Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout6148 GATEWAY RD; ; FPC2018-0236; Permit(7city of
Carlsbad
Print Date: 10/19/2021 Permit No: FPC2018-0236
Job Address: 6148 GATEWAY RD, CARLSBAD, CA Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class: Underground Fire
Parcel #: Track #: Applied: 07/30/2018
Valuation: $0.00 Lot #: Issued:
Occupancy Group: Project #: DEV12023 Finaled Close Out: 07/29/2021
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #: Inspector:
Plan Check #: Final Inspection:
Project Title: UPTOWN BRESSI RANCH
Description: UPTOWN BRESSI - UNDERGROUND BLDG #8
Applicant: FPContractor:
CAL-WEST FIRE PROTECTION SPECIALIST CAL-WEST FIRE PROTECTION
GONZALO PENA 8361 COMMONWEALTH AVE
8361 COMMONWEALTH AVE BUENA PARK, CA 90621-2525
BUENA PARK, CA 90621-2525 (714) 912-4552
(714) 912-4552
FEE AMOUNT
FIRE Underground Piping with up to 4 Hyds/Risers $625.00
Total Fees: $625.00 Total Payments To Date: $625.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
- . Fire Protection by Computer Design
Cal-West Fire Protection
1113 N Gates St.
Santa Ana, Ca. 92703
866-374-9378
Job Name Uptown Bressi "Bldg. #8'
Building
Location El Fuerte St. & Gateway Rd.
System
Contract : 18-099
Data File : Bldg. - 8.WXF
Computer Programs by Hydratec Inc. Revision: 50.52.1
Water Supply Curve C
Cal-West Fire Protection Page
Uptown Bressi 'Bldg. #8" Date 7.19.18
City Water Supply: Demand:
Cl - Static Pressure : 100 Dl - Elevation : 1.516
C2 - Residual Pressure: 20 D2 - System Flow : 500
C2 - Residual Flow : 2500 D2 - System Pressure : 17.837
Hose ( Demand)
D3 - System Demand : 500
Safety Margin : 78.090
150
140
130
p120
R°
E10° ---_
9 S0
80
U 70
R 60
E 50
40
30
C2
20
: :zY 2_____
--
30O"600 900 1200 1500 1800 2100 2400 2700
FLOW( N A 1.85)
Computer Programs by Hydratec Inc. Revision: 50.52.1
Fittings Used Summary
Cal-West Fire Protection Page 2
Uptown Bressi "Bldg. #8" Date 7.19.18
Fitting Legend
Abbrev. Name 1/2 % 1 14 1% 2 2'/z 3 31/2 4 5 6 8 10 12 14 16 18 20 24
E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61
F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28
G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13
I NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121
Zif Febco 876V Fitting generates a Fixed Loss Based on Flow
Units Summary
Diameter Units Inches
Length Units Feet
Flow Units US Gallons per Minute
Pressure Units Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with *• The fittings marked with a * show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a * will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Revision: 50.52.1
-Pressure I Flow Summary - STANDARD
Cal-West Fire Protection Page 3
Uptown Bressi "Bldg. #8" Date 7.19.18
Node Elevation K-Fact Pt Pn Flow Density Area Press
No. Actual Actual Req.
BOR 0.5 0.0 na 500.0
UG1 -3.0 2.89 na
UG2 -3.0 5.3 na
UG3 -3.0 13.89 na
SRC -3.0 17.84 na
The maximum velocity is 12.15 and it occurs in the pipe between nodes UG2 and UG3
Computer Programs by Hydratec Inc. Revision: 50.52.1
Final Calculations - Hazen-Williams
Cal-West Fire Protection Page 4
Uptown Bressi "Bldg. #8 Date 7.19.18
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftngs Pe Pv ******* Notes
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
BOR 500.00 4.26 E 13.167 12.000 0.0 Qa = 500.00
to 120.0 0.0 13.167 1.516
UG1 500.0 0.0545 0.0 25.167 1.372 Vel = 11.25
UG1 0.0 4.23 2F 15.379 30.000 2.888
to 150.0 E 19.223 34.603 0.0
UG2 500.0 0.0373 0.0 64.603 2.412 Vel= 11.42
UG2 0.0 4.1 3E 49.537 10.000 5.300
to 150.0 Zif 0.0 49.537 6.000 * * Fixed Loss = 6
UG3 500.0 0.0435 0.0 59.537 2.588 Vel = 12.15
UG3 0.0 4.23 2E 38.446 25.000 13.888
to 150.0 G 3.845 80.736 0.0
SRC 500.0 0.0373 T 38.446 105.736 3.949 Vel= 11.42
0.0
500.00 17.837 K Factor = 118.39
Computer Programs by Hydratec Inc. Revision: 50.52.1
A-2102 Wafer Check Valve
4, 6', 8' 175 psi (1207 kPa) Working Pressure
350 psi (2413 kPa) Test Pressure
Listed by Underwriters Laboratories, Inc. and Approved by Factory
Mutual Research Corporation.
PARTS LIST
Catalog
Parts Description Number Material Material Standard
CW-1 Seat Ring Cast Bronze ASTM B584
CW-2 Body Cast Iron ASTM A126
CW-3 0-Ring (2 reqd) Buna-N ASTM D2000
CW-4 Clapper Cast Bronze ASTM B584
CW-5 Bushing (2 req'd) Brass ASTM B16
CW-6 Spring Stainless Steel Type 302
CW-7 Hinge Pin Stainless Steel Type 303
CW-8 Seal, Seat EP Rubber ASTM D2000
FBH
WAFER CHECK VALVE WEIGHTS
4 6 8
Lb 15.75 22.50 36.50
Kg 7.14 10.21 16.56
C-1 WAFER CHECK VALVES Rev. 2-03
[Mueller Cø.1
UL /FM
FIRE PROTECTION PRODUCTS
CW-2
CW-1
CW-
DIMENSIONAL INFORMATION FOR WAFER CHECK VALVES
Size DIMENSIONS
A
In. (mm)
B
In. (mm)
C
In. (mm)
D
In. (mm)
E
In. (mm)
4 3.75 (95) 1.34 (34) 6.88 (175) 3.00 (76) 4.03 (102)
6 3.75 (95) 1.53 (39) 8.75 (222) 4.56 (116) 6.06 (154)
8 4.25 (108) 1 1.92 (49) 1 11.00 (279) 1 6.00 (152) 1 7.98 (203)
WAFER CHECK VALVE ORDERING INFORMATION
Specify: Quantity, Size and Catalog Number.
WAFER CHECK VALVE PARTS ORDERING INFORMATION
Specify: Quantity, Catalog Number, Part Name, Size of Valve,
Catalog Number of Valve and Year Date of Valve.
Page C-i -6
No. 135
CARLSBAD FIRE DEPARTMENT
Fire Prevention Division
1635 Faraday Avenue - Carlsbad, CA 92008
760.602.4665
WATER AVAILABILITY FORM
SECTION A: TO BE COMPLETED BY CUSTOMER
PROJECT NAME: Sprouts Farmers Market SR#:
PROJECT ADDRESS: 6217 El Fuerte St
(Assigned upon plan submittal)
CITY: Carlsbad
PHONE: (714) 914-4552 (Cal-West Fire) FAX NUMBER: ( 714 ) 912-4641
Largest Building (ft.2): 26,000 Sprinkled? Yes Construction Type: LINK
SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD.
Water Purveyor: City of Carlsbad
Location of test (reference map required): El Fuerte St north of Gateway Rd
TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED
Flow Test Results
Static pressure: 129 PSI Hydrant Number (if applicable):H20910
Elevation of test: 402 Feet Main Size: 24 INCH
Pressure Zone 700 Feet Date/Time of Test
Pitot Tube Reading PSI Corresponding Flow: GPM
Total Flow: 8.000 GPM Residual Pressure 110 PSI
At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm.
Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer
modeling), fill out the information above as applicable and check here:
Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606
Signature:_________________________________________
Title/or gä' jectManager Date: 01/11/2018
P4O
3O
I I
N + Legend
4 w_Hydrant
Pipe
ZONE
8' -550
- 700 $
$
Fire Flow Test
Location H20910 L
F7
GATEWAYRD 12- 12
7WY!L*RTINGT
flN
-
H ALAMEDA CR ANCO
-o r
—L OWN GARDEN RD
-SI-
14
-a
4
Sprouts Farmers Market - Fire Flow Analysis
MJ Accessories
ANSI/AWWA C111/A21.11
BA I
II
,J.iJIp.Is 'IwIp
NOM. O.D.A B C I.D.B.C.
OLT BOLT WT
SIZE ' HOLE QTY (LBS.)
2 6.12 0.62 1.18 3.40 2.61 4.75 00.75 2 1
3 769 137 484 406 619 0075 4 S 062
4 9.12 0.75 1.50 5.92 4.90 7.50 00.88 4 6
6 11.12 0,88 1,63 8.02 7.00 9.50 00.88 6 10
8 13.37 1.00 1.75 10.17 9.15 11.75 00.88 6 14
10 15.62 1.00 1.75 12.22 11.20 14.00 00.88 8 20
12 17.88 1.00 1.75 14.32 13.30 16.25 00.88 8 24
14 20.25 1.25 2.00 16.40 15.44 18.75 00.88 10 45
16 22.50 1.31 2.06 18.50 17.54 21.00 00.88 12 55
18 24.75 1.38 2.13 20.60 19.64 23.25 00,88 12 55
20 27.00 1.44 2.19 22.70 21.74 25.50 00.88 14 66
24 3150 156 231 2690 2594 3000 0088 16 90
20 30 39.12 2.00 2.75 33.29 32.17 36.88 01.13 220
36 4600 200 275 3959 3847 4375 0113 24 286
42 53.12 2.00
1-2.00
2.75 45.79 44.67 50.62 01.38 28 288
48 60.00 2.75 52.09 50.97 57.50 01.38 32 400
O.D.
B.C.
f-i f1 IA
C
Page 15
REGISTERED TRADEMARK OF STAR PIPE PRODUCTS
STAR PIPE PRODUCTS
HOUSTON CORPORATE TOLL FREE I'SoO'999'3I9 FAXISI'SSS'SREE
JMagIe Building essentials
for a better tomorrow
*1111
l-
:1:111
SUBMITTAL AND DATA SHEET
of cFOF
PIPE SIZE
(IN)
AVERAGE O.D.
(IN)
NOM. I.D.
(IN)
MIN. T.
(IN)
MIN. E
(IN)
APPROX. D9
(IN)
APPROX. WEIGHT
(LBS/FT)
PRESSURE CLASS 165 psi (DR 25)
4 4.80 4.39 0.192 5.25 5.57 1.9
6 6.90 6.31 0.276 6.40 8.00 3.9
8 9.05 8.28 0.362 7.05 10.50 6.7
10 11.10 10.16 0.444 8.20 12.88 10.1
12 13.20 12.08 0.528 8.80 15.31 14.4
PRESSURE CLASS 235 psi (DR 18)*
4 4.80 4.23 0.267 5.25 5.87 2.6
6 6.90 6.09 0.383 6.40 8.43 5.3
8 9.05 7.98 0.503 7.05 11.06 9.2
10 11.10 9.79 0.617 8.20 13.57 13.9
12 13.20 11.65 0.733 8.80 16.13 19.7
PRESSURE CLASS 305 psi (DR 14)*
4 4.80 4.07 0.343 5.25 6.17 3.2
6 6.90 5.86 0.493 6.40 8.87 6.7
8 9.05 7.68 0.646 7.05 11.63 11.6
10 11.10 9.42 0.793 8.20 14.27 17.6
12 13.20 11.20 0.943 8.80 16.97 25.1
Consult JIM Eagle" for CSA and other listing availability prior to shipment.
Note: *FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14.
* Contact your JIM eagleTM sales representative for location availability.
D9 1
14
O.D. 01 E
I.D. Inside Dameter
O.D. : Outside Diameter
T. Wall Thickness
D° Bell Outside Diameter
E: Distance between Assembly Mark to
the end of spigot.
Assembly Mark
Product Standard: ANSI/AWWA 0900
Pipe Compound: ASTM D1784 Cells Class 12454
Gasket: ASTM F477
Integral Bell Joint: ASTM D3139
Certifications: ANSI/NSF Standard 61
UL Standard 1285
Pipe Length: 20 feet laying length
Installation: AWWA 0605
JIM Eagle" Installation Guide
JM Eagle1M also manufactures this pipe in green for sewer force main applications
and purple, specifically for reclaimed water systems. This pipe is made to the same
requirements as our standard products. The only difference is that the pigment
used is green or purple. These products will not be marked with UL or NSF listing
marks. Additionally, the green pipe will be marked 'Forced Sewer" and the purple
pipe will be marked: "Reclaimed Water... Do Not Drink."
For Non-Health Hazard Applications
Job Name Contractor
Job Location Approval
Engineer Contractor's P.O. No.
Approval Representative
MasterSeries®
LF876V
Double Check Detector Backflow
Prevention Assemblies (Type II)
Size: 21/2" - 8" (65mm - 200mm)
The FEBCO MasterSeries LF876V Double Check Detector
Assembly is specifically designed to protect against possible
backpressure and backsiphonage conditions for non-health
hazard (i.e., pollutant) application in accordance with Local
Governing Water Utility Code.
This Backflow Assembly is primarily used on potable drinking
water systems and fire sprinkler systems, where Local Governing
Code mandates protection from non-potable quality water being
pumped or siphoned back into the potable water system.
Features
Main Valve:
Inline Serviceable Assembly
Horizontal "N-Pattern" Installations
Vertical-Up "Z-Pattern" Installations
No Special Tools Required for Servicing
Captured Modular Spring Assembly
Reversible & Replaceable Discs
Field Replaceable Seats
Ductile Iron Valve Body Design
Stainless Steel Check Components
Winterization feature with disc retainers and valve body drain ports
Clapper Check Assembly
Commonality between 1st & 2nd Check Components
Captured 0-ring Design
Auxiliary Bypass:
Compact Bypass Design; Remains within Main Valve Assembly
Profile
Inline Serviceable 3/4" Back-flow Assembly
No Special Tools Required for Servicing
Field Replaceable Seats & Discs
Detect Potential Underground Water Leaks
Detect Unauthorized Water Usage
Model LF876V Double Check Detector Assembly
Specifications
The FEBCO MasterSeries LF876V Double Check Detector Valve
Assembly shall be installed on the potable water supply and at
each point of cross-connection to protect against possible
backpressure and backsiphonage conditions for non-heafth hazard
(i.e., pollutant) applications. The assembly shall consist of a
main line valve body composed of two (2) independently acting
approved clapper style check modules with replaceable seats
and disc rubbers. Servicing of both check modules does not
require any special tools and are accessed through independent
top entry covers. This assembly shall be fitted with approved UL/
FM inlet/outlet resilient seated shutoff valves and contain four (4)
properly located resilient seated test cocks as specified by AWrNA
Standard C510. The auxiliary bypass line contains a 5/u"x1/4 ' Water
Meter that complies with ANSI/AW\NA Standard 0700 coupled
with an approved check assembly. The bypass line is designed
to detect leaks or unauthorized water usage of the water system
while protecting against possible backpressure and backsiphonage
conditions for non-health hazard (i.e., pollutant) application. The
assembly shall be approved for horizontal and/or vertical-up
installations while meeting the requirements of A\MNA Standard
C51 0 flow and pressure loss performance parameters.
NOTICE
The information contained herein is not intended to replace the
full product installation and safety information available or the
experience of a trained product installer. You are required to
thoroughly read all installation instructions and product safety
information before beginning the installation of this product.
jT(gJfDj
Inquire with governing authorities for local installation requirements
"The wetted surface of this product contacted by consumable
water contains less than 0.25% of lead by weight.
FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
WAY-5 -, ff
please contact FEBCO Technical Service FEBCO reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequently sold. A WATTS Brand
Options - Suffix
OSY: ULJFM Approved OS&Y Gate Valves [ANSI/A\MNA
C515 Compliant]
CFM: Totalizing Cubic feet/mm 5/ex 3/4"Water Meter [ANSI!
A\MNA 0700 Compliant]
GPM: Totalizing Gallons/mm %x 3/4" Water Meter [ANSI!
A'MNA 0700 Compliant]
LG: Less Shutoff valves; This is NOT an APPROVED
ASSEMBLY
Example Ordering Description:
4' LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff
Valves & Gallons per Minute Water Meter
4" LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff
Valves & Cubic Feet per Minute Water
Meter
Available Components
Wye Strainer: FDA Approved [ASME B16.1 Class 125 &
A'MNA Class D Range]
Series 611 Valve Setter MJ x MJ - Mechanical Joint x Mechanical
Joint [A'MNAC111/A21.11]
MJ x FL - Mechanical Joint x Range
[A\MNA C1 1/A21.11; ASME B16.1 Class
125/A\MNA Class D Range]
FL x FL - Flange x Flange
[ASME 1316.1 Class 125 & AVWVA Class
D Range]
Materials
Below is a genera] materials list of the Model LF876V PJI assemblies
size 2112" through 8" is similar in materials and construction.
Please contact your local FEBCO Representative if you require
further information.
Main Valve Body: Ductile iron Grade 65-45-12
Coating: Fusion epoxy coated intema] and external
AWrNA 0550-90
Shutoff Valves: OSY resilient wedge gate valve AWWA C515
(IJLJFM)
Check Seats: Stainless Steel
Disc Holder: Stainless Steel
Elastomer Disc: Silicone
Spring: Stainless Steel
Clamp: AWWA C606
Approvals - Standards:
Approved by the Foundation for Cross-Connection Control
and Hydraulic Research at The University of Southern
California [FCCCHR-USC]
ASSE 1048 Listed
""UL Classified [US & Canada]
**FM Approved
IAPMO/cUPC
AWNA Standard C510 Compliant
End Connections: Compliant to ASME 816.1 Class 125 &
A\MNA Class D Range
**Assembly configured with UL'FM Approved OS&Y RW Gate
Valves. Less gate valve assemblies are not ULJFM approved
configurations.
Assembly Flow Orientation:
Horizontal (N-Pattern 21/2" - 8") - Approved by FCCCHR-USC,
ASSE, cULus, FM, IAPMO/cUPC
Vertical Up (Z-Pattern 21/2" - 8') - Approved by FCCCHR-USC,
ASSE, cULus, FM, IAPMO/cUPC
® eFM
Approved C ®US
1048 B64.5
Pressure - Temperature
Max. Working Pressure: 175p5i (12.1 bar)
Min. Working Pressure: lOpsi (0.7 bar)
Hydrostatic Test Pressure: 350psi (24.1 bar)
Hydrostatic Safety Pressure: 700p5i (48.3 bar)
Temperature Range: 33°F - 140°F [0.5°C- 60°C]
Continuous
Dimensions - Weights
Size: 21/211 - 811
Below are the nominal dimensions and physical weights for the Model LF876V size 21/2 through 8. Allowances must be made for normal manufacturing tolerances.
Please visit our website to download a copy of this product's installation instructions, or contact your local FEB00 Representative for more
information.
Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern)
Note: The Series LF876V is shipped in the standard (N-Pattern)
orientation as shown above.
Gate Valve
Side View
Clearance
LF876V
SZE(DN OMENSIONS WEIGHT**
in. mm
A
in. mm
B
in. mm in.
C
mm
0
in. mm
E
in. mm
F
in. mm in.
6
mm
H
in. mm in. mm
IJ
in. mm in. mm
L
in. mm
OSY
lbs. kg.
21/2 65 291A 740 121/2 318 61/4 159 25Y4 642 171/2 445 135A 346 271/4 692 51/2 140 111/8 283 31/2 89 16% 416 11112 292 216 98
3 80 291/8 740 121/2 318 61/4 159 253/4 654 17Y4 451 141/8 359 281/4 718 51/2 140 111A 283 33/4 95 221/4 565 111/2 292 242 110
4 100 311/8 791 14 356 7 178 27Y4 705 18Y4 476 151/2 394 31 787 6 152 111/8 283 41h 114 231/4 591 13 330 347 157
6 150 353/4 908 16 406 8 203 32Y4 831 221/a 562 185A 473 371/4 946 71/4 184 121/2 316 51/2 140 301/8 765 13 330 529 240
8 200 4Q3/ 1035 18½ 470 9¼ 235 363/4 933 25½ 638 20~ 527 41½ 1054 8½ 216 14 356 6~ 172 37~ 959 141/2 368 827 375
Notes:
* Indicates nominal dimensions with OSY Gate Valves (Full Open Position)
Indicates weight of complete Backflow Assemblies with specified Gate Valves
6" LF876V
poi Service Flow Rated Flow IJL Rated Flow
18
16
1
4
2
10
us B 8
6
0 200 400 600 800 1000 1200 1400 1600 gpm
757 2,271 3785 5300 1pm
7.5 11.4 17.0 fps
8" LF876V psi Service flow Rated Flow UL Rated Flow
is
16
14
12
DC 10
V5 U B
0 400 800 1200 1600 2000 2400 gpm
1514 3028 4543 6057 7571 9085 1pm
7.5 10.5 15.3 fps
Performance
How capacity chart identifies valve performance based upon
rated water Velocity up to 20fps
Maximum service flow rate is determined by maximum rated
Velocity of 7.5fps.
AWINA Manual M-22 (Appendix C) recommends that the
maximum water Velocity in the serces be not more than 1 Ofps.
UL flow rate is determined by typically rated Vocity of 15 feet/sec.
Capacity N-Pattern
2½" LF876V psi Service Flow Rated Flow *UL Rated Flow
22 20
18 r I
10
16 I
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350gpm
284 568 852 1136 1pm
7.5 14.7 fl fps
3" LF876V psi Service flow Rated Flow *UL Rated Flow
22 20
18
16
14
I H - - - - - -HT
0 50 100 150 200 250 300 350 480 450 500 gpm
379 757 1136 1514 1pm
7.5 14.5 22.0 fps
4" LF876V
psi Service Flow Rated Flow UL Rated Flow
J_ 18
16 I -I -
14 -1-
J_
B
12
DC
10
8
". 6 - - -- - - J
4 I I -
2
o I
0 100
379
200 300
1136
7.5
400 500 600
1893
12.8
700 800gpm
2650 1pm
19.1 fps
Pipe Support
(furnished by customer)
for valve weight only.
Vertical Orientation Z-Pattern"
Flow curve z
Standard Orientation "N-Pattern"
Flow curve N
M -
A WT1S Brand
ES-F-LF876V 1515
USA: Tel: (800) 767-1234 • Fax: (800) 788-4491 • FEBcoonhine.com
Canada: Tel: (905) 332.4090 • Fax: (905) 332.7068 • FEBcoonline.ca
Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEBcOonline.com
0 2017 FEBCO
ES-A-In Building Riser
Series IBR A
AMES
In-Building Risers FIRE
Sizes: 4" - 10" (100— 250mm) =
TEST CA'
OOW INCLUDED'
Features
Cost savings
Corrosion resistant stainless steel
construction, type 304
Ease of installation and light weight
allows one person to position and
handle the riser
Minimal site preparation; joint restraint
one-piece construction reduces time
and labor; no missing parts, no leaks;
easily identifiable for approvals
Includes Test Cap and Coupler
UL/FM approved
Sizes: available in 4" - 10"
(100-250mm) with various
lengths to meet all local requirements
Designed to meet NFPA 24-2007
Section 10.6.5
AWWA C900 Inlet/DIP
AWWA C606 Outlet
Job Name
Job Location
Engineer
Approval
Series IBR In-Building Risers are used to connect the main fire supply to
the building overhead fire system. The fitting passes under the foundation
without joints and extends up through the floor. Provided with installation
tabs, the unit has a CIPS (Cast Iron Pipe Size) coupler for easy connec-
tion to the underground supply (AWWA C900 PVC and Ductile Iron Pipe)
and industry standard grooved-end connection (AWWA C606) on the
building side for easy connection to the overhead fire sprinkler system.
Ames In-Building Risers are precision engineered and manufactured to
provide exceptional reliability and reduce installation time & labor costs
associated with field assembly. In accordance with NFPA 24-2007, the
UL/FM approved In-Building Risers replace numerous fittings, elbows
& spools and reduces the possibility of leaks or failure in comparison to
traditional installation methods and materials. Factory tested integrity
ensures the highest quality installation. The use of stainless steel signifi-
cantly increases the reliability and life of the riser.
*The wetted surface of this product contacted by
consumable water contains less than one quarter
of one percent (0.25%) of lead by weight.
Contractor
Approval
Contractor's P.O. No.
Representative
Ames product specifications in U.S. customary unto and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right
to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or
subsequently sold.
www.amesfirewater.com
Specifications
In-Building Riser shall be installed as indicated on the
plans. Riser shall be composed of a single extended
90 degree fitting of fabricated 304 stainless steel tub-
ing, maximum working pressure 200psi (14 bar). The
fitting shall have a grooved-end connection on the
outlet (building) side and a CIPS coupler on the inlet
(underground) side. The grooved end shall include a
coupler and cap to facilitate testing of the underground
piping. The In-Building Riser shall be an Ames Fire &
Waterworks Series IBR.
Approvals
Fittings FM class 1920
UL HKQA (4-10)
Us L
Dimensions - Weights
A
Grooved End
f
;7:1-•----. (Flange Optional)
-I--
CIPS Coupling
Tie-Rod Bracket
C
in. mm
A(OD)
in. mm ft.
B
cm
C
ft cm Ms. kg
4 100 4½ 114 6 183 6 183 71 32
6 150 65/8 168 6 183 6 183 98 44
8 200 8% 219 6 183 6 183 129 59
10 250 103/4 273 6 183 6 183 202 92
Consult factory for custom leg dimensions.
Standards
NFPA - Designed to allow the contractor to conform
to NFPA 24-2007 Section 10.6.5:
Where a riser is close to building foundations, under-
ground fittings of proper design and type shall be used to
avoid pipe joints being located under the foundations.
NFPA 24-2007, 10.1.1, 10.6.7
End Connections
Horizontal End: Mates with Ductile Iron Pipe and
AWWA C900 Pipe (PVC Pipe with Ductile Iron Pipe
Equivalent OD's)
Utilizes Gasket conforming to UL 157 with "Lock in"
gasket configuration
1t4(ilii
in. mm in.
4 100
M1Ii
72307
4.8
6 150 6.9
8 200 9.1
10 250 11.1 282
Vertical End:
Meets AWWA C-606 dimensions for roll grooved pipe
Meets AWWA C-207 class D for flanges
Ratings
Meets AWWA C-900 pressure class 200, DR 14 Pipe
Testing
Welds are 100% leak tested at the factory
SIZE-
in. mm
DESIGN PROOF
psi bar
4 100 1000 70
6 150 1000 70
8 200 800 56
in 250 800 58
IMPORTANT: Inquire with governing authorities for
local installation requirements.
fflk
A M E S
FIRE&WATERWORKS www.amesfirewater.com
A Watts Water Technologies Company USA: Backflow- 1427 N. Market Blvd • Suite #9 • Sacramento, CA 95834 • T: 916-928-0123 • F: 916-928-9333
Control Valves- 18550 Hansen Road • Houston, TX 77075 • T: 713-943-0688 • F: 713-944-9445
Canada: 5435 North Service Rd. • Burlington, ONT. L7L 5H7. T: 905-332-4090 • F: 905-332-7068
ES-A-In BuildingRiser 0935 © 2009 Ames Fire & Waterworks
PACIFIC STATES PSCIPCO
CAST IRON PIPE COMPANY DIVISION OF MWANE, INC.
P.O. BOX 1219, PROVO, UTAH 84603
TELEPHONE (AREA CODE 801) 373-6910
STANDARDS
In each of the following, standards are developed by committees consisting of consumer,
general interest and manufacturing members:
American National Standards Institute (ANSI)
American Water Works Association (AWWA)
American Society for Testing and Materials (ASTM)
Underwriters Laboratories (UL) MH16433(N)
National Fire Protection Association (NFPA)
National Sanitation Foundation (NSF) 61-1989
Factory Mutual (FM) J 12V0A8 .AH
For ready reference, standards for ductile iron pipe are listed below:
Standard Designation
ANSI/AWWA C1501A21.50
ANSJIAWWA C151/A21.51
ANSI/AWWA C11O/A21.1O
ANSI/AWWA Cl 53/A2 1.53
ANSI/AWWA C111/A21.11
ANSI/AWWA C115/A21.15
ANSI/AWWA Cl 0121.4
ANSI/AWWA C105/A21.5
& ASTM A674
ANSI/AWWA C600
ASTM A746
NFPA Outside Protection 24
Sublect Covered
Design
Water Pipe
Fittings - Cast Iron
Fittings - Ductile Iron
Rubber - Gasket Joints
Flanged Pipe
Cement - Mortar Linings
Polyethylene Encasement for Ductile Iron Pipe
Installation
Gravity Sewers
Fire Protection Piping
Pacific States ductile iron pipe meets and exceeds the requirements of all of the above
national standards relating to pipe manufacture and performance.
PACIFIC STATES
CAST IRON PIPE COMPANY
DIVISION OF McWANE, INC.
P.O. BOX 1219, PROVO, UTAH 84603
TELEPHONE (AREA CODE 801) 373-6910
FAX: (801) 377-0338
EMAIL: sales@pscipco.com
WEBSITE: www.pscipco.com
~ r-A4, ~!'
Thickness, Dimensions and Weights of Mechanical Joint Ductile Iron Pipe by Size for Each Thickness.
Nominal
Wt. of
Barrel
Mechanical Joint
Wt. of Wt. Per Avg. Wt.
Thickness Thickness OD* Per Ft. t Bell Lgth.t Per Ft.
Size Class In. In. Lb. Lb. Lb. Lb.
3 53 .31 3.96 10.90 11 230 11.4
4 53 .32 4.80 13.80 16 290 14.6
6 53 .34 6.90 21.40 18 405 22.4
8 53 .36 9.05 30.10 24 565 31.4
10 53 .38 11.10 39.20 31 735 40.9
12 53 .40 13.20 49.20 37 925 51.3
tincluding bell; calculated weight of pipe rounded off to the nearest 51b *Tolerances of OD of spigot end; 3-12 in. ±0.06 in.
*Including bell; average weight per foot, based on calculated weight of
pipe before rounding.
Visit our website at www.kennedyvalve.com K KENNEDY VALVE
A DIVISION OF MCWANE, INC I ASSOCIATED WITH AWWA, NSF AND IJLFM
0-509 FULL BODY CAS T IRON
RESILIENT WEDGE VA1VE
..........
I!IT.Irc1:II"
A
During the decade of the 1980's, the waterworks industry was introduced to the Resilient
Seated Gate Valve, a design principle that is dominant in preference for use in distribution
systems. Kennedy Company was at the forefront in this industry-wide movement by
introducing the Ken Seal Series, our AWWA C509 Resilient Seated Gate Valve.
In 2002, with the end user in mind, Kennedy redesigned the Ken Seal Series introducing the
model KS-FW. The goal of the redesign was to eliminate the customer need for any anti-
rotational bolts. Kennedy did this by designing a machined elliptical bolthole in place of an
as-cast opening. This elliptical design allows valve installers to slide a standard sized bolt into
the slot, therefore eliminating the need to have two different types of bolts on the installation.
RECOMMENDED SPECIFICATIONS FOR C-509 CAST IRON
RESILIENT WEDGE GATE VALVES
KENNEDY VALVE COMPANY
Valves shall conform to the latest revision of AWWA Standard C-509 covering resilient
seated gate valves for all water supply service.
The valves shall have a cast iron body, bonnet, and 0-ring plate. The wedge shall be totally
encapsulated with rubber.
The sealing rubber shall be permanently bonded to the wedge per ASIM D429.
Valves shall be supplied with 0-ring seals at all pressure retaining joints. No flat gaskets
shall be allowed. Blind bolts shall not be allowed.
The valves shall be either non-rising stem or rising stem, opening by turning left or right, and
provided with 2" square operating nut or a handwheel with the word "Open" and an arrow
to indicate the direction to open.
Stems for NRS assemblies shall be cast bronze with integral collars in full compliance with
AWWA. OS&Y (rising stems) shall be bronze. All stems shall operate with bronze stem nuts
independent of wedge and of stem (in NRS valves). Stainless stems are available but not
standard. NRS stems shall have two 0-rings located above thrust collar and one 0-ring
below. Stem 0-rings shall be replaceable with valve fully opened and subjected to full
pressure. The NRS stems on 2"- 12" shall also have two low torque thrust bearings located
above and below the stem collar to reduce friction during operation.
Waterway shall be smooth, unobstructed and free of all pockets, cavities and depressions
in the seat area. Tapping valves 4" and larger shall accept a full size tapping cutter.
The body, bonnet, and 0-ring plate shall be fusion-bond epoxy coated, both interior and
exterior on body and bonnet. Epoxy coating shall be NSF 61 certified and applied in accor-
dance with AWWA C550.
Each valve shall have manufacturers name, pressure rating, and year in which it was manu-
factured cast in the body. Prior to shipment from the factory, each valve shall be tested by
hydrostatic pressure equal to the requirements of AWWA C-509 (and UL/FM where applicable).
Valves shall have all component parts cast and assembled in the USA and shall be
manufactured by the Kennedy Valve Company.
(Revised 03-27-2011)
Jti'I(4I'T.T. I II it j
DELRIN THRUST BEARINGS ABOVE
AND BELOW THE THRUST COLLAR
REDUCE FRICTION AND MINIMIZE
OPERATING TORQUES
LONG, TROUBLE FREE LIFE WITH
HIGH STRENGTH, NON-CORRO-
SIVE BRONZE STEM AND STEM
NUT.
ALL NRS STYLE VALVES ARE STAIN-
LESS
THE OPERATING MECHANISM IS TRIPLE
0-RING SEALED TO COMPLETELY SEAL
AGAINST LEAKAGE PAST THE STEM. TWO
0-RINGS ARE PROVIDED ABOVE THE
THRUST COLLAR AND ONE BELOW.
UPPER 0-RINGS CAN BE REPLACED
UNDER PRESSURE WITHOUT REMOVING
THE STEM WHEN THE VALVE IS FULLY
OPENED.
0-RING SEALS AT STUFFING BOX
AND BONNET TO BODY FLANGES
TO ENSURE THE BEST POSSIBLE
SEAL. NO FLAT GASKETS.
100% EPDM COATED
WEDGE WITH TWIN SEAL
DESIGN ENSURES BUBBLE-
TIGHT SEAL UP TO 250 PSI
EVERY TIME.
ELLIPTICAL BOLT
HOLE DESIGN
ELIMINATES THE
NEED FOR
ANTI-ROTATION
BOLTS
KENNEDY CORROSION
RESISTANT FUSION-
BONDED EPDXY COATING,
CONFORMING TO AWWA
C-550 AND NSF61
CERTIFIED, PROTECTS BOTH
INSIDE AND
OUTSIDE OF VALVE.
SMOOTH, UNOBSTRUCTED PADS ON THE BOTTOM OF
FULL SIZE WATERWAY IS ALL VALVES KEEP VALVE
FREE OF POCKETS, CAVI- IN UPRIGHT POSITION
TIES, AND DEPRESSIONS FOR EASIER STORAGE
ALLOWING FOR MINIMAL AND PROTECTION FROM
FLOW LOSS AND LOWER THE ELEMENTS.
PUMPING COSTS.
ALL TAPPING VALVES
ACCEPT FULL SIZE
TAPPING CUTTER.
ALL VALVES ARE RATED AT 250 PSI FOR
AWWA SERVICE AND 200 PSI FOR
ULFM SERVICE. ALL VALVES ARE
HYDROSTATICALLY TESTED TO 500 PSI.
10 YEAR LIMITED WARRANTY
(Revised 03-27-2011)
8571 8561 8057 8572
MECHANICAL JOINT ENDS FLANGED ENDS THREADED ENDS FLANGED X MJ
2°" 12° 2" 12° 2° 3 3°" 12"
Nil
A 4--~
8597 8576 8901 8701
POSH-ON FOR PVC MECHANICAL TYTON ENDS FLANGED ENDS
2" • 8" CUTTING-IN JOINT PUSH-ON FOR (DI. & 0900) POST INDICATOR VALVE (PIV)
4°" 12" 4°'12" 3' . 12" L I 0
8902 8950 8071 8068
FLANGED & TYTON JOINT TAPPING X MJ MECHANICAL JOINT FLANGED ENDS
PUSH-ON FOR (D.L & C900) TAPPING VALVE POST INDICATOR VALVE (PIV) OS&Y CONSTRUCTION
4" • 12" 4" • 12" 3" • 12" 2 1/2° • 12"
A B C D E G H P Q P S U V No of Tums
2 7 3 1/4 - 51/4 107/8 - - 3 - - 71/4 - - 43/4
2 1/2" 7 1/2 - 7 11 3/8 - - 31/4 163/8 13 7/8 71/4 - - 51/2
3 8 3 1/2 - 7 1/8 12 3/8 - 53/4 3 1/2 18 7/8 15 5/8 10 - - 10
4° 9 41/2 63/4 - 143/4 41/2 6 3/4 41/2 223/4 18 1/4 10 63/4 93/4 1 13 1/2
6 101/2 5 77/8 - 19 51/4 7 3/4 5 301/8 23 3/4 12 75/8 113/16 191/2
8" 111/2 51/2 81/2 - 22 1/2 55/8 8 1/2 51/2 373/4 29 1/4 14 8 1/2 113/4 251/2
10° 13 7 10 - 261/2 7 10 - 453/4 35 3/8 18 10 131/2 311/2
12" 14 63/4 111/4 - 30 81/2 10 7/8 - 531/8 405/8 18 11 143/4 373/4
KENNEDY VALVE
A DIVISION OF MCWANE, INC.
www.kennedrlalve.com
2007
1021 E. Water Street
Elmira, New York 14901
P.O. Box 981
Phone (607) 734-2211
Fax 1-607-734-3288
(Revised 03-27-2011)
MJ Accessories
ANSI/AWWA C111/A21.11
E
OD IA
l I I L
:jIt G
28' for sizes 3-24 in. 20 for sizes 30-60 in.
NOM. PIPE
SIZE O.D.
2 230
3 3.96
4 4.80
6 6.90
8 9.05
10 11.10
12 13.20
14 15.30
16 17.40
18 1930
20 21.60
24 25.80
30 32.00
36 38.30
42 4430
48 50.80
OD B P G
2.48 0.12 0.15 1.05
3.86 0.12 0.15 1.05
0.75 0.31 4.68 0.16
0.75 0.31 6.73 0.16
0.75 0.31 8.85 0.16
0.75 0.31 10.87 0.16
0.75 0.31 12.95 0.16
075 031 1499 016
0.75 0.31 17.07 0.16
0.75 0.31
0.31
0.31
19.13
21.20
25.34
0.16
0.16 0.75
0.75 0.16
1.00 0.38 31.47 0.16
1.00 0.38
0.38
37.67 -
43.78
0.16
0.16 1.00
1.00 038 49.98 0.16
0.62
0.62
0.62
0.62
0.62
0.62
0.62
0.62.
0.73
0.73
0.73
A B C
0.48 0.62 0.31
0.22 1.22
0.22 1.22
0.22 1.22
0.22
0.22 1.22
0.22 1.22
0.22 1.22
0.22 1.22
0.22 1.22
0.22 1.22
0.37 134
0.37 134
0.37 1.54
037
OD A
Bf
1F
TRANSITIONIIMECHANICAL-JOINT GASKET
NOM PIPE
I
A B C(REP) OD E F C
-
2 2.375 0.56 0.66 0.31 232 0.12 0.21 1.10
3 3.500 0.72 0.64 034 3.43 0.12 038 1,10
4 4.500 0.76 0.73 033 4.43 0.20 037 1.26
6 6.625 0.75 On 0.32 6.53 0.20 0.36 1.25
8 8.625 0.82 0.73 0.34 8.50 0.20 0.43 1.27
10 10.750 0.79 0.75 0.31 10.59 0.20 0.39 1.26
12 12.750 0.84 0.75 0.33 12.56 0.20 0.44 1.28
UCAT. 4 01
- REGISTERED TRADEMARK OF STAR PIPE PRODUCTS
STAR PIPE PP.ODUCTS
FM S HOUSTONCORPO}ATE TOLL FREE I.ROO-999.S9 FAX281.558.9RRO
Page 17
MJ Accessories
ANSI/AWWA C111/A21.11
1-Bolts, Double Ended Rods & Nuts
HSLA STEEL
SPECIFICATIONS:
Bolts & Nuts are manufactured in accordance with ANSI / AWWA C1 11 / A21.1 1.
Material is High Strength Low Alloy Steel per ANSI/AWWA Clii /A21.1 1.
Threads per ASME BL1 unified standard coarse (Class 2A & 2B(
MECHANICAL PROPERTIES
Yield Strength 45000 PSI (mm)
Elongation in 2in. 20% (mm)
BLUE BOLT/NUT/ROD
CHEMICAL PROPERTIES
Carbon 0.20% Max
Manganese 1.25% Max
Sulfur 0.05% Max
Nickel 0.25% Mm
Copper 0.20% Mm
Combined 1.25% Mm (Ni, Cu, Cr)
T-Bolts, Rods & Nuts have fluoropolymer coating material which is VOC-compliant, resin-bonded, thermally cured
and dry lubricant.
COATING PHYSICAL PROPERTIES
Film Thickness: 0.3 to 0.4 mil per coat
Number of Coats: 3 to 4 coats
Adhesion: 1 mm cross hatch test + 5 Pulls. Good knife resistance
Cure Test: 50+Rubs with MEK. No substrate exposure
Pencil Hardness: Pencil Hardness: 4-6H
Volatile Organic Compounds 2.741b5/gal
Stainless Steel 1-Bolts & Nuts
ALLOYS SS 304 & SS 316 PER ASTM F593
SPECIFICATIONS:
T-bolt dimensions are manufactured in accordance with ANSI / AWWA Cl 11 / A21.1 1.
T-bolt alloys SS 304 and SS 316 per ASTM F593
Heavy Hex Nut Alloys SS 304 & SS 316 per ASTM F594.
MECHANICAL PROPERTIES
Tensile Strength: 85,000 PSI to 140,000 PSI
Yield Strength: 45,000 PSI (mm)
COATING SPECIFICATION
Nuts have fluoropolymer coating material which is
VOC-Compliant, resin-bonded, thermally cured and dry lubricant.
COATING PHYSICAL PROPERTIES
Film Thickness: 0.3 to 0.4 mil per coat • Pencil Hardness: 4-6H
Number of Coats: 3 to 4 coats • Volatile Organic Compounds 2.74 lbs/gal
Adhesion: 1mm cross hatch test + 5 Tape Pulls. • Continous use temperature - 356°F
Cure Test: 50+ Rubs with MEK, no substrate exposure • Color: SS 304 is green, SS 316 is red
A.
AWWA
MEMBER
UCAT.I4EI
REGISTERED TRADEMARK OF STAR PIPE PRODUCTS
STARR PIPE PRODUCTS
HOUSTON CORPORATEITOLL FREE 1-5R999.3OO9 F4X2SI.S5S.9O
Page 18
iMECHANICAL JOINTI:IS]II(S1It,l31
PIPE SIZE
(IN)
BOLT SIZE RANGE' OF
(IN) TORQUE (FT-LBS)
2-3 5/8 45-60
4-24 3/4 75-90
30-36 1 100-120
42-48 11/4 120-150
'These torque ranges are requirements ofAWWA C600
Accessories
ANSI/AWWA C111/A21.11
1/8-in. Radius Maximm
012
C
D
Minimum 1i16-inx45Chamfer.
k__ -
-
ANN
-
T-HEAD (LOW ALLOY STEEL)I4Th ttfl
NOM A. B C I) THREADS F H R SIZE PER IN.
5/sx3 1.50 0.625 3.00 2.00 11 0.625 1.062 0.625 0.312
/ux3½ 130 0.625 3.50 2.70
2.50
11
10
0.625 1.062 0.625 0.312
1/4x3 Vz 1.75 0.750 3.50 0.750 1.250 0.750 0.375
1/4 x4 175 0750 400 300 10 070 12S0 0750 0.375
1.250 0.750 0.375 3/4x4½ - 1.75 0.750 4.50 3.00 - 10 0.750
Y4x5 1.75 0.750 5.00 3.00 10 0.750 1.250 0.750 0.375
1/4xS 1/s 1.75 0.750 5.50 3.70 10 0.750 1.250 0.750 0.375
1x5½ 2.25 1.000 5.50 3.00 8 1.000 1.625 1.000 0.500
1x6 2.25 1.000 6.00 3.00 8 1.000 1.625 1.000 0.500
15Ax6 230 - 1.250 6.00 3.00 7
7
7
1250
1.250
1250
2.000 1.250 0.625
0.625
0625
1 ¼x6 1/2 2.50 1.250
1.250
6.50
850
3.50
350
2.000
2000
1.250
1250 144x8½ 250
(Rd's WIN ~i I IBM Hl
P --
-
-.
- L
'
ANTI-ROTATION T-HEAD (LOW ALLOY STEEL) I I
B C
BOLT &
I
D
I NUT
E THREADS F
I
18
I I
R MOM.
I
A SIZE PER IN.
5/8 X3 1.50 0.625 3.00 2.00 0.63 11 0.625 1.062 0.625 0.312
150 0,625 350 230 063 11 0.625 1.062 0.625 0.312
3/4x3 ½ 1.75 0.750 3.50 2.50 0.63 10 0.750 1.250 0.750 0.375
~x4 1.75 0.750 4.00 0.63 10 0.750 1.250 0.750 0375
0.750 0.750 1.250 0.750 3/4X4½ 1.75 4.50
3.00--f
3.00 063 10 0.375
~x5 175 0750 500 300 063 10 0750 1250 0750 0375
Page 19
UCAT.I4.OI
REGISTERED TRADEMARK OF STAR PIPE PRODUCTS
STAR PIPE PRODUCTS HOUSTON CORPORATE TOLL FREE '-'°O-999sIU9 FAX lSI.SSS.9000
A!
--U
AA
JR. I A R T A
I
Mj x Mj ll %-mjxmj BENDS (%) BENDS (1/8)
R '' NOM. T 11 WT R WT WT
SIZE (LBS) (Los) (LBS) (LBS)
2 0.39 3.25 2.25 14 1.80 1.96 13 1.80 4.02 13 1.80 8.12 13
3 0.48 5.50 4.00 35 3,00 3.62 30 3.00 7.56 30 3.00 15.25 30
4 0.52 6.50 4.50 55 4.00 4.81 50 4.00 10.06 50 4.00 20.31 50
6 0.55 8.00 6.00 85 5.00 7.25 75 5.00 15.06 75 5.00 30.50 75
5.50 17.62 110 8 0.60 9.00 7.00 125 5.50 8.44 110 5.50 35.50 110
10 0.68 11.00 9.00 190 6.50 10.88 155 6.50 22.62 160 6.50 45.69 160
12 0.75 12.00 10.00 255 7.50 13.25 215 7.50 27.62 220 7.50 55.81 220
14 0.6 6 14.00 1130 340 7.50 12.06 270 7.50 25.12 275 7.50 50.75 275
16 0.70 15.00 1230 430 8.00 13.25 340 8.00 27.62 345 8.00 55.81 345
18 0.75 16.50 14.00 545 8.50 14.50 420 8.50 30.19 430 8.50 60.94 430
20 0.80 18.00 15.50 680 9.50 16.88 530 9.50 35.19 535 9.50 71.06 540
24 0.89 22.00 18.50 1025 11.00 18.12 755 11.00 37.69 765 11.00 76.12 -770-
30 1.03 25.00 21.50 1690 15.00 27.75 1380 15.00 57.81 1400 15.00 116.75 1410
36 uS 2800 2450 2475 1800 3500 2095 1800 7288 2135 1800 14725 2145
21.00 42 1.28 31.00 27.50 3410 42.25 2955 21.00 88.00 3020 21.00 177.69 3035
48 1.42 34.00 30.50 4595 24.00 49.50 4080 24.00 103.06 4170 24.00 208.12 4190
II
MJXPEBENDSJ
1
/PE 11 '/4- Mj x PE BENDS (1/4) BENDS BENDSC 16) BENDS (/32)
MOM. T A B R VT A
I WT B R WT B A Il A w'r B R SIZE (LBS) (LBS) (LBS) (LBS)
3 0.48 5.50 13.50 4.00 35 3.00 11.00 3.62 30 3.00 11.00 7.56 30 3.00 11.00 15.25 30
4 052 630 1450 450 50 400 1200 481 45 400 1200 1006 45 400 1200 20.31 45
6 0.55 8.00 16.00 6.00 80 5.00 13.00 7.25 70 5.00 13.00 15.06 70 5.00 13.00 30.50 70
8 0.60 9.00 17.00 7.00 120 5.50 13.50 8.44 lOS 5.50 13.50 17,62 105 5.50 13.50 35.50 105
0.68 10 11.00 19.00 9.00 190 6.50 14.50 10.88 155 6.50 14.50 22.62 160 6.50 14.50 45.69 160
12 075 1200 2000 1000 255 750 1550 1325 215 7.50 1550 2762 220 750 1550 5581 220
14 0.66 14.00 22.00 11.50 325 7.50 15.50 12.06 255 7.50 15.50 25.12 260 7.50 15.50 50.75 260
16 0.70 1500 23.00 12.50 410 8.00 16.00 13.25 320 8.00 16.00 27.62 325 8.00 16.00 55.81 325
24 0.89 22.00 30.00 18.50 985 11.00 19.00 18.12 715 11.00 19.00 37.69 725 11,00 19.00 76.12 730
30 1.03 25.00 33.00 21.50 1585 15.00 23.00 27.75 1275 15.00 23.00 57.8 1295 15.00 23.00 116.75 1305
36 1.15 28.00
11,
136.00 24.50 2310 18.00 26.00 35.00 1930 18.00 26.00 72.88 1970 18.00 26.00 147.25 1980
42 1.28 -ii-6(T I 39.00 27.50 3200 21.00 29.00 42.25 2745 21.00 1 29.00 88.00 2810 21.00 -2900-,'177.64 2825
UCAT.I4.OI
REGISTERED TRADEMARK OF STAR PIPE PRODUCTS
STAR PIPE PRODUCTS
HOUSTON CORPORATEITOLL FREE I.8RO.999.009 P4X 2SI.SSR.9S FMAçt
,pippdcH.om
Page 22
Plugs with Chains
1 Model No. Size Type
Ic] 6404 I 21/" I Brass I
Optional Finish:
0-B Polished
0-C Rough Chrome Plated
-D Polished Chrome Plated
Break Caps
I Model Size Type .
LO 6406 2'" Aluminum
LO 6407 1
/2
2" Plastic 1
Threads: Adjustable Plugs
0 NST __71111111111 __
0 Other 6408 I 21/" I Aluminum I
LEl 6409 Plastic
Contact factory for current listings and approvals
ff
B
=6't=~
L_
6337
QVLPh.
GUARDIAN
FIREEQUIPMENT,INC. DETAIL AND SUBMITTAL SHEET MIAMI, FL
00.327.6584• Fax 800.827.3869
6300 Series - Fire Dept. Inlet Connections - Bodies
Project/Location: Date:
Architect/Engineer: Qty:
Contractor:
EAppropriate Selection
Used as auxiliary connections through which the fire department can pump water
to supplement existing water supplies. Provides 250 GPM flow (minimum), per
21/2" inlet.
Two and three-way - inlet connections feature clappered brass bodies (straight
or angle pattern), with female hose thread swivel inlets and female outlets. Cast
brass construction, standard.
Model No.
Ii 6314*
Outlet
I Back
Two and Three-Way
Size
4" x 21/2" x 21/2"
Connections
Clappers
1
A
51/2"
B
I 81/8
El 6315* Angle 4" x 21/2' x 21/2" 1 81/8" 8/4"
6324 Back 4" x 21/2" x 21/2" 2 71/4" 101/2
0 6325 Angle 4" x 21/2" x 21/2" 2 81/4" 101/2"
E] 6326 Back 6" x 21/2" x 21/2" 2 71/4" 101/2'
E] 6327 Angle 6" x 21/2" x 21/2" 2 10" 101/2'
E] 6336 Back 6" x 21/2" X 21/2" x 21/2" 3 101/2" 13/4"
6337 Angle 6" x 21/2' x 21/2" x 21/2" 3 111/2 141/2"
Body Lettering
El AUTO SPKR 0 STANDPIPE
Blank (unlettered)
*Auto Spkr lettering only
Optional Finish: 0-B Polished Brass Threads:
0-C Rough Chrome Plated 0 NST
0 D Polished Chrome Plated 0 Other
Plugs with Chains and Break Caps - Used to keep fire dept. inlet connections free of debris and
protect female threads.