HomeMy WebLinkAbout2819 LOKER AVE E; ; FPC2018-0353; PermitCL7city of PERMIT REPORT Carlsbad Print Date: 11/03/2021 Permit No: FPC2018-0353 Job Address: 2819 LOKER AVE E, CARLSBAD, CA 92010-6626 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090831600 Track #: Applied: 10/29/2018 Valuation: $488,355.00 Lot #: Issued: 11/02/2018 Occupancy Group: Project #: Finaled Close Out: 11/03/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: ACUSHNET - FIRE ALARM Applicant: FPContractor: NOVA SECURITY NOVA SECURITY CORY HILL 8779 COTTONWOOD AVE, # STE 103 8779 COTTONWOOD AVE, # STE 103 SANTEE, CA 92071457 SANTEE, CA 92071-4457 (619) 448-3007 (619) 448-3007 FEE AMOUNT FIRE Plan Review Per Hour - Overtime $304.00 FIRE TI Fire Alarm System $620.00 Total Fees: $924.00 Total Payments To Date: $924.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ACUSHNET T.I. 2819 LOKER AVE., CARLSBAD, CA Fire Alarm Submittal FPC20I8-0353 2819 LOKER AVE E ACUSHNET - FIRE ALARM 2090831600 10/29/2018 FPC20I8-0353 Submitted By; N*VA SECURITY 8779 Cottonwood Ave. #103 Santee, CA. 92071 619-448-3007 Cont. Lie. C-10 # 802053 Contact: Cory Hill ACUSHNET T.I. Fire Alarm Submittal Equipment List Qjy Description Model Manufacture CSFM# EX Fire Alarm Panel (EXIST) VISTA 128FB ADEMCO 7165-1645:123 1 Fire Alarm Power Supply 5494 Silent Knight 7300-0559:0123 5 Input Module 4193SN ADEMCO 7165-1645:123 10 Horn/Strobe PC2RL SYSTEM SENSOR 7125-1653:188 8 Strobe SCRL SYSTEM SENSOR 7125-1653:188 Honeywell VISTA-1 28FBPT VISTA® COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL The new VISTA-1 28FBPT provides the ultimate protection for life and property. This commercial fire and burglary control panel supports up to eight partitions and up to 128 zones/points using hardwired, wireless and V-Plex® addressable technologies. A diverse line of Honeywell initiating devices, notification appliances, communication devices, keypads, RF receivers and relays satisfy a wide range of installation requirements. The VISTA-1 28FBPT control is suitable for fire-only applications, as well as for installations requiring integrated fire/burglary systems. It is the perfect solution for medical and professional office buildings, churches and synagogues, banks, schools, strip malls, and factory or warehouse environments. VISTA-1 28FBPT is compatible with a number of AlarmNet® communication products for alarm reporting, uploading/downloading and Honeywell Total Connect Remote Services. FEATURES Eight hardwired zones standard, expandable to 128 using V-Flex addressable points/zones Supports up to 128 wireless zones (fewer if using hardwired and/or V-Flex zones) Can control eight separate areas independently (8 partitions) Common lobby partition - auto arm or disarm based upon assigned partitions Master partition - used for viewing status of all partitions Supports commercial wireless fire and burglary devices Stores up to 512 events Accommodates 150 user codes and up to 250 access card holders using VISTAKEY® Supports V-Flex addressable VISTAKEY access control (1 to 8 doors) Two on-board NACS delivering a total of 2.3A @ 12V Automatic smoke detector sensitivity maintenance testing Four-wire smoke reset using on-board Form C relay Supports Dynamic Signaling for AlarmNet Communicators Supports Internet and GSM alarm reporting Supports graphical user interfaces for burglary use (e.g. 6280 and Tuxedo Touch') Supports 61 6OCR-2 multi-LED fire keypad Upload/download via AlarmNet Communicators Carbon monoxide (CO) zone support On-board serial port for communication with WIN-PAK®, Pro-Watch® and approved third-party applications Supports Total Connect Remote Services* *Event reporting only for fire partition. VISTA-1 28FBPT Honeywell VISTA® COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES Notification Appliance Circuits (two): - Programmable - Individually silenceable False alarm reduction features: - Exit error logic - Exit delay reset - Cross zoning - Call waiting defeat - Recent close report Supports commercial hardwired, addressable V-Plex® polling loop and wireless zones Hardwired zones - Provides eight style B hardwired zones - EOLR supervised for Fire and UL burglary installations - Supports N.O. or N.C. sensors - Individually assignable to any of eight partitions (all fire zones on partition 1) - Up to 16 conventional two-wire smoke detectors each on zone one and two (32 total) Patented addressable V-Plex polling loop technology - Class B, Style 3 SLC - Supports 120 two-wire addressable points - Global polling technology for faster processing - Supervised by panel - Zones individually assignable to partitions and notification circuit (bell) output or auxiliary relay - 4,000 ft. capability without the use of shielded cable - Extender/Isolation bus modules - Eight zone - Class A and B expander module - Eight zone - Class B expander module - Single-zone supervised contact module - Single relay module for auxiliary fire functions - Supports anti-masking feature on "smart" motion detectors (e.g. DT7500SN) UL Listed wireless expansion - Supports up to 128 wireless zones/points - Supervised by control for check-in signals - Tamper protection for transmitters - Individually assignable to one of eight partitions - Supports commercial wireless smoke detectors Up to eight doors using VISTAKEY V-Plex Access Control Event reporting Local printer for event log printing Communication - Phone line, GSM and IP communicator support - Panel operation during download - Four or 10-digit subscriber account numbers Extra security feature that requires master code to allow installer into program mode (enabled through Compass Downloader) Honeywell SPECIFICATIONS Electrical Primary power: 18VAC © 72VA Honeywell No. 145 1-UL9 Control panel quiescent current draw: 300mA Backup battery: - 12VDC, 12AH min to 34.4AH max - Lead acid battery (gel type) Alarm power: 1 2VDC, 1.7A max for each notification (bell) circuit output Total 2.3A © 12V Aux. standby pwr: 1 2VDC, 1 A max Total power: 2.3A at 1 2VDC Standby time: 24 hours with 1A standby load using 34.4AH battery Fusing: Battery input, aux. and notification (bell) circuit outputs are protected using PTC circuit protectors. All outputs are power limited. Optional 24-volt kit Communications Dialer Line seize: Double Pole Ringer equiv: 0.7B Formats: ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics Dual phone line capability using 51 4ODLM module AlarmNet® Communicators GSM, i-GSM and IP Communicators Cabinet Dimensions 18" H x 14.5' W x 4.3'D Environmental Storage temp: 140 F to 158° F (-10° C to 70° C) Operating temp: 32° F to 122° F (0° C to 50° C) Humidity: 85% RH EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive Agency Listings UL864 - Control Units and Accessories for Fire Alarm Systems ULC-S559-04 - Equipment for Fire Signal Receiving Centers and Systems UL1 076 - Proprietary Burglar Alarm Units and Systems UL1 610— Central Station Burglar Alarm Units CAN/ULC-5304-06 - Signal Receiving Centre and Premise Burglar Alarm Control Units UL1 635 - Digital Alarm Communicator System Units UL365 - Police Station Connected Burglar Alarm Units and Systems UL609 - Local Burglar Alarm Units and Systems UL985 - Household Fire Warning System Units UL1 023 - Household Burglar Alarm System Units ULC-5545-02 - Residential Fire Warning System Control Units ULC/ORD-C1 023-74 - Preliminary Standard for Household Burglar Alarm System Units ULC-5303-M91 - Standard for Local Burglar Alarm Units and Systems Factory Mutual (FM) California State Fire Marshal (CSFM) FDNY Certificate #6140 VISTA-I 28FBPT VISTA® COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices 6160CR-2 - Red Fire Keypad 6160 - Burglary Keypad 6280, Tuxedo Touch', Tuxedo Touch with Wi-Fi® Graphic Keypads - Burglary 4204 - Relay Module, four Form C contacts 4204CF - Two supervised NAC circuits 5881 ENHC Series RF receivers 5883H RF receiver 6220S - System printer Two-wire Conventional Smoke Detectors System Sensor ESL DSC Horn/Strobes System Sensor Wheelock Gentex Manual Pull Stations 514OMPS-1 514OMPS-2 V-Plex (Addressable) Devices 4208U Universal Eight-zone Expansion Module 4208EX Universal Eight-zone Expansion Module (Canada) 4208SN Eight-zone Expansion Module 4101 SN Single Relay/Zone Module 42085NF Class NB Expander Module 4190SN Remote Point Module - two zones 41935N and 41935NP Two-zone Expander Modules Product specifications subject to change. ORDERING V-Plex Extender/Isolation Modules 4297 Extender/Isolator Module VSI Isolator Module V-Plex Smoke Detectors 5193SD 51935D1 5192SDTA V-Plex Passive Infrared Detectors 1525005N DT7500SN V-Plex (Addressable) Contacts 49395N-WH 4959SN V-Plex Glassbreak Detectors FG1625SN Seismic Detectors SCI 00 SCI 05 Commercial Wireless Devices 5808W3/5808W3A - Photoelectric Smoke/Heat Detector 5806W3 - Photoelectric Smoke Detector 5809 - Wireless Heat Detector 581 7CB - Wireless Commercial Transmitter 5869 - Hold-Up Transmitter 580000/580000A - Carbon Monoxide Detector 5800P1R-COM - Commercial PIR Access Control VISTAKEY® V-Plex® (addressable) Access Control VISTAKEY-SK Starter Kit VISTAKEY-EX Expansion Kit Integrates with WIN-PAK® and Pro-Watch® systems Alarm Communications U.S. GSMV4G - Digital Cellular Communicator with Two-way Voice Transport Capability iGSMV/iGSMV4G - Internet and Digital Cellular Communicator iGSMCF/iGSMCFP4G - Commercial Fire Digital Cellular Communicator with Internet iGSMHS/iGSMHS4G - High Security Internet and Digital Cellular Communicator 7845i-ENT - Internet/Intranet Enterprise Communicator 7847i - Internet Communicator Canada GSMV4GCN - Digital Cellular Communicator with Two-way Voice Transport Capability iGSMVCN/iGSMVCN4G - Internet and Digital Cellular Communicator V128FBPT Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model VI28FBPT24KT (U.S. Only) Commercial Fire and Partitioned Burglary Alarm Control Panel with External 24V Power Supply (6A, four outputs, synchronized) For more information: www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com LA1S128FBPTD/D January 2013 0 2013 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1645:0123 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawadhoneywell.com DESIGN: Models FA1600C, FA1670C, FA1700C, Vista-100, Vista-128FB, Vista-128FBP, Vista-250FBP, and Vista-32FB fire alarm control units. Power-limited. Automatic, manual, noncoded, local, remote station, central station, waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. Minimum system components: Vista 100, Vista-128FB, -32FB; Control Unit 1451 Transformer 6137, 6137-R, 6139, 6139-R Keypad *COMUL Enclosure *6160CR2 Alpha Keypad (for use with Vista series) *FA570CR Alpha Keypad (for use with First Alert series) *ECP Isolator *4146 Keyswitch *5140 DLM Backup Dialer Module *7845iENT Internet Communicator *4208U 8 Zone Remote Zone Expander *4208SNF 8 Zone V-Plex Class A Adapter *Vplex VSI Short Isolator *4204CF Supervised *41905N 2 Zone Expansion Module *4193 Serial Number Interface Module *4297 Polling Loop Extender *5881ENHC 5883-H Short Range RE Receiver RATING: Primary 120 VAC, 18 VAC Secondary, 12 VDC Standby INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to *Rev. 01-07-11 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1645:0123 Page 2 of 2 manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification, the maximum Retard/Reset/Restart period shall not exceed 30.0 seconds. Burglary and other non-fire functions were not examined. Formerly 7165-0078:174 Changed company name and number to 2011 and Honeywell Security. 9-08-10. FM *Rev. 01-07-11 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5495 1 jY4jiJ 5495 Distributed Power Module The 5495 Distributed Power Module is the most powerful and cost- effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO°, and Wheelock. The 5495's switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. Also, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery. The 5495 is the costeffective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. CONNECTION TO LOCAL FIRE CONTROL The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7kQ end-of-line resistors provided. Since the 5495 draws very Little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. F EA [U PES & BEN F` I IS (JL Listed for amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VOC filtered output voltage Four power-limited notification outputs; 2. Class A or 4 Class B. or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector! indicator Independent trouble relay AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders Built-in synchronization for appliances from System Sensor, Gentex', AMSECO'. and Wheelock Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized. UL Listed notification devices ANSI Cadence pattern output capability built-in 5495 Technical Specifications. Model 5495 Block Diagram Signal Circuit Output Signal I F- Signal I Input ________ Distributed Signal 2 Signal Circuit Output Signal 2 Power ________ Input Module 5495 Signal 3 (Optional) Signal 120 VAC ..Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) SUPERVISION The 5495 supervises a variety of functions including: Low AC power Low battery condition Earth ground fault Auxiliary output power limit condition EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the 5495 creates a trouble condition on the host control signal circuits to which it is connected. the 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. PHYSICAL Dimensions: 12.25W x 16"H x 3D (30.88 cm W x 40.64 cm H x 7.62 cm D) Fora complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Amps per output circuit: 3.0(6.0 amps total) Notification circuit output: Alarm Current (for typical voltages) drawn from main panel's notification appliance circuits. 12 VDC 6.5 mA 24 VDC One input circuit: 15 mA; Both input circuits: 0 mA No. of inputs: 2 Input configuration: 2 Class B or 2 Class A Input voltage range: 9- 32VDC Battery charging capacity: 35.OAH INDICATOR LIGHTS AC power on: Green Battery trouble: Yellow Ground fault: Yellow Aux trouble: Yellow Output troubles (1-4): Yellow ORDERING INFORMATION 5495: Distributed Power Module ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10% - 93% non-condensing) ELECTRICAL AC input: 120 VAC at 2A Output: 24 VDC at 6A Current: Standby 75mA; Alarm 205mA Auxiliary power circuit: 1 Notification circuits: 4 Output configuration:2 Class A (Style Z); 4 Class B (Style Y) (1 Class A & 2 Class B) ACCESSORIES SK-SCK: Seismic Compliance Kit AGENCY LISTINGS UL listed CSFM 7300-0559:123 Meets NFPA 72 requirements MEA429-92-EVolXlI OSHPD (CA) OSP-0065-10 For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 3503951 Rev HI 11/17 © 2017 Honeywell International Inc. Lil,rIIII CALIFORNIADEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0123 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: Models 5395 *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two 12VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listee's Installation Manual for details. NOTE: 41 *Recert 08-17-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division fl_~ SYSTEM SENSOR® I! Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95,115, 150, and 177 Horn rated at 88+dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING 0 LISTED APPROVED S5552 FM approved except 7125-16504504 04011 for ALERT rvodeto 7135-1653:0503 3057363 AV00866-02 • 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SyncsCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for tire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) InputTerminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (1175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs F, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868.02 • 12/01/2017 • Page 2 ULCurrent Draw Data ifL max.morn i'ijjp'ji (MA 1;Ii 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3,1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (rnA RMS), Ceiling Horn Strobe, Candela Range (15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 , 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 • 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135, 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 ' 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temooral Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 2.47 (62.7 mm) 1.37 (34.8 mm) 6.83 di" (173 11 6.92' (175. L-Series Dimensions a A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box .01 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box Model •TtlThr.i Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 02017 System Sensor. Product specihcat ens sobect to change without notice. Visit systernsensor.conl SENSOR Phone: 800-SENSOR2 • Fax' 630-377-6495 for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135-- AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire and *4.wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. - WaliTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDCIFWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor; Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division LI Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5495 Battery Calculation Worksheet (all currents stated in mA) P.S. ON 1ST FLOOR Device Quantity of Standby mA Alarm mA Total Device Total Device Description I Devices I Per Device I Per Device I Standby mA I Alarm mA 5495 Expander(s) I 1 1 75 1 205 1 75 205 5495 Totals 1 1 1 1 1 75 205 Notification Appliances(list all) EXISTING CKTS FULL LOAD 0 N/A 1500 N/A 0 I5CD STROBES 7 N/A 41 N/A 287 30CD STROBES 1 N/A 63 N/A 63 I5CD HORN/STROBE 6 N/A 71 N/A 426 95CD HORN/STROBE 4 N/A 165 N/A 660 Notification Appliance Totals 18 1 N/A 1 1436 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 75 Total System Alarm mA 1641 Total System Standby A/H 1.80 Total System Alarm A/H 0.14 Mm. A/H Battery Required 1.94 20% SPARE BATTERY 0.39 Recommended A/H Battery 2.32 BATTERY PROVIDED 7AH PROVIDE 2EA. I2VOLT 7A/H SEALED LEAD ACID BATTERIES WIRED IN SERIES FOR A TOTAL OF 7AH AT 24VDC MAX CHARGE CAPACITY = 33.OAH .6 AH