sq. ft. Proposed Signage (sq. ft.): sq. ft. Remaining Sign Allowance After Proposed Sign: sq. ft. VILLAGE REVIEW AREA Total Signable Area: sq. ft. -------- Tot a I Signable Area Length: sq. ft. Total Signable Area Height: sq. ft. Total Projection from Wall Face: inches P-11 Page 3 of 4 Rev. 02/28/18 PROPERTY OWNER APPLICANT NAME (PRINT OR TYPE) NAME (PRINT OR TYPE) Donna Drive Reality, LLC Elliot Kadota MAILING ADDRESS MAILING ADDRESS 5505 Cancha De Golf 5505 Cancha De Golf CITY STATE ZIP TELEPHONE CITY STATE ZIP TELEPHONE Rancho Santa Fe CA 92091 858-755-0216 Rancho Santa Fe CA 92 0 91 858-77 9-933 9 I CERTIFY THAT I AM THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. I SIGNATURE DATE PLANNER CHECK LIST: 1. Field check by planner. 2. Within maximum length, area. I CERTIFY THAT I AM THE REPRESENTATIVE OF THE LEGAL OWNER AND THAT ALL THE ABOVE INFORMATION IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. / . ,· /,,.,.... ½.,:;..,, ~,,,· .-~ /~-1/ c/~ SIGNATURE DATE 3. Style consistent with Sign Program and/or Specific Plan criteria, if applicable. 4. Location: ❖ In right-of-way ❖ In visibility triangle at corner 5. Pole and monument signs to be checked by Transportation Engineering, for visibility issues. 6. When approved route copy to Data Entry APPROVED: Planner: ~y Date: '3/2JJ/l9 P-11 Page 4 of 4 Rev. 02/28/18 G :: ..,-..... • ct) 0 I N <1 MONUMENT SIGN 1 '-0" 1" to • T"" -co T"" ~ .. , -. -.... ··--.•;,a,;•·-;~~.::·· ... -: .... •, . •'.~ .... -.~-··· <1 ••• .. ,4 .A. 4 4 .cl q. <f,& d• .4.· <I. ,; ·. ,d 4 <1 .. . 4 e. <I .s ,d 4 ·<1 . <1 .,4 k ll 4 "14 -d' ,<i ~ 4· -· -<: 6'-1" 4'-2" .;:. • -~ ••••• , •❖ ... . . .. .. ·:--;,_~ ...... -.. . ,. . .. . . . .. <1 4 4 -~ .4 . " .; . 4 ../i "'· ,1 , <1. 4 <I <I 4 -4 .. <1 ~ ·. <t •• <I .<! 8'-1 "'' <1 4 <I 4 ,i ·<1 4 • <f ·4 " <I: 4 <1 " 4 </. <1 4 4 A <1 <1 ,.. .A A "' ILS END DEVELOPMENT MONUMENT 3 2 4 . . <1 ¥4 ~ <I ,!,. . A 4 <1 4 ,,; .,, <! 4: .. "" ,& <1-4 .., .. .,, " .. 4 .d. <l 4 q 4 .,. • <l ••• 11 ·. <f " 4 <t 4 <I 2, • .a 4 j/ SIGNAGE PLAN SCALE: N.T.S. (SEE PLAN FOR LOCATION) LEGEND: 11 111 CHAMFER 1" 6 7 10 4 •• ,£ <1 A <I : N .., . .:l· <:_. " /4 1 .., 4 ., 4 9 ~ a " .:::1 "" G <$ • " . .. 8 DEVELOPERS NAME: ____________ _ ADDRESS: TELEPHONE: DATE PLAN PREPARED: _________ _ BY: DATE INITIAL DESIGNER OF WOR< REVISION DESCRIPTION ® FINE TEXTUR.ED, 1 SIDE LETTERED, STUCCO MONUMNET SIGN STUCCO SCREED STUCCO co_oR #1: COLOR COAT TO MATCH ARCHITECTURE NOT USED 8X8X16 CMU GROUT CELLS SOLID 6X8X16 CMU GROUT CELLS SOLID 3/8" TAPPED, DRILLED, BRASS LETTERING W/ PATINA FINISH GLUE 1" CLEAR OF STUCCO (E600 GLUE). FONTS: NE\V TIMES ROMAN -6" LETTERS; POUR IN PLACE CONCRETE FOOTING W/ #4 BARS @ 12" O.C . 90% COMPACTED SUBGRADE 4"X12" CON:RETE APRON FELT EXPANSION JOINT #4 BARS ITTV2.D\q--O (:kO SIGN PERMIT N 'i5S2.Dlt\·w_2 APPROVED BY /C,j v~ PLANNING / -· BUILDING DATE "i-2.Lrl~ ~· L!_J CITY OF CARLSBAD I SH~ETS I DATE INITIAL DATE INITIAL OTHER APPROVAL CITY APPROVAL PLANNING DIVISION PLANS FOR: TRAILS END DEVELOPMENT CT 04-14/ ZC 04-10/ HOP 04-07/ PUD 04-12/ SCE 04-14(A)/ CD 08-07 TITLE SHEET I APPROVED: .PLANNING DWN BY: CHKD BY: __ ~_ . .,,,_., RVWD BY: PROJECT NO. CT 04-14 DRAWING NO. / ' ( , ! / I i \ \ \ \ \ \ \ ' -1.J) \ 0 , I I I I I I ' \ \ ) I i i I ' j l / I i f j I NORTH SCALE: 1" = 20 FT. REFERENCE NOTES SEE DETAIL/ SHEET NO. 6" CONCRETE MOW CURB RECREATION AREA PLAY STRUCTURE PLAY STRUCTURE USE AREA TOT LOT PLAY STRUCTURE SIGNAGE PLAY SURFACE CONCRETE WALK OR PAD (SCORED AT 5' O.C.) ttD\ \D7 (D ® ® © ® ® 0 ® ® @) WALKWAY ARBOR------------------@ ENHANCED CONCRETE PAVING (SCORED AT 5' O.C.) @ @ @ @ @) @ @ PROJECTMONUMENT_.•·_s1_G_N_A_G_E_· ___________ @-,-,,. -® 1 B 4 TRASH STRUCTURE 8 ft. ADA ACCESSIBLE PICNIC TABLE----------~ 6 F. PICNIC TABLE ________________ \El_._14 © @ ----------@ 6 FT. BENCH------------------ 5 FT. TALL TUBULAR STEEL VIEW FENCE MAIL CENTER (1 CABINET), W/ 8" THICK CONCRETE PAD --- ORCO AQUA-BRIC PERMEABLE INTERLOCKING PAVERS (SEE DETAILS, ENGINEERS SITE PLAN SHT. 3) @ GRASSCRETE (SEE ENGINEER'S PLAN) @) BIO-RETENTION BASIN @) EMERGENCY SPILLWAY @ RETAINING WALL (SEE ENGINEER'S PLAN) @ 6 FT. HIGH S.M.U. SOUND WALL @ LOT 17 PASSIVE RECREATION AREA (SEE ENGINEERS PLAN) @ ' I RECREATION AREA DETAIL SCALE: 1" = 20' -O" / ,' ,.l ; / / , , l_ 11 ·.-~?'..:..-,~:J~ 3/7:9 ~i9~--r: .,(. "! , •, .J k:_..·•1·--,12 -,,._ .. I I f ,f y I , ~ \ .---"-·t\ \, , ' ~ \ ,_.,--·· \ \ ,. \ / \' ~ ~ \ I . \ . ' PS PROJ. NO. 131116 JUNE4, 2015 I SH~ET I CITY OF CARLSBAD PLANNING DIVISION I SH~rs I PLANS FOR: TRAILS END DEVELOPMENT CT04-14/ ZC 04-10/ HOP 04-07/PUD 04-12/ SCE04•14(A)I CD 08-07 DEVELOPERS NAME: ____________ _ TITLE SHEET Expiration Date: _1_2_-_3_1_-_1_6_ ADDRESS: DATE PLAN PREPARED• _________ _ BY: PLANNING I _________ T:,:E::L::EP::_:H:O:'.'.N:'.'.E::.• .:::::::::=======-f-=ac-k=+----------------+-;;-;:,;;c--h=;;;-t-;=,--\,;;;=-i ~~~~===,;==~~~:2=:~==,;::;:~~~;;:: ~ rDWN BY, --,,;,-PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: --""'~· ·~ CT 04-14 DESIGNffi OF WOR( REVISION DESCRIPTION OTHER APPROVAL Cl1Y APPROVAL RVWD BY: I APPROVED: TRAILS END CARLSBAD, CA ELECTRICAL CONSTRUCTION NOTES I. THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THE SPECIFICATION. 2. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO FERFORJM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. A. ALL MATERIALS AND EQUIPMENT SHALL BE COMMERCIAL AND SHALL CARRY A U.L. LABEL. B. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEAR ON T,-1E UNDERWRITER'S LABORATORIES LIST OF APPROVtD ITEMS AND SHALL MEET REQUIREMENTS OF ASTM, IEEE, 2017 NEC, NEMA, AND OTHER RECOGNIZED STANDARDS AND SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRIC CODE AND OTHER APPLICABLE CODES, WHICHEVER ARE MORE STRINGENT. 3. THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 4. ALL WORK TO BE IN ACCORDANCE WITH THE 2017 CEC (20 17 NEC) AND ALL Al0 PLICABLE FEDERAL, STATE AND LOCAL CODES. 5. SECURE AND PAY FOR ALL REQUIRED PERMITS AND INSPECTION CERTIFICATES. G. ABOVE GRADE CONDUIT SHALL BE STANDARD RIGID STEEL ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS. EXCEPT AS OTHERWISE APPROVE[J BY ARCHITECT. RIGID CONNECTIONS SHALL BE COMPRESSION TYPE. UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 OR 80 PVC BURIED A MINIMUM Of 24". 7. WIRE SHALL BE SINGLE CONDUCTOR COFFER WITH GOO VOLT INSULATION. ALUMINUM CONDUCTORS ARE NOT PERMITTED. # I 2 AND SMALLER SHALL BE SOLID. #IO AND LARGER SHALL BE STRANDED. MINIMUM WIRE SIZE SHALL BE# I 2. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. ALL WIRING OF ANY TYPE SHALL BE IN CONDUIT. A. GENERAL WIRING SHALL BE THWN OR THHN. 8. ABOVE GRADE WIRE CONNECTORS SHALL BE BY "SCOTCHLOO::' OR EQUAL FOP' #8 OR SMALLER AND HB "LOCK-TITE" FOR #f; AND LARGER. 9. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING OR CHANNELING AND FAl"CHING REQUIRED FOR ANY WORK UNDER THIS DIVISION. ANY CUTTING SHALL HAVE PRIOR APPROVAL OF H1E OWNER. i 0. PROVIDE SAFETY AND DISCONNECT SWITCHES, SHALL BE FUSED OR NON-FUSED AS CALLED FOR ON DRAWINGS AND AS REQUIRED BY CODE. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEFOWER RATED AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC OR EQUAL. I I. JUNCTION, PULL BOXES AND COVERS WITHIN BUILDING SHALL BE GALVANIZED STEEL, CODE GAUGE SIZE AND ACCESSIBLE. I 2. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES, AND UPON COMPLETION SHALL TURN 0\/ER TO THE OWNER A "RECORD" SET OF PRINTS SHOWING THE CHANGES. 13. ALL ELECTRIC WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING MAINTAINING AND REPAIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC, NECESSARY FOR THE INSTALLATION OF WORK AND SclALL BE FASTENED TO STEEL, CONCRETE OR MASONRY, BJT NOT TO FIFING. ALL CONDUIT SHALL BE CONCicALED WHERE POSSIBLE. EXFOSED CONDUITS SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEASED 3" FROM WATER UfiES WHEl~EVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. CONDUCTORS SHALL BE ON CONDUIT. DUCTS, OR APFROVED RACEWAYS. 14. ALL 90 DEGREE ELBOWS TO BE FACTORY MADE BENDS. I 5. PRIVATE LIGHTING SYSTEM SHALL NOT BE JOINT TRENCH WITH FUBL!C UTILITY SYSTEM. I G. CONTRACTOR TO MAINTAIN PROFER SEFARATION AS REQUIRED BY THE UTILITY COMPANIES. I 7. CONTRACTOR SHALL BE RESFONSIBLE FOR CALLING FOR ANY AND ALL UTILITY AND CITY INSPECTIONS. I 8. ALL GROUND CONDUCTORS SHALL BE SPLICED TOGETHER WITH APPROVED CONNECTOR AT FULL BOXES AND CONNECTED TO GROUND LUG INSIDE POLE. 19. SEE IMPROVEMENT FLANS FOR SITE, SEWER AND WATER (ETC.) IMFROVEMENTS PRIOR TO START OF CONSTRUCTION. 20. CONTRACTOR SHALL CONTACT "DiG ALERT" FOR MARK-OUT PRIOR TO TRENCHlfiG AS REQUIRED. 21. THESE PLANS ARE SCHEMATIC AND ARE FOR THE PURPOSE OF SHOWING HOW TO CONNECT THE ELECTRICAL SYSTEM. WHILE THE DRAWING IS AT ACTUAL SCALE, THE SYMBOLS REFERENCED ARE NOT, AND MAY AFFEAR TO SHOW THE EQUIPMENT IN PLACES NOT INTENDED. THE CONTRACTOR IS TO FIELD VERIFY ALL UTiLITY COMPANY SERVICE POINTS/METER LOCATIONS, POLES, PULL BOXES BUILDING LIGHT LOCATIONS, SERVICE EQUIPMENT LOCATIONS AND OTHER ELECTRICAL APPURTENANCES PRIOR TO START OF CONSTRUCTION. ANY DiSCREPANCIES ARE TO BE ADDRESSED TO THE CLIENT BY MEANS OF A "REQUEST FOR INFORMATION" (RFI). CONTRACTOR IS TO VERIFY ALL LIGHT LOCATIONS WITH THE CITY PRIOR TO START OF CONSTRUCTION AND DURING STAKING. REFER TO L!GHT STANDARD DETAIL FOR STANDARDS. CONTRACTOR SHALL CONTACT "DIG ALERT" FOR MARK,OUT PRIOR TO TRENCHING AS REQUIRED. 22. PANEL CIRCUIT DIRECTORY TO COMPLY WITH SECTION 408.4, CEC. 23. NATIVE SOIL SHALL BE ACCEPTABLE FOR TRENCH BACK FILL PROVIDED THAT THI: FILL MATERIAL USED SHALL PASS THROUGH A I" SIEVE (CITY STANDARDS). SEE NOTES; DETAIL E/EL-3. 24. CONTRACTOR SHALL LABEL EACH CIRCUIT WITH PHENOLIC PLASTIC LABEL TAGS IN ANY DEVICE THAT HAS ACCESS. THIS SHALL INCLUDE LIGHT POLES, PULL BOXES, PANELS, AND ETCETERA. PANEL, CIRCUIT NUMBER AND VOLTAGE SHALL BE IDENTIFIED. TAGS SHALL BE AFFIXED WITH NYLON ZIP-TIES. SPECIFICATIONS I. ALL PULL BOXES TO BE TYPE 3-1 /2 PB ( I 0-I /2" X I 7-I /2" X I 2"DJ WiTH CONCRETE BOLT DOWN COVER MARKED "ELECTRICAL", BOX-C9EB, LID-C9ROG). LEAVE 3' SLACK OF CONDUCTORS IN PULLBOX. SIZE FER SECTION 370-28, CEC. 2. FUSE HOLDERS TO BE WATERPROOF AND UL LISTED. 3. ALL CONDUIT BELOW GRADE AND OUTSIDE OF PARKING LOT OR ROADWAY TO BE MINIMUM 3/4" SCHEDULE 40 PVC. 4. ALL CONDUIT UNDER ROADWAY OR PARKING LOT TO BE MINIMUM I" SCHEDULE 40 PVC. 5. ALL CONDUIT EXPOSED ABOVE GRADE AND INTERIOR TO BUILDINGS TO BE MINIMUM !/2" EMT. G. ALL SPLICES BELOW GRADE SHALL BE MADE IN APPROVED PULL BOXES AND SHALL BE WATERTIGHT. USE ONLY EPOXY ENCAPSULATED TYPE 3M BAGS OR EQUAL. 7. ALL BELOW GRADE CONDUIT SHALL BE SEALED UPON COMPLETION OF INSTALLATION. 8. ALL ELECTRICIANS TO HAVE FROOF OF CALIFORNIA ELECTRiCIANS CERTiFICATE/CREDENTiALS. 9. ALL ABOVE GRADE JUNCTION BOXES TO BE WEATHER-PROOF. SIZE FER SECTIOII 370-28, CEC. I 0. IN-LINE LOW VOLTAGE TRANSFORMER SHALL BE 'ALLIANCE OUTDOOR LIGHTING', MODEL #ETFGO GENERAL NOTES I. THE CONTRACTOR SHALL FREFARE A CONDUIT LAYOUT DRAWING INDICATING THE LOCATION OF ALL EXISTiNG UNDERGROUND UTILITIES AND THE ROUTING AND DEPTH OF ALL NEW UNDERGROUND FEEDER AND BRANCH CIRCUIT CONDUITS. THIS DRAWING SHALL ALSO INDICATE THE UNDERGROUND PLUMBING, FIFING AND ALL OTHER Ui,;DERGROUND STRUCTURES NEW AND EXISTING. THE DRAWING SHALL BE USED AS THE BASIS FOR COORDINATION BETvVEEN THE DISCIPLINES. THE CONDUIT LAYOUT DRAWING SHALL BE SUBMITTED TO THE DISTRICT AND ARCHITECT FOR REVIEW AND APPROVAL PRIOR TO CONDUIT INSTALLATION. NO TRENCHING SHALL BE STARTED OR CONDUIT SHALL BE INSTALLED UNT!L THIS CONDUIT LAYOUT DRAWING HAS BEEN SUBMITTED, REVIEWED AND APPROVED. LUMINAIRE SCHEDULE SPECIFIED BY: VISUAL CONCEPTS LIGHTING (858-275-4503) TYPE SYMBOL FIXTURE VOLTS LAMPS MOUNTING lf) _J z z o,/ u lf) <( DESCRIPTION MFR$ LU [L > ::J ::J 1--_J lL u _J llJ CATALOG NO. ~ 2 u _J g 0 0 lf) lf) 0 co 0 r,,. 1--_J o,/ llJ _J _J cO LU I [L (\j (\j 0 st-r,,. 0 ~ LU ::J [L ~ 0 ::J z llJ 0... 5' 0 _J u ,L lL -_J _J 2 I --(\j (\j (\j z TYPE lf) lf) [L @ Ul 0 X X X STREET LIGHT CREE LIGHTING, o-CJ lf) 0 20 50 (DETAIL AIEL-3) ARE-EDG-2MB-DA-02,E-UL-BK-700'40K 3 -0 I LED POLE, AV POLES /IND LIGHTING Cf) st-SSS 204-I I , I -BLACK @ 0 0 X X PEDESTRIAN LIGHT CREE LIGHTING o-1%] lf) 0 40 37 (DETAIL B/EL-3) ARE-EDG-4MB,DA,02,E-UL-BK-525-40K-ML 4 lf) 0 I LED POLE, AV FOLES t,ND LIGHTING Cf) st- SSS i 24, I i -I -BLACK © Ul 0 X X BOLLARD LIGHT CREE LIGHTING 0 Ul 0 MULTI 22 (DETAIL C/EL-3) PWY-EDG-5M-F4-02-E-UL-BK-350-40K 15 Ul 0 I LED -st- . CREE l!GHTING @ lf) 0 X > X MONUMENT I I -0 7 19 SIGN LIGHT FLD-OL,SN-b2°07 -D'UL-BK-5 25 K-40K I -0 I LED ([)ETAIL D/EL-6) -T ® 0 X X X TRELL!S LIGHT ALLIANCE OUTDOOR LIGHTING ■ 0 0 MULTI 5 (DETAIL G/EL-3) DL-I OO-LED-5W-F 2 lf) r,,. I LED Cf) (\j LED DRIVER REQUIRED AS SHOWN IN DETAIL. (QTY I J MODEL #ETFGO DISTRIBUTOR TO CONTACT TIM WESTON OF WESTERN LIGHT SALES FOR QUOTES ON CREE AND AV POLES AND LIGHTING PRODUCTS. (858) 7G2,2 I I 2 SHEET INDEX SHEET# DESCR!PT!ON EL-I LEGEND, NOTES, SPECIFICATIONS, LUM!NAIRE SCHEDULE EL-2 LIGHTING PLAN EL-3 DETAILS, PANEL SCHEDULE EL-4 T!TLE-24 EL-5 PHOTOMETRIC PLAN LEGEND BELOW GRADE cLECTRICAL CONDUIT AND WIRE RUN. SEE PLANS FOR TYPE AND# OF WIRES. IZI I OOA, I 20/240V, 10, 3W METER PEDESTAL. VERIFY EXACT LOCATION. SEE DETAIL D/EL-3. l;;jjjjjl 5DG$E ELECTRICAL SERVICE POINT. VERIFY EXACT LOCATION WITH UTILITY COMPANY WORK ORDER. m CONCRETE UNDERGROUND PL!LLBOX. SEE SPEC. I AND DETAIL F/EL,3. o-CJ TYPE 'A' STREET LIGHT. SEE DETAIL NEL-3 o-1%1 TYPE 'B' PEDESTRIAN LIGHT. SEE DETAIL B/EL-3. (31 TYPE 'C' BOLLARD LIGHT. SEE DETAIL C/EL-3. 111-1-41 TYPE TY MONUMENT LIGHT. SEE DETAIL H/EL-3. ■ TYPE 'E' TRELLIS LIGHT. SEE DETAIL G/EL-3. A-1 CIRCUIT DESIGNATION. 1 ST# INDICATES PANEL. REMAINING #'5 INDICATE CIRCUIT POSITIONS. ffi IRRIGATION CONTROLLER (D ABOVE GRADE WEATHER,PROOF JUNCTION BOX. SEE DETAIL I/EL-3. TITLE-24 (20 I G) APPLICATION CATEGORIES 0 TRAILS END DONNA DRIVE AND CARLSBAD VILLAGE DR. CARLSBAD, CA SEE SHEET EL-4 FOR MA,DATORY MEASURES. LIGHTING POWER ALLOWANCE FOR GENERAL HARDSCAPE-ALL DRIVEWAYS, PARKING STALLS AND PLANTING ISLANDS, SIDEWALKS. STAIRS 2G,359 S.F. OF ILLUMINATED HARDSCAFE. TOTAL GENERAL HARDSCAPE LIGHTING ALLOWANCE=4,983 WATTS. TOTAL INSTALLED WATTS= G28 PER OLTG-I C FART40F4 .. ,µ \j (\) o' "-IL ..111 .. ,µ C (\) u ..111 :'"(' \. ·":·' .. D z lU (,f) _J <( Di \---- (,f) lU <( u 0 D <( oJ (,fl _J Di <( u lU \----> <( <( Uz Oo (,f) \---- (,f) G <( z D :r: z (,fl <( <( z 5 0 . lU (,f) (,fl 0 <( 0 ~ (\j II... Revrsrons: L() (\j 0 (\j Cf) <( u 0 0 D D z 0 u (,f) lU II... Sheet Info: Drawn By, P JD Checked By, KPSR Scale: N/A Date, 03/0 I/ I 7 Job No., MAI I4/03I2I-CO I lit... Sheet Title: NOTES SPECIFICATIONS llt... Sheet Reference: EL-I Sheet, 3 of 7 8 i ! I I I i I I I I I ' ' ' i I I I I I I I ! i I ! I i I I I ! i I I I ' I I / / I , 8 I / I I I I / I / I I / / I I / / / / / \ \ \ / / / / I I / / I I I / I / / / I / / / I I I / I ' I I I ' \ \ \ \ \ I \ \ \ \ \ \ \ I \ \ ' \ I I \ I \ \ \ \ \ ' I \ \ \ I ' \ \ / / / / I / I / / / / / / / / / / / / / / / \ I I \ \ \ \ \ \ ' ' \ \ \ \ / / / / I I / \ I \ \ I / / \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ ) / / / I / / I I / / / I / I / / I I I / I / / / / I / / I / I / / / / / / / / I I / / / / / / ,· / / / / , '· \ \ \ I '· \ \ I / / / / I I I PLAN NOTES 0 0 0 G) ® © 0 0 PROVIDE I OOA, 120/240V, 10, 3W METER PEDESTAL 'A'. BEE DETAIL D/EL-3. PROVIDE 3" CONDUIT PER UTILITY WORK ORDER. VERIFY CONDUIT ROUTING, TRENCH AND BACKFILL INSTRUCTIONS WITH UTILITY WORK ORDER. SDGtE UTILITY COMPANY SERVICE POINT. VERIFY EXACT LOCATION WITH UTILITY WORK ORDER. UNDERGROUND CONCRETE PULLBOX. SEE SPEC I/EL-I. AND DETAIL F/EL-3 FOR INSTALLATION DETAIL. PROVIDE I" C-2# I 0, I# IO GND. BURY 24" BELOW GRADE. PROVIDE I" C-4# I 0, i #IO GND. BURY 24" BELOW GRADE. PROVIDE I" C-4#8, I# IO GND. BURY 24" BELOW GRADE. CONTRACTOR TO INSTALL CREE LIGHTING #XA-20BLS-4 NORTH SCALE: I "=20'-0" Under ground Service Alert ofllol.rtlwmc..lll'or-nll>. CALL TOLL FREE 1-800-277-2600 T'w'□ 'w'DRKJNG DAYS BEFORE YOU DIG . ..,,;, -,._-~\· . ··,. __ -, .. ,, <( u 0 ~ 0 z <( _µ 11.J \.) co ()) (J) (J) o' __J __J '-IL ...i _µ C ()) u ...i <( DL DL <( I-u (J) 11.J 11.J ~~ Uz Oo (J) 1-- (J) 0 <( z Dr z (J) ~~ ~ 11.J (J) 0 <( 0 2 (\j Iii.. Rev1s1ons: LO (\j 0 (\j Cf) <( u 0 0 0 z 0 u (J) 11.J Iii.. Sheet Info: Drawn By: P JD Checked By, KPSR Scale: 1 "=20' Date, 03/0 I/ I 7 Job No., MAI 14/03121-COI Iii.. Sheet Title: LIGHTING PLAN Iii.. Sheet Reference: EL-2 Sheet, 4 of 7 ---- :;,; 2 ij C\J . FOUNDATION TO BE 2" ABOVE GRADE INSTALL BACK Of SIDEWALK SIDEWALK ANCHOR BOLTS (4) 3/4" Rx 30" L x 3" H WITH APPROVED GND. CONNECTOR 12" REBAR,(4) #4 VERT. W/ 7 x #3 HORIZONTAL I 2" OC WITH 3#3 WITHIN TOP I 2". MIN. 3" CONCRETE COVER. SGO-C-2500 P.C.C.AGAINST UNDISTURBED OR COMPACTED (95% MIN.) EARTH. bO" 24" TYPE 'A' STREET LIGHT INSTALLATION DETAIL BREAKERS SHALL BE SERIES RATED AND MARKED ACCORDING TO NEC. "STRONG BOX" QU!CKPAD MODEL #QP-MPE TO EXISTING POWER SOURCE FILL SUBSTRUCTURE TO 2" BELOW GRADE LEVEL WITH I " SMOOTH GRAVEL AFTER CONDUIT INSTALLATION. 2" UNDER- GROUND PULL SECTION M FULL CUT-OFF LED FIXTURE. SEE SCHEDULE. ROUND STEEL POLE. SEE FIXTURE SCHEDULE HANDHOLE TO FACE HARDSCAPE GROUND LUG ROUND BASE COVER PROVIDE NON-SHRINK GROUT UNDER BASE PLATE PROVIDE PULLBOX WITHIN 5' OF STREET LIGHT. SEE DETAIL F/EL-3. CONDUIT AND WIRES, SEE PLANS I "C-2# I 0, 1#10 GND. 20' #4 BARE COPPER WIRE COILED IN BASE. TEST BLOCKS PHOTOCELL WITH EXTERNAL EYEBROW BREAKERS SHALL BE SERIES RATED AND MARKED ACCORDING TO NEC ASTRONOMICAL TIME-CLOCK WITH BACK-UP RESERVE IN PED. 'A' ONLY. 4"1--+---SEE PLANS FOR WIRE AND CONDUITS. PROVIDE 5/8" x 8' COPPER CLAD GROUND ROD WITH #4 COPPER GROUND WIRE AND AND APPROVED CONNECTOR. METER PEDESTAL 'A', LIGHTING CONTROLS, I -LINE AND INSTALLATION DETAIL NOTE, CONTRACTOR TO PERFORM NOTE-TIME LIGHT ADJUSTMENT AFTER INSTALLATION. CMN STRUCTURAL ENGINEERS Project Name: IIJ!l'isson ·a-nd Assoc. -Trall_'.Erid·co1.-. 20-ft. pOle· Page No. By: CN Wind Load F=qhG4 DOrina ~:-and-Carisb:id Village, Carlsbad, CA · Seismic load {ASCE 7-10 Eqn. 29.4-1) Exposure C V = -ibO mph Risk Category= 1 K,= 0.9 at 20 ft Ka= 1 % = .00256 * K, K.:t Ko V'"= qh= .6*qhu~"' 23.0 psf (Ult) 13.8 psf (ASD} G= :, 0:85 yo ·_2-Fig. 29.5-1 Dp01,= 0.58 ft h" 2ff ft. D*q".5 = Z.80 h/D = 34.3 Area ht. A .. ht Fixture= 1.5 20 Pole= 11.8 10 Total= 13.3 Force at: 11.13 ft F"' q1,G Cr A F001e= 13.8x 0.85 2 13.3 312.56 lb. @ 11.13 ft Depth of embedment required for Nonconstrained CBC 2013 Section 1807A.3.2.1 cannot use this formula where d;,,12' 0.SA(l +( 1 +( 4.35h/ A})" .5) po 312.56 lb ho 11.128 ft be .'2-ft d• 4.S-ft PP"' 200 pcf/ft 51 = 300 psf Ao 1.219 be dreq"' 4.50 ft d = 24" -5.4 " 30 118 148 Fp = .4*ap*Sds*W* R/1 a?= 2.5 So,= Rp = 3 '" We 450 lb. z/h = Fp= 0.27 W olt 0.189 W ASD 85.05 lb ASD Wind Force Govern Use 24 "dia. x 54 Deep pier with 4 # 5 vertical bars with 3 # 3 ties within top 8"@ 2" o.c and #3@ 12" o.c remaining. MOUNTING: PEDESTAL PANEL 1 Date: 2/20/2017 (1 + z/h) OJll 1 0 < 312.6 lb. A -- 2 in C\J FOUNDATION TO BE 2" ABOVE GRADE. SIDEWALK ANCHOR BOLTS (4) 3/4" Rx 30" L x 3" H WITH APPROVED GND. CONNECTOR 48" REBAR,(4) #4 VERT. W/ 7 x #3 12"~ HORIZONTAL I 2" OC W!TH 3#3 18" WITHIN TOP I 2". M!N. 3" CONCRETE COVER. SGO-C-2500 P.C.C.AGAINST UNDISTURBED OR COMPACTED (95% M!N.) EARTH. TYPE 'B' PEDESTRIAN LIGHT INSTALLATION DETAIL LOCATION: NW CORNER VOLTAGE: I 20/240 PHASE: i WIRE: 3 AIC SYM: i0,000 BUS: I 25A MAIN: IOON2P (A) (A) WATTAGE L M p B C C B p M LOCATION T I 0 K I p I K 0 I 0A 0B G s L R R H R R L s STREET/PED LITES 328 12 I 20 I A 2 20 I STREET/PED LITES 300 12 I 20 3 B 4 SPACE 5 A G SPACE 7 B 8 SPACE 3 A 10 SPACE I I B 12 20 SPACE 328 300 WATTS/LINE TOTAL WATTS: I 128 TOTAL 0A: G48 WATTS PANEL AMPS: 4.7 TOTAL 0B: 480 WATTS HIGH PHASE LCL AMPS, G.75 (A) LIGHTS CONTROLLED BY PHOTOCELL AND LIGHTING CONTACTOR. PHOTO CELL MOUNTED ON SIDE OF CABINET. PROVIDE 'EYE-BROW OVER PHOTOCELL. A-12 { 'ON' i -~s,:;j,--=l,!.j.h~fs~ -7 I I I H C I I I N <i: ~ I L _______ c.:__~ __ J NOTE, L WATTAGE T LOCATION G 0A 05 320 IRRIG. CONTROL SPACE SPACE SPACE SPACE 180 CONT ACTORS 320 180 BREAKERS SHALL BE SERIES RATED AND MARKED ACCORDING TO NEC. CONTRACTOR TO PERFORM NOTE-TIME LIGHT ADJUSTMENT AFTER INSTALLATION. i--1-------5' ------;-i l/2"EMT-2/C#IG_L------ill LV CABLE. KUN TYPE 'E' TRELLIS LIGHT INSTALLATION DETAIL ~--· -------------- EXPOSED ON 5ACK5!DE SIDE OF TRELLIS. PA! NT TO MATCH 7 l-, RECESSED W'EATr-'.ER PROOF JUNCTION BOX. PROVIDE GOW. I 20-I 2V ELECTRONIC STEP-DOWN TRANSFORMER IN J-BOX. SEE SPEC. I 0 CONDUIT AND WIRES, SEE PIANS H 4' SIGNAGE DIMENSIONS" S'W x 4' H. TOTAL SQUARE FOOTAGE-20 SF. 30" FRONT VIEW CONDUIT AND WIRES, SEE PLANS TYPE 'D' MONUMENT LIGHT INSTALLATION DETAIL FULL CUT-OFF LED FIXTURE. SEE SCHEDULE. ROUND STEEL POLE. SEE FIXTURE SCHEDULE HANDHOLE TO FACE HARDS CAPE GROUND LUG ROUND BASE COVER PROVIDE NON-SHRINK GROUT UNDER BASE PLATE CONDU;T AND 'NIRE AS SHOWN ON PLANS 15' #4 BARE COPPER WIRE COILED IN BASE. NC SCALE ELECTRICA~ CONDUITS FINISH GRADE CMN STRUCTURAL ENGINEERS Page No. 1 Project Name: M_ass·on and __ Asso_c. c Trail Eiid~C::01-13 f(Pole: .. , :Vanna Dr..and:ciuhbiid -Vi}lage;' Cal'lkbad, cA By: CN Date: 2/20/2017 Seismic Load (ASCE 7-10 Eqn. 29.4-1) Fp= .4"'ap"Sds*W* (l+z/h) R/1 Exposure C y,., 100 mph a " C 2.5 Sds = O.fl. Risk Category= 1 "'0 lo ) K, = 0.85 at 13 ft We 450Jb. z/h = .0 K,c = . 1 Kd = 1' Fp: 0.27 W olt qh = .00256 * K, K.:t ){,i \f' = qh= .6*qau1,= 21.8 psf (Ult) 13.1 psf (ASD) 0.189 W 85.05 lb ASD A5D < 177.6 lb. Go 0.85 Dpole"' 0.33 ft D*q".5 = 1.54 Fixture= Pole= Force at= F= q,GCiA F oo!e = 13.1 X Wind Force Govern yo ·2. Fig. 29.5-1 ho · 13 ft. h/D = 39,4 Area ht. A*ht 1.5 13 19.5 6.S 6.5 42.25 Total=-8 61.75 " 7.7 .J.9 ft 0.85 2 8 177.56 lb.@ 7.719 ft Depth of embedment required for Norn;:onstrained CBC 2013 Section 1807A.3.2.1 Cannot use this formula where d>lZ' do 0.SA(l +(1 +(4.36h/A))".5) po 177.56 lb ho 7.7188 ft be 1.5 ft do '3.7 ft pp= 200 pd/ft 51:,: 246.67 psf Ao 1.123 dreq "" 3.69 ft -18" 4-S" Use 18 "dia. x 48 Deep pier with 4 # 4 vertical bars with 3 # 3 ties within top 8"@ 2" o.c and #3@ 12" o.c remaining. TRENCH WIDTH AS REQUIRED FOR CONDUITS. BACKFILL MATERIAL, THE MATERIAL USED FOR BACKFILLING THE TRENCH ABOVE THE SHADING MATERIAL AND EXTENDING UPWARD TO THE SUBGRADE SHALL BE FREE OF ROCKS OR CLODS LARGER THAT G" IN ANY DIMENSION. THE COARSE MATERIAL SHALL BE WELL DISTRIBUTED THROUGHOUT THE FINER MATERIAL. THE AMOUNT OF ROCKS OR CLODS SHALL BE LIMITED, IN THE OPINION OF THE INSPECTOR. THE BACKFILL MATERIAL SHALL MEET THE REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES AND CITY STANDARDS AND BE FREE OF DEBRIS AND ORGANIC MATTER. SHADING MATERIAL AND INSTALLATION, NATURAL SAND, MANUFACTURED SAND, DECOMPOSED GRANITE, ROCK FREE SANDY LOAM, EXISTING NATIVE MATERIAL OR COMBINATION THEREOF. AGGREGATE MATERIAL SHALL BE CAPABLE OF PASSING THROUGH A /2" SIEVE. GRAVEL SHALL NOT AMOUNT TO MORE THAN 50% OF MIXTURE. SCREENING OR OTHER SUITABLE MEANS MAY BE REQUIRED AT THE INSPECTORS DISCRETION. THE EARTH TRENCH BOTTOM SHALL BE STABLE WITH A UNIFORM GRADE CONTAINING NO HARD CLODS, ROCKS, AND ETCETERA. THAT M.AY DAMAGE THE CONDUIT. IF IN THE OPINION OF THE INSPECTOR, THE CONDUIT MAY BE DAMAGED DURING COMPACTION, A 3" SHADE OF MATERIAL ABOVE AND BELOW THE CONDUIT MAY BE REQUIRED. COMPACTION, SHADING AND BACKFILL SHOULD BE COMPACTED !N ACCORDANCE WITH GOVERNMENTAL AGENCIES AND SHALL HAVE A MINIMUM OF 90% RELATIVE COMPACTION. VER!FY REQUIREMENTS WITH INSPECTOR. NOTE TO CONTRACTOR, MAINTAIN PROPER SEPARATION FROM ALL WET AND DRY UTILITIES PER THE CITY OF CARLSBAD AND SDG<E. E TRENCH AND CONDUIT INSTALLATION DETAIL NOTE TO PLAN CHECK, SIGNAGE TO Be' APPROVED UNDER SEPARATE PERMIT. DETAIL SHOWN FOR ELECTRICAL O~LY. PROVIDE RECESSED J-BOX AND WEATHER-TIGHT COVER. MAKE CONNECTION PER MAUFACTURER'S INSTRUCTIONS. TYPE 'D' LIGHT TYPE 'D' LIGHT I 2"Hx8"Wx30"L SQ. CONCRETE MOUNTING PAD RAISED 2" ABOVE GRADE. SECURE FIXTURE IN PLACE WITH 3/8" MOUNTING BOLTS. EPOXY IN PLACE. 3''-~..i SECTION VIEW FU LL CUT-OFF LED FIXTURE. SEE SCHEDULE. I 548 LUMENS. COORDINATE WITH LANDSCAPE. SEE DETAIL AT RIGHT. SIDEWALK/DG TRAIL ANCHOR BOLTS SUPPLIED W/FIXTURE CONDUITS$ WIRES -SEE PLAN 42" I l !B" ~_l_ 5GO-C-3250 P.C.C. BASE AGAINST UNDISTURBED OR COMPACTED (:35% MIN.) EARTH. _J 10" L ROUND C TYPE 'C' PEDESTRIAN LIGHT INSTALLATION DETAIL GRADE CONDUIT AND WIRING, SEE PLANS. ,\JO SCALf F PULL BOX INSTALLATION DETAIL CONCRETE UNDERGROUND PULL BOX. SEE SPEC. I /EL-I ~-ALL BELOW GRADE CONNECTIONS SHALL BE WATERPROOF. SEE SPEC. G/EL-1 10" I" ROCK BEDDING G" BEYOND SIDES OF BOX AND I 0" DEEP. 3'. INSIDE OF BOX. \ _;:,,' , "', <( u 0 0 ' . z <( .µ lU <,) cO (\) (f) (f) o' '-_J _J (L ~ DL ..illll <( 1--u (f) lU lU 1--> Lf) <( <( C\l Uz 0 Oo C\l (f) 1--(;) (f) 0 <( <( z u 0 -:r:: ~ z (f) 0 <( ~ 0 z -0 . ' 0 lU z .µ (f) 0 C (\) (f) 0 u u <( 0 (f) ..illll ~ C\l lU i... Rev1s1ons: i... Sheet Info: Drawn By: PJD Checked By, KPSR Scale, N/A Date• 03/0 I/ I 7 Job No., MAI I 4/03 I 2 I -CO I i... Sheet Title: DETAILS, PANEL SCHEDULE i... Sheet Reference: EL-3 Sheet: 5 of 7 ------------------ STATE OF CALl<aORNIA OUTDOOR LIGHTING CEC-NRCC-LT0,01-E IRev,,sed 04/16\ CAUFORNIA ENERGY COMMISSION • STATE OF CALIFORNIA OUTDOOR UGHTING CEC-NRCC-LT0-01-C !Revised 04/16\ • CALIFORNIA ENERGY COMMISSION . 1 • CERT!FICAT{ OF COMPLIANCE NRCC-LT0-01-E CERTlF!CATE OF COMPLIANCE NRCC-LT0-01-E Outdoor Liehtlng (Page 1 of 4) Outdoor Lighting (Page 2 of 4) ?rnjed'1,ame: TRAILS ENO A. Generai information Project Address: DONNA DRIVE AND CARLSBAD VILLAGE DR. CARLSBAD, CA 8 Total Illuminated HardscapeArea: 26,359 Phase of Construction: El New Construction □ Addition □ Alteration Outdoor Lighting Zone (LZ) □ LZ-1 □ LZ-2 ~ LZ-3 □ IZ-4 l I have confirmed with the AHJ which LZ applies to thls site. For default lighting zone designations, see Tltle 24 Part 6, §10-114 B. Lighting Compliance Documents {check box for each document included) For detailed instructions on the use af this and all Energy Efficiency Standards wmp/iance documents, refer to the Nonresidential Manual published by the Colifornia Energy Commission. li2I NRCC-LT0-01-E Certificate of Compliance 0 NRCC-LT0-02-E Outdoor Lighting Controls Certificate of Compliance 0 NRCC,LT0-03-E Outdoor lighting Power Allowance Certificate of Compliance □ NRCC-LT0-04-E Outdoor Lighting Existing Conditions Certificate of Compliance C. Summary of Allowed Outdoor Lighting Power 01 Sum Total ALLOWED Outdoor Lighting Wattage from NRCC-LT0-03-E, page 1 Alterations with NO increase of connected lighting load may instead use the allowed v..rattage from NRCC-LT0-04, page 2. Complies ONLY if Installed (Box 02)::; Allowed (Box 01) 2,254 02 Sum Total INSTALLED Outdoor Lighting Wattage from NRCC-LT0-01-E, page 3. I 628 D. Declara,ion of Required Installation Certificates Watts Declare by checking all Installation Certificates that will be submitted (Retain copies and verify compliance documents are completed and signed.) li1I NRCI-LT0,01-E -Must be submitted for al! buildings r.:3 NRCI-LT0-02-E -Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), to be recognized for compliance. E. Declaration of Required Certificates of Acceptance □ Field tnspector □ Field Inspector Declare by checking all of the Certificates of Acceptance that will be submitted. (Retain copies and verify compliance documents are comoleted and signed.) El NRCA-LT0"02-A-Must be submitted for outdoor lighting controls. □ Field Inspector F. Schedule of Luminaires Exempt from the Outdoor Lighting Power Requirements in §140.7 01 m Name or Symbol Description of exempt luminaire in accordance with the exemptions ?~JectName TRAILS END I DateP:ep,e,O, 2/20/2017 G. Schedule of 1,uminaires Exempt from the Cutoff Requirements in §130.2(b) ------------·--·--------------------.j 01 Name or Symbol -----,---- 02 --~-~~------ Description of exempt lurninaire in accordance with the exemptions f--------------1---------------------------------, H. Schedule of Luminaires Exempt from the Outdoor lighting Control Requirements in §130.2{c) m I m f----N-a_m_e_o_c_Symbol I Description of exempt luminaire in accordance with the exemptions ------------------··-··-----------------.j STATE OF CALIFORNIA OUTDOOR LIGHTING CEC-NRCC-LT0-01-E (Revfsed 01/16' CERTIFICATE OF COMPLIANCE Outdoor Lighting Project Nome: TRA.ILS ENO I. Outdoor Lighting Schedule and Field Inspection Energy Checklist 01 Name or Item Tag TYPE-A TYPE-B TYPE-C Luminalre Schedule 02 C:ornplete Lumtnaire Descrlptlon ~Ow 20 led Street Light ' 37w 20 led Pedestrian Light 22w Multi led Pedestrian Light I 03 50_0 37.0 22,0 Installed Watts 04 How wattage was determined "' □ □ <l □ 3 4 15 05 06 150 148 330 INSTALLED WATTS PAGE TOTAL: 628 CALIFORNIA ENERGY COW.MISSION • I Date Pmporcd: 2/20/2017 Location 07 Primary Function area in which the luminaires are installed (Outdoor Lighting Zone) , Automotive Hardscape Pedestrian Hardscape ' iPedestrian Hardscape Cutoff 08 BUG Rating Enter sum total of all pages (Sum Total INSTALLED Outdoor lighting wattage) into i NRCC-LT0-01-E, page 1. NRCC-LT0--01-E (Page 3 of 4) Field Inspector 09 628 CA Building Energy Efficiency Standards• 2016 Nonresidential Compliance April 2016 CA Bu riding Energy Efficiency 5tandard5 · 2016 Nonresidential Compliance April 2016 CA Building Energy Effo;iency Standards -2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA OUTDOOR LIGHTING CEC·NRCC-LT0-1)1-E (Revlsect 02/161 CALIFORNIA ENERGY COMMISSION • CERTIFICATE OF COMPUANCE NRCC-LT0-01-E Outdoor Lighting {Page 4 of 4) TRAILS END DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name, PHILIP DODGE 00<:um~ntation Author Sigristure: Visual Concepts !NC >1enature Date· 2/20/2017 Address: 4655 RUFFNER STREET STE.220 Ct/I, Certification ldentit,c:at,o~ (,foppkable) City/Slate/Zip: SAN DlEGO, CA 92111 Phone: 858-278-4503 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the. following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. I D.:o Pn,;,arod: 2/20/2017 IY 2:. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance spedfications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 2:4, Part 1 and Part 5 of the California Code of Regulations. 4. The building design features or system design features Identified on this Certificate of Compliance are consistent with the information provided on other appllcable compli~nce documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for appro1<al with this building permit application. 5. 1 will ensure that a completed signed copy ofthis Certificate of Compliance shall be made available wtth the building permit(s) issued for the building, and made available to the enforcement agency for all app!icab1€ inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. ..-- Responsible Designer Name, Milton C. Neiderhaus r Re,pons.blc Oe~ign~rS1gr,aturc ~ :;.:----....- Compar,v · Visual Concepts INC 02/20/ 17 Addres:; 7297 Ronson Rd. Suite C. E 8G3G City/State/Zip: San Diego, CA 92111 858-278-4503 I I ! CA Bullding Energy Efficiency Standards -2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA OUTDOOR LIGHTING CONTROLS CEC-NRCC-L T0,02-E (Revised 08/16) CALIFORNIA ENERGY COMMISSION • CERTIFICATE OF COMPLIANCE NRCC-LT0-02-E 1 Outdoor lighting Controls (Page 3 of 3) ProJectName· TRAJLS END i n»cP,,.,,.,~ 2/20/2017 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. , Dou.imentation Author Name; PHILIP DODGE Dou.tm<'.ntation A\Ilhc>r Signaturs,; comp.,ny, Visual Concepts INC Signdtwreoaie: 212012017 Address: 4655 RUFFNER STREET STE.220 CEA Certilicat,on ldentii,cauon (rl"appjic:able): aty/State/Zlp: SAN DIEGO, CA92111 Phone: 858~278-4503 RESPONSISLE PERSON.'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or '>)'Stern design identified on this Certificate of Compliance (responsible designer]. 3. The energy features and performance specifications, materials, cornf}onents, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The bwilding design featctres or system design features [dentified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) is.sued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of thls Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. ~ Resp,:,nsibleOe<igner Nam~ Milton C. Neiderhaus R~spo~sible Oes:gnerSlgnarure: _;.,--~~-~~e-a=-::: _:a,----------------1 Company Visual Concepts INC Date Sign~d 02)20/ 17 7297 Ronson Rd. Suite C. E 8G3G City/Slate/Zip: San Diego, CA 92111 Phone• 858-278-4503 CA Building Energy Efficiency Standards -2016 Nonresidential Compliance August 2016 ST A TE OF CAi..lFORNIA OUTDOOR LIGHTING CONTROLS CEC-NRCC-LT0-02-E (Revised OB/16) CALIFORNIA ENERGY COMMISSION • CERTIFICATE OF COMPLIANCE NRCC-LT0--02-E Outdoor Lighting Contro!s (Page 1 of 3) TRAILS END I Ca,e Prepar,d 2/20/2017 A. Mandatory Outdoor Lighting Control Declaration Statements Check a!I that apply: sf' lighting shall be controlled by s,':lf-contained lighting control devices which are certified to the Energy Commission according to the ntle 20 Appliance Efficiency Regulations in accordance with §110.9(a). □ Lighting shall be controlled by a lighting control sy~tem or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with §130.4(b). j..J" All lighting controls and equipment snail comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in ' ! accordance with §130.0(d). ! D Part-Night Outdoor Lighting Controls, as defined in Section 100.l{b), shall meet the requirements in Section 110.9{b )S. □ Ail outdoor incandescent luminaires rated over 100 watts, determined in accordance with Section 130.0{c), shall be controlled by a motion sensor. □ All outdoor luminaires rated for use with lamps greater than 150 lamp watts, determined in accordance with Section 130.0(c), shall comply with Uplight and Glare requirements in accordance with Section 130.2(b). 1/' All installed outdoor lighting sha!I be controlled by a photocontrol or outdoor astronomical time-switch control, or other control capable of automatically switching OFF in accordance with Section 13□.2[c)l. ~ All installed outdoor lighting shall be independently controlled from other electrical loads by an automatic scheduling control in accordance with Section 130.2(c)2. "'1ffl Ail installed outdoor lighting, where the bottom of the luminaire 1s mounted 24feet or less above the ground, shall be controlled with automatic ligl1ting controls in accordance with Section 130.2(c)3. D For Outdoor Sales Frontage, an automatic lighting control shall be installed in accordance with Section 130.2{c)4. , D For Building Facade, Ornamental Hardscape and Outdoor Dining lighting, an automatic lighting control shall be installed in accordance with Section 130.2{c)S. '..J' Before an occupancy permit is granted for the newly constructed building or for the addition, or for any altered outdoor lighting, the outdoor lighting controls shall be certified as meeting the Acceptance Requirements for Code Compliance in accordance with §130.4.(a). Outdoor lighting contro!s shall comply with the applicable requirements of Section 130.2(c} and Reference Nonresidential Appendix NA7.8. CA Suildir,g Energy Effic;em:y Standards -2016 Nonresidential Compliance August 2016 STATE OF CAL!FORNIA OUTDOOR LIGHTING POWER ALLOWANCES CEC-NRCC-LT0-03-E {Revised 01116\ CALIFORNIA ENERGY COMMISSION • CERTIFICATE OF COMPLIANCE NRCC-LT0-03-E Outdoor Lighting Power Allowances {Page 1 of 4) >rcj<!<J:1"'ina, TRAILS ENO I Da.e,re,aced: 2/20/2017 A. OUlDOOR LIGHTING POWER ALLOWANCE SUMMARY 1. General Hardscape Lighting Power Allowance [Site Tota! from Section B of NRCC-L T0-03-E) 2. ACdrtion.al Specific "use it or lose it" Lighting Power Allowances listed in each of these cells shall be identical to total allowed watts determined in Section C-1 to C-4 of NRCC•lT0-03-E PER APPLICATION from Section C-1 I PER UNIT LENGTH (SALES FRONTAGE) from Section C-2 PER HARDSCAPE AREA (ORNAMENTAL UGHTING) from Section C-3 i r >----------0-, • lf----------0-, 3. Sum Total ALLOWED Outdoor Lighting Wattage [add rows 1 and 2} B. GENERAL HARDSCAPE LIGHTING POWER ALLOWANCE FROM TABLE 140.7-A PER SPECIFIC AREA from Section C-4. ,_ 2,254 0 2 0 3_ 2,254 I Area Wattage Allowance {AWA) Linear Wattage Allowance {LWA) Initial Wattage Allowance (IWA) I Total General Hardscape ! : Lighting Allowance ! 01 Name of Area Parking/ Drives Pedestrain Hardscape 02 I lli11minilted j rlilrd>cape Area I --1 14,069 I 12,290 I 03 , AWA Per Sou'<lre Foot U,040 0.040 04 I :AWA (B02 ~ B03)! 563 492 05 Perimeter Length of Generol Hordscope i 1,100 0£ l?A per linear Foot 0.350 0.350 f------j' :-1 ------j :------, CA Building Energy Efficiency Standards• 2016 Nonresidential Compliance 07 LWA (BOS x 806) 295 385 520 0 08 IWA (Watts] ! 09 S04 + 807 + BOS 1,378 877 i TOTAL 2,254 January 2016 STATE OF CALIFORNIA OUTDOOR LIGHTING CONTROLS CEC-NRCC-LT0-02-E /Revised 081161 CERTJFICATE OF COMPLIANCE Outdoor lighting Controls B. Mandatory Outdoor Lighting Control Schedule and Field Inspection Checklist Outdoor lighting Control Schedule 01 Location and Application of Luminaires Being Controlled TYPE A STREET LIGHT TYPE B PEDESTRIAN LIGHT TYPE C WALKWAY LIGHT 02 Type/ Description of Lighting Control (Le. outdoor motion sensor, outdoor photocontrol, outdoor astronomlCal time- switch control, automatic scheduling control, part-night outdoor lighting control) 'PHOTOCONTROL 'PHOTOCONTROU occ_ SENSOR : PHOTOCONTROU acc. SENSOR CA Building Energy Efficiency Standards• 2016 Ncnresidentlal Compliance STATE OF CALIFORNIA OUTDOOR LIGHTING POWER ALLOWANCES CEC-NRCC-LT0-03-E !Revised 01.116) CERTIFICATE OF COMPLIANCE Outdoor Lighting Power Allowances PrcjoctNam~, TRAILS END DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Oocumenta:ion Author ~amr: PHILIP DODGE Visual Concepts !NC Address: 4655 RUFFNER STREET STE.220 Oty/Sts1te/Zip, SAN DIEGO, CA 92111 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance fs true and correct. CALIFORNIA ENERGY COMMISSION • 03 # of Units 3 4 15 04 :,: N 0 m ~ ~ I DatePrepared: 2/20/2017 Standards Complying With (✓ all that apply, or enter 'E' if Exempted) 05 06 07 08 NRCC-LT0-02-E ' (Page 2 of3) 09 10 11 Pass Fail □ □ □ : □:: □ □ □ □ ,□ . .!--' □ □ -□·: □ August 2016 CALIFORNIA ENERGY COMMISSION • NRCC-LTD-03-E {Page 4 of 4] I Date Prepared: 2/20/2017 , D<>cumen.at,on Author S,gnature: 5,g~ature Date:212012017 ' CEA Certification lde~tffica.ion Iii apolicable): 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible deslgner). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identiAed on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regl.llation.s. 4. The building design features or system de.sign features identified on thls Certificate of Compliance are consistent with the information provided on other applicable compliance doc1.ments, worksheets, calculations, plans and specifications .submitted to the enforcement agency for approval with thls building permit application. 5. I will ensure ~hat a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for al! applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. ~ Resp,:,nsibleD2Srg.~HNam,,• Milton C. Neiderhaus ResponsibleOe,;icnerSigeature· _ _ Visual Concepts INC Date Srgned: 02/20/17 7297 Ronson Rd. Suite C. license: E 8G3G City(S,atef!iµ: San Diego, CA 92111 Phone: 858-2784503 CA Building Energy Efficiency Standards· 2016 Nonresidential Compliance January 2016 _µ \) \l) o' '-(L _µ C \l) (_) ...ii 0 z \j_J (_fl _J ~ 1--- (_fl <( u 0 <( cO (_fl _J De'. <( u \j_J \j_J ~ :;: Uz Oo (_fl 1--- (.f) 0 <( z 0 z <( z 0 (_fl (_fl <( 2 :r:: (_fl ~ \j_J 0 0 (\J ~ Rev1s1ons: lf) (\J 0 (\J G") <( u 0 0 0 z 0 u (_fl \j_J ~ Sheet Info: Drawn By, P JD Checked By, KPSR Scale, N/A Date, 03/0 I/ I 7 Job No MAI 14/03 I 21-CO I ~ Sheet Title: TITLE 24 ~ Sheet Reference: EL-4 Sheet, 6 of 7 _J ::;, 2 / 0 N FOUNDATION TO BE 2" ABOVE GRADE GRADE\ 1~ ""' I 48" I • 24" • I I -FULL C UT-OFF LED E SEE FIXTUR SCHED ULE. ROUND 5 TEEL POLE. PROVIDE GROUT U PLATE NON-SHRINK NDER BASE IJlo TYPE 'A' STREET LIGHT. FOUNDATION TO BE 2" ABOVE GRADE GRADE 1%]-o FULL CUT-OFF LED FIXTURE. SEE SCHEDULE. HOLD FOUNDATION DOWN THICKNESS OF SIDEWALK. POUR SQUARE CAP AFfER SIDEWALK IS POURED OR MONOLITHIC WITH SIDEWALK. COORDINATE WITH LANDSCAPE. SEE DETAIL ABOVE. SIDEWALK 48" 24" FULL CUT-Off LED FIXTURE. ROUNDSTEEL POLE. TYPE 'B' AREA LIGHT. PROPERTY LINE 42" J 18" r-.-1oc-l l ROUND Q) TYPE 'C' BOLLARD LIGHT. •J.C •),J C.l' •J.C c.u 'J.O r .C 0.{l '·" n.o s.r. 0,J G.O '·" ,.c c.c C./J L.C ,·.c 'J.S C.l :.c :.o O.D 1.U ::c co ,J.O -:.c 0.0 r .e c,c C.G c.c c.o c.c L',C c.c c., c.t c.G J.r U.C e.c C. 1 J.l" ·J.: c.r r.o e.c 'J.l' c.e "-" C.'J o.J e.c I o. ·, I I •).~ i I (;.,Ji I I 0.J t I O.•J/ i I <:p o.v1 I ' I 0-1 ' , __ ;:l d ' I er 'f I I~ dr / I / I/ "IF : "f' "' I I ,., I (, I I I I I v.u r.c C .C ., r.., D ,J l,.0 0 'J 0.0 C,J r,.u C.c (',) :.c o.c "·" (l.) 0.1 ., :.L' (,.(I '·" ,-.n NOTE: LIGHT TRESPASS 20' BEYOND PROPERTY LINE IS 0.0 FOOT-CANDLES PROPERTY LINE ,., '·' c.r J.f "·' '., c.c ,:,,_ S.1 Q.U (,.C c.c CJ, , .. (' C .C ,;.c C .C c C CJ, ,_, r .. s , .c PROPERTY LINE ,_,.J C,l ,.c C.(. ' \ \ \ \ \ \ \ \ \ \ C'.C \ \ \ \ \ \ \ I..G r .G \ \ \ \ .. ,.0 a.o \ \ \ \ \ \ \ \ \ \ ' \ \ \ \ \ \ \ \ ' \ \ 0.(1 "' ,·.t c_o \ \ \ \ \ \ \ ; -,.r \ \ \ ' c.c I •l.O '.i'' I I u,c c.o s.o ,1_J "-" c.c I / 0 // .,.o / / ,r n_o o·• ''C /'·'' r,_o o., c.o / / c.o 1 r e,<1 n, ;./,., / ,, 0 "-J/ ::.c / / "'-'l ,.n -:.c (;.\: / • .. J / I , ; /c:.o '-'; / I C.0 (.(• J.l" ?< C'.0 '-,CJ J.J I / c.t r.o J.;>" 0.: c..e co I / u ·J.O ,1.1 c.r, c.v// ·J.J o.J G.~ c,_o '·" J.t t.' / ,,_, r.r. /{_,-o_o c..J r.o e_c o_o c.c '-0 / 7{ r:.r o.3 o.·J 0.r· e_c o.; •J.: / / oj J.c c.c o., ~-•J r,.c c.o o.o •].fl O.J O.J// O ·l / / C.0-C.O ~-~ (."' /C.~ O.J / / C.l O.'J r/1 J." (l.•J / / o.o c.,1 c.c c,;/ c.,• J.a 0.1 I / o.c Q.·J r.n ·r/ n.r c-'J 1.0 "-'' I I o." , .. ~ ,.c //;.~ ,,.r c•.·J ~.J 0.(1 I i.o c.c o.o r.o ;{ :.r c.n n.0 "-' o.~ / / •1.1 C.0 \,C 0.~ O_jl CC / I :.n ,.r n.o// r•.c co c.r o_o I I /1.-1 / r.r; •).) (J.Q "·' c.c ,t., "·" '.c (J_Q / I >' C,l' 0.0 / l" .0 l.J ~-" '·'··'// ;." ,.c (,.,, o.o c.e c.o ,1_\ 1,.0 I I ,•_o /c., C.O C.( "-" / / C.C L".O S.G J.r "·' U.J ,c a.r / / / / / / / / / / / / I / / / I I / / / I I c.c r:.c c.,; 1.-f_o ,1.; ·.c c,c e.o I I I / ,, 0 ' 0 ,_,. C.C / / / ,.c "·" c.o / I / ,.o / / O' 10' 20' NORTH SCALE, 1 "-20'-0" ► TYPE 'D' MONUMENT LIGHT. TYP. I 1%]-o TYPE 'B' AREA LIGHT WITH MULTI-LEVEL OCCUPANCY SENSOR. TYP. 4 TYPE 'C' BOLLARD LIGHT, 42" HEIGHT WITH MULTI-LEVEL OCCUPANCY SENSOR. TYP. 15 IJlo TYPE 'A' STREET LIGHT. TYP. 3 40' Under ground Service Alert of'~eo.Uf"""'""'- CALL TOLL FREE 1-800-277-2600 TIJO IJORKING DAYS BEFORE YOU DIG ;"':. \. ,\- ''•, 0 z lLl lf) _J lf) lLl ~ <( u 0 <( cO ~ ck'.'. <( u lLl > <( Uz Oo lf) 1- lf) c..'.) <( z 0 z <( z I: lf) ~ Ss lLl lf) 0 <( 0 ~ C\J 1111.. Rev1s1ons: lf) C\J 0 C\J (J) <( u 0 0 0 z 0 u lf) lLl 1111.. Sheet Info: Drawn By, P JD Checked By, KPSR Scale: I "= 20' Date, 03/0 I/ I 7 Job No., MAI 14/03121-CO I 1111.. Sheet Title: PHOTOMETRIC PLAN ho.. Sheet Reference: EL-5 Sheet, 7 of 7