Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
6042 GATEWAY RD; ; FPC2018-0247; Permit
I 14iIl11 11]41 ( ity of Carlsbad Print Date: 10/19/2021 Permit No: FPC2018-0247 Job Address: 6042 GATEWAY RD, CARLSBAD, CA Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: Track U: Applied: 07/30/2018 Valuation: $0.00 Lot U: Issued: Occupancy Group: Project U: DEV12023 Finaled Close Out: 07/29/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: UPTOWN BRESSI RANCH Description: UPTOWN BRESSI - UNDERGROUND BLDG #19 Applicant: FPContractor: CAL-WEST FIRE PROTECTION SPECIALIST CAL-WEST FIRE PROTECTION GONZALO PENA 8361 COMMONWEALTH AVE 8361 COMMONWEALTH AVE BUENA PARK, CA 90621-2525 BUENA PARK, CA 90621-2525 (714) 912-4552 (714) 912-4552 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $625.00 Total Fees: $625.00 Total Payments To Date: $625.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov fft~q-D 1 o24 - - - Fire Protection by Computer Design Cal-West Fire Protection 1113 N Gates St. Santa Ana, Ca. 92703 866-374-9378 Job Name : Uptown Bressi "Bldg. #19" Building Location : El Fuerte St. & Gateway Rd. System Contract : 18-099 Data File : Bldg. - 19.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C Cal-West Fire Protection Page Uptown Bressi "Bldg. #19" Date 7.19.18 City Water Supply: Demand: Cl - Static F5ressure : 100 Dl - Elevation : 1.516 C2 - Residual Pressure: 20 D2 - System Flow : 500 C2 - Residual Flow : 2500 D2 - System Pressure : 23.702 Hose ( Demand) D3 - System Demand : 500 Safety Margin : 72.224 150 140 130 p120 R11° E10° -... S90 S 80 U 70 R6° E 50 40 30 - - D2 20 _ 10 ; _ 30600 900 1200 1500 1800 2100 2400 2700 FLOW( N"1.85) Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary Cal-West Fire Protection Page 2 Uptown Bressi "Bldg. #19 Date 7.19.18 Fitting Legend Abbrev. Name 1/ "h 1 11/4 1% 2 21/2 3 3Y2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 1390 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zif Febco 876V Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 Pressure / Flow Summary - STANDARD Cal-West Fire Protection Page 3 Uptown Bressi "Bldg. #19 Date 7.19.18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reri BOR 0.5 0.0 na UG1 -3.0 2.89 na UG2 -3.0 11.73 na UG3 -3.0 20.32 na SRC -3.0 23.7 na The maximum velocity is 12.15 and it occurs in the pipe between nodes UG2 and UG3 500.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 Firal Calculations - Hazen-Williams Cal-West Fire Protection Page 4 Uptown Bressi "Bldg. #19" Date 7.19.18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BOR 500.00 4.26 E 13.167 12.000 0.0 Qa = 500.00 to 120.0 0.0 13.167 1.516 UG1 500.0 0.0545 0.0 25.167 1.372 Vel = 11.25 UG1 0.0 4.23 4E 76.893 160.000 2.888 to 150.0 0.0 76.893 0.0 UG2 500.0 0.0373 0.0 236.893 8.846 Vel = 11.42 UG2 0.0 4.1 3E 49.537 10.000 11.734 to 150.0 Zff 0.0 49.537 6.000 * * Fixed Loss = 6 UG3 500.0 0.0435 0.0 59.537 2.588 Vel = 12.15 UG3 0.0 4.23 E 19.223 29.000 20.322 to 150.0 G 3.845 61.514 0.0 SRC 500.0 0.0373 T 38.446 90.514 3.380 Vel = 11.42 0.0 500.00 23.702 K Factor = 102.70 Computer Programs by Hydratec inc. Revision: 50.52.1 FBH H A H WAFER CHECK VALVE WEIGHTS 4 6 8 Lb 15.75 22.50 36.50 Kg 7.14 10.21 16.56 C-1 WAFER CHECK VALVES [Mueller Co1 U L I FM Rev. 2-03 FIRE PROTECTION PRODUCTS A-21 02 Wafer Check Valve 4', 6, 8" 175 psi (1207 kPa) Working Pressure 350 psi (2413 kPa) Test Pressure Listed by Underwriters Laboratories, Inc. and Approved by Factory Mutual Research Corporation. PARTS LIST Catalog Parts Number Description Material Material Standard CW-1 Seat Ring Cast Bronze ASTM B584 CW-2 Body Cast Iron ASTM A126 CW-3 0-Ring (2 req'd) Buna-N ASTM D2000 CW-4 Clapper Cast Bronze ASTM B584 CW-5 Bushing (2 reqd) Brass ASTM B16 CW-6 Spring Stainless Steel Type 302 CW-7 Hinge Pin Stainless Steel Type 303 CW-8 Seal, Seat EP Rubber ASTM D2000 CW-2 CW-1 CW• DIMENSIONAL INFORMATION FOR WAFER CHECK VALVES Size DIMENSIONS In. A (mm) In. B (mm) C In. (mm) In. D (mm) In. E (mm) 4 3.75 (95) 1.34 (34) 6.88 (175) 3.00 (76) 4.03 (102) 6 3.75 (95) 1.53 (39) 8.75 (222) 4.56 (116) 6.06 (154) 8 4.25 (108) 1 1.92 (49) 1 11.00 (279) 1 6.00 (152) 1 7.98 (203) WAFER CHECK VALVE ORDERING INFORMATION Specify: Quantity, Size and Catalog Number. WAFER CHECK VALVE PARTS ORDERING INFORMATION Specify: Quantity, Catalog Number, Part Name, Size of Valve, Catalog Number of Valve and Year Date of Valve. Page C-1-6 No. 135 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Sprouts Farmers Market SR#: PROJECT ADDRESS: 6217 El Fuerte St (Assigned upon plan submittal) CITY: Carlsbad PHONE: ( 714) 914-4552 (Cal-West Fire) FAX NUMBER: ( 714 ) 912-4641 Largest Building (ft.2): 26,000 Sprinkled? Yes Construction Type: LINK SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): El Fuerte St north of Gateway Rd TEST INFORMA TION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 129 PSI Hydrant Number (if applicable):H20910 Elevation of test: 402 Feet Main Size: 24 INCH Pressure Zone 700 Feet Date/Time of Test Pitot Tube Reading PSI Corresponding Flow:GPM Total Flow: 8,000 GPM Residual Pressure 110 PSI At peak demand , this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Title/Org(joiectManager Date: 01/11/2018 4. I N & Legend I w_Hydrant Pipe ZONE -550 -700 30- 30. 8. I 2L 12 L LEIGHTON CR 00 8' L*RTING TON WV ct 11 WN GARDEN RD Fire Flow Test F-1 Location H20910 --~ATEWAYRD 12" 12" Sprouts Farmers Market - Fire Flow Analysis MJ Accessories ANSI/AWWA C111/A21.11 B.C. BI I I;. JISJRP;{S i'Ie1W.WD1 O.D.A B C BC I D BOLT HOLE BOLT QTY WT (LBS.) NOM SIZE 2 6.12 0.62 1.18 3.40 2.61 4.75 00.75 2 1 3 1.37 4.84 4.06 6,19 075 4 5 7.69 0.62 4 4 9.12 0.75 1.50 5.92 4.90 7.50 00.88 6 6 11.12 0.88 1.63 8.02 7.00 9.50 00.88 6 10 9.15 11.75 00.88 6 14 8 1337 1.00 1.75 10.17 10 162 100 175 1.75 1222 14.32 1120 13.30 1400 16.25 0088 00.88 8 8 20 24 12 17.88 1.00 14 20.25 1.25 2.00 16.40 15.44 18.75 00.88 10 45 16 22.50 1.31 2.06 18.50 17.54 21.00 00.88 12 55 18 24.75 1.38 2.13 20.60 19.64 23.25 00.89 12 55 21.74 25.50 00.88 14 20 27.00 1.44 2.19 22.70 66 24 31.50 1.56 2.31 26.90 25.4 30.00 00.88 16 90 30 39.12 2.00 2.75 33.29 32.17 38.47 36.88 43.75 50.62 01.13 20 220 36 46.00 2.00 2.75 39.59 01.13 01.38 24 28 286 288 42 53.12 2.00 2.75 45.79 44.67 48 6000 200 275 5209 5097 5750 01.38 32 400 tMj OVERSIZE GLANDS NOM. 0 D A SIZE HOLE B C I.D. c BOLT BOLT QTY WT (LBS) 4 9.12 0.75 1.50 5.92 5.10 7.50 00.88 4 3 6 11.12 0.88 1.63 8.02 7.20 9.50 00.88 6 5 8 13.37 1.00 1.75 10.17 9.40 11.75 00.88 6 6 10 1562 100 175 1222 1150 1400 0088 8 8 17.88 1.00 12 1.75 14.32 13 .60 16.25 00.88 8 9 16 22.50 131 2.06 1830 17.94 21.00 00.88 12 14 UCAT.I4.OI REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTS IV Page 15 HOUSTON CORPORATE TOLL FREE I-8OO.999-3)9 FAX ZSI.SSS-9ccO ww.spip.proJucNom JMagIe Building essentials for a better tomorrow' SUBMITTAL AND DATA SHEET PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) APPROX. WEIGHT (LBS/Fl) PRESSURE CLASS 165 psi (DR 25) 4 4.80 4.39 0.192 5.25 5.57 1.9 6 6.90 6.31 0.276 6.40 8.00 3.9 8 9.05 8.28 0.362 7.05 10.50 6.7 10 11.10 10.16 0.444 8.20 12.88 10.1 12 13.20 12.08 0.528 8.80 15.31 14.4 PRESSURE CLASS 235 psi (DR 18)* 4 4.80 4.23 0.267 5.25 5.87 2.6 6 6.90 6.09 0.383 6.40 8.43 5.3 8 9.05 7.98 0.503 7.05 11.06 9.2 10 11.10 9.79 0.617 8.20 13.57 13.9 12 13.20 11.65 0.733 8.80 16.13 19.7 PRESSURE CLASS 305 psi (DR 14)* 4 4.80 4.07 0.343 5.25 6.17 3.2 6 6.90 5.86 0.493 6.40 8.87 6.7 8 9.05 7.68 0.646 7.05 11.63 11.6 10 11.10 9.42 0.793 8.20 14.27 17.6 12 13.20 11.20 0.943 8.80 16.97 25.1 Consult JM Eagle" for CSA and other listing availability prior to shipment. Note: *FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14. * Contact your JM eagleTM sales representative for location availability. I.D. Inside Dameter O.D. : Outside Diameter T. : Wall Thickness D° Bell Outside Diameter E: Distance between Assembly Mark to the end of spigot. T I O.D. E Assembly Mark Product Standard: ANSI/AWWA C900 Pipe Compound: ASTM D1784 Cells Class 12454 Gasket: ASTM F477 Integral Bell Joint: ASTM D3139 Certifications: ANSI/NSF Standard 61 UL Standard 1285 Pipe Length: 20 feet laying length Installation: AWWA C605 JM Eagle' Installation Guide JM Eagle1M also manufactures this pipe in green for sewer force main applications and purple, specifically for reclaimed water systems. This pipe is made to the same requirements as our standard products. The only difference is that the pigment used is green or purple. These products will not be marked with UL or NSF listing marks. Additionally, the green pipe will be marked "Forced Sewer" and the purple pipe will be marked: "Reclaimed Water... Do Not Drink." For Non-Health Hazard Applications Job Name - Job Location Engineer - Approval - MasterSeries® LF876V Double Check Detector Backflow Prevention Assemblies (Type II) Size: 21/2" - 8" (65mm - 200mm) The FEBCO MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. This Backflow Assembly is primarily used on potable drinking water systems and fire sprinkler systems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal "N-Pattern" Installations Vertical-Up 'Z-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1st & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4' Backflow Assembly No Special Tools Required for Servicing Field Replaceable Seats & Discs Detect Potential Underground Water Leaks Detect Unauthorized Water Usage Contractor Approval Contractor's P0, No. Representative - Model LF876V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved ULJ FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by AWrNA Standard 0510. The auxiliary bypass line contains a 5/8"x3/4' Water Meter that complies with ANSI/AWrNA Standard 0700 coupled with an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of AW\NA Standard 0510 flow and pressure loss performance parameters. NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. IJI1,I Inquire with governing authorities for local installation requirements "The wetted surface of this product contacted by consumable water contains less than 0.25°h of lead by weight. FEBCO product specifications in U.S. customary units and metric are approsimate and are provided for reference only. For precise measurements, please contact FEBCO Technical Service. FEBCO reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequentty sold. A WAITS Brand Options - Suffix OSY: UL/FM Approved OS&Y Gate Valves [ANSI/AVWVA C515 Compliant] CFM: Totalizing Cubic feet/mm %x 3/4 Water Meter [ANSI! AW\NA C700 Compliant] GPM: Totalizing Gallons/min 5/a x 3/4 Water Meter [ANSI! AW\NA C700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4 LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4 LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer: FDA Approved [ASME B16.1 Class 125 & AW\NA Class D Range] Series 611 Valve Setter MJ x MJ - Mechanical Joint x Mechanical Joint [AW\NAC111!A21.11] MJ x FL - Mechanical Joint x Flange [AWA Cli 1!A21.11; ASME B16.1 Class 125/AW\NA Class D Range] FL x FL - Flange x Flange [ASME B16.1 Class 125 &A\MNA Class D Range] Materials Below is a genera] materials list of the Model LF876V All assemblies size 21/2" through 8 is similar in materials and construction. Please contact your local FEBCO Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external AWWA C550-90 Shutoff Valves: OSY resilient wedge gate valve A\MNA C515 (lJLIFM) Check Seats: Stainless Steel Disc Holder: Elastomer Disc: Spring: Clamp: Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [FCCCHR-USC] ASSE 1048 Listed **UL Classified [US & Canada] **FM Approved IAPMO/cUPC AVWVA Standard C510 Compliant End Connections: Compliant to ASME B16.1 Class 125 & A\MNA Class D Range **Assembly configured with UL/FM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL!FM approved configurations. Assembly Flow Orientation: Horizontal (N-Pattern 21/2 - 8) - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC Vertical Up (Z-Pattern 21/2 - 8) - Approved by FCCCHR-USC, ASSE, cULus, FM, IAPMO/cUPC 8 ® 4FM C 90 ssi, Approved C (j)us 1048 B64.5 Pressure - Temperature Max. Working Pressure: 175p5i (12.1 bar) Mm. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350psi (24.1 bar) Hydrostatic Safety Pressure: 700psi (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous 01 Stainless Steel Silicone Stainless Steel A\AMIA C606 Lf Dimensions - Weights Size: 21/2 ' - 8" Below are the nominal dimensions and physical weights for the Model LF876V size 21/2' through 8. Allowances must be made for normal manufacturing tolerances. Please,Asit our website to download a copy of this product's installation instructions, or contact your local FEB00 Representative for more information. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) I, Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V SIZE (DN) DIMENSIONS WEIGHT in. mm in. A mm B in. mm in. C mm 0 in. mm in. E mm F in. mm in. G mm in. H mm in. I mm J in. mm in. mm L in. mm OSY lbs. kg. 21/2 65 291/h 740 121h 318 61/4 159 251/4 642 171/2 445 13% 346 271/4 692 51/2 140 11½ 283 31/2 89 16% 416 11½ 292 216 98 3 80 291/h 740 121/2 318 61/4 159 253/4 654 17Y4 451 141/8 359 281/4 718 51/2 140 11½ 283 33/4 95 221/4 565 111/2 292 242 110 4 100 311/8 791 14 356 7 178 27Y4 705 1834 476 151h 394 31 787 6 152 11½ 283 41/2 114 231/4 591 13 330 347 157 6 150 351/4 908 16 406 8 203 32Y4 831 221/8 562 185/8 473 371/4 946 71/4 184 121/2 316 51/2 140 301/a 765 13 330 529 240 8 200 1 4O/i 1035 181/, 470 91/4 235 363/4 933 251/8 638 1 203/4 527 41½ 1054 8½ 216 1 14 356 1 63/4 172 373/4 959 141/2 368 827 375 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) Indicates weight of complete Backflow Assemblies with specified Gate Valves 6 1F876V psi Service Flow Rated Flow I I lit Rated Flew I 18 16 14 I I I 12 I I 2 IC Vi U 6 8 - _.l— — - - — 2 C I 0 200 400 757 600 860 1050 1200 2271 3785 7.5 11.4 1400 1600gpm 5300 1pm 17.0 fps 8' 1F876V psi 18 16 14 0 10 iE 12 400 860 1200 1500 2000 2400 gpm 1514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 fps Service Flow Rated Flow Ill Rated flow Performance Row capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.5fps. AVW\IA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than 1 Ofps. UL flow rate is determined by typically rated Velocity of 15 feet/sec. Capacity N-Pattern trr 2W' 1F876V psi Service Flow Rated Flow lii Rated Flow 22 20 I I 18 I I 16 I I I 14 I I I E, 12 I I C 10 - -- -I I 2 I 0 L I 0250 75100125150170200225250275300325350gpm 264 568 852 1136 1pm 7.5 14.7 22.0 fps 1F876V psi Service Flow Rated flow Ill Rated Flow 22 - 20 I - 18 I - ( 16 - 14 I - Vi '12 0 50 150 150 200 250 300 350 400 450 500 gpm 379 757 1136 1514 1pm 75 14.5 22 fps LF876V psi Service Flow Rated Flow *UL Rated Flow 18 - 16 14 - la 2-9 10 - 8 -- - 2 0 - .1—. too 200 300 400 550 600 700 500gpm 379 1136 1893 2650 1pm 7.5 12.8 19.1 fps Pipe Support (furnished by customer) i!fl for valve weight only. vertical Orientation "Z-Pattern" Flow Curve Z Standard Orientation N-Psllem Flow Curve N A WATTS Brand ES-F-LF876V 1515 USA: Tel: (800) 767-1234 • Fax: (800) 788-4491 • FE8000nhine.Com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • FEBCOonhne.ca Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEBCOonline.corn 2017 FEBCO ES-A-lnBuildingRiser Series IBR In-BuildinEr Risers Sizes: 4 - 10 (100— 250mm) = A M E S FIRE & c 1551 CAP Of OWIN: Features Cost savings Corrosion resistant stainless steel construction, type 304 Ease of installation and light weight allows one person to position and handle the riser Minimal site preparation; joint restraint one-piece construction reduces time and labor; no missing parts, no leaks; easily identifiable for approvals Includes Test Cap and Coupler ULIFM approved Sizes: available in 4 - 10" (100-250mm) with various lengths to meet all local requirements Designed to meet NFPA 24-2007 Section 10.6.5 AWWA C900 Inlet/DIP AWWA C606 Outlet Job Name Job Location Engineer Approval Series IBR In-Building Risers are used to connect the main fire supply to the building overhead fire system. The fitting passes under the foundation without joints and extends up through the floor. Provided with installation tabs, the unit has a CIPS (Cast Iron Pipe Size) coupler for easy connec- tion to the underground supply (AWWA C900 PVC and Ductile Iron Pipe) and industry standard grooved-end connection (AWWA C606) on the building side for easy connection to the overhead fire sprinkler system. Ames In-Building Risers are precision engineered and manufactured to provide exceptional reliability and reduce installation time & labor costs associated with field assembly. In accordance with NFPA 24-2007, the UL/FM approved In-Building Risers replace numerous fittings, elbows & spools and reduces the possibility of leaks or failure in comparison to traditional installation methods and materials. Factory tested integrity ensures the highest quality installation. The use of stainless steel signifi- cantly increases the reliability and life of the riser. *The wetted surface of this product contacted by consumable water contains less than one quarter of one percent (0.25%) of lead by weight. Contractor Approval Contractors P.O. No. Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Mien reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Horizontal End: Mates with Ductile Iron Pipe and AWWA C900 Pipe (PVC Pipe with Ductile Iron Pipe Equivalent OD's) Utilizes Gasket conforming to UL 157 with "Lock in" gasket configuration class 1920 HKQA (4-10) Specifications In-Building Riser shall be installed as indicated on the plans. Riser shall be composed of a single extended 90 degree fitting of fabricated 304 stainless steel tub- ing, maximum working pressure 200psi (14 bar). The fitting shall have a grooved-end connection on the outlet (building) side and a CIPS coupler on the inlet (underground) side. The grooved end shall include a coupler and cap to facilitate testing of the underground piping. The In-Building Riser shall be an Ames Fire & Waterworks Series IBR. Approvals Fittings FM UL @ Us L Dimensions - Weights I-+--- A Grooved End J (Flange Optional) ClPS Coupling H9- Bracket C in. mm A(OD) in. mm ft B cm C ft cm lbs. kg 4 100 4½ 114 6 183 6 183 71 32 6 150 65/8 168 6 183 6 183 98 44 8 200 1 8% 219 1 6 183 6 183 129 59 10 250 1 103/4 273 1 6 183 6 183 202 92 Consult factory for custom leg dimensions. Standards NFPA - Designed to allow the contractor to conform to NFPA 24-2007 Section 10.6.5: Where a riser is close to building foundations, under- ground fittings of proper design and type shall be used to avoid pipe joints being located under the foundations. NFPA24-2007, 10.1.1, 10.6.7 End Connections N1ij MIIi(ltJ1I1i in. mm in. mm 4 100 4.8 122 6 150 6.9 175 8 200 9.1 230 10 250 11.1 282 Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe Meets AWWA C-207 class D for flanges Ratings Meets AWWA C-gOD pressure class 200, DR 14 Pipe Testing Welds are 100% leak tested at the factory SIZE in. mm DESIGN PROOF PRESSURE psi bar 4 100 1000 70 6 150 1000 70 8 200 800 56 10 250 800 58 IMPORTANT: Inquire with governing authorities for local installation requirements. A __ A M E S Ii.19OO1 -2000 FIRE &WATERWORKS www.amesfirewater.com Li Ri IF I ED A Watts Water Technologies Company USA: Backflow- 1427 N. Market Blvd • Suite #9 • Sacramento, CA 95834 • 1:916-928-0123 • F: 916-928-9333 Control Valves- 18550 Hansen Road • Houston, D( 77075 • 1: 713-943-0688 • F: 713-944-9445 Canada: 5435 North Serice Rd. • Burlington, ONT. L7L 51-17. 1: 905-332-4090 • F: 905-332-7068 ES-A-ln Building Riser 0935 © 2009 Ames Fire & Waterworks / PACIFIC STATES CAST IRON PIPE COMPANY DIVISION OF MOWANE. INC. P.O. BOX 1219, PROVO, UTAH 84603 TELEPHONE (AREA CODE 801) 373-6910 zw STANDARDS In each of the following, standards are developed by committees consisting of consumer, general interest and manufacturing members: American National Standards Institute (ANSI) American Water Works Association (AWWA) American Society for Testing and Materials (ASTM) Underwriters Laboratories (UL) MH16433(N) National Fire Protection Association (NFPA) National Sanitation Foundation (NSF) 61-1989 Factory Mutual (FM) J12V0A8.AH For ready reference, standards for ductile iron pipe are listed below: Standard Designation ANSI/AWWA C150/A21.50 ANSI/AWWA C151/A21.51 ANSI/AWWA C11O/A21.1O ANSI/AWWA Cl 53121.53 ANSI/AWWA C111/A21.11 ANSI/AWWA C115/A21.15 ANSI/AWWA C104/A21.4 ANSI/AWWA C1051A21.5 & ASTM A674 ANSI/AWWA C600 ASTM A746 NFPA Outside Protection 24 Subject Covered Design Water Pipe Fittings - Cast Iron Fittings - Ductile Iron Rubber - Gasket Joints Flanged Pipe Cement - Mortar Linings Polyethylene Encasement for Ductile Iron Pipe Installation Gravity Sewers Fire Protection Piping Pacific States ductile iron pipe meets and exceeds the requirements of all of the above national standards relating to pipe manufacture and performance. PACIFIC STATES CAST IRON PIPE COMPANY DIVISION OF McWE, INC. P.O. BOX 1219, PROVO, UTAH 84603 TELEPHONE (AREA CODE 801) 373-6910 FAX: (801) 377-0338 EMAIL: sales@pscipco.com WEBSITE: www.pscipco.com PscIPco 4& Thickness, Dimensions and Weights of Mechanical Joint Ductile Iron Pipe by Size for Each Thickness. Nominal Wt. of Barrel Mechanical Joint Wt. of Wt. Per Avg. Wt. Thickness Thickness OD* Per Ft. t Bell Lgth.j Per Ft4 Size Class In. In. Lb. Lb. Lb. Lb. 3 53 .31 3.96 10.90 11 230 11.4 4 53 .32 4.80 13.80 16 290 14.6 6 53 .34 6.90 21.40 18 405 22.4 8 53 .36 9.05 30.10 24 565 31.4 10 53 .38 11.10 39.20 31 735 40.9 12 53 .40 13.20 49.20 37 925 51.3 tincluding bell; calculated weight of pipe rounded off to the nearest 51b *Tolerances of OD of spigot end; 3-12 in. ±0.06 in. Including bell; average weight per foot, based on calculated weight of pipe before rounding. ,, ) ;*::. Visit our website at www.kennedyvalve.com K KENNEDY VALVE A DIVISION OF MCWANE, INC I ASSOCIATED WITH AWWA, NSF AND IJLFM ......................... :: C-509 FULL BODY c4$T IRON RESILIENTWEDGEYALVE ............. ... . . [•] 1)1 iY During the decade of the 1980's, the waterworks industry was introduced to the Resilient Seated Gate Valve, a design principle that is dominant in preference for use in distribution systems. Kennedy Company was at the forefront in this industry-wide movement by introducing the Ken Seal Series, our AWWA C509 Resilient Seated Gate Valve. In 2002, with the end user in mind, Kennedy redesigned the Ken Seal Series introducing the model KS-FW. The goal of the redesign was to eliminate the customer need for any anti- rotational bolts. Kennedy did this by designing a machined elliptical boithole in place of an as-cast opening. This elliptical design allows valve installers to slide a standard sized bolt into the slot, therefore eliminating the need to have two different types of bolts on the installation. RECOMMENDED SPECIFICATIONS FOR C-509 CAST IRON RESILIENT WEDGE GATE VALVES KENNEDY VALVE COMPANY Valves shall conform to the latest revision of AWWA Standard C-509 covering resilient seated gate valves for all water supply service. The valves shall have a cast iron body, bonnet, and 0-ring plate. The wedge shall be totally encapsulated with rubber. The sealing rubber shall be permanently bonded to the wedge per ASTM D429. Valves shall be supplied with 0-ring seals at all pressure retaining joints. No flat gaskets shall be allowed. Blind bolts shall not be allowed. The valves shall be either non-rising stem or rising stem, opening by turning left or right, and provided with 2" square operating nut or a handwheel with the word "Open" and an arrow to indicate the direction to open. Stems for NRS assemblies shall be cast bronze with integral collars in full compliance with AWWA. OS&Y (rising stems) shall be bronze. All stems shall operate with bronze stem nuts independent of wedge and of stem (in NRS valves). Stainless stems are available but not standard. NRS stems shall have two 0-rings located above thrust collar and one 0-ring below. Stem 0-rings shall be replaceable with valve fully opened and subjected to full pressure. The NRS stems on 2"-12" shall also have two low torque thrust bearings located above and below the stem collar to reduce friction during operation. Waterway shall be smooth, unobstructed and free of all pockets, cavities and depressions in the seat area. Tapping valves 4" and larger shall accept a full size tapping cutter. The body, bonnet, and 0-ring plate shall be fusion-bond epoxy coated, both interior and exterior on body and bonnet. Epoxy coating shall be NSF 61 certified and applied in accor- dance with AWWA C550. Each valve shall have manufacturers name, pressure rating, and year in which it was manu- factured cast in the body. Prior to shipment from the factory, each valve shall be tested by hydrostatic pressure equal to the requirements of AWWA C-509 (and UL/FM where applicable). Valves shall have all component parts cast and assembled in the USA and shall be manufactured by the Kennedy Valve Company. (Revised 03-272011) Lii.iiu II*. lit. I f1ii DELRIN THRUST BEARINGS ABOVE AND BELOW THE THRUST COLLAR REDUCE FRICTION AND MINIMIZE OPERATING TORQUES LONG, TROUBLE FREE LIFE WITH HIGH STRENGTH, NON-CORRO- SIVE BRONZE STEM AND STEM NUT. ALL NRS STYLE VALVES ARE STAIN- LESS THE OPERATING MECHANISM IS TRIPLE 0-RING SEALED TO COMPLETELY SEAL AGAINST LEAKAGE PAST THE STEM. TWO 0-RINGS ARE PROVIDED ABOVE THE THRUST COLLAR AND ONE BELOW. UPPER 0-RINGS CAN BE REPLACED UNDER PRESSURE WITHOUT REMOVING THE STEM WHEN THE VALVE IS FULLY OPENED. 0-RING SEALS AT STUFFING BOX AND BONNET TO BODY FLANGES TO ENSURE THE BEST POSSIBLE SEAL. NO FLAT GASKETS. 100% EPDM COATED WEDGE WITH TWIN SEAL DESIGN ENSURES BUBBLE- TIGHT SEAL UP TO 250 PSI EVERY TIME. ELLIPTICAL BOLT HOLE DESIGN ELIMINATES THE NEED FOR ANTI-ROTATION BOLTS KENNEDY CORROSION RESISTANT FUSION- BONDED EPDXY COATING, CONFORMING TO AWWA C-550 AND NSF61 CERTIFIED, PROTECTS BOTH INSIDE AND OUTSIDE OF VALVE. SMOOTH, UNOBSTRUCTED PADS ON THE BOTTOM OF FULL SIZE WATERWAY IS ALL VALVES KEEP VALVE FREE OF POCKETS, CAVI- IN UPRIGHT POSITION TIES, AND DEPRESSIONS FOR EASIER STORAGE ALLOWING FOR MINIMAL AND PROTECTION FROM FLOW LOSS AND LOWER THE ELEMENTS. PUMPING COSTS. ALL TAPPING VALVES ACCEPT FULL SIZE TAPPING CUTTER. ALL VALVES ARE RATED AT 250 PSI FOR AWWA SERVICE AND 200 PSI FOR ULFM SERVICE. ALL VALVES ARE HYDROSTATICALLY TESTED TO 500 PSI. 10 YEAR LIMITED WARRANTY (Revised 03-27-2011) 6E E 8571 8561 8057 8572 MECHANICAL JOINT ENDS FLANGED ENDS THREADED ENDS FLANGED X MJ 20. 12" 2 • 120 2"' 30 3'.12" Er 8597 8576 8901 8701 PUSH-ON FOR PVC MECHANICAL TYTON ENDS FLANGED ENDS 2" • 8" CUTTING-IN JOINT PUSH-ON FOR (DI. & 0900) POST INDICATOR VALVE (PIV) •-_____ 4"- 12' 4"-12" 3.12" F Ir E E fOPEN) 8902 8950 8071 8068 FLANGED & TYTON JOINT TAPPING X MJ MECHANICAL JOINT FLANGED ENDS PUSH-ON FOR (DI. & 0900) TAPPING VALVE POST INDICATOR VALVE (PIV) OS&Y CONSTRUCTION 4" • 12" 4' • 12" 3" • 12" 2112" • 12" A S C D E G H P Q R S U V No ot Turns toFU 2' 7 31/4 - 5 1/4 107/8 - - 3 - - 71/4 - - 43/4 21/2' 7 1/2 - - 7 11 3/8 - - 31/4 163/8 13 7/8 71/4 - - 51/2 3 8 3 1/2 - 7 1/8 123/8 - 5 3/4 3 1/2 18 7/8 15 5/8 10 - - 10 4 9 41/2 63/4 - 143/4 41/2 6 3/4 4 1/2 223/4 18 1/4 10 63/4 93/4 13 1/2 6' 101/2 5 77/8 - 19 51/4 7 3/4 5 301/8 23 3/4 12 75/8 11 3/16 191/2 8' 111/2 51/2 81/2 - 221/2 5 5/8 8 1/2 51/2 373/4 29 1/4 14 81/2 113/4 251/2 10' 13 7 1 10 - 1 261/2 1 7 1 10 - 453/4 1 353/8 18 10 1 131/2 311/2 12' 14 63/4 1 111/4 - 30 1 81/2 1 107/8 - 531/8 1 405/8 18 11 1 143/4 1 373/4 KENNEDY VALVE A DIVISION OF MCWANE, INC. www.kennodyvalve.com 2007 1021 E. Water Street Elmira, New York 14901 P.O. Box 981 Phone (607) 734-2211 Fax 1-607-734-3288 (Revised 03-27-2011) MJ Accessories ANSI/AWWA C111/A21.11 øD____ B1 ;I - - F I 28' for sizes 3-24 in. 20 for sizes 30-60 in NOM. SIZE PIPE A O.D.±19' B C OD E F G 2 2.50 0.48 0.62 0.31 2.48 0.12 0.15 1.05 3 396 048 062 031 386 012 015 105 4 4.80 0.62 0.75 0.31 4.68 0.16 0.22 1.22 6 690 062 075 031 673 016 022 122 0.16 8 9.05 0.62 0.75 0.31 8.85 0.22 1.22 10 1110 062 075 031 1087 016 022 122 12 13.20 0.62 0.75 0.31 12.95 0.16 0.22 1.22 14 15.30 0.62 0.75 0.31 14.99 0.16 0,22 1.22 --- 16 17.40 0.62 0.75 0.31 17.07 0.16 0.22 1.22 18 19.50 0.62 0.75 0.31 19.13 0.16 0.22 1.22 20 21.60 0.62 0.75 0.31 21.20 0.16 0.22 1.22 24 25.80 0.62 0.75 0.31 25.34 0.16 0.22 1.22 0.73 1.00 30 32.00 0.38 31.47 0.16 0.37 1.54 36 38.30 0.73 1.00 0.38 37.67 0.16 0.37 1.54 0.73 1.00 42 44.50 0.38 43.78 0.16 0.37 1.54 48 50.80 0.73 1.00 0.38 49.98 0,16 0.37 1.54 N' 0111- ~No ________ 11 % r 7 Bf UCAT. 14.01 REGISTERED TRADEMARK OP STAR PIPE PRODUCTS STAR7 PIPE PRODUCTS FM HOUSTON CORPORATE TOI.I. FREE I80099931)9 FAX 281SS89000 plppoducR.com Page 17 MJ Accessories ANSI/AWWA C111/A21.11 1-Bolts, Double Ended Rods & Nuts HSLA STEEL SPECIFICATIONS: Bolts & Nuts are manufactured in accordance with ANSI I AWWA C1 11 / A21.1 1 Material is High Strength Low Alloy Steel per ANSI/AWWA C1 11 /A21.1 1 Threads per ASME B 1.1 unified standard coarse (Class 2A & 2B) MECHANICAL PROPERTIES Yield Strength 45000 PSI (mm) Elongation in 2in. 20% (mm) BLUE BOLT/NUT/ROD CHEMICAL PROPERTIES Carbon 0.20% Max Manganese 1.25% Max Sulfur 0.05% Max Nickel 0.25% Mm Copper 0.20% Mm Combined 1.25% Mm (Ni, Cu, Cr) T-Bolts, Rods & Nuts have fluoropolymer coating material which is VOC-compliant, resin-bonded, thermally cured and dry lubricant. COATING PHYSICAL PROPERTIES Film Thickness: 0.3 to 0.4 mil per coat Number of Coats: 3 to 4 coats Adhesion: 1 mm cross hatch test + 5 Pulls. Good knife resistance Cure Test: 50+Rubs with MEK. No substrate exposure Pencil Hardness: Pencil Hardness: 4-6H Volatile Organic Compounds 2.741b5/gal Stainless Steel 1-Bolts & Nuts ALLOYS SS 304 & SS 316 PER ASTM F593 SPECIFICATIONS: 1-bolt dimensions are manufactured in accordance with ANSI / AWWA C1 11 / A21.1 1. 1-bolt alloys SS 304 and SS 316 per ASTM F593 Heavy Hex Nut Alloys SS 304 & SS 316 per ASTM F594. MECHANICAL PROPERTIES Tensile Strength: 85,000 PSI to 140,000 PSI Yield Strength: 45,000 PSI (mm) COATING SPECIFICATION Nuts have fluoropolymer coating material which is VOC-Compliant, resin-bonded, thermally cured and dry lubricant. COATING PHYSICAL PROPERTIES Film Thickness: 0.3 to 0.4 mil per coat • Pencil Hardness: 4-6H Number of Coats: 3 to 4 coats • Volatile Organic Compounds 2.74 lbs/gal Adhesion: 1mm cross hatch test + 5 Tape Pulls. • Continous use temperature - 356°F Cure Test: 50+ Rubs with MEK, no substrate exposure • Color: SS 304 is green. SS 316 is red A. AWWA MEMBER UCAT.I4.OI REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTSHOUSTON CORPORATE ITOLL FREE 1-800-999-3009 F4)I 291-558-9000 pippducRIom Page 18 I,isI:stIW0I PIPE SIZE (IN) 1BOLTTORQUE BOLT SIZE RANGE' OF (IN) TORQUE (Ft-EBS) 2-3 5/8 45-60 4-24 3/4 75-90 30-36 1 100-120 42-48 11/4 120-150 'These torque ranges are requirements ofAWWA C600 Accessories ANSI/AWWA C111/A21.11 1/8-in. Radius Maximm FFZ r- B '-. R B/2 c ,j Minimum 1/16-in x 45Chamfer. k__ - - - ANN :Riiu.i (LOW vALLOY i iEL) BOLT &ttsi NOM A B C D THREADS F H R SIZE PER IN. %x3 1.50 0.625 3.00 2.00 11 0.625 1.062 0.625 0.312 ,5x3½ 150 0625 350 270 11 0625 1.062 0.625 0312 1/4x3 1/2 1.75 0.750 3.50 2.50 10 0.750 1.250 0.750 0.375 1/4x4 1.75 0.730 4.00 3.00 10 0.750 1.250 0.750 0.375 1/4x4½ 1.75 0.750 4.50 3.00 10 0.750 1.250 0.750 0.375 3/4X5 1.75 0.750 5.00 3.00 10 0.750 1.250 0.750 0.375 '/4x5 ½ 1.75 0.750 5.50 3.70 10 0.750 1.250 0.750 0.375 2.25 1.000 530 3.00 8 1.000 1.625 1.000 0.500 1x6 2.25 1.000 6.00 3.00 8 1.000 1.625 1.000 0.500 1 ¼x6 230 - 1.250 6.00 6.50 3.00 3.50 7 7 1.250 1.250 2.000 2.000 1250 1.250 0.625 0.625 1¼x6½ 2.50 1.250 1¼x8½ 250 1250 830 350 I 7 1250 2000 1250 062 A--4---- 1 Radius !III '- R Minimum 1/16-ins 45Chamfee. 8/2 ANNE ANTI-ROTATIONANTI-ROTATION i!(LOW ALLOY4STEEL) J1LSThU itsi NOM. A SIZE B C I) E THREADS PER IN. F H R SA .3 130 0.625 3.00 2.00 0.63 11 0.625 1.062 0.625 0.312 ~x3½ 150 0.625 350 230 063 11 0.625 1.062 0.625 0312 1.250 Nx3½ 1.75 0.750 3.50 230 0.63 10 0.750 0.750 0.375 ~x4 1.75 0.750 4.00 3.00 0.63 0.750 1.250 0.750 0375 10 0.375 ~x4½ 1.75 0.750 4.50 3.00 0.63 10 0.750 1.250 0.750 4xS 1,75 0.750 5.00 3.00 0.63 10 0.750 1.250 0.750 0.375 Page 19 'REGISTERED TRADEMARK OF STAR PIPE PRODUCTS START PIPE PRODUCTS HOUSTON CORPORATE TOLL FREE l.8OO.999.3C9 FAX 2RI.55S.9CO NOM. T A SIZE 11 WT (LBS.) A R WT (LBS.) A R WT (LBS.) A R WT (LBS.) 2 0.39 3.25 2.25 14 1.80 1.96 13 1.80 4.02 13 1.80 8.12 13 3 048 550 400 35 300 362 30 300 756 30 300 1525 30 4 0.52 6.50 4.50 55 4.00 4.81 so 4.00 10.06 so 4.00 2031 50 6 055 800 - 600 85 500 725 75 500 1506 75 300 3050 75 0.60 9.00 7.00 125 8 5.50 8.44 110 5.50 17.62 110 5.50 35.50 110 10 0.68 11.00 9.00 190 6.50 10.88 155 6.SO 22.62 160 6.50 45.69 160 12 0.75 12.00 10.00 255 7.50 13.25 215 7.50 27.62 220 7.50 55.81 220 14 0.66 14.00 11.50 340 7.50 12.06 270 7.50 25.12 275 7.50 50.75 _275- 16 0.70 15.00 12.50 430 8.00 13.25 340 8.00 27.62 345 . 8.00 55.81 345 18 0.75 16.50 14.00 545 8.50 14.50 420 8.50 30.19 430 8.50 60.94 430 20 0.80 18.00 15.50 680 9.50 16.88 1882 530 755 9.50 1100 35.19 535 3769 765 9.50 1100 71.06 7612 540 770 24 089 2200 1850 1025 1100 30 1.03 25.00 21.50 1690 15.00 27.75 1380 15.00 57.81 1400 15.00 116.75 1410 36 1.15 28.00 24.50 2475 18.00 35.00 2095 18.00 72.88 2135 18.00 147.25 2145 3035 42 1.28 31.00 27.50 3410 21.00 42.25 2955 21.00 88.00 3020 21.00 177.69 48 1.42 34.00 30.50 4595 24.00 49.50 4080 24.00 103.06 4170 24.00 208.12 4190 rMjfl11)lI1i NOM. T SIZE A B I R WT (LBS.) A I B R WT' (LBS.) A' B 'WT1 (LBS.) A B R 'WT (LBS.) 3 0.48 5.50 13.50 4.00 35 3.00 11.00 3.62 30 3.00 11.00 7.56 30 3.00 11.00 15.25 30 4 0.52 650 1450 4.50 50 4.00 12.00 4.81 45 4.00 12.00 10.06 45 4.00 12.00 2031 45 6 0.55 800 1600 6.00 80 500 13.00 7.25 70 5.00 1300 15.06 70 5.00 1300 300 70 8 060 9.00 1700 7.00 120 550 13.50 8.44 105 5.90 13.50 1762 105 5,50 13.50 3550 105 10 0.68 11.00 1900 9.00 190 650 14.50 10.88 155 6.50 14.50 22.62 160 6.50 14.50 45.69 160 12 0.75 1200 20.00 1000 235 790 15.50 13.25 215 7.50 1590 27.67 220 7.50 15.$0 55.81 220 14 066 1400 2200 11.50 325 750 15.50 12.06 255 7.50 15.50 2912 260 7.50 15.50 50.75 260 16 0.70 1500 23.00 1250 410 800 1600 13.25 320 800 1600 27.62 325 8.00 16.00 55.81 325 985 24 089 2200 3000 18.50 1100 19.00 18.12 715 11.00 19.00 3769 725 11.00 19.00 76.12 730 30 , 1.03 2500 3300 21.50 1585 1500 23.00 27.75 1275 15T623.00 9781 1295 15.00 23.00 116.75 1305 36 1.15 28.00 36.00 24.50 2310 18.00 26.00 35.00 1930 18.00 26.00 72.88 1970 18.00 26.00 147.25 1980 1 42 1.28 31.00 3_9_.0.0__',.'2'_7_50''.,_3200_.. 21.00 29.00 42.25 2745 21.00 29.00 88.00 2810 1 21.00 29.00 177.69 2825 UCAT.I4.Ot REGISTERED TRADEMARK OF STAR PIPE PRODUCTS STAR PIPE PRODUCTS HOUSTON CORPORATE ITOI.L FREE I.IOO.999.39 P4XZSI.SSS.SEEO 311 Page 22 1 AX. [7, GUARDIAN I IqffyJ) FIRE EQUIPMENT, INC. DETAIL AND SUBMITTAL SHEET MIAMI, FL Ph. 800.327.6584• Fax 800.827.3869 6300 Series Fire D ept.i1 rn flt.ii'i.ii Bodies Project/Location: Date: Architect/Engineer: Qty: Contractor: IAppropriate Selection Used as auxiliary connections through which the fire department can pump water to supplement existing water supplies. Provides 250 GPM flow (minimum), per 21/2" inlet. Two and three-way - inlet connections feature clappered brass bodies (straight or angle pattern), with female hose thread swivel inlets and female outlets. Cast brass construction, standard. Model No. 6314* Outlet Back Size 4" x 21/2 x 21/2' Clappers 1 A 51/2" _ B 81/8" 6315* Angle 4" x 21/2" x 21/2 1 81/8" 53/4 El 6324 Back 4"x 21/2" x 21/2" 2 71/4" 101/2 6325 Angle 4" x 21/2" x 21/2" 2 81/4" 102" i:i 6326 Back 6" x 21/2" x 21/2" 2 71/4"102" 6327 Angle 6" x 21/2" x 21/2" 2 10" 101/2" E] 6336 Back 6" x 21/2" x 21/2'x 21/2" 3 101/2 13I4" E 6337 Angle 11 6" x 21/2" x 21/2" x 21h" 3 111/2" 141/2" Body Lettering 0 AUTO SPKR 0 STANDPIPE 0 Blank (unlettered) "Auto Spkr lettering only Optional Finish:[] -13 Polished Brass Threads: -C Rough Chrome Plated 0 NST E] -D Polished Chrome Plated 0 Other Plugs with Chains and Break Caps - Used to keep fire dept. inlet connections free of debris and protect female threads. Break Caps f ç\ ____ 0 6406 1'Aluminum 0 6407 I2'/2"j Plastic Threads: Adjustable Plugs NST ____ DOther 0 6408 21/2" Aluminum 0 6409 21/2" Plastic Ii' Plugs with Chains IIVIUUI rio. izo I uype Optional Finish: 0-B Polished -C Rough Chrome Plated -D Polished Chrome Plated Contact factory for current listings and approvals I - I