Loading...
HomeMy WebLinkAbout3144 EL CAMINO REAL; 100; FPC2018-0172; PermitPERMIT REPORT (C ity of Carlsbad CARLSBAD, CA 92008-2194 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2018-0172 Status: Closed - Finaled Applied: 06/05/2018 Issued: 06/13/2018 Finaled Close Out: 02/22/2021 Inspector: Final Inspection: Print Date: 02/17/2022 Job Address: 3144 EL CAMINO REAL, #100, Permit Type: FIRE-Construction Commercial Parcel #: 1670907300 Valuation: $100,057.12 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: SPEC SUITE 100 -SPRINKLER TI (13 HEADS) Applicant: FPContractor: EPIC FIRE PROTECTION INC EPIC FIRE PROTECTION INC ADAM BOISVERT 765 TURTLE POINT WAY 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 SAN MARCOS, CA 92069-8126 (760) 310-6122 (760) 310-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DES CRIPTION AND OPERATiON The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. TECHNICAL DATA PENDENT VERTICAL 'See reverse side for Approvals and Specifications. SIDEWALL -Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) _4APV0%01__ -Water Working Pressure Rating - 175 psi (12 Bars) TUV 411M Factory tested hydrostatically to 500 psi (34 Bars) -Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE Frame - bronze • Deflector - brass ° Screw - brass HORIZONTAL LPC/CE Lodgement Wire -stainless steel • SIDEWALL HORIZONTAL Bulb seat - copper • Spring -nickel alloy • Seal - teflon SIDEWALL Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RAT1NGJCLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P,A. MAXIMUM CLASSIFICATION TEMPERATURES BULB COLOR CBUNG TEMPERATURE ORDINARY 13!F/i557 57'C/6°C ORANGE/RED 103P INTERMEDIATE 175 P1260 F 76 C1S C YELLOW/GREEN 0 F 6&C HIGH :'286'F 141 C BLUE 2F .,. ___107 C 4077AIRPARKDRIVE, STANDISH. MICHIGAN 48658 9894346-4586 • FAX989846-9231 JULY 2012 A-20 BULLETIN GL5615, REV. #9 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT. VERTICAL SIDEWALL HORIZONTAL SIDEWALL. CONVENTIONAL (OLD STYLE) SPECIFICATiONS NOMINAL K FACTOR THREAD SIM I LENGTH' FINISHES 1 2.8 (39 metric) 112" NPT 2 114(5.7cm) I Factory Brore I 4.2 (59 metric) 1)2" NPT 21/4" (5.7cm) 5.6 (80 metric) 1)2" NPT I 2 114(5.7cm) Chrome I I White Polyestef° I 7.8 (111 metric) 1/2" NPT I 2114" (5.7cm) 8.1 (116 metric) 3/4" NPT 27/16" (62cm) Black Polyester 2A METRIC CONVERSIONS ARE APPROXIMATE HORIZONTAL SIDEWALL 1529116'. 'FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS oULsa LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K HP,Z , 133'F INTF 175F 'F 206'F ,,,_ FM ,PC CE NYC.DOS MODEL FACTOR 57'C BWC 79'C 82'C 141C MEA 101.92.6 013315 28 lii X S X X S S - - - S 0L4215 4.2 S. UI S X S X S X - - - S UPRIGHT GLS8IS LHIOH X S X X S X 5 5 5 5 GIBIIS 7.0' LR'OH X X S S S X - - - S 018116 El LWOH X X S X S X S S X S 00811 28 UI S S S S X X - - - S OL1 4.2 UI S S S S 5 5 - - - S PENDENT 013811 St Lt4IOH S S S X X S X S S S 018101 7.8' LHIOH S X S S S S S 013181 8.1 LH/OH S S X I S X S S S S S VERTICAL GL 5.6 UI X X S S X S S - - - SIDEWALL1 013133 8.1 UI S X S X X X - - - - 0333352.9 UI S X X X X X - - - S HORIZONTAL 0L4330) 42 UI S S S X S S - - - S SIDEWALL GLSBS9 5.6 LWOH X S X S S X S - - S 01.81275 5.6 LWOH S S X S X GLe1275 El UIIOH S X S S S S - -, - - CONVENTIONAL 015924 5.8 LWOH S X S S X - (OLD STYLE) 01.8101 El LWOH X X X X X - ISPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY 071-lEN RELATED DOCUMENTS. §HORIZONTAL SIDEWALL .UL- LISTED FOR DEFLECTOR 4' TO 12' BELOW THE CEIUNI3. FM APPROVED 4' TOW BELOW THE CEILING. INSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. 'PENDENT VERTICAL SIDEWALL oUL- LISTED FOR 6' MIN. SPACING. YLIPRIGHT VERTICAL SIDEWALL OULS LISTED FORE MIN. SPACING. ON ORDINARY HAZARD LII LIGHT HAZARD '112' NPT ORDERING INFORMA liON GLOBES PRODUCT WARRANTY SPECIFY Quantity ' Model Number - Style Globe agrees to repairer replace any of its own manufactured Orifice - Thread Sizes • Temperature products found ID be defective in material or workmanship for a 'Finishes desired period of one year from date of Shipment -Quantity - Wrench - P/N 325390(1/2') For specific details of our warranty please refer to Price List P/N 312366 (LO.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48656 G 989-846-4583 FAX 989-846-9231 FIRE spR1fWLER CORPORATION 14800-248-0278 wA'w.gtubesprinkter.cOnl JUNE 2012 PRINTED U.S.A. BULLETIN GL5615, REV. #9 CIA; BE FIRE SPRINKLER CORPORATION QUICK RESPONSE UPRIGHT CONVENTIONAL ISM 49 - QUICK RESPONSE As the Leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppression. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. 0.6 (ini In Elnpty Weight (Iblft) Water Filled Weight (Ib/ft) 1.29S 1.6so 1.900 237S 2.070 2.754 1.461 1.860 2.547 3.468 3.309 4.842 Pieces per LIft 70 51 44 30 1 ift Weight (10s) 21' lengths Ift 2,MS 2,217 2,353 2,084 Lift Weight Qbs) 24' lengthS 2,454 2,M 2.690 2,382 2,639 2,602 2,401 EDDYTHREAD 40 ADVANTAES: UL Listed (US & Canada) and FM approved ASTM A135 and A795 Type E, Grade A Certified Complies with N17PA-13, 13R and 14 Industry-leadinghydrauUc characteristics CRR of 1.0 andgreater. Alipipe NDT weld tested 71 ..P QRBUACI( PAINTEDPIPE . OTHER ENEFllTS/SERVCES: We have the most stocking locations in the industry, for best delivery and availability Plain end or roll groove Eddy Guard II' bacterial-resistant Internal coating Custom Length options Hot dipped: galvanization Reddi-Piperedor black pipe eliminates field painting Compatible for use in wet, dry, preaction anddetuge sprinkler systems The only maker With EPDs (to help earn LEED points). EURM c®us LISTED A ONFSA r. APPROVED NFPA Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2' thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe typos and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. o (2/i' thru 8" Spring tension on nut holds it securely in hanger before installation, Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10, Maximum Temperature -- 650F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200WON, Order By - Figure number and pipe size 13 8 ./ A A N. 'HR.. 2 INCH F':1 2 1:2 1 Hft.J e. NH P HIL Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm orlomm 31I8 251a 400 11 3/4 3/8 8mm or 10mm 31/ 21/2 400 11 1 3/8 8mm or 10mm 33/s 211a 400 12 1/4 3/8 8mm or 10mm 33/4 21/a 400 13 11/2 3/8 8mm or 10mm 37/6 2/l 400 14 2 3/8 8mm or 10mm 41/ 3 400 15 21/2 3/8 10mm 53/s 41/e 600 27 3 3/8 10mm 51/a 4 600 29 3'/2 3/8 10mm 73/s V/4 600 34 4 3/8 10mm 7 /a 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/,, 6/4 1250 73 8 1/2 12mm 131/ 8/4 1250 136 Main Office/Manufacturing Facility 13Th ¶i:pcit Ay, • 13It3. (f 939/9 • Pli 909 /31 ,b99 • 133 909 /13103.311) . Customer Service • 9,3) /19 www.tolco.com Fig. 98 Rod Stiffener Size Range Secures 3/8 thru 7/8 hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By Figure number Fig. 99 - All Thread Rod Cut to Length res 3/81 thru 7/8" rod in 1" incrTTTnts Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions , Weights Rod Max. Rec. Load Lbs. Size For Service Tomps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/0 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 100 - All Thread Rod Full Lengths Size Range Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish —Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions Weights Max Rec. Load Lbs, Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1/4 8000 7140 360 11/ 11630 10370 510 Main Office/Manufacturing Fact lily 13/s niip;vn Av(,, Como.(A 922/9 • Ph 90 /3/ hhh) Fix 5$ /3,10330 is Customer Service • s)/) 106 1)21b6 wwwtolco,com #\ ri - 19ig1 ikiVJI APPROVED LISTED 8007957 GST 10 X CPVC1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1,5 8008957 GST 20 X 2-1/2 850 1.5 X 4 14-75 1.5 8068925 GST 20 SS X 2-1/2 850 1.5 8010957 GST 30 X 4 1500 1.5 X 4 1475 1.5 8009925 GST 25-380 X 4 1500 1.5 X 4 1475 1.5 8022925 SWG 25-380 X 3-1/2 - 4 1500 1.5 X 4 1475 1.5 8021957 SWG 20 X 2-1/2 - 3** 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SH GST 2O X 3 1050 1,5 X 4 1475 1.5 8141957 SH GST 3O X 4 1500 1.5 X 4 1475 1.5 8140957 SH GST 20 SS X 3 1050 1.5 8142957 SH GST 3OSS X 4 1500 1.5 8038957 DSTR 1 X 4 1500 0.035 X 4 175 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR I X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 8059957 CST 20 X 4 145 3000 PSI 8061957 SWC20 X 4 145 3000 PSI * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" JAL ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" :1 IN. Bu11dex UL and FM tests were performed in compliance with NFPA-13 Standards. WWW.itwbuitdex.com Fastening requirement 5 times weight of water filled schedule 40 pipe plus 250 pounds. 800-284-5339 SSS2S Model V-723 Mechanical Tee I of 3 2 of 3 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-816-1680 Email: techsvcslvikingcorp.com DESCRIPTION VGS° Model V-723 Saddle Let small mechanical tees are available in sizes 1-1I4 through 2-1f2'. The Models V-723 mechanical tees provide an easy take-out of a branch outlet without the need for welding. VGSP Mechanical Tees are manufac- tured at 13/09001 certified facilities an are designed to conform to ASTM and other Standards where applicable. Threads are NPT per ANSI 8120.1. LISTINGS AND APPROVALS Guide No. VIZM <' Class 1920 TECHNICAL DATA Specifications: Maximum wvrking pressure: 300 psi (21 bar) Outride iron conformrtg toASTMA536 Grade 65-45-12 Standard black finish Hot dipped Zinc galvanized versions are available (conforming to ASTM A153); when ordering, add a G suffix to the Model number. Rubber compound EPOM Grade 8 conforming to ASTM D2000. A)MNA C605, NSF 61 and tAPMO. Nuts and Botts: Zinc plated. Carbon Steel conforming toASTM A183 Grade 2 (UNC nuts and bolts are a silver chromate color and ISO are a gold chromate color) 1.25 a 0.0 1.18 1.87 1.63 15.800 I 20-22 09 (32 x15) 1301 (48) (891 (56) (42) 13'9°) (27-30) (0411 l.25x0.75 1.18 187 3.5 2.2 1.63 U-BoO 20-22 1.0 (32020) (30) (48) (89) 1561 )3/BO) (27-30) (0.45) 1.18 2.04 3.5 2.2 1.73 U-Sat 20-25 1.0 (32o 25) (30) (52) (89) (56) 1441 13/00) (27-30) (545) 1.5a0.5 118 3.04 3.5 3.2 1.79 U -Bat 20-22 0.9 (40v 15) (30) (52) (89) (56) (46) (3/So) (27-30) (0.41) 1.5a1L75 118 2.04 3.5 2-2 1.79 U-Bat 20-22 0.9 (40o20) (30) (52) (89) (56) (46) (3/So) 127-301 (5.41) 1.581 1.18 2.04 3.5 2.2 1.69 U-Bat 20-22 0.9 (40v20) (30) (52) (85) 106 (3/8e) (27-30) (0.41) 280.5 1.18 2-30 3.86 2.2 2.07 U-Bat 20-22 0.9 (500IS) (30) 159) (98) (56) (53) (3/Be) (27-30) (5.41) 280.75 1.18 2.30 3.85 2.2 2.07 U-BOO 20-25 0.9 )50a20) 1301 (59) (98) (56) 1531 (3/80) (27-30) (5.41) 2x1 1.18 3.30 3.86 3.2 1.97 U-But 20-25 1.0 (50030) 130) 159) (98) (56) tOol (3/8o) 127-30) (0.45) 2-580.5 1.19 3.46 4.37 2.2 2.25 Li-flat 20-22 1.5 (SOy 151 (35) (63) hill 155) 157) )3/8°) (27-30) (0.45) 2-505.75 1.18 2-46 4.37 22 2.25 U-BoO 20-22 1.0 (65o30) (30) 63) (111) (56) (57) 13/8ot (27-30) (0.45) 2.5a1 1.18 2-46 4.37 2.2 2.13 U-8at 20-22 1.0 (65022) (35) (63) (111) (56) 1541 (3/8o) 1 (27-30) (0.45) H&e dian,eters are 0u89e5t04 hole saw dianwtem. r. Take-out (Costar 05000 end at pipe to be engaged) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs(vikingcorp.com 4. HOLE CUTTING The hole-ad method of pipe preparation is required when using mechanical lees, mechanical crosses, and saddle-lets. The method of pipe preparation requires the catting or drilling of a specified hole size on the centerline of the pipe. Always use the correct hole saw size as shown this data sheet and never use a lords for cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16 mm) of the hole should be inspected to ensure a dean smooth surface, free of any indenta-tions or projections that could affect proper gasket sealing. The area within the W dimension should also be inspected and must be free for dir), scale or any imperfection that could affect proper seating or assembly of the fitting. A n.1le rr:ti1r. Model . Mechanical Tees S. INSTALLATION NOTES: Use a wrench to hold the threaded Table ____________ Saddle _Lets ________________ outlet in place when installing the - Tighten the nuts evenly. K-factor of Saddle-Lets 1(12 1(15 1(15 Do not install sprinkler directly otto Saddle-Let with 1' cadet. Hole Gasket Threaded outlet Nuts Sprinkler Figure 1: V.723 Saddle-Let Installation The latest V0S Technical Dora can be cesed at httpdt*wweilsinggroupincaxm. Scan to visit our Mobile, webster Form No. F_110515 16.12.08 Rev 16.1 Replaces Form No. F_110515 Rev 15.1 Form No. F_110515 16.12.08 Rev 16.1 (Added K-factor limit (able and flow data) 3 of 3 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 289418-1680 Email: techsvcstvikingcorp.com 6. FLOW DATA Flow test data has shown that the total Fornrabs for Ce Wues: head loss between point A and B for = the fittings can be expressed in terms AP of the pressure difference across 0 = Flow (GPM) the inlet and branch. The pressure pre— Drop (pa.) difference can be obtained from the o=c x C0 Flow Coefficient relationship below. B-20 Form No. F_1105.15 16.12.08 Rev 16.1 Replaces Form No. F_110515 Rev 15.1 (Added K-factor limit table and flow data)