Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; ; AS100095; PermitCity of Carlsbad Sprinkler Permit Permit No: AS100095 2525 EL CAM INO Job Address: REAL Permit Type: SPRINK Parcel No: 1563020900 Status: ISSUED Applied 8/2/2010 Approved: 8/2/2010 Lot #: 0 Reference No.: Issued: 8/2/2010 PC #: Inspector: Project Title: SHOE PALACE T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: ARROW AUTOMATIC FIRE SPRINKLER INC 9520 PATHWAY ST SANTEE CA 619-448-2518 Owner: PLAZA CAMINO REAL C/O WESTFIELD PROPERTY TAX DEPT P0 BOX 130940, DEPT WFLD CARLSBAD, CA Fees ($) Add'I Fees ($) Total ($) Balance 130 0 130 0 COVERAGE PER SPRINKLER:130 MAX sq. ft. TYPE OF SPRINKLERS CALCULATED: VIKING UPRIGHTS AND PENDENTS NUMBER OF SPRINKLERS CALCULATED: 18 SPRINKLERS HOSE-STREAM DEMAND: 250 gpm TOTAL WATER REQUIRED (INCLUDING HOSE): 769.9 gpm FLOW AND PRESSURE (AT BASE OF RISER): 519.9 gpm @ 81.7 psi TYPE OF SYSTEM: WET WATER SUPPLY Source: EXISTING CALC INFORMATION Test Date: 8-16-2010 Test By: BP Location: BASE OF RISER (SOURCE) SYSTEM DEMAND: 711.2 GPM 100 PSI @ BASE OF RISER (SOURCE) Source Elevation Relative to Finished Flow Level:+3-0 ft. 10% REDUCTION USED IN CALCULATIONS GPM USED IS FOUND ON SYSTEM 3 CALC. (AS-BUILTS) NAME OF DESIGNER: BRAD PAVLICK AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPT. Calculations performed by HASS under license # 38020412 granted by HRS SYSTEMS, INC. Petersburg, TN 37144 USA. (Notes continue after pipe calculations results.) Items listed in bold print are automatically transfered from the calculation report :j. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 ..............DATE.:. 9/13t2.O.1O.....C.:.\PROGRNFiLES\HRS,,.. SYSTEMS \HASS8..1\SHOEPALACE.T-ELCA1'4.S.DF JOB TITLE: .SHOEPALACE-EL-CAM .. . 0 0 0 0 0 0 • • • • • (_I 0 0 0 0 0 0 I 0 W (\] —Qu)-H--- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 -DATE,:. 9/13/20.10. C:\P.ROGRAN .FILES \.HRS.SYSTENS\HASS.8i\ SHOE PALACE -ELCAN.SDF JOB TITLE: SHOEPALACE_EL-CAIVI . . .. . ,. NFPA WATER SUPPLY DATA . - •. - ..- SOURCE STATIC RESID FLOW AVAIL TOTAL REQ1 D NODE PRESS PRESS @ PRESS @ DEMAND PRESS TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 90 0 85.0. 11 2 711'. 88.8 769 9 81.7 AGGREGATE FLOW ANALYSIS: -- . TOTAL FLOW AT SOURCE 769.9 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 519.9 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 30.0 - - - - 18.2 - - - 2 30.0 - - - - 19.7 3 30.0 - - - - 26.4 4 30.0 - - - - 30.4 5 30.0 - - - - 34.0 6 30.0 - - - - 39.7 7 30.0 - - - - 21.7 - - - 8 30.0 - - - - 23.4 9 30.0 - - - - 25.5 10 30.0 - - - - 29.9 11 30.0 - - - - 33.6 12 30.0 - - - - 39.6 13 30.0 - - - - 19.1 14 30.0 - - - - 20.2 - - - 15 30.0 - - - - 27.0 - - - 16 30.0 - - - - 31.1 - - - 17 30.0 - - - - 34.7 - - - 18 30.0 - - - - 40.6 - - - Hi 24.0 K= 5.60 18.9 24.3 H2 30.0 K= 5.60 18.4 24.0 H3 30.0 K= 5.60 24.6 27.8 H4 30.0 K= 5.60 28.4 29.8 H5 30.0 K= 5.60 31.7 31.5 H6 30.0 K= 5.60 37.1 34.1 H7 22.0 K= 5.60 22.2 26.4 H8 30.0 K= 5.60 21.8 26.2 H9 30.0 K= 5.60 23.7 27.3 RiO 30.0 K= 5.60 27.9 29.6 Hil 30.0 K= 5.60 31.4 31.4 H12 30.0 K= 5.60 37.0 34.1 H13 24.0 K= 5.60 19.2 24.6 H14 30.0 K= 5.60 18.8 24.3 H15 30.0 K= 5.60 25.2 28.1 H16 30.0 K= 5.60 29.0 30.2 H17 30.0 K= 5.60 32.4 31.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS - Page 4 DATE.: .,,..9t13.t2.01.0 \PROGRAN FILES\HRS .SYSTEMS \.HASSa.1\SHOE.PALACE.ELCAN....SD.F ... JOB TITLE: SHOEPALACE-EL-CAM NODE ANALYSIS DATA .. NODE TAG ELEVATION-'-...'NODE TYPE PRESSURE DISCHARGE NOTES (FT) H18 30 0 K= 5 60 37..':9' 34 5 300----............. - --,.,- 6.-6----- --.-,-,, 29.5•-'-- ........ 9;5 ............................... :t:.. C 30.0 ------ 46.7 . •- _.. . . .. . D •. .. 29.5 .. - - - - 49.7 . --...r . E 30.0 ---- . 47.6 --- - .... F.........................................29.5................................................-..-- ................ .--...-...- .................................. ......... ...-- G 29.5 - - - - 64.0 H 29.5 - - - - 68.1 - - - I 29.5 - - - - 69.9 TOR 29.5 - - - - . 70.0 . SOURCE 3.0 SOURCE 81.7 519.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: Owl :91 13/2010,,.,.C.-\. :-PRRANOG .FI.LES\HR S .SYSTEMS \HASS.8.1 \S.HOE.PALACETELCAN. SDF JOB. TITLE: . SHOEPALACE-EL-CAN NFPA PIPE DATA. -- Pipe Tag '- . K-fac':. Add F1AddF1 .9. :. I :H:.L . :0::..: (PtY .F. .rm....NOde ...El.,,(:f.t) .(.q) . Node /..,..:om.ID F. . ,...' . . To Node El (ft) PT Tot (Q) Disch Act ID (ft Pipe-: 1 '5:.-60- 4.bjshi:.......................50120 I06 30.0 - -18.2 0..0 ........ 1.000 2E: 4.0 4.00 2.6 Hi 24...0 18.9 1.049 .10.50. 0.187 2.0 ...........PIpe ....2 60240 Disch- ........ . .....................................0 . SO- ......-1-2....................... 2 30.0 19.7 0.0 1.000 E: 2.0 7.00 0.0 H2 30.0 18.4 24.0 1.049 T: 5.0 7.50 0.182 1.4 Pipe: 3 5.60 27.8 Disch . 0.50 120 1.8 3 30.0 26.4 0.0 . 1.000 E: 2.0 7.00 0.0 H3 30.0 24.6 27.8 1.049 T: 5.0 7.50 0.239 1.8 Pipe: 4 5.60 29.8 Disch 0.50 120 2.0 4 30.0 30.4 0.0 1.000 E: 2.0 7.00 0.0 H4 30.0 28.4 29.8 1.049 T: 5.0 7.50 0.273 2.0 Pipe: 5 5.60 31.5 Disch 0.50 120 2.3 5 30.0 34.0 0.0 1.000 E: 2.0 7.00 0.0 H5 30.0 31.7 31.5 1.049 T: 5.0 7.50 0.302 2.3 Pipe: 6 5.60 34.1 Disch 0.50 120 2.6 6 30.0 39.7 0.0 1.000 E: 2.0 7.00 0.0 H6 30.0 37.1 34.1 1.049 T: 5.0 7.50 0.349 2.6 Pipe: 7 5.60 26.4 Disch 9.50 120 0.5 7 30.0 21.7 0.0 1.000 2E: 4.0 4.00 3.5 H7 22.0 22.2 26.4 1.049 13.50 0.217 2.9 Pipe: 8 5.60 26.2 Disch 0.50 120 1.6 8 30.0 23.4 0.0 1.000 E: 2.0 7.00 0.0 H8 30.0 21.8 26.2 1.049 T: 5.0 7.50 0.214 1.6 Pipe: 9 5.60 27.3 Disch 0.50 120 1.7 9 30.0 25.5 0.0 1.000 E: 2.0 7.00 0.0 H9 30.0 23.7 27.3 1.049 T: 5.0 7.50 0.231 1.7 Pipe: 10 5.60 29.6 Disch 0.50 120 2.0 10 30.0 29.9 0.0 1.000 E: 2.0 7.00 0.0 H10 30.0 27.9 29.6 1.049 T: 5.0 7.50 0.268 2.0 Pipe: 11 5.60 31.4 Disch 0.50 120 2.2 11 30.0 33.6 0.0 1.000 E: 2.0 7.00 0.0 H11 30.0 31.4 31.4 1.049 T: 5.0 7.50 0.299 2.2 Pipe: 12 5.60 34.1 Disch 0.50 120 2.6 12 30.0 39.6 0.0 1.000 E: 2.0 7.00 0.0 H12 30.0 37.0 34.1 1.049 T: 5.0 7.50 0.348 2.6 Pipe: 13 5.60 24.6 Disch 8.75 120 0.2 13 30.0 19.1 0.0 1.000 2E: 4.0 4.00 2.6 H13 24.0 19.2 24.6 1.049 12.75 0.190 2.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 9/l3/,2.010.........0- \.PROGRAN FI.LE.S\HRS SYSTEMS \HAS.581\SBOEPALACE-ELCAN.. SDF.............................. JOB TITLE: SHOEPALACE -.EL-CAM -- Pipe Tag K-fac Add Fl-Add Fl, To Fit L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq Ln F (Fe) To Node El (ft) PT Tot (Q) Disch Act ID (ft ) T Pf/ft (P±) Pipe 14 5 60 24 3 Disch 0" 50 120 l''.4::,. 14 300........................20.2 '1000.......E:-....2.0 ........700...........................................9•0 Hl4-- 30.0 • ia..ã•• 243. 1.049 ..T5.0...........7.50 0.186 Pipe: 15 5.60 28.1 Disch = . 0.50 - 120 1.8 15 - - 30.0 27.0 0.0 1.000 ..E2.0 7.00 0.0 H15 30.0........................25;2 28.1- - --l.049 T:....5.0-........................7...50 0.244................ Pipe: 16 5.60 30.2 Disch 0.50 120 2.1 16 . 30.0 . 31.1 . 0.0 . 1.000 B: 2.0 . 7.00 0.0 H16 30.0 29.0 30.2 1.049 T: 5.0 7.50 0.278 2.1 Pipe: 17 5.60 31.9 Disch 0.50 120 2.3 17 30.0 34.7 0.0 1.000 E: 2.0 7.00 0.0 H17 30.0 32.4 31.9 1.049 T: 5.0 7.50 0.308 2.3 Pipe: 18 5.60 34.5 Disch 0.50 120 2.7 18 30.0 40.6 0.0 1.000 E: 2.0 7.00 0.0 H18 30.0 37.9 34.5 1.049 T: 5.0 7.50 0.356 2.7 Pipe: 19 0.0 0.0 8.00 120 1.5 2 30.0 19.7 24.3 1.000 ---- 0.00 0.0 1 30.0 18.2 24.3 1.049 8.00 0.187 1.5 Pipe: 20 0.0 24.3 1 10.00 120 6.7 3 30.0 26.4 24.0 H2 1.000 ---- 0.00 0.0 2 30.0 19.7 48.3 1.049 10.00 0.666 6.7 Pipe: 21 0.0 48.3 2 10.00 120 4.1 4 30.0 30.4 27.8 H3 1.250 ---- 0.00 0.0 3 30.0 26.4 76.1 1.380 10.00 0.406 4.1 Pipe: 22 0.0 76.1 3 10.00 120 3.5 5 30.0 34.0 29.8 H4 1.500 ---- 0.00 0.0 4 30.0 30.4 105.9 1.610 10.00 0.353 3.5 Pipe: 23 0.0 105.9 4 10.00 120 5.7 6 30.0 39.7 31.5 H5 1.500 ---- 0.00 0.0 5 30.0 34.0 137.5 1.610 10.00 0.572 5.7 Pipe: 24 0.0 137.5 5 17.00 120 6.9 A 30.0 46.6 34.1 H6 2.000 T:10.0 10.00 0.0 6 30.0 39.7 171.6 2.067 27.00 0.255 6.9 Pipe: 25 0.0 0.0 8.00 120 1.7 8 30.0 23.4 26.4 1.000 ---- 0.00 0.0 7 30.0 21.7 26.4 1.049 8.00 0.217 1.7 Pipe: 26 0.0 26.4 7 10.00 120 2.0 9 30.0 25.5 26.2 H8 1.250 ---- 0.00 0.0 8 30.0 23.4 52.5 1.380 10.00 0.204 2.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE.: 9/13/201.0 ..... .C:\PROGRAM -FILES \HRS .SYSTEMS\HASS8.L\SHOEPALACEELCAM...SDF JOB TITLE.: S HOE PALACE. -EL-CA.M . . . Pipe Tag K-fac Add Fl Add Fl To -Fit Frm Node El (ft) PT (qY Node/ Nom ID Eq Ln F (Pe) To Node El (ft) PT Tot (Q) Disch Act ID (ft ) T. Pf/ft (Pf) Pipe: 27 -O.0 52 5 8 ;44 . 3G0- ...................9.J9 ':.273H.9.................................l 250 ---- . ......0.:c,0.: -: ;..,.,,,. 9 300 25.5 ..- .T.1.380 .........__-.1-0. ..00 .0443. ..Pipe: 28 OA - 9. . - - - ....JQ0 120 -- 3,7 1 11 30.0 33.6 29.6 H10 1.500 ---- 0.00 0.0 ......0..................................30.0 ....................299 109.4................................................-1.610 ....................................................1000 0.37-5........................37 Pipe: 29 0.0 109.4 10 10.00 120 6.0 12 30.0 39.6 31.4 H11 1.500 ---- 0.00 .. 0.0 11 30.0 33.6 140.8 1.610 10.00 0.597 6.0 Pipe: 30 0.0 140.8 11 17.00 120 7.1 C ' 30.0 46.7 34.1 H12 2.000 T:10.0 10.00 0.0 12 30.0 39.6 174.8 2.067 27.00 0.264 7.1 Pipe: 31 0.0 0.0 6.00 120 1.1 14 30.0 20.2 24.6 1.000 ---- 0.00 0.0 13 30.0 19.1 24.6 1.049 6.00 0.190 1.1 Pipe: 32 0.0 24.6 13 10.00 120 6.8 15 30.0 27.0 24.3 H14 1.000 0.00 0.0 14 30.0 20.2 48.8 1.049 10.00 0.679 6.8 Pipe: 33 0.0 48.8 14 10.00 120 4.1 16 30.0 31.1 28.1 H15 1.250 ---- 0.00 0.0 15 30.0 27.0 76.9 1.380 10.00 0.414 4.1 Pipe: 34 0.0 76.9 15 10.00 120 3.6 17 30.0 34.7 30.2 H16 1.500 ---- 0.00 0.0 16 30.0 31.1 107.1 1.610 10.00 0.360 3.6 Pipe: 35 0.0 107.1 16 10.00 120 5.8 18 30.0 40.6 31.9 H17 1.500 ---- 0.00 0.0 17 _- 30.0 34.7 139.0 1.610 10.00 0.583 5.8 Pipe: 36 ) 0.0 139.0 17 17.00 120 7.0 E 30.0 47.6 34.5 H18 2.000 T:10.0 10.00 0.0 18 30.0 40.6 173.5 2.067 27.00 0.260 7.0 Pipe: 37 0.0 0.0 0.50 120 2.9 B 29.5 49.5 171.6 6 2.000 T:10.0 10.00 -0.2 A 30.0 46.6 171.6 2.067 10.50 0.255 2.7 Pipe: 38 0.0 0.0 0.50 120 3.0 D 29.5 49.7 174.8 12 2.000 T:10.0 10.00 -0.2 C . 30.0 46.7 174.8 2.067 10.50 0.264 2.8 Pipe: 39 0.0 0.0 0.50 120 2.9 F '29.5 50.5 173.5 18 2.000 T:10.0 10.00 -0.2 E 30.0 47.6 173.5 2.067 10.50 0.260 2.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 ..DATE.: .9113/20.10 C.: \.P.ROGRAM FILES\HRS., SYSTEMS\HASS81\SHOEPALACEELCAN.SDF JOB TITLE: SHOEPALACE-EL-CAN Pipe Tag-.- K-fac Add Fl Add Fl To Fit L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq Ln F (Pe) To: Node El (ft) .PT'-.: Tot (Q) Disch Act ID' (±t....): T. . 'Pf/ft. .'(Pf)' Pipe 40 W-0 171 6 B 8 00 120 0 8 ':• ........174:8 C .............. .3:0,00............. _._ ....................o.Oo .' 'o 29.5- 49•7 -346.4 . . ':. .731..260 ' .'•0Q 0.102 1 0.81, Pipe: 41 ... , 0.0 . 00 . . . 9.00 120 , 0.2 D ' 29.5 49.7 171.6 A '.OUb ---- 0.00 ...0 29.5 4'9"'5....................171.....6 3.260................................ ..... ..........9.00......0.028 ................0;2 Pipe: 42 0.0 346.4 D 33.00 120 13.5 G 29.5 64.0 173.5 E 3.000 B: 9.4 29.57 0.0 F 29.5 50.5 519.9 3.260 T:20.2 62.57 0.216 13.5 Pipe: 43 0.0 0.0 43.50 120 4.1 H 29.5 68.1 519.9 F 4.000 2E:26.3 26.33 0.0 G 29.5 64.0 519.9 4.260 69.83 0.059 4.1 Pipe: 44 0.0 0.0 130.25 120 1.8 I 29.5 69.9 519.9 G 6.000 E:14.0 44.00 0.0 H 29.5 68.1 519.9 6.065 T:30.0 174.25 0.010 1.8 Pipe: 45 0.0 0.0 15.00 120 0.1 TOR 29.5 70.0 519.9 H 8.000 E:19.0 19.01 0.0 I 29.5 69.9 519.9 8.071 34.01 0.003 0.1 Pipe: 46 Source 0.0 26.50 120 11.7 SOURCE 3.0 81.7 519.9 I 8.000 C:47.5 60.20 -11.5. TOR 29.5 70.0 519.9 8.071 B:12.7 86.70 0.003 0.2 NOTES (HASS) Calculations were performed by the HASS 8.1 computer program under license no. 38020412 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.060 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 22.2 ft/sec at pipe 29. -- October 9_2009- - - Sprinkler Jlq -- MICROMATIC®A I. ND .- .- ,- — - The Viking Corporation, 210 N Industrial Park bri,Hsth M(49068- 26..9-945-,9501 Technical Services 877-384-5464 Fax: 269-8181680 Email: techsvcsvikingcorp.com 1. DESCRIPTION . Viking Micromatic® and MicromaticHP® Standard Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K- Factors to meet design requirements. The special Polyester and Teflon® coat- ings can be used in decorative applications where colors are desired. In addi- tion, these coatings have been investigated for installation in corrosive atmos- pheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coat- ings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page hr. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, and 2016 NYC Approved: MEA89-92-E, Volumes 3 and 12 ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificate G4060055, G4980001, G4980003, G4980004, G4980006, and G4980008 LPC Approved: Ref. No. 096e/06 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40137, 0786- CPD-40142, 0786-CPD-40177, and 0786-CPD-40182 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Charts on pages lIt and ilu and Design Criteria on page liv for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1997. Minimum Operating Pressure: 7 psi (0.5 bar)* Viking Technical Data may be found on Maximum Working Pressure: Sprinklers VK02I and VK124 are rated for The Viking Corporation's Web site at use with water working pressures ranging from the minimum 7 psi http:llwwwvikinggroupinc.com. (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- The Web site may include a more recent sure (HP) sprinklers can be identified by locating "250" stamped on edition of this Technical Data Page. the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 C) Overall Length: Refer to the Approval Charts *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0'5 ..bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 10138 and 10193. Copper UNS-C19500 for Sprinklers 10141, 10169, 10174, 10220, 10233, and 12106. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 09995, 10191, 10192, 10218, and 10219): Brass UNS-C36000 Form No. F_080106 Replaces page llq-v, dated March 7, 2008. (Minimum operating pressure for LPCB and CE approval ONLY is 5 psi (0.35 bar). Updated FM Approval for Sprinklers VKIOO and VK145.) 7777 LLI1 TTT'e, Telephone: ... ..Sprinkleri1r ... . ., October 9,2009 MICROMATICOAND NG*-RESPONSE UPRIGHT-*AND CONVENTIONAL SPRINKLER The Viking Corporation,- 210 N Industrial Park Drive*, Hastings MI 49058................................................. Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 .. -. Pip Cap for Sprinklers 09993 and 09995: Brass UNS-C31400 or UNS-C31600 Pip Cap and Insert Assembly for all other Sprinklers: Copper UNS-C11000 and Stainless Steel UNS-530400 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® and MicromaticHP® Standard Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N, Wax Coated = C, Wax Over Polyester = V-NV Temperature Suffix (°F/°C): 135°/68° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, 212°/100" = M, 286°/141° = G, 360°/182° = H, 500°/260° = L, OPEN = Z (Teflon® only). For example, sprinkler VK100 with a 1/2" thread, Brass finish and a 155 °F/68 "C temperature rating = Part No. 101 38A Available Finishes And Temperature Ratings: Refer to Table I Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000) Wrench for wax-coated sprinklers: Part No. 13577W/B** (available since 2006) 'A /" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Micromatic® and MicromaticHP® Standard Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. 0ctober9,2009 .... ... Sprinklerlls ---RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLER . .........Th kiflCoiotión, 210 N...lñdUtriát Park De Hattffi& Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsviking c o r p . c o m TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES F Sp"' MW Spnnkter NominaJ MaxiiiArnbient - Classification - - .- .- Temperalure Rating Cllmg Temperatur& Bulb Color -- Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green Intermediate 212 °F (100 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Extra High 360 °F (182 °C) 300 °F (149 °C) Mauve Ultra High' 500 °F (260 °C) 465 °F (240 °C) Black Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® in all temperature ratings. Wax-Coated Brass and Wax over Polyester-5 for sprinklers with the following temperature ratings: 135 °F (57 °C) Off-White Wax 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 212 °F (100 °C) Dk. Brown Wax6 286 °F (141 °C) Dk. Brown Wax6 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-i 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3Sprinkiers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with norma l o p e r a t i n g t e m p e r a t u r e s a b o v e 300 °F (149 SC). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 ¶ (149 °C ) , response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indi c a t e d o n p a g e s l i t . T h e s e t e s t s cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user th a t t h e c o a t i n g s a r e c o m p a t i b l e with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the expose d e x t e r i o r s u r f a c e s o n l y . N o t e that the spring is exposed on sprinklers with Polyester and Teflon® coatings. For Teflon® coated open sprinklers only , t h e w a t e r w a y i s c o a t e d . 5 Wax Over Polyester is unavailable for Sprinklers VK021 and VK124. 6 Wax melting point is 170 °F (76 °C) for 212 °F (100 °C) and 286 °F (141 °C) temperature rated sprinklers. Protective Sprinkler Wrench Cap El at Figure 1: Standard Sprinkler Wrench 10896W/B rtT TT1AjproaIChi KEY Mrcromatjc and MicromabcHPStandard Response lipnght Sprinklers (pj ble) Maximum 175 PSI (12 bar) WWP * Base 'Thread Size Nominal Overall Listings and Approvals3 Part SI K-Factor Length (Refer also to Design criteria on page llv.) Numberl] P11 BSP U.S. I metric2 Inchesf mm cULus4 FM I NYC6 I VdS I LPCB I (E°I €}" UoightStandard Orifice - 10138 100 /2" 15 mm 5.6 80.6 2-3/16 56 B1,D5,E7,F4 A2, C6, E7, F2, H5 B1,D5,E7 - - - 10233 12" 15 mm 5.6 80.6 16 56 - A2, D3, E7, F2 - 82 B2.j B2 G2 10174 VK145 - 15 mm 56 80.6 ff-3/16 56 - VK100 - 15mm 5.6 80.6 A2, D3, F210193 16 56 81, D5, E7, F4 A2, D3, F2, H5 B1, D5, E7 - - - - Upright-Large Orifice 10220 VK200 112" TiiJ 8.01 115.2 1 2-3/8 11C B1, D5, E7, F4 B2, 06, F2 J BI, D5 B2 I - G4 G4 10141 1 VK200 3/4" 120 mm] 8.0 1 115.2 12-5/161 591 BI, 05, E7, F4 B2, D6, F2 IBI, D5, E71 82]B2, D51 G4 G4 10169 IVK2001 - 20 mm 1 8.01 115.2 12-5/161 591 Bi, D5, E7 82, D6, F2 [__ - 1B2, D5 G4 G4 _Uyright-Small_Orifice' 102189 VKOOI 1/2" 15 mm 2.8 40.3 2-3/16 56 B1,D5,E7 D4,D6 - - - - - 102199 VK002 1/2" 15 mm 42 60.0 2-3/16 56 131,D5,E7 - - - - - - 10191 VK002 - 15 mm 4.2 60.0 2-3/16 56 B1,D5,E7 - - - - - - 101929 VK001 - 15 mm 2.8 40.3 2-3/16 56 B1,05,E7 04,D6 - - - - - 10176 VK002 - 10 mm 4.2 60.0 2-3/16 56 - - - B2 B2,D5 G2 G2 Maximum 250 PSI (17 bar) WWP Upright-Standard Orifice 09993 IVK124I 1/2" 115 mml 5.6 1 80.6 1 2-1/4 I 58 I BI, F5 I - - - - - I - Upright-Small Orifice' 09995IVK02111/2"115rnm1_2.8 I_40.3 1 2-1/4 I_58 I_81 _-_I_-_-_-_-_- Approved Temperature Ratings A- 135°F (57 °C), 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), 212 OF Approved Finishes (100 °C), 286 OF (141 °C) and 360 OF (182 °C) - Brass, Chrome-Enloy, White Polyester6, Black Polyester6, and Black °C), B - 135 OF (57 °C), 155 OF (68 175 OF (79 °C), 200 OF (93 °C), 286 OF (141 °C), and 360 OF (182 °C) 2 - Brass, Chrome-Enloy®, White Polyester, and Black Polyester °F °C) °F °C) °F "C), °F °C) C - 135 (57 155 (68 175 (79 200 (93 and 3 - White Polyester and Wax-Coated Brass (corrosion resistant) OF °C) 212 (100 4 - Brass and Chrome-Enloy6 OF °C), OF °C), °C) 0 - 135 (57 °C), 155 OF (68 175 (79 and 200 OF (93 5 - Wax-Coated Brass and Wax over Polyester6 E - 286 OF (141 6 - Wax-Coated Brass (corrosion resistant) F - 500 OF (260 - 200 OF (93 °C) High-Temperature Wax Coating (corrosion resistant); OF °C), °C), OF G - 155 (68 °C), 175 OF (79 200 OF (93 286 (141 °C), and maximum ambient temperature allowed at ceiling = 150 OF (65 C) 360 OF (182 °C) H - 155°F(68°C) Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Methc K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5cULus Listed as corrosion resistant. 6 Apted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 12. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 OF (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 8 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. The sprinkler orifice is bushed. io( E Certified, Standard EN 12259-1, EC-certificate of conformit 0786-CPD-40137, 0786-CPD-40177, 0832-CPD-2001, and 0832-CPD-2003. 11 0 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. App riçt2 :Temperature- :KEY Micromatic® and MicromahcHP Standard Response Conventiolial pnnkIers J - A1X*-.Esoiicheon (if apphbie) Maximum 175 PS1(12 ba WWP - Base Thread Size Nominal Overall Length Listings and Approvals' Part SIN K-Factor (Refer also to Design Criteria on page lift) Number' - NPTJ BSP U.S. I metric2 Inches I mm cULus4 I FM I NYC' 1VdS I LPCB I (K I Conventional-Standard Orifice 10227 1 VK118 1 1/2° 1 15mm 5.6 1 806 1 2-3/16 1 56 1 Al, B4, C5 - Al, B4, C51 A2 I A2, B4 I A28 0210 101726 1 VK118 I - _15 mm 1 5.6 1 80.6 1 2-3/16 1 56 1 Al, B4, C5 - - - A2, B4 - - Conventinnal-Larqe Orifice 10228 1 VK120 3/4" 1 20mm I .0 115.2 1 2-5/16 59 1 Al, B4, C5 - Al, B4, CS - A2, B4 D38 0210 101686 1 VK120 - 8.0 115.2 2-5/16 59 Al, B4, CS - - - A2, B4 D38 0310 12106 VK120 3/4" 120 mm 20 mm 8.0 1 115.2 1 2-5/16 59 - _- - A2 I - A29 I - Approved Temperature Ratings Approved Finishes A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F 1 Brass, Chrome-EnIoy', White Polyester', Black Polyester', and Black (141 °C), and 360 °F (182 °C) B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 "F (93 "C) 2 - Brass, Chrome-Enloy, White Polyester, and Black Polyester C 286 "F '141 "C' 3 - Brass and Chrome-Enloy® 4-Wax-Coated Brass and Wax over Polyester6 0 - 155 °F'68 "C' 175 °F (79 "C' 200 "F 93 "C' 286 "F 141 "C' " ' " ' " an / d 360°F '182 "C' "F 5 -200 (93 °C) High-Temperature Wax Coating (corrosion resistant); maxi- "F °C) mum ambient temperature allowed at ceiling = 150 (65 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-foctor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion resistant. 6 Sprinklers 10168 and 10172 are available on special order. 7 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 3. aCE Certified Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40142 and 0786-CPD-40 182. 10 0 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 and 0832-MED-1 008. Step 1: Carefully slide the wrench sideways around the deflector, ensuring engagement with the sprinkler wrench flats. Wax Coated _/ Upright Sprinkler Sprinkler Wrench 13577W/BiE* must be used if installing w coated sprin DESIGN CRITERIA (Als 1efer to t1iAjiOaI Charts on pages 11td) cULus Listing Requirements: Micromatic4l and MicromaticHF:10 Standard Response Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Charts for Designed for use in Light, Ocdin% and Extra Hazard occupancies. (Small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers maybe installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized.) to the installation guidelines for old style (conventional) sprinklers. FM Approval Requirements: Micromatie and MicromaticHPe Standard Response Upright Sprinklers are FM Approved as indicated in Approval Chart 1 for installation in accordance with the latest applicable FM Loss Prevention Data Sheets (includig 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling sl o p e and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac-cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. wwA 1/2' ratchet is required Step 2: Carefully press the wrench (not available from Viking). downward and ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 13577W/13 for Wax Coated Sprinklers Form No. F_080106 Replaces page llq-v, dated March 7, 2008. (Minimum operating pressure for LPCB and CE approval ONLY is 5 psi (0.35 bar). Updated FM Approval for Sprinklers VKIOO and VK145.) Bulletin 121 Rev. J 0 IteIiabk Model G4 Concealed Automatic Sprinkler The Concealer® A Concealed Sprinkler With ½" (13mm) or 1½" (38mm) Adjustment Features Cover plate assembly attachment with ½" (13mm) adjustment. Does not require clips or springs. 11/2" (38mm) Total adjustment provided by adjustable inlet versions. Adjustable inlet version available with either 1" NPT male or female threads eliminating costly reducing coupling. Smooth aesthetic ceiling profile. Available in white or other color painted or brass, chrome, or black plated finishes. Ordinary and intermediate temperature ratings. Multiple orifices for design flexibility. Approvals & Listings Underwriters Laboratories Inc. (UL) Underwriters Laboratories of Canada. (ULC) N.Y.C. BS&A No. 587-75-SA. The Concealer® is designed for use where aesthetic ap- pearance is important. Offices, hospitals, motels and restau- rants are but a few of the applications where it can be used. It is available in different orifice sizes allowing the designer to optimize system performance, thereby achieving a most efficient installation. The Concealer® can eliminate the need for precise cutting of drop nipples. The cover plate assembly can be adjusted without tools so it mates accurately with the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Note: Approvals Approvals are for light and ordinary hazard, except for small Product Description orifice sprinklers which are limited to light hazard occupancies. The cup and skirt are fabricated from plated steel and are in- The Reliable Model G4 Concealer® standard response tended for interior non corrosive applications, uses the. proven Model G fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is U.S. Patent No. 4,880,063. recessed into the ceiling and concealed by a flat cover plate. Tk.-. +[, ,,,,-l.-,.-J .-...,-. ,,-4,-,.-. 1/" (1 Q,.,.,,.,..\ .- -,- Application The Reliable Model G4 Conceal- er® is the most versatile concealed sprinkler available. It provides the best form of fire protection while offering an attractive appearance I IIZ>LI IIUU I I9Q9I II IL P1VV uo/ I, hjl 11111) UI L,L)VLI QUI justment. The flat cover plate is attached to the skirt using an ordinary temperature classification solder. This results in a strong cover plate assembly with an ordinary temperature rating, and an intermediate temperature sprinkler which can be installed in 150°F (66°C) environments. When the ceiling temperature rises, the solder holding the cover plate to the and 1/2" (13mm) of cover adjustment for ease of instal- skirt melts, the flat cover plate released thus exposing the lation. The adjustable 1" NPT inlet versions have 11/2" sprinkler inside to the rising ambient temperature. (38mm) of total adjustment and also eliminates. the need The subsequent fusing of the sprinkler element opens the for a reducing coupling. The 1.small diameter cover plate waterway and causes the deflector to drop into position to -. . assembly is easily attached and blends into the ceiling, - distribute the discharging water. Any secure engagement of concealing the most dependable fire protection available, the threads between the cover plate and cup will assure that an automatic sprinkler system the drop-down deflector is properly located below the ceiling - when a sprinkler operates. The Reliable Automatic Sprinkler Co, Inc., 103 Fairview Park Drive Elmsford, NeY'ork 10523 Installation Do not install The Concealer5 in ceilings which have posi- tive pressure in the space in the space above. After a 2/8 inch diameter hole is cut in the ceiling, the sprin- kler is to be installed with the Model G4 Wrench. The wrench has drive tangs which insert into cup slots. When installing a sprinkler the wrench is first positioned into the sprinkler/ cup assembly until the wrench tangs engage drive slots in the top of the cup (there are two sets of mating drive slots in the cup). The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/ cup assembly care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. The adjustable inlet versions are similar to the standard Model G4 except that an addition 1" (25mm) of adjustment is provided by means of a telescoping inlet section that threads in or out of a stationary coupling reducer (either 1 male or 1 female) as shown in Fig. 201 Fig. 3. These sprinklers must be installed before the ceiling is in place, by wrenching on only Temperature Ratings Classification Sprinkler Cover Plate Max. Ambient Temp. Ordinary 135°F157°C 1350F157°C 100°F/380C Ordinary 165°F/74°c 135017157c 100°F138°C Ordinary 165°F/74°C 1650F/740c 100°F138°c Intermediate 212°F/1000C I 165°17/740C 150°F/660c Installation Data the coupling reducer hex flats. After the ceiling has been in- stalled with holes for the sprinkler, each telescoping inlet sec- tion is to be adjusted with the G4 Wrench. Install the cover plate assembly by hand turning it clockwise until it is tight against the ceiling. Maintenance The Model G4 Concealer5 should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper opera- tion or non-operation. Ordering Information Cover Plate Finishes (1) Sprinkler Model Temperature Rating Nominal Orifice Flat Cover Plate Finish Inlet Type Note: Unless otherwise specified, the 165°F (74°C) sprinkler will be provided with the 165°F (740c) cover. Off White Standard Finishes Bronze Chrome Plated White Special Application Finishes Black Plated Bright Brass Black Paint Inlet Adjustment Orifice Sprinkler Total Nominal K Far Thread Approvals Identification Nominal Sprinkler US JIMetric Number (SIN) Non-Adjustable 1/2"(13mm) ½" (15mm) 5.6 80 ½" NPT(IR1/2) 1,2,3 R2115 Non-Adjustable 1/s"(l3mm) 7/i&'(llmm) 4.2 60 ½" NPT(R1/2) 1,2,3 R2113 Non-Adjustable 1/2"(13mm) 3j"(10mm) 2.8 40 1 ½" NPT(R½) 1,2,3 R2111 Adjustable 11/2"(38mm) ½"(lSmm) 5.6 80 1"NPT Male or Female 1,2,3 R2118 Adjustable 11/2"(38mm) 7/16"(llmm) 4.2 60 1"NPT Male or Female 1,2,3 R2113 Adjustable 11/2"(38mm) W' (10mm) 2.8 40 1"NPT Male or Female 1,2,3 R2112 (1) Other colors and finishes are available. Consult factory for details Note: Paint or any other coat- ings applied over the factory finish will void all approvals and warranties. Installation Wrench Model G4 Sprinkler Wrench 1-1g. 1 - Y2" Nl-'l (l-iY2) INO4OjUSt0I Inlet l-l. 2- 1 Nl-'l Male-/Aajustale Inlet Hg. 3 -1' NF-'l 1-emale-Adjustable Inlet The equipment presented in this bulletin is to be installed in accordance with the latest publi s h e d S t a n d a r d s o f t h e N a t i o n a l F i r e P r o t e c t i o n A s s o c i a t i o n , F a c t o r y Mutual Research Corporation, or other similar organizations and also with the provisions of govern m e n t a l c o d e s o r , o r d i n a n c e s w h e n e v e r a p p l i c a b l e . .Productsmanufactured and distributed by.Reliable have been protecting le and property for over 9O'years, and are: installed and serviced by thembOt highly qualified and reputable spnnkler contractors located throughout the United States Canada a n d f o r e i g n c o u n t r i e s Manufactured by - The Reliable Automatic Sprinkler Co., Inc Recycled l (800)431-1588 .Sales Offices. ....... Paper Re-liabie- (914)829.20 J, RéVisiÔ ihes.i.ndi dbtbd le .reliabiesprinkler.com......lnternet, Address, ...................EG.. Printed nu.s.A.o.1o. .... ....... - ....- October 9, 2009 Sprinkler llq The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com 1. DESCRIPTION Viking Micromatic and MicromaticHP® Standard Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers, available in several different finishes, temperature ratings, and K- Factors to meet design requirements. The special Polyester and Teflon5 coat- ings can be used in decorative applications where colors are desired. In addi- tion, these coatings have been investigated for installation in corrosive atmos- pheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon5 and Polyester coat- ings as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions on page hr. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2001, 2002, and 2016 NYC Approved: MEA 89-92-E, Volumes 3 and 12 ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificate G4060055, G4980001, G4980003, G4980004, G4980006, and G4980008 LPC Approved: Ref. No. 096e106 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40137, 0786- CPD-40 142, 0786-CPD-40177, and 0786-CPD-40 182 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request Refer to the Approval Charts on pages lIt and 11u and Design Criteria on page liv for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1997. Minimum Operating Pressure: 7 psi (0.5 bar)* Viking Technical Data may be found on Maximum Working Pressure: Sprinklers VK021 and VK124 are rated for The Viking Corporation's Web site at use with water working pressures ranging from the minimum 7 psi http:llwww.vikinggroupinc.com. (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- The Web site may include a more recent sure (HP) sprinklers can be identified by locating "250" stamped on edition of this Technical Data Page. the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Charts - Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Charts.• *cULus Listing, FM Approval, and NFPA.13 installs require a minimum, of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar) Material. Standards:',..... .... .'-- -" .:. ',. .. ,.,-. ... -.:" .. ,., . '-. '- - ..-.....-,.-, - ,., , - ..- .•'. Frame Casting Brass UNS-C84400 - - Deflector Brass UNS-C23000' or Copper UNS-C19500for Sprinklers 10138 and"10193. Copper UNS-Cl9500-for Sprinklers-- 10141,10169,10174, 10220, 10233, and 12106. Brass UNS7C26000 for all other- Sprinklers.. Bushing (for Spnnklers 09995 10191 10192 10218 and 10219) Brass UNS-C36000 Fbr' No':F:oaol06 ' TRè1 é'1i--dated Ma CE• . F,Mppcyal,fcSprIni,cler,.V.,K.100 and..V.145.L Sprinkler lit October 9, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: te c h s v c s v i k i n g c o r p . c o m Approval Chart I -. Temperature KEY Micromatic and MicromaticHP® Standard Response Upright Sprinklers (it $j$fl applicable) Maximum 175 PSI (12 bar) WWP - Base Thread Size' Nominal j Overall Listings and Approvals' Part SIN J K-Factor Length (Refer also to Design Criteria on page 11v.) Number1 NPTI BSPJU.S. I metric Inches l mm cULus4 FM f NYC6 I VdS I LPCB I ((101 011 Upright-Standard Orifice 10138 VK100 1/2" 15 mm 5.61_80.6 L2-3/16 56jI B1, D5, E7, F4 A2, C6, E7, F2, H5 B1, D5, EJ - - - - 10233 VK145 1/2 115 mm 561 80.6 2-3/161 561 - A2, 03, E7, F2 - JB2 B2, D5 B2 G2 10174 IVK145 - 15 mml 5.61 80.6 2-3/16 1 561 - A2, D3, F2 - -_ B2, D5 - - 10193 VK100 - 15 mm 5.61 80.6 12-3/161 561 BI, 05, E7, F4 A2, D3, F2, H5 B1, D5, E71- - Upright-Large Orifice 10220 VK200 1/2" 115 mm 8.0 115.2 2-3/8 60 B1, 05, E7, F4 B2, D6, F2 BI, 05 fif - ± _.4... 10141 VK200 3/4' 20 mml 8.0 1 115.2 12-5/161 59 1 Bi, 05, E7, F4 I B2, D6, F2 BI, 05, E71 B2 I B2, D51 04 04 10169 IVK2001 - 20 mm 8.0 1 115.2 12-5/161 59 1 Bi, D5, E7 B2, D6, F2 I 1_ 182, 05 04 04 Upright-Small Orifice8 102189 VK001 1/2" 15 mm 2.8 40.3 2-3/16 56 BI, 05, E7 04, 06 - - 102199 VK002 1/2" 15 mm 42 60.0 2-3/16 56 BI, 05, E7 - - - - - - 101919 VK002 - 15 mm 4.2 60.0 2-3/16 56 81, D5, E7 101929 VK001 - 15 mm 2.8 40.3 2-3/16 56 81, 05, E7 D4, 06 - - - - 10176 VK002 - 10 mm 42 60.0 2-3/16 56 - - -- 82 B2, D5 02 02 Maximum 250 PSI (17 bar) WWP Upright-Standard Orifice 09993 VK12411/2" 115 mm 5.6 I 80.6 I 2-1/4 1 58 1 B1, F5 Upright-Small Orifices 099959 IVK021 I 1/2' 115 mml 2.8 I 40.3 I 2-1/4 I 58 I B1 I Approved Temperature Ratings A- 135°F (57 'C), 155°F (68 'C), 175 °F (79 °C), 200 'F (93 °C), 212 'F Approved Finishes 1 - Brass, Chrome-Enloy®, White Polyester5, Black Polyester', and Black B - 135 'F (57 °C) 155 °F(68 °C), 175 °F (79°C), 200 °F (93 °C), 286 °F 'F oF 'C), °F 'C), °F 'C), C - 135 (57°C), 155 68 175 (79 200 (93 and White and Black Polyester Polyester and Wax-Coated Brass (corTosion resistant) - Brass and Chrome-Enloy'8 °F °C) 'F 'C), 'F °C), °C) D - 135 (57 155 (68 175 (79 and 200 °F (93 5 .. Wax-Coated Brass and Wax over Polyester" 'F E 286 '141 6 - Wax-Coated Brass (corrosion resistant) F - 500 'F (260 °c)7 G - 155 °F (68 °C), 175 'F (79 'C), 200 °F (93 'C), 286 °F (141 'C), and -200 . 'F (93 'C) High-Temperature Wax Coating (corrosion resistant); 360 'F (182 'C) maximum ambient temperature allowed at ceiling = 150 F (65 C) H - 155'F(68°C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Methc K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metri c K - f a c t o r s h o w n b y 1 0 . 0 . I This table shows the listings and approvals available at the time of printing. Check with the manufacturer for a n y a d d i t i o n a l a p p r o v a l s . 4Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. - - 5cULus Listed as corrosion resistant. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 12. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with n o r m a l o p e r a t i n g t e m p e r a t u r e s a b o v e 300 'F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is signif i c a n t l y r e d u c e d b e l o w 3 0 0 ' F ( 1 4 9 ,'C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards b e i n g a p p l i e d w i t h h y d r a u l i c a l l y c a l c u l a t e d wet systems only. Exception: 4.2Ksprihkl6rs may be installed on hydraulically calculated dry pipe syst e m s w h e r e p i p i n g i s c o r r o s i o n r e s i s t a n t o r .........................................---.-..- --...-.-.-------- ..................- . -internally galvanized, Thespinkleróriflceisbushèd. -. -. - 11(E Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40137, 0786-CPD-40177, 0832-C P D - 2 0 0 1 , a n d 0 8 3 2 - C P D - 2 0 0 3 . !) MED Certified, Standad EN 12259-1,-EC-certificate of áonformity 0832-MED-1003 and 0832-MED-1008. -. ......... Allan Automatic Sprinkler Corporation of So. Cal. Are Protection Contractor Since 1956 • Over 2 Million Installed 3233 Enterprise Street • Brea, California 92821 • 714.993-9500 • Fox No. 714-993-5708 (A Contractors U<. No. 161782 • NV Contractor's tic. No. 0038328 • UT Contractor's tic. No. 92-251605-5501 September 20, 2010 revised July 13, 2010 Daryl K. James and Associates, Inc. 205 Colina Terrace Vista, CA 92084 Attn: Daryl K. James kitfire(sbcqlobal .net Re: Shoe Palace I Westfield Plaza Camino Real Space No. 265, Carlsbad, CA Plan Check No. CB101133 Dear Daryl: This declaration shall confirm that no High-Pile Storage Occupancy permit is required for the subject space. Their inventory of athletic shoes, a class IV commodity as defined by 2007 California Fire Code (CFC) Chapter 23, Figure 2303.7.4 Mix Commodities (see attached Exhibit "A"). They will be stored on shelves to 12'-0" high, in an area of approximately 1,271 sq.ft. Per 2007 CFC, Table 2306.2 for Class l-IV, non-public accessible areas, Option No. I, if automatic fire sprinkler protection is provided (existing), then Smoke Detection, Building Access, Smoke and Heat removal and Draft Curtains are not required. Shelf storage is limited to maximum 100'x 100' dimension, with 400,000 cubic feet per pile. The existing Mall is protected by an Ordinary Hazard fire sprinkler system. The protection provided by this design from NFPA 13 2002 edition, Table 12.10.1.1 Miscellaneous Storage 12' or less in height, (Table 13.2.1 from 2010 edition) allows for greater than 10'-0" to less than or equal to 12' of Class IV commodity, palletized, bin box, and shelf storage (no racks) per Figure 12.1.10, Curve 3. The 2010 edition limits the maximum ceiling height for this application to 32'-0", but the actual ceiling height is only 15'-O"±. Portable fire extinguishers shall be provided and the area will be designated as NO SMOKING. We respectfully seek your concurrence with the above interpretation of California Fire Code, Chapter 23. Sincerely, ALLAN AUTOMATIC SPRINKLER CORPORATION OF SO. CAL. Fauias C4arctfc JAMES CHARRETTE Vice President / ACCEPTANCE BOX Signature/ / Print Ilarne Date Allan Automatic Sprinkler Corporation of So. Cal, Fire Protection Contractor Since 1956 • Over 2 Million Installed 3233 Enterprise Street • Brea, Colifornla 92821 • 714493.9500 • Fox No. 714-993.5708 CA Contractor's Uc. No. 161782 • NV Contractor's tic. No. 0038328 • UT Contractor's 1k. No. 92-251605-5501 EXHIBIT "A" Men's Size 10 typical; Item Upper Lace Sockliner Stockfit Midsole Sole Carton Total Weight % Plastic Component Leather Cotton 50/50 Cotton Rayon & Synthetic Rubber Nylon Cardboard Commodity Class Ill Class I Ill Class Ill Class IV Group A Class Ill Nike Free Run 75.46 3.5 20.48 133.62 10.4 283.49 526.95 2.0 Nike Free 7.0 71.7 3.2 18.78 147.56 28.5 283.49 553.23 5.2 Lunar Glide 2.0 102.5 4 23.75 102.88 64. 396.88 694.01 9.2 Pegasus 27 117.9 4.5 27.36 1 107.42 61.5 396.88 715.56 8.6 (weights are in grams) Cc: George Mersho - Shoe Palace (neoraem(äshoepaIace.com) Jorge - Quality Choice Construction (bill pualitychoiceconstruction.com) T:\WORK9000\9100\9165-10 Shoe Palace\Carlsbad FD.doc Allan Automatic Sprinkler Corporation of So. Cal, Are Protection Contractor Since 1956 • Over 2 Miillon Installed 3233 Enterprise Street • Brea, California 92821 • 714-993.9500 • Fox No. 714-993-5708 CA Contractor's 1k. No. 161782 • NV Contractor's 1k. No. 0038328 • UT Contractor's 1k. No. 92-251605-5501 July 13, 2010 Daryl K. James and Associates, Inc. 205 Colina Terrace Vista, CA 92084 Attn: Daryl K. James kitfire(sbcglobal. net Re: Shoe Palace I Westfield Plaza Camino Real Space No. 265, Carlsbad, CA Plan Check No. CB101133 Dear Daryl: This declaration shall confirm that no High-Pile Storage Occupancy permit is required for the subject space. Their inventory of athletic shoes, a class IV commodity from 2007 California Fire Code (CFC), Chapter 23, Figure 2303.7.4 Mix Commodities (see attached Exhibit "A"), will be stored on shelves to 8'-0'h, in an area of approximately 1,200 sq.ft. Per 2007 CFC, Table 2306.2 for Class l-IV, non- iib1ic accessible areas, Option No, 1, if automatic fire sprinkler protection is provided (existing), then Smoke Detection, Building Access, Smoke and Heat removal and Draft Curtains are not required. Shelf storage is limited to maximum 100'x 100' dimension, with 400,000 cubic feet per pile. The existing Mall is protected by an Ordinary Hazard fire sprinkler system. The protection provided by this design from NFPA 132002 edition, Table 12.10.1.1 Miscellaneous Storage ...12' or less in height, (Table 13.2.1 from 2010 edition) allows for less than or equal to 10' of Ciass IV commodity ,— palletized, bin box, shelf and rack storage, under an unlimited maximum ceiling height, per Design Curve 3, Figure 12.1.10. Portable fire extinguishers shall be provided and the area will be designated as NO SMOKING. We respectfully seek your concurrence with the above interpretation of California Fire Code, Chapter 23. Sincerely, ALLAN AUTOMATIC SPRINKLER CORPORATION OF SO. CAL. 761cs C4an'cf Ic JAMES CHARRETTE Vice President ACCEPTANCE BOX 01 ft Signatufi' / Print Name Date Allan Automatic Sprinkler Corporation of So. Cal. Fire Protection Contractor Since 1956 • Over 2 Million Installed 3233 Enterprise Street • Brea, CalifornIa 92821 • 714-993-9500 • Fox No. 714-993-5708 CA Contractors tic. No. 161782 • NV Contractor's tic. No. 0038328 • UT Contractors tic. No. 92-2516055501 EXHIBIT "A" Men's Size 10 typical; Item Upper Lace Sockliner Stockfit Midsole Sole Carton Total Weight % Plastic Component Leather Cotton 50/50 Cotton Rayon & Synthetic Rubber Nylon Cardboard Commodity - Class Ill Class Ill Class Ill Class IV Group A Class Ill Nike Free Run 75.46 3.5 20.48 133.62 10.4 283.49 526.95 2.0 Nike Free 7.0 71.7 3,2 18.78 147.56 28.5 283.49 553.23 5.2 Lunar Glide 2.0 102.5 4 23.75 102.88 64. 396.88 694.01 9.2 Pegasus 27 117.9 4.5 27.36 107.42 1 61.5 396.88 1 715.56 1 8.6 (weights are in grams) Cc: George Mersho - Shoe Palace (qeoraem(shoeDalace.com) Jorge - Quality Choice Construction (bilUgualitvchoiceconstruction.com) T:\WORK\ESTIMATE\2010\10-159 Shoe Palace\Carlsbad FD.doc Allan Automatic Sprinkler Corporation of So. Cal, 0000S Fire Protection Contractor Since 1956 • Over 2 Million Installed 3233 Enterprise Street • Brea, CoIiornio 92821 • 714-993-9500 • Fox No. 714-993-5708 CA Contractor's Uc. No. 161782 • NV Contractor's 1k. No. 0038328 • UT Contractor's 1k. No. 92-251605-5501 September 20, 2010 revised July 13, 2010 Daryl K. James and Associates, Inc. 205 Colina Terrace Vista, CA 92084 Attn: Daryl K. James kithre(sbc1lobal. net Re: Shoe Palace I Westfield Plaza Camino Real Space No. 265, Carlsbad, CA Plan Check No. CB101133 Dear Daryl: / This declaration shall confirm that no High-Pile Storage Occupancy permit is required for the subject space. Their inventory of athletic shoes, a class IV commodity as defined by 2007 California Fire Code (CFC), Chapter 23, Figure 2303.7.4 Mix Commodities (see attached Exhibit "A"). They will be stored on shelves to 12'-0" high, in an area of approximately 1,271 sq.ft. Per 2007 CFC, Table 2306.2 for Class I-IV, non-public accessible areas, Option No. 1, if automatic fire sprinkler protection is provided (existing), then Smoke Detection, Building Access, Smoke and Heat removal and Draft Curtains are not required. Shelf storage is limited to maximum 100'x 100' dimension, with 400,000 cubic feet per pile. The existing Mall is protected by an Ordinary Hazard fire sprinkler system. The protection provided by this design from NFPA 132002 edition, Table 12.10.1.1 Miscellaneous Storage 12' or less in height, (Table 13.2.1 from 2010 edition) allows for greater than 10'-0" to less than or equal to 12' of Class IV commodity, palletized, bin box, and shelf storage (no racks) per Figure 12.1.10, Curve 3. The 2010 edition limits the maximum ceiling height for this application to 32-0", but the actual ceiling height is only 15'-O"±. Portable fire extinguishers shall be provided and the area will be designated as NO SMOKING. We respectfully seek your concurrence with the above interpretation of California Fire Code, Chapter 23. Sincerely, ALLAN AUTOMATIC SPRINKLER CORPORATION OF SO. CAL. cpse,c C4.4rrette JAMES CHARRETTE Vice President ACCEPTANCE BOX J)4flL if, JftriCy £9 3C Signat46 U. Print Name Date Allan Automatic Sprinkler Corporation of So. Cal. Are Protection Contractor Since 1956 • Over 2 Million Installed 3233 Enterprise Street • Brea, Colirornia 92821 • 714.993-9500 • Fox No. 714-993-5708 CA Contractor's tic. No. 161782 • NV Contractor's Lic. No. 0038328 • UT Contractor's tic. No. 92.251605-5501 EXHIBIT "A" Men's Size 10 typical; Item Upper Lace Sockliner Stockfit Midsole Sole Carton Total Weight % Plastic Component Leather Cotton 50/50 Cotton Rayon & Synthetic Rubber Nylon Cardboard Commodity Class Ill Class III Class Ill Class IV Group A Class Ill Nike Free Run 75.46 3.5 20.48 133.62 10.4 283.49 526.95 2.0 Nike Free 7.0 71.7 3.2 18.78 147.56 28.5 283.49 553.23 5.2 Lunar Glide 2.0 102.5 4 23.75 102.88 64. 396.88 694.01 9.2 Pegasus 27 117.9 4.5 27.36 107.42 61.5 396.88 715.56 8.6 (weights are in grams) Cc: George Mersho - Shoe Palace (ceorqemshoepalace.com) Jorge - Quality Choice Construction (biIkgualitychoiceconstruction.com) T:\WORK\ESTlMATE\2O1O1O-159 Shoe Palace\Cartsbad FD.doc Allan Automatic Sprinkler Corporation of So. Cal. Are Protection Contractor Since 1956 • Over 2 Million Installed 3233 Enterprise Street • Brea, Colifornia 92821 • 714-993-9500 • Fox No. 714-993-5708 CA Contractor's 1k. No. 161782 • NVContractor's tic. No. 0038328 • UT Contractor's tic. No. 92-251605-5501 July 13, 2010 Daryl K. James and Associates, Inc. 205 Colina Terrace Vista, CA 92084 Attn: Daryl K. James kitfirecsbcqlobaI. net Re: Shoe Palace I Westfield Plaza Camino Real Space No. 265, Carlsbad, CA Plan Check No. C131 01133 Dear Daryl: This declaration shall confirm that no High-Pile Storage Occupancy permit is required for the subject space. Their inventory of athletic shoes, a class IV commodity from 2007 California Fire Code (CFC), Chapter 23, Figure 2303.7.4 Mix Commodities (see attached Exhibit "A"), will be stored on shelves to 8'-0" high, in an area of approximately 1,200 sq.ft. Per 2007 CFC, Table 2306.2 for Class l-IV, non- public accessible areas, Option No. 1, if automatic fire sprinkler protection is provided (existing), then Smoke Detection, Building Access, Smoke and Heat removal and Draft Curtains are not required. Shelf storage is limited to maximum 100' x 100' dimension, with 400,000 cubic feet per pile. The existing Mall is protected by an Ordinary Hazard fire sprinkler system. The protection provided by this design from NFPA 13 2002 edition, Table 12.10.1.1 Miscellaneous Storage ...12' or less in height, (Table 13.2.1 from 2010 edition) allows for less than or equal to 10' of Class IV commodity, palletized, bin box, shelf and rack storage, under an unlimited maximum ceiling height, per Design Curve 3, Figure 12.1.10. Portable fire extinguishers shall be provided and the area will be designated as NO SMOKING. We respectfully seek your concurrence with the above interpretation of California Fire Code, Chapter 23. Sincerely, ALLAN AUTOMATIC SPRINKLER CORPORATION OF SO. CAL. Jameg C4arccttc JAMES CHARRETTE Vice President ACCEPTANCE BOX Signature / Print Name Date