Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2200 FARADAY AVE; ; FA120054; Permit
10/28/21, 8:48 AM FA120054 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2200 FARADAY AV Permit Type: FALARM Parcel No: 2121206000 Lot #: 0 Reference No.: PC #: Project Title: LEGEND 3D Permit No: FA120054 Status: ISSUED Applied 11/30/2012 Approved: 11/30/2012 Issued: 11/30/2012 Inspector: Applicant: Owner: NOVA SECURITY D L FARADAY L P SUITE 103 C/O DRA ADVISORS LLC 8779 COTTONWOOD AV 220 E 42ND ST 27TH FLOOR SANTEE, CA NEW YORK NY 619-448-3007 Fees ($) Add'I Fees ($) Total ($) Balance 396 ($) 0 1396j o 1/1 LEGEND 3D SUITE 100 2200 FARADAY AVE. CARLSBAD, CA. 92008 Fire Alarm Submittal 11-28-12 Submitted By; NEVA SECURITY 8779 Cottonwood Ave. Suite 103 Santee, CA. 92071 619-448-3007 Cont. Lie. C-10 # 802053 LEGEND 3D Fire Alarm Submittal Equipment List Description Model Manufacture CSFM# Fire Alarm Panel 5820XL SILENT KNIGHT 7170-0559:136 Fire Alarm Annunciator 5860 SILENT KNIGHT 7170-0559:136 Smoke Detector SD505-APS SILENT KNIGHT 7272-0559:129 Manual Pull Station SDSOO-PS SILENT KNIGHT 7150-0559:136 Addressable Input Module SD500-AIM SILENT KNIGHT 7300-0559:132 Addressable Relay Module SD500-ARM SILENT KNIGHT 7300-0559:132 Strobe Multi-cd clg mnt STC COOPER 7125-0785:168 Strobe Multi-cd wall mnt ST COOPER 7125-0785:168 Horn/Strobe Multi-cd cig mnt HSC COOPER 7125-0785:168 Horn/Strobe Multi-cd wall mnt HS COOPER 7125-0785:168 r 3 SILENT KNIGHT intelliKnight® Model 5820XL, QD Addressable Fire I. by Honeywell Alarm Control System, The lntelliKnight System is the easy way to make the most of fire alarm technology. lntelliKnight 5820XL',is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description '5820XL is an intelligent addressable fire alarm control panel '(FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol Built in support for 127 SD devices, expandable to 508 SD evices using the SD protocol.1 Uses standard wire—no shielded or twisted pair required \Built-in digital communicator' Central station reporting by point or by zone Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® FlexputTM I/O circuits Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Improvements in SKSS software deliver five times faster uploads/downloads Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Model 5820XL 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Programmable date setting for Daylight Saving Time Installation The 5820XL can be surface or flush mounted Compatibility' The 5820XL signal line circuit (SLC). supports multiple device types of the same protocol SK (System Sensor) SD. You cannot mix SD and SK SLC devices on a FACP. lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal System Application 5820XL has one built-in signalling line circuit (SLC) which supports multiple devices dependent on protocol being used. Three additional loops can be added using the 5815XL SLC expanders to increase overall capacity. The 5820XL SLC loops support multiple device types, including: Addressable photoelectric smoke detector Addressable ionization smoke detector Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module Addressable beam detector (SK protocol only) Addressable multi-criteria smoke detector (SK protocol only) Addressable multi modules (SK protocol only) The following advanced sensor capabilities are available with 5820XL: Automatic drift compensation Maintenance alert Built-in sensor test to comply with NFPA 72 calibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours. An additional cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. Flexput circuits on 5820XL control can be individually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4-wire smoke detectors. The 5820XL system operates on non- twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51 specifications for power-limited fire protective signalling cables. No special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the IntelliKnight system features a built-in walk test and auto- programming. Its innovative, dead-front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. Programming The InteIliKnight system offers several options to simplify and speed up programming. The JumpStart® feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windows® based software. Built-In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch-Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel InteIliKnight 5820XL WnrwRed Facility Addressable Fire Alarm System ManagementSoftwae SK (System Sensor) Protocol Devices Wedows Dosed Up/Download Softwo U _ Compatiale CS Receiver tamatica Software Internet SK-2/2UD Connection isorAtarm P Communicator -.-w-ua bIUUC -wIflIm) Sic-Relay-b SR-Zone (day SK-Pull-SA ssatlr MtiIOF R'' ConrI AAI-v;;atla AdLlo Lu Mrcule Mdutr :nerfce Rtw I Pfl Oo lIot, rvae I -I I Uaethe58OWconIroIupto4 I - 5883 Relay Interface Modules lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.5A or 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power-limited - ,Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power-limited Auxiliary power circuits: 3A @ 27.4VDC per circuit, power-limited Initiation Circuits: 100 mA @ 27.4VDC per circuit, power limited Physical Flush Mount Dimensions: 14.5W x 24.75"H x 3.9"D (36.8 W x 62.9 H x 9.8 D cm) Overall Dimensions: 16.2W x 26.4"H x 4.2"D (40.6W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Battery Charging Capacity: 7.0-35 AH Battery Size: 18 AH max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) 'S-BUS Accessories' 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 5860R is red. 581 5XL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the lntelliKnight system. 5820XL supports three 5815XL's. Each 5815XL can support 99 SK detectors and 99 SK modules or 127 SD devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6 Flexput 110 circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides four power-limited notifi- cation appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs, and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W 254 mm H x 152 mm D) 5D505-DTS-K Remote test switch. Used with SD505-DUCTR. Provides remote key operated test function and annunciation of detector alarm. SD and SK Devices See the specification sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices Data Sheet 53623 SK Devices Data Sheet D SILENT This document is not intended to be used for installation purposes. We try to keep our Made in America product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 PN 350210 Rev H2 by Honeywell Phone: (203) 484-7161, Fax: (203) 484-7118. www.sitentknight.com. © 2012 Honeywell International Inc. lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0135 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURlTY7556Mehdian Circle, Maple Grove, MN 553694927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5820, '5820XL lFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820,5820XL IFP-1000: Control Units 058200P: Motherboard 581515815XL: Analog Loop Expander 7628: EOL Resistor Intelliknight 5820: Enclosure '5860/5860R/RA-1 000:(Annunciator 5496: Power Module 5824: Serial/Parallel Interface 5895/5895XURPS-1000: Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SD500-ANM : Addressable Notification Module SD500-LlM : Line Isolation Module 5D505-61B: Isolation Base SD-500 SDM: Smoke Detector Module RA-100 : Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB: Battery Cabinet 5897, 5898: Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineenng staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires 'June 30, 2013's Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Listing No. 7165-0559:0135 Page2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZAor EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division • Listing Expires,\1June 30, 2013 Before You Begin Installing '3.6.1.2 Current Draw Worksheet for SD SLC Devices' Use Table 3-3 to determine current requirements during alarm/battery standby operation when SD SLC devices are installed. You can install up 127 SD devices per loop (508 max per panel). Copy this section if additional space is required. Table 3-3: Current Draw Worksheet for SD SLC Devices Device # of Devices J Current per Device Standby Current Alarm Current For each device use this formula: Thfs column X This column = Current per number of devices. IntelliKnight 5820XL Fire Panel (Current draw from battery) Standby: m 215 A 215 mA Alarm: .385 mA 385 mA Addressable SLC Devices SD5 00-AIM, (508 max.)1 Standby/Alarm: mA mA mA SDSOO-MIM mA mA SDSOO-PS D500ARM. mA mA 5D505-AHS mA mA SD505-AIS mmA. mA ,SD505-APS mA mA SD500ANM (508 max.)' Aux. Pwr Standby: 8 mA mA Mann: 60 mA mA SLC Standby/Alarm: .55 mA mA mA SD500-SDM (508 max.)' SLC Standby/Alarm: .55 mA mA mA Aux. Pwr Standby: 20 mA mA Alarm: 106 mA mA SD500-LED (100 max.)' Aux. Pwr Standby: 10 mA mA Alarm: 220 mA mA LED: 10 mA mA mA SLC Standby/Alarm: 0.55 mA mA mA SLC Accessory Bases SD505-6RB (508 max.) Standby/Alram: 0.082 mA mA mA SD505-6SB (508 max.) Aux. Pwr Standby: 1 m mA Alarm: 32 mA mA SLC Standby/Alarm: .082 mA mA mA 5D505-DUCTR (508 max.) Aux. Pwr Standby: 20 mA Alarm: 62 mA2 mA SLC Standby/Alarm: .5 mA mA I mA SD505-DTS-K (508 max.) None, included with SD505-DUCTR worst case. SD505-DUCT (508 max.) None, included with detector current. SLC Isolator Devices SDSOO-LIM (1024 max.) Standby/Alarm 0.092 mA I I mA5D505-6IB mA I I (508 max.) Accessories Modules 5815XL SLC Expander (3 max.) Standby/Alarm: 55 mA mA mA .5860 Remote Fire Alarm Annun. 8 max.): Standbys, 20'A mA Alarm: '25 mA mA 5824 Serial/Parallel Printer Interface (2 max.) Standby/Alarm: 45 mA mA mA 5895XL IntelliKnight Power Expander (8 max) Standby/Alarm: Ion A mA mA Inte 5496 lligent Power Module Standby/Alarm: 10 mA mA mA 151209 3-11 lntelliknight 5820XL Installation Manual A C D E F G H Device # of Devices Current per Device Standby Alarm Current Current 5865-4 LED Annunciator (with reset and silence switches) (8 max.) Standby: 35 mA mA Alarm: 145 mA mA 5865-3 LED Annunciator Standby: 35 mA mA Alarm: 145 mA mA 5880 LED I/O Module Standby: 35 mA mA Alarm: 200 mA mA 5883 Relay Interface (32 max.) Standby: 0 mA mA Alarm: 220 mA (22 mA per relay) mA Total System Current Auxiliary Devices3 Refer to devices manual for current rating. Alarm/Standby: mA mA mA Alarni/Staiidby: mA mA mA Alarm/Standby: mA mA mA Alarm/Standby: mA mA mA Auxiliary Devices Current Alarm: mA mA Alarm: mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Total current ratings of all devices in system (line A + line B + C) mA mA Total current ratings converted to amperes (line D .001): A A Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): H Multiply lines E and F. Total standby AH AH Alarm sounding period in hours. (For example, 5 minutes .0833 hours) H Multiply lines E and H. Total alarm AH AH Add lines G and 1. 4 Total ampere hours required AH I. Total does not include isolator devices or accessory bases. If using 24 VDC aux power only. No standby or alarm current for battery calculation if using 24 VAC, 120 VAC or 240 VAC. If using door holders, you do not need to consider door holder current for alarm/battery standby, because power is removed dur- ing that time. However, during normal operation, door holders draw current and must be included in the 6.OA total current that can be drawn from the panel. Use next size battery with capacity greater than required. 3-12 151209 Before You Begin Installing 3.6.1.3 Maximum Battery Standby Load Table 3-4 shows the maximum battery standby load for the 5820XL based on 24 and 60 hours of standby. The standby load calculations of line D in the Current Draw Calculation Worksheet (Table 3-2 for SK devices and Table 3-3 for SD devices) must be less than the number shown in Table 3-4 for the battery size used and standby hours required * 33AH max battery size for FM (Factory Mutual) installations. Table 34: Maximum Battery Standby Load Rechargeable Battery Size Max. Load for 24 hrs. Standby, 5 mins. Alarm *Max Load for 60 hrs. Standby, 5 mins. Alarm 7 A 270 m 105 m 12 A 475mA 190 m 18 A 685 m 270rnA 35 A I.3A 540 m * RequiredforNFPA 72AuxiliatyProtectedFireAlarm systems forFireAlarm Service (City Box) andRemote Station Protected Fire Alarm systems (Polarity Reversal) and Digital Alarm Communicator/Transmitter (DACT). Silent Knight does not support the use of batteries smaller than those listed in Table 3-4. If you use a battery too small for the installation, the system could overload the battery resulting in the installation having less than the required 24 hours standby power. Use Table 3-4 to calculate the correct battery amperes/hour rating needed for your installation. 151209 3-13 Addressable Photoelectric Type Smoke Detector Detect smoldering fires quickly and get help fast with lntelliKnight® photoelectric smoke detectors. lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-APS compensates automatically for contamination in the environment. And detector testing is simple—even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. Model SD505-APS Analog I Addressable Photoelectric Type Smoke Detector The SD505-APS is particularly suited to detecting dense smoke typical of fires involving materials such as soft furnishings, plastic, foam or other similar materials which tend to smolder and produce large visible particles. The detector features automatic compensation for contamination and a simple detector calibration test procedure that can be run from the panel or remotely (using the WindowsTM based downloading software). Operation The SD505-APS units made up of an LED light source and a silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event or fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Under normal conditions, the status LED blinks approximately every 15 seconds, indicating that the head is communicating with the loop. The LED lights continuously during the alarm period. Features Low profile, 2 inches, including base Simple and reliable addressing without mechanical switches Automatic compensation for sensor contamination Built-in fire test feature Simple detector calibration testing through the control panel or remotely through a WindowslM based computer software. Vandal-resistance locking features Field cleanable UL listed, meets NFPA 72 Ch 7 requirements CSFM approved MEA approved FM Approved SD505-APS Smoke Detector Specifications Operating Voltage: 1741 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: 4" Square, 4" OCT, Single gang mud ring Relative Humidity: 85% noncondensing Air Velocity: 0 - 300 FPM Compatible Bases: SD505-6AB (Sold Separately) (6" Base) SD505-4AB (4" Base) I SILENT KNIGHT by Honeywell :"Model SD505-APS ______ Addressable Photoelectric Type Smoke Detector 61 Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Diameter = 3-15116' 0 0 Height =2 inches, including base Model SD505-6AB Detector Base Model SD505-APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev C,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2005 Silent Knight Phone: (800) 328-0103, Fax: (763) 493-6475. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL. - - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0129' Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRlc LISTEE: 'SILENT KNIGHTSECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Model SD505-APS'analog addressable photoelectric type smoke detector 'with model SD5054AB and SD505-6AB bases. Unit consists of resistors, capacitors, diodes, transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 39.5 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7272-0410:0149 *Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires',',June-30, 201S Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division 'SD500-AIM' & SD500-MIM A 1 :AddressabIeinput Modules: 1 ______ lntelliknight's addressable contact monitor modules combine fast response with pinpoint I location ID. A combination that saves lives and property. The 5D500-AlM adSD5OO-PvilP!1 arddressable input modules for use with Silent Knight IntelliKrght fire alarm control panels (FACP). The SD500-AIM and SD500-MIM are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister, they monitor for alarm contact closures and for open circuit wiring fault conditions. The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy installation and stable operation—a flexible solution for all your fire protection needs. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description The SD500-AIM and SD500-MIM are addressable input modules for use with the Intelliknight fire alarm control panels (FACPs). The SD500-AIM addressable input module mounts to a 4'-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features Single contact monitor SD500-AIM supports Class A (Style D) or Class B (Style B) contact monitor wiring SD500-MIM support for Class B (Style B) contact monitor wiring Attractive ivory cover plate with the 5D500-AI M Small and lightweight size allows for flexible mounting options with the SD500-MIM DIP switch programmable for fast installation Up to 2500 ft wiring distance from either input module to contact Use up to 14 gauge wire UL listed Electrical Specifications Standby Current: 0.55 mA Alarm Current 23 mA max for one device; 46 mA max for two devices; .55 mA foe each additional device Line Resistance: 500 max Mechanical Specifications SD500-AIM Physical Description Dimensions: 4.9" W x 4.9' H x 1' D (12.4Wx 12.4 Hx2.5Dcm) Weight: 3.6 oz (120.1 g) Color: Ivory cover plate SD500-MIM Physical Description Dimensions: 1.5" W x 2.5' H x 0.7" D (3.8 W x 6.4 H x 1.8 D cm) Weight: 1.6 oz (45.4 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing 60500-AIM r SD500-MIM Approvals NFPA71 &NFPA72 UL 864 CSFM 7300-0559:132 MEA429-92-E Vol. IX FM Approved for use with the 5820XL SILENT 17 KNIGHT by Honeywell EfX N ur Jar=;[N SD500-AIM & SD500-MIM Addressable Input Modules Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight SD500-AlMor SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's (ntelliKnight FACPs. The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The 5D500-AIM addressable input module must provide a monitor LED that is visible from outside the cover plate L-' ---, -: . V.,.. II I IT Compatible FACPs 5820XL 5808 5700 Ordering Information SD500-AIM Input Module Addressable input module with ivory cover plate. SD500-MIM Input Module Addressable mini input module. SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103 or 763-493-6400 Fax: (763) 493-6475. www.silentknight.com MADE IN AMERICA FORM# 350231 Rev D, © 2008 Honeywell International Inc 0 SILENT 'Model SD500-ARM' JKNIGHT 'Addressable Relay Module by Honeywell Place relay applications anywhere on the lntelliKnight loop with the SD500-ARM Addressable Relay Module. The SD500-ARM is an addressable device that adds great flexibility to the lntelliKnight system. Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500-ARM allows you to control a wide variety of normally open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applications can be located at any point in the signaling line circuit. Like other lntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection devices—easy installation and stable operation—and it adds up to a flexible solution for all your fire protection needs. Model SD500-ARM Addressable Relay Module The SD500-ARM provides two Form C contacts rated at 2A @ 30 VDC or .6A @ 120 VAC. These contacts can be used for virtually any normally open or normally closed application. Operation Each relay module is programmed with a unique SLC loop address. When an event that controls the relay module occurs, the relay is triggered by the lntelliKnight panel. Features Two sets of Form C contacts. Contacts are rated at 2A @ 30 VDC or .6A @ 120 VAC. Up to 127 relays can be used on each SLC loop. Relay programming is completely flexible—can be mapped to zone conditions. Polling LED visible through cover plate. Specifications Contact Rating: Form C 2A@30VDC .6A@ 120 VAC Standby Current:, '.55 mA' 'Alarm Current:, .55 m Ambient 32°F to 120°F Temperature (0°c to 49°C) Mounting 4-square electrical box c: f Model SD500-ARM Approvals UL listed, complies with NFPA 72. CSFM approved MEA Approved, 429-92-E, Vol. 9 FM approved Compatible Control Panels 5820XL 5808 5700 'Model SD500-ARM', Addressable Relay Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable relay modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent Knight's lntelliknight FACPs. The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6 amp at 120 VAC. The relay module must be suitable for mounting in a standard 4-square electrical box and must include a plastic cover plate. The relay module board must provide an LED that is visible from the outside of the cover plate. The relay must be fully programmable for such applications as are required by the installation. FRONT VIEW 4-7/8" 1/4" F: 1" Model SD500-ARM Addressable Relay Module Dimensions SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350218 Rev. D subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610. © 2010 Honeywell International Inc. Phone: (800) 328-0103, Fax: (203) 484-7118. www.siIentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. ,7306-0559:0132 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICE LISTEE: 'SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike. mcisaachoneywell.com DESIGN: Model SD500-ARMReIay Module and%D500:AlM SD500-MIM Addressable Input Modules*. Models SD500-ARM provides inputs for a control unit communication circuit and have two sets of dry relay contacts. Models SD500-AIM and -MlM provide additional input circuits*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: SD500-ARM: 120 VAC, 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-11-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 ,Listing Expires, June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division 'SD500-PS and SD500-PSDA Addressable Pull-Station lntelliKnight's'addressable pull stations combine fast response with pin-point location ID. The b5OO-PS andSD500-PSDA are a single action or dual action addressable manual fire alarm pull station for use with Silent Knights lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA provides a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and lasts. Combine all this with the features you've come to expect from Silent Knight - easy installation and stable operation - and it adds up to a flexible solution for all your fire protection needs. 'Model SD500-PS & SD500-PSDA Addressable Pull Station' The SD500-PS is a single action addressable fire pull station, and the SD500--PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction A terminal strip on back of the pull station allows interconnection of the pull station to the SLC of an IntelliKnight control panel. The SD500-PS/PSDA is designed for indoor use in non- explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500- PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features UL Listed CSFM listed ADA compliant Key reset (Same key as Silent Knight enclosures) Surface mount back box available Terminals - accept up to 14 gauge wire Extremely easy to operate Corrosion-resistant gold-plated contacts. Reflective label makes it easier to locate in low light Operation The SD500-PS/PSDA single action pull stations are operated by a pull on the front pull cover of the station. A plunger switch, wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station is reset by returning the front cover to the normal upright position and relocking the station with a reset key. The reset keys are the same keys used on Silent Knight enclosures. The SD500-PS/PSDA includes a status LED which blinks, indicating that the addressable module is communicating with the loop. The status LED lights continuously during an alarm. A dip switch on the addressable module is used to set the unique address. Specifications 'Operating Voltage: 24VbC Standby Current: '.55mA 'Alarm Current' 155mA' OIO AIM All?I .d SD500-PS Ambient Temperature: 32°F to 120°F (0°C to 49°C) Mounting: Single gang box - Optional Red Surface Mount Box PS-SMBB SILENT ___ KNIGHT SD500-PSand SD500-PSDA Addressable Pull-Station Engineering Specifications Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14 gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the key shall match the control panel. Manual station shall contain four terminal blocks with two connected to the addressable module and two connect to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip switch settings Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the American Disabilities Act. FACP LJ II Lt 'v rAc' 5Lr. - Wiring Mir Mounting to Single Mounting to Optional Gang Electrical Box Surface Mount Box SAMS- SD500-PSDA t 4 ElrvVi,.al Duo must be Installing SD500-LK Dimensions SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com MADE IN AMERICA FORM# 350342, Rev. 09/03 Copyright 0 2003 Silent Knight CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0136 Page 1 of 1 CATEGORY: 7150— FIRE ALARM PULL BOXES LISTEE: 'SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike. mcisaac@honeywell.com DESIGN: Model PS-SKSA andSD500-PS fire alarm pull boxes.Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm pull station use with separately listed compatible fire alarm control units. For indoor use only. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. *Updated 08-29-2011 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineenng staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 'Listing Expires June 30, 2013' Authorized By: JASON DEWIIT, Deputy State Fire Marshal Fire Engineering Division (Model 5495' 13 SILENT 'Distributed Power Module 0 - / KNIGHT In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday - what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. aii rA,r uvuuuei 5,495 LU IIU1I-eSStIILIdI high-current Distributed Power Module accessories like magnetic door holders The 5495 is a 6 amp notification power Built-in synchronization for expander that provides its own AC appliances from System power connection, battery charging Sensor®,Gentex®, AMSECO®, circuit, and backup battery for use with Wheelock and Faraday fire and security controls such as the Silent Knight Model 5208 Fire Control Stand alone operation /Communicator. The 5495 is the Cost- Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the Costs Americans with Disabilities Act (ADA). Operates with most polarized, UL The 5495 has built-in ANSI cadence Listed notification devices pattern, which can upgrade older control panels that lack cadence ANSI Cadence pattern output capability. capability built-in Features UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector/indicator Independent trouble relay AC loss delay option shuts off power Connection to Local Fire Control The 5495 may be connected to a local fire Control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VOC. The control panel's notification circuit is connected to one of the inputs on the 5495. The Control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then Connected to the 5495 signal circuits using the 4.7kc end-of-line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. Model 5495 Distributed Power Module Approvals UL Listed MEA429-92-E Vol XII CSFM 7300-0559123' NFPA 72 Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal I Input Signal Circuit Output Signal 2 Input (Optional) 120 VAC Local Fire Control Signal I Distributed Signal 2 Power Module 5495 Signal 3 Signal 4 Aux. Power Trouble Output (Alternative to notification circuit trouble.) Supervision Current: Input The 5495 supervises a variety of 'Standby' 75 mA voltage range: 9 - 32 VDC functions including: Alarm, 205 mA' Battery charging', Low AC power Auxiliary apacity, 35.0 AH Low battery condition power circuit: 1 Ambient temp.: 320 to 1200 F Earth ground fault Notification (0° to 490 C) Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) X 40.64 cm H x output (1 Class A& 7.62 0 cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on: Green condition on the host control signal circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC Aux trouble: Yellow addition, the 5495 provides a Form @ 3.0 amps each, C trouble relay output as an 4.7 kQ EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification No. of inputs 2 AC input: 120 VAC at 2 amps Output: 24 VDC at 6 amps Input configuration: 2 Class B or 2 Class A r' SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all IJ KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev 0 subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-7161 Phone: (800) 328-0103, © 2010 Honeywell International Inc. Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION imp 01 "ria-i"I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0123' Page 1 of 1 CATEGORY: 7300-- FIREALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: 'SILENT KNIGHT 5ECUR1TY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike. mcisaachoneyweII.com DESIGN: Models 5395, 5495 'and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two 12VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: *Rec 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 f \ I Listing Expires June 30, 2013: Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Notification Multiple Voltages 3 Audible Settings 90, 95, 99 dB £i 4 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15130160/75/95/1151150/177 Universal Mounting Base U Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw Strobe, Horn Strobe, and Horn Notification Appliances, Description: The Wheel ock5 ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock5 ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock5 ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation** Sleek Modern Aesthetics Finger Slide Switches Voltage Test Points Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock' Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the 'Regulated Voltage" range 'Compared to competitive models " Patented "Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Genera' Notes: Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range. All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Horn Strobe Ratings'per UL 1971 & Anechoic at 24 VDC UL Max Current-' Anechoic dBA at 99 24VDC 12 VDC Model Regutated Voltage 15J 15/75 3& 60 75 °95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 (1082' b.i02 0.141 :0.148' O.i76 ••••E 0.197 0.242'; :0.282' • 0.125 ••• ______ 7VDC 7Model 24VDC 12VDC Regulate Rang 15 15/75 30 60 75 95 110 115 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 135 150L 0.272 0.230 0.272 0.122 0.153 F/SC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.122 UL Max Current* at Anechoic 90 dBA 24VDC 12VDC Model Regulated Voltage RangeVDC 15 15/75 30 60 75 95 110 115 135 150 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 F0.267 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.120 HornRatings per UL Anechoic Model Regulated Voltage Range VDC 99dB 95dB 90dB F/N 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL may current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Notification Wheelock° (JWDC) SAFEPATW WAV Architects and Engineers Specifications The notification appliances shall be Wheelock' Exceder" Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" 0. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6/11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING lMPAIREb LISTEE: Cooper Wheelock lnc7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe'and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineenng staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 4Jsting Expires. (June 30, 2013' Authorized By: JASON DEWI1T, Deputy State Fire Marshal Fire Engineering Division