Loading...
HomeMy WebLinkAbout1896 RUTHERFORD RD; ; AS020017; PermitSprinkler Permit Permit No: AS020017 1896 RUTHERFORD Job Address: Status: ISSUED RD Permit Type: SPRINK Applied 1/30/2002 Parcel No: 2121203000 Approved: 2/5/2002 Lot #: 0 Reference No.: Issued: 2/5/2002 PC #: Inspector: Project Title: ISIS PHARMACEUTICALS Sprinkler plan check Applicant: Owner: P D G CARLSBAD 46 LTD 4330 LA JOLLA VILLAGE DR #110 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 100 0 100 I 0 5, V Asmoov+ 1' - - Fire Protection by Computer Design GRINNELL FIRE PROTECTION 9630 RIDGEFIAVEN CT. SUITE B SAN DIEGO CA. 92123 858 279-1980 Job Name : ISIS NEZ Building. ISIS PHARMACEUTICALS Location : 1896 RUTHERFORD ROAD CARLSBAD, CA 92008 System Contract : 087-403061 Data File : ISISNEZ.WXF V GRINNELL FIRE PROTECTION Page 2 ISIS MEZ Date Hydraulic Design Information Sheet Name ISIS MEZZANINE Date 1/29/02 Location - 1896 RUTHERFORD ROAD CARLSBAD, CA 92008 Building - ISIS PHARMACEUTICALS System No. - Contractor - Contract No. - 087-403061 Calculated By - A.S. Drawing No. - 1 OF 1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 261 -0" Occupancy - OH II S (X) NFPA 13 ( ) Lt. Haz. Ord.Flaz.Gp. ( ) 1 (X) 2 ( ) 3 C ) Ex.Haz. Y NFPA 231 C ) NFPA 231C Figure Curve S Other T Specific Ruling Made By Date B M Area of Sprinkler Operation - AREA System Type Sprinkler/Nozzle Density - .2 (X) Wet Make GEM D Area Per Sprinkler - 130 MAX. Dry Model A E Elevation at Highest Outlet - 26' Deluge Size 1/2 S Hose Allowance - Inside - Preaction K-Factor 5.6 I Rack Sprinkler Allowance - Other Temp . Rat .2 00 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - 440.39 Press Required - 58.52 At Test Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: I Tank or Reservoir: A Date of Test - 9-1-2000 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 120 @ Press - R Residual Press - 110 Elev. - Well Flow - 1450 Proof Flow S Elevation - U P Location - 1891 RUTHERFORD RD. AND FARADAY AVE. P L Source of Information - CARLSBAD FIRE DEPARTMENT Y C Commodity. Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled Palletized % M Rack Encap. Non SR TA 0 R K A G E Single Row Double Row Mult. Row Flue Spacing Longitudinal )Conven. Pallet ( ) Auto. Storage Slave Pallet ( ) Solid Shelf Open Shelf Clearance:Storage to Ceiling Transverse Horizontal Barriers Provided: GRINNELL FIRE PROTECTION Page 3 ISIS MEZ Date City Water Supply: Pump Data: Cl-Static Pressure: 120 PSI C2-Residual Pressure: 110 PSI C2-Residual Flow: 1450 GPM 150 140 130 P 120 R 110 E 100 90 S 80 U 70 R 60 E 50 40 30 20 10 200 400 600 800 1000 1200 1400 1600 .1800 FLOW (NA 1.85) omnhl r R r F-' r on rams n V -I \,(h T?-I I f- I I F I F - VU I I II II I .I III I'd - fl - I I.Ffl II UI F (1 - . Di-Elevation: 2.599 PSI D2-System Flow:190.39 GPM D2-System Pressure: 58.521 PSI Hose ( Adj City ) :0 GPM Hose ( Demand ) :250 GPM 03-System Demand:440.39 GPM Safety Margin: 60.376 PSI - . - - Cl -. . C2 o ---------- - ___________________ D2 . . . —o 3 . . . . p - GRINNELL. FIRE PROTECTION Page 4 ISIS MEZ Date Node No. Elevation . K-Fact Pt Actual Pn Actual Flow Added Density Req. Area Press Req. 1 9 5.6 18.37 na 24 .2- 120 18.37 2 9 5.6 20.19 na 25.16 .2 120 18.37 3 9 5.6 27.58 na 29.41 .2 120 18.37 4 9 5.6 18.85 na 24.32 .20 120 18.37 5 . 9 5.6 20.72 na 25.49 .20 120 18.37 6 9 5.6 28.29 na 29.79 .20 120 1.8.37 7 7 5.6 33.1 na 32.22 .20 120 18.37 Ml 9 29.35 na M2 9 30.1 na M3 .9 . 32.73 na M4 9 38.07 na Ri 26 45.86 na R2 26 46.15 na - TOR 26 46.18 na BOR 1 57.01 na VG1 -3 58.77 na VG2 - -3 58.9 na BKl 3 56.32 na BK2 3 - 58.34 na VG3 -3 60.96 na HOSE. -3 61.12 na 250 TEST 3 58.52 na The maximum velocity is 24.93 and it occurs in the pipe between nodes M3 and M4 GRINNELL FIRE PROTECTION Page 5 ISIS MEZ Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 24.00 1.049 10.000 18.370 K Factor = 5.6 to 120 2 24.00 0.1823 10.000 1.823 Vel = 8.909 2 25.17 1.049 iT 5.000 8.330 20.194 K Factor = 5.6 to 120 5.000 Ml 49.17 0.6872 13.330 9.161 Vel = 18.253 49.17 29.355 K Factor = 9.08 3 29.41 1.049 iT 5.000 1.670 27.582 K Factor = 5.6 to 120 5.000 Mi 29.41 0.2655 6.670 1.771 Vel = 10.918 29.41 29.353 K Factor = 5.43 4 24.32 1.049 10.000 18.854 K Factor = 5.6 to 120 5 24.32. 0.1869 10.000 1.869 Vel =' 9.028 5 25.49 1.049 iT 5.000 8.330 20.722 K Factor = 5.6 to 120 5.000 M2 49.81 0.7039 13.330 9.383 Vel = 18.491 49.81 30.105 K Factor = 9.08 6 29.79 1.049 iT 5.000 1.670 28.291 K Factor = 5.6 to 120 5.000 M2 29.79 0.2720 6.670 1.814 Vel = 11.059 29.79 30.105 K Factor = 5.43 7 32.22 1.049 iT 5.000 9.580 33.099 K Factor = 5.6 to 120 2E 2.000 9.000 -0.866 M4 32.22 0.3144 18.580 5.842 Vel = 11.961 32.22 38.075 K Factor = 5.22 Ml 78.58 1.61 iT 8.000 8.630 29.354 to 120 8.000 M3 78.58 0.2031 16.630 3.378 Vel = 12.384 78.58 32.732 K Factor = 13.73 M2 79.59 1.61 iT 8.000 4.630 30.104 to 120 8.000 M3 79.59 0.2080 12.630 2.627 Vel = 12.543 M3 78.58 1.61 7.210 32.731 to 120 M4 158.17 0.7409 7.210 5.342 Vel = 24.927 M4 32.22 2.067 3L 3.000 30.000 38.073 to 120 iT 10.000 19.000 -7.363 Ri 190.39 0.3092 49.000 15.152 Vel = 18.203 GRINNELL FIRE PROTECTION Page 6 ISIS MEZ Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv kk Notes ****** Point Qt Pf/UL Eqv. Ln. Total Pf Pn Ri 6.357 1L 11.316 175.000 45.863 to 120 iT 37.720 49.036 R2 190.39 0.0013 224.036 0.291 Vel = 1.925 R2 8.249 2L 14.457 29.000 46.154 to 120 28.914 TOR 190.39 0.0004 57.914 0.021 Vel = 1.143 TOR 8.249 25.000 46.175 to 120 10.828 BOR 190.39 0.0004 25.000 0.009 Vel = 1.143 BOR 6.16 1L 12.911 9.000 57.012 to 140 12.911 1.732 VG1 190.39 0.0011 21.911 0.025 Vel = 2.050 VG1 6.08 120.000 58.769 to 150 VG2 190.39 0.0011 120.000 0.128 Vel = 2.104 VG2 6.16 1L 12.911 6.000 58.898 to 140 12.911 -2.599 BK1 190.39 0.0012 18.911 0.022 Vel = 2.050 BK1 6.065 1L 9.000 0.500 56.321 to 120 9.000 2.000 Fixed loss = 2 31<2 190.39 0.0017 9.500 0.016 Vel = 2.114 31<2 6.16 1L 12.911 6.000 58.336 to 140 12.911 2.599 VG3 190.39 0.0012 18.911 0.022 Vel = 2.050 VG3 6.08 1G 4.588 100.000 60.956 to 150 1T 45.881 50.467 HOSE 190.39 0.0011 150.467 0.161 Vel = 2.104 HOSE 250.00 6.08 0.500 61.117 Qa = 250 to 150 -2.599 TEST 440.39 0.0060 0.500 0.003 Vel = 4.867 440.39 58.521 K Factor = 57.57 Cmri,I- 1, 111 1.74 1-S--,,,, M U 11Q7\ f) 07 Asoico L' FIRE SPRINKLER EQUIPMENT SUBMITTAL ISIS PHARMACEUTICALS 1896 RUTHERFORD ROAD CARLSBAD, CA. 92008 MEZZANINE GFP job # 087-403061 A9 SIMPLEXGRJINNELL 9855 CARROLL CANYON ROAD SAN DIEGO, CALIFORNIA 92131 (858) 740-0100 C-16/C-10 280525 m) MODEL F700 RECESSED ESCUTCHEON SSU DEFLECTOR 7/16" [11,1 mm) JOMINAL MAKE-IN 2-3/16" (55,6 mm) WRENC FLATS 2-7/8" (73,0 mm) DIA. 1/2" NPT ** 6* TYCO FIRE PRO - _____ Gem . ee,n DUCTS, 7071 S. 13th Street, Suite 103 oak Creek, WI 53154— www.gemsprinkIer.com Customer Service/Sales: Tel: (877) 436-826 / Fax: (877) 866-9250 Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 PENDENT, RECESSED PENDENT, AND UPRIGHT SPRINKLERS UNIVERSAL MODEL A STANDARD RESPONSE, 5 mm BULB TYPE, 5.6 K-FACTOR, 1/2" NP* ESCUTCHEON 7/16" (11,1 m PLATE SEATING NOMINAL SURFACE MAKE-IN 2-3/16" NPT (55,6 mm) f (38,1 mm) SSPDEFLECTOR* L PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3 - Gasketed 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Spring 5 - Compression orifice seat on frame. Plate Screw ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE A 5.6 K-FACTOR STANDARD RESPONSE MODEL A PENDENT (SIN G7571) AND UPRIGHT (SIN G7570) SPRINKLERS The 5.6 K-Factor Standard Response Universal Model A Pendent, Recessed Pendent, and Upright Sprinklers (Ref. Figure A) are automatic sprinklers of the "standard response" frangible bulb type. They are "standard spray sprin- klers" intended for use in fire sprinkler systems designed in accordance with the standard installation rules recog- nized by the applicable Listing or Ap- proval agency. (e.g., UL Listing is based on NFPA 13 requirements). The Pendent, Recessed Pendent, and Up- right Sprinklers all produce a hemi- spherical water distribution pattern be- low the deflector. The recessed versions of the Model A Sprinkler are obtained by utilizing the Model A Pendent Sprinkler in combi- nation with the Model F700 Recessed Escutcheon (Ref. Figures A and B). The F700 Recessed Escutcheon pro- vides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of adjustment from the flush pendent position. Wax and lead coatings are utilized to extend the life of copper alloy sprin- klers beyond that which would other- wise be obtained when exposed to cor- Printed in U.S.A. 3-01 rosive atmospheres. Although wax and lead coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all pos- sible corrosive atmospheres. Conse- quently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resis- tant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemi- cals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTE The intermediate level version of the Model A Pendent Sprinkler is ob- tained by utilizing the Model A Pen- dent Sprinkler (SIN G571) in combi- nation with the Model Q-67 Shield described in Technical Data Sheet TDSO1M. Laboratory listings and approvals for the 5.6 K-Factor Model A Pendent, Recessed Pendent, and Upright Sprin- klers are given in Table A. WARNING The 5.6 K-Factor Model A Pendent, Recessed Pendent, and Upright Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as applicable standards of the National Fire Protection Association, in addi- tion to the standards of any other authorities having jurisdiction. Fail- ure to do so may impair the integrity of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con dition. The installing contractor or manufacturer should be contacted relative to any questions. Installation of Model A Pendent Sprinklers in recessed escutcheons other than the F700 will void all sprinkler warranties, as well as pos- sibly void the sprinkler's Approvals and/or Listings. The 5.6 K-Factor Model A Pendent,. Recessed Pendent, and Upright Sprin- klers are rated for use at a maximum service pressure of 175 psi (12,1 bar) and they are available in the tempera- TD516M SPRINKLER FINISH TYPE TEMPERATURE RATING BULB LIQUID COLOR NATURAL BRASS I CHROME JPOIYESTER I PLATED I I COATED (All Colors) LEAD COATED CORROPROOF WAX COATED CORROPROOF WAX OVER LEAD COATED PENDENT (G7571) and UPRIGHT (G7570) 135017/570C Orange 1, 2,3,5, 6,7 1,2,3 1,2,3 1,2,3 155017/680C Red 1750F/79°C Yellow 200°F/930C Green 286°F/1 41°C Blue 1**,2**, 3** 2, 3** 360017/1820C Mauve N/A RECESSED PENDENT (G7571)* 1350F/57°C Orange 1, 2, 4, 6, 7 1, 2, 6, 7 N/A 1550F/680C Red 175°F/790C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. Listed by Underwriters' Laboratories of Canada. Approved by Factory Mutual Research Corporation. Approved by Factory Mutual Research Corporation. (FM limits recessed sprinklers to light and ordinary hazards, and recessed sprinklers used for ordinary hazards are limited to wet pipe systems or preaction systems qualifying as wet pipe systems.) Approved by the Loss Prevention Council (United Kingdom). Approved by the Scientific Services Laboratory (Australia). Accepted by the City of New York under MEA 241-94-E. * Installed with. 1/2" Model F700 Recessed Escutcheon. ** 150°F/66°C Maximum Ceiling Temperature. N/A: Not Available TABLE LABORATORY LISTINGS AND APPROVALS ture ratings and finishes indicated in Table A. The nominal flow 'Q" in GPM (LPM) is determined by the following formula: where the nominal discharge coeffi- cient "K" equals 5.6 (80,7) and "p" equals the residual flowing pressure in psi (bar). The Frame of the Model A Sprinkler (Ref. Figure A), is a dezincification re- sistant bronze, and the Deflector is brass. The Button and Compression Screw are bronze. The Gasketed Spring Plate consists of a beryllium nickel disc spring that is sealed on both its inside and outside faces with a Teflonf gasket. The standard re- sponse Model A Sprinklers utilize a.5 mm diameter frangible bulb. Table A indicates the bulb liquid color as a function of temperature rating. NOTES Inquiries concerning the appropriate- ness of wax or lead coated sprinklers for a given corrosive environment should be submitted to the attention of the Technical Services Department. Wax or lead coated sprinklers are not suitable for use in open sprinkler ap- plications. INSTALLATION NOTES Do not install any bulb sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontal, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 360°F/182°C temperature rating. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprin- klers with 1/2 NPT connections. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. When an escutcheon plate is utilized, do not attempt to make-up for insuffi- cient escutcheon plate adjustment by under- or over-tightening the sprin- kler. Readjust the position of the sprinkler fitting to suit. The Model A Pendent and Upright Sprinklers must be installed in ac- cordance with the following instruc- tions.. Step 1. Pendent sprinklers are to be installed on the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler. Wrench (Ref. Figure C), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figure A, the W-Type 6 Sprinkler Wrench or the Crescent wrench, as applicable, is to, be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrenching flanges. After wrench tightening the sprinkler, loosen the wrench jaws before remov- ing the wrench.. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. j f DuPont Registered Trademark FULLY RECESSED DIMENSIONSt Up to 1/2 inch adjustment from minimum 1/4 inch to maximum 3/4 inch recessed position. Dien. Inches MM A- 5/8±1/8tt 15,9±3,2 B-Mm. 3/4 19,1 B-Nom. 1 25,4 B-Max. 1-1/4 31,8 C-Mm. 1/4 6,4 C-Max. 3/4 19,1 HIGH ADJUSTMENT DIMENSIONS Up to 3/4 inch adjustment from the flush ceiling position to 3/4 inch recessed position. DIm. Inches MM A- 1/2±1/4ff 12,7±6,4 B-Mm. 3/4 19,1 B-Nom. 1-1/8 28,6 B-Max. 1-1/2 38,1 C-Mm. FLUSH - C-Max. 3/4 19,1 /ENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) FIGURE C W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS 2-7/8" DIA. (73,0 mm) 2-1/401A. (57 2 mm) FACE OF FITTING MOUNTING SURFACE B 2a1 1/8" 1 .0 y (3,2 mm) t For best overall appearance. PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE D W-TYPE7 RECESSED SPRINKLER WRENCH Closure over the Mounting Plate until its flange comes in contact with the ceiling. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuccess- ful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod angled downward, and then touch the wax stick to the rod approximately one-half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. The Model A Recessed Pendent Sprinklers must be installed in ac- cordance with the following instruc- tions. Step A. Verify that the face of the sprinkler fitting is within, the proper range of distance which can be accom- modated by the Model F700 Recessed Escutcheon. For best overall appearance, use Di- mension 'A" indicated under the "Fully Recessed Dimensions" heading of Figure B. Otherwise, use Dimension "A" under the "High Adjustment Di- mensions" heading. In either case, the remaining adjustment can be used to compensate for the possible manufac- turing variations in take-out of the fit- ting, as well as in the make-in of the sprinklers (as permitted by ANSI B1.20.1). Step B. After installing the F700 Mounting Plate over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure D). With reference to Figure A, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the F700 Closure over the Model A Sprinkler and push the The Model A Sprinklers must be main- tained and serviced in accordance with the following instructions: NOTES Before closing afire protection system control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and allpersonnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be shipped or stored where their tempera- tures will exceed 100°F/380C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of com- bustion, but have not operated, should be replaced if they cannot be com- pletely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench 1- Model A Pendent Sprinkler I-f Remaining 1/4 inch (6,4 mm) of 2- Model F700 Recessed Escutcheon adjustment can be used to compensate a- Mounting Plate for variations in sprinkler make-in and b- Closure fitting take-out. FIGURE B MODEL A RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE MODEL F700 RECESSED ESCUTCHEON twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). Frequent visual inspections are rec- ommended to be initially performed for wax and/or lead coated sprinklers, af- ter the installation has been com- pleted, to verify the long term potential integrity of the sprinkler coatings. Thereafter, annual inspections per NFPA 25 should suffice; however, in- stead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the wax and/or lead coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. LIMITED WARRANTY Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDI- RECT, SPECIAL OR CONSEQUEN- TIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR- POSE. A Product Symbol Number (PSN) is not specified when ordering sprinklers with thread connections per ISO 7/1. When ordering Corroproof wax coated sprinklers, consideration should be given to ordering Corroproof Wax Sticks for field repairing any wax coat- ing on the sprinkler wrenching area that may become damaged during sprinkler installation. Contact your local distributor for avail- ability. Sprinkler Assemblies: Specify: 5.6 K-Factor, (specify tem- perature rating), Standard Response Model A (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), PSN (specify from Table B). "Special Order" Sprinkler Assemblies with ISO 7/1 Thread Connections: Specify: 5.6 K-Factor, (specify tem- perature rating), Standard Response Model A (specify Pendent or Upright) Sprinkler with (specify type of finish or coating) and with thread connection per ISO 7/1. Recessed Escutcheon: Specify: 1/2" (15 mm) Model F700 Re- cessed Escutcheon with (specify fin- ish), PSN (specify). 1/2° (15 mm) F700 Chrome Plated.........PSN 56-701-9-010 1/2° (l5 mm) F700 White Color Coated ...............PSN 56-701-4-010 Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, PSN 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, PSN 56-850-4-001. Corroproof Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Model A Sprinklers, PSN (specify). Black for 135°F ...........PSN 56-065-1-135 Red for 155°F ............PSN 56-065-1-155 Yellow for 175°F .........PSN 56-065-1-175 Blue for 200°F and 286° F ................PSN 56-065-1-286 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 200°F sprinklers, and, therefore, the 286°F sprinkler is lim- ited to the same maximum ceiling temperature as the 200°F sprinkler (i.e., 150°F). PSN-57 - XXX - X - XXX TEMPERATURE RATING SPRINKLER I________________ FINISH I 135 1 135°F157°C 1 I NATURAL BRASS I I 155 I 1550171680C 4 I WHITE POLYESTER I I 175 I 1750F/790C TYPE I I 9 I CHROME PLATED I I 200 I 200°17/93°C 571 I SR PENDENT I I 7 I LEAD COATED I I 286 I 2860F/1410C 570 1 SR UPRIGHT 6 WAX COATED 360 360017/1 82°C 286017/1410C I 8 1 WAX OVER LEAD 286°F/1 41°C MAXIMUM TABLE B PRODUCT SYMBOL NUMBER SELECTION 5.6 K-FACTOR MODEL A PENDENT AND UPRIGHT SPRINKLERS WITH 1/2 INCH NPT CONNECTIONS J tqCa/F/ow Control/ Tyco Fire Products