HomeMy WebLinkAbout2200 FARADAY AVE; ; FA120054; Permit10/28/21, 8:48 AM FA120054 Permit Data
City of Carlsbad
Fire Alarm Permit
Job Address: 2200 FARADAY AV
Permit Type: FALARM
Parcel No: 2121206000
Lot #: 0
Reference No.:
PC #:
Project Title: LEGEND 3D
Permit No: FA120054
Status: ISSUED
Applied 11/30/2012
Approved: 11/30/2012
Issued: 11/30/2012
Inspector:
Applicant: Owner:
NOVA SECURITY D L FARADAY L P
SUITE 103 C/O DRA ADVISORS LLC
8779 COTTONWOOD AV 220 E 42ND ST 27TH FLOOR
SANTEE, CA NEW YORK NY
619-448-3007
Fees ($) Add'I Fees ($) Total ($) Balance
396
($)
0 1396j o
1/1
LEGEND 3D
SUITE 100
2200 FARADAY AVE. CARLSBAD, CA. 92008
Fire Alarm Submittal
11-28-12
Submitted By;
NEVA
SECURITY
8779 Cottonwood Ave. Suite 103
Santee, CA. 92071
619-448-3007
Cont. Lie. C-10 # 802053
LEGEND 3D
Fire Alarm Submittal
Equipment List
Description Model Manufacture CSFM#
Fire Alarm Panel 5820XL SILENT KNIGHT 7170-0559:136
Fire Alarm Annunciator 5860 SILENT KNIGHT 7170-0559:136
Smoke Detector SD505-APS SILENT KNIGHT 7272-0559:129
Manual Pull Station SDSOO-PS SILENT KNIGHT 7150-0559:136
Addressable Input Module SD500-AIM SILENT KNIGHT 7300-0559:132
Addressable Relay Module SD500-ARM SILENT KNIGHT 7300-0559:132
Strobe Multi-cd clg mnt STC COOPER 7125-0785:168
Strobe Multi-cd wall mnt ST COOPER 7125-0785:168
Horn/Strobe Multi-cd cig mnt HSC COOPER 7125-0785:168
Horn/Strobe Multi-cd wall mnt HS COOPER 7125-0785:168
r
3
SILENT
KNIGHT intelliKnight® Model 5820XL,
QD
Addressable Fire
I.
by Honeywell Alarm Control System,
The lntelliKnight System is the easy way
to make the most of fire alarm technology.
lntelliKnight 5820XL',is the first fire alarm system to provide you with revolutionary value and performance in
addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed
intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift
compensation and maintenance alert are delivered in this powerful FACP from Silent Knight.
For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103.
Description
'5820XL is an intelligent addressable fire alarm control panel
'(FACP). The basic 5820XL system can be expanded by adding
modules such as 5860 remote annunciator, 5815XL signalling
line circuit expander, 5824 serial/parallel printer interface
module (for printing system reports), and 5895XL intelligent
power module. 5820XL supports SD or SK devices. 5820XL
also features a powerful built-in dual line fire communicator that
allows for reporting of all system activity to a remote monitoring
location.
Features
Built in support for 99 SK detectors and 99 SK modules,
expandable to 396 SK detectors and 396 SK modules using
System Sensor protocol
Built in support for 127 SD devices, expandable to 508 SD
evices using the SD protocol.1
Uses standard wire—no shielded or twisted pair required
\Built-in digital communicator'
Central station reporting by point or by zone
Built-in synchronization for appliances from AMSECO®,
Gentex®, Faraday, System Sensor, and Wheelock®
FlexputTM I/O circuits
Supports Class B (Style 4) and Class A (Style 6) configuration
for SLC, SBUS, and Flexput circuits
13 pre-programmed output cadences (including ANSI-3.41)
and 4 programmable outputs
Built-in annunciator with 80-character LCD display
RS-485 bus provides communication to system accessories
Built-in RS-232 and USB interface for programming via PC
Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC
Improvements in SKSS software deliver five times faster
uploads/downloads
Two built-in Form C programmable relays rated at 2.5 amps
at 27.4 VDC
Plex-1 door option combines a dead front cabinet door with a
clear window, limiting access to the panel while providing
single button operation of the reset and silence functions
Model 5820XL
6 amp power supply and maximum
charging capacity of 35 amp hours (An
additional cabinet enclosure is required for
batteries in excess of 18 amp hours)
Programmable date setting for Daylight
Saving Time
Installation
The 5820XL can be surface or flush
mounted
Compatibility'
The 5820XL signal line circuit (SLC).
supports multiple device types of the same
protocol
SK (System Sensor)
SD.
You cannot mix SD and SK SLC devices on
a FACP.
lntelliKnight Model 5820XL
Addressable Fire Alarm Control Panel
Indicator Lights
General Alarm (Red): Flashes when in
alarm; solid when alarm silenced
Supervisory (Yellow): Flashes when a
supervisory condition exists; solid when
supervisory silenced
System Troubles (Yellow): Flashes
when a trouble condition exists; solid
when trouble silenced
System Silenced (Yellow): On when an
alarm, trouble or supervisory condition
has been silenced but not yet cleared
System Power (Green): Flashes for AC
failure; solid when power systems are
normal
System Application
5820XL has one built-in signalling line
circuit (SLC) which supports multiple
devices dependent on protocol being
used. Three additional loops can be
added using the 5815XL SLC
expanders to increase overall capacity.
The 5820XL SLC loops support
multiple device types, including:
Addressable photoelectric smoke
detector
Addressable ionization smoke
detector
Addressable heat sensor
Addressable duct smoke detector
Contact module
Relay output module
Addressable notification module
Addressable beam detector (SK
protocol only)
Addressable multi-criteria smoke
detector (SK protocol only)
Addressable multi modules (SK
protocol only)
The following advanced sensor
capabilities are available with 5820XL:
Automatic drift compensation
Maintenance alert
Built-in sensor test to comply with
NFPA 72 calibration testing
requirements
5820XL features a 6 amp power supply
and maximum battery charging
capacity of 35 amp hours. An additional
cabinet enclosure (PN RBB) is required
for batteries in excess of 18 amp hours.
Flexput circuits on 5820XL control can
be individually programmed to function
as notification circuits, auxiliary power
outputs, or initiation circuits that
support both 2- and 4-wire smoke
detectors.
The 5820XL system operates on non-
twisted, unshielded cable when wired
in compliance with standard wiring
practices as called out in the National
Electric Code 760-51 specifications for
power-limited fire protective signalling
cables. No special wiring is required.
5820XL provides 13 preset notification
cadence patterns (including ANSI 3.41)
and four user programmable selections
for fire alarm notification.
Two programmable general purpose
Form C relay outputs are provided on
5820XL.
Additionally, the IntelliKnight system
features a built-in walk test and auto-
programming. Its innovative, dead-front
cabinet design allows for flush or
surface mounting. System maintenance
is easy to perform.
User Interface
The 5820XL built-in annunciator with
80 character LCD display and large
easy-to-use tactile touchpad can be
used for system operation,
programming and maintenance. It has
five LEDs for alarm, supervisory,
system trouble, system silenced and
system power. System operations
include silencing alarms and troubles,
resetting alarms and the display of
alarm troubles and memory. The
system's non-volatile event history
buffer stores 1000 events for viewing
from the built-in or remote annunciator.
System operation can be initiated with
a mechanical firefighter's key or a valid
4- to 7-digit operator's code.
Programming
The InteIliKnight system offers several
options to simplify and speed up
programming. The JumpStart® feature
minimizes programming
required to start a new system. The
built-in keypad and 5860 remote
annunciator give on-site access to all
programming. You can also program
remotely using the 5660 Silent Knight
Software Suite, which is Windows®
based software.
Built-In Digital Communicator
5820XL features a built-in UL listed
digital communicator for remote
reporting of system activity and system
programming. The communicator has
the ability to seize two telephone lines
to report alarms and troubles to a
monitoring facility. The communicator
supervises two phone lines and will
activate a trouble signal if a line failure
is sustained for more than 45 seconds.
Other communication features include:
retry if communication fails, two phone
number capability, download phone
number capability and Touch-Tone or
rotary dialing. The communicator is
compatible with SIA and Ademco
Contact ID. The format is selectable by
account number.
Approvals
NFPA 13, NFPA 15, NFPA 16,
NFPA 72: Central Station; Remote
Signalling; Local Protective Signalling
Systems; Auxiliary Protected Premises
Unit; & Water Deluge Releasing
Service. Suitable for automatic,
manual, waterfiow, sprinkler
supervisory (DACT non-coded)
signalling services.
Other Approvals: UL Listed;
CSFM 7170-0559: 135;
MEA 429-92-E Vol. VI; FM Approved
lntelliKnight Model 5820XL
Addressable Fire Alarm Control Panel
InteIliKnight 5820XL
WnrwRed
Facility Addressable Fire Alarm System
ManagementSoftwae SK (System Sensor) Protocol Devices
Wedows Dosed
Up/Download
Softwo
U _ Compatiale CS
Receiver
tamatica
Software
Internet
SK-2/2UD Connection isorAtarm
P Communicator
-.-w-ua bIUUC -wIflIm) Sic-Relay-b SR-Zone (day SK-Pull-SA ssatlr MtiIOF R'' ConrI AAI-v;;atla AdLlo Lu Mrcule Mdutr :nerfce Rtw I Pfl Oo lIot, rvae I
-I
I Uaethe58OWconIroIupto4 I -
5883 Relay Interface Modules
lntelliKnight Model 5820XL
Addressable Fire Alarm Control Panel
Specifications
Electrical
Primary AC:
120 VRMS at 50/60 Hz, 2.5A or
240 VRMS at 50/60 Hz, 1.4A
Total Accessory Load: 6A @ 27.4 VDC,
power-limited
- ,Standby Current: 215 mA
Alarm Current: 385 mA
Flexput Circuits:
Six programmable circuits which can be
programmed individually as:
Notification circuits: 3A @ 27.4 VDC
per circuit, power-limited
Auxiliary power circuits: 3A @ 27.4VDC
per circuit, power-limited
Initiation Circuits: 100 mA @ 27.4VDC
per circuit, power limited
Physical
Flush Mount Dimensions:
14.5W x 24.75"H x 3.9"D
(36.8 W x 62.9 H x 9.8 D cm)
Overall Dimensions:
16.2W x 26.4"H x 4.2"D
(40.6W x 67 H x 11.8 D cm)
Weight: 28 lbs. (12.8 kg)
Color: Red
Battery Charging Capacity: 7.0-35 AH
Battery Size: 18 AH max allowed in
control panel cabinet. Larger capacity
batteries can be housed in RBB
accessory cabinet.
Telephone Requirements:
FCC Part 15 and Part 68 approved
Type of Jack: RJ31X (two required)
'S-BUS Accessories'
5860/R Remote Fire Annunciator
Features the same 80 character backlit
LCD display keypad and firefighter's
keyswitch as the 5820XL. 5860 is gray
and 5860R is red.
581 5XL Signal Line Circuit Expander
The SLC expander is used to add more
addressable devices to the lntelliKnight
system. 5820XL supports three
5815XL's. Each 5815XL can support 99
SK detectors and 99 SK modules or
127 SD devices.
5895XL Intelligent Power Module
Adds 6 amps of power, 6 Flexput 110
circuits and 2 Form C relay circuits to a
5820XL system.
5496 Intelligent Power Module
A 6 amp notification power expander
that provides four power-limited notifi-
cation appliance circuit outputs.
5880 LED/10 Module
Features 40 LED outputs, 8 normally
open dry contact inputs, and one piezo
output.
5865-3 and 5865-4
Remote LED Annunciator
Features 30 programmable LED (15
red and 15 yellow) outputs, and a piezo
sounder. The 5865-4 adds a silence
and reset switch to the package.
5883 Relay Board
Features 10 general purpose Form C
relays. Used with 5880 module.
5824 Serial/Parallel Printer
Interface Module
Provides one parallel and one RS-232
serial port for connecting a printer to
the 5820XL. Use to print a real-time log
of system events, detector status
reports, and event history. Interfaces
with building control system.
Miscellaneous Accessories
5660 Silent Knight Software Suite
(SKSS)
User-friendly Windows software for
remote programming of 5820XLs using
a PC. Upload and view panel account
information, event history, and detector
status.
5670 Silent Knight Software Suite
(SKSS)
Powerful end-user facility management
software allows viewing of detector
status and event history via modem or
direct connection.
Plex-1
Dead front cabinet door with clear
window to limit access to the FACP.
RBB
Remote battery box accessory cabinet.
Use if backup batteries are too large to
fit into FACP cabinet. Dimensions:
16" W x 10" H x 6" D
(406 mm W 254 mm H x 152 mm D)
5D505-DTS-K
Remote test switch. Used with
SD505-DUCTR. Provides remote key
operated test function and annunciation
of detector alarm.
SD and SK Devices
See the specification sheets listed
below for a complete listing of the SD and SK devices.
53624 SD Devices Data Sheet
53623 SK Devices Data Sheet
D SILENT This document is not intended to be used for installation purposes. We try to keep our Made in America product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice.
For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 PN 350210 Rev H2
by Honeywell Phone: (203) 484-7161, Fax: (203) 484-7118. www.sitentknight.com. © 2012 Honeywell International Inc.
lntelliKnight & JumpStart are Registered Trademarks of Silent Knight
Flexput is a Trademark of Silent Knight
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7165-0559:0135 Page 1 of 2
CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)
LISTEE: SILENT KNIGHT SECURlTY7556Mehdian Circle, Maple Grove, MN 553694927
Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464
Email: mike.mcisaac@honeywell.com
DESIGN: Models 5820, '5820XL lFP-1000 Fire Alarm Control Units. Power limited, automatic, manual,
local, remote station, central station, waterfiow, water releasing and sprinkler supervisory
service. Refer to listee's data sheet for additional detailed product description and operational
considerations. System components:
5820,5820XL IFP-1000: Control Units
058200P: Motherboard
581515815XL: Analog Loop Expander
7628: EOL Resistor
Intelliknight 5820: Enclosure
'5860/5860R/RA-1 000:(Annunciator
5496: Power Module
5824: Serial/Parallel Interface
5895/5895XURPS-1000: Power Expander/Supply
5865-3/5965-4: LED Annunciator
5880: LED 10 Module
5883: Relay Interface Board
SD500-ANM : Addressable Notification Module
SD500-LlM : Line Isolation Module
5D505-61B: Isolation Base
SD-500 SDM: Smoke Detector Module
RA-100 : Remote Annunciator
3158: Reverse Polarity Module
5220: Direct Connect Module
122365: Enclosure
*RBB: Battery Cabinet
5897, 5898: Power Supplies
058601 : User Interface
RATING: 120 VAC Primary, 24 VDC Secondary
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number, electrical rating, and UL label.
Rev. 04-26-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineenng staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2012 Listing Expires 'June 30, 2013's
Authorized By: JASON DEWITT, Deputy State Fire Marshal
Fire Engineering Division
Listing No. 7165-0559:0135
Page2 of 2
APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating
devices. Also suitable for high-rise applications when used in conjunction with Model
SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio
Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or
EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZAor EVX-4Z Zone Splitters (CSFM
Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing
No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and
functionally compatible initiating and indicating devices. Refer to listee's Installation
Instruction Manual for details.
These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm
Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition.
This control unit meets the requirements of UL-864, 9th Edition Standards.
NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum
Retard/Reset/Restart period shall not exceed 30 seconds.
Fomerly 7170-0559:0135
Rev. 04-26-11 bh
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2012
Authorized By: JASON DEWITT, Deputy State Fire Marshal
Fire Engineering Division
• Listing Expires,\1June 30, 2013
Before You Begin Installing
'3.6.1.2 Current Draw Worksheet for SD SLC Devices'
Use Table 3-3 to determine current requirements during alarm/battery standby operation when
SD SLC devices are installed. You can install up 127 SD devices per loop (508 max per
panel). Copy this section if additional space is required.
Table 3-3: Current Draw Worksheet for SD SLC Devices
Device # of Devices
J
Current per Device Standby
Current
Alarm
Current
For each device use this formula: Thfs column X This column = Current per number of devices.
IntelliKnight 5820XL Fire Panel
(Current draw from battery)
Standby: m 215 A 215 mA
Alarm: .385 mA 385 mA
Addressable SLC Devices
SD5 00-AIM,
(508 max.)1 Standby/Alarm: mA
mA mA
SDSOO-MIM mA mA
SDSOO-PS
D500ARM. mA mA
5D505-AHS mA mA
SD505-AIS mmA. mA
,SD505-APS mA mA
SD500ANM (508 max.)' Aux. Pwr Standby: 8 mA mA
Mann: 60 mA mA
SLC Standby/Alarm: .55 mA mA mA
SD500-SDM (508 max.)'
SLC Standby/Alarm: .55 mA mA mA
Aux. Pwr Standby: 20 mA mA
Alarm: 106 mA mA
SD500-LED (100 max.)'
Aux. Pwr
Standby: 10 mA mA
Alarm: 220 mA mA
LED: 10 mA mA mA
SLC Standby/Alarm: 0.55 mA mA mA
SLC Accessory Bases
SD505-6RB (508 max.) Standby/Alram: 0.082 mA mA mA
SD505-6SB (508 max.) Aux. Pwr Standby: 1 m mA
Alarm: 32 mA mA
SLC Standby/Alarm: .082 mA mA mA
5D505-DUCTR (508 max.) Aux. Pwr Standby: 20 mA
Alarm: 62 mA2 mA
SLC Standby/Alarm: .5 mA mA I mA
SD505-DTS-K (508 max.) None, included with SD505-DUCTR worst case.
SD505-DUCT (508 max.) None, included with detector current.
SLC Isolator Devices
SDSOO-LIM (1024 max.) Standby/Alarm 0.092 mA I
I mA5D505-6IB mA I
I (508 max.)
Accessories Modules
5815XL SLC Expander (3 max.) Standby/Alarm: 55 mA mA mA
.5860 Remote Fire Alarm Annun. 8 max.):
Standbys, 20'A mA
Alarm: '25 mA mA
5824 Serial/Parallel Printer Interface (2 max.) Standby/Alarm: 45 mA mA mA
5895XL IntelliKnight Power Expander (8 max) Standby/Alarm: Ion A mA mA
Inte 5496 lligent Power Module Standby/Alarm: 10 mA mA mA
151209 3-11
lntelliknight 5820XL Installation Manual
A
C
D
E
F
G
H
Device # of Devices Current per Device Standby Alarm
Current Current
5865-4 LED Annunciator
(with reset and silence switches)
(8 max.)
Standby: 35 mA mA
Alarm: 145 mA mA
5865-3 LED Annunciator Standby: 35 mA mA Alarm: 145 mA mA
5880 LED I/O Module Standby: 35 mA mA
Alarm: 200 mA mA
5883 Relay Interface (32 max.)
Standby: 0 mA mA
Alarm: 220 mA
(22 mA per relay)
mA
Total System Current
Auxiliary Devices3 Refer to devices manual for current rating.
Alarm/Standby: mA mA mA
Alarni/Staiidby: mA mA mA
Alarm/Standby: mA mA mA
Alarm/Standby: mA mA mA
Auxiliary Devices Current
Alarm: mA mA
Alarm: mA mA
Alarm: mA mA
Alarm: mA mA
Notification Appliances Current mA
Total current ratings of all devices in system (line A + line B + C) mA mA
Total current ratings converted to amperes (line D .001): A A
Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): H
Multiply lines E and F. Total standby AH AH
Alarm sounding period in hours. (For example, 5 minutes .0833 hours) H
Multiply lines E and H. Total alarm AH AH
Add lines G and 1. 4 Total ampere hours
required
AH
I. Total does not include isolator devices or accessory bases.
If using 24 VDC aux power only. No standby or alarm current for battery calculation if using 24 VAC, 120 VAC or 240 VAC.
If using door holders, you do not need to consider door holder current for alarm/battery standby, because power is removed dur-
ing that time. However, during normal operation, door holders draw current and must be included in the 6.OA total current that
can be drawn from the panel.
Use next size battery with capacity greater than required.
3-12 151209
Before You Begin Installing
3.6.1.3 Maximum Battery Standby Load
Table 3-4 shows the maximum battery standby load for the 5820XL based on 24 and 60 hours
of standby. The standby load calculations of line D in the Current Draw Calculation
Worksheet (Table 3-2 for SK devices and Table 3-3 for SD devices) must be less than the
number shown in Table 3-4 for the battery size used and standby hours required
* 33AH max battery size for FM (Factory Mutual) installations.
Table 34: Maximum Battery Standby Load
Rechargeable Battery Size Max. Load for 24 hrs.
Standby, 5 mins. Alarm
*Max Load for 60 hrs.
Standby, 5 mins. Alarm
7 A 270 m 105 m
12 A 475mA 190 m
18 A 685 m 270rnA
35 A I.3A 540 m
* RequiredforNFPA 72AuxiliatyProtectedFireAlarm systems forFireAlarm Service (City Box) andRemote
Station Protected Fire Alarm systems (Polarity Reversal) and Digital Alarm Communicator/Transmitter
(DACT).
Silent Knight does not support the use of batteries smaller than those listed in Table 3-4. If you use a battery
too small for the installation, the system could overload the battery resulting in the installation having less than
the required 24 hours standby power. Use Table 3-4 to calculate the correct battery amperes/hour rating needed
for your installation.
151209 3-13
Addressable
Photoelectric Type
Smoke Detector
Detect smoldering fires quickly and get
help fast with lntelliKnight® photoelectric
smoke detectors.
lntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where
smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS
photoelectric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds
are wasted in determining location of an alarm.
The SD505-APS compensates automatically for contamination in the environment. And detector testing is
simple—even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for
pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model
SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've
come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection,
and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs.
Model SD505-APS
Analog I Addressable
Photoelectric Type
Smoke Detector
The SD505-APS is particularly
suited to detecting dense smoke
typical of fires involving materials
such as soft furnishings, plastic,
foam or other similar materials
which tend to smolder and produce
large visible particles.
The detector features automatic
compensation for contamination
and a simple detector calibration
test procedure that can be run from
the panel or remotely (using the
WindowsTM based downloading
software).
Operation
The SD505-APS units made up of
an LED light source and a silicon
photo diode receiving element. In a
normal standby condition, the
receiving element receives no light
from the pulsing light source. In the
event or fire, smoke enters the
detector and light is reflected from
the smoke particles to the receiving
element.
The light received is converted into
an electronic signal. Under normal
conditions, the status LED blinks
approximately every 15 seconds,
indicating that the head is
communicating with the loop. The
LED lights continuously during the
alarm period.
Features
Low profile, 2 inches, including
base
Simple and reliable addressing
without mechanical switches
Automatic compensation for
sensor contamination
Built-in fire test feature
Simple detector calibration
testing through the control panel
or remotely through a
WindowslM based computer
software.
Vandal-resistance locking
features
Field cleanable
UL listed, meets NFPA 72 Ch 7
requirements
CSFM approved
MEA approved
FM Approved
SD505-APS Smoke Detector
Specifications
Operating Voltage: 1741 VDC
Current Consumption:
Standby: .55 mA
Alarm: .55 mA
Ambient Temperature: 32°F to 120°F
(0°C to 49°C)
Mounting: 4" Square, 4"
OCT, Single
gang mud ring
Relative Humidity: 85%
noncondensing
Air Velocity: 0 - 300 FPM
Compatible Bases: SD505-6AB
(Sold Separately) (6" Base)
SD505-4AB
(4" Base)
I SILENT
KNIGHT
by Honeywell
:"Model SD505-APS
______ Addressable Photoelectric Type
Smoke Detector 61
Engineering Specifications
The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector
Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be UL® listed compatible
with Silent Knight's IntelliKnight fire control panels.
The base shall permit direct interchange with Silent Knight SD505-AIS Ionization Smoke Detector, or SD505-
AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB.
The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the
flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch.
The calibration of the detector shall be capable of being selected and measured by the control panel without the
need for external test apparatus.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The
locking feature shall be field selectable as required.
The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate
effects of products of combustion in the chamber to ensure testing of detector circuits.
Diameter = 3-15116'
0 0 Height =2 inches,
including base
Model SD505-6AB Detector Base Model SD505-APS Detector Head
(front view) (front view)
SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA
KNIGHT keep our product information up-to-date and accurate. We cannot cover all
specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev C,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Copyright © 2005 Silent Knight
Phone: (800) 328-0103, Fax: (763) 493-6475.
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL. - -
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7272-0559:0129' Page 1 of 1
CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRlc
LISTEE: 'SILENT KNIGHTSECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927
Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464
Email: mike.mcisaac@honeywell.com
DESIGN: Model SD505-APS'analog addressable photoelectric type smoke detector 'with model
SD5054AB and SD505-6AB bases. Unit consists of resistors, capacitors, diodes,
transistors, LED, photo diode, mounted on a printed wiring board inside an enclosure. Refer
to listee's data sheet for additional detailed product description and operational
considerations.
RATING: 39.5 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model designation, electrical rating and UL label.
APPROVAL: Listed as photoelectric smoke detector for use with listee's separately listed compatible fire
alarm control units. Refer to listee's Installation Instruction Manual for details.
XLF: 7272-0410:0149
*Rev. 06-13-06
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2012 Listing Expires',',June-30, 201S
Authorized By: JASON DEWITT, Deputy State Fire Marshal
Fire Engineering Division
'SD500-AIM' & SD500-MIM A
1 :AddressabIeinput Modules:
1
______ lntelliknight's addressable contact monitor
modules combine fast response with pinpoint
I location ID. A combination that saves lives and
property.
The 5D500-AlM adSD5OO-PvilP!1 arddressable input modules for use
with Silent Knight IntelliKrght fire alarm control panels (FACP). The
SD500-AIM and SD500-MIM are designed to be used with pull stations,
water flow switches, and other applications requiring dry contact alarm initiation devices.
The SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits
inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister,
they monitor for alarm contact closures and for open circuit wiring fault conditions.
The SD500-AIM and SD500-MIM offer a compact design for adaptability and pleasing aesthetics as well as easy
installation and stable operation—a flexible solution for all your fire protection needs.
For more information about the lntelliKnight system, or to locate your nearest source, please call
1-800-446-6444, or in Minnesota, call 763-493-6435.
Description
The SD500-AIM and SD500-MIM are
addressable input modules for use with
the Intelliknight fire alarm control
panels (FACPs). The SD500-AIM
addressable input module mounts to a
4'-square box. The SD500-MIM mini
input module fits inside a single gang
box. Both input modules are designed
to be used with pull stations, water flow
switches, and other applications
requiring dry contact alarm initiation
devices.
These modules are supervised, single
input contact monitors. Using an EOL
resistor, they monitor for alarm contact
closures and for open circuit wiring
fault conditions. If a fault occurs in the
wiring, the module alerts the FACP.
Each addressable input module is
programmed with a unique signal line
circuit (SLC) loop address.
Features
Single contact monitor
SD500-AIM supports Class A (Style
D) or Class B (Style B) contact
monitor wiring
SD500-MIM support for Class B
(Style B) contact monitor wiring
Attractive ivory cover plate with the
5D500-AI M
Small and lightweight size allows for flexible mounting options with the
SD500-MIM
DIP switch programmable for fast
installation
Up to 2500 ft wiring distance from
either input module to contact
Use up to 14 gauge wire
UL listed
Electrical Specifications
Standby Current: 0.55 mA
Alarm Current 23 mA max for one
device; 46 mA max for two devices;
.55 mA foe each additional device
Line Resistance: 500 max
Mechanical Specifications
SD500-AIM Physical Description
Dimensions:
4.9" W x 4.9' H x 1' D
(12.4Wx 12.4 Hx2.5Dcm)
Weight: 3.6 oz (120.1 g)
Color: Ivory cover plate
SD500-MIM Physical Description
Dimensions:
1.5" W x 2.5' H x 0.7" D
(3.8 W x 6.4 H x 1.8 D cm)
Weight: 1.6 oz (45.4 g)
Environmental
Operating Temperature:
32°F - 120°F (0°C - 49°C)
Humidity:
10% - 93% non-condensing
60500-AIM
r
SD500-MIM
Approvals
NFPA71 &NFPA72
UL 864
CSFM 7300-0559:132
MEA429-92-E Vol. IX
FM Approved for use with the 5820XL
SILENT
17
KNIGHT
by Honeywell
EfX
N ur
Jar=;[N
SD500-AIM & SD500-MIM
Addressable Input Modules
Engineering Specifications
The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight
SD500-AlMor SD500-MIM. The modules shall be UL listed and compatible with Silent Knight's (ntelliKnight
FACPs.
The SD500-MIM shall fit inside a single gang electrical box. The SD500-AIM shall be supplied with a plastic
cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The 5D500-AIM
addressable input module must provide a monitor LED that is visible from outside the cover plate
L-'
---,
-: . V.,..
II
I IT
Compatible FACPs
5820XL
5808
5700
Ordering Information
SD500-AIM Input Module
Addressable input module with ivory
cover plate.
SD500-MIM Input Module
Addressable mini input module.
SILENT This document is not intended to be used for installation purposes. We try to
KNIGHT keep our product information up-to-date and accurate. We cannot cover all
specific applications or anticipate all requirements. All specifications are
subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian circle Suite 100, Maple Grove, Mn 55369-4927.
Phone: (800) 328-0103 or 763-493-6400 Fax: (763) 493-6475.
www.silentknight.com
MADE IN AMERICA
FORM# 350231 Rev D,
© 2008 Honeywell International Inc
0 SILENT 'Model SD500-ARM' JKNIGHT 'Addressable Relay Module
by Honeywell
Place relay applications anywhere on the
lntelliKnight loop with the SD500-ARM
Addressable Relay Module.
The SD500-ARM is an addressable device that adds great flexibility to the lntelliKnight system.
Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500-ARM
allows you to control a wide variety of normally open and normally closed applications, including
elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is
addressable, these applications can be located at any point in the signaling line circuit.
Like other lntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing
aesthetics. Combine this with the features you've come to expect from Silent Knight fire protection
devices—easy installation and stable operation—and it adds up to a flexible solution for all your fire
protection needs.
Model SD500-ARM
Addressable Relay
Module
The SD500-ARM provides two
Form C contacts rated at 2A @ 30
VDC or .6A @ 120 VAC. These
contacts can be used for virtually
any normally open or normally
closed application.
Operation
Each relay module is programmed
with a unique SLC loop address.
When an event that controls the
relay module occurs, the relay is
triggered by the lntelliKnight panel.
Features
Two sets of Form C contacts.
Contacts are rated at 2A @ 30
VDC or .6A @ 120 VAC.
Up to 127 relays can be used on
each SLC loop.
Relay programming is
completely flexible—can be
mapped to zone conditions.
Polling LED visible through
cover plate.
Specifications
Contact Rating: Form C
2A@30VDC
.6A@ 120 VAC
Standby Current:, '.55 mA'
'Alarm Current:, .55 m
Ambient 32°F to 120°F
Temperature (0°c to 49°C)
Mounting 4-square electrical box
c:
f
Model SD500-ARM
Approvals
UL listed, complies with
NFPA 72.
CSFM approved
MEA Approved, 429-92-E,
Vol. 9
FM approved
Compatible Control
Panels
5820XL
5808
5700
'Model SD500-ARM',
Addressable Relay Module
Engineering Specifications
The contractor shall furnish and install where indicated on the plans, addressable relay
modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent
Knight's lntelliknight FACPs.
The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6
amp at 120 VAC.
The relay module must be suitable for mounting in a standard 4-square electrical box and
must include a plastic cover plate. The relay module board must provide an LED that is
visible from the outside of the cover plate.
The relay must be fully programmable for such applications as are required by the
installation.
FRONT VIEW
4-7/8" 1/4" F:
1"
Model SD500-ARM Addressable Relay Module Dimensions
SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA
KNIGHT to keep our product information up-to-date and accurate. We cannot cover
all specific applications or anticipate all requirements. All specifications are FORM# 350218 Rev. D
subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610. © 2010 Honeywell International Inc.
Phone: (800) 328-0103, Fax: (203) 484-7118. www.siIentknight.com
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. ,7306-0559:0132 Page 1 of 1
CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICE
LISTEE: 'SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927
Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464
Email: mike. mcisaachoneywell.com
DESIGN: Model SD500-ARMReIay Module and%D500:AlM SD500-MIM Addressable Input Modules*.
Models SD500-ARM provides inputs for a control unit communication circuit and have two
sets of dry relay contacts. Models SD500-AIM and -MlM provide additional input circuits*.
Refer to listee's data sheet for additional detailed product description and operational
considerations.
RATING: SD500-ARM: 120 VAC, 30 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listees name, model number, electrical rating and UL label.
APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm
control units. Refer to listee's Installation Instruction Manual for details.
*Rev. 03-11-10fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2012 ,Listing Expires, June 30, 2013
Authorized By: JASON DEWITT, Deputy State Fire Marshal
Fire Engineering Division
'SD500-PS and SD500-PSDA
Addressable Pull-Station
lntelliKnight's'addressable pull stations
combine fast response with pin-point
location ID.
The b5OO-PS andSD500-PSDA are a single action or dual action addressable manual fire alarm pull station
for use with Silent Knights lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA
provides a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes
each manual pull station by its specific address saving precious seconds in determining the location of an alarm.
The SD500-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and
lasts.
Combine all this with the features you've come to expect from Silent Knight - easy installation and stable
operation - and it adds up to a flexible solution for all your fire protection needs.
'Model SD500-PS &
SD500-PSDA
Addressable Pull
Station'
The SD500-PS is a single action
addressable fire pull station, and
the SD500--PSDA is a dual action
addressable fire pull station. The
SD500-PS/PSDA feature rugged
metal construction A terminal strip
on back of the pull station allows
interconnection of the pull station to
the SLC of an IntelliKnight control
panel. The SD500-PS/PSDA is
designed for indoor use in non-
explosive environments. The
normally open initiating point
contacts are gold-plated to avoid
risk of corrosion. The SD500-
PS/PSDA has been tested by UL
for compliance to the requirements
of the Americans with Disabilities
ACT (ADA).
Features
UL Listed
CSFM listed
ADA compliant
Key reset (Same key as Silent
Knight enclosures)
Surface mount back box
available
Terminals - accept up to 14
gauge wire
Extremely easy to operate
Corrosion-resistant gold-plated
contacts.
Reflective label makes it easier
to locate in low light
Operation
The SD500-PS/PSDA single action
pull stations are operated by a pull
on the front pull cover of the
station. A plunger switch, wired to
a self contained addressable
module, is released as the pull
station opens to initiate the alarm.
Once operated, the cover hangs
down and can be seen up to 100
feet away. The pull station is reset
by returning the front cover to the
normal upright position and
relocking the station with a reset
key. The reset keys are the same
keys used on Silent Knight
enclosures.
The SD500-PS/PSDA includes a
status LED which blinks, indicating
that the addressable module is
communicating with the loop. The
status LED lights continuously
during an alarm. A dip switch on
the addressable module is used to
set the unique address.
Specifications
'Operating Voltage: 24VbC
Standby Current: '.55mA
'Alarm Current' 155mA'
OIO
AIM
All?I
.d
SD500-PS
Ambient Temperature: 32°F to 120°F
(0°C to 49°C)
Mounting: Single gang
box -
Optional Red Surface Mount Box PS-SMBB
SILENT
___
KNIGHT
SD500-PSand SD500-PSDA
Addressable Pull-Station
Engineering Specifications
Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14
gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and
be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on
the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the
key shall match the control panel.
Manual station shall contain four terminal blocks with two connected to the addressable module and two connect
to the SLC loop. Manual station shall provide data to the control panel with an ID address programmed by dip
switch settings
Manual stations shall be Underwriters Laboratories Inc. listed and installed within the limits defined in the
American Disabilities Act.
FACP
LJ
II
Lt 'v rAc' 5Lr. -
Wiring
Mir
Mounting to Single Mounting to Optional
Gang Electrical Box Surface Mount Box
SAMS-
SD500-PSDA
t 4
ElrvVi,.al Duo must be Installing SD500-LK Dimensions
SILENT
KNIGHT
7550 Meridian Circle, Maple Grove, MN 55369-4927
800-446-6444 or in Minnesota 763-493-6435
FAX: 763-493-6475
World Wide Web: http://www.silentknight.com
MADE IN AMERICA
FORM# 350342, Rev. 09/03
Copyright 0 2003 Silent Knight
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7150-0559:0136 Page 1 of 1
CATEGORY: 7150— FIRE ALARM PULL BOXES
LISTEE: 'SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927
Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464
Email: mike. mcisaac@honeywell.com
DESIGN: Model PS-SKSA andSD500-PS fire alarm pull boxes.Refer to listee's data sheet for
additional detailed product description and operational considerations.
RATING: 30 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in a manner acceptable to the authority having jurisdiction.
MARKING: Listees name, model number, electrical rating and UL label.
APPROVAL: Listed as fire alarm pull station use with separately listed compatible fire alarm control units.
For indoor use only.
* These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and
California amendments.
*Updated 08-29-2011 mt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineenng staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2012 'Listing Expires June 30, 2013'
Authorized By: JASON DEWIIT, Deputy State Fire Marshal
Fire Engineering Division
(Model 5495' 13
SILENT 'Distributed Power Module
0
- / KNIGHT
In an emergency,
by Honeywell you need maximum power
The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply
available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for
appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday - what you need to drive power-
hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years
ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive
linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it
integrates into current systems without the costly investment in new components.
For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent
Knight today for more information at 1-800-328-0103.
aii rA,r uvuuuei 5,495 LU IIU1I-eSStIILIdI high-current
Distributed Power Module accessories like magnetic door
holders
The 5495 is a 6 amp notification power Built-in synchronization for expander that provides its own AC appliances from System power connection, battery charging Sensor®,Gentex®, AMSECO®, circuit, and backup battery for use with Wheelock and Faraday fire and security controls such as the
Silent Knight Model 5208 Fire Control Stand alone operation
/Communicator. The 5495 is the Cost- Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the Costs Americans with Disabilities Act (ADA). Operates with most polarized, UL The 5495 has built-in ANSI cadence Listed notification devices pattern, which can upgrade older
control panels that lack cadence ANSI Cadence pattern output
capability. capability built-in
Features
UL Listed for 6 amps of notification
power
Power supply's advanced switch
mode design reduces damaging
heat and manages power up to 50%
more efficiently than other systems
Dip switches allow for easy
reconfiguration
24 VDC filtered output voltage
Four power-limited notification
outputs; 2 Class A or 4 Class B, or 1
Class A and 2 Class B
Additional continuous auxiliary
output
3 amps per output circuit
2 inputs; 2 Class B or 2 Class A
Ground fault detector/indicator
Independent trouble relay
AC loss delay option shuts off power
Connection to Local Fire Control
The 5495 may be connected to a local
fire Control which utilizes Class A or
Class B type notification circuits
operating between 9 and 32 VOC. The
control panel's notification circuit is
connected to one of the inputs on the
5495. The Control panel's notification
circuit end-of-line resistor is also
connected across two terminals on the
5495, which provides supervision
between the 5495 and the fire control
panel. Polarized audible and/or visual
notification devices are then Connected
to the 5495 signal circuits using the
4.7kc end-of-line resistors provided.
Since the 5495 draws very little power
from the control, it is possible to
connect one 5495 to each notification
circuit on the control panel and still
provide full supervision of the
notification circuits all the way back to
the control panel.
Model 5495
Distributed Power Module
Approvals
UL Listed
MEA429-92-E Vol XII
CSFM 7300-0559123'
NFPA 72
Model 5495
Distributed Power Module
Model 5495 Block Diagram
Signal Circuit Output Signal I
Input
Signal Circuit Output Signal 2
Input
(Optional)
120 VAC
Local Fire Control
Signal I
Distributed Signal 2
Power
Module 5495 Signal 3
Signal 4
Aux. Power
Trouble Output
(Alternative to notification
circuit trouble.)
Supervision Current: Input
The 5495 supervises a variety of 'Standby' 75 mA voltage range: 9 - 32 VDC
functions including: Alarm, 205 mA' Battery charging',
Low AC power Auxiliary apacity, 35.0 AH
Low battery condition power circuit: 1 Ambient temp.: 320 to 1200 F
Earth ground fault Notification (0° to 490 C)
Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) X 40.64 cm H x output (1 Class A& 7.62 0 cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on: Green condition on the host control signal
circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow
5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC Aux trouble: Yellow addition, the 5495 provides a Form @ 3.0 amps each,
C trouble relay output as an 4.7 kQ EOL Output troubles (1-4): Yellow
alternative to using the notification resistor required Ordering Information
circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification
No. of inputs 2 AC input: 120 VAC at 2 amps
Output: 24 VDC at 6 amps Input
configuration: 2 Class B or 2
Class A
r' SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all IJ KNIGHT specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev 0 subject to change without notice. For more information, contact Silent Knight
by Honeywell 12 Clintonville Road, Northford, CT 06472-7161 Phone: (800) 328-0103, © 2010 Honeywell International Inc.
Fax: (203) 484-7118. www.silentknight.com
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION imp 01 "ria-i"I
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7300-0559:0123' Page 1 of 1
CATEGORY: 7300-- FIREALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES
LISTEE: 'SILENT KNIGHT 5ECUR1TY7550 Meridian Circle, Maple Grove, MN 55369-4927
Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464
Email: mike. mcisaachoneyweII.com
DESIGN: Models 5395, 5495 'and *5499 Distributed Power Module (Indicating Circuit Expander). Unit
is power-limited and consists of an enclosure, printed circuit board, terminal boards,
end-of-line resistors and two 12VDC, 7Ah rechargeable batteries. The unit provides up to 4
indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed
product description and operational considerations.
RATING: Input 120 VAC, 2A, 60 hz
Output: 24 VDC
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances
and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24
hour battery back-up as required per code.
MARKING: Listee's name, model number, electrical rating and UL label.
APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating
devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a
distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If
required, models 5395 must be use with fire alarm control unit or indicating signaling devices
that can produce the temporal code pattern. Refer to listee's Installation Manual for details.
NOTE:
*Rec 08-17-2006 jw
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2012 f \ I Listing Expires June 30, 2013:
Authorized By: JASON DEWITT, Deputy State Fire Marshal
Fire Engineering Division
Notification
Multiple Voltages
3 Audible Settings
90, 95, 99 dB
£i 4 8 Candela Settings
Wall - 15/1575/30/75/95/110/135/185
Ceiling - 15130160/75/95/1151150/177
Universal Mounting Base U Ceiling and Wall
Mounts to 5 Backbox Types
Environmentally Friendly
Low Current Draw
Strobe, Horn Strobe, and Horn
Notification Appliances,
Description:
The Wheel ock5 ExcederTM Series of notification appliances feature
a sleek modern design that will please building owners with reduced
total cost of ownership. Installers will benefit from its comprehensive
feature list, including the most candela options in one appliance,
low current draw, no tools needed for setting changes, voltage test
points, 12/24 VDC operation, universal mounting base and multiple
mounting options for both new and retrofit construction.
The Wheelock5 ExcederTM Series incorporates high reliability and
high efficiency optics to minimize current draw allowing for a greater
number of appliances on the notification appliance circuit. All strobe
models feature an industry first of 8 candela settings on a single
appliance. Models with an audible feature 3 sound settings (90, 95,
99 dB). All switches to change settings, can be set without the use
of a tool and are located behind the appliance to prevent tampering.
Wall models feature voltage test points to take readings with a
voltage meter for troubleshooting and AHJ inspection.
The Wheelock5 ExcederTM Series of wall and ceiling notification
appliances feature a Universal Mounting Base (UMB) designed
to simplify the installation and testing of horns, strobes, and
combination horn strobes. The separate universal mounting
base can be pre-wired to allow full testing of circuit wiring before
the appliance is installed and the surface is finished. It comes
complete with a Contact Cover for protection against dirt, dust, paint
and damage to the contacts. The Contact Cover also acts as a
shunting device to allow pre-wire testing for common wiring issues.
The Contact Cover is polarized to prevent it from being installed
incorrectly and prevents the appliance from being installed while
it is on the UMB. When the Contact Cover is removed the circuit
will show an open until the appliance is installed. The UMB allows
for consistent installation and easy replacement of appliances if
required. Wall models provide an optional locking screw for extra
secure installation, while the ceiling models provide a captivated
screw to prevent the screw from falling during installation.
- Save up to 48% in current draw*
- Up to 9 models now in 1 appliance
- Save up to 14% cost of installation**
Sleek Modern Aesthetics
Finger Slide Switches
Voltage Test Points
Compatibility and Requirements
- Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock' Patented Sync Protocol
- Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage
- Strobes produce 1 flash per second over the 'Regulated Voltage" range
'Compared to competitive models " Patented
"Compared to previous models
NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters.
A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING
OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION
INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,
INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND
SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
General Notes:
Genera' Notes:
Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range.
All candela ratings represent minimum effective strobe intensity based on UL Standard 1971.
Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and
maximum humidity of 93% (± 2%) UL 464(85% UL 1971).
Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only).
Horn Strobe Ratings'per UL 1971 & Anechoic at 24 VDC
UL Max Current-' Anechoic dBA at 99
24VDC 12 VDC
Model Regutated Voltage 15J 15/75 3& 60 75 °95 110 115 135 150 177 185 15 15/75 Range VDC
HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159
HSC 8.0-33.0 (1082' b.i02 0.141 :0.148' O.i76 ••••E 0.197 0.242'; :0.282' • 0.125 •••
______
7VDC 7Model
24VDC 12VDC
Regulate
Rang 15 15/75 30 60 75 95 110 115 185 15 15/75
HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186
135 150L
0.272
0.230 0.272 0.122 0.153
F/SC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.122
UL Max Current* at Anechoic 90 dBA
24VDC 12VDC
Model Regulated Voltage
RangeVDC 15 15/75 30 60 75 95 110 115 135 150 185 15 15/75
HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226
F0.267
0.267 0.120 0.148
HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.120
HornRatings per UL Anechoic
Model Regulated Voltage
Range VDC 99dB 95dB 90dB
F/N 16-33.0 0.064 0.044 0.022
HNC 16-33.0 0.084 0.044 0.022
HN 8.0-17.5 0.047 0.026 0.017
HNC 8.0-17.5 0.047 0.026 0.017
* UL may current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the
UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the
maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions.
Specification & Ordering Information
NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance
with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions.
Notification Wheelock° (JWDC) SAFEPATW WAV
Architects and Engineers Specifications
The notification appliances shall be Wheelock' Exceder" Series HS Audible Strobe appliances, Series ST Visual Strobe appliances
and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency
Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard
464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with
standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC.
Indoor wall models shall incorporate voltage test points for easy voltage inspection.
The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated
Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design.
Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110,
135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting
the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with
75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible
location at all times when installed.
The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal
(Code 3) audible outputs.
The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow
mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire
appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to
attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of
an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same
base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible.
The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58W x 2.19" D. Series HN wall shall measure 5.24"
H x 4.58" W x 1.6" 0. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series
HNC ceiling shall have a diameter of 6.68" x 1.50" D.
When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock® Power Supplies
or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any
time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1)
flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced
while maintaining strobe activation when used with Wheelock® synchronization protocol.
Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM
Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM
WE ENCOURAGE AND SUPPORT NICET CERTIFICATION
3 YEAR WARRANTY
Exceder - Spec Sheet 6/11
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. 7125-0785:0168 Page 1 of 1
CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING lMPAIREb
LISTEE: Cooper Wheelock lnc7246 16th St. E., Ste. 105, Sarasota, FL 34243
Contact: Tom Conover (941) 487-2336
Email: thomas.conover@cooperindustries.com
DESIGN: Exceder Series: Models ST strobe, HS horn strobe'and HN horn. Model ST is a synchronous
and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an
audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be
added for ceiling models and/or a '-NR' may be added for non-resettable models. For non
-NR models and optional '5' for silver fascia may be added*. Refer to listee's data sheet for
additional detailed product description and operational considerations.
RATING: Electrical: 12 VDC/24VDC/FWR
Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185
Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177
INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances
and in a manner acceptable to the authority having jurisdiction. All models are for indoor use
and for wall mount only or ceiling mount only*
MARKING: Listee's name, model number, electrical/candela rating, and UL label.
APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when
used with separately listed electrically compatible fire alarm control units. Refer to listee's
Installation Instructions Manual for details.
*Rev. 9-24-09 fm
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineenng staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2012 4Jsting Expires. (June 30, 2013'
Authorized By: JASON DEWI1T, Deputy State Fire Marshal
Fire Engineering Division