HomeMy WebLinkAbout2 LEGOLAND DR; ; FPC2017-0237; PermitPERMIT REPORT (b of C arlsb ty ad Print Date: 12/02/2020 Permit No: FPC2017-0237 Job Address: 2 LEGOLAND DR, CARLSBAD, CA 92008-4610 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2111000900 Track #: Valuation: $20,067,590.84 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: LEGOLAND HOTEL CALIFORNIA II AKA LLC H20 Description: PLAN REVISION: LEGOLAND HOTEL II -FIRE ALARM Fire Alarm Applied: 08/16/2017 Issued: 08/29/2017 DEV2016-0026 Finaled Close Out: 12/02/2020 Inspector: Final Inspection: FPContractor: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO, CA 92029-1924 (760) 747-3050 FEE AMOUNT FIRE New Alarm System $1,227.00 FIRE Reinspection (per inspection) $187.00 Total Fees: $1,414.00 Total Payments To Date: $1,414.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov Monitor Modules with FlashScan® by Honeywell FZM.1 (A) & FDM.1 (A) 14M.1 (A), FMM.101(A), (a NOTIFIER® J=:PC2.01+v 097P0 [2f General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1 (A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM.1 (A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- FMM-1(A) (Type H) open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:E • 07/30/2015 - Page 1 of 4 Fiiiivil 01(A) Mini Monitor Module Temperature range: 32°F to 120°F (0°C to 49°C). Built-in type identification automatically identifies this Humidity range: 10% to 93% noncondensing. rlo,,irncrflnn ift,r rnridi In +r, tha n,,n ,Jc,vI,_.c;cio a ,,,ji,ut,j, II IcJ,.JWIc; 3.) II I IJaIII.)I. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. 14 0 1 ADDRESS I 0 1 13 2 ______ 11 4 0~~ LOOP 10 ______ 987 6 87 TENS ONES I— o W (_) uJ >- U_ H The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-1 01(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max.. (Communicating, IDCShorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6' (15.24 cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on FlashScan loops, 01 - 99 on CLIP loops. LED flashes during normal operation; this is a program- mable option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Page 2 of 4— DN-6720:E .07/30/2015 Humidity range: 10% to 93% noncondensing. Agency Listings and Approvals Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x In some cases, certain modules may not be listed by certain 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x approval agencies, or listing may be in process. Consult fac- 2.125" (5.398 cm) deep box. tory for latest listing status. FDM..1 (A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY Style 0 (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, orB only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. UL: S635. ULC: S635. FM Approved. CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. MEA: 457-99-E. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). Fire Dept. of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1 (A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51253. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. DN-6720:E 07/30/2015 - Page 3 of 4 FlashScan® and NOTIFIER® are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I So 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENSINEERINS &MNQFRCflRINC All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 4 of 4— DN-6720:E .07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XPIO-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS FPC20I 7-0237 2LEGOLLND DR li LLC H20 ONE LEGOLAND DRIVE CARLSBAD, CALIFORNIA 92008 FIRE ALARM SYSTEM P.RODUCT DATA SUBMITTAL w A FIRE ALARM SYSTEM BILL OF MATERIALS MANUFACTURER DESCRIPTION CSFM# NOTIFIER NFS2-3030 FIRE ALARM CONTROL UNIT 7165-0028:0224 NOTIFIER AMPS-24 POWER SUPPLY 7165-0028:0224 NOTIFIER NCM-W NETWORK CONTROL MODULE 7165-0028:0224 NOTIFIER LCM-320 LOOP CONTROL MODULE 7165-0028:0224 NOTIFIER LEM-320 LOOP EXPANDER MODULE 7165-0028:0224 NOTIFIER LCD-160 ANNUNCIATOR 7120-0028:0227 NOTIFIER FCPS-2456/8 REMOTE NAC POWER SUPPLY 7315-0028:0225 NOTIFIER NBG-12LX, BNG-12LOB PULL STATIONS 7150-0028:0199 NOTIFIER FSP-851 ADDRESSABLE SMOKE DETECTOR 7272-0028:0206 NOTIFIER FST-851 ADDRESSABLE HEAT DETECTORS 7270-0028:0196 NOTIFIER FCO-851 SMOKE/CO DETECTOR 7275-0028:0264 NOTIFIER FMM-101 MONITOR MODULE 7300-0028:0219 NOTIFIER FRM-1 & FCM-1 ADDRESSABLE CONTROL / RELAY MODULE 7300-0028:0219 SYSTEM SENSOR DRN DUCT DETCTOR HOUSING 3242-1653:0209 SYSTEM SENSOR PC2WL/P2WL CEILING AND WALL HORN STROBES 7135-1653:0503 SYSTEM SENSOR HRK HORNS 7125-1653:0188 SYSTEM SENSOR SCWL/SWL CEILINGAND WALL MOUNTED STROBES 7125-1653:0504 SYSTEM SENSOR SWK WALL MOUNTED WEATHERPROOF STROBES 7300-1653:0187 SYSTEMS SENSOR B200S-LF LOW FREQUENCY SOUNDER 7135-1653:0213 POTTER PSNI060 REMOTE NAC POWER SUPPLY 7315-0328:0189 if 4 aasaaaa,JjM, DN-7070:N • A-la rA N FS2-3030 Intelligent Addressable Fire Alarm System General The NFS2-3030 is an intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these appli- cations. The NFS2-3030 is part of the ONYX® Series of prod- ucts from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is config- ured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelli- gent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030's large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situa- tion, fire progression, and evacuation details. A host of other options are available, including single- or multi- channel voice; firefighter's telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection prod- ucts for challenging environments; wireless fire protection; and many additional options. Features Certified for seismic applications when used with the appro- priate seismic mounting kit. Approved for Marine applications when a marine-listed ver- sion is used with marine-listed compatible equipment. See DN-60688. Complies with UL 2572 Mass Notification Systems (NFS2- 3030 version 20 or higher). One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6or7. Wireless fire protection using SWIFT Smart Wireless Inte- grated Fire Technology. See DN-60820. Up to 159 detectors and 159 modules per SLC; 318 devices per loop/3,180 per FACP or network node. - Detectors can be any mix of ion, photo, thermal, or multi- sensor; wireless detectors are available for use with the FWSG. - Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG. Large 16 line, 640 character LCD backlit display or use display-less as a network node. Network options: — High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). — Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online/offline program option. NOTIFIER® by Honeywell NFS2-3030 (left) and NFS2-3030 with DVC audio option (right) With built-in Degraded Mode operation, the system is capa- ble of general alarm if a fire alarm condition is present even if the central processing unit (CPU) fails. Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week. EIA-485 annunciators, including custom graphics. History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. Advanced history filters allow sorting by event, time, date, or address. Alarm Verification selection per point, with automatic counter. Autoprogramming and Walk Test reports. Multiple central station communication options: — Standard UDACT — Internet — Internet/GSM Positive Alarm Sequence (PAS) Presignal. Silence Inhibit and Auto Silence timer options. Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Up to 1000 powerful Boolean logic equations. Supports SCS Series smoke control system in both HVAC and FSCS modes. FM6320 approved Gas Detection System with FMM-4-20 module and any FM listed gas detector. EIA-232 printer port. EIA-485 annunciator port. DN-7070:N • 01/25/2016 - Page 1 of 8 640-CHARACTER DISPLAY FEATURES Backlit, 640-character display. Program keypad: full QWERTY keypad. Up to nine users, each with a password and selectable access levels. 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Secu- rity; Supervisory; System Trouble; Other Event; Signals Silenced; Point Disabled; CPU Failure; Controls Active. Membrane Switch Controls: Acknowledge; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 640 characters (16 lines x 40 characters) with long-life LED backlight. FLASHSCAIIA INTELLIGENT FEATURES Polls up to 318 devices on each loop in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - up to nine levels. Pre-alarm ONYX intelligent sensing - up to nine levels. Sensitivity levels: - Ion —0.5 to 2.5%/foot obscuration. - Photo - 0.5 to 2.35%/foot obscuration. - Laser (VIEW) - 0.02 to 2.0%/foot obscuration. - Acclimate Plus —0.5 to 4.0%/foot obscuration. - IntelliQuad - 1.0 to 4.0%/foot obscuration. - lnteIliQuad PLUS - 1.0 to 4.0%/foot obscuration Drift compensation (U.S. Patent 5,764,142). Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. Programmable activation of sounder/relay bases during alarm or pre-alarm. Read Status displays the level of detector cleanliness. FSL-751 VIEv (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the fire location. Early warning performance comparable to the best aspira- tion systems at a fraction of the lifetime cost. A It Sample System Options SLC Intelligent Loop H::II:II:r Upto32 LCD-160 LCD2-80 remote displays EIA-485 DEVICES FWSG FAPT-851 NBG-12LX T XP6I10 I/O Modules FSL-751 FSP-851 FMM-1 FRM-1 FSA8000 etc. IDC Relay Contact SMA CPU2-3030D display or CPU2-3030ND =-'=:a =;,= 1:0 1 H EIA-485 3072 annunciator/control points 4-111111 M ACM-8R ACM/AEM-24AT LDM-32 Relay Control LED Annunciator Custom Graphics Dual phone lines to Optional 2048-point UDACT Central Station ElA-232 III I I NFS2-3030 DVC-EM audio in CA-1 in second tier Shown in CAB-C4 with display PRN Series Printer NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal mode, but not both at the same time. Page 2 of 8— DN-7070:N • 01/25/2016 FAPT-851 ACCLIMATE PLUS Low-PROFILE INTELLIGENT • Hard-wired voice control module options. MULTI-SENSOR Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. Low-temperature signal at 40°F ± 5°F (4.44°C ± 2.77°C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. INTELLIGENT FAASTO DETECTORS FSA-5000, FSA-8000, AND FSA-20000 Connects directly to the SLC loop of compatible ONYX series panels. Provides five event thresholds that can be individually pro- grammed with descriptive labels for control-by-event pro- gramming; uses five detector addresses. Uses patented particle separator and field-replaceable filter to remove contaminants. Advanced algorithms reject common nuisance conditions FSA-5000 covers 5,000 square feet through one pipe. FSA-8000 covers 8,000 square feet through one pipe. FSA-20000 covers 28,800 square feet through one to four pipes. FCO-851 INTELLIQUAD PLUS ADVANCED MULTI-CRITERIA FIREJCO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. FMM-4-20 GAS DETECTION MODULE Interlace to industry-standard linear scale 4-20 mA sensors. Five programmable thresholds. FM Approved, Class 6320 (Stationary Gas Sensors! Detectors). SWIFT WIRELESS Self-healing mesh wireless protocol. Each SWIFT Gateway supports up to 50 devices: 1 wire- less gateway and up to 49 SWIFT devices. Up to 4 wireless gateways can be installed with overlapping network coverage. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). VOICE AND TELEPHONE FEATURES Up to eight channels of digital audio. 35 watt, 50 watt, 75 watt, and 100!125 watt digital amplifiers (DAA2/DAX series and DS series). Solid state message generation. Firefighter telephone option. 30- to 120-watt analog amplifiers (AA Series). Backup tone generator and amplifier option. FlashScan® Exclusive World-Leading Detector Protocol At the heart of the NFS2-3030 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). Flash- Scan is an all-digital protocol that gives superior precision and high noise immunity. As well as giving quick identification of an active input device, this protocol can also activate many output devices in a frac- tion of the time required by competitive protocols. This high speed also allows the NFS2-3030 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan® detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing ONYX Intelligent Sensing is a set of software algorithms that provide the NFS2-3030 with industry-leading smoke detection capability. These complex algorithms require many calcula- tions on each reading of each detector, and are made possible by the very high-speed microcomputer used by the NFS2- 3030. Drift Compensation and Smoothing. Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, usually caused by electrical interference. Maintenance Warnings. When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust. Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control func- tions. Self-Optimizing Pre-Alarm. Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing. A patented feature of ONYX Intelligent Sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. DN-7070:N • 01/25/2016 - Page 3 of 8 Field Programming Options Autoprogram is a timesaving feature. The FACP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installa- tion, even if only a portion of the detectors are installed. Keypad Program Edit. The NFS2-3030, like all NOTIFIER intelligent panels, has the exclusive feature of program cre- ation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS2-3030 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS2-3030 simultaneously monitors other (already installed) points for alarm conditions. VERiFlRe TOOLS VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Win- dows® based and provides technologically advanced capabili- ties to aid the installer. The installer may create the entire program for the NFS2-3030 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Product Line Information "Configuration Guidelines" on page 4 "Main System Components" on page 4 "Networking Options" on page 4 "Auxiliary Power Supplies and Batteries" on page 4 "Audio Options" on page 5 "Compatible Devices, EIA-232 Ports" on page 5 "Compatible Devices, EIA-485 Ports" on page 5 "Compatible Intelligent Devices" on page 5 "Enclosures, Chassis, and Dress Plates" on page 6 "Other Options" on page 7 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On single-FACP systems (one NFS2-3030D), the display option is the CPU2-30300. On network systems (two or more net- worked fire panel nodes), at least one NCA-2, NCS, or ONYX- Works annunciation device is required. Options listed as follows. MAIN SYSTEM COMPONENTS ;cPu2-3o3oD: NFS2-3030 Primary Display. CPU2-30306 ships with keypad/display installed; includes 640-character , backlit LCD display, OWERTY programming and control key- Ipad. CPU2-3030 is a central processing unit and requires an AMPS-24(E) power supply. Non-English versions are avail- able: CPU2-3030D-FR, CPU2-3030D-HE, CPU2-3030D-KO, CPU2-3030D-PO, CPU2-3030D-SC, CPU2-3030D-SP, CPU2- 3030D-TC, and CPU2-3030D-TH. For English Marine applica- tions order CPU2-3030D-M; for non-English Marine applica- tions order CPU2-3030D-M and the appropriate KP-KIT-XX. (See DN-60688.) CPU2-3030ND: CPU2-3030 without display. Non-English ver- sions are available: CPU2-3030ND-FR, CPU2-3030ND-HE, CPU2-3030ND-KO, CPU2-3030ND-PO, CPU2-3030ND-SC, CPU2-3030ND-SP, CPU2-3030ND-TC. LCM-320: Loop Control Module. Provides one SLC. NFS2- 3030 supports up to five LCM-320s and five LEM-320 expand- ers for a total of ten SLCs. See DN-6881. LEM-320: Loop Expander Module. Expands an LCM-320. See DN-6881. SAMPLE SYSTEM: Four-loop NFS2-3030 with display: CPU2-3030D, DP-DlSP; two BMP-1s, CHS-1143, two LCM- 320s, two LEM-3205, AMPS-24, SBB-A4, DR-A4, BP24, BB- 100, batteries. NETWORKING OPTIONS NCA-2: Network Control Annunciator, 640 characters. An alternate primary display for CPU2-3030 can be provided by the NCA-2, NCS, or ONYXWorks. Using NCA-2 as primary display enables non-English languages. On network systems (two or more networked fire panel nodes), one network display (either NCA-2, NCS, or ONYXWorks) is required for every sys- tem. On network systems, the NCA-2 connects (and requires) a standard Network Communication Module or High-Speed Network Communication Module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP-DISP, ADP-413, or in an annunciator box, such as the ABS-2D. In CAB-4 top-row applications, a DP-DISP and two BMP-1 blank modules are required for mounting. Non-English versions are available: NCA-2-FR, NCA-2-HE, NCA-2-KO, NCA-2-PO, NCA-2-SC, NCA-2-SP, NCA-2-TC, NCA-2-TH. For marine applications, order NCA-2-M; for non-English marine applications order NCA-2-M and appropriate KP-KIT-XX. See DN-7047. NCM-W, NCM-F: Standard Network Communications Mod- ules. Wire and multi-mode fiber versions available. See DN- 686 1. HS-NCM-W/MF/SFIWMF/WSF/MFSF: High-speed Network Communications Modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conver- sion models are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN- 697 1. ONYXWorks: UL-listed graphics PC workstation, ONYX- Works GUI software, and computer hardware. See DN-7048 for specific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN- GW-EM.) See DN-60499. NWS-3: NOTI-FIRE*NETTm Web Server. See DN-6928. CAP-GW: Common Alerting Protocol Gateway. See DN- 60756. VESDA-HLI-GW: VESDAnet high-level interface gateway. See DN-60753. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOTI•FIRE.NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See DN-60679. AUXILIARY POWER SUPPLIES AND BATTERIES AMPS-24(E): One required for each NFS2-3030. Addressable power supply and battery charger with two 24 VDC outputs. Addressable by any FlashScan® or CLIP mode FACP. Charges 7 to 200 AH batteries. Occupies up to five addresses on an SLC, depending on configuration. Primary input power for panel. See DN-6883. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See ON- 5952. Page 4 of 8— DN-7070:N • 01/25/2016 ACPS-610: 6.0 A or 10.0 A addressable charging power sup- ply. See DN-60244. FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with battery charger. See DN-6927. BAT Series: Batteries. AMPS-24 uses two 12 volt, 7 to 200 AH batteries. See DN-6933. AuDio OPTIONS NOTE: See "Enclosures, Chassis, and Dress Plates" on page 6 for mounting hardware. DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display. See DN- 60726. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC-EM while retaining digital audio distribuition capabilities. Can be configured with up to four DS- AMPs, supplying high-level risers spread throughout an instal- lation. See DN-60565. DVC-KD: DVC-EM keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons. See DN- 7045. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC-EM, DS-DB distribution board, and DAA2/DAX Series amplifiers. See DN-60633. DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- bly with power supply; includes chassis. See DN-60556. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See ON- 60556. DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. TELH-1: Firefighter's Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis. See DN-7045. CMIC-1: Microphone used with DVC/DVC-EM. Included with CA-2 chassis assembly. See DN-7045. RM-1/RM-ISA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RMI-RMR (RM-1SA) stand-alone cabinets. See DN-6 728. AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier and audio input supervision, backup input, and automatic swi- tchover, power supply, cables. See DN-3224. AA-I20IAA-100: Audio Amplifier. AA-120 is 120 watts, 25 Vrms. AA-100 is 100 watts, 70.7 Vrms. The amplifier contains an integral chassis for mounting to a CAB-134, -C4, or -D4 backbox (consumes one row). Includes audio input and ampli- fied output supervision, backup input, and automatic switcho- ver to backup tone. See DN-3224. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running SR4.0. For specific information on DAA-50 series amplifiers, refer to DN-7046. For information on DAA-7525 Series, refer to DN- 60257. COMPATIBLE DEVICES, EIA-232 PORTS PRN-6: 80-column printer. See DN-6956. PRN-7: 80-column printer. See DN-60897 VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACP5 and/or peripherals. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24A1: Same LED and switch capabilities as ACM-24AT; expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active! Alarm LEDs can be programmed (by powered-up switch selection) in groups of 24 to be red, green, or yellow. Expand- able to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A; expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. LCD-160: Liquid Crystal Display annunciator, 160-character backlit. Can store character sets for multiple languages. Sup- ports Canadian requirements. See DN-6940. LCD2-80: Terminal and ACS mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See LCD2-80 (DN-60548). SCS Series: Smoke control station; eight (expandable to 16) circuits. See DN-4818. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (as in single-address mode applications) or in CHS- M3 position. See DN-6860, UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides pos- itive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from IBM -compatiblePCs (requires optional programming kit). Mounts on a CHS-4 series chassis within NFS2-3030. COMPATIBLE INTELLIGENT DEVICES FWSG Wireless SWIFT Gateway: Addressable gateway sup- ports wireless SLC devices. Not appropriate for ULC applica- tions. See DN-60820. FSA-5000: Intelligent FAAST® XS Fire Alarm Aspiration Sens- ing Technology. Intelligent aspirating smoke detector for appli- cations up to 5,000 sq.ft. For Canadian applications, order FSA-5000A. FSA-8000: Intelligent FAAST® XM Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 8,000 sq.ft. For Canadian applications, order FSA-8000A. See DN-60792. DN-7070:N • 01/25/2016 - Page 5 of 8 FSA-20000: Intelligent FAAST® XT Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 28,800 sq.ft. For Canadian applications, order FSA-20000A. See DN-60849. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-200S: Intelligent beam smoke detector with integral sen- sitivity test. See DN-6985. FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria Detector. See DN-60412. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Crite- ria Fire/CO Detector. See DN-60689. FSI-851: Low-profile FlashScan ionization detector. See ON- 6985. FSP-851: Low-profile FlashScan photoelectric detector. See DN-6935. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNR(\. See ON-6935. FSP-851T: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FST-851: FlashScan thermal detector 135°F (57°C). See ON- 6936. FST-851R: FlashScan thermal detector 135°F (57°C) with rate-of-rise. See ON-6936. FST-851H: FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. FAPT-851: FlashScan Acclimate Plus low-profile multi-sen- sor detector. See DN-6937. FSL-751: FlashScan VIEW® laser photo detector. See ON- 6886. DNR: InnovairFIex low-flow non-relay duct-detector housing (order FSP-851 separately). Replaces FSD-751 PL/FSD- 751 RPL. See ON-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. B224B1: Isolator base for low-profile detectors. See ON- 60054. B2IOLP: Low-profile base. Standard U.S. style. Replaces B7IOLP. See DN-60054. B501: European-style, 4(10.16cm) base. See ON-60054. B200S: Intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. B200S-LF: Low-frequency version of B200S. See DN-60054. B200SCOA: Based on B200SA, with added CO detector markings in English/French. For Canadian applications only. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. B200SR-LF: Low-frequency version of B200SR. See DN- 60054. FMM-1: FlashScan monitor module. See DN-6 720. FDM-1: FlashScan dual monitor module. See DN-6 720. FZM-I: FlashScan two-wire detector monitor module. See DN-6720. FMM-10I: FlashScan miniature monitor module. See ON- 6 720. FMM-4-20: FlashScan 4-20 mA protocol monitor module. See DN-60411. FCM-1: FlashScan control module. See DN-6724. FCM-1-REL: FlashScan releasing control module. See DN- 60390. FTM-I: Firephone Telephone Module connects a remote fire- fighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is supervised. See ON-6989. FRM-1: FlashScan relay module. See ON-6724. FDRM-1: FlashScan dual monitor/dual relay module. See ON- 60709. NBG-I2LX: Manual pull station, addressable. See DN-6726. ISO-X: Isolator module. See ON-2243. ISO-6: Six Fault isolator module. For Canadian applications order ISO-6A. See DN-60844. XP6-C: FlashScan six-circuit supervised control module. See ON-6924. XP6-MA: FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See DN-6926. XPIO-M: FlashScan ten-input monitor module. See DN-6923. SLC-IM: SLC integration module, for VESDAnet detectors. See ON-60755. ENCLOSURES, CHASSIS, AND DRESS PLATES CAS-4 Series Enclosure: NFS2-3030 mounts in a standard CAB4 Series enclosure (available in four sizes, 'A" through "D"). Backbox and door ordered separately; requires BP2-4 battery plate. A trim ring option is available for semi-flush mounting. See ON-6857. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabinets are available in three sizes, "B" through "D". See ON- 60229. CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Order CPU2-3030D-M; for non- English marine applications order CPU2-3030D and appropri- ate KP-KIT-XX. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see DN-60688. CHS-M3: Mounting chassis for CPU2-3030. One required for each CPU2-3030D/3030ND. CA-2: Chassis for FACP control panel when DVC-EM is used with firefighter's telephone. Mounts in the top two rows of a CAB4 series enclosure. DP-DISP: Dress panel for top row in cabinet with CPU2- 3030D installed. DP-IB: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. See ON-7046. CHS-BHI: Battery chassis; holds two 12.0 AH batteries. Mounts on the left side of DAA2 chassis. See DN-7046. CA-I: Chassis, occupies one tier of a CAB-4 Series enclo- sure. The left side accommodates one DVC-EM and a DVC- KD (optional); and the right side houses a CMIC-1 microphone and its well (optional). See DN-7045. CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC-EM mounted on a half-chassis and one NFS2-3030 or NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMIC-1 microphone. ADDR Series doors with two-tier visibility are available for use with Page 6 of 8- DN-7070:N • 01/25/2016 the CA-2 configuration: ADDR-134, ADDR-C4, ADDR-D4 (below). ADDR-134: Two-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-134 backbox with the ADDR-134. See DN-7045, DN-6857. ADDR-C4: Three-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045, DN-6857. ADDR-D4: Four-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-7045, DN-6857. DPA-1: Dress panel, used with the CA-1 chassis when config- ured with a DVC-EM, DVC-KD, and CMIC-1. See DN-7045. DPA-2: Dress Panel used with the CA-2 chassis assembly. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-i is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. See DN- 7045. ADP4B: Annunciator dress plate. Mounts in rows 2, 3 or 4 of a CAB-4 series enclosure. Used with ACS series annuncia- tors. BMP-1: Blank module for unused module positions. DP-1B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. BP2-4: Battery plate, required. CHS41L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers. CHS4N: Chassis for mounting up to four APS-6Rs. CHS-6: Chassis used with the XP6 and XPIO Multi-Modules. Mounts up to six modules in any CAB-4 series row. BB-100: Backbox for batteries and power supplies. The BB- 100 is used to mount up to two 100 AH batteries and power supply, if needed. 30" (76.20 cm) wide x 25" (63.50 cm) high x 7.5" (19.05 cm) deep; depth includes door. BB-200: Backbox for batteries and power supplies. Holds up to four 100 AH batteries (200 AH capacity) and power supply. 30" (76.20 cm) wide x 36" (91.44 cm) high x 7.5" (19.05 cm) deep; depth includes door. NFS-LBB: Battery Box. The NFS-LBB is used to mount up to two 55 AH batteries. Dimensions: Box: 24" (610 mm) wide x 14" (356 mm) high x 7.75" (197 mm) deep. Door: 24.125" (613 mm) wide x 14.25" (362 mm) high; door adds 0.0625" (approx. 1.6 mm) to depth. BB-UZC: Backbox for housing the UZC-256 for applications where the UZC will not fit in panel enclosure. Black; for red, order BB-UZC-R. See DN-3404. SEISKIT-CAB: Seismic mounting kit. Required for seismic- certified applications with NFS2-3030 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two 26 AH batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 4IIUDAC: Digital alarm communicator. See DN-6746. IPDACT-2, IPDACT Internet Monitoring Module: Connects to primary and secondary DACT telephone output ports for internet communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-212UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: Y-adapter option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red; for black, order IPENC-B. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tor. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. For Canadian applications order IPGSM-4GC. See DH-60769. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. System Specifications SYSTEM CAPACITY Intelligent Signaling Line Circuits ...........1 expandable to 10 Intelligent detectors..........................................159 per loop Addressable monitor/control modules..............159 per loop Programmable software zones ............................. over 2000 ACS annunciators per CPU2-3030 .......................32 address x 64 or 96 points NOTE: The CPU2-3030 can support up to 96 annunciator address points per ACM-24AT/-48A. SPECIFICATIONS Primary Input Power: -AMPS-24:110-120 VAC, 50/60 Hz, 4.5A maximum. -AMPS-24E: 240 VAC, 50/60 Hz, 2.25 A maximum. DC Output: - Main 24 VDC: Up to 5.0 A - Aux 24 VDC: Up to 5.0 A -5VDC: Up to 0.15A. Current draw (Standby/Alarm): - CPU2-3030D board: 0.340 A. - CPU2-3030ND board: 0.120 A. fjCM-320: O.i3OJA. -M7320:O166A. - AMPS-24(E)": 0.13 A. (Draws power from secondary power source only.) NOTE: See AMPS-24(E) Manual 51907 for a complete current draw calculation sheet and details of input and output values. Battery charger range: 7 AH - 200 AH. Use separate cabinet for batteries over 26 AH. Float Rate: 27.6 V. SHIPPING WEIGHT CPU2-3030D: 5.95 lb (2.70 kg). CPU2-3030ND: 2.90 lb (1.32 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 - 120"F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic DN-7070:N • 01/25/2016 - Page 7 of 8 components may be adversely affected by extreme tempera- CBC 2007 (Seismic). ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27"C!60 - 80"F. AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635. ULC Listed: S635. MEA: 232-06-E. Fire Dept. of New York: COA#6114. CSFM: 7165-0028:0224 (Commercial). FM Approved. FM6320 Approved. Class 6320 for Gas Detection. City of Chicago. City of Denver. Singapore Productivity and Standards Board (PSB). CCCF listed. Fire Services Department (Hong Kong). Marine Applications: Marine approved systems must be con- figured using components itemized in this document. (See Main System Components, in "Product Line Information.) Spe- cific connections and requirements for those components are described in the installation document, PN 54756. When these requirements are followed, systems are approved by the fol- lowing agencies: US Coast Guard 161.002/55/0 (Standard 46 CFR and 161.002). Lloyds Register 11/600013 (ENV 3 category). American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. STANDARDS The NFS2-3030 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: UL 864 (Fire). UL 1076 (Burglary). UL 2572 (Mass Notification Systems). (NFS2-3030 version 20 or higher) LOCAL (Automatic, Manual, Waterilow and Sprinkler Supervisory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual, Waterfiow and Sprin- kler Supervisory). Not applicable for FM. EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- IntelliQuad, NOTI.FlRE.NET , ONYXWorks and SWIFT are all work). trademarks; and Acclimate® PIus, FlashScan, Intelligent FAAS1®, IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- NOTIFIER®, ONYX®, VenFire® Tools, and VIEW® are all registered trademarks of Honeywell International Inc. mic). 02016 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so ooi We try to keep our product information up-to-date and accurate. K33-b We cannot cover all specific applications or anticipate all requirements. MNIIrcIIIIlN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. w.notifier.com Page 8 of 8— DN-7070:N • 01/25/2016 DN-6883:B AM PS-241E Power Supply NOTIFIER 0 for the NFS..3030, NFS2.3030 and NCA-2 by Honeywell CatallogSectioril General NOTIFIER's AMPS-24/E is an addressable power supply and battery charger with up to three 24 VDC outputs. It operates in either FlashScan® or CLIP (Classic Loop Interface Protocol) mode with the NFS-3030/NFS2-3030 Fire Alarm Control Panel (FACP). It can also be used as the primary power supply for the NCA-2 Network Control Annunciator. Features Addressable by NFS-3030/NFS2-3030 FACP. Selectable charging current charges 7 AH to 200 AH batter- ies. Isolated Signaling Line Circuit (SLC) interface. Trouble bus input for use with normally-open dry contacts or open-collector circuit. USB Type B connector for programming installation param- eters. Brownout detection. Battery/battery charger supervision. Secondary Power Auxiliary Outputs: 24V @ 0.5A and 5V @ 0.15A. AC loss detection and AC loss delay reporting. Mounts in a CAB-4 Series enclosure, EQ Cabinet Series enclosure, BB-25, BB-1 00, or BB-200 Battery Backbox. Specifications Primary (AC) power: AMPS24: 110-120 VAC 50/60 Hz input, 5 A maximum; AMPS24E: 220-240 VAC 50/60 Hz input, 2.5 A maximum. MAIN 24V Output - filtered power-limited power. Refer to table for configuration/current information. charger Settingl Main 24V (TB I *Total Aux 24V (TB3 on Main Battery Size Main Control unit) Control Unit with TB2 on CPS- Max. Current 24) Max. Current 1N7-26AH Bat- 5A 3A tenes 2A112-60AH Bat- 5A 3A teries 5N55-200AH Configuration 1 5A OA Configuration 2 3A 1A Disabled 5A 5A * Maximum current for all AUX 24 volt outputs. Note that T132 on CPS-24 is limited to 0.5A. AUX 24V - provides filtered power-limited power for addi- tional components. Refer to table above for configuration/ current information. Secondary power (battery) charging circuit: Current-limited, sealed lead-acid battery charger which will charge 7 to 200 AH batteries. Selectable charging current: 1.0 A, 2.0 A or 5.0 A. Secondary power auxiliary outputs. Wire sizes: 10 AWG (5.26 mm2) to 22 AWG (0.326 mm2). Battery fuse (F2): 15 A, fast-acting. Shipping Weight: 4.25 lb Agency Listings and Approvals These listings and approvals apply to the AMPS-24/E power supply. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL: S635 ULC:C5118 City of Chicago City of Denver MEA: 345-02-E CSFM: 7165-0028:224 FM: Approved FDNY: #6026 Product Line Information Addressable power supply/battery charger, AMPS-24E: Same as AMPS-24: 220-240VAC operation DN-6883:B• 10/15/09—Page 1 012 FlashScan® is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. 93a • • We cannot cover all specific applications or anticipate all requirements. ENCIRMINS I M11114FAMRING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-6883:13 • 10/15/09 LCM-320 and LEM-320 Loop Control and Expander Modules General The LCM-320 Loop Control Module and the LEM-320 Loop Expander Module provide NOTIFIER's ONYX® Series of Fire Alarm Control Panels (FACP5) with Signaling Line Circuits (SLCs). The ONYX® Series NFS-640/NFS2-640 supports one LEM-320; the NFS-30301NF52-3030 supports up to five LCM- 320s and five LEM-320s. The LEM-320 module is used to expand the NFS-6401NF52-640 to a second loop, and to expand each LCM-320 used on the NFS-30301NF52-3030 - each NFS-3030/NFS2-3030 LCM-320 supports an expansion LEM-320. Features Up to 12,500 feet (3,810 m) on a Class B (Style 4) SLC loop (twisted-unshielded). Built-in degraded mode increases survivability. Very simple installation - plug-in style. Permits multiple loops in small enclosure. DN-6881 Al • A-35 NOTIFIER® by Honeywell Specifications Voltage: 24 VDC nominal, 27.6 VDC maximum. Maximum loop length: The maximum wiring distance of an SLC using 12 AWG (3.1 mm2) twisted-pair wire is 12,500 feet (3810 m) per channel. For a twisted-unshielded pair, 12 AWG (3.1 mm2) to 18 AWG (0.78 mm2): - Distance with 12 AWG: 12,500 It (3,810 m). - Distance with 14 AWG: 8,000 ft (2,438 m). - Distance with 16 AWG: 4,875 ft (1,486 m). - Distance with 18 AWG: 3,225 ft (983 m). —50 ohms maximum per length of Style 6 & 7 loops. —50 ohms maximum per branch for Style 4 loop. Maximum current: for LCM-320: 130 mA; for LEM-320: 100 mA; for single SLC loop: 400 mA maximum. NOTE: Maximum short circuit - loop will shut down until short-cir- cuit condition is corrected. Maximum resistance: 50 ohms (supervised and power- limited). Temperature and humidity ranges: This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F Loop Control Loop Expander Module Module Product Line Information #M -320:1 Loop Control Module. Adds SLCs to NFS-3030/ INFS2-3030; NFS-3030/NFS2-3030 supports up to five LCM-, i?Qs and five LEM-320s.) EM-320: Loop Expander Module. Expands each LCM used on the NFS-3030/NFS2-3030; expands NFS-640/NFS2-640 to two loops. Agency Listings and Approvals The listings and approvals below apply to the basic LCM-320 and LEM-320. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL: S635 ULC:S635/CS118 FM Approved CSFM: 7165-0028:224, 7170-0028:223 (LCM/LEM-320 with NFS-3030/NFS2-3030). 7165-0028:214, 7170- 0028:216 (LEM-320 with NFS-640). 7165-0028:243, 7170- 0028:244 (LEM-320 with NFS2-640). FDNY: COA#6025 (LEM-320 with NFS2-640) FDNY: COA#6026 (LCM-320/LEM-320 with NFS2-3030) City of Denver Hong Kong DN.6881:A1 ° 06/05/2009 - Page 1 of 2 FLASHSCAN® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6881 Al • 06/05/2009 DN-6861 :C • AO-260 NCM-W, NCM-F ONYX® Series Network Communications Modules General The Network Communications Module (NCM) provides NOTIFIER Intelligent Fire Alarm Control Panels, and NCA and NCA-2 Network Control Annunciators with a means to connect to NOTI. FIRE- NErM. Two types of NCM are available: NCM-W for connecting nodes with twisted-pair wire, and NCM-F for connecting nodes with fiber-optic cable. NOTE: Do not mix NCM and High Speed (HS) NCM on the same system. NCM.W Features Supports twisted-pair wire medium. NFPA Style 4 (Class B) operation or NFPA Style 7 (Class A) operation. Two programmable data thresholds. Transformer coupling provides electrical isolation between nodes. Pluggable terminal wiring with strain relief. Pluggable service connector (feeds signal directly through) in the event that power must be removed from a node. 312.5 Kbaud transmission rate. Data is regenerated at each node. Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer. Enables software and database upload/download over NOTI. FIRE* NET. Repeaters are available to increase signal. Repeaters may be utilized to switch media type. Up to 3,000 feet (914.4 m) between nodes in a point-to- point fashion (actual distance varies with wire quality). NCM-W Interconnections: When wiring consecutive NCM-W boards, wiring may enter or exit at Port A or Port B. NCM-W port-to-port wiring is not polarity sensitive; use of Port A or Port B is arbitrary. An NCM-W may be connected to any of the following devices: MIB-W, MIB-WF NAM-232W, NCM-W (in another panel), NCS-W network connection, RPT-W, APT-WE NCM-W Switch Functions: The NCM-W provides two sets of switches to simplify network setup. Enable ground fault detection by setting 'ON" switch SW1 03 (Channel A); switch SW1 01 (Channel B). Activate on-board end-of-line resistors by setting "ON" switch SW100 (Channel A); switch 102 (Chan- nel B). NOTE: Correct configuration is dependent on network design; refer to the NOTI • FIRE- NET' manual. For further information and diagrams, refer to the NCM Instal- lation Document, 51533. NCM.F Features Supports fiber-optic medium. NFPA Style 4 (Class B) or Style 7 (Class A) operation. Data is immune to all environmental noise. Optical isolation prevents ground loops. NOTI • FIRE• NETTh fiber-optic medium. Fiber type: 62.5/125 micrometers (multimode); or 50/125 micrometers (multimode). NOTIFIER® by Honeywell NCM-W Maximum attenuation is 8 dB with 62.5/125 pm fiber and 4.2 dB with 50/125 pm fiber. Wavelength (1): 820 nanometers (use standard 850 nm fiber). Connectors: ST® style. 312.5 Kbaud transmission rate. Data is regenerated at each node. Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer. Enables software and database upload/download over NOTI• FIRE- NET'M. Repeaters are available to increase signal. Repeaters may be utilized to switch media type. Up to 3,000 feet (914.4 m) between nodes in a point-to- point fashion (actual distance varies with wire quality). NCM-F Interconnections: When wiring consecutive nodes/ repeaters, fiber cable must exit one board on Transmit (TX) and enter the next node/repeater on Receive (RX). The fiber- optic pair (FIX, TX) from Port A of one node/repeater may be connected to either Port A or Port B of another node/repeater. An NCM-F may be connected to any of the following devices: MIB-F, MlB-WI NAM-23217, another NCM-F, NCS-F network connection, APT-F, APT-WE Common Specifications Temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ±2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Power supply: 24 VDC © 110 mA. DN-6861 :C • 10/04/2010 - Page 1 of 2 Mixing Wire and Fiber on the Same Network In some networks, it may be necessary to mix twisted-pair wire and fiber-optic cable. There are two solutions: In any network, an RPT-WF may be used as an interface between wire and fiber. In a network that uses an AFP1010 or AM2020, a MIB- WF may be used as the interface between wire and fiber. Mounting Both NCM-W and NCM-F can be installed in any standard chassis such as the CHS-4L, CHS-M2, CHS-M3 or CHS-4N (see panel sheets). Additionally, the NCM-W can be door- mounted on the ADP-413 dress panel on a single-space blank plate (BMP-1) for mounting in an CAB-4 Series cabinet. Agency Listings and Approvals The following listings and approvals apply to the NCM. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 ULC Listed: S635 CSFM: 7165-0028:0214, 7165-0028:0224, 7165- 0028:0243 FM approved MEA approved FDNY: COA#6061, COA#6065 Product Line Information NCM-W: Network Communications Module, twisted-pair wire nterface.i NCM-F: Network Communications Module, fiber-optic cable interface. Diagnostic LED Indicators A HI (green): Illuminates to indicate the NCM-W Port A is set for high threshold (NCM-W only). B HI (green): Illuminates to indi- cate the NCM-W Port B is set for high threshold (NCM-W only). RCD A (green): Illuminates when the NCM is receiving data from NOTI.FIRE.NETT on Port A. RCD B (green): Illuminates when the NCM is receiving data from NOTI*FIRE-NETrm on Port B. STATA (yellow): Illuminates when the NCM has not received valid data from NOTI-FIRE-NETrm on Port Afor at least 16 sec- onds. STATB (yellow): Illuminates when the NCM has not received valid data from N0T1*F1RE*NETnd on Port B for at least 16 seconds. RECON (yellow): Illuminates when a reconfiguration on NOTI-FIRE-NETrm is in progress. PULSE (green): Illumi- nates when the NCM is transmitting NOTI•FIRE.NETTh is in progress. RESET (yellow): Illuminates when the microcontroller fails. POWER (green): Illuminates when +5 VDC is available. NCM-W (detail) EFBTEPJ.IB - EFAIERMA Ground Fault Detection Switches and EO Netw IRESET End-of 11 11 LEDs Termin I LEDIGO - Resistor 11 11 BHI Switc LED7 J2 7! o RCDB LED2 0 0 0 STATS ii Ell f N PULSE1 o LED8 Diagnostic PER / I Network / Connection Ports ©© (NUP) ©© Channel A & B NCM-F (detail) Channel A & B Connections ...._- Connections J203 J20e2J20 eJ2 eo Connection M Future Use . Fiber signat intensity switch. J2 Full - standard Low - short distance 1:1 OORCOA RCDB Ell El 0 STATS STATB 1° 13 11 0 RECUR PULSE DID no RESET POWER Diagnostic Network Connection Ports (NUP) LEDs ©© ©© NOTI. FIRE• NET' is trademark of Honeywell International Inc. ONYX® and NOTIFIER® are registered trademarks of Honeywell International Inc. ST® is a registered trademark of AT&T. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. USB Connection Future Use This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. 933ME3130M We cannot cover all specific applications or anticipate all requirements. MIUMC11IIIN All specifications are subject to change without notice. OUAIITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6861 :C • 10/04/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL T - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:0224 Page 1 of 4 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Model NFS-3030, NFS-3030E, NFS2-3030, NFS2-3030E fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), automatic, manual, waterfiow and sprinkler supervisory services. Suitable for use as a releasing service, Emergency Voice/Alarm Communication System and Process/Energy Management Equipment. Refer to listees data sheet for detailed product description and operational considerations. System components: AA-30/-100/-120; Amplifiers ACM-8R/-1 6AT/-24AT/-32A/-48A; Annunciator Control Modules ACPS-610; Addressable/Charger Power Supply ACPS-2406; Addressable Charger/Power Supply ACT-1/-2/4/-25/-70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4R/-D4/-D4R; Doors AEM-i 6AT/-24AT/-32A/-48A; Annunciator Expander Modules AFM-i 6N-i 6AT/-32A; Annunciator Fixed Modules AKS-1 B; Annunciator Key Switch AMG-1/-E; Audio Message Generator AMPS-24, CPS-24; Addressable Main Power Supply APS-61R, APS2-6R; Auxiliary Power Supply ARM-4; Auxiliary Relay Module BDA-25V/-70V; Backup Digital Audio Amplifiers BGRA-SCS, BGRB-SCS, CEF-SCS, RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station BB-17/-25/-100/-200; Battery Box BMP-1; Blank Module BP-4; Battery Panel BP24; Dress Panel CA-1/-2; Chassis CAB-3/4 Series, EQ Series; Enclosures *CABRP CAB-RPR; Cabinets CHG-120; Battery Charger CHS-4U4MB/4N/-6/-M3/-PS/-BH1; Chassis CMIC-1, CMICRP*; Microphone Assembly CPU2-3030D/CPU2-3030ND; CPU Board *Rev. 05-08-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0224 Page 2 of 4 CRE-4; Control Relay Expander CRM-4RK; Control Relay Module CRT-2; Display Terminal DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-5025SF; Digital Audio Amplifiers, Fiber Mode DAA-5070F/DAA-50705F; Digital Audio Amplifiers, Fiber Mode DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-7525SF Series; Digital Audio Amplifiers DAA-PS; Power Supply DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DCM-4RK; Dual Channel Module DP-113; Blank Panel DP-DISP; Display Dress Panel DR-A4, DR-A4B, DR-A4BR, DR-A4R; Door Assembly DR-AA4, DR-M413, DR-AA4BR, DR-AA4R; Door Assembly DR-B3F; Door Assembly DR-134, DR-B4B, DR-B4BR, DR-134R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DPDW-1 B, DPSW-1 B, XPDP; Dress Panels VP-2B, DPA-1 I-I A4/-2; Dress Panels DPI-232; Direct Panel Interface DVC-AO; Digital Voice Command DVC-EM; Extended Memory DVC-EMF/DVC-EMSF; Digital Voice Command/Ext Memory DVC-KD; Keypad Board DVC-RPU; Remote Paging Unit EQBB-B4, EQBB-C4, EQBB-D4; Backbox Assembly EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1 -REL; Releasing Control Module FCPS-24S6/58; Field Charger/Power Supply FFT-7/-7S; Fire Fighter's Telephones Fl RSTVISION-LCD; Interactive Firefighters Display FIRSTVISION-ENC; FirstVision Backbox Enclosure and Door FMM-4-20; Analog Input Module FHS; Fireman's Handset FCM-1; Addressable control module FDM-1; Dual monitor module FDRM1*; Dual Relay/Monitor Module FMM-1; Monitor module FMM-101; Miniature monitor module *Rev. 05-08-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0224 Page 3 of 4 FRM-1; Addressable relay module FTM-1; Firephone Control Module FPJ; Fireman's Phone Jack FZM-1; Two-wire detector monitor module HS-NCM-W/-MF/SF/-WMF/-WSF/-MFSF; High Speed Network Control Modules ICE-4; Indicating Control Expander lCM-4RK; Indicating Circuit Module I PDACT-2/-2UD/IPENC; I P Digital Alarm Communicator ISO-X; Isolator Module lZE-A; Initiating Zone Expander lZM-8RK; Initiating Zone Module LCD-80, -160; Liquid Crystal Display Module LCD2-80; Liquid Crystal Display LCM-320; Loop Control Module LDM-32/-E32/-R32; Lamp Driver Module LEM-320; Loop Expander Module MP-113; Blank Panel MPS-2413; Power Supply Module NBG-12; Series Addressable Manual Pull Station NBG-12LX; Manual pull station, addressable. See DN-6726 NCA/NCA-2; Network Control Annunciator NCM-W/-F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station, Wire/Fiber NCSS-W-ONYX, NCSS-F-ONYX; Network Control Station, Wire/Fiber ONYXWorks-EW/-NW/NF/-HNW/-HNMF/-HNSF/-TS/-EW-TS/-NF-TS/-HW-TS/-HNMFT/ -HNSFT/- HNWr; Graphics PC workstation for NOTI-FIRE-NET Wire/Fiber/with Touch-screen monitors N-ELR; End of Line Resistors NFS-LBB/-LBBR; Battery Box PRN-6; Printer R-120/-2.2K/-27K/-470/-47K; End of Line Resistors RA-400/400Z; Remote Annunciators RKS-S; Remote Security Keyswitch RM-1/-ISA; Remote Microphone RPJ-1; Remote Paging Jack RPT-W/-F/-485W/-485WF; Repeater SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-AA4R; Backbox Assembly SBB-134, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly SCS-8; Smoke Control Station SCS-8L; Smoke Control Lamp Driver Station SCE-8; Smoke Control Expander SCE-8L; Smoke Control Expander Lamp STS-1; Security Tamper Switch *Rev. 05-08-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0224 Page 4 of 4 TM-4; Transmitter Module TR-A4/-B3N/-B4/-C4/-D3N/-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-256/BB--UZC; Universal Zone Coder/Backbox VCE-4; Voice Control Expander VCM-4RK; Voice Control Module VS4095/5; Keltron Remote Printer XPS-C/-M; Transponder XPC-8; Transponder Control Module XPIQ; Transponder Quad Intelligent Audio Module XPM-81-8L; Transponder Monitor Modules XPP-1; Transponder Processor XPR-8; Transponder Relay Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units suitable for high rise applications for use with separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period, shall not exceed 30 seconds. 2. Combined with Listing No. 7170-0028:223 *Rev. 05-08-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6940:131 • D-115 LCD-1 60 Liquid Crystal Display General The LCD-160 is a 640-character Liquid Crystal Display (LCD) annunciator and remote control for the NOTIFIER NFS-3030/ NFS2-3030 Fire Alarm Control Panel (FACP). The LCD-160 will mimic the top portion (160 characters) of the NFS-3030/ NFS2-3030's 640-character display. This provides the event and preprogrammed custom messages as displayed on the main panel. The full screen contains soft key functions, and can display other panel information. LCD-160 Features 640-character Liquid Crystal Display with backlit control. On-board input, output, and status indicators to support diagnostics. Software upgrades and foreign-languages character sets via serial port from a panel or other device using the Remote Data Port (RDP) interface, Upgrades do not require the replacement of any programmable devices. Rubberized keypad. Input for AKS-1 B key switch. Fits in two ACS annunciator module locations. Display and Control Center (DCC) participation/indication. RDP Interface Any communication between the control panel and any RDP device, such as the LCD-160, occurs over an RDP interface. RDP interface communication is supervised by the FACP and the LCD-160. RDP bus can drive up to 32 RDP devices. The FACP must be at one end of the bus; the last RDP device on the circuit must have an enabled end-of-line resistor. Each LCD-160 on the bus requires a non-resettable 24 VDC power connection. The power circuit is inherently supervised and a loss of power registers as a communica- tion failure at the control panel. The LCD-160 can be powered by a regulated remote power supply listed for fire-protective signaling use. If the 24 VDC power comes from a non-power-limited source, it must remain separate from the power-limited RDP bus. Specifications Input supply voltage (TB2): Regulated, filtered 24 VDC via non-resettable power supply interface listed for fire-protective signaling use. Sources can be: panels with integrated power supplies, main power supplies (AMPS-24, etc.), auxiliary power supplies (APS2-6R, etc.); or a compatible accessories output. If RDP devices are to be powered by separate power supplies, a common reference connection must be estab- lished. Data communications port (TB1): Power-limited RDP inter- face. NOTIFIER® by Honeywell Current draw: Standby current: 0.300 A with backlight on, 0.075 A with backlight off. Alarm current: 0.325 A with back- light on, all LEDs active. RDP BUS WIRING SPECIFICATIONS Wiring distance: 4000 feet (1219.2 m) at 18 AWG (0.78 mm2) between the panel and the last device on the RDP bus (sub- ject to system's power restrictions). Wiring size: 18 to 12 AWG (0.78 to 3.1 mm2) twisted-pair cable, with characteristic impedance of 120 ohms ± 20%. Wire resistance: Limit total wire resistance to 100 ohms on the RDP bus, and 10 ohms on the RDP device power circuit. Unloaded resistance between RDP connectors must be greater than 1K ohm. A remote power supply is required if total power wiring resistance exceeds 10 ohms. NOTE: 1) DO NOT RUN CABLE adjacent to, or in the same con- duit as: 120 VAC service; "noisy" electrical circuits that are power- ing mechanical bells or horns; audio circuits above 25 Vrms; motor control circuits; SCR power circuits; or non-power-limited circuits. 2) Refer to LCD-160 Manual, document no. 51850, if RDP devices are to be mounted in SEPARATE CABINETS or powered by REMOTE POWER SUPPLIES. PHYSICAL SPECIFICATIONS Temperature/humidity range: This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C/60 - 80°F. Shipping weight: 2.50 lb. (1.134 kg) DN-6940:B1 .8/31/2011 —Page 1 014 LCD-160 Interface and Indicators The liquid crystal display is 40 characters wide and 16 lines deep, and displays all programming screens and other infor- mation. The keypad is functional only when an entry is requested by the system. Enter or change fields and issue commands on the display by using the two types of keys on the keypad: fixed function and soft keys. Fixed function keys are the ten keys labeled on the front of the LCD-160, operating at all times on all screens unless oth- erwise noted. With both an active command center and DCC enabled at the panel, Acknowledge, Signal Silence, System Reset, and Drill require permission before they can be pro- cessed. Acknowledge: Press to respond to any event or trouble sig- nal. If enabled, silences the LCD-160 piezo sounder. Sends an acknowledge message to the panel. Signal Silence: Press to send a system silence command to the panel, with the particular silencing action information stored at the FACP. Verification screen appears on networked displays. System Reset: Press to send a system reset command to the panel, with the particular reset action information stored at the FACP. Verification screen appears on networked displays. Drill: Press (hold for two seconds) to activate all silenceable fire output circuits. Lamp Test: Press to test the LED indicators and the piezo, or display firmware version numbers. Fire Alarm: Scroll/display a list of associated events. Security: Scroll/display a list of associated events. Supervisory: Scroll/display a list of associated events. Trouble: Scroll/display a list of associated events. Other Event: Scroll between prealarm and disabled events. For complete information on key functions and effects on dif- ferent panels, refer to the LCD-160 Manual and panel manu- als. Soft keys are the six keys to the right and left of the display. Use them to select commands that appear on the display for each different screen. Refer to the screens in the LCD-160 Manual for descriptions of the applicable soft keys. STATUS LED INDICATORS Power (green) illuminates when AC power is within normal operating limits. Fire Alarm (red) illuminates when at least one fire alarm event exists. It will flash if any of these events are unacknowledged. Pre-Alarm (red) illuminates when at least one pre-alarm event exists. It will flash if any of these events are unacknowledged. Security (blue) illuminates when at least one security event exists. It will flash if any of these events are unacknowledged. Supervisory (yellow) illuminates when at least one supervi- sory event exists. It will flash if any of these events are unac- knowledged. System Trouble (yellow) illuminates when at least one trou- ble event exists. It will flash if any of these events are unac- knowledged. Other Event (yellow) (future release). NUP J3 Ji L BACKLIGHT CD 92 LCD-160 KEY SWITCH J2 1 2 00 LCD 19 ° 20 °POWER El F-1 IT VDI STATUS TB2 ('liuulllllllliliillill IIIIiIi') IN CO COMMON L MMON OUT RDP TBI RDP+ MICRO FAIL (.IIIIIIIIIIIIIIIIIII1IIIIII!k.) RDP+ LED14 OOUODDDDaUDDDDaU— RDP- -1 RECEIVE RDP— SW17 1_6I2 REF TRANSMIT REF EARTH LED13 Page 2 of 4— DN-6940:131 • 8/31/2011 ACKNOWLEDGED TROUBLE ELEVATOR LOBBY EAST WING FIFTH FLOOR 7239 SMOKE (PHOTO) 11:58:45A WED JUN 26, 2003 L03D002 EVENT COUNTS FIRE ALARMS:000 PREALARM:000 TROUBLE:001 SUPERVISORY:000 SECURITY:000 DISABLE:000 11:58:46A WED JUN 26, 2011 SIGNAL SILENCE MORE INFORMATION SYSTEM RESET PROGRAM MENU Signals Silenced (yellow) illuminates if notification appli- ances have been silenced. It flashes if some, but not all, of the NACs have been silenced. Point Disabled (yellow) illuminates when at least one device has been disabled. It will flash until all disabled points have been acknowledged. Controls Active (green) illuminates when the LCD-160 assumes control of the node as a primary display. DIAGNOSTIC LED INDICATORS Status, LED11 (green), blinks when the LCD-160 is on. Visi- ble to the installer/troubleshooter only. Receive, LED12 (green), blinks when data is received from the panel. Visible to the installer/troubleshooter only. Transmit, LED13 (green), blinks when data is transmitted to the panel. Visible to the installer/troubleshooter only. Microfail, LED14 (yellow), illuminates if the microcontroller fails. Visible to the installer/troubleshooter only. Event Handling and the Display and Control Center UL and ULC require that when multiple command and control centers are installed, only one operator at any location can be in control at any given time for functions such as acknowledge, silence, and reset. This is called the Display and Control Cen- ter (DCC). DCC operation provides a mechanism to pass net- RDP Bus Wire Runs FACP LCD-160 Power 12 to 18 AWG 1121 (3.1 to 0.78 mm') LCD-160 non-resettable '. Two-wire RDP Bus 4000 feet (1219.2 m) max. I power-limited and supervised Sample Screen: Point Event Display work control to alternate network control centers. This protocol allows for a request for control" from another networked panel, which will be accepted or rejected from the current DCC. A 15-second time-out allowance provides for an auto- matic passing of control in the event there is no response from the original DCC. If the NFS-3030/NFS2-3030 panel associ- ated with an LCD-160 has been programmed to participate in DCC, all remote displays with Local Control ON will automati- cally participate. Agency Listings and Approvals These listings and approvals apply to the LCD-160. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL: S635 ULC: S635 MEA: 8-04-F (annunciator only) FDNY: COA#6065 (with NFS2-3030) CSFM: 7120-0028:0227, 7165-0028:0224 FM Approved DN-6940:B1 • 8/31/2011 - Page 3 of 4 Product Line Information tL.1®: 640-character Liquid Crystal Display annunciator. Backboxes The following backboxes can be surface- or semi-flush- mounted to provide an enclosure for remote mounting. Use with 1/2" (1.27 cm) conduit in the provided knockouts. ABS-21D (black) and ABS-2DR (red): Surface- or semi-flush enclosure for remote mounting. Mounts an LCD-160 directly to the enclosure's hinged dress plate. The ABS-2D and ABS- 2DR do NOT support the installation of the AKS-1 B key- switch. Not for use in Canadian applications. Optional trim ring TR-ABS2D for semi-flush mounting. Dimensions, box: 12.0" (30.480 cm) H x 12.0" (30.480 cm) W x 3.797" (9.644 cm) D (NOTE: The black ABS-2D is slightly deeper). Dimensions, door: 12.0 (30.480 cm) H x 12.0" (30.480 cm) W x 1.250" (3.175 cm) D. ABS-41D (black) and ABS-4DR (red): Surface- or semi-flush- enclosure for remote mounting. Mounts an LCD-160 and two annunciators directly to the enclosure's hinged dress plate. The ABS-4D and ABS-4DR do NOT support the installation of the AKS-1 B key-switch. Dimensions, box: 11.97" (30.40 cm) H x 19.87" (50.47 cm) W x 3.5" (8.89 cm) D. Dimensions, door: 11.97" (30.40 cm) H x 19.87" (50.47 cm) W x 1.250" (3.175 cm) D. ABF-213: Black flush enclosure for remote mounting. Mounts an LCD-160 directly to the enclosure's dress plate. Not for use in Canadian applications. Includes a painted black metal trim plate (11" (27.94 cm) high x 10.625" (26.99 cm) wide] and adhesive-backed annunciator label. 9.938" (25.24 cm) high x 9.188" (23.34 cm) wide x 3.75" (9.525 cm) deep. ABF-2DB: Black flush enclosure for remote mounting. Mounts an LCD-160 directly to the enclosure's dress plate. Does not support the installation of AKS-113. Box dimensions: 9.938 (25.24 cm) high x 9.188" (23.24 cm) wide x 3.75" (9.525 cm) deep.Door dimensions: 11" (29.94 cm) high x 10.375" (26.35 cm) wide x 0.75" (1.9 cm) deep. ABF-413: Black flush enclosure for remote mounting of one LCD-160 and two annunciator modules directly to the enclo- sure's dress plate. Knockouts are provided for use with 1/2" (1.27 cm) conduit. Includes a painted black metal trim plate [11" (27.94 cm) high x 19.375" (49.21 cm) wide] and an annun- ciator label. 9.938" (25.24 cm) high x 17.75" (45.09 cm) wide x 2.5" (6.35 cm) deep. CAB-4 Series cabinets: Surface- or semi-flush-mounted, in sizes to accommodate one to four rows of equipment plus bat- teries (up to two 26 AH batteries). Four sizes are available. Doors are ordered separately, and feature reversible hinges to mount doors on the left or right side. Doors also open a full 180°. Keylocks are included. For dimensions and further infor- mation, see datasheet DN-6857. ACCESSORIES DP-DISP: Dress Panel Display for cabinet mounting of an LCD-160. LCD-160 mounts directly to the dress panel, which hinge-mounts to the top tier of a CAB-4 Series backbox. ADP-4B: Annunciator Dress Panel-413 (black) for cabinet mounting of an LCD-160. LCD-160 mounts directly to the dress panel, which hinge-mounts to the tier of a CAB-4 Series backbox. TR-ABS2D: Optional trim ring for semi-flush mounting ABS- 2D(R). V13-2113: Vented Dress Panel for use with the ADP-46 dress panel installed in the top tier of a NOTIFIER cabinet, It covers the gap between the dress panel and top of the cabinet. AKS-1 B: Annunciator Key Switch provides access security for the control switches on the LCD-160. Key-switch kit includes key, hardware, and an annunciator label. NOTIFIER® is registered trademark of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. : We cannot cover all specific applications or anticipate all requirements. EIIIIIIIIIIENINS & WMFAMMNG All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 4 of 4- DN-6940:B1 • 8/31/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:0227 Page 1 of I CATEGORY: 7120--ANNUNCIATORS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Model *LCD160 annunciator control system. Unit has the ability to display custom messages, graphics and mirror the compatible FACP display annunciation. Refer to listee's data sheet for additional detailed product description and operational considerations. Unit consists of the following modules: ABF-213, -413 Enclosures ABS-2D/-2DR/-4D/-4DREnclosures CAB 4 Series Enclosures ADP-4B Annunciator Dress Panel DP-DISP Dress Panel VP-2/-2B Vented Dress Panel AKS-1, -113 Annunciator Key Switches RATING: 17.6-30Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an annunciator for use with separately listed compatible Model NFS-3030 fire alarm control unit (CSFM Listing No. 7165-0028:224 & 7170-0028:223). Refer to listee's Installation Instruction Manual for details. *Rece 04-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FCPS.24S6(C/E) & FCPS. 24S8(CIE) 6- & 8-Amp 24-Volt Remote Power Suoolies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 0124 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS-24S61-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-2458 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C & FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features UL-Listed NAG synchronization using System Sensor, Wheelock, or Gentex "Commander2" appliances. Operates as a "sync-follower" or as a "sync-generator (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAG (NAG expander mode) or jumped perma- nently ON" (stand-alone mode). Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NAGs. 6-amp (FCPS-2456) or 8-amp (FCPS-2458) full load out- put, with 3 amps maximum/circuit, in NAG expander mode (UL 864). 4-amp (FCPS-2456) or 6-amp (FCPS-2458) continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NAGs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated NAG power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75"D (cm: 38.1H x 36.83W x 6.985D). DN-6927:A2 NOTIFIER® by Honeywell Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FGPS-24S6G/-2458G: 120 VAC, 60 Hz, 3.2A maximum. FCPS-24S6E/-2458E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-24S6: 4.0 A maximum. - FCPS-24S8: 6.0 A maximum. Total short-term current for all outputs (NAG expander mode): - FCPS-24S6: 6.0 A maximum. - FGPS-24S8: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. DN-6927:A2 • 5/17/13 - Page I of 2 Float-charge voltage: 27.6 VDC. Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-2456) or 8.0 A (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-2456) or up to 6.0 A (FCPS-2458). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE.- Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-2456/-2458 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-2456/-2458 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-2458 are configured (via DIP switch settings) as a sync generator," the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator' mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-2456 and FCPS-2458 comply with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (FCPS-2456C & FCPS-2458C) CSFM Approved: 7315-0028:225 MEA: 299-02-E FM Approved Ordering Information FCPS24966.0 A, 120 VAC remote charger power supply Includes main printed circuit board, transformers, enclosure t(15"H x14.5"W x 2.75"D([cm: 38.1Hx 36.83Wx6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULC-Iisted. FCPS-24S6R: Same as FCPS-24S6 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-2458 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. @2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. I .1 We try to keep our product information up-to-date and accurate. 1133~ We cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6927:A2 • 5/17/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING No. 7315-0028:0225 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models FCPS-2456 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 1-24-O3KK ØTI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division NBG.1 2LX Addressable Manual Pull Station General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on CLIP protocol loops. Up to 159 NBG-12LX stations per loop on FlashScan® pro- tocol loops. Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLCloopyoItage: .28.0.VDC. Maximum SLc_standby current: 375 pAl MaximumSLC alarm current: 5 mA.) Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location DN-6726:D • H-240 NOTIFIER® by Honeywell The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4 (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4 (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 on FlashScan® systems, 1 - 99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-b 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or DN-6726:D • 4/13/2012 - Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information (i1B6-12LX: Dual-action addressae pufl station. 1ncFudskèj. clocking feature. (Listed for Canadian and non-Canadian appIi- (cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. CSFM: 7150-0028:0199. FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). BSMI: C1313066760047. U.S. Coast Guard. Lloyd's Register. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International nc. All rights reserved. Unauthorized use of this document is strictly prohibited. _fl This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MIIFlNI a UMUICTIRINO All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-6726:1) • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-I2LR, NBG-I2LRA, NBG-I2LAO, NBG-12LAOB, NBG-12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-I2NC, NBG-I2WP, NBG-I2LWP, NBG-12L, NBG-I2LX, NBG-I2LA, NBG-12P5, NBG-I2LSP, NBG-12LPS, NBG-12LPSP, NBG-I2SP, NOT-BGI2LX, NBG-12LXSP, NBG-I2LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-I2WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-I2LAO, NBG-12L0, NBG-I2LAOB and NBG-12L0B are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6935:E • H-202 FSP.851 (A) Series Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan® General Notifier FSP-851 (A) Series intelligent plug-in smoke detec- tors with integral communication provide features that sur- pass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is con- tinuously monitored and reported to the panel. Point ID capa- bility allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelec- tric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed- temperature thermal sensing on the FSP-851T(A). The FSP- 851R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851 (A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 3600 viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashS- can systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appear- ance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. NOTIFIER® by Honeywell FSP-851(A) in B2IOLP(A) Base Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1° (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1(15.5cm) diameter. - B501 (A): 4.1° (10.4 cm) diameter. - B200S(A): 6.875" (17.46 cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. - B224B1(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851 (A), 0°C to 49°C (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F). Low temperature signal for FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.54°C). FSP-851R(A) installed in a DNR(A)/ DNRW, -20°C to 70°C (-4°F to 158°F). ULJULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/ mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, docu- ment A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby CuiTént (max. avg.): 300pA @ 24VDC (one com- munication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 2VDC ("ON"). DN-6935:E°2/11/2015—Page 1012 Installation FSP-851 (A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors with- out using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5 (3.81 cm) deep. For a chart of compatible junc- tion boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applica- tions may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S1 115. ULC Listed: SillS (FSP-851A, FSP-851RA, FSP- 851TA). MEA Listed: 225-02-E. FM Approved. CSFM: 7272-0028:0206. Maryland State Fire Marshal: Permit #2122. BSMI: C1313066760036. CCCF: Certif. #2004081801000017 (FSP-851T) Certif. #2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/ 0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A'suffix indicates ULC Listed model. Low-profile intelligent photoelectric sensor. Must (be mounted to one of the bases listed below. FSP-851A: Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRNDNRW. FSP-851RA: Same as FSP-851R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501 (A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw ter- minals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224Bl(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases. ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851(A) only; box of 10. WCK-200B: White detector covers for use with FSP-851 (A) only; box of 10. NOTIFIER® is a registered trademark of Honeywell International Inc. 02015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 111111111111IMMMNS All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6935:E • 2/11/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0206 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-851, FSP-851, FSP851R* and FSP-851T photoelectric type smoke detectors. Models FSP-751T and FSP-851 T employ a 135°F supplement integral heat sensor which only assists in afire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-751T, FAPT-751, FAPT-851, FSP-851, FSP-851 R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity between 04000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FST-851 (A) Series Intelligent Thermal (Heat) Detectors with FlashScan® General Notifier FST851(A) Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's address to be set with rotary, decimal address switches, pro- viding exact detector locations. FST-851 (A) Series thermal detectors use an innovative thermistor sensing circuit to pro- duce 135°F/57°C fixed-temperature (FST-851/A) and rate-of- rise thermal detection (FST-851 fl/A) in a low-profile package. FST-851 H(A) provides fixed high-temperature detection at 190°F/880C. These thermal detectors provide effective, intelli- gent property protection in a variety of applications. FST- 851(A) Series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-851R/A), 15°F (8.3°C) per minute. Factory preset fixed temperature at 135°F (570C); high-tem- perature model fixed at 190°F (88°C). Addressable by device. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Two-wire SLC connection. Visible LEDs "blink" every time the unit is addressed. 3600-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identifica- tion. Remote test feature from the panel. Built-in functional test switch activated by external magnet. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Backward-compatible. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. Sealed against back pressure. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. SEMS screws for wiring of the separate base. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. DN-6936:B • H-211 NOTIFIER® by Honeywell FST-851(A) in B2IOLP(A) Base 94-5V plastic flammability rating. Remote LED output connection to optional RA100Z(A) remote LED annunciator. Optional sounder, relay, and isolator bases. Optional flanced surface mounting kit. Specifications Size: 2.1" (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. - B501 (A): 4.1° (10.4 cm) diameter. - B200S(A): 6.875" (17.46 cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. - B224B1(A): 6.2" (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Operating temperature range: FST-851 (A) Series, FST- 851 R(A): —20°C to 38°C (-4°F to 100°F); FST-851 H(A): —20°C to 66°C (-4°F to 150°F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% - 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (570C), rate-of-rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (88°C). ELECTRICAL SPECIFICATIONS Voltage range: 15- 32 volts DC peak. Standby current (max avg )300 pA © 24 VDC (one com minication every 5 seconds with LED enabled). LED current (rnaL):65 mA! 24 VDC (ON"). Applications Use thermal detectors for protection of property. For further information, go to systemsensor.com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- vides detailed information on detector spacing, placement, zoning, wiring, and special applications. DN.6936:13" 12/07/2011 —Page 1 of 2 Installation The FST Series plug-in intelligent thermal detectors use a sep- arate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. A spe- cial tool allows maintenance personnel to plug in and remove detectors without using a ladder Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class SB') wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document.ln some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: 5747. ULC Listed: S6978. MEA Listed: 383-02-E. FM Approved. CSFM: 7270-0028:0196. BSMI: C1313066760025. CCCF: Certif. #2004081801000018. U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640!NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: 'A" suffix indicates ULC Listed model. FST851: Intelligent thermal detector. Must be mounted to one' of the bases listed below. FST-851A: Same as FST-851 but with ULC Listing. FST-851 R: Intelligent thermal detector with rate-of-rise fea- ture. FST-851 RA: Same as FST-851 R but with ULC Listing. FST-851H: Intelligent high-temperature thermal detector. FST-851 HA: Same as FST-851 H but with ULC Listing. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501 (A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Addressable Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Intelligent relay base. Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive: 0.3 A © 110 VDC inductive; 1.0 A @ 30 VDC induc- tive. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. Maximum: 25 devices between isolator bases; see Note 2 under Installation. ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low-profile. F1 10131113: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. Supported by B21OLP(A) and B501 (A) bases only. SMB600: Surface mounting kit, flanged. M02-04-00: Test magnet. M02-0900: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. Includes T55-127-010. T55-127-01 0: Detector removal tool without pole. XP-4: Extension pole for XR213. Comes in three 5-foot (1.524 m) sections. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. 13=1=1 We cannot cover all specific applications or anticipate all requirements. MSINERINS I 1111111111111FAMMKII All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more informatioi, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6936:13 • 12/07/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0196 Page 1 of 1 CATEGORY: 7270-- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FST-751, -851, -851 R, -851 H (fixed temperature) and FST-751 R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models FST-751, -751R, -851, and -851R = 135°F fixed temperature Model FST-851H = 190°F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Models B501, *1321OLP (CSFM Listing No. 7300-1653:0109), or B71OLP base (CSFM Listing No. 7300-0028:173) and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. RF&*Z01111i MR This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60689:B FCO.851 (A) InteIIiQuadTM PLUS Advanced Multi-Criteria Fire/CO Detector NOTIFIER® by Honeywell General World-class fire and carbon monoxide (CO) detection com- bined in a single addressable device provides a practical solu- tion for today's market. The IntelliQuad PLUS FCO-851(A) Advanced Multi-Criteria Fire/CO Detector is a plug-in, addressable device that pro- vides both fire and carbon monoxide (CO) detection. For fire, the detector combines four separate sensing elements in one unit (smoke, CO, light/flame, and heat) to sense multiple com- ponents of a fire. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulate. For CO, the detector's electrochemical sensing cell creates a separate signal for life safety CO detection. CO is a colorless, odorless, and deadly gas that is virtually impossible to detect with the human senses. It is released whenever carbon-based fuels (from fossil fuels to firewood) burn without enough oxygen to form CO2. Because the poten- tial exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada. The FCO-851 (A) is listed to the UL 268 standard for smoke detectors and the UL 2075 standard for system-con- nected life safety carbon monoxide monitoring. The FCO-851(A) should be used in conjunction with the B200S(COA) intelligent sounder base, which can generate either a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication. The B200S(COA) recognizes the System Sensor synchroniza- tion protocol. This enables it to be used as a component of the general evacuation signal - along with other System Sensor horns, horn strobes, and chimes - when connected to a power supply or Fire Alarm Control Panel (FACP) output capa- ble of generating the System Sensor synchronization pulses. With each sounder base carrying a unique address, the FACP can then command an individual sounder - or a group of sounders - to activate. The command set from the panel can be tailored to the specific event, allowing selection of volume, tone, and group. NOTE: The FCO-851(A) is compatible with the NFS-320(C), NFS- 320SYS, NFS2-640, and NFS2-3030 operating with firmware ver- sion 17.0 (or higher) in FlashScan® mode; CLIP mode not sup- ported. Features Unique ability to detect all four major elements of a fire. Separate CO detection signal. Highest nuisance alarm immunity. Automatic drift compensation of smoke sensor and CO cell. Uses only one address on the SLC. RealTest® CO testing capability. Separates audible signal for fire or CO alarm when used with the B2005 base (13200SCOA in Canada). CO cell end-of-life warning and fault. FlashScan operation. - FCO-851(A) in B200S(COA) Sounder Base Sensitivity Settings and Suggested Applications Level 1: 1% / ft of smoke. Suggested for very clean envi- ronments such as laboratories. Level 2: 2% / ft of smoke. Suggested for clean environ- ments such as offices. Level 3: 3% / ft of smoke. Suggested for moderately clean environments such as hotel rooms, dorm rooms. Level 4: 3% I ft of smoke with different algorithm process- ing and weighting of sensor elements. Suggested for hotel rooms near a shower, boiler rooms. Level 5: 4% / ft of smoke. Suggested for equipment rooms, kitchens, paint shops. Level 6: Thermal alarm at 135°F (570C). Once the CO cell has reached end-of-life, the CO sensor no longer provides life safety protection; however, when the fire detector enters Photo, Thermal, Infrared (PTIR) mode, the fol- lowing sensitivities apply: Level 1: 1% I ft of smoke. Suggested for very clean envi- ronments such as laboratories. Level 2: 2% / ft of smoke. Suggested for clean environ- ments such as offices. Level 3: 3% I ft of smoke. Suggested for moderately clean environments such as hotel rooms, dorm rooms. Level 6: Thermal alarm at 135°F (57°C). Specifications PHYSICAL SPECIFICATIONS Size: 3.46" (8.79 cm) high x 6.875 (17.46 cm) diameter installed in B200S(COA) base. Shipping weight: 4.6 oz. (130.41 g). Color: Ivory. DN-60689:B • 12/3/2012 - Page 1 of 2 Operating humidity range: 15% - 90% relative humidity (noncondensing). Operating temperature: 0°C to 38°C (32°F to 1000F). Air velocity: 0-4000 ft/mm. (0 to 20 rn/sec.). ELECTRICAL SPECIFICATIONS Operating Voltage range: 15-32 volts VDC. Standby current (thak avg) 300 hA at 24 VDC (one com- munication every 5 seconds with LED blink enabled). Maximum Alarm Current (LED on): 7.2 mA at 24 VDC. CO ALARM ACTIVATION LEVELS Alarm activation levels as defined by UL Standard 2034: Concentration of CO Maximum Alarm Time Response 70 (+1- 5) PPM 240 mm (not less than 60 mm) 150 (+1- 5) PPM 50 mm (not less than 10 mm) 400 (+1- 10) PPM 15 mm (not less than 4 mm) Ordering Information NOTE: "A suffix indicates ULC listed model. -851: IntelliQuad PLUS Advanced Multi-Criteria Fire Detector.' FCO-851A: IntelliQuad PLUS Advanced Multi-Criteria Fire/CO Detector, ULC listed. B200S: Intelligent programmable sounder base. B200SCOA: Intelligent programmable sounder base, ULC listed. Includes CO detector markings in English and French. M02-04-00: Detector Test Magnet. M02-09-00: Telescoping Test Magnet. Agency Listings and Approvals The listings and approvals below apply to the primary product. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S1115 (FCO-851). ULC: S1115(FCO-851A). CSFM: 7275-0028:0264. InteIIiQuadTM is a trademark and NOTIFIER®, Rearrest® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. z3a1=1=1 We cannot cover all specific applications or anticipate all requirements. ENNINMINS & IIIIIIIIII[IM1311111ING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60689:13 • 12/3/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7275-0028:0264 Page 1 of 1 CATEGORY: 7275 -- COMBINATION SMOKE/CO DETECTOR-PHOTOELECTRIC TYPE LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Model FCO-851 combination multi-criteria photoelectric smoke and Carbon Monoxide detector with supplemental heat sensor. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, NFPA 720, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as smoke detectors for use with Model B200S base and listee's separately listed compatible fire alarm control units. Also suited for gas and vapor detection. The supplemental heat sensor is intended for use to reduce the nuisance alarm and is not intended for use as a stand alone heat detector. 07-13-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6720:E FMM.1 (A), FMM-1 01(A), FZM.1 (A) & FDM.1 (A) Monitor Modules with FlashScan® General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM1(A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3' (3.302 cm) H x 2.75' (6.965 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM.1 (A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterilow devices, or other normally- NOTIFIER® by Honeywell FMM.1(A) (Type H) open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current:. 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:E • 07/30/2015 - Page 1 of 4 FMM.1 01(A) Mini Monitor Module Temperature range: 32°F to 120°F (0°C to 49°C). Built-in type identification automatically identifies this Humidity range: 10% to 93% noncondensing. r1a,iro ac mnni+rnr —A. I. +rn tha nanal il_C l_i? C till_I IIl%JI II il_l_iiC lid II IC 1JOI CI. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 - 99 on CLIP loops. 1415 0 1 ADDRESS o 1 2 2 H 1O5 11 4 LOOP 8 76 8 76 TENS ONES Ii I • oil I oil jIl II I.j Li -iH 10 The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Aväg6perating current: 350 pA, 1 communication ve 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Dimensions: 1.3" (3.302 cm) high x 2.7511 (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 611 (15.24cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on FlashScan loops, 01 —99 on CLIP loops. LED flashes during normal operation; this is a program- mable option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Page 2 of 4— DN-6720:E • 07/30/2015 Humidity range: 10% to 93% noncondensing. Agency Listings and Approvals Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x In some cases, certain modules may not be listed by certain 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x approval agencies, or listing may be in process. Consult fac- 2.125" (5.398 cm) deep box. tory for latest listing status. FDM.1 (A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPEcIFIcATIoNs Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1 (A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, 0r8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. J& CAUTION: Avoid duplicating addresses on the system. UL: S635. ULC:S635. FM Approved. CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. MEA: 457-99-E. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). Fire Dept of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. IFMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4(10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. DN-6720:E • 07/30/2015 - Page 3 of 4 FlashScan® and NOTIFIER® are registered trademarks and FireWatch is a trademark of Honeywell International Inc. 02015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so ooi This document is not intended to be used for installation purposas. We try to keep our product information up-to-date and accurate. . . We cannot cover all specific applications or anticipate all requirements. lIlN & IIIIIJI11111111191111131111118 QUALITY SYSTEMS All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161 FAX: (2O) 484-7118. www.notifier.com Page 4 of 4— DN-6720:E • 07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywelI.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XPIO-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FCM-1 (A) & FRM-1 (A) Series Control and Relay Modules General FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1(A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1 (A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 - 99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1(A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashSca,xt releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01 -159). DN-6724:B3 NOTIFIER® by Honeywell T)t E) PWR I.) .. hUt T)OEt)PWR() F) TI raw I-) c1 z cc FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1 (A) provides two Form-C dry contacts that switch together. Operation Each FCM-1(A) or FRM-1(A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM.1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3 • 2117/2011 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and T1 1): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 40 (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM.1(A) Normal operating voltage: 15 to 32 VDC. Max mi current draw:,- 6.5 mA (LED on). Average operating current:-230 pA direct poll;255 pA group polL - EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4 (101.6 mm) wide x 1.25 (31.75 mm) deep. Mounts to a 40 (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM-1 (A) Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5A 30 VDC Inductive Coded (L/R=5ms) 1A 30 VDC Inductive Coded (L/R=2ms) .3A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. j'lntelhgent Addressable Relay Module A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 0111INSINS & 1111111111111FACTMI119 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2- DN-6724:133 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XPIO-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt er This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ov operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Innov ex air The InnovairFIex Series DNR and DNRW are intelligent (addressable) non-relay photoelectric duct smoke detectors. Like all InnovairFIex detectors, the DNR and DNRW both feature an adjustable housing design that fits square and rectangular installation footprints, mounts to both round and rectangular ductwork, and utilizes tool-free, plug-in sampling tubes for increased application flexibility and installation ease. These units sense smoke in challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). For even more extreme environments like rooftops, the DNRW's NEMA 4-rated watertight and UV-resistant housing protects against windblown dirt and dust, rain, and hose directed water, enabling it to be installed without a costly enclosure, saving time and money. The InnovairFIex housing cover isolates the sensor head from the low-flow feature for simple maintenance, and a cover tamper feature initiates a trouble signal for a removed or improperly installed sensor cover.The housing also provides a 1/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module to meet specific application requirements. These detectors can be customized to meet local codes and specifications without additional wiring. SYSTEM SENSOR® Intelligent Non-Relay Photoelectric Duct Smoke Detector The lnnovairFlex'° Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features Photoelectric, integrated low-flow technology (detector head sold separately) Air velocity rating from 100 ft/min to 4,000 ft/mm Adjusts to square and rectangular mounting configurations Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented tool-free, plug-in sampling tubes New cover tamper signal Increased wiring space with a new 1/4-inch conduit knockout Housing has space for mounting a relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection UL 268A listed Remote testing capability Requires com line power only NEMA Type 4 UL listed for non-hazardous indoor and outdoor applications (DNRW only) • UV-resistant, UL-listed housing and cover material (DNRW only) The InnovairFIex line is compatible with all previous Innovair models, including remote test accessories, for easy retrofits. WARNING: Duct smoke detectors have specific limitations. Agency Listings & <~> 0 MSFM LISTED APPROVED approved 2911 3029700 3242-1650209/210 2125 InnovairFIex Duct Smoke Detector The air duct smoke detector shall be a System Sensor lnnovairFlex" DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA 4 Duct Smoke Detector.The detector housing shall be UL listed per UL 268A specificallyfor use in air handling systems.The flexible housing of the duct smoke detector fits both square and rectangular footprints.The detector shall operate at air velocities of 100 IL/min to 4,000 ft/min (0.5 rn/sec to 20.32 m/sec).The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS1 51 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Size: (Rectangular) (Square) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA 4 (DNRW only) Operating Temperature Range: -4°F to 158°F (-20°C to 70°C) Storage Temperature Range: -22°F to 158°F (-30°C to 70° C) Operating Humidity Range: 0% to 95% relative humidity (non-condensing) Air Duct Velocity: 100 to 4,000 ft/mm (0.5 to 20.32 m/s) DCOIL (if included): 17.5 -26.4 VDC, 95 mA max Electrical Ratings lease see deiecior head installation manual for electrical specification? Accessory Current Loads at 24 VDC Device - Standby Alarm RA100Z 0 m 12mAMax. RTS1S1/RTS151KEY 0 m 12mAMax. Installing the InnovairFIex Sampling Tube The InnovairFiex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). A05-0422-OO5 DNRto RTS1S1/RTS1S1 KEY with "R" Remote Test Capable Detector Head Option: l.1fIN1 l*I(IIS]lI qzv"M: comm p I RTS 151/RTS 151 KEY Wiring for Intelligent Non-Relay Duct Smoke Detector System wiring diagram for DNR: ZI I _ COMM. ----I I LINE(-i-) I COMM. I I LINE I I I COMM. LINE(-) I UL/FM LISTED 1ST 2ND CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP DNR to RA1 OOZ: "s (+) ..L RA100Z (-) I REMOTE ALARM LED OPTION 1 PER UNIT DNR to RTS1 51/RTS151 KEY with DCOIL Option*: TEST COIL + EXTERNAL TEST COIL— __ SUPPLY_r{POWER COMM+ OUT (CONV ONLY) + COMM— RTS151/RTS151KEY REMOTE TEST STATION RA/RTS - RA+ LED OPTION 1 PER UNIT RTS + TEST COIL OPTION 1 PER UNIT 95 mA CURRENT DRAW *Important Notes The use of either the RTS1 51 or RTS1 51 KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the DNR or DNRW installation manual for more information. The RTS1 51/RTS151 KEY test coil circuit requires an external 24 VDC power supply which must be UL listed. A05-0422.005 Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. Lk RT5151 UL S2522 RTS1S1 KEY ULS2S22 RA100ZULS2522 Orderina Information iiT1lgent non-relay photoelectric low-flow duct smoke detector' DNRW Watertight intelligent non-relay photoelectric low-flow duct smoke detector Accessories DCOIL Remote test coil required with RTS451/RTS451 KEY/RTS 15 1 /RTS 151 KEY DST1 Metal sampling tube duct width up to 1 f (03m) DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DSTS Metal sampling tube duct widths 4 f to 8 f (12 to 2.4 m) DST1 0 Metal sampling tube duct widths 8 ft to 12 ft (24 to 3.7 m) P48-21-00 End cap for metal sampling tubes ETX Metal exhaust tube duct width lft (0.3 m) M02-04-00 Test magnet RA OOZ Remote annunciator alarm LED RTS151 Remote test station RTS1 51 KEY Remote test station with key lock DH4000E-1 Weatherproof enclosure 02010 System Sensor \ I 3825 Ohio Avenue. St. Charles, IL 60174 S'EI'J5'OR Phone: 800-SENSOR2. Fax: 630-377-6495 current product mfor—tim, including the latest —ion ofthis da~ sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1653:0209 Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyev@honeywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-23-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR® Indoor Selectable. Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNALING @ 0 LISTED A1111111111 $5512 FM approved except 7125-1653 0504 S4011 for ALERT models 7135-1653:0503 3057383 The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor [-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model listed to UL 1971 and U[ 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MD[3 listed to U[ 464 and shall be approved for fire protective service. The module shall synchronize [-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/ElectricalII.1tit[.]l Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) InputTerminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVOSS6SOO UL Current Draw Data Candela 8-17.5 Volts DC 116-33 Volts DC FWR 15 87 [41; 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe - DC Input 8-17.5 Volts lscd 30cd 16-33 Volts- ' 15cd 30cd 75cd 95cd - 115cd 150d 177cd Temporal High 103 167 ill I ' 90 143 165- 187 217 254... Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AV0S86800 L-Series Dimensions 2.47 1.37 2.50 [UM Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information -- Ceiling Horn Strobes Ceiling Strobes SCRL Strobe, Red PC2RL 2-Wire, Horn Strobe, Red SCWL 7 Strobe, White WiHorStrobe, White SCWL-CLR-ALERT Strobe White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White SYSTEM 3B25 Ohio Avenue • St. Charles, IL 60174 Pr da I spec ftcatorts Sob subject lc Sensor ct to change wittroa: notice. Va rrr t syslesetrsor.corn SENSOR Phone: 800-SENSOR2 • Fax- 630-377-6495 for current product irttortrsatios. inctadng the latest version at this data sheet. AVDS868S1 - 03117 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: System Sensor Indoor 2-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP and P2WL-SP Wall Horn Strobes; PC2RL and PC2WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZ\NC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WalITrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: 02-14-17 gt T This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ov operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20 KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division U R E SYSTEM SENSOR® Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices Compatible with MDL3 sync module Listed for wall mounting only Agency Listings SIGNALING &D A1111111111 x i"" S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383, 3057072 The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/e-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the SyncoCircUitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor [-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR12 Operating Voltage Range 8 to 17.5 V(12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal) or 16.5 to 33 V (24 V nominal) InputTerminal Wire Gauge 12 to 18AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 1.91 "D (143 mm Lx 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46" W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6"Lx 4.7"W x 1.25"D (143 mm x 119 mm x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" 0 (133mm Lx 88mm W x 32mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8-17.5 Volts 16-33 VOlts Candela DC IDC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 1 107 136 95 N/A '121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts t16-33 Volts DC Input 15cd 30cd 15cd• 30cd 75cd 95cd llOcd 135d 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.lKTemporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. 5 L-Series Dimensions 1.91 - 3.46 - 1.25 .I.,.s.s's.s. 5.27 MINN. L Compact Strobe / Horn Strobe L-Series Ordering Information Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red 2 Wire H6St[obe White] P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SAL Strobe, Red SWL. - - 'Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SAL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT —3.46 --i 1.25 000 0 6.000200 .27 0 :,000,0000000:0: L o 11 0000,0 S20 Compact Horn trN Horn Model Horns Description HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have 'ALERT" marking on cover f\ 5)r57E,I,y 3825 Ohio Avenue • St. Charles, IL 60174 02017 System Sensor. or Current product intOrmalion. including he latest version ci this data sheel. SENSOR" Phone :800 • Fax: 630-377-6495 Product specifications subject l0000ttgewithOUt notice. VOI syslernsetlSor.cOm www.systemsensor.com AvoS86503 • 03/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP and P2WL-SP Wall Horn Strobes; PC2RL and PC2WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WaliTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 3O,2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20 KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDCIFWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlertO Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from —40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGNAUNG /1 :Zfi PJIEA 73OO.i61 (outdoor strobes) LISTED approved 7125-1 653 188 (horn strobes, S4011 )chmes, hors strobes, horns) APPROVED chrrre strobes) S3593 outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653 189 (hurts. domes) !!ii8yniLSensor SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40°F to 151°F Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verity proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 3.4-inch top and bottom conduit entries and 3.4-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. A SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for tire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6'L x 4.7"W x 2.5D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6'L x 4.7"W x 1,3D (142 mm Lx 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7L x 5.1 x 2.0'D (145 mm L x 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVQSO12O1 UL Current Draw Data 8-17.5 Volts 116.33 Volts Candela DC FWR DC FWR Standard 15 123 128 66! 71 Candela 15/75 142 148 77 81 Range 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 DC Input 15 15175 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Sound Volts Volts 24-Volt-Nominal Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 Coded Medftirn 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDSOI2O1 Strobe IJ1rfJj Listed Candela Candela rating at —40°F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 1177 185 1185 F-] Wall-Mount Horn Strobes erproof Back Box SpectrAlert Advance Diagrams Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-1 20 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic. weatherproof back box) SVVK t Strobe Standard cd White Outdoor (includes plastic weatherproof back box) SWHK*f Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White. Metal Weatheroroof Back Box Notes: * Add "-P' to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and \NTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. "S TElVi 3825 Ohio Avenue • St. Charles, IL 60174 @2012 System Sensor. Pr du I specrircat ow subject to change without notice. Vs I systerns0050r.co'r ~31*SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 for currer'tp'oducirr'tormotron, "ciudrogihe latest veroo,rot this data sheet, AvDS01201 • 3/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0187 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models SWK, SWHK, SCWK, SCWHK, SRK, SRHK, SCRK and SCRHK strobe lights intended for indoor or outdoor use and may be mounted on the wall or the ceiling. These strobe lights are suitable for outdoor use at an operating temperature range of -40°F to 150°F (-40°C to 660C)* rating and are NEMA 4X rated when used with the Listed models SA-WBB (wall), SA-WBBW (Wall) or the model SA-WBBC (ceiling), SA-WBBCW (Ceiling) weatherproof back boxes. May be followed by suffix -P for plain housing with no lettering. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for general signaling. For indoor or outdoor use. Refer to listee's Installation Instruction Manual for details. NOTE: Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Corrected 07-22-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division f SYSTEM $ SENSOR® / 13200S!13200S-LF Intelligent Sounder Bases System Sensor B200S series sounder bases set a new standard for performance, installation ease, and aesthetics. .-. /1 IT;. • £ ( 2 B2005-LF B200S The B200S sounder base series is designed for new and existing dwelling unit applications. It offers maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. B200S Series Features Addressability for maximum configuration flexibility Two volume levels (75 or 85 dBA) Multiple event-driven tone outputs Supports Continuous, ANSI Temporal 3, ANSI Temporal 4, and March Time tones Custom tone capability with some FACP models Ability to synchronize with other System Sensor notification devices UL 268 and UL 464 compliant Pre-wire mounting plate fits various junction box sizes Mechanical locking feature prevents removal of attached sensor head Additional terminal connections on Canadian model (132005A) enable silence feature 520 Hz +1- 10% square wave tone (B200S-LF) The sounder base "listens in" to the communication between the attached sensor head and the fire alarm control panel (FACP) to adopt the same address as the detector, but as a unique device type on the loop. The FACP can then use that address to command an individual sounder - or a group of sounders - to activate. The command set from the panel can be tailored to the specific event, allowing selection of volume, tone, and group. In addition, some FACPs will enable custom tone patterns.t The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables it to be used as a component of the general evacuation signal - along with other System Sensor horns, horn strobes, and chimes -when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. The B2005 series offers several key advantages. The sounder base employs a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and simplify installation. The housing also locks with the mounting plate using two retaining screws, for added tamper resistance. The B200S.LF low frequency sounder base is designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the most ideal to awaken sleeping occupants, even those with mild to Agency Listings severe hearing loss. LISTED APPROVED tRefer to the appropriate FACP manual for more information. S911 3035027 B200S 7135-1653 0213 B200S-LF 7300-16530238 Base Diameter 6.875"(17.46 cm) Base Height 2.0-(5.08 cm) less sensor Shipping Weight B200S: 0.50 lb. (227 gm); B200S-LF: 0.60 lb. (272 gm) Operating Temperature Range Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at systemsensor.com Operating Humidity Range 10% to 93% relative humidity (non-condensing) External Supply Voltage 16 to 33 VDC (VFWR) External Supply Standby Current 500 pA maximum Alarm Current 35 mA maximum at high-volume setting; 15 mA maximum at low-volume setting SLC Operating Voltage 15 to 32 VDC SLC Standby Current 300 pA maximum (base only, refer to applicable sensor specification) External Supply Voltage 16 to 33 VDC (VFWR) External Supply Standby Current 550 pA maximum AlCLitnt 1 High volume setting: 70 mA maximum @ 33.0 VDC - 190 mA maximum @ 24.0 VDC 1140 mA maximum @16.0 VDC Low volume setting: 115 mA maximum @33.0 VDC 20 mA maximum @ 24.0 VDC 25 mA maximum @ 16.0 VDC High Volume Greater than 85 dBA minimum - measured in a UL reverberant room at 10 ft. 24 Volts continuous tone) Low Volume Greater than 75 dBA minimum - measured in a UL reverberant room at 10 ft. 24 Volts (in continuous tone) SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©201 5 System Sensor. 5EILco Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change odtfrout notice. Visit systamseasor,com for current product information including the latest oerdon at this data sheet. www.systemsensor.com SP0S53602 • 02115 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0213 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: Models B2005 and B200SR detector audible sounder bases. Model B200S is capable of producing sound output in High and Low output with T3, T4, continuous tone, marching tone, and custom tone. Model B200SR can only be configured for T3 and continuous tone depending on the jumper setting. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices/detector bases for use with listes's separately listed compatible detectors. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2007 Edition. Refer to listee's Installation Instruction Manual for details. 05-14-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division POTTER PSN SERIES The Symbol of Protection POWER SUPPLY UL, cUL, CSFM Listed PSN-64 has 6 amps regulated with 4 Outputs PSN-106 has 10 amps regulated with 6 Outputs wwwwwl~ patent penning c®uS 0 LISTED 52930 735-0328:0189 Product includes a 5 year warranty Dimenions: 16 1/8W x 16 3/4"H x 3 1/2'D Stock Number: 3006436 PSN-64 Red Enclosure 3006437 PSN-106 Red Enclosure 3006446 PSN-106 Black Enclosure Outputs Rated at 3 amps maximum each May be configured as up to three class "A" Style "Z" notification circuits 3 amp, 24 VDC programmable output power Supervised Battery Charger: 27.3 @ IA (supports 7-55 AH batteries) Easy to install cabinet with leveling mounts and key lock Wiring knockouts provided on sides and top of cabinet Two Trouble Relays (5A at 30VDC) General System Trouble (programmable for AC delay) Low AC Trouble with optional delay settings Diagnostic LED's Status LED's for Active NAC and NAC trouble conditions Status LED's for Earth Fault (Amber),AC (Green), Battery Fault (Amber) Trouble Memory feature captures troubles which have previously restored Synchronized notification appliance circuits Potter/AMSECO®, Wheelock®, Gentex®, System Sensor® Configurable output circuits (DIP switch sets options for each circuit) 15 mA at 8-33 VDC input trigger Reference EOL allows 2K - 27K EOL value to be used Quadrasync provides panel wide synchronization of same or multiple brands PassThru mode allows the Outputs to match the Input Signal Electrical Specs: 120/240 VAC 50-60 Hz input 5.1 Amps @ 120 VAC or 2.5 Amps @240 VAC Battery Standby Current 75 mA Alarm Standby Current 75 mA* *ç external load Description The PSN series of notification power supplies offers reliable notification Sensor® strobe devices. Each output can be configured the same sync power with unprecedented versatility. The power supplies offer either protocol or set independently. 6 or 10 amps of continuous power through 4 or 6 outputs respectively. Each output is rated at 3 amps and it may be used continuously without any derating. The power supply operates on either 120 VAC or 220 VAC power input and has a regulated 24 VDC output. In addition, the panel can charge up to 55 AH batteries and leads the industry in housing up to 18 AH batteries. The cabinet is constructed out of 18 gauge cold rolled steel and has a durable red powder coat finish. In addition, a key lock is provided for securing the door. Ample electrical knockouts are provided on the sides and the top, allowing the installer options for running wires and maintaining the correct separations. The power supply offers an industry leading Quadrasync function that allows for multiple strobe circuits ofdifferent brands to be synchronized to flash at the same time. The panel can have four different brands each connected to its own circuit and all of the strobes flash together. Each output can independently be configured to provide one of four synchronizations or steady power. This provides unequivocal flexibility in new and retrofit installations. The panel can be configured to synchronize Potter/AMSECO®, Gentex®. Wheelock® and System In addition, the panel has an input PassThru mode allows the outputs to follow the input signal and sync up the input flash. The panel will recognize the type of input being supplied and pass this through to the outputs with the same pattern. This input pass through can be selected on each output independently. The power supply contains simple dipswitch programming and LED indications providing the installer indications of the operation and the ability to correct any faults. A Trouble Memory is provided to allow an installer to review past troubles and make the necessary repairs. Each output has an LED to pin point the exact circuit where a problem may have occurred. Relays are provided for monitoring the general system and AC failure. Each output and be independently configured for various applications and installations. Each output can be independently configured for Class A or Class B operation, constant power, ANSI Temporal Code 3, Single, Multiple or Combo Inputs or Door Holder Power. Potter Electric Signal Co., LLC • St. Louis, MO • Cust Service: 866-240-1870 • Tech Support: 866-956-1211 • Canada 888-882-1833. www.pottersignal.com PRINTED IN USA MKT. #89I00I3 - REV C2 PAGE I OF 2 11/12 .1. 1 POTTER PSN SERIES The Symbol of Protection POWER SUPPLY PSN-106 Wiring Diagram 120/240 VAC GND FAULT Jumper Position DETECT ENABLE ON OFF 120 VAC 50Hz-60Hz Black 240 VAC 50Hz-60Hz Gro -- Wt Connect to separate e unswitched AC circuit und Z'1- Ss LEDs d ;, . .'. , 0 go S7 'St E ED ,//////_ ____ Nil IüI HNG/ COMM I D7 0 0 II FlnWtemomcct. '-e-`y--`d'- S2 01:1 0 0 9 9 0 0 I 11 I —AC Power I - Low Battery I I Gad Fault El[I] F-1 _ Co EJ 8 Balk Options El NAC2 I NAM NAC4 NAC5 NACt .1 1— REF t1d1 1N2 0 - - - - + - + / /* ntI -tFflt IWO!. NC CO NO NC COMNO \ Battery + Battery - All ( / Li Li - Opliosut E.O.L Rnfrrrrscn non-power limited. Common relays are E.O.L. E.O.L. DC Power Trigger - -+ Battery connection (non-power limited). Note: PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power Use two (2) I2V batteries connected in series, supply is triggered. There is no current draw in Standby Mode. Engineering Specification The contractor shall supply and install the Potter PSN power supply. The power supply shall operate on either 120 or 240 VAC input. The panel shall be capable of continuous load power without any degradation to the main supply or the distribution board. The cabinet shall be capable of housing up to 18 AH batteries and the panel shall be capable of charging up to 55 AH batteries in an external cabinet. The panel shall have dip switches for simplistic configuration of the system and LEDs to provide visual indication to the installer of the status of the system. The dip switches shall allow for-AC power delay selection, Class A/B operation per output, Door Holder Power options, constant auxiliary power, trigger input type, ANSI Code 3 Temporal Code, Pass Thru (input tracking), Potter/AMSECON sync, Gentex Sync, System Sensor Sync or Wheelock' sync. The LEDs shall provide indication of communication between the power supply and distribution circuit assemblies. The LEDs shall have distinctflash patterns to provide further indication ofthe troubles present. The panel shall have selectable Trouble Memory to provide the installer an indication that a past trouble existed on a circuit for diagnostic purposes. Each output ofthe power supply shall be capable of 3 amps of continuous power without degradation overtime. The power supply shall provide for multiple circuits ofstrobe appliances. The power supply shall synchronize the flashes of any of the above listed strobe appliances on a per circuit basis. Up to four different strobe circuits may be connected and all of the strobes shall flash in unison as required by UL 864. In addition to this Quadrasync feature, the panel shall allow any of the four above mentioned sync patterns as an input and pass this signal through and synchronize the outputs to match the input flash pattern. 54 PRINTED IN USA MKT. 48910013 - REV C2 PAGE 2 OF 2 11/12 4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0328:0189 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Models PSN-106, PSN-64, PSB-10 Notification Appliance Circuit (NAC) Power Supply Units. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input 120/240 VAC 50/60Hz Output 24VDC @ IOA INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For fire alarm use, the unit must provide battery backup suitable for at least 24 hours. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply units for use with separately listed compatible fire alarm control units and notification appliances. Authority having jurisdiction should be consulted prior to installation. The unit can be programmed to generate the three-pulse temporal fire alarm evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 edition. 01-27-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6720:E FMM.1 (A), FMM.1 01(A), FZM-1 (A) & FDM-1 (A) Monitor Modules with FlashScan® General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4° [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM.1 (A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- NOTIFIER® by Honeywell FMM-1(A) (Type H) open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120° F (0°C to 49°C). Humidity range: 10% to 93% noncoridensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:E• 07/30/2015 - Page 1 of 4 FMM.1 01(A) Mini Monitor Module Temperature range: 32°F to 120'F (0°C to 49°C). Built-in type identification automatically identifies this Humidity range: 10% to 93% noncondensing. UVIL# 00 0 II UI IIL'JI II I'JUUIO LU LI IC F." u. $ Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01— 99 on CLIP loops. 14 ADDRESS 0 1 12(((\3 3 LOOP 4 137,>l \2 _____ (2 8 76 8 76 10 5_ 5 I TENS ONES II- o uj 0 O • —J O cc w Co The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max!,(Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Dimensions: 1.311(3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on FlashScan loops, 01 - 99 on CLIP loops. LED flashes during normal operation; this is a program- mable option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Page 2 of 4— DN-6720:E .07/30/2015 Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM.1(A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32" to 120"F (0" to 49"C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1 (A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1(A) is set to address '26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635. ULC: S635. FM Approved. CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. MEA: 457-99-E. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). Fire Dept. of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM.1(A): Monitor module. FMM.101(A): Monitor module, miniature. FZM-1 (A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:E • 07/30/2015 - Page 3 of 4 FlashScan® and NOTIFIER® are registered trademarks and FireWatchlM is a trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 4 of 4— DN-6720:E •07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of I CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division