Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2200 FARADAY AVE; ; FS080029; Permit
11/3/21, 12:36 PM FS080029 Permit Data City of Carlsbad Fixed Systems Permit Permit No: FS080029 Job Address: 2200 FARADAY AV Permit Type: FIXSYS Parcel No: 2121204100 Lot #: 0 Reference No.: Status: ISSUED Applied 12/17/2008 Approved: 12/17/2008 Issued: 12/17/2008 PC #: Inspector: Project Title: SIERRA WIRELESS SPECIAL CHEMICAL PLAN CHECK & INSPECTIONS Applicant: AIRGAS FIRE PROTECTION 9010 CLAIREMONT MESA BL SAN DEIGO, CA 858-495-2327 Owner: D L FARADAY L P C/O DRA ADVISORS LLC 220 E 42ND ST #27 NEW YORK NY Fees ($) Add'I Fees ($) Total ($) Balance 130 0 130 0 i/l __ FSOZW21 ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved (J.l.) 2Y0A9.AF, IJLC listed CEx1151 (.. Version 2. 1.2 c File: Data file name: C:\Program Files\lnergen Designer\CALCS\08MJJ2115F.inr with unsaved èvjSions. Job Number 08MJJ2115F for SIERRA WIRELESS Address: 2200 FARADAY AVE. CARLSBAD CA. 92008 Country: USA Aaent Storaae Conditions Storage pressure is 2175 psia at 70 degrees Fahrenheit. 439 cubic feet of INERGEN stored in each of 5 cylinders. Total agent in storage is 2195 cubic feet. Time to discharge 1976 cubic feet (90% of INERGEN) is 70.2 seconds Maximum pressure downstream of manifold orifice is 1306 psia Concentrations 95% Maximum Minimum Requested Time Cu Ft Concentration Concentration Concentration Area : Volume (sec) INERGEN at Max. Temp. at Mm. Temp. at Min Temp. SERVER ROOM 4611.6 59 2195.0 38.1% at 75°F 37.6% at 65°F 34.2% at 65°F Sea level equivalent oxygen: 13.0% at 75°F Free Vent Calculation Peak Maximum Wall Minimum Free Area Rate Strength Vent Area SERVER ROOM 4688.4 cfm 5.0 lbs./sq.ft. 179 sq. in. Pressure Drop Results Sec Sec Nominal Length Equiv Elev Tee! Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 1 2 1/2 40T 0.0 38.0 0.0 MFLD 1033 1001 484.7 2 3 11/4 80T 1.0 4.2 0.0 MFLD 1001 1003 484.7 3 4 11/4 80T 1.0 3.1 0.0 MFLD 1003 1003 969.5 4 5 11/4 80T 1.0 3.1 0.0 MFLD 1003 1001 1454.2 5 6 11/4 80T 1.0 3.1 0.0 MELD 1001 1000 1938.9 6 7 1 1/4 80 T 0.5 2.6 0.0 MELD 1000 998 2423.7 7 8 1 1/4 80 T 0.5 3.7 0.5 MFLD 998 996 2423.7 1 (Continued) V ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved (J.l.) 2Y0A9.AF, ULC listed CEx1151 : Version 2.1.2 File: Data file name: C:\Program Files\Inergen Designer\CALCS\08MJJ2115F.inr with unsaved revisions. J6b Number: 08MJJ2115F Pressure Drop Results (Continued) Sec Sec Nominal Length Eq.uiv Elev Tee! Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psia psia (cfm) 8 9 ORIFICE .438 INCHES DRILL NO. 7/16 996 440 2423.7 9 10 1 1/4 40 T 3.5 3.5 3.5 440 586 2423.7 10 11 11/4 40T 1.0 4.5 0.0 586 583 2423.7 11 12 1 401 3.0 8.2 0.0 BULL 583 579 1211.8 12 301 1 401 1.0 3.6 -1.0 579 577 1211.8 11 13 1 40T 3.0 8.2 0.0 BULL 583 579 1211.8 13 302 1 40T 1.0 3.6 -1.0 579 577 1211.8 Calculation based on 70 degree Fahrenheit pre-discharge Pipeline Temperature Pipe and Fittings Sec Sec Nominal Length Side Thru Unions! EqI Start End Pipe Size (ft) 90's Tee Tee Cp!gs (if) 1 2 1/2 40 1 0.0 0 0 0 0 Cyl Valve 38 ft 2 3 11/4 801 .1.0 1 0 0 0 3 4 11/480T 1.0 00 1 0 4 5 11/480T.1.0 0 0 1 0 5 6 11/480T 1.0 0 0 1 0 6 7 11/4 801 0.5 0 0 1 0 7 8 11/4 801 0.5 1 0 0 0 8 9 1 1/4 80 1 0 0 0 0 Man. Orifice 9 10 11/4 401 3.5 0 0 0 0 10 11 11/4 40T 1.0 1 0 0 11 12 1 40T 3.0 0 1 0 0 12 301 1 40T 1.0 1 0 0 0 11 13 1 40T 3.0 0 1 0 0 13 302 1 40T 1.0 1 0 0 0 Nozzle Performance Summary Nozzle Nominal Drill Drill Quantity (Cu ft) Area Number Pipe Size Number. :Diameter Discharged Name 301 1 40 1 7/16 0.437 1097.5 SERVER ROOM 2 (Continued) ANSUL INERGEN DESIGNER UL listed EX4510, FMRC Approved (J.l.) 2Y0A9.AF, ULC listed CEx1151 Version 2.1.2 File: Data file name: C:\Program Files\lnergen Designer\CALCS\08MJJ21 15F.inr with unsaved revisions. Job Number: 08MJJ2115F. Nozzle Performance Summary (Continued) Nozzle Nominal Drill Drill Quantity (Cu ft) Area Number Pipe Size Number Diameter Discharged Name 302 1 40 T 7/16 0.437 1097.5 SERVER ROOM Messages/Errors ANSUL 150 bar•Ii4ERGEN DESIGNER Version number 2.1.2 Calculation done on 12/10/2008 at 9:21:35 AM Pipe schedule selected for pipe sizes downstream of the manifold orifice is based on the maximum pipe pressure for Grade A-5313, A1 06B Seamless. To determine if other grades are acceptable, verify that the maximum pipe pressures for other grades are equal to or greater than the maximum anticipated downstream pressure. Calculation by Airgas West Fire Protection Dennis Buth 1340 E. Mission Blvd Pomona CA 91766 Telephone: 909-868-5000 Fax: 909-397-0562 3 End of Printout ., AIRGAS West Fire Protection 9010 CLAIREMONT MESA BLVD. SAN DIEGO, CA 92123 PHONE (858) 495-2328, FAX (858) 496-3820 SIERRA WIRELESS 2200 FARADAY AVE. CARLS BAD, CA. 92008 SUBMITTAL FOR: ANSUL, INERGEN, INERT GAS FIRE SUPPRESSION SYSTEM DESIGN BY: DENNIS BUTH (SYSTEM DESIGNER) 858495-4841 0 0 INERGEN FIRE SUPPRESSION SYSTEM ~je AN L@ Ansul Device Compatibility Document I Document 500E4 04/05/2005 Rev: J I Ill1,I,Jt FM-Approved Automatic Water Control Valves for PreAction and Deluge Sprinkler Applications (section not recognized by UL) AUTOPULSE 442R/D, AUTOPULSE IQ-301 AUTOPULSE IQ-396 AUTOPULSE IQ- 636X Solenoid Group [A] Skinner solenoid valve Model LV2LBX25, 24 VDC, 11 WATTS, 458 mA, 1/2 in. NPS, 5/8 in. orifice. Solenoid Group [B] These valves are interchangeable. ASCO solenoid valve Model T8210A107, 24 VDC, 16.8 WATTS, 700 mA, 1/2 in. NPS, 5/8 in. orifice. ASCO solenoid valve Model R8210A107, 24 VDC, 16.8 WATTS, 700 mA, 1/2 in. NPS, 5/8 in. orifice. ASCO solenoid valve Model 8210A107, 24 VDC, 16.8 WATTS, 700 mA, 1/2 in. NPS, 5/8 in. orifice. Solenoid Group [C] Star Sprinkler Corp. Solenoid P/N 5550, 24 VDC, part of Model 0 deluge valve. Solenoid Group [D] ASCO solenoid valve Model 8210G207, 24 V dc, 10.6 WATTS, 440 mA, 1/2 in. NPS, 1/2 in. orifice. Solenoid Group [E] Skinner solenoid valve Model 73218BN4UNLVNOC1 1 IC2, 24 V dc, 10 WATTS, 420 mA, 1/2 in. NPS, 5/8 in. orifice. S Solenoid Group [F] Skinner solenoid valve Model 73212BN4TNLVN0C322C2, 24 V dc, 22 WATTS, 1/2 in. NPS, 0.92 A, 250 psi (1725 kPa), 1/2 in. orifice. Solenoid Group [G] Skinner solenoid valve Model 713955N2ENJ 1 NOH 111 C2, 24 V dc, 10 WATTS, 420 mA, I r14 in. NPS, 1/16 in. orifice, 250 psi (1725 kPa) rated working pressure. Ansul CV98 Electric Activator, P/N 423684; 24V, 0.9-1.6 ohms, 0.6 Amps Ansul CV-90 Electric Activator, P/N 426876,24VDC Ansul Current Limiter Module, P/N 427354 Ansul Electric Actuator P/N 73111, 24 VDC Ansul HF Electric Actuator P/N 73327, 12 VDC Ansul Electric Actuator P/N 73097, 24 VDC Ansul Electric Activator, P/N 570537,24VDC Ansul AUTOMAN Il-C, P/N 31438, 24VDC Note: Refer to the FM approval guide for automatic water control valves that are compatible with solenoids listed above. Agent Releasing Applications Employ UL Listed and/or FM approved 24VDC solenoid for these Applications. (Refer to the appropriate panel installation manual to determine the available power output.) Ansul Device Compatibility Document Document 50054 Rev: J ECN 05-706 04/05/05 Table 7. Wheelock Notification Appliances (UL Listed) 10 Control panels with notification circuits supplied by special purpose (FWR, filtered) power must use appliances listed in this table. Use only 12VDC devices with 12 volt control panels. WHEELOCK Rated Voltage 2 FWR DC Filtered DC Sync. Module Notes: All current draws are shown in milliamperes and reflect worst case average. Nominal operating voltages shown. Refer to manufacturers installation instructions for more information. * Contact manufacturer for current draws. ** The strobe portion Wheelock 70021-24 Horn with Strobe 24VDC * * N/A Wheelock AES-DLI-LSM-24 Horn Strobe 24 VDC * * N/A Wheelock AES-DLI-WM-24-VF-R MultiTone Signals (ULC) 24VDC * * N/A Wheelock AES-EL1-LSM-24 Horn Strobe 24 VDC * * N/A Wheelock AES-ELI-WM-24-VF-R Multitone Signals 24VDC * * N/A Wheelock AH-24 Horn (ULC) 24VDC * * N/A Wheelock AH-24WP Horn (ULC) 24VDC * * N/A Wheelock AMT-24 Multitone Horn (ULC) 24VDC 48 48 N/A Wheelock AMT-2475-FR Horn Strobe (ULC) 24VDC 261 max* 267max* N/A Wheelock AMT-24-IS-VFR Multitone Horn Strobe 24VDC 348 323 N/A Wheelock AMT-24-LS-VFR Multitone Horn Strobe (ULC) 24VDC 143 138 N/A Wheelock AMT-24-LSM-VFR Multitone Horn Strobe 24VDC 188 178 N/A —Wheelock AS-1215 Audible Strobe 12 VDC 311 252 SM/DSM Wheelock AS-121575 Audible Strobe 12 VDC 429 391 SM/DSM —Wheelock AS-1230 Audible Strobe 12 VDC 413 355 SM/DSM —Wheelock AS-2415 Audible Strobe 24 VDC 140 104 SM/DSM Wheelock AS-2415C Horn/Strobe (ULC) 24VDC 167 126 SM/DSM Wheelock AS-2415W Horn/Strobe (ULC) 24VDC 95 134 SM/DSM Wheelock AS-241575 Audible Strobe 24 VDC 162 121 SM/DSM Wheelock AS-241575W Horn/Strobe 24VDC 110 147 SM/DSM Wheelock AS-2430 Audible Strobe 24 VDC 190 148 SM/DSM Wheelock AS-2430C Horn/Strobe 24VDC 220 186 SM/DSM Wheelock AS-2430W Horn/Strobe 24VDC 135 177 SM/DSM Wheelock AS-2475 Audible Strobe 24 VDC 295 299 SM/DSM Wheelock AS-2475C Horn/Strobe (ULC) E (ULC) 24VDC 432 340 SM/DSM Wheelock AS-2475W Horn/Strobe (ULC) 24VDC 211 283 SM/DSM Wheelock AS-24100C Horn/Strobe 24VDC 486 417 SM/DSM Wheelock AS-24110 Audible Strobe 24 VDC 443 333 SM/DSM Wheelock AS-24110W Horn/Strobe (ULC) 24VDC 242 326 SM/DSM Wheelock AS-24MCC Multi-Candela Audible Strobe 24 VDC 424 max* 330 max* SM/DSM** Wheelock AS-24MCW Audible Strobe Multi-Candela (ULC) 24 VDC 414 max* 280 max* SM/DSM Wheelock ASWP-2475W Horn/Strobe 24VDC 187 186 SM/DSM Wheelock CH-CF1-LS-24-CFW Chime 24 VDC 101 100 SM/DSM Wheelock CH-CF1-MS-24-CFW Chime 24 VDC 155 155 SM/DSM Wheelock CH-CFI-IS-24-CFW Chime 24 VDC 273 260 SM/DSM Wheelock CH-DF1-LS-24-VFR Chime 24 VDC 101 100 SM/DSM Wheelock CH-DF1-LSM-24-VFR Chime 24 VDC 145 120 SM/DSM Wheelock CH-DF1-MS-24-VFR Chime 24 VDC 155 155 SM/DSM Wheelock CH-DF1-IS-24-VFR Chime 24 VDC 273 260 SM/DSM Wheelock CH70-24 Chime 24VDC 22 22 SM/DSM Wheelock CH70-241 5W Chime with Strobe 24VDC 105 85 SM/DSM Wheelock CH70-241575 Chime with Strobe 24VDC 127 102 SM/DSM Wheelock CH70-2430 Chime with Strobe 24VDC 153 122 SM/DSM Wheelock CH70-2475 Chime with Strobe 24VDC 239 187 SM/DSM Wheelock CH70-24MCW-FRJW Multi-Candela Chime with Strobe 24VDC 392 max * 257 max * SM/DSM Wheelock CH90-24 Chime 24VDC 22 22 SM/DSM Wheelock CH90-24MCC-FW Multi-Candela Chime with Strobe 24VDC 422 max* 314 max SM/DSM** Wheelock CH90-2475C Chime with Strobe 24VDC 259 251 SM/DSM Wheelock CH90-24100C Chime with Strobe 24VDC 318 314 SM/DSM Wheelock DSM-12/24 Dual Synchronization Module L?C' 38/82 20/50 N/A Wheelock E70 Speaker N/A * * N/A Wheelock E70-2415W Speaker with Strobe 24VDC** 83** 6**3 SM/DSM** 12 Ansul Device Compatibility Document Document 50054 Rev:J ECN 05-706 04/05/05 Wiring Initiating Device Circuits Guidelines Initiating Device Circuits are used for wiring smoke and heat detectors to the AutoPulse Z-10. Be aware that correct operation of the AutoPulse Z-10 depends on the proper installation and placement of smoke and heat detectors. This is particularly true when installing a cross-zoned, agent release system. With a cross-zoned system, the detectors in the room must be installed so that each successive detector in the space being protected is on an alternating zone pattern. The location and spacing of detectors shall be in accordance with the requirements of Section 2-3.4 of the National Fire Alarm Code (NFPA 72). Ansul recommends 250 ft2 spacing per detector. Adhere to the following guidelines when wiring IDCs: All wiring must be from 12 AWG (max.) to 18 AWG (mm.). Conductors must test free of all grounds. All wiring is supervised and power limited. Leave 3.3K, 1/2W resistor (Part No. 430156) across all unused IDC terminals. See note jj in Figure 3-1 (two-wire). Terminate Style B Class B) circuits with a listed 3.3K, 1W (Part No. 431210) end-of-line resistor. See note 5 in Figure 3-1, Terminate Style Class A) circuits with a listed 3.3K, 1 W (Part No. 431210) end-of-line resistor. See note 6 in Figure 3-1. For Canadian applications, attach the following resistor to the ULC-listed EOL device. - Part No. 431210 3.3K, lWresistor - Part No. 431537, Steel plate EOL Device Maximum line resistance for a circuit is 50 Ohms. Maximum number of smoke/heat detectors per IDC is 30. Maximum detector standby current is 3mA. Maximum alarm current at 24 VDC (short) is 60 mA. Voltage rating - nominal 24 VDC, 0.5V peak-to-peak ripple (max.) Any combination of the detectors and bases listed below may be installed, except only one Part No. 430569 or Part No. 430702 (Canadian) may be used per circuit. The compatibility identifier is the model number found on the detector, base, and control unit. Compatible device Part Numbers are as follows: (Refer to Part No. 431424 for installation instructions.) 430559, Photoelectric Smoke (2.8 %) Detector 430695, Photoelectric Smoke (2.8 %) Detector, Canadian 430560, Combination Photoelectric/Heat Detector 430696, Combination Photoelectric/Heat Detector, Canadian 430561, Ionization Smoke Detector 430697, Ionization Smoke Detector, Canadian 430562, Photoelectric Smoke (3.5%) Detector 430565, 135' Fixed Temperature with Rate-of-Rise Electronic Heat Detector 430699, 135° Fixed Temperature with Rate-of-Rise Electronic Heat Detector, Canadian 430566, 200° Fixed Temperature with Rate-of-Rise Electronic Heat Detector 430700, 200° Fixed Temperature with Rate-of-Rise Electronic Heat Detector, Canadian Compatible Bases. (Refer to Part No. 431425 for installation instructions.) 430567, Two Wire Base (30 / Loop) 430701, Two Wire Base (30 / Loop), Canadian 430569, Two Wire Base with Aux. Alarm Relay (1 / Loop) 430702, Two Wire Base with Aux. Alarm Relay (1 / Loop), Canadian 430570, Two Wire Base with LED (Part Nos. 430563 through 430566 only) 430703, Two Wire Base with LED (Part Nos. 430563 through 430566 only), Canadian Continued on next page 3-2 Wiring Releasing Circuits Guidelines The Releasing Appliance Circuits (RACs) on the AutoPulse Z- 10 are designated on the printed circuit board as RAC and RAC2. Each RAC must connect to a Part No. 430687 coil supervision module, which in turn connects to a 12 VDC or 24 VDC solenoid (also known as an actuator). Figure 3-2 shows the wiring connections to the AutoPulse Z-10. All wiring must be 18 AWG (mm.) to 12 AWG (max.). Conductors must test free of all grounds. All wiring is supervised and power limited unless otherwise noted. Wiring between Part No. 430687 coil supervision module (Yell/Black) is not power limited. Refer to the Coil Supervision Module Wiring Instructions (Part No. 431303). Leave a 10K, 1/2 W (Part No. 431223) resistor across all unused RAC terminals. Voltage rating - nominal 24 VDC, 0.5 V peak-to-peak ripple, maximum. Total available current from main power supply is 3A. If auxiliary power is used, available signal power is reduced accordingly. Terminal designations "+" and "-" are for the alarm state. Connect 24 VDC actuator as shown, only one 24 VDC actuator per RAC. Connect 12 VDC actuator as shown; two units must be connected via a maximum of 20 feet of wiring in conduit. For specific actuator wiring instructions, refer to the manufacturer's recommendations. Only releasing devices meeting the following criteria may be used with the AUTOPULSE Z-lO: - Releasing devices specified by part number in this manual. ( - Any UL listed and/or FM-approved (as applicable) releasing device that is rated at 24VDC (2 Amp max) and has been specifically approved for use with the AUTOPULSE Z-10 by Ansul Incorporated. - Any releasing device rated at 24VDC (2 Amp max) that is a component of a UL listed or FM-approved fire suppression system, and is specifically approved for use with the AUTOPULSE Z-10 by Ansul Incorporated. Max. alarm current is 2A per circuit. See following chart for line distances. RAC2 is used as NAC3 (visual notification appliances) for the New York City Abort application. Maximum Distance from Panel to Releasing Device (Feet) Alarm Current (Amps) 18 AWG 16 AWG 14 AWG 12 AWG Line Resistance (Ohms) 0.25 434 690 1098 1747 6.2 0.50 217 345 549 874 3.1 0.75 145 230 366 582 2.07 1 109 172 275 437 1.55 1.25 87 138 220 349 1.24 1.50 72 115 183 291 1.03 1.75 62 99 157 250 0.89 2 54 86 137 218 0.77 Continued on next page 3-4 S Wiring Notification Appliance Circuits Guidelines Adhere to the following guidelines when wiring Notification Appliance Circuits. All wiring is to be 18 AWG (mm.) to 12 AWG (max.) Conductors must test free of all grounds. All wiring is supervised and power limited. Leave a 10K, 1/2 W (Part No. 431223) resistor across all unused NAC terminals. See n4 in Figure 3-8 below. Terminate Style Y (Class B) circuits with a listed 10K, 1/2 W (Part No. 431222) end-of-line resistor. See F5] in figure. For Canadian applications, attach a 10K 1/2 W resistor (Part No. 431222) to a ULC-listed End of Line Device (Part No. 431537). Terminate Style Z (Class A) circuits with a listed 10K, 1/2 W (Part No. 431222) end-of-line resistor. See in figure. Voltage rating - nominal 24 VDC, 0.5 V peak-to-peak ripple (max.) Total available current from main power supply is 3 A. If auxiliary power is used, available signal power is reduced accordingly. Terminal designations "+" and "-" are for the alarm state. Compatible appliances listed below. Maximum 70 appliances per circuit. Maximum alarm current is 2A per circuit. See chart below for line distance. - Part No. 429694 (sounder with 15 candela strobe) - Part No. 429695 (sounder with 75 candela strobe) - Part No. 429696 (sounder with 117 candela strobe - Part No. 429698 (strobe, multi candela) Maximum alarm current is 2A per circuit. See chart for line distance. The operation of the NAC (Off on Reset; Off on Silence) is determined by the setting of the NAC Operation programming option. See Chapter 4 of this manual for information on setting this option. When wiring NYC Abort operation, NAC I is used for connecting bells and bell strobes associated with the investigation timer, NAC2 is used for connecting audible notification appliances, and RAC2 is used for connecting visual notification appliances. Maximum Distance from Panel to Last Notification Appliance (Feet) Alarm Current Amps 18 AWG 16 AWG 14 AWG 12 AWG Line Resistance (Ohms) 0.25 840 1335 2126 3382 12 0.50 420 667 1063 1691 6 0.75 280 445 709 1127 4 1 210 334 532 845 3 1.25 168 267 425 676 2.4 1.50 140 222 354 564 2 1.75 120 191 304 483 1.71 2 105 167 266 423 1.5 Continued on next page 3-11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0595:113 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Ansul Incorporated, One Stanton Street, Marinette, WI 54143-2542 Contact: *Jim Engman (715) 735-7411 Fax (715) 732-3634 * I DESIGN: Model Autopulse Z-10 (430525) fire alarm control unit. Power limited. Local or releasing service, automatic, manual, waterfiow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/220 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 8th Edition Standard. XLF: 7165-0026:314 I *Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 9, 2008 Listing Expires June 30, 2009 S Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE WING No. 7272-1597:105 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: TEPG - US, 91 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 430559, 430560, 430562, *T3609001 and *T360-9002 photoelectric type smoke detectors. Models 430560 and *1360..9002 employ an integral 1350F heat sensor. This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's data sheet for additional detailed system description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, *electrical/air velocity rating, and UL label. (WROVAL: Listed as photoelectric type smoke detectors for use with separately listed compatible fire alarm control units. Intended for use with separately listed Models 430567, 430569, 430570, *T3609902, *9903 and *..9904 detector bases (CSFM Listing No. 7300- 1597:107). For indoor use only. XLF: 7272-0026:219 *Rev. 05-11-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. sate Issued: JUNE 3, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1597:107 Page 1 of 1 0 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: TEPG - us, 91 Technology Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Model 430567, 430569, 430570, *T360..9901 *T360..9902 *T360..9903 and *T360.,9904 detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible heat and smoke detector heads. Refer to listee's Installation Instruction Manual for details XLF: 7300-0026:222 *Rev. 09-25-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 3, 2008 Listing Expires June 30, 2009 Authorized By.. BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING -. BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ( *TING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. *Models As.121s7sw and As.241575w lens color may be white, red, blue, green, or amber. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. c Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. *Lens color may be white, red, blue, green, or amber. Models ASWP-2475W and *AsWp.2475C audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications.. Lens color may be white, red, blue, green, and amber. Both models are suitable for outdoor use when mounted on the Model WPBB back box. Models AS-24MCWH, AS-24MCCH, *ASWP24MCWH and *ASWP..24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix CH are for ceiling mount only. Units with suffix WH are for wall mount only. *Lens color may be white, red, blue, green, or amber. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFWR Flash Rate: 60 flashes/minute Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, llOcd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd (65cd, 90cd at -40 C) MCCH: Selectable 115cd, 177cd (50cd, 75cd at -40 C) Listing No. 71250785:131 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W, ASWP- 24MCWH, AS-24MCW and AS-24MCWH are for wall mount only. Models ASWP-2475C, ASWP-24MCCH, AS-24MCCH, AND AS-24MCC are for ceiling mount only. Models with suffix - W or WH are for wall mount only. Models with suffix -c or -CH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP, AH-24WP, *ASwp..2475w ASWP-2475C, ASWP-24MCWH, and ASWP-24MCCH audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models AH-12, AH-24, -I2WP and -24WP audible devices are not suitable for the hearing impaired applications. *Rev. 10-01-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 26, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ( *TING No. 7150-1408:107 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Signal Communications Corp., 4 Wheeling Avenue, Woburn, MA 01801 Contact: Nadim Farhat (781) 933-0998 Fax (781) 933-5019 DESIGN: Models SG-32AX, SG-32B, SG-32PS, SG-325, SG-32CX, SG-33B, SG-33S, SG-33AX, SG-34B, SG-345, SG-34AX, and SG-34PS, SG-36S, SG-36AX, SG-36CX, *sG42Cx *SG..42s *SG44CX and *SG..44s noncoded manual pull stations followed by H (hex lock) or K (key lock), followed by suffix I (push bar) or 2 (no push bar) and SGB-32S indoor back box. Models SG-32PS and SG-33PS do not have suffix -1 or -2. Suitable for outdoor use when installed with Models SGB-32C and *SGB32CD back boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC, 125 VAC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. *ARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 1-3-2007 jw To This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 14, 2008 Listing Expires June 30, 2009 . Authorized By: BEN HO, Chief Fire Engineering Division ---------------------------- CYLINDER AGENT VALVE SOURCE COIL Off SUPERVISORY MODULE MAINTENANCE SWITCH IffiIHhIllHIHHllIHHIUIHIUllilllIHIIUhIU _ NI WlHIIHlHllhIllIMlllllIIffl1 I F 006554 AUTOPULSE Z-10 Agent Release Control Panel One-Line System Reference Drawing ( DETECTION AND CONTROL EQUIPMENT DATA SHEET AUTOPULSEe Z-10 AGENT RELEASE CONTROLPANEL FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (lDCs) Two notification appliance circuits (NACs) Two release appliance circuits (RACs) Two special purpose monitor inputs (SPMs) for manual release request and manual abort request Three auxiliary relays with selectable functions Easily selected activity timiig options Agent release operation includes: Automatic extinguishing release Deluge and preaction sprinkler system release Dual or single hazard area protection IDCs are selectable for cross-zoning or for activation from a single detection input Operator interface provides: Status LEDs per circuit for Alarm, Trouble, and Supervisory (where appropriate) Acknowledge, alarm silence, and system reset Operating mode and timer selection when in programming mode Compatible with Listed/Approved 24 VDC coil automatic water control valves Required system components: Coil supervision module, Part No. 430687, one per solenoid control RAC Maintenance Switch, Part No. 76498 or 76499, one per solenoid control RAC Recommended accessory (where appro- priate): Abort Switch, Part No. 76494 or 76495 SPM 1 SPM 2 led IDCs 2, 3 and 4 - INTRODUCTION Dedicated for Agent Release, Z-10 Sup- pression Release Panels provide conven- tional fire alarm control circuits and are equipped with the features required for a wide variety of single or dual hazard suppression release applications. Capabili- ties include automatic extinguishing agent release and deluge and preaction sprinkler control. Flexible I/O Capabilities. Four lDCs allow for either four separately monitored zones or two, cross-zoned connections. Two SPMs allow dedicated manual inputs for release or abort. Two release appliance circuits (RACs) supervise to the valve coils and activate the valves when required. The two NAC circuits and the three panel auxiliary relays provide status condition information. NAG I - NAC2 Easy Program Selections. The operator panel has a program mode that allows selec- tion of panel operation type and detailed operating selections using an easily selected sequential programming operation. History Log. The last 50 events are stored in non-volatile memory. This information is accessed by connecting a technician's computer to the service port which is also used to set the date and time. PANEL FEATURE DESCRIPTION J AUTOPULSE Z-10 PRODUCT SELECTION Operator Panel. The operator panel has alarm and trouble status indicating LEDs for each input and output, visible through the "eking cabinet door. Unlocking the door Wce, des access to the Acknowledge, Alarm and System Reset push-button Four Class B IDCs provide coverage for either two cross-zoned areas or four sepa- rately zoned areas. lDCs are capable of supporting up to 30 current-limited smoke detectors or electronic heat detectors as well as manual stations and other compatible contact closure initiating devices. lDCs are capable of Class A operation with an optional adapter module and can be programmed as Class C (short or open initiates a trouble) for use with current limited devices only. Two Class B Special Purpose Monitoring Circuits (SPMs) are available for monitoring of manual release or abort switch inputs only. Inputs are normally open switches. An abort switch stops release while activated and upon deactivation, the release operation occurs after a selectable time delay. Manual release inputs activate release after selec- table delays of from 0 to 30 seconds in 5 second increments. For Class B/A, Abort switches are assumed to be current limited. SPMs are programmable as style C and capable of Class A with the optional adapter module. Two Class B NACs. Rated 2 A, for reverse polarity notification appliance operation. Class A operation is available with optional adapter module. NAC operation is selectable per application. "o Class B Release Appliance Circuits s). Rated 2 A, these circuits are dedi- d to operating release control valves and actuators. RAC cutout timing is selectable as no cutout, or 10. 15, or 20 minutes. Auxiliary Power Output. Rated at 750 mA, this output can be wired as continuous or as resettable. Resettable is normally used to power 4-wire smoke detectors. Standard Auxiliary Relay Outputs. Three relays outputs are available, selectable as normally open or normally closed, rated 2 A © 30 VDC. Trouble Relay (Aux Relay 1) is energized when Normal and is de-energized with a Trouble condition. For Single Hazard Operation, Aux Relay 2 is the Alarm relay and Aux Relay 3 indicates Time Delay Started or can optionally be selected as a Supervisory relay. For Dual Hazard Operation, Aux Relay 2 is for Hazard Area 1 Alarm; Aux Relay 3 is for Hazard Area 2 Alarm. Power Supply and Battery Charger. During alarm, the power supply provides 3 A at 25.5 VDC, filtered and regulated. The temperature compensated battery charger provides 27.5 VDC for charging batteries suitable for up to 90 hour standby and 10 minutes of alarm. External battery chargers and cabinets can be used for more battery backup. RELEASE CONTROL PANEL Part No. Description Reference 430525 Basic Releasing Panel, operates Includes: Four lDCs, two NACs, with AC input of: two SPMs, two RACs, 3 A power 120/220/230/240 VAC, supply with battery charger, 50/60 Hz (auto-select) cabinet and door EXPANSION MODULES Part No. Description Reference 430529 Auxiliary Relay Module; four Two maximum relays, Form C, rated 7 A @ 12O VAC, 5A@3OVDC, unsupervised contacts Select as 430531 Two Circuit Class A Adapter Four maximum required Module for lDCs, SPMs, or NACs Batteries Part No. Description Reference 417692 7.0 AH Battery Pack, 24 VDC Select one battery shipping assembly per system standby 417693 12 AH Battery Pack, 24 VDC requirements; two batteries are included 417694 17 AH Battery Pack, 24 VCD Requires external battery cabinet 417695 25 AH Battery Pack, 24 VDC 417997 50 AH Battery Pack, 24 VDC Release Control System Modules Part No. Description 430687 Coil Supervision Module, one required per RAC; refer to pages 6 and 7 for detail 76498 or 76499 Maintenance Switch, one required per RAC 76494 or 76495 Abort Switch, select as required 431196 Abort Supervision Module MOUNTING REFERENCE INFORMATION BOX WIDTH 14-5/8 IN. (372 mm) - - - TYPICAL CONDUIT ENTRY AREA •• (CUT HOLES AS REQUIRED) II- (TOP AND SIDE VIEWS ARE SHOWN WITH DOOR INSTALLED) DOOR THICKNESS - 5/8 IN. (16 mm) BOX DEPTH 4-1/4 IN. (108 mm) 16 IN. (483 mm) 006556 (FRONT VIEW MODULE PLACEMENT REFERENCE SHOWING NOTE: FOR SEMI-FLUSH MOUNTING, CABINET MOUNTING HOLE DIMENSIONS, OPTIONAL CLASS A ADAPTER MUST EXTEND 1-1/2 IN. (38 mm) MODULES, AND OPTIONAL RELAY MODULES) MINIMUM FROM WALL SURFACE NOTE: A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND TRANSIENT PROTECTION DEVICES. THIS CONNECTION SHALL BE MADE TO AN APPROVED, DEDICATED EARTH CONNECTION PER NFPA 70, ARTICLE 250, AND NFPA 780. 0 RELEASE CONTROL SYSTEM REFERENCE Automatic Agent Release Systems. These systems automatically activate solenoid SEol valves for the release of a fire extin- ing agent (such as dry chemical, water , foam, CO2, or INERGEN) in response to fire detection device input. UL and FM Agent Release System Panels must have a minimum of 24 hours of standby power. Initiating devices must be Listed/Approved for the application, and may be wired either Class A or B. Solenoid control valves must be electrically compatible with the control panel circuits and power supplies, and are wired Class B to provide coil supervision. Deluge and Preaction Sprinkler Systems automatically activate water control valves in response to fire detection device input. UL requirements for Fire Alarm Systems Listed for Automatic Release or Deluge and Preaction Sprinkler Systems are the same as described above for Automatic Extinguishing Release Systems. FM Approved requirements for Fire Alarm Systems for Automatic Release of Deluge and Preaction Sprinkler Systems require operation of specific compatible FM Approved Automatic Water Control Valves, a minimum secondary power capacity of 90 hours, and all circuits for the automatic release initiating devices must be capable of operation during a single open circuit fault condition (Class A). Preaction Sprinkler Systems are similar to deluge systems except that normally closed rinkler heads are used and supervisory air sure is maintained in the pipe. Operation ires both an activated sprinkler head and bli activated fire detector (or fire detectors). Deluge Sprinkler Systems employ open sprinkler heads and provide water flow when the fire detection system activates a common automatic water control valve. They are used to deliver water simultaneously through all of the system sprinkler heads. This type of system is applicable where the immediate application of large quantities of water over large areas is the proper fire response. RELEASE CONTROL SYSTEM REQUIREMENTS Solenoid valves are connected as 2- wire, Class B notification circuits with only one 24 VDC solenoid valve per circuit (or two, 12 VDC solenoids in series if applicable) to ensure supervi- sion. Coil Supervision Module, Part No. 430687, must be wired electrically before the solenoid valve and located in the solenoid valve wiring junction box. For FM Approved Deluge and Preaction Sprinkler operation, initiating device circuits must be Class A, wired to Listed/Approved devices. Power supply loading and wiring distances must be per Installation, Programming, and Operating Instruc- tions, Part No. 430545. *or FM Approved Deluge and Preaction Sprinkler Systems, battery standby capacity must be a minimum of 90 hours with 10 minutes of alarm. For FM Approved Automatic Extinguish- ing Release, battery standby must be a minimum of 24 hours with 5 minutes of alarm. Battery standby must be selected for a minimum voltage of 23 VDC to ensure proper valve operation. Maintenance Switch, Part No. 76498 or 76499, are required to ensure that notifi- cation circuits dedicated for release operation may be properly disabled prior to service. (Refer to NFPA 72, the National Fire Alarm Code, Section 3- 10.4, 1996 edition or Section 3-8.4.3.4, 1999 edition.) For FM Approved Deluge and Preaction Sprinkler operation, the specified compatible Automatic Water Control Valves must be used. For UL Listed and FM Approved Auto- matic Extinguishing Release, solenoid valves must be electrically compatible. Abort Switches, Part No. 76494 or 76495, are available when abort opera- tion is required. When used, wire on Special Purpose Monitoring Circuits (SPMs) as Class A or B, the same as required for other initiating devices. Manual Release Stations are used for direct activation of the release solenoids with the appropriate time delay imple- mented by the fire alarm control panel (typically 15 or 30 seconds). LISTINGS AND APPROVALS UL Listed FM Approved CSFM (Pending) MEA (NYC) (Pending) EXPANSION MODULES AND ACCESSORIES Auxiliary Relay Module, Part No. 430529. Four relays per module are available as required. Dual hazard applications will require two modules for auxiliary relay opera- tion. Each relay module has a manual disconnect switch that controls relays 2 through 4 (Trouble Relay is not controlled). Relay outputs are required to be connected to 15 A maximum circuit breaker. Operation is per the following actions: Relay I activates on any trouble associated with its hazard Relay 2 activates on any alarm associated with its hazard Relay 3 activates with the first zone of a cross-zoned system (hazard specific) Relay 4 activates when the hazard specific RAC activates Dual Circuit Class A Adapter Module, Part No. 430531. This module converts two Class B circuits to Class A operation. It consumes no additional current and is compatible with lDCs, SPMs, and NACs. Up to four modules may be mounted within the Z-10 cabinet. Maintenance Switch. Proper service of release appliance circuits requires the ability to securely disconnect the release circuit during installation and maintenance. This module provides a keyswitch on a stainless steel single gang plate with clear functional markings. (See following illustration.) 0 NORMAL (a LOCK-OUT FIRE SUPPRESSION SYSTEM ABORT & 0 006549 Maintenance Switch Remote Battery Meter Module. For display of battery voltage and charge and discharge current. This module mounts within 3 ft (1 m) of the Z-10 cabinet using a four-gang electri- cal box. FIRE 6LfiR6 58TE1 BAT rEPY 1ETER 006551 Remote Battery Meter Module Abort Switch. For manual abort requests, a large pushbutton switch is provided. Activity abort occurs while the switch is pushed and continues after releasing the switch for the selected Abort Release Time Delay. (See illustration below.) 0 FIRE SUPPRESSION SYSTEM ABORT 0 PUSH AND HOLD 0 006565 Abort Switch FM APPROVED WATER CONTROL VALVES FM Group Manufacturer Model Number Details A Skinner LV2LBX25 24 VDC, 11 W, 458 mA, 1/2 in. NPS, 1/2 in. orifice B ASCO T8210A107 24 VDC, 16.8 W, 700 mA, 1/2 in. NPS, 5/8 in. orifice 8210A107 R8210A107 C Star Sprinkler 5550 24 VDC, part of Model D deluge valve D ASCO 8210G207 24 VDC, 10.6W, 440 mA, 1/2 in. NPS, 1/2 in. orifice HV2648581,_NO. V2648571, N.C. E Skinner 73218BN4UNLVNOC111C2 24 VDC, 10 W, 420 mA, 1/2 in. NPS, 5/8 in. orifice 73212BN4TNOONOC111C2 24 VDC, 10W, 420 mA, 1/2 in. NPS, 5/8 in. orifice; 5-300 psi rated working pressure F Skinner 73212BN4TNLVN0C322C2 24 VDC, 22 W, 1/2 in. NPS, 920 mA, 250 psi (1725 kPa),1/2 in. orifice 0 Skinner 71395SN2ENJ1NOH111C2 24 VDC, 10 W, 420 mA, 1/4 in. NPS, 1/16 in. orifice, 250 psi rated _(1725_kPa)_ _working _pressure H Viking HV-274-060-001 24 VDC, 22.6 W, 940 mA, 1/2 in. NPS, 250 PSI (1725 kPa), 3/4 in. orifice SPECIFICATIONS Power Ratings 1 AC Input Voltage Ratings Current Rating il 120 VAC, 60 Hz; 220/230/240 VAC, 50/60 Hz, auto-select 2 A maximum @ 120 VAC input; 1 A maximum @ 240 VAC input Power Supply 3 A maximum @ nominal 24 VDC Battery Charger Temperature compensated, capable of recharging batteries required for 90 hour standby and 10 minute alarm Standard Circuit Ratings (NOTE: Total DC current = 3 A maximum) Notification Appliance Circuits (NACs) 2 A maximum @ 24 VDC, per circuit Release Appliance Circuits (RACs) 2 A maximum @ 24 VDC, per circuit Initiating Device Supervisory Current Circuits (lDCs) Alarm Current Capacity 3 mA maximum 60 mA maximum Each IDC supports up to 30 detectors (smoke or electronic heat) and manual stations as required, wiring distance is limited to 50 Q maximum Special Purpose Monitoring Circuits (SPMs) For Manual Release or Abort switches only; not for detectors Auxiliary Power Output Two outputs are available, continuous operation or resettable operation; combined output is 750 mA maximum @ 24 VDC Auxiliary Relay Outputs (Trouble, Aux Relay 2, Aux Relay 3) Contacts rated 2 A @ 30 VDC, selectable as N.O. or N.C. by jumper Wiring Connections for Above Circuits and AC Input Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Auxiliary Module Ratings Class A Adapter Module, Part No, 430531 Two circuits per module, rated same as circuits (not applicable to RACs) (no additional current required) Relay Type Auxiliary Relay Module, AC Ratings Part No. 430529 DC Ratings Current Wiring Four relays with two outputs per relay; individually selectable as N.O. or N.C. 7 A @ 120 VAC, rated for pilot duty @ 0.35 power factor 5 A @ 30 VDC, rated for pilot duty © 0.35 power factor 70 mA @ 24 VDC, all four relays energized Terminals rated for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ) Coil Supervision Module Construction Epoxy encapsulated Dimensions 1-3/8 in. W x 2-7/16 in. L x 1-1/16 in. H (34 mm x 62 mm x 27 mm) Wiring 18 AWG (0.82 mm2) wire leads, color coded Current Rating 2 A Maximum Environmental Ratings Operating Temperature Range 32° to 120°F (0° to 49° C) Operating Humidity Range up to 93% RH, non-condensing cl 100.4° F (38° C) maximum I 0 I REFERENCE INFORMATION, COMPATIBLE DETECTORS Part No. Pa Type Description Data Sheet 430559 F4 30562 V430565 Photoelectric smoke detectors for 2-wire bases Standard detector Reduced sensitivity detector - F2002159 F-2002160 Combination smoke and heat detector 430566 Electronic heat detectors for 2-wire and 4-wire bases 135° F (57°C Fixed heat detector F-2002158 200° F (93°C) Fixed with rate-of-rise heat detector ALJTOPULSE Z-10 SYSTEM CONNECTION REFERENCE ELECTRICALLY COMPATIBLE ACTUATOR OR COMPATIBLE FM APPROVED DELUGE AND PREACTION AUTOMATIC WATER CONTROL VALVE, ONE PER RAC A ACTUATOR WIRING JUNCTION BOX BIk Yel L: ABORT SUPERVISION MODULE COIL SUPERVISION MODULE MAINTENANCE SWITCH WITH LAMP ABORT SWITCHES \ MANUAL RELEASE (AS REQUIRED) STATIONS SPM 1 SPM 2 IDC1 MANUAL FIRE ALARM STATION COMPATIBLE DETECTION - DEVICES IDCS 2, 3, AND 4 - RAC I AUX ' IC 1 J24VDc LL III I TYPICAL STROBE ONLY NAC NAC 1 EF I R ~E —~ TYPICAL HORN ONLY NAC NAC 2 IL- FIRE FIRE_ AUTOPULSE Z-1O SUPPRESSION ao RELEASE PANEL METER MODULE CABLE (SUPPLIED WITH METER MODULE) OPTIONAL METER MODULE NOTE: LOCATE METER MODULE WITHIN 3 FT (1 M) OF Z-10 CABINET. GENERAL WIRING NOTE: WIRING SHOWN IS FOR REFERENCE ONLY, REFER TO SPECIFIC INSTALLATION INSTRUCTIONS FOR DETAILED WIRING INFORMATION. 4 AGENT RELEASED RED LED ALARM SILENCED YELLOW I LED INDICATES THAT I AUDIBLE NOTIFICATION I APPLIANCES ARE SILENCED I PRIOR TO SYSTEM RESET SUPERVISORY AND SYSTEM TROUBLE YELLOW LEDs AC POWER GREEN LED IS ON WITH NORMAL POWER STATUS INDICATE RACs ARE ACTIVATED I EARTH FAULT YELLOW LED I INDICATES PRESENCE OF I AN EARTH FAULT — —) ABORT ACTIVE YELLOW LED TRACKS STATE OF ABORT SWITCH RELAY DISCONNECT YELLOW LED INDICATES THAT EXPANSION RELAYS HAVE BEEN DISABLED FOR SERVICE PROGRAMMING MODES AND SELECTION CHOICES RELEASE CONTROL PANELS Sequence Programming Mode Description Choices Application Mode Agent release or preaction deluge; single or dual hazard: cross-zoned, combined, cross-zoned and combined, or neither (9 choices) 2 IDC and SPM Circuit Style Class B/Class A or Style C 3 Automatic Release Time Delay 0, 10, 20, 30, 40, 50, or 60 seconds 4 RAC Cutout Timer No cutout, 10, 15, or 20 minutes 5 Manual Release Time Delay 0, 5, 10, 15, 20, 25, or 30 seconds 6 Abort Release Time Delay UL Standard 864 listed Immediate or 10 seconds remaining Not UL Standard 864 listed IRI abort (cross-zoned systems only), NYC abort, or original _release _delay 7 NAC Coding (where selectable) Temporal pattern or 20 beats per minute 8 NAG Operation No inhibit or one minute inhibit selected as: both on until silence, NAC 1 on until silence and NAG 2 on until reset, or both on until reset 9 Supervisory Latching Latching or non-latching 10 Supervisory Notification LED and tone-alert only, or with: NAG 2 also on; Aux Relay 3 also on; or both NAC 2 and Aux Relay 3 also on OPERATOR PANEL FUNCTION REFERENCE LABEL INSERT SELECTABLE FOR PREAcTI0N/DELuGE OR AGENT RELEASE, UL OR ULC VERSIONS RUN MODE: LEDs PROVIDE ALARM (RED) AND TROUBLE (YELLOW) STATUS PER IDC ZONE PROGRAM MODE: TOP TEN LEDs INDICATE PROGRAMMING MODE CATEGORY I RUN MODE: RED LEDs I INDICATE MANUAL RELEASE I ACTIVATED (FOR AGENT I RELEASE APPLICATIONS): I YELLOW LEDs INDICATE I TROUBLE FOR SPMs I (ZONES 5 and 6), NACs, and RACs I PROGRAM MODE: TOP I EIGHT LEDs PROVIDE I PROGRAMMING SELECTION ---I I ACK ACKNOWLEDGES ALARM SILENCE SYSTEM RESET RESTORES STATUS DURING RUN MODE SILENCES THE SYSTEM TO NORMAL AND ACCEPTS SELECTION AUDIBLE ALARMS DURING RUN MODE AND DURING PROGRAM MODE: TOGGLES THE SELECTION PRESS AND HOLD FOR 5 DURING PROGRAM MODE SECONDS TO PERFORM LAMP TEST 0 Detection and Control Components LiFEalarme Photoelectric Smoke Detectors For Two-Wire Bases Features LlFEalarm® Photoelectric smoke detector with on-board sensitivity drift compensation* Functional chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Multi-function indicator LED indicates normal and alarm conditions Magnetically operated functional test: Initiates alarm and verifies performance Identifies general sensitivity status using detector LED Models available in two sensitivity settings: Part No. 430559 (Part No. 430695 ULC), Standard Sensitivity, nominal 2.8%/ft obscuration Part No. 430562, Special Application Sensitivity, nominal 3.5%/ft obscuration Available base options: Bases for 2-wire operation Auxiliary alarm relay output Optional remote alarm indicating LED Description LlFEalarm photoelectric detectors provide many of the proven analog sensing features for applications where detectors are connected to conventional 2-wire initiating device circuits (lDCs). Each detector has an on-board micro- processor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. LlFEalarm detectors are packaged in a patented housing that minimizes the visibility of the air intake louvers from the normal viewing locations while maintaining a high perfor- mance smoke capture ability. Bases are available for remote alarm LED indicator connections and auxiliary relay outputs. * LiFEalarm smoke detector operation is protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,400,014; 5,543,777; 5,710,541; D383,407; 0388,352; 0392,573. 006564 LiFEalarm Photoelectric Detector Mounted in Base Listings and Approvals UL Listed ULC Listed FM Approved CSFM (Pending) MEA (NYC) (Pending) Specifications Voltage 15 to 32 VDC, from Control Panel IDC Standby Current 100 pA @ 24 VDC Alarm Current, Up to 86 mA maximum, exact 2-Wire Operation current is determined by alarm current limiting of connected I DC Auxiliary Relay Ratings Refer to page 2 under Product Selection Air Velocity Range 0-2000 ft/mm (0-610 rn/mm) UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 150 to 122° F (-90 to + 50° C) Humidity Range 10% to 95% RH from 320 to 122° F (0° to 50° C) non-condensing Color Frost White Dimensions 4 7/8 in. Dia. x 1 7/8 in. H, mounted in base (124 mm x 48 mm) 0 Smoke Detector Features Intelligent Data Evaluation. Conventional smoke detectors will typically drift toward being too sensitive due to the accu- mulation of dust and dirt. With analog detection, data from the photoelectric chamber is monitored and analyzed at the detector to provide a continuously shifting reference point. Drift Compensation. The data evaluation and its shifting reference point provide a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, establishing an accurate reference for evaluating new activity. With this filtering, the resulting drift compensation provides a significant reduction in the proba- bility of false or nuisance alarms caused by shifts in sensitiv- ity - either up or down. Magnetic Test Information. Status information is available by performing the magnetic test and observing the detector LED pulses. The LED will normally go directly into alarm with the magnetic test. If there is an off-normal condition, the LED pulses first to indicate the condition and then goes into alarm. Application Reference Detector Locations. Locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. For further detailed installation information, refer to Detectors, Sensors, and Bases Application Manual, Part No. 431424. Sensitivity Selection. The standard sensitivity detector, Part No. 430559, is recommended for most applications. When a special application for a reduced sensitivity detector is required, Part No. 430562 should be considered. Consult Ansul for assistance in determining the proper selection. LA Product Selection Smoke Detectors Part No. Description Nominal Sensitivity Compatibility 430559 and 430695 (ULC) LlFEalarm Photoelectric Detector 2.8%/ft (standard) Compatible with detector bases: Part Nos. 430567 and 430569 430562 3.5%/ft Compatible Bases Part No. Description Details 430567 2-Wire Base with connections for IDC and LED connections are screw terminals for 430701 (ULC) Remote Alarm LED Indicator in/out wiring, 18 to 14 AWG 430569 2-Wire Base with Auxiliary Alarm Relay Relay Ratings, Dual Form "C", For Suppressed Loads: 430702 (ULC) & connections for Remote LED Indicator Power limited, 1 A @ 28 VDC NOTE: Must be connected as the only device Non-power limited, 1/2 A @ 120 VAC on the IDC to ensure relay operation. Wiring Connections (In/Out where required): Relay contacts and IDC (-), color coded 18 AWG leads 430570 2-Wire Base with Remote LED Indicator 430703 (ULC) tOO (+) and LED wiring, screw terminals for 18 to 14 AWG 430572 Remote LED Alarm Indicator 430704 (ULC) Detector Accessories Part No. Description Details 430646 Adapter Plate Required for mounting to 4 in. square box, fits 4 in. octagonal box May be used when retrofitting existing bases Compatible with Part No. 430567 and Part No. 430569 detector bases 430572 Remote LED Indicator Mounted on single gang stainless steel plate E 0 Detector Status LED Indications LED Indication Status Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test * LED Indication Followed By Status j_Action LED turns ON Alarm is initiated Normal, sensitivity is within compensation range None LED pulses quickly, 6 times in 3 seconds, then turns ON Alarm is initiated More sensitive, out of normal compensation range Cleaning or other service is required LED pulses slowly, 4 times in 8 seconds, then turns ON Alarm is initiated Less sensitive, out of normal compensation range Does not initiate Alarm Detector is malfunctioning Service is required Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual, Part No. 431424, for further test and maintenance information. Dimensions and Reference Information 1/4 IN. _______________________________________ 63/8 IN. (6.4 mm) (162 mm) OPTIONAL ADAPTER PLATE, PART NO. 430646 (REQUIRED FOR 4 IN. SQUARE BOX) (I 4 718 IN. (124 mm) '1 BASE HEIGHT / 1 7/8 IN. 11/16 IN. (17 mm) T- I - - (48 mm) - LED STATUS INDICATOR (WITH CLEAR LENS) PART NO. 430559 AND PART NO. 430562 DIMENSIONS MOUNTED ON BASE 1• 008567 REMOTE RED LED INDICATOR, PART NO. 430572 (NOT TO SCALE) SIIRFACF MOIIMT RFFFRFNr,F 4 IN. (102 mm SQUARE BO 1 1/2 IN. (38 mm) MINIMUM BOX DEPTH 4 IN. (102 mm) OCTAGONAL BOX FLUSH MOUNT REFERENCE, MOUNT EVEN WITH FINAL SURFACE, OR WITH UP TO 1/4 IN. (6.4 mm) MAXIMUM RECESS Mounting Information ELECTRICAL BOX REQUIREMENTS: WITHOUT RELAY (BASE, PART NO. 430567): 4 IN. OCTAGONAL OR 4 IN. SQUARE, 11/2 IN. DEEP SINGLE GANG, 2 IN. DEEP WITH RELAY (BASE, PART NO. 430569): 4 IN. OCTAGONAL, 1 11 IN. DEEP, WITH 11/2 IN. EXTENSION RING 4 IN. SQUARE, 11/2 IN. DEEP, WITH 11/2 IN. EXTENSION RING 0 - ADAPTER PLATE, PART NO. 430646, REQUIRED FOR MOUNTING TO SURFACE MOUNTED BOXES AND TO 4 IN. SQUARE FLUSH MOUNT BOXES PART NO. 430569 INCLUDES A RELAY MODULE THAT MOUNTS IN BASE ELECTRICAL BOX SMOKE DETECTOR BASES, PART NOS. 430567 AND 430569 006506 SMOKE DETECTOR, PART NOS. 430559 AND 430562 (I EA ANSUL and AUTOPULSE are trademarks of Ansul Incorporated or its affiliates, ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-2002159 ©2003AnsuI Incorporated Lilho in U.S.A. STANDARD PULL STATION 7/8 IN. (22 mm) 4 11/16 IN. (119 mm) PULL STATION (95 mm) 3 314 IN. 7 (95 mm) 006753 3-1-01 3-32 ANSUL® Detection and Control Components Electric Manual Pull Station (S Features UL Listed/FM Approved Approved for ADA Dual action Die-cast metal construction Terminal block Optional auxiliary contacts Flush mounts on single gang box Surface mount back box available Weatherproof back box available High-gloss red enamel finish - -- Customized labels Keyed to match AUTOPULSE control units Applications The Electric Manual Pull Station is a cost-effective, feature- packed, non-coded manual fire alarm pull station. It was designed to meet multiple applications with the installer and end-user in mind. The pull station provides the AUTOPULSE control panels with an alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the pull station simple to install, maintain, and operate. Description The Electric Manual Pull Station is a high quality, die-cast metal dual action fire alarm pull station available with a SPST, DPST or DPDT switch, with terminal strip connec- tions. The contacts are rated for 1 Amp at 30 VDC. Gold plat- ing on the contacts avoid the risk of corrosion. All models in the series have been tested by UL for compliance to the lat- est requirements of the American with Disabilities Act (ADA). The Electric Manual Pull Station is operated by pushing in the top bar and pulling the handle on the front of the station as far down as it will go; at which point the handle locks into place and is easily visible from up to 50 feet. Opening the station with the key, placing the handle in the normal upright position and re-locking the station resets the pull station. 3 1/4 IN. (83 mm) WEATHERPROOF PULL STATION 411/IS IN, (119 mm) ~3 /4IN. 3114 IN. (83 mm) ...<_(83 mm) 004646 TECHNICAL INFORMATION WIRING - SPST PULL STATION 'Conventional Switch Ratings' .......................1 A @ 30 VDC 1A@I2OVAC I I Switch Type: .......................... SPST or DPST I Terminal Size' .........................Up to 14 AWG Color' ...............Red with raised white letters, white I PUSH/PULL HANDLES with raised red letters Weather Proof with Weather Proof Back Box . . . NEMA 3R I Explosion-proof - - Switch Ratings' ......................1 A@ 30 VDC, 10 A@ 120 VAC TO AUTOPIJLSE TO NEXT CONTROL UNIT DEVICE Switch Type' ................................DPDT is EOLR 004928 LUN I NUL U1411 ijuviu WIRING - EXPLOSION PROOF PULL STATION I ---1 I,I©I I I©I I _L ,, TO AUTOPULSE TO NEXT EOLR CONTROL UNIT DEVICE 004935 fl TerminalSize: ........................ LJPtO 14AVV(i WIRING - DPSTPULLSTATION Humidity: .............90% Relative at 100 OF (37.7 °F) -----1 Explosion Hazard Classifications: .Class I Groups B, C, D; Class II Groups E, F, G; Class Ill Weatherproof Classifications' ........... NEMA Type 4X Other Classifications: ................ UL Marine Listing Conduit Fittings:......................... ......2 Conduit Fitting Size' ..................3/4 in. - 14 NPT Color' ..............Red with raised white letters, white PUSH/PULL handles with raised red letters LISTINGS AND APPROVALS* UL .....................................E192508 ( ULC .......................................Listed 'Factory Mutual ...........................Approved California State Fire Marshal (CSFM) .....7150-1408:107 MEA ....................................382-94-E ORDERING INFORMATION Shipping Part Weight No. Description lb. Qgj 428655 Manual Pull Station, SPST 1 (0.45) 428656 Manual Pull Station, DPST 1 (0.45) 1-428657 Explosion Proof Manual Pull Station 1 (0.45) 428659 Weatherproof Back Box 1 (0.45) 428660 Surface Back Box 1 (0.45) 428661 Break Rod 1 (0.45) 418336 Key 1 (0.45) 428654 Label Packet 1 (0.45) Ustngs and Approvals are under Signal Communications Corporation ANSUL and AUTOPULSE are trademarks of Annul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-2001032-1 0200AnsuI Incorporated Litho in U.S.A. Ordering Information Part No. Description 76494 Abort Switch, Surface-Mount 76495 Abort Switch, Flush-Mount 76485 Extra Contact Block, N.C. 76486 Extra Contact Block, N.O. Shipping Weight lb. (kg) 1.0 (0.45) 1.0 (0.45) 0.25 (0.11) 0.25 (0.11) ANSUL I•IU~11", i ~ ...m-. .. i IU• I -.• ••UL.IILI.A•I IUIuUUUl.I.II..UU.IUI.....I.......I UeUU•U•••UU••.U.•...Ua..U..0 UU Detection and Control Components Abort Switch Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate TYPICAL WIRING DIAGRAMS ABORT SWITCH (SERIES) EOL RESISTOR / z Ø(+) '----I I I . CONTROL UNIT K. Applications N.C. ABORT ERMIN S* The Abort Switch is used to momentarily interrupt the release SWITCH - - circuit signal when the control unit is in the alarm condition. As long as the abort pushbutton is held in, the fire suppres- ABORT SWITCH (PARALLEL) sion system will not release. (Note: When the control unit is programmed for IRI compliance, the abort will not be effec- EOL RESISTOR r--- - the release circuit is activated (unless the control unit has I been reset to the non-alarm condition). IA • Description CONTROL UNIT The Abort Switch assembly consists of a momentary- N.C. ABORT SWITCH ABORT CIRCUIT contact pushbutton switch, normally-open contact block, * SEE CONTROL UNIT MANUAL FOR SPECIFIC WIRING REQUIREMENTS. normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assemblies include a single-gang weather-proof box with three 1/2 in. I.P.S. threaded conduit outlets and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC @ 1.1 amp make/break or 6 amp continuous carry. Listings and Approvals The switch is UL listed (S3623) when installed in the surface- mount box (with gasket) that is provided with the surface- mount assembly. ANSUL and AUTOPULSE are registered trademarks. MOUNTING DIMENSIONS 2 7/8 IN. (73 mm) ANSUL FIRE SUPPRESSION SYSTEM ABORT O 45/8 IN. (117 mm) PUSH AND HOLD 0 SURFACE-MOUNT JR IN FLUSH-MOUNT 2 3/8 IN. (60 mm) ii (S 3-34 ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-95111 01995Ansul Incorporated Litho in U.S.A. Key Maintenance Switch TYPICAL WIRING DIAGRAM 24 VDC ACTUATOR KEY-OPERATED CONTROL UNIT LOCK-OUT SWITCH RELEASE CIRCUIT 1 TERMINALS' - - - - N.C.Il Ordering Information Part No. Description 76498 Maintenance Switch, Surface-Mount 76499 Maintenance Switch, Flush-Mount 76485 Extra Contact Block N.C. 76486 Extra Contact Block, N.O. 78179 Spare Key 1-470273 Extender-Back Box Shipping Weight lb. (kg) 2.0 (09) 2.0 (0.9) 0.25 (0.11) 0.25 (0.11) 0.25 (0.11) 025 (011). S 4 11116 IN. (119 mm) o 0 NORMAL LOCK-OUT (00 ANSUL FIRE SUPPRESSION SYSTEM ABORT o 0 I 4 5/8 IN. (117 mm) FLUSH-MOUNT 2 314 IN. (7O mm) SURFACE-MOUNT ANSUL® Detection and Control Components Features Stackable, screw-terminal, contact blocks Compatible with AUTOPULSE® control units Surface-mount assemblies listed by Underwriters Laboratories, Inc. Components mounted on stainless steel switch plate Applications The Key Maintenance Switch is used to interrupt the release circuit signal to the fire suppression system. It is key-operat- ed to allow authorized personnel to deactivate the release circuit during service or maintenance. An indicator lamp, located on the switch plate, will light when the switch is in the Ibkotit"iode tOeriãs ãëmiñdr tht1hesjirI cuit has been disconnected. Description The Key Maintenance Switch assembly consists of a key- operated switch, 24 VDC indicator lamp, normally-open con- tact block, normally-closed contact block, and stainless steel switch plate with silk-screened label. Surface-mount assem- blies inclUde a double-gang weather-proof box and gasket. The stackable, screw-terminal contact blocks are rated for 28 VDC @ 1.1 amp make/break 0r6 amp continuous carry. Listings and Approvals The switch is UL listed when installed in the surface-mount box (with gasket) that is provided with the surface-mount assembly. I POLARITY IS SHOWN I IN ALARM CONDITION 24 VDC INDICATOR LAMP SEE CONTROL UNIT MANUALFOWSPEcIFIC WIRING REQUIREMENTS. - MOUNTING DIMENSIONS ANSUL and AUTOPULSE are trademarks ofAnsul Incorporated or its affiliates. 3-33 ANSUL INCORPORATED, ONE STANTON STREET. MAF1INETfE, WI 54143-2542 715-735-7411 Form No. F-95110-1 02003AnsuI Incorporated Litho in U.S.A. System Components UL EX-4510 6-1-02 Page 1-1.1 REV 3 In 0 P. gent systems clean.. %" I CV-98 Valve/ Cylinder Shipping Assembly Description The cylinder is factory filled with INERGEN agent. A single cylinder may be used or multiple cylinders can be manifold- ed together to obtain the required quantity of agent for total flooding. The cylinder valve can be actuated electrically, pneumatically, and/or manually with approved valve actua- tion components. All valves are equipped with an anti-recoil feature. The cylinders are shipped with a maintenance record card and protective shipping cap attached to the threaded neck of each cylinder. This cap entirely encloses and protects the valve while in shipment. The equivalent length of the valve is equal to 20 ft. (6.1 rn of 1/2 in. Sch. 40 pipe. Component Material Approvals Cylinder Steel Meets DOT 3AA2300 Valve Brass Safety Relief Valve Brass Valve/Cylinder Assembly FMRC Approved UL Listed (EX-4510) Shipping Cap Steel CD (I* Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Standard Paint 426147 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426148 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426149 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426620 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426594 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426150 435* (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies - Red Corrosion Resistant Paint 426256 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426257 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426258 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 426621 LC-350 (9.9) 355 (10.1) 217 (98) 60.2 (152.9) 10.5 (26.7) 426595 LC425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426259 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) . * NOTE: For Shanghai version, order Part No. 430935. Canadian TC Arrnroved Shipping Nominal Cylinder Actual INERGEN Approximate Dimension Dimension Assembly Size Agent Quantity Weight A B Part No. ft.3 (m3) ft.3 m3 lb. (kg) in. (cm) in. (cm) Shipping Assemblies - Red Enamel Paint 426712 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426713 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426714 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427551 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426715 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) Shipping Assemblies - Red Epoxy CR Paint 426716 200 (5.7) 205 (5.8) 128 (58) 52.7 (129) 8.5 (21.6) 426717 250 (7.1) 266 (7.5) 169 (77) 57.7 (147) 9.3 (23.5) 426718 350 (9.9) 355 (10.1) 217 (98) 59.7 (152) 10.7 (27.3) 427552 LC-425 (12.0) 429 (12.1) 246 (111.6) 70.5 (179.1) 10.5 (26.7) 426719 435 (12.3) 439 (12.4) 260 (117.9) 66.9 (170.0) 11.0 (27.9) CYLINDER SHIPPING CAP 0 PRESSURE VALVE SHIPPING CAP GAUGE RECORD VALVE TAG HEIGHT TO OUTLET CENTER 002251 I 3 1/2 IN. GAUGE REFERENCE PRESSURE (89 mm) SAFETY RELIEF VALVE ---&' / \ / 002252 CV-98 INERGEN Valve The CV-98 valve has a ten (10) year warranty. The valve requires no internal maintenance. The valve is sealed closed and must not be disassembled. If there is ever a malfunction of the CV-98 valve, the complete valve must be sent back to Ansul for warranty replacement. If the exter- nal seal is broken, the warranty is voided. NOTE: Use Flexible Discharge Bend, Part No. 427082, when attaching valve to supply pipe or manifold. ANSUL and INERGEN are trademarks of Ansul Incorporated or its aft/hales. ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2542 715-735.7411 Form No. F-9877-3 02002 Ansul Incorporated Litho in U.S.A. I ANSUL® •• IneJEAgent System Components UL EX-4510 3-1-99 Page 1-17 REV. 7 Cylinder Bracketing Description The cylinder bracketing is designed to rigidly support the installed INERGEN® agent cylinders. The bracketing compo- nents are constructed of heavy structural steel. Bracket assemblies are available in modules for two to six cylinders and can also be connected together for any combination over six. Bracketing can be assembled to support single row, double row or back-to-back rows of cylinders. Bracketing components are painted with a red enamel coating. Uprights and back frame assemblies can be bolted or welded together, which ever makes the installation more convenient. Component Material Approvals Bracketing Steel FMRC Approved UL Listed (EX-4510) S Shipping Assembly Part No. Description 845120 200 ft.3 (5.7 m3) cylinder strap (single cylinder) 845244 200 ft.3 (5.7 m3) cylinder channel with nuts and bolts (single cylinder) 845121 250 ft.3 (7.1 m3) cylinder strap (single cylinder) 845261 250 ft.3 (7.1 m3) cylinder channel with nuts and bolts (single cylinder) 845122 350 ft.3 (9.9 m3), 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder strap (single cylinder) 845245 350 ft.3 (9.9 m3), 425 ft.3 (12.0 m3), 435 ft.3 (12.3 m3) cylinder channel with nuts and bolts (single cylinder) 879638 Back frame assembly (2 cylinder) 879639 Back frame assembly (3 cylinder) 879640 Back frame assembly (4 cylinder) 879641 Back frame assembly (5 cylinder) 879642 Back frame assembly (6 cylinder) 873257 Upright, for 200, 250, 350, and 435 ft.3 (12.3 m3) cylinders (used either for right side, left side or center (center upright required when connecting seven or more cylinders in a row)) 426592 Upright, for 425 ft.3 (12.0 m3) cylinder (used either for right side, left side, or center (center upright required when connecting seven or more cylinders in a row)) 873553 Single row or back-to-back row bracket foot (left side) 873554 Single row or back-to-back row bracket foot (right side) 873555 Double row bracket foot (left side) 873556 Double row bracket foot (right side) 418508 Center upright foot 879413 Connector (required to hook together back frames for seven or more cylinders) 873250 10.5 in. (26.7 cm) carriage bolt with nut (for single row 200 ft.3 (5.7 m3) cylinders) 873251 11 in (27.9 cm) carriage bolt with nut (for single row 250 ft.3 (7.1 m3) cylinders) 873252 12.5 in. (31.8 cm) carriage bolt with nut (for single row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418502 13 in. (33.0 cm) carriage bolt with nut (for single row 435 ft.3 (12.3 m3) cylinders) 873253 21 in. (53.3 cm) carriage bolt with nut (for double row 200 ft.3 (5.7 m3) cylinders) 873254 22 in. (55.9 cm) carriage bolt with nut (for double row 250 ft.2 (7.1 m3) cylinders) 873255 26 in. (66 cm) carriage bolt with nut (for double row 350 ft.3 (9.9 m3) and 425 ft.3 (12.0 m3) cylinders) 418503 27 in. (68.6 cm) carriage bolt with nut (for double row 435 ft.3 (12.3 m3) cylinders) 873091 Cylinder clamp (2 cylinders) 873092 Cylinder clamp (3 cylinders) 871683 Weigh rail support - single row 871682 Weigh rail support - double row 871684 Weigh rail support - back-to-back rows 423027 Weigh rail support back-to-back double row Multi-Cylinder UPRIGHT Single Cylinder BACK FRAME I .- CYLINDER CLAMP CARRIAGE BOLT WITH NUT RIGHT / I I CLAMP BRACKET FOOT CHANNEL Ii Ii Ii Ii 0 LEFT BRACKET FOOT ANSUL and INERGEN are trademarks of Ansul Incorporated or Its affiliates. I ANSUL INCORPORATED, ONE STANTON STREET, MARINETrE, Wi 54143-2542 715-735-7411 Form No. F-9309-7 01993 Ansul Incorporated Litho in U.S.A. ANSUL System Components ULEX-4510 11-1-00 Pagel-18 REV 3 wo IN Agentwp._;. Pressure Switch - DPST Description The pressure switch is operated by the INERGENTM agent pressure when the system is discharged. The pressure switch can be used to open or close electrical circuits to either shut clown equipment or turn on lights or alarms. The double pole, single throw (DPST) pressure switch is con- structed with a gasketed, water tight housing. The housing is constructed of malleable iron, painted red. A 1/4 in. NPT pressure inlet is used to connect the 1/4 in. pipe from the INERGEN system. The pressure switch can be installed either before or after the pressure reducer in the distribution piping. Minimum operating pressure is 50 PSI (3.5 bar). Shipping Assembly Part No. Description 846250 Pressure switch - DPST S Component Material Thread Size/Type Electrical Rating Approvals Pressure Switch Switch: Conduit Inlet: 3/4 in. NPT Female 2 HP - 240 VAC/ FMRC Approved DPST BAKELITE Pressure Inlet: 1/4 in. NPT Female 480 VAC UL Listed (EX-4510) Housing: 2 HP - 250 VDC, Malleable 30A - 250V AC/DC Iron 5A - 480V AC/DC Piston: Brass Cover: Brass 35/8IN. -4 (9.2 cm) MALLEABLE IRON ,- - - BRASS RESET 27/8 IN. FINISH- RED PAINT ' PLUNGER - (7.3 cm) I TO ELECTRICAL EQUIPMENT TO MOISTURE-PROOF BE CONTROLLED JOINT r GASKET NUT I (I RING GASKET - I NAMEPLATE JO O DOUBLE POLE - HEAVY DUTY I 4 9/16 IN. TOGGLE SWITCH I (11.5 cm) WITH FULLY I ENCLOSED BAKELITE BASE lo o BRASS PISTON PISTON O RING © GASKET - - J MOUNTING HOLE - TO POWER ..L. 004593 3/4 IN. ELECTRICAL II CONDUIT 19/64 IN. (7.5 mm) OUTLETS id 1/4 IN. UNION —e.j - J TYP. 2 PLACES 1/4 IN. PIPE FROM CYLINDERS L 000716 BAKELITE is a trademark of Union Carbide Corp. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARINETTE, WI 54143-2542 715-735-7411 Form No. F-9327-5 ©2000 Ansul Incorporated Litho in U.S.A. I System Components ANSUL® UL EX-4510 11-1-00 Page 1-3.6 S lne&paiAgent Booster Actuator Description The Booster Actuator, Part No. 428949, is used when elec- tric actuation is required on the 1 in. selector valve, 2 in. selector valve, or the CV-98 cylinder valve. The actuator mounts directly to the component and then a HF electric actuator mounts to the top of the booster actuator. The Booster Actuator requires resetting after actuation. A Reset Tool, Part No. 429847, is available for this use. 11/4-18 UNEF 402.50 3.01 11/8-18 UNEF 006037 ANSUL and INERGEN are trademarks of Assul Incorporated or its affiliates. I ANSUL INCORPORATED. ONE STANTON STREET. MARINETFE, WI 54143-2542 715-735-7411 Form No. F-2001066 02001 Ansul Incorporated Litho in U.S.A. ANSUL® System Components UL EX-4510 11-1-00 Page 1-3.7 O Ine 0 Clean Agent systems HF Electric Actuator JS Description Electrical actuation is accomplished by an HF electric Actuator, Part No. 73327, interfaced through an AUTOPULSE® Control System. This actuator can be used in hazardous, indoor environments where the ambient tem- perature range is between 0 °F to 130 °F (-18 °C to 54 °C). The HF electric actuator meets the requirements of N.E.C. Class I, Div. 1, Groups B, C, D and Class II, Div. 1, Groups E, F, G. A maximum of two HF electric actuators can be used on a single AUTOPULSE release circuit. When utiliz- ing only one HF electric actuator, an in-line resistor, Part No. 73606, is required in the supervised release circuit. In auxiliary or override applications, a manual-local override valve actuator or a manual cable pull actuator can be installed on top of the HF electric actuator by removing the safety cap. An arming tool, Part No. 75433, is required to reset the actuator after operation. The actuator contains a standard 1/2 in. threaded female straight connector for electrical con- duit hookup. Technical Information Nominal Voltage: ..........12 VDC @ 0.57 amps Rated Voltage: Minimum: ...................12.0 VDC Maximum: ...................14.0 VDC Thread SizeIType.........1/2 in. straight female for electrical conduit hookup Material: Body ........................Brass Plunger: .................Stainless Steel Listings and Approvals UL .........................E91021 ULC ..........................1165 FM . . . . . . . . . . . . . . . . . . . . . . . . 2T8A9.AF n) 2 1/4 IN. (57 mm) 001395 ANSIJL and INERGEN are trademarks of Annul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET MARINETIE, WI 54143-2542 715-735-7411 Form No. F.2001067 02001 Ansul Incorporated Litho in U.S.A. ANSUL Ing Description The manual lever release actuator provides a manual means of actuating cylinder valves and selector valves. This can be accomplished by direct manual actuation of its pull lever or cable actuation when used in conjunction with a remote manual pull station. When used with a remote man- ual pull station, the pull station must contain the compo- nents necessary to meet the actuator lever traveling requirements of 7 in. (178 mm). The actuator is shipped with ring pin and chain attached. If the ring pin is not required, it must be removed. Failure to remove the ring pin/chain assembly will prevent system actuation if a remote cable pull actuation system is employed and the ring pin is accidentally installed in the actuator. Four actuators are available. Each is designed for a specific component. Add 19/16 in. (3.9 cm) to height when lever is in the straight up position. System Components ULEX-4510 11-1-00 Page 1-4.1 REV. Lever Release Actuator Component Material Approvals All Manual Brass with FMRC Approved Cable-pull Stainless UL Listed Actuators Steel Pin (EX-4510) Shipping Assembly Part No. Description 842484 Lever Release (1 1/4-18 mounting thread) - Mounts directly to pressure actuator on 2 1/2 in., 3 in. and 4 in. selector valves. 423309 Lever Release (1 1/8-18 mounting thread) - Mounts directly to a CV-98 electric actuator. Mounts directly to a CV-98 cylinder valve. 70846 Lever Release (1 1/4-18 mounting thread) - Mounts directly to an HF electric actuator. 427207 Lever Release (1 1/8-18 mounting thread) - Mounts directly to the I in. and 2 in. selector valves. Mounts direct- ly to pressure operated stackable actu- ator for 1 in. and 2 in. selector valves. Actuator has the handle painted red. El ANSUL and INERGEN are trademarks of Ansut Incorporated or its affiliates. n ANSUL INGORPORATEO, ONE STANTON STREET, MARINETIE, WI 54143-2542 715-735-7411 Form No. F-9879-3 02001 Ansul Incorporated Litho in U.S.A. I 10. System Components ANSUL® UL EX-4510 5-1-00 Page 1-12 In 0 REV.4 !?VR" Flexible Discharge Bend Description The valve Flexible Discharge Bend (Part No. 427082) is a 5/8 in. (1.59 cm) I.D. extra-heavy flexible hose which con- nects the valve discharge outlet to the fixed piping or head- er manifold. The discharge bend has a special female thread for connecting to the valve outlet and a male 1/2 in. NPT thread for connecting to the fixed piping or manifold. b. The discharge bend will withstand a pressure of 9000 psi (621 bar). Its flexible connection allows for easy alignment of multiple cylinder banks to fixed piping. Each bend has a built-in check valve that prevents loss of agent should the system discharge while any cylinder is removed. The equivalent length of this hose is equal to 18 ft. (5.5 m) of 1/2 in. Sch. 40 pipe. Shipping Assembly Part No. Description 427082 Flexible discharge bend 842430 Washer Component Material Thread_Size/Type Approvals Valve End Manifold End 5/8 in. Flexible SAE 100 R2 Special to 1/2 in. NPT Male FMRC Approved Discharge Bend Type AT mate with UL Listed (EX-4510) CV9O and CV-98 Valve -1 187/8 IN. (47.9 cm) FEMALE ADAPTOR (BRASS) 112 IN. NPT WASHER MALE COUPLING CHECK SWAGE ON VALVE END ____,fIi MANIFOLDIEND 000655 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARINEI1'E, WI 54143-2542 715-735-7411 Form No. F-9306-6 02000 Ansul Incorporated Litho in U.S.A. S System Components ANSUL® UL EX-4510 11-1-00 Page 1-15 r1flAeJ0. REV. Pr essure Reducer/Union Description The pressure reducer/union is required to restrict the flow of INERGEN® agent thus reducing the agent pressure down stream of the union. The 3000 psi (206.9 bar) NSCWP union contains a stainless steel orifice plate which is drilled to the specific size hole required based on the flow calculation.* The orifice plate provides readily visible orifice identification. The orifice union is available in six sizes: 1/2 in., 3/4 in., I in., 1 1/4 in., 1 1/2 in., and 2 in. NPT. All pressure reducer/unions must be installed in the piping with the orifice identification tab on the pressure inlet side of the system. The 1 1/4 in., 1 1/2 in. and 2 in. orifice unions must be installed per the direction of the flow arrow stamped on the body. VISIBLE ORIFICE IDENTIFICATION 002191 Shipping Assembly Part No. Description A B C 416677 1/2 in. NPT pressure reducer/union 2.06 in. (5.2 cm) 1.18 in. (2.9 cm) 1.95 in. (4.9 cm) 416678 3/4 in. NPT pressure reducer/union 2.38 in. (6.1 cm) 1.50 in. (3.8 cm) 2.38 in. (6.1 cm) 416679 1 in. NPT pressure reducer/union 2.63 in. (6.7 cm) 1.78 in. (4.5 cm) 2.77 in. (7.0 cm) 416680 1 1/4 in. NPT pressure reducer/union 2.94 in. (7.5 cm) 2.04 in. (5.2 cm) 3.31 in. (8.4 cm) 416681 1 1/2 in. NPT pressure reducer/union 3.31 in. (8.4 cm) 2.31 in. (5.9 cm) 3.70 in. (9.4 cm) 416682 2 in. NPT pressure reducer/union 3.56 in. (9.0 cm) 2.85 in. (7.2 cm) 4.39 in. (11.2 cm) Component Material Thread Size Approvals Pressure Reducer! Body: Forged 1/2, 3/4, 1, FMRC Approved Union Steel 1 1/4,1 1/2, UL Listed (EX4510) 2 in. NPT Orifice Plate: Stainless Steel NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. Orifice diameter must be specified when placing order. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED, ONE STANTON STREET, MARINE1TE, WI 54143-2542 715-735-7411 Form No. F-931 1-8 02001 Ansul Incorporated Litho in U.S.A. Size A-in. B-In. C-In. 1/4 in. 5/8 19/16 21/32 3/8 in. 3/4 1 5/8 23/32 1/2 in. 15/16 131/32 27/32 3/4 in. 1 1/8 25/32 7/8 1 in. 113/32 29/16 1 1 1/4 in. 13/4 23/4 1 1/16 11/2 in. 2 231/32 11/16 2in. 23/8 3 1 21/2in. 3 31/2 1 3 in. 31/2 41/8 1 1/4 0 System Components ANSUL® ULEX-4510 11-1-00 Pagel-16.1 in 0 4D REV. 2 Clean Agent tS 1800 Discharge Nozzle Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- ders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. The 180° nozzle is commonly used when nozzle placement is at the wall. Standard nozzles are constructed of brass. An index mark is stamped on the bottom of the nozzle to indicate the aiming direction. Component Material Thread Size Nozzle Body: Brass 1/4, 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2,3 NPT Shipping Assembly Part No. Description 426138 1/4 in. NPT nozzle 426139 3/8 in. NPT nozzle 426140 1/2 in. NPT nozzle 426141 3/4 in. NPT nozzle 426142 1 in. NPT nozzle 426143 1 1/4 in. NPT nozzle .426157 1 1/2 in. NPT nozzle 426144 2 in. NPT nozzle 426145 2 1/2 in. NPT nozzle 426146 3 in. NPT nozzle NOTE: Refer to Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. 22 002743 * Orifice diameter must be specified when ordering nozzle. Refer to Orifice Size Chart in Manual Appendix Section. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INCORPORATED. ONE STANTON STREET, MARINE1TE. WI 54143-2542 715-735-7411 Form No. F-99020-1 ©2001 Ansul Incorporated Litho in U.S.A. ANSUL System Components ULEX-4510 11-1-00 Page 1-16 heVa REV 6. 3600 Discharge Nozzle Description Discharge nozzles are designed to direct the discharge of INERGEN® agent using the stored pressure from the cylin- ders. Ten sizes of nozzles are available. The system design specifies the orifice size to be used for proper flow rate and distribution pattern*. The nozzle selection depends on the hazard and location to be protected. Standard nozzles are constructed of brass. NOTE: 2, 2 1/2, and 3 in. nozzles are not recommended in areas that are subject to damage by high velocity dis- charges, such as suspended ceiling tiles. Shipping Assembly Part No. Description 417908 1/4 in. NPT nozzle** 417723 3/8 in. NPT nozzle** 417362 1/2 in. NPT nozzle 417363 3/4 in. NPT nozzle 417364 l in. NPT nozzle 417365 11/4 in. NPT nozzle 417366 1 1/2 in. NPT nozzle 426155 2 in. NPT nozzle 426156 2 1/2 in. NPT nozzle 426137 3 in. NPT nozzle Component Material Thread Size Approvals Nozzle Body—Brass 1/4**, 3/8**, 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3 NPT FMRC Approved UL Listed (EX-4510) B [C 002199 Size A-in. B-In. C-In. Hex 1/4 in. 5/8 1 9/16 21/32 5/8 3/8 in. 3/4 1 5/8 23/32 3/4 1/2 in. 15/16 1 31/32 27/32 15/16 3/4 in. 1 1/8 25/32 7/8 11/8 I in. 1 13/32 29/16 1 1 7/16 1 1/4 in. 13/4 23/4 1 1/16 13/4 1 1/2 in. 2 231/32 1 1/16 2 2in. 23/8 3 1 23/8 21/2in. 3 31/2 1 3 3 in. 31/2 41/8 1 1/4 31/2 P. NOTE: Refer to "Nozzle/Pressure Reducer Range Chart" in Design Section for detailed orifice range information. ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. Orifice diameter must be specified when ordering nozzle. Refer to Orifice Size Chart in Manual Appendix Section. UUULC listed only. ANSUL INCORPORATED, ONE STANTON STREET, MARINE1TE, WI 54143-2542 715-735-7411 Form No. F-9328-9 ©2001 Ansul Incorporated Litho in U.S.A. ANSUL® System Components UL EX-4510 3-1-99 Page 1-16.2 tc tem.1 Nozzle Deflector Shield In gn Description The INERGEN® system nozzle deflector shield is used to control the pattern of the discharge of the INERGEN agent. The deflector shield helps keep the agent discharge away from false ceiling tiles and fragile light fixtures, avoiding damage to them. The deflector shields are constructed of steel and painted with a cameo cream colored paint. They are available in five sizes. Component Material Approvals Nozzle Steel FMRC Approved Deflector UL Listed (EX-4510) Shield I Shipping Assembly Part No. A Inlet NPT B Length of Coupling C Overall Length 0 Deflector O.D. E Coupling O.D. 417708 1/2 in. 1 7/8 in. 3 in. 3 3/8 in. 11/8 in. (4.8 cm) (7.6 cm) (8.6 cm) (2.9 cm) 417711 3/4 in. 2in. 31/4 in. 33/8in. 13/8 in. (5.1 cm) (8.3 cm) (8.6 cm) (3.5 cm) 417714 1 in. 23/8 in. 3 13/16 in. 4 7/8 in. 13/4 in. (6.0 cm) (9.7 cm) (12.4 cm) (4.4 cm) 417717 11/4 in. 25/8 in. 43/16 in. 4 7/8 in. 21/4 in. (6.7 cm) (10.6 cm) (12.4 cm) (5.7 cm) 417720 11/2 in. 31/8 in. 429/32 in. 521/32 in. 21/2 in. (7.9 cm) (12.5 cm) (14.4 cm) (6.4 cm) NOTE: There are no deflector shields available for the 2, 2 1/2, or 3 in. models. E A I 1 003651 0 ANSUL and INERGEN are trademarks of Ansul Incorporated or its affiliates. ANSUL INOORPOFtATSO, ONE STANTON STREET. MA.RINETEE, Wi 54143-2542 715-735-7411 Form No. F-94152-1 © 1999 Ansut Incorporated Litho in U.S.A. flECI1?C heeoc.k UL - NEW VC -; Wit-A, DA W,N SYSIIM., Helping People Take Actions TM 0 - SERIES AS SINGLE & MULTI-CANDELA AUDIBLE STROBE APPLIANCES SERIES AH AUDIBLES Description Wheelock's patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or Wheelock's patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/11 0cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-I 2/24-8CP and PS-I 2/24-8MP Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. For Weatherproof Series AS, See Datasheet S9004 Copyright 2004 Wheelock Inc. All rights reserved. SERIES AS SERIES AH 1• ;. , ., __ Multi-Candela Indicator (bottom of lens) Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information. ADA/NFPAIUFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/751110cd or I35/185cd (Multi-Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15130/75/95cd or I15/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires S NOTE: All CAUTIONS and WARNINGS are Identified by the symbol A . All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER *APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series AS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 1200 F (0° C to 490 C) and maximum humidity of 93% (± 2%). Series AH-24 horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). Series AH-24WP audible appliances are listed under UL Standard 464 for indoor/outdoor use with a temperature range of -31°F to 150°F (-35°C to 66°C) and maximum humidity of 95%. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Input Voltage VOC Regulated Voltage Range VDC/FWR Strobe Candela led) AS-24MCW 24 16.0-33.0 15130175/110 AS-24McCH 24 16.0-33.0 1151177 AS-241575W 24 16.0-33.0 15 (75 on Ads) AS-121575W 12 8,0-17.5 15 (75 on Ads) AS-24MCC 24 160-33.0 15130/75/95 AS-24MCWF1 24 16.0-33.0 135/185 ASVVP-2475W 24 16.0-33.0 75@-31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series ASIAN 12 and 24 VDC Audible Description Volume Reverberant dBA Per UL464@lOft. Anechoic dBA @laft. - Continuous Horn High 91 99 Medium Low 88 83 95 90 Code 3 Horn High 87 99 Medium 84 95 Low 79 90 Table 3: Average RMS Current Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models 24 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 135cd 185cd l5cd 30cd 75cd 95cd ll5cd 177cd 24vdc 0.062 0.100 0.080 d30cd475cdllocd 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 High (99) dBA ULmax° 0.080 0.121 0.088 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 24 vdc 0.033 1 0.080 0.060 1 0.084 0.132 1 0.173 0.230 0.305 1 0.066 1 0.092 1 0.145 1 0.186 1 0.230 0.305 Med(95)dBA UL max* 0.043 1 0.107 1 0.074 0.110 0.190 0.253 0.340 1 0.465 1 0.080 0.122 0.201 0.269 0.340 0.465 24vdc 0.017 0.072 0.052 0.076 0.121 1 0.158 0.220 1 0.295 1 0.056 0.082 0.132 0.173 0.220 0.295 Low (90) dBA UL max* 0.021 0.100 1 0.068 0.105 0.182 1 0.245 0.335 1 0.460 1 0.074 0.113 0.198 0.263 0.335 0.460 12 VDC Models Audible Wall Mount Audible Strobe * RMS current ratings are per UL average RMS method. UL max Current rating is the maximum RMS Current within the listed voltage range (16- 33v for 24v units). For strobes the UL max Current is usually at the minimum listed voltage (16v for 24v units). For aUdibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. AH-12 AS-121575W High(99)dBA 12 dc 0.163 0.260 UL max* 0.192 0.320 Med (95) dBA 12 vdc 0.076 0.195 ULmax° 0.108 0.275 Low (90) dBA 12vdc 0.039 0.175 UL max* 0.058 0.265 C I A WARNING: CONTACT WHEELOCK FOR THE CURRENT "INSTALLATION INSTRUCTIONS' (P83947) SERIES AS-24MCW, (P84023 AND P84024) SERIES AS SINGLE CANDELA, (P83519) Sales AH, (1383641) Series AH-WP AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDIN REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL AFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. THESE APPLIANCES ARE NOT DESIGNED TO BE USED ON CODED SYSTEMS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams 11 SERIES AS APPLIANCES NON-SYNCHRONIZED FROM + TO NEXT APPLIANCE - OR EOLR OR FACP PRECEDING - APPLIANCE SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE SM S "STROBE Strobe - STROBE Ctrl AS AS "Audible _tL EOLR Audible -Audible NAC Circuit SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES Audible NAC Cit. DSM #1 Strobe NAC Cit. Sync AS AS [jlL F rt1:JTr Audible NAC Cii' DSM #2 A Strobe NAC dr1 t 1 Sync 1?lA ~r.b.NAC AS0+ I C L P Audible NAC Cli DSM #3 + LP'J DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-1 2/24-8CP and PS-I 2/24-8MP F OUTPUTS EOLR 1-4 4-CLASS A OR 2-CLASS MN 1. Soñ,o PS-12124-BCP 41 For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS-12/24-8CP and P84333 for PS-12/24-8MP. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, stale, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and En The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The Series AS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service, The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet S the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS-12/24-8CP or PS-12/24-8MP Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Specifications and Ordering Information 0 der r Sync w/SM, DSM 24 12 WI C Agency Approvals ng Model d Strobe Candela 0 e Non-Sync PS-12124-8cP or VDC VDC Mounting Optlons*** Mount a Me 0Uflt BFP PS-12/24MP UL MEA CSFM FM I AS-24M0W-FR 9024 15t30/75/110 X X X - X - 1 A,B,D,E,F,H,JN,O,R,X X X X X X AS-24MCW-FW 9025 15/30175/110 X X X X - I A,B.D.E,F,H,J,N,QR.X x X X x x AS-24MC'M4-FR 3468 135/185 X X X - X - A,S,D,E.F,cH,JN,O,R,X X X X X .AS-24MCWH-FW 3469 135/185 X X X - X i - A,6,D,E,F,H,J,N,0,R,X X X X . X * AS-241575W-FR 7405 1 15 (75 on Ads) X X X - X -1A.D,EF,H,JN,O,R,X X )( X X X AS-121575W-FR 7410 15 (75 onAds) X X - X X - AB,D,E,FH,J,N,O,R,X X X X X X AS-24MCC-FR 3161 15/30115/95 X X X - - X A,B,D,E.F,H,J,NO,R.X X X X X * AS-24MCC-FW 3162 15/30/75/95 X X X - - X A,B,D,EF,GH,J,N.O.R,X i X X X X * AS-24MCCI-t-FW 3467 115/177 X X X . - X A,B,D,E.F,GH,J.N,OR,X X X X X * ASVvP-2475W.FR 9012 75 t -31SF X X X - X - I (see Data Sheet S9004) X X X X X AH-24-R 7892 - X X X - X X A,BDE,F,G-I,J,N0,R,X XX x X AH-24-W 7893j - X X IX - X X A,8,D,E,F,H,J,N,0,R.X X X X X AH-12-R 78911 X X - X X X A,B,D,E,FH,J,N,0R,X X X X X 78941 - X X - .X X x A,B,D,E,F,(H,J,NO,R.X X X AH-24WP-R 7416 [ - X x - X X K X X X - X AH-12WP-R 7415 - X X - X X X K X X X - X *PENDING Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. **For Weatherproof Series AS/AH specifications see data sheet S9004. ***Refer to Data Sheet S7000 for Mounting Options. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: Info@wheelockinc.com http://www.wheelockinc.com 3 YEAR WARRANTY Made in USA Member Distributed By: WHEELOCK, INC.. 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740 • 732-222-6880 • FAX: 732-222-2588 S8100 01105