HomeMy WebLinkAbout2200 FARADAY AVE; ; FA050016; Permit10/27/21, 8:55 AM FA050016 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2200 FARADAY AV Permit Type: FALARM Parcel No: 2121203700 Lot #: 0 Reference No.: Permit No: FA050016 Status: ISSUED Applied 3/30/2005 Approved: 4/5/2005 Issued: 4/5/2005 PC #: Inspector: Project Title: ROCK STAR FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: E Q B P-i L L C ATTN: CHAD CARPENTER 800 SILVERADO ST #300 LA JOLLA CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 105 0 105 0 1/1 THERE ARE NO PLANS ASSOCIATED WITH THIS PERMIT 14florNp -fl- FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS ROCK STAR 2200 FARADAY AVENUE CARLSBAD, CA FIRE ALARM SYSTEM ROCK STAR 2200 FARADAY AVENUE CARL55AD CALl OKN IA fl R. ALARM SYSTEM SILL Of MATERIALS NOTIFiER AF F-200 FiRE ALARM CONTROL PANEL CSFM# 71 G5-0026: I G4 NOTIFiER LCD-80 TM REMOTE ANNUNCIATOR CSFM# 7120-0028:15G NOTIFiER NSG- I 2LX INTELLIGENT MANUAL FULL STATION CSFM# 7150-0028:199 NOTIFIER F5F-65 I INTELLIGENT SMOKE DETECTOR W/57 I OLF SASE CSFM# 7271-0026:201 CSFM# 7300-0028:173 NOTIFiER FRM- I RELAY MODULE NOTIFiER FMM- I 01 MONITOR MODULE CSFM# 7300-0028:202 NOTIFIER MR-20 I MODULE CSFM# 7300-1004: I OG WhEELOCI(. AS SERIES hIORNISTROE CSFM# 7125-07-55:131 UI FY OF CARLSBA FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, conditions in correspondence and conformance with a pItheses guIaJns The stamping of not be held to permit U.S. Coast Guard 161.002/23/1 Approved 104-93-E Vol. VI (not for releasing) City of Chicago CLASS 1: 1928E The AFP-200 June 26, 2002 DN-3783•A-105 NOTIFIER @ AFP-200 Analog Fire Panel I Section: Intelligent Fire Alarm Control Panels I GENERAL The AFP-200 is a compact, cost-effective, intelligent fire alarm control with a capacity of 198 individually identified and controlled points and an extensive list of powerful fea- tures. The AFP-200 provides capabilities that exceed most large intelligent systems, at a cost comparable to conven- tional control panels. FEATURES 198 intelligent device capacity (99 analog detectors and 99 monitor/control modules). Style 4, 6, or 7. Overall 301 point capability (198 intelligent points, 4 pro- grammable NAC circuits, 99 programmable relays). Network ready (reference NOTl-FIRE-NET TM and NAM- 232 data sheets for more information). Intelligent features: V Manual sensitivity adjustment. V Day/Night automatic sensitivity adjustment. V Drift compensation (U.S. Patent Pending) meets UL requirements as a calibrated test instrument. V Auto detector test (meets NFPA 72). V Maintenance alert (two separate algorithms). V Pre-alarm (AWACSTM U.S. Patent Pending). V Activate local sounder base on pre-alarm. V LED blink control for sleeping areas. Automatic device type check. Releasing features: Four independent hazards. V Sophisticated cross-zone (three options) V Delay timer and Discharge timers (adjustable). Abort (four options). Optional DAd, with AC fail delay. LCD-80 remote display/control. ACS annunciators (ElA-485), including LDM custom. Printer interface (80-column and 40-column printers). 5.0 A usable regulated output power, plus 6.0 A expander (maximum 8.0 A to panel circuits). 80-character LCD display, backlit. Real-time clock, with European format option. History file with 650-event capacity in nonvolatile memory. Includes non-erasable shadow history. Waterflow or supervisory selection per point. Alarm Verification selection per point, with tally. Walk Test reports two devices set to same address. Positive Alarm Sequence (PAS) Presignal per NFPA 72. Silence inhibit and Auto Silence timer options. March time/temporal/California code for bell circuits. Field-programmable on panel or on PC, with user-defined passwords, plus Autoprogram feature. UL-Listed modem interface allows remote/off-site system integration. NOTI•FIRE• NETTM is a trademark of NOTIFIER, 1994. California State Fire Marshal 7165-0028:164 LISTED CS118 (AFP-200C, S635 AFP-200RC) 3783afp2.wmf L__-- FZM-1 two-wire detector interface provides compatibility with many non-NOTIFIER detectors for retrofit applica- tions (consult factory for latest compatibility listings). Dual-rate charger for up to 90 hours of standby power. Two-Stage option for notification circuits (Canada). Tornado Warning activates different notification circuit code. Non-alarm points for lower priority functions. Remote Silence/Reset/Evacuate via monitor modules. Automatic time control functions, with holiday exceptions. Rapid poll algorithm for manual stations. Responds in <2 seconds. Operates with untwisted, unshielded wire (up to 1,000 ft./ 304.8 m)for retrofit applications (U.S. Patent 5, 210, 523). UL Listed for Fire Signaling per Standard 864 & NFPA 72. UL Listed for Burglary applications per Standard 1076. UL Listed for Releasing Service. Complies with NFPA 12, 12A, 12B, 13, 15, 16, 2001 Standards when installed in accordance with appropriate NFPA standard. FM approved for Agent Release and Preaction/Deluge. MEA and CSFM approved; however, not approved for re- leasing by MEA. Approved for marine applications by U.S. Coast Guard and Lloyd's Register of shipping. NOTIFIER® is an operation of Honeywell This document is not intended to be used for installation purposes. We try to keep our I product information up-to-date and accurate. We cannot cover all specific applications IS09001 or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203)484-7161 FAX: (203) 484-7118 d I I .1 NOTIFIER" 12 Clintonville Road, Northford, Connecticut 06472 011GINFIRING &MAMIFAC1URING Made in the U.S.A. DN-3783 06/26/02 - Page 1 of 4 SYSTEM BLOCK DIAGRAM SLC Intelligent Loop ____ --------rk FS751 F DEVICES Photo FST-751 Thermal ------------------NBG-12LX FMM-1 FCM-1 Fixed IDC IAC EIA -435 99 software zones AFP-200 ..- I RS-232 4 Notification or ACM-8R Release Circuits Relay Control - JCRT-2 . phone lines PRN Series Printer UDACT 3183d1ag.wmf Four standard Notification or Releasing circuits. EIA-232 interface for CRT, printer, or PC computer. EIA-485 locp for LCD or LED annunciators. Full Alpha keyboard for menu-driven programming. ' SLC loop. Up to 198 devices on a single pair of wires. NOTI•FIRE•NET" Optional Network Interface via the NAM-232 ACM/AEM-1 6AT LED Annunciaor tH LDM-32 Custom Graphics 5 ampere regulated power supply. Voltmeter! Ammeter Option. Page 2 of 4 - DN-3783 06/26/02 Slot for optional 12 AH batteries; 18 AH with 1313-17. 80-character backlit Up to 90 hours standby power. LCD display. 4 AWACS TM Advance Warning Addressable Combustion Sensing (U.S. Patent Pending) SMOKE OBSCURATION % per foot ALERT ACTION ALARM Warning at panel Shut off power Evacuate building of possible fire to equipment monitored and call fire department by this detector "EQUIP FLOOR 3 EQUIP RACK 5 FLOOR C 1 3 RACK 5 FLOOR 3 EQUIP RACK 5 1E FIRE D:EPTCALLED ALERT: 0.22% 1.40% 1E ACTION: 0.51% 1.40% 0: 11:25 P 12/25/93 D66 11:36 P 12/25/93 D66 P 12/25/93 D66 • • • . - TIME —> ALERT and ACTION levels are completely adjustable in the field to suit the cleanliness and stability of the environment. ALARM levels are field adjustable to one of three levels within the UL permitted range. ACTION levels latch and may be used to perform control functions. ALERT levels self-restore and may be used to activate a local sounder base before general ALARM evacu- ation. 3% 2% 1% Field Programming —3 Ways AUTO-PROGRAM The AFP-200 identifies all devices that are connect- ed, determines the type of device, and loads default values (general alarm) into nonvolatile memory. This is completed in less than 30 seconds. ON-LINE EDIT While still providing fire protection, the AFP-200 pro- gram may be completely edited from the front key- pad. Menu trees permit easy change of any param- eter without referral to the programming manual. Re- call, increment and edit function speeds entry of al- phanumeric labels. New program check routine catch- es common errors. OFF-LINE PC: VeriFire-200 (included with VeriFire-CD) The complete AFP-200 program may be created in an off-line PC-compaible computer with a Windows®- based utility, then loaded into the AFP-200 ElA-232 port. The program may also be off-loaded to a PC at any time. High-speed data transfer completes upload or download in less than one minute. The PC program may also be used to access remote AFP-200 systems over dial-up phone lines, providing detail status infor- mation and history file search/sort. 3. I. GRAM WAIT F 2. AUTO 2 = POINT 4= MESSAGE FZONES 6=SPL ZONES CHECK 3783v200.jpg ii :r - --_i - - -, it TI -H- --.-i - - - 11.... . ...... .... ....... TJ DN-3783 . 02/19/04 — Page 3 of 4 SPECIFICATIONS Primary input power, 120 VAC, 50/60 Hz, 3.0 A; forAFP-200E: 230 VAC, 50/60 Hz, 1.5 A. Total Internal 24 VDC Power: 5.0 A (total shared power). p1 High-ripple regulated power: 1.5A (suitable for EIA-485 devices, except ACM-8R); 1.0 A maximum standby. V Non-resettable power: 500 mA. V Four-wire smoke detector power: 500 mA. i/ Four built-in notification circuits: NAC Circuit 1: 2.25 A. NAC Circuits 2-4: 2.25 A (shared total). NOTE: with opfionalAPS-6R Power Supply NAC circuits 3 & 4 are expanded to 3.0A (8.0 A total power). Battery charger range: 7 AH - 18 AH. Charge high rate: 29.1 V. Float rate: 27.0 V. Relay contact rating: 2.0 A @ 30 VDC. Cabinet dimensions: 16.125" (40.958 cm) high xl 4.5" (36.83 cm) wide x 5.5" (13.97 cm) deep. SYSTEM CAPACITY Total programmable input/output points: 301 Intelligent detectors: 99 Addressable monitor/control modules: 99 Programmable NAC circuits in panel: 4 Programmable software zones: 99 Programmable remote relay/annunciator points: 99 LCD-80 annunciators per system: 4 ACS annunciators per system: 10 CONTROLS AND INDICATORS 6 LED indicators: AC Power; Fire Alarm; Pre-Ala:m, Super- visory/Security; Alarm Silenced; System Trouble. 21 Membrane Switch Controls: Acknowledge/Step; Silence; Evacuate; System Reset; 12-key Alpha pad; 4 cursor keys; Enter. LCD Display: 80 characters (4 x 20) with long-life LED back- light. Data sheets are available for many of the corn paib.'e prod- ucts listed below. COMPATIBLE INTELLIGENT DEVICES FSI-851: Ion detector, replaces FSI-751. FSI-751: Ion detector. FSP-851: Photo detector, replaces FSI-751. FSP-751: Photo detector. FSP-851T: Photo detector with 135°F(57°C)thermal element, replaces FSP-751 T. FSP-7511: Photo detector with fixed thermal element. FST-851: Thermal detector, 135°F (57°C), replaces FST-751. FST-751: Thermal detector, fixed. FST-851R: Thermal detector, 135°F (57°C) with rate-of-rise, replaces FST-751R. FST-751R: Thermal detector, fixed and rate-of-rise. FST-851H: 190°F (88°C) high-temperature thermal deector. FSH-751: HARSH TM photo detector, requires B7IOHD base, detector replaces HPX-751. HPX-751: HARSH TM photo detector, requires B71OHD base. LPX-751L: VIEW® laser detector. FSD-751PL: Low-flow photo duct detector with housing, re- places FSD-751P. FSD-751P: Duct detector, with housing. FSD-75IRPL: Low-flow photo duct detector with hous ng and relay, replaces FSD-751P. FSD-751RP: Duct detector, with housing and relay. B71OLPBP: Standard flanged base, package of ten. B50IBP: Standard flangeless base, package of ten. NOTE: Remove "BP" suffix for single-pack bases. B7IOHD: Base for FSH-751 (HARSH TM) only. B224RB: Relay base. B224B1: Isolator base. B50IBH: Sounder base. B501 BHT: Sounder base with temporal sounder. Page 4 of 4 - DN-3783 02/19/04 NBG-I2LX: Addressable pull station, visible LED. ISO-X: Isolator module. FMM-1: Monitor module. FMM-101: Monitor module, miniature. FDM-1: Monitor module, dual, two independent Class B circuits. FZM-1: Monitor module, two-wire smoke detectors. FCM-1: Control module. FRM-1: Relay module. FSM-101: Pull station monitor module. XP5-M: Transponder, monitor, 5 addressable Class B circuits. XP5-C: Transponder, control/relay, 5 addressable Class B cir- cuits. XP6-C: Six-circuit supervised control module. XP6-MA: Six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. XP6-R: Six-relay (Form-C) control module. XPIO-M: Ten-input monitor module. XPIQ: Intelligent quad transponder. COMPATIBLE DEVICES, EIA-232 Port PRN Series: 80-column printer. VS4095/52: Printer, 40 column, 24 volts. Mounted in external backbox (order from Keltron, Inc.). CRT-2: Video display terminal. NAM-232: Network Interface Module to NOTI• FIRE- NET°' wire or fiber models. COMPATIBLE DEVICES, RS-485 Port ACS Series: Remote Serial Annunciator/Control systems. LCD-80: Remote LCD display. LDM Series: Remote custom graphic driver modules.. ACM-8R: Remote relay module. Eight Form-C relays. NIB-96: Network Interface Board. RPT-485: Series Repeater, isolator and/or fiber-optic modem. UDACT: Universal Digital Communicator. PRODUCT LINE INFORMATION AFP-200: AFP-200 system. Includes main PC board with dis- play and keypad, backbox and door (gray), hardware and in- struction manual. 120 VAC. AFP-200E: Same as AFP-200, but 230 VAC. AFP-200R: Same as AFP-200, but with red backbox and door. AFP-200RE: Same as AFP-200R, but 230 VAC. AFP-200C: Same as AFP-200, but ULC-approved version. AFP-200RC: Same as AFP-200R, but ULC-approved version. DRAFP200*: Replacement door, gray. DRAFP200R*: Replacement door, red. *Add an "E" to end of part number for 230 VAC labeling. SBB-4X: AFP-200 backbox (no door), gray, for replacement only. SBB-4XR: AFP-200 backbox (no door), red, for replacement only. CAB-AM: Heavy-duty outer enclosure. Required for marine agency approved applications. 4XTM: Plug-in Transmitter Module. Provides municipal box and remote station connection. RTM-8: Plug-in Relay Transmitter Module. Provides eight Form- C relays, plus transmitter. 4XMM: AmmeterNoltmeter. TR-4XG: Gray Trim Ring for semi-flush mounting (TR-4XR for red). DP-AFP200: Full-length dead-front panel (required for Cana- dian applications). PS Series: Batteries. The AFP-200 requires two 12-volt, 7.0 to 18.0 AH batteries. BAT Series: Batteries. The AFP-200 requires two 12-volt, 7.0 to 18.0 AH batteries. APS-6R: 6.0 A expansion supply (requires BB-17). BB-17: Battery box, required for batteries above 12.0 AH, or if APS-6R is used. CHG-120: 120 AH battery charger for use with 25 to 120 AH batteries. 411 Series: Digital Alarm Communicator/Transmitter. VeriFire-CD: Programming kit for PC. Includes a CD with a variety of VeriFireTM programs (including VeriFire-200), cable, and instructions. ROM-AFP200SP: Spanish language kit. Includes software IC, manual, and labels. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No CATEGORY LISTEE: DESIGN: 7165-0028:164 Page 1 of 1 Control Unit (Non High-Rise) Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 Model AFP-200 fire alarm control unit. Local, auxiliary, remote station (PPU), proprietary (PPU) and central station (PPU). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 4XTM RTM-8 DP-AFP200, ADP-4 TR-4XG MMX-1, -101 ISO-X N-ELR CRT-2 VS4095/5 CMX-1 BB-17 AVPS-24, MPS-24A, -24B NAM-232 4XMM INA CAB Series* ABS-4D, ABF-4 AKS-1 MIB-W, -F, -WF Transmitter Module Relay Module Dress Panel Trim Ring Monitor Module Loop Isolator Module EOL Resistors Terminal with Keyboard Printer Control Module Battery Box Power Supply Network Adapter Module Meter Module Intelligent Network Annunciator Enclosure INA Cabinet Annunciator Key Switch Media Interface Board INSTALLATION In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Suitable for central station (PPU) service when used with separately listed compatible DACT. This control unit can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. Refer to manufacturer's Installation Manual for details. Also suitable for releasing service. For releasing application, Models NR-45 battery charger and AVPS-24 power supply shall not be used. Please contact the manufacturer for action. *Rev. 11-02-2002 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test 5\ results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager U.S. Coast Guard 161.002/23/2 (AFP-200) 161.002/27/3 (AFP1010, AM2020) 94/60004 (E2) (AFP-200) 93/60140 (E2) (AFP1010, AM2020) California State Fire Marshal 7120-0028:156 3198IB.jpg LCD-80 with ABF-1B (a NOTIFIER® GENERAL The LCD-80 is an 80-character, backlit LCD display annuncia- tor for the NOTIFIER NFS-640, NFS-3030 (ACS mode only), AM2020, AFP1010, AFC-600, AFP-400, AFP-300, AFP-200, System 5000, and System 500 fire alarm control panels, or the NCA network control annunciator. Up to 32 LCD-80s may be connected onto the two-wire EIA-485 port. The LCD-80 has two basic modes of operation, 'Terminal" and 'ACS" mode. The LCD-80TM shares all the features of the LCD-80, but only utilizes "Terminal" mode, where it mimics the panel display. COMMON FEATURES 80-character backlit Liquid Crystal Display (20 characters x 4 lines). Control switches for System Acknowledge, Signal Silence and System Reset. Time and date display field. Enable Key switch and phone jack options. Can be remotely located up to 6,000 ft. (1828.8 m) from the control panel. Local piezo sounder with alarm/trouble resound. Flush/surface/panel mount option. Optional RPT-485 repeater increases the distance and num- ber of LCD-80s in a system (see RPT-485 data sheet). Optional transmission over fiber optics (see RPT-485 data sheet). ACS MODE When operated in "ACS" mode, the LCD-80 provides a remote or local digital display and printer interface for the System 5000 and System 500. For the NFS-640, NFS-3030, NCA, AM2020, AFP1010, AFC-600, AFP-400, AFP-300, and AFP-200, the LCD-80 provides a vectored annunciation capability. Individual devices/zones can be installer-defined to only display and print at specific locations (E)CAMPLE:A maintenance office receives only non-alarm point activations. These inputs could be sump pump on, high water, backup AHU on, tow temperature in freezer, etc.). Alarm/trouble count. Custom "normal" message. European option: first alarm/last alarm/alarm count. Field-programmable messages from CRT or PC-compatible computer (PK-LCD-80 Programming Kit required). ElA-485 interface: up to 32 per system. Printer output port: EIA-232, compatible with PRN Series printers. Field-programmable messages in nonvolatile memory in two options: 128 points, 40 character labels; or 256 points, 20 character labels. Internal nonvolatile clock for time and date in ACS mode. NFS-640, NFS-3030, AM2020, AFP1010, AFC-600, AFP- 400, and AFP-300 "vectored" printer capability. Can be mounted in a System 5000 cabinet module position. NOTE: The NFS-3030 operates with the LCD-80 in ACS mode only. TERMINAL MODE In 'Terminal" mode, the LCD-80 mimics the NFS-640, NCA, AM2020, AFP1010, AFC-600, AFP-400, AFP-300 and AFP- 200 displays. Up to 32 LCD-80s can annunciate and provide remote reset, acknowledge, and silence of the control panel July 19, 2004 DN-3198 D-120 LCD-80 and LCD-80TM Liquid Crystal Displays Section: Annunciator Control Systems @ u <g> LISTED csioo APPROVED (LCD-80) S635 290-91-E (LCD-80) 289-91-E (LCD-80) 104-93-E Vol. lii (LCD-BOTM) 317-01-E (NFS-640) 345-02-E (LCD-80) 3198I8jpg MOLD FOR STATUS CONTRAST ADJUST F HOLOFOR LAMP TEST GLOBAL ACKNOWLEDGE I SILENCE [II RESET 0 LCD-8OTM from remote locations. The DIA-1010 and DIA-2020 (Display Interface) include a Terminal mode driver port for LCD-80s in Terminal mode. The Terminal mode port is standard on the NFS-640, AFC-600, AFP-400, AFP-300, and AFP-200 main PC/ CPU boards. Displays device type identifiers. Device and zone custom alpha labels. Time/date and Device address. May operate in addition to CRT. No programming necessary. LCD-80 displays time, date, and custom messages received from NFS-640, AM2020, AFPI 010, AFC-600, AFP-400, AFP-300, or AFP-200. NOTE: The NFS-3030 does NOT use LCD-80 in terminal mode, or the LCD-80TM. NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our IS09001 product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All Specifications are subject to change without notice. d a 3M For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ENGINEERING & MANUFACI1JRINC NOTIFIER" 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS Made in the U.S.A. DN-3198• 07/19/04 - Page 1 of 2 NFS-3030, NFS-640, AM2020, AFP1 010, AFC-600, AFP-300/400, AFP-200, System 5000, System 500, or NCA System 5000 with panel-mounted LCD-80 3198dia1.wmf 6,000 ft. (1828.8 m) maximum total wire: length EIA-485 EIA-485 ElA-485 (2 wires) (2 wires) (2 wires) 24 VDC V 24 VDC V 24 VDC (2 wires) (2 wires) (2 wires) EJ E E TO LJL1 TO To L_JLJ PRN LCD-80 PRN LCD-80 PRN LCD-80 PRINTER PRINTER PRINTER ElA-232, 4 wires 50 ft. (15.24 rn) max. The LCD-80 in ACS Mode LCD-80 is 8.25" (20.96 cm) high, 4.375" (11.11 cm) wide, and 1.75" (4.45 cm) deep. Up to 32 LCD-80s may be used on one EIA- 485 circuit. NOTE: Must have sufficient regulated 24 volt power. Certain NOTIFIER systems may have lim- its to the amount of LCD-80s with ACK/STEP, "\ Signal Silence, and Reset switches. ) • LCD-80 mounts with any CHS-4 chassis slot. The LCD-80 may display all System 5000 cir- PRN Printer cults. Alternately, it may display up to 192 AIM- 200 points and two rows of modules. The LCD-80 or LCD.80TM in Terminal Mode 6,000 ft. (1826.8 m) maximum wire length I Terminal Mode between each LCD-80 EIA-485 (2 wires) 24 VDC —-j Ej [11111] (2 wires) L.....1 ________ LCD-80(TM) LCD-80(TM) LCD-80(TM) ElA-232 NFS-640, Terminal Mode ElA485 return (2 wires) Printer Port NCA, AM2020, Up to 32 LCD-30(TM)s may be used in a continu- -- AFP1OIO ous 4-wire loop (verify sufficient 24 VDC available). I \ AFC-600, Each may haveACK/STEP, SIGNAL SILENCE, and AFP-300/400, SYSTEM RESET switches. PRN Printer orAFP-200 Displays all analog, addressable ponts. No programming required for LCD-80(TM)s. RELATED OPTIONS ABF-IDB - The ABF-1DB is a semi-flush-mount backbox for the NOTIFIER LCD-80 Series Annunciator. The ABF-IDB mounts one LCD-80(TM). It includes an attractive smoked-glass door with NOTIFIER keylock. Dimensions, BOX only: 9.938" (25.24 cm) high, 4.625" (11.75 cm) wide, 2.5" (6.35 cm) deep. Dimensions, DOOR only: 10.713" (27.21 cm) high, 6.0" (15.24 cm) wide, 0.75" (1.9 cm) deep. PK-LCD-80 (order VERIF!RE-CD): Off-Line Programming Kit for LCD-80. Allows PC programming messages when LCD-80 is used in the ACS mode. CCM-1: Converter Module. Required for terminal mode opera- tion on olderAM2020s orAFP1010s that do not include the DIA- 2020 or DIA-1010 Display Interfaces. Also required for AM2020 and AFP1 010 systems which require a CRT with keyboard. Uses one ICA4L chassis slot or two CHS-4 chassis slots. See ACS Series (DN-524) or ONYXTIII ACS Series (DN-6862) data sheets for additional information on items below. ABF-1 DB: Semi-flush box with alternative smoked-glass door, any keylock. ADP-4: Annunciator Dress Plate, gray. Allows panel mounting of up to four LCD-80(TM) modules in a CAB-3 Series cabinet. ADP-413: Annunciator Dress Plate, black. Allows pane mounting of up to four LCD-80(TM) modules in a CAB-4 Series cabinet. Page 2 of 2 - DNJ-3198 • 07/19/04 ABF-1 B: Annunciator Flush Box, 9.938" (25.24 cm) high, 4.625" (11.75 cm) wide, and 2.5" (6.35 cm) deep. Order AKS-1B key switch and AFJ-1 B phone jack if desired. Can also be mounted in ABF-213 or ABF-4B annunciator backboxes. ABS-ITB: Deap Surface Backbox (mounts one LCD-80/-80TM). AKS-11B: Key Switch (black) to enable/disable controls when moLnted in A3F or ABS-1 TB. APJ-11B: Annunciator Phone Jack, black. Mounts toABF flush box or ABS-i TB. PRN Series: 30-Column Serial Printer (see PRN data sheet). RPT-485W: EIA-485 Wire Repeater. Increases wire distance between LCD-80s in ACS mode (see RPT-485 data sheet). RPT-485F: EA-485 Fiber-Optics Repeater. Increases distance and converts EIA-485 wire to fiber-optics in ACS mode (see RPT-485 data sheet). LISTING No CATEGORY LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7120-0028:156 Page 1 of 1 Annunciators Notifier, A Pittway Company, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 Model ACS annunciator control system. Refer to listee's data sheet for additional detailed product description and operational considerations. Unit consists of the following modules: ACM-16AT, 16ATY*, 16ATG* ACM32A* 32AY* -32 AG* ACM24AT* ACM48A* AEM24AT*, AEM48A* AEM-1 6AT AEM-32A, ACM-32A AFM-16AT, AFM-32A, AFM-16A ABM-16AT, ABM-32A ABS-1, -2 iB* 2B* iT* -iTB* ABF-i -iD -2,-2D, -4 iB* 213* 413* ABF1DB*, 2DB* ADP-4 AKS-1, -1 B' LCD-80, -80TM LDM-32 LDM-E32 LDM-R32 ACM-8R Control Module Control Module Control Module Control Module Expander Module Control Module Fixed Module Blank Module Enclosures (Surface) Enclosures (Flush) Enclosures (Flush) Dress Panel Key Switch Control Panel Lamp Driver Module Lamp Driver Expander Lamp Driver Expander (Relay) Mappable Relay Control Module INSTALLATION MARKING APPROVAL: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as an annunciator system when used in conjunction with separately listed compatible fire alarm control units. *Rev. 1-7-2002 s.I.. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager August 23, 2004 DN-6726' H-240 ©NOTIFIER® GENERAL The NOTIFIER NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull sta- tion that includes an addressable interface for any NOTIFIER intelligent control panel. Because the NBG- 12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. FEATURES Maintenance personnel can open station without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTI- VATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.1 mm2 wire). Semi-flush, mounts to a standard single-gang (2.125" [5.3975 cm] minimum depth), double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Within ADA 5 lb. pull force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on classic protocol systems. Up to 159 NBG-12LX stations per loop on FlashScan® protocol systems. Dual-color LED blinks green to indicate normal on FlashScan® systems. CONSTRUCTION Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the FlashScan® is registered trademark of NOTIFIER. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. NBG-12LX Addressable Manual Pull Station with FlashScan® Section: Intelligent/Addressable Devices Patented, U.S. Patent No. D428,351; 6,380,846 U.S. Patent Pending: 09/686,286 c®US California l/I EA State Fire _ Marshal 67-02-E 7150-0028:199 LISTED S692 U.S. Coast Guard TYPE 161.002/23/3 93/60141 (E3) (AFP-200) APPROVED APPROVED 02/6007 The NBG-12LX Addressable Manual Pull Station bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; closing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow ad- dress settings (1 - 159 on FlashScan® systems, I - 99 on CLIP systems). NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications IS09001 or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203)484-7161 FAX: (203)484-7118 cIruuNc & MANUFRCIURING NOTIFIER 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6726 • 08/23/04 - Page 1 of 2 PRODUCT LINE INFORMATION NBG-I2LX Dual-action addressable pull station. Includes key locking feature. SB-10 Surface backbox. SB-1/0 Indoor/outdoor surface backbox. BG-TR Optional trim ring. INSTALLATION The NBG-I2LX will mount semi-flush into a single-gang, double-gang, or standard 4' (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O surface backbox. If the NBG-12LX is being semi- flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mount- ing with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). SLC (-) SLC (+) ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 375 pA. ARCHITECTURAL! ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-coded, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycar- bonate equivalent) with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-I 0; or semi-flush mount- ing on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual sta- tions shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Detail of BREAKAWAY TAB* Back of station without door. LED )TARY DECIMAL SWITCHES *Remove tab to select addresses above 99 (FlashScan® systems only). Cover open to show easy access to miniature monitor module, rotary switch, and UL labeL Page 2 of 2 — DNJ-6726 • 08/23/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-6302 FAX (203) 484-7309 DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG- 12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-I2LWP, NBG- 12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG- 12SP, and NOT-BG12LX fire alarm pull boxes. *All units except Model NBG-125 are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12L0, NBC- 12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB- I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. *Rev. 02-22-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or , recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: FEBRUARY 22, 2005 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager (0 NOTIFIER® GENERAL NOTIFIER 851 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conven- tional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with decade address switches, providing ex- act detector locations for selective maintenance when cham- ber contamination reaches an unacceptable level. The FSP- 851 photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP-8511. FSP-851 and FSP-851T detectors are compatible with all NOTIFIER intelligent Fire Alarm Control Panels (FACP5). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly en- hances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices com- municate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. FEATURES Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. ° FlashScan®(NFS-640, NFS-3030,AFC-600) and classic CLIP system (AFP-1 00, AFP-200, AFP-300,AFP-400, AFC-600, NFS- 640, AFP1010, AM2020, and NFS-3030) compatible. Rotary, decimal addressing (1 - 99 on current classic sys- tems, 1 - 159 on FlashScan® systems). ° Optional remote, single-gang LED accessory (RA400Z). Dual LED design provides 360° viewing angle. Visible bicolor LEDs blink green every time the detector is addressed, and illuminate steady red on alarm. Remote test feature from the panel. ° Walk test with address display (an address of 121 will blink the detector LED: 12-(pause)-1) (FlashScan® systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white Bayblend®, designed to commer- cial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, or sounder bases. ° Listed to UL 268. Backward-compatible. SPECIFICATIONS Size: 2.1" (5.3 cm) high x 4.1" (10.4 cm) diameter installed in B501 base, 6.1" (15.5 cm) diameter installed in B71OLP base. Shipping weight: 5.2 oz. (147 g). August 23, 2004 DN-6935• H-202 FSP-851 and FSP-851T Intelligent Plug-in Photoelectric Smoke Detectors with FlashScan® Section: Intelligent/Addressable Devices &MEA 225-02-E LISTED C5915 APPROVED S1115 FSP-851TA) '... State Fire Marshal (FSP-851A, California MARYLAND State Fire Marshal 7272-0028:206 Permit #2122 BSMI U.S. Coast Guard C1313066760036 161.002/23/3 (AFP-200) 161.002/27/3 (AFPI010IAM2020) 161.002/42/1 (NFS-640) 03/60011 6934p5o1.jpg FSP-851 with B7IOLP base 1 6935pho1.jpg • FSP-851T with \ B7IOLP base ' Operating temperature: FSP-851: 0°C to 49°C (32°F to 120°F); FSP-851T 0°C to 38°C (32°F to 100°F). Low-temperature sig- nal for FSP-851T at 45°F +1— 10°F (7.22°C +1— 5.54°C). UL-Listed velocity range: 0 —4000 ft/mm. (1219.2 mlmin.), suitable for installation in ducts. Relative humidity: 10% - 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING and APPLICATIONS: NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceilings, space detectors 30 feet (9.144 m) for ceiling heights 10 feet (3.048 m) and higher. For specific information regarding detector spacing, placement, and special applications, refer to NFPA 72. System Smoke DetectorAppllcation Guide, document A05-1003, is avail- able at systemsensor.com. FSP-851 and FSP-851T are Listed for use in ducts, but they are NOT Listed for use inside duct smoke detector housings. See Duct Application Smoke Detectors Guide, document A05- 1004, available at systemsensor.com, for details on pendant- mount applications. FlashScan® is a registered trademark of NOTIFIER. Bayblend® is a registered trademark of Bayer Corporation. NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. I I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ENGINEERING & MANUFACTURING NOTIFIER" 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6935 08/23/04 - Page 1 of 2 ELECTRICAL SPECIFICATIONS: Voltage range: 15 -32 volts DC peak. Standby current (max. avg.): 250 pA @ 24 VDC (with no com- munication enabled); 360 pA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @ 24 VDC ("ON"). BASES AVAILABLE: B7IOLP: 6.1" (15.5 cm) diameter. B501: 4.1" (10.4 cm) diameter. B501 BH or B501 BHT: Sounder base assembly. Includes B501 base. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resis- tive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2" (15.748 cm)x 1.2" (3.048 cm). B224B1 Isolator Base: Dimensions: 6.2' (15.748 cm) x 1.2" (3.048 cm). Maximum: 25 devices between isolator bases. INSTALLATION FSP-851 plug-in detectors use a separate base to simplify in- stallation, service, and maintenance.A special tool allows main- tenance personnel to plug in and remove detectors without us- ing a ladder. Mount base on an electrical backbox which is at least 1.5" (3.81 cm) deep. Suitable mounting base boxes include: 4.0" (10.16 cm) square box. 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. Single-gang box (except relay or isolator base). With B50IBH or B50IBHT base, use a 4.0" (10.16 cm) square box. With B224RB orB224BI base, use a 3.5" (8.89 cm)octago- nal box, or a 4.0" (10.16 cm) octagonal or square box. NOTES: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps' or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult data sheet DN-2243 (ISO-X) for device limitations between isolatormodules and isola- tor bases. PRODUCT LINE INFORMATION NOTE: "A' suffix indicates ULC Listed model. FSP-851: Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A: Same as FSP-851 but with ULC Listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC Listing. Bases: B7IOLPBP: Standard U.S. low-profile base, pkg. of 10. B7IOLPA: Standard U.S. low-profile base, ULC Listing. B501 BP: Standard European flangeless base, pkg. of 10. B50IA: Standard European flangeless base, ULC Listing. B50IBH(A): Sounder base, includes B501(A) base above. B50IBHT(A): Same as B501BH(A), but includes temporal sounder. B224RB(A): Intelligent relay base. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. Accessories: FIIO: Retrofit replacement flange for BX-501 base. Converts BX-501 base for use with FlashScan® detectors. RA400Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. Supported by B7I0LP(A) and B501(A) bases only. SMK400: Surface mounting kit provides for entry of surface wiring conduit. For use with B501(A) base only. RMK400: Recessed mounting kit. For use with B501(A) base only. SMB600: Surface mounting kit for use with B71OLP(A). BCK-200B: Black detector covers, box of 10. M02-04-01: Test magnet. M02-09-00: Test magnet with telescope stick. XR213: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. T55-127-000: Detector removal tool without pole. XP-4: Extension pole for XR213. Comes in three 5-ft. sections. Detector Guards: NOTE: Some guards fisted below may not be applicable to FSP models. SDG-773: Smoke detector guard; cover is 7.0" (17.78 cm) square x 3.0" (7.62 cm) deep. This guard is mechanically com- patible with FSP-751. It is UL-compatibility listed with the FSP- 851 (file UL S5515). STI 9601: Low-profile, flush-mount smoke detector guard, wire.* STI 9602: Low-profile, surface-mount, smoke detector guard, wire.* STI 9609: High-profile, flush-mount, smoke detector guard, wire.* STI 9605: High-profile, surface-mount, smoke detector guard, wire.* STI 9604: Flush-mount heat detector guard, wire.* STI 9610: Surface-mount heat detector guard, wire.* *For dimensions and additional information on STI Steel Web Stop- pers, see data sheet DN-4936. STI-8200-SS: Flush-mount stainless steel smoke detector guard (compatibility pending). STI-8230-SS: Surface-mount stainless steel smoke detector guard (compatibility pending). REMOTE ANNUNCIATOR WIRING DIAGRAM 68332ddr.wmf ri address dial on back of detector Page 2 of 2 - DN-6935 • 08/23/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: 7271-0028:201 Page 1 of 1 Ionization Smoke Detector Notifier, One Fire-Lite Place, Northford, CT 06472 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 Model FSl-751 and *FSI 851 ionization smoke detector. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, model number, electrical rating and UL label. APPROVAL: Listed as an ionization smoke detectors for use with listee's listed Models BX501, B61OLP, B612LP, B614LP, B616LP or B71OLP bases (CSFM Listing No. 7300-0028:173) and separately listed compatible fire alarm control units. *Model FSI-751 is suitable for open area protection at air velocities up to 500 fpm. *Model FSl-851 is suitable for open area protection at air velocities up to 1200 fpm. *Rev. 11-24-2002 JEW s.'.. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or .. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: APPROVAL: XLF: 7300-0028:173 Page 1 of 1 Misc. Devices/Control Unit Accessories Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 Models BX501, B61OLP, 13612LP, B614LP, B616LP and B71OLP detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, product designation, electrical rating and UL label. Listed as detector bases for use with separately listed compatible detectors. 7300-1209:128 07-29-94 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager April 5, 2004 DN-6724 H-230 FCM and FRM Series NOTIFIER® Control and Relay Modules with FlashScan® Section: Intelligent/Addressable Devices GENERAL FCM-1 Control Module - The FCM-1 Addressable Control Module provides NOTIFIER intelligent control pan- els a circuit for Notification Appliances (horns, strobes, speak- ers, etc.) or to monitor a telephone circuit. Addressability al- lows the FCM to be activated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1 Relay Module - The FRM-1 Addressable Re- lay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, damp- ers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FEATURES Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM module requires power (for horns, strobes, etc.), audio (for speakers), or a telephone riser (for hand- sets). Internal relay feature available on FlashScan® sys- tems only. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM may be used to switch 24-volt NAC power, au- dio (up to 70.7 VRMS) or telephone. Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan®, 01 - 99 on traditional systems. Speaker, audible/visual, and telephone applications may be wired for Class B or A (Style Y or Z). APPLICATIONS The FCM is used to switch 24 VDC audible/visual power, high-level audio (speakers), or control telephone devices. The FlashScan® is a registered trademark of NOTIFIER. Noryl® is a registered trademark of GE Plastics, a subsidiary of General Elec- tric Company. California State Fire Marshal 7300-0028:202 LISTED CS669 S3705 MARYLAND IVIEA State Fire Marshal FM Permit #2020 < > 457-99-E APPROVED (See wiring diagram Fig. 5 for FRM-1) FRM may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four- wire smoke detector power. CONSTRUCTION The face plate is made of off-white Noryl®. Controls include two rotary switches for direct-dial entry of address (01-159). The FCM is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM provides two Form-C dry contacts that switch together. OPERATION Each FCM or FRM uses one of 159 possible module ad- dresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or IS09001 anticipate all requirements. All specifications are subject to change without notice. 933I=! .1 For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ENCIrJEEaIrIG & MANUFACTURING NOTIFIER' 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6724 • 04/05/04 - Page 1 of 4 (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM will discon- nect the supervision and connect the external power supply in the proper polarity across the load device. The disconnec- tion of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the communica- tion loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the control panel, so as to differentiate between a module and a sensor address. SPECIFICATIONS for FCM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll (CLIP mode), 375 pA group poll (FlashScan® mode) with LED flashing. External supply voltage (between Terminals T3 and T4): maximum 80 volts (RMS or DC). Drain on external supply: 2 mA maximum (using internal EOL relay). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. RELAY CONTACT RATINGS for both FCM and FRM models Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (LIR = 5 ms) Coded 30 VDC 0.5 A Inductive (LIR = 2 ms) Coded 30 VDC 1.0 A Inductive (PF = 0.35) 1Non-Coded 1125 VAC 1 0.5 A PRODUCT LINE INFORMATION 6724rate.th1 FCM-1 Intelligent Addressable Control Module. FRM-1 Intelligent Addressable Relay Module. A2143-20 Capacitor, required for Class A (Style Z) opera- tion of speakers. SMB500 Optional Surface-Mount Backbox. CB500 Control Module Barrier - required by UL for separating power-limited and non-power limited wiring in the same junction box as FCM-1. WE SPECIFICATIONS for FRM Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (FlashScan® mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2125" (53.975 mm) deep box. EED MOUNTING DIAGRAMS Note CB500 Module Barrier, which creates isolated quadrant. ISOLATED QUADRANT Page 2 of 4 - DNJ-6724• 04/05/04 _...71 01 _______________ CAUTION DE-ENERGIZE UNIT PRIOR TO SERVICING - ..............: The Face Plate Y WIRING DIAGRAMS The following wiring diagrams are provided: FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. FCM-1: Typical fault-tolerant notification appliance circuit con- figuration, NFPA Style Z. FCM-1: Typical wiring for speaker supervision and switching, NFPA Style Y. FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. FRM-1: Relay module wiring diagram. V Fig. I FCM-1: Typical notification appliance circuit configuration, NFPA Style Y. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Communication Line 32 VDC max. Module polarities are shown in alarm. () \ Refer to panel documentation for TO Next \t\ype of cable required. FROM Panel Device (~) or Previous ,LCONTROL Device MODULE 7DO DC Circuit 47K EOL NOTLOOPwire 0 n terminals 3 & 4. Resistor ':1 reak wire to provide ELR47K . 1:. . (+) supervision of connections. '_. 7 - 2 ... (-) ,'J6 (+) 24 VDC 5 ONES ADDRESS POWER SUPPLY (+) (+) Power Supply: Isolated, regulated, UL listed power-limited EOL Relay TO NEXT control module or EOL Relay. per NFPA 70 shown ONE RELAY REQUIRED for each circuit. Listed for fire protection energized Some control panels have the RELAY BUILT IN with battery backup, 24 VDC coil and do not require external wiring. A77-716B Refer to the NOTIFIER manual. V Fig. 2 FCM-1: Typical fault-tolerant notification appliance circuit configuration, NFPA Style Z. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Communication Line 32 VDC max. Module polarities are shown in alarm. \ Refer to panel documentation for TO Next \ype of cable required. FROM Panel Device (+) or Previous _C CONTROL \ Device EOL Resistor ç' MODULEis internal at 24 VDC Circuit terminals 8 & 9 .. / DO NOT LOOP wire E' 9 o'i / on terminals 3 & 4. (-) Break wire to provide (+) supervision of connections. 7 2 i 0 SUPPLY (_) 6 3 24 VDC 'LOOP NES ADDRE SS 'I W (+) N 00 Power Supply: Isolated, regulated, UL listed power-limited EOL Relay . TO NEXT control module or EOL Relay. per NFPA 70 shown • ONE RELAY REQUIRED for each circuit. • Listed for fire protection energized • Some control panels have the RELAY BUILT IN with battery backup. 24 VDC coil and do not require external wiring. A77-7168 Refer to the NOTIFIER manual. DN-6724 • 04/05/04 - Page 3 of 4 Fig. 3 FCM-1: Typical wiring for speaker supervision and switching, NFPA Style Y Connect modules to Listed compatible Refertc panel documentation NOTIFIER control panels only. Communication Line for type cf cable required. TO Next ----,---' All wiring shown is supervised. D-.vice 32VDC max. / FROM Panel or Previous Wires must be supervised per NFPA. CONTROL .TL_ 7 ' / Device Module polarities are shown in alarm. '7 MODULE Audio Circuit • U / DO NOT LOOP wire • i / on terminals 3 & 4. 47K EOL Resistor Ej 8 1 7 TENS 2. -) J Break wire to ensure supervision of connections. ELR47K (—) (—) ( 3). C—) . AUDIO AMPLIFIER • J 0 ; '. 70.7VRMS max. LOOP ADOSESS — Use only models AA-30, q 0 r-1 AA-1OOor AA- 12O. (+) . (+) Amplifier must provide I wiring supervision per NFPA. Speaker Switching Circuit: NFPA STYLE W TO x Con",4odule SUPERVISION Speakers must be listed for fire protection. Last module must return I Refer to the Relay Contact Rating table for maximum load, wires for supervision. -i 6724wir3.wm/ 'V Fig. 4 FCM-1: Typical fault-tolerant wiring for speaker supervision and switching, NFPA Style Z. Connect modules to Listed compatible NOTIFIER control panels only. All wiring shown is supervised. Refer to panel documentation Wires must be supervised per NFPA. Communication Line for type cf cable required. Module polarities are shown in alarm. TONf (et Dcxcxcxm-..\ 32 VDC max. (—) FROM Panel or Previous ciDOL ONTROL Device EOL Resistor is internal a terminals 8& 9. pf, MODULE Audio Circuit Bypass Capacitors: A2143-20, 100 0 16 V, non-polarized, < 10 pA leakage. DO NOT LOOP wire ME 9 0: Break wire to ensure 301 AUDIO AMPLIFIER 19P ADO 70.7 VRMS Max. '_LL RT ONES 09i Use only models AA-30, wiring supervision per NFPA. Speaker Switching Circuit: NFPA STYLE X TO ext Control Module j H SUPERVISION Speakers must be listed for fire protection. Last module must return I 6724 •4 Refer to the Relay Contact Rating table for maximum load, wires for supervision. -i NOTE regarding AUDIO AMPLIFIER in Figures 3 & 4 above: 1) Audio circuit wiring must be twisted-pair as a minimum. See NOTIFIER installation manual for detailod information. TO Next FROM Panel W or Previous Device / / ' '\•.,' ' Device - - - MODULE VDC maximum. ) documentation for type of cable required. RELAY COMMON 2 9 oE NORMALLY CLOSED 2 81 (+) 4 Fig 5 NORMALLY OPEN 2 7H 2 RELAY COMMON 1 6 I FRM-1 Relay module NORMALLY CLOSED 1 [[[5 '-*--U-4 NORMALLY OPEN 1 wiring diagram r Connect modules to Listed 1 LOOP ADDRESS I • • • • compatible NOTIFIES control, • panels only. • • Module does NOT supervise 6724wr5wmt controlled circuits. Page 4 of 4 - DN-6724• 04/05/04 (a NOTIFIER® August 23, 2004 DN-6720 H-220 FMM-1, FMM-101, FZM-1, FDM-1 Monitor Modules with FlashScan® Section: Intelligent/Addressable Devices GENERAL Four different monitor modules are available for NOTIFIER in- telligent controls to suit a variety of applications. Monitor mod- ules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1). FMM-1 - is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input de- vices. FMM-101 - is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to supervise a Class B (Style B) circuit. Its compact design allows the FMM-101 to often be mounted in a single-gang box behind the device it's monitoring. FZM-1 - is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. FDM-1 - is a standard-sized dual monitor module used to monitor and supervise two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a new communi- cation protocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between ana- log intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FlashScan® is a registered trademark of NOTIFIER. FMM-1 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan® sys- tems, 01 - 99 on CLIP systems. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1 Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 can be used to replace MMX-1 mod- ules in existing systems. @ u < > LISTED CS669 APPROVED S635 9 U.S. Coast Guard 161.002/23/3 (AFP-200: FMM-1/-101, FZM-1) 161.002/42/1 California State Fire (NFS-640: FMM-1/-101) Marshal 7300-0028:202 detail of FDM-I - note "ones" addresses are 0, 2, 4, 6, 8 only 678910 0 1 7 TENS 8 101514 2 5 2'' 4 ONES 0 Ht12 03 06 ltoo I ADDRESS FMM-1 Applications - Use to monitor a zone of four- wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact alarm activation devices. May also be used to monitor normally- open supervisory devices with special supervisory indica- tion at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for su- pervision of the Style 0 circuit. Maximum IDC loop length is 2,500 ft./762 m (20 ohms maximum). 93/60141 (E3) (FMM-1/-101, FZM-1) 941600041E2 (AFP200: except FDM-1) 02/60007 (NFS-640: FDM-1) MEA 143-01-E (FDM-1) 317-01-E (FMM-1/-101) 345-02-E (FMM-1/-101) 457-99-E (FZM-1, FMM-1/-101) 447-99-E FMM-1 and FZM- I NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our IS09001 product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118 ENGINEERING & MANUFACTURING NOTIFIER" 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS DN-6720• 08/23/04 - Page 1 of 6 FMM-1 Operation - Each FMM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FMM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 375 pA (LED flashing). EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FMM-101 MINI MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the panel. Powered directly by two-wire FACP. No additonal power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01— 159 on FlashScan®sys- tems, 01 - 99 on CLIP systems. 15 0 1 ADDRESS , 0 - /ZIOZ 0 13 Ve/ I_____ TENS ONES 1_I Hi.... Lu co J Li U U U The FMM-101 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101 is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101 can be used to replace MMX-101 module in existing systems. FMM-101 Applications - Use to monitor a single de- vice or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry- contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47 ohm End-of- Line Resistor (provided) terminates the circuit. FMM-1 01 Operation - Each FMM-1 01 uses one of 159 available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). FMM-101 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.5" (1.270 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. ° SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan® sys- tems, 01 - 99 on CLIP systems. LED flashes during normal operation (this is a program- mable option). LED latches steady to indicate alarm on command from control panel. The FZM-1 Interlace Module is intended for use in intelk gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional de- tectors back to the control panel. All two-wire detectors be- ing monitored must be UL compatible with the module. The FZM-1 has a panel-controlled LED indicator and can be used to replace MMX-2 modules in existing systems. FZM-1 Applications - Use the FZM-1 to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Ini- tiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (pro- vided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1 Operation - Each FZM-1 uses one of 159 avail- able module addresses on an SLC loop. It responds to regu- lar polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communica- tion with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). FZM-1 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum operating current: 255 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VRMS maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2 of 6 - DN-6720 • 08/23/04 /AiWöNTY Avoid duplicating addresses on the system. Face Plate for FMM-1, FZM-1, and FDM-1 MOUNTING DIAGRAMS for standard-sized modules I it' FDM-1 DUAL MONITOR MODULE The FDM-1 Dual Monitor Module is intended for use in in- telligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecu- tive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or normally closed security devices. The module has a single panel-controlled LED. NOTE: The FDM-1 provides two Class B (Style IDC circuits ONLY. Class A (Style Z) IDC circuits are NOT supported in any application. FDM-1 Specifications Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 5.7 mA (LED on). Maximum operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wiring resistance: 1,500 ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. FDM-1 Automatic Addressing -The FDM-1 auto- matically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1 is set to address "56", then it will automatically assign itself to ad- dresses "56" and "57°. NOTE: "ones"addresses on the FDM-1 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first ad- dress, and terminals 8 and 9 use the second address. INSTALLATION FMM-1, FDM-1, and FZM-1 modules mount directly to a stan- dard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are pro- vided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. PRODUCT LINE INFORMATION FMM-1 Monitor module. FMM-101 Monitor module, miniature. FZM-1 Monitor module, two-wire detectors FDM-1 Monitor module, dual, two independent Class B circuits. SMB500 Optional surface-mount backbox. ARCHITECTS'/ENGINEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are avail- able from NOTIFIER. DN-6720 • 08/23/04 - Page 3 of 6 WIRING DIAGRAMS The following wiring diagrams are included: FDM-1, typical dual two-wire Style B initiating device circuit configuration. S FMM-101, typical two-wire Style B initiating device circuit configuration. FMM-1, typical two-wire initiating circuit configuration, NFPA Style B. FMM.1, typical four-wire fault-tolerant initiating circuit configuration, NFPA Style ft FMM-1, typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). FZM-1, interface two-wire conventional detectors, NFPA Style B. FZM-1, interface two-wire conventional detectors, NFPA Style D. FIRMA, relay control module used to disconnect a power supply. Fig. I FDM-1: Typical dual two-wire Style B initiating device circuit configuration. Two Initiating Device Circuits lqqppl (L&H) TO Next - each power-limited to Device (+) 230 pA max. @ 12 VOC max. MONITOR 47K EOL MODULE Resistor L7L 'D TENS 2 Fi Lj 5 4-o!ADL_ -) FROM Panel o.- Previous - Device Communication Line 32 VDC maximum Twisted-pair is recommended. All wiring shown is supervised and power limited. Connect modules to listec compatib1 NOTIFIER control panes only. ANY NUMBER of UL Listed contact closure devices may be used. 6822wM.w DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circLit. Install contact closure devices per manufacturer's installation instructions. '(- Ii TO NEXT ] DEVICE BLACKI 14 RED (-) (+) FMM-1 01 6789 6789 4(\'\1 4' 3I/t ,,F\\)))12 213 10 15 2 r ' 10 - VIOLET IYELLOW (+) (—) UL LISTED Compatible Control Panel 47KE0L INCLUDED Fig. 2 FMM-101: Typical two-wire Style B initiating device circuit configuration. 6720w1r1wn,f Page 4 of 6 - DN-6720 • 08/23/04 Connect modules to listed compatible NOTIFIER control panels only. All wiring shown is supervised and power limited. Install contact closure devices per manufacturers' installation instructions. Any number of UL-listed contact closure devices may be used. DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. V Fig. 3 FMM-1: Typical two-wire initiating device circuit configuration, NFPA Style B. TO Next iiDcxx Device MONITOR dL2E 0 or -jEJ IL .8 1 TENS 7 2P b '4, 3 . El 5 4 — Communication Loss ONES ADDRESS (optional connection for panels 0 which support this feature) 00 FUTURE FEATURE 6720wir2.wn,f Initiating Device Circuit (IDC) NFPA Style B, power limited: 230 pA max. @ 12 VDC max. 47K EOL Resistor ELR-47K -.) FROM Panel or Previous —1 Device Communication Line 32 VDC maximum. Twisted-pair is recommended. V Fig. 4 FMM-1: Typical four-wire fault-tolerant initiating circuit configuration, NFPA Style D. EOL Resistor is internal at terminals 8 & 9 FROM Panel or Previous Device tion Line mum. 5 d. anels e) V Fig. 5 FMM-1: Typical two-wire initiating circuit configuration for security systems (with alarm versus short capability). TO Next - Device MONITOR MODULE .JJ8 ) i TENS .-) 4 FROM Panel or Previous —4 Device J+) Communication Line 32 VDC maximum. Twisted-pair is recommended. 11L6 3IL1I . I[Ls 411I '- Communication Loss ONES AoDtfl (optional connection for panels çS 0 I which support this feature) 0 FUTURE FEATURE 6720wir4.wmf LJ Initiating Device Circuit (IDC) NFPA Style B, power limited: 230 pA max. @ 12 VDC max. 14K Series Resistor 47K EOL Resistor ELR-47K DN-6720• 08/23/04 - Page 5 of 6 Connect modules to listed compatible control panels only. WIRING Terminal wiring must be power limited. I 1.!1J DO NOT MIX fire alarm initiating, supervisory, or security devices on the same circuit. '' \ DO NOT LOOP wire under terminals. Break wire run to provide supervision of connections. THIS PAGE: Detectors must be UL listed compatible with module. Install detectors per manufacturers' installation instructions. Power to the interface module must be externally switched to reset the detectors. An FRM-1 relay control module can be used to switch power from a standard power supply; see Fig. 7 below. V Fig. 6 FZM-1: Interface two-wire conventional detectors, NFPA Style B. TO Next () Device INTERFACE MODULE .Eli 90O[i1 .,Ei.8 rn 3.9K EOL L 7 TENS 2 Resistor 4 6 3 i (included) L 5 NES 4 E... A2143-1 0 LOOP ADDRESS r FROM Panel or Previous Device cation Line ximum. r is ed. Listed Battery Backup 4 switched DC 4 power supply. A- Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. V Fig. 7 FZM-1: Interface two-wire conventional detectors, NFPA Style D. TO Next Device INTERFACE MODULE FROM Panel GxcX(j. or Previous Device Communication Line 32 VDC maximum. Twisted-pair is recommended. (-) Listed Battery Backup (+) switched DC power supply. Optional Branch Circuit TO Next Interface Module Module supervises supply voltage and detector loop. 3.9K EOL Resistor (included) required at terminals 8 & 9 A2143-10 -HflEfl7TENS 2 01 6 (. 3 LI5 ' 4 LOOP ONES ADDRESS L.J 6720w116.wmt V Fig. 8 FRM-1: Relay control module used to disconnect a power supply. c( FROM Panel or Previous Device Communication Line 32 VDC maximum. - Twisted-pair is recommended. TO Next Device DC POWER SUPPLY (+) Listed for Fire (—) Protection with Battery Backup Page 6 of 6 - DN-6720 • 08/23104 +) RELAY CONTROL MODULE 0 E19-1 O F8- 1 i7HF 2H. 01 6 3E LOOP ADDRESS 6720wir7.wmt CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:202 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models FMM-1, FMM-101, FZM-1, FSM-101, FDM1* monitor modules and Models FCM- 1, FRM-1 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. *Rev. 05-02-01 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . <. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 17, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager K-100 (Q NOTIFIEW A Subsidiary of Pittway Corporation MR Series Control Relays Section: Miscellaneous December 17, 1996 GENERAL The Air Products & Controls MR Series Multivoltage Con- trol Relays offer SPDT or DPDT 10 amp contacts which may be operated by one of four input control voltages. A single relay may be energized from a voltage source of 24 VDC, 24 VAC, 115 VAC, or 230 VAC by wiring to appropri- ate input terminals. Each relay contains a red light emitting diode (LED) which indicates the relay coil is energized. Relays may be "snapped apart" from a standard 4 module assembly and used independently. These devices are ideal for applications where local con- tacts are required for system status, remote contacts for control of electrical loads and general purpose switch- ing. They are suitable for use with HVAC, Temperature Control, Fire Alarm, Security, Energy Management, and Lighting Control Systems. The Air Products & Controls MR-199 Heavy Duty Power Relays are designed for control applications where 30 amp DPDT contacts are required. The 24 VDC coils are mounted in a rugged steel enclosure. MR SERIES FEATURES (Excluding MR- 199 Series) Each relay position may be energized from one of four input control voltages. Each relay position contains a red LED which illumi- nates when the coil is energized. This provides a time saving convenience when checking an installed sys- tem, no metering is required. Single, dual, or triple relay modules may be "snapped apart" from a standard 4 position master. SPDT or DPDT relays available. Available in dust-proof metal (with gray plastic cover on MR-101/C and MR-201/C) enclosures with LED view- ing port. Track mounting hardware to facilitate installation in stan- dard cabinets. UL recognized relays rated at 10,000,000 mechanical operations. MEA II 73-92-E S3403 (models with metal enclosure only) . S The MR-1011C _w• ••1t • •X2i '• L&i California: State 'Fire Marshal 7300-1004:101 The MR-1041C This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications lSO9001 00==1 ___________ or. anticipate all requirements. All specifications are subject to change without notice. Engineering and Manufacturing For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484.7118 Quality System Certified to N OTI Fl ER 12 Clintonville Road, Northford, Connecticut 06472 1 International Standard ISO-9001 Made in the U.S.A. DN-3477 - Pagel of 2 PRODUCT SPECIFICATIONS FOR MULTIVOLTAGE CONTROL RELAYS Power requirements: MR-I01 Position is rated at 0.015 amps (15 milliamps) @24VAC, 24 VDC, 115 VAC, 230 VAC. MR-201 Position is rated at 0.035 amps (35 milliamps) @24VAC, 24 VDC, 115 VAC, 230 VAC. Relays: MR-101 is UL recognized SPDT. MR-201is UL recognized DPDT. Enclosure: 18 gauge CRS, plated with 1/2" conduit knock- outs (top & bottom). The MR-1011C and MR-2011C in- clude a metal backbox with durable plastic cover. Contact Rating: 10.0 A @ 115 VAC. Ambient temperature: -50°C to +85°C. Dimensions: MR-1011r and MR-201/T are 3.0" (82 mm) H x 2.125" (54 mm) W x 1.5" (38.1 mm) D. MR-1041T and MR-204/Tare 3.0" (82 mm) H x 8.5" (215 mm) W x 1.5" (38.1 mm) D. MR-1011C and MR-2011C are 6.125" (130.2 mm) H x 3.25" (82 mm) W x 2.5" (63.5 mm) D. MR-1041C and MR-2041C are 6.125" (130.2 mm) H x 9.5" (241.3 mm) W x 2.5" (63.5 mm) D. PRODUCT SPECIFICATIONS FOR HEAVY DUTY POWER RELAYS Contact arrangement: DPDT standard. Contact rating: 30 Amps @ 300 VAC, 2 HP motor load. Coil power: MR-1 99X-13 is rated at 24 VDC @ 85 mA. Temperature range: -30°C to +50°C. Dimensions: MR-199X-13 is 3.13" (794 mm) H x 2.5" (63.5 mm) W x 2.31" (58.7 mm) D. MR-199X-131C is 5.31" (134.9 mm) H x 3.38" (85.9 mm) W x 3.13" (96.8 mm)D. PRODUCT LINE INFORMATION Model Description MR-1 01/T Single SPDT Relay with LED & Track Mount-. ing Hardware. MR-101/C . Single SPDT Relay With LED mounted in metal enclosure with plastic cover. MR-1 04/T 4-Position SPDT Relay with LED & Track Mounting Hardware. MR-1 04/C 4-Position SPDT Relay with LED mounted in metal enclosure. MR-201/T Single DPDT Relay with LED & Track Mounting Hardware. MR-2011C Single DPDT Relay with LED mounted in metal enclosure with plastic cover. MR-2041T 4-Position DPDT Relay with LED & Track Mounted Hardware. MR-204/C 4-Position DPDT Relay with LED mounted in metal enclosure. MR-199X-13 DPDT, 24 VDC, heavy-duty relay only MR-1 99X-I 3/C DPDT, 24 VDC, heavy-duty relay mounted in enclosure. MR SERIES RELAYS MODEL NUMBER - COIL VOLTAGE CONTACTS MOUNTING 24 VDC 24 VAC 115 VAC 230 VAC SPDT (iOA) DPDT (IOA) DPDT (30A) Track Spacer Enclosure MR-101/'r X X .X X I X MR-101/C X X X X I X MR-1041T X X X X 4 X MR-104/C X X X X. 4 X MR-201/T X X X X 1 X MR-201/C X X X X 1 - MR-2041T X X X X 4 X X MR-204/C X X X X 4 X MR-199X-13 X I X MR-199X-13/C X1.1 X Page 2 of 2 - DN-3477 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:106 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Air Products & Controls Inc., 1749 East Highwood, Pontiac, Ml 48340 Contact: *Richard Steele (248) 332-3900 *FA)( (248) 332-8807 DESIGN: Models MR-201/T, MR-204/T, MR-101/T, MR-104/T, MR-201/XT and MR-204/XT relay modules. These units are relay modules which provide single-pole, double throw contacts. Models MR-101/T, MR-201/T and MR-201/XT provide one set while Models MR-104/T, MR-204/T and MR-204/XT provide four sets of contacts. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 VAC, 18-35VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. *Rev. 05-28-2004 b.'. O This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager March 30, 2004 DN-5566 J-122 0 NOTIFIER® GENERAL Wheelock's patented 2-wire AS Series Audible Strobe Applicances; and AH Series Audible Devices offer more features with low current draw. Strobe options forwall mount models include 1 575cd or Wheelock's patented MCW multi-candela wall strobes with field selectrable candela settings of 15/30/75/110cd. Ceiling mount models incorporate Wheelock's patented MCC multi- candela ceiling strobe with field selectrable intensities of 15/30/75/ 95cd. Theaudible provides a selectable choice of eithera continous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or with a power supply with the Wheelock sync protocol, synchronization of the continous horn tone provides the temporal (code 3)tone (mandated by N FPA 72) simultaneously for all audible appliances. This ensurses a distrinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distrinctive. At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this puls the ability to silence the audible is achieved by using only2 wire. FEATURES ADNNFPNUFC/ANSI Compliant AS Series Audible Strobe Devices are available in wall and ceiling-mount models: Wall mountmodels offered are availablewith Field Selectrable Candela Settings of 15/30/75/110cd or 1575cd (single candela model) Ceiling mount models offered are available with field selectrable candela settings of 15/30/75/95cd Selectable Continous Horn or Temporal (Code 3) 3 Selectrable dBA settings (99, 95 abd 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash persecond overthe regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage Range" using filtered DC or unfiltered FWR input voltage Synchronize with Wheelock SM, DSM or power supply with built-in Wheelock sync protocol Fast installation with IN/0UT screw terminals using #12 and #18 AWG wires Wheelock AS Series Audible Strobe Devices and AH Series Audible Devices Section: Audio/Visual Devices CS 356 LISTED APPROVED ! California E 5946 State Fire / Marshal lvi E1 7125-0785:131 151-92-E AS Audible Strobe AH Audible GENERAL NOTES Strobes are designed to flash at 1 flash per second minimum overthe Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of 1 to 2 flashes per second and ADA Guildelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. AS Series Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0°C to 49'C) and maximum humidity of 93% (± 2%) AH-24 Series horns are listed under UL Standard 464 foraudible signal appliances (indoor use only). AH-24WP Series audible appliances are listed under UL Stan- dard 464 for indoor/outdoor use with a temperature range of - 31°F to 150°F (-35° Cto66° C) and maximum humidity of 95%. "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior this change, UL used the terminology "Listed Voltage Range". NOTIFIER® is a Honeywell company. This document is not intended to be used for installation purposes. We try to keep our IS09001 product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203)484-7118 INCINEERIN&MANUFACTURING NOTI F I E Rt 12 Clintonville Road, Northford, Connecticut 06472 QUALITY SYSTEMS /JWARNING!Y PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING, OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS, AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. ORDERING INFORMATION MODEL STROBE CANDELA NOW SYNC SYNC W/SM, DSM VDC WALL! CEILING MOUNT MOUNTING OPTIONS* AGCY APPROVALS - UL - MEA - CSFM - FM - BFP AS-24MCW-FR 15/30/75/110 X X 24 WALL A,B,DE,FG,H,J,N,O,R,X X X X X X AS-24MCW-FW 15/30/75/110 X X 24 WALL A,B,DE,F,G,H,J,N,O,R,X X X X X X AS-241575W-FR 15(75onAxis) X X 24 WALL A,BD,E,FG,H,J,N,O,R,X X X X X AS-121575W-FR 15(75onAxis) X X 12 WALL A,B,D,E,F,G,H,J,N,O,RX XI I X X X AS-24MCC-RN 15/30/75/95 X X 24 CEILING A,B,DE,F,G,H,J,NO,RX )( X X * * ASWP-2475W-FR 75 @ -31°F X I X 24 WALL I X X X X X AH-24-R - X X 24 WALL/CEILING A,BD,E,F,G,H,J,N,O,RX X X X X X AH-12-R - X X 12 WALL/CEILING A,B,D,E,F,G,H,J,N,O,RX X X X X X AH-24WP-R - X X 24 WALL/CEILING K X X X X X AH-12-WP-R - X X 12 WALL/CEILING K Fx F X X X X *Referto data sheet DN611 1 for Mounting Options NOTE: Due to continous development of our products, specifications and offerings are subject to change without notice in accordance with Notifier's standard terms and conditions b TABLE 1: RATINGS PER UL 1971 REGULATED INPUT STROBE MODEL VOLTAGE VOLTAGE CANDELA VDC RANGE (cd) VDC/FWR AS-24MCW 24 16.0-33.0 15/30/75/110 AS-241575W - 24 16.0-33.0 15 (750n axis) AS-121575W 12 8.0-17.5 15 (75 on axis) AS-24MCC 24 16.0-33.0 15/30/75/95 ASWP-247N 24 16.0-33.0 75 @ -31°F TABLE 2: DBA RATINGS FOR 12 VDC& 24 VDC SERIES AS/AH 12 & 24 VDC AUDIBLE DESCRIPTION VOLUME REVERBERANT DBA PERUL 464@IOFr. ANECHOIC DBA @IOFr. Continuous Horn High 91 99 Medium 88 95 Low 83 90 Code 3 Horn High 87 99 Medium 84 95 Low 79 90 NOTES: SM Sync Module is rated for 3.0 amperes @ 24 VDC. DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). SYNC MODELS/POWER SUPPLY INPUT AVERAGE MODEL VOLTAGE MEAN MOUNTING NUMBER (VDC) CURRENT OPTIONS 24 VDC SM-12/24-R 24 .028 W DSM-12/24-R 24 .035 W WIRING DIAGRAMS AS device non-synchronized. "' From PRECEDING DEVICE DEVICE orFACP or SIGNAL Page 2 of 4 - DN-5566 03/30/04 AS devices synchronized with SM Module single Class "B" (Style Y) circuit WITH audible silence feature. FACP SM -Q + STROBE STROBE NAG CIRCUIT STROBE EOLR - --0 SA OUT AUDIBLE NAC CIRCUIT AUDIBLE * & EOLR EOLRVALIJE DETERMINED BY FACP - AUDIBLE 1 NAG CIRCUIT(S) WIRING DIAGRAMS AS and AU devices synchronized with DSM Module dual Class "A" (Style Z) circuit with NO audible silence feature. DSM V & SYNC - - FACP] ff- & + IN 1 AS MINUS 1 + AUDIBLE AUDIBLE NAC CIRCUIT OUT AUDIBLE +IN2 AS AS AH AUDIBLE NAC OUT 2 CIRCUIT RETURN NOTES: AS/AH must be set on continuous horn tone, and connected to the SM or DSM Sync Module, to achieve synchronized temporal (Code 3) tone. AS and AH devices synchronized with multiple DSM Modules. INTERCONNECTING WIRING SHOWN. MAXIMUM OF TWENTY (20) DSM MODULES. AUDIBLE NAC DSM #1 plCCUlTv S-[AftAH STROBE A SYNC+ CIRCUIT rH SYNC -NAC ] AUDIBLE NAC CIRCUIT Y STROBE A SYNC+ NAC CIRCUIT -& SYNC- AUDIBLE DSM #3 -- NAC - riprt IT - T-TAS rAS - AH STROBE A L_J ® SYNC + N C AC L® SYNC - IRCUIT V TABLE3: AVAGEIMOi'IP AUDIBLE WLLw\lrALoBLESTReEraS RINXNrSTR38EMJCES 24VtCMJCS A1324 AS-241575W PS-24vON AS-24tvCAH PS-24M AS-24MXH 1375cd 13cd 30cd 75cd 113cd 135cd 135cd 15d 30cd 75cdj 95cd 115cd 177cd 13 dc 0.035 0.0130 0.099 0.135 0.213 0.303 0.355 0.480 0.135 0.145 0.238 0.330 0.355 0.480 (99)dBA 24 dc 0.050 0.0137 0.093 0.114 0.157 0.137 0.250 0.320 0.970 0.120 0.139 0.213 0.250 0.320 33vdc 0.069 0.005 0.098 0.138 0.138 0.136 0.213 0.250 0.131 0.113 0.146 0.177 0.213 0.250 15dc 0.020 0.114 0.078 0.113 0.203 0.282 0.340 0.465 0.084 0.26 0.222 0.309 0.340 0.465 IVEDW (95)dBA 24 dc 0.026 0.085 0.065 0.088 0.133 0.179 0.230 0.305 0.069 0.094 0.145 0.135 0.230 0.305 33dc 0.035 0.075 0.065 0.078 0.206 0.134 0.130 0.230 0.068 0.083 0.114 0.145 0.130 0.230 13dc 0.014 0.138 0.070 0.111 0.201 0.279 0.335 0.460 0.076 0.21 0.220 0.306 0.335 0.460 LON (99)dBA 24vdc 0.014 0.075 0.052 0.077 0.126 0.139 0.220 0.295 0.056 0.084 0.138 0.135 0.220 0.295 33dc 0.021 0.060 0.046 0.063 0.094 0.21 0.170 0.215 0.049 0.068 0.132 0.132 0.170 0.213 wu.. maw W4LL WALL AIDBLE AUDIBLE AUDIBLE AUDIBLE maw 2VDMXS STROBE ALCLE 2VtCMXaS AULE ________ S11t8E STROBE AH.2 1 AS. 21575W AH.2 S-121575 AH.2 AS-21375W 8dc 0.093 0.320 8dc 0.037 0.275 8c 0.030 0.265 MEDILIM LOIV(90) 12dc 0.138 0.260 dBA dBA 2dc 0.049 0.135 2dc 0.035 0.175 17.5 'dc 0.28 0.220 17.5 'dc 0.069 0.130 V.5 'dc 0.042 0.133 *Average RSM Current is per UL average method and Average Mean Current is per UL average mean method. AH and AS-12 models use average mean current. For rated in Rush and Peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS (FWR), see installation instructions. (Vl0(04 - D,n ,,f 4 CONTACT WHEELOCK FOR "INSTALLATION INSTRUCTIONS" (Wheelock #P83509 [AS], #P83641 "__"a' [AH-WP], and #P83519 [AH]) AND "GENERAL INFORMATION" SHEET (Wheelock #P82380) ON THESE PRODUCTS. THESE MATERIALS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS, THESE MATERIALS CONTAIN IMPORTANT INFORMATION THATSHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REQUIRED BY ALL DEVICES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES. FUSE RATINGS ON NAC CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL DEVICES ON THOSE CIRCUITS. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. VOLTAGE APPLIED: THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED INPUT VOLTAGE RANGE. INSTALLATION OF 100/110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. Note: USE AS/AN ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE AS SERIES ON CODED OR INTERRUPTED NAC CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF, AS THE STROBE MAY NOT FLASH. CONDUCTOR SPECIFICATIONS: CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURYOR DEATH TO YOU AND/OR OTHERS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained, and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state, and federal codes, regulations, and laws. Specification, application, installation, operation, maintenance, and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal, and other applicable building and fire standards, guidelines, regulations, laws, and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). ARCHITECTS' & ENGINEERS' SPECIFICATIONS The notification appliances shall be Wheelock's patented AS Series Audible Strobe and AH Series Audible Horn devices, and when synchronization is required, companion SM and DSM Sync Modules, or approved equivalents. AS Series devices and SM and DSM Sync Modules shall be listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired for Indoor Fire Protection Service). AH Series Audible Horn shall be listed under Standard 464 (Fire Protective Signaling). AS, AH, SM, and DSM devices shall be certified to meet FCC Part 15, Class B. The devices shall be designed for two-wire operation and shall provide either a continuous or temporal (Code 3) tone when constant voltage from a Notification Appliance Circuit (NACs) of the Fire Alarm Control Panel (FACP) is applied; or synchronized temporal (Code 3) horn and synchronized strobe when used in conjunction with the SM or DSM Sync Modules. The AS Series shall be designed so that the audible signal may be silenced while maintaining strobe activation (when used with the SM or DSM Sync Modules). The SM and DSM Sync Modules shall incorporate two inputs from Notification Appliance Circuits (NACs) for power connection from the Fire Alarm Control Panel (FACP): one for the strobe circuit (NAC), and one for the audible circuit (NAC). A single two-wire output shall control both the audible and visual appliances. Upon activation of the audible silence function of the FACP, the audible signal shall be silenced while maintaining strobe activation. Sound output at 10 feet (3.048 m) shall be field-selectable for 90, 95, or 99 dBA anechoic for both continuous or temporal (Code 3) tone. The AS Series shall provide listed strobe intensities of 15, 15/75, 30, 75, and 110 candela for wall-mount and/or 75 or 100 candela for ceiling-mount applications; with a flash rate of one flash per second minimum across the listed voltage range. The strobe shall incorporate a Xenon® flashtube enclosed in a rugged LEXAN® lens. The maximum allowable current at 24 VDC shall be 87 mA @ 15 cd, 102 mA @ 15/75 cd, 120 mA @ 30 cd, 177 mA @ 75 cd, and 202 mA @ 110 cd. All devices shall incorporate a reduced inrush circuit design. The strobe shall have a horizontal plane. The Sync Module shall be designed and available in two versions: the SM-12/24, for control of a single Class "B" NAC circuit; and a dual-output version, the DSM-12124, for control of either a single Class "A" or two Class "B" NAC circuits. The DSM dual-circuit version shall provide the additional capability of "daisy-chaining" i.e., the ability to interconnect multiple DSM's for synchronous horn and strobe operation on multiple NAC circuits. DSM-1 2/24 interconnection capability shall be for a maximum of 20 modules (40 Class "B" NAC circuits or 20 Class "A" NAC circuits). Rated average current requirement for the SM-12/24 shall be 0.014 amperes @ 12 VDC and 0.025 amperes @24 VDC; the DSM-12/24 shall be 0.020 amperes @ 12 VDC and 0.038 amperes @24 VDC. The SM Sync Module shall be capable of handling a three-ampere load at 12 or 24 VDC. The DSM Sync Modules shall be capable of handling a load of three amperes per circuit in the Class "B" mode, and three amperes per module in the Class "A" mode at 12 or 24 VDC. SM or DSM Sync Modules and AS Audible Strobes shall be designed as a system for continuous activation of the strobes should the Sync Module contacts fail in the passive state (i.e., contacts remain closed). In this default mode, the strobes shall revert to a non- synchronized default flash rate. AS/AH Series devices shall be designed for operation at 12 or 24 VDC, over their respective listed voltage ranges of 10.5 to 15.6 VDC; and 20.0 to 31.0 VDC. The units shall be designed for operation on filtered DC, or unfiltered VRMS. Rated average current for AS Series devices shall depend upon voltage and strobe intensity; current shall be as low as 0.058 amperes for 24 VDC versions and 0.145 amperes for 12 VDC versions. Rated average current for AH Series devices (volume set at high-dB output) shall be 0.041 amperes for 24 VDC versions and 0.113 amperes for 12 VDC versions. All versions shall be polarized for DC supervision and shall incorporate screw terminals for in/out field wiring of size #18 AWG (0.75 mm2) to #12 AWG (3.25 mm2). AS/AH shall incorporate a patented Universal Mounting Plate which shall allow mounting to single-gang, double-gang, 4(10.16 cm) square, 100 mm European backboxes or Wheelock's SHBB surface backbox. No additional trim plate shall be required for flush mounting. Dimensions for AS/AK appliances shall be 4.625" (11.7475 cm) square by 1.5" (3.81 cm) deep. Page 4 of 4 - DN-5566 . 03/30/04 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-I2WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP*2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed• by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, llocd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. *Corrected 08-20-04 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AI-I-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Corrected 08-20-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: AUGUST 20, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager