Loading...
HomeMy WebLinkAbout1014 LAGUNA DR; ; FPC2020-0118; PermitPERMIT REPORT (Ccity of Carlsbad Print Date: 12/01/2020 Job Address: 1014 LAGUNA DR, CARLSBAD, CA 92008-1870 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1552722001 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0118 Status: Closed - Finaled Applied: 07/09/2020 Issued: 07/22/2020 Finaled Close Out: 10/07/2020 Inspector: Final Inspection: Project Title: Description: LAGUNA TERRACE HOA -PLACE EXISTING FACU FOR THE PURPOSE OF USING A CELLULAR COMMUNICATOR INSTEAD OF THE CURRENT POTS LINE Applicant: BAY ALARM COMPANY 8205 RONSON RD, # STE F SAN DIEGO, CA 92111-2014 (858) 586-3803 FEE AMOUNT FIRE Sprinkler Monitoring - $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 FFC=b--0(9 I. PROTECTED PREMISE LAGUNA TERRACE HOA 1060 LAGUNA DR CARLSBAD, CA 92008 II MONITORING COMPANY Bay Alarm Company 5130 Commercial Circle Concord, CA 94520 800-470-1000 California Alarm Operating License Number: ACO28 EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 92111 1 (800) 470-1000 Contractor License # 880138 DMP.COM 0 0 0 0 0 0 @DMPALARMS XR150F(/XR55OF( FAR FEATURES Up to 562 two-wire smoke detector or fire initiating zones on XR550FC Up to 142 two-wire smoke detector or fire initiating zones on XR150FC Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection Up to .1 Amps 12 VDC supervised bell output Up to 506 fully programmable Form C relays Serial 3 Digital Dialer or (ID reporting to multiple receivers Eight communication paths between the panel and central station Built-in remote or on-site firmware upgrade capability 12,000 event buffer French, Spanish and English menus available Multiple onboard status LEDs Up to 100 output schedules to control relays and panel outputs 32 individual reporting areas with common areas Built-in 32-character LED annunciator on panel door Output groups deliver maximum functionality with easy programming Onboard Network Onboard 10/100 autosensing Ethernet or Wi-Fl connection Customizable check-in time and retry time Suitable for multi-site applications DMP.COM 0 0 0 0 0 0 @DMPALARMS XR15OFC AND XR55OFC FIRE PANELS The XR15ODFC and XR55ODFC provide basic fire monitoring for any single site application. The XR150DNFC and XR55ODNFC panels provide all the same basic fire monitoring as the XR150DFC and XR550DFC enhanced by the onboard Ethernet connection that allows the use of Network Monitoring". Both panels come fully assembled from the factory with the following components: Control Panel The XR150FC and XR550FC Series addressable fire panels provide complete system control for local NAC operation. Additionally, DACT, NET, or Cell communication to the central station are provided. The microprocessor-based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. Keypad Annunciator The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy to use. Transformer and Enclosure The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. FLEXIBLE COMMUNICATION The XR150/XR550 Series of commercial fire panels has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and central station. The unique DMP Serial 3 format supports 16 or 32-character users, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. REMOTE ANNUNCIATOR Install up to eight 630F remote annunciators to meet the requirements of virtually any installation. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series panels may be used with the 263 Series Cellular Communicators as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path, the 263 communicator provides the security of a communication link that continues to function, even when landlines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works over a variety of carriers in the USA and Canada. EIGHT COMMUNICATION PATHS Configure up to eight communication paths between the panel and central station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the central station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and e-mail status from the keypad. 12,000 EVENT MEMORY Allows the user to view the last 10,000 door accesses or 2,000 system events that occurred over the past 45 days. FIRE ZONE PROGRAMMING Program zones for fire, fire verify, fire retard, presignal, cross zoning, or fire supervisory. This flexibility allows the ability to match individual zone characteristics to the needs of any area in the fire installation. ZONE EXPANSION The XR150FC and XRSSOFC provide up to 574 zones, programmable for a variety of fire applications. The system provides Class B 12 VDC powered zones, two on board and four on the 715 Module, plus eight panel burglary zones. Up to 64 zones are available on 16 keypad addresses, and up to 100 zones are available on each built-in LX-Bus' using expansion modules. FIRE VERIFY This is used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. NOTIFICATION CIRCUIT EXPANSION Easily add NAC outputs to the XR15OFC/ XR550FC system. Up to three Class B modules can be mounted within the FACP. Model 865 or 866 Class B NAC Modules may be combined with a power supply to provide additional 4 Amp NAC outputs. Use an 867 on the SLC Loop to further expand NAC circuits. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The One-Man Walk test allows a single technician to check the panel response to fire, burglary, panic, and supervisory zones. BUILT-IN PROGRAMMER AND DIAGNOSTICS No programming device is required, enabling installers and service technicians to fully program the system and run diagnostics from any DMP LCD keypad. Check the electrical state of zones, find individual zone numbers, check the LX- Bus for missing, overlapping and/or extra zones, and much more, all from any DMP LCD keypad. FLASH UPDATABLE The XR150FC and XR550FC panels accept software updates using Remote Link' software. This makes it easy to perform the flash update remotely any time new panel feature updates release. FIRE PANELS OUTPUTS The XR150FC and XR55OFC allow the use of two SPDT relay outputs and four open collector outputs, which may be activated by zone or system events, by schedule, through the User Menu, or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched-ground outputs. STATUS LIST To provide maximum system flexibility, fire zones may be programmed to display at a specific keypad. In this manner, all fire zones can be monitored in one location, and other zones can be programmed to display and be monitored at different keypad locations. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® Windows°. The XR150FC and XR550FC panels include an interface connection for installers to use to connect a laptop computer. COMMERCIAL WIRELESS FIRE DEVICES The list of DMP wireless devices that have earned the UL Commercial Fire Listing include: 1103 Universal Transmitter: Two-input transmitter typically used in commercial burglary door or window applications. 1100R Wireless Repeater: Extends the communication range of DMP receivers, enabling physically larger, more reliable wireless security systems. 1100X Wireless Receiver: The 1100X Receiver supports up to 500 transmitters and satisfies all wireless applications. 1100XH High Power Wireless Receiver: Provides additional transmit and receive amplification for improved performance at greater distance or in harsh building environments. Commercial Smoke Detectors: The 1164 includes synchronized sounders, and a tamper switch. The 1164N5 is for applications with existing sounder/ notification devices. 1183 Wireless Heat Detector: The 1183 Series is a reliable, ceiling-mount heat sensor available in two versions. The 1183-135F responds if the temperature exceeds 1350. The 1183-135R adds a rate-of-rise feature that responds if the temperature increases by 15°F per minute or more. 1184 Carbon Monoxide Detector: The 1184 Carbon Monoxide Detector is the ideal choice for difficult-to- wire locations, applications where room aesthetics are critical, or where hazardous materials are present. The sensor provides an early alert of potentially harmful levels of carbon monoxide in residential or commercial installations. In addition, it also transmits trouble, tamper, and low-battery messages to the panel. - D 1164-W Commercial Listed Smoke Detector with Sychronized Sounder 850S I Manual Fire Alarm Pull Station 1100XH-W Mini-Horn Strobe I Sync Module . Motor Bell thi Horn Strobe I Sync Module 1183-135R 1103-W Wireless Rate of Rise Universal Transmitter Heat Detector 1184-W Wireless Carbon Monoxide Detector 1 1103-W Universal Transmitter 630F Remote Annunicator 711 715-8 or 715-16 Zone Expansion Module Zone Expansion Module FIRE PANELS Keypads 630F LCD Remote Fire Command Expansion Modules 710 Bus Splitter/Repeater 711 Single Zone Expansion 114 4-zone Class Expansion 114-8 8-zone Class-B Expansion 114-16 16-zone (lass-B Expansion 115 4-zone 2-wire Smoke Expansion 715-8 8-zone 2-wire Smoke Expansion 715-16 16-zone 2-wire Smoke Expansion 716 Output Expansion, 4 Form C relays, 4 Open Collector Outputs 711 Graphic Annunciator: 20 Open Collector Outputs Cellular Communicators 263C COMA Cellular Communicator 263H HSPA Cellular Communicator 263HCAN HSPA+ Cellular Communicator Canada 263L1E-V LIE Communicator for Verizon 263L1E-A LIE AT&T (Coming Soon) Auxiliary Modules 860 Relay Output Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style D Class A Initiating Circuit Module 893A Dual Phone Line Module Power Supplies 505-12/LX 5 Amps @12 VDC 505-12L 5 Amps @12 VDC 505-12A 5 Amps @12 VDC Pull Stations 850 Series Pull Stations Smoke/Heat Detectors 2W-BLX Conventional Smoke 2W[-BLX Conventional Smoke/Heat Accessories 210 Network Transient Suppressor 217 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18" Coax Extension 431 Output Harness 861 Power Distribution Module Central Station Receivers SCS-1R Network Enabled Receiver compatible with central station receivers that accept Standard (ID, DD, or DMP Serial 3 messaging SCS-VR Virtual Receiver Software only solution that runs on a server for network IP and cellular communications DMP Wireless IlOOX Receiver I100XH High-Power Receiver 1100R Repeater 1103 Universal Transmitter, External Contact 1164 Wireless Smoke Detector with Synchronized Sounder 1164N5-W Wireless Smoke Detector with No Sounder 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector Computer Software Remote Link Programming Software Dealer Admin System Specifications Primary Power (included): 16 VAC 56 VA transformer Secondary Power: 12 VDC Battery Models: 365,366,368 or 369 Output Rating: Bell Up to .1 Amps at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For installations, total bell, smoke, and auxiliary cannot exceed 1.2Amps using a56 VA transformer. Cutient Draw: 180mA Enclosure: Material (old-rolled steel (Red) Ordering Information XR15ODF(-R XR150 Fire Control Panel XR15ODNFC-R XR150 Fire Control Panel with Network XR55ODFC-R XR550 Fire Control Panel XR55ODNFC-R XR550 Fire Control Panel with Network Listings and Approvals California State Fire Marshal ((SFM) New York FDNY Refer to the XR15OF(/XR55OFC Compliance Guide (11-1330) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. FCC Part 68 FCC Part 15 Underwriters laboratories (UL) Listed ANSI/UI 864 Fire Protective Signaling For additional information, go to DMP.com/Compliance. 800.641.4282 I DMP.com 2500 N. Partnership Bled, Springfield, MO 65803 Designed, Engineered & Manufactured in Springfield, MO using U.S. & global components 4 2018 Digital Monitoring Products, Inc. I 11-1311 118143 6.8 Power Requirements During AC power failure, the XR1 50FC/XR550FC Series panel and all connected auxiliary devices draw their power from the battery. All devices must be taken into consideration when calculating the battery standby capacity. The following table lists the panel power requirements. You must add the additional current draw of keypads, zone expansion modules, smoke detector output, and any other auxiliary devices used in the system for the total current required. The total is then multiplied by the number of standby hours required to calculate the total ampere-hours required. Standby Battery Power Calculations Standby Current Alarm Current XR150FC/XR550FC Series Control Panel Qty 1 x 174mA 174 mA Qty 1 x 217mA 217 mA Relay Outputs 1-2 (ON) Qty _______ 30mA Qty _______ 30mA Switch Grounds 3-6 (ON) Qty _______ 5mA Qty _______ 5mA Active Zones 1-8 Qty ______ 1.6mA Qty ______ 2mA* Active Zones 9-10 Qty _______ 4mA Qty _______ 30mA 2-Wire Smoke Detectors Qty _______ 0.1 mA Qty _______ 0.1 mA Panel Bell Output 1500mA mA 893A Dual Phone Line Module Qty x 12mA Qty _______ x 50mA 263CCDMA Cellular Communicator Qty x 13mA Qty ______ x 13mA 263H HSPA+ Cellular Communicator Qty x 24mA Qty _______ x 28mA 277 Buzzer Module Qty x 5mA Qty _______ x 5mA 1100X Wireless Receiver Qty x 46mA Qty x 46mA 1100XH Wireless High Power Receiver Qty x 160mA Qty ______ x 160mA 860 Relay Output Module (one relay active) Qty x 34mA Qty _______ x 34mA All four relays active 138mA 138mA 865 Style Y or Z Notification Module Qty x 26mA Qty _______ x 85mA 866 Style W Notification Module Qty x 45mA Qty _______ x 76mA 867 LX-Bus Style W Notification Module Qty x 30mA Qty _______ x 86mA 869 Dual Style D Initiating Module Qty x 25mA Qty _______ x 75mA 630F Remote Fire Command Center Qty x 63mA Qty _______ x 92mA 7060/7160 Thinline/7060AAqualite Keypad Qty x 72mA Qty x 80mA 7063/7163 Thinline/7063AAqualite Keypad Qty x 85mA Qty _______ x lOOmA 7070/7170 Thinline/7070AAqualite Keypad Qty x 72mA Qty x 87mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7073/7173 Thin tine/ 7073AAqualite Keypad Qty x 85mA Qty _______ x lOOmA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7872 Graphic Touchscreen Keypad Qty x 145mA Qty x 215mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 7873 Graphic Touchscreen Keypad Qty x 143mA Qty _______ x 243mA Active Zones (EOL Installed) 1.6mA Qty _______ x 2mA* 734 Wiegand Interface Module Qty x 15mA Qty _______ x 15mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty _______ x 20mA 734N Wiegand Interface Module Qty x 146mA Qty _______ x 148mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* Annunciator (ON) Qty _______ x 20mA Wiegand Reader Qty x 200mA Qty _______ x 200mA Copy Sub-Totals to next page Sub-Total Standby mA Sub-Total Alarm ______mA *Based on 10% of active zones in alarm. Digital Monitoring Products XRI50FC/XR550FC Series Installation Guide 10 Standby Battery Power Calculations Standby Current Alarm Current 736P POPIT Interface Module Qty x 25mA Qty _______ x 25mA Radionics Popex, POPITs, OctoPOPITs Qty x __mA Qty x _mA 738AAdemco Wireless Interface Module Qty x 75mA Qty _______ x 75mA 710 Bus Splitter/Repeater Module Qty x 32mA Qty x 32mA 711 Zone Expansion Module Qty x 11 mA Qty x 11 mA Active Zone (EOL Installed) Qty x 1.6mA Qty x 2mA 714 Zone Expansion Module Qty x 7mA Qty x 7mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA 712-8 Zone Expansion Module Qty x 17mA ______ Qty _______ x 17mA Active Zones (EOL Installed) Qty x 1.6mA ______ Qty x 2mA 714-8, 714-16 Zone Expansion Module Qty x 20mA Qty x 20mA Active Zones (EOL Installed) Qty x 1.6mA Qty _______ x 2mA* 715 Zone Expansion Module Qty x 7mA Qty _______ x 7mA Active Zones (EOL Installed) Qty x 4mA ______ Qty x 30mA* 2-Wire Smokes Qty x .1mA Qty x .1mA 715-8, 715-16 Zone Expansion Modules Qty x 20mA Qty _______ x 20mA Active Zones (EOL Installed) Qty x 4mA Qty _______ x 30mA* 2-Wire Smokes Qty x .1mA Qty ______ x .1mA 716 Output Expansion Module Qty x 13mA Qty ______ x 13mA Active Form C Relays Qty ______ x 12mA 717 Graphic Annunciator Module Qty x lOmA Qty x lOmA Annunciator Outputs Qty _______ x 1 mA 521 LX, 521LXT Smoke Detectors Qty x 8.8mA Qty x 28mA* 2W-BLX, 2WT-BLX Smoke Detectors Qty x 11 mA Qty ______ x 31 mA* COSMOD2W Module Qty x 45mA Qty x 174mA*# COSMO-2W Smoke and CO Detectors Qty x 1 mA Qty _______ x 50mA*# Aux. Powered Devices on Terminals 7 and 11 mA mA Other than Keypads and LX-Bus Modules Sub-Totals this page Sub-Total Standby ______mA Sub-Total Alarm mA Sub-Totals from previous page Sub-Total Standby ______mA Sub-Total Alarm mA *Based on 10% of active zones in alarm Total Standby mA Total Alarm mA # For systems that are not central station monitored, multiply alarm current by 12. Total Standby mA x number of Standby Hours needed = mA-hours Total Alarm mA + mA-hours Total mA-hours X .001 = __Amp-hrs Required Refer to section 6.9 for standby battery selection. XR 150FC1XR550FC Series Installation Guide Digital Monitoring Products r 263EXT XR Series _ DMP.COM 0 0 0 0 0 0 @DMPALARMS Digital Cellular Communicators FEATURES Plug-and-play installation and activation of add-on communication modules Direct reporting to any DMP monitoring center receiver with no relaying or intermediary retransmission of alarm signals Power from panel with low current draw for long standby battery life Fully supervised to ensure communication Can be equipped with local or remote antenna Check signal strength indication at the keypad Supports the DMP Virtual Keypad app XR550E provides privacy for your data with DMP encryption technology XR150FC/XR550FC with 263 Series communicators have EDNY approval for network or cell primary communication DMP Adaptive Technology " switches communication paths while maintaining supervision if the current path becomes unavailable on the XR Seriestm panels 263EX1 Cellular Extension Modules extend cellular reach up to 300 feet using a single wired connection without losing dB strength CELLULAR COMMUNICATORS PRIMARY OR BACKUP PATH Configure your DMP digital cellular communicator as the primary path, providing installation flexibility and cost savings. For commercial fire applications, the 263LTE can be used as a stand-alone communicator without the need for a backup. Cellular is the right choice for locations not easily reached by phone or land lines, or where there are concerns that physical communication links might be tampered with. Your cellular communicator can also be a backup communication path, providing the security of a communication link that continues to function, even when land lines are cut or compromised. FULLY SUPERVISED You're kept fully informed of system status. The unit sends full reporting messages including Zones, Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ADAPTIVE TECHNOLOGY TM If the primary communication path is compromised or becomes unavailable, Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available, communications can be programmed to switch to another path as necessary. The check-in frequency and programming for a backup path adapt to the check-in programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. DIRECT DATA TRANSMISSION The digital cellular communicators transmit IP data packets directly from the panel's processor over the LTE wireless data network. All of the messages that are capable of being sent by the control panel are received directly by the DMP monitoring center receiver. There are no intermediary servers or network operation centers, and no retransmission or reinterpretation of the information. Direct reporting means faster response, with no concerns about signals not being properly relayed or intermediate communication links failing. CELLULAR SERVICE FLEXIBILITY With SecureCom Wireless from DMP, you have a one-stop resource for both hardware and cellular service. DMP digital cellular communicators, whether selected as original equipment in a new panel or added to an existing panel via an expansion card, are ready to use the SecureCom service. VIRTUAL KEYPADTM APP The DMP app provides users with the ability to access a number of system functions remotely via a cellular or Internet connection. As a dealer, you can brand the app using your company logo. VIRTUALKEYPAD.COMTM Users can access their security system via Internet connection on a tablet or computer. Customers log into VirtualKeypad.com with their login and system user code. 263LTE CELLULAR COMMUNICATORS For existing XT/XR Series panels not originally configured with cellular communications, the 263 Series expansion cards let you add cellular capabilities. The 263LTE allows alarm messages to be communicated to an SCS-1R or SCS-VR Receiver over their respective HSPA+ or LTE networks. It provides a fully supervised alarm communication path over the network. The 263LTE is installed in the panel enclosure and powered by the panel so no additional enclosure, power supply, or battery backup is needed. Plug-and-play installation makes upgrading your panel quick and easy. The 263LTE includes an embedded SlM card for easy activation. All modules are ready for activation with SecureCom Wireless. 263EXT CELLULAR EXTENSION MODULES The 263EXT comes with a module that installs directly on the control panel inside the enclosure. Also included is a second remote module to install with a cell modem in the attic or wherever signal strength is best. Between the two, you can have up to 300 feet of continuous reach with a CATS cable or 22 AWG shielded wire. The modules communicate with each other through a single wired connection, maintaining dB signal. With DMP's 263EXT Cellular Extension Modules, you can extend cellular reach without losing a single dB. The modules are compatible with all 263 type modems and with all XT and XR Series panels. 26511E CELLULAR COMMUNICATORS XTLplus Series panel users can plug in the 265LTE cellular communicators to quickly and easily incorporate cellular communications. In the panel plastic, it requires no additional enclosures, power supplies, batteries, cabling, or conduit connections. The 265LTE contains LTE technology. It includes an embedded SIM card for easy activation. All modules are ready for activation with SecureCom Wireless. Specifications Primary Power 12 VDC from panel Current Draw (263L1E) Standby 14 mA Alarm 14 mA Current Draw (265LTE) Standby 13 mA Alarm 13 mA Ordering Information 263L1E-W381-2 AT&T LIE Cellular Communicator, Xr/XR Series 263LTE-A AT&T Cellular Communicator, XI Series 265LTE-A AT&T Cellular Communicator, XTLpIus 263LTE-V Verizon LIE Cellular Communicator, XTjR Series 263EX1 Cellular Extension Modules, XT/XR Series 265LTE-V Verizon LTE Cellular Communicator, Xllplus Accessories 381-2 18' Coax Extension 381-12 12' Coax Extension 381-25 25' Coax Extension 383 Dual Band Antenna 386 Wall Mount Antenna Bracket 381-2 2 dB Attack Enclosure Antenna 381-4 4 SMA to N Extension Cable 387-8 8 SMA to N Extension Cable 387-25 SMATO N CABLE, 25F1, LMR195 387-50 SMA TON CABLE, SOFT, LMR195 388-1 3 d Fiberglass Antenna w/bracket 388-2 2 dB Attack Enclosure Antenna 388-3 3 d MEG Antenna Certifications California State Fire Marshal (CSFM) New York City (FDNY COA #6167) Underwriters Laboratories (UL) Underwriters Laboratories Canada (IJLC) For additional information, visit DMP.com and select Compliance. 800-641-4282 I DMP.com 2500 N. Partnership Blvd, Springfield, NO 65803 Designed, engineered & manufactured in Springfield, NO using U.S. & global components LIMITED WARRANTY: DMP warrants that the products manufactured by DMP and described herein shall be free from defects of manufacture, labeling, and packaging for a period of three (3) years from the Invoice date to the original Buyer, provided that representative samples of the defective products are returned to DMP for inspection ... Te read the full DMP Limited Warranty, go to DMP.com/Warranty or check the DMP Price List or Catalog. © 2019 Digital Monitoring Products, Inc. I LT-1021 119094 DMP.COM 0 0 0 0 0 0 @DMPALARMS Zone Expansion Modules FEATURES Provides (lass B zones for burglary and fire Compatible with DMP Panels that allow zone expansion Suitable for mounting near protection devices Connect devices using four-wire bus Easily mount attractive cases on wall or three-gang box Compatible with all panel zone types Easy connection to four-wire keypad or LX-Bus Proven design ensures stability and performance Data LED on zone expander indicates good panel communication Durable and attractive plastic or metal housing Low current draw Can be powered from panel or auxiliary power supply DMP.COM 0 0 0 0 0 0 @DMPALARMS - I USE ON THE DMP IX-BUS The modules can be used on the LX-Bus of DMP panels. The modules connect to the four-wire bus and use only one zone address. To assign an additional zone expander use the next available zone address. CONNECT TO KEYPAD BUS You can also use the modules as an addressed device on the keypad data bus of DMP control panels. Simply set the module to an available keypad address and connect the wiring to the appropriate screw terminals. SIMPLE ADDRESSING Address the 711, 714, 714-8, 714-16, 715, 715-8, and 715-16 modules by setting two onboard rotary switches with a small screwdriver. The 712-8 uses slide dip switches. EASY INSTALLATION Zone expansion modules are mounted in a decorative plastic housing suitable for installing outside the panel enclosure, such as on walls or single gang boxes. After all wiring connections are made, the covers go on to form tight-fitting protection against incidental contact or tampering. 714-8, 714-16, 715-8, and 715-16 Zone Expanders are housed in a rugged, 20-gauge, cold-rolled steel enclosure. You may also mount the 708 and 710 modules inside a DMP enclosure using the three-hole configuration and the provided standoffs. The 712-8 only mounts using the three-hole configuration and provided standoffs. ZONE PROGRAMMING Program the zone on the modules with any of the panel's available zone types for use in burglary applications including arming type zones when used with keyswitches. The expansion zones are programmable for annunciation on DMP keypads connected to the panel. Each zone can also be individually programmed to report alarms, troubles, and restorals to remote DMP SCS-1R Receivers. 708 BUS EXTENDER MODULES The 708 Bus Extender Modules allow you to increase the length of wire used to rur an LX-Bus or keypad bus by a maximum of 4,000 feet, while providing immunity to noise on the wires. This model comes as a pair of modules that connect between the panel and LX-Bus or keypad bus devices. Use the 708 modules for applications that include running wire over long distances, through noisy environments, or where the bus is bundled with other wires, such as telephone company wire. The 708 extender can be used on all DMP panels. 708 FEATURES Extends keypad Bus or LX-bus by 4000 feet with one pair of modules Connects to an auxiliary power supply for added power Uses existing wire: No need to run additional wire Allows twisted pair and/or shielded wire between the 708 modules 710 BUS SPLITTER/REPEATER MODULE The 710 Bus Splitter/Repeater Module allows you to expand the typical LX-Bus or keypad bus installation both in the number of devices and the length of the wire used. Each 710 module provides three bus connections up to 2,500 feet. When using multiple modules, the total distance of all circuits can be an incredible 15,000 feet! 1cs to os U I I 710 As a splitter, the 710 provides superior mechanical wire connecting capability for up to three additional 12 VDC LX- Bus or keypad bus circuits. This makes the 710 module an excellent junction box when terminating multiple LX-Bus/ keypad bus runs at one location. As a repeater, the 710 module can be installed at the end of an LX-Bus or keypad bus circuit to allow an additional circuit to be added, thus increasing the total wire length. 712-8 ZONE EXPANSION MODULE Expand your system at an affordable price! You can connect non-powered burglary devices to DMP panels using the 712-8 Module. It is compatible with many intrusion contacts, glassbreak detectors, motion detectors, and intrusion detectors. 712-8 FEATURES Eight grounded, addressable burglary zones Set jumper for LX-Bus or keypad bus operation Compatible with all DMP panels Expand systems by daisy-chaining a second 712-8 Easily address using dip switches Snaps into panel enclosure using three-hole pattern Separate zone 1K End-of-Line resistors included 714-8/714-16 EXPANDERS SALES APP BUILD A SYSTEM 714/715 ZONE EXPANDERS The 714 contains four Class B burglary zones and is suitable for use with burglary and fire devices that are normally opened or normally closed. Individual zones are supervised with 1 k ohm End-of-Line (EOL) resistors and can be programmed with any burglary or fire zone type. The 715 contains four Class B powered zones and is suitable for use with 12 VDC, two-wire smoke detectors, and non-powered fire or burglary devices. Individual zones on the 715 are supervised with a 3.3 k ohm EOL resistor and can be programmed with any burglary or fire zone type. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 718T Plug-in Screw Terminal. The enclosure can also accommodate the 7191 Terminal Boards for the 714 or the 720T Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1 K EOL resistors are included with the 719T and 3.3 K resistors are included with the 7201. 714/715 FEATURES Four protection zones on each module Comes with 12-conductor wire harness Optional 12-position screw terminal 714-8, 714-16, 715-8, AND 715-16 The expanders are housed in a model 340 locking metal enclosure suitable for mounting in a remote location. Each expander provides screw terminal strips for zone inputs and data bus connections, a two position jumper to designate connection to the keypad bus or the LX-Bus, and an LED to indicate communication with the panel. Separate zone EOL resistors are included with each expander. The 714-8 Expander contains eight Class B zones. The 714-16 Expander contains 16 Class B zones. Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1 k ohm EOL resistor and can be programmed as any zone type. 715-8/715-16 EXPANDERS The 715-8 Expander contains eight Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 VDC two- wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3 k ohm EOL resistor and can be programmed as any zone type. 714-8, 714-16, 715-8, AND 715-16 FEATURES 8 or 16 protection zones per expander Durable metal enclosure housing with lock and key Individual screw terminals accommodate 14-22- gauge wire for easy connection Suitable for mounting in a remote location 711 DESCRIPTION The 711 Zone Expansion Module connects to the panel's four-wire keypad bus or LX-Bus and is set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. rr4o- 711 FEATURES Single-zone expander Rugged screw terminals accommodate 14- 22- AWG wire Board fits in Radionics PUPIl housing Easy rotary switch addressing illS DESCRIPTION The 711S Zone Expansion Module is a flying lead style, single-zone, addressable expansion module that allows you to increase the number of reporting zones available on XT30/50 and XR150/550 Series panels. It's ideal for smaller applications, such as installing in a pull station back-box or even in a recessed contact hole behind the contact. The modules connect to the panel is four- wire keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711S provides one Type A Class B zone. 108 (Non-UI) Bus Extender Module Operating Voltage 8.8 to 15.0 VDC Operating Current 20 mA per pair Dimensions 4.5W 2.15" H x 1.15" D Maximum Distance 4,000 feet between the two 708 modules 710 Bus Splitter/Repeater Module Operating Voltage 8.8 to 15.0 VDC Operating Current 30 mA Dimensions 4.5W *2.15" H 1.15" D Distance 2,500 feet (one module), 15,000 feet maximum 711 Zone Expansion Module Operating Voltage 8.8 to 15.0 VDC Operating Current Average 11 mA + 1.6 mA per active zone Alarm 11 mA + 2 mA per zone in alarm Zone Voltage 5 VDC 0.6 mA across EOL) Dimensions 4.5W x 2.15" H *1.15" D illS Zone Expansion Module Operating Voltage 8.8 to 15.0 VDC Operating Current Standby 4.2 mA Alarm 4.1 mA Zone Voltage 5 VDC, max 2 mA Dimensions 1.25" W *2.15" H 712-8 Zone Expansion Module Operating Voltage 8.8 to 15.0 VDC Current Draw 11 mA + 1.6 mA per active zone 11 mA + 2 mA per zone in alarm Dimensions 4.5" H *2.5" W ZONE EXPANSION MODULES ZONE EXPANSION MODULE COMPARISON CHART Refer to the chart below for a comparison of the features for each DMP Zone Expansion Module. No 708 N/A N/A 710 N/A N/A 712-8 Dip Switch 8 711 Rotary 1 7115 Rotary 1 714 Rotary 4 Class B 714-8 Rotary 8 Class B 714-16 Rotary 16 Class B 715 Rotary 4 Class B 715-8 Rotary 8 (lass B 715-16 Rotary 16 Class B Yes Yes 12 VD( Yes Yes 12 VDC Yes No 12VDC No Yes 12 VDC No 12 VD( No Yes 12 VDC No Metal Enclosure 12 VDC No Metal Enclosure 12 VDC No Yes 12 VD( No Metal Enclosure 12 VDC No Metal Enclosure 12 VDC All DMP XI Series and XR Series 714/715 Zone Expansion Module Operating Voltage 8.8 to 15.0 VDC Operating Current 114 Average 1 mA + 1.6 mA per zone Alarm 1mA2mA per zone 715 Average 7 mA + 4 mA per zone + 0.1 per 2-wire smoke Alarm 1 mA + 58 mA per shorted zone + 0.1 per 2-wire smoke + 30 mA per smoke in alarm Dimensions 4.5W *2.15" H *1.15" D 714-8,714-16,115-8, and 715-16 Zone Expansion Modules Operating Voltage 8.8 to 15.0 VDC Operating Current 114-8/16 Average 20 mA + 1.6 mA per zone Alarm 20 mA + 2 mA per zone 715-8/16 Average 20 mA + 4 mA per zone0.1 per 2-wire smoke Alarm 20 mA + 58 mA per shorted zone + 0.1 per Enclosure Dimensions 714-8/-16 Color 115-8/-16 Color 2-wire smoke 30 mA per smoke in alarm 20-gauge cold-rolled steel 12.5" W 11.5" H *35" D Gray 800-641-4282 I DMP.com Red 2500 N. Partnership Bind, Springfield, NO 65803 Certifications Refer to the appropriate panel programming and installation guide for specific compliance listings for installation and programming requirements necessary to meet a particular approval. California State Fire Marshall (CSFM) New York City (FDNY COA #6167) (711,114,715 only) Underwriters Laboratories (UL) Listed For additional information go to DMP.Com/Compliance. Designed, engineered & manufactured in Springfield, NO using 8.5.8 global components LIMITED WARRANTY: DMP warrants that the products manufactured by DMP and described herein shall be free from defects of manufacture, labeling, and packaging for a period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the defective products are returned to DMP for inspection To read the full DMP Limited Warranty, go to DMP.comfWarranty or check the DMP Price list or catalog. @2019 Digital Monitoring Products, Inc. I LT-0232 119271 r SYSTEM $ SENSOR® Photoelectric Smoke Detectors System Sensor's i3 series smoke detectors represent significant advancement in conventional detection. The /3 family is founded on three principles.' installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings & <~> 0 MEA MSFM LISTED APPROVED approved approved S911 3011446 7272-1209210 290-01-0 2093 Installation ease. The P line redefines installation ease with its plug-in design.This allows an installer to pie-wire the bases included with the heads. The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors. To complete the installation, j3 heads plug in to the base with a simple Stop-Drop 'N Lock' action. Intelligence. P detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the P line to minimize nuisance alarms. Two-wire i3 detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the P protocol. This signal is indicated by LEDs located at the module and the panel.The SENS-RDR, a wireless device, displays the sensitivityof j3 detectors in terms of percent per-foot-obscuration. Instant inspection. The j3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk ioop test feature is available on two-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. (j Smoke Detector Specifications Smoke detector shall be a System Sensor il Series model number listed to Underwriters Laboratories DL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pie-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 uA maximum averaae: 4-wire: 50 iA maximum averane Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz. (178 grams) Operating Temperature Range 2W-B and 4W-B: 32°F-1 20°F )0°C-49°C); 2W1-B and 4WT-B: 32°F-100°F (0°C-37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.50/o/ft. nominal Input Terminals 14-22 AWG Mounting LED Modes 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Power Up Sequence forLED1Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information ThermalModel 1 Vifli,i. 2W-B No AlarmTTIT 2-wire 130 mA max, limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA Pr IN 23mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12V, 23mA @ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter STEM SENSOR Phone: systern Sensor 3825 Ohio Avenue. St. Charles, IL 601 74 Prci Vet sytterttserttot com 800-SENSOR2. Fax: 630-377-6495 current pioduct,nformstion, including the ats,a version ofthis data shest - A CUSTOM DOCUMENT ENCLOSURE SYSTEM RECOO OC1itEN1S Modified Mier BW-1 06R for Bay Alarm 12"W x 12"H x 4"D Durable Red Texture Powder-Coat "SYSTEM RECORD DOCUMENTS" graphic printed in white, on two lines, on the door Rugged construction & 10.5-inch, one-piece, piano hinge for added strength Key holes for quick and easy mounting 1/4-Turn Thumb-Latch installed, as well as holes in place for bolting the door shut. Will also work with Mier's cam locks Two electrical knockouts on left side, right side, and back as well as one electrical knockout on top and on bottom Additional customization of this enclosure, or assistance in designing a new model, including color and/or graphics, is available by calling or emailing Mier Products,lnc. 800-473-0213 1 infomierproducts.com I www.mierproducts.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:0135 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products, Inc.2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Amy Bade (417) 831-9362 Fax (417) 447-9698 Email: abade@dmp.com DESIGN: Models XR150, XR350 and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listees data sheet for additional detailed product description and operational considerations. System components: XRI50, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders *711S: Zone Expander (NOT for use with XR350) Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 263H: Cellular Communicator (May be used as the standalone primary communicator) 263LTE: Cellular Communicator (NOT for use with XR350) (May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RF Wireless Receiver IlOOR: Wireless Repeater 1103: Wireless Transmitter *Rev 04-05-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7165-1157:0135 Page 2 of 2 1135: Wireless Siren RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. *Rev 04-05-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Irv " operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTIL.LO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION F ft-2 OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-13 and 4Wr-13 are 4-wire detectors. Models 2WT-B and 4WT-13 employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 a W 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftvl operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division