Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1890 RUTHERFORD RD; ; FA040042; Permit
10/27/21, 10:18 AM FA040042 Permit Data City of Carlsbad Fire Alarm Permit 1890 RUTHERFORD Job Address: RD Permit Type: FALARM Parcel No: 2121203500 Lot #: 0 Permit No: FA040042 Status: ISSUED Applied 6/9/2004 Approved: 6/25/2004 Reference No.: Issued: 6/25/2004 PC #: Inspector: Project Title: ISIS FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: PDG CARLSBAD 47&48 L P 4330 LA JOLLA VILLAGE DR #110 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 90 0 90 0 1/1 '0~0 wc'?, 3 5 FAo400A2, AFIFV1 EHUIERPROE8 FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS ISIS PHARMACEUTICALS TIGER TEST LAB 1980 RUTHERFORD RD. CARLSBAD, CA 92008 FIRE ALARM SYSTEM ISIS PHARMACEUTICALS TIGER TEST LAB 1980 RUTHERFORD RD. CARLSBAD, CA 92008 FIRE ALARM BILL OF MATERIALS NOTIFIeR. F5F-85 I 5MOIf DETECTOR W/571 OLF DASC CSFM# 7272-0028:20G CSFM# 7300-0028:173 NOTIFICR. F5D-75 I Ri' DUCT DCTCCOR. CSFM#: 3240-0028:205 SYSTEM SCNSOR RT545 I REMOTE TEST STATION CSFM# 7300-1209:129 March 3, 2004 DN-6935 • H-202 FSP-851 and FSP-851T NOTIFIER Intelligent Plug-in Photoelectric Smoke Detectors with FlashScan® Section: Intelligent/Addressable Devices GENERAL NOTIFIER 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conven- tional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with decade address switches, providing ex- act detector locations for selective maintenance when cham- ber contamination reaches an unacceptable level. The FSP- 851 photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP-851T. FSP-851 and FSP-851T detectors are compatible with all NOTIFIER intelligent Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices com- municate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. FEATURES Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. FlashScan® (NFS-640, NFS-3030, AFC-600) and classic CLIP system (AFP-1 00, AFP-200, AFP-300, AFP-400, AFC-600, NFS- 640, AFP10I0, AM2020, and NFS-3030) compatible. Rotary, decimal addressing (1 - 99 on current classic sys- tems, I - 159 on FlashScan® systems). Optional remote, single-gang LED accessory (RA400Z). Dual LED design provides 360° viewing angle. Visible bicolor LEDs blink green every time the detector is addressed, and illuminate steady red on alarm. Remote test feature from the panel. ° Walk test with address display (an address of 121 will blink the detector LED: 12-(pause)-1) (FlashScan® systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white Bayblend®, designed to commer- cial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, or sounder bases. Listed to UL 268. Backward-compatible. SPECIFICATIONS Size: 2.1" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in B501 base, 6.1" (15.5 cm) diameter installed in B71OLP base. Shipping weight: 5.2 oz. (147 g). &MEA < 225-02-E LISTED C5915 APPROVED S1115 FSP-851TA) ,' .- State Fire Marshal (FSP851A, California MARYLAND State Fire Marshal 7272-0028:206 Permit# 2122 BSMI U.S. Coast Guard C1313066760036 161.002/23/3 (AFP-200) 161.002/27/3 (AFPI0I0/AM2020) 161.002/42/1 (NFS-640) 03/60011 4 / - -. 6934ph01 pg -- - V FSP-851 with - B7IOLP base ' 6935pho1.Jpg FSP-851T with .-- B7IOLP base Operating temperature: FSP-851: 0°C to 49°C (32°F to 120°F); FSP-851T 0°C to 38°C (32°F to 100°F). Low-temperature sig- nal for FSP-851T at 45°F +/— 10°F (7.22°C +1— 5.54°C). UL-Listed velocity range: 0 —4000 ft/mm. (1219.2 rn/mm.), suitable for installation in ducts. Relative humidity: 10% - 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING and APPLICATIONS: NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceilings, space detectors 30 feet (9.144 m) for ceiling heights 10 feet (3.048 m) and higher. For specific information regarding detector spacing, placement, and special applications, refer to NFPA 72. System Smoke DetectorAppllcation Guide, document A05-1003, is avail- able at systemsensor.com. FSP-851 and FSP-851T are Listed for use in ducts, but they are NOT Listed for use inside duct smoke detector housings. See Duct Application Smoke Detectors Guide, document A05- 1004, available at systemsensor.com, for details on pendant- mount applications. FlashScan® is a registered trademark of NOTIFIER. Bayblend® is a registered trademark of Bayer Corporation. NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. b I I .1 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ENGINEERING I IWIPIUFACiliRING NOTI Fl E R° 12 Clintonville Road, Northiord, Connecticut 06472 QUALITY SYSTEMS DN-6935 • 03/03/04 - Page 1 of 2 ELECTRICAL SPECIFICATIONS: Voltage range: 15 -32 volts DC peak. Standby current (max. avg.): 250 pA @ 24 VDC (with no com- munication enabled); 360 pA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @24 VDC (ON"). BASES AVAILABLE: B7IOLP: 6.1" (15.5 cm) diameter. B501: 4.1" (10.4 cm) diameter. B50IBH orB5O1BHT. Sounder base assembly. Includes B501 base. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm'). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resis- tive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). B224B1 Isolator Base: Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). Maximum: 25 devices between isolator bases. INSTALLATION FSP-851 plug-in detectors use a separate base to simplify in- stallation, service, and maintenance.A special tool allows main- tenance personnel to plug in and remove detectors without us- ing a ladder. Mount base on an electrical backbox which is at least 1.5" (3.81 cm) deep. Suitable mounting base boxes include: 4.0' (10.16 cm) square box. 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. Single-gang box (except relay or isolator base). With B50IBH or B50IBHT base, use a 4.0" (10.16 cm) square box. With B224RB orB224Bl base, use a 3.5(8.89cm) octago- nal box, or a 4.0" (10.16 cm) octagonal or square box. NOTES: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolator modules and isola- tor bases. PRODUCT LINE INFORMATION NOTE: "A" suffix indicates ULC Listed model. FSP-851: Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A: Same as FSP-851 but with ULC Listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-8511A: Same as FSP-8511 but with ULC Listing. Bases: B7IOLPBP: Standard U.S. low-profile base, pkg. of 10. B7IOLPA: Standard U.S. low-profile base, ULC Listing. B501 BP: Standard European flangeless base, pkg. of 10. B50IA: Standard European flangeless base, ULC Listing. B501 BH(A): Sounder base, includes B501(A) base above. B50IBHT(A): Same as B501BH(A), but includes temporal sounder. B224RB(A): Intelligent relay base. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. Accessories: FIIO: Retrofit replacement flange for BX-501 base. Converts BX-501 base for use with FlashScan® detectors. RA400Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. Supported by B7I0LP(A) and B501(A) bases only. SMK400: Surface mounting kit provides for entry of surface wiring conduit. For use with B501(A) base only. RMK400: Recessed mounting kit. For use with B501(A) base only. SMB600: Surface mounting kit for use with B71OLP(A). BCK-200B: Black detector covers, box of 10. M02-04-01: Test magnet. M02-09-00: Test magnet with telescope stick. XR213: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. T55-127-000: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-ft. sections. Defector Guards: NOTE: Some guards listed below may not be applicable to FSP models. SDG-773: Smoke detector guard; cover is 7.0" (17.78 cm) square x 3.0(7.62 cm) deep. This guard is mechanically com- patible with FSP-751. It is UL-compatibility listed with the FSP- 851 (file UL S5515). STI 9601: Low-profile, flush-mount smoke detector guard, wire.* STI 9602: Low-profile, surface-mount, smoke detector guard, wire.* STI 9609: High-profile, flush-mount, smoke detector guard, wire.* STI 9605: High-profile, surface-mount, smoke detector guard, wire.* STI 9604: Flush-mount heat detector guard, wire.* STI 9610: Surface-mount heat detector guard, wire.* *For dimensions and additional information on STI Steel Web Stop- pers, see data sheet DN-4936. STI-8200-SS: Flush-mount stainless steel smoke detector guard (compatibility pending). STI-8230-SS: Surface-mount stainless steel smoke detector guard (compatibility pending). 6833add,.wmf address dial on back of detector Page 2 of 2 - DN-6935 . 03/03/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:206 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models FSP-751, HPX-751, FSP-751T, *F5H751*(1)FAPT751 *FAPT..851 *FSP..851 and *FSP851T photoelectric type smoke detectors. Models FSP-751T and *FSP..851T employ a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. *Models FSP-751, FSP-751T, *FAPT..751 *FAPT851 *FSP 851 and *Fsp..851T Models FSP-751 and FSP-751T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. *Model FSH-751 is suitable for open areas with air velocity between 0-400 fpm. NOTE: 1.(')Combined with 7272-0028:208 2. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 07-24-2002 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 81 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:173 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models BX501, B6IOLP, B612LP, B614LP, B6I6LP and B7IOLP detector bases. Refer to listees data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, product designation, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. XLF: 7300-1209:128 07-29-94 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or : recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 6, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. AREND, Senior Deputy Program Manager (a NOTIFIER® June 5, 2001 DN-6821 • H-215 FSD-751 P and FSD-751 RP Intelligent Photoelectric Duct Smoke Detectors with FlashScan® Section: Intelligent Addressable Devices GENERAL An HVAC system supplies conditioned air to virtually every area of a building. Smoke introduced into this air duct system is thus distributed to the entire building. Smoke detectors for use in air duct systems sense the presence of smoke in the duct. The FSD-751 Pair duct smoke detector is a photoelectric detector, combining this detection technology with an efficient housing design that samples air passing through the duct, allowing detec- tion of a developing hazardous condition. When sufficient smoke is sensed, an alarm signal is initiated at the fire control panel monitoring the detector, and appropriate action can be taken to shut off fans and blowers and change over air handling sys- tems, etc. This can isolate toxic smoke and fire gases or prevent their distribution throughout the areas served by the duct system. Two LEDs on each detector can be programmed by the system control panel to provide a local alarm indication. A remote alarm output is provided for use with auxiliary devices. The FSD-751 P has remote test capability with the RTS451/RTS45I KEY Remote Test Station. Traditional panels support addresses of 0-99. The FlashScan® protocol supports addresses of 0— 159. Patented FlashScan® is a new communication protocol developed by NOTIFIER Engi- neering that greatly enhances the speed of communication be- tween analog intelligent devices. Intelligent devices communi- cate in a grouped fashion. If one of the devices within the group has new information, the panel stops the group poll and concen- trates on single points. The net effect is response speed greater than five times that of earlier designs. APPLICATIONS Duct smoke detectors have specific limitations. Duct smoke detectors are: NOT substitute for open area smoke detectors NOTa substitute for early warning detection. NOT replacement fora building's regular fire detection sys- tem. Call NOTIFIER for a copy of System Sensor's application guide, Proper Use of Smoke Detectors in Duct Applications, (A05- 1004-00). INSTALLATION Wiring: For signal wiring (the wiring between detectors or from detectors to auxiliary devices), it is recommended that single conductor wire be no smaller than 18AWG (0.75 mm2). The duct smoke detector terminals accommodate wire sizes up to 12 AWG (3.25 mm2). Flexible conduit is recommended for the last foot (30.48 cm) of conduit; solid conduit connections may be used if desired. Smoke detectors and alarm system control panels have specifi- cations for Signaling Line Circuit (SLC) wiring. Consult the con- trol panel specifications for wiring requirements before wiring the detector loop. The FSD-751 P/FSD-751 RP detector is de- signed for ease of wiring; the housing provides a terminal strip with clamping plates. LED Features: If programmed with the system control panel, two LEDs on each duct smoke detector light to provide MEA$ 143-00-E (FSD-751P) Q-flfl-F A__1 LISTED CS308 (FSD-751RP) - S1115 (FSD-751PA, FSD-751RPA) MARYLAND California State Fire Marshal State Fire Permit #2036 (FSD-751P) n7' Marshal Permit #2060 (FSD-751RP) 3240-0028:205 local visible indication. Remote LED annunciator capability is avail- able as an option. Each duct smoke detector can only be wired to one remote accessory. NOTIFIER panels offer different feature sets across different panel models. As a result, certain features of the FSD-751 P1 FSD-751 RP may be available on some control panels, but not on others. Possible features, if supported by the control panel are: Panel controls the LED operation on sensor. Operational modes are: RED blink, RED continuous, GREEN blink, GREEN continu- ous, and OFF. SPECIFICATIONS FSD-751 P Operating voltage range: 15 to 32 VDC. Standby current: 300 pA @24 VDC (one communication every 5 seconds with LED blink enabled). Operating temperature range: 32° to 131°F (0° to 55°C). Humidity range: 10% to 93% (non-condensing). Duct air velocity: 500 to 4,000 feet/min. (152.4 to 1219.2 meters/ mm.). Dimensions: 14.375" (365.125 mm) wide x 5.500" (13.970 mm) high x 2.750" (69.850 mm) deep. Options: RTS-451, RTS-451 KEY, RA400Z. Separate auxiliary power not required. FSD-751 RP Operating voltage range: 15 to 32 VDC (comm. line voltage) and 24 VACNDC or 120/240 VAC auxiliary power* (separate source). *NOTE: The FSD-751RP requires a separate auxil- iary source. Standby current: 300 pA @24 VDC (one communication every 5 seconds with LED blink enabled). Auxiliary power current draw (@ 24 VDC): 26 mA (standby), 87 mA (alarm). Options: RTS-451, RTS-451 KEY, RA400Z, APA451. FlashScan® is a registered trademark of NOTIFIER. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 E"-7—=T—Zwgnr3rrqm N OTI Fl E R° 12 Clintonville Road, Northford, Connecticut 06472 ENINEERlNG & MANUFACTURING DN-6821 • 06/05/01 - Page 1 of 2 Operating temperature range: 32° to 131°F (00 to 55°C). Humidity range: 10% to 93% (non-condensing). Duct air velocity: 500 to 4,000 feet/mm. (152.4 to 1219.2 meters! mm.). Dimensions: 14.375(365.125mm) wide x5.500" (13.970 mm) high x 2.750° (69.850 mm) deep. Relay contact ratings: 2 Form-C, DPDT, 10 A @250 VAC, 10 A @30 VDC (resistive). Minimum switching current of 100 mA @ 5VDC. Programming specifications/requirements for intelligent system control panels: The number of devices that can have their LEDs programmed to illuminate is limited by the features of the panel and the individual devices. The actual number of devices is determined by the control panel and its ability to supply LED current. Refer to the control panel installation manual for details. INLET TUBE SELECTION Outside Duct Width Inlet Tube* Up to 2 feet (0.6096 m) ST-1.5 2 to 4 feet (0.6096 to 1.2192 m) ST-3 4 to 8 feet (1.2192 to 2.4384 m) ST-5 8 to 12 feet (2.4384 to 3.6576 m) ST-10 *NOTE: Inlet tube is required and must be purchased separately. Order one inlet tube for each duct smoke detector ordered. PRODUCT LINE INFORMATION Model Description FSD-751 P Duct detector housing with FlashScan® photoelec- tric smoke detector. FSD-751 RP Duct detector housing with FlashScan® photoelec- tric smoke detector, DPDT relay. ST-1.5 Metal sampling tube, duct widths 1' to 2' (see table at left for metric lengths). ST-3 Metal sampling tube, duct widths 2' to 4'. ST-5 Metal sampling tube, duct widths 4 to 8'. ST-1 0 Metal sampling tube, duct widths 8' to 12'. RA400Z Remote annunciator alarm LED. RTS45I Remote test station. Mounts in single-gang box. Includes red alarm LED and magnet test switch. RTS45I KEY Key-activated remote test station. F36-09-00 Replacement filters. M02-04-00 Replacement test magnet. S08-39-01 Replacement photo insect screen. P48-55-00 Replacement end cap for plastic sampling tube. P48-21-00 Replacement end cap for metal sampling tube. A5053FS Replacement photoelectric sensor board. A5067 Replacement power board (without relay). A5060 Replacement power board (with relay). SAMPLE WIRING DIAGRAMS z r. 0 2 2 FSD-751P Detector Terminals See product Installation Intructions for wiring diagrams for the FSD-751 RP. + I i.L" .iii 2nd Detector in Loop FSD-751P Duct Smoke Detector using a UL Listed control panel 682 lwi,2.wn,I I FSD-751P Duct Smoke Detector with optional RA400Z The RA400Z 7 wwwo"'l fo""7 U COMMUNICATION LINE UL Listed Control Panel >- 0 T '2 LU < -0 00 I—W O C) C) 682 lwir3.wmf COMMON TEST 42 C5 ) \ Field-Installed \ JUMPER -CiD® LED j RESET RTS451/RTS451 KEY 4 FSD-751P Duct Smoke Detector with RTS45I/ RTS45I KEY NOTE: For RTS45I, Terminal 3 is not used. RTS451 does not have a Terminal 6. For RTS45IKEY, Ter- minals 3 and 6 are not used. The RTS45I Ow The RTS45IKEY FSD-751 P Detector Terminals Page 2 of 2 - DN-6821 06/05/01 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0028:205 Page 1 of 1 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 Fax (203) 282-7309 DESIGN: Models FSD-751 P, -751 PL, -751 RP, and -751 RPL duct smoke detectors. Units consist of an enclosure, electrical components, sampling and exhaust tubes, and listed photoelectric smoke detector sensor. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15 to 32 VDC INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical and air velocity rating and UL label. APPROVAL: Listed as duct smoke detectors for use with separately listed compatible fire alarm control units. *Models FSD-751PL and -751 RPL are suitable for use in ducts where air velocity varies between 100 and 4000 fpm. *Models FSD-751P and -751 RP are suitable for use in ducts where air velocity varies between 500 and 4000 fpm. Refer to listee's Installation Instruction Manual for details. *Corrected 12-03-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: DECEMBER 3, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. AREND, Senior Deputy Program Manager INSTALLATION AND MAINTENANCE INSTRUCTIONS RTS451 Remote Test Station SYSTEM SENSOR® 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 Specifications Dimensions: 4.6" h x 2.75" w x 1.5" d Weight: .11 lbs. Power Requirements: Alarm LED: 2.8 - 32 VDC, 10 mA max. Total Current: 105 mA max. Test Switch: 10 VA @ 32 VDC Reset Switch: 10 VA @ 32 VDC Alarm Response Time: 40 sec. max. Temperature: -10°C to 60°C (14°F to 140°F) Humidity: 95% RH Non-condensing NOTICE: This manual shall be left with the owner/user of Figure 1. RTS451 Remote Test Station this equipment. NOTE: A test coil is required only for use with DH400/ DH500 models and requires ordering of part #COIL. General Information System Sensor's RTS451 is an automatic fire detector accessory designed to test a remotely located detector. Consult detector installation instructions for additional information. The National Fire Protection Association has published codes, standards, and recommended practices for the installation and use of the above product. It is recommend- ed that the installer be familiar with these requirements, with local codes, and any special requirements of the local authority having jurisdiction. RTS451 Contents 1 RTS451 remote test station 1 #4 screw for mounting bracket 1 screw pack (2 mounting screws) 1 M02-04 test magnet Wiring of RTS451 Consult the appropriate detector installation instructions for the applicable wiring diagram. The RTS451 mounts to a single gang box (21/2" minimum depth), or directly to the wall or ceiling. M02-04 TEST MAGNET LOCATIONS H0196-OO See Figure 2 for wiring diagram of RTS451 with DH100ACDC Duct Smoke Detector. In Canadian applications, the RTS451 is intended to be located in the same room as the smoke detector and within 60 feet of the unit. D440-01-00 11 156-469-07 Operation Test Function Place and hold the painted side of the magnet to the RTS451 on the right or left side of the LED as indicated in the diagram above. Reset Function Gently insert a /8 maximum diameter tool into the hole until it stops and LED turns off. The RTS451 is capable of resetting only certain System Sensor models of detectors. Refer to detector installation instructions for additional information. Alarm Indication With the magnet in place some time will elapse (40 sec. maximum) depending on the detector type, before the alarm indicating LED will light. Figure 2: wiring diagram for RTS451 to DHIOOACDC Figure 3: wiring diagram for RTS451 to DH100 Duct Smoke Detector Duct Smoke Detector DH100ACDC RTS451 DH100 RTS451 KEY Alarm Signal + (3- (Red LED) Alarm Test + Test Aux. Power - Test/Reset - r 4 Reset+ Reset Reset Rp, + LED Reset Field L Installed RA - Test (;i)• Jumper (') Test V Out + No Connection H0197-00 H0198-01 Three-Year Limited Warranty System Sensor warrants its enclosed remote test station to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for this remote test station. No agent, representa- tive, dealer, or employee of the company has the authority to increase or alter the obligations or limitations of this Warranty. The Company's obligation of this Warranty shall be limited to the repair or replacement of any part of the remote test station which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor's toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Repair Department, RA #, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units which are found to be defective because of damage, unrea- sonable use, modifications, or alterations occurring after the date of manu- facture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the company's negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. D440-01-00 2 156-469-07 ©2003 System Sensor CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1209:129 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: System Sensor, 3825 Ohio Ave., St. Charles IL 60174 Contact: *Trish Linhart (630) 377-6674 Fax (630) 377-7245 DESIGN: Models RTS451 and RTS451 KEY remote test switches, and Model RTC remote test station kit. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as accessory devices for use with separately listed compatible duct smoke detectors. NOTE: Formerly 7300-0087:129 Rev. 06-16-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation tL.JJ criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 16, 2003 Listing Expires June 30, 2004 Authorized By: DIANE K. A REND, Senior Deputy Program Manager