Loading...
HomeMy WebLinkAbout1890 RUTHERFORD RD; ; AS040008; Permit10/27/21, 10:20 AM AS040008 Permit Data City of Carlsbad Sprinkler Permit 1890 RUTHERFORD Job Address: RD Permit Type: SPRINK Parcel No: 2121203500 Lot #: 0 Reference No.: PC #: Permit No: AS040008 Status: ISSUED Applied 1/29/2004 Approved: 2/4/2004 Issued: 2/4/2004 Inspector: Project Title: ISIS SCIF ROOM OH AS PLAN CHECK & INSPECTIONS Applicant: WEST COAST FIRE PROTECTION 512 W. CALIFORNIA AVE. SUITE #105 VISTA, CA (760)754-8472 Owner: PDG CARLSBAD 47&48 L P 4330 LA JOLLA VILLAGE DR #110 SAN DIEGO CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 100 0 100 0 1/1 .4- o S tqcul Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 AddaL (ENTRAL Customer Service/Sales: Tel: (215) 362-0700 /(800) 523-6512 Fax: (215) 362-5385 Series TYFRB - 289r 42,56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the Page 1 of 8 chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their tire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Model/Sprinkler Identification Numbers TY1131 - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.8K, 1/2"NPT 1V2131 - Upright 4.2K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.6K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.0K, 3/4"NPT TY4231 - Pendent 8.0K, 3/4NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval information including corrosion resis- tant status.) APRIL, 2003 Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 2.8 GPM/psi1/2 (40,3 LPM/bar1/2) K = 4.2 GPM/psi112 (60,5 LPM/bar1/2) K = 5.6 GPM/p5i112 (80,6 LPM/bar112) K = 8.0 GPM/psi"2 (115,2 LPM/bar1I) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............Bronze Button ........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ..............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze TFPI 71 Page 2 of 8 TFPI7I ESCUTCHEON PLATE SEATING SURFACE \c - 2-1/4" ______ (57,2 mm) 1-9116" 39,7 mm) SSP DEFLECTOR* 2-7/8" (73,0 mm) DIA SSU' DEFLECTOR 7/16" (11,1 mm) I 1 NOMINAL I MAKE-IN I 2-3/16" WRENCH t (55,6 mm) FLATS 1 1/2' NPT** f 7/16"(111,11 mm) STYLE 100r20 0 ** NOMINAL RECESSED NPT MAKE-IN ESCUTCHEON PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4-Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression 7- Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY113I) AND PENDENT (7Y1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE T__ 2-3/16" 6mm) (55,6mm) 1 (38, 7/160(11,1 mm) ,** NOMINAL NPT MAKE-IN STYLE 100r20 RECESSED SSU* ESCUTCHEON DEFLECTOR / 7/16° (11,1 mm) I I I c_IL II \ NOMINAL .1 MAKE-IN WRENCH (55,6 mm MA ) 2-3/16" FLATS 1I2"NPT t 6* lii SSP DEFLECTOR* h— 27/80 (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT(TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I Page 3of8 ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED * SURFACE NPT MAKE-IN ESCUTCHEON SSU DEFLECTOR (55,6 mm) NOMINAL 4 No it (38,1 mm) v V R E NN (C Ht (55,6 mm) J SSP DEFLECTOR * 2-7/8"(73,0 mm) DIA. 1/2" NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING ** NOMINAL SURFACE MAKE-IN NPT 2J16., \ $ (58,7 mm) I I (9,m) \i i J SSP DEFLECTOR 2 PENDENT REC STYLE 30 or 40 RECESSED SSU' ESCUTCHEON DEFLECTOR _I 6* TrI \ (12,7 mm) I -u-7 j1 NOMINAL I : 1/2' 1 MAKE-IN 2-1/4" 57,2 mm) / 3 3/4NPT** t UPRIGHT CROSS SECTION WRENCH FLATS -7/8"(73,0 mm) DIA. ESSED PENDENT 1 - Frame 3- Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Usting is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Page 4 of 8 TFPI7I SPRINKLER FINISH (See Note 7) K I TYPE TEMP. BULB LIQUID NATURAL I BRASS CHROME PLATED I WHITE IPOLYER 2.8 PENDENT (TY1231) and UPRIGHT (TY1131) 135°F/57°C Orange 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°17193°C Green 286°F/141°C Blue 1/2° NPT 135°17/571C Orange 1,2,5 RECESSED PENDENT (TY2231)* Figure 5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 135°F/57*C Orange RECESSED PENDENT (TY2231) Figure 6 155°F/68°C Red 175°F179°C Yellow 200°F/93°C Green 4.2 1/2° NPT PENDENT (TY2231) and UPRIGHT (rY3131) 135°F157°C Orange 1,2 155°F168°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F1141°C Blue 135°F/57°C Orange RECESSED PENDENT (TY2231)° Figure 7 155°F/68°G Red 175°F179°C Yellow 200°F/93°C Green 135°F/570C Orange RECESSED PENDENT (rY2231)° Figures 155°F/68°C Red 175°F179°C Yellow 200°F193°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10(1/2° NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Re- cessed Escutcheon, as applicable. Installed with Style 20(1/2° NPT) or Style 30 (3/4° NPT) 1/2° Total Adjustment Re- cessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to all colors (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Installation The Series TY-FRB Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F1141°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. tbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft. lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nrn) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRO Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the