Loading...
HomeMy WebLinkAbout891 PALOMAR AIRPORT RD; KSK 3; FPC2019-0063; PermitPERMIT REPORT (ity of Carlsbad Print Date: 11/03/2021 Permit No: FPC2019-0063 Job Address: 890 PALOMAR AIRPORT RD, # KSK 3, CARLSBAD, CA 92011-4443 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fixed Extinguishing Syste Parcel #: 2110213600 Track U: Applied: 03/14/2019 Valuation: $981,155.20 Lot U: Issued: 07/17/2019 Occupancy Group: Project U: Finaled Close Out: 11/03/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: CROSS ST CHICKEN & BEER KIOSK 3 -NEW HOOD UL-300 SUPPRESSION SYSTEM FPContractor: SAN DIEGO FIRE PROTECTION 1934 BONUS DR SAN DIEGO, CA 92110-1325 (619) 251-7241 FEE AMOUNT FIRE Hood & Duct Extinguishing System Initial Sys $417.00 Total Fees: $417.00 Total Payments To Date: $417.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Kitchen Mister Restaurant Cooking Area Fire Suppression System TECHNICAL MANUAL Components Design Installation Maintenance Recharge Buckeye Fire Equipment BFR-TM 110 Kings Road ULEX 6885 ULC-EX 6885 Kings Mountain, NC 28086 January 1, 2013 Chapter 1 General Information Chapter 1 - General Page 1 - 1 Revision 5 Introduction The Buckeye Fire Equipment Kitchen Mister Fire Suppression System is a pre-engineered wet chemical restaurant fire suppression system as defined by the NFPA-17A Standard for Wet Chemical Extinguishing Systems. It is designed to protect commercial restaurant cooking appliances, hoods, and ducts as described in this manual. Installation and maintenance of the Kitchen Mister System must be in compliance with the parameters set forth in this manual and be performed by a factory trained, Authorized Buckeye Fire Equipment Distributor. CAUTION This technical manual can in no way be considered sufficient to completely understand the proper design, installation, and/or maintenance of the Kitchen Mister System. Buckeye Certified Training is required to become Authorized to perform these procedures. Buckeye Fire Equipment will not be responsible for system(s) designed, installed, or maintained by individuals or companies not trained and Authorized by Buckeye Fire Equipment. How the Kitchen Mister Works The Kitchen Mister System utilizes a potassium based liquid fire extinguishing agent specifically designed for grease laden fires such as those associated with restaurant cooking areas. The Kitchen Mister agent works to suppress commercial kitchen fires in three ways: The agent interrupts the chemical chain reaction causing combustion, thus extinguishing the fire. The agent is discharged in a very fine mist, cooling the fire to below its auto-ignition temperature. The agent reacts with grease to form a foam-like layer commonly called saponification that starves the fire of oxygen, stopping combustion and preventing re-ignition. The system will automatically actuate upon detection of a fire or can be manually actuated by using a remote manual pull station positioned at the point(s) of egress from the hazard area. When the system is actuated, a pre-determined amount of fire extinguishing agent is discharged through the piping network and fixed nozzles to the duct, plenum, and cooking appliances. The agent is discharged as a very fine mist that quickly acts to suppress grease laden fires. System Temperature Limitations The operating temperature range of the Kitchen Mister System is 32°F (0°C.) minimum to 120°F (490C.) maximum. Listings and Approvals The Kitchen Mister Fire Suppression System is Listed and Approved by the following agencies: Underwriters Laboratories, Inc. (Listed to the requirements of UL-300/UL-1254) UL-EX 6885 Underwriters Laboratories of Canada, ULC-EX 6885 Approved by the New York City Fire Department COA# 5550 ISO-9001 Registered Manufacturers Warranty Buckeye Fire Equipment warrants the Kitchen Mister System against defects in material and workmanship for a period of one year from date of shipment to the purchaser under normal use and service. Buckeye Fire Equipment is not responsible for the installation and maintenance of the system. All warranty claims must be filed with Buckeye Fire Equipment within 30 days of the discovery of the defect to be valid. System Installation and Maintenance Reciui rements Any individual installing or performing maintenance on the Kitchen Mister System MUST be; fully trained and Authorized by Buckeye Fire Equipment, have a complete understanding of this manual in full, and have a complete understanding of all local, state, and federal requirements that may apply. The Buckeye Kitchen Mister System must be installed and maintained in accordance with the NFPA-17A Standard for Wet Chemical Extinguishing Systems, NFPA-96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, this manual, and all applicable local, state, and federal regulations. Buckeye Fire Equipment is not responsible for systems installed or maintained by personnel that are not factory trained and Authorized. BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 2 - Components Page 2-4 Revision 5 Figure 2-8. Model MB-2, Shown With BFR-20 Cylinder Remote Mechanical Pull Station The Model RPS-M Remote Mechanical Pull Station provides remote mechanical actuation of the Systems Releasing Module. It is connected to the Systems Releasing Module with: 1/16" (0.16 cm) stainless steel cable enclosed in 1/2" (1.3 cm) EMT conduit with a corner pulley at each change of direction. Buckeye Shielded Cable which does not require a corner pulley at each change of direction or conduit. A combination of both. A remote pull station .is required at the point of egress from the hazard area being protected. See Figure 2-9. Figure 2-9. Model RPS-M, Remote Mechanical Pull Station Mechanical Gas Shutoff Valves A gas shutoff valve is required for all systems protecting gas fueled appliances. A mechanical means of stopping gas flow is provided by the Models BFGV-75 /100 /125 I 150 I 200 / 250 I 300 Gas Shutoff Valves. It is connected to the Systems Releasing Module with: 1/16" (0.16 cm) stainless steel cable enclosed in 1/2" (1.3 cm) EMT conduit with a corner pulley at each change of direction. Buckeye Shielded Cable which does not require a corner pulley at each change of direction or conduit. A combination of both. The valves are rated for natural or LP gas (see Figure 2- 10) and are available in the following sizes: Model Number Valve Size In (cm) Maximum Operating Pressure BFGV-75 %(1.9) 5 psi (.4 bar) BFGV-100 1(2.5) 5 psi .4 bar) BFGV-125 1 1/4 (3.2) 5 psi .4 bar) BFGV-150 1%(3.8) 5 psi .4 bar) BFGV-200 2(5.1) 5 psi .4 bar) BFGV-250 2 ¼ (6.4) 5 psi .4 bar) BFGV-300 3(7.6) 5 psi .4 bar) Note: Gas valve size must be no smaller than the size of the gas line it is connected to. 00 o EUM o o Figure 2-10. Model BFGV-XXX, Mechanical Gas Valve [NCASEOF (1) FIRE PULL HANDLE HARD ACTU FIRE SU SYSTEM a) jV RPS-M a) ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 i!l (5.16 cm) STAINLESS DETECTION CABLE !ISLE Fusible Link Bracket Kit The Model FLB-1 Fusible Link Bracket kit (see Figure 2- 11) includes the following: Standard high profile 10° (25 cm) fusible link bracket. Two (2) ½" (1.3 cm) EMT connectors. Two (2) cable crimps. Two (2)'S" hooks. Note: Fusible links must be ordered separately. FUSIBLE LINK BRACKET 7 (1.3 cm) EMT J CONNECTOR —:ABLE CRIMP Figure 2-11. Model FLB-1, 10" (25 cm) Fusible Link Bracket Assembly Fusible Link Holder The Model FLH Fusible Link Holder is designed to allow for the use of a continuous fusible link line, thus eliminating the need to cut and crimp each individual fusible link. They can be used either with or without fusible link brackets. They are available in packages of 25 (Model FLH-25). See Figure 2-12. STYLE) Figure 2-12. Model FLH, Fusible Link Holder Fusible Links The Kitchen Mister System uses Globe ML Fusible Links for automatic system activation. See Figure 2-13. Fusible links are designed to separate at specific temperatures, releasing tension from the fusible link Chapter 2 - Components Page 2 - 5 Revision 5 detection line and causing system actuation. Correct fusible link selection is an essential element in the design of any restaurant fire suppression system. After performing a temperature study to determine the maximum ambient temperature at the fusible link location, the correct fusible link should be selected from the following chart: Fusible Link Model Number Max. Ambient Temperature FL-280 225° F. (107° C.) FL-360 300° F. (149° C.) FL450 375° F. (191° C.) FL-500 4300 F.(221-C.) Figure 2-13. Globe ML Fusible Link Buckeye Shielded Cable As an alternative to using conduit and corner pulleys to connect the fusible link system, gas valve, and/or remote pull station to the Systems Releasing Module, the Kitchen Mister System utilizes Buckeye Shielded Cable to perform this function. Buckeye Shielded Cable is 1/16" (0.16 cm) stainless steel cable encased in a protective, flexible conduit. See Figure 2-14. Buckeye Shielded Cable requires no conduit or corner pulleys, as the name implies, provided it is installed in accordance with the guidelines set forth in this manual. Model BFR-SC-100 comes with 105 feet (32 m) of flexible conduit with 210 feet (64 m) of 1/16" (0.16 cm) stainless steel cable inside it. BUCKEYE SHIELDED CABLE 1116 )O.16 cm) STAINLESS STEEL CABLE Figure 2-14. Model BFR-SC-100, Buckeye Shielded Cable BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 10 Chapter 2 - Components Page 2 - I Revision 5 Chapter 2 System Components Cylinder Sizes The Buckeye Fire Equipment Kitchen Mister Fire Suppression System has available four (4) cylinder sizes; the Model BFR-5 (5 flow points), Model BFR-10 (10 flow points), Model BFR-15 (15 flow points), and Model BFR-20 (20 flow points). Cylinder sizes are based on the flow point capacity of the cylinder, for example, the BFR-5 is capable of supporting a maximum of five (5) flow points. All cylinders are manufactured, marked, and tested in accordance with DOT 4BW240. Each cylinder is shipped pre-filled with extinguishing agent, and charged with dry nitrogen to a pressure of 195 psig (1344 KPa) @700 F (21° C). Cylinder and valve assembly dimensions are shown in Figure 2-1, Note: Cylinders shall always be stored in an upright position. SRM "A" - r ' B " ,, D ,, C Figure 2-1. Cylinder and Valve Assembly Dimensions. Model Number A inches (cm) B inches (cm) C inches (cm) D inches (cm) Max. Flow Points Weight lbs. (kg) Mounting Bracket BFR-5 24.8 (63) 16.2 (41) 10 (25) 13,4 (34) 5 42 lbs. (19) MB-1 BFR-10 34,4 (87) 25.8 (66) 10 (25) 23 (58) 10 74 lbs. (33) MB-2 BFR-15 1 44.8 (114) 36.2 (92) 10 (25) 1 33.4 (85) 1 15 1 107 lbs. (48) MB-2 BFR-20 1 42.4 (108) 33.8 (86) 12 (31) 1 31 (79) 1 20 1 130 lbs. (60) MB-2 BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 The Model MB-1 Mounting Bracket is used to mount the Model BFR-5 cylinder. See Figure 2-7. Figure 2-7. Model MB-I, Shown With BFR-5 Cylinder The Model MB-2 Mounting Bracket is used to mount the Model BFR-10, Model BFR-I5, or Model BFR-20 cylinders. See Figure 2-8. 10 Systems Releasing Module - SRM The Model SRM Systems Releasing Module is a fully mechanical control head that can be connected directly or remotely to the system valve and is required for system actuation. The Systems Releasing Module will support the following system inputs and outputs: One Fusible Link Detection Line One Gas Valve Line One Remote Pull Station Line Two windows in the front cover of the Model SRM allow for visual verification of the actuation cartridge presence and the status of the puncture pin mechanism. See Figure 2-5. PM NT 0 SRM 0 Chapter 2 - Components Page 2 - 3 Revision 5 Model BFR-AC-L is a larger nitrogen cartridge that can actuate up to five agent cylinder (refer to Chapter 4 of this manual for limitations). See Figure 2-6. 5.12 I' (13 cm) CL 01.57 IIIIiD (4 cm) IN I o1 Model BFR-AC-L 3.70 (9.4 cm) 01.00 (2.5 cm) WEE Model BFR.AC-S Figure U. Model BFR-AC-S and BFR-AC-L, Nitrogen Actuation Cartridges Mounting Brackets / ACTUATION LEVER AND / ACTUAI1ON CARTRIDGE PUNCTURE PIN VIEWING WINDOW VIEWING WINDOW Figure 2-5. Model SRM, Systems Releasing Module The Model SRM can actuate a maximum of three (3) agent cylinders when using the Model BFR-AC-S Nitrogen Activation Cartridge (included with SRM and SRM-D) or five (5) agent cylinders when a Model BFR- AC-L Nitrogen Activation Cartridge is installed. Systems Releasing Module - SRM-D The Model SRM-D (Systems Releasing Module —Dual) is exactly the same as the Model SRM except that it supports a second independent fusible link detection line. Nitroaen Actuation Cartridaes The Kitchen Mister System can use two types of actuation cartridges for system actuation. Model BFR-AC-S is a small nitrogen cartridge (included with System Releasing Module) that can actuate up to three (3) agent cylinders. BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 2 - Components Page 2-6 Revision 5 Shielded Cable Interface The Model BFR-SCI Buckeye Shielded Cable Interface is required for connecting Buckeye Shielded Cable to any standard 1/2" (1.3 cm) EMT conduit connector or corner pulley. See Figure 2-15. Figure 2-15. Model BFR-SCI, Shielded Cable Interface Note: A 3/32" (0.2 cm) hex wrench is required to tighten the set screw. Compression Type Corner Pulley When Buckeye Shielded Cable IS NOT used to connect the fusible link system, gas valve, and/or remote pull station to the control head, a corner pulley is required whenever a change in stainless steel cable direction is necessary. The Model CPCT-1 corner pulley is equipped with a compression type fitting that connects to standard 1/2" (1.3 cm) EMT conduit. See Figure 2-16. Figure 2-16. Model CPCT-1, Compression Type Corner Pulley Model Number Flow Points Band Color N-IHP I Blue N-11P I Red N-2HP 2 Green N-21-P 2 Yellow N-2W 2 White Note: Details on specific nozzle applications can be found in the Design Section of this manual. 13/16 (0.2 cm) HEX. TETHERED / BLOW-OFF CAP COLOR ID BAND tD( 1.50" INTERNAL SCREEN \—RETAINING RING Figure 2-17. Discharge Nozzle Swivel Nozzle Adaptor The Model N-SA Swivel Adaptor can be used with any discharge nozzle to facilitate the nozzle aiming process. They are chrome plated and allow for a 300 rotation of the nozzle in any direction. See Figure 2-18. 3/8" (1.0cm) NPT FEMALE THREAD Discharge Nozzles Misting type discharge nozzles have been specifically developed for appliance, duct, and plenum applications. Each nozzle has a predetermined flow point value and comes equipped with a blow-off cap to protect the end orifice from blockage. Each nozzle is identified by the model number stamped on the nozzle body and has a unique color band for easy visual identification. See Figure 2-17. 30° ROTATION 318 (1.0 cm) NPT MALE THREAD Figure 2-18. Model N-SA, Swivel Adaptor ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 Chapter 2 - Components Page 2-7 Revision 5 Digital Thermometer The Model BFR-DT Digital Thermometer is used to accurately determine the maximum ambient temperature in the plenum in the air stream of each appliance. A thorough temperature survey is necessary for proper fusible link selection. The thermometer comes with a digital readout and remote sensing wand for ease of use. CAUTION A temperature study is required before the installation of any system in order to determine the correct temperature fusible link at each fusible link lOcation. Pipe and Fittings Pipe and fittings must be furnished by the installer. Pipe shall be Schedule 40 black, chrome plated, or stainless steel pipe. Fittings shall be rated 150 LB (68 kg). BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1 2013 Chapter 3 - System Design Page 3- 1 Revision 5 Chapter 3 System Design OVERVIEW OF SYSTEM DESIGN (127 cm) perimeter and a maximum one side length of 12-1/2' (32 cm) (square) and 16-3/4" (43 cm) (rectangular) respectively. It can also protect a round The following chapter will cover the proper design of the duct with a maximum circumference of 50" (127 cm) Buckeye Fire Equipment Kitchen Mister Fire [16" (41 cm) maximum diameter]. See Figure 3-1 & 3-2. Suppression System. It is divided into three sections: Nozzle Coverages and Placements Piping Limitations Detector Placement Design of the Kitchen Mister System must be in compliance with the parameters set forth in this manual and be performed by a factory trained, Authorized Buckeye Fire Equipment Dealer. Buckeye Fire Equipment is not responsible for systems installed or maintained by personnel that are not factory trained and Authorized. NOZZLE COVERAGE, PLACEMENT, AND AIMING This section will give detailed guidelines for determining nozzle type, positioning, and aim point for appliance, plenum, and duct protection. Duct Protection It is not necessary to shut down or damper the exhaust fan for the system to function properly. It is recommended that the exhaust fan be left on during system discharge to help distribute the extinguishing agent throughout the ductwork. Ducts - 50" (127 cm) Maximum Perimeter Nozzle: N-1 LP (1 Flow Point) Coverage: Unlimited length with: 50" (127 cm) Maximum Perimeter with a longest side of 16-3/4" (43 cm) for rectangular ducts and 12-1/2" (32 cm) for square ducts or 50" (127 cm) Maximum Circumference (maximum diameter of 16" (41 cm)) for round ducts. Placement: Centered in duct opening, from 1-6" (2.5- 15 cm) into the duct opening. Aim point: Center of duct. The Model N-ILP nozzle is a one flow point nozzle that can protect a square or rectangular duct of unlimited length and changes of direction with a maximum 50" BPN: BFR-TM Ducts - 150" (381 cm) Maximum Perimeter Nozzle: N-2W (2 Flow Point) Coverage: Unlimited length with: 150" (381 cm) Maximum Perimeter with a longest side of 50" (127 cm) for rectangular ducts and 37-1/2" (95 cm) for square ducts or. 150' (381 cm) Maximum Circumference [maximum diameter of 47-1/2" (121 cm)] for round ducts. Placement: Centered induct opening, from 0-6" (0-15 cm) into the duct opening. Aim point: Center of duct. AIM: CENTER OF FOR DUCTS (VERTICAL OR HORIZONTAL) WTHOUTA TRANSITION AIM: CENTER OF ENTRANCE TO HORIZONTAL DUCT PLACEMENT: 1.6(2.5-15cm) 112L 1"- 0 to 50(0-127 cm), N-1LPJ -. 0" - 6"(0-15 cm) [Per. 0 to 150" (0-381 cm), N-2W] INTO THE DUCT TRANSITION FOR DUCTS WITH A VERTICAL TO HORIZONTAL TRANSITION Figure 3-1. Proper Duct Nozzle Placement ULEX 6885 ULC-EX 6885 January 1, 2013 NOZZLE PLACEMENT: 1"- 6" (2.5-15 cm) Oto 50(0.127 cm), N-1LP] 0" -6" (0-15 cm) o to 150" (0-381 cm), N-2q INTONE DUCT '0 Plenum Protection Nozzle: N-1 HP (1 Flow Point) Coverage: Length: 12 feet (3.7 m) max. Width: 4 feet (1.2 m) max. Placement: See Figure 3.7. Aim point: See Figure 3.7. The Model N-IHP nozzle is a one (1) flow point nozzle that can protect a plenum (either single bank or V-bank) of 12 feet (3.7 m) in length and 4 feet (1.2 m) in width per nozzle. Larger plenums must be divided into 12 foot (3.7 m) sections, with each section protected with a separate nozzle. See Figure 3-7. Plenum: V-bank Nozzle Placement The nozzle must be located at the center of the V-bank width and down 1/3 of the vertical height, within 6 inches (15 cm) of the end of the plenum or plenum module and aimed down the length of the plenum. See Figure 3-7. Plenum: Single Filter Bank Nozzle Placement The nozzle must be located at a point that is 2" (5.1 cm) from the back edge of the filter and 1/3 of the vertical height of the filter, within 6 inches (15 cm) off the end of the plenum or plenum module and aimed down the length of the plenum. See Figure 3-7. V3ANK 12 FT (3Jm)- rT/1 r3.7m) H SINGLE BANK 110 Figure 3-7. Model N-IHP Plenum Nozzle Placement and Aiming Note: These examples are typical and do not represent every acceptable nozzle configuration, only a representative sample of them. Designer Note For plenums that exceed 12 feet (3.7 m) in length and therefore require multiple nozzles, it is recommended that the total length be divided into equally sized protection zones and protected accordingly. So a 16 foot (4.9 m) long plenum should be divided into two 8 foot (2.4 m) zones, with a nozzle protecting each, as opposed to a 12 foot (3.7 m) zone and a 4 foot (1.2 m) zone. BPN: BFR-TM Chapter 3 - System Design Page 3-3 Revision 5 APPLIANCE PROTECTION Each different appliance must be protected in a specific manner with regard to nozzle selection, placement, and aiming. No deviations from these parameters are allowed and failure to comply completely with these requirements will void the UL Listing of the system and may render the system ineffective. In order to properly understand this section, several key terms need to be defined in advance. DESIGN TERMINOLOGY Nozzle Height: The distance from the tip of the discharge nozzle to the top surface of the appliance (except for woks, in which case the bottom of the wok is used). Hazard Area: All nozzle coverages include the maximum size of the hazard area they can protect. Hazard area is NOT the overall size of the appliance being protected, but rather the actual size of the portion of the appliance used for cooking. Appliances Repuirina Multiple Nozzles Some appliances may need to be protected by multiple nozzles because of their size. If the size of an appliance is larger than the approved coverage for that appliance, multiple nozzles must be used. This is accomplished by dividing the hazard area into individual zones that comply with the parameters of the listing for that appliance. In this case, each zone will be protected as an individual appliance with respect to nozzle placement and aiming. RANGE PROTECTION Two (2) Burner Ranae - LOW Proximit Nozzle: N-1 LP (1 Flow Point) Coverage: 12" (30.5 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 16" (41 cm) - 30" (76 cm) Placement: 3" (7.6 cm) from either edge of appliance, on appliance's long centerline. Aim point: 6" (15 cm) from opposite edge of appliance, on appliance's long centerline. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a range cooking area of 12" (30.5 cm) wide by 24" (61 cm) deep. The nozzle must be located 16" (41 cm) to 30" (76 cm) above the cooking surface and positioned on the appliance's long centerline within 3" (7.6 cm) of either the front or back edge of the ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 3 — System Design Page 3-4 Revision 5 appliance. The nozzle must be aimed at the appliance's long centerline 6" (15 cm) off the opposite edge of the appliance. See Figure 3-8. MAXIMUM HEIGHT 30 (76Or,,) NOZZLE PLACEMENT AREA FRONT OR MACIl OF APPLIANCE) - AIM POINTS (loom) FROM RANGE - )CI.- OPPOSITE EDGE NOZZLE LOCATED FROM FRONT OR EACH HAZARD REGE (NGTH 12 MAXIMUM 130.5 Xml HAZARD WIG - 24 (Ri On,) Figure 3-8. Low Proximity, 12" (30.5 cm) x 24" (61 cm) Range Model N-ILP Nozzle Four (4) Burner Ranges: I) Four Burner Range —HIGH Proximity Nozzle: N-1 LP (1 Flow Point) Coverage: 24" (61 cm) x 24' (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 30" (76 cm) —40" (102 cm) Placement: Within 3" (7.6 cm) of the center of appliance. Aim point: Center of appliance. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a range cooking area of 24" (61 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 40" (102 cm) above the cooking surface and within 3" (7.6 cm) of the center of the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-9. MAXIMUM HEIGHT 46(1030m) - NOZZLE r (P.R cm) PLACEMENT FROM AREA CENTER MINIMUM HEIGHT CENTER RANGE S URN ER TO BURNER To LENGTH, BURNER WiDTH: Figure 3-9. High Proximity, 24" (61 cm) x 24" (61 cm) Range Model NA LP Nozzle ULEX 6885 ULC-EX 6885 January 1, 2013 2) Four Burner Ranae — LOW Proximity Nozzle: N-2W (2 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 16" (41 cm) —30" (76 cm) Placement: Center of appliance. Aim point: Center of appliance. The Model N-2W nozzle is a two (2) flow point nozzle that can protect a range cooking area of 24" (61 cm) wide by 24' (61 cm) deep. The nozzle must be located 16" (41 cm) to 30" (76 cm) above the cooking surface and be centered over the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-10. MAXIMUM HEIGHT 30' (76 ern) NOZZLE PLACEMENT AREA MINIMUM HEIGHT 16"(41c) 1 RANGE CENTER BURN BURNER TO BURNEI LENGTH ER 24" (61 cm) Figure 3-10. Low Proximity, 24" (61 cm) x 24" (61 cm) Range Model N-2W Nozzle Six (6) Burner Range Nozzle: N-21-P (2 Flow Point) Coverage: 36" (91 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 35" (89 cm)-43" (109 cm) Placement: Centered over appliance. Aim point: Center of appliance. The Model N-2LP nozzle is a two (2) flow point nozzle that can protect a range cooking area of 36" (91 cm) wide by 24" (61 cm) deep. The nozzle must be located 35" (89 cm) to 43" (109 cm) above the cooking surface and centered over the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-11. BPN: BFR-TM IF SHELF IS HIGHER, THEN NOZZLE HEIGHT MAY INCREASE J PROPORTIONALLY. SHELF M02EMJM MAY BE EXCEEDED IF NOZZLE15 (48 cm) MIN.- TIP IS PLACED BELOW SHELF HEIGHT. AIM: 6 (15 cm) FROM OPPOSITE EDGE, ON LONG CENTER LINE Chapter 3 — System Design Page 3 - 5 Revision 5 Model N-ILP Nozzle 'MAXIMUM HEIGHT 43 1100 cm) NOZZLE PLACEMENT AREA MINIMUM HEIGHTZE (90 cnl) /• RANGE CENTER BURNER TO SURNEJ 00XTF424(EIcn,) J. Figure 3-11. 36" (91 cm) x 24" (61 cm) Range Model N-2LP Nozzle Range I Griddle Combination Appliance Nozzle: N-ILP(1 Flow Point) Coverage: 30" (76 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 30" (76 cm) - 40" (102 cm) Placement: Within 3" (7.6 cm) of the center of appliance. Aim point: Center of appliance. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a combination range / griddle with a cooking area of 30" (76 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 40" (102 cm) above the cooking surface and within 3" (7.6 cm) of the center of the appliance. The nozzle must be aimed at the center of the cooking area. See Figure 3-11. - MAXIMUM HEGHT 40' (102 En) NO ZZ LE 11.6 Cm) PLA AREA CEMENT FROM CENTER MINIMUM HEIGHT 3E"(lECM) RANGERIDDLE CENTER BURNER WOTh 12' cm (36.0 ) MA BUP.NBR TO BURNER TO GRIDDLE URNSPJGRIXGLE GEDTH Em) ..44)3o GRIDDLE LBNOTN I 3E'(7Ecm)l 7 , Figure 3-12. 30" (76 cm) x 24" (61 cm) Combination Range I Griddle BPN: BFR-TM Protection For Appliances With a Back- shelf The protection of an appliance (such as a range) that has a shelf that can interfere with a nozzle discharge can be accomplished by either using the low proximity coverage for that appliance or placing the nozzle in a position within its stated limitation where the discharge pattern will not be affected. Sample coverages for a range with a back-shelf are shown in Figures 3-13 and 3-14. EM ELP WIDTH: NOT TO EXCEED THE CENTERLINE OF THE RANGE UNLESS NOZZLE IS LOCATED UNDER SHELF MAX. HEIGHT: TIP LOCATED BELOW OR LEVEL PLACEMEN1 WITH THE BOTTOM OF THE OBSTRUCTION BUT, .CENTER OF MOTTO EXCEED 30 (lB cm) MIN. HEIGHT 16" (41 cm) NOZZLE TIP MUST BE AIM: CENTER OF BELOW SHELF OR RANGE DESTRUCTION. 6 ___*(30.5 Cm) (30.5 C BURNER ERBURN WiDTH: BURNER TO BURNER (81 cm) 24" LENGTH: (61 Figure 3-13. 24" (61 cm) x 24" (61 cm) Range with Back-shelf Model N-2W Nozzle 11(28 cm) MAX.'" MAX. HEIGHT 24'(61 cm)— MIN. HEIGHT 18 (41 cm)_, RANGE CENT - MAX. HAZARD NOZZLE LOCATED 3" (7.8 LENGTH: 12 (30.5 cm) cm) FROM FRONT EDGE MAX. HAZARD WIDTH: 24" (61 cm) Figure 3.14. 12" (30.5 cm) x 24" (61 cm) Range with Back-shelf Model NA LP Nozzle ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 2 - Components Page 2 - 4 Revision 5 Figure 2-8. Model M13-2, Shown With BFR-20 Cylinder Remote Mechanical Pull Station The Model RPS-M Remote Mechanical Pull Station provides remote mechanical actuation of the Systems Releasing Module. It is connected to the Systems Releasing Module with: 1/16 (0.16 cm) stainless steel cable enclosed in 112" (1.3 cm) EMT conduit with a corner pulley at each change of direction. Buckeye Shielded Cable which does not require a corner pulley at each change of direction or conduit. A combination of both. A remote pull station is required at the point of egress from the hazard area being protected. See Figure 2-9. Figure 2-9. Model RPS-M, Remote Mechanical Pull Station Mechanical Gas Shutoff Valves A gas shutoff valve is required for all systems protecting gas fueled appliances. A mechanical means of stopping gas flow is provided by the Models BFGV-75 /100 1125 I 150 I 200 I 250 I 300 Gas Shutoff Valves. It is connected to the Systems Releasing Module with: 1/16" (0.16 cm) stainless steel cable enclosed in 1/2" (1.3 cm) EMT conduit with a corner pulley at each change of direction. Buckeye Shielded Cable which does not require a corner pulley at each change of direction or conduit. A combination of both. The valves are rated for natural or LP gas (see Figure 2- 10) and are available in the following sizes: Model Number Valve Size In (cm) Maximum Operating Pressure BFGV-75 %(1.9) 5 psi (.4 bar) BFGV-100 1(2.5) 5 psi (.4 bar) BFGV-125 1 1/4 (3.2) 5 psi (.4 bar) BFGV-150 1 1/2 (3.8) 5 psi (.4 bar) BFGV-200 2(5.1) 5 psi (.4 bar) BFGV-250 21/2 (6.4) 5 psi (.4 bar) BFGV-300 3(7.6) 5 psi (.4 bar) Note: Gas valve size must be no smaller than the size of the gas line it is connected to. 00 I o o _ A 00 Figure 2-10. Model BFGV-XXX, Mechanical Gas Valve CD IN CASE OF CR) FIRE PULL HANDLE HARD FrES12 CYSTEM CD jV RPS-M CD ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 1/16' 10.16 cm) STAINLESS DETECTION CABLE I lB LB Fusible Link Bracket Kit The Model FLB-1 Fusible Link Bracket kit (see Figure 2- II) includes the following: Standard high profile 10' (25 cm) fusible link bracket. Two (2)1/2" (1.3 cm) EMT connectors. Two (2) cable crimps. Two (2) S' hooks. Note: Fusible links must be ordered separately. FUSIBLE LINK BRACKET, 112' (1.3 cm) EMT CONNECTOR LE CRIMP Figure 2-11. Model FLB-1, 10" (25 cm) Fusible Link Bracket Assembly Fusible Link Holder The Model FLH Fusible Link Holder is designed to allow for the use of a continuous fusible link line, thus eliminating the need to cut and crimp each individual fusible link. They can be used either with or without fusible link brackets. They are available in packages of 25 (Model FLH-25). See Figure 2-12. ruww. L,rin STYLE) Figure 2-12. Model FLH, Fusible Link Holder Fusible Links The Kitchen Mister System uses Globe ML Fusible Links for automatic system activation. See Figure 2-13. Fusible links are designed to separate at specific temperatures, releasing tension from the fusible link Chapter 2 — Components Page 2 - 5 Revision 5 detection line and causing system actuation. Correct fusible link selection is an essential element in the design of any restaurant fire suppression system. After performing a temperature study to determine the maximum ambient temperature at the fusible link location, the correct fusible link should be selected from the following chart: Fusible Link Model Number Max. Ambient Temperature FL-280 225° F. (107° C.) FL-360 300° F. (149° C.) FL-450 375° F. (1910 C.) FL-500 430° F. (2210 C.) Figure 2-13. Globe ML Fusible Link Buckeye Shielded Cable As an alternative to using conduit and corner pulleys to connect the fusible link system, gas valve, and/or remote pull station to the Systems Releasing Module, the Kitchen Mister System utilizes Buckeye Shielded Cable to perform this function. Buckeye Shielded Cable is 1/16" (0.16 cm) stainless steel cable encased in a protective, flexible conduit. See Figure 2-14. Buckeye Shielded Cable requires no conduit or corner pulleys, as the name implies, provided it is installed in accordance with the guidelines set forth in this manual. Model BFR-SC-100 comes with 105 feet (32 m) of flexible conduit with 210 feet (64 m) of 1/16" (0.16 cm) stainless steel cable inside it. BUCKEYE SHIELDED CABLE Ill S (0.10 cm) STAINLESS STEEL CABLE Figure 2-14. Model BFR-SC-100, Buckeye Shielded Cable BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 3 - System Design Page 3-6 Revision 5 Four Burner Rancie with a Back-shelf - HIGH Proximity Nozzle: N-21-P (2 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximum (measured burner edge to burner edge) Nozzle Ht: 30' (76 cm)-40" (102 cm) Placement: 6" (15 cm) outside the front edge of the burners within 9" (22.6 cm) from the centerline. Aim point: 6" (15 cm) from the back edge of the burner on the centerline of the appliance. Shelf Height: Minimum of 16" (41 cm) from the top of the appliance. Wok Protection Nozzle: N-1HP(1 Flow Point) Coverage: 12" (30.5 cm) Mm. x 30" (76 cm) Max. Nozzle Ht: 30" (76 cm) - 48" (122 cm) (measured from bottom) Placement: Anywhere over the surface of the appliance. Aim Point: Center of bottom of appliance. MAXIMUM HEIGHT NOZZLEAIM 48" (122 cm) CENTER OF WOK 80 NOZZLE PLACEMENT AREA Shelf Width: A maximum of 11(28cm). The Model N-21LP nozzle is a two (2) flow point nozzle that can protect a range cooking area of 24" (61 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 40" (102 cm) above the cooking surface 6" (15 cm) from the front edge of the burners and within 9" (22.5 cm) of the centerline of the appliance. The nozzle must be aimed 6" (15 cm) from the back edge of the burner on the centerline of the appliance. The backshelf shall not be less then 16" (41 cm) from the top of the appliance and extend more then 11" (28 cm) over the back edge of the burners. See Figure 3-14a. MAXIMUM WOK DIAMETER: 30 (76 cm) MINIMUM WOK DIAMETER: 12' (30.5 cm) 7tIVIUM FftI(iHT (76 cm) SHELF WIDTH: NOT 10 EXCEED 11 (28 cm) MAX.HEIGHT: 40 (102cm) NOZZLE PLACEMENT AREA MIN, HEIGHT 30 (76 cm) AIM: V (15 cm) FROM BACK EDGE ON CENTERLINE NIMLEcI SHELF EIGHT 16(41 cm) Figure 3-14b. Wok Protection Model N-IHP Nozzle The Model N-IHP nozzle is a one (1) flow point nozzle that can protect a wok with a minimum diameter of 12" (30.5 cm) up to a maximum diameter of 30" (76 cm). The nozzle must be located 30" (76 cm) to 48" (122 cm) above the bottom of the wok and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-14b. K MAX' AX L 9(22.5 cm) BURNER EDGE TO EDGE: 24(61 cm) BURNER - '6" (15 cm) BURNER EDGE TO BURNER EDGE: 24(61 cm) Figure 3-14a. 24" (61 cm) x 24" (61cm) Range with Back-shelf Model N-21-P Nozzle ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 Chapter 3 - System Design Page 3 - 7 Revision 5 Tiltina Brazina Skillet Protection Nozzle: N-2HP (2 Flow Point) Coverage: 20.25" (51 cm) x 24" (61 cm) per nozzle Nozzle Ht: 24" (61 cm)-45" (114 cm) Placement: Anywhere over the surface of the appliance cooking area. Aim Point: Center of the protected zone. The Model N-2HP nozzle is a two (2) flow point nozzle that can protect a tilting brazing pan I skillet with a maximum cooking area of 20.25" (51 cm) wide by 24" (61 cm) deep per nozzle. The nozzle must be located 24" (61 cm) to 45" (114 cm) above the cooking surface and located anywhere over the appliance cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-16. MAXIMUM HEIGHT 45" (114 cm) COVER MUST j ..'V NOZZLE NOT INTEFERE PLACEMENT WITH NOZZLE \ j' ./ i AREA DISCHARGE MINIMUM HEIGHT 24(61 cml Figure 3-16. Tilting Skillet I Brazing Pan Model N-2HP Nozzle GRIDDLE PROTECTION Deep Fat Fryer Protection Nozzle: N-2HP (2 Flow Point) Coverage: 20.25' (51 cm) x 24" (61 cm) Nozzle Ht: 24" (61 cm)-45" (114 cm) Placement: Anywhere over the surface of the appliance cooking area. Aim point: Center of appliance. The Model N-2HP nozzle is a two (2) flow point nozzle that can protect a deep fat fryer with a maximum cooking area of 20.25" (51 cm) wide by 24" (61 cm) deep. The nozzle must be located 24" (51 cm) to 45" (114 cm) above the cooking surface and located anywhere over the appliance cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-15. NOZZLE TO BE LOCATED WITHIN THEPERIIETER OF ThE KSZARD MAXIMUM HEIGHT 45' (114 cm) NOZZLE PLACEMENT AREA MINIMUM HEIGHT 24" (61 cm) NOZZLE AIMED CENTER OF HAZARD AREA 1 MAXIMUM WIDTH: 24" (61 cm) MAXIMUM LENGTH: 20.25(51 Standard Griddle: 42"(107 cm) x 30" (76 cm Figure 3-15. 20.25" (cm) x 24" (cm) Deep Fat Fryer Model N-2HP Nozzle Fryers Reguirini Multiple Nozzles Fryers that exceed the coverage of a single nozzle can be protected with multiple nozzles. The fryer must be divided into equal sized modules, so that each module does not exceed the maximum coverage allowed for a single nozzle. CAUTION The maximum size fryer that can be modularized is 864 square inches (5,574 sq. cm). BPN: BFR-TM Nozzle: N-i LP (1 Flow Point) Coverage: 42" (107 cm) x 30" (76 cm) Maximum Nozzle Ht: 24" (61 cm) —48" (122 cm) Placement: Directly over the edge of the cooking area. Aim Point: 6" (15 cm) from center of appliance in-line with the nozzle. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect a griddle with a maximum cooking area of 42" (107 cm) wide by 30" (76 cm) deep. The nozzle must be located 24" (61 cm) to 48" (122 cm) above the cooking surface and positioned directly above the edge of the cooking area. The nozzle must be aimed 6" (15 cm) from the center of the cooking area in-line with the nozzle. See Figure 3-17. ULEX 6885 ULC-EX 6885 January 1, 2013 Chapter 3 — System Design Page 3 - 8 Revision 5 NOZZLE TO BE LOCATED I ON THE PERIMETER OF The Model N-ILP nozzle is a one (1) flow point nozzle MAXIMUM HEIGHT I THEHAZARD 48(122cm) that can protect a griddle with a maximum cooking area of 48" (122 cm) wide by 30" (76 cm) deep. The nozzle must be located 30" (76 cm) to 43" (109 cm) above the NOZZLE - PLACEMENT - - cooking surface, on the centerline of the appliance and AREA -- 6" (15 cm) off the either short edge. The nozzle must be MINIMUM HEIGHT aimed 3" (7.6 cm) from the center of the cooking area 24(61 cm)in-line with the nozzle. See Figure 3-18. Extra Large Griddle — 60" (152 cm) x 30" (76 cm) NC ZZLEAlMEONI16n,I FROM CENTER OFHAZAROAREA Nozzle: N-2LP (2 Flow Point) INLINE MTH NOZZLE - - MAXIMUM 15cm) > LENGTH: Coverage: 60" (152 cm)x 30" (76 cm) Maximum 42" (107 cm) MAXIMUM WIDTH: 30' (76 cm) Nozzle Ht: 24" (61 cm) —48" (122 cm) Figure 3-17. Placement: Directly over the edge of the cooking area. Standard Griddle: 42" (107 cm) x 30" (76 cm) Aim Point: 8" (20 cm) from center of appliance in-line Model N-ILP Nozzle with the nozzle. Large Griddle - 4811 022 cm) x 30" (76 cm) Nozzle: N-1LP(1 Flow Point) Coverage: 48" (122 cm) x 30" (76 cm) Maximum Nozzle Ht: 30" (76 cm)-43" (109 cm) Placement: On the centerline of the appliance, 6" (15 cm) off the short edge. Aim Point: 3" (7.6 cm) from center of appliance in-line with the nozzle. The Model N-2LP nozzle is a two (2) flow point nozzle that can protect a griddle with a maximum cooking area of 60" (152 cm) wide by 30" (76 cm) deep. The nozzle must be located 24" (61 cm) to 48" (122 cm) above the cooking surface and positioned directly above the edge of the cooking area. The nozzle must be aimed 8" (20 cm) from the center of the cooking area in-line with the nozzle. See Figure 3-19. NOZZLE TO BE LOCATED ON MAXIMUM HEIGHT THE PERIMETER OF THE 48(122cm) HAZARD NOZZLE PLACEMENT I MAXIMUM HEIGHT AREA MINIMUM HEIGHT 24 (61 cm) NOZZLE I A4 (109 cm) I PLACEMENT I AREA MINIMUM HEIGHT 30' (76 cm) MAXIMUM (15cm) LENGTH: 48" (122 MAXIMUM WIDTH: 30" (76 cm) Figure 3-18. Large Griddle: 48" (122 cm) x 30" (76 cm) Model N-ILP Nozzle NOZZLE AIMED 8" INL"XEETh FROM CENTER OF HAZARD AREA MAXIM> MAXIMUM LENGTH: 60 (152 WIDTH: 30(76cm) Figure 3-19. Extra Large Griddle: 60" (152 cm) x 30" (76 cm) Model N-2LP Nozzle ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 0 Extra Low Proximity Griddle Nozzle: N-2W (2 Flow Point) Coverage: 42" (107 cm) x 30" (76 cm) Maximum Nozzle Ht: 2" (5 cm) - 10" (25 cm) Placement: Over any corner, at a 450 angle to the surface. Aim Point: At cooking surface, equal distance from both edges. The Model N-2W nozzle is a two (2) flow point nozzle that can protect a griddle with a maximum cooking area of 42" (107 cm) wide by 30" (76 cm) deep. The nozzle must be located 2" (5 cm) to 10" (25 cm) above any corner of the cooking surface and positioned on the edge of the cooking area of the griddle. The nozzle must be aimed at the point over the cooking surface equal distance from both edges. See Figure 3-19a. MAXIMUM HEIGHT 10(25cm) NOZZLE PLACEMENT AREA Chapter 3 - System Design Page 3 - 9 Revision 5 of 60" (152 cm) wide by 30" (76 cm) deep. The nozzle must be located 10" (61 cm) to 30" (122 cm) above the cooking surface and positioned 0" to 3" (7.6 cm) outside the short side edge of the cooking area of the griddle. This allows the nozzle to be placed anywhere over the short edge and up to 3" (7.6 cm) outside of the short edge of the appliance. The nozzle must be aimed at the point one-quarter the longest side length (1/4L) from the griddle short edge, in-line with the nozzle. See Figure 3-19b. MAXIMUM OF 3fl (7.6cm) FROM EDGE// MAXIMUM HEIGHT 30' (76 cm) NOZZLE PLACEMENT AREA 10(25cm) MAXIMUM MAXIMUM LENGTh)L(: 6')" (152cm) W 10 TN: 30 (76 cm) Z! = ' MAXIMUM LENGTH(L): 42" (107 cm) MAXIMUM >_ WIDTH: 30 (76 cm) Figure 3-19b. 60" (152 cm) x 30" (76 cm) Griddle Model N-2W Nozzle CHARBROILER PROTECTION Figure 3-19a. 42" (107 cm) x 30" (76 cm) Griddle Model N-2W Nozzle Low Proximity Griddle Nozzle: N-2W (2 Flow Point) Coverage: 60" (152 cm) x 30" (76 cm) Maximum Nozzle Ht: 10" (25 cm) - 30" (76 cm) Placement: From 0" to 3(7.6 cm) outside the short side edge of the cooking area, Aim Point: One-quarter the length (114L) of the longest side, in-line with the nozzle. The Model N.2W nozzle is a two (2) flow point nozzle that can protect a griddle with a maximum cooking area Radiant Charbroiler Nozzle: N-1 HP (1 Flow Point) Coverage: 36" (91 cm) x 24" (61 cm) Maximum Nozzle Ht: 30" (75 cm) —48" (122 cm) Placement: Anywhere over the surface of the appliance. Aim Point: Center of appliance. The Model N-IHP nozzle is a one (1) flow point nozzle that can protect a radiant charbroiler with a cooking area of 36" (91 cm) wide by 24" (61 cm) deep. The nozzle must be located 30" (76 cm) to 48" (122 cm) above the cooking surface and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-20. BPN: BFR-TM ULEX 6885 ULC-EX 6885 January 1, 2013 /NOZZLE TO BE LOCATED WITHIN THE PERIMETER OF THE HAZARD Chapter 3 - System Design Page 3 - 10 Revision 5 NOZZLE TO BE LOCATED WTHIN MAXIMUM HGGHT THE PERIMETER OF 48 (122 em) AZARD MAXIMUM HEIGHT 40" (101 cm) NOZZLE PLACEMENT NOZZLE AREA PLACEMENT - AREA MINIMUM HEIGHT 30 (76 cm) MINIMUM HEIGHT 24" (61 cm) MAXIMUM WIDTH: 24" (61 ED CENTER OF HAZARD AR CENTER OF HAZARD AREA LENGTH: 36)91 cm) V IMDTh: 24 (El cm) Figure 3-20. Radiant Charbroiler Model N-IHP Nozzle Lava Rock Charbroiler Protection Nozzle: N-2HP (2 Flow Point) Coverage: 24" (61 cm) x 24" (61 cm) Maximum Nozzle Ht: 24" (61 cm)-40" (102 cm) Placement: Anywhere ovethe surface of the appliance. Aim Point: Center of appliance. The Model N-2HP nozzle is a two (2) flow point nozzle that can protect a lava rock charbroiler with a cooking area of 24" (61 cm) wide by 24" (61 cm) deep. The nozzle must be located 24" (61 cm) to 40" (102 cm) above the cooking surface and positioned anywhere over the cooking area. The nozzle must be aimed at the center of the cooking area. See Figure 3-21. LENGTH: 24" (61 ca Figure 3-21. Lava Rock Charbroiler Model N-2HP Nozzle Upright Broiler Protection Nozzle: N-1 LP (1 Flow Point) Coverage: 36" (91 cm) x 24" (61 cm) Maximum Nozzle Ht: Upper corner of broiling chamber. Placement: Positioned in the corner of the front opening of the appliance. Aim Point: Center of cooking grate. The Model N-ILP nozzle is a one (1) flow point nozzle that can protect an upright broiler (salamander broiler) with a cooking area of 36" (91 cm) wide by 24" (61 cm) deep. The nozzle must be located in the top front corner of the broiler and aimed at the center of the cooking grate. See Figure 3-22. ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 Chapter 3 - System Design Page 3 - 12 Revision 5 COVERAGE SUMMARY TABLE '0 COVERAGE COLOR FLOW NOZZLE HT. PLACEMENT AIMING APPLICATION NOZZLE PAGE Inches (cm) BAND POINT Inches (cm) Inches (cm) Inches (cm) DUCT, RECTANGLE UP 1050(127) PER.; MAX SIDE OF 16-3/4 (43) N1LP RED 1 1-6 (2.5-15) INTO DUCT OPENING CENTERED IN DUCT CENTER OF DUCT 3-1 DUCT, SQUARE UP TO 50 (127) PER.; MAX N-ILP RED 1 1-6 (2.5-15) INTO CENTERED IN DUCT CENTER OF DUCT 3-1 SIDE OF 12-1(2(32) DUCT OPENING DUCT, ROUND UP 1050(127) CIRCUM N-ILP RED 1 1-6 (2.5.15) INTO CENTERED IN DUCT CENTER OF DUCT 3-1 [16 (41) DIA.] DUCT OPENING DUCT, RECTANGLE UP TO 150 (381) PER.; N-2W WHITE 2 0-6 (0.15) INTO CENTERED IN DUCT CENTER OF DUCT 3.1 MAX. SIDE OF 50 (12 DUCT OPENING DUCT, SQUARE UP 10150(381) PER.; N-2W WHITE 2 0-6 (0-15) INTO CENTERED IN DUCT CENTER OF DUCT 3-1 MAX. SIDE OF 37-1/2(95) DUCT OPENING DUCT, ROUND UP TO 150 (381) CIRCUM N-2W WHITE 2 0-6 (0-15) INTO CENTERED IN DUCT CENTER OF DUCT 3-1 [47-1(2(121) DIA.] DUCT OPENING PLENUM, SINGLE 12 FT (3.7 rn) IN LENGTH; N-1HP BLUE 1 1/3 H FROM TOP; 2(5) IN FROM 0-6 (0-15) FROM END OPPOSITE END OF 3-3 BANK 4 FT (1.2 m) IN WIDTH FILTER BOTTOM PLENUM PLENUM, "V' BANK 12 FT (3.7 m) IN LENGTH; N-IHP BLUE 1 1/3 H FROM TOP; 0.6 (0.15) FROM END OPPOSITE END OF 3-3 4FT(i.2m)INWIDTH 1/2W PLENUM RANGE, TWO 3(7.6) FROM FRONT OR 6(15) FROM BURNER 12(30.5) X 24 (61) N-1LP RED 1 • 16 (41) -30 (76) BACK EDGE ON C'LINE OPPOSITE EDGE ON 3-3 (Back-shelf) * C'LINE RANGE, FOUR 24 (61)X 24 (61) N-1LP RED 1 30 (76) -40 (102) WITHIN 3(7.6) OF CENTER OF 3-4 BURNER CENTER APPLIANCE RANGE, FOUR BURNER. LOW PROXIMITY 24 (61)X 24 (61) N-2W WHITE 2 16 (41) -30(76) * CENTER OF APPLIANCE CENTER OF APPLIANCE 3-4 (Back.shelf)* RANGE, SIX BURNER 36 (91) X 24 (61) N-21L P YELLOW 2 35(89) .43(109) CENTER OF APPLIANCE CENTER OF 3-4 APPLIANCE RANGE/GRIDDLE 30 (76)X 24 (61) N-1LP RED 1 30(76)- 40 (102) WITHIN 3(7.6) OF CENTER OF 3-5 COMBINATION CENTER APPLIANCE RANGE, FOUR BURNER w/B SHELF - 24 (61)X 24 (61) N-21L YELLOW 2 30(76) -40(102) 6(15) OFF FRONT 3-6P 6(15) from BACK HIGH PROXIMITY EDGE EDGE WOK 12 (30.5) TO 30 (76) DIA. N-1 HP BLUE 1 30 (76)- 48 (122) ANYWHERE OVER HAZARD AREA BOTTOM CENTER 3-6 DEEP FAT FRYER, 20.25(51) X 24 (61) N-2HP GREEN 2 24 (61)- 45 (114) ANYWHERE OVER CENTER OF 3-7 SINGLE VAT HAZARD AREA APPLIANCE TILTING SKILLET, 20.25(51) X24 (61) N-2HP GREEN 2 24(61)- 45 (114) ANYWHERE OVER CENTER OF 3-7 BRAISING PAN HAZARD AREA APPLIANCE GRIDDLE, STANDARD 42 (107) X 3 (76) N-1LP RED 1 24(61)- 48 (122) DIRECTLY OVER EDGE OF HAZARD AREA 6(15) FROM CENTER, IN-LINE 3-7 WITH NOZZLE 6(15) OUTSIDE OF 3(7.6) FROM GRIDDLE, LARGE 48 (122) X30 (76) N-1 LP RED 1 30(76)- 43 (109) SHORTER EDGE OF CENTER, IN-LINE 3-8 HAZARD AREA ON WITH NOZZLE C'LINE GRIDDLE, EXTRA 60 (152) X30 (76) N-2LP YELLOW 2 24(61)- 48 (122) DIRECTLY OVER EDGE 8(20) FROM CENTER, IN-LINE 3-8 LARGE OF HAZARD AREA WITH NOZZLE GRIDDLE, OVER ANY CORNER AT AT COOKING STANDARD, EXTRA 42 (107) X 30 (76) N-2W WHITE 2 2 (5) -10 (25) A 450 ANGLE TO SURFACE, EQUAL 3-9 LOW PROXIMITY COOKING SURFACE DISTANCE FROM EDGES GRIDDLE, LOW PROXIMITY 60(152) X30 (78) N-2W WHITE 2 10(25) —30 (76) 0 to 3(7.6cm) outade 1/4 Length of the longest side, in-line 3-9 the short side edge with _the _nozzle CHARBROILER, 36 (91) X 24 (61) N-1HP BLUE 1 30(76)-48(122) ANYWHERE OVER CENTER OF 3-9 RADIANT HAZARD AREA APPLIANCE CHARBROILER, LAVA 24 (61)X 24(61) N-2HP GREEN 2 24(61)- 40(102) ANYWHERE OVER CENTER OF 3-10 ROCK HAZARD AREA APPLIANCE CHARBROILER, UPPER CORNER FRONT CORNER OF CENTER OF UPRIGHT 36 (91) X 24 (61) N-1 LP RED I OF BROILING OPENING TO BROILER COOKING GRATE 3-10 (SALAMANDER) CHAMBER CHAMBER * Coverages can be used when a range with a back-shelf or other type of obstruction, as long as the discharge pattern is not affected. ** Cover must not interfere with nozzle discharge. For the High Proximity Back-shelf coverage the shelf shall not exceed more then 11(28 cm) over the back edge of the burners and be a minimum of 16" (41 cm) from the top of the appliance. ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 cioz 'i kienu 9999 X3-31fl 9989 X1fl VLLth9 :Nd seizzou () oml ue9dv49q soqe o jeqwnu eqj io wess jad peoje soqe jejol aqj PJMO4 junoo ION oa Bulwle io ezzou aqj le pesn so;depe 18AIMS w (s)MoqI e6uei Jo Je,cJ4 deep OM e 6u1io94oJd U8M Aidde A1N0 suaweiinbai 6uidid wnwiuiJ :e;oj s;ueweJunbGj bU!cl!d WflWiUflJ 8 1W 009 SI OèH8 JO 9I -Id8 944 UO peMOe Budd (ao ww vLI) 81€ 40 ewnIOA ie;oi 'Jeewe!p Jallews 01 ja6je WOJ SUflJ sieMe 6uidid o eizzou eqj qoeei Aqqj se eseejoep 01 e.ie sezis pue JepuiiAo eqj o sesojo eq Isnw adid Je4ewe1p Ise6jej eq wesAs ewes 9q4 Ui pesn si l5uidid pazis juejagp ueuJ\\ L 4U!Od e6ieqosip Isel eqj Ised spuexe 48q4 6uidid io jnOAel 6U!d!d aqj U! juiod MOI e iaqie 'se qons 'elElnwnooe o p!nbil MOB PiflOM 1eqj adid o uoipes e se peuiep si dei,, '' :e;oj wesAs 6U!did 9q4 ui paoe eie sde ON 9 (w 90) 1991 Z si eull Aiddns eqj eoqe ejzzou Aue 40 es!i IeOIi.19A wnwixew eq w919,cs 6uidid aqj ut uiod Isamol io lseqBiq eqj pue 1,911no uej .io ezzou seqiq eqj pue 1911no )jU4 ueeeq eoueJejip u014ene19 wnwixew eqj ieqe Si 5114 '(w c) 1994 01. Si eU!j iddns eqj 4o asii I3I1J9A WnWIXCW eqj '(g) 8A4 S! S8IZZOU o Aue uaaeq soqe jo jaqwnu wnwixew eq c wnwixew sMoqe 9 0I9 1.10 1.-8dS wnwixew soqe o :g-g 009Z .009z 0z 0-8d9 009 009 91. S1.-d8 000Z 009Z 01. 01.-d 0001. 0091. 9 9-I9 ('w) seizzoN (iw) Su!oâ W oAn Au azisewnion UM19 i°!t adid •xj M01J xej .I9PU!ilt3 adid 'LN ZIS HMNIIIAO t13d ONidid ViflVgIXWJ (lw oi. = (wflw1.) wiw 9L€ x (w 1.9) o] ewnion adid 40 -w OGL ol lenbe si adid (ao ww 1.LI.) 8/€ JO (w i..9) 1991 o eidwx (w11w961.) '14/lW 869 adid (co ww ) 'U! CII. (wflw€) 'wiw 9L€ adid (00 ww VL1.) 'U! 8/C 4004 Jed eLunOf, saziSedid alcIumoliv 11VHO 3010A ONidid :eie wesAs ed peoje soqe jo Jeqi.unu wnwixew eq ,(CIO ww 1. .io ww vL1.) g,'ç Jeqie eq Isnw 6uidid IIV s;ueweJInbeJ bu!clld ieeueo suiod MO (€) 99jqj jo wnwuiw e oeq iieqs wesAs v '(6 89) qi 09 1, peej eq ieqs s6Uq4! 'adid eels sseiu!es .io 'peed ewoqo 'peq o enpeqo eq lleqs ed!d 'JelieSu! et.fl iq peqsuJn4 eq Isnw s6uiij pue adid :eON '6uidid euil Aiddns pue seqoueiq ueeeq uo!ou!s!p e eew ou op pue 6u!d!d we4sAs jejol uo peseq ae sJalewejed 6uidid IIV 'pesn adid aqj jo Jeeweip aq 40 ssepie6ei 'awnion adid leuialui jejol uo peseq S! JaPU!io 4Ua6e azis qoee JO; q;6ual adid wnw!u!w pue wnwixew eqj S9Z15 iepuiiico Ile .io •1W 099 u9qj ssei eq jou lleqs ewnion adid wescs jejol eqj lw 09€ uaql ssei eq jou lleqs )JOM io 'eue 'jE)Ajl e l5uiloajoid eizzou ;sesoo eqj ejojeq ewnion 6uidid WflWUJ!W eq 0(9) enij eq lleqs )jOM io e6uei 'jeicjj e 6uioeoid eizzou sasoio eqj eoeq soqa o ieqwriu wnwiu!IAJ 9 UOSAO u6!sea wasA - C iejdeq 6uisil in eqj japun peoe OR suoie!wij GS9qj 01 suoieuen ON 'eZIS iepuio qoee jol peqsIqe4se ueeq icpeejie eneq seaweed Buidid wnw!u!w pue wnwixew 'adA pejeeu!6ue-ejd eqj 40 Si we45,cs eqj asneoe 'wesi9 uoissejddng ej!d iespij uaqopj 4uewd!nb3 eii eicaone eq jol Niomlau 6uidid eqj u6isep 01 Ajesseoeu ee 1eqj suoijej!wil §uidid pe!eep suIeuoo uoqoes siq 1. SNOIIVJJINI1 0N1d1d Chapter 3 - System Design Page 3 - 14 Revision 5 DETECTOR PLACEMENT Detectors (fusible links) are required to be placed in the air stream of each appliance (one detector per appliance) and in the opening of the exhaust duct(s) of protected ventilation hoods. Detectors shall be located in the plenum area of the ventilation hood behind the filters, which provide protection for the detection system. Exhaust Duct Detector Placement Each exhaust duct must have at least one (1) detector installed. The detector is to be centered in the duct entrance and no more than 12" (30.5 cm) into ductwork. Cooking Appliance Detector Placement Each cooking appliance with a continuous cooking surface area of less than 48" (122 cm) x 48" (122 cm) must be protected by one (1) detector. The detector is to be located over the surface of the appliance and in its air stream when the ventilation system is turned on. Cooking appliances with continuous cooking surfaces larger than 48' (122 cm) x 48" (122 cm) must be protected by multiple detectors, using one detector for every 48" (122 cm) x 48" (122 cm) of continuous cooking area. Exception: If a cooking appliance or appliances are located under a duct opening where a detector has been mounted, it is not necessary to utilize an additional detector as long the duct detector is not more than 12" (30.5 cm) into the duct opening. See Figure 3-26. APPLIANCE APPLIANCE APPLIANCE APPLIANCE COVERED COVERED COVERED COVERED BY BY BY BY DETECTOR DETECTOR DETECTOR DETECTOR A B B C Figure 3-26. Proper Detector Placement Appliances and Duct ULEX 6885 ULC-EX 6885 BPN: BFR-TM January 1, 2013 Buckeye KITCHEN MISTER Coverage Summary Sheet This summary sheet is provided as a quick reference, a complete understanding of the technical manual (BFR-TM) is required. The most current Buckeye Kitchen Mister Restaurant Cooking Area Fire Suppression System Technical Manual (Part Number: BFR-TM) supersedes this reference sheet. It Is essential that this reference sheet be compared with the current technical manual before using. Dimensions given in inches (cm) unless otherwise noted. DUCT, SMALL [50" (127) MAXIMUM PERIMETER] DUCT, LARGE 1150" (381) MAXIMUM PERIMETER] NOZZLE: N-1LP NOZZLE: N-2W FLOW PTS.: 1 FLOW PTS,: 2 COLOR BAND: RED COLOR BAND: WHITE DUCT DUCT NOZZLE TI NOZZLE TIP LIP 8(1 5) " NOZZLE NOZZLE 112 W T IN NOZZLE ~TIP NOZZLE 112 w IN HOOD/PLENUM TIP L L LONGEST SIDE: 16-3/4" (43) ____________ TIP LONGEST SIDE: 50' (127) HOOD/PLENUM PLENUM, SINGLE & 4 F —i---- r-113H "V" BANK ,.-"1.2M) 112W NOZZLE: FLOW PTS.: 1 COLOR BAND This Section mA, V BANK Intentionally 12 FT 1/3H________ H 12'(54 Blank 12 7M rs MAX. SINGLE BANK RANGE, TWO BURNER CAN BE USED WITH RANGE, FOUR BURNER, RANGE, FOUR BURNER, (LOW PROXIMITY) BACK-SHELF. SHELF MUST NOT (HIGH PROXIMITY) (LOW PROXIMITY) NOZZLE: N-ILP INTEFERE WiTh NOZZLE DISCHARGE NOZZLE: N-1LP MAX. HEIGHT PLACEMENT: NOZZLE: N-2W OF "GE FLOW PTS.: I FLACEMENT: FLOW PTS.: I FLOW P15.: 2 — MAX. HEIGHT: 50" (78) COLOR BAND: THIN 3' (1.6) COLOR BAND: COLOR BAND: WHITE RED AIM: 6'(lS)FROM RED —MIN. HEIGHT: 18" (41) MAX. HEIGHT: OPPOSITE EDGE (78) AIM: CENTER 30" (76) ON LONG AIM CANBEUSEOWWI OF RANGE MIN IEIGIcr• CENTER LINE CENTER OF BAb1-SHELF. SHELF MUST NOT INTEFERE , jIGHT:0FCEjR RANGE NTH NO 6" (15) DISCHARG MAX HA )D MAX WIDTH: 24 (61) B ER TO URN io BURNER BURNER BURNER LENGTH: 1? (308) : • BURNER LENGTH: BURNER WIDTH: LENGTH 24 (61) 0 TO BURNER PLACEMENT; 24" (61) 24"(61) 0TH: 24' FROM FRONT OR BACK EDGE, ON ______________ LONG CENTER LINE _____________________________________________________ (81) RANGEJGRIDDLECOMBINATION RANGE, SIX BURNER PLACEMENT: SHELFWER14NOIIO RANGE, WITH BACKSHELF, CENTER OF RANGE NOZZLE: N-I LP HEIGHT: NOZZLE: N-2LP FLOW PTS.: 43(109) FLOW COLOR BAND' MAX 40' I102I— FLOW PIS.: 2 COLOR BAND : - . : MIN HEIGHT RED HEIGHT:LACE ME I I . COLOR BAND: YELLOW 35 (89) 43" (102) WITHIN 3' (7.6) MIN. HEIGHT.—YELLOW MIN. HEIGHT: OF CENTER IA CENTER 30(76) AIM: CENTER OF MINIMUM OF RANGE NGE-GRIDDLE RECRE](HIGHPROMITY) AIM; 6'(15) SHELFHEIGHT NOZZLE :N-2LP _jHEj , FROM BACK 10' (411. EDGE ON MAX12* CENTER-LINE (30.5) (IS) BURNER TO 0 <Z URNEREDGE TO BURNER BURNER 0 BURNERTO MAX. LEN TN: MAX WIDTH: 24 (81) BURNER EDGE 0'I2Z5) EDGE; 24 (81) CAN BE USED LENGTH: 38" (91) BURNER 30' (76) TO BURNER 0' WITHOUTA WIDTH: 24" (61) EDGE: 24" (611 (15) BACK-SHELF ___________________________ DEEP FAT FRYER, LG. SINGLE VAT TILTING SKILLET _ NOZZLE: N-2HP PLACEMENT: NOZZLE: N-21HP HAZARD COVERAGE AREA: 20.25"(51)x24"(61) FLOW PTS.: 2 WITHIN THE FLOW PTS.: 2 COLOR BAND: '-PERIMETEROF COLOR BAND: GREEN THE HAZARD GREEN COVER MUST FOR NOT INTEFERE & MAX. WITH NOZZLE ;MIN. This Section MAX. HEIGHT 45"(114) / DISCHARGE MIN. HEIGHT: 24'(61) NOZZLE HEIGHTS, / POSITION AND AIM Intentionally AIM: CENTER OF HAZARD / POINT REFER TO / FRYER NOZZLE Blank AREA PARAMETERS Note: Total hazard ____ area can not MAX. WIDTH: exceed 864 In' MAX LEN T 24'(61) (5,574 2), 20.28" (51 BPN: P1S10374 REV. 5; DATE: JANUARY 1, 2013 LENGTH: 36'(91) WIDTH: 24'(61) AIM: CENTER OF HAZARD AREA MAX LENGTH: 24' (61) 24' (61) AM:ATcENTENOF ' NOR 801mM MAX - HEIGHT: 48' (122) MIN. -HEIGHT; 30' (76) PLACEMEN1 WITHIN THE PERIMETER OF THE HAZARD X.WOKDIA.:30 (.WOK DIAL: 12 WOK NOZZLE: N-1HP FLOW PTS.: I COLOR BAND: BLUE Buckeye KITCHEN MISTER Coverage Summary Sheet This summary sheet is provided as a quick reference, a complete understanding of the technical manual (BFR.TM) is required. The most current Buckeye Kitchen Mister Restaurant Cooking Area Fire Suppression System Technical Manual (Part Number: BFR-TM) supersedes this reference sheet. It Is essential that this reference sheet be compared with the current technical manual before using. Dimensions given in Inches (cm) unless otherwise noted. GRIDDLE, STANDARD [42"(107) MAX.] NOZZLE: N-ILP FLOW PTS,: I COLOR BAND: RED PLACEMENT: ON THE PERIMETER OF AIM:8'(15) MAX. HEIGHT: FROM CENTER (122) OF HAZARD AREA. INUNE -MIN. HEIGHT: WIN NOZZLE • OF THE Z A 24'(81) MAX. LEN : 42' (7) MAX, DTH: 30'(76) GRIDDLE, XLARGE [60" (152) MAX.] NOZZLE: N-2LP PLACEMENT: ON FLOW PTS,: 2 THE PERIMETER COLOR BAND: OF T HAZARD YELLOW -HEIGHT: NM: 6(35) FROM CENTER MIN. OF= AR 48. (122) HE HEIGHT: WITH NOZZLE 24'(81) MAX LEN 60'(152) AI WIDTH: ) MAMUMOF GRIDDLE, LOW 3(7A)//'.. PROXIMITY MAXIMUM MAXIMUM HEIGHT: NOZZLE: N-2W 35' (18) FLOW PIS.: 2 110551.! OLOR BAND WHITE PI.A55MENT NASHUA HEIGHT: 1E'(28) kLENGTKL) WIDTH(P4 35' (18> RADIANT CHARBROILER NOZZLE: N.1HP .N PLACEMENT: WITHIN FLOW PTS.: I ". THE PERIMEISROF COLOR BAND: THE HAZARD BLUE MAX HEIGHT -48'(122) AIM: CENTER HEIGHT OF HAZARD AREA - GRIDDLE, EXTRA I ): PROXIMITY MAXIMUM NOZZLE: N-2W HEIGHT 10'(25( FLOW PTS.: 2 I NOZZLE PLACEMENT 'SHALL 05 ABOVE COLOR BAND: I MINMUM %4 ANY 00 WHITE HEIGHT 2'ISI L'W MAXIMUM MAXIMUM L%) WIOTh('A 30' (78) LAVA ROCK CHARBROILER NOZZLE: N-2HP FLOW P18.: 2 COLOR BAND: PLACEMENT: WITHIN THE GREEN PERIMETER OF THE HAZARD MAX. HEIGHT IAN HEIGHT: FLOW PTS.:1 IL_.... COLOR BAND: RED NM CENTER OF COOKING 11 GRATE I PLACEMENT: TOP CORNER OF EN LEN, FRONT OPENING 36(91) MAX. WID '24' 81) MAXIMUM PIPING PER CYLINDER SIZE Piping Limitations: >318"(17.1 mmOD) orl/2'(21.3mmOD) Sch. 40 black pipe, Minimum Piping Requirements (Wok, Range, & DFFonly): CYLINDER MAX. FLOW MAX. PIPE VOLUME MAX. PIPE VOLBETWEEN MAX. # OF SIZE POINTS ALLOWED (ml.) ANY TWO NOZZLES (mL) ELBOWS 'PIpe sized largest to smallest only. 'No "traps' allowed. > Max. number of elbows between any (2) nozzles: 6 > Min.elbows before closest nozzle: S. > Mm. pipe volume before closest nozzle: 360 mL. BFR-5 5 1500 1000 20 BFR1O 10 2500 2000 25 'Max. vertical rise: 10 feet (3m). >Total system pipe volume: 600 mL. 2800* BFR-15 15 2500 25 > Max. vertical rise from nozzle to supply life: 2 feet (0.6 m). 'Minimum number of flow points in system: 3. BFR-20 20 2800° 2500 25 - I OtI vo'ume 01 3Iø PlPIfl9 aiowea IS ZDUU CONDUIT AND BUCKEYE SHIELDED CABLE (BSC) LIMITATIONS {_PIPE SIZE (SCH. 40) PIPE VOLUME FUNCTION MAX. CONDUIT LENGTH FT (M) MAXIMUM NUMBER OF CORNER PULLEYS MAX. LENGTH OF BSC FT (M) MAXIMUM NUMBER OF BENDS IN THE BBC (MIN. BEND RADIUS) BSC TO CONDUIT TRANSITIONS (NUMBEROF BSCI) MAXIMUM NUMBER OF FUSIBLE LINKSAND HOLDERS I WS In. (17.1 mm OD) pipe I 37.5 mL./ft. (I23mUm) [1/2 in. (21. mm OD) pipe I 59.8 mL./ft, (196mL/m) REMOTE CYLINDER ACTUATION LIMITATIONS ACTUATION CARTRIDGE PART NUMBER NUMBER OF CYLINDER(S) THAT CAN BE ACTUATED MAX. LENGTH OF 1/4' (0.6) OD COPPER TUBING MAX. LENGTH OF TUBING BETWEEN CYLINDERS FUSIBLE LINK LINE; CONDUIT & BSC 25(7.6) =8 35(10.7) 6 [9' (23)] 6 10 GAS VALVE LINE; CONDUIT & BSC 25(7.6) 8 - 35 (10.7) 6[9' (23)] 6 NA RPS-M LINE; CONDUIT & BSC 25(7.6) 35(10.7) 6[9(23)] 6 NA FUSIBLE LINK LINE; CONDUIT ONLY 150(45.7) 35 NA NA NA 20 GAS VALVE LINE; CONDUIT ONLY 150(45.7) 35 NA NA NA NA BFR-AC-S 1-3 15 FEET (4.6 m) 3 FEET (0.9 m) RPS-M LINE; CONDUIT ONLY 150(45.7) 35 NA NA NA NA FUSIBLE LINK LINE; BSC ONLY NA NA 35(10.7) 6 [9" (23)] 6 10 BFR-AC-L 1-5 25 FEET (7.6 m) 3FEET (0.9 m) GAS VALVE LINE; BSC ONLY NA NA 35(10.7) 6(9' (23)1 6 NA RPS-M LINE; BSC ONLY I NA NA 35(10.7) 6[9" (23)] 6 NA BSC CAN NOT be coiled or looped when installed. BPN: P1S10374 REV. 5 DATE: JANUARY 1, 2013 LiEyE msII b •buckeyet.cani • Internet: hflp'Jtwww.buckeyet.com/tlre September 17, 2008 Subject: Gyro Cooker Protection To: Authorized Buckeye Kitchen MisterT4 Distributors To Whom It May Concern: Underwriters Laboratories Inc.. (UL) does not currently have a testing procedure for gyro cookers, however, these appliances may require protection based on the judgment of the local authority having jurisdiction. When protection is required, gyro cookers are protected in the same manner as an upright broiler (see page 3-8 and 3-9 of the Buckeye Technical Manual, P/N 8FRTM). One model N-ILP nozzle is used to protect a gyro cooker with a maximum cooking area of 36' wide by 24" deep. For this application, the nozzle is to be located in the top corner of the appliance and aimed at the bottom center. If the appliance is equipped with doors, the nozzle must be positioned in such a manner that the doors do not interfere with the discharge of the nozzle, If you have any additional questions please do not hesitate to contact me. Sincerely, /~__ - - 0 ~Xj_ Bruce Euler Pre-engineered Systems Manager Buckeye Fire Equipment company ISO 9001 Registered M '. 0 1 ME \1 ' E-mail; bfec@buckeyef.com Website: www.buckeyetire.com June 29, 2017 Mr. James Wiseman San Diego Fire Protection Subject: Response to your inquiry regarding the applicable NFPA-96 requirements for replacement air shut-down upon fire extinguishing system activation. Dear Mr. Wiseman, The NFPA-96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, Section 8.3.2, is the binding code requirement regarding replacement air (makeup air) shut-down during system activation. The Kitchen Mister System, and any other restaurant area fire suppression system for that matter, must comply with this requirement. It states: "8.3.2 When the fire-extinguishing system activates, makeup air supplied internally to the hood shall be shut off." The term "internally", as sited in this section, is intended to specify that only makeup air that is supplied directly into the hood itself (i.e., into the catch basin of the hood) is required to be shut off. Any makeup air supplied outside of the hood itself is not required to be shut off. I hope this information helps clarify the issue. I should point out that I am on the NFPA-96 Technical Committee and have a very good working knowledge of both the current document and its history. Kind Regards, ktiAe_ William Vegso Buckeye Fire Equipment Buckeye Fire Equipment Company ISO 9001-2008 Registered of rftfies that sums., 4iaizhr !Cr 11a1i±CflaflCC X\I J)J > r rmtn±ø-xirfl urkur ifr iffri trehg ufrtzi ±a thr. urh'gt ifren frr 3Et ¶J1fri uppreftrn / L'qitipmnf 3i±r1n in±xIL prfttrm .hc,uranf Cauhing Area 3IEbucaftuxud rebit Mours J1Earn: 8 (Ierhficrthrn Vahb Until 09/08/2020 3Litn Nufuer 1r2stenf Burheve Tire 3quipmenf Qlum