1966 OLIVENHAIN RD; ; FPC2019-0177; Permit
I1Il1iIs]I (7,ity of Carlsbad Print Date: 12/14/2020 Permit No: FPC2019-0177 Job Address: 1966 OLIVENHAIN RD, ENCINITAS, CA 92024-5676 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2550310300 Track #: Valuation: $1,167,147.57 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Fire Sprinklers Applied: 07/31/2019 Issued: 09/10/2019 DEV02001 Finaled Close Out: 08/17/2020 Inspector: Final Inspection: Project Title: OLIVENHAIN MUNICIPAL WATER DIST Description: OLIVENHAIN MWD -NEW SYSTEM WITH POC @ BASE OF RISE (646 HEADS) Applicant: FPContractor: HAMILTON FIRE PROTECTION INC HAMILTON FIRE PROTECTION INC MATT HAMILTON 25060 HANCOCK AVE, # STE 103 25060 HANCOCK AVE, # STE 103 MURRI ETA, CA 92562-5930 MURRIETA, CA 92562-5930 (951) 348-2068 FEE AMOUNT FIRE Hourly Services First Hour $159.00 FIRE NFPA 13 System > 100 heads (includes 1 riser) $858.00 Total Fees: $1,017.00 Total Payments To Date: $1,017.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov Hamilton Fire Protection 25060 Hancock #103 Murrieta CA 92562 951-834-6305 Job Name : OMWD AREA 1 Drawing Location : 1966 OLIVENHAIN RD ENCINITAS Remote Area Contract Data File : OMWD AREA I .WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 Hamilton Fire Protection Page OMWD AREA I Date 7/21/19 Hydraulic Design Information Sheet Name - OMWD AREA 1 Date - 7-21-19 Location - 1966 OLIVENHAIN RD ENCINITAS Building - System No. - Contractor - Contract No. - Calculated By - Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 7 FT Occupancy - UNUSED ATTIC SPACE S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E N Area of Sprinkler Operation - 1230 System Type Sprinkler/Nozzle Density - .1 (X) Wet Make TYCO D Area Per Sprinkler - 130 ( ) Dry Model TYFRB E Elevation at Highest Outlet - 10.875 ( ) Deluge Size 1/2 S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 478.16 Press Required - 89.6 BOR Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 5/30/19 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 140 8 Press - R Residual Press - 138 Elev. - Well Flow - 1630 Proof Flow S Elevation - 0 U P Location - 1966 OLIVENHAIN RD P L Source of Information - OMWD Y C Commodity Class Location O Storage Ht. Area Aisle W. N Storage Method: Solid Piled % Palletized % Rack N SR TA O C R K A G E Single Row ( ) Conven. Pallet Double Row ( ) Slave Pallet Mult. Row Flue Spacing Longitudinal 1ILJLSt¼J1LLQ.L L)at.LSCLO LLL)VSLACLL. Auto. Storage ( ) Encap. Solid Shelf ( ) Non Open Shelf Clearance:Storage to Ceiling Transverse Computer Programs by Hydratec Inc. Revision: 50.53.5 Water Supply Curve C Hamilton Fire Protection Page 2 OMWD AREA 1 Date 7/21/19 City Water Supply: Demand: Cl - Static Pressure : 103 Dl - Elevation : 4.710 C2 - Residual Pressure: 100 D2 - System Flow : 478.163 C2 - Residual Flow : 1630 D2 - System Pressure : 96.465 Hose( (Demand) : 100 D3 - System Demand :578.163 Safety Margin : 6.094 150 140 130 p120 R11° C11 C2 E 100 S 90 S80 - u 70 R6° E5° 40 30 20 10 ni 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N 11 1.85) Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Hamilton Fire Protection Page 3 OMWD AREA 1 Date 7/21/19 Fitting Legend Abbrev. Name % % 1 1% 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 1390 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13Gate Valve 0 0 0 0 0 1 1 1 I 2 2 3 4 5 6 7 8 10 11 13 L NFPA l3 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 139OFlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90' Ell Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 4.5 5.1 0 0 0 0 0 X 90Tee-BranchFirelock002 0 0 0 0 0 8.5 10.8 13 0 16 21 25 33 9.3 11 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Pressure / Flow Summary - STANDARD Hamilton Fire Protection Page 4 OMWD AREA 1 Date 7/21/19 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 1 10.875 5.6 7.0 na 14.82 0.1 130 7.0 2 10.875 5.6 7.51 na 15.35 0.1 130 7.0 3 10.875 5.6 9.42 na 17.19 0.1 130 7.0 4 10.875 5.6 10.6 na 18.23 0.1 130 7.0 5 10.875 5.6 11.78 na 19.22 0.1 130 7.0 6 10.875 5.6 13.35 na 20.46 0.1 130 7.0 7 10.875 5.6 15.8 na 22.26 0.1 130 7.0 8 10.292 26.93 na 9 13.292 5.6 8.15 na 15.99 0.1 130 7.0 10 13.292 5.6 8.74 na 16.56 0.1 130 7.0 11 13.292 5.6 10.94 na 18.52 0.1 130 7.0 12 13.292 5.6 12.29 na 19.64 0.1 130 7.0 13 13.292 5.6 14.78 na 21.53 0.1 130 7.0 14 13.292 5.6 16.69 na 22.88 0.1 130 7.0 15 10.292 27.86 na 16 10.875 5.6 9.1 na 16.89 0.1 130 7.0 17 10.875 5.6 9.75 na 17.48 0.1 130 7.0 18 10.875 5.6 12.17 na 19.54 0.1 130 7.0 19 10.875 5.6 13.68 na 20.71 0.1 130 7.0 20 10.875 5.6 16.42 na 22.69 0.1 130 7.0 21 10.875 5.6 18.53 na 24.11 0.1 130 7.0 22 10.292 28.72 na 23 13.292 5.6 24.44 na 27.69 0.1 130 7.0 24 13.292 5.6 24.88 na 27.93 0.1 130 7.0 25 13.292 5.6 26.47 na 28.81 0.1 130 7.0 26 13.292 5.6 28.1 na 29.68 0.1 130 7.0 27 10.292 39.11 na 28 10.292 40.45 na 67 8.833 45.34 na 102 11.125 54.86 na 103 11.125 56.74 na 104 11.125 66.0 na 134 11.125 69.94 na 135 11.125 73.06 na 136 11.125 78.42 na TOR 11.125 83.72 na BOR 0.5 89.61 na UG1 -5.5 92.38 na DCI -10.833 97.38 na DC2 -10.833 100.65 na HYD -11.833 101.59 na 100.0 SRC 0.0 96.46 na The maximum velocity is 30.64 and it occurs in the pipe between nodes 22 and 28 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 5 OMWD AREA 1 Date 7/21/19 Nodel Elevl K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 1 10.875 5.60 14.82 1 0.0 8.000 120 7.000 to 0.0 0.0 0.0 2 10.875 14.82 1.083 0.0 8.000 0.0640 0.512 Vel = 5.16 2 10.875 5.60 15.34 1 0.0 8.000 120 7.512 to 0.0 0.0 0.0 3 10.875 30.16 1.083 0.0 8.000 0.2382 1.906 Vel = 10.50 3 10.875 5.60 17.19 1.25 0.0 8.000 120 9.418 to 0.0 0.0 0.0 4 10.875 47.35 1.418 0.0 8.000 0.1476 1.181 Vel = 9.62 4 10.875 5.60 18.23 1.25 0.0 4.375 120 10.599 to 0.0 0.0 0.0 5 10.875 65.58 1.418 0.0 4.375 0.2699 1.181 Vel = 13.32 5 10.875 5.60 19.22 1.25 0.0 3.625 120 11.780 to 0.0 0.0 0.0 6 10.875 84.8 1.418 0.0 _3.625 0.4339 1.573 Vel = 17.23 6 10.875 5.60 20.46 1.5 0.0 8.000 120 13.353 to 0.0 0.0 0.0 7 10.875 105.26 1.654 0.0 8.000 0.3059 2.447 Vel = 15.72 7 10.875 5.60 22.26 1.5 E 4.561 11.250 120 15.800 to T 9.123 13.684 0.252 8 10.292 127.52 1.654 0.0 24.934 0.4363 10.878 Vel = 19.04 8 10.292 0.0 2 0.0 8.625 120 26.930 to 0.0 0.0 0.0 15 10.292 127.52 2.203 0.0 8.625 0.1081 0.932 Vel = 10.73 0.0 15 127.52 27.862 KFactor= 24.16 9 13.292 5.60 15.99 1 0.0 8.000 120 8.153 to 0.0 0.0 0.0 10 13.292 15.99 1.083 0.0 8.000 0.0736 0.589 Vel = 5.57 10 13.292 5.60 16.56 1 0.0 8.000 120 8.742 to 0.0 0.0 0.0 11 13.292 32.55 1.083 0.0 8.000 0.2742 2.194 Vel= 11.34 11 13.292 5.60 18.52 1.25 0.0 8.000 120 10.936 to 0.0 0.0 0.0 12 13.292 51.07 1.418 0.0 8.000 0.1699 1.359 Vel = 10.38 12 13.292 5.60 19.63 1.25 0.0 8.000 120 12.295 to 0.0 0.0 0.0 13 13.292 70.7 1.418 0.0 8.000 0.3100 2.480 Vel = 14.36 13 13.292 5.60 21.53 1.5 0.0 8.000 120 14.775 to 0.0 0.0 0.0 14 13.292 92.23 1.654 0.0 8.000 0.2395 1.916 Vel = 13.77 14 13.292 5.60 22.88 1.5 E 4.561 13.667 120 16.691 to T 9.123 13.684 1.299 15 10.292 115.11 1.654 0.0 27.351 0.3609 9.872 Vel = 17.19 15 10.292 127.52 2 0.0 2.417 120 27.862 to 0.0 0.0 0.0 22 10.292 242.63 2.203 0.0 2.417 0.3550 0.858 Vel = 20.42 0.0 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 6 OMWD AREA 1 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 22 242.63 28.720 K Factor= 45.27 16 10.875 5.60 16.89 1 0.0 8.000 120 9.096 to 0.0 0.0 0.0 17 10.875 16.89 1.083 0.0 8.000 0.0814 0.651 Vet = 5.88 17 10.875 5.60 17.48 1 0.0 8.000 120 9.747 to 0.0 0.0 0.0 18 10.875 34.37 1.083 0.0 8.000 0.3035 2.428 Vet = 11.97 18 10.875 5.60 19.54 1.25 0.0 8.000 120 12.175 to 0.0 0.0 0.0 19 10.875 53.91 1.418 0.0 8.000 0.1878 1.502 Vet = 10.95 19 10.875 5.60 20.71 1.25 0.0 8.000 120 13.677 to 0.0 0.0 0.0 20 10.875 74.62 1.418 0.0 8.000 0.3426 2.741 Vet = 15.16 20 10.875 5.60 22.69 1.5 0.0 8.000 120 16.418 to 0.0 0.0 0.0 21 10.875 97.31 1.654 0.0 8.000 0.2645 2.116 Vel= 14.53 21 10.875 5.60 24.11 1.5 E 4.561 11.250 120 18.534 to T 9.123 13.684 0.252 22 10.292 121.42 1.654 0.0 24.934 0.3984 9.934 Vel = 18.13 22 10.292 242.63 2 X 11.593 4.000 120 28.720 to 0.0 11.593 0.0 28 10.292 364.05 2.203 0.0 15.593 0.7522 11.729 Vet = 30.64 0.0 28 364.05 40.449 K Factor= 57.24 23 13.292 5.60 27.68 1.25 0.0 8.000 120 24.441 to 0.0 0.0 0.0 24 13.292 27.68 1.418 0.0 8.000 0.0546 0.437 Vel= 5.62 24 13.292 5.60 27.94 1.25 0.0 8.000 120 24.878 to 0.0 0.0 0.0 25 13.292 55.62 1.418 0.0 8.000 0.1990 1.592 Vet = 11.30 25 13.292 5.60 28.81 1.5 0.0 8.000 120 26.470 to 0.0 0.0 0.0 26 13.292 84.43 1.654 0.0 8.000 0.2034 1.627 Vet = 12.61 26 13.292 5.60 29.68 1.5 E 4.561 13.667 120 28.097 to T 9.123 13.684 1.299 27 10.292 114.11 1.654 0.0 27.351 0.3552 9.715 Vet = 17.04 27 10.292 0.0 2 X 11.593 3.625 120 39.111 to 0.0 11.593 0.0 28 10.292 114.11 2.203 0.0 15.218 0.0879 1.338 Vet = 9.60 28 10.292 364.05 3 V 7.496 18.250 120 40.449 to 0.0 7.496 0.632 67 8.833 478.16 3.334 0.0 25.746 0.1656 4.263 Vet = 17.57 67 8.833 0.0 3 2V 14.992 25.958 120 45.344 to T 22.488 37.480 -0.993 102 11.125 478.16 3.334 0.0 63.438 0.1656 10.505 Vet = 17.57 102 11.125 0.0 3 V 7.496 3.875 120 54.856 to 0.0 7.496 0.0 103 11.125 478.16 3.334 0.0 11.371 0.1656 1.883 Vet= 17.57 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 7 OMWD AREA I Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 103 11.125 0.0 3 0.0 55.958 120 56.739 to 0.0 0.0 0.0 104 11.125 478.16 3.334 0.0 55.958 0.1656 9.266 Vel = 17.57 104 11.125 0.0 3 0.0 23.792 120 66.005 to 0.0 0.0 0.0 134 11.125 478.16 3.334 0.0 23.792 0.1656 3.940 Vel = 17.57 134 11.125 0.0 3 0.0 18.833 120 69.945 to 0.0 0.0 0.0 135 11.125 478.16 3.334 0.0 18.833 0.1656 3.118 Vel= 17.57 135 11.125 0.0 3 0.0 32.333 120 73.063 to 0.0 0.0 0.0 136 11.125 478.16 3.334 0.0 32.333 0.1656 5.354 Vel = 17.57 136 11.125 0.0 3 V 7.496 24.500 120 78.417 to 0.0 7.496 0.0 TOR 11.125 478.16 3.334 0.0 31.996 0.1656 5.298 Vel = 17.57 TOR 11.125 0.0 4 B 16.724 10.625 120 83.715 to 0.0 16.724 4.602 BOR .500 478.16 4.31 0.0 27.349 0.0474 1.297 Vel = 10.51 BOR .500 0.0 6 L 11.316 12.000 120 89.614 to 0.0 11.316 2.599 UG1 -5.500 478.16 6.357 0.0 23.316 0.0071 0.166 Vel = 4.83 UGI -5.500 0.0 6 2L 23.005 315.000 150 92.379 to 5F 44.733 67.738 2.310 DC1 -10.833 478.16 5.86 0.0 382.738 0.0070 2.690 Vel = 5.69 DC1 -10.833 0.0 6 T 43.037 24.000 140 97.379 to 2E 40.168 83.205 2.602 * * Fixed Loss = 2.602 DC2 -10833 478.16 6.16 Zaf 0.0 107.205 0.0063 0.671 Vel = 5.15 DC2 -10.833 0.0 6 G 4.304 33.000 140 100.652 to T 43.037 47.341 0.433 HYD -11.833 478.16 6.16 0.0 80.341 0.0063 0.504 Vel = 5.15 HYD -11.833 H100 100.00 6 0.0 0.100 140 101.589 to 0.0 0.0 -5.125 SRC 0 578.16 6.16 0.0 0.100 0.0100 0.001 Vel = 6.22 0.0 SRC 578.16 96.465 KFactor= 58.87 Computer Programs by Hydratec Inc. Revision: 50.53.5 Hamilton Fire Protection Page 8 OMWD AREA 2 Date 7/21/19 Hydraulic Design Information Sheet Name - OMWD AREA 2 Date - 7-21-19 Location - 1966 OLIVENHAIN RD ENCINITAS Building - System No. - Contractor - Contract No. - Calculated By - Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 10 FT Occupancy - UNUSED ATTIC SPACE S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1180 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make TYCO D Area Per Sprinkler - 130 ( ) Dry Model TYFRB E Elevation at Highest Outlet - 26.250 ( ) Deluge Size 1/2 S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 410.3 Press Required - 88.5 BOR Summary C-Factor Used: 120 Overhead 150 Underground Pump Data: Tank or Reservoir: Cap. - Rated Cap.- Elev.- @ Press - Elev. - Well Proof Flow Water Flow Test: Date of Test - 5/30/19 Time of Test - Static Press - 140 Residual Press - 138 Flow - 1630 Elevation - 0 Location - 1966 OLIVENHAIN RD Source of Information - OMWD W A T E R S U P P L Y C 0 M M SR TA O C R K A G E Commodity Class Location Storage Ht. Area Aisle W. Storage Method: Solid Piled % Palletized % Rack Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non Mult. Row ( ) Open Shelf Flue Spacing Clearance:Storage to Ceiling Longitudinal Transverse Horizontal Barriers Provided: Water Supply Curve C Hamilton Fire Protection Page 9 OMWD AREA 2 Date 7/21/19 City Water Supply: Demand: Cl - Static Pressure : 103 Dl - Elevation : 11.369 C2- Residual Pressure: 100 D2 - System Flow : 410.296 C2 - Residual Flow : 1630 D2 - System Pressure : 94.354 Hose (Demand) :100 03 - System Demand : 510.296 Safety Margin : 8.296 150 140 130 p120 R° C1 C2 E 100 V2 -0 s 90 D3 80 u 70 R60 E5° 40 30 20 10 UI— _J_ ......_........ .. .... ..... 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Hamilton Fire Protection Page 10 OMWD AREA 2 Date 7/21/19 Filling Legend Abbrev. Name 'A % 1 1½ 1½ 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA1S45Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 13 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90 Eli Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 4.5 5.1 0 0 0 0 0 X 90Tee-BranchFirelockO02 0 0 0 0 0 8.5 10.8 13 0 16 21 25 33 9.3 11 0 0 0 0 0 Zaf Ames 3000SS Filling generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Nydratec Inc. Revision: 50.53.5 Pressure / Flow Summary - STANDARD Hamilton Fire Protection Page 11 OMWD AREA 2 Date 7/21/19 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 29 23.583 5.6 7.64 na 15.47 0.1 130 7.0 30 23.583 5.6 8.16 na 15.99 0.1 130 7.0 31 23.583 9.68 na 32 23.583 5.6 9.79 na 17.52 0.1 130 7.0 33 23.583 5.6 10.97 na - 18.55 0.1 130 7.0 34 23.583 5.6 13.11 na 20.27 0.1 130 7.0 35 23.583 5.6 14.66 na 21.44 0.1 130 7.0 36 23.583 21.71 na 37 22.917 25.21 na 38 26.25 5.6 7.04 na 14.85 0.1 130 7.0 39 26.25 5.6 7.52 na 15.35 0.1 130 7.0 40 26.25 5.6 9.31 na 17.09 0.1 130 7.0 41 26.25 5.6 10.41 na 18.07 0.1 130 7.0 42 26.25 5.6 12.43 na 19.74 0.1 130 7.0 43 26.25 5.6 13.89 na 20.87 0.1 130 7.0 44 26.25 20.56 na 45 22.917 25.86 na 46 25.25 24.74 na 47 25.25 24.74 na 48 22.917 25.75 na 49 26.25 5.6 7.0 na 14.82 0.1 130 7.0 50 26.25 5.6 7.48 na 15.32 0.1 130 7.0 51 26.25 5.6 9.26 na 17.04 0.1 130 7.0 52 26.25 5.6 10.36 na 18.03 0.1 130 7.0 53 26.25 5.6 12.37 na 19.69 0.1 130 7.0 54 26.25 5.6 13.82 na 20.82 0.1 130 7.0 55 26.25 20.46 na 56 22.917 25.75 na 57 23.583 5.6 13.31 na 20.43 0.1 130 7.0 58 23.583 14.88 na 59 23.583 5.6 14.89 na 21.61 0.1 130 7.0 60 23.583 5.6 16.55 na 22.78 0.1 130 7.0 61 23.583 19.06 na 62 23.583 5.6 19.19 na 24.53 0.1 130 7.0 63 23.583 23.63 na 64 22.917 26.13 na 65 22.917 29.6 na 66 8.833 42.88 na 67 8.833 54.28 na 102 11.125 61.2 na 103 11.125 62.62 na 104 11.125 69.6 na 134 11.125 72.57 na 135 11.125 74.92 na 136 11.125 78.95 na TOR 11.125 82.94 na BOR 0.5 88.52 na UG1 -5.5 91.24 na DC1 -10.833 95.58 na DC2 -10.833 98.67 na HYD -11.833 99.48 na 100.0 SRC 0.0 94.35 na The maximum velocity is 22.91 and it occurs in the pipe between nodes 65 and 66 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 12 OMWD AREA 2 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 29 23.583 5.60 15.47 1 0.0 7.500 120 7.636 to 0.0 0.0 0.0 30 23.583 15.47 1.083 0.0 7.500 0.0693 0.520 Vel = 5.39 30 23.583 5.60 16.00 1 0.0 5.917 120 8.156 to 0.0 0.0 0.0 31 23.583 31.47 1.083 0.0 5.917 0.2576 1.524 Vet = 10.96 31 23.583 0.0 1.25 0.0 1.583 120 9.680 to 0.0 0.0 0.0 32 23.583 31.47 1.418 0.0 1.583 0.0695 0.110 Vet = 6.39 32 23.583 5.60 17.52 1.25 0.0 7.500 120 9.790 to 0.0 0.0 0.0 33 23.583 48.99 1.418 0.0 7.500 0.1573 1.180 Vet = 9.95 33 23.583 5.60 18.55 1.25 0.0 7.500 120 10.970 to 0.0 0.0 0.0 34 23.583 67.54 1.418 0.0 7.500 0.2848 2.136 Vet = 13.72 34 23.583 5.60 20.27 1.5 0.0 7.083 120 13.106 to 0.0 0.0 0.0 35 23.583 87.81 1.654 0.0 7.083 0.2187 1.549 Vet = 13.11 35 23.583 5.60 21.44 1.5 T 9.123 12.417 120 14.655 to 0.0 9.123 0.0 36 23.583 109.25 1.654 0.0 21.540 0.3277 7.059 Vet = 16.31 36 23.583 0.0 1.5 T 9.123 0.667 120 21.714 to 0.0 9.123 0.288 37 22.917 109.25 1.654 - 0.0 9.790 0.3277 3.208 Vet = 16.31 37 22.917 0.0 2 0.0 8.042 120 25.210 to 0.0 0.0 0.0 45 22.917 109.25 2.203 0.0 8.042 0.0812 0.653 Vet = 9.20 0.0 45 109.25 25.863 K Factor= 21.48 38 26.250 5.60 14.85 1 0.0 7.500 120 7.036 to 0.0 0.0 0.0 39 26.250 14.85 1.083 0.0 7.500 0.0643 0.482 Vel = 5.17 39 26.250 5.60 15.36 1 0.0 7.500 120 7.518 to 0.0 0.0 0.0 40 26.250 30.21 1.083 0.0 7.500 0.2389 1.792 Vel= 10.52 40 26.250 5.60 17.08 1.25 0.0 7.500 120 9.310 to 0.0 0.0 0.0 41 26.250 47.29 1.418 0.0 7.500 0.1473 1.105 Vel= 9.61 41 26.250 5.60 18.08 1.25 0.0 7.500 120 10.415 to 0.0 0.0 0.0 42 26.250 65.37 1.418 0.0 7.500 0.2681 2.011 Vel = 13.28 42 26.250 5.60 19.74 1.5 0.0 7.083 120 12.426 to 0.0 0.0 0.0 43 26.250 85.11 1.654 0.0 7.083 0.2064 1.462 Vel = 12.71 43 26.250 5.60 20.87 1.5 T 9.123 12.417 120 13.888 to 0.0 9.123 0.0 44 26.250 105.98 1.654 0.0 21.540 0.3098 6.673 Vet = 15.82 44 26.250 0.0 1.5 T 9.123 3.333 120 20.561 to 0.0 9.123 1.444 45 22.917 105.98 1.654 0.0 12.456 0.3097 3.858 Vet = 15.82 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 13 OMWD AREA 2 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 45 22.917 109.24 2 X 11.593 1.542 120 25.863 to 0.0 11.593 0.0 65 22.917 215.22 2.203 0.0 13.135 0.2844 3.736 Vel= 18.12 0.0 65 215.22 29.599 KFactor= 39.56 46 25.250 0.0 1.5 T 9.123 12.417 120 24.736 to 0.0 9.123 0.0 47 25.250 0.0 1.654 0.0 21.540 0 0.0 Vel = 0 47 25.250 0.0 1.5 T 9.123 2.333 120 24.736 to 0.0 9.123 1.010 48 22.917 0.0 1.654 0.0 11.456 0 0.0 Vel = 0 48 22.917 0.0 2 0.0 3.083 120 25.746 to 0.0 0.0 0.0 56 22.917 0.0 2.203 0.0 3.083 0 0.0 Vel = 0 0.0 56 0.0 25.746 K Factor =0 49 26.250 5.60 14.82 1 0.0 7.500 120 7.000 to 0.0 0.0 0.0 50 26.250 14.82 1.083 0.0 7.500 0.0640 0.480 Vel = 5.16 50 26.250 5.60 15.31 1 0.0 7.500 120 7.480 to 0.0 0.0 0.0 51 26.250 30.13 1.083 0.0 7.500 0.2377 1.783 Vel = 10.49 51 26.250 5.60 17.05 1.25 0.0 7.500 120 9.263 to 0.0 0.0 0.0 52 26.250 47.18 1.418 0.0 7.500 0.1467 1.100 VeI= 9.59 52 26.250 5.60 18.02 1.25 0.0 7.500 120 10.363 to 0.0 0.0 0.0 53 26.250 65.2 1.418 0.0 7.500 0.2669 2.002 Vel = 13.25 53 26.250 5.60 19.69 1.5 0.0 7.083 120 12.365 to 0.0 0.0 0.0 54 26.250 84.89 1.654 0.0 7.083 0.2056 1.456 Vel = 12.68 54 26.250 5.60 20.82 1.5 T 9.123 12.417 120 13.821 to 0.0 9.123 0.0 55 26.250 105.71 1.654 0.0 21.540 0.3083 6.641 Vel = 15.78 55 26.250 0.0 1.5 T 9.123 3.333 120 20.462 to 0.0 9.123 1.444 56 22.917 105.71 1.654 0.0 12.456 0.3083 3.840 Vel = 15.78 56 22.917 0.0 2 0.0 5.000 120 25.746 to 0.0 0.0 0.0 64 22.917 105.71 2.203 0.0 5.000 0.0764 0.382 Vel = 8.90 0.0 64 105.71 26.128 KFactor= 20.68 57 23.583 5.60 20.43 1 0.0 13.500 120 13.311 to 0.0 0.0 0.0 58 23.583 20.43 1.083 0.0 13.500 0.1159 1.565 Vel = 7.12 58 23.583 0.0 1.25 0.0 0.500 120 14.876 to 0.0 0.0 0.0 59 23.583 20.43 1.418 0.0 0.500 0.0300 0.015 Vel = 4.15 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 14 OMWD AREA 2 Date 7/21/19 Nodel Elevl K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 59 23.583 5.60 21.61 1.25 0.0 14.000 120 14.891 to 0.0 0.0 0.0 60 23.583 42.04 1.418 0.0 14.000 0.1186 1.660 Vel = 8.54 60 23.583 5.60 22.78 1.25 0.0 9.500 120 16.551 to 0.0 0.0 0.0 61 23.583 64.82 1.418 0.0 9.500 0.2640 2.508 Vel = 13.17 61 23.583 0.0 1.5 0.0 1.083 120 19.059 to 0.0 0.0 0.0 62 23.583 64.82 1.654 0.0 1.083 0.1247 0.135 Vel = 9.68 62 23.583 5.60 24.54 1.5 1 9.123 10.500 120 19.194 to 0.0 9.123 0.0 63 23.583 89.36 1.654 0.0 19.623 0.2260 4.434 Vel = 13.34 63 23.583 0.0 1.5 T 9.123 0.667 120 23.628 to 0.0 9.123 0.288 64 22.917 89.36 1.654 0.0 9.790 0.2259 2.212 Vel = 13.34 64 22.917 105.71 2 X 11.593 3.042 120 26.128 to 0.0 11.593 0.0 65 22.917 195.07 2.203 0.0 14.635 0.2372 3.471 Vel = 16.42 65 22.917 215.23 2.5 V 6.707 14.083 120 29.599 to 0.0 6.707 6.100 66 8.833 410.3 2.705 0.0 20.790 0.3453 7.179 Vel = 22.91 66 8.833 0.0 2.5 T 18.718 14.292 120 42.878 to 0.0 18.718 0.0 67 8.833 410.3 2.705 0.0 33.010 0.3453 11.399 Vel = 22.91 67 8.833 0.0 3 2V 14.992 25.958 120 54.277 to T 22.488 37.480 -0.993 102 11.125 410.3 3.334 0.0 63.438 0.1248 7.914 Vel = 15.08 102 11.125 0.0 3 V 7.496 3.875 120 61.198 to 0.0 7.496 0.0 103 11.125 410.3 3.334 0.0 11.371 0.1248 1.419 Vel = 15.08 103 11.125 0.0 3 0.0 55.958 120 62.617 to 0.0 0.0 0.0 104 11.125 410.3 3.334 0.0 55.958 0.1248 6.981 Vel = 15.08 104 11.125 0.0 3 0.0 23.792 120 69.598 to 0.0 0.0 0.0 134 11.125 410.3 3.334 0.0 23.792 0.1247 2.968 Vel = 15.08 134 11.125 0.0 3 0.0 18.833 120 72.566 to 0.0 0.0 0.0 135 11.125 410.3 3.334 0.0 18.833 0.1247 2.349 Vel= 15.08 135 11.125 0.0 3 0.0 32.333 120 74.915 to 0.0 0.0 0.0 136 11.125 410.3 3.334 0.0 32.333 0.1248 4.034 Vel= 15.08 136 11.125 0.0 3 V 7.496 24.500 120 78.949 to 0.0 7.496 0.0 TOR 11.125 410.3 3.334 0.0 31.996 0.1247 3.991 Vel = 15.08 TOR 11.125 0.0 4 B 16.724 10.625 120 82.940 to 0.0 16.724 4.602 BOR .500 410.3 4.31 0.0 27.349 0.0357 0.977 Vel = 9.02 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 15 OMWD AREA 2 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf BOR .500 0.0 6 L 11.316 12.000 120 88.519 to 0.0 11.316 2.599 UG1 -5.500 410.3 6.357 0.0 23.316 0.0054 0.125 Vel = 4.15 UGI -5.500 0.0 6 2L 23.005 315.000 150 91.243 to 5F 44.733 67.738 2.310 DC1 -10.833 410.3 5.86 0.0 382.738 0.0053 2.027 Vel = 4.88 DC1 -10.833 0.0 6 T 43.037 24.000 140 95.580 to 2E 40.168 83.205 2.580 * * Fixed Loss = 2.58 DC2 -10.833 410.3 6.16 Zaf 0.0 107.205 0.0047 0.506 Vel = 4.42 DC2 -10.833 0.0 6 G 4.304 33.000 140 98.666 to T 43.037 47.341 0.433 HYD -11.833 410.3 6.16 0.0 80.341 0.0047 0.379 Vel= 4.42 HYD -11.833 HIM 100.00 6 0.0 0.100 140 99.478 to 0.0 0.0 -5.125 SRC 0 510.3 6.16 0.0 0.100 0.0100 0.001 Vel = 5.49 0.0 SRC 510.30 94.354 KFactor= 52.53 Computer Programs by Hydratec Inc. Revision: 50.53.5 Hamilton Fire Protection Page 16 OMWD AREA 3 Date 7/21/19 Hydraulic Design Information Sheet Name - OMWD AREA 3 Date - 7-21-19 Location - 1966 OLIVENHAIN RD ENCINITAS Building - System No. - Contractor - Contract No. - Calculated By - Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 15 FT Occupancy - UNUSED ATTIC SPACE (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. NFPA 231 ( ) NFPA 231C ( ) Figure Curve Other Specific Ruling Made By Date Area of Sprinkler Operation - 1373 Density - .10 Area Per Sprinkler - 130 Elevation at Highest Outlet - 20.42' Hose Allowance - Inside - Rack Sprinkler Allowance - Hose Allowance - Outside - 100 Note Calculation Flow Required - 329.7 Press Required - 92.0 BOR Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 5/30/19 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 140 @ Press - R Residual Press - 138 Elev. - Well Flow - 1630 Proof Flow S Elevation - 0 U P Location - 1966 OLIVENHAIN RD P L Source of Information - OMWD Y C Commodity Class Location O Storage Ht. Area Aisle W. N Storage Method: Solid Piled % Palletized % Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: S V S T E N D E S I G N System Type Sprinkler/Nozzle (X) Wet Make TYCO Dry Model TYFRB Deluge Size 1/2 Preaction K-Factor =BL2 Other Temp.Rat.200 Water Supply Curve C Hamilton Fire Protection Page 17 OMWD AREA 3 Date 7/21/19 City Water Supply: Demand: Cl -Static Pressure : 103 Dl - Elevation : 4.475 C2- Residual Pressure: 100 D2 - System Flow : 329.692 C2 - Residual Flow : 1630 D2 - System Pressure : 97.012 Hose (Demand) :100 03 - System Demand : 429.692 Safety Margin : 5.733 150 140 130 p120 R° Cl C2 E IUU 90 j 80 U 70 R6° E 50 40 30 20 ni 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N " 1.85) Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Hamilton Fire Protection Page 18 OMWD AREA 3 Date 7/21/19 Fitting Legend Abbrev. Name ½ 3/4 1 1% 11/2 2 21/2 3 3½ 4 5 6 8 10 12 14 16 18 20 24 B NFPAI3 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPAI3 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 Mfx Metraflex Loop Fitting generates a Fixed Loss Based on Flow T NFPA 13 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90 Ell Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.6 10 13 4.5 5.1 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Pressure / Flow Summary - STANDARD Hamilton Fire Protection Page 19 OMWD AREA 3 Date 7/21/19 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. SP1 -4.5 5.6 7.0 na 14.82 0.1 130 7.0 SP2 -1.0 5.6 7.0 na 14.82 0.1 130 7.0 SP3 -1.0 5.6 7.0 na 14.82 0.1 130 7.0 SP4 -1.0 5.6 7.0 na 14.82 0.1 130 7.0 68 18.0 K= K @ BL1 7.31 na 16.04 69 18.0 K= K@ BLI 8.09 na 16.88 70 18.0 9.83 na 71 18.0 K= K@ BLI 10.24 na 18.99 72 18.0 K= K @ BLI 12.28 na 20.8 73 17.667 13.54 na 74 11.708 23.27 na 75 10.333 K= K @ 131-2 6.97 na 14.82 76 9.833 8.2 na 77 10.333 K= K@ 131-3 8.23 na 15.84 78 10.333 K= K@ 131-3 8.56 na 16.16 79 10.333 K= K@ 131-3 9.36 na 16.89 80 10.333 K=K@BL3 10.77 na 18.12 81 10.333 K= K@ BL4 17.22 na 22.57 82 10.333 18.62 na 83 11.708 23.29 na 84 19.875 K= K@BLI 6.33 na 14.93 85 20.417 K= K @ BL1 7.45 na 16.2 86 20.417 9.02 na 87 20.417 K= K @ BL1 9.39 na 18.18 88 19.625 K= K@ BLI 13.94 na 22.15 89 18.958 19.51 na 90 11.708 24.42 na 91A 19.875 K= K @ BL1 8.18 na 16.97 91 20.417 K= K@ BL1 9.67 na 18.45 92 20.417 11.66 na 93 20.417 K= K@ BL1 12.13 na 20.67 94 19.625 K= K @ BL1 17.82 na 25.05 95 18.958 19.3 na 96 11.708 28.13 na 97 11.125 38.69 na 98 11.125 45.75 na 99 11.125 62.62 na 100 11.125 65.1 na 101 11.125 68.57 na 102 11.125 72.27 na 103 11.125 73.22 na 104 11.125 77.87 na 134 11.125 79.85 na 135 11.125 81.42 na 136 11.125 84.11 na TOR 11.125 86.78 na BOR 0.5 92.03 na UGI -5.5 94.71 na DC1 -10.833 98.37 na DC2 -10.833 101.45 na HYD -11.833 102.14 na 100.0 SRC 0.0 97.01 na The maximum velocity is 27.75 and it occurs in the pipe between nodes 96 and 97 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 20 OMWD AREA 3 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf SPI -4.500 5.60 14.82 1 2E 4.672 8.000 120 7.000 to T 5.84 10.512 -1.949 BL1 0 14.82 1.083 0.0 18.512 0.0640 1.184 Vel = 5.16 0.0 BL1 14.82 6.235 K Factor = 5.94 SP2 -1 5.60 14.82 1 2E 4.672 1.667 120 7.000 to 0.0 4.672 -0.433 BL2 0 14.82 1.083 0.0 6.339 0.0639 0.405 Vel = 5.16 0.0 BL2 14.82 6.972 K Factor = 5.61 SP3 -1 5.60 14.82 1 E 2.336 1.667 120 7.000 to T 5.84 8.176 -0.433 BL3 0 14.82 1.083 0.0 9.843 0.0639 0.629 Vel = 5.16 0.0 BL3 14.82 7.196 K Factor = 5.52 SP4 -1 5.60 14.82 1 T 5.84 2.833 120 7.000 to 2E 4.672 10.512 -0.433 BL4 0 14.82 1.083 0.0 13.345 0.0639 0.853 Vel = 5.16 0.0 BL4 14.82 7.420 K Factor = 5.44 68 18 5.93 16.04 1 0.0 10.583 120 7.307 K = K © BLI to 0.0 0.0 0.0 69 18 16.04 1.083 0.0 10.583 0.0740 0.783 Vel = 5.59 69 18 5.93 16.88 1 0.0 6.208 120 8.090 K= K@ BL1 to 0.0 0.0 0.0 70 18 32.92 1.083 0.0 6.208 0.2801 1.739 Vel = 11.47 70 18 0.0 1.25 0.0 5.458 120 9.829 to 0.0 0.0 0.0 71 18 32.92 1.418 0.0 5.458 0.0753 0.411 Vel = 6.69 71 18 5.93 18.98 1.25 0.0 11.667 120 10.240 K= K@ BLI to 0.0 0.0 0.0 72 18 51.9 1.418 0.0 11.667 0.1750 2.042 Vel= 10.54 72 18 5.93 20.80 1.25 0.0 3.417 120 12.282 K = K @ BLI to 0.0 0.0 0.144 73 17.667 72.7 1.418 0.0 3.417 0.3266 1.116 Vel = 14.77 73 17.667 0.0 1.5 5E 22.806 14.375 120 13.542 to T 9.123 31.929 2.581 74 11.708 72.7 1,654 0.0 46.304 0.1542 7.142 Vel= 10.86 74 11.708 0.0 2 0.0 0.708 120 23.265 to 0.0 0.0 0.0 83 11.708 72.7 2.203 0.0 0.708 0.0381 0.027 Vel = 6.12 0.0 83 72.70 23.292 KFactor= 15.06 75 10.333 5.61 14.82 1 2E 4.672 11.208 120 6.972 K= K@BL2 to 0.0 4.672 0.217 76 9.833 14.82 1.083 0.0 15.880 0.0639 1.015 Vet = 5.16 76 9.833 0.0 1.25 2E 6.849 7.167 120 8.204 to 0.0 6.849 -0.217 77 10.333 14.82 1.418 0.0 14.016 0.0173 0.242 Vel = 3.01 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 21 OMWD AREA 3 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 77 10.333 5.52 15.84 1.5 0.0 10.583 120 8.229 K = K@ BL3 to 0.0 0.0 0.0 78 10.333 30.66 1.654 0.0 10.583 0.0313 0.331 Vel = 4.58 78 10.333 5.52 16.16 1.5 0.0 11.667 120 8.560 K= K @ BU to 0.0 0.0 0.0 79 10.333 46.82 1.654 0.0 11.667 0.0683 0.797 Vel = 699 79 10.333 5.52 16.89 1.5 0.0 11.667 120 9.357 K= K @ BL3 to 0.0 0.0 0.0 80 10.333 63.71 1.654 0.0 11.667 0.1209 1.410 Vel = 9.51 80 10.333 5.52 18.13 1.5 4E 18.245 13.542 120 10.767 K= K@ BL3 to T 9.123 27.368 0.0 82 10.333 81.84 1.654 0.0 40.910 0.1920 7.855 Vel = 12.22 0.0 82 81.84 18.622 KFactor= 18.96 81 10.333 5.44 22.57 1 T 5.84 4.250 120 17.216 K = K @ BL4 to 0.0 5.840 0.0 82 10.333 22.57 1.083 0.0 10.090 0.1393 1.406 Vel = 7.86 82 10.333 81.83 1.5 E 4.561 3.792 120 18.622 to T 9.123 13.684 -0.596 83 11.708 104.4 1.654 0.0 17.476 0.3013 5.266 Vel = 15.59 83 11.708 72.70 2 0.0 5.667 120 23.292 to 0.0 0.0 0.0 90 11.708 177.1 2.203 0.0 5.667 0.1983 1.124 Vel = 14.91 0.0 90 177.10 24.416 K Factor= 35.84 84 19.875 5.93 14.93 1 4E 9.344 11.583 120 6.328 K=K@BL1 to 0.0 9.344 -0.235 85 20.417 14.93 1.083 0.0 20.927 0.0648 1.357 Vel = 5.20 85 20.417 5.93 16.19 1 0.0 6.208 120 7.450 K = K @ BL1 to 0.0 0.0 0.0 86 20.417 31.12 1.083 0.0 6.208 0.2524 1.567 Vel = 10.84 86 20.417 0.0 1.25 0.0 5.458 120 9.017 to 0.0 0.0 0.0 87 20.417 31.12 1.418 0.0 5.458 0.0680 0.371 Vel = 6.32 87 20.417 5.93 18.18 1.25 4E 13.697 12.750 120 9.388 K = K @ BL1 to 0.0 13.697 0.343 88 19.625 49.3 1.418 0.0 26.447 0.1591 4.209 Vel = 10.02 88 19.625 5.93 22.16 1.25 2E 6.849 3.000 120 13.940 K = K @ BL1 to T 6.849 13.698 0.289 89 18.958 71.46 1.418 0.0 16.698 0.3161 5.279 Vel = 14.52 89 18.958 0.0 1.5 0.0 11.833 120 19.508 to 0.0 0.0 3.140 90 11.708 71.46 1.654 0.0 11.833 0.1494 1.768 Vel = 10.67 90 11.708 177.10 2 0.0 10.000 120 24.416 to 0.0 0.0 0.0 96 11.708 248.56 2.203 0.0 10.000 0.3713 3.713 Vel = 20.92 0.0 96 248.56 28.129 KFactor= 46.87 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 22 OMWD AREA 3 Date 7/21/19 Nodel Etevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Etev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 91A 19.875 5.93 16.97 1 4E 9.344 11.583 120 8.182 K= K@BL1 to 0.0 9.344 -0.235 91 20.417 16.97 1.083 0.0 20.927 0.0822 1.721 Vet = 5.91 91 20.417 5.93 18.45 1 0.0 6.208 120 9.668 K= K @ BLI to 0.0 0.0 0.0 92 20.417 35.42 1.083 0.0 6.208 0.3207 1.991 Vel= 12.34 92 20.417 0.0 1.25 0.0 5.458 120 11.659 to 0.0 0.0 0.0 93 20.417 35.42 1.418 0.0 5.458 0.0863 0.471 Vet = 7.20 93 20.417 5.93 20.67 1.25 4E 13.697 12.750 120 12.130 K= K @ BLI to 0.0 13.697 0.343 94 19.625 56.09 1.418 0.0 26.447 0.2020 5.343 Vet = 11.40 94 19.625 5.93 25.04 1.25 0.0 3.000 120 17.816 K= K © BL1 to 0.0 0.0 0.289 95 18.958 81.13 1.418 0.0 3.000 0.4000 1.200 Vet = 16.48 95 18.958 0.0 1.5 2E 9.123 11.833 120 19.305 to T 9.123 18.246 3.140 96 11.708 81.13 1.654 0.0 30.079 0.1890 5.684 Vet = 12.11 96 11.708 248.56 2 2V 9.547 6.917 120 28.129 to 0.0 9.547 0.252 97 11.125 329.69 2.203 0.0 16.464 0.6262 10.309 Vet = 27.75 97 11.125 0.0 2 V 4.774 6.500 120 38.690 to 0.0 4.774 0.0 98 11.125 329.69 2.203 0.0 11.274 0.6262 7.060 Vet = 27.75 98 11.125 0.0 2 V 4.774 22.167 120 45.750 to 0.0 4.774 0.0 99 11.125 329.69 2.203 0.0 26.941 0.6261 16.868 Vet = 27.75 99 11.125 0.0 3 0.0 29.833 120 62.618 to 0.0 0.0 0.0 100 11.125 329.69 3.334 0.0 29.833 0.0833 2.484 Vet = 12.12 100 11.125 0.0 3 Mfx 0.0 0.100 120 65.102 to 0.0 0.0 3.462 * * Fixed Loss = 3.462 101 11.125 329.69 3.334 0.0 0.100 0.0700 0.007 Vet = 12.12 101 11.125 0.0 3 0.0 44.417 120 68.571 to 0.0 0.0 0.0 102 11.125 329.69 3.334 0.0 44.417 0.0832 3.697 Vet = 12.12 102 11.125 0.0 3 V 7.496 3.875 120 72.268 to 0.0 7.496 0.0 103 11.125 329.69 3.334 0.0 11.371 0.0833 0.947 Vel= 12.12 103 11.125 0.0 3 0.0 55.958 120 73.215 to 0.0 0.0 0.0 104 11.125 329.69 3.334 0.0 55.958 0.0832 4.658 Vet = 12.12 104 11.125 0.0 3 0.0 23.792 120 77.873 to 0.0 0.0 0.0 134 11.125 329.69 3.334 0.0 23.792 0.0832 1.980 Vet = 12.12 134 11.125 0.0 3 0.0 18.833 120 79.853 to 0.0 0.0 0.0 135 11.125 329.69 3.334 0.0 18.833 0.0833 1.568 Vet = 12.12 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 23 OMWD AREA 3 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 135 11.125 0.0 3 0.0 32.333 120 81.421 to 0.0 0.0 0.0 136 11.125 329.69 3.334 0.0 32.333 0.0832 2.691 Vel= 12.12 136 11.125 0.0 3 V 7.496 24.500 120 84.112 to 0.0 7.496 0.0 TOR 11.125 329.69 3.334 0.0 31.996 0.0832 2.663 Vel = 12.12 TOR 11.125 0.0 4 B 16.724 10.625 120 86.775 to 0.0 16.724 4.602 BOR .500 329.69 4.31 0.0 27.349 0.0238 0.652 Vel = 7.25 BOR .500 0.0 6 L 11.316 12.000 120 92.029 to 0.0 11.316 2.599 UGI -5.500 329.69 6.357 0.0 23.316 0.0036 0.083 Vel = 3.33 UG1 -5.500 0.0 6 2L 23.005 315.000 150 94.711 to SF 44.733 67.738 2.310 DCI -10.833 329.69 5.86 0.0 382.738 0.0035 1.352 Vel = 3.92 DCI -10.833 0.0 6 T 43.037 24.000 140 98.373 to 2E 40.168 83.205 2.740 * * Fixed Loss = 2.74 DC2 -10.833 329.69 6.16 Zaf 0.0 107.205 0.0032 0.338 Vel = 3.55 DC2 -10.833 0.0 6 G 4.304 33.000 140 101.451 to T 43.037 47.341 0.433 HYD -11.833 329.69 6.16 0.0 80.341 0.0031 0.253 Vel = 3.55 HYD -11.833 HIOO 100.00 6 0.0 0.100 140 102.137 to 0.0 0.0 -5.125 SRC 0 429.69 6.16 0.0 0.100 0 0.0 Vel = 4.63 0.0 SRC 429.69 97.012 KFactor= 43.63 Computer Programs by Hydratec Inc. Revision: 50.53.5 Hamilton Fire Protection Page 24 OMWD AREA 4 Date 7/21/19 Hydraulic Design Information Sheet Name - OMWD AREA 4 Date - 7-21-19 Location - 1966 OLIVENHAIN RD ENCINITAS Building - System No. - Contractor - Contract No. - Calculated By - Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 7 FT Occupancy - UNUSED ATTIC SPACE S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E N Area of Sprinkler Operation - 1212 System Type Sprinkler/Nozzle Density - .1 (X) Wet Make TYCO D Area Per Sprinkler - 130 ( ) Dry Model TYFRB E Elevation at Highest Outlet - 14.33 ( ) Deluge Size 1/2 S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 321.6 Press Required - 86.85 BOR Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 5/30/19 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 140 @ Press - R Residual Press - 138 Elev. - Well Flow - 1630 Proof Flow S Elevation - 0 U P Location - 1966 OLIVENHAIN RD P L Source of Information - OMWD Y C Commodity Class Location O Storage Ht. Area Aisle W. N Storage Method: Solid Piled % Palletized % Rack N Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf 0 R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Water Supply Curve C Hamilton Fire Protection Page 25 OMWD AREA 4 Date 7/21/19 City Water Supply: Demand: Cl - Static Pressure : 103 Dl - Elevation : 5.955 C2- Residual Pressure: 100 D2 - System Flow :321.611 C2 - Residual Flow : 1630 D2 - System Pressure : 91.759 Hose ( Demand) : 100 D3 - System Demand :421.611 Safety Margin : 10.995 150 140 130 p120 R° C2 E10° D2 a s 90 80 u 70 R6° E5° 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Hamilton Fire Protection Page 26 OMWD AREA 4 Date 7/21/19 Fitting Legend Abbrev. Name ½ ½ 1 1% 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA I345Elbow I 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 13 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 V 90 Ell Firelock #001 0 0 0 0 0 3.5 4.3 5 0 6.8 8.5 10 13 4.5 5.1 0 0 0 0 0 X 90Tee-BranchFirelockO02 0 0 0 0 0 8.5 10.8 13 0 16 21 25 33 9.3 11 0 0 0 0 0 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Pressure I Flow Summary - STANDARD Hamilton Fire Protection Page 27 OMWD AREA 4 Date 7/21/19 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 105 11.25 5.6 8.52 na 16.34 0.1 130 7.0 106 12.0 5.6 9.21 na 17.0 0.1 130 7.0 107 12.0 5.6 11.51 na 19.0 0.1 130 7.0 108 12.0 5.6 12.93 na 20.14 0.1 130 7.0 109 12.0 5.6 16.05 na 22.43 0.1 130 7.0 110 12.0 16.45 na 111 11.125 19.36 na 112 11.25 5.6 7.51 na 15.35 0.1 130 7.0 113 13.75 5.6 7.0 na 14.82 0.1 130 7.0 114 11.25 5.6 7.94 na 15.78 0.1 130 7.0 115 13.75 5.6 7.45 na 15.29 0.1 130 7.0 116 14.333 9.89 na 117 14.333 5.6 10.62 na 18.25 0.1 130 7.0 118 14.333 11.81 na 119 14.333 5.6 12.17 na 19.54 0.1 130 7.0 120 14.333 5.6 15.53 na 22.07 0.1 130 7.0 121 14.333 16.85 na 122 11.125 19.83 na 123 11.25 5.6 10.55 na 18.19 0.1 130 7.0 124 12.0 5.6 11.47 na 18.97 0.1 130 7.0 125 12.0 5.6 14.28 na 21.16 0.1 130 7.0 126 12.0 5.6 15.58 na 22.1 0.1 130 7.0 127 12.0 5.6 20.23 na 25.19 0.1 130 7.0 128 12.0 20.63 na 129 11.125 24.09 na 130 11.125 25.19 na 131 11.125 41.6 na 132 11.125 49.24 na 133 11.125 66.85 na 134 11.125 75.01 na 135 11.125 76.51 na 136 11.125 79.08 na TOR 11.125 81.63 na BOR 0.5 86.85 na UG1 -5.5 89.53 na DCI -10.833 93.13 na DC2 -10.833 96.21 na HYD -11.833 96.88 na 100.0 SRC 0.0 91.76 na The maximum velocity is 27.07 and it occurs in the pipe between nodes 130 and 131 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 28 OMWD AREA 4 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 105 11.250 5.60 16.34 1 2E 4.672 8.625 120 8.519 to 0.0 4.672 -0.325 106 12 16.34 1.083 0.0 13.297 0.0767 1.020 Vel = 5.69 106 12 5.60 17.00 1 0.0 8.000 120 9.214 to 0.0 0.0 0.0 107 12 33.34 1.083 0.0 8.000 0.2868 2.294 Vel= 11.61 107 12 5.60 19.00 1.25 0.0 8.000 120 11.508 to 0.0 0.0 0.0 108 12 52.34 1.418 0.0 8.000 0.1778 1.422 Vel = 10.63 108 12 5.60 20.14 1.25 T 6.849 4.000 120 12.930 to 0.0 6.849 0.0 110 12 72.48 1.418 0.0 10.849 0.3246 3.522 Vel= 14.72 0.0 110 72.48 16.452 KFactor= 17.87 109 12 5.60 22.43 1.25 1 6.849 4.000 120 16.049 to 0.0 6.849 0.0 110 12 22.43 1.418 0.0 10.849 0.0371 0.403 Vel = 4.56 110 12 72.48 1.5 T 9.123 0.875 120 16.452 to 0.0 9.123 0.379 111 11.125 94.91 1.654 0.0 9.998 0.2526 2.525 Vel= 14.17 111 11.125 0.0 2 0.0 7.500 120 19.356 to 0.0 0.0 0.0 122 11.125 94.91 2.203 0.0 7.500 0.0625 0.469 Vel = 7.99 0.0 122 94.91 19.825 KFactor= 21.32 112 11.250 5.60 15.35 1 0.0 8.333 120 7.514 to 0.0 0.0 -1.083 113 13.750 15.35 1.083 0.0 8.333 0.0683 0.569 Vel = 5.35 113 13.750 5.60 14.82 1 E 2.336 5.000 120 7.000 to 1 5.84 8.176 -0.252 116 14.333 30.17 1.083 0.0 13.176 0.2382 3.139 Vel = 10.51 0.0 116 30.17 9.887 K Factor = 9.59 114 11.250 5.60 15.78 1 0.0 8.333 120 7.938 to 0.0 0.0 -1.083 115 13.750 15.78 1.083 0.0 8.333 0.0719 0.599 Vel = 5.50 115 13.750 5.60 15.29 1 E 2.336 2.500 120 7.454 to T 5.84 8.176 -0.252 116 14.333 31.07 1.083 0.0 10.676 0.2515 2.685 Vel= 10.82 116 14.333 30.16 1.25 0.0 8.083 120 9.887 to 0.0 0.0 0.0 118 14.333 61.23 1.418 0.0 8.083 0.2377 1.921 Vel = 12.44 0.0 118 61.23 11.808 KFactor= 17.82 117 14.333 5.60 18.25 1 E 2.336 4.417 120 10.624 to T 5.84 8.176 0.0 118 14.333 18.25 1.083 0.0 12.593 0.0940 1.184 Vel = 6.36 118 14.333 61.24 1.5 0.0 2.000 120 11.808 to 0.0 0.0 0.0 119 14.333 79.49 1.654 0.0 2.000 0.1820 0.364 Vel = 11.87 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 29 OMWD AREA 4 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 EIev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 119 14.333 5.60 19.53 1.5 T 9.123 8.000 120 12.172 to 0.0 9.123 0.0 121 14.333 99.02 1.654 0.0 17.123 0.2732 4.678 Vet = 14.79 0.0 121 99.02 16.850 KFactor= 24.12 120 14.333 5.60 22.07 1 T 5.84 4.000 120 15.535 to 0.0 5.840 0.0 121 14.333 22.07 1.083 0.0 9.840 0.1336 1.315 Vel= 7.69 121 14.333 99.03 1.5 0.0 0.0 120 16.850 to 0.0 4.000 1.389 122 11.125 121.1 1.654 0.0 4.000 0.3965 1.586 Vel = 18.08 122 11.125 94.91 2 X 11.593 7.125 120 19.825 to 0.0 11.593 0.0 130 11.125 216.01 2.203 0.0 18.718 0.2864 5.361 Vel= 18.18 0.0 130 216.01 25.186 KFactor= 43.04 123 11.250 5.60 18.19 1 2E 4.672 8.625 120 10.553 to 0.0 4.672 -0.325 124 12 18.19 1.083 0.0 13.297 0.0936 1.244 Vel= 6.34 124 12 5.60 18.97 1 0.0 8.000 120 11.472 to 0.0 0.0 0.0 125 12 37.16 1.083 0.0 8.000 0.3504 2.803 Vet = 12.94 125 12 5.60 21.16 1.25 0.0 6.000 120 14.275 to 0.0 0.0 0.0 126 12 58.32 1.418 0.0 6.000 0.2172 1.303 Vet= 11.85 126 12 5.60 22.10 1.25 T 6.849 6.000 120 15.578 to 0.0 6.849 0.0 128 12 80.42 1.418 0.0 12.849 0.3935 5.056 Vel= 16.34 0.0 128 80.42 - 20.634 K Factor= 17.70 127 12 5.60 25.19 1.25 T 6.849 2.000 120 20.227 to 0.0 6.849 0.0 128 12 25.19 1.418 0.0 8.849 0.0460 0.407 Vel = 5.12 128 12 80.41 1.5 T 9.123 0.875 120 20.634 to 0.0 9.123 0.379 129 11.125 105.6 1.654 0.0 9.998 0.3078 3.077 Vet = 15.77 129 11.125 0.0 2 X 11.593 2.792 120 24.090 to 0.0 11.593 0.0 130 11.125 105.6 2.203 0.0 14.385 0.0762 1.096 Vet = 8.89 130 11.125 216.01 2 V 4.774 22.667 120 25.186 to 0.0 4.774 0.0 131 11.125 321.61 2.203 0.0 27.441 0.5980 16.411 Vet = 27.07 131 11.125 0.0 2 V 4.774 8.000 120 41.597 to 0.0 4.774 0.0 132 11.125 321.61 2.203 0.0 12.774 0.5980 7.639 Vet = 27.07 132 11.125 0.0 2 0.0 29.458 120 49.236 to 0.0 0.0 0.0 133 11.125 321.61 2.203 0.0 29.458 0.5980 17.617 Vet = 27.07 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations: Hazen-Williams Hamilton Fire Protection Page 30 OMWD AREA 4 Date 7/21/19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 133 11.125 0.0 2.5 0.0 37.083 120 66.853 to 0.0 0.0 0.0 134 11.125 321.61 2.705 0.0 37.083 0.2201 8.161 Vet = 17.95 134 11.125 0.0 3 0.0 18.833 120 75.014 to 0.0 0.0 0.0 135 11.125 321.61 3.334 0.0 18.833 0.0795 1.498 Vet = 11.82 135 11.125 0.0 3 0.0 32.333 120 76.512 to 0.0 0.0 0.0 136 11.125 321.61 3.334 0.0 32.333 0.0795 2.570 Vet = 11.82 136 11.125 0.0 3 V 7.496 24.500 120 79.082 to 0.0 7.496 0.0 TOR 11.125 321.61 3.334 0.0 31.996 0.0795 2.544 Vet = 11.82 TOR 11.125 0.0 4 B 16.724 10.625 120 81.626 to 0.0 16.724 4.602 BOR .500 321.61 4.31 0.0 27.349 0.0227 0.622 Vet = 7.07 BOR .500 0.0 6 L 11.316 12.000 120 86.850 to 0.0 11.316 2.599 UG1 -5.500 321.61 6.357 0.0 23.316 0.0034 0.080 Vet = 3.25 UGI -5.500 0.0 6 2L 23.005 315.000 150 89.529 to 5F 44.733 67.738 2.310 DC1 -10.833 321.61 5.86 0.0 382.738 0.0034 1.291 Vet = 3.83 DCI -10.833 0.0 6 T 43.037 24.000 140 93.130 to 2E 40.168 83.205 2.756 * * Fixed Loss = 2.756 DC2 -10.833 321.61 6.16 Zaf 0.0 107.205 0.0030 0.322 Vet = 3.46 DC2 -10.833 0.0 6 G 4.304 33.000 140 96.208 to T 43.037 47.341 0.433 HYD -11.833 321.61 6.16 0.0 80.341 0.0030 0.242 Vet = 3.46 HYD -11.833 HIOO 100.00 6 0.0 0.100 140 96.883 to 0.0 0.0 -5.125 SRC 0 421.61 6.16 0.0 0.100 0.0100 0.001 Vet = 4.54 0.0 SRC 421.61 91.759 KFactor= 44.01 Computer Programs by Hydratec Inc. Revision: 50.53.5 FFC,2019 - 014:~ SSM/SSV Series Alarm Bells System Sensors SSM and SSV series alarm bells are low current, high decibel notification appliances for use in fire and burglary systems or other signaling applications. Features Approved for indoor and outdoor use Low current draw High dB output Available in six-inch, eight-inch, and ten-inch sizes AC and DC models DC models polarized for use with supervision circuitry Mount directly to standard four-inch square electrical box indoors SSM and SSV series come pre-wired Reliable Performance. The SSM and SSV series provide loud resonant tones. The SSM series operates on 24VDC and are motor driven, while the SSV series operates on 120VAC utilizing a vibrating mechanism. Simplified Installation. For indoor use, the SSM and SSV series mount to a standard four-inch square electrical box. For outdoor applications, weatherproof back box, model number WBB, is used. The SSM and SSV series come pre-wired, to reduce installation time. The SSM series incorporates a polarized electrical design for use with supervision circuitry. Agency Listings LISTED A"RO~D S401 CS549 3005255 7135-16530125 FPC20I9..0177 1966 OLIVENHAIN RD OLIVENHAIN MWD - NEW SYSTEM WTH POC @ BASE OF RISE (646 HEADS) DEV02001 2550310300 8/22/2019 FPC20I9-0177 SSM/SSV Specifications Model shall be a SSM or SSV Series alarm bell. Bells shall have underdome strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 678710"(specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi-flush mounting. Outdoor surface mounted installations shall be weatherproof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4" square electrical box having a maximum projection of 21/2'l Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction. Bells shall be listed for indoor/outdoor use by Underwriters Laboratories and the California State Fire Marshal, and approved by Factory Mutual and MEA. Operating Temperature Range —31°F to 140°F Operating Voltage SSM series: 24 VDC SSV series: 120 VAC Termination Provided with 2 sets of leads for in/out wiring Service Use Fire Alarm, General Signaling, Burglar Alarm Warranty 3 years Model Gong Diameter (inches) Nominal Voltage Operating Voltage Limit Maximum Current Sound Output (dBA) SSM24-6 6 Regulated 24VDC 16 to 33VDC DC-31.1mN FWR-53.5mA 82 SSM24-8 8 Regulated 24VDC 16 to 33V00 DC-31.1 mA/ F\NR-53,5mA 80 SSM24-1 0 10 Regulated 24VDC 16 to 33VDC DC-31 .1 mAt FWR-53.5mA 81 SSV120-6 6 Regulated 120VAC 96 to 132VAC 53mA 85 SSV120-8 8 Regulated 120VAC 96 to 132VAC 53mA 82 SSV120-10 10 Regulated 120VAC 96to132VAC 53mA 82 Sound output measured at Underwriter Laboratories, as specified in UL464 Ordering Information SSM24-6 SSM24-6A Bell, 6-, 24VDC, Polarized, 82dBA SSM24-8 SSM24-8A Bell, 8' 24VDC, Polarized, 8OdBA SSM24-10 SSM24-10A Bell, 10' 24VDC, Polarized, 81dBA SSV120-6 SSV120-6A Bell, 6 12OVAC, 85dBA SSV120-8 SSV120-8A Bell, 8' 120VAC, 82dBA SSV120-10 SSV120-10A Bell, 10' 120VAC, 82dBA WBB Weatherproof back box for SSM and SSV series, when installed outdoors T" 15vs'7E, 3825 Ohio Avenue • St. Charles, IL 60174 2012 System Sensor. for current product information, including the latest version at this data sheet Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change Without notice, Visit systernsensor,com www.systemsensor.com VIS74501 • 3/12 FireLock® Butterfly Valve A -C —ta —U1 i C r Series 705 with Weatherproof Actuator 10.81 1.0 PRODUCT DESCRIPTION Available Sizes: 2 - 12/50 - 300 mm cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa /20 bar. Designed for fire protection services only. Features a weatherproof actuator housing Approved for indoor and outdoor use. Actuation options: Hand wheel (2 - 12/50 - 300 mm) Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS c®us USThO 0410001 104j/04 NOTES Refer to Victaulic submittal publication 10.01 for details ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. I Location Submitted By Date Spec Section Paragraph Approved Date vh-+.qidir mm 10.81 5662 Rev H updated 03/2017 0 2017 Victaulic Company. All rights reserved. 1 \4taulic victaulic.com 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve cULus FM Vds LPCB Size 50 up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa . 2,5 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm upto300psi/2O68kPa up to 300psi/2068kPa upt0300psi/2O68kPa up to 300psi/2068kPa 80 up to 300psi/2068kPa up to 300ps1/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 100 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 125 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 3000si/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 1 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 16.5 .1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 250 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 300 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS - MATERIAL Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 - 6"/50 - 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 - 12"/200 - 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade "E" EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TEE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: O 2-8/50-200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing El 10— 12/250 - 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 10.81 5662 Rev H updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 2 \jtauIic victaulic.com 4.0 DIMENSIONS Series 705 Size Actual Dimensions Outside E to E DIA Nominal Diameter A B C D E F G H J inches inches inches inches inches inches inches inches inches inches inches Mm :2375 mm mm 4.25 mm 2.28 mm 6.41 mm mm mm 40 mm :42 mm 45 mm 603 603 1080 579 1628 1016 1072 1143 538 21/2 73 2.875 73.0 3.77 95.8 2.28 57.9 7.54 191.5 - - 4.00 101.6 4.22 107.2 4.50 114.3 1.77 45.0 761 mm 3000 761 377 958 228 579 754 1915 - - I 400 1016 422 1072 450 1143 177 450 3 88.9 3.500 88.9 3.77 95.8 2.53 64.3 7.79 197.9 - - 4.50 114.3 4.22 107.2 4.50 114.3 1.77 45.0 108 mm 4 4.250 1080 4.500 463 1176 4.63 288 732 2.88 881 2238 8.81 - - 550 1397 5.50 422 1072 4.22 450 1143 4.50 1 220 559 2.20 114.3 114.3 117.6 73.2 223.8 - 139.7 107.2 114.3 55.9 133 mm 5.250 588 335 1088 - - 656 619 630 258 1397 mm 1330 5.500 1494 5.88 851 3.35 2764 10.88 j - - 1666 6.56 1572 6.19 1600 6.30 655 2.58 5 139.7 5.563 149.4 588 85.1 335 276.4 1088 166.6 656 157.2 619 160.0 630 65.6 258 1413 1413 1494 851 2764 - 1666 1572 1600 655 mm 159 6.250 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 1651 mm 6 168.3 159.0 6500 1651 6.625 168.3 149.4 588 1494 5.88 149.4 97.5 384 975 3.84 97.5 289.1 1138 2891 11.38 289.1 - - 10.4 041 104 0.41 10.4 191.0 752 1910 7.52 191.0 157.2 619 157.2 6.19 157.2 j 160.0 630 1600 6.30 160.0 65.5 258 655 1.90 48.3 8 8625 533 507 1353 080 147 1000 619 810 233 2191 10 273 2191 10.750 273.0 1354 6.40 162.6 1288 6.37 161.8 3436 15.64 397.3 203 1.41 35.8 373 1.81 46.0 2540 12.25 311.2 1572 8.10 205.7 1 2057 9.00 228.6 592 - 12 12.750 650 736 1664 230 280 I 1425 810 900 323 9 [39 7 584 J20 205.7 2286 - NOTE Optional ½/lb mm tap available. Contact Victaulic for details. 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 3 \,sltauIic victaulic.cnm 5.0 PERFORMANCE Series 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size mm Diameter mm Feet/rn inches 2 inches 2.375 of pipe 6 50 603 18 2½ 2.875 6 65 73.0 1.8 76.1 mm 3.000 168 76.1 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108mm 108 mm 2.4 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm 6.500 14 4.2 8 8.625 16 200 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victhulic.com 4 4tauiicr victaulic.com p 5.1 PERFORMANCE Series 705 Cv values for flow of water at +60°F/-i-160C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C, values Formulas for K5 values AP = Where: AID = Q2 Q = Flow (GPM) AP = Pressure Drop (psi) 0 = C x J2i C= Flow Coefficient Q = K Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches mm 2 50 mm 2.375 170 2/2 65 2.875 73.0 260 76.1 mm 3.000 76.1 260 3 80 3.500 88.9 440 4 4.500 fl4.3 820 108 mm I 108mm 820 5 5.563 1200 125 133mm 141.3 I 133mm 1200 139.7mm 12.00, 35 9.7 6 150 159 mm 6.625 168.3 159mm 1800 1800 165.1 mm 165.1 6.500 1800 8 8.625 200 219.1 3400 10 250 12 3 00 10.750 273.0 i 12.750 323.9 5800 j 9000 Where: o = Flow (m3/hr) AP = Pressure Drop (Bar) K =Flow Coefficient Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches mm inches mm 2 50 2.375 1 147 60.3 2'/2 2.875 65 22 73.0 76.1 mm 3.000 225 76.1 3 3.500 380 80 88.9 4 4.500 100 114.3 710 108 mm 108 mm 710 5 125 5.563 141.3 1040 133mm 133mm 1040 139.7mm 5.500 i 13 1040 6 6.625 150 168.3 1560 159 mm 159 mm 1560 165.1 mm 6 500 165.1 1560 8 8.625 2940 200 219.1 10 10.750 5020 250 273.0 12 12.750 7790 300 323.9 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 5 \JtiUliC victaulic.com 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring The supervisory switch contains two single pole, double throw, pre-wired switches. UL LISTED JUNCTION BOX Switches are rated: CONDUIT 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps © 125 VDC 11 CONDUIT CONNCCTORS 0.25 amps @ 250 VDC WIRO NUTS Switches supervise the valve in the "OPEN" position. 5. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer FIRE ALARM LPANEL TO END-OF-UNE RESISTOR, OR NEXT INDICATOR SUPERVISORY to diagrams and notes below). The second switch CIRCUIT has one #18 insulated wire per terminal. This double CONTRO To circuit provides flexibility to operate two electrical IT SWITCH CONTACT RATING: L......J devices at separate locations, such as an indicating 1OAAI12SAND 2SOVAC, SI light and an audible alarm, in the area that the valve 0. SA AT 125 VEX o.2SAT2SavX ________ I BELL is installed. • ceKI VOLTAGE SOURCE _______ RN HOflJ 6. A #14 insulated ground lead (green) is provided. SWIBEI, 1 2 lead, per terminal Switch #1 = Si Switch 21 lead per terminal For connection to the supervisory circuit of a UL Listed alarm control panel NOTES The above diagram shows a connection between the common terminal Switch #2 = S2 (yellow - Si and yellow-with-orange stripe.- S2) and the normally closed Auxiliary switch that may be connected to auxiliary terminal (blue - Si and blue-with-orange stripe -S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When devices, per the authority having jurisdiction the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e.g. brown with orange stripe). Normally Closed: (2) Blue • Only Si (two leads per terminal) may be connected to the fire alarm Si Common: (2) Yellow control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. ,,it4.itlir mm \4taulicr victaulic.com 7.1 REFERENCE MATERIALS 10.01: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty 1-100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building cedes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/sr methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POE format on our website at www.victaelic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.81 5662 Rev H Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 7 \tauIic F P P Description FPPI 's Sprinkler Gauge Kits provide everything needed to install a fire sprinkler gauge to a riser or other device. Each kit contains a pressure gauge that is UL Listed and FM approved for Fire Sprinkler Service, ¼" brass 3-way valve (UL! ULc Listed), 1/4" x ½" galvanized reducer, ¼" (PS x 4" galvanized pipe nipple and a ¼" (PS galvanized plug. Each kit is shrink wrapped to a sturdy cardboard backing to prevent the loss of the components before being installed at the job site. Available with Water, Air-Water, Air or Air with Retard fire gauge. Specifications 11-565 Pressure Gauge Kit, Water 11-566 Pressure Gauge Kit, Air-Water 11-567 Pressure Gauge Kit, Air 11-568 Pressure Gauge Kit, Air w/Retard 11-569-00 Gauge Kit, Air- Water, Personalized The information contained herein is produced in good faith and is believed to be reliable but is provided for guidance and information purposes only. FPPI and its agents cannot assume liability or responsibility for results obtained in the use or misuse of its product by persons whose methods and qualifications are outside and beyond our control. It is the user's responsibility to determine the suitability of, methods of use, preparation prior to use, and appropriate installation for all products purchased from FPPI. It is the user's sole responsibility to observe and adapt such precautions as may be advisable or necessary for the protection of personnel and property in the handling and use of any of our products. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 +1(760)599-1168 + 1 (800) 344-1822 + 1(800) 344-3775 FAX © 2016 Fire Protection Products, Inc. !IS]11.1 WFDN Series Waterfiow Detector The System Sensor WFDN series is compatible with schedule 7 through 40 steel pipe, for sizes 2 in. through 4 in. and compatible with schedule 10 through 40 steel pipe, sizes 5 in. through 8 in., and can be mounted in a vertical or horizontal position. Features New directional cover allows installers and inspectors to easily see the direction of flow UL-listed models are NEMA 4 rated New cover provides a better seal, is lighter weight, not painted and corrosion resistant Sealed retard mechanism immune to dust and other contaminants Less exposed metal reduces shock hazard, plastic cover acts as insulator and is resistant to arcing Visual switch activation Audible switch activation (73 dBA) Field-replaceable timer/switch assembly Accommodates up to 12 AWG wire Switch Synchronization activates both alarm panel and local bell or horn strobe Tamper-resistant cover screws Improved water sealing Reduced product weight Wire-ready terminals Improved wiring with new terminal block layout Snap-in optional cover tamper switch Improved timer repeatability and accuracy Agency Listings C®US Ô; 4j LISTED APPROVED S739 7770-1653:0231 3051266 The new WFDN Series waterf low detectors from System Sensor consists of a rugged, NEMA 4-rated enclosure that is more damage resistant than previous metal designs. The waterf low detector is designed for both indoor and outdoor use, with the widest available temperature range, from 32°F to 150°F. They are also approved for installation on the widest range of pipe schedules, sizes 2 in. through 4 in. are approved for installation on pipe schedules 7 through 40. UL-listed models are equipped with tamper-resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block with new layout designed to make wiring easy with wire ready terminals, COM terminals are on a different elevation, large barrier between switches and easy to read raised textured lettering all make wiring easy. An optional cover tamper switch is available, securely snaps into place, no tools required. The WFDN series incorporates a mechanical time delay feature, which minimizes the risk of false alarm due to pressure surges or air trapped in the fire sprinkler system. The larger and easy to turn timer dial makes setting the waterf low detector easy with high contrast pad printed markings. The dial offers three tabs to help with turning, with one larger tab located on the dial position for approximately 60 seconds, a notch is also indicated on the dial to locate approximately 30 seconds making setting the detector in dimmly lit locations easy. The WFDN series is designed for accuracy and repeatability. The detector also offers improved performance during vibration in riser applications where detectors are exposed to a large in rush of water. Li Waterfiow Detector Specifications Vane-type waterf low detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6 in. from any fittings that may change water direction, flow rate, or pipe diameter or no closer than 24 in. from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi for 2 in. -8 in. pipes. The detector shall respond to waterf low in the specified direction after a preset time delay that is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual and audible indication of actuation. The actuation mechanism shall include a ethylene vinyl acetate vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or outdoor use. I Static Pressure Rating 450 PSI Operating Temperature Range 32°F to 150°F (0°C to 66°C) Maximum Surge 18 Feet Per Second (FPS) Enclosure Rating* NEMA 4-suitable for indoor/outdoor use Triggering Threshold 4-10 GPM Cover Tamper Switch Standard with ULC models, optional for Bandwidth (Flow Rate) UL models, part no. CIS Conduit Entrances Two openings for 1/2 in. conduit. Service Use Automatic Sprinkler: NFPA-13 NEMA 4 rated plugs One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA-72 Contact Ratings Two sets of SPDT (Form C) Warranty 3 Years 10.0 A, ½ HP @ 125/250 VAC 2.5 A @6/12/24 VDC Compatible Pipe Steel water pipe, schedule 7 throuoh 40* WFDN Field Wiring Diagram Overall Dimensions, Installed SSM24-X I SSV12S.X k ) NOTIT COMMON AND B.NO \,, ,/ CONNECTIONS WILL CLOSE 5A-IEN VANE IS DEFLECTED I.E., WHEN WATER IS FLOWING. DUAL SWITCHES PERMIT APPLICA11ONS TO BE COMBINED ON A SINGLE DEFECTOR. SCHEMATIC OF ABC INDIVIDUAL SWITCH IN COM NOWATERFLO W CONDITION A I I N-NO BREWS WIRE AS SHOWN FOR SUPERVISION OF CONNECTION. SO © NOT ALLOW STRIPPES WIRE LEADS TO EXTEND BEYOND SWITCH HOUSING. DO NOT READY STATE • LOOP WIRES. VAULT NI APR SADDLE SRI 0WRALLBIDTh = PIPE DIAMETER* R.4CMIOSI UL-LISTED COMPATIBLE CONTROL PANEL POWER 24V5C OR I2OVAC INITIATING + a SUGGESTED EOL [- RESISTOR LOOP CONTACT RATINGS 125/250VAC ISAMPS 24VDC 2.5 AMPS _ UL Model ULC Model Pipe Size Hole Size Shipping Weights WFD20N WFD20NA 2 in. 11/4 in. 2.6 lbs. WFD25N WFD25NA 21/2 in. 11/4 in. 2.6 lbs. WFD30N WFD30NA 3 in. 2 in. 3.1 lbs. WFD40N WFD40NA 4 in. 2 in. 4.0 lbs. WFD50N WFD50NA 5 in. 2 in. 4.9 lbs. WFD60N WFD60NA 6 in. 2 in. 5.6 lbs. WFD80N WFD80NA 8 in. 2 in. 7.3 lbs. Accessories FS-RT Delay mechanism and switch assembly CIS Tamper-proof switch kit WFDW Tamper-proof wrench for cover A 2 in. -4 in. rated for use with Schedule 7 through 40 pipe, 6 in, -8 in. rated for use with Schedule 10 through 40 pipe. \ 5"f5 7J4 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 5ENSOR for www.systemsensor.com . 02016 System Sensor. PISUUCI spRCcflcasce1s subject to change Without notice. Visit sySternsenSor.Cocn current product Information, including The latest version of This data sheet. Wu-DS87903 • IT/TA Victaulic® Flexible Coupling ill, 1. Aic- -te -U1 i C r Style 75 06.05 _ I:VAi].]Kl.I. etilI. 1.0 PRODUCT DESCRIPTION Available Sizes 1 - 87DN25 - DN200 Pipe Material Carbon steel Stainless steel Maximum Working Pressure Accommodates pressures ranging from full vacuum (29.9 in Hg/760 mm Hg) up to 500 psi/3447 kPaI34 bar Working pressure dependent on material, wall thickness and size of pipe Application Joins standard roll grooved and cut grooved pipe, as well as grooved fittings, valves and accessories Provides a flexible pipe joint which allows for expansion, contraction and deflection Up to 50% lighter in weight than standard Victaulic Style 77 or Style 177N flexible couplings 2.0 CERTIFICATION/LISTINGS cu$&Tin NOTES Download publication 10.01 for Fire Protection Certifications/Listings Reference Guide. See oubhcatipn 02.06: Victaulic Potable Water Approvals ANSI/NSF for potable water approvals if applicable. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. [Location Spec Section paragraph Submitted By J Date Approved Date victaulic.com 06.05 1470 Rev P updated 10/2017 © 2017 Victaulic Company. All rights reserved. 1 Atc—t—sulic victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-4542. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) El Standard: Orange enamel 0 Optional: Hot dipped galvanized 0 Optional: Contact Victaulic with your requirements for other coatings. Gasket: (specify choice') El Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30°F to +230°F/-34°C to +110°C. May be specified for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot +180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR USE WITH PETROLEUM SERVICES OR STEAM SERVICES. Grade "T" Nitrile Nitrile (Orange stripe color code). Temperature range —20°F to +180°F/-290C to +82°C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; not compatible for hot dry air over +140°F/+60°C and water over +150°F/+66°C. NOT COMPATIBLE FOR USE WITH HOT WATER. 0 Others For alternate gasket selection, reference publication 05.01: Victaulic Seal Selection Guide - Elastomeric Seal Construction. Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: (specify choice2) E] Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - heavy hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex nuts are zinc electroplated per ASTM B633 ZN/FE5, finish Type Ill (imperial) or Type II (metric). Optional (imperial): Stainless steel oval neck track bolts meeting the mechanical property requirements of ASTM F593, Group 2 (316 stainless steel), condition CW. Stainless steel heavy nuts meeting the mechanical property requirements of ASTM F594, Group 2 (316 stainless steel), condition CW, with galling reducing coating. 2 Optional bolts/nuts are available in imperial sizes only. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 2 ltauIîcr victaulic.com 4.0 DIMENSIONS Style 75 too I I, iiI 'm__•' Il Pipe End Deflection from Size Separation3 Centerline3 Bolt/Nut Dimensions Weight Actual Outside Approx. Nominal Diameter Allowable Per Cplg. Pipe Qty. Size X Y Z (Each) inches inches inches inches/ft. imperial inches inches inches lb DN mm mm Degrees mm/m - metric mm mm mm kg 1 1.315 0-0.06 0.57 %x2 2.38 4.27. 1.77 1.3 DN25 33.7 0-1.6 21-43' 48 2 M10x51 61 108 45 0.6 1 1/4 1.660 0-0.06 0.45 ~x2 2.68 4.61 1.77 1.4 DN32 42.4 0-1.6 21 - 10' 38 2 M10x51 68 117 45 0.6 1½ 1.900 0-006 040 %x2 291 482 177 15 DN40 48.3 0-1.6 1 -56 - 2 M10x51 74 122 45 0.6 2 2.375 0-0.06 0.32 %x2 3.43 5.22 1.88 1.7 DN50 60.3 0-1.6 11 - 31' 26 2 - M10xS1 87 133 J 48 0.8 2 1/2 2.875 0-006 026 ~x2 388 568 188 19 73.0 0-1.6 1 - 1 22 2 * M10x51 98 144 48 0.9 3.000 0-0.06 1° -12' 0.26 2 ~x2 4.00 5.90 1.88 1.9 DN65 76.1 0-1.6 22 - M10x51 102 150 48 0.9 3 3500 0-006 1-2' 022 2 ½x2 a/4 450 700 188 29 DN80 88.9 0-1.6 18 - M12x70 114 178 48 1.3 31/2 4.000 0-0.06 , 0.19 2 ½x21/4 5.00 7.50 1.88 2.9 DN90 101.6 0-1.6 16 - M12x70 127 191 48 1.3 4 4.500 0-013 034 ½x2~ 580 803 213 41 DN100 1143 0-32 10 - 36 28 2 M1200 147 204 54 19 4.250 0-0.13 0.35 ½x2~ 5.55 7.79 2.13 3.7 108.0 0-3.2 - 1° 41' 29 2 M12x70 141 198 54 1.7 5.000 0-013 025 5/a x31/4 613 943 213 55 1270 0-32 1 -26 21 2 M16x83 156 240 54 25 5 5.563 0-0.13 0.27 5/eX3 ¼ 6.88 10.07 2.13 5.8 141.3 0-3.2 11 - 18' 23 2 M16x83 175 256 54 2.6 5.250 0-013 1 21' 028 2 5/a X31/4 655 937 213 60 133.0 0-3.2 *24 M16x83 166 238. 54 2.7 5.500 0-0.13 0.28 /ex3V4 6.80 9.59 2.13 6.3 0N125 139.7 0-3.2 11-18, 24 2 M16x83 173 244 54 2.9 6.000 0-0.13 1- 12' 0.21 2 5/8 X3 ¼ 7.38 10.48 1.88 6.2 152.4 0-3.2 18 M16x83 187 266 48 2.8 6 6.625 0-0.13 I , 1 0.23 2 % x 3¼ 8.00 11.07 2.13 7.0 DN1S0 168.3 0-3.2 .i 18 - M16x83 203 281 54 3.2 6.250 0-0.13 19, 0.24 2 ~ /4 X3' 7.63 10.49 2.13 6.8 159.0 0-3.2 20 - M16x83 194 266 54 3.1 6.500 0-0.13 0.23 ~x3 ¼ 7.84 10.66 2.08 6.6 165.1 0-3.2 17, 58 2 M16x83 199 271 53 3.0 8.515 0-0.13 0 1 0.18 2 ~ /4 X4' 10.19 13.75 2.32 13.2 216.3 0-3.2 . 46 M20 108 259 . 350 . 59 6.0 8 8.625 0-0.13 0.18 3/4x4¼ 10.34 13.97 2.13 12.4 DN200 219.1 0-3.2 0-so, 14 2 M20 108 263_J_ 355 59 5.6 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 114 -3 ½/DN20 - DN90; 25% for 4/DN100 and larger. NOTE Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. I 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 3 victaulic.com 5.0 PERFORMANCE Style 75 Size_____________ Maximum Actual Outside Working Maximum Nominal Diameter Pressure4 End Load4 inches inches psi lb DIN mm kPa N 1 1.315 500 680 DN25 33.7 3447 3,025 11/4 1.660 500 1080 0N32 42.4 3447 4,805 1½ 1.900 500 1420 DN40 48.3 3447 6,320 2 2.375 500 2215 DN50 60.3 3447 9,860 21/2 2.875 500 3245 730 3447 14,440 3.000 500 3535 0N65 76.1 3447 - 15,730 3 3.500 500 4800 - DN80 88.9 - 3447 21,360 3 1/2 4.000 500 6300 DN90 101.6 34.47 28,035 4 4.500 500 7950 DN100 114.3 3447 35,380 4.250 450 6380 108.0 3103 28,395 5.000 450 8820 127.0. 3103 .: _39,250 5 5.563 450 10935 141.3 3103 48,660 5.2S0 450 9735 133.0 3103 43,325 5.500 450 10665 DN125 139.7 3103 47,460 6.000 450 12735 152.4 3103 56,670 6 6.625 450 15525 DN150 168.3 3103 69,085 6.250 450 13800 159.0 3103 61,405 I 6.500 450 14930 165.1 3103 66,412 * 8.515 450 25625 216.3 .3103 113,986 8 8.625 450 26280 DN200 219.1 3103 116,945 -- Working Pressure and End Loud are total, from all internal and external loads, based on ANSI 036.10 sized carbon steel pipe, grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. NOTE WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11h times the figures shown. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com lice victhulic.com 6.0 NOTIFICATIONS WARNING Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICE Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. 7.0 REFERENCE MATERIALS 02.06: Victaulic® Potable Water Approvals ANSI/NSF 05.01: Victaulic® Seal Selection Guide - Elastomeric Seal Construction 06.15: Victaulic® Pressure Ratings and End Loads for Victaulic Couplings on Steel Pjo 10.01: Victaulic® Products for Fire Protection Pipings Systems - Regulatory Approval Reference Guide 17.01 Victaulic® Pipe Preparation for Use on Stainless Steel Pipe With Victaulic Products 1709: Victaulic® Ductile Iron Grooved Couplings Performance Data for Stainless Steel Pipe 26.01: Victaulic® Standard Groove Specifications 26.01: Victaulic® Design Data 29.01: Victaulic® Terms and Conditions of Sale 1100: Victaulic® Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions, Nothing in this or any ether document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, nary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights Na statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any at its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or ether intellectual properly right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products tube installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POF format on our website at www.nictautic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 06.05 1470 Rev P Updated 10/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 'jltauIic Innovative design eliminates Loose hardware, simplifying installation Serrated flange-head bolts eliminate need for wrenches on both bolt and nut Short ears allow for use in spaces where full-sized risers do not fit Conforms with Federal Specification WW-H-171 (Type 81, Manufacturers Standardization Society (MSS( SP-58 (Type 81 Il-s. s 6. Part Number 5120600E0 Material Steel Finish Electrogalvanized Pipe Size 6 Outer Diameter (001 6 5/8' Hole Size INS! 9/16' A 145/16' B 2" Static Load (F) 1,570 lb Certifications cULus Standard Packaging Quantity 10 pc UPC 178285661610 UL, UR, cuL, cUR, cULus and cURus are registered certification marks of UL LLc. WARNING nVent products shall be installed and used only as indicated in oVent's product instruction sheets and training materials. Instruction sheets are available at ww,erico.corn and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent 's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2019 nVent All rights reserved nVent, nVent CADDY, Went ERICO, nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice. nnt CADOY ffc,2-1()1 9 O i -- Hamilton Fire Protection,, Inc. 25060 Hancock Ave., Suite 103 Murrieta, CA 92562 Phone (951) 834-6305 Fax (951) 848-0966 License# 883855 I C-16 Material Cut Sheet Submittal for Olivenhain Municipal Water District 1966 Olivenhain Rd. Encinitas, CA 92024 Date: 7-30-19 By:MH ISNO AlPcArEe i" L.'.4,. *1 z 4/9/2014 Print -- Mafleable iron Screwed Fittings - Class 150 flimliftal Size Dimension A Appox. Wt. Enth k ,i. 1=3 0.69 0.06 0.81 0,10 095 112 1.31 a.22 0.36 150 051 1$ 0. 1,94 116 2 2.25 1.81 21 3'73 3.08 4.82 '1 379 841 6 13 19.96 Dimensional: Fittings: ASME 816.3 Unions: ASME B 1639 Bushings/Plugs: ASME B16.14 Material- ASTM A-i 97 Galvanizing: ASTM.A-153 (Hot Dip Galvanizing) Threading; ASME 13I.20.1 Pressure Rain: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME 816.14 Pressure lesthig: All malleable iron fiffings ore tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions are UL Listed and FM Approved. British Skudwd thfebdijig per 3S 21 avoiiablo upon coqucst httpJ/wi.anAIinll.comfProductSearchlPrintProduct.aspx?iid=4370 112 419/2014 Print CF/PMV1 Malleable Iran Screwed Fittings — Class 150 Nominal Sue --;;TT-;- REDUCING 90' ELBOW F- Uiiiinsions Approx. Wt. Each --- -- / 076 008 0.81 0,85 0.11 088 090 013 'A x 097 098 016 104 103 019 no 112 113 026 10 122 029 118 1i6 035 I ______________ 176 1 ________________________ 1.116 _______________________ 042 ________________________ 1 x 1.37 .45 0.47 1 t 1/4t 134 145 153 1.62 05 02 1 1.58 0.73 1x ii 138 165 065 1.52 ITS 0,74 1.65 180 088 1.82 1.88 1.3 2 1.50 1.89 0.93 1.0 1.97 1.04 20 T 1,73 7.02 1.28 10 210 136 I 'I IL 1 ,.:I:... ttsm '';': n't.' .,s :• - -,-,--. CJI3I ,U Dimensional: Fittings: ASME 8163 Unions- ASME 131&39 Bushings/Plugs: ASME B1614 Material: ASIM A-197 Galvanizing: ASTM A-153 o1 Dp Galvanizing) Threading*: ASME B1.20.1 Pressure Rating: Fittings: ASME B1&3 Unions: ASME 816.39 ,shings/Pkigs: ASME 316.14 Pressure Testing: All malleable iron fittirs are tested for through wall porosity using on air under water process. Agency Approvals; All malleable iron fittings and unions ore UL listed and FM Approved. British Sn1dord throodiog per BS 21 avbkbic upon request REDUCING Dimensions orntnuJ Size A Approx, Wt. Each . . . 10, (Aml Mal t4d 2l½ 2t 2.51 220 IIH 55 3S 3x74 2.83 2.99 4.12 4 x 2 2,72 143 5.01 1'Il I L!1 I LL http:/Mw,.aniIintt.coni/ProductSearthIPrintProduct.asp(?Iid=4371 1/2 4/9/2014 Print Malleable Iron Screwed Fittings - Class 150 $11b APPROVED L-Wwz J t1 a flnna1 Size 1' STRAIGHT TEE Dinierision A Approx. WI. E&h A (i) (?. IY?) 1b.. (k& 0.69 0.09 0.81 014 095 0.21 1.12 0.31 !.3i. 1 10 09 1.7 14. 194 1.5/ 2 'US 2.43 27O 4.33 3 3.08 6.37 4 3,19 ft03 6 5.13 2S98 7-MATERIAL SPECIFICATIONS Dimensional: Fifflngs ASME 8 1&.3 Unions: ASME B16,39 Bushngs/Plugs ASME 816.14 Material: ASIM A- i 97 Galvanizing: ASTM A-153 (Hot-Dip Galvanizing] Threading*: ASME BI.20.1 Pressure Rating: Fillings: ASME Bi&3 Unions ASME B 16.39 Buhing/PIug: ASME 316.14 Pressure testing: All nialleoble iron fillings are tested for through wall porosity using an air underwater process. Agency Approvals: All malleable iron Fittings and unions are U1 listed and EM Approved. British Slonderd threading p& 9S 21 availobto upon fecivosP http:/Mw.arMIintLcomProductSearchlPrintProdUCt.aSp)?Iid4381 1/2 419/2014 Print F/F%N) Malleable Iron Screwed Fittings - Class 150 4 US1D APPROVED ef F LMi&G ,4iM REDUCING tTEE Nominal -ze -i Approx. A B € 1 Wt. (rr,Q (it. (ntt i. tnwi} k (itwtj thi (ta) 0.97 091 0.93 0.24 1.04 1.04 1.03 0.27 122 122 120 031 - I 1.36 136 126 AO o 1.17 I 1.22 0.38 S 105 0.314 1 111 117 113 039 120 20 1 127 043 145 145 31 1, 067 - - i T TTfl 083 £ 141 12 1,45 0.56 1 1.50 16 130 67 1.28 1.20 !; 131 131 i.45 081 150 145 1 150 011 'L1 1.27 1157 77 TIT or 1J7 14 069 1 l 147 167 158 09 1.8 1.813 I 1.65 3.01 I http://wM.anthntI .con'ilProductSearchlPrintProductasp(?Iid=4380 L MATERIAL SPECIFICATIONS Dimensional: Fittings : ASME 816.3 Unions: ASME B16.39 Bushings/Plugs; ASME 916,14 Material: ASTM A-.l 97 Galvanizing: ASTM A- 353 (Hot Dip Galvanizing) Threodin *: ASME 31.20.I Pressure Rating. Fittings. ASME 816.3 Unions: ASME 8139 Bushings/Plugs: ASME 81.6.14 Pressure Testing: All malleable iron littngs ore tested for through wall porosily using on air under woter process. Agency Approvals: All malleable iron linings and unions are Ut Listed and FM Approved. British Standa rd threading per B5 21 ovoikible upon request REDUCING TEE . Uominal Se fliinensions _______ Appox. Wt. Each A C (i, fmd h t?P4J lit. (tmit ._Ths. (kI 1 1.58 1.16 147 0.02 14 1 1.7 1.53 1.75 Q.95 45 131 162 015 ~14 1 153 145 167 097 l 1/5 1 t62 175 100 1,34 1,26 153 -v-- i -nr T -r- f2- .61 I 1.6T-' 1.15 1.08 ' ,J 126 116. 144 0.78 134 1.34 153 034 14 1,45 ___ 1.62 15.8 -138-736F- 1.04 17 - s u ir rTv in1Tii TTT 113 4/9/2014 Print t ..•. www.anviiinti.com ANflL Malleable Iron Screwed Fittings - Class 150 REDUCING TE #omiw Size Dimensions Approx. € I W, €och fn In, (sivi) i It. (n U, Lg) 1-94 1.66 194 1.24 1.75 04 1 - 1 82 361 1.8 1.23 1½ 1.94 10 1.94 135 1,52 145 115 104 -r '• 17 1,65 w 1 112 194 2 2 ?:19, 10 182 1 14 143 141 1.66 10 i -rTr1Tr 1.52 1135 1 114 r 2 216 Th6 20? 2 225 188 2.25 189 74 2, ?.25 397 2.25 IM 181 • 1.75 H 1.81 39 2 2.25 207 —215 j 7.00 1½ w ri 2 2 133 165 f 202j 07 2 1/ 1.90 1.02, 210 T 111 2.02 194 fl 108 1116 1 2 225 2.16 225 2.21 1.49 1A IiB LT 1.6 L DT 202 17 REDUCING TEE 3orninoI Size ....__...__-L...__!L Dimensions Approx. C WLFh 174 114 232 261 1 187 381 237 284 294 24 745 309 1 216 216 251 329 2 2.39 2,39 260 365 2 2 7T W 1' W 1 77r 200 200 Th 3 1 1 231 217 774 423 1 L/' 220 280 445 2.52 2.52 2.89 4.99 2 ?J 274 283 174 299 341 5;69 752 4 Thl- ____ http://.an4Iintl .comlProductSearcrintProduct.asp011d4380 2/3 4/9/2014 Print .- Malleable Iron Screwed Fittings - Class 150 1 REDUCING COUPLING ontiei Sire 0irneft1on A Approx. Wt. Euth LOU 0.01 1, 0.09 ny 1.25 1.2 013 - 0.13 1:25 014 1.44 0.18 X ii 1.44 0.20 1.44 .21 1.44 0.22 1.69 0.34 1.6? 0.36 10 6 47 2.06 2.06 0.57 2.31 062 1-31 066 2.31 0,13 2.31 0.80 http://anMin11.corrProductSearch/PrintProduct.aspQlid=4379 Dimensional: Fittings: ASME Si 63 Unions: ASME B 16.39 Bushings/Plugs: ASME B16.14 Material: ASIM A1 97 Goivonizing: ASIM A153(Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fjtings; ASME &16.3 U ans: ASME Sló.39 Bush[ngs/Plug: ASME 816.14 Pressure Testing; All malleable iron fittings are rested for through wall porosity using on air under water process. Agency Approvals: All malleable iron fittings and unions are Ut Listed and FM Approved, BrillA 5aederd theod•iig per 8$ 21 evcilable upon reques REDUCING COUPLING Nominal Size Dimension A Approx. WI. Eoh 2.81 0.94 2.81 0.99 2.81 1.03 2.81 2.81 i,2 2.x 1 3.2 i.81 3.25 1.90 2/i 1 ;25 2.04 x 1 3;,69 2.48 3 3.69 2.55 3x1% 3.69 2.61 3.2 3.69 2.76 3 x 21,6 3.69 3.23 4 z 2 4.38 - 4.43 2½ 4.38 4.87 4x3 4.38 5.2? 1/2 4/9/2014 Print I 1 ft F,tj) Malleable Iron Screwed Fittings — Class 150 JnD APPaUIIED c bI. S .W,k w.bt niiad Size t1'J Dirneniioit A Appox. Wt, Eith 0.96 05 .06 0.08 1.16 0.12 i13 1.52 0.27 1.7 1.43 193 05 2.iS 0.86 2 2.53 1.35 2.8 2.33 3 3 .18 3.36 4 3.69 5.59 Dimensional: Fitings: ASME B 16.3 Unions: ASME B 1639 Bushings/Plugs: AS.ME 8 16.14 Material: ASTM A- 197 Galvanizing: ASTM A- 153 (l-$oi Dip Galvanizing) Threading*: ASME 8L20.1 Pressure Rating: Fittings, ASME 816.3 Unions: ASME B16.39 Bus hings/Plugs- ASME 816.14 Pressure Tesing: All mdlleoble iron fittings ore tested for through wall porosity using on air under water process. Agency Approvals; All malleable iron fittings and unions ore UL Listed and FM Approved. Briiish Siondofd, threadiog per BS 21 avoiloble upon facluest http://wm.anintI.conProductSearch/PrintProduct.asp(?lid=4374 112 4/9/2014 Print P/NVL Malleable Iron Screwed Fittings - Class 150 . I A - 11M APPROVED Honinat Size Dimension A #pptox. Wt. Eh All emit)tl. i) thi (AJ 53 0.03 0.63 0.05 0.07 0.81 OIl 0.97 0.18 L28 0.44 2 1.45 210 3,07 4 . 6 235 8.17 SeI W/y (Wk crid Gj6nitedj. Dimensional: Ftings: ASME 816.3 Unions; ASME B 16,39 Bushin9/Plugs: ASME BI 6.14 Material: ASIM A-i 97 Galvanizing; ASTM A-153 (Not Dip Galvanizing) Threading ': ASME. 1.20.1 Pressure Rating: Fittings: ASME 8I6-3 Un[os: ASME BT6.39 shingilPlugs; ASME 316.14 Pressure Testing: All malleable iron fiffings are tested for through wall porosity using on air under water process. Agency Approvals; All malleable iron fittings and unions are UL Listed and: FM Approved. Briih $ioidrd thmading per BS 21 avoiloble upon http:/Aw.anlinU .cczfProductSearch/PrintProductasp(?Iith4373 1/2 Trust Bull Moose uirhei it comes to prtecing your most valuable assets. As the leading manufacturer of steel sprinkler ppe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength-plus reliable service. You need Bull Moose. DULL MOOSE ADVANTAGES: UL Listed (US & Canada) and FM approved ASTM A135 and A795 Type E, Grade A Certified Complies with NFPA-13 13R and 14 Industry-Leading hydraulic characteristics. CRR of 1.0 and greater All pipe NDT weld testec L red painted pipe. OTHER B5EtTS/SEWCS: We have tF:e most stocking locations in industry, fcr best delivery and aiai(abilitv Plain end or rDll groove Eddy Guard IIG bacterial-resistant internal coating Custhm length options Hot dipped galvanization Reddi-Pipe.® red pipe to eliminate field pairting Compatible f:Dr use in wet, dry, preaction and deluge sprinkler systems c®us LISTED <@APPROVED N FP Bull ii'Upii 1.660 1.900 2.315 2.815 3.500 4.500 I.D. (in) 1.530 1.728 2.203 2.705 3.334 4.310 Empty Wei -ht (Ib/ft) 1.222 1.844 2.330 2.809 3.351 4.958 CD WaterFille Weight (lb/ft) 2.019 2.860 3.982 5.299 1.144 11.290 >_ C R.R 1.98 3.44 2.18 1.66 1.00 1.00 Pieces peLift 61 61 37 30 19 19 UJ Lift Weight Otis) 21 lengths 1,565 2,362 1,810 1,710 1,341 1,982 Lift Weight lbs) 24 lengths 1,189 2,700 2,069 2,022 1,533 2,265 Lift Weight {lbs) 25 lengths 1,864 2,812 2,155 2,107 1,596 2,360 O.D. (in) 1.315 1.660 1.900 2.315 2.875 3.500 4.500 6.625 8.625 I.D. (in) 1.091 1.442 1.682 2.151 2.635 3.260 4.260 6.351 8.249 CO Empty Weight (lb/ft) 1.410 1.810 2.090 2.540 3.530 4.340 5.620 9.290 16.940 LAJ Water Fill ?d Weight (Ib/ft( 1.820 2.518 3.053 4.223 5.893 1.957 11.195 23.038 40.086 CR R 15.21 9.91 1.16 6.21 4.92 3.54 2.50 1.158 1.805 Ui Pieces per Lift 91 61 61 31 30 19 19 10 1 LA '-I Lift Weight (Ibs) 21 lengths 2,695 2,319 2,611 2,051 2,224 1,132 2,242 1,951 2,490 Lift Weighc (Ibs) 24 lengths 3,019 2,650 3,060 2,344 2,542 1,919 2,553 2,230 2,848 Lift Weigh: (Ibs) 25 lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670 O.D.(in) 1.295 1.650 1.900 2.315 I.D. (in) 1.083 1.418 1.645 2.123 Empty Weiht(lb/ft) 1.461 2.070 2.541 3.308 LAJ Water Filled Weight (lb/ft) - 1.860 2.154 3.468 4.842 C.R.R. 1.00 1.00 1.00 1.00 Pieces per Lift 10 51 44 30 CIII Lift Weigit (lbs( 21 lengths 2,148 2,211 2,353 2,084 LU Lift Weigit (lbs( 24 length; 2,454 2,534 2,690 2.382 Lift Weig:t (Ibs) 25 length; 2,557 2,639 2,802 2,481 O.D.(in) 1.315 1.660 1.900 2.315 2.875 3.500 4.500 ID. (in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Cz Empty We ght (lb/ft) 1.680 2.210 2.120 3.660 5.800 1.580 10.800 Ui Water Fifldd Weight (lb/ft) 2.055 2.918 3.602 5.114 1.815 10.183 16.316 C.R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 LAJ Pieces par Lift 10 51 44 30 30 19 19 LA Lift Weight (Ibs) 21 length; 2,410 2,431 2,513 2,306 3,654 3,024 4,309 Lift Weicht (lbs( 24 lengths 2,822 2,718 2,812 2,635 4,116 3,456 4,925 Lift Weicht (Ibs) 25 lengths 2,940 2,894 2,992 2,145 4,350 3,601 5,130 IMPERIAL MAX REC. LOAD LBS. METRIC* PIPE ROD PIPE ROD 400 10 3/4 3/8 400 20 io 1 3/8 400 25 10 400 32 10 11/2 400 40 10 2 3/8 400 5010 21/2 3/8 600 5 10 3/8 1 600 80 10 31/2 3/8 600 to 3/8 1000 loo 10 5 1250 125 12 6 1260 1 150 1 12 8 1250 —A 200 12 * Order Part #300m Note: 1/2" Ring Hanger not <FM> approved 112 and 3/4 inch pipe 5 thru 8 inch pipe JA P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEEL/CPVC SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - C®LJ 203-EX 2551 <a> Approval guide - Pipe Hangers OSHPD OPA-060 1 See Website. CONFORMS WITH: Federal Specification WW-H- 171 (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION - Per NFPA-13, 13R and 13D. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. 2/07 Mechanical-I® STYLES 920 AND 920N STYLE 920 CROSS PATENTED STYLES 920 AND 920N Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HOPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap III hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-340C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-290C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. "Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para Location Date Approved www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REVJ htauiicr 11.02.) IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 1 L. 7 .J Uiiiia I LlII8a thI1tft81 IIIII 1L4)14a flL4 Ue Asp QW M'1 1it t 2 1/2 (a) 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 - 50 15 3450 38.1 51 64 - 41 136 70 1.5 I 1/4 (a) 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3.1 - - 20 3450 38.1 50 64 - 41 136 70 1.5 + 1(a) 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 64 41 136 70 1.4 1 /4 (a) I' 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 3450 44.5 52 70 76 41 . 136 76 1.7 1.5 1½ (a) I' 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 Y -Z--- 2½ 1/4(a) 920N 500 1.50 2.21 2.74 - 91.82 5.64 2.75 3.0 - Fr 65 15 3450 38.1 56 70 46 143 70 1.4 3/4 (a) 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 V 20 3450 38.1 55 79 .. 46 . 143 70 1.4 1 1(a) 920N 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 - -- - - - - 25 2 3450 38.1 52 70 - 46 143 70 1,4 W 1¼t (2) 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 920N 3450 . 44.5 . 58 76 83 46 160 76 1.7 1.5 1½ I' (a) ON 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 FEMALE THREADED OUTLET 40 92 3450 50.8 58 76 83 46 159 83 1.7 1.6 ½ (a) 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 76.1 >< 15 920 2.065 38.1 56 70 - 57 164 81 1.8 - Provides a direct branch connection at 3/4(a) 920 300 1.50 2.19 2.75 2.25 6.46 3,18 3.9 any location where a hole can be cut 20 2065 38.1 56 70 -57 164 81 1.8 - in the pipe 1(a) 920 300 1.50 2.07 2.75 - 2.25 6.46 3.18 3.8 - 25 2065 38.1 53 70 57 164 81 1.7 A pressure responsive gasket provides 1 1/4 a1 920 500 1,75 2.30 3,00 3.31 . 1.92 6.29 3.00 3.5 3.2 the seal __32 _-J 3450 44.5 58 , 76 84 49 160 76 1.6 1.5 1½ (a) 920 500 2.00 2.28 3.00 3.31 1.92 6,29 3.25 3.5 3.3 Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 Mechanical-T cross assemblies 3 ½ (a) 920N 500 1,50 2.52 3.05 - 2.28 6.15 2,75 3.4 - 80 15 3450 38.1 64 78 58 156 70 1.6 Pressure rated up to 500 psi/3450kPa '14(a) 920N 500 1.50 2.49 3.05 2.28 6.15 2,75 3.4 - on steel pipe; also available for use 20 3450 38.1 63 78 58 156 70 1.6 with HDPE nine 1(a) 20N 500 1.50 2.38 3.06 2.28 6,15 2.75 3.3 1' - 25 3450 38.1 61 78 58 156 70 1.6 Sizes from 2 x 1/2750 x 15 mm 1'4(a)t) 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 through 8 x 4/200 x 100 mm 3450 44.5 65 83 90 58 156 76 1.8 . 1.8 11/2 (a) t 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 . 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2 (a) 920N 500 2.50 2,75 3.50 3.56 ' 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 3½ 2 500 2.50 3.75 2.44 6.72 3.88 1 3.8 90 50 920N 3450 63.5 , " - 95 62 171 99 I 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG. 3 Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com - VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA, ictaulic 11.022 REV.) IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS ____ __ __ thi3raa 6aJia Uiza a8 __ ' .i O I TABLE CONTINUED FROM PAGE 2 ½ 4 920N 500 1.50 3.03 3.56 2.69 7.01 2.75 3.7 I 100 3450 38.1 77 . 90 - 68 178 70 1.8 - - - ~ (a) N 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 920 3450 381 76 90 - 68 178 70 1.8 - 1j1 920N 500 3450 95 2,88 3.56 - 269 7 25 ,3 90 68 178 70 1.8 GROOVED OUTLET i 1,4 (a) t 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 40 3.6 32 (b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 1/2 (a) t 920N 500 2.00 3.28 4.00 4.00 2,69 7.01 3.25 4.2 39 ( z 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 ______ 920N 35 450 35 3235 400 4.00 2.69 7. 3.88 5.0 46 102 102 68 178 99 2.3 2.1 V I' 2½ (a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 . 2.3 - - - - - - 76.1 920 500 2.75 4.00 2.69 7.34 4.63 6.4 w . mm 3450 69.9 - - 102 68 186 118 2.9 3 (a) I' 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 920 3450 88.9 84 114 105 68 196 130 3.8 2.9 FEMALE THREADED OUTLET X . 1% (3) ( 920N 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 __.a._j 3450 44.5 78 96 - 67 194 78 2.3 - 1 ½ (a) N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 Provides a direct branch connection at 920 3450 50.8 83 102 - 67 194 83 2.3 - any location where a hole can be cut 2(a) "1 500 2.50 3.25 ' 4.00 - 2.63 7.64 4.00 4.0 in the pipe 50 920N 3450 63.5 83 102 67 194 102 1.9 - 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 A pressure responsive gasket provides 76.1mm 920 3450 69.9 , 73 102 102 67 194 109 3.6 the seal 3(a) 920 500 3.50 3.31 4.50 - 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 67 194 124 3.1 3.0 Request Publication 11.03 for 5 1½ (a) 1' 920 500 2.00 4.03 . 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 X 3450 50.8 102 . 121 121 80 246 94 3.4 3.4 2(a) '1' 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 Pressure rated up to 500 psi/3450kPa 3450 63.5 102 121 121 80 , 246 111 3.7 3.6 on steel pipe; also available for use 21/2 (a) t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 3450 69.9 , 92 121 121 80 246 118 3.8 3.6 500 2.75 4.75 3.16 9,70 4.63 8.0 Sizes from 2 x ½u/50 x 15mm 76.1 mm 920 3450 69.9 - - 121 80 246 118 - 3.6 through 8 x 4/200 x 100 mm 3(a) t 920 500 3.50 3.81 1 5.00 4.63 3.16 ' 9.70 5.31 8.4 8.8 80 3450 88.9 97 127 118 80 246 135 3.8 4.0 2 1 920N 500 2.50 3.75 4.50 3.17 8.00 3.88 8.0 133.0 >( 50 3450 63.5 95 114 - 81 203 99 3.6 - 920 500 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 3450 88.9 97 127 - 76 240 135 3.6 - TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REVJ I. I ~ AtEauIicf 11.02,_3 FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HOPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm IP3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 1 L iI M Qu 8 TABLE CONTINUED FROM PAGE 3 1397 ' 920N 500 2.00 3.78 . 4.50 3.30 8.23 3.25 7.0 40 3450 50.8 96 = 114 - 84 209 83 3.2 - 2 1 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 - , 84 209 99 4.1 - 761 mm 920 500 2.75 3.63 4.75 3.13 9.85 4.63 8.8 3450 69.9 92 121 - 80 250 118 4.0 - 761 mm 920 500 3.50 4.63 3.16 9.70 5.31 11.0 3450 88.9 - . - '118 80 246 135 5.0 920 500 3.50 3.81 5.00 4.63 3.16 9.85 5.38 14.0 14.2 88.9 920N 3450 500 88.9 1.75 96.80 4.43 127 118 80 3.79 250 9.15 137 3.25 6.4 6.4 4.8 6 1¼(a) XSb) 150 3450 44.5 112 - - 96 232 83 - 2.2 1½ (a) I' 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) 1' 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 . 130 130 96 232 99 2.7 2.5 21/2 (a) t 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 761 mm 920 500 2.75 5.21 3.69 10.51 4.63 8.4 3450 69.9 - - 132 94 267 118 - 3.8 3(a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a) 1' 920 500 4,50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 20 9 N 3450 500 114.3 1.75 97 4.43 146 5.13 137 . 94 3.63 267 9.40 159 3.25 4.6 9.0 4.6 8.7 1¼ 159.0 x 32 3450 44.5 113 130 - . 92 239 83 4.1 4.0 11/2 (a) 920N 500 2.00 4.41 5.13 3.63 9.40 3.25 7.8 40 3450 50.8 112 130 - 92 239 83 3.5 - 2 (a) 920N 500 2.50 4.38 . 5.13 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 - 92 , 239 99 3.6 - 761 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 90 2 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.1 mm 920 500 4.50 - - 5.38 3.63 9.40 6.12 - 10.0 3450 114.3 137 92 239 155 4.5 4 920 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 100 3450 114.3 96.80 146 - 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com '¼l(ctauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAuLIC COMPANY. 0 2007 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 11.02_4 . REV_J IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N dimensions Inc UNION GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 mm through 8 x 4/200 x 100 mm TABLE CONTINUED FROM PAGE 4 165.1 >< 1 920 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 99 116 - 96 237 70 3.6 - 1 4 920 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 - 96 237 83 3.8 - 1 ½ (a) t 920 500 2.00 4.41 5.13 3.79 9.34 3.25 8.4 40 3450 50.8 112 130 - 96 237 83 3.8 - 2(a) I' 920 500 2.50 4.38 . 5.13 3.79 9.34 3.88 . a.s 50 3450 63.5 111 130 - 96 237 99 3.9 - 2½ i 920 500 2.75 4.01 5.13 3.63 10.51 4.63 8.6 7.6 65 3450 69.9 110 130 - 92 267 118 3.9 3.4 76.1 MM 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 . 110 130 132 92 267 118 3.9 3.4 3(a) 1' 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 80 ,, 3450 88.9 110 140 130 92 267 135 ....3.8 4(a) t 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 2(a) t 20 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 3450 69.9 138 157 159 122 316 114 5.3 5.3 2/2 (a) t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 . 129 157 157 122 316 114 5.3 5.3 76.1mm 920 500 2.75 6.25 4.81 12.42 4.56 11.6 3450 69.9 - - 159 122 316 116 - . 5.3 3(a) t 920 500 3.50 5.31 6.50 6.50 4.81 12,42 5.31 12.6 11.6 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 4(a) t 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. (a) British Standard female pipe threaded outlet is available as listed. Specify 'BSPT clearly on order (b)For 76.1 mm threaded outlet, specify 2½ BSPT clearly on order. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAuLIC IS REGISTERED TRADEMARK OF vlcTAuuc COMPANY. © 2007 vicTAuLic COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REVJ \/ C- tauIicf 11.025 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalT® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C, Values Values for flow of water at +60°F/+16°C are shown in the table below. gth __1JJJL Feet/meter of Pipe 1h 0.840 2.0 2 2.375 9.0 10.5 15 213 - 0.6 60.3 2.7 3.2 3/~ 1.050 4.0 21/2 I 2.875 11.0 12.5 20 26.7 - 1.2 65 73.0 3.4 3.8 Exaggerated for clarity 1 1.315 - 5.0 3 3.500 13.5 15.5 25 33.7 1.5 80 88.9 4.1 4.7 1'/4 1.660 5.5 6.0 41 4.500 20.0 22.0 32 42.4 1.7 1.8 100 114.3 6.1 6.7 11/2 1.900 7.0 8.0 40 48.3 2.1 2.4 Formulas for C, Values: = Q2 C92 Q = C x Where: Q = Flow (GPM) 1P = Pressure Drop (psi) C = Flow Coefficient www.victaulic.com iCtUliC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIc COMPANY. 0 2007 VICTAULIc COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 11.02_6 REV_i IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N APPROVED PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publi- cation. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size ImlrI.1 mr z I . I LAW,. . . 21/2-6 2.875 - 6.625 All 10,40 400 400 400 65-150 73.0-168.3 2755 2755 2755 21/2 -4 2.875 - 4.500 All OF 300 300 300 65-100 73.0-114.3 2065 2065 2065 21/2-4 2.875 - 4.500 All SF 300 300 300 65-lOa.J 73.0-114.3 2065 2065 2065 6 6.625 3 4 10 300 300 250 150j ... 168.3 2065 2065 1724 168.3 2065 . 2065 . 2065 6 6.625 34 3040 300 300 300 150 8 j 8.625 21/2 10,40 400 - - 2O0J 219.1 ' 2755 8 8.625 3 ' 4 10 300 250 200 - 219.1 2065 1724 8.625 300 300 3,4 30.40 200 - 219,1 2065 2065 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 8"/100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-I unit, which is a combination of the Style 920 Mechanical-I and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100 mm, 57125 mm, 6'7150 mm and 8/200 mm diameter pipe. The Style 931 comes with a 21h"/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.vjctaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV,J Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 11111111111111111111111111111111111111111111111 WCAS-6YCLDG For complete contact information, visit www.victaulic.com 11.02 1480 REV 4 UPDATED 4/2007 X /ictauiiiie VICTAULIC IS REGISTERED TRADEMARK OF VICTAUUC COMPANY. © 2007 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 11.028 SAMM A fl I akesithe Press to the f X-Treme" <S> CQS APPROVED LISTED _ Part No Wood UL UL Max Pipe UL Test Mm. Wood FM FM Max I'M Test Min. Wood Size, in. Load Thickness, in. Pipe Size ..oad Thickness, in. 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST20SS X 2-1/2 850 1.5 8010957 GST30 X 4 1500 1.5 X. 4 1475 1.5 8009925 GST25-380 X 4 1500 1.5 8022925 SWG 25-380 X 31/2 4 1500 15 8021957 SWG 20 X 2-1/2-3 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SHGST20 X 3 1050 1.5 X 4 P475 1.5 8141957 SI-I GST3O X 4 1500 1.5 X 4 1475 1.5 Part N Steel UL UL Max Pipe UL Test Mm. Steel FM FM Max FM Test Mm. Steel No. ee Size, in. Load Thickness, in. Pipe Size Load Thickness, in. 8038957 DSTR1 X 4 1500 .035 X 4 1475 .1050 8037957 DSTR1-1/2 X 4 1500 .035 X 4 1475 .1050 6039957 DSTR 516 X 4 1500 037 X 4 1475 1050 8045957 DST 516 X 4 1500 .188 X 4 1475 .1875 8046957 TEK50 X 4 1500 .250 X 4 1475 .1875 8055957 SWDR 1 X 4 1500 .037 X 4 1475 .0600 8056957 SWDR 516 X 4 1500 .037 X 4 1475 .0600 8054957 SWDR 1-1/2 X 4 1500 .037 X 4 1475 .0600 8137957 SHDSTR1 X 4 1500 .035 X 4 1475 .1050 8150922 XP 20 X 2-1/2 850 .027 X 4 1475 .1050 8153922 XP 35 X 31/2 1250 043 X 4 1475 1050 8294922 SXP20 X 2 750 .027 X 4 1475 8295922 SXP35 X 3-1/2 1250 .060 X 4 1475 8293957 SWXP 35 X 3-1/2 1250 .060 X 4 1475 UL Max Pipe UL Test . FM Max M Test Part No. Concrete UL i Mm. PSI FM Material Size, n. Load Pipe Size Load 8059957 CST 20 3000 X 4 1475 3000 PSI 8061957 SWC20 3000 X 4 1475 3000 PSI 8150922 XP 20 X 2-1/2 850 Pre Pour Structural 3000 PSI 8150922 XP 20 X 2-1/2 850 Post Pour Range II LWC :5 35 PCF *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2 *SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4 SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1I2 SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 2-1I2' SXP 20 Maximum allowable angle in 22 ga. steel is 45 UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement 5 times weighth of water filled schedule 40 pipe 250 pounds. f\ ividex www. itwbuildex. corn 800-BUILDEX SSS39 082007 sw V Worldwide i Fire Protection Contacts www.tyco-fire.com Products Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. • A L!ii1.'i4JélIA áj TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psill2 (80,6 LPM/bar112) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button .............. Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 (50, \ / WRENCH FLATS DEFLECTOR * p— 2-7/8 (73,0 mm) DIA. PENDENT RECESSED PENDENT TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON CROSS SECTION 1 7/16 (111mm) I NOMINAL MAKE-IN 2 (50,8 mm) 1/2" NPT** UPRIGHT FIGURE 1 SERIES TV-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER I FITTING I 5/8 (15,9 mm) FLUSH 3/8±5/16 (9,5±7,9 mm) \ / MOUNTING / SURFACE (3,2 MM) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. FITTING (57,2 mm) (7,9±6,4 mm) 1/2 (12,7 mm) FLUSH A!1/ MOUNTING 1/8" J SURFACE \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N* 77-XXX-X-XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 370 5.6K UPRIGHT (1/2 NPT) TY313 371 5.6K PENDENT (112 NPT) TY323 * Use suffix "I" for ISO 7-1 connection; 1 NATURAL BRASS 3 PURE WHITE (RAL9010)°° POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 9 CHROME PLATED for example, 77-370-4-175-I - Eastern Hemisphere sales only 135 135°F(57°C) 155 155-F (68-C) 175 175-F (79-C) 200 200°F (93°C) 286 286°F (141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products 0 Worldwide www.tyco-fre.com Contacts Series RFIII - 5.6 K4actor General Description The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers Quick Response (3-mm bulb) and Standard Response (5-mm bulb), are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFll Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document and with the applicable standards of the National Fire Protection Association, in addi- tion to the standards of any authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb 1Y3551 - 5 mm bulb Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. MARCH 2013 TY3531 (3-mm Bulb) is UL Listed, C-UL Listed, VdS Approved (Certif- icate No. G4090007), and NYC Ap- proved (MEA 353-01-E) as Quick Response. 1Y3531 (3-mm Bulb) is FM and LPCB Approved (Ref. No. 094a/10) Approved as Standard Response. Factory Mutual and LPCB do not approve any concealed sprinklers for quick response. 1Y3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a/9), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFlI Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F (68°C) Sprinkler with 139°F (59°C) Plate 200°F (93°C) Sprinkler with 165°F (74°C) Plate Discharge Coefficient K= 5.6 GPM/psi112 (80,6 LPM/bar112) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. TFPISI TFPI8I Page 2 of 4 Physical Characteristics Frame ...................Bronze Support Cup..............Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel w/ TEFLON Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel Design Criteria The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency; for example, UL List- ing is based on NFPA 13 and VdS Ap- proval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Pro- tection Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFII Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. Do not use the Series RFII in applica- tions where the air pressure above the ceiling is greater than that be- low. Down drafts through the Sprin- kler/Support Cup Assembly can delay sprinkler operation in a fire situation. When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector - supported by the Guide Pins - then drops down to its operational position. The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, activating the sprinkler and allowing water to flow. 1/2 NP1 FRAME SUPPOR CUP Will ROLL FOR THREAD GUIDE PINS (2) DEFLECTOR Installation The TYCO Series RFII 5.6 K-factor, "Royal Flush II" Concealed Pendent Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F (68°C) and 3/32 inch (2,4 mm) for the 200°F (93°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler In- let with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFll Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and LECTOR ROPPED POSITION) ------------- SPRINKLER/SUPPORT CUP ASSEMBLY EALING SEMBLY CAP BULB PRESSION CREW THREAD INTO fl RETAINER SUPPORT H WITH THREAD CUP UNTIL 0 0 _- DIMPLES MOUNTING SURFACE IS EJECTION FLUSH WITH SPRING CEILING _/ L SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING DIMENSION C SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, I RETAINING RING 74 MOUNTING SURFACE 5 I II II II 3/16 to 11/16 MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32 (2,4 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE PROFILE DEPTH DIAMETER DIMENSION B DIMENSION A 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPI8I Page 3 of 4 Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. As long as the Protective Cap remains in place, the system is considered 'Out of Service' Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) di- ameter clearance hole and in prepa- ration for installing the Cover Plate! Retainer Assembly, remove and dis- card the Protective Cap. Verify that the Deflector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate! Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. TFPIBI Page 4 of 4 SUPPORT SPRINKLER FACE OF ORIENT CUP / CEILING SEAL BEVEL AS COVER A REPLATE TAINER SHOWN ASSEMBLY COVE RAIR AND DUST LIP OF SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) Care 7and (Jit1tL'{I The TYCO Series RFII 5.6 K-fac- tor, "Royal Flush II" Concealed Pen- dent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be affect- ed by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: Series RFII (specify SIN), K=5.6, "Royal Flush II" Pendent Sprin- klers (specify) temperature rating and (specify) finish, P/N (specify). 155°F (68°C) 200°F (93°C TY3531 51-792-1-155 51-792-1-200 1Y3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F (59°C)(a) 165°F (74°C)(b) Grey White (RAL9002) .... 56-792-0-135 56-792-0-165 Brass..........56-792-1-135 56-792-1-165 Pure White (c) (RAL9010) ... 56-792-3-135 56-792-3-165 Signal White (RAL9003) .... 56-792-4-135 56-792-4-165 Jet Black (RAL9005) .... 56-792-6-135 59-792-6-165 Brushed Chrome ........56-792-8-135 56-792-8-165 Chrome........56-792-9-135 56-792-9-165 Custom ........56-792-x-135 56-792-X-165 For use with 155°F (68°C) sprinklers. For use with 200°F (93°C) sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. Contact the in- stalling contractor or sprinkler manu- facturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont corporation. tqca 1539 REV 10.03 VICTAULIC6 IS AN ISO 9001 CERTIFIED COMPANY PRODUCT DESCRIPTION DIMENSIONS I.0 to E CtoE to E 7 No. 001 No. 003 C - to E -_ T It to tk- - IE No. 002 No. 006 FireLock5 products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. Patented See Victaulic publication 1001 for details. No. 001 No. 003 N? 002 No. 006 Fitting Size 90 Elbow 45 Elbow Straight Tee Cap Actual Aprx. Aprx. Aprx. Thickness Aprx. Nominal Outside C to E Weight C to E Weight C to Weight 'T' Weight Diameter Diameter Inches Each Inches Each Inches Each Inches Each Inches/mm Inches/mm mm Lbsikg mm Lbs/kg mm Lbs/kg mm Lbs/kg 11/4 1.660 - - - - - - 0.82 0.3 32 42.4 - - - - - - 21 0.1 11/7 1.900 2.75 1.2 1.75 0.9 2.75 2.0 0.82 0.4 40 48.3 70 0.5 45 4.1 70 0.9 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 - - - - 76.1 76 1.5 57 1.1 - - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 - - 108 mm 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2,4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4,1 126 141.3 124 5.7 83 3.8 124 7.1 25 1.9 6.250 5.50 12.6 3.50 9.2 3.50 17.9 - - 159 mm 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 REGISTERED TRADEMARK OF VICTAULIC - © COPYRIGHT 2006 VICTAULIC - PRINTED IN U.S.A. - SKU #WCAS-67PJUX United Stales Phone: 1-800-PICK-VlC (1-800-742-5842) • Fax: 610-250-8817 • e-mail: pickvic@victaulic.com Canada • Phone: 905-684-7444 • Fax: 905-884-9174 • e-mail: viccanada@victaulic.com Europe Phone: 32-9-381-1500 • Fax: 32-9-380-4438 e-mail: viceuro@victaulic.be UK Phone: 44(0)1438741100. Fox: 44(0)1438313883 • e-mail: viceuro@victaulic.be Central and South America • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: vical@victaulic.com Australasia • Phone: 86-21-54253300 . Fax: 86-21-54253671 • e-mail: vicap@victaulic.com 10.03 FLOW DATA Frictional Resistance Fittina Size Equivalent Feet/meters of Straight Pipe Actual StraightTee Nominal Outside No. 002 Diameter Diameter 90 Elbow 45 Elbow Inches/mm Inches/mm No. 001 No. 003 Branch Run 174 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 1/? 1.900 2.2 1.1 5.5 2.2 40 48,3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 211 2.875 4.3 2,2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 76.1 mm 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108 mm 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 6.250 9.4 4.9 25.0 9.6 159 mm 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 The flow data listed is based upon the pressure drop of Schedule 40 pipe. MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12 Fitting Coating: Orange enamel Optional: Hot dipped galvanized This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with Current Victaulic installation/assembly instructions. Victaulic reserves the right to Change product specifications, designs and standard equipment without notice and without incurring obligations. FirelLockg Fittings FireLock EZTM Rigid Coupling Para____________ CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved JOB/OWNER System No. Location STYLE 009 (UL, FM) STYLE 009V (UL, FM, VdS, LPCB) The FireLock EZ Style 009 and Style 009V couplings are rigid, pre-assembled couplings for fire protection pipe joining. The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009 and Style 009V couplings are recommended for use ONLY on fire protection systems. PATENTED STYLE 009 LISTINGS/APPROVALS ifS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. STYLE 009V LISTINGS/APPROVALS ifs itt 16Bar 16Bar 168ar - § 76.1 mm - 232 psi 232 psi 232 psi —4 § 1½-4,76.lmm 1613ar 16Bar - - 32-100 232p5i 232 psi 14 - 20.7 Bar - 20.7 Bar 20.713ar 32 300 psi 300p5! 300psi 1 1/2 - 20.7Bar - 20.7 Bar 20.713ar 40 300psi 300 psi 300psi 2 20.7Bar 20.7 Bar 20.7Bar - 10 40 50 - 300psi 300psi 300psi 1 3 - 20.7Bar - 20.7Bar 20.78ar 80 300psi 300psi 300 psi 4 - 20.7 Bar - 20.7 Bar 20.78ar I 100 300psi 300 psi 300 psi t Listed/Approved for wet and dry pipe systems (> -40F/-40C). For rigid pipe connections in systems operating below 0F/-180 Victaulic recommends Style 005 FireLock rigid couplings with Grade silicone gaskets. * Please refer to the Victaulic Field Installation Handbook (1-100) for details concerning when supplemental lubrication is required. § Style 009V couplings are VdS and LPC approved to 16Bai/232 psi for wet and dry fire protection systems. www.victaulic.com - VICTAULIC Is A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. cta _U1 ii REV_G I0.60...1 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.60 FireLock EZTM Rigid Coupling STYLE 009 (UL, FM) STYLE 009V (UL, FM, VdS, LPCB) STYLE 009 DIMENSIONS 4 LL ____ / /1'\ \ I 'I tI1T180 Ifli2w 1 Fri innr I_i-1 ...L 1 cj IF P71 Im. x 1¼ 1.660 300 649 0. 3/ 10 2 3.13 4.93 2.86 4.83 1,93 15 32j 42.4 2068 2888 2.54 - r< 2 80 125 73 123 49 0.7 11/2 1 1.900 300 851 0.10 2 3/ 2 3.38 5.16 3.11 5.07 1.86 1.7 404 48.3 2068 3787 2.54 - 86 131 79 129 47 0.8 STYLE 009 PRE-ASSEMBLED 2 2.375 300 1329 0.12 2 3/ 2½ 388 5.81 3.59 5.68 1.86 1.9 (STAB IN CONDITION) 5O 60.3 2068 5914 3.05 - 99 148 91 144 47 0.9 2½ I 2.875 300 1948 0.12 4.38 6.21 4.08 6.10 1.87 2.0 V 65j 73.0 2068 8668 305 2- /8 x2 , 111 158 104 155 48 0.9 k7A 3 1 3.500 300 2886 0.12 2 - 3/ 2 5.06 6.68 4.73 6.43 1.90 ' 4.3 80 88.9 2068 12842 3.05 129 170 120 163 48 2.0 X '"14.500 300 4771 0.17 ' - 2 8 2/i 6.46 8.64 ' 6.00 8.34 2.10 2.3 100 114.3 2068 21230 4.32 x 164 220 152 212 53 . 1.0 @ + Refer to notes below. STYLE 009 JOINT ASSEMBLED STYLE 009V DIMENSIONS 4 Z. n' Az_- x 1¼ 1.660 300 649 010 2 Ml 57 314 484 285 465 191 16 32 424 2068 2888 254 - 80 123 72 118 49 0.7 1½ 1.900 300 851 010 334 506 313 485 1.92 1.7 40 48.3 2068 3787 2.54 2-M10 57 85 129 80 123 49 0.8 STYLE 009 PRE-ASSEMBLED 2 1 2.375 300 1329 0.12 2 M10 4 391 566 361 547 1.94 2.1 (STAB IN CONDITION) 50 603 2068 5914 305 - X 99 144 92 139 49 0.9 Fw_t~; _______761 3000 300 1948 012 M 457 646 417 6.18 1.96 2.3 Y mj 76.1 2068 8668 3.05 2- 10 s64 116 164 106 157 50 1.1 3 3.500 300 2886 0.12 Ml 64 515 712 473 6.67 1.94 2.6 80 889 2068 12842 3.05 2- 0 131 181 120 169 49 1.2 X 4 4.500 300 4771 0.17 M 6 639 874 605 8.46 2.11 . 4.6 100 1143 2068 21230 4.32 2- 10 4 162 222 154 215 54 2.1 * Working Pressure and End Load are total, from all internal and external loads, based on STYLE 009 JOINT ASSEMBLED standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See pages 3 and 4 of this document for Listed/Approved ratings on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 ½ times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. www.victaulic.com tauluc VIcTAULIC Is A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. uc 10.602 REV_G IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.60 FireLock EZTM Rigid Coupling STYLE 009 (UL, FM) STYLE 009V (UL, FM, VdS, LPCB) MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America) Red enamel (Europe) Optional Coatings: Hot dipped galvanized Gasket: Grade E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2007 vIcTAuLIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV_G 10.60.3 STYLE 009 (UL, FM) STYLE 009V (UL, FM, VdS, LPCB) GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009 and Style 009V couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. III IIIIlIDIIIIIIIIIIIlIIIIIlIIIIIIII I WCAS-6VZQGR For complete contact information, visit www.victaulic.com 10.60 3999 REV G UPDATED 712007 ,ctauIc VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. 10.60 Listed* 300 psi Description Manufactured from cast brass*, our angle valves are for Trim or Drain applications and are designed to be suitable for all sprinkler systems including high pressure systems. The soft seat design utilizes NBR Nancar N70 material or PTFE for positive sealing to 300 psi. The most common use for the 2" IPS size is as a system drain at the riser. May be used on both alarm valve and shotgun type riser assemblies. Directions Installation of the Trim/Drain valves can be accomplished using normal installation meth- ods. It is important to "hold back" each component in the piping assembly to prevent over-tightening of the previ- ously installed component. Use a suitable thread seal- ant such as PipeFit Thread Sealant with PTFE* or FPPI PTFE Pipe Thread Tape to as- sure a positive seal between *Contains lead. Not for use in water sys- tems intended for human consumption. Specifications Materials Cast Brass*: Body Bonnet Brass* ASTM B16: Gland Holder Stem Washer Stainless Steel: Nut NJBR Nancar N70 Rubber seat itS FC2O: Hand wheel Sizes: 1/2" IPS FxF 3/4" IPS FxF IPS FxF 1 1/4" IPS FxF 1 1/2" IPS FxF IPS FxF the valves and the installed pipe. * UL/ULC Listed, 2R97. Caution: Do not overtighten male threads into the valve body. Thread damage or cracking of the valve body may occur. ©1996-2009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 1 800 344-3775 fax• www.fppi.com FOO _Ta- W ~ i Ms- Description 60ii FPPI 's Sprinkler Gauge Kits provide everything needed to install a fire sprinkler gauge to a riser or other device. Each kit contains a pressure gauge that is UL Listed and FM approved for Fire Sprinkler Service, 1/4" brass 3-way valve, 1/4" x 1/2" galvanized reducer, 1/4" IPS x 4" galvanized pipe nipple and a 1/4" IPS gal- vanized plug. Each kit is shrink wrapped to a sturdy cardboard backing to prevent the loss of the components before being installed at the job site. Available with Water, Air-Water, Air or Air with Retard fire gauge. Specifications 11-565 Pressure Gauge Kit, Water 11-566 Pressure Gauge Kit, Air-Water 11-567 Pressure Gauge Kit, Air 11-568 Pressure Gauge Kit, Air w/Retard 7~06 I Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 ©1989-2009 Fire Protection Products, Inc (FPPI) f Jt E 1. For questions: 1 800 344-1822• 1 800 344-3775 fax www.fppi.com Meets requirements of the Buy American Act Use for both lateral and longitudinal sway brace applications Unique slotted holes provide for easy slip-on installation eliminating loose hardware Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1' through 2" brace pipes to reduce inventory Meets NFPA®-13 requirements for seismic sway bracing FM® Specification Tested Material: Steel Finish: Electrogalvanized C@US 4~~ OSHPD APPROVED Part Number Pipe Size Brace Pipe Size Width Angle A B• C 0 CSBO100 1" 1-2 1 1/2 45° 39/16' 1 5/16' 5/8" 5" CSBO125 1 1/4' 1-2' 1 1/2" 45° 39/16' 1 5/16" 11/16' 51/2' CSBU150 1 1/2' 1-2" 11/2" 45° 39/16" 1 5/16" 3/4" 53/8" CSB0200 2" 1"- 2" 1 1/2" 45° 39/16" 1 5/16" 13/16" 6" CSB0250 2 1/2" 1"- 2" 1 1/2" 45° 39/16" 1 5/16" 15/16" 6 3/4" CSB0300 3" 1" - 2" 1 1/2" 45° 3 9/1 6" 1 5/16" 1" 73/8" CSB0400 4" 1"- 2" 1 1/2" 45° 39/16" 1 5/16" 1 1/16" 8 1/2" CSBOSUO 5' 1" -2" 11/2" 45° 39/16" 1 5/16" 1" 10 1/16' CSB0600 6" 1"- 2" 11/2" 45° 39/16" 15/16" 1 1/8' 10 7/8" CSBO800 8" 1-2" 11/2" 45° 39/16". 15/16" 11/4" 1 13" CSB1000 10" 1"- 2" 11/2" 45° 39/16" 15/16" 1" 153/16" UL Loads Part Number Lateral . . Longitudinal 5ch 10/Sch 40 Service Pipe Bull Moose Eddy Flow Service Pipe Wheatland Mega-Flow Service Pipe Youngstown Fire-Flo Service Pipe Sch 10/Sch 40 Service Pipe Bull Moose Eddy Flow Service Pipe Wheatland Mega-Flow Service Pipe Youngstown Fire-FLo . Service Pipe CSB0100xx 2,765 Lb N/A N/A N/A 1,600 lb N/A N/A N/A CSB0125xx 2,765 lb 2,765 lb 2,765 lb . N/A 1,000 lb - 1,00016 1,000 lb 1,000 Lb CSBO15Oxx 2,765 lb 2,765 lb 2,765 lb 2,765 Lb 1,600 lb 1,600 Lb 1,600 lb 1,600 lb CSB0200xx 2,765 lb 2,765 lb 2,765 lb 2,765 lb . 2,015 lb 2,015 lb 2,015 lb 2,015 lb nnt CADDY UL Loads Part Number Lateral Longitudinal Sch 10/Sch 40 Service Pipe Bull Moose Eddy Flow Service Pipe Wheatland Mega-Flow Service Pipe Youngstown Fire-Flo Service Pipe Sch 10/Sch 40 Service Pipe Bull Moose Eddy Flow Service Pipe Wheatland Mega-Flow Service Pipe Youngstown Fire-Flo Service Pipe CSB0250xx 2,765 lb 2,765 lb 2,765 lb 2,765 lb 2,015 lb 2,015 lb 2,015 lb 2,015 lb CS80300xx 2,765 Lb 2,765 lb 2,765 lb 2,765 lb 2,100 lb 2,100 lb 2,100 to 2,100 lb CS80400oo 2,765 Lb 2,765 Lb 2,765 Lb 2,765 Lb 2,600 lb 2,600 lb 2,600 lb 2,600 lb CSB0500xx 2,765 lb N/A N/A N/A 2,600 Lb N/A N/A N/A CSB0600xx 2,765 lb N/A 2,765 lb N/A 2,600 to N/A 2,600 lb N/A CSBQ800xx 2,765 Lb N/A N/A N/A 2,600 Lb N/A N/A N/A CSB1000xx 2,8001b N/A N/A N/A 2,8001b N/A I N/A N/A FM Loads Part Number Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal 30'-44- 45 59 60--74- 75 90 30 44 45--59- 60 74 75--90- FM Approved LightwaLL, Sch 10 and Sch 40 Service Pipes 0.188" Wall and Sch 40 Service Pipes CSB0100xs 1,490 lb 2,110 lb 2,580 Lb 2,900 lb 1,290 lb 1,240 lb 1.260 Lb 1,400 lb CS80125xx 1,380 lb 1,960 lb 2,400 Lb 2,690 lb 1,290 lb 1,240 lb 1,260 Lb 1,400 lb CSB0150xx 1,380 lb 1.960 lb 2,400 lb 2,690 to 1,200 lb 1,860 lb 2,180 lb 2,250 Lb CSB0200ox 1,380 Lb 1,960 lb 2,400 to 2,690 Lb 1,200 lb 1,820 lb 2,180 to 2,250 lb CSB0250xx 1,440 lb 2,030 lb 2,490 lb 2,790 lb 1,320 to 1,820 lb 2,190 lb 2,500 lb CSB0300xx 1,390 Lb 1,970 lb 2,420 lb 2,710 lb 1,300 lb 1,790 lb 2,190 Lb 2,500 to CSB0400xx 1,390 lb 1,970 lb 2,420 lb 2,710 lb 1,300 lb 1,790 lb 2,190 lb 2,500 lb CSB0500xx 1,390 lb 1,970 lb 2,420 lb 2,710 lb 1,300 lb 1,790 to 2,190 lb 2,500 lb CSB0600xx 1,460 Lb 2,060 Lb 2,520 lb 2,830 lb 1,410 to 1,950 to 2,350 lb 2,680 lb CSB0800xx 1,330 lb 1,880 Lb 2,300 lb 2,580 lb 1,400 lb 1,920 lb 2,350 lb 2j640 lb CSB1000xx 1,330 Lb 1,880 Lb 2,300 Lb 2,580 lb 1,400 lb 1,920 Lb 2,350 lb 2,640 lb FM Specification Tested for 1-1/2" to 4" pipe sizes using no hub cast iron pipe. Load ratings for Sch 10 may also be applied to AS 1074 Medium, 68/1 3091, EN 10255 Medium or Heavy), and JLS 63452 pipe. Load ratings for Sch 40 may also be applied to AS 1074 Heavy, GB/T 3091, EN 10255 Heavy!, and JIS 63454 pipe. Load ratings for FM approved lightwall may also be applied to AS 1076 Lightwall, EN 10255 L, EN 10220, and 6811 8163 pipe. FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVerit's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent 's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2019 nVent All rights reserved nVent, nVent CADDY, nVent ERICO, nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice. nnt r7jr-r.n Meets requirements of the Buy American Act Universal design allows one product to attach directly to concrete, wood, bar joist or I-beam adapters Integrated angle gauge easily displays brace member angle of installation Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1 through 2" brace pipes to reduce inventory Low profile minimizes prying effect on concrete fasteners Meets NFPA® 13 as pre-qualified for seismic applications FM® Specification Tested / HzH Material: Steel Steel Finish: Electrogalvanized <> OSHPD APPROVED Part Number Hole Size Width Thickness A B C 0 E UL Listed HS T Load CSBU1 1/2 1 15/16 3/16 21/16 1 5/16 1 3/8" 1 1/4 13/4" 3,000 lb CSBU2 13/16' 1 1/16' 3/16" 2 1/16' 1 5/16" 13/8' 1 1/4" 13/4" 3,000 lb FM Loads Part Number Brace Member Horizontal Capacity per Installation Angle from Vertical 30o -440 50 -59° 45o -59o 60o -740 75o -90o CSBU1sx Schedule 40 Pipe 1,690 lb 2,210 lb 2,660 lb 3,090 lb 1" EMT Conduit 530 Lb 9111b 11081b 1223 lb 1" Rigid Conduit 1,690 lb 2,210 to 2,660 lb 3,090 lb CSBU2xx Schedule 40 Pipe 1,480 lb 2,290 to 2,860 lb 3,090 lb 1' EMT Conduit 53011b 911 Lb 11081b 1223 lb 1' Rigid Conduit 1,480 lb 2,290 lb 2,860 lb 3,090 lb n'slent CADOY FM is registered certification murk of FM Approvals LLC, LTD. NFPA is registered trademark of National Fire Protection Association. Inc. UL, UP, cUL, cUR, cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVents product instruction sheets and training materials. instruction sheets are available at www.erico.com and from your nVent customer service representative. improper installation, misuse, misapplication or other failure to completely follow nVent 's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2019 nVent All rights reserved nVent, nVent CADDY, nVent ERICO. nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. Alt other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice. VSR (DPOTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2' DNSO VSR-2 1144402 2 1/2 DN65 VSR-2 1/2 1144425 3' DNSO VSR-3 1144403 3 1/2 - VSR-3 1/2 1144435 DNIOO VSR-4 1144404 - VSR-5 1144405 DN150 VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 UL, CUL and CSFM Listed, FM Approved, LPCBApproved,For CE Marked (EN12259-5) /VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR)-UL Flow Sensitivity Range for Signal: 4-10 GPM(15-38LPM)-UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive l0mAnipsmin. at24VDC Conduit Entrances: Two knockouts provided for 1/2' conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/1P54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-1 3 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. I CAUTUON I Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Important: This document contains important information on the installation and operation of the VSR waterfiow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. General Information Enclosure The Model VSR is a vane type waterfiow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems. it is UL Listed for use on a steel pipe; schedules 5 through 40, die-cast housing. The cover is held in place with two tamper resistant sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; screws which require a special key for removal. A field installable schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC cover tamper switch is available as an option which may be used approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering to indicate unauthorized removal of the cover. See bulletin number Information chart. 5401103 for installation instructions of this switch. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTEDINUSA MFG. #5401146- REV M PAGE! 0F4 11115 VSR (DPOTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6' (15 cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a stow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If an alarm is not desired, a qualified technician should disable the alarm system. DO NOT LEA VE COVER OFF FOR Retard Adjustment Fig. 1 AN EXTENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from ;ji L 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms TIGHTEN NUTS ALTERNATELY 'm MOUNT ON PIPE SO ARROW ON SADDLE I POINTS IN DIRECTION OFWATERFLOW CAUTION -Tote must be drilled perpendicular to the pipe and vertically centered Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect 3 (3 © (3 DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW (Flowing Waler ad/vales device in one di eec/ion only) 11wa 1146-Il in 50mm ADAPTER ADAPTER - j- 20mm ±2mm MAX. DN5O ONLY USE (2) 5180162 ADAPTERS As SHOWN ABOVE OWCO 1146. IF Compatible Installation Requirements _Pipe/ Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness ____________- Hole Size U-Bolt Nuts Torque Lightwall Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-rn VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 125+125/- .062 33.0±2.0 VSR-2 1/2 2.5 - 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - VSR-2 1/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 2,6 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00±125 50.8±2.0 20 27 VSR-3 1/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DN150 6.625 1 168.3 1 .115 2.921 0.134 3.40 0.280 7.11 0,197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 1 219.1 - - 0.148 3.76 0.322 8.18 0.248 6.3 1 0.177 1 4.5 NOTE: For copper or plastic pipe use Model VSR-.F. PRINTED IN USA MFG. #5401146 - REV M PAGE 2 OF 4 11115 Fig. 7 GREEN GROuND (E)POTTER VSR The Symbol of Protection ALARM SWITCH WITH RETARD Fig. 2 Fig. 3 To remove knockouts: Place screwdriver at Break out thin section of cover when inside edge of knockouts, not in the center, wiring both switches from one conduit entrance. Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 4 Switch Terminal Connections Clamping Plate Terminal D.G. 0,00 06 00 fo 01146-16 WARNING uninsulated section of a single conductor should not be looped md the terminal and serve as two separate connections. The must be severed, thereby providing supervision of the nection in the event that the wire become dislodged from under terminal. Failure to sever the wire may render the device Derable risking severe property damage and loss of life. not strip wire beyond 3/8" of length or expose an uninsulated ductor beyond the edge of the terminal block. When using nded wire, capture all strands under the clamping plate. Fig. 5 Typical Electrical Connections NEUTRAL FROM BREAKER I) BREAKER Notes: LINE FR The Model VSR has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. For supervised circuits, see "Switch Terminal Connections" drawing and warning note (Fig. 4). NEUTRAL FROM BELL EOL (End Of Line Resists,) onnecUng to a UL Listed panel, use the panels Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LP.M) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 6 Mounting Dimensions 3.50 it, 2.00 (50.8 DWG. 1,0514 NOMINAL PIPE OJA. +1.75 it, (+44.5 MM) FOR ON 50-ONUS 2-2.5 is NOMINAL PIPE NA. +2.125 its (+54,0 MM) FOR ON NA - ON 200 3-8 its PRINTED IN USA MFG. #5401146- REV M PAGE 3 OF 4 11/IS VSR (E)POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 8) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterflow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. Reconnect all wires. Perform a flow test and place the system back in service. Fig 8 REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH _—Z ASSEMBLY TO BASE BREAK OUTTHIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING CREWS RETARD/SWITCH ASSEMBLY / In (2) LOCATING PINS fl i DO NOT REMO (2) RETARD HOE SCREWS (2) LOCATI? BOSSES IN DWG# 1146-10 Removal of Waterfiow Switch To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. #5401146 - REV M PAGE 4 OF 4 11115 PBA-AC & MBA-DC <~> 0APPROVED (E)POTTER The Symbol of Protection Features Listed for indoor and outdoor use Outdoor use requires BBK-1 or HC-BB weatherproof back box Indoor use mounts directly to standard 4" box Low current draw High dB output AC and DC models DC models are motor driven, polarized, and have built in transient protection for supervised alarm circuits Available in 6", 8" and 10" sizes * ULC on MBA-DC Only Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (10 1mm) square electrical box for indoor use or on a model 1313K-1 or HC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- I or HC-13B, Stock No. 1500001. Notes Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is .30° to 150°F (-34° to 66°C) Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at lO ft. (3m)(2) Minimum dB at 10 ft. (3m)(l) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10(250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750150 .06A 91 79 10(250) 24VDC MBA-l0-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .1 7A 91 78 8(200) 24VAC PBA248 1808024* 17A,, 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120 VAC PBA1206 1806120* .05A 83 8(200) I2OVAC PBAl208 1808120* .05A JE92 E 84 10(250) 120VAC PBAI2OIO 1810120* .05A 86 Technical Specifications Dimensions 6" (150mm), 8" (200mm) and 10" (250mm) Cover: Steel Finish: Red Powder Coat Enclosure Base: non-corrosive composite material All parts have corrosion resistant finishes Model BBK-1 or HC-BB weatherproof backbox (optional) 24VAC Voltages Available 120 VAC I2VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Indoor or outdoor use (See Note I) Environmental -400 to 150°F (400 to 66°C) Limitations - (Outdoor use requires weatherproof backbox.) AC Bells -4 No. 18 AWG stranded wires Termination DC Bells - Terminal snip Service Use NFPA 13, 72, local AFIJ *Specifications subject to change without notice. I!ATL1 ;ii IIC Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. A WARNING In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 5400776- REV Z • 11/17 PAGE 1 OF 2 Bell Dimension Inches (mm) Fig 1 3 3/8" 5' (86mm) (127mm) I '1 DWGS 776.1 10" (250 nun) I (200 mm) 6" (150 mm) H 211/16" (68 mm) Wiring Rear View Fig 3 V3 3/8" (86 mm) 4 /4" (1016 mm) (E)POTTER The Symbol of Protection PBA -A C & MBA-DC Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Weatherproof Backbox Dimensions aIWARNING Inches (mm) Failure to install striker down will prevent bell from ringing. MODEL BBK-1 OR HC-BB Fig 2 D.C. BELLS (OBSERVE POLARITY) RED (IN) RED (OUT) - OR END-OF-LINE OR OR FROM CONTROL PANEL TO NEXT BELL FROM CONTROL PANEL PRECEDING BELL RESISTOR PRECEDING BELL DO ______________ LACK (OUT) BLACK (IN) A.C. BELLS WHITE (IN) WHITE (OUT) BLACK (IN) °Y BLACK (OUT) CAUTIO WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN, NOTES: OBSERVE POLARITY TO RING D.C. BELLS. RED WIRES POSITIVE (). BLACK WIRES NEGATIVE (-). EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. CAUTION WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 5400776- REV Z • 11/17 PAGE 2OF2 Contractor's Material and Test Certificate for Aboveground Piping Procedure: Upon completion of work, Inspection and tests shall be made by the contractor's representative and witnessed by an owners representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property Name: Olivenhan Municipal Water District Property Address: 1966 Olivenhain Rd., Encinitas, CA 92024_'8-11-2020 Accepted by Approving Authorities (Names): Carlsbad Fire Department Address: 1635 Faraday Ave., Carlsbad, CA 92008 Plans Installation conforms to accepted plans: [] Yes 0 No Equipment use is approved: E1 Yes U No If no, explain deviations: Has person in charge of fire equipment been instructed as to Yes No location of control valves and care and maintenance?: If no, explain: Instructions Have copies of the following been left on the premises?: System components instructions 0 Yes EJ No Care and maintenance instructions 0 Yes J No NFPA 25 0 Yes E1 No Location of Supplies Buildings: System Make Model Year of Office Se Quantity Tempera Mare Ratin lyco TY-FRB 2019 1/2 369 200 Sprinklers ______ Tyco RF-11 2019 lIT 270 155 EC-11 - 2019 3/4,2 286 EC-11 2019 314 5 155 Pipe and Type of Pipe: Sch, 10/30 Bull Moose Fittings Type of Fittings: Ductile Iron Threaded/ Grooved I Alarm Valve Alarm Device Maximum Time to Operate I T hrough Test Connection or Flow Type I Make Model I Mm I Sec Indicator Flow Switch System Sensor WFDON • o 40 * Dray Valve Q.O.D. Make Model Serial # Make I Model Serial # Dry Pipe Time to Trip Through Water Air Trip Point Time Water Reach l8jarm Operated Operating Test Connection - Pressure Pressure I Air Press. __jOutlet Properly? Test Mm Sec PSI PSI PSI Mm Sec Yes T No Wffh t Q.O.D. With Q.O.D. Operation: 0 Pneumatic 0 Electric . 0 Hydraulic Piping Supervised? 0 Yes 0 No Detecting Media Supervised? 0 Yes 0 No Deluge and Does valve operate from the manual trip, remote, or both control stations? 0 Yes 0 No Preaction Is there an accessible facility in each circuit for testing? Li Yes ONo Valves If no, explain: -.,--,--- perateach 1 Each Circuit O ] E CiiiIFOperatef"Maximum- .. Time to Make Model Supv. Loss Alarm? I Valve Release? _J_,,perate Release Yes No Yes No Mm Sec 0 0i 9O Pressure Location & Make & setting Pressure L .Static Pressure 'Residual (FI ow Rate Reducing Floor _Model _Left (p) Outlet (pj) Inlet(p[outlet (p Flow (g) Valve Test 1 Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for 2 hours or 50 psi (3.4 bars) above static pressure in excess of 150 psi (10.2 bars) for hours. Differential dry-pipe valve Test clappers shall be left open during the test to prevent damage. All aboveground leakage shall be stopped. Description Pneumatic: Establish 40 psi (2.7 bars) air pressure and measure drop, which shall not exceed 1 1/2 psi (0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, _which _shall _not exceed 1 %_ psi _(0.1_ bars) _in 24 hours. All piping hydrostatically tested at 12L _psi bars for 2 hrs if no, state reason: Dry piping pneumatically tested 0 Yes 0 No Equipment operates properly 0 Yes 0 No Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? E Yes 0 No Drain Test Residual pressure with valve test in I Reading of gauge located near water Tests j_supply test connection: nj_psiL_bars) [connection open wide: j.QL. psi (.bars) Underground mains and lead in connections to system risers flushed before connection made to sprinkler piping: Verified by copy of the U-Form No. 85B 0 Yes o No Other (explain): Flushed by installer of underground sprinkler piping 0 Yes 0 No If powder-driven fasteners are used in concrete, has representative If no, explain: sample testing been satisfactorily completed? 0 Yes 0 No Blank Number Used Locations Number Removed Testing a Gaskets Welded Piping? DYes IJ No If yes: bo you certify as the sprinkler contractor that welcthg procedures complWthe requirements of at least AWS 010.9, Level AR-3? 0 Yes 0 No Welding bo you certi Ttiffhe wiFd wasperforrnedb alie ncom lance with the requirements ol at least AWS 010.9, Level AR-3? 0 Yes No was carried out in compliance ocumentedqualtycontrolprocedure_to ensure that all discs are retrieved, that openings in piping are smooth, that slag and other welding residue isremoved,andthat theinternaldiametersof j i ingarenot penetrated? LJ Yes 0_No Cutouts Do you certify that you have a control feature to ensure that all cutouts (discs) are retrieved? (Discs) 92 Yes 0 No Hydraulic Nameplate provid10YeSUNofflo, explain: . Data Nameplate Date left in service wit 1 control valves open: Remarks 1 8-11-2020 Name of Sprinkler Contractor: HamiltonFireProtection Test DATE Witnessed ropertO d) TITLE By TITLE DATE President ________ .......................................... 8-11-2020 Additional Explanation and otes: Revised: 2013-May-02 Building Inspections Forms and Handouts Page 2 of 2