Loading...
HomeMy WebLinkAbout2819 LOKER AVE E; ; AS160301; Permit12/8/2020 AS160301 Permit Data City of Carlsbad Sprinkler Permit 2819 LOKER AV Job Address: EAST Permit Type: SPRINK Parcel No: 2090831600 Lot #: 0 Permit No: AS160301 Status: ISSUED Applied 9/19/2016 Approved: 10/6/2016 Reference No.: Issued: 10/6/2016 PC #: Inspector: Project Title: TITLEIST LOKER BLDG. TI FOR EXISTING WAREHOUSE SPACE INTERIOR WALLS FOR ROBOT CLUB TESTING Applicant: PACIFIC FIRE SYSTEMS, INC. 13142 NELSON LANE POWAY, CA 858-722-9865 Owner: CANOGA-RINCON LOKER INDUSTRIAL INC DEPT #207 P 0 BOX 4900 SCOTTSDALE AZ Fees ($) Add'I Fees ($) Total ($) Balance ($) 303 Ir 0 303 0 1/1 MATERIAL DATA SUBMITTAL TITLEI ST LOKER BUILDING Tenant Improvement 2819 LOKER AVE. EAST CARLSBAD, CA 92010 Pacific Fire Systems, Inc. 12316 Oak Knoll Rd. Suite B Poway, CA 92064 (858) 883-2333 Phone • (858) 883-2334 Fax AS 1 60301 2819 LOKER AV EAST ft 1I4 8019957 SWIG 200 1/4 x 2" 172 (Fit) 25 1c'- 802057 SWG 10 /14 X 1622 (Fir( 303 25 IZ5 38 8021957 SWO 20 114 x 2 - 1725 (Fir) 052 25 125 18' 8073925 SVVG 20 SS u4 a 2' 1725 IFi 1 850 25 /25 8022925 SWG 25-380 2-1,!2r,2249 (Fin) 1500 25 125 0 8023925 SWG30 3 1894 (Fir) 25 125 1 414 SW Red Nut Jiver Part # 8114910. May require pre-drilling; consult jo/at manufacturer. JMMYS L7J'1ff*UII1I i.I4*t1JTt4 Not less tar 2 nominal width • No pre-drilling required. (1-112') up to 3-1 T pipe not less than - 3(2-112') ncmin it width 4 & 5 pipe Quick to install using the Sammy I Floor Joist Nut Ddver with an 18V cordless Minimum 2-10 from bottom for drill/driver. Tom - branch lines. Minimum 3 from hot- tom for main lines. Exception This • Saves time from traditional - requirement shall not apply to Z or methods, thicker nailing strips resting on top of steel beams. Reduces installation costs. 'Manufactured in the U.S.A. xutc" a idea de,r.riiaturuan at www.itwbulldex.com 'Manufactured in / - 414 Black -- Size Aumber uiimiri.]iIaI11Iri111Ill ct'tA:Icti1aI2 ffB_L- Nut Driver -[ ' 3/9" 91QQ57 S ,.Cs 20 1/402" 1257 (Fir) 1050 Part #811.3910 r 1903 Dim. Lum~e~ 1500 I 8269957 ' - 1T20 516 xl 4 145 @ 45 aff vertical Dim Lumber 903 Dim. Lumber j 1.... tO" 8303957 SH-GST/CST2,0 51160-3/4" 1406 @45'sff vertical Dim. Lumber - May require pre-drilling; esnsutt jsist manufacturer. #14 u'l Omrq 'Fat river P'rt b 827391 (1 Size Range - Secures 3/8 thru 7/8" rod in 1 'increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Rod Max. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Fig. 98- Rod Stiffener Fig. 98B - Rod Stiffener w/Break-off Bolt Head Size Range - Secures 3/8 thru 7/8 hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized oie - Available in FiDu finish or Stainless Weel riiaLeiktis. Order By - Figure number Component of State of California OSHPD Approved Seismic Restraints System FIG. 98 FIG. 98B Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 11/2 ' rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Fig. 100- All Thread Rod Full Lnnth Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F WtJ100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com j Fig. 200 - "Trimline" Adjustable Band Hanger Fig. 200R (Import) — "Trimline" Adjustable Band Hanger w/Retainer Ring Size Range - 1/2' thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is eas- ily installed around pipe. (21/2" thru 8") Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nub. Order By - Figure number and pipe size Note - Figure 200R (import) with retainer ring and non-captured knurl nut. Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/s 2/B 400 11 3/4 3/8 8mm or 10mm 3½ 21/2 400 11 1 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 1112 3/8 8mm or 10mm 3/8 2/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/a 41/8 600 27 3 3/8 10mm 5/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 8Y4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92679 • PH: 951.7375599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com H DynamThread 0 Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. @UOL <S> Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologicafly Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA- 13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) PcW WI/lift (21') WI/Lift (24') WI/lift (251) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.080 1.330 1.75 70 1955 2234 2327 25' 27.4 2.0 2.60 70 887 1013 1056 14 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11/s 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 1143 2 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 16100 S. Lathrop • Harvey, IL 60426 Customer Service: NCO Qr ollied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 a vital part of your world TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3 -3 SMITH - COOPER <@> INTERNATIONAL Ductile Iron Threaded Fittings C ® US * ALL FITTINGS 100% AIR TESTED * ASME/ANSI B16.3 4 FM * ISO 9001:2000 MANUFACTURER * ASTM A536 Grade 65,45,12 LISTED * LISTED(APPROVED AT 500 PSI * ASME/ ANSI B 1.20.1 APPROVED fliwlil,' lrnn l4iill '1pid Ti.* Figure 358T - - 3/4 x 3/4 x I 14 1.45 TY 0.681 I x I x 1-1/4 1.67 1.67 1.58 0.97 1x1x1-1/2 1.80 1.80 1.65 1.14 1-1/4 x I x 1-1/2 1.88 1.80 1.82 1.43 1-114x1-114x1-112 1.88 1 1,881 1.82 1.52 1-1/4 x 1-1/4 x 2 2.10 2.00 1-1/2 x1-114x2 2.16 2.1 1.94 -1/2 x 1-1/2 x 2 2.16 2.1 2.1L 202 2.00 12 x 2 x 2-1/2 TY MiMlp Irnn 3.Tpv Røilticbitt Cniinlino Figure 35RC Size WT 1 A 1 x 1/2 1.69 0.40 1x314 1.69 0.38 1-1/4x3/4 2.06 0.53 2 x 1(not hex) ii 0.3 TI"efilp Tmn Cq,a & RpwkwCmia Figure 35X Size A .; B 1 11-1/2 1.50 1.50 0.97 1-1/4 1.76 1.75 1.59 1.94 1.94 1.89 2 FiRum 35RX - Size 1-1/4x1 1.67 1.58 1.25 1-1/2 x 1=8 1.3 .48 2x1 F)iwHlo lrnri Phicra Figure 35SP - Size A WF /2 0.94 0.10 2 1.5010.90 Y'hte#41a lynn Py4iw4,aa Tan Fioiir .cRT Size -- A - 8 - C - 3/4x3/4x 1/2 1.20 1.20 1.22 0.46 1x1l2x1 1.50 1.38 1.50 0.70 I x314x314 1.38 1.31 1.45 0.68 s 3/4 x I 1 : i :- T TY I x I x 1/2 1.26 1.26 1.36 066 iii x 3/4 i3 T 0.73 /4x1/2x1-1I4 1.7' 1.75 1.04 1-1/4 x 3/4 x 1-1/4 1.75 1.62 1.75 1.09 1-1/4 x 1 x 1/2 1.34 1.26 1.531 0.81 1-1/4x 1 x3/4 - 1.451 1.38 1.63 0.90 1-114x 1 x 1.58 1.50 1.69 1.03 1-1/4x I x1-1/4 1.75 1.69 1.75 1.10 1-114x -1/4x112 1.34 1.34 1.53 0.87 1-1/4 x 1-1/4 x 314 1.45 1.45 1 1-1(4 x 1-1/4-x I TI T. -1.671 TT 1-1/2 x 1(2 x 1-114 'TIT 1 1.56 1.881 1.'7 -112 x 1/2 x 1-1/2 1.94 1.66 -1.941 1.42 -1/2x3/4x1-1/4 1.94 1.66 1.881 1.42 -1/2x314x1-112 1.94 1.75 1.941 1.47 -1/2 x I x 1/2 1.44 1.25 1.69 0.97 -1/2x1x314 1,501 1.44 1.75 1.14 - x 1.651 1,5o T 1T -1/2xlx1-1/4 1.82 1.67 1.88 1.47 x 1-1/2 1.94 1.80 1.94 1.52 x 1/2 741 1.34 1.66 1.031 1-1/2x1-1/4x3/4 1.52 1.45 1.75 1.10 1-1/2x1-1/4x1 1.65 1.58 1.80 1.31 1-1/2x1-1/4x1-1/4 1.82 1.75 1.88 1.52 1-172-XT--1/4 x 1-1/2 i.V4'--I.W -TR 1.5 1-1/2 x 1-1/2 x 1/2 1.41 1.41 T -1.14 1-1/2x1-1/2 x3/4 1.52 1.52 1.75 1.23 1-1/2x1-112x1 1.65 1.65 1.80 1.38 1-1/2x1-1/2x1-1/4 -1-82 1 1.88 1:3 2x1x2 1 7 T' 2x1-1/4x2 2.25 2.10 2.25 2.31 x 1-1/2 x 1/2 T TT TSN8 1.3 xl- 1/2 x 3/4 1.60 1.3 T7 TT 2x 1-1/2x 1 1.73 1.65 2.02 1.85 2x1-112x1-1/4 1.90 1.82 2.10 2.03 2x1-1/2x1.1/2 2.02 1.94 2.16 2.37 2x1-112x2 2.25 2,16 2.25 2.53 2x2x1(2 1.49 1.49 1.88 1.50 x 2 x 3/4 1.60 1.60 TF 1.7 2 x 2 x 1 1.73 1.73 2.02 1.91 2x2x1-1/4 1 1.90 1.90 2.10 2.05 2 x 2 x 1-1/2 1 2.02 1ö 2.16 TIT 4i SMITH - COOPER INTERNATIONAL <@> U S Ductile Iron Threaded Fittings C nUL * ALL FITTINGS 100% AIR TESTED 5 4E / ANSI B16.3 FM * ISO 9001:2000 MANUFACTURER * ASTM A536 Grade 65,45,12 <~M> USTED * LISTED/APPROVED AT 500 PSI * ASME/ANSI B 1.20.1 APPROVED fliwtilp imn 400 P11mw Figure 35E Size A Wat I T + i71 im 0.24 1 J} 1 1.50 0.64 1 7 ii äi 1-1/2 1.94 1.24 2 2.25 1.74 fltu41i tm,. 'W P16- Fig= 35RE Size N Y WT ? L- 1' $ /4x1/2 1.22 1.20 0.33 xl/2 1.36 126 0.44 x314 1.45 1.38 0.53 -1/4 x1/2 1.53 1.34 0.64 -1/4 x 314 1.63 1.45 0.75 -114x1 1.67 1.58 0.77 -1/2 x 1/2 -M-7-52 -1/2 x 3/4 1.75 1.52 0.95 -1/2x1 TäÔ 1 * -1/2 x 1-1M T.88 iB ii x112 1.97 1.60 1.35 2x314 1.97 1.60 1.39 x 2.02 1 1.73 1.58 2x1-1/4 2.101 1.90 1.62 xl-1/2 2.16 2.02 1.67 2-1/2 x 1-1/2 2.51 2.16 2.32 2-1/2x2 Tö W T fliwfile Irnn Erms Saat Uninn Figure 35U SLZe • 1 1-1/4 L I I J.t 1/2 I f314 19 F2.00O.66 1.08 ________ i 1-1/2 2.82 2.03 2 fliwfila lrnn ('ni,nlino Pigs.ue35CP Size A I I I A 1/2 3/4 1.38 1.75 1.63 P0.44 1-1/4 iö 1-1/2 2.19 2.62 1.15 fliwHle Iron Can Figure 35C Size A Liu + t 3/4 4 A 1/2 0.87 0.15 0.97 0.22 1 1.16 0.33 1-1/4 1.28 04 1-1/2 1.33 0.68 2 1.45 0.96 2-1/2 1.701 TO Ductile fran Hex 8hiRhin Figure 35HB Size T Wgt lx 1/2 1.06 0.22 1x314 1.06 0.18' 1-1/4x1 1.19 0.31 1-1/2 x 1 1.25 0.53 1-112x1-114 1.25 0.35 2 x 1 1.38015 2x1-1/4 1T3T 69 2x1-1/2 T _0M2 fl.I11ø Irnn ic° I1hnw Figure 35F -ste AJ I ________ 1/2 0.88 0.22 A " 3/4 08 1 1.13 0.48 1-1u 1 T 29 0.73 - 1-1/2 T -- 2 1.69 1.55 -,j 2-1F2 I -iT 27 Ductile hon Beam Clam 'Size I A I WgL 13/8 I 0.75 I 0.31 NGSTM oc ct per'c ns Hole-Cut System MODEL V-723 SADDLE-LET (Small Mechanical Tee) p__C_1 B The Model 723 Saddle-Let is the ideal outlet fitting for direct connections to sprinkler " "- -1' - 5 heads, drop nipples and or gauges. No need for welding, just cut or drill a hole at the - A .. desired outlet location Position the Saddle-Let so that the locating collar fits within the hole and secure with the U-bolt and nuts. The Saddle-Let comes with a standard black finish or as an option can be supplied electro zinc plated or painted orange. The Saddle- Let allows full bore flow and is pressure rated to 300 psi (20 bar). c®us <@> LISTED APPROVED Hole Dia. 0' seiisions-nrrs[n Take-Out Nominal Size T Bolt Size Bolt Torque Weight mm/in +1.6,-01+0 , 063, -0 mm/In B C mm/In in N-M/Lb-Ft Kgs/Lbs 32 X 15 30 510 89.0 5610 35,0 318a 20 30 04 1,25 05 1,13 208 3,55 2.2.01 13B 15 22 09 32 0 20 30 53.0 89.0 56.0 35.0 3/8e 20-30 0.4 1.25 x 0.75 558 2.08 5,50 2.20 138 U-Bolt 15 -22 0.9 32 x 25 30 56.0 89,0 56.0 38.0 3/8o 20-30 0.4 1.25 X 1 1.18 220 1 3.50 2.20 1,50 U-Bolt 15-22 0.9 40 X 15 30 55.0 89,0 56.0 35.0 3/8o 20-30 0.4 55 x0.5 1.18 216 3.50 2.20 1,38 U-SpIt 15' 12 0.9 40020 30 55,0 89.0 56.0 35,0 3/80 20-30 0.4 1.5 00.75 5.18 2.16 3.50 7.20 1.38 U-Bolt 15-22 0.9 400 25 30 58.0 89.0 56,0 38.0 3/80 20-30 0.4 1.5 x 1 1.18 2,28 3.50 2.20 1 1.50 U-Bolt 15 -22 0.9 50 x 15 30 64.0 98.0 56.0 42.0 3/80 20-30 04 200.5 1.18 251 3.85 220 165 '• U-Bolt 15-22 0.9 500 20 30 64.0 98.0 56,0 42,0 3/80 20-30 0,4 2 o 0.75 1.18 ' 231 3,85 2.20 1.65 u-Bolt 15-22 0.9 50025 30 67.0 98.0 56.0 45.0 3/80 20 '30 0.4 2 xl .1.18 2.63 3.85 2.20 1.77 U-Bolt 15 -22 0.9 65 x 15 30 69.0 111.0 56,0 51,0 3/8e 20-30 0.4 2.5 X,0,5 118 271 . 4,37_ 2,20 2.00..,.. U-Bolt 15-22 0.9 65 x 20 30 69.0 111.0 56,0 51.0 3/80 20-30 0.4 2.5 x 0.75 1,18 2.71 4,37 2.20 2.00 U-Bolt 15-22 0.9 65 025 30 72.0 111.0 56.0 54.0 3/8e 20-30 0.5 2.5 x 1 1,18 2.83 4,37 2.20 2.13 U-Bolt 15-22 11 Hole diameters listed are suggested (sole saw diameters. '1: Take-out (Center of run to end of pipe to be engaged) Trusted above all.TM 25 NIKJNG*