Loading...
HomeMy WebLinkAbout2200 FARADAY AVE; ; FS090008; Permit10/28/21, 9:23 AM FS090008 Permit Data City of Carlsbad Fixed Systems Permit Job Address: 2200 FARADAY AV Permit Type: FIXSYS Parcel No: 2121204100 Lot #: 0 Reference No.: Permit No: FS090008 Status: ISSUED Applied 2/11/2009 Approved: 2/11/2009 Issued: 2/11/2009 PC #: Inspector: Project Title: SIERRA WIRELESS SPECIAL CHEMICAL SUPPRESSION PLAN CHECK & INSPECTION Applicant: SCHMIDT FIRE PROTECTION CO INC 4760 MURPHY CANYON RD SAN DIEGO, CA 92123 858-279-6122 Owner: D L FARADAY L P C/O DRA ADVISORS LLC 220 E 42ND ST #27 NEW YORK NY rFees ($) Add'I Fees ($) Total ($) Balance ($) 130 10 130 0 1/1 H 0 66 PASSIFAIL Enclosure Integrity Report 0C\ 0008 CleanAgent 2001 retention time prediction program revision 2.5.4. Complies with ISO draft standard 15420-1 g I So5 By Retrotec, Inc, 2200 Queen Street, Bellingham, WA USA 98229 360-738-9835 www.retrotec.com Software Licensed to: Schmidt Fire Protection Co. Inc. air leaks in Building, Location seaira wireless, SAN DIEGO, CA Company, Contact - Room name chamber 114 Test number 6 Calibration Certificate # 3745 Certificate created 2008112105 'FILE COP'' agent leaks out Test date/time 2009/03/25 10:42 Net protected volume, V 517 ftA3 Tester Sample Tech Maximum Protected Height, H0 8.00 ft ertified to Level: 4 - ISO multi-point & vent test Minimum Protected Height, H 6.00 ft Signature Static during discharge, P$ft 0.0 Pa above sea level 751 ft Operating temperature 70 F rrection method [Actual NFPA 2001 (2000) Formula A-3-5.3.3 Initial concentration, C 7.32% orrection factor 0.97 Mixing during retention No Agent FM200 (HFC227ea) Agent quantity 18 lb. otal leakage, A 0.08 ftA2 Minimum concentration, Cmin 7.32% wer leakage, A 0.04 ftA2 Minimum retention time 10.0 minutes Below ceiling leakage defaulting to worst case -- 50% of total leakage. This enclosure was tested in compliance with ISO 14520.1 Annex E. Assuming no continual mixing during the retention period, enclosure leakage could allow sufficient agent to be lost to cause an air/agent interface to descend from a Maximum Protected Height of 8.00 ft. to the Minimum Protected Height specified of 6.00 ft. The retention time would then be 10.8 minutes which exceeds the minimum retention time of 10 minutes. The enclosure therefore oasses this acceDtance orocedure. Notes Witnesses Printed on: 2009/03/25 10-51 Page 1 DOOR FAN TEST -- Graph CleanAgent 2001 retention time prediction program revision 2.5.4. Complies with ISO draft standard 15420-1 By Retrotec, Inc, 2200 Queen Street, Bellingham, WA USA 98229 360-738-9835 www.retrotec.com Software Licensed to: Schmidt Fire Protection Co. Inc. air leaks in Building, Location seaira wireless, SAN DIEGO, CA Company, Contact DPR, Perry Room name chamber 114 Test number 6 Calibration Certificate # 3745 Certificate created 2008112105 agent leaks out Printed on- 2009/03/25 10:51 Page DOOR FAN TEST-- Total Room Leakage Data CleanAgent 2001 retention time prediction program revision 2.5.4. Complies with ISO draft standard 15420-1 By Retrotec, Inc, 2200 Queen Street, Bellingham, WA USA 98229 360-738-9835 www.retrotec.com Software Licensed to: Schmidt Fire Protection Co. Inc. air leaks in Building, Location seaira wireless, SAN DIEGO, CA Company, Contact DPR, Perry Room name chamber 114 Test number 6 Calibration Certificate # 3745 Certificate created 2008112105 agent leaks out Total Room Leakage Operator Out of the room Smoke doesn't move Temperature during test (F) Static pressure 0 Pa 70 inside 70 outside essurization Range ower range Room pressure -13.6 Auto corrected RP -13.5 Cl Flow Pressure 30 I Auto corrected FP 29.7 Corrected flow (ftA3/mjn room oressures: -10.6 to -13.6 Pressurization Range for room pressures: 10.6 to 13.6 Blower range Room pressure! 13.1 Auto corrected RPI 13 Cl I I Auto corrected FPI 16.2 Corrected flow (ftA3/min.)1 441 Pressurization Depressurization Average Slope n Intercept k Correlation Standard Error ELAft"2 I I 0.5000 11.94 NA NA 0.5000 12.24 NA NA 0.5000 12.09 0.08 I 10.0 I 0.50 I Lower Leakage Below ceiling leakage of 0.04 ft"2 @ 10.0 Pa is the worst case assumption of 50% Technician: Sample Tech Certified to Level: 4-ISO multi-point & vent test Yes Level 1 - Fire enclosure design basics for improving agent retention and passive protection Yes Level 2 - adds single door fan operation and NFPA clean agent retention time calculations Yes Level 3-adds double door fan operation for Lower Leak measurement Yes Level 4 - adds multi-point ISO door fan operation and discharge pressure relief vent Printed on: 2009/03/25 10:51 Page 2 -I. '?HJ €&W March 7, 2008 Sprinkler ha The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com 1. DESCRIPTION Viking Micromatic and MicromaticHP6 Standard Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different fin- ishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester and Teflon coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon and Polyester coat- ings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page lib. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, 2006, 2015, and 2017 NYC Approved: MEA 89-92-E, Volume 12 ABS Certified: Certificate 04-H5407984A-PDA VdS Approved: Certificate G4040096, G4040098. G4060058, G4060059, G4980001 G4980002, G4980005, and G4980007 LPC Approved: Ref. No. 096e106 and 167a/04 CE Certified: Standard EN 12259-1. EC-certificate of conformity 0786-CPD-40141, 0786-CPD-40181, 0832-CPD-2001, and 0832-CPD-2003 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008, and RINA Certificate No. MED497705C5 NOTE: Other International approval certificates are available upon request. Refer to the Approval Charts on pages lid-f and Design Criteria on page hf for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1997. Minimum Operating Pressure: Refer to the Approval Chart Maximum Working Pressure: Sprinklers VK023 and VK122 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831.870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts Viking Technical Data may be found on The Viking Corporation's Web site at http:llwww.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 10139, 10142, 10170, 10173, 10223, and 12105. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 09994, 10189, 10221, and 10222): Brass UNS-C36000 Bulb: Glass, nominal 5 mm diameter Form No. F_100397 Replaces page ha-h, dated October 12, 2007. (Added Dry System note in approval chart for Small Orifice) Sprinkler lib March 7, 2008 Microma '.3f CO AND ii The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap for Sprinklers 09992, 09994, and 10221: Brass UNS-C31400 or UNS-C31600 Pip Cap and Insert Assembly for all other Sprinklers: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12105): Stainless Steel For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® and MicromaticHP® Standard Response Pendent Sprinklers by first adding the appropriate suffix for the sprin- kler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-AN. Black Polyester = M-/B, Black Teflon® = N, Wax Coated = C, Wax Over Polyester ' V-/W Temperature Suffix (F/°C): 135/57 A, 155°/68° = B, 175°/79 = D, 200°/93° = E, 212°/100° = M, 286I141 G, 360°/182° = H 500°/260° = L, OPEN = Z (Teflon only). For example, sprinkler VK102 with a 1/2" thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 101 39A Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for recessed sprinklers: Part No. 12144W/B* (available since 2003) Wrench for wax coated sprinklers: Part No. 13577W/B** (available since 2006) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W1B. *A %" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 197 1) INSTALLATION Refer to appropriate NFPA Installation Standards, OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection. Testing and Maintenance requirements. AVAILABILITY The Viking Micromatic® and MicromaticHP® Standard Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flo.t Protective Sprinkler Cap 110896 Q Figure 1: Standard Sprinkler Wrench 10896W/B March 7, 2008 Sprinkler 11 Micromaticl-IPO STANDARD RESPONSE PENDENT LN SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com SrinklerTempérature Sprinkler Nominal Maximum Ambient U 0 or B lb Col Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 °C) 100 °F (38 00) Orange Ordinary 155 °F (68 'C) 100 °F (38 00) Red Intermediate 175 °F (79 0C) 150 °F (65 00) Yellow Intermediate 200 °F (93 00) 150 °F (65 00) Green Intermediate 212 °F (100 00) 150 °F (65 °C) Green High 286 °F (141 00) 225 °F (107 °C) Blue Extra High 360°F(182°C) 300°F(149°C) Mauve Ultra High' 500 °F (260 00) 465 °F (240 00) Black Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® in all temperature ratings. Wax-Coated Brass and Wax over Pclyester5 for sprinklers with the following temperature ratings: 135 °F (57 00) Off-White Wax 155 °F (68 00) Lt. Brown Wax 175 °F (79 00) Brown Wax 200 °F (93 00) Brown Wax 212 °F (100 00) Dk. Brown Wax6 286 °F (141 °C) Dk. Brown Wax6 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Othe- limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal oper- ating temperatures above 300 °F (149 00) Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 00) response time may be severely retarded. ' The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 11 d-e. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. For Teflon® coated open sprinklers only, the waterway is coated. Wax Over Polyester is unavailable for Sprinklers VK023 and VK122. Wax melting point is 170 °F (76 00) for 212 °F (100 °C) and 286 °F (141 °C) temperature rated sprinklers. II_ Sprinkler Wrench )- : 12144W/B** For installing coated and/or recessed Carefully slide the pendent sprinklers wrench sideways with protective caps, ' around the protective cap, ensuring engage- ment with the sprinkler ®A 1/2w ratchet is required wrench flats. (not available From Viking). Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers Sprinkler lid March 7, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Approval Chart 1 KEY Rims Micrornatic Standard Response Pendent Sprinklers [x4 UtC Maximum 175 PSI (12 bar) WWP Sprinkler Nominal Overall Listings and Approvals' Base Part SIN Thread Size K-Factor Length (Refer also to Design Criteria on page 11 g.) Number' NPT BSP U.S. metric2 Inches mm cULus4 FM j NYC' VdS LPCB CE Standard Orifice 10139 VK102 1/2 15 mm 1 5.6 80.6 2-3/16' 56 j 81, DS, E7, F4 A3, C6, F3 Bi, D5, E7 B3 B3, D5 G312 G314'15 1017311 VK102 -- 15 mm 5.6 80.6 2-3/16" 56 81, D5, E7, F4 A3, C6, F3 Bi, D5, E7 B3 B3, D5 -- -- Large Orifice 10223 VK202 1/2" 15 mm 8.0 115.2 2-3/8" 60 Bi, D5, E7, F4 B4, D6, F4 BI, D5, E7 83 -_ -- -- 10142 VK202 3/4" 20 mm 8.0 115.2 2-5/16" 59 B1, D5, E7, F4 84, D6, F4 Bi, D5, E7 -- B3, D5 G412 G4" 10170 VK202 -- 20 mm 8.0 115.2 2-3/8" 60 B1, D5, E7 C6, A4 -- -_ B3, D5 G411 G414 12105 VK202 3/4" 20 mm 8.0 115.2 2-3/16" 56 -- -- -- 83 -- B313 -- Small Orifice' 1022110 VK003 1/2" 15mm 2.8 40.3 2-3/16" 56 1 B1, D5, E7 B4, D6 -- -- -- -- -- 10222 0 VK004 1/2" 15 mm 4.2 60.5 2-1/4" 58 81, D5, E7 -- -- -- B3, D5 -- 10175 VK004 -- 10mm 4.2 60.5 2-1/4" 58 -- -- -- B3 B3, D5 G311 0314.15 1018910.11 VK003 -- 15 mm 2.8 40.3 2-3/16" 56 81, D5, E7 84, D6 -- -- -- -- -- Approved Temperature Ratings Approved Finishes A- 135 "F (57 "C), 155 "F(68 "C), 175"F (79 "C), 200 "F (93"C), 212 "F (100 "C), 286 "F (141 "C), and 360 "F (182 "C) 1 - Brass, Chrome-Enloy', White Polyester56, Black Polyester' 6, and Black Teflon B - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), 286 "F 2- White Polyester', Black Polyester5, Black Tet1on, Wax-Coated Brass, and Wax (141 "C), and 360 "F (182 "C) C - 135 °F (57 "C), 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), and over Polyester Brass, Chrome-Enlo, White Polyester', and Black Polyester5 212 "F (100 "C) Brass and Chrome-Enloy'0 D - 135 "F (57 "C), 155 "F (68 "C), 175 "F (79'C), and 200°F (93'C) 5 - Wax-Coated Brass and Wax Over Polyester' E - 286 "F (141 "C) 6 - Wax-Coated Brass (corrosion resistant) F - 500 "F (260 "C)6 7 - High Temperature 200 "F (93 "C) Wax Coating (corrosion resistant): maximum G - 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), 286 "F (141 "C), and ambient temperature allowed at ceiling = 150 "F (65 "C) 360 "F (182 "C) 1. Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 12. "F 8 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 "F "C), (149 "C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 (149 the response time of the Ultra-High temperature rated sprinkler may be severely retarded. °Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. !'The sprinkler orifice is bushed. 11Sprinklers 10173 and 10189 are available on special order. 0832-CPD-2001 0832-CPD-2003. 12 ((Certified, Standard EN 12259-1, EC-certificate of conformity and (E Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40141 and 0786-CPD-401 81. 14 ® MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. . MED Certified, RINA Certificate No. MED497705C5. March 7, 2008 Sprinkler lie VA Al -A MICROMATICID AND TEC JLATI4 -Micromaticl-!Pl~l STANDARD The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Approval Chart 2 Micromatic Standard Response Pendent Sprinklers Fn1 AIX 4 Eh f L Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals' Base Part SIN K-Factor Length (Refer also to Design Criteria on page 11g.) Number' NPT BSP U.S. J metric2 fInches mm cULus4 FM NYC' j VdS J LP(B I (E12 Installed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon 10139 VK102 1/2" 15 mm 5.6 80.6 2-3/16" 56 81 A210 81 B2 B2 C2 -- 10173" VK102 -- 15 mm 56 80.6 2-3/16" 56 81 A310 - -- B2 -- -- 10223 VK202 1/2" 15 mm 8.0 115.2 2-3/8" 60 Bi 8310 81 -- -- -- -- 10142 VK202 3/4" 20 mm 8.0 115.2 2-5/16" 59 81 B310 Bi -- B2 C2 -- 10170 VK202 -- 20 mm 8.0 115.2 2-3/8" 60 Bi 8310 - -- 82 C2 -- 12105 VK202 3/4" 20 mm 8.0 115.2 2-3/16" 56 -- -- - 82 -- 82 -- 102218,9 VK003 1/2" 15 mm 2.8 40.3 2-3/16" 56 81 A38 Bi -- -- -- -- 10222' VK004 1/2" 15 mm 4.2 60.5 2-1/4" 58 81 -- B1 -- 82 -- -- Installed with the Viking Microfast® Model F-I Adjustable Escutcheon 10139 f'K102 1/2" 15 mm 56 80.6 2-3/16" 56 81 -- 81 D2 82 -- 10223 fVK202 1/2" 15 mm 8.0 115.2 2-3/8" 60 81 - 81 82 -- -- -- 10221 8'1 L'<003 1/2" 15 mm 2.8 40.3 2-3/16" 56 81 -- Bi -- -- -- Approved Temperature Ratings Approved Finishes A - 135 °F(57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 212 °F 1 - Brass, Chrome-Enloy®, White Polyester-5 Black Polyester06, and 0 ) kTflon 0 Black e B - 135 "F (57 °C). 155°F (68 °C), 175°F (79 °C), and 200°F (93 °C) 2- Brass, Chrome-Enloy°, White Polyester6, and Black Polyestei® °C), °F C - 155°F (68 °C), 175 °F (79 and 200 (93 °C) 3 - Brass and Chrome-Enloy D - 286 °F (141 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 6cULus Listed as corrosion resistant. '0 Other colors are available on request with the same Listings and Approvals as the standard colors. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E. Vol. 12. '0 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 0 The sprinkler orifice is bushed. 11FM Approval of Viking Micromatic® Standard Response Recessed Pendent Sprinklers installed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon is limited to wet systems and preaction systems qualifying as wet systems, for hazard occupancies up to and including Ordinary Hazard, Group II. "Sprinkler 10173 is available on special order. 11(( Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40181, 0832-CPD-2001, and 0832-CPD-2003. Sprinkler 11 March 7. 2008 MICROMATIC@1 AND MicromaticHPO STANDARD Fri RESPONSE PENDENT WE 0 SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com Approval Chart 3 FwU MicromaticHP Standard Response Pendent Sprinklers Maximum 250 PSI (17 bar) WWP Sprinkler Thread Size Nominal Overall Listings and Approvals' Base Part SIN K-Factor Length (Refer also to Design Criteria on page IIg) Number' NPT BSP US. metric" Inches mm cULus4 FM NYC VdS 1 LPCB CE Standard Orifice 09992 VK122 1/2" 15 mm 5.6 1 80.6 2-1/4" 1 58 1 Al, D2 -- -- -- -- -- -- Small Orifice 099947,8 VK023 1/2" 115 mm 2.8 40.3 2-1/4" 1 58 1 Al -- -- -- -- -- -- Installed with the Viking Micromatic Model E-I or E-2 Recessed Escutcheon 09992 VK122 1/2" 15 mm 5.6 80.6 2-1/4' 58 Cl -- -- -- -- -- 09994' VK023 1/2" 15 mm 2.8 40.3 2-1/4" 58 Cl - -- -- -- -- -- Installed with the Viking Microfast Model F-I Adjustable Escutcheon 09992 VK122 1/2" 15 mm 5.6 80.6 2-1/4" 58 81 -- -- -- -- -- 0999478 VK023 1/2" 15 mm 2.8 40.3 2-1/4" 58 Bi -- -- -- -- -- -- Approved Temperature Ratings A- 135°F (57 °C), 155°F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286°F Approved Finishes 1 - Brass Chrome-Enlo'7>, White Polyesters.', Black Polyesters', and B - 135 °F7)5°F °C) 175 °F (79 "0). 200 °F (93 °C), and 286 °F Black Teflon')' (141 °C) 2- Brass and Chrome-Enlo °C) C - 135 °F (57 °C), 155 °F (68 "0), 175 "F (79 "0), and 200 °F (93 D -500°F(260°C) Footnotes I Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 8 The sprinkler orifice is bushed. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 "F (149 "C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded, March 7, 2008 Sprinkler hg MICROMATICIDAND E ECH EL & 1 TNICttDATA , YiIr.jromaticHPO STANDARD *4A RESPONSE PENDENT SPRI NKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com DESIGN CRITERIA (Also refei to the Approval Charts on pages 11 df) cULus Listing Requirements: MicromatiO and MicromaticHP® Standard Pendent Sprinklers are cULus Listed as indicated in the Approval Charts for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light, Ordinary, and Extra Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where al- lowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM AqDrovpt Requirements: Standard Pendent Sprinklers are FM Approved as indicated in the Approval Charts for installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-81N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. ,'- Sprinkler Wrench / 13577W/B* for \\ ) installing wax coated sprinklers I J Step h Carefully sUde the 7 I wrench sideways around Wax Coated I the sprinkler deflector, Pendent Sprinkler I Step 2 Carefully press **A 1/2" ratchet is required I the wrench upward and (not available fromViking), ensure engagement with the sprinkler wrench flats. Figure 3: Wrench 13577W/B for Wax Coated Sprinklers 1/2" (15 mm)__\ NPT 2-1/4" (58 mm) Pendent Sprinkler VK102 Sprinkler 11 March 7, 2008 V. I 11 iUtSTANDARD L D TECHNICAATAP RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Ceiling Opening Size: I 2—l/8 p'I 2-5/16" (58.7 mm) minimum (54 mm) 2-1/2" (63.5 mm) maximum 1-3/4" ç ' (44.5 mm) 38 mm) (51 mm) Minimum a'ximum Installed with a standard 1/8" surface— Installed with a Microfast mounted escutcheon. Model F—i Adjustable Escutcheon Figure 4: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 2-1/8" 2-1/2" (63.5 mm) maximum 21/8 (54 mm) (54 mm) 1-3/4" Minimum 1-1/8" (28.6 mm) (44.5 mm) Maximum - Installed with a Micromatic Model E-1 Recessed Escutcheon 1-1/8" (28.6 mm) (51 mm) Minimum Maximum Installed with a Model E-2 Thread—on Recessed Escutcheon Figure 5: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons Form No. F100397 Replaces page ha-h, dated October 12, 2007. (Added Dry System note in approval chart for Small Orifice) tSthmidt Fire Protection Co., Inc. 4760 MURPHY CANYON RD • SAN DIEGO, CA 92123' (858) 279-6122 • FAx (858) 279-3583 SIERRA WIRELESS 2200 FARADAY AVE. CARLSBAD, CA 92009 SUBMITTAL PACKAGE (1) FM-200 FIRE SUPPRESSION SYSTEM STARLAB ANECHOIC CHAMBER APPRV D S SUBMITTED S. CARLSEFAD YIRE DEPARTMENT em1a/Wa . o&man5 ofJe 4üz/de itho gr Kidde Fire Systems JAMES MOORE SCHMIDT FIRE PROTECTION CO. 4760 MURPHY CANYON RD. SAN DIEGO, CA Phone: PH: 858-279-6122 FAX: 858-279-3583 ECS Series - KID3.03 UL: EX4674 Project: SIERRA WIRELESS STARLAB File Name: 655-Sierra Wireless StarLab.FLC Consolidated Report Customer Information Company Name: SIERRA WIRELESS Address: 2200 FARADAY AVE. CARLSBAD, CA 92009 Phone: Contact: Title: Project Data Project Name: SIERRA WIRELESS STARLAB Designer: Number: Account: Location: Description: Page: 1 of 5 . Calculation Date/Time: Tuesday, February 10, 2009, 1:11:58 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal Sgr Kidde Fire Systems Consolidated Report Enclosure Information Elevation: 0 ft (relative to sea level) Atmospheric Correction Factor: 1 Enclosure Number: I Name: ANECHOIC CHAMBER Enclosure Temperature... Minimum: 70 F Maximum: 70 F Maximum Concentration: 7.132% Design Concentration... Adjusted: 7.131 % Minimum: 7.000% Minimum Agent Required: 17.7 lbs Width: 0.0 ft Length: 0.0 ft Height: 0.0 ft Volume: 0.0 cubic ft Non-permeable: 0.0 cubic ft Total Volume: 517.3 cubic ft Adjusted Agent Required: 18.0 lbs Number of Nozzles: I Page: 2 of 5 Calculation Date/Time: Tuesday, February 10, 2009, 1:11:58 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal Kidde Fire Systems Consolidated Report Agent Information Agent: FM-200 / Propellant N2 (FM-200 is a Trademark of Great Lakes Chemical Corp.) Adjusted Agent Required: 18.0 lbs Container Name: 20 lb Cylinder Container Part Number: 90-100020-001 Number of Main Containers: 1 Number of Reserve Containers: 0 Manifold: No Manifold Pipe Take Off Direction: Horizontal Agent Per Container: 18.0 lbs Fill Density: 54.1 lbs /cubic ft Container Empty Weight: 31.0 lbs Weight, All Containers + Agent: 49.0 lbs Floor Area Per Container: 0.27 square ft Floor Loading Per Container: 181 lbs /square ft Pipe Network Part I - Pipe Pipe Description Start End Typi Diameter Length Elevation S Main Cyl. X I Adapter Pipe Pipe/E1-N1 0 1 1 2 2 3 40T 3 4 40T 1-1/2 in 1.68 ft 1-1/2 in 0.22 ft 1/2 in 1.00 ft 1/2 in 1.00 ft 1.68 ft 0.00 ft 0.00 ft -1.00 ft Part 2 - Equivalent Length Start End 90 45 Thru Side Union Other Added Total 0 1 0 0 0 0 0 0.00 ft 50.0 ft 1 2 0 0 0 0 0 1-1/2inVOA 0.00 ft 11.8 ft 2 3 0 0 0 0 0 0.00 ft 1.0 ft 3 4 1 0 0 0 0 0.00 ft 2.7 ft Page: 3 of 5 S Calculation Date/Time: Tuesday, February 10, 2009, 1:11:58 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal 'Kidde Fire Systems Consolidated Report Part 3 - Nozzles Start End Flow Name Size - Type Nozzle Area 0 1 18.0 lbs 1 2 18.0 lbs 2 3 18.0 lbs 3 4 18.0 lbs El-Ni 1/2 in 1800 0.1342 square in Parts Information Total Agent Required: 18.0 lbs Container Name: 20 lb Cylinder (Part: 90-100020-001) Number Of Containers: I Nozzle Type Nozzle Area Part Number El-NI 1800 0.1342 square in 90-194013-144 Pipe: Type Diameter Length 40T 1/2 in 2.00 ft S 'Other Items: I - 1-1/2 in. Valve Outlet Adapter (Part: 283904) List of 90 degree elbows: 1- 1/2 in System Acceptance * WARNING - The data in this project may have been changed after the calculations were performed. System Discharge Time: 6.8 seconds Percent Agent In Pipe: 11.7% Percent Agent Before First Tee: 0.0% Enclosure Number: 1 Enclosure Name: ANECHOIC CHAMBER Minimum Design Concentration: 7.000% Adjusted Design Concentration: 7.131% Predicted Concentration: 7.132% Maximum Expected Agent Concentration: 7.132% (At 70 F) Page: 4 of 5 Calculation Date/Time: Tuesday, February 10, 2009, 1:11:58 PM O Copyright (C) Hughes Associates, Inc. Licensed to: Kidde-Fenwal Consolidated Report Minimum Adjusted Predicted Nozzle Agent Agent Agent Pressure Required Required Delivered (Average) 17.7 lbs 18.0 lbs 18.0 lbs 160 psig S fKidde Fire Systems Nozzle El-NI Standard Isometric View -k /OA El 20 lb Cii?ide- No Manifold W S Page: 5 of 5 S Calculation Date/Time: Tuesday, February 10, 2009, 1:11:58 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal I Cr,"Kidde Fire Systems Effective: February 2004 S FEATURES K-90-1900 Non-Ozone Depleting 0 Fast Acting Safe for Total Flooding of Occupied Spaces • Active Fire Suppression Agent Clean-No Residue to Clean Up • UL Component Recognized Non-Damaging to Hazard Contents • FM Approved FM-200® Fire Suppression Agent S EXTINGUISHING AGENT FM-200 (1,1,1,2,3,3,3-heptafluoropropane) is a compound of carbon, fluorine and hydrogen (CF3CHFCF3). It is colorless, odorless and electrically non-conductive. It suppresses fire by a combination of chemical and physical mechanisms without affecting the available oxygen. This allows personnel to see and breathe, permitting them to leave the fire area safely. FM-200 has acceptable toxicity for use in occupied spaces when used as specified in the United States Environmental Protection Agency (EPA) Significant New Alternative Policy (SNAP) program rules. Although FM-200 is considered non- toxic to humans in concentrations necessary to extinguish most fires, certain safety considerations should be observed when applying and handling the agent. The discharge of FM-200 may create a hazard to personnel from the undecomposed agent itself and from the decomposition products which result when the agent is exposed to fire and other hot surfaces. Ex- posure to the agent is generally of less concern than is expo- sure to the decomposition products. Unnecessary exposure to the agent or the decomposition products should be avoided. TOXICITY In tests, the acute toxicity of FM-200 was shown to be equiva- lent to that of Halon 1301. FM-200 has been evaluated for cardiac sensitization through test protocols approved by the US EPA. The EPA's SNAP Program classifies FM-200 as ac- ceptable for use as a total flooding agent in occupied spaces. Refer to the SNAP program rules for more information. CLEANLINESS FM-200 is clean, leaves no residue, thereby eliminating costly after-fire clean-up, and keeping expensive "down-time" to a minimum. Most materials such as steel, stainless steel, aluminum, brass, and other metals as well as plastics, rubber and electronic components are unaffected by expo- sure to FM-200. APPROVALS FM-200 agent complies with the NFPA Standard 2001: Standard for Clean Agent Fire Extinguishing Systems, EPA SNAP Program (Significant NewAlternate Policy), Underwrit- ers Laboratories, Inc. (UL) and Factory Mutual Research Cor- poration (FMRC). This literature is provided for informational purposes only. KIDOE-FENWAL,tNC. assumes no responsibility for the products Suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, Contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 K-90-1900 02/04 02004 Kidde-Fenwal, Inc. Printed in USA USE FM-200 is used in total flooding fire suppression systems. It is stored in steel containers, and is super-pressurized with nitro- gen to aid in expelling the agent. The discharge time is 10 seconds or less. The maximum fill density of the agent storage is 70 lb/ft.3. Table 1. FM-200 Physical Properties Chemical For mula CF3CHFCF3 Molecular Weight 170.03 Freezing Point -204°F (-131°C) Boiling Point at 1 AIm. 2.6°F (-16.4°C) Critical Temperature 215.1°F (101.7°C) Critical Density 38.76 lb./ft.3 (621 kg/M3) Critical Pressure 422 PSlA (29.0 bar absolute) Critical Volume 0.0258 cu.ft.ilb. (1.61 Llkg) Ozone Depletion Potential 0 Table 2. FM-200 Fire Protection Properties Cup Burner Concentration (n-Heptane) 6.70% v/v Use Concentration for n-Heptane 8.00% v/v Use Concentration for Acetone 8.30% v/v Use Concentration for Isopropanol 9.00% v/v Use Concentration for Toluene 7.00% v/v Use Concentration for Class A (Surface Fires)* 6.25% v/v *Note: Automatic only per NFPA 2001. Table 3. FM-200 Toxicity Properties NOAEL 9.00% (No Observable Adverse Effect Level) LOAEL 10.50% (Lowest Observable Adverse Effect Level) FM-200 is a registered trademark of the Great Lakes Chemical Corporation. Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://www.kiddefiresystems.com /4 P/N: 90-I000XI-001 SSURE GAUGE RT FROM SYPHON 3E OPEN END S FM-200® Component Description Cylinder and Valve Assemblies 10 lb. (4.5 kg) to 70 lb. (31.7 kg) Capacity, Horizontal Mount Only, Modular Balanced Systems Only Kidde Fire Systems Effective: April 2002 K-90-2020 FEATURES For use with UL Listed, ULC Listed and FM Approved Systems ORDERING INFORMATION Part Number Cyl. Size Dimensions A* B* 90-100011-001 10 Lbs. 7.07 13.34 17.30 :901 00021 -001 20 Lbs. 7.07 21.01 24.97 90-100041-001 40 Lbs. 9.00 22.80 26.76 90-100071-001 70 Lbs. 9.00 34.87 38.83 * Dimensions are in inches. MATERIALS Valve Body: Brass Cylinder: Steel, Painted Red Note: The safety cap must be installed on the valve outlet at all times, except when the cylinders are connected to the system piping, or being filled. The safetly cap must not be removed from its chain. See K-90-2070 for additional information. Cylinders are horizontal mount only. Not for use with engineered systems. FM-200 is registered trademark of the Great Lakes Chemical Corporation. This literature is provided for informational purposes only. KIDDE.FENWALtf'tC. assumes no responsibility for the products suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 K-90-2020 04/02 t2002 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://www.kiddefiresystems.com K] FM-200® Component Description Valve Outlet Adapters W~OKiddeFire Systems Effective: April 2002 K-90-2100 :1-- FEATURES For use with UL Listed, ULC Listed and • See Kidde® Manual 90-FM200M-021 for FM Approved Systems USCG Approval PIN: 28390X - B (VALVE OUTLET CONNECTION) E CONNECTION) Note: For direct connection of cylinder valve to distribution piping. S MATERIAL Brass ORDERING INFORMATION Part Size A* B* C D* Number "283904 - 1/2 1% 1.874 2.69 2.50 HEX 11Y2NPT 12UNJ 283905 2 2 2.500 3.12 3.00 HEX 11%NPT 12UNJ 21/2 3.00 3.00 283906 21 8NPT 3.0 3.00 3.75 HEX *Note: Dimensions are in inches. FM-200 is a registered trademark of the Great Lakes Chemical Corporation. This literature is provided for informational purposes only. KlDDE-FENWAL,lNC. assumes no responsibility for the product's suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 K-90-2100 04/02 ©2002 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://www.kiddeliresystems.com FM-200® Component Description (gKiddeFire Systems Electric Control Head, Stackable Explosion Proof Effective: April 2002 K-90-8017 . . FEATURES For Use with UL Listed, ULC Listed and FM Approved Systems P/N: 486500-01 ELECTRIC CONTROL HEAD, PART NO. 486500-01 IS RATED FOR USE IN HAZARDOUS (CLASSIFIED) LOCATIONS CLASS 1, DIV. I, GROUPS C, D AND CLASS II, DIV. II, GROUPS E, F, G BETWEEN -40F AND 140F. USE CONDUIT . SEAL WITHIN 18 IN. (45cm) OF THIS DEVICE. =-F-2A ON - 112'-14 NPT CONDUIT CONNECTION VG-LEADS S .VVIVL PlO I 1.25-18 UNEF-2B CONNECTION NOTES This control head is polarized. Improper wiring will result in operational failure of this device. TECHNICAL DATA Voltage: 24 Vdc Current: O.2AContinuous Draw - 0 FM-200 is a registered trademark of the Great Lakes Chemical Corporation A WARNING Electric Control Head, PIN 486500-01, is designed for installation directly on 487 and KNC Series Halon and FM-200 ECS Series valves only. This control head must not be installed on any other type of Halon or FM-200 cylinder valve, nitrogen valve, carbon dioxide cylinder valve, FE-13 cylinder valve or stop (directional) valves. Installation of this control head to any other device (e.g., pressure operated control head) will result in failure of the device to operate. This literature is provided for informational purposes only. KIDDE-FENWALtNC. assumes no Kidde Fire Systems responsibility for the products suitability for a particular application. The product must be prop- 400 Main Street lerly applied to work correctly. I Ashland, MA 01721 USA If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 Tel: (508) 881-2000 Fax: (508) 881-8920 K-90-8017 04/02 ©2002 Kidde-Fenwal Inc. Printed in USA http://www.kiddefiresystems.com In.-Line Releasing Device Installation Instructions jr-Kidde Fenwal Effective: November 2004 DESCRIPTION The In-Line Releasing Device, PIN 06-220023-001, is used to make a single-or dual-solenoid releasing circuit power limited. See Figure 1. Figure 1. In-Line Releasing Device SUPPLIED PARTS In-Line Releasing Device, P/N 06-220023-001 REQUIRED TOOLS No. 2 Flat-Head Screwdriver. Small Flat-Head Screwdriver. PROCEDURE 1; The tn-Line Releasing Device is polarity-sensitive and must be connected as shown in Figure 2 for a single- solenoid circuit or as shown in Figure No. 3 for a dual- solenoid circuit. The red lead of the In-Line Releasing Device must be connected to the field wiring from Terminal I of the fe- leasing circuit. The black lead must be connected to the control head or solenoid valve. Use wire nuts to connect the In-Line Releasing Device to field wiring and leads from control heads and sole- noid valves. Control Head for Agent Storage Red Red Black Container or <neReleasing Device U'7 Black Solenoid Valve for Sprinkler System Release- Combo- Circuit f T : JUNCTION BOX (enlarged for clarity) Note: Junction box for In-Line Releasing Device must be close nippled to control head or enclosure for solenoid valve. Figure 2. Single-Control-Head or -Solenoid Releasing Circuit C Release-Circuit Fln-Line __________ Terminals Black Control Head for Agent Storage Red Container or ReleasingDeic/ Black Solenoid Valve for Sprinkler System Red Black rVIn-Line Rel.easin9Devi) Control Head for Agent Storage Red Container JUNCTION BOX .=:::==cj:::I:J or (enlarged for clarity) Black Solenoid Valve for Sprinkler System Note: Junction box for In-Line Releasing Device must be close nippled to control head or enclosure for solenoid valve. Use separate junction boxes when control heads or solenoid valves are remote from each other. Figure 3. Dual-Control-Head or -Solenoid Releasing Circuit S Kidde-Fenwal is a registered trademark of Kidde-Fenwal, Inc h1s literature is provided for informational purposes only. KIDDE-FENWAL,INC. assumes no sponsibility for the product's suitability bra particular application. The product must be prop- erty applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KtDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 06-236541-001 RevAA ©2004 Kidde-Fenwal Inc. Printed in USA Kidde Fenwa l Kidde-Fenwal, lnc,D 400 Main StreetiTJ Ashland, MA 01721 U.S.A.D www.kidde-fenwal.com FM-200® Component Description 180 Degree Pendant Nozzle gKiddeFire Systems Effective: April 2002 K-90-2150 FEATURES For use with UL, ULC and FM Approved Systems • See Kidde® Manual 90-FM200M-021 for USCG Approval P/N: 90-19401X-XXX METAL STAMP X-XXX (DASH NO.) IN .093 .031 HIGH CHARACTERS ON ANY FLAT 180 DEGREE NOZZLE Pipe Size A B C D 1/2" (12.20mm) 1.250" (31.75mm) 1.250" (31.75mm) 1.687 (42.84mm) 2.000 (50.80mm) 3/4' (19.05mm) 1.500" (38.10mm) 1.375" (34.92mm) 1.950" (48.89mm) 2.296" (58.31 mm) (25.40mm) 1.750 (44.45mm) 1.562' (39.67mm) 2.218" (56.33mm) 2.671" (67.84mm) 1-1/4" (31.75mm) 2.250" (57.15mm) 1.750' (44.45mm) 2.656 (67.46mm) 3.250" (82.55mm) 1-1/2" (38.10mm) 2.250" (63.50mm) 1.950" (48.89mm) 2.950" (74.93mm) 3.625" (92.07mm) (50.80mm) 3.000' (76.20mm) 1.968" (49.98mm) 2.875" (73.02mm) 3.656" (92.86mm) Note: A selection of orifices are available for each nozzle size. Consult your Kidde® design and installation manual for details. in FM-200 is a registered trademark of the Great Lakes Chemical Corporation. w This literature is provided for informational purposes only. KIDDE-FENWALINC. assumes no responsibility for the products suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KIDDE-FENWAL INC.. Ashland, MA 01721. Telephone: (508) 881-2000 K-90-2150 04/02 02002 Kidde-Fenwal Inc. Printed in USA Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://www.kiddefiresystems.com FM-200® Component Description Kidde Fire Systems Warning Nameplate (FM-200) Effective: April 2002 K-90-9030 FEATURES For Use with UL Listed, ULC Listed and • See Kidde® Manual 90-FM200M-021 for FM Approved Systems USCG Approval P/N: 06-231865-739 10.000 0.063 0.340 - 9.360 [0.340 WARNING THIS AREA IS PROTECTED BY 0.062 FM-200 EXTINGUISHING 5,000 5 SYSTEM. DO NOT ENTER WITHOUT 4.360 AUTHORIZATION DURING OR ___ • AFTER DISCHARGE 0.281 .005 DIA. TYP. 4 HOLES MATERIALS Aluminum Type 1100—H14, 0.032 ± 0.003 Thick. All Letters to be 48 pt., Alternate Gothic #2, Etched 0.003 to 0.005 and Filled in With Red Chip Proof Enamel Color No. 21105 per Fed. Stc. 595 Finish: One Coat Clear Lacquer Both Sides 0 FM-200 is a registered trademark of the Great Lakes Chemical Corporation This literature is provided for informational purposes only. KIDDE-FENWALINC. assumes no Kidde Fire Systems responsibility for the products suitability for a particular application. The product must be prop- I . 400 Main Street lerly applied to work correctly. I Ashland, MA 01721 USA I If you need more information on this product, or it you have a particular problem or question, I contact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 Tel: (508) 881-2000 Fax: (508) 881-8920 K-90-9030 04/02 ©2002 Kidde-Fenwal Inc. Printed in USA http://www.kiddefiresystems.com KIDDE Welcome to the world of FENWAL Fire Protection! . KIDDE-FENWAL AEGIS Fire Control Panel (This Calculation Form is taken from Appendix A' of the AEGIS Installation, Operation and Maint. Manual) Date: 11-Feb-09 Project: SIERRA WIRELESS 2200 Faraday Ave. Carlsbad, CA 92009 Starlab Anechoic Chamber BATTERY CALCULATIONS DEVICE QUANTITY Standby Current Load Total Standby Current Load Alarm Current Load Total Alarm Current Load CONTROL PANEL: Main Control Panel 1 0.1 amp 0.1 amp 0.24 amp 0.24 amp Auxiliary Power Output 0 1 amp 0 amp 1 amp 0 amp MCP Programmable Relay 2 0 amp 0 amp 0.02 amp 0.04 amp LED Display Module 0 0 amp 0 amp 0.04 amp 0 athp FIELD DEVICES: 15 cd Horn/Strobe 1 0 amp 0 amp 0.067 amp 0.067 amp 75 cd Horn/Strobe 0 0 amp 0 amp 0.142 amp 0 amp 75cd Ceiling Strobe 0 0 amp 0 amp 0.119 amp 0 amp Sync Module 0 0 amp 0 amp 0.017 amp 0 amp MT Horn 0 0 amp 0 amp 0.033 amp 0 amp 2-Wire Ionization Smoke Detector 0 0.00007 amp 0 amp 0.001 amp 0 amp 2-Wire Photoelectric Smoke Detector 3 0.00007 amp 0.00021 amp 0.001 amp 0.003 amp Detection Circuits 1 & 2 2 0 amp 0 amp 0.07 amp 0.14 amp Contact Type Heat Detectors 0 DH-60 (2W) Duct Detectors 0 0 amp 0.00007 amp 0 amp 0 amp 0 amp 0 amp 0 amp 0 amp Agent Release Solenoid 1 0 amp 0 amp 0.2 amp 0.2 amp Deluge Release Solenoid 0 0 amp 0 amp 0.7 amp 0 amp Aegis Control Panel Capacity (Amperage rating of Power Supply): 4 amp r Total System Current Demand: 0.69 am Total amps used in Standby: 0.10021 am Total System Current Demand must not exceed Control Panel Capacity Total amps required for 24 Hours Standby: 2.40504 AH Total Amps required for 5 mm. of alarm: 0.058 AH Total Backup Battery Required: 2.46304 AH Total Backup Battery Provided: 12 AH 20% Derated Battery: 9.6 AH Total Backup Battery Reserved: 7.13696 AH Includes relays activated during pre-alarm conditions Q SIERRA WIRELESS o Gauge at OOhms 0 2200 FARADAY AVE. 10 Gauge at 1.02 Ohms AEGIS CONTROL PANEL M84424B 12 Gauge at 1.62 Ohms 6530 Actuator Circuit #1. 14 Gauge at 2.60 Ohms 4110 DC Method 16 Gauge at 4,10 Ohms 2580 Voltage Drop Calculations . 18 Gauge at 6.50 Ohms 1620 STARLAB ANECHOIC CHAMBER , . 20 Gauge at 10.40 Ohms 1020 . - . 22 Gauge at 16.40 Ohms 640 Z4Gauä1 26.20 -Ohms- 434 Node Unit Unit Total Cond AWG Ohms Per Voltage Percent Reference Volt Amps Amps Feet Size ' Foot Drop Volt Drop ACTU-1 24 0.2000000 0.2000000 10 14 0.0052 0.0105109 0.0438% Total Percentage Amps Conductor Voltage Drop Voltage Drop Totals . 0.200 10 0.01051 0.0438% 2/11/096:49 AM Page 1 of 1 WIRELESS 0 Gauge at 0 Ohms 0 O SIERRA 2200 FARADAY AVE. 10 Gauge at 102 Ohms AEGIS CONTROL PANEL 12 Gauge at 1.62 Ohms 6530 Indicating Circuit #2 14 Gauge at 260 Ohms 4110 DC Method 16 Gauge at 4,10 Ohms 2580 Voltage Drop Calculations 18 Gauge at 6.50 Ohms 1620 STAR-LAB ANECHOIC CHAMBER 20 Gauge at 1040 Ohms 1020 22 Gauge at 1640 Ohms 640 24 Gauge at 26.20 Ohms 404 Node Unit Unit Total Cond AWG Ohms Per Voltage Percent Reference Volt Amps Amps Feet Size Foot Drop Volt Drop B-IND 1 24 0.0670000 0.0670000 5 14 0.0052 0.0017606 0.0073% Total Percentage Amps Conductor Voltag Drop Voltage Drop • Totals 0.067000 5 0.00176 0.0073% I S S 2/11/096:51 AM Page 1 o I WIRELESS O Gauge at 0 Ohms 0 • SIERRA 2200 FARADAY AVE 10 Gauge at 102 Ohms AEGIS CONTROL PANEL 12 Gauge at 1.62 Ohms 6530 Initiating Circuit 91 14 Gauge at 260 Ohms 4110 DC Method 16 Gauge at 4.10 Ohms 2580 Voltage Drop Calculations 18 Gauge at 6.50 Ohms 1620 STARLAB ANECHOIC CHAMBER 20 Gauge at 1040 Ohms 1020 22 Gauge at 1640 Ohms 640 24 Gaugeat, 26.20 Ohms 404 Node Unit Unit Total Cond AWG Ohms Per Voltage Percent Reference Volt Amps Amps Feet Size Foot Drop Volt Drop P-1 24 0.0000700 0.0001400 5 14 0.0052 0.0000037 0.0000% P-3 24 0.0000700 0.0000700 15 14 0.0052 0.0000055 0.0000% Total Percentage Amps Conductor Voltage Drop Voltage Drop Totals 0.000140 20 0.00001 0.0000% S C 2/11/096:51 AM Page lot I WIRELESS .SIERRA O Gauge at 0Ohms 2200 FARADAY AVE. 10 Gauge at 1.02 Ohms = AEGIS CONTROL PANEL 12 Gauge at 1.62 Ohms 6530 Initiating Circuit 92 14 Gauge at 260 Ohms 4110 DC Method 16 Gauge at 4.10 Ohms 2580 Voltage Drop Calculations 18 Gauge at 6.50 Ohms 1620 STARLAB ANECHOIC CHAMBER 20 Gauge at 1040 Ohms 1020 22 Gauge at 16.40 Ohms 640 24 Gauge.at 26.20 -Ohms 404 Node Unit Unit Total Cond AWG Ohms Per Voltage Percent Reference Volt Amps Amps Feet Size Foot Drop Volt Drop P-2 24 0.0000700 0.0000700 10 14 0.0052 0.0000037 0.0000% Total Percentage Amps Conductor Voltage Drop Voltage Drop Totals 0.000070 10 0.00000 0.0000% I S S 2/11/096:51 AM M290CY NDLR Il\ 7M200 PROTECTED AREA 3L1N. CJ C)L'N Mi c i 'H F'ThP flP (Th.-j ' \AFFP ________ \} \f. \.fl /\'L)L1\ \ . Fil \I/ B- -- C !<1 t4l LYJ.* + 5FACF AQuNrD rr PAN[ \ LJL/L :\,jL. .JL 1/2" MI., EMT CONDUIT (TYP) 2-WIRE 14AWG T}-I.HN SOi.JD COPPER CONDUCTOR REFLECTED CEILING PLAN. 5,C-ALE: !4_I1 . I__INDIES (1) PAIR 14 AG THHN SOLID CCATOPPER CONDUCTOR (TYPICAL) / FM-200 15' ""5' . SYSTEM CONTROL iD PANEL 3.9K EOL S ALARM SIGNAL TO IRE ALARM CONTROL PANEL TROUBLE SIGNAL TO FIRE ALARM CONTROL PANEL WIRING END CONNECTION FOR THESE FUNCTIONS BY OTHERS NOTIFICATION ALARM B-IND-1 CIRCUIT NO, 2 EOLD- 3. 9K ACTU-1 EOL fr---- (AEGIS) PROTECTS STARLAB ANECHOIC CHAMBER 10, POINT TO POINT WIRING LAYOUT JO SCAft AEGISTM 9--dw Kidde Fire Systems Conventional Fire Alarm-Suppression Control Unit A UTC Fire & Security Company Effective: March 2007 84-100 FEATURES Agency Approvals • Input and Output FM Approved 3 Detection Circuits FM Approved to ANSI/UL 864, 9th edition 2 Supervisory Circuits FM Approved to ULC-5527-99 1 Manual Release Circuit Other domestic U.S. approvals/listings pending! 1 Abort Input Circuit in-process 3 Notification Appliance Circuits Suppression focused Control Unit 2 Release Circuits Listed for a Wide Range of Suppression Systems 4 Form-C Relays Kidde FM-200, FE13, CO2. 3fWMNovec 1230 • Programmable Relays Fire Protection Fluid, ArgoniteTM, and Halon • Robust Power Supply Clean Agents Kic/de INDTM Dry Chemical & WHDRTM Wet • Elegant User-Interface Chemical Systems • Simple Configuration Sprinkler Supervisory Service • Password Protected Deluge, Preaction, Foam, Foam-Water Systems 0Digital Release Countdown Combination Clean Agent plus Pre-Action System • Battery Voltage and Charging Current Display Built-in Class-A and Class-B Circuitry • Extensive Diagnostics Sophisticated Programmable Notification Appliance • Backwards compatible Circuits • Improved and Enlarged Cabinet Design Independently Programmable Agent Releasing Circuits • 5-Year Warranty with Triple-R Protection DESCRIPTION The Kidde AEGIS is the technologically most advanced Con- : ventional Single Hazard Agent Releasing Unit available to S the Fire-Alarm Suppression industry today. It combines the high quality, system reliability, and flexibility required by modern commercial, high-tech and industrial applications in an aesthetically pleasing and physically robust package. The AEGIS is well equipped to handle all special hazard extinguishing systems due to the high degree of program- ming flexibility, provided and the following full complement of input and output circuits: Three (3) Class A or Class B Detection Circuits Two (2) Class A or Class B SupervisoryCircuits One (1) Class A or Class B Manual Release Circuit One (1) Class A or Class B Abort Input Circuit Three (3) Class A or Class B Notification Appliance Circuits Two (2) Class B Agent Release Circuits Four (4) Form-C Relays S DETECTION CIRCUITS The Detection Circuits can support up to 25 Conventional CPD-705x Ionization Smoke, PSD-715x Photoelectric ,moke, orTHD-705x Heat Detectors each as well as Nor- ally Open contact closure type devices. Two circuits are dedicated to the main suppression function and can be pro- grammed to activate the release circuits by either single- shot or cross-zone input. The user-configuration allows automatic release via detection to be delayed from 0 to 60 seconds in 10-second intervals and also allows a choice of which of the two Agent Release Circuits to activate. The third Detection Circuit is programmable for either Waterfiow or as an independent Detection circuit. When programmed for Waterflow, Notification Appliance Circuits can be programmed as Non-Silenceable as required by certain jurisdictions. SUPERVISORY CIRCUITS The Supervisory Circuits accept Normally Open contact clo- sure type devices such as pressure switches on the agent cylinders or on the water or air pipe network. The system configuration enables the supervisory input to be a partici- pant in the suppression function. For example, low air su- pervisory can be included with detection for release of pre-action systems as required by certain jurisdictions. SUPERVISORY SUPERVISORY 2 1 MANUAL RELEASE AND ABORT CIRCUITS Both the Manual Release and Abort Circuits accept Nor- mally Open contact closure type devices. Activation of the Agent Release Circuits can either be instantaneous or de- layed up to 30 seconds (maximum) upon receipt of Manual Release input Agent release can be temporarily delayed by activating the Abort Circuit. The Abort input can be pro- grammed for 5 modes of operation. These include the UL 10-second mode, the full-delay mode, the IRI mode, the NYC mode, or the abort can be disabled. Aborts cap also be programmed to be applicable for either one or both Agent Release Circuits thereby allowing use with Deluge/Pre-Ac- tion systems. NOTIFICATION APPLIANCE CIRCUITS (NAC) The three Notification Appliance Circuits are rated 1.5 Amps each and accept polarized 24 VDC Notification Appliances. Of the three circuits, NAC1 activates on First Alarm, NAC2 in Pre-Release condition and NAC 3 in Releasing condi- tion. Each circuit is driven independently and is user configurable for 60 BPM, 120 BPM, Temporal, or Continu- ous pattern. The MT and F'S series appliances provide the option to use silenceable horns and non-silenceable strobes on the same NAC. Multiple NAC circuits (connected to audible devices only) programmed with the same master code pattern are synchronized, regardless of any differing starting times that preceded their concurrent operation. The NACs configura- tion includes a user-selectable intelligent synchronization feature which allows a silenceable horn to be shut off while the strobe continues to flash in synchronized fashion. MANUAL WATERFLOWI ABORT RELEASE DETECTOR 3 DETECTOR 2 TROUBLE RELAY 3 RELAY 2 RELAY 1 BAIT OUT AC IN Inj b • 0 .'..' h • Ono 0 0RS2 ' 00 oe TBT T66 Q ) TB5 T84 T83 TB2 13 TB8 \ _/ fJj TB9 — TBI El 13 TB10 r 0 -L Kidde fl Fire Systems JJ TBII Qu, Os'." QAUUTn *iic,isu OWHMMS 0-111"10-111L 0 0---- Q NASREITSI. 0 516TEMTSL COUNTDOWN TINTS IstES) H!IIT812 omost OWNORETS. ONAC,mL O"' EJII.J Qs. Qssisc ONACIREL 0U" QNA 0" ONACNTDL OoTom AC SUPPLY SELECT SWITCH (S6) n M fl /TB1420 TBI5 T816 TBI7 T8I8 111 LcU 120 $TB13 . 3!Fi• 'I DETECTOR I NAC 1 NAC 2 RELEASEI RELEASE AUX NAC3 ARCI ARC2 24VDC Figure 1. Printed Circuit Board (PCB) S BUILT-IN CLASS A AND B CIRCUITRY For the input and NAC circuits, the choice of Class A or Class B supervision is made at site on the board itself by selecting the terminals used for wiring. Neither conversion boards nor additional hardware nor jumper selection is re- quired for this purpose. AGENT RELEASE CIRCUITS (ARC) The two circuits can be programmed for activation by dif- ferent inputs, with independent time delays and abort modes to fire combinations of two of the following releasing de- vices: 1 or 2 Kidde Continuous and Momentary Solenoid Control Heads 1 Kidde Initiator 1 Factory Mutual Group A, B, D, E, F, G, I, J, or K Solenoid In other words, operating in tandem, the two circuits can release: 1 or 2 Control Heads on ARC1 and 1 or 2 Control Heads on ARC2 1 0r2 Control Heads onARCi and 1 Initiator on ARC2 or vice-versa 1 or 2 Control Heads on ARC1 and 1 FM Sprinkler Solenoid on ARC2 or vice-versa 1 Initiator on ARC1 and 1 Initiator on ARC2 1 FM Solenoid on ARC1 and 1 FM Solenoid on ARC2 This configurability is useful for those jurisdictions where the gaseous suppression agent is required to be supple- mented with a pre-action system. TRIPLE-R PROTECTION FOR AGENT RELEASING CIRCUITS (ARC) The two ARCs feature a triple failure redundancy safeguard system to protect them from inadvertent activation by the main microprocessor. The Triple-R system requires that in order to activate an ARC, the main microprocessor issues two release commands of opposing polarity via separate channels an'd that these commands be combined with a third signal from the panel watchdog timer to confirm the microprocessor operation. The Triple-R system ensures that electrical transients or disturbances such as power surges that could interfere with the operation of the main micropro- cessor will not inadvertently activate the connected sup- pression system. The result is a more robust and reliable suppression-focused panel. PROGRAMMABLE RELAYS Of the 4 relays, three are user-programmable for a variety of alarm related conditions and the fourth is a dedicated trouble relay. All relay contacts are rated 3.0 Amps at 30 VDC/120 VAC (resistive). POWER-LIMITED CIRCUITRY All circuits, excluding ARCs are inherently power-limited. Agent Release Circuits, except when firing Initiators, can also be made power-limited by a field located inline releas- ing diode device thereby allowing cost effective installation with all wiring in the same conduit. ROBUST POWER SUPPLY UNIT (PSU) The AEGIS features a universal 120/240 V, 50/60 Hz AC Power Supply Unit with a robust 5.4 Amps of 24 VDC power. Input voltage selection is via a slider switch with no jumper cutting required. The on-board battery charger is able to charge 24 VDC (2 x 12) batteries of capacity up to 68 AH thereby allOwing from 24 hours of supervision plus 5 min- utes of alarm to 90 hours of supervision plus 10 minutes of alarm required by some jurisdictions. AUXILIARY POWER SUPPLY Up to 1 Amp of auxiliary power at 24 VDC is available to power external 4-wire devices such as Flame Detectors, AlarmLine modules, Duct Detectors, etc. ELEGANT USER-INTERFACE The user-interface consists of an array of LED Indicators, Control Switches, a Digital Display, and Buzzer. Over and above the System, Power Supply status, Input circuit Fire and Trouble and Output circuit Trouble LEDs, the AEGIS annunciates its suppression state-of-alarm via three addi- tional Pre-Release, Releasing and Post Release LEDs. Four switches are provided, one each for Acknowledge, Signal Silence, System Reset and Output Disable. The 3-digit dis- play provides a countdown of impending agent release. On command from the user-interlace switches, it also indicates the battery open circuit voltage and charging current. SIMPLE SITE-SPECIFIC CONFIGURATION Accessed via the digital display and user-interface switches, site-specifiá configuration is simple, yet detailed and can typically be performed in a matter of minutes. To prevent unauthorized use, the configuration menu is protected by a user-changeable password. Factory technical support can provide assistance with lost or forgotten passwords. Apart from the input voltage selection performed on both the PSU and main board via a slider switch, no other on- board settings or jumper cuttings are required. EXTENSIVE DIAGNOSTICS Also initiated via the digital display and user-interface switches, the troubleshooting function displays diagnostic codes that assist in determining causes of trouble. A com- plete list of diagnostic codes and their meanings ships fac- tory installed on the inside of the enclosure door for easy reference. BACKWARDS COMPATIBILITY TECHNICAL SPECIFICATIONS (CONT'D) Consistent with previous generation Kidde control equip- ent, the AEGIS is listed to be backwards compatible with full range of Kidde-Fenwal conventional detectors, alarm devices and suppression accessories. Going forward, this will allow older generation panels to be replaced with rela- tive ease. IMPROVED AND ENLARGED CABINET DESIGN The cabinet design allows for easy installation by fitting be- tween the studs of a standard 16 inch studded wall. It is large enough to house two 12 VDC, 12 AH Batteries and provides up to 2 inches (51 mm) of wiring and finger space between the circuit board and the cabinet wall. An optional door design features a factory installed Manual Release and Abort switch for applications with space con- straints. Both switches incorporate guards that prevent their inadvertent activation. Other cabinet options include a flush mounting trim-ring and a dead-front plate required for Canadian applications. TECHNICAL SPECIFICATIONS • Hazards Protected -One • Power Supply • - 120/240 Vac, 50/60 Hz (90 to 264 Vrms, 47 to 63 Hz) AC Main Input - 5.4 Amps at 27 Vdc Output - Battery capacity up to 68 AH @ 24 Vdc - Auxiliary power output rated at 1 Amp at 18.8 - 27.6 Vdc (resettable) Three (3) Detection Circuits - Compatible with up to 25 CPD-705x, PSD-715x, and THD-705x detectors and normally open contact-clo- sure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power limited - DET 1 and DET 2 used for suppression - DET3/WF configurable for detection or waterilow One (1) Manual Release Circuit - Compatible with normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power limited One (1) Abort Circuit - Compatible with normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power-limited Two (2) Supervisory Circuits - Compatible with normally open contact-closure type devices - Configurable as Class A/Style D or Class B/Style B - Supervised for ground faults and open circuits - Power-limited Three (3) Notification Appliance Circuits (NACs) - Compatible with polarized 24 VDC Audio-Visual de-, vices - Rated at 1.5 Amps each - Configurable as Class A/Style Z or Class B/Style Y - Supervised for ground faults, shorts, and open cir- cuits - Power-limited - First Alarm operates NAC 1, Pre-Release operates NAC 2, Releasing operates NAC 3 - Common NAC/ARC output disconnect switch Two (2) Agent Release Circuits - Each compatible with 1 or 2 control heads, or 1 initia- tor, or 1 FM sprinkler solenoid - Circuits electrically capable of simultaneously releas- ing any combination of two of the above devices - Factory configured as Class B/Style V - Supervised for ground faults and open circuits - Non-power-limited. May be power-limited (except with initiators) and supervised for short circuit using inline releasing resistor-diode device - Common NAC/ARC output disconnect switch Four (4) Relays -3 independently programmable, normally de-energized Form-C - 1 dedicated normally energized Form-C Trouble Re- lay - Relay contacts rated 3 Amps at 30 Vdc/1 20 Vac (re- sistive) 0 TECHNICAL SPECIFICATIONS (CONT'D) Enclosure - NEMA 1 rated 18 gauge sheet steel with door - Red color - Suitable for wall and surface mounting - Optional Trim Ring - Optional Dead-Front Panel -Optional door with Manual Release and Abort switches - Dimensions: - with Standard Door: 14-1/4 in. W x 5 in. D 19 in. H (362 mm 127 mmx483mm) - with Switch Door 14-1/4 in. Wx6in. Dx19in. H (362 mm 152 mmx483mm) Environmental Criteria - Indoor/Dry use only - Operating temperature range: 32°F to 120°F (0°C to 49°C) - Humidity: 93 ± 2% RH at 90 ± 3°F (32 ± 2°C) Packaging/Shipping - Enclosure, PCB, and PSU packaged in individual car- tons -Accessories shipped include mounting hardware, bat- tery leads, IOM manual on CD-ROM, operating in- struction sheet, and EOL resistor kit - Order inline releasing resistor-diode device (if required) and batteries separately ORDERING INFORMATION DESCRIPTION N PART UMBER Kidde AEGIS Control Unit 84-732001-001 Kidde AEGIS Control Unit with Switches 84-732001-201 In-Line Releasing Diode (10K) Kit 06-220023-001 Trim Ring 76-600000-007 Dead-Front Panel* 06-236725-001 Battery Enclosure 76-100010-001 Kidde AEGIS Conventional Fire Alarm-Suppression Control Unit IOM 06-236.716-001 Manual Kidde AEGIS Users CD 06-236727-001 *For Canadian applications, order Control Unit and Dead-Front Panel separately. I S Kidde is a registered trademark of Kidde-Fenwal, Inc. AEGIS and Gemini are trademarks of Kidde-Fenwal, Inc. FM-200 is a registered trademark of Chemtura. FE-13 is a registered trademark of DuPont. 3MTMNovecTM 1230 Fire Protection Fluid is a trademark of 3M. Argonite is a registered trademark of Ginge Kerr. This literature is provided for informational purposes only. KIDDE-FENWAL.INC. assumes no responsibility for the products suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question. contact KIDDE-FENWAL INC.. Ashland, MA 01721. Telephone: (508) 881-2000 84-100 3/07 ©2007 Kidde-Fenwal Inc. Printed in USA For detailed installation, operation, and configuration infor- mation, refer to the Kidde AEGIS Conventional Fire Alarm- Suppression Conventional Uhit Installation, Operation, and Maintenance Manual P/N 06-236716-001. idde Fire Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 fax: 508.881.8920 www.kiddefiresystems.com List of Agency Listed Compatible Devices S APPENDIX B LIST OF AGENCY LISTED COMPATIBLE DEVICES B-i DETECTORS AND BASES Table B-i. Detectors and Bases Device Model Part Number Ionization Smoke Detector CPD-7051 70-510000-001 Ionization Detector Duct Head CPD-7051D 70-510000-060 Advanced Ionization Smoke Detector CPD-7054 70-540000-001 Advanced Ionization Detector Duct Head CPD-7054D 70-540000-002 Photoelectric Smoke Detector PSD-7 155 71-550000-001 Photoelectric Detector Duct Head PSD-7155D 71-550000-060 Photoelectric Smoke Detector PSD-7155P 71-550000-002 Photoelectric Detector with 135°F Sensor P5P7156 71-560000-001 Advanced Photoelectric Smoke Detector PSD-7157 71-570000-001 Advanced Photoelectric Detector Duct Head PSD-7 157D 71-570000-002 Electronic 135°F Fixed with 15°F ROR Heat Detector THD7052 70-520000-001 Electronic 135°F Fixed Temp Heat Detector THD7053 0-530000001 2-Wire Detector Base 2WB 70-501000-001 2-Wire Detector Base 2WRLT 70-501000-002 2-Wire Detector Base 2WRB 70-501000-005 2-Wire Relay Module 2WRM 70-500000-004 2-Wire Duct Housing DH-60-2W 70-600000-200. 2-Wire Duct Housing with CPD-7051D 0 DH-60-2CPD 70-600000-251 2-Wire Duct Housing with CPD-7054D DH-60-2ACD 70-600000-254 2-Wire Duct Housing with PSD-7155D DH-60-2PSD 70-600000-255 2-Wire Duct Housing with PSD-7157D DH-60-2APD 70-600000-257 P/N 06-236716-001 8-1 March 2007 I I I List of Agency Listed Compatible Devices Table B-2. Releasing Solenoid Wire Length (ft.) Device I (Mm.) Amps Resistance (Max.) Ohms On Time 12 AWG 4 AWG 16 AWG 18 AWG Max. Number per Circuits Agency 890181 2.4 10 Momentary 300 200 120 - 1 or 2 UL, FM 895630 2.0 12 Momentary 300 200 120 - 1 or 2 UL, FM 899175 2.20 10.8 Momentary 300 200 120 - 1 or 2 UL, FM 48650001 0.24 103 Steady 3000 2000 1200 800 1 or 2 UL, FM 06-118329-001 0.225 108 Steady, 3000 2000 1200 800 1or2 FM 06-118384-001 0.52 46 Steady 1440 760 480 340 1 or 2 UL 38-509834001 0.632 38 Steady 1050 550 330 240 1 or 2 UL, FM 38-509837-001 0.4 60 Steady 2300 1460 915 570 1 or 2 UL, FM 81-100000-001 0.44 59 Steady 2300 1460 915 570 1or2 UL,FM 87120099001* 2 12 Momentary 360 240 140 - 1 or 2 UL, FM 87120099012* 2 12 Momentary 360 240 140 - 1 or 2 897494-000 1.5 14.2 Steady 380 240 150 - 1 UL, FM 897494-530 1.5 14.2 Steady 380 240 150 - 1 UL, FM 90487100001* 2 12 Momentary 360 240 140 -- 1 or 2 UL, FM FM Group A 0.458 52 Steady 1440 760 480 340 1 FM Group B, D 0.7 34 Steady 940 500 300 220 1 FM FM Group E, G 0.42 57 Steady 1570 760 525 370 1 FM FM Group F Skinner 24 Vdc, 22 Watt Solenoid 7312BN4TNLVNOC322C2 1 FM FM Group I Victaulic 24 Vdc, 8.7 Watts, 364 mA series 753-E Solenoid 1 FM FM Group 3 Viking Model No. 11591, 11592, 11595, and 11596, 24 Vdc, 10 Watts 1 FM FM Group K Viking Model No. 11601, 11602, and 13215, 24 Vdc, 9 Watts 1 FM * Must be used in conjunction with Microswitch P/N 87-120039-001 for momentary operation. Table B-3. Initiator-Based Releasino Devices Device I (Mm.) Amps I Resistance (Max.) Ohms On Time I Max. Number per Circuits Agency 83-131025-001 * 3 Momentary 1 * The maximum circuit resistance for this device must be 10 ohms, regardless of the number used. The firing current will be 2.5 Amps. Table B-4. Miscellaneous Devices Device Oleceiving Model Number Supplier/Mfg. Units for Central Station 5104 Silent Knight March 2007 B-2 P/N 06-236716-001 ED Advanced Photoelectric Smoke Detectors Models PSD-7157 & PSD-7157D 70.02 FEATURES Approvals/Listing . US and Canadian UL Listed (cULus) FM Approved CSFM Approved NYC MEA Accepted (pending) Dual Ionization Chamber Technology Nominal Sensitivity PSD-7157: 3.25% per foot Obscuration PSD-71570: 2.40% per foot Obscuration Sensitivity Measurement/Testing Wireless Measurement in %/ft Obscuration Remote and Local Functional Test Capability Wide Range of Input Voltage 10.2 to 36.8 VDC Low Current design Dual Response LEDs allow 360-degree viewing Trouble Indication Low Profile Appearance using Surface Mount Technology Electrically and Mechanically Compatible with all Fenwal Smoke and Electronic Heat Detectors and Bases Interchangeable 2-Wire and 4-Wire Bases Universal Relay Modules Non Polarized Locking Feature for Vandal Resistance Fine Mesh Insect Screen EMI and RFI Resistant DESCRIPTION The Fenwal Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors respond to a broad spectrum of both flaming and smoldering fire conditions. The Detectors have advanced solid-state, low-voltage, surface-mount circuitry and are designed for 2-Wire and 4-Wire installation using the appropriate Detector base. The characteristic 360-degree detector design permits smoke entry from any direction. A unique sensing chamber de- sigh permits the operation of the Models PSD-7157 and PSD- 7157D in open areas with air velocities from 0 t 300 fpm and 0 to 4000 fpm respectively. The Model PSD-7157D is also suitable for duct housing applications in air velocities from 500 to 4000 fpm. The Detectors are designed for open area/duct housing applications per UL268/UL268A and maybe installed in systems intended for Releasing Device Service through use of compat- ible Fire Alarm Control Panels. Two Red Light Emitting Diodes are located diametrically oppo- site each other so as to allow 360-degree viewing. Both LEDs continuously indicate the operating condition of the Detector. During standby, the LEDs flash once every six seconds. During alarm, both LEDs light steady at full brilliance. A double flash every six seconds indicates a detector with a sensitivity thresh- Effective: January 2006 old outside acceptable limits. A unique gated output circuit de- sign provides improved stability and transient suppression. Spe- cial signal processing techniques verify the presence of smoke before the detector will alarm. A fine mesh insect screen protects the chamber area and is used to avoid potential nuisance alarms. The detector head is installed into the base with a simple twist- lock action. A locking feature is provided for vandal resistant se- curity. Table 2 lists the Technical Specifications for Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors. CONTROL UNITS The Models PSD-7157 and PSD-7157D Detectors are designed for operation with control units and releasing devices having spe- cific voltage and current characteristics that are compatible with the detector circuitry. The Detectors are compatible with the Fenwal control units and interface modules listed in Table 1. DETECTOR BASE OPTIONS The Models PSD-7157 and PSD-7157D can be used with the detector base options and accessories in Tables 3 and 4. Various base options are available to provide auxiliary relay and/or re- mote indication and remote test feature. The Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors may be interchanged with other Fenwal Series THD- 705X Electronic Heat Detectors and Series CPD-705X Ionization Smoke Detectors when using multifunction base configuration. SPACING (OPEN AREA LOCATION) The Models PSD-7157 and PSD-71570 Detectors are listed to be installed on maximum 30 foot (9.1 m) centers, typically on smooth ceilings up to 15 feet (4.6 m) high and will operate with minimum air circulation. Resultant maximum 900 square foot (83.6 m2) spacing may be used as a reasonable guide for comparable applications. Where special conditions exist (ceiling obstructions, high air exchange rates, etc.), reduced spacing must be used to achieve adequate protection. Computer rooms and other such installations may re- quire spacing with a maximum of 200 square feet (18.6 m2) due to high air exchange rates. Detectors should not be located in areas with excessive exhaust fumes, kitchen areas, near fireplaces or furnace rooms and within three (3) feet of air supply ducts or air diffusers. For additional information, consult the Fenwal Automatic Fire Detection Application Engineering Manual MC402, NFPA-72 and the local Authority Having Jurisdiction. WIRING DIAGRAMS For detailed wiring diagrams with Fenwal 2- and 4-wire bases, please refer Fenwal Document 70.104 INSTALLATION Detector bases are directly mounted on the electrical junction boxes (3", 3.5" and 4" octagonal, 3" round or 4" square) without the need for any mechanical adapter required. Refer Fenwal Document 70.104 for additional details. The detector bases also include a locking feature that prevents removal of the detector without use of a tool. TESTING AND MAINTENANCE Testing shall be performed upon installation of the detector and once a year thereafter as stated in NFPA-72 latest edition. ARCHITECT/ENGINEER SPECIFICATIONS The contractor shall furnish and install where indicated on the plans, UL268/UL268A listed Photoelectric Smoke Detectors, Fenwal Models PSD-7157 and PSD-71570. The combination detector head and twist-lock base shall be UL Listed compatible with a UL Listed fire alarm control unit. The Models PSD-7157 and PSD-7157D Photoelectric Smoke Detectors shall share in- terchangeable bases with the CPD-7054 and CPD-70540 Ion- ization Smoke Detectors and the THD-7052 and THD-7053 Heat Detectors. The Fenwal Models PSD-71 57 and PSD-71 57D Photoelectric Smoke Detectors shall have two Red LEDs located diametrically opposite each other so as to allow 360-degree viewing. The LEDs shall continuously indicate the operating condition of the Detec- tor. During standby, the LEDs shall flash once every six sec- onds. During alarm, both LEDs shall light steady at full brilliance. If the sensitivity of the detector drifts outside acceptable limits, the LEDs shall double flash every six seconds. The detector may be reset by actuating the control panel reset switch. The vandal- resistant security locking feature shall be used in those areas as indicated on the drawings. The locking feature shall be field re- movable when not required. It shall be possible to measure the sensitivity of the Fenwal Mod- els PSD-7157 and PSD-71 57D Photoelectric Smoke Detectors from a distance of up to 15 feet (4.6 m) without removal from the base. Measurement shall be accomplished with a wireless infra- red Fenwal Sensitivity Tester (DST-003) allowing direct measure- ment in percent per foot obscuration. Sensitivity measurement techniques requiring wiring between the Detector-Base combi- nation and the Tester shall not be acceptable. It shall also be possible to perform afunctional test of the detector without the need for generating smoke. The Fenwal Models PSD-7157 and PSD-71570 Photoelectric Smoke Detectors shall operate over an input voltage range from 10.2 to 36.8 VDC. Voltage and RE transient suppression tech- niques to withstand up to 20 volt/meter shall be employed to minimize susceptibility to false alarms. Detector sensitivity shall be checked within one year of installa- tion and every alternative year thereafter as stated in NFPA 72. Refer Fenwal Documents 70.103 and 70.104 for details on using the Infrared Wireless Sensitivity Tester Model DST-003. The tester provides direct readout in percent per foot obscuration from a distance of 15-feet without removing the detector from its base. A go/no-go test can be performed using a test magnet. The recommended requirement for detector maintenance con- sists of an annual cleaning of dust from the detector head by using the suction of a vacuum cleaner. Cleaning programs should be geared to the individual environment in conformance with NFPA 2. ACAUTON Do not attempt disassembly of the factory sealed detector. This assembly is sealed for your protection and should not be opened for servicing. Opening of the detector will void its warranty. C SPARE PARTS The Models PSD-7157 and PSD-7157D Detectors are factory repairable only and have no field serviceable spare parts. No field repair should therefore be attempted. For service, return detector head intact to Fenwal. Table 1. Control Unit Control Unit Compatibility Identifier Number Maximum Detectors per Loop 2210/2212 C10FEI 40 2410/2412 C10FEI 40 2320 C30FE1 15 3210 ZDMOI, ZDMDOI, VZMOI 25 3220 C32FEI 40 Note: Please refer to Document 70.63 for compatiblfty with other Fire Alarm Control Panels. 2 S S Table 2. Technical Specification Model Number PSD-7157 PSD-7157D Part F'&imber 71-570000-001 71-570000-002 Detection Photoelectric Photoelectric Approvals cULus, FM, CSFM, MEA-NYC cULus, FM, CSFM, MEA-NYC (I Compatibility I.D. P55FE1 P55FEI Listed Spacing 30 ft. (9.1 m) centers or 900 sq. ft. (83.6 nf) 30 ft. (9.1 m) centers or 900 sq. ft. (83.6 m2) Nominal SensitMty 3.25% + 0.45% - 1.78% per foot Obscuration 2.40% + 0%-i4% per foot Obscuration Standby Voltage (VDC) Using 2WB 10.2 (036.8 10.2 to 36.8 Using 4WRB 16.8 to 36.8 16.8 to 36.8 Maximum Current .Standby 70 p 70pA Alarm 100mA 100 m Response Indicators Quantity 2 external LEDs 2 external LEDs Standby Condition One flash every 6 seconds One flash every 6 seconds Abnormal Sensitivity Double flash every 6 seconds Double flashevery 6 seconds Alarm Condition Steady at full brilliance Steady at full brilliance Operating Environment Standby Temperature 32° to 120°F (0 to 49°C) 32° to 120°F (0 to 49°C) Storage Temperature -20 to 180°F (-29° to 82°C) -20 to 180°F (-291 to 82°C) Relative Humidity 0 to 93% Non-condensing 0 to 93% Non-condensing Air Velocity Open Area 0 to 300 fpm (0 to 1.5 m/s) 0 to 500 fpm (0 to 2.5 m/s) Duct Housing N/A 500 to 4000 fpm (2.5 to 20 m/s) Altitude Up to 7,500 feet (2,286 m) Up 107,500 feet (2,286 m) Physical Characteristics Material and Finish High-impact, flame-retardant plastic, off white High-impact, flame-retardant plastic, off white Weight 35.3 oz. (hOg) w/o base 35.3 oz. (11 09) w/o base Dimensions Detector Height 1.38 in (35 mm) 1.38 in (35 mm) Detector Diameter 3.90 in (99 mm) 3.90 in (99 mm) Base Height 0.43 in (11 mm) 0.43 in (99 mm) Base Diameter 5.90 in (150 mm) 5.90 in (150 mm) 0 Table 3. Detector Base Options Part Number Model CID Description 70-501000-001 2-WIRE FE51A 2-W Base. Connects to circuit via screw terminals 70-501000-002 2WRLT FE52A 2-W Base W/ Remote LED & Test capabilities. Connects to detection via screw terminals. Minimum Alarm Current 15 mA @ 24 VDC. 70-501000-005 2WRB FE55A 2-W Base WI 2WRM, Remote LED & Test capabilities. Connects to detection circuit via pigtail leads. Minimum Alarm Current 19 mA @ 24V0C 70-501000-101 4WRB N/A 4-W Base WI 4WRM, Remote LED & Test capabilities. Connects to detection circuit via pigtail leads. Minimum Alarm Current 35 mA @ 24VDC 70-500000-004 2WRM N/A SPDT Relay for 2WRB Bases. Contacts rated 1.0 A, 30 VDC/ 0.5 A, 125 VAC 70-500000-102 4WRM N/A SPDT Relay for 4WRB Bases. Contacts rated 1.0 A, 30 VDC /0.5 A, 125 VAC 70-501000-003 MA-001 MAFEI Mechanical Adapter allows CPD-705X & PSD-715X Detectors to physically connect to Base P/Ns 70-201000-001, -002, -003, -005 & DI-I-22 Table 4. Ordering Information Part Number Model Description Detector Heads - Ionization Smoke 70-540000-001 CPD-7054 Ionization Advanced Smoke Detector (cULus) 70-540000-002 CPD-7054D Ionization Advanced Smoke Detector (cULus) Detector Heads - Photoelectric Smoke 71-570000-001 PSD-7157 Photoelectric Advanced Smoke Detector (cULus) 71-570000-002 PSD-7157D Photoelectric Advanced Smoke Detector (cULus) Detector Heads - Heat 70-520000-001 THD-7052 135°F Fixed Heat Detector, 15°F Rate of Rise (cULus) 70-530000-001 THD-7053 135°F Fixed Heat Detector (cULus) Detector Bases 70-501000-001 2-WIRE 2-Wire Standard Base 70-501000-002 2WRLT 2-Wire Base with Remote LED & Test Capabilities 70-501000-005 2WRB 2-Wire Base with Auxiliary Relay, Remote LED & Test Capabilities 70-501000-101 4WRB 4-Wire Base with Auxiliary Relay, Remote LED & Test Capabilities 70-500000-004 2WRM Spare 2-Wire Relay Module 70-500000-102 4WRM Spare 4-Wu-e Relay Module Detector Accessories 06-117883-001 Test Magnet 29-116788-001 EOL Supervisory Relay 70-200000-911 RA-911 Remote Alarm Indicator 70-200000-914 RA-914 Remote Alarm Indicator with Smoke Detector Test Switch 70-500000-003 DST-003 Advanced Handhold Wireless Smoke Detector Sensitivity Tester 70-501000-003 MA-001 Mechanical Retrofit Adapter is provided for informational purposes only. KIDDE-FENWAL,lNc. assumes nol TENWALliterature Iresponsibility for the products suitability for a particular application. The product must bel Protection Systems properly applied to work correctly. I If you need more information on this product, or if you have a particular problem or question, Icontact KIDDE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 KIDDE-FENWAI, INC. 400 MAIN STREET, ASHLAND, MA 01721 70.02 Rev. AA ©2006 Kidde-Fenwal Inc. Printed in USA TEL (508)881-2000 FAX: (508) 881-8920 w.fenwalfire.coni S S • Approximate Part Number Description Shipping Weight Abort Station without ut 2 1b. Backbox 878752-02 Abort Station with 3 lb. Backbox 296105 Backbox 1 lb. I 1.70" (43.18 mm) (77.47 mm) - 2.25 (57.15 mm) S Model 878752 Suppression System Abort Station Kidde Fire Systems Effective: March 2002 1-152 FEATURES • Sized for Double Gang Box UL Listed, File #S3743 • Large Yellow Push Button Switch Flush or Surface Mount • One Normally Open Contact DESCRIPTION The Kidde Model 878752 Abort Station features a large, S.. .. - easy-to-operate abort push button. The momentary type switch is very easy to see due to its highly visible yellow .1. color. The abort station stainless steel faceplate is clearly labelled with operation procedures—eliminating indecision - - and hesitation. The Backbox is painted with red enamel and is provided with four 1/2" knockouts. The pre-drilled and tapped mount- ing tabs allow for easy attachment of the abort station TECHNICAL SPECIFICATIONS Electrical Ratings: ... One N.O. momentary contact rated 2.5 Amps @ 120 Vdc. Ambient Temperature: -13°Fto158°F (-25°C to 70°C) 45 Terminals: _ _ (1 14 mm) Captive screws and saddle clamps accept 14 AWG to 24 AWG wire. J PUSH/HOLD Mounting: 4.5- Q Four 6-32 x 1/2" mounting screws included. (1114 mm) ORDERING INFORMATION SUPPRESSION SYSTEM ABORT KIDDIE 19 S This literature is provided for informational purposes Only. KIDDE-FENWAL,INC. assumes no responsibility for the product's suitability for a particular application. The product must be prop- erly applied to work correctly. If you need more information on this product, or if you have a particular problem or question, contact KlODE-FENWAL INC., Ashland, MA 01721. Telephone: (508) 881-2000 -152 03/02 ©2002 Kidde-Fenwal inc. Printed in USA Figure 1. Dimension Details Kidde Fire Systems 400 Main Street Ashland, MA 01721 USA Tel: (508) 881-2000 Fax: (508) 881-8920 http://www.kiddefiresysterns.com Manual Pull Stations Series 3300 4000 it, Kidde Fire Systems. A UTC Fire & Security Company Effective: April 2007 FEATURES Exclusive KIDDE® Design Unique Field Labeling for either Fire Alarm or Suppression Applications Dual Action Operation Single Pole or Double Pole Keylock for Reset DESCRIPTION The Kidde® Conventional SPST and DPST Series 3300 Manual Pull Stations are high quality, non-coded alarm initiating devices. The Manual Pull Stations are con- structed of heavy die-cast aluminum for long life and use an internal toggle switch for reliable operation. The SPST Manual Pull Station provides an Single Pole, Single Throw switch with screw terminal connections for wiring to the Fire Alarm/Suppression Control Unit. The DPST Manual Pull Station provides a Dual Pole, Sin- gle Throw switch with screw terminal connections. One set of contacts must be wired to the Fire Alarm/Suppre- sion Control Unit and the other may be used for local or remote annunciation. These Manual Pull Stations are designed for quick, effi- cient response by personnel in an emergency, while the double action PUSH/PULL levers prevent accidental operation. This unit should use a break rod as an indica- tor of operation. The Manual Pull Stations can be mounted in an indoor or outdoor weatherproof backbox (Model SBG-32S or Model SGB-32C) or a North American 2-1/2 in. (64 mm) deep 1-gang box. The Manual Pull Station terminal block accepts 14, 16 and 18 AWG wire. FIRE ALARM OR SUPPRESSION RELEASE LABELING The Kidde Series 3300 Manual Pull Stations have a unique labeling method which provides the installer the greatest amount of flexibility. Seven labels are shipped with each station: FIRE ALARM • FM-200 RELEASE CO2 RELEASE • FE-13 RELEASE FIRE SYSTEMS • HALON-1301 RELEASE RELEASE NOVEC 1230 RELEASE FM Approved cULus Listed for US and Canada Other domestic appiovaisih process Surface and Weatherproof Backboxes Backwards compatible mounting with the B-10 and B-Il These permanent, heavy-duty Lexan® self-adhesive labels are die-cut with raised lettering. During installation, the installer simply chooses the appropriate label, removes the protective backing, and places the label into the space on the top of the station. This flexibility allows installations to be customized for each customer, without the expense of having to carry extra inventory. OPERA TION The dual action Series 3300 manual stations are oper- ated by simply pushing the PUSH bar inwards, allowing the PULL handle to be grasped in a one-handed motion. The handle is then pulled down as far as it will go. If the optional breakrod is installed, it would break at this point. The handle is now locked in place, and is easily visible from up to 50 feet away. The handle is reset by opening the station with the key and placing the handle in the nor- mal upright position. Place the switch actuator in the down position, insert breakrod into cavity beneath handle (if applicable), and re-lock the station. ID SPECIFICATIONS Station Type: Double Action, Non-coded Switch Type: P/N 84-330001-001: SPST P/N 84-330001-002: DPST Switch rating: 2 Amp @ 240 Vac or 125 Vdc Operating Tempera- -40°F to 150°F (-40°C to 66°C) ture Range: Operating Humidity 0-95% RH Range: Construction: Die-cast metal housing Compatible Electrical Indoor: Sheet metal Model SGB- Boxes: 32S Outdoor: Weatherproof Die-cast Model SGB-32C Shipping Weight: 1.12 lbs. (510 g) SGB-325 INTERIOR SURFACE BACKBOX Dimensions: 4.75 in. H x 3.25 in. W x 2.25 in. D is Construction: Steel sheet metal. ORDERING INFORMATION Part Number Description 84-330001-001 Double Action Manual Pull Station with SPST Switch - ships with mounting hardware, 2 keys, I break rod, and label set. 84-330001-002 Double Action Manual Pull Station with DPST Switch - ships with mounting hardware, 2 keys, 1 break rod, and label set. 84-100009-001 SGB-32S Indoor Backbox 84-100009-002 SGB-32C Outdoor Waterproof Backbox 84-100008-002 Pkg. of (12) Breakrods 06-118013-001 Spare Key 06-231866-930 Label Set DIMENSIONS (shown with Fire System Release Label installed) 14164 In. (27 mm) 3-114 In. (83 mm) II 31132 In. Conduit: Two knockouts for 1/2 in. conduit FE connectors, one on top and bottom. 8Y8I 8Y8TI RELEA!%4RELEAeE Mounting: Mounts to the box with (4) 8/32 screws, which ship with each box. PUSH 11 SGB32C WEATHERPROOF SURFACE 4.314 In. (121 mm) PULL BA CKBOX Dimensions: 4.75 in. H x 3.25 in. W x 2.25 in. o Construction: Cast aluminum. Conduit: One threaded opening for 1/2 in. conduit connector. Mounting: Mounts to the box with (4) 8/32 screws and a foam gasket, which ship with each box. S Kidde is a registered trademark of Kidde-Fenwal, Inc. FM-200 is a registered trademark of the Greak Lakes Chemical Corporation. 3M and Novec are trademarks of 3M. FE-13 is a trademark of DuPont. Lexan is a registered trademark of the Genera) Electric Company. This literature is provided for informational purposes only. KIDDE-FENWAL, INC. assumes no responsibility for the products suitability for a particular application. The prod- uct must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or ques- tion, contact KIDDE-FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881-2000. K-84-08 Rev AA D 2007 Kidde-Fenwal Inc. Printed in USA Al or Kidde Fire Systems A UTC Fire & Security Company 400 Main Street Ashland, MA 01721 Ph: 508.881.2000 Fax: 508.881.8920 www.kiddefiresysrems.com C 00 OOPER Wheelock Series MT and MT Strobe Multitone Electronic Appliances [] SERIES MT STROBE MT4-115-WH SERIES MT-12/24 S Description: The Wheelock Series MT and MT Strobe Multitone electronic appliances offer a choice of eight (8) nationally and internationally recognized alerting sounds: Horn, Bell, March Time Horn, Code- 3 Tone, Code-3 Horn, Slow Whoop, Siren or Hi/Lo Tone. The Code-3 Horn and tone patterns are engineered to comply with NFPAIANSI Temporal Pattern specifications without requiring additional equipment. With MT and MT Strobe appliances, one alarm appliance meets most of your signaling needs. The MT strobes can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-81VIC Power Supply with the Wheelock patented Sync Protocol. The MT Strobes are designed for ADA applications while meeting or exceeding the latest requirements of NFPA 72, ANSI 117.1, UFC and UL Standard 1971 as well as meeting ADA requirements concerning photosensitive epilepsy. Each MT and MT Strobe appliance has two installer selective sound output levels: STANDARD dBA and HIGH dBA. Non-strobe versions provide selectable voltage capability in one unit, I2VDC or 24VDC. Strobe versions are specific for either 12VDC or 24VDC and all models may be used with filtered or unfiltered (full-wave- rectified) input voltages. Separate input terminals are available, shunt wires are provided to enable both tone and strobe to operate simultaneously from a single input. The Series MT Multitone Strobe appliances are UL Listed for indoor wall mount applications under Standard 1971 for Signaling Devices for the Hearing Impaired and under Standard 464 for Audible Signaling Appliances. Features: Approvals include: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), New York City, (MEA), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information Designed to meet or exceed ADAINFPNUFC/ANSI Standards and Accessibility Guidelines Complies with OSHA 29, Part 1910.165 Series MT appliances have IN and OUT wiring terminations that accept two #12 to #18 American Wire Gauge (AWG) wires at each terminal. Inputs are polarized for compatibility with standard reverse polarity type supervision One alarm appliance with (8) eight selective signals to provide superior sound penetration for various ambient and wall conditions with two field selectable sound output levels Code-3 Horn and Tone meet ANSI/NFPA temporal pattern for standard emergency evacuation signaling Audible and strobe can operate from a single NAC circuit or from separate NAC circuits with any of the (8) eight audible sounds MT Strobe models are available with Wheelock patented MCW Multi-Candela strobes with field selectable c andela settings at 15/30/75/11Ocd or with single candela 1575cd strobes. The strobes can be synchronized using Wheelock sync modules or power supplies with built in Sync Protocol Selectable input voltage on non-strobe versions. Strobe versions are factory set for either 12 or 24VDC, with wide- Listed voltage range, filtered (DC) and FWR No additional trimplate required for flush mounting For Weatherproof MTWP See Data Sheet S9004 S @OU L -"A MEA APPROVED E5946 15192-E 7135-0785:118 (MT4) 7125-0785:155 (MT) 7fl71'. ATWD NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters A WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. eral Notes: robes are designed to flash at 1 flash per second minimum over their 'Regulated Voltage Range" (16-33v for 24VDC units and -17.5v for I2VDC units). Regulated Voltage Range is the newest terminology used by UL to identify the listed voltage range. All candela ratings represent minimum effective Multitone Strobe intensity based on UL Standard 1971. MT Strobe models are UL Standard 1971 Listed for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ±2%. The MT-12/24, MTWP and MT4 models and listed for outdoor use at -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95% (See Data Sheet S9004 or Installation Instruction Sheet P84150 for more detail on MTWP). MTWP and MT4 strobes are listed under UL 1638. MT Audible is UL Standard 464- Listed. Alarm Tones TONE ALARM TONES PATTERN DESCRIPTION HORN BROADBAND HORN (Continuous) BELL 1560 Hz MODULATED (0.07 sec. ON/Repeat) MARCH TIME HORN HORN (0.25 sec. ON/0.25 sec. OFF/Repeat CODE-3 HORN HORN (ANSI S3.41 Temporal Pattern) CODE-3 TONE 500 Hz (ANSI S3.41 Temporal Pattern) - SLOW WHOOP 500-1200 Hz SWEEP (4.0 sec. ON/0.5 sec. OFF/Repeat) SIREN 600-1200 Hz SWEEP (1.0 sec. ON/Repeat) HI/LO 1000/800 Hz (0.25 sec. ON/Alternate) Table 1: dBA and Currant Ratings for Multitone Audible Portion RMS Current (amps) dBA @ loft (UL Reverberant) dBA 1 Oft (UL Reverberant) 24 VDC 12 VDC 120 VAC 24 VDC 12 VDC 12 and 24 VDC 120 VAC HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output HI Output STD Output @ 24 VDC- UL max* @ 24 VDC UL max* @ 24 VDC UL max* @ 24 VDC UL max* UL max* UL max* Horn 0.074 0.108 0.033 0.044 0.145 0.176 0.023 0.034 0.050 0.042 92 87 90 77 99 93 88 82 Bell 0.040 0.053 0.018 0.024 0.077 0.095 0.014 0.020 0.041 0.039 86 80 85 69 92 87 82 75 March Time Horn 0.067 0.104 0.033 0.038 0.109 0.142 0.023 0.034 0.050 0.040 89 84 89 74 99 93 85 79 Code3 Horn 0.069 0.091 0.026 0.035 0.100 0.142 0.023 0.034 0.050 0.042 88 83 88 73 99 93 85 75 Code-3 Tone 0.061 0.075 0.026 0.035 0.088 0.105 0.015 0.021 0.042 0.040 85 80 84 70 95 90 79 75 Slow Whoop 0.069 0.098 0.028 0.037 0.100 0.142 0.025 0.035 0.050 0.042 90 89 89 75 99 94 88 82 Siren 0.080 0.104 0.027 0.036 0.122 0.152 0.021 0.030 0.045 0.041 89 84 89 75 98 93 85 82 HI/LO 0.044 0.057 0.020 0.026 0.089 0.114 0.018 0.026 0.042 0.039 86 81 86 71 93 88. .82 79 Table 2: Strobe Current Ratings) RMS Current (amps) Model MT-121575 MT-241575 MTWP-2475 MT-24MCW ela 1575cd 1575cd 180cd 15ôd 30cd I 75cd I llOcd 4VDC 0.152 0.060 0.094 0.041 11 0.063 0.109 0.140 UL max* 0.255 0.090 0.138 0.060 0.092 1 0.165 1 0.220 Note: If the strobe and audible operate on the same circuit, add the strobe current from Table 2 to the audible current from Table 1. * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings see installation instructions. STROBE AUDIBLE Wiring Diagrams (for all models) MT SIGNAL AUDIBLE SIGNAL AND STROBE OPERATE INDEPENDENTLY PRECEDM FROM PRECEDING , ONEXT APPJANCE, ----.44-, r - APPUANCEOR FACP - SMIDEM, I I I LOLa rt1t11 PS-I224P I O O I IN.NVIN. + POWER I I UPPLIES - + PROP ok,,AL OR FAP Specifications and Ordering Information IN UNISON. RED AND BLACK SHUNT-WIRES ARE SUPPLIED. - AILP ECV FROM T N EXT PRECEDING + +RED APPLIANCE APPLIANCEUIRUWCR - - OREOLR S1ROW AUDIBLE S Model Number Order Code Input Voltage Rated Candela Mounting Options * Agency Approvals UL MEA CSFM FM BFP MT-12124-R 5023 12/24 - D,E,F,L,M,O,P,R X X X X X MT-12/24-W 5024 12/24 - D,E,F,L,M,O,P,R X X X X X MT-241575W-FR' 8422 24 15(75onAXIS) D,E,F,L,M,O,P,R X X X X * MT-24MCW-FR 3301 24 15/30/75/110 D,E,F,L,M,O,P,R X * X * * MT-24MCW-FW 3303 24 15/30/75/110 .D,E,F,L,M,O,P,R X * X MT121575WFR# 8421 12 15(75onAXIS) D,E,F,L,M,O,P,R X X X X * MT-121575W-NW 9747 12 15 (75 on AXIS) D,E,F,L,M,O,P,R X X X X * MTWP2475WFR** 8420 24 180 @ 77°F (25°C) M X X X X * MT\NP2475WNW** 9744 24 1 180 @ 77°F (25°C) M X X X X * MT4-115-R 6223 120 VAC - D,E,J,K,N,O,R X X X X X MT4-115-S 6142 120 VAC - D,E,J,K,N,O,R X X X X X MT4-115-WH-VFR## 6224 120 VAC 15 D,E,J,K,N,O,R X X X X X MT4-12/24-R 5308 12/24 - D,E,J,K,N,O,R X * * * * MT4-12/24-S 7997 1 12/24 - D,E,J,K,N,O,R I X * * * * NOTE: °°MTwP-2475w is Weatherproof and rated for 180 cd @77°F (25°C). See Data Sheet S9004 or Installation Instruction P84150. ***For additional information on mounting please refer to Data Sheet S7000. * # 1575 strobes are UL Listed for 15cd with 75cd on AXIS. Pending ## Series WH Strobe is listed for UL Standard 1638 only. See Instruction Sheet P83160. ¼ARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS" P82467 MT-12/24, P84155 MTw/Strobe P84150 MTWP WEATHERPROOF "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS DO UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The notification appliance shall be a Wheelock Series MT audible/visual appliance or equivalent. Notification appliance shall be electronic and use solid state components. Electromechanical alternatives are not approved. Each electronic appliance shall provide eight (8) field selectable alarm tones. The tones shall consist of: HORN, BELL, MARCH TIME HORN, CODE-3 HORN, CODE-3 TONE, SLOW WHOOP, SIREN and HI/LO. Tone selection shall be by durable dip switch assembly and not clips or jumpers. The Ititone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances. The audible and the strobe shall able to operate from a single NAC circuit while producing any of these tones. The appliance shall provide two output sound levels: STANDARD and HIGH dBA. The HIGH dBA setting shall provide a minimum 5 dBA increase in sound output at nominal voltage. The HIGH anechoic dBA measurement at 10 feet at the alarm HORN SETTING shall be 99 dBA minimum. Operating voltages shall be either 12 VDC or 24 VDC using filtered power or unfiltered power supply (full-wave-rectified). All models shall have provisions for standard reverse polarity type supervision and IN/OUT field wiring using terminals that accept #12 to #I8AWG wiring. Combination audible/visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens or equivalent with solid state circuitry. Strobe shall produce a flash rate of one (1) flash per second minimum over the voltage range. The MT strobe intensity shall be rated per UL and Listed-under Standard 1971 for Signaling Devices for the Hearing Impaired for 1575cd multi-candela with field selectable 15/30/75/110 candela settings. The 1575 candela strobe shall be specified when 15 candela or with 75 candela intensity on-axis is required. Strobe Models shall incorporate circuitry for synchronized strobe flash and shall be designed for compatibility with Wheelock SM and/or DSM Sync Modules or Wheelock's Power Supplies with Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the module fails to operate (i.e., contacts remain closed), the strobes shall revert to a non-synchronized default flash rate. Strobe activation shall be via independent input or from the same input circuit as the audible. The combination audible/visual appliances shall be installed indoors and may be surface or flush mounted. They shall mount to standard electrical hardware requiring no additional trimplate or adapter. The aesthetic appearance shall not have any mounting holes or screw heads visible when the installation is completed. The appliance shall be finished in a textured red color. The Series MT-12/24, MTWP and MT4 appliances may be installed indoor or outdoor with the proper back box. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. S tran W1 chport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com M WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S2000 MT 06/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUThDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1076:189 Page 1 of I CATEGORY: Control Unit (Non High-Rise) LISTEE: Kidde-Fenwal, Inc., 400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 FAX (508) 881-1773 DESIGN: Kidde Fire Systems Model AEGIS fire alarm control unit. Automatic, manual, local, central station, protected premises, waterfiow, sprinkler supervisory and releasing device services. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Primary: 120/240 VAC, Standby: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and FM label. SAPPROVAL: Listed as a fire alarm control unit for use with listee's separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation instruction Manual for details. Control unit meets the requirements of the 9 1 Edition of ANSI/UL 864. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 04-18-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION S1 OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1076:187 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Kidde-Fenwal, Inc., 400 Main St., Ashland MA 01721 Contact: Terrill Garland (508) 881-2000 FAX (508) 881-1773 DESIGN: Models PSD-71 57 and PSD-71 57D photoelectric type smoke detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10.2 -36.8 VDC normal, 24 VDC alarm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a photoelectric smoke detector for use with listee's 2-WIRE, 2WRLT, 2WRB, 4WRB or MA-001 bases (CSFM Listing No. 7300-1076:116) and separately listed compatible control units. Model PSD-7157 for open area protection between 0 and 300 fpm and Model PSD- 71 57D for open area protection between 0 and 4000 fpm. Suitable for releasing device service when using Models 2WRB, 4WRB bases, and Mechanical Adapter base Model MA- 001. 12-02-2005 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No: 7300-1076:116 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Kidde-Fenwal Inc., 400 Main St., Ashland MA 01721 Contact: Terrill Garland (508) 881-2000 FAX (508) 881-1773 DESIGN: Models 2-WIRE, 2WRLT, 2WRB, 4WRB, 4SB, 6SB smoke detector bases, Model ASM-6SB (70-200200-002) addressable signal sounder module with base and Models MA-001 and MA- 002 smoke detector adapters. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10.2 - 36.8 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. S APPROVAL: Models 2-WIRE, 2WRLT, 2WRB, 4WRB are listed as smoke detector bases and Model MA- 001 is listed as a smoke detector adapter for use with Models CPD-7051 (CSFM Listing No. 7271-1076:115), PSD-71 55 or PSD-71 56 (CSFM Listing No. 7272-1076:117) smoke detector heads and separately listed compatible fire alarm control units. Models 2WRLT, 2WRB, 4WRB, 4SB and 6SB are also suitable for duct applications when used with Model RCM500 remote test/LED. Models 2WRB and 4WRB are suitable for releasing device service. Models 4SB, 6SB are listed as smoke detector bases and Model MA-002 is listed as a smoke detector adapter for use with listee's separately listed *compatible fire alarm control units. Model ASM-6SB is listed as a smoke detector base with addressable signal sounder module for use with detector Models PSD-7152 (CSFM Listing No. 7272-1076:142), CPD-7052 (CSFM Listing No. 7271-1076:145) and THD-7252 (CSFM Listing No. 7270-1076:143) smoke detector heads and separately listed compatible fire alarm control units. *Rev. 03-21-08 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 W Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0785:118 Page 1 of I CATEGORY: Audible Devices LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Model MT-12/24, MT-115 and MT4-12124, and MT4-115 multi-tone audible devices followed by R, W, 5, or X to indicate package color. Models MT-12, MT4-12, MT-24, MT4-24 multi-tone audible/strobe signals followed by A, B, G, R or W to indicate lens color, followed by S (15 ed), H (15 Cd) or M (117 Cd) to indicate strobe intensity, and other suffixes to designate orientation, lens lettering and plate color. Models MT-1 1 5-WH and MT4-1 15-WH multi-tone audible/visual devices (Rated 15 cd). Refer to listee's data sheet for additional detailed product description and operational. considerations. RATING: Suffix -12: *8175VDC -24: *1633 VDC -115: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes S and ordinances and in a manner acceptable to the authority having jurisdiction. Models MT series are surface mount and suitable for outdoor with Model lOB back box. Models MT4 series are flush mount and suitable for outdoor with model WBB back box. MARKING:, Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed electrically compatible fire alarm control units. Not suitable for the hearing impaired application. These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2008 Listing Expires June 30, 2009 0 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1076:147 Page 1 o I CATEGORY: Boxes/Pull Stations LISTEE: Kidde-Fenwal, Inc., 400 Main Street, Ashland, MA 01721 Contact: Terrill Garland (508) 881-2000 *FA)( (508) 881-1773 DESIGN: Models BIO and Bli, 30-195000-002, 30-195000-004, *30..330001..001 *30..330001..002 *84..330001..001 and *84..330001..002 key lock, push bar, noncoded manual pull stations; Models 30-195000-001 and 30-195000-003 key lock, no push bar, noncoded manual pull stations. Suitable for outdoor use when installed with Model SGB-32C back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. XLF: 7150-1408:107 *Rev. 04-12-2003 This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: S Authorized By: JUNE 4 2008 BEN HO, Chief Fire Engineering Division Listing Expires June 30, 2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1076:120 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Kidde-Fenwal, Inc., 400 Main Street, Ashland MA 01721-2150 Contact: Terrill Garland (508) 881-2000 *FA)( (508) 881-1773 DESIGN: Models PIN 30-232001-001 front panel w/cutout for audible and P/N 30-232001-002 front panel w/o cutout for audible. These units have a manual release switch and abort switch. Models 878752-01/-02, 30-193000-001/-002 abort stations. Models 296105, 30-193000-003 back boxes. Models 30-322003-003, 84-322003-003 Remote Display Unit Backbox. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only. S MARKING: Listee s name, model number, and UL label. APPROVAL: Models 30-232001-001 and 30-232001-002 are listed as control unit accessories when used in conjunction with listees' separately listed fire alarm control units. Models 878752-01/-02, 30-193000-001/-002 abort stations and Models 296105, 30- 193000-003 back boxes are intended for use with listed releasing device control units. *Rev. 06-21-2003 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division 'FSchmidt Fire Protection E l l . , I n c . lei 4760 MURPHY CANYON RD. • SAN DIEGO, CA 92123 • (858) 279-6122 • FAX (858) 279-3583 INSPECTION MORT Job Name: ______________________________________________ Contract #: Job Address: Contractor/Owner Name: Contractor/Owner Address: Insurance Rating Agency: Fire Department: 0 Pre-Action System No. of Systems: Sq. Ft. Smoke Detectors: Heat Detectors: Accepted By: Date: 0 Alarm Rough-In Smoke Detectors: Heat Detectors: Pull Stations: _________________________________ Horn/Strobes: Other: Accepted By: Date: 0 FM-200 System No. of Systems:. Functional Test of Devices: Door Fan Test: Accepted By: Date: 0 Oilier System Type of System: Functional Test of Devices: Door Fan Test: Discharge Test: Accepted By: Date: 4ail&vz • cie of e 4u'W cvoo