Loading...
HomeMy WebLinkAbout1890 RUTHERFORD RD; ; FA040029; Permit10/27/21, 10:19 AM FA040029 Permit Data City of Carlsbad Fire Alarm Permit 1890 RUTHERFORD Job Address: RD Permit Type: FALARM Parcel No: 2121203500 Lot #: 0 Permit No: FA040029 Status: ISSUED Applied 1/26/2004 Approved: 2/3/2004 Reference No.: Issued: 2/3/2004 PC #: Inspector: Project Title: ISIS SCIF ROOM FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: CONSTRUCTION ELECTRONICS 13715 STOWE DR POWAY, CA (858) 513-0200 Owner: PDG CARLSBAD 47&48 L P 4330 LA JOLLA VILLAGE DR #110 SAN DIEGO CA —''90 ($) L Fees .L f 1/1 FIRE ALARM 1890 Rutheford Rd. Carlsbad, CA 92008' Associated PFN: CB033544 Equipment Submittal Prepared by: Construction Electronics, Inc. 13715 Stowe Drive Poway, CA 92064 Phone: 858 513-0200 FAX: 858 513-1222 January 23, 2004 W [1 . 0 ISIS I SCIF #143 S FIRE ALARM 1890 Rutheford Rd. Carlsbad, CA 92008 Fire Alarm Equipment List Device Manufacturer Part Number CFM Listing Photoelectric Smoke Detector Notifier FSP-751 7272-0028:206 with Compatibility Chart Audible Strobe **CD Wheelock AS2430-C-FW 7125-0785:131 Wire, FPLP Atlas 1761**12J 1761-0972:100 S S S ) GENERAL The NOTIFIER FSP-751 (photo) and FSI-751 (ion) are ana- log, addressable, low-profile (height measures only 1.66"! 42.164 mm) smoke detectors designed for the entire line of intelligent systems from NOTIFIER. The FSP-7511 photo model includes a built-in thermal (heat) detection device. If either condition (smoke or heat) is detected, the device will alarm. The addressability of the FSP-751 and FSl-751 enables the control panel to provide firefighters with a pinpoint descrip- tion of where the fire is located. The FSP-751 and FSl-751 are also analog devices. The control panel is capable Of not only knowing the detector's location but exactly how much smoke is in the chamber of the detector. The detector may be set for different sensitivity settings appropriate to the en- vironment of its location. Analog devices continually send obscuration values to the con- trol panel. These values may be gathered so as to allow the control panel to determine if a detector has accumulated an excessive amount of dirt or dust A "maintenance" required indication allows the installer to clean the smoke detector be- fore an unwanted false alarm occurs. The FSI-751 Intelligent Ionization Sensor incorporates a unique single-source chamber design to respond quickly and dependably to a broad range of fires. The FSP-751 Intelligent Photoelectric Sensor's unique opti- cal sensing chamber is designed with superior signal to noise ratio. The optical chamber is engineered to sense the pres- ence of smoke produced by a wide range of combustion sources. FlashScan® (patent pending) is a new communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelli- gent devices and certain NOTIFIER systems. Intelligent de- vices communicate in a grouped fashion. If one of the de- vices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. FlashScan® is a registered trademark of NOTIFIER. FEATURES - Sleek, low-profile design (height only 1.66742.164 mm). Common base for both photo and ion detectors. - Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Rotary 01 to 159 address switches (01 to 99 on traditional systems). - Optional remote, single-gang LED accessory (RA400Z). Dual LED design provides 360° viewing angle. December 15, 2000 DN-6714• H-200 FSI-751 and FSP-751/751T Low-Profile Intelligent Plug-in Smoke Detectors with FlashScan® Section: Intelligent/Addressable Devices LISTED CS308 SillS MARYLAND State Fire Marshal < > 2020 (FSI-751) 2013 (FSP-7511-751T,) Approved 6714ph01jp9 FSP-751T with B7IOLP base FSP-751 with RMK400 recessed mounting kit Visible bicolor LEDs blink green every time the detector is addressed, and illuminate steady red on alarm. Walk test with address display (an address of 121 will blink the detector LED: 12-(pause)-1) (FlashScan(D systems only). Built-in functional test switch activated by external mag- net. Optional relay, isolator, or sounder bases. Listed to UL 268. SPECIFICATIONS Size: 1.66" (42.16 mm) high x4.1" (104.14 mm) diameter. Shipping weight: 3.6 oz. (104 g). Operating temperature: 0°C to 49°C (32°F to 120°F). j ) California State Fire Marshal 7272-0028:206 (FSP-751/-751T) 7271-0028:201 (FSI-751) MEA 277-99-E (FSP-751, -751 T only) This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS0900 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 .. i NOTIFIER 12 Clintonville Road, Northford, Connecticut 06472 ENGINEERING &MANUFACTI1RIN DN-6714 . 12/15/00 - Page 1 of 4 UL listed velocity range: ION: 0 - 1500 fpm (0 - 7.62 m/ sec). PHOTO: 0 - 4000 fpm (0 - 20.32 mlsec). Relative humidity: 10% - 93% noncondensing. ELECTRICAL SPECIFICATIONS: Voltage range: 15 -32 volts DC peak. Standby current - ION: 200 pA @ 24 VDC (without com- munication); 300 pA @ 24 VDC (one communication every 5 seconds with LED enabled). Standby current - PHOTO: 250 pA @ 24 VDC (without communication); 360 pA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @ 24 VDC (ON"). Air velocity ratings: FSP-751 & FSP-751T to 4,000 ft./min. (1219.2 rn/mm.). FSI-751: to 1,500 ft./min. (457.2 rn/mm.). BASES AVAILABLE: B71OLP: 6.1" (154.94 mm) diameter. B501: 4.1" (104.14 mm) diameter. B50IBH or B50IBHT: Sounder base assembly. Includes B501 base. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm'). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A@ 30 VDC in- ductive. Dimensions: 6.2" (157.48 mm) x 1.2" (30.48 mm). B524B1 Isolator Base: Dimensions: 6.2" (157.48 mm) x 1.2" (30.48 mm). Maximum: 25 devices between isolator bases. Duct applications: FSP-751 and FSP-751T are Listed for use in air ducts. See Duct Application Guide A05-1004 for details on pendant-mount applications. NOTE: These prod- ucts are NOT Listed for use inside a duct smoke detector housing. INSTALLATION The FSP-751 and FSI-751 plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and re- move detectors without using a ladder. Mount base on a box which is at least 1.5" (38.1 mm) deep. Suitable mounting base boxes include: 4" (101.6 mm) square box. 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box. Single-gang box (except relay or isolator base). With B50IBH base, use a 4" (101.6 mm) square box. With B224RB or B224B1 base, use a 3-112" (88.9 mm) octagonal box, or a 4" (101.6 mm) octagonal or square box. SMOKE GUARD Cover:' 16 gauge perforated steel (3/16" [4.7625 mm] dia. perforations on 1/4" [6.35 mm] staggered centers). 51% open. SDG-773 is 3" (76.2 mm) deep by 7" (177.8 mm) wide. Frame: 3/4" x 3/4" (19.05 x 19.05 mm) angle, 14 gauge solid steel. All guards are supplied with the following: 11 Guards fasten to mounting frame with No. 10/24 x 3/8' (9.525 mm) long Allen-head screws (10/24 spanner-he screws and tool option at extra cost). - 2) Standard finish: Cool Tan" baked enamel. MOUNTING DIAGRAM SDG-773 Smoke Guard 4762dgn Page 2 014 - DN-6714.12/15/00 PRODUCT LINE INFORMATION Model Description FSl-751 Low-profile intelligent ionization sensor. Must be mounted to one of the bases listed below. FSP-751 Low-profile intelligent photoelectronic sensor. Must be mounted to one of the bases listed be- low. FSP-751T Same as FSP-751 but includes a built-in 135°F (57°C) fixed-temperature thermal device. BASES: B7IOLPBP Standard U.S. low-profile base, pkg. of 10. B501 BP Standard European flangeless base, pkg. of 10. B50IBH Sounder base, includes B501 base above. B501 BHT Same as 8501 BH, but includes temporal sounder. B224RB Intelligent relay base. B224Bl Intelligent isolator base, Isolates SLC from loop shorts. ACCESSORIES: SDG-773 Smoke Detector Guard. This guard is mechani- cally compatible with both FSI-751 and FSP-751 detectors. It is UL-compatibility listed with the FSP-751 (file UL S5515). Itis NOT UL-compat- ibiity listed with the FSI-751. FIIO Retrofit replacement flange for BX-501 base. Converts BX-501 base for use with FlashScan detectors. RA400Z* Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. SMK400 Surface mounting kit provides for entry of sur- face wiring conduit. For use with B501 base only. RMK400 Recessed mounting kit. For use with B501 base only. SMB600 Surface mounting kit for use with B7IOLP. M02-04-01 Test magnet. M02-09-00 Test magnet with telescope stick. XR-2 Detector removal tool. Allows installation and/ or removal of FlashScan Series detector heads from base in high ceiling installations. XP-4 Extension pole for XR-2. Comes in three five- foot sections. *Supported by B7IOLP and B501 bases only. OPTIONAL SDG-773 Smoke Guard (1.905 cm) 7" (17.78 cm) 3/4 Ceding Or Wall MODEL NO. SDG-773 ad 3" (7.62 cm): r.wmf ) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE 5 LISTING No. 7272-0028:206 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models FSP-751, HPX-751, FSP-751T, *FSH..751*(1)FApT..751 *FApT851 *FSp..851 and *FSp..851T photoelectric type smoke detectors. Models FSP-751T and *FSP..8511 employ a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. *Models FSP-751, FSP-751T, *FApT..751 *FApT..851 *FSP.. 851 and *FSP..851T Models FSP-751 and FSP-751T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with S air velocities between 0-300 fpm. *Model FSH-751 is suitable for open areas with air velocity between 0-400 fpm. NOTE: 1. Combined with 7272-0028:208 2. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 07 -24-2002 B This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or i recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation lk...._JJ criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 8, 2003 Listing Expires June 30, 2004 5 Authorized By: DIANE K. AREND, Senior Deputy Program Manager S - ION= i : : cI•.L.AJ I 131. 77 . FIRE ALARM SYSTEMS i' i V- 1 r rrt S. I .Fniy tf pflt& Description Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 15/75cd or Wheelock's patented Multi-Candela strobe with field selectable candela settings of: 15, 30, 75 or 110cd. SERIES AS SERIES AH SERIES AS SINGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCES SERIES AH AUDIBLES S.) S Ceiling mount models are available in 15, 30, 75 Or 100cd intensities. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. Additionally, the audible may be silenced while maintaining strobe activation. All models may be synchronized when used in conjunction with the Wheeldck SM, DSM Sync Modules or the PS-12/24-8 Power Supply with Wheelock's Patented Sync Protocol. Synchronization of the continuous horn tone provides the temporal (Code 3) tone as mandated by NFPA-72 for all audible appliances. This ensures a distinct temporal (Code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized, the temporal sound may overlap and not be distinctive. At the same time, the strobes will also be synchronized. This provides the ability to comply with ADA recommendations concerning photosensitive epilepsy and NFPA and UFC standards when installing two or more visual appliances within the field of view. All of this, plus the ability to silence the audible is achieved by using only 2 WIRES. For Weatherproof Series AS, See Datasheet S9004 Copyright 2003 Wheelock Inc. All rights reserved. Multi-Candela Indicator (bottom of lens) Features Approvals include: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), New Yorl< City (MEA), and Factory Mutual (FM) Pending: Chicago (BFP). ADA/NFPA/UFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15, 30, 75 or 1 10c (Multi-Candela models) or 15175cd. Weatherproof wall mount UL Listed for outdoor use (ASWP) Ceiling mount models are available in 15, 30, 75 or 100cd. Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones. Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate. Strobes produce 1 flash per second over the regulated voltage range. 12 and 24 VDC models with wide UL 'Regulated Voltage" using filtered DC or unfiltered VRMS input voltage. Wall Mount or Ceiling Mount models. Synchronize with Wheelock SM, DSM or PS-12/24-8 Power Supply with Wheelock's built-in sync protocol. Compatible with all Wheelock 2-Wire products. Fast installation with IN I OUT screw terminals using #12 to #18 AWG wires. Table 1: Ratings Per UL 1971 Model Input Voltage VDC Regulated ,9Re Range VDC1F Strobe Candela (Cd) As-24Mcw-FR 24 16.0-33.0 16/30/75/110 AS-241575W-FR 24 16.0-33.0 15 (75 on AXIS) AS-121575W-FR 12 8.0-17.5 15 (75 on Axis) AS-2415C-FW 24 16.0-33.0 15 As-2430c-Fw 24 16.0-33.0 30 As-2475C-FW 24 16.0-33.0 75 AS-24100C-FW 24 16.0-33.0 100 ASWP-2475W-FR 24 16.0-33.0 76 @ -31F Table 2: Awrage Crai (AJhSI forAS-24 MC VIltil Models @ Each Candela Selling Avenge Cunmwith Hi dBA 560mg (99 cE.4) Voltage 15od 30cd 75od 110i iSO VtC J .095 .142 242 308 24.0 VEt - .008 .120 .174 224 3a0 VEt .099 .120 .152 .190 Avenge Curmiwtfti Medium dBA Selling (95 cEA.) 16.0 VDC .081 .128 .215 .208 24.0 VDC .068 .105 .157 207 30VtC .068 1 .090 .119 .157 Average Cuninlntth Low dBA Setting (90 cEA.) 150 VDC .077 .119 294 24.0 VDC .008 .090 .142 .290 33.0 VDC .055 381 .109 .147 Table 3: Average Current * (AMPS) Series AH-24-R/W & AH-12-R/W & WP (Horn only) VOLTAGE High Medium Low 16.0 VDC .033 .019 .013 24.0 VDC .047 .025 .016 33.0 VDC .066 .033 .020 8.0 VDC .089 .035 .029 12.0 VDC .103 .047 .033 17.5 VDC .122 .066 .040 • S Table 4: Average Currant * (AMPS) Series AS-241575 VOLTAGE High Medium Low 16.0 VDC .124 .108 .103 24.0 VDC .102 .083 .077 33.0 VDC .100 .077 .067 Table 5: dBA Ratings for 12 VDC and 24 VDC Series AS/AH 12 and 24 VDC Audible Description Volume Reverberant dBA Per UL 464 © 10 ft. Anechoic dBA t( loft. Continuous Horn High 91 99 Medium 88 95 Low 83 90 Code 3 Horn High 87 99 Medium 84 95 Low 79 90 Table 6: Average Current - (AMPS) for Ceiling Mount 24 V Audible Strobe At the 3 Audible Settings © 16, 24, and 33 VDC dBA Levels Models Voltage 16.0 VDC 24.0 VDC 33.0 VDC Average Current With High dBA Setting (99 dBA) AS-2415C .130 .106 .102 AS-2430C .178 .135 .131 AS-2475C .357 .248 .200 AS-241000 .404 .277 .245 Average Current with Medium dBA Setting (95 dBA) AS-2415C .116 .091- .079 AS-2430C .164 120 .103 AS-2475C .339 .226 .179 AS-24100C .389 .217 Average Current with Low dBA Setting (90 dBA) AS-2415C .112 .082 .069 AS-2430C .160 .113 .095 AS-2475C .332 .219 .164 AS-24100C .382 .252 .207 Table 7; Average Current (AMPS) for Wall 15/75 od IZVAudible Strobe At the 3 Audible Settings 58, 12, & 17.5 [Voltage dBA Level I Model - EA VDC - 12.8 VDC - 17.5 VDC Averge Current with High dBA AS.I2I575W .408 .206 .251 (99 dBA) Average Current with Medium AS-121575W .354 .207 .182 dBA ISO dBA) Average Current with Low cIBA J AS121S75W I .349 .194 .162 (95 dBA) NOTE: All CAUTIONS and WARNINGS are identified by the symbol All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS C A R E F U L L Y B E F O R E USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, C A U T I O N S O R W A R N I N G S C O U L D R E S U L T I N I M P R O P E R APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATI O N , W H I C H C O U L D R E S U L T I N P R O P E R T Y DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Genera! Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of I to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series AS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range o f 3 2 ° F t o 1 2 0 ° F ( 0 ° C t o 4 9 ° C ) a n d maximum humidity of 93% (± 2%). Series AH-24 horns are listed under UL Standard 464 for audible signal appliances (Indoor u s e o n l y ) . Series AH-24WP audible appliances are listed under UL Standard 464 for indoor/outdoor use with a t e m p e r a t u r e r a n g e o f - 3 1 ° F t o 1 5 0 ° F (-35°C to 66°C) and maximum humidity of 95%. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "listed Voltage Range". SYNC MODULES I POWER SUPPLY Inpral Amrego Model Number Order Voltage Current Mounting Code (VDC) (AMPS)5 Opltons 24 VDC SM.12124.R 6369 24 .028 W 05M-12/24-R 6374 24 .035 W PS..12I24.t 8114 120 VAC - #SM Sync Module is rated for 3.0 amperes @ 24 VDC. ##DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. 8Refer to Data Sheet S9001 or Installation Instructions P83862 for PS- 12124-8 Power Supply. C Average Current per actual Wheelock Production Testing at listed VDC. For Rated Average and Peak current across UL Regulated Voltage Range for both Filtered DC and Unfiltered VRMS, see Installation Instructions. Refer to Data Sheet S7000 for Mounting Options. ) . A. WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION I N S T R U C T I O N S " ( P 8 3 9 4 7 ) S E R I E S A S . 2 4 M C W , ( P 8 4 0 2 3 A N D P 8 4 0 2 4 ) S E R I E S AS SINGLE CANDELA, (P83519).Seies AN, (P83641) Series AH-WP AND " G E N E R A L I N F O R M A T I O N " S H E E T ( P 8 2 3 8 0 ) O N T H E S E P R O D U C T S . T H ESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT TH A T Y O U H A V E C U R R E N T I N F O R M A T I O N O N T H E S E P R O D U C T S . T H E S E M A T E R I A L S CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRI O R T O S P E C I F Y I N G O R I N S T A L L I N G T H E S E P R O D U C T S , I N C L U D I N G : TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO S Y S T E M S E C O N D A R Y P O W E R S O U R C E S . FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO H A N D L E P E A K C U R R E N T S F R O M A L L A P P L I A N C E S O N T H O S E C I R C U I T S . ADDING REPLACING OR CHANGING APPLIANCES OR CHANGING CAN D E L A S E T T I N G S W I L L E F F E C T C U R R E N T D R A W . R E C A L C U L A T E C U R R E N T DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL P E A K R E Q U I R E D B Y A L L A P P L I A N C E S D O N O T E X C E E D T H E R A T E D CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES wrrH!N A PERSON'S FIELD OF VIEW. THE VOLTAGE APPUED TO THESE PRODUCTS MUST BE WITHIN T H E I R " R E G U L A T E D V O L T A G E R A N G E " . INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPIN G A R E A S . INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION A N D I N S T A L L A T I O N I S S U E S . THESE APPUANCES ARE NOT DESIGNED TO BE USED ON CODED SYS T E M S I N W H I C H T H E A P P L I E D V O L T A G E I S C Y C L E D O N A N D O F F . FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR G E N E R A L I N F O R M A T I O N S H E E T S C O U L D R E S U L T I N I M P R O P E R I N S T A L L A T I O N , APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EM E R G E N C Y S I T U A T I O N , W H I C H C O U L D R E S U L T I N P R O P E R T Y D A M A G E A N D SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACIFY SHOULD B E T A K E N I N T O C O N S I D E R A T I O N P R I O R T O D E S I G N A N D I N S T A L L A T I O N O F T H E S E PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. .) S Wiring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROM + TO NEXT APPLIANCE - OR EOLR OR FACP PRECEDING APPLIANCE SERIES AS APPLIANCES SYNCHRONIZED WI DSM MODULE CLASS"A" NAC CIRCUIT W/ NO AUDIBLE SILENCE FEATURE DSM STROBE NAC SYNC CIRCUIT 0 r FACP LL IN AS AS AS I 0- MINUSI L............ AUDIBLE MINUS 2 SAS STROBE e CIRCUIT RETURN SERIES AS APPLIANCES SYNCHRONIZED W/ SM MODULE S I N G L E CLASS "B" NAC CIRCUIT W/ AUDIBLESILENCE FEATURE STROBE - STROBE Strobe A NAC Circuit EOLR Audible -Audible NAC Circuit SERIES AS APPLIANCES SYNCHRONIZED W/ MULTIPLE DSM MODULES DSM #1 Sync Strobe NAC cir O,udible NAC Or I r iI.S AS F Audible NAC Cie .2 . Strobe NAC Cii Sync IASki FP j I1J'AS Audible NAC Ch OEM #3 P NELEIR D OEM Interconnecting wiring Shown. Maximum of twenty (20) SERIES AS & RSS APPLIANCES SYNCHRONIZED W/ PS-12-24-8 OUTPUTS 0010 1-4 4 ClASS A OR AS ns 201055 ne,io PS-12124.E In - I AS RW # For detail using SM or DSM Sync Module refer to Data Sheet S3 0 0 0 o r I n s t a l l a t i o n I n s t r u c t i o n s P 8 3 1 2 3 f o r S M a n d P 8 3 1 7 7 f o r D S M . For wiring information on the PS-12/24-8 Power Supply refer to Installation I n s t r u c t i o n s P 8 3 8 6 2 . Wheelock products must be used within their published specifications and m u s t b e P R O P E R L Y s p e c i f i e d , a p p l i e d , i n s t a l l e d , o p e r a t e d , m a i n t a i n e d and operationally tested in accordance with their installation instructions at t h e t i m e o f i n s t a l l a t i o n a n d a t l e a s t t w i c e a y e a r o r m o r e o f t e n a n d i n accordance with local, state and federal codes, regulations and laws. S p e c i f i c a t i o n , a p p l i c a t i o n , i n s t a l l a t i o n , o p e r a t i o n , m a i n t e n a n c e a n d t e s t i n g must be performed by qualified personnel for proper operation in acc o r d a n c e w i t h a l l o f t h e l a t e s t N a t i o n a l F i r e P r o t e c t i o n A s s o c i a t i o n ( N F P A ) , Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupatio n a l S a f e t y a n d H e a l t h A d m i n i s t r a t i o n ( O S H A ) , l o c a l , s t a t e , c o u n t y , province, district, federal and other applicable building and fire standards, guid e l i n e s , r e g u l a t i o n s , l a w s a n d c o d e s i n c l u d i n g , b u t n o t l i m i t e d t o , a l l appendices and amendments and the requirements of the local authority h i v i n g j u r i s d i c t i o n ( A H J ) . 0 Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS A u d i b l e S t r o b e a p p l i a n c e s a n d S e r i e s A N A u d i b l e a p p l i a n c e s o r approved equals. The Series AS Audible Strobe shall mee t a n d b e l i s t e d f o r U L S t a n d a r d 1 9 7 1 ( E m e r g e n c y D e v i c e s f o r t h e Hearing-Impaired) for Indoor Fire Protection Service. The S e r i e s A H A u d i b l e s h a l l b e U L L i s t e d u n d e r S t a n d a r d 4 6 4 ( F i r e Protective Signaling). The audible/strobe shall be listed f o r i n d o o r u s e a n d b o t h s h a l l m e e t t h e r e q u i r e m e n t s o f F C C P a r t 1 5 Class B. All inputs shall be compatible with standard rever s e p o l a r i t y s u p e r v i s i o n o f c i r c u i t w i r i n g b y a F i r e A l a r m C o n t r o l Panel (FACP). The audible portion of the appliance shall have a minimum of t h r e e ( 3 ) f i e l d s e l e c t a b l e s e t t i n g s f o r d E A l e v e l s a n d s h a l l h a v e a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flas h r a t e o f o n e ( 1 ) f l a s h p e r s e c o n d o v e r t h e R e g u l a t e d V o l t a g e R a n g e and shall incorporate a Xenon flashtube enclosed in a rugge d L e x a n ® l e n s . T h e S e r i e s A S s h a l l b e o f l o w c u r r e n t d e s i g n . Where wall mount, Multi-Candela appliances are specified , t h e s t r o b e i n t e n s i t y s h a l l h a v e a m i n i m u m o f f o u r ( 4 ) f i e l d s e l e c t - able settings and shall be rated per UL Standard 1971 f o r : 1 5 , 3 0 , 7 5 o r 1 1 0 c a n d e l a . T h e s e l e c t o r s w i t c h f o r s e l e c t i n g t h e candela shall be tamper resistant and not accessible from t h e f r o n t o f t h e a p p l i a n c e . T h e 1 5 / 7 5 c a n d e l a s t r o b e s h a l l b e specified when 15 candela UL Standard 1971 Listing with 75 c a n d e l a o n - a x i s i s r e q u i r e d ( e . g . A D A compliance). For ceiling mount applications, the strobe i n t e n s i t y s h a l l b e 1 5 , 3 0 , 7 5 o r 1 0 0 c a n d e l a . When synchronization is required, the appliance shall be com p a t i b l e w i t h W h e e l o c k ' s S M , D S M S y n c M o d u l e s o r W h e e l o c k ' s PS-12/24-8 Power Supply with built-in Patented Sync Prot o c o l . T h e s t r o b e s s h a l l n o t d r i f t o u t o f s y n c h r o n i z a t i o n a t a n y t i m e during operation. If the sync module or Power Supply fa i l s t o o p e r a t e , ( i . e . , c o n t a c t s r e m a i n c l o s e d ) , t h e s t r o b e s h a l l r e v e r t t o a non-synchronized flash-rate. The appliance shall also be d e s i g n e d s o t h a t t h e a u d i b l e s i g n a l m a y b e s i l e n c e d w h i l e m a i n - taining strobe activation. The Series AS Audible Strobe and Series AN Audible shall i n c o r p o r a t e a P a t e n t e d U n i v e r s a l M o u n t i n g P l a t e t h a t s h a l l a l l o w mounting to a single-gang, double-gang, 4-inch square, 1 0 0 m m E u r o p e a n t y p e b a c k b o x e s , o r t h e S H B B S u r f a c e 8 a c k b o x . I f required, an NATP (Notification Appliance Trimplate) shall be p r o v i d e d . All notification appliances shall be backward compatible. Specifications and Ordering Information Model Order Code Strobe Candela I Non-Sync 5' w1SM,DSM or PS-1 212" 24 12 VDC VDC Wall Mount Ceiling Mount Mount!ng Options AS-24MCW-FR - 9024 15/30/75/110 X X X - - A,B,DE,F,GH1,N,O,R,X AS-24MCW-FW 9025 15/30115/110 X X X - -. A,B,D,E,F,G,HJN,OR,X AS-241575W-FR 7405 15 (75 on Axis) X X X - - A,B,D,EF,G,l-LJ,NO,R,X AS-121575W-FR 7410 15 (75 on Axis) X X - X X - A,B,D,E,F,G,l-IJN,O,R,X AS-2415C-FW AS-2430C-FW 7411 7412 15 30 X X X X X - X - - - X X ABD,E,F,G,MJ,N,OX AB,DE,F,G,HJ,NO,R,X AS-2475C-FW 7413 75 X X X - - X ABD,E,FGj-LJ,NO,PcX AS-24100C-FW 7414 100 X X X - - X AS,D,E,FGi-i,JNORX ASWP-2475W-FR 9012 75 © -31 T X X X - - I (see Data Sheet S9004 AH-24-R 7892 - X X X - X X AB,D,E,FG,ftJNO,R.)( Al-1-12-R 7891 - X X - x X x A,B,D,E,F,G,t-I,J,N,o,RX AH-24WP-R 7416 - X X X - X X K AH-I2WP-R 7415 - X X - X X x K Refer to Data Sheet S7000 for Mounting Options. **For Weatherproof Series AS/AN specifications see data sheet S 9 0 0 4 . Note: Models are available in either Red or White. Contact Customer Service fo r O r d e r C o d e a n d D e l i v e r y . NOTE: Due to continuous development of our p r o d u c t s , s p e c i f i c a t i o n s a n d o f f e r i n g s a r e s u b j e c t t o c h a n g e w i t h o u t notice in accordance with Wheelock Inc. standard t e r m s a n d c o n d i t i o n s . WE SUPPORT AND ENCOURAGE NICET CERTIFICAT I O N NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: lnfo@wheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY Made in USA Distributed By: WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880. FAX: 732-222-2588 S8100 REV. 1103 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM O LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing -Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and - 24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and ;jOOC audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens le ttering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW audible/strobe, followed by any two alpha or numeric character indicating . lettering and product color. Model ASWP-2475W audible with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP -2575W is also suitable for outdoor use. RATING: Electrical 8-17.5/16-33 VDC/VFR AH-12, AH-12WP: 10.5-15.6 VDC, AH-24: AH-24WP:18-31 VDC Candela 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd,1 00:100cd, 110:110cd AS-24MCW: Selectable 15cd, 30cd, 75cd, llocd *Rev. 06-04-01 Listing No. 7125-0785:131 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. *Models ASWP -2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -c are for ceiling mount only. MARKING: Listees name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM -12/24, SMX-1 2/24, DSM -12/24 or DSMX-1 2/24 sync control module (CSFM Listing No. 7300 - 0785:132). These appliances can produce a distinctive three pulse Temporal Pattern fire Alar m Evacuation Signal (for total evacuation) in accordance with NFPA 72, 199 9 edition. NOTE Models ASWP-2475W, AH-1 2, AH-24, -1 2WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 06-04-01 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation IL_......JJ criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. A REND, Senior Deputy Program Manager S PAGE Series 1761 C3 Fire Protective Al eflireP Underwriters UL) Laboratories Inc.® \.J Listed Type FPLP C D For use in accordance with Article 760, Sections A & C, and with Article 725, Class 2 & 3 circuits for floor warden and fire control stations, smoke detection, voice communications, supervisory and all associated systems. S S U Fully Color Coded 60°C 7161-0972-100. plenum approved PVC U Color Code see Table V. insulation. U Solid bare copper conductors. Cl Manufactured in accordance with UL Subject 1424 and Cl 60°C plenum rated PVC the National Electric Code, jacket. Article 760 Sections U State of California State Fire 760-51(d) & 760-53(a). Marshall approval number 1761-22-1-4J 4 .129 16 1761-22-1-6J 1 6 .147 21 1761-22-1-8J 8 .166 27 1761-22-1-10J 10 .184 33 - 1761-22-1-12J 12 .200 28 1761-22-1-16J 16 .237 51 i ILVi'Letis p 'i.i :J: 11I 'P11 AaLllm 1761-18-1-2J 2 .141 32 1761-18-1-4J 4 .165 49 1761-18-1-6J 6 .211 69 .1761-18-1-8J 8 .255 101 CATALOG NUMBER NOMINAL WEIGHT NUMBER OF CONDS 0.0. LBS/MFT #16 AWG SOLID CABLED AND JACKETED 1761-16-1-21 162 1761-16-1-41 .191 1761-16-1-61 .242 #14 AWG SOLID CABLED AND JACKETED EBB #12 AWG SOLID CABLED AND JACKETED tIE 0 WIRE & CABLE CORP 133 South Van Norman Rd. • Montebello, CA 90640 • (800) 423-4659 • (800) 352-4335 (CA) • Fax (562) 692-9203 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: 7161-0972:100 Page 1 of 1 CATEGORY: LISTEE DESIGN: Cables-Fire Protective Signaling Atlas Wire & Cable, 133 S. Van Norman Rd., Montebello CA 90640 Contact: Tony Sanders (213) 723-2401 Fax (562) 692-5176 Model FPL, FLPR and FPLP power limited fire protective signaling cables. Conductors: Two or more conductors Insulation: Solid SRPVC, North America Plastics, Grade "NORPLAS" 21570 and/or Gitto/Global Corp, garde GA-8705-03P, Synergistics, Grade 1360-1021-PlD. Shield: Polyester film bonded to a aluminum foil; serving, wrap or braid of aluminum wire or of metal-coated or uncoated copper wire (optional). Jacket: PVC, North American Plastics, Grade "NORPLAS" 882A or Gitto/Global Corp., Grade GA-8705-03, or Senergistics, Grade 1690-1060 PJD, Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. Listee's name, Type "FPL", "FPLR", "FPLP", and UL label. Listed as power-limited fire protective signaling cables. INSTALLATION: MARKING APPROVAL: *Rev. 04-29-97 This is listing s based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 20, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. A REND, Senior Deputy Program Manager S S fO,2aX' CONSTRUCTION ELECTRONICS INCORPORATED ISIS PHARMACEUTICALS 1890 RUTHERFORD ROAD CARLSBAD, CA Equipment Submittal For Fire Alarm Tenant Improvement Prepared by: Construction Electronics, Inc. 13715 Stowe Dr. Poway, Ca 92064 April 18, 2002 13715 Stowe Drive Poway, CA 92064 Tel. (858) 513-0200 Fax (858) 513-1220 e-mail: cei@c-e-i.com Contractor Lic. #4176t 7 Security Lic. #PCO 1127 Equipment List Device Manufacturer Part Number CFM Listing Fire Panel Notifier AFP-400 7150-0028:182 Annunciator Notifier LCD-80 7120-0028:156 Control Module Notifier FCM/FRM Series 7300-0028:202 Monitor Module Notifier FMM Series 7300-0028:202 Pull Station Notifier NBG-12LX 7150-0028:199 Thermal Detector Notifier FST-75 1 7270-0028:196 Smoke Detector Notifier FSP-751 7272-0028:206 Strobe Wheelock RSS Series 7125-0785:141 Horn/strobe Wheelock AS Series 7125-0785:131 Power Supply Wheelock PS-12/24-8 7315-0785:149 Plenum Wire Atlas Wire 1761 Series 7161-0972:100 Fire Wire Atlas Wire 202 Series 7161-0972:100 0 December 6, 2000 DN-5262 A-103 J&FP-300 and AFP-400 Analog Fire Panels Section: Intelligent Fire Alarm Control Panels GENERAL The AFP-300 and AFP-400 are compact, cost-effective, in- telligent fire alarm control panels with a total capacity of up to 563 points and an extensive list of powerful features. The AFP-300/400 integrates conventional output circuits, such as notification, telephone, and speakers, with the intelligent features of one or two signaling line circuits (SLC) and 198 or 396 intelligent/addressable points. FEATURES One loop (AFP-300) or two loops (AFP-400) Style 4, 6 or 7. 198 intelligent devices per loop (99 intelligent detectors and 99 intelligent modules). 396 intelligent device capacity on the AFP-400; 198 on the AFP-300. VIEW®, HARSH TM, Advanced Multi-Sensor (AMS) op- tions. Up to 68 internal circuits/relays, plus 99 programmable zone output relays for a total capacity of 563 points. Four integral Notification Appliance (signal) Circuits (NACs), Style Z or Y (Class A or B). 6.0 A power supply, plus 6.0 A expanders. NACs may be programmed for Steady, March Time, Tem- poral, California code, or Canadian Two-Stage. Modified California code, pulsed on time. Tornado Warning activates different Notification Appli- ance Circuit code. Alarm, Trouble, Supervisory, and Security relays, stan- dard. Peer-to-peer network-ready. Intelligent features: a-' Manual sensitivity adjustment - 9 levels. ,/ Pre-alarm AWACS - 9 levels. a.' Day/Night automatic sensitivity adjustment. V Drift compensation (U.S. Patent Pending). V Multi-detector algorithm involves nearby detectors in alarm decision (patent pending). V Auto detector test (meets NFPA 72). a-' Maintenance alert (two levels). V Self-optimizing pre-alarm adjusts pre-alarm level to environment automatically. V Activate local sounder base on pre-alarm. a.' LED blink control for sleeping areas. g/ Automatic device type check. V Trouble after 20 detector verifications. Releasing features: V Ten independent hazards. a.' Sophisticated cross-zone (three options). V Delay timer and Discharge timers (adjustable). a.' Abort (four options). California State Fire Marshal 7170-0028:182 LISTED CS118/733 7165-0028:181 S635 FM City of M EA < > Chicago 17-96-E (AFP-400) Approved CLASS 1: 1291E 17-96-E Vol. II (AFP-300) CLASS 2: 1729E Sensitivity windows: a.' ION - 0.5 to 2.591o/foot obscuration. a.' PHOTO - 0.5 to 2.35%/foot obscuration. a.' MULTI-SENSOR - 0.71 to 4.0%/foot obscuration. a.' VIEW® - 0.03 to 1.0%/foot obscuration. Low-pressure CO2 support: a.' Expanded soak timer— 0 to 9999 seconds. a" Manual release delay (10 seconds) type ID. a.' "Second shot" monitor module type ID. a-' Triple-coded notification circuit type ID. Voice and telephone features: a.' Solid state message generation. a-' Hard-wired voice centrolmodule options (System 5000 class modules). a.-' Distributed voice options (XP transponders). V Firefighter telephone option. V 30- to 120-watt high-efficiency amplifier. a.' Backup tone generator and amplifier option. a-" Dual channel option. Telephone control module type ID. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAx: (203) 484.7118 i =1 . = •i H OTI Fl E re 12 Clintonville Road, Northford, Connecticut 06472 [NGINEERINC & MANUFACTURING Made in the U.S.A. DN-526212I06I00 - Page 1 0110 (S FEATURES, con finued Optional UDACT, 396-channel digital alarm communi- cator transmitter with AC fail delay. 80-character displays (up to 32) for remote annuncia- tion. ACS annunciators (EIA-485), including LDM custom. Two-wire detector interface provides compatibility with many manufacturers' detectors for retrofit applications. Integral printer interface (80-column and 40-column print- ers). Integral 80-character LCD display, backlit (2 lines x 40 characters). Field-programmable on panel or on PC, with program check, compare, simulate. Full QWERTY keypad behind flip-down door. Autoprogramming and Walk Test. Identifies two devices set to the same address. History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. Programmable waterflow or supervisory selection per point. Programmable combo zone - allows tamper and waterflow detectors to connect to a common monitor module. Alarm Verification selection per point, with tally. Verification Trouble counter. Trouble indication after a detector verifies 20 times. Programmable Positive Alarm Sequence (PAS) Presignal per NFPA 72. Silence inhibit and Auto Silence timer options. Programmable non-alarm points for lower priority func- tions. Remote ACK/Silence/Reset/Drill via addressable mod- ules. Maintenance Reports may be sorted via PC by compen- sation value (dirty detector), peak alarm value, or ad- dress. Automatic time control functions, with holiday excep- tions. Dual rate charger for up to 90 hours of standby power. Rapid poll algorithm for manual stations. Responds to alarm/activation in less than three seconds. SLC loop maximum length 10,000 feet (3,048 m) @ 12 AWG (3.25 mm'). Surface Mount Technology (SMT) electronics. High-speed RISC 16-bit microprocessor. Extensive built-in transient protection. (~ 0 Page 2oulO - DN-5262 12/06/00 Up to 68 fully programmable output circuits UP cJ TO E 32 [ LCD-80 Remote Display/Control RS-485 — — — — — — — — - - - E Photol F751 R Advanced — — — — — — — — — — - NBG-12LX FMM-1 Thermal Thermal ROR Multi-Sensor I DC RS 485 640 annunciator/control points uci J uurii UJILILJflJ JnnJ-I .SLC Intelligent Loop 1 Ion Photo FST-751 Thermal -----------NBG12LX Fixed FMM-1 FCM-1 XP Transponder SLC Intelligent. Loop 2 JDC NAG H1DUOiI3ILi _____________ 1111111 IMIM t;• ai, riui I .1tJU IEI MR L11J L11J 1JLU!J L11J 1JLIE Lii1 UL11JL11J IJL11J 1IlJ 1J111J IIJ 1J , Relay Control ACMIAEM-16AT LED Annunciator 0 0 0 0 1 0 1° _ L 0 0 LDM-32 Custom Graphics Dual phone lines to Central Station FCM-1 NAG 0 Le XP Transponder o SAMPLE SYSTEM BLOCK DIAGRAM cD AFP-400 shown in CAB-C3 with voice alarm system RS-232 RS-232 Terminal PRN Printer El CRT-2 Terminal I M S [ses.ozSs. ] I ALARM ''1 ALARM ?1 -SVSTEU.'-,,J LAMP ISTEP +MWLA4 I fll LM:fflTfrtl RESET C9 ,tsr ---------------------- 80-Character (2 x 40) Back-Lit LCD Display "- Status LED's -- Control Switôhes Programming Keypad Flip-Down Door (covers the programming keypad) Slide-in Label EPROM The CPU-300/400 EIA-232 EIA-485 Port SLC Loop #1 ElA-232 Terminal Port Terminal Mode" EIA-485 (Style 4, 6, or 7) SLC Loop #2 (AFP-400 only) Printer Port Port (Style 4,6, or 7) The MPS-400 Main Power Supply 2 non-resettable Resettable 24 VDC circuits 24 VDC rated 1.25 amps 1.25 amps* each* Battery (12-60 A.H.) Form-C Alarm, Trouble, Supervisory, and Security contacts. (3 amps @ 30 VDC) (Note: Supervisory and Security contacts can be converted to alarm contacts.) NAC or Releasing circuits I & 2. Class A or Class B, 24 VDC @ 2.5 amps each.* NAC or Releasing 00 Circuits 3 & 4. Class A or B, 24 VDC @ 2.5 amps each. AC Power 120/240 (Field Selectable) - *The MPS-400 is a 6 amp power supply. Total power, I including internal modules, I I cannot exceed 6 amps. JM 0 a UZC Coder Input _______ Door Tamper Switch (STS-200) Meter Module Option (MPM-2) Page 4 of 10 - DN-5262- 12/06/00 Status/Trouble LEDs Optional Transmitter module (4XTM connector). AWACSTM Advanced Warning Addressable Combustion Sensing AWACSTM is a set of software algorithms that provide the AFP-300/400 with industry-leading smoke detection capability. The development of these sophisticated algorithms are made possible by the close cooperation between Notifier and System Sensor, the world leaders in fire detection and alarm technology. These complex algorithms require many calculations on each reading of each detector, and are made possible by the very high speed microcomputer used by the AFP-300/400 (16-bit RISC Reduced Instruction Set Computer). 0 Drift Compensation and Smoothing. These algorithms (U.S. patent pending) identify and compen- sate for long-term changes in the analog readings from each smoke sensor. Long-term changes are usually Analog caused by dust accumulation inside the smoke chamber. Reading Drift compensation allows the detector to retain its origi- nal ability to detect actual smoke, and resist false alarms, Alarm Level even as dirt accumulates. It reduces maintenance re- - ------------------- quirements by allowing the system to automatically per without compensation - form the periodic sensitivity measurements required by with compensatwn NFPA Standard 72. Smoothing filters are also provided and smoothing by software to remove transient noise signals, usually caused by electrical interference. Different smoothing Time (days) Awncsl.wmf algorithms are used, depending on the sensitivity selec- tion of each detector. @ Maintenance Warnings. When the drift compensation ( DIRT performed for a detector reaches a certain level, the performance Urgent 0 Maintenance of the detector may be compromised, and special warnings are given.. There are three warning levels: (1) Low Chamber value, Maintenance usually indicative of a hardware problem in the detector; (2) Main- Alert tenance Alert, indicative of dust accumulation that is near but Acceptable below the allowed limit; (3) Maintenance Urgent, indicative of Range ( dust accumulation above the allowed limit. The Maintenance Alert level allows maintenance before the performance of the device is compromised. Low Chamber Reading —* O Sensitivity Adjust. Nine sensitivity levels are provided for I alarm detection. These levels can be set manually, or can change L automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control functions that are a subset of the alarm control program. O Self-Optimizing Pre-Alarm. Each detector maybe set for "Self-Optimizing" pre-alarm. In this special mode, the detector Prealarm Threshold "learns" its normal environment, measuring the peak analog read- ings over a long period of time, and setting the pre-alarm level just above these normal peaks. This allows extremely sensitive pre- alarm capability with reasonable protection against non-fire sig- Normal Threshold nals. Awaos4wrnf @ Cooperating Multi-Detector Sensing. A unique feature Time (days) of AWACSTM is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. z Using logic algorithms, each sensor can include up to two other Alarm sensors in its decision. Without statistical sacrifice in the ability - - -- to resist false alarms, it allows a sensor to increase its sensitivity Combined . to actual smoke by a factor of almost 2 to 1. Multi-detector sensing 3 Sensors also allows the combination of ionization with photoelectric tech- w nology in reaching an alarm decision. o ------------ - Time (minutes) 5262aw5.w,nf DN-5262 • 12/06/00 — Page 5 of 10 I FIELD PROGRAMMING OPTIONS AUTOPROGRAM a special software routine that allows the 300/400 to "am" Autoprogram is a timesaving feature of the 300/400E e . It is - lTJTORROGRPM.FLEEELJRIT I what devices are physically connected and automatically load them in the program with default values for all param- eters. Requiring less than 30 seconds to run, this routine -- -- - allows the user to have almost immediate fire protection in L1: [P15,. 15 NOES L: T LETS -3 ,. 5 MOOS. a new installation, even if only a portion of the detectors F4HEL OUTPUTS: 24 SELLS: 04 are installed. The routine will find all intelligent detectors -- and modules, and present them to the installer for edit of the default option selections, if desired. If a device is found that already exists in memory, autoprogram skips over that device (only new devices or missing devices are presented to the installer). Often the installer will perform autoprogram as a first step in a new installation, then upload the program into a PC to add all custom labels and other information, then download from the PC to the 300/400. KEYPAD PROGRAM EDIT ., The 300/400 has the exclusive feature of full program E.HTEE FROO OR STPT THEtc creation and edit capability from the front panel keypad, ENTER ESCSPE TI:' PEU PT 1 while continuing to provide fire protection. The archi- tecture of the 300/400 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be en- 2=C. LE 1=4L1111 2FUIHT 2F S,LILr 4MEEE'E tered with independent per-point segments, while the 300/ =IriHE E=S-PL LHCT T=.5TEt1 HE1. PRO, 400 simultaneously monitors other (already installed) points for alarm conditions. In addition to avoiding system shutdown, program edit from the panel keypad has the advantage of not requiring an on-site PC. This can save significant installation time for minor program changes. The 3001400 site-specific program is password pro- tected, and all information is stored in nonvolatile memory. Menu "trees" are provided to lead the trained installer through the program steps without the necessity to refer to the programming manual. VeriFireTM Software PC software is available for off-line programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific soft- ware. VériFirelM is a Windows®-based program provid- ing technologically advanced capabilities to aid the in- staller. The installer may create the entire program for the 300/400 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. The program includes error checks for common program- ming mistakes, such as an input point that does not acti- vate any outputs, or an output point that is not linked to any inputs. It also includes a simulation routine that will list all of the output points that are activated by a particu- lar input point (alternatively, it will list all the input points that are linked to a particular output). Although this does not eliminate on-site testing, it greatly increases confi- dence in the final installation. For example, a 200-input and 100-output point system, without using the software, could require 20,000 test observations to verity all pos- sible I/O links. Mr 1 H --.- -- -------------- fl rr V -r II WL l2 'iii-L or r..a I._oLAo.o,Ø LIN- I II 0 M$I4r M,tfle,00, '0 LJ'"' Nrf'rti0CItt o,001ort,rr. , The software includes a compare routine, pictured at right, that can also greatly help the installer. When a new program is created, it may be compared with a previous version and differences are highlighted. If the program is modified from the panel keypad, it may be uploaded into the PC, and compared with the previous version stored on disk. The identification of program differences greatly helps the installer in testing the installation. NFPA 72 requires that reacceptance test of a fire alarm system be performed on 100% of all points that are "known" to be modified. The software allows the installer to determine the exact points that are changed. Page 6 of 10 - DN-5262 12/06/00 -.-------- -.------------ iu: .............................-- L17 (S ('S BASIC EQUIPMENT PACKAGES There are two packages available to configure an AFP- 300 or 400 system. The standard model, BE-300 or BE-400, is designed to mount in a NOTIFIER full-sized cabinet in the CAB-3 Series. The BE-300AA or BE- 400AA is miniature package designed for a smaller cabinet, the CAB-400AA. Order one of the following BE packages: BE-400: Base Equipment includes the CPU (2 loops) module (CPU-400), an 80-character display, program- ming keypad, MPS-400 main power supply, installation instructions, chassis and required hardware. Order CAB-3 Series cabinet separately. BE-400AA: Base Equipment for use with CAB-400AA mini cabinet. It is similar to BE-400 but for use in smaller cabinet. Includes MPS-400RB and transform- ers. Supports one output option module. Order CAB- 400AA cabinet separately. BE-300: Base Equipment includes the CPU (hoop) module (CPU-300), an 80-character display, program- ming keypad, MPS-400 main power supply, installation instructions, chassis and required hardware. Order CAB-3 Series cabinet separately. BE-300AA: Base Equipment for use with CAB-400AA mini cabinet. It is similar to BE-300 but for use in smaller cabinet. Includes MPS-400RB and transform- ers. Supports one output option module. Order CAB- 400AA cabinet separately. CAB-3 Series: The AFP-300/400 utilizes CAB-3 Series cabinets (see data sheet DN-3549). SYSTEM MODULES The AFP-300/400 includes the ability to communicate with up to 8 conventional modules each with up to 8 circuits. Any mix of notification, relay, speaker, or tele- phone may be used. Choose any combination of up to eight output modules: 1CM/ICE, CRMICRE, DCM-4 or VCMIVCE. ICM-4: Notification Appliance Circuit Module, provides four Style Y or Style Z alarm Notification Appliance Circuits. Maximum signaling current is 3.0 amps per circuit or 6.0 amps per module, subject to power supply limita- tions (includes auxiliary power harness, LIi EE1 ELRs and slide-in labels). Includes ON! EIELJ OFF controls and ON/OFF LEDs. CRE-4: Control Relay Expander, expands CRM-4 to provide a total of eight (8) Form-C 1111$ relay contacts. (Maximum of one per CRM- I 4.) May also be connected to add four ! relays to 1CM-4, TCM-2, TCM-4, or VCM-4. VCM-4: Voice Control Module ______ provides four Style Y or Style Z speaker circuits, eight manual select switches and indicators, slide-in labels, and plug-in terminal blocks. Move jumper to convert to telephone circuits with remote ring signal and local call-in flash. May be expanded to 8 circuits with VCE- 4, ICE-4, or CRE-4. VCE-4: Voice Control Expander adds four circuits to VCM-4. (Note: VCM-4 / VCE-4 combination must be 8 speaker or 8 phone circuits.) LJEJ OTHER OPTION MODULES ARM-4: Auxiliary Relay Module, four (4) Form-C relays controlled by a relay module (CRM-4 or CRE-4). N. 0. contacts rated 20 amps, N.C. contacts rated 10 amps at 125 VAC and 30 VDC. (Maxi- mum of one for each CRM-4 or CRE-4.) VCC-1: Voice Control Center. Provides a variety bf user selectable tones on a single channel. Up to two different tones or messages may be selected on a single channel. Also provides optional digital voice message capability and on-site programmable voice messages. Includes Audio Message Generator (AMG- 1) microphone, cables, dress panels, and instructions. VCC-2: Voice Control Center. Single or dual channel Audio Tone Generator (ATG-2). Provides a slow whoop, Hi/Lo or steady tone on the primary channel and for dual channel applications, provides a chime or 20 pulse-per-minute tone on the secondary channel. Includes cables, microphone, dress panel, and instructions. VTCC-1: Voice/Telephone Control Center. Provides all that the VCC-1 provides plus two-way Fire Fighter's Telephone (FFT-7) capability. VTCC-2: Voice/Telephone Control Center. Provides all that the VCC-2 provides plus two-way Fire Fighter's Telephone (FFT-7) capability. TCC-1: Telephone Control Center. Provides a stand- alone two-way Fire Fighter's telephone (FFT-75). Includes cables, dress panel and instructions. AMG-E: Audio Message Generator (without microphone). Order in addition to VCC-1 or VTCC-1 if two-channel system is required. ° !CE-4: Notification Appliance Circuit Expander, expands ICM-4 to provide a total of eight (8) Style Y or Style Z alarm Kill ill ill Notification Appliance Circuits. Circuit ratings are same as 1CM-4. (Maximum of one per ICM-4.) May also be used to add four Notification Appliance Circuits to VCM-4. CRM-4: Control Relay Module, four (4) .S Form-C relay contacts, rated at 5.0 A, 120 VAC or 28 VDC (resistive) per circuit. Includes manual ON/OFF controls and LEDs LEI Pill 1414 DCM-4: Dual Channel Module provides four Style Y or Style Z speaker circuits plus four channel A/B select relays. Not expandable. _______ DN-5262• 12/06/00 - Page 7 of 10 MPS-400: Power Supply module. The 14PS-400 includes 4 Notification Appliance Circuits (NA C) that can connect four Class A (Style Z) or Class B (Style Y) circuits. The NAC also can be used for Releasing applications. Includes four built-in system relays (alarm, trouble, security, and supervisory). For BE-400 replacement only. The MPS-400 is included in the BE kits. MPS-400RB: MPS-400 PC board only. Less trans- formers and mounting chassis. AGENCY LISTINGS AND APPROVALS See the first page of this catalog sheet for listing agencies and file numbers. These listings and approvals apply to the basic AFP-300 or AFP-400 control panel. In some cases, certain modules may not be listed by certain ap- proval agencies, or listing may be in process. Consult factory for latest listing status. The AFP-300/400 is UL Listed, per Standards 864 (Fire) and 1076 (Burglary). It meets NFPA 72 Local, Auxiliary, Remote Station, Proprietary, and Emergency Voice/Alarm Fire Sys- tem Requirements. SPECIFICATIONS Primary input power, 120 VAC, 50/60 Hz, 3.0 Amps. Total output 24 V power - 6.0 A.* Standard Bell circuits (4) per MPS-400 - 2.5 A each. Four-wire detector power - 1.25 A. Two non-reset regulated power outputs - 1.25 A each. Battery charger range: 12 AH - 60 AH. (Use separate BB-55 cabinet for 55/60 AH batteries.) Charge high rate: 29.1 V. Float Rate: 27.6 V. Note: The MPS-400 has a total of 6.0 Amps of available power. This is shared by all internal modules and each MPS-400 circuit. SYSTEM CAPACITY: Unimode 400 Intelligent Signaling Line Circuits ................................2 Intelligent Detectors .................................................198 Addressable monitor/control modules.....................198 Programmable internal hardware and output circuits (four standard) ............................68 Programmable software zones ..................................99 * Special Programming zones .....................................14 Programmable remote relay/annunciator points.......99 LCD-80 annunciators per system (observe power) .. 32 ACS annunciators per system ... 10 Address x 64 points SYSTEM CAPACITY: Unmode 300 Intelligent Signaling Line Circuits ................................1 Intelligent Detectors ...................................................99 Addressable monitor/control modules.......................99 Programmable internal hardware and output circuits (four standard) ............................68 Programmable software zones ..................................99 Special Programming zones .....................................14 Programmable remote relay/annunciator points.......99 LCD-80 annunciators per system (observe power) 32 ACS annunciators per system ... 10 Address x 64 points CONTROLS AND INDICATORS Program Keypad: QWERTY type (keyboard layout). 8 LED indicators: AC Power; Fire Alarm; Pre-Alarm; Se- curity Alarm; Supervisory Signal; System Trouble, Disabled points, Alarm Silenced. Membrane Switch Controls: Acknowledge/Step; Silence; Evacuate; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED backlight. COMPATIBLE DEVICES, EIA-232 Port PRN-5 80-column printer. VS4095/S2 Printer, 40 column, 24 V. Mounted in exter- nal backbox (order from Keltron, Inc.). CRT-2 Video display terminal. NAM-232W Wire peer-to-peer NOTI • FIRE- NET" net- work interface module (see separate data sheet). NAM-232F Fiber peer-to-peer NOTI • FIRE • NET" net- work interface module (see separate data sheet). *VGAS Video Graphic Annunciator System (see separate data sheet). Note: * Not UL 864 listed (ancillary device only). COMPATIBLE INTELLIGENT DEVICES FSI-751 Ion detector. FSP-751 Photo detector. FSP-751T Photo detector with fixed thermal element. FST-751 Thermal detector, fixed. FST-751R Thermal detector, fixed and rate-of-rise. LPX-751 VIEW® detector. HPX-751 HARSHT11 photo detector (requires special base). IPX-751 Advanced multi-criteria detector (ion/photo! thermal). FSD-751P Duct detector, with housing. FSD-751RP Duct detector, with housing and relay. INTELLIGENT DETECTOR BASES B7IOLPBP Standard flanged base, package often. B5I0BP Standard flangeless base, package often. B7IOHD Base for HPX-751 (HARSHTM) only. B224RB Relay base. B224B1 Isolator base. B50IBH Sounder base. B50IBHT Sounder base with temporal sounder. COMPATIBLE ADDRESSABLE DEVICES NBG-I2LX Addressable pull station, visible LED. FMM-1 Monitor module. FMM-101 Monitor module, miniature. FDM-1 Monitor module, dual, two independent Class B circuits. FZM-1 Monitor module, two-wire smoke detectors. FCM-1 Control module. FRM-1 Relay module. DN-5262 12106/00 - Page 9 of 10 S S FFT-7IFFT-7S: Fire Fighter's Telephone control with master handset. S AA-30: Audio Amplifier - 30 watts. Switch-mode g power. Includes amplifier and audio input supervision, backup input, and automatic switchover, power supply, cables. o 0000 AA-I201AA-I00: Audio Amplifier provides up to 120 watts of 25 VRMS audio power for the AFP-400. The amplifier contains an integral chassis for mounting to a CAB-B3, -C3, or -03 backbox (consumes one row). Switch- mode power. Includes audio input and amplified output supervision, backup input, and automatic switchover to backup tone. Order the AA-100 for 70.7 VRMS systems and 100 watts of power. VROM-(n): Factory-programmed message for installation . in AMG-1. Provides up to 24 seconds of evacuation message on nonvolatile memory chip. - Choose one of many standard messages available. Up to two of - these' messages may be installed in one AMG. Includes VROM, 3576vrom.wmj instructions for installation and operation, and written text of message. VRAM-I: Field-programmed memory to be installed in AMG-1. Provides up to 24 seconds of field-programmable evacuation message on nonvola- tile memory chip. Message is V programmed from microphone or cassette tape. Up to two of these i5V 074Dvrawmf nonvolatile memory chips may be installed in one AMG. Includes VRAM and instructions for installation and operation. XPIQ: Intelligent transponder designed for multi-channel applications. (See XPIQ data sheet DN.6823.) Page 8 of 10 DN-5262• 12/06/00 UZC-256: Programmable Universal Zone Coder provides positive non-interfering successive zone coding. Microprocessor-controlled, field-programmable from IBM-compatible PCs (requires programming kit). (See UZC-256 data sheet.) LCD-80!LCD-80TM: 80-character, backlit LCD display. Mounts up to 6,000 ft. from panel. Up to 32 per AFP- 400. (See LCD-80, LCD-BOTM data sheets.) ACS: Annunciator Control Modules ACM-16AT, AEM- I6AT, ACM-32A, and AEM-32A. (See ACS data sheet.) AFM: Annunciator Fixed Modules AFM-16A, AFM-16AT and AFM-32A. (See AFM data sheet.) LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM- R32. (See LDM data sheet.) ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. from panel on four wires. (See ACM-SR data sheet.) RPT-485: Repeats EJA -485 over twisted pair or converts to fiber-optic medium. (See RPT data sheet.) XP: The XP Series Transponder provides conventional monitor and control points. (See XP data sheet.) CHS-4L: Low-profile four- position Chassis. Mounts two AA-30 amplifiers or one AMG- E and one AA-30. S I I = = = 5262ch4L.wmf CHS-4114: Expansion Chassis. Mounts up to four mod- ules. Includes CHS-4, MP-1 (Module Dress Panel), and Expander Ribbon Cable. DP-I: Blank Dress panel. Provides dead-front panel for 61 unused tiers or to cover AA- 30 AA-120 or AMG-E. 5262dp1.wmt CAB-3 Series: The CAB-3 Series cabinets are fabricated from 16-gauge steel with unique full-front LEXAN®, reverse silk-screened for durability. The cabinet assembly consists of two basic parts: a 10 backbox (SBB-_3), and a locking - door (DR-_3) that may hinge right or 5871ab3,,,,f left. Cabinets are arranged in four (4) sizes, A through D (B [two-tier] is pictured at right). A trim ring option is available for semi-flush mounting. (See CAB-3 Series data sheet.) LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. CAB-400AA: Provides small cabinet for CPU-400 and MPS-400RB. Use with BE-400AA only. Space for one (only) output circuit module plus expander. APS-6R: Auxiliary Power Supply expander). ( Provides up to 6.0 amperes of regulated power for compatible Notification appliance circuits. Includes battery input and J1 U transfer relay, and overcurrent protection. Mounts on one of four positions on a CHS-4L or CHS-4 chassis. • 5952cov.wn,f FCPS-24: The FCPS-24 is a remote 6- amp (4-amp continuous) repeaterl power supply. CHS-4: Chassis for mounting up to four APS-6R. XP5-M Transponder, monitor, five addressable Class B circuits. XP5-C Transponder, control/relay, five addressable Class B circuits. ISO-X Isolator module. NOTE: All addressable devices listed above may only be used with the AFP-300/400 software revision 3.61 or higher. COMPATIBLE DEVICES, RS-485 Port (see separate data sheets) ACS Series Remote Serial Annunciator/Control sys- tems. LCD-80 Remote LCD display. LDM Series Remote custom graphic driver modules. ACM-811 Remote relay module. 8 Form-C relays. NIB-96 Network Interface Board. RPT-485 Series Repeater, isolator and/or fiber optic mo- dem. UDACT Universal Digital Alarm Communicator Transmitter. UZC-256 Zone Coder. Up to 256 programmable codes. OTHER ACCESSORIES 4XTM Plug-in Transmitter Module. Provides municipal box and remote station con- nection. PS Series Batteries; the AFP-300/400 battery range is 12 AH to 60 AH. Refer to DN-1109. ROM-AFP400 Panel software upgrade kit. Includes latest factory software (consult factory). BB-55(F) Battery Box (required for 55/60 AH). • Order "F" suffix for red cabinet. VeriFire-CD Programming kit for PC. Includes CD, cable, and instructions. VeriFire-CDUG Same as VeriFire-CD above except it does not include the cable. - Other options as listed in previous sections. (S (S (S Page 10 of 10 - DN-5262• 12106/00 CALIFORNIA DEPARTMENT OF FORESTRY & ARE PROTECTION OFFICE OF THE STATE ARE MARSHAL ARE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7170-0028:182 Page 1 of 2 CATEGORY: Control Units (High-Rise) USTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1001 Contact: Larry Flood (203) 484-1200 DESIGN: Models AFP-300 and AFP-400 fire alarm control units. Automatic, manual, coded, non- coded, local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU). Also suitable for waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: CPU-3001400 MPS-400 CAB-A31-B31-C31-031-400AA 4XTM BB-1 7/-55 MMX-1/-1 01 ISO-X N-ELRJA2143-00 C MX-1 XPP-1 /XPM-8/XPR-8/XPC-8 XPDP ACT-1 CRT-2 AA-30/-100/-120 AMG-1/-E ATG-2 DCM-4 FFT-71-7S FHS FPJ/-1 VCE-4 VCM-4 ARM-4 AVPS-24 CRE-4 CRM-4 FCPS-24 FKS-2400 ICE-4 NAM-232 * CPU Board Power Supply Board Enclosure Transmitter Module Battery box Monitor Module Isolator Module EOL Resistor Control Module XP Transponder Transponder Dress Panel Audio Coupling Transformer Terminal with Keyboard Audio Amplifier Audio Message Generator Audio Tone Generator Dual Channel Module Firefighter's Telephone Fireman's Handset Fireman's Phone Jack Voice Control Expander Voice Control Module Auxiliary Relay Module Audio/Visual Power Supply Control Relay Expander Control Relay Module Field Charger Power Supply Modem Indicating Control Expander Network Adapter Module Rev. 05-24-99 Listing No. 7170-0028:182 Page 2 of 2 lCM-4 NIB-96 NR45-24 RPT-48 5 F/-W/-WF UZC-256 MP-1 lOP-i /-3/-400AA DPSW-1 /DPDW-1 /DP-400 BM-1 TR-500 Indicating Control Module Network Interface Board Notifier Remote Battery Charger ElA-485 Repeater Universal Zone Coder Dress Panel Dress Panel Blank Module Trim Ring INSTALLATION: In accordance with Iiste&s printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control unit suitable for high rise application when used in conjunction with separately listed compatible initiating and indicating devices. Units can also generate the temporal code pattern as required per NFPA 72, 1996 Edition. NOTE: For 17iv Ak,m Verilkation Featw (Delay of fire alarm signal), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. S Rev. 05-24-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item. listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 21 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager LCD-80 (shown with ABF-1 flush backbox) can annunciate and provide remote reset, acknowledge, and silence of the control panel from remote locations. The DIA- 1010 and DIA-2020 (Display Interface) include a terminal mode driver port for LCD-80s in terminal mode. The Terminal mode port is standard on the AFP-400, AFP-300, and AFP-200 main PC/CPU boards. Displays device type identifiers. Device and zone custom alpha labels. Time/date and Device address. May operate in addition to CRT. No programming necessary. LCD-80 displays time, date, and custom messages received from AM2020, AFP1010, AFP-400, AFP-300, or AFP-200. May 1, 1998 D-120 NOTIFIER® A Pittway Company LCD-80 Liquid Crystal Display Section: Annunciator Control Systems '•S GENERAL The LCD-80 is an 80-character, backlit LCD display annuncia- MEA U U C F M tor for the NOTIFIER AM2020, AFP1 010, AFP-400, AFP-300, 290-91-E AFP-200, System 5000, and System 500 fire alarm control QV7AO AY 289-91-E panels. Up to 32 LCD-80s may be connected onto the two- S635 CS100 wire EIA-485 port. The LCD-80 has two basic modes of 0p California eration, "Terminal" and 'ACS mode. no State Fire Marshal COMMON FEATURES 7120-0028:156 80-character Liquid Crystal Display (20 characters x 4 lines), backlighted. Control switches for System Acknowledge, Signal Silence and System Reset. Time and date display field. Enable Key switch and phone jack options. Can be remotely located up to 6,000 feet from the control panel. Local piezo sounder with alarm/trouble resound. Flush/surface/panel mount option. Optional RPT-485 repeater increases the distance and num- ber of LCD-80s in a system (see RPT-485 catalog sheet). Optional transmission over fiber optics (see RPT-485 cata- log sheet). ACS MODE When operated in "ACS mode, the LCD-80 provides a re- mote or local digital display and printer interface for the Sys- tem 5000 and System 500. For the AM2020, AFP1010, AFP- 400, AFP-300, and AFP-200, the LCD-80 provides a vectored annunciation capability. Individual devices/zones can be in- staller-defined to only display and print at specific locations (EXAMPLE: A maintenance office receives only non-alarm point activations. These inputs could be sump pump on, high water, backup AHU on, low temperature in freezer, etc.). Alarm/trouble count. Custom "normal" message. European option: first alarm/last alarm/alarm count. Field-programmable messages from CRT or PC-compatible computer (PK-LCD-80 Programming Kit required). ElA-485 interface: up to 32 per system. Printer output port: RS-232, compatible with PRN Series printers. Field-programmable messages in nonvolatile memory in two options: 128 points, 40 character labels; or 256 points, 20 character labels. Internal nonvolatile clock for time and date. AM2020, AFP1010, AFP-400, and AFP-300 'vectored" printer capability. Can be mounted in a System 5000 cabinet module position. TERMINAL MODE (AM2020, AFP1010, AFP-400, AFP-300, and AFP-200 ONLY) In Terminal Mode, the LCD-80 mimics the AM2020, AFP1010, AFP-400, AFP-300 and AFP-200 displays. Up to 32 LCD-80s This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all Specific applications or ISO.9001 anticipate all requirements. All specifications are subject to change without notice. For Engineering and Manufacturing more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 Quality System Certified to h) N OTE FE £ R 12 Clintonville Road, Northford, Connecticut 06472 International Standard ISO.9001 Made in the U.S.A. DN-3198 - Page 1 of 2 The LCD-SO in ACS Mode EIA-232, 4 wires 50 feet maximum ElA-485 EIA-485 EIA-485 (2 wires) (2 wires) (2 wires) 24 VDC Vr 24 VDC V 24 VDC (2 wires) (2 wires) (2 wires) flrnj cc TO TO TO PRN LCD-80 PRN LCD-SO PRN PRINTER PRINTER PRINTER System 5000, System 500, AM2020, AFP1010, AFP-400, orAFP-300 The LCD-SO in Terminal Mode System 5000 with panel-mounted LDC-80 LCD-80 is 8-1/4(20.96 cm) high, 4-3/8" (11.11 cm) wide, and 1-3/4" (4.45 cm) deep. Up to 32 LCD-80s may be used on one EIA- 485 circuit. NOTE: Must have sufficient regulated 24 volt p power. Certain NOTIFIER systems may have - limits to the amount of LCD-80s with ACKISTEP, \\ Signal Silence, and Reset switches. ) LCD-80 mounts with any CHS-4 chassis slot. The LCD-80 may display all System 5000 cir- PRN Printer cuits. Alternately, it may display up to 192 AIM-200 points and two rows of modules. 6,000 feet maximum total wire length. (S ABF-ID —The ABF-1D is a semi-flush-mount backbox for the NOTIFIER LCD-80 Series Annunciator., The ABF-1D mounts one LCD-80. It in- cludes an attractive smoked- glass door with NOTIFIER keylock. Dimensions, BOX only: 9-15/16" (25.24 cm) high, 4-5/8" (11.75 cm) wide, 2-1/2" (6.35 cm) deep. ( S 6,000 feet maximum wire length Terminal Mode between each LCD-80 EIA-485 (2 wires) • 24 VDC - (2 wires) LCD-SO LCD-80 LCD-SO Printer Port AFP1010, EIA-232 AM2020, L 4rl or AFP-200 r AFP-400, AFP-300, Terminal Mode EIA-485 return (2 wires) ) PRN Printer Up to 32 LCD-80s may be used in a continuous 4 Dimensions, DOOR only: wire loop (verify sufficient 24 VDC available). 10.713" (27.21 cm) high, Each may have ACK/STEP, SIGNAL SILENCE, 6" (15.24 cm) wide, and SYSTEM RESET switches. 0.75" (1.9 cm) deep. Displays all analog, addressable points. No programming required for LCD-80s. RELATED OPTIONS PK-LCD-80 Off-Line Programming Kit for LCD-SO. Allows PC programming messages when the LCD-SO is used in the ACS mode. CCM-1 Converter Module. Required for terminal mode operation on older AM2020s or AFPIO1 Os that do not include the DIA-2020 or DIA-1010 Display Interfaces. Also required forAM2020 and AFP1010 systems which require a CRT with keyboard. Uses one ICA-4 chassis slot or two CHS-4 chassis slots. ABF-ID Semi-flush box with alternative smoked-glass door, any keylock. ADP-4 Annunciator Dress Plate. Allows panel mounting of up to four LCD-80 modules in a CAB-X3 Series cabinet. ABF-1 Annunciator Flush Box, 9-15/16" (25.24 cm) high, 4-5/8" (11.75 cm) wide, and 2-112" (6.35 cm) deep. Order AKS-i key-switch and APJ-1 phone jack if desired. Can also be mounted in ABF-2 or ABF-4 annunciator backboxes. ABS-IT Deep Surface Backbox (mounts one LCD-SO). AKS-1 Keyswitch to enable/disable controls when mounted in ABF or ABS-1T. APJ-1 Annunciator Phone Jack. Mounts to ABF flush box or ABS-1T. PRN Series 80-Column Serial Printer. RPT-485W EIA-485 Wire Repeater. Increases wire distance between LCD-80s. RPT-485F ElA-485 Fiber-Optics Repeater. Increases distance and converts ElA-485 wire to fiber-optics. Page 012 - DN-3198 ( - S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:156 Page 1 of 1 CATEGORY: Annunciators LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 DESIGN: Model ACS annunciator control system. Refer to listee's data sheet for additional detailed product description and operational considerations. Unit consists of the following modules: ACM-I6AT, 16ATY*, 16ATG* Control Module ACM-32A', 32AY*, -32 AG* Control Module ACM-24A-r, ACM48A* Control Module AEM24AT*, AEM48A* Control Module AEM-I6AT Expander Module AEM-32A, ACM-32A Control Module AFM-I6AT, AFM-32A, AFM-16A Fixed Module ABM-I6AT, ABM-32A Blank Module ABS-1, -2, -1 B-, 2B*, 1T*, -iTB- Enclosures (Surface) ABF-1, -ID, -2, -21), 4, 1B*, ..2B*, 4B* Enclosures (Flush) ABF-i DB*, 2DB* Enclosures (Flush) ADP-4 Dress Panel AKS-1, -I B* Key Switch LCD-80, -80TM Control Panel LDM-32 Lamp Driver Module LDM-E32 Lamp Driver Expander LDM-R32 Lamp Driver Expander (Relay) ACM-8R Mappable Relay Control Module INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator system when used in conjunction with separately listed compatible fire alarm control units. *Rev. 1-7-2002 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: JANUARY 7, 2002 Listing Expires June 30, 2002 Authorized By: DIANE K. AREND, Senior Deputy &OTI Fl ER@ W FIRE SYSTEMS GENERAL FCM-1 Control Module - The FCM-1 Addressable Control Module provides NOTIFIER intelligent control pan- els a circuit for Notification Appliances (horns, strobes, speak- ers, etc.) or to monitor a telephone circuit. Addressabllity allows the FCM to be activated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1 Relay Module - The FRM-1 Addressable Re-lay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, damp- ers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan (patent pending) is a new communication pro- tocol developed by NOTIFIER Engineering that greatly en-hances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FEATURES Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM module requires power (for horns, strobes, etc.), audio (for speakers), or a telephone riser (for hand- sets). Internal relay feature available on FlashScan sys- tems only. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all de- vices). High noise immunity (EMF/RFl). The FCM may be used to switch 24-volt NAC power, au- dio (up to 70.7 VRMS) or telephone. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan, 01 - 99 on traditional systems. Speaker, audible/visual, and telephone applications may be wired for Class B or A (Style Y or Z). APPLICATIONS The FCM is used to switch 24 VDC audible/visual power, high-level audio (speakers), or control telephone devices. The FIRM may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to re- set four-wire smoke detector power. August 9, 2000 DN-6724 H-230 FCM and FRM Series Control and Relay Modules with FlashScanTM Section: Intelligent/Addressable Devices California State Fire Marshal 7300-0028:202 LISTED CS669 S3705 MARYLAND lvi EA State Fire Marshal 457-99-E Permit #2020 Approved (See wiring diagram Fig. 5 for FRM-1) CONSTRUCTION The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-159). The FCM is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM provides two Form-C dry contacts that switch together. OPERATION Each FCM or FIRM uses one of 159 possible module ad- dresses on a SLC loop, It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On FlashScanTm is a trademark of NOTIFIER. Noryl® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. S This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 • NO TI Fl EW One Fire-Lite Place, Northford, Connecticut 06472 ENGINEERING & MANUFACTURING DN-6724 08/09100 - Page 1 of 4 S MOUNTING DIAGRAMS Note CB500 Module Barrier, which creates isolated quadrant. ISOLATED QUADRANT Page 2 of 4 - DN-6724 '08/09/00 S command, it activates its internal relay. The FCM super- vises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM will discon- nect the supervision and connect the external power supply in the proper polarity across the load device. The discon- nection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The ex- ternal power supply is always relay isolated from the corn- municàtion loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a module and a sensor address. A built-in magnetic test switch is provided to simulate a short circuit on the NAC to test the FCM-1. SPECIFICATIONS for FCM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 390 pA (LED flashing). External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x4".(101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. SPECIFICATIONS for FM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity. range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. RELAY CONTACT RATINGS for both FCM and FR/if models Load Description Application Mamum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R = 5 ms) Coded 30 VDC 0.5 A Inductive (L/R = 2 ms) Coded 30 VDC 1.0 A Inductive (PF = 0.35) Non-Coded 1125 VAC PRODUCT LINE INFORMATION 67241a1e.tb FCM-1 Intelligent Addressable Control Module. FRM-1 Intelligent Addressable Relay Module. A2143-20 Capacitor, required for Class A (Style Z) op- eration of speakers. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier - required by UL for separating power-limited and non-power limited wiring in the same junction box as FCM-1. N, ( i11iT.Ti1TII.IT.TT.I1 The Face Plate .00 WIRING DIAGRAMS V The following wiring diagrams are provided: FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. FCM-1: Typical fault-tolerant notification appliance circuit con- figuration, NFPA Style Z. FCM-1: Typical wiring for speaker supervision and switching, .- ........................-• NFPA Style Y. © 4) FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. CAUTION 5) FRM-1: Relay module wiring diagram. DE-ENERGIZE UNIT PRIOR TO SERVICING Lz V Fig. I FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Communication Line 32 VDC max. Module polarities are shown in alarm. \ Twisted-pairis recommended. TO Next (—) FROM Panel Device +) or or PreviousCONTROL vice d MODULE 47K EOL 0 NOTLOOP wire I on terminals 3 & 4. Resistor I 9 ELR-47K Break wire to provide (-) C-) 7 supervision of connections. rJ5 49 (+) 24 VDC OWES LOOP ADDRESS POWER °e9 SUPPLY ( +) (+) Power Supply: Isolated, regulated, UL listed EOL Relay TO NEXT control module or EOL Relay. power-limited per NFPA 70. shown ONE RELAY REQUIRED for each circuit. Listed for fire protection nroized Some control panels have the RELAY BUILT IN 24 VC coil and do not require external wiring. WILU OLLUy DWp. A77-716B Refer to the NOTIFIER manual. V Fig. 2 FCM-1: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Communication Line 32 VDC max. Module polarities are shown in alarm. \ Twisted-pair is recommended. n S TO Next Device CONTROL EOL Resistor is internal at d MODULE terminals 8 & 9 \ 60 7EWS 2 30 5 4 ONES LOOP AOORESS E) o9 (+) (+) UL listed EOL Relay TO NEXT control module or EOL Relay. shown ONE RELAY REQUIRED for each circuit. energized Some control panels have the RELAY BUILT IN 14 24 VDC coil and do not require external wiring. A77-716B Refer to the NOTIFIER manual. FROM Panel or Previous 14 Device 24 VDC Circuit / DONOTLOOPwjre / on terminals 3 & 4. Break wire to provide supervision of connections. 24 VDC POWER SUPPLY Power Supply: Isolated, regulated, power-limited per NFPA 70. Listed for fire protection with battery backup. *1 DN-6724 . 08/09/00 - Page 3 of 4 V' Fig. 3 FCM-1: Typical wiring for speaker supervision and switching, NFPA Style Y. Connect modules to listed compatible Communication Line 32 VDC max. Twisted-pair recommended. S NOTIFIER control panels only. TO Next Device FROM Panel All wiring shown is supervised. or Previous Wires must be supervised per NFPA. CONTROL Device Module polarities are shown in alarm MODULE A Audio Circuit DONOTLOOPwire on terminals 3 & 4. 47K EOL Resistor TENS I(_( Break wire to ensure () : supervision of connections. ELR7K 0 AUDIO AMPLIFIER 11:15 40 ONES 70.7 VRMS max. LOOP ADDRESS Use only models AA-30, orM-120. Amplifier must provide wiñno sunMsinn nr NFPA TO Next Speaker Switching Circuit: NFPA STYLE W Control Module SUPERVISION Speakers must be listed for fire protection. Last module must return 12 Refer to the Relay Contact Rating table for maximum load, wires for supervision. 6724wr3.wmf V Fig. 4 FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised. Communication Line 32 VDC max. Twisted-pair recommended. Wires must be supervised per NFPA. TO Next FROM Panel Module polarities are shown in alarm. Device (~) or Previous CONTROL Device EOL Resistor is internal at terminals 8 & 9. Bypass Capacitors: A2143-20, 100 pf, d MODULE Audio Circuit 16 V, non-polarized., < 10 pA leakage. DO NOTLOOP wire 9 on terminals 3 & 4. wire to ensure _______ 7 2-2 8(2 i s Break supervision of connections. TENS AUDIO AMPLIFIER ONES 70.7 VRMS max. LOOP ADDRESS Use only models AA-30, M-100, orM-120. Amplifier must provide Speaker Switching Circuit: NFPA STYLE X TO Next Control Module wiring supervision per NFPA. ESUPERVISION Speakers must be listed for fire protection. Last module must return - Refer to the Relay Contact Rating table for maximum load, wires for supervision. -i 6724w.wmf NOTES regarding AUDIO AMPLIFIER in Figures 3 & 4 above. Audio circuit wiring must be twisted-pair as a minimum. See NOTIFIER installation manual for detailed information. When a 70.7 V audio amplifier is used, terminals 1 and 2 are power-limited, while terminals 3 through 9 are non-power-limited. In this c a s e , the C6500 barrier is required. Otherwise, all terminal wiring is power-limited. The CB500 includes a label indicating which terminals are no n - power-limited. This label MUST BE PLACED adjacent to the nameplate label, which is on the module housing. TO Next ' (+) Device , I '\ 4 FROM Panel S I I S (+) or Previous Device RELAY -Communication Line MODULE -- — - 32 VDC maximum. - Shielded twisted-pair fl - is recommended. RELAY COMMON 2 _________ 9n NORMALLY CLOSED 2 Il84-4 NORMALLY OPEN 2 l7-1F 2i± 4 Fig. 5 RELAY COMMON 1 16 3 j FRM-1: Relay module S NORMALLY CLOSED 1 5 -k--1 1-4 t~j NORMALLY OPEN 1 wiring diagram. 1 LOOP . Connect modules to listed P o ADDRES 26724Mr5.wf compatible control panels only. Module does NOT supervise controlled circuits. Page 4 of 4 - DN-6724 08/09/00 ( CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models FMM-1, FMM-101, FZM-1, FSM-1 01, FDM-1 * monitor modules and Models FCM-1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number andUL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. S *Rev. 05-02-01 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable infomation sources. Date Issued: JUNE 18, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager FIRE SYSTEM & I GENERAL Four different monitor modules are available for NOTIFIER in- telligent controls to suit a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull sta- tions, or monitor and power a circuit of two-wire smoke de- tectors (FZM-1). FMM-1 - is a standard-sized module (typically mounts to a 4" [101.6 mm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. FMM-101 - is a miniature monitor module (a mere 1.3" (33.02 mm) H x 2.75" (69.85 mm) W x 0.5" (12.70 mm) 0) used to supervise a Class B (Style B) circuit. Its compact design allows the FMM-101 to often be mounted in a single- gang box behind the device it's monitoring. FZM4 - is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. FDM-1 - is a standard-sized dual monitor module used to monitor and supervise two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (patent pending) is a new communication protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog in- telligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FlashScan® is a registered trademark of NOTIFIER. FMM-1 MONITOR MODULE Built-in type identificatioh automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address 01 - 159 (01 - 99 on tradi- tional systems). LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1 Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 can be used to replace MMX-1 mod- ules in existing systems. November 13, 2000 DN-6720. H-220 FMM, FZM, and FDM Series Monitor Modules with FkishScan® Section: Intelligent/Addressable Devices California State Fire Marshal 7300-0028:202 LISTED C5669 (except FDM-1) S635 (except FDM-1) MEA MARYLAND State Fire Marshal Approved 457-99-E Permit # 2020 (except FDM-1) (except FDM-1) (except FDM-1) FMM-1, FZM-1, and FDM-1 FMM-1 Applications - Use to monitor a zone of four- wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for su- pervision of the Style D circuit. Maximum IDC loop length is 2,500 ft./762 m (20 ohms maximum). FMM-1 Operation - Each FMM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FMM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 400 lJA (LED flashing). 1] This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 H OTI Fl E R 12 Clintonville Road, Northford, Connecticut 06472 ENINEERlNC & MANUFACTURING DN-6720' 11/13100 - Page 1 of 6 EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C) Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. FMM-101 MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the AFC-600. - Powered directly by two-wire FACP. No additional power required. - High noise (EMF/RFI) immunity. - Tinned, stripped leads for ease of wiring. Direct-dial entry of address (01-159). The FMM-101 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101 is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101 can be used to replace MMX-101 module in existing systems. 1415 0 1 ADDRESS J 0 13 II It 2 12//7\\3It II 11W)))4I LOOP 1O"/5I I 8 7 6 J 8 7 6 J. TENS ONES I HI H co FMM-1 01 Applications Use to monitor a single de- vice or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normaly-open dry-contact devices. May also be used to monitor normally- open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101 Operation - Each FMM-101 uses one of 159 available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). FMM-101 Specifications Nominal operating voltage: 15 to 32 VDC. Average operating current: 375 pA maximum. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (33.02 mm) high x 2.75" (69.85 mm) wide x 0.5° (12.70 mm) deep. Wire length: 6"(152.4 mm) minimum. FZM-1 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address (01-159). LED flashes during normal operation (this is a program- mable option). LED latches steady to indicate alarm on command from control panel. The FZM-1 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional de- tectors back to the control panel. All two-wire detectors be- ing monitored must be UL compatible with the module. The FZM-1 has a panel-controlled LED indicator and can be used to replace MMX-2 modules in existing systems. FZM-1 Applications - Use the FZM-1 to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1 Operation - Each FZM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FZM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VRMS maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. FDM-1 DUAL MONITOR MODULE The FDM-1 Dual Monitor Module is intended for use in in- telligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecu- tive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally closed security devices. The module has a single panel-controlled LED. NOTE: The FDM-1 provides two Class B (Style Y) IDC circuits ONLY. Class A (Style Z) bC circuits are NOT supported in any application. FDM-1 Specifications Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 5.7 mA (LED on). Average operating current: 750 pA (LED flashing). Page of 6 DN-6720• 11/13/00 ARCH ITECTS'/ENG[NEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are available from NOTIFIER. CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING / Face Plate for FMM-1, FZM-1, and FDM-1 0=1 I MOUNTING DIAGRAMS For standard-sized modules % DN-6720• 11/13/00 - Page3of6 (I EOL resistance: 47K ohms. Maximum IDC wiring resistance: 1,500 ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 2.125' (53.975 mm) deep. FDM-1 Automatic Addressing - The FDM-1 auto- matically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1 is set to address "55", then it will automatically assign itself to ad- dresses "55" and "56". Terminals 6 and 7 use the first ad- dress, and terminals 8 and 9 use the second address. /jCAUTION! V Avoid duplicating addresses on the system. INSTALLATION FMM-1, FDM-1, and FZM-1 modules mount directly to a standard 4' (101.6 mm) square, 2.125" (53.975 mm) deep, electrical box. They may also be mounted to the SMBSOO surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The FMM-1O1 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable lo- cal codes, ordinances, and regulations. PRODUCT LINE INFORMATION Model Description FMM-1 Monitor module. FMM-101 Monitor module, miniature. FZM-1 Monitor module, two-wire detectors FDM-1 Monitor module, dual, two independent Class B circuits. S MB 500 Optional surface-mount backbox. L [I WIRING DIAGRAMS The following wiring diagrams are included: FDM-1, typical dual two-wire Style B initiating device circuit configuration. FMM-101, typical two-wire Style B initiating device circuit configuration. FMM-1, typical two-wire initiating circuit configuration, NFPA Style B. FMM-1, typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. FMM-1, typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). FZM-1, interface two-wire conventional detectors, NFPA Style B. FZM-1, interface two-wire conventional detectors, NFPA Style D. FRM-1, relay control module used to disconnect a power supply. (S Fig. I FDM-1: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits (dialed address "N" then 'N+ 1") TO Next " each power-limited to Device 230 pA max. @ 12 VDC max. MONITOR 47K EOL d MODULE . Resistor ffN: _11 ELR-47K 8(5 ij 47K EOL 6 3R Resistor IT N+1 E54 11 ELR-47K T LOOP ONES ADDRESS (-) FROM Panel (+) or Previous Device Communication Line 2 VDC maximum. Shielded/twisted-pair is recommended. All wiring shown is supervised and power limited. Connect modules to listed compatible NOTIFIER control panels only. ( S• -ANY NUMBER of UL Listed contact closure devices may be used. 6822wr1.wmf DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. Install contact closure devices per manufacturer's installation instructions. NEXT ___:~:7j TO ________ DEVICE I BLACKI I4 RED UL LISTED I I Compatible I I (-) () FMM101 Control 5 6789i0 56789 Panel 2 13 2—' 1 01514 10 VIOLET 4 YELLOW 47K EOL INCLUDED I Fig. 2 FMM-101: Typical two-wire Style B initiating device circuit configuration. 6720w1r1.wmf Page 4 of 6 - DN-6720• 11/13/00 (S Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Install contact closure devices per manufacturers' installation instructions. Any number of UL-listed contact closure devices may be used. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. V Fig. 3 FMM-1: Typical two-wire initiating device circuit configuration, NFPA Style B. TO Next Device (—) FROM Panel MONITOR (+) or Previous Device Initiating Device Circuit (IDC) ,.-'7 MODULE NFPA Style B, power limited: Communication Line 230 pA max. @ 12 VDC max. 9 0 0 — 32 VDC maximum. 8 Shielded/twisted-pair 47KEOL IEl7 TENS 2 is recommended. Resistor ELR-47K 6 3 5 10 4 Communication Loss LOOP ONES ADDRESS (optional connection for panels o 9 which support this feature) FUTURE FEATURE 6720w1r2.wmf V Fig. 4 FMM-1: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. EOL Resistor is internal at terminals 8 & 9 FROM Panel or Previous Device tion Line MUM. ted-pair Jed. anels B) 'V Fig. 5 FMM-1: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). Initiating Device Circuit (IDC) TO Next Device (+) (—) FROM Panel or Previous NFPA Style B, power limited: MONITOR Device 230 pA max. @ 12 VDC max. d MODULE Communication Line 14K Series Resistor 0 32 VDC maximum. 0 8 — Shielded/twisted-pair is 47KEOL EI7TENS 2 + recommended. Resistor 6 , 3 I.) Communication Loss ELR-47K LI 5 ONES LOOP ADDRESS (optional connection for panels ° o 9 which support this feature) FUTURE FEATURE 6725w1r4.w,,,t LUJ DN-6720 11113/00 - Page 5 of 6 Connect modules to listed compatible control panels only. WIRING • • Terminal wiring must be power limited. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. DIAGRAM DO NOT LOOP wire under terminals. Break wire run to provide supervision of connections. THIS PAGE: Detectors must be UL listed compatible with module. . Install detectors per manufacturers' installation instructions. Power to the interface module must be externally switched to reset the detectors. An FRM-1 relay control module can be used to switch power from a standard power supply; see Fig. 7 below. V Fig. 6 FZM-1: Interface two-wire conventional detectors, NFPA Style B. TO Next _____ ' 4 FROM Panel Device _____ (+) or Previous INTERFACE Device ME Communication Line Jfl 32 VDC maximum. Twisted-pair is recommended. 3.9K EOL Listed Battery Backup Resistor switched DC (included) OWES power supply. A2143-10 LOOP ADDRESS 0 9 Optional Branch Circuit TO Next Interface Module 6720w r5 Module supervises supply voltage and detector loop. V Fig. 7 FZM-1: Interface two-wire conventional detectors, NFPA Style D. TO Next Device t) FROM Panel (+) or Previous • Device ( INTERFACE Communication Line MODULE S 32 VDC maximum. 0 Twisted-pair is recommended. 3.9K EOL Resistor 8 + (included) required at terminals 8 & 9 7 TENS 2 63 (—) Listed Battery Backup A2143-1O 5 4 OWES + switched DC power supply. LOOP ADDRESS ° ç ç, 9 ...- Optional Branch Circuit TO Next Interface Module 6720wir6.wmf Module supervises supply voltage and detector loop. V Fig. 8 FRM-1: Relay contral module used to disconnect a power supply. TO Next C—) FROM Pane! Device .(+)__ (+) or Previous RELAY Device CONTROL DC POWER SUPPLY (+) d MODULE Listed for Fire (—) Communication Line Protection with 1____ Battery Backup 1 E18 1L J 9 32 VDC maximum. Twisted-pair is 2 J recommended. _______ (—)4 16 3J (+) ( LOOP ADDRESS 09 67201,ir7.wrnf Page 6 of 6 - DN-6720- 11/13/00 CALIFORNIA DEPARTMENT OF FORESTRY & ARE PROTECTION OFFICE OF THE STATE ARE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models FMM-1, FMM-1 01, FZM-1, FSM-1 01, FDM-1 * monitor modules and Models FCM-1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: in accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Rev. 05-02-01 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager S The NBG-I2LX Addressable Manual Pull Station June 9, 2000 DN-6726• N OTIFIER' OTI Fl ER® W FIRE SYSTEMS GENERAL The NOTIFIER NBG-I2LX is a state-of-the-art, dual-ac- tion (i.e., requires two motions to activate the station) pull station that includes an addressable interface fo any NOTIFIER intelligent control panel. Because the NBG- 12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. FEATURES Maintenance personnel can open station without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTI- VATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm' wire). Semi-flush, mounts to a standard single-gang (2.125" [5.3975 cm] minimum depth), double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Within ADA 5 lb. pull force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-1 2LX stations per loop on classic protocol systems (non-FlashScan). Up to 159 NBG-12LX stations per loop on FlashScan protocol systems. Dual-color LED blinks green for FlashScan systems. CONSTRUCTION Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word 'ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; closing the door automati- cally resets the switch. NBG-12LX Addressable Manual Pull Station with FlashScanM Section: Intelligent/Addressable Devices U.S. PATENTS PENDING C (@US California State Fire Marshal 7150-0028:199 LISTED S692 Approved Each manual station, on command from the control panel, sends data to the panel representing thestate of the manual switch. Two rotary decimal switches allow address set- tings (1-159 on FlashScan Systems, 1-99 on CLIP sys- tems). FlashScanTM is a trademark of NOTIFIER. LEXAN@ is a regis-tered trademark of GE Plastics, a subsidiary of General Electric Company. This document is not intended to be used for installation purposes. We try to keep ou r product information up-to-date and accurate. We cannot cover all specific applicati o n s o r anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484.71 1 8 E- - OTI F! £ R 12 Clintoñville Road, Northford, Connecticut 06472 ENGINEERINC & MANUFATURl S S DN-6726• 06/09/00 - Page 1 of 2 PRODUCT LINE INFORMATION Model Description S NBG-12LX Dual-action addressable pull station Includes key locking feature. SB-10 Surface backbox. BG-TR Optional trim ring. INSTALLATION The NBG-I2LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the Model SB-b sur- face backbox. If the NBG-I2LX is being semi-flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). I Terminal I Connections ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 230 pA. ARCHITECTURAL! ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycar- bonate equivalent) with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-b; or semi-flush mount- ing on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual sta- tions shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Detail of TAB 150 0 - I - I SLC (_) 2 SLC Back of station without door. E .1 0 PH HSU9 L I . _ I H ioll_ 3nt 0- : P Cover open to show easy access to miniature monitor module, rotary switch, and UL label. 12 11 q76 FE 1H LED ROTARY DECIMAL SWITCHES *Remove tab to select addresses above 99 (FlashScan systems only). Page 2 012 - DN-6726 • 06/09/00 UALIrUrIMA L)crMruMtr'di or rurtitjy & t'ffit rhUitI.,iIur OFFICE OF THE STATE ARE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of 1 CATEGORY: Manual Pull Stations/Boxes LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 DESIGN: Models NBG-1 2, NBG-1 2S, *NBG1 2LR, *NBG12LRA, NBG-1 2LAO , NBG-1 2LAOB*, NBG12LO*, *NBG12LOB NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG- 12LWP, NBG-1 2L, NBG-1 2LX, NBG-1 2LA, NBG-1 2PS, NBG-1 2LSP and NBG-1 2SP fire alarm pull boxes. The NBG-1 2 series is a dual action pull station that has normally open switch contacts. *Models NBG-1 2LR and NBG-1 2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, .model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-1 2WP, NBG-1 2LW, NBG-1 2W and NBG-1 2LWP are intended for outdoor use when installed with Model WP-1 0 back box. Models NBG-LAOB and NBG-1 2LOB are intended for outdoor use when installed with Model WBB or WP-1 0 back box. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test (J) results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation U._.........JJ criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager September 15, 2000 DN-6716' H-210 FST-751 Series Intelligent Thermal (Heat) Detectors with FlashScan rM Section: Intelligent/Addressable Devices (S GENERAL The FST-751 Series intelligent thermal detector is used with the intelligent NOTIFIER Fire Alarm Systems to mea- sure thermal levels caused by a fire and report the analog level of the thermal measurement to the control panel. The use of analog information provides significant ben- efits to the end user, installer, and service personnel in ways which are not possible with a conventional type sys- tem. Since this detector is addressable, it helps firefighters to more quickly locate a fire in its early stages. FlashScan (patent pending) is a new communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel's CPU stops the group poll and concen- trates on single points. The net effect is response speed greater than five times that of earlier designs. FEATURES Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-751R), 15°F (8.3°C) per minute. Factory preset at 135°F (58°C). Addressable by device. Direct 01 - 159 entry of address (01 - 99 on traditional systems). Two-wire loop connection. Visible LEDs "blink' every time the unit is addressed. 360°-field viewing angle of the visual alarm indicators (Two bicolor. LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type iden- tification. Remote test feature from the panel. Built-in functional test switch activated by external mag- net. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Listed to UL 521. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. •Sealed against back pressure. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. SEMS screws for wiring of the separate base. 94-5V plastic flammability rating. California State Fire ZD 9 7270-0028:196 Approved LISTED MARYLAND (AFC-600) S747 State Fire Marshal Permit 2011 MEA 278-99-E CS630 -....-... % I 6716p501j55 Remote LED output connection to optional RA400Z remote LED annunciator: Optional sounder, relay, and isolator bases. Optional recessed (RMK400) or surface (SMK400) base mounting kits. APPLICATIONS Use thermal detectors for protection of property. For further information call NOTIFIER for manual 56-407- 00, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. CONSTRUCTION. These detectors are constructed of Bayblend® in an off-white color. The FST Series plug-in intelligent thermal detector is de- signed to commercial standards and offers an attractive ap- pearance. INSTALLATION The FST Series plug-in intelligent thermal detector uses a separate base to simplify installation, service, and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on box which is at least 1.5" (38.1 mm) deep. Suitable boxes include: 4° (101.6 mm) square box. FlashScanTM is a trademark of NOTIFIER. Bayblend® is a registered trademark of Bayer Corporation. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For IS09001 more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 .- Mill =1 i N OTI Fl ER° 12 Clintonville Road, Northford, Connecticut 06472 &MANFACTURIN DN-6716 09/15/00 - Page lof 2 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box. Single-gang box (except relay or isolator base). With B50IBH or B50IBHT base, use a 4" (101.6 mm) square box. With B224RB orB224B!base, use a 3-1/2' (88.9 mm) or 4" (101.6 mm) octagonal box, or a 4" (101.6 mm) square box. NOTES: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and iso- lator bases. OPERATION Each FST Series uses one of 159 possible addresses (99 on traditional systems) on a control panel SLC loop. It responds to regular polls from the control panel and it reports its type and status, including the analog level of its heat-sensing elements. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm analog level. It blinks its LEDs when polled and turns the LEDs on when com- manded by the panel (detector blink is optional). The FST Series offers features and performance that represent the latest in thermal detector technology. SPECIFICATIONS Size: Diameter installed in B7IOLP: 6.1" (154.94 mm): Diameter installed in B501: 4.1" (104.14 mm). Height: 1.66" (42.16 mm). Weight: 5 oz. (150 gm). Operating temperature: —4°F to 100°F (-20°C to 38°C). Operating humidity range: 10% to 93% relative humidity, noncondensing. Operating voltage/current range: 15 -28 V (Peak DC), 5 mA current for visible LEDs latched on. Detector standby current: 300 pA @ 24 VDC (one com- munication every 5 seconds with LED blink enabled). For bases B224RB or 8224B1: <700 iA @ 24 VDC (includes detector). Sensor: electronic, dual thermistors. Fixed temperature setpoint: 135°F (57°C). WIRING DIAGRAM REMOTE ANNUNCIATOR Rate-of-rise option: 15°F (8.3°C) per minute. B224RB relay base: Screw terminals: up to 14 AWG (2,00 mm2). Relay type: Form-C. Ratings: 2 A © 30 VDC resis- tive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2" (157.48 mm) diameter x 1.2" (30.48 mm) high. See Note 2 (left column). B224B1 isolator base: Dimensions: 6.2" (157.48 mm) diameter x 1.2" (30.48 mm) high. Maximum: 25 devices between isolator bases. See Note 2 (left column). PRODUCT LINE INFORMATION Model Description FST-751 Intelligent thermal sensor. FST-751R Intelligent thermal sensor with rate-of-rise fea- ture. BASES: B7IOLPBP Standard U.S. style low-profile base, package often (10). B501 BP Standard European flangeless base, pack- age often (10). B50IBH Sounder base, includes 6501 base above. 24 VDC, 85 dBA internal horn. B501BHT Same as B501BH but with temporal pattern. sounder. B224RB Intelligent relay base. B224B1 Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: RA400Z* Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. SMK400 Surface mounting kit provides for entry of sur- face wiring conduit. For use with B501 base only. RMK400 Recessed mounting kit. For use with B501 base only. M02-04-00 Test magnet. Supported by 8501 and B7IOLP base only. ARCHITECTS' & ENGINEERS' SPECIFICATIONS Specifications are available on these and all NOTIFIER prod- ucts. Please contact NOTIFIER. Page 2 of - DN-6716'09/15/00 CALIFORNIA DEPARTMENT OF FORESTRY & ARE PROTECTION OFFICE OF THE STATE ARE MARSHAL ARE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE No. LISTING 1 of 1 7270-0028:196 Page CATEGORY: Heat Detector LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 DESIGN: Models FST-751 (fixed temperature) and FST-751 R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. - RATING: 135° F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Inc. Label .APPROVAL: Listed as heat detectors for use with Model B501 or B71OLP base (CSFM Listing No. 7300-0028:173) and listee's separately listed compatible fire alarm àontrol units. 08-06-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation lk.__...P criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 41 2001 Listing Expires June 30, 2002 Authorized By: BEN IK Supervising Deputy Program Manager GENERAL The NOTIFIER FSP-751 (photo) and FSI-751 (ion) are ana- log, addressable, low-profile (height measures only 1.667 42.164 mm) smoke detectors designed for the entire line of intelligent systems from NOTIFIER. The FSP-751T photo model includes a built-in thermal (heat) detection device. If either condition (smoke or heat) is detected, the device will alarm. The addressability of the FSP-751 and FSl-751 enables the control panel to provide firefighters with a pinpoint descrip- tion of where the fire is located. The FSP-751 and FSI-751 are also analog devices. The control panel is capable of not only knowing the detector's location but exactly how much smoke is in the chamber of the detector. The detector may be set for different sensitivity settings appropriate to the en- vironment of its location. Analog devices continually send obscuration values to the con- trol panel. These values may be gathered so as to allow the control panel to determine if a detector has accumulated an excessive amount of dirt or dust. A "maintenance" required indication allows the installer to clean the smoke detector be- fore an unwanted false alarm occurs. The FSl-751 Intelligent Ionization Sensor incorporates a unique single-source chamber design to respond quickly and dependably to a broad range of fires. The FSP-751 Intelligent Photoelectric Sensor's unique opti- cal sensing chamber is designed with superior signal to noise ratio. The optical chamber is engineered to sense the pres- ence of smoke produced by a wide range of combustion sources. FlashScan® (patent pending) is a new communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelli- gent devices and certain NOTIFIER systems. Intelligent de- vices communicate in a grouped fashion. If one of the de- vices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. FlashScan® is a registered trademark of NOTIFIER. FEATURES Sleek, low-profile design (height only 1.66"/42.164 mm). Common base for both photo and ion detectors. * Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Rotary 01 to 159 address switches (01 to 99 on traditional systems). Optional remote, single-gang LED accessory (RA400Z). Dual LED design provides 360° viewing angle. December 15, 2000 DN-6714 H-200 FSI-751 and FSP-751/751T Low-Profile Intelligent Plug-in Smoke Detectors with FlashSccin® Section: Intelligent/Addressable Devices ,jjjs1 (1California 7272-0028:206 (FSP-751/-751 T) LISTED C5308 7271-0028:201 S1115 (FSI-751) MARYLAND MEA < > State Fire Marshal 27799-E 2020 (Fsl-751) Approved (FSP-7511 2013 (FSP-751/-751T) •751T only) - FSP-751T with B7IOLP base 711 :IL -1 AIti1; i:u - FSP-751 with RMK400 recessed mounting kit Visible bicolor LEDs blink green every time the detector is addressed, and illuminate steady red on alarm. Walk test with address display (an address of 121 will blink the detector LED: 12-(pause)-1) (FlashScan(D systems only). Built-in functional test switch activated by external mag- net. Optional relay, isolator, or sounder bases. Listed to UL 268. SPECIFICATIONS Size: 1.66" (42.16 mm) high x4.1" (104.14 mm) diameter. Shipping weight: 3.6 oz. (104 g). Operating temperature: 0°C to 49°C (32°F to 120°F). ) / I This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or I IS0900-1 I anticipate all requirements. All specifications are subject to change without notice. I I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 I .1 N OTI Fl E R 12 Clintonville Road, Nrthford, Connecticut 06472 ENGINEERING & MANUFACTIIRIC DN-6714 12115/00 - Page 1 of 4 S UL listed velocity range: ION: 0 - 1500 fpm (0 - 7.62 m/ sec). PHOTO: 0 - 4000 fpm (0 - 20.32 mlsec). Relative humidity: 10% - 93% noncondensing. ELECTRICAL SPECIFICATIONS: Voltage range: 15 - 32 volts DC peak. Standby current - ION: 200 pA @ 24 VDC (without com- munication); 300 pA @ 24 VDC (one communication every 5 seconds with LED enabled). Standby current - PHOTO: 250 pA @ 24 VDC (without communication); 360 pA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @ 24 VDC ("ON"). Air velocity ratings: FSP-751 & FSP-751T. to 4,000 ft./min. (1219.2 rn/mm.). FSI-751: to 1,500 ft./min. (457.2 m/min.). BASES AVAILABLE: B7IOLP: 6.1" (154.94 mm) diameter. B501: 4.1' (104.14 mm) diameter. BSOIBH or B50IBHT: Sounder base assembly. Includes B501 base. 8224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm'). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC in- ductive. Dimensions: 6.2" (157.48 mm) x 1.2" (30.48 mm). B524B1 Isolator Base: Dimensions: 6.2" (157.48 mm) x 1.2" (30.48 mm). Maximum: 25 devices between isolator bases. Duct applications: FSP-751 and FSP-751T are Listed for use in air ducts. See Duct Application Guide A05-1004 for details on pendant-mount applications. NOTE: These prod- ucts are NOT Listed for use inside a duct smoke detector housing. INSTALLATION The FSP-751 and FSI-751 plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and re- move detectors without using a ladder. Mount base on a box which is at least 1.5" (38.1 mm) deep. Suitable mounting base boxes include: 4" (101.6 mm) square box. 3-1/2" (88.9 mm) or 4" (101.6 mm) octagonal box. Single-gang box (except relay or isolator base). With B50IBH base, use a 4° (101.6 mm) square box. With B224RB or B224B! base, use a 3-1/2" (88.9 mm) octagonal box, or a 4" (101.6 mm) octagonal or square box. SMOKE GUARD Cover: 16 gauge perforated steel (3/16" [4.7625 mm] dia. perforations on 1/4" [6.35 mm] staggered centers). 51% open. SDG-773 is 3" (76.2 mm) deep by 7" (177.8 mm) wide. Frame: 3/4" x 3/4" (19.05 x 19.05 mm) angle, 14 gauge solid steel. All guards are supplied with the following: Guards fasten to mounting frame with No. 10/24 x 3/8" (9.525 mm) long Allen-head screws (10/24 spanner-head screws and tool option at extra cost). Standard finish: Cool Tan" baked enamel. PRODUCT LINE INFORMATION Model Description FSI-751 Low-profile intelligent ionization sensor. Must be mounted to one of the bases listed below. FSP-751 Low-profile intelligent photoelectronic sensor. Must be mounted to one of the bases listed be- low. FSP-751T Same as FSP-751 but includes a built-in 135°F (57°C) fixed-temperature thermal device. BASES: B7IOLPBP Standard U.S. low-profile base, pkg. of 10. B50IBP Standard European flangeless base, pkg. of 10. B50IBH Sounder base, includes B501 base above. B501 BHT Same as B501 BH, but includes temporal sounder. B224RB Intelligent relay base. B224B1 Intelligent isolator base. Isolates SLC from loop shorts. ACCESSORIES: SDG-773 Smoke Detector Guard. This guard is mechani- cally compatible with both FSi-751 and FSP-751 detectors. It is UL-compatibility listed with the FSP-751 (file UL S5515). It is NOT UL-compat- ibility listed with the FSI-751. FIIO Retrofit replacement flange for BX-501 base. Converts BX-501 base for use with FlashScan detectors. RA400Z* Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. SMK400 Surface mounting kit provides for entry of sur- face wiring conduit. For use with B501 base only. RMK400 Recessed mounting kit. For use with B501 base only. SMB600 Surface mounting kit for use with B7IOLP. M02-04-01 Test magnet. M02-09-00 Test magnet with telescope stick. XR-2 Detector removal tool. Allows installation and/ or removal of FlashScan Series detector heads from base in high ceiling installations. XP-4 Extension pole for XR-2. Comes in three five- foot sections. *Supported and B501 bases by B7IOLP only. OPTIONAL SDG-773 Smoke Guard (1.905 cm) 7" (17.78 cm) 1 - (1.905 cm), 3° (7.62 cm) MOUNTING DIAGRAM SDG-773 Smoke Guard 4762s4gm.wmf -- ceiling -. or Wall MODEL NO. SDG-773 Page 2of4 - DN-6714'12/15/00 CALIFORNIA DEPARTMENT OF FORESTRY & ARE PROTECTION OFFICE OF THE STATE ARE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE C LISTING No. 7272-0028:206 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 DESIGN: Models FSP-751, HPX-751 and FSP-7511 photoelectric type smoke detectors. Model FSP-751T employs a supplemental heat sensor to assist the smoke detector. This heat sensor is not intended for use as a heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751 and FSP-7511 are suitable for open areas with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between. 0-300 fpm. 08-21-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager Series RSS Series RSSP whe.elock (O UI I1 YSTEI MEA FIRE ALARM SYSTEMS Helping People Take Action" ~0' P S PECI FIRETM A Family of Multi-Candela Appliances" SERIES RSS & RSSP SINGLE & MULTI-CANDELA STROBES & STROBE PLATES 0 DESCRIPTION Wheelock's patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw and Zero Inrush while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 15/75cd or Wheelock's patent pending Multi-Candela strobe with field selectable candela settings of: 15, 30, 75 or 110cd. Ceiling mount models are available in 15, 30, 75 or 100cd intensities. All models may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or the PS-12/24-8 Power Supply with Wheelock's Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA72 (1999). Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided fora clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with Wheelock's SBL2 surface backbox. Copyright 2000 Wheelock, Inc. Allrights reserved Multi-Candela Indicator (bottom of Strobe Lens) Features Approvals include: UL 1971, New York City (MEA), California State Fire Marshall (CSFM), Pending: Factory Mutual and Chicago (BFP). ADAINFPA/ANSI compliant. Meets *OSHA 29 Part 1910.165. Wall mount models are available with Field Selectable Candela Settings of 15, 30, 75 or 110 cd. (Multi-Candela models) or 15175cd. Ceiling mount models are available in 15, 30, 75 or 100cd. Low current draw with temperature compensation to reduce power consumption and wiring costs. Strobes produce I flash per second over the regulated voltage range. 12 and 24 VDC models with wide New UL "Regulated Voltage" using filtered (DC) or unfiltered VRMS input voltage. Wall Mount or Ceiling Mount models. Synchronize with Wheelock SM, DSM or PS-12124-8 Power Supply with Wheelock's built-in sync protocol. ZERO Inrush above Peak. Compatible with all Wheelock 2-Wire products. Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire. Table 1: Specifications & Ordering Information - Multi-Candela Models - WALL MOUNT Model Order CodeVoltage Input VDC Regulated Voltage Range VDC/FWR Strobe Candela (CD) Average Current * 15cd 30cd 75cd llOcd Mounting Options ** RSS-24MCW-FR 9400 24 16.0-33.0 15/30175/110 .047 .081 .128 .166 B,D,E,F,G,H,J,N,OR,X RSS-24MCW-FW 9401 24 16.0-33.0 15/30/75/110 .047 .081 .128 .166 B,D,E,F,G,H,JN,OR,X RSSP-24MCW-FR 9402 24 16.0-33.0 15/30175/110 .047 .081 .128 .166 D,E,Z Table 2: Specifications & Ordering Information - Single Candela Models Note: Models are available in & Red or White. Contact Customer Service for Order Code and Delivery. Average Current per actual Wheelock Production Testing a Listed VDC. For Rated Averag and Peak current across UL regulated voltage range for bot Filtered DC and unfiltered VRM see Installation Instructions. Mountino Ontions Model Order Code Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela Average Current * Mounting Options SERIES RSS STROBES -WALL MOUNT RSS-2415W-FR 7470 24 16.0-33.0 15 .051 B,D,E,F,G,H,J,N,O,R,X RSS-241575W-FR 7471 24 16.0-33.0 15 (75 on A)ds) .065 B,D,E,F,G,H,J,N,ORX RSS-2430W-FR 7472 24 16.0-33.0 30 .081 B4OE,F,G.H,J,N,O,R,X RSS-2475W-FR 7473 24 16.0-33.0 75 .133 B,D,E,F,G,H,J,N,O,R,X RSS-24110W-FR 7474 24 16.0-33.0 110 .161 B,DE,F,G,HJ,N,O,R,X RSS-1215W-FR 7475 12 8.0-17.5 15 .123 B,D,E,F,G,H,J,N,O,R,X RSS-121575W-FR 7476 12 8.0-17.5 15 (7'5 on A)is) .170 B,D,E,FG,H,J,N,O,R,X SERIES RSS STROBES - CEILING MOUNT RSS-2415C-FW 7482 24 16.0-33.0 15 .072 B,D,E,F,G,H,J,N,O,R,X RSS-2430C-FW 7483 24 16.0-33.0 30 .102 BDE,FG,H,J,N,O,R,X RSS-2475C-FW 7484 24 16.0-33.0 75 .205 B,D,E,F,G,HJ,N,O,R,X RSS-24100C-FW 7485 24 16.0-33.0 100 .238 BD,E,FG;H,JN,O,R,X SERIESRSSPSTROBEPLATES -WALLMOUNr . RSSP-2415W-FR 7792 24 16.0-33.0 15 .051 D,E,Z RSSP-241575W-FR 7793 24 16.0-33.0 15 (75 on A)is) .065 D,E,Z RSSP-2430W-FR 7794 24 16.0-33.0 30 .081 D,E,Z RSSP-2475W-FR 7795 24 16.0-33.0 75 .133 D,E,Z RSSP-24110W-FR 7796 24 16.0-33.0 110 .161 D,E,Z RSSP-1215W-FR 1 7797 12 8.0-17.5 15 .123 D,E,Z RSSP-121575W-FR 7798 12 8.0-17.5 .170 Refer to Data Sheet S7000 I 15 (75 on Axis) ** D,E,Z or if ther NOTE: All CAUTIONS and WARNINGS are Identified by the symbol A . All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash ( rate of I to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL 1971. Series RSS & RSSP Strobe products are listed under UL 1971 for indoor use with a temperature range of 32° F to 1200 F (00 C to 49° C) and maximum humidity of 85%. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". SYNC MODULES /POWER SUPPLY Average Model Number Order Input voltage Current Mounting Code (VDC) (AMPS) @ Options00 24V0C SM-12124-R' 6369 24 .025 W DSM-12124-R" 6374 24 .038 W PS-12)24-8 " 8114 120 VAC # SM Sync Module is rated for 3.0 amperes @ 24 VDC. ## DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM Modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions (P83123) for SM and P83177 for DSM). :::::: Refer to Data Sheet S9001 or Installation Instructions P83862 for PS-12/24-8 Power Supply. Table 3: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH Motor Bells MB-G6/GI0 Speakers ET-101011080, E70, ET70 Chimes CH70 SERIES RSS/RSSP APPLIANCE NON-SYNCHRONIZED SERIES RSS/RSSP APPLIANCE SYNCHRONIZED W/SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM Wiring Diagrams FROM TO NEXT - PRECEDING APPLIANCE APPLIANCE F OR EOLR ORFACP F I II.) STROBE AH 0. robe Strobe STROBE ________ 0I AC C ircu It I 0- SERIES RSS/RSSP APPLIANCES SYNCHRONIZED W/ DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC • SYNC CIRCUIT g+OIJTI .lN i RSS RSS RSS MINUS I 0+ ]TROBE AUDIBLE MINUS 2 0 0 + IN 2 RSS RSS RSS NAC 0+ OUT 2 CIRCUIT RETURN SERIES RSSIRSSP APPLIANCES SYNCHRONIZED W!MULTIPLE DSM MODULES DSM #1 0 WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83911) SERIES RSS/RSSP-24MCW, (P84022 AND P84025) SERIES RSS/RSSP SINGLE CANDELAAND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALLAPPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL EFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULTIN PROPERTY - DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. TO NEXT FROM APPLIANCE PRECEDING + STROBE/PLATE APPLIANCE OR FACP ASSEMBLY I AUDIBLE & VISIBLE APPLIANCE ' OR EOLR I OPERATE IN UNISON + + + 1r ------ STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE STRO8E APPLIANCE OPERATE INDEPENDENTLY DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP APPLIANCES SYNCHRONIZED W/ PS-12124-8 AS N$S OUTPUTS EOLR F _____ 4-CLASS A 1.4 C P OR 2-CLASS AS Series P5-12124-8 # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions (P83123 for SM and P83177 for DSM). For wiring information on the PS-12/24-8 Power Supply refer to Installation Instructions P83862. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects andEngineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design and shall have Zero Inrush. Where wall mount, Multi-Candela appliances are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL 1971 for: 15, 30, 75 or 110 candela. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15/75 candela strobe shall be specified when 15 candela UL 1971 listing with 75 candela on-axis is required (e.g. ADA compliance). For ceiling mount applications, the strobe intensity shall be 15, 30,75 or 100 candela. When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12/24-8 Power Supply with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single-gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. - NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. Note: Wall and Ceiling Mount Models are Compatible Series RSS Multi-Candela I RSSP Multi-Candela I Series RSS Ceiling Quick Reference Guide Model Order. Code Wall Mount Ceiling Mount Non- Sync Sync wi SM,DSM or PS-12/4-8 Strobe Candela 24 VDC 12 VDC # Model COlor RED # Model Color WHITE RSS-24MCW-FR 9400 X X X 15130175/110 X X RSS-2415W-FR 7470 X X X 15 X X RSS-241575W-FR 7471 X X X 15 (75 on Axis) X X RSS-2430W-FR 7472 X X X 30 X X RSS-2475W-FR 7473 X X X 75 X X RSS.24110W-FR 7474 X X X 110 X X RSS-1215W-FR 7475 X X X 15 X X RSS-121575W-FR 7476 X X X 15 (75 on Axis) X X RSS-2415C.FW 7482 X X X 15 X X RSS-2430C-FW 7483 X X X 30 X X RSS.2475C-FW 7484 X X X 75 X X RSS-24100C-FW 7485 X X X 100 X X RSSP-24MCW-FR 9402 X X X 15/30/75/110 X X RSSP-2415W-FR 7792 X X X 15 X RSSP-241575W-FR 7793 X X X 15 (75 on Axis) X RSSP-2430W-FR 7794 X X X 30 X RSSP-2475W-FR 7795 X X X 75 X RSSP-24110W-FR 7796 X X X 110 X RSSP-1215W-FR 7797 X X X 15 X X RSSP-121575W-FR 7798 X X X 15 (75 on Axis) X X # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION çS NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: Infowheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY Made in USA Member -. istributed By: (:0 WHEELOCK, INC. • 273 BRANCHPORT AVE. LONG BRANCH, N.J. 07740 -732-222-6880 • FAX: 732-222-2588 - S0410 11100 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired L1STEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-8707 DESIGN: Models RS-241 SW, RS-241575W, RSP-241 5W, RSP-241 575W Strobe Light; Models RSS-2415W, RSS-2475W, RSS-241 575W, RSS-2430W, RSS-241 lOW, RSSP-241 5W, RSSP-2475W, RSSP-241 575W, RSSP-2430W, RSSP-241 lOW, RSS-1 215W, RSSP- 1215W, RSS-1 21575W, RSSP-1 21575W, RSS-241 SC, RSSP-241 SC, RSS-2430C, RSSP-2430C, RSS-2475C, RSSP-2475C, RSS-24100C, RSSP-24100C, *RSS24MCW and *RSSP-24MCW synchronized or non-synchronized Strobe Lights. Model number may be followed by any two alpha/numeric characters indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 20-31 VDC/FWR *RSS24MCW RSSP-24MCW: 16-33 VDC/FWR Candela 15=15cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) *Rss24Mcw RSSP-24MCW: Selectable 15cd, 30cd, 75cd or 110cd Flash rate 60 Flashes/minute ONSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models with -w are intended for wall mount only. Models with -C are intended for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only. For synchronization strobes, Models SM-i 2/24, SMX-1 2/24, DSM-1 2/24 or DSMX-1 2/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Rev. 06-05-2000 - This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer tolistee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 24, 2001 Listing Expires June 30, 2002 Authorized By: BEN/JO, Supervising Deputy 40 Program Manager Series PS-12124-8 Power Supply Series PS-12124-8 (Batteries Not Included) Input and output synchronization (including pass through) FACP NAC supervision steered to either input #lor#2 Common input and output trouble circuit Input and output LED indicators AC fail supervision (Form "C" contacts rated @ I amp @24 VDC orI15VAC Battery presence and low battery supervision (Form "C" contacts rated @ I amp @ 24 VDC or 115 VAC Ground fault detection Thermal and short circuit protection with auto reset Built-in battery charger for sealed lead acid or gel type batteries Automatic switch over to stand-by batteries when AC fails Zero voltage drop when switching to battery stand-by• Circuit breaker battery protection Unit includes power supply, red enclosure, cam lock, open frame transformer and battery leads Size: 15.5" H x 12.5" W x 4.5" D wheebc.k TH,CffYOF I1 I') Uo NVYOf MEA FIRE ALARM SYSTEMS Helping People Take Action'" I POWERPATH TM I Descr4otion POWERPATH Series PS-1 2/24-8 is a power limited 8 ampere power supply/charger used to expand the supervised power capability of a Fire Alarm Control Panel (FACP) for Notification Appliance Circuits (NAC) as well as providing auxiliary power to support system accessories. Power Limited refers to the ratings of the output circuits per UL 864 and NFPA 70 (NEC), Article 760. Two (2) Class "A" or Class "B" inputs from an FACP and two (2) dry trigger inputs are provided to direct and deliver regulated and filtered 12 or 24 VDC via four (4) Class "B", two (2) Class "A" or two (2) Class "B" and one (I) Class "A" NAC Circuits. Each Class A" or Class "B" ouput has a maximum rating or two (2) amperes. A single output of four (4) amperes can be achieved by paralleling two (2) Class "B" outputs. POWERPATH Series PS-1 2/24-8 is compatible with all Wheelock's conventional 12 or 24 VDC Life Safety Notification Appliances and with its Patented BUILT-IN SYNCHRONIZED MODE feature, it. can control and operate all of Wheelock's Synchronized Notification Appliances. Additionally, the horn may be silenced while maintaining strobe activation. Features Approvals: UL 864, MEA, C S F M (except PS-121244E) NFPA-72 COMPLIANT Compatible with 12 or 24 VDC FACP 115 VAC @ 60Hz and 1.85 amps input voltage 8 amperes rated supply current @ 12 or 24 VDC Filtered and regulated power supply outputs Field selectable 12 or 24 VDC outputs Each Class "A" or Class "B" output has a maximum rating of two (2) amperes. 50 mA of resettable (internal or remote) auxiliary power Accepts 2 Class "A" or 2 Class "B" NAC circuit inputs Additional activation options are: NC contacts or open collector of a transistor Programmable EOL Resistor Supervised NAC Circuit Outputs (4 Class "B" or 2 Class "A" or 1 Class "A" and 2 Class "B") with a maximum 2 amperes per circuit Class 2 rated power limited outputs 2 Class "B" Outputs may be paralleled for more power on a circuit (Total 4 Amperes on the circuit) 2 Outputs may be paralleled for more power on a circuit (total of 4 amperes on the circuit) Dip switch selectable options Code 3 (Temporal) option Steady output option Built-in Synchronization Mode Copyriht 2000 W/iee/ock, Inc. All nq/its reserved Architects and Engineers Specifications The power supply shall be Wheelock POWERPATH Series PS-2/24-8, or equivalent. The unit shall be a stand alone power supply intended for powering fire alarm notification appliances via its own Notification Appliance Circuit(s) (NAC). The unit shall be UL 864 approved for power limited operation of its outputs and comply with NFPA 70 (NEC), article 760. The power supply shall be listed under UL Standard 864, and have MEA and CSFM approvals. The power supply shall be activated by a standard Notification Appliance Circuit (NAC) from any Fire Alarm Control Panel (FACP) or a"Dry contact" closure. The unit shall be an 8 ampere, 12 or 24 VDC, regulated and filtered, supervised remote power supply/charger. It shall operate over the voltage range of 9 to 30 VDC. The primary application of the unit shall be to expand a fire alarm system capabilities for additional NAC circuits to support ADA requirements and to provide auxiliary power to support system accessories. The power supply shall provide four Class "B", two Class "A", or two Class "B"and one Class "A" NAC circuit(s). The unit shall also supply resettable auxiliary power of not less than 50 mA at 24 VDC. The power supply shall be capable of charger batteries of up to 12 ampere hours per NFPA 72 (1999). Input activation shall be from not less than two NAC circuits or Dry Contact closures. These inputs shall have the capability of being directed to any combination of the four NAC circuit outputs. Each NAC circuit output shall be rated at 2 amperes and shall be programmable to generate a steady or Temporal (Code 3) output and or a synchronized strobe or horn output. The unit shall have the capability of achieving a four ampere NAC circuit output simply by paralleling two of the NAC circuit outputs. The power supply shall provide independent loop supervision for either Class "A" or Class "B' FACP NAC circuits and shall have the capability to "steer" all alarm or trouble conditions to either incoming NAC circuit. The unit shall have common output terminals and common trouble input terminals. The power supply shall be powered from a 115 VAC, 60 Hz source with a current consumption of 1.85 amperes. The unit shall incorporate short circuit protection with auto reset The power supply shall incorporate a built-in battery charger for lead acid or gel type batteries with automatic switchover to battery back up in the event of AC power failure. The charger shall incorporate circuit breaker protection for the batteries and have the ability to1 report low battery and/or no battery condition(s). Stand by current for battery back up shall be 75 mA. The cabinet dimensions shall be 15.5" H x 12.5" W x 4.5" D. WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY .OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS Specifications and Ordering Information Model Number Order Code Input Voltage/Current PS-12/24-8 5114 120 VAC, 60 Hz; 3.2 amps PS-12/24-8E 8218 220 VAC Output NAC Circuits Output Voltage/Current Four (4) Class "B" 12/24 VDC @2 amps per Circuit Two (2) Class "A" or 8 amps maximum available One (1) Class "A" and Two (2) Class"B" Standby Time Input NAC Circuits 24 hours with up to 5 minutes @ 8 amps of alarm 2 NAC Circuits -or- 2 Dry Contact 60 hours with up to 5 minutes @ 8 amps of alarm Standby Current Maximum Loop Resistance 75 mA 100 Ohms NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION S National Sales Office 800-631-2148 Canada 800-397-5777 E-Mail: lnfo@wheelockinc.com http:I/www.wheelockinc.com 3 YEAR WARRANTY Made in USA IMember Distributed By: 273 Branchport Avenue. Long Branch, NJ 07740 0 TEL: 732-222-6880 0 FAX: 732-222-2588 ( ce (S POWERPATH TM Applications The following applications illustrate the use of synchronized appliances powered by POWERPATH. POWERPATH can Qni be used on NAC's with continuously applied voltage. Do not use POWERPATH on coded or interrupted NAC's in which the applied voltage is cycled on and off. POWERPATH can synchronize the Series RSS, RSSP Strobes, the Series NSINS4I NH and AS/AH horn strobes and the Series SL strobes. Note: The Series RSS and SL strobes are also part of other products (e.g. speakers, chimes, multitone, etc.). Each outputof POWERR4TH can be a Sync Circuit to drive audible/ visual, visual, audible or synchronized appliances. Refer to audible and visual notification appliance Data Sheets or Installation Instruction Sheets for additional information. EO LR Basic Line Diagram 1L __ wu • '1 IMBUE] PER] I L4 LIJ I Fii ri rai rai ri ra1 MIM M-11 4-- From or next signaling FACP FACP device From IT'. ToFACPNAC2EOI. NAC 1 NAC 2 To FACP NAC 1 EOL EOL EOL or next signaling device 2.2K 2.21< 2.2 K EOL 2.21< EOL Optional paralleled Class'B output Fi9ure I Class "B" Connections - AUX+ N-E~OTVC _DC I lo- o lull AUX REs" 1A moll F1 Ik 4- A ,t'. it'. A Return To FACP From From NAC 2 FACP FACP NAC1 NAC2 Return To FACP NAC 1 Fiqure2 Class "A" Connections CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0785:149 Page 1 of I CATEGORY: Power Units LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 DESIGN: Model PS-12124-8 Indicating Circuit Power Supply. Unit is a regulated 12 or 24 VDC power supply/charger used for supervision and expanded power driving capability of up to four notification appliance circuits. The unit is intended for use with Altronix's Model E0L22 end-of-line risistor package. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC input, 12 or 24 VDC output, INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as power supply unit for use with separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. NOTE: For fire alarm use, the standby batteries must provide at least 24 hours standby power during power loss. The battery circuit must be fully supervised. XLF: 7315-1335:107 08-30-99 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: APRIL 16, 2001 Listing Expires June 30, 2002 Authorized By: BENHQ Supervising Deputy Program Manager wheebc Yr Th4CflYOF !i I vi : MEA FIRE ALARM SYSTEMS Helping People Take Action'" 1 G SPEL; 1 FIRETM A Family of Multi-Candela Appliances'" SERIES AS SINGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCES SERIES AH AUDIBLES Desc4otion Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with less current draw and Zero Inrush. Strobe options for wall mount models include I 5175cd or Wheelock's patent pending Multi-Candela strobe with field selectable candela settings of: 15, 30, 75 or 110cd. I. S Ceiling mount models are available in 15, 30, 75 or l0Ocd intensities. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. Additionally, the audible may be silenced while maintaining strobe activation on combination Series AS units. All models may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or the PS-12/24-8 Power Supply with Wheelock's Patented Sync Protocol. Synchronization of the continuous horn tone provides the temporal (Code 3) tone as mandated by NFPA-72 (1999) for all audible appliances. This ensures a distinct temporal (Code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized, the temporal sound may overlap and not be distinctive. At the same time, the strobes will also be synchronized. This provides the ability to comply with ADA recommendations concerning photosensitive epilepsy and NFPA standards when installing two or more visual appliances within the field of view. All of this, plus the ability to silence the audible is achievedby usfr'g only 2 WIRES, Copyright 2000 Wheelock Inc. All rights reserved. SERIES AS SERIES AH Multi-Candela Indicator (bottom of lens) Features Approvals include: UL 1971, UL 464, California State Fire Marshall (CSFM), New York City (MEA), Pending: Factory Mutual (FM) and Chicago (BFP). ADA/NFPNANSI Compliant. Wall mount models are available with Field Selectable Candela Settings of 15, 30, 75 or 110cd (Multi-Candela models) or 15175cd. Ceiling mount models are available in 15, 30, 75 or 100cd. Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones. Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate. Strobes produce 1 flash per second over the regulated voltage range. 12 and 24 VDC models with wide New UL Regulated Voltage" using filtered DC or unfiltered VRMS input voltage. Wall Mount or Ceiling Mount models. Synchronize with Wheelock SM, DSM or PS-12124-8 Power Supply with Wheelock's built-in sync protocol. ZERO Inrush above Peak. Compatible with all Wheelock 2-Wire products. Fast, installation with IN I OUT screw terminals using #12 to #18 AWG wires. Table 2: Average Current * (AMPS) for AS-24 MCW Wall Models Average Current-with High dBA Setting (99 dBA) Voltage l5cd 30cd 75cd llocd 16.0 VDC .095 .142 .242 .308 24.0 VDC .088 .120 .174 .224 33.0 VDC .099 .120 .152 .190 Average Current-with Medium dBA Setting (95 dBA 16.0 VOC .081 .128 .225 .296 24.0 VDC .068 .105 .157 .207 33.0 VDC .068 .090 .119 .157 Average Current-with Low dBA Setting (90 dBA) 16.0 VDC .077 .119 .222 294 24.0 VDC .• .00 .090 .142 .200 33.0 VDC .055 .081 .109 .147 Table 3: Average Current ° (AMPS) Series AH-24-RMI & WP VOLTAGE High Medium Low 16.0 voc .035 .020 .014 24.0 voc .041 .024 .017 33.0 VDC .053 .030 .021 SYNC MODULES I POWER SUPPLY Model Number Order Code Input Voltage (VDC) Average Current (AMPS) @ 24 VDC Mounting Options- SM-12124-R' 6369 24 .025 W DSM-12/24-R" 6374 24 .038 W PS-12/24-8 8114 120 VAC #SM Sync Module is rated for 3.0 amperes © 24 VDC. ##DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions (P83123 for SM and P83177 for DSM). Refer to Data Sheet S9001 or Installation Instructions P83862 for P5-12124-8 Power Supply. NOTE: All CAUTIONS andWARNINGS are identified by the symbol A . All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS ANDASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Genera/Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of I to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL 1971. Series AS Strobe products are listed under UL 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 85%. Series AH-24 horns are listed under UL 464 for audible signal appliances (Indoor use only). Series AH-24WP audible appliances are listed under UL 464 for indoor/outdoor use with a temperature range of -31°F to 150°F (-35°C to 66*C) and maximum humidity of 95%. "Regulated Voltage Range" is the newest terminology used by. UL to identify the voltage range. Prior to this change, UL used the terminoloav "Listed Voltaae Ranae". Table 4: dBA Ratings for 12 VDC and 24 VDC Series As/AU 12 and 24 VDC Audible Description Volume Reverberant dBA Per UL 464 @ 10 ft Anechoic dBA @ loft. continuous Horn High 91 99 Medium 88 95 Low 83 90 Code 3 Horn High 87 99 Medium 84 95 Low 79 90 Average Current (AMPS) for Audible Strobe At the 3 Audible Settings @ 16,24,33 & 8,12 and 17.5 VDC Average Current -with High dBA setting (ao dBA) Voltage AS-2415w AS-241575W AS-2430W AS-2475W AS-24110W 16.0 VDC .104 .124 .152 .240 .291 24.0 VDC .087 .102 .120 .177 202 33.0 VDC .090 .100 .119 .152 .183 Voltage AS-1215W A5-121575W 8.0 VDC .303 .408 12.0 VDC .223 .256 17.5 VDC .214 .251 Voltage AS-2415C As-2430c AS-2475C A5-24100C 16.0 VDC .130 .178 .357 A04 24.0 VDC .106 .135 .248 277 33.0 VDC .102 .131 200 .245 Average Current - with Medium dBA Setting (95 dBA) Voltage A5-2415W AS-241575w AS-2430W AS-2475W AS-24110W 16.0 VDC .009 .108 .140 .224 276 24.0 VDC .072 .003 .105 .156 .183 33.0 voc .067 .077 .092 .130 .158 Voltage AS-12I5W AS-121575W 8.0 VDC .251 .354 12.0 VDC .171 .217 17.5 VDC .147 .182 Voltage AS-2415C A5-2430C AS-2475C A5-24100C 16.0 VDC .116 .164 .339 .389 24.0 VDC .091 .120 .226 .256 33.0 VDC .079 .103 .179 217 Average Current -with Low dBA Setting 90 dBA) Voltage AS-2415W AS-241575W AS-24.39W AS-2475W AS-24110W 16.0 VDC .066 .103 .135 .218 .271 24.0 VDC .064 .077 .098 .149 .177 33.0 voc .058 .067 .064 .117 .148 Voltage A5-1215W A5-121575w 8.0 VDC .230 .346 12.0 VDC .156 .194 17.5 VDC .132 .162 Voltage A5-2415C A5-2430C A5-2475C AS-24100C 16.0 VDC .112 .160 .332 .382 24.0 VDC .082 .113 219 252 33.0 VDC .069 .005 .164 .207 Average Current per actual Wheelock Production Testing at listed VDC. For Rated Average and Peak current across UL regulated voltage range for both Filtered DC and unfiltered VRMS, see Installation Instructions. Refer to Data Sheet S7000 for Mounting Options. Table 1: Ratings Per UL 1971 Model Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (cd) AS-24McW-FR 24 16.0-33.0 1530175/110 A5-2415W-FR 24 16.0.33.0 15 A5-241575W-FR 24 16.0-33.0 15 (75 on A)ds) A5-2430W-FR 24 16.0-33.0 30 AS-2475W-FR 24 .16.0-33.0 75 A5-24110W-FR 24 16.0-33.0 110 A5-1215W-FR 12 8.0-17.5 15 AS-121575W-FR 12 8.0-17.5 15(75onA)ds) A5-2415c-FW 24 16.0-33.0 15 As-2430c-Fw 24 16.0-33.0 30 A5-2475c-F1N 24 16.0 - 33.0 . 75 AS-24100c-F1N 24 16.0-33.0 100 1~ 1• WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" (P83947) SERIES AS-24MCW, (P84023 AND P84024) SERIES AS SINGLE CANDELA, (P83519) Soles AH, (P83641) Series AH-WP AND 'GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL EFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT PRECEDING + APPLIANCE - APPLIANCE OR EOLR OR FACP SERIES AS APPLIANCES SYNCHRONIZED WI DSM MODULE CLASS"A" NAC CIRCUIT WI NO AUDIBLE SILENCE FEATURE .DSM STROBE NAC , SYNC CIRCUIT OUT UT 1 IN 1 AS AS AS MINUS 1 ] AUDIBLE MINUS 2 Ø*IN2 AS STROBE NAC OUT 2 CIRCUIT RETURN SERIES AS APPLIANCES SYNCHRONIZED WI SM MODULE SINGLE CLASS "B" NAC CIRCUIT W/ AUDIBLESILENCE FEATURE SM * STROBE F A - STROBE Strobe 0-- AS Circuit C Audi ble Audible EOLR AudIble NAC Circuit SERIES AS APPLIANCES SYNCHRONIZED W/ MULTIPLE DSM MODULES Audiblele NAC Cir. DSM #1 Strobe NAC Cir. LSSyncf F I NACCI r Aud,be I I DSM #2 A Strobe NAC ci: __AS J C Audible NAC CII I DSM #3 P no r TI11L. SI obe NAC CIr.L. S AS DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES AS & RSS APPLIANCES SYNCHRONIZED W/ PS-12-24-8 F OUTPUTS EOLR .4 4-CLASS H 2-CLASS C 'A' IM P I I OR 50,10, PS-12124-0 # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions (P83123 for SM and P83177 for DSM). For wiring information on the P5-12/24-8 Power Supply refer to Installation Instructions P83862. S Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendicesand amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible Strobe shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). The audible/strobe shall be listed for indoor use and both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design and shall have Zero Inrush. Where wall mount, Multi-Candela appliances are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL 1971 for: 15, 30, 75 or 110 candela. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15/75 candela strobe shall be specified when 15 candela UL 1971 listing with 75 candela on-axis is required (e.g. ADA compliance). For ceiling mount applications, the strobe intensity shall be 15, 30, 75 or 100 candela. When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12124-8 Power Supply with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. -- Note: Wall and Ceiling Models are Compatible Series AS I Series AH Quick Reference Guide Model Order Code Strobe Ôandela VDC AS-24MCW-FR Non-Sync Sync w!SM, DSM or PS-12/24-8 24 VDC 12 Wall Mount Ceiling Mount Mounting Options 9024 151301751110 X X - X A,B,D,E,F,G,H,J,O,R,S,X AS-24MCW-FW 9025 15/30/75/110 X X x - X A,B,D,E,F,G,H,J,O,R,S,X AS-2415W-FR 7404 15 X X X X A,B,D,E,F,G,H,J,O,R,S,X AS-241575W-FR 7405 15 (75 on Axis) X X X - X A,B,D,E,F,G,H,J,O,R,S,X AS-2430W-FR 7406 30 X X X - X A,B,D,E,F,G,H,J,O,R,S,X AS-2475W-FR 7407 75 X X X X A,B,D,E,F,G,H,J,O,R,SX AS-24110W-FR 7408 110 X X X - X A,B,D,E,F,G,H,.J,O,R,S,X AS-1215W-FR 7409 15 X X X X AB,D,E,F,G,H,J,O,R,S,X AS-121575W-FR 7410 15 (75 on Axis) X X - X X A,B,D,E,F,G,H,J,O,R,S,X AS24I5CFW 7411 15 X X X - X A,B;D,E,F,G,H,J,O,R,S,X AS-2430C-FW 7412 30 X X X X A,B,D,E,F,G,H,J,O,R,S,X AS-2475C-FW 7413 75 X X X - X A,B,D,E,F,G,H,J,O,R,S,X AS-24100C-FW 7414 100 X X X - X A,B,D,E,F,G,H,J,O,R,S,X ASWP-2475W-FR 9012 75 X X X - X I (see Data Sheet S5007) AH-24 -R 7892 X X X X X A,B,D,E,F,G,KJ,O,R,S,X AH-12-R 7891 X X X X X A,B,D,E,F,G,H,J,O,R,S,X AH-24WP-R 7416 X X X X X K AH-I2WP-R 7415 X X X X X K *Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION (S NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: lnfo@wheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY Made in USA NEM4 Distributed By: (S WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 '732-222-6880 • FAX: 732-222-2588 S810012/00 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-8707 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1 215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and - 24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. 1. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by a6 alpha or is numeric character indicating product color. Model *As..24MCw audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model *Aswp2475w audible with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2575W is also suitable for outdoor use. RATING: Electrical AS-12: 10.5-15.6 VDC/Vrnis; AS-24: 20-31 VDC(18-3iVrms); AH-12: 9-15.6 VDC/Vrms; AH-24: 18-31 VDC/Vrms, *AS24Mcw *ASWP2475W: 16-33 VDC Candela 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd,100:100cd, 110:110cd *A524M0W: Selectable 15cd, 30cd, 75cd, 110cd *Rev. 10.16-2000 I Listing No. 7125-0785:131 Page 2 of 2 a INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Units without suffix -W or-C are suitable for wall or ceiling mount except Models AS-121575, AS-241575, ASWP2475W* and AS24MCW* are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-1 2WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-i 2/24, SMX-12/24, DSM.12/24 or DSMX-12/24 sync control module (CSFM Listing No. 1300- 0785:132). These appliances can produce a distinctive three pulse Temporal Pattern fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1996 edition. NOTE: Models *ASwp2475w AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 10-16-2000 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test 1 results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 24, 2001 Listing Expires June 30, 2002 Authorized By: BEN HO, Supervising Deputy Program Manager 0 PAGE MI Series 1761 0 hM Fire Protective Underwriters i U i Laboratories Inc.® Listed Type FPLP C U For use in accordance with Article 760, Sections A & C, and with Article 725, Class 2 & 3 circuits for floor warden and fire control stations, smoke detection, voice communications, supervisory and all associated systems. Ii Fully Color Coded 60°C 7161-0972-100. plenum approved PVC U Color Code see Table V. insulation. U Manufactured in accordance U Solid bare copper conductors. with UL Subject 1424 and U 60'C plenum rated PVC the National Electric Code, jacket. Article 760 Sections 760-51(d) & 760-53(a). .S U State of California State Fire Marshall approval number 1761-22-1-41 4 .129 16 .[761-22-1-6J 6 .147 21 1761-22-1-8J 8 .166 27 1761-22-1-10J 10 .184 33 11761-22-1-12J 12 .200 28 1761-22-1-16J 16 .237 51 H:LWIeII I1'I.! :1!; 47 I 'Ph 1 I 1761-18-1-2J 2 .141 32 1761-18-14J. 4 .165 49 1761-1871-6J 6 .211 69 1761-18-1-8J 8 .255 101 LATALOG NUMBER NUMBER OF COND S NOMINAL • 0 D WEIGHT LBS!MFT #16 AWG SOLID CABLED AND JACKETED 1761-16-1-21 -4- 1761-16-1-61 #14 AWG SOLID CABLED AND JACKETED EBB #12 AWG SOLID CABLED AND JACKETED BP-w5q10 00- 10 EIUEIS WIRE & CABLE CORP. 133 South Van Norman Rd. • Montebello, CA 90640 • (800) 423-4659 • (800) 352-4335 (CA) • Fax (562) 692-9203 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING APPROVAL: 7161-0972:100 Page 1 of I Cables-Fire Protective Signaling Atlas Wire & Cable, 133 S. Van Norman Rd., Montebello CA 90640 Contact: Tony Sanders (213) 723-2401 Model FPL, FLPR and FPLP power limited fire protective signaling cables. Conductors: Two or more conductors Insulation: Solid SRPVC, North America Plastics, Grade "NORPLAS" 21570 and/or Gitto/Global Corp, garde GA-8705-03P, Synergistics, Grade 1360-1021-PID. Shield: Polyester film bonded to a aluminum foil; serving, wrap or braid of aluminum wire or of metal-coated or uncoated copper wire (optional). Jacket: PVC, North American Plastics, Grade 'NORPLAS" 882A or Gitto/Global Corp., Grade GA-8705-03, or Senergistics, Grade 1690-1060 PJD. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. Listees name, Type "FPL", "FPLR", "FPLP', and UL label. .Listed as power-limited fire protective signaling cables. Rev. 04-29-97 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: APRIL 30, 2001 Listing Expires June 30, 2002 PAGE Series 202 Fire Protective ©Listed Type CMR-FPLR C® Underwriters Laboratories Inc.® U Solid 0 ttc Lupptl LunduLLJr J ldoiui i Stt nL \'l usi t1 ppio Number 7161 0972 100 U 60 C PVC insulation. ' U Manufactured in accordance with UL Subject U Color Code see Table V. 1424 and the, N.E.C.Article 760 Sections 760-51(f) & 760-53(c). 71 r 2t)2-22 1 i 16 Red 2u-22-1 01 21 I - 27 = .' Red 202 22 1 J 33 . - Red . Red )()2-2 -)-1 i0 20211-LI J2_ 1'. . 1 1 -- 39=. 1Red 202-22-L101 202-11-1-201 - 0 Red 3 6624: Red 17 Black, Red 202-18-1-4) - 30 -, Black, Red, White 202-18-1-01 3-1 Red, White 218-1SJ- - 55 s',-: Red 202-18-1-10 68. -: '-. Red 202-184-1 21 - 202-1-1-101 . . 80 Red 16 - -1O5 -. Red L202-Ioi-2J., - .132 •'- 24 Red :2o2-10 l-1j- 212 ; 43 '3 Red 202li 1 21 20244-1-41 . .308 35 -" Red .350 - -5 '' Red -. _32 :57. Red NON-CABLED APPLICATIONS, ORDER 205 SERIES. L.7 7,77,71r HIii' x• I11 [.JjrJ 3 . ' 133 South Van Norman Rd. • Montebello, CA 90640 • (800) 423-4659 • (800) 352-4335 (CA) • Fax (562) 692-9203 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: 7161-0972:100 Page 1 of 1 CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING APPROVAL: Cables-Fire Protective Signaling Atlas Wire & Cable, 133 S. Van Norman Rd., Montebello CA 90640 Contact: Tony Sanders (213) 723-2401 Model FPL, FLPR and FPLP power limited fire protective signaling cables. Conductors: Two or more conductors Insulation: Solid SRPVC, North America Plastics, Grade "NORPLAS" 21570 and/or Gitto/Global Corp, garde GA-8705-03P, Synergistics, Grade 1360-1021-PID. Shield: Polyester film bonded to a aluminum foil; serving, wrap or braid of aluminum wire or of metal-coated or uncoated copper wire (optional). Jacket: PVC, North American Plastics, Grade "NORPLAS' 882A or Gifto/Global Corp., Grade GA-8705-03, or Senergistics, Grade 1690-1060 PJD. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. Listee's name, Type "FPL", "FPLR", "FPLP", and UL label. Listed as power-limited fire protective signaling cables. *Rev. 04-29-97 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: APRIL 30 2001 Listing Expires June 30, 2002