Loading...
HomeMy WebLinkAbout2210 FARADAY AVE; ; FA110021; Permit10/28/21, 8:45 AM FA110021 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2210 FARADAY AV Permit Type: FALARM Parcel No: 2121205500 Lot #: 0 Permit No: FAII002I Status: ISSUED Applied 3/10/2011 Approved: 3/11/2011, Reference No.: Issued: 3/11/2011 PC #: Inspector: Project Title: NEMKO FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: Owner: FARADAY POINTE-CA LLC C/O JEANNE ALLEN P 0 BOX 4900 SCOTTSDALE AZ Fees ($) Add'I Fees ($) Total ($) Balance ($) 125 0 125 1 0 1/1 FILE COPY FIRE ALARM SUBMITTAL PROJECT NEMKO 2210 FARADAY AVE., SUITE 150 CARLSBAD,CA 92008 FUEGO ENGINEERING & DESIGN LLC P.O. BOX 212731 CHULA VISTA CA, 91921 OFFICE: (619)796-3360 CELL: (619) 610-8637 PERPARED FOR: CHULA VISTA ALARM 6175 PROGRESSIVE AVE SAN DIEGO, CA 92154 OFFICE: 619 585-9111 FILE COPY PROJECT: NEW 2210 FARADAY AVE., SUITE 150 CARLSBAD, CA 92008 Model Number Description CSFM# 5808 SILENT KNIGHT FIRE ALARM CONTROL PANEL (EXISTING) 7165-05590142 SK-MINIMON SILENT KNIGHT MINI- MONITOR 7300-0559:0155 SK-RELAY SILENT KNIGHT RELAY MODULE 7300-0559:0155 AM FUEGO ENGINEERING & DESIGN LLC PERPARED FOR: CHULA VISTA ALARM 1 P.O. BOX 212731 6175 PROGRESSIVE AVE CHULA VISTA CA, 91921 SAN DIEGO, CA 92154 OFFICE: (619)796-3360 OFFICE: 619 585-9111 CELL: (619) 610-8637 '0 lntelliKnight® 5808 KNIGHT Single Loop Addressable re Alarm System by Honeywell The convenience of an addressable fire alarm control panel in a cost-effective easy to use package. lntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator system. 5808 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description _ The basic 5808 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5808 supports Hochiki or SK protocol devices. 5808 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Built-in support for up to 99 SK detectors and 99 SK modules Built in support for 127 Hochiki devices Up to 125 zones and 125 output groups Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC Distributed, intelligent power Drift compensation 13 pre-programmed output cadences, (including ANSI- 3.41), and 4 programmable outputs Notification circuits can be configured as 2 Class A (Style Z) or 4 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interface for programming via a PC Upload or download programming, event history, or detector status via remote or direct connection Improvements in SKSS deliver five times faster upload/downloads Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor®, and Wheelock® One Form C trouble relay rated at 2.5A at 27.4 VDC and two Form C programmable relays rated at 2.5A at 27.4 VDC Model 5808 Programmable date setting for Daylight Saving Time Plex-2 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Integrated dead front panel protects operator from exposure to electrical components The FACP enclosure features a Plexiglass® viewing window to protect annunciator Acknowledge function allows operator to keep track of event status Installation The 5800 can be surface or flush mounted. Compatibility The 5808 SLC supports multiple device types of the same protocol: SK (System Sensor) Hochiki You cannot mix Hochiki and SK devices on a FACP. .4 Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.75A Total Accessory Load: 6A © 27.4 VDC Notification Power: 6A @ 27.4 VDC, power-limited Standby Current: 170 mA Alarm Current: 325 mA Notification & Auxiliary Circuits: 3A @ 27.4 VDC per circuit,power- limited Battery Charging Capacity: 7.0-35 AH Battery Size: 18 A max. allowed in FACP. Larger capacity batteries can be housed in an RBB accessory cabinet Physical Flush Mount Dimensions: 14.5' W x 24.75" H x 3.5" D (36.8 W x 62.9 H x 8.73 D cm) Overall Dimensions: 16" W x 26.4" H x 4.65" D (40.6W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable Miscellaneous Accessories 5660 Silent Knight Software Suite PC-base software for FACP programming. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-2 Door Dead front cabinet door with clear window to limit access to the FACP, RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D(406 mm W x 254 mm H x 152 mm D) Hochiki and SK Devices See the specification sheets listed below for a complete listing of the Hochiki and SK devices. 53624 Hochiki Devices data sheet 53623 SK Device Protocol Devices data sheet lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight 5808 for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signalling services. UL Listed CSFM 7170-0559:142; MEA 429-92-E Vol. XIV S-BUS Accessories 5860111 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5808. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power-limited notification appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. I]-. This document is not intended to be used for installation purposes. We try to SILENT keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7116. www.silentknight.com MADE IN AMERICA 350386 Rev. G © 2010 Honeywell International Inc. I. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0142 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywelI.com DESIGN: Models *5808 *lFp100 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterilow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5808, IFP-100 Control Units *01 FP-1 OOBD Motherboard 7628 EOL Resistor 5860/5860R1RA-1000 Annunciator *0IFP1 00 IA IFP-100 User Interface *058631 5808 User Interface 5496 Power Module 5824 Serial/Parallel Interface RPS-1000 Power Expander/Supply 5865-3/5965-4 LED Annunciator p 5880 LED 10 Module 5883 Relay Interface Board SD500-ANM Addressable Notification Module SDSOO-LIM Line Isolation Module 5D505-61B Isolation Base SD-500 SDM Smoke Detector Module RA-100 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module *122740 *122723E Enclosures RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. Rev. 10-3-08 ma *Tt ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an \.F endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0142 Page 2 of 2 NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev. 10-3-08 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an -/ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational cfr requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division SK-Minimon Specifications Compatibility D SILENT KNIGHT by Honeywell SK-Minimon Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight lntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103. 'S Description The SK-Minimon is an addressable monitor modules for use with the lntelliKnight fire alarm control panels (FACP5). The SK-Minimon acts as an interface to contact devices, such as waterfiow switches and pull stations. The SK-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. Features Single contact monitor SK-Minimon support for Class B (Style B) contact monitor wiring Small and lightweight size allows for flexible mounting options Rotary address switches for fast installation UL listed Electrical Standby Current: 400 uA max 24 VDC with comm. Voltage Range: 15 - 32 VDC End of Line Resistance: 47 k Ohms Physical Dimensions: 2.75" W x 1.3" H x 0.5" D Weight: 1.2 oz (37 g) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing The SK-Minimon is compatible with the following IntelliKnight FACP's: 5700 5808 5820XL Approvals UL approved CSFM FM Approved a SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight FACPs. The device shall be capable of Styles A and B supervised wiring to the load device. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. Other Devices Wiring the SK-Minimon D SILENT This document is not intended to be used for installation purposes. We MADE IN AMERICA try to keep our product information up-to-date and accurate. We cannot KNIGHT cover all specific applications or anticipate all requirements. All FORM# 350133 Rev B specifications are subject to change without notice. For more information, by Honeywell contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 © 2010 Honeywell International Inc Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknight.com U CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 --MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models IDP-Relay-6, SKRelay6*, relay module, IDP-Control-6, SK Control.6*, supervising control module, IDP-Monitor-10, SKMon10*, input monitor module, lDP-Zone-6, SKZone6* six zone interface module, IDPMonitor*, lDPMinimon*, IDPZone*, SKMonitor*, SKMinimon*, SKZone* monitor modules, I DPControl*, IDPRelay*, SKControl*, SKRelay*, control modules, I DPMonitor2*, and SKMonitor 2*, dual monitor modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in ranner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SKZone6* and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 07-14-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an \J/ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 I Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division SK-Relay Intelligent Relay Module * k The SK-Relay Module is intended for use in intelligent, two-wire systems where the individual address of each module is selected using the built in rotary switches. - A For more information about the lntelliknight system, or to locate you nearest source, please call 800-328-0103 or in Connecticut, call (203) 484-7161. Description The SK-Relay is an addressable relay module for use with Silent Knight lntelliKnight series fire alarm control panels - - (FACPs). ' The SK-Relay allows a Silent Knight FACP to switch discrete . *. contacts by code command. The relay contains two isolated .1 sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The SK-Relay contacts can be used for virtually any normally open or normally closed application. Each SK-Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the SK-Relay, the relay is triggered by the FACP. Features Two sets of Form C contacts Rotary address switches for fast installation Contacts are rated for a variety of amps (see Specifications) Panel controlled status LED that flashes green in normal state and is solid red in alarm Relay programming is completely flexible—can be mapped to zone conditions Polling LED visible through the cover plate Attractive ivory cover plate SEMS screws for easy wiring UL Listed Installation The SK-Relay mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight Compatibility The SK-Relay is compatible with the following lntelliKnight FACP's: 5700 5808 5820XL DSILENT KNIGHT by Honeywell do SK-Relay Model SK-Relay If Any Wiring to Terminals 3 —9 Is Not Power Limited, the CB500 Barrier Is. Required. The CBSOO Includes a Non-Power Limited Label, Which Must Be Placed Over the Power Limited Terminal Information on the Name Plate Label To Next Device n 17-1 ro 0 oj Relay Common 2 ... ° Normally closed 2 Normally Open 2 Relay Common 1 : L. I Normally Closed 1 5.- - From Compatible FACP + or Previous Device Module Does Not Supervise I I I Normally Open I Controlled Circuits Wiring the 5K-Relay Module Specifications End-of-Line Resistance: not used Physical Standby Current: 300 pA max @ 24 VDC (one Height: 4.65" communication every 5 sec with LED enabled) Width: 4.25" LED Current: 5.5 mA (with LED latched on) Depth: 1.1" SLC Loop Resistance: 40Q max. Shipping Weight: 6.3 oz (196 g) Relay Contact Ratings Electrical 3.OA @ 30 VDC resistive Operating Voltage: 15 —32 VDC 0.9A @ 110 VDC resistive Current Draw: 6.5 mA max (LED on) 0.9A @ 125 VAC resistive Operating Current: 0.5A © 125 VAC inductive (PF = .35) 230 pA (LED flashing) direct poll 0.7A @ 75 VAC inductive (PF = .35) 255 pA (LED flashing) group poll D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight FORM# 350127 Rev A by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, © 2009 Honeywell International Inc. Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 --MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models lDP-Relay-6, SKRelay6*, relay module, IDP-Control-6, 5K Control6*, supervising control module, IDP-Monitor-1 0, SK-Mon-1 0*, input monitor module, IDP-Zone-6, SKZone6* six zone interface module, IDPMonitor*, lDPMinimon*, lDPZone*, SKMonitor*, SKMinimon*, SKZone* monitor modules, IDPControI*, I DPRelay*, SKControl*, SKReIay*, control modules, IDPMonitor2*, and SK.Monitor 2*, dual monitor modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SKZone6* and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 07-14-09 fm , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed \ the test results and/or other data but does not make an independent verification of any claims. This listing is not an \/ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 a ) Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division