HomeMy WebLinkAbout2722 SOCORRO LN; ; CB890916; Permit"' z 0 ~ a: C .., u ... 0
a:
I[
0 u
a: ... 0 ..,
5 ~ ... z ~
zl Q >--;
~' z w ... :I 0 u
!" a:: ...
"' a: 0 31:
il
0 I hefeby affirm that I am licensed under
provlalon1 of Chapter 9 (comm<1nclng with
Section 7000) of Division 3 of the Business
and Prof .. 1lons Code, and my license is In
full fo,ce and effect.
I hereby a1twm IN:t I am exempl from lhe Cont,ac· lor s Locense L•w lor the lollow1119 ruson ( Sec 7031 5
Business and Professt00s Code Any city or cCNJnty whttli re quues a perm,1 10 construe!. alter. improve. Otmoltstl or repair any structure poor 10 its cs~nce al.so requires !he ap phunt for such permn 10 file a 519.ned statement that he tS
licensed pursuant lo !he prov1s,ons ot !he ContrKIOr' s L1eense law (Chapter 9 commencing with Sechon 7000 01
():v1saon 3 of the BuSU'N!SS ancl Protessaons Code, Of 1na11s ex empt lhefetrom ano the ba~s tor lht ~lege(I e11etnp1Km Ant
Vt<Uhon ot Section 7031 . !> by an applant lor a pe,m,t sub
1ec1s 1he applanl to a CN1I penalty of not more than live liun
dfed dollars ($5001
1. as owner ol the propeny. or my employees wllh waoes
as lhe1r sole eompensatt0n will do !he work. and lfle strut·
ture tS not inlended or offered lor sale fSec 7044 Business atKI Profession~ Code The Con1rx1or· s tacense L~w dots
not appty 10 an owner of property who bt.ulds Of 1mprOVtS
thereon and who does such w01k htmsell or lhrough his own
emplOyeeS. prO'Ytded thal such 1mprovemen1s are not intend~
ed or ottlt'ed few sale If. hOweYer the Du11dtng 04' tmprM ment 1s SOid w1lh1n one yeil' DI comp,et.on. the owner~bt,ulder
will have lhe burden of provmg lhal he did nol butld Of 1m•
prOYe lor the purpose or sa1t1
I. as owner ot the Pfoperly. am exclusively contracting w11h hcensed con1rac1ors 10 construe! the prOJeCI (Sec 7044
Business Jnd Protess100s Code The Contractot's License Law does not appty lo an owner of property who bu1'ds or IITt
prOYeS thereon. and who contracts lor sach ptote(:IS with a conlraclcw(s) hcense pursuant to the Contraclor's license Law)
l As • nameowntt 1 ,m ,mprovmg my home ,oo the tallow mg conc:hhons exist 1 The wcwk Is being perf0<med pr,o, to salt
2 I have llved in my home for hlfefve monrhs
pnor to completion of Uus WOfk 3 I have not clamed this exemption during the las! lhree years
O I ,m exempt under Sec _____ _
tor this reason B&PC
0 I hereby affirm that I have a cert1hcate of consent to
self-insure or a cer11hcate ol Workers Compensation In.
surance or a certified copy thereol (Sec. 3800, Labor Coc:»I
POLICY NO
COMPANY
:J Copy IS filed With the c,1y
D Cectihed copy Is hereby furnished
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be compfeled if the permit
ts tor one hundred OOllars (S H>O) Of less)
C I cer11ty !hat 1n the peflo,mance of the work tor which
1h1s permit 1s rssued. I sh.a.II not employ any pe,son in any
manner so as to beeome subject to the Workers· Compen-
sattan Lllws of Cahtornia
NOTICE TO APPLICANT II, alter making this Certificate
of Exemption. you should beeome subject to the Workers
Compensaoon provisions of the Labor Code, you mu.st
lonl'lw1th comply with such pt'O't'Is1ons or 1tus permit shall
be deemed revoked
D I hefeby affirm that there 1s a conslrucUon lenc:hng
agency ICM' the performance ot the wortt for whteh thrs per
m,t Is issued {Sec. 3097. C1v11 Code)
Lender s Name _
Lenders Address
USE BALL POINT PEN ONLY & PRESS HARD ---APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS. ··-·-·-----· ---·---·--
CARLSBAD BUILDING DEPARTMENT APPLICATION & PERMIT 2075 Las Palmas Dr., Carlsbad, CA 92009-1915 (619) 438-1161 ..
JOB ADDRESS AV ST_ RD-THOMAS BROS NO . l1:i-~~r~:;t5I · BUSINESS LICENSE • VALUATION PERMIT NUMBER
. ,;," 7-2;2. --~ r. c-u £...k(J l/ .k;' ,;{,,C"_ . >1,~ ',/_
LOT BLOCK I suB01v,s,oN I ASSESSOR PARCEL NW...? /kco;_r;;-t3cJJ LL) W.j
CONTRACTORS PHONE• ZONE r!-6 ( y o ~✓c. .:>21..:5"--07 28'2-~JY.3 OWN£ R'S NAME I OW .. EA'S PHONE
7-~AVR,;~M~e STATE LICENSE NO. BUILDING SO. FOOTAGE
£.~ ~/-3~/t,
o:;i7i~ADD:rc>CcJ/Z/Zo L~,;s-DESIGNER DESIGNER'S PHONE
D~R•!.,T '..~~AK ~~ r~. ½-"~. ,.~I.,( ·~ DESIGNER'S ADDRESS ST4TE LICENSE NO.
r~-r..-/ 1,._' ( /_;j';,zK
8357 07/18/89 0001 01 02
3-.:;D~ i-( ) /'~ fj f u. A BldPmt 523-0C ' . --F p F LR ELEV NO OCC GP EDU
,/fu/,v I / STORIES
vO NO
~ CENSUS TRACT I PARKING SPACE I RES UNITS I GRADING PERMIT ISSUED I REDEVELOPMENT TYPE OCC LOAD FIRE SPA AREA CONST
y D ND vO NO vO NO Not V~l,d Un~s Abe/Jin, C,rtdr"1
QTY. PLUMBING PERMIT · ISSUE -=,-so QTY. MECHANICAL PERMIT · ISSUE iflc;C) SUMMARY/ACCOUNT NUMBER
'-1' EACH FIXTURE TRAP INSTALL FURN DUCTS UP TO 100.000 BTU l!UILUINI,; l'tHMI 1 UU l ·B lU·UU·UO·oau '/-..i/
I EACH BUILDING SEWER OVER 100,000 BTU SIGN PERMIT 001 ·810·00·00·8221
EACH WATER HEATER ANO OR VENT BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 001 ·810·00·00·8891 -29;,
EACH GAS SYSTEM I TO 4 OUT LETS BOILER/COMPR ESSOR 3 15 HP TOTAL PLUMBING 001 ·810·00·00·8222 -1"1-
EACH GAS SYSTEM 5 OR MORE I MET AL FIREPLACE ELECTRICAL 001·810·00·00·8223 _...
EACH INSTAL . ALTER, REPAIR WATER PIPE I VENT FAN SINGLE DUCT MECHANICAL 001-810·00·00·8224 2(P
EACH VACUUM BREAKER ME CH EXHAUST HOOO DUCTS MOBILEHOME 001 ·810·00·00·8225
WATER SOFTNER RELOCATION OF EA FURNACE1HEATER SOLAR 001 ·810·00·00·8226
EACH ROOF DRAIN (INSIDE) DRYER VENT STRONG MOTION 880·519·92·33 f
TOT.I.L MECHANICAL FIRE SPRINKLERS 001·810·00·00·8227
TOI AL PLUMBING I , r . ) -PUBLIC FACILITIES FEE 320·810·00·00·87 40
~00 BRIDGE FEE 360·810·00·00·87 40
QTY. ELECTRICAL PERMIT · ISSUE QTY. MOBILE HOME SETUP PARK·IN·LIEU (AREA )
NEW CONST EA AMP SW! BKR CAR PORT TIF 312-810·00·00·8835
I PH 3 PH AWNING LA COSTA TIF 311·810·00·00·8835
EXIST BLOG EA AMP SWT BKR GARAGE FMF
I PH 3 PH LICENSE TAX 001 ·810·00·00·8162
I REMODEL ALTtR PER CIRCUIT MFF 880·519·92·57
TEMP POLE 200 AMPS
OVER 200 AMPS
fEMP OCCUPANCY 130 OAYSl -
CREDIT DEPOSIT ,. .... > ,.
TOTAL ELELlRILAl I 11>. TOTAL TOTAL FEES PAYABLE I ti
_.1---.J
I HA'IE CAREFULLY EXAMINED THE COMPLETED APPLICATION ANO PERMIT AND DO HEREBY E•p,rahon Every perm,r 1S1uedbrlhelk/lldingOlhc:telundlt1Nprov1S1C1Mofl,,,_ * AN«-tAPERIIIIT.MQUIMDFOlllXCAVATIONS011£11 CERnFY UNDER PENALTY OF PERJURY THt.T All INFORMATION HEREON INCLUDING THf Code 111811 e•p,re by l,m,w,on...., -null--",,.. building or_.. t· 0-DIP AND D8IOUTION 091 CONSTRUCT10N Of aulhonzed by such _m,r ,s "ot commenced -180 daya from Ille -Ol auc:t, DECLARATIONS ARE TRUE AND CORRECT ANO I FURTHER CERTIFY AND AGREE IF A PERMIT I~ perm,r. "' ,1 the build•::x or wort, autllonMCI by IUCh -mt1 ,s or STIIUCn.s OVER 3 STONES IN HEIGHT
ISSUED TO COMPLY WITH ALL CITY COUNl Y AND STATE LAWS GOVERNING BUILDING CON ilhandnnecl at anv tune a e, the WOik 11 --to, a w.oo of 11111 ..__ -
STRUCTIQN WHETHER SPECIFIED HEREIN OR NOT I ALSO AGREE TO SAVE INDEMNIFY A~ . _ _ -··-·-AO APPfjOVED BY DATE • KEEP >iARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABIUTlfS, JUDGMENTS. COSTS ANO A .. T S ~ CONTRA:x ~ EXPENSES WHICH MAY 'IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THf ~ ,.
1/1-/fJ GRANTING OF THIS PERMIT -;: , vr I f .. BY PH E 0 1\.,../e; -✓ I
ii
~ u:
>-;;;
0 a.
E Ql ~
I
'O 0 <.?
C "' u
a. a. <(
I
.:,;,
C a:
0
r/)
r/)
Ql r/)
r/)
<(
I
~ 0
ai >-
Ql u
C "' C u:
C
Ql Q) <,
0
ti Q) a. r/)
C
~
.c ~
• . ~
t
TYPE I DATE INSPECTOR
BUILDING I
~ I
FOUNDATION "'-L /)
REINFORCED STEEL 1""-. I /;s-/Pi T
MASONRY I I I I
GUNITE OR GROUT I
SUB FRAME D FLOOR D CEILING
SHEATHING tJ ROOF D SHEA~ /1
FRAME I 'e/11r1-/
EXTERIOR LATH I
INSULATION I
I
INTERIOR LATH & DRYWALL I
I .
PLUMBING I
D SEWER AND BUCO D PUCO
UNDERGROUND D WASTE D WATER 1/;r-lJ'J p/")
TOP OUT D WASTE D WAT}:R J{)/;(/Y} /./
7
TUB AND SHOWER PAN I , I
GAS TEST I
I
D WATER HEATER D SOLAR WATE;R
I
ELECTRICAL I
I
D ELECTRIC UNDERGROUND D UF)=ER /)
ROUGH ELECTRIC I ;o/J/;-, v
D ELECTRIC SERVICE D TEMPORAAY
D BONDING D POOL I
I
I
MECHANICAL I
I /"\
D DUCT & PLEM., D REF. PIPING 1 /b/"1/)-1 r--,L../
HEAT -AIR COND. SYSTEMS I I
VENTILATING SYSTEMS I
I
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE
ITEMS ABOVE HAVE BEE_NAPPR_Ov_ED. __
FINAL I
I
PLUMBING "'-I
ELECTRICAL " I /)
MECHANICAL " I I _/11 b rr
GAS "I t,/1 )f ' I
BUILDING 1'. I
SPECIAL CONDITIONS I
I
"
,.
{!11:, <a-9 0~ (Jo •
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPECTIONS INSPECTOR'S NOTES
INSPECTION REO IF INSPECTORS DATE F£1ff. /:=~"'--.L)(!C/t::.._ .J--..s-ou1z-5 10/3 CHECKED APPROVAL ,
SOILS COMPLIANCE
PRIOR TO -
FOUNDATION INSP -~
STRUCTURAL CONCRETE
OVER 2000 PSI
PRES TRESSED
CONCRETE "
POST TENSIONED
CONCRETE
FIELD WELDING
HIGH STRENGTH
BOLTS -
SPECIAL MASONRY
.
PILES CAISSONS
.
-.
' r ~ --, r r
.
~ ·--,
.
,· . . . ' . -
., .
..
PERMIT# CB890916
DESCRIPTION: 850
137
CITY OF CARLSBAD
INSPECTION REQUEST
FOR 06/13/90 INSPECTOR AREA TP
PLANCK# CB890916
OCC GRP
SF BED/BATH/FAMILY ROOM
SF DECK SCHOOL FEES NEEDED -SMSD
TYPE: RAD
JOB ADDRESS: 2722 SOCORRO LN
APPLICANT: IWANS, SCOTT
CONTRACTOR: PROJECT BUILDERS
OWNER:
REMARKS: Tl/MH/BARBARA/438-2908
SPECIAL INSTRUCT: AFTER 1
30
TOTAL TIME:
CD LVL DESCRIPTION
19 ST Final Structural
29 PL Final Plumbing
39 EL Final Electrical
49 ME Final Mechanical
CONSTR. TYPE NEW
STR: FL: STE:
PHONE: 619 944-9626
PHONE: 619 282-J343 \
PHONE: / ";)
INSPECTOR ----'-/-----,,~'4"""'-+
1
_____ _
ACT COMMENTS
_%_ ________ _
f----
***** INSPECTION HISTORY *****
DATE DESCRIPTION ACT INSP COMMENTS
060790 Final Combo NR TP
053090 Final Combo NR TP NO RESPONSE
032890 Final Combo co TP SEE INSP. CARD 032390 Final Combo NR TP NO RESPONSE
112889 Shower Pan/Roman Tubs AP TP
103189 Exterior Lath/Drywall co TP
103189 Interior Lath/Drywall AP TP
101989 Sewer/Water Service AP WM
101989 Sewer/Water Service AP WM
101889 Sewer/Water Service co TP
101689 Insulation AP TP
101689 Insulation AP TP
101389 sewer/Water service co TP
101089 Insulation co TP COULD NOT GET IN
100389 Frame/Steel/Bolting/Welding NR TP
100389 Rough Combo AP TP
100389 Ftg/Foundation/Piers AP TP DECK AND STAIRS
092589 Rough Combo co TP
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: 7 -/ -fi.3,,_
JURISDICTION: 6& g JP
QFILE COPY
QUPS
QDESIGNER
PLAN CHECK NO: ~8~'.z_-~/_J_0 ____ S~E~T~:~~/~/ __ _
PROJECT ADDRESS: 2-. 7 z_ 2_ SOC c., v Y 0
PROJECT NAME~ S:P-tf) ~ lvi
□ The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply J2?l_ with the jurisdictipn'snbuilding codes when minor deficien-
cies identified ·~~ are resolved and
□
□
□
□
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans a~e being h~ld 2t Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
rv(Esgil staff did not advise the applicant contact person that A plan check has been completed.
□ Esgil staff did advise applicant that the plan check has
been completed. Person contacted: --------------
By~&~-Enclosures: __ _ -□GA □AA Ovw ODM
DATE:
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-14-68
JURISDICTION: (\, r /c, fJ q_£ jPLAN CHECKER
□FILE COPY
[JUPS
CDESIGNER
PLAN CHECK NO: 89-9/G SET: r
PROJECT ADDRESS : __ A----'-7...L..<Y:<----L=--'~'"""o'--~c=~'---'c"--..,_v---'r-"c-' _,__,.l="''--'-----
1 I ·' I ' 1 --I / I PROJECT NAME: -SF l) /-doi, · ,::; ,,., J~ . .,. J;~, K L-U:".'./
D
D
D
I
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-cies identified _____________ are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
[AA"The check list transmitted herewith is for your information.
l!.C!-._The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
®The applicant's copy of the check
:Sc.dt+ :Cwf\f\JS
list has been sent to:
a
/ 5S W, :;rAsorv Si-re et tt= I:).
leu.CA.diAJ cA f'J..oa'f-
ProJ e..c..f: 5 u; w~ .
AH-n' C. kr;s /.(Uf''\S
c, 3 ~;~ Riyee..&,a,Le. s+re-e.+
SAN c:~o~ Cft 9 ')..J ::i.o
Esgil staff did not advise the applicant contact person that
plan check has been completed.
O Esgil staff did advise applicant that the plan check has
been completed. Person contacted: Sco-r I .z WA NS
Date contacted: ________ Telephone # 9 £/tf.-'} 6 -;2..._ (p Sc.oi+ ~vJ/WS
0 REMARKS: .2.'t~-'z'.3't3 d.rjs k.lA.fft.S
By£,L) ~£ ESGIL CORPO~ON
□GA □AA □vw ODM
Enclosures: -----------
JDRISDICTIOll:_0..-=--wl---"-~1/ ~L-~~~--
E!ICLOSURES: _________________ _
PRO.JJ!CT ADDRESS:
I
2 7 ;:2._ 2-Sc,,c ,:..-'v rD L ,.l
FLOOR AREA:_.,..@'--6--=0 ________ _
S'.IORIES: __ /~-------------
HEIGIIT:. __ .::.c......_..a_._~ __________ _
~= ------------------
PLAII IXlRRl!CTIUlf SBKET
SIIIGLE FAMILY AIID DllPLEK ™ELLillGS
I t
;;:;;7/Ji, 7!;:i;::.J ~ de
Applicant contact person:
~C£d_/ Telephone: 9C/ l/<JG,;2_{.,,
FOREWORD: PLEASE READ
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances by the Planning Department,
Engineering Department or other departments.
Present California
construction comply
model codes:
law mandates
with Title 24
The
1985 UBC (eff. 7/31/87)
1985 UPC (eff. 3/30/87)
1987 NEC (eff. 10/28/87)
1985 UMC (eff. 8/28/87)
above regulations apply
that residential
and the following
to residential
construction, regardless
adopted by ordinance.
of the code editions
The circled items listed need clarification,
modification or change. All items have to be
satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec.
303(c), 1985 Unform Building Code, the approval of
the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, note on this list
(or a copy) where each correction item has been
addressed i.e., plan sheet, specification, etc. Be
sure to enclose the marked up list when you,submit
the revised plans.
BOIE: PA.GK lllJIIIERS ARE NOT Ill ~ENCE AS PAGES HAVIIIG l«l Il»IS 11DDn.; OORRl!CTIOIIS llm1I! DXIF!'.ED.
List No. 60, General Single Family Dwelling and Duplex Without Supplements. (1985 UBC)
G
,3.
J5.
Q
Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, California 92123,
(619) 560-1468.
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
Indicate on the Title Sheet of the plans, the
name of the legal owner and name of person
responsible for the preparation of the plans.
Section 302(a)7.
All sheets of plans must be signed by the
person responsible for their preparation.
(California Business and Professions Code).
Plans, specifications and calculations shall be
signed by the California state licensed
engineer or architect responsible for their
preparation, for plans deviating from
conventional wood frame construction. Specify
expiration date of license. (California
Business and Professions Code),
Specify on the Title Sheet of the plans the
gross floor area of each element of this
project including dwelling,_. garage, carport,
patio, deck and balcony. Section 302(c).
Provide a statement on the Title Sheet of the
plans that this project shall comply with Title
24 and 1985 UBC, UMC and UPC and 1987 NEC.
Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes'. Show finish floor elevations and
show elevations of adjacent finish grade.
Show drainage patterns with minimum slopes.
Section 302(c).
Indicate distance
proposed building.
from property
Section 302(c).
lines to
5/10/89
13'.
/ 14.
15:
I
ii,.
/
Show on the title sheet all structures, pools,
walls, etc. included under this application.
Any portion of the project shown on the site
plan that is not included with the building
permit application filed should be clearly
identified as "not included.11
Clearly show if the lower level is a basement
or a story, based on the definitions in
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension
the distance to the floor above, for story
determination.
FIRE PROIEClluH
Exterior walls closer than 3 feet to property
lines shal~ be one-hour rated construction and
have no openings. Such walls shall have 30
inch parapets when the building floor area
exceeds 1,000 square feet on any floor.
(Table 5-A, Section 1709 (a)).
Projections, including eaves, may not extend
more than 12 inches into the 3 foot setback
from the property line. Section 1710.
Eaves over required windows shall be
than 30 inches from the side and rear
lines. Section 504.
not less
property
Plastic skylights shall not
within 8 1 of an exterior wall
openings in such exterior wall
or required to be protected.
Section 5207 (a) 7.
be installed
located where
are prohibited
Projections, including eaYes, shall be one-
hour fire-resistive construction, heavy timber
or of noncombustible material if they project
into the 31 setback area from the property
line. Section 1710.
Show location of permanently wired smoke
detector, centrally located in corridor or
area giving access to sleeping rooms or above
stair if sleeping rooms are on upper level.
Section 1210.
A smoke detector shall be installed in the
basement of dwelling units having a stairway
which opens from the basement into the
dwelling. Such detector shall be connected to
a sounding device or other detector to p,rovide
an alarm which will be audible in the sleeping
area. Section 1210.
When the valuation of a room addition or
repair exceeds $1,000, or when sleeping rooms
are created, smoke detectors shall be provided
at existing bedrooms per item 16 above.
2
~ SIZES. LIGIIT. Vl!IITILAnON A11D GIAZillG
3
Habitable rooms, other than kitchens, shall
contain at least 70 square feet of floor area.
At least one room shall have not less than 120
square feet of floor area.
Section 1207 (b).
Window area must be at least 1/10 of the floor
area and a m1.n1.IDUID of 10 square feet per
S'akti9n l,'.(15 (a) . ..J:,ppea,;s to be defic_ient ¥,)-
t::.. I! , ~ +1 :::<i !::,___e.OI cC!C? I-?? • ex 1 <; ,
71 L; v. £ Jr/ , ? . c-;.,-, """ 1. ~ ,_,,, o, ·1-1.f',.,,
\ _ 'I'-J;::. ,f 7 7 I
/~ Openable Y.-in1dow area in habitable rooms ·must be ·, .. !J 1/20 of the floor area and a minimum of 5
G)
21.
square feet. In bathrooms, laundry rooms and
similar rooms 1/20 of area is required and
minimum is 1.5 sq. ft. (Section 1205 (a)).
At least 1/2 of the cotmaon wall must be open
and have an opening not less than 25 sq. ft.
nor one tenth of the floor area of the interior
room if light and ventilation is being supplied
from an adjacent room. Section 1205 (a).
Required windows shall not open into a roofed
porch unless the ceiling height is at least 7
feet, the longer side is at least 65% open, and
the porch abuts a street, yard or court.
Section 1205 (a).
Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required openable
windows are not provided. Section 1205 (a).
No habitable room,
be less than 7 1 011
1207 (c).
other than a kitchen, shall
in any dimension. Section
Show that ceiling height for habitable rooms is
a minimum of 7 1 611 • Section 1207 (a).
Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a minimum
of 7'0". Section 1207 (a).
Dimension on the plans the 3011 clear width for
water closet compartments and 24" clearance in
front of water closet. Section 511 (a).
Specify safety glazing for glazing in hazardous
locations such as glass doors, glazing adjacent
to such doors and glazing adjacent to walking
surfaces. Section 5406.
5/10/89
G
34·_
36.
Glazing, in the same wall plane as a door,
must be safety glazing if within 1211 of the
door and less than 6011 above the walking
surface, unless the glazing is leaded or
faceted glass. Section 5406 (d) 6.
Glazing in shower and tub enclosures shall be
tempered, laminated or approved plastic
(including windows within 5 feet of tub or
shower floor). Section 5406 (d) 5.
Sleeping rooms shall have a window or exterior
door for emergency exit. Sill height shall
not exceed 4411 above the floor. The window
Tm1St have an openable area of at least 5.7
square feet with the minimum openable width
2011 and the mipimum openaQle1 hfe,ight 2411 • j ;. ,-c
Section 1204. ~ l,,,_,r-u &; ~-,; 05..-;i?, C0"'/7 ' .... .>'
A mezzanine is an intermediate floor and may
not have a floor area exceedL~g 33 1/3 percent
of the total floor area in the room below.
The mezzanine floor must have a clear height
of 7 feet, above and below, and must have the
long side open to the room below except for
posts and protective walls or railings not
exceeding 4211 in height. Section 1716.
The loft you show does not comply as a
mezzanine floor and is, by Uniform Building
Code definition, a story. Section 1716.
EXITS. S'IAIRWAYS. AIID RAILINGS
Floors above the second story shall have not
less than 2 exits. Occupied roofs may have
one exit if such occupied areas are less than
500 square feet a.~d located no higher than
immediately above the second story. Section
3303 (a).
Required exit doorways shall be not less than
36" in width and not less than 6 1811 in height,
and shall be capable of opening at least 90
degrees. Section 3304 (e).
~ Provide ~ high protective railing for ~ porches, balconies, and open sides of stair
landings. Openings between railing shall be
less than~ Section 1711.
C!!) Show how guardrail connection
adequate to support 20 pounds per
at a right angle to the top rail.
details are
lineal foot
Iable.23-B.
3
Provide stairway
3306 (b) & (c).
and landing details. Section
a.
b.
c.
Maximum rise is 711 and minimum run is 1111 •
When the stairs serves less than 10
occupants, or serves an \.Uloccupied roof,
rise may be 811 maxi.mum and run 911 mini.mum.
Minimum headroom is 6 1 611 •
Minimum width is 36".
All handrails per Section 3306
~isfy the following:
(j), shall
a. Provide handrail for stairways
more risers.
with 4 or
b. Handrail shall be 3011 to 3411 abov·e the
nosing of treads.
c. The handgrip portion of handrail shall be
not less than 1 1/ 411 nor more than 211 in
cross-sectional dimension.
Every stain.·ay landing shall have a dimension,
measured in the direction of travel, at least
equal to the stairway width. Such dimension
need not exceed 36 inches. Section 3306 (g),
3304 (i).
A door may open inward at the top step of a
stairway provided the top step is not more than
7 1/211 lower than the floor level. Section
3304 (h).
Provide details of winding stairway complying
with Section 3306 (d):
a. Minimum tread is 6 inches at any point and
minl.JDUID 9 inches at a point 12 inches from
where the treads are narrowest.
b. Maximum rise is 8 inches.
c. Minimum width is 36 inches.
Provide spiral stairway details, per Section
3306 (f):
a. Mini.mum run is 7 1/2 inches measured at a
point 12 inches from where the treads are
the narrowest.
b.
c.
Maximum rise is 9 1/2 inches. Maximum
clear opening between risers is 6 inches.
Minimum headroom is 6 feet 6 inches
d. The tread must provide a clear walking
area measuring at least 26 inches from the
outer edge of the supporting colUIIlll to the
inner edge of the handrail.
Spiral stairways may not be used for required
exits when the area served is greater than 400
sq. ft. Section 3306 (f).
47. Provide I.C.B.O. Research Report and number
for metal stairway, or submit plans and
calculations and approved fabricator
registered with the building department or
note that the stairway fabrication plans shall
be submitted to and approved by the building
official prior to installation.
48.
49'.
In buildings over 2 stories in height, provide
3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within
10 feet horizontally of an exterior stain,•ay.
An exit balcony with 2 separated stairways is
exempt. Section 3306 (1).
Openings in exterior walls below or within 10
feet, measured horizontally, of an exterior
stair shall be protected by self-closing fire
assemblies having a three-fourths-hour fire
protection rating when the stair serves a
floor level having openings in two or more
floors below it. An exit balcony with two
separated stairways is exempt.
Section 3306 (1).
Exterior stairways shall not project into the
3 foot setback from the property lines.
Section 3306 (n).
The walls and soffits of the enclosed usable
space under interior stairs shall be protected
on the enclosed side as required for one-hour
fire-resistive construction. Section 3306
(m).
s2:" Within units, show that
minimum width of 36 inches.
corridors have a
Section 3305 (b).
ROOFING
Specify roof slope.
Roof slope
specified.
is not adequate for roof type
Table 32-B; Section 3203 (h).
Specify roof material
Chapter 32.
and application.
Specify I.C.B.0. or U.L. approval number for
roof materials not covered in U.B.C., e.g.,
tile, etc. Section 107.
5/10 89 4
The maximum slope for a fire retardant built-
up roof, with rock or gravel surfacing, is 3
inches in 12 inches. Section 3203 (e) 2.
The minimum slope for a fire retardant built-
up roof, with cap sheet surfacing, is 1/2 inch
in 12 inches. Section 3203 (e) 3,
Specify minimum 1/4 inch per foot roof slope
for drainage or design to support accumulated
water. Section 3207 (a), Section 2305 (£) and
Section 2511 (d) 6.
6✓ Show roof drains and overflows. Section 3207.
6f.
/ 62.
/ . 63.
J.. ,,
67.
68. I
/ 69.
Provide skylight
with Sections 3401
approval number.
details to show compliance
and 5207 or provide I.C.B.O.
Plastic skylights must be separated from each
other by at least 4 feet. Section 5207 (a) 6.
Show attic ventilation. Minimum vent area is
1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least 3
feet above eave vents or cornice vents. Show
required area and are.a provided.
Section 3205 (c).
MASONRY
Provide fireplace
construction to
standard drawing.
construction details or note
be per attached fireplace
Chapter 37.
Show anchored veneer support and connections
attached to wood in Seismic Zones 3 and 4,
comply with Section 3006 (d)l and Section 2515
(a). Show ties and #9 wire in horizontal
joints.
Show height
masonry walls.
and construction
Chapter 24.
details of all
Note that cleanout openings shall be provided
at the bottom of all cells to be grout filled
in accordance with Table 24-G. Cleanouts shall
be sealed before grouting, after inspection.
Show floor and roof connections to masonry
walls. Connection shall resist 200 pounds per
line.al foot or the actual design load,
whichever is greater. , Cross grain tension or
bending in wood ledgers is not permitted.
Section 2310 & 2312 (j)3A.
Provide details for
foundation walls, below
usable space exists on the
walls. Section 1707 (d).
to->1
damp proofing the
finish grade, where
interior side of the
5/10/89
Show a m1n111JUID 211 air space and flashing
between planter and building walls.
Section 2516 (c) 7.
GIJU,GK AND CIJU'ORTS
71. Garage requires one-hour fire protection on
the garage side of walls and ceiling common to
the dwelling. Table 5-B, Section 503 (d).
72. All elements supporting floor above garage,
including walls supporting floor joists, must
have one-hour fire-resistive protection on the
garage side. Section 503 (b)
73. Show 1 3/811 solid core self-closing door for
openings between garage and dwelling. Section
503 (d).
74.
75 .
76.
/78.
/ so.
Garages are not permitted to open into a room
used for sleeping purposes. Section 1104.
An occupancy separation is not required
between carport and residence, provided the
carport is open on two or more sides and has
no enclosed uses above.
Section 503 (a) Exception 3.
Show garage framing sections, size of header
over garage opening, lateral cross bracing at
plate line, method bracing garage front and
holddowns if required. Chapter 23.
NOTE: Maximum shear panel ratio is 3 1/2 to 1
for height-to-width. Table 25-I.
Doors may open into the garage only if the
flnor or landing in t.he garage is not more
than one inch lower than the door threshold.
Section 3304 (h).
Provide an 1811 raised platform for any FAU,
water heater, or other device in the garage
which may generate a flame or spark. UMC
Section 508, UPC Section 1310 (a).
FOOIIDATIOII REOOIJm400S
Per soils report, note on the plan the soils
classification, whether or not the ~oil is
expansive and note the allowable bearing
value. Section 2905 (c).
The foundation plan does not comply wit.h the
soils report recommendations for this project.
Please review the report and modify design,
notes and details as required to show compliance: ________________ _
5
y
82.
84.
85.
87.
96.
Provide notes on the foundation plan listing
the soils report recommendation for
foundations, slab and building pad preparation.
Provide a letter from the soils engineer
confirming that the foundation plan, grading
plan and specifications have been reviewed and
that it has been determined that the
recommendations in the soils report are
properly incorporated into the constniction
documents (when required by the soil report).
The soils report recommendations excavations be
reviewed by soils engineer. Note on the
foundation plan that 11Prior to the contractor
requesting a Building Department foundation
inspection, the soils engineer shall advise the
building official in writing that:
1.
2.
3.
The building pad was prepared in
accordance with the soils report,
The utility trenches have been properly
backfilled and compacted, and
The foundation excavations,
reinforcements comply with
report and approved plan.11
farmings and
the soils
Show height of all
23.
foundation walls. Chapter
Show height of retained earth on all foundation
walls. Chapter 23.
If cut or fill
foundation to
show steepness
Chapter 29.
slopes exist, show distance of
edge of cut or fill slopes and
and heights of cuts and fills.
Note on plans that
above finish grade.
wood shall be 611 minimum
Section 2907 (a).
Note on plans that surface water will drain
away from building and show drainage pattern
and key elevations. Section 2905 (f).
For buildings adjacent to slopes steeper than
3:1, the top of any exterior foundation shall
extend above the elevation of the street gutter
at point of discharge or the inlet of an
approved drainage device a minimum of 12 inches
plus 2 percent.
Dimension foundation per U.B.C. Table 29A:
Floors Footing
SUB;B:Orted* Stemwall Width Depth
1 6" 1211 1211
2 8" 1511 1811
3 1011 1811 2411
~·:Foundations may support a roof in
floors. Where only a roof is
foundation for one floor.
5/10/89
Thickness
6"
7"
8"
addition to the
supported, use
/14.
Show foundation sills to be pressure treated,
or equal. Section 2516 (c) 3.
Show foundation bolt size and spacing.
Section 2907 (f).
Specify size, I.C.B.O. number and manufacturer
of power driven pins. Show edge and end
distances and spacing.
Section 302 (c).
If required, show size, imbedment and location
of hold down anchors on foundation plan.
Section 2312 (f), 302 (c).
If hold downs are required, note on plan that
hold down anchors must be tied in place prior
to foundation inspection. Section 305 (e) 1.
96·. Show adequate footings under all bearing walls
and shear walls. Section 2907 (b).
97. Show on the plans stepped footings for slopes
steeper than 1:10, Section 2907 (c).
/
99.
Show minimum 1811
bottom of floor
clearance to bottom
Section 2516 (c) 2.
Show pier size,
undisturbed soil.
clearance from grade
joists and minimum
of girders.
spacing and
Table 29-A.
depth
to
1211
into
/-100. Show minimum underfloor access of 181' x 2411 •
Section 2516 (c).
/ 101. Show minimum underfloor ventilation equal to 1
sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners
as practicable and shall provide cross
ventilation on at least two approximately
opposite sides. Section 2516 (c) 6.
1'2.
/
Specify that
be pressure
Section 2516
posts embedded in concrete shall
treated per \JBC Std. No. 25-12.
(c) 1.
FRAIIIllG
Show wall bracing. Every exterior wood stud
wall and main cross-stud partition sl;iall be
braced at each end at least every 25 feet of
length with 1 x 4 diagonal let-in braces or
equivalent. Section 2517 (g) 3.
' ,/104. In 2-story buildings, shear panels at the
first story (at least 48 inches in width)
shall be located at each end or as near
thereto as possible and comprise at least 25
percent of the linear length of the wall, or
provide design. Section 2517(g)3.
6
1oi;..{ Note cross bridging or blocking. Floor joists
./" and rafters 1211 or more in depth shall be
supported laterally by bridging at intervals
not exceeding 8 feet, unless both edges are
held inline. Sec. 2506 (h), 2517 (d) 6.
Show blocking at ends and at supports of floor
joists, rafters and trusses at exterior walls.
Section 2517 (d) 3, 2517 (h) 6.
Show double joists. Floor joists shall be
doubled under bearing partitions running
parallel with the joists. Section 2517 (d) 5.
108. Bearing partitions, perpendicular to joists,
shall not be offset from supporting girders,
beams, walls or partitions, more than the depth
of the joist. Section 2517 (d) 5,
J.W.
Lr6.
Show rafter ties.
not more than 4
above the ceiling
ceiling joists are
(h) 4.
Rafter ties shall be spaced
feet on center and be just
joists, where rafters and
not parallel. Section 2517
Show rafter purlin braces to be not less than
45 degrees to the horizontal.
Section 2517 (h) 5.
;i.fl. Show double top plate with minimum 48" lap
splice. Section 2517 (g) 2.
112. Show nailing will be in compliance with Table
25-Q.
1.ri. Show or note fire stops at the follmdng
/ locations per Section 2516 (f):
a. In concealed spaces
partitions, including
the ceiling and floor
foot intervals along
wall;
of stud walls and
furred spaces, at
levels and at 10
the length of the
b. at all interconnections between concealed
vertical and horizontal spaces such as
occur at soffits, drop ceilings and cove
ceilings;
c.
d.
5/10/89
In concealed spaces between stair
stringers at the top and bottom of the run
and between studs along and inline with
the run of stairs if the walls under the
stairs are Wlfinished; and
in openings around vents, pipes, ducts,
chimneys, fireplaces and similar openings
which afford a passage for fire at ceiling
and floor levels, with noncombustible
materials.
/ 114. Show stud size and spacing. Maximum allowable
116.
stud heights: Bearing wall: 2 x4 and 2 x 6
max. 101 ; Non-bearing: 2 x 4 max. 141, 2 x 6
max. 20 1 • Table 25-R-3.
Studs supporting
ceiling must be 3
Table 25-R-3.
two
X 4
floors,
or 2 x 6
a roof and
at 16" o.c.
Note on A.I.T.C. Certificate
glued laminated wood members
the building inspector prior
Section 306 (f).
of Compliance for
shall be given to
to installation.
117. Detail all post-to-beam
connections and reference
plan, Section 2516 (m).
and post-to-footing
the detail to the
118. Detail shear transfer connections, including
roof and floor diaphragms, to shear walls.
Section 2513.
(~~9)specify nail size and spacing for
. __ ,..., walls, floor and roof diaphragms.
required blocking. Maintain maximum
all shear
Indicate
diaphragm
J, Kand dimension ratios. [Tables 25 I,
Section 4713 (d)].
12.G. Show 311 x 411 or 211 x 611 studs in first story
of three story building. Table 25-R-3.
,
121. Provide truss details and truss calculations
for this project. Specify truss
identification numbers on the plans.
122. Show 1/211 minimum clearance between top plate
of interior partitions and bottom chord of
tnisses. (To ensure loading will be as
designed).
12·( Provide roof framing plan and floor framing
' plan. Section 302 (c).
~ Provide framing sections through
Section 302 (c).
Specify all header sizes for opening over 41
wide. Section 2517 (g) 5.
Provide calculations for main vertical and
horizontal framing members and post footings.
Section 302 (b).
7
1271. Provide calculations
panels, shear transfer
302 (b).
for lateral loads, shear
and related. Section
no.
Show on the plans
developed in the
Section 302 (c).
end.)
all structural requirements
structural calculations.
(See comments below or at
Columns and posts located on concrete or
masonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be supported
by concrete piers or metal pedestals projecting
above floors unless approved· ·wood of natural
resistance to decay or treated wood is used.
Section 2516 (c) 4.
Individual concrete or masonry piers shall
project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood is used.
Section 2516 (c) 4.
Show location of attic access with minimum size
2211 x 3011 • Section 3205,
1;{. Show draft separation for attic areas between
units in a duplex. Section 2516 (f).
Specify plywood thickness, grade
identification index. Table 25-N.
and panel
When roof pitch is less than 3:12, design ridge
as a beam. Section 2517 (h),
135. If foundation cripple wall studs are less than
/ 1411 high, framing shall be solid blocking.
Section 2517 (g) 4.
13/ Cripple wall studs exceeding 4 feet in height
/ shall be 3 inch by 4 inch or 2 inches by 6
inches when supporting 2 stories.
Section 2517 (g) 4.
Show plywood sheathing over exposed eaves, or
other weather exposed areas, is "bonded with
exterior glue.11 Plywood used for exterior wall
covering shall be the exterior type. Section
2516 (i), 2516(g)3.
Detail truss layout for 3011 x 30" attic access,
if required for equipment in the attic.
Ridges, hips,
size larger
2517 (h) 3.
and valleys shall be at least one
than supported rafters. Section
In open beam construction, provide strap ties
across the beams at the ridge support. Section
2501 (b).
5/10/89
IIECIAIIICAL (URU'ORII HECIAIIICAL CODE)
All heating, ventilating, and cooling systems and
appliances shall comply with the Uniform Mechanical
Code.
~how the size, location and type of all
~eating and cooling appliances or systems.
Show source of combustion air to furnace, per
Chapter 6, UMC.
Every dwelling unit shall be provided with
-heating facilities capable of maintaining a
room temperature of 70 degrees F. at 3 feet
above the floor in all habitable rooms. Show
basis for compliance. UBC, Sec. 1211.
Show minimu.m 3011 deep unobstructed working
space in front of furnace. Section 505, UMC.
145. Note on plans, 11clearances
manufacturer's listing." Section
to be per
504, UMC.
+46. Furnace shall not be installed in any bedroom,
/ bathroom or in a closet or confined space with
access only through such room unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance.
Section 704 UMC.
Show I.C.B.O.
fireplace.
approval number for prefab
Show access to the attic or underfloor furnace
to be minimum 30 inches by 30 inches.
Section 708 & 709 UMC.
Note that passageway
shall be unobstructed
solid flooring not less
Section 708 UMC.
to the attic furnace
and have continuous
than 24 inches wide.
1so/1show permanent electrical outlet and lighting 7· fixture controlled by a switch for the attic
furnace. Section 708 UMC.
Show details
furnace under
roof or outside
to comply with
the floor, or
furnace.
Section 709 for
Section 710 for
Note on plan: Gas vents and non-combustible
piping, in walls, passing through three floors
or less shall be effectively draft stopped at
each floor or ceiling.
UBC, Section 1706 (a) 6.
/,J.53. Provide dryer vent to
, 1903.
outside. UMC, Section
8
KLECTRICAL (JIATIORAL KLEC'IRICAL COOK)
All wiring shall comply with the National Electrical
Code.
Show on the plan the amperage of the electrical
service, the location of the service panel and
.the location of any sub-panels. If service is
over 200 amps, submit single line diagram,
panel schedule and load calculations. y Show location of all electrical receptacles.
1_?6. Electrical receptacle locations and/or spacing ,, is not adequate in. _____________ _
1s/ Show at least one convenience outlet other than r. outlets for laW1dry, etc., outdoors, in garages
and basements. NEC, t. 210-52.
G Note c nvenience tlets
count..,;>-ta;~.,)," within
sink, outdoors and in
( other or laW1.dry
shall be GFI protected.
Note electrical system
per NEC, Art. 250-81.
in bathrooms, kitchen
6 feet of the kitchen
garages and basements
and similar equipment)
NEC, Art, 210-8.
ground to be provided
PLlMBillG (llllIFORM PUIHBillG COOK)
Jh'O· Show water heater size, type and location on
plans. UPC, Section 1301.
Show source for providing combustion air to
fuel burning water heater. If wall openings in
an enclosure are used, at least one-half of the
'required opening area shall extend into the
upper twelve inches of the enclosure and one-
half within the lower twelve inches. UPC,
Section 1307.
Fuel combustion water
installed in bath or
opening into bath or
1309,
heater shall not be
bedroom or in a closet
bedroom. UPC, Section
}63. Provide adequate barrier
heater from vehicle damage.
to protect water
UPC, Section 1310.
Show T and P valve on water heater
route of discharge line to exterior.
UPC, Section 1007 (e).
and show
165. Note on the plan that hose bibbs and lawn
/ sprinkler system shall have approved back.flow
prevention devices. UPC, Section 1003(h) &
(i).
5/10/89
/n.
Show shower stall can accommodate a 3011 circle
and has a mini.mum floor area of 1,024 sq. in.
UPC 909 (d).
!EISK DISUUJIOR (IJOPLKXES)
Show details of duplex common (party) walls
and floor/ceiling assemblies to achieve a
Sound Transmission Class (SIC) rating in walls
of SO decibels and an Impact Insulation Class
(IIC) rating on floor/ceiling of 50 decibels.
Title 25.
Show how penetrations of assemblies for
piping, electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 25.
Provide insulation in walls and ceiling to
achieve SIC of 50 between garage and living
area if garage use is not controlled by
resident. Title 25.
ENERGY CONSERV AJ'IOR
Permit applications received after June 30,
1988, are regulated by th.e new Residential
Energy Standards. Provide plans, calculations
and worksheets to show compliance.
The new regulations require a properly
completed and properly signed Fom CF-lR to be
either imprinted on the plans, taped to the
plans or 11sticky backed11 on the plans, to
allow the building inspector to readily
co:--.tJpare: the actual construction with. the
requirements of the approved energy design.
Section 1403(a)l, Title 24, states that Form
CF-lR shall be signed by the person
responsible for its preparation. The signer
shall be a civil engineer, mechanical
engineer, electrical engineer, architect,
general building contractor, mechanical
contractor, or electrical contractor licensed
or registered to practice by the State of
california or other individual eligible under
Division 3 of the Business and Professions
Code to sign such documents. Document signers
are subject to the limitations in Division 3
of the Business and Professions Code. Please
provide the signature. ·
All energy items shown on the plans must be in
agreement with the information shown on the
properly completed Form CF-lR.
9
-
Specify on the building plans all of the
mandatory energy conservation requirements as
listed on the enclosure titled, 11Mandatory
Energy Conservation Requirements".
1vs'. Show the make, model and
/ space heating (or cooling)
heat loss calculations if
45,000 BTU/Hr.
efficiency of the
system and provide
the output exceeds
aFor room additions, show that tbe glazing area V of the addition does not exceed 16% of the
newly-conditioned floor area, plus glazing
removed or relocated due to the addition.
Provide fluorescent general. lighting
kitchen(s) per CAC, Title 24, 2-5352(J).
in
Please see additional corrections, or remarks,
on the following page.
Thank you.
5/10/89 10
Date, 0 -Jl-89 Jurisdiction C'e-11..s lJ
VALUATION AND PLAN CHECK FEE
o Bldg, Dept,
O Esgil
PLAN CHECK NO ,._8'-9"'--_9"'--'--/"""c;,.'--
BU ILDlNG ADDRESS _..;c?-__ 7'----"2-=--'2.__=----'S,=-=o'----"'C...c....-=cOV¼)_· ..;;_;:.,;,.e __ C=!Q_..._ ____ _
APPLICANT/CONTACT _________ PHONE NO. _______ _
BUILDING OCCUPANCY rfl -S DESIGNER PHONE _____ _
TYPE OF CONSTRUCTION U rJ CONTRACTOR PHONE -----
BUILDING PORTION BUILDING AREA VALUATION VALUE
' MULTIPLIER
cSFO 11 VA _,. ~b-0 c;, C, ..s-e:,,;oo
/
• ,1..,. 1t I<, / '"}, .5V I,~ a I
.
Air Conditioning
Commercial @ .,
Residential (<l
Res. or Comm.
Fire Snrinklers @
Total Value ~ l 4-"CJI '/
Building Permit fee$ !89, bV r '-/, 5'°)<. !::>"'"'R $ ~ .=:,-0, .s--v
Plan Che ck f ••-$<---------------------'$'-'-f}__--'-~-J'-,_8_
3 __
COM MEN TS,._:----------------------------
-z 3<f-2-.y SHEET OF -~ --12/87
"' ... ro 0
C!l
"O "' J "' > "' 0::
"' ... ro
0
C!l
"O "' J "' > "' 0::
~□
"' ... ro 0
C!l
"O "' J "' > "' 0::
□
□ □ □
~□
0 □
cf □
0D 0D
~ ~ ~~
□
□
□
□
□
□
□
□
D
□
□
□
ENGINEERING CHECKLIST
Date: __ ..=G'--'-47::..::..:.::..._""8'!..,___ _____ _
LEGEND
ri7
@
I tern Complete
Plan Check No. _8f""-'-""0--'-9,'--1/-'-?, ____ _
Project Address: .27.22 &com, M.
Project Name: Ro~t=4 Aoo nae>
Item Incomplete -Needi
Your Action
Field Check Date: ==-'------------1 , 2, 3 Number in circle
indicates planchec~ B : number that deficiency
was identified
LEGAL REQUIREMENTS
Site Plan
1. Provide a fully dimensioned site plan drawn to scale. Show: North
arrow, property lines, easements, existing and proposed
structures, streets, existing street improvements, right-of-way
width and dimensioned setbacks.
2. Show on Site Plan: Finish floor elevations, elevations of finish
grade adjacent to building, existing topographical lines, existing
and proposed slopes, driveway and percent (%) grade and drainage
patterns.
3. Provide legal description of property.
4. Provide assessor's parcel number.
PERMITS REQUIRED
Grading
5.
6.
7.
8.
9.
Grading permit required. (Separate submittal to Engineering
Department required for Grading Permit).
Grading plans in plan check PE _____ _
Need the following completed prior to building permit issuance:
A. Grading plans signed.
B. Grading permit issued.
C. Grading completed.
D. Certification letter and compaction reports submitted.
E. Grading inspected and permit signed off by City Inspector.
Right-of-Way Permit required for work in public
(e.g., driveway approach, sidewalk, connection to
etc).
right-of-way
water main,
Industrial Waste Permit application required. To be filled out
completely and returned to Development Processing.
•
□
D
□
□
□
□
□
FEES REQUIRED
10. Park-in-Lieu fees required.
Quadrant=-~---' Fee Per Unit: __ ~ ___ , Total Fee:_--:._--:_-__
11. Traffic impact fee required. b I "-~~~~ Fee Per Unit:_===-• Total Fee: ,._._,~_:....-F
12. Bridge and Thoroughfare fee required. ,, I, t?W~!
Fee Per Unit: _____ , Total Fee: _?1.0~c,J!.J)JL~=-..c.....::...tr'
13. Public facilities fee required.
14. Facilities management fee required. Fee: ,nok
'.! () 1 5 • Addi tiona I EDU' s required : --,,:21-eJnR'"""'"""'-=~=-ff<-""J/,._ ___ .,,...._
Sewer connection fee: -Sevil!r permit no.
1 6. Sewer la tera I required : --~--'-:.....c...;:_--=i-d""-------
R EMA R KS: ____________________________ _
O.K. to issr:=2::S:~ ... Date:
If you have any questions about any of the above items identified on this plan
check, please call the Development Processing Department at 438-1161.
t ,....,
\,)
"' ....
"' 0
co
"Cl "' 3' "' > "' c::
"' ....
"' 0
co
"Cl "' 3' .!!! > "' c::
"' ....
"' 0
co
"Cl "' 3'
"' > "' c::
u u u c.. c.. c..
? l o ~ Y'-1 , ....
If --:)O'-' Y'--ovJL
Co.. \ I Y'A..IL, C,\-t
PLANNING CHECKLIST
Plan Check No. ~ff0-9 / Ip Address 2."72-2. Sococ..(.,o Ln.
Type of Project and Use
Zone __ 'P-'---'C=------Use Allowed? YES _:j,.__
Rear !5 Setback: Front 2.0 Side 7' It:,"
2 1 Zone 112~ Facilities Management t,_ :l-0.-le
School District: Encinitas
NO
San Dieguito __
Carlsbad San Marcos L
Discretionary Action Required
Environmental Required
Landscape Plan Required
Comments
Coastal Permit Required
YES
YES
YES
NO _l
NO;i,_
NOX-_
YES NO_)(_
Type __
Additional Comments ------------------------
91 F'l pj f Q'yY)
{'7\t,,n::µA,,Q 0,a a:e:::r,...~---_________________ _
OK TO ISSUE _________ _ DATE ---------
CERTIFICATION OF COMPLIANCE
CITY OF CARLSBAD Plan Check No.
DEVELOPMENT PROCESSING SERVICES DIVISION
2075 LAS PALMAS CARLSBAD, CA 92009
(619) 438-1161
This form shall be used to determine the amount of school fees for a project and to verify
that the project applicant has complied with the school fee requirements. No building
permits for the projects shall be issued until the certification is signed by the
appropriate school district and returned to the City of Carlsbad Building Department.
SCHOOL DISTRICT:
__ Carlsbad Unified
6350 Yarrow Drive Ste. A
Carlsbad, CA 92009 (438-5710)
San Marcos Unified
270 West San Marcos
San Marcos, CA 92069
Blvd.
(744-4776)
Encinitas Union Elementary San Dieguito Union High School
189 Union Street 710 Encinitas Boulevard
Encinitas, CA 92024 (944-4306) Encinitas, CA 92024 (753-6491)
Project Applicant: _,A._--'-c=~-=-vv_e.-,_L_L--______ APN: '!ILL-.sr.z -~ z
Project Address: _d_"1_~_.;z_~_-'c-"o-'-~.:::.IC-'-o=--c:...=:.c.~_M;____:C-~ _________ f
RESIDENTIAL: SQ. FT. of living area Rsa Number of dwelling units
SQ. FT. of covered area -----SQ. FT. of garage area
COMMERCIAL/
Prepared By
INDU~Q-~
Date
FEE CERTIFICATION
(To be completed by the School District)
Applicant has complied with fee requirement under Gqv,ernment Code 53080
Project is subject to an existing fee agreement
Project is exempt from Government Code 53080
---
Residential
Comm/Indust
I
Final Map approval and construction started before
(other school fees paid)
Other
Fee Levied: $ I 3,,z t; .. c,-c, based on y _.;,-,) sq.
Fee Levied: $ based on sq. J ' a /
ft.@ /, ,----~ j
ft.@
AB 2926 and SB 201 fees are capped at $1.53 per square foot for residential.
AB 2926 is capped at $.25 per square foot for commercial/industrial.
1986.