HomeMy WebLinkAbout5620 PASEO DEL NORTE; 127C; FPC2019-0115; PermitPERMIT REPORT
((7city of
Carlsbad
CARLSBAD, CA 92008-4466
Work Class: Fire Sprinklers
Track #:
Lot #:
Project #:
Plan #:
Construction Type:
Orig. Plan Check#:
Plan Check#:
Permit No: FPC2019-0115
Status: Closed - Finaled
Applied: 05/21/2019
Issued: 05/29/2019
Finaled Close Out: 09/26/2019
Inspector:
Final Inspection:
Print Date: 01/05/2021
Job Address: 5620 PASEO DEL NORTE, # 127C,
Permit Type: FIRE-Construction Commercial
Parcel #: 2110222202
Valuation: $47,626.24
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Project Title:
Description: JERSEY MIKES SUBS- SPRINKLER TI (27 HEADS)
Applicant: FPContractor:
JOHNSON CONTROL FIRE PROTECTION JOHNSON CONTROLS FIRE PROTECTION LP
MARCUS ENGLISH P0 BOX 3042
3568 RUFFIN RD BOCA RATON, FL 33431-0942
SAN DIEGO, CA 92123-2597 (561) 341-7780 -
(858) 633-9125
FEE AMOUNT
FIRE NFPA 13 or 13R System 7 - 100 heads $553.00
Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 760-602-8561 f I www.carlsbadca.gov
FPC20I9-01 15
5620 PASEO DEL NORTE #127C
JERSEY MIKES SUBS- SPRINKLER TI (27 HEADS)
2110222202
5/21/2019
Series RFII - 56 K-factor FPC20I9-01 15
"Royal Flush II" Concealed rm im,nir
Quick & Standard Response, Standard Coverage
General
Description
The TYCO Series RFII 5.6 K-factor,
"Royal Flush II" Concealed Pendent
Sprinklers Quick Response (3-mm
bulb) and Standard Response (5-mm
bulb), are decorative sprinklers fea-
turing a flat cover plate designed to
conceal the sprinkler. These sprinklers
are optimal for architecturally sensi-
tive areas such as hotel lobbies, office
buildings, churches, and restaurants.
Each sprinkler includes a Cover Plate!
Retainer Assembly and a Sprinkler!
Support Cup Assembly. The separa-
ble, two-piece assembly design pro-
vides the following benefits:
Allows installation of the sprinklers
and pressure testing of the fire pro-
tection system prior to installation of
a suspended ceiling or application of
the finish coating to a fixed ceiling.
Permits the removal of suspended
ceiling panels for access to building
service equipment without having
to first shut down the fire protection
system and remove sprinklers.
Provides for 1/2 in. (12,7 mm) of ver-
tical adjustment to allow a measure
of flexibility in determining the length
of fixed piping to cut for the sprinkler
drops.
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 4
The Series RFII Sprinklers are shipped
with a Disposable Protective Cap. The
Protective Cap is temporarily removed
during installation and replaced to help
protect the sprinkler during ceiling
installation or finish. The tip of the Pro-
tective Cap can be used to mark the
center of the ceiling hole into plaster
board or ceiling tiles by gently pushing
the ceiling product against the Pro-
tective Cap. When ceiling installa-
tion is complete, the Protective Cap is
removed and the Cover Plate/Retainer
Assembly is installed.
As an option, the Series RFII Standard
Response (5-mm bulb) "Royal Flush II"
Concealed Pendent Sprinklers can be
fitted with a silicone Air and Dust Seal.
(Refer to Figure 5.) The Air and Dust
Seal is intended for sensitive areas
where it is desirable to prevent air and
dust from the area above the ceiling to
pass through the cover plate.
EM
The Series RFll Concealed Pendent
Sprinklers described herein must be
installed and maintained in compliance
with this document and with the appli-
cable standards of the NATIONAL FIRE
PROTECTION ASSOCIATION (NFPA),
in addition to the standards of any
authorities having jurisdiction. Failure
to do so may impair the performance
of these devices.
The owner is responsible for maintain-
ing their fire protection system and
devices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted with
any questions.
Sprinkler
Identification
Number (SIN)
TY3531 - 3 mm bulb
1Y3551 - 5 mm bulb
SEPTEMBER 2018
Technical
Data
Sprinkler Approvals
Approvals apply only to the service
conditions indicated in the Design Criteria
section.
TY3531 (3 mm Bulb) is UL Listed, C-UL
Listed and NYC Approved (MEA 353-
01-E) as Quick Response.
1Y3531 (3 mm Bulb) is VdS Approved
(Certificate No. G4090007).
1Y3531 (3 mm Bulb) is FM and
LPCB Approved (Ref. No. 094a/10) as
Standard Response.
Note: FM and LPCB do not approve
concealed sprinklers for quick
response.
TY3551 (5 mm Bulb) is UL Listed, C-UL
Listed, FM Approved, LPCB Approved
(Ref. No. 094a/9), and NYC Approved
(MEA 353-01 -E) as Standard Response.
Approvals for Air and Dust Seal
UL and C-UL Listed for use with the RFII
Standard Response Concealed Sprinkler
(TY3551)
Maximum Working Pressure
Maximum 250 psi (17,3 bar) by UL,
C-UL, and NYC
Maximum 175 psi (12,1 bar) by FM, VdS,
and LPCB
Temperature Rating
155°F (68°C) Sprinkler with
139°F (59°C) Cover Plate
200°F (93°C) Sprinkler with
165°F (74°C) Cover Plate
TFPI8I
SPRINKLER/SUPPORT CUP
ASSEMBLY
THREAD INTO RETAINER
SUPPORT WITH THREAD
CUP UNTIL 0 0 '_- DIMPLES
MOUNTING
SURFACE IS U EJECTION
FLUSH WITH Ii SPRING CEILING H /
SOLDER ' -. COVER
TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY
FIGURE 1
MODEL RFII CONCEALED SPRINKLER
ASSEMBLY
TFPI8I
Page 2 of 4
Discharge Coefficient
K= 5.6 GPM/psi112 (80,6 LPM/bar112)
Adjustment
1/2 inch (12,7 mm)
Finishes
See the Ordering Procedure section.
Physical Characteristics
Frame ............................Bronze
Support Cup ...................Plated Steel
Guide Pins..................Stainless Steel
Deflector ..........................Bronze
Compression Screw ..................Brass
Bulb...............................Glass
Cap .....................Bronze or Copper
Sealing Assembly. . Beryllium Nickel w/TEFLON
Cover Plate .........................Brass
Retainer............................Brass
Ejection Spring ..............Stainless Steel
Design
Criteria
The TYCO Series RFII 5.6 K-factor,
"Royal Flush Il" Concealed Pendent
Sprinklers are intended for fire protec-
tion systems designed in accordance
with the standard installation rules
recognized by the applicable Listing
or Approval agency; for example, UL
Listing is based on NFPA 13 and VdS
Approval is based on the CEA 4001.
For more information on LPCB and VdS
Approvals, contact Johnson Controlss
at the following office:
Enschede, Netherlands
Telephone: 31-53-428-4444
Fax: 31-53-428-3377
The Series RFII Concealed Pendent
Sprinklers are only listed and approved
with the Series RFll Concealed Cover
Plates having a factory applied finish.
Do not use the Series RFII in applica-
tions where the air pressure above the
ceiling is greater than that below. Down
drafts through the Sprinkler/Support
Cup Assembly can delay sprinkler
operation in a fire situation.
Operation
When exposed to heat from a fire, the
Cover Plate, normally soldered to the
Retainer at three points, falls away to
expose the Sprinkler/Support Cup
Assembly.
The Deflector - supported by the
Guide Pins - then drops down to its
operational position.
The glass bulb contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, activating the sprinkler and
allowing water to flow.
1/2 NPT
FRAME
SUPPOR
CUP WITF
ROLL FOR'J
THREAD
GUIDE
PINS (2)
DEFLECTOR
Installation
The TYCO Series RFII 5.6 K-factor,
"Royal Flush II" Concealed Pendent
Sprinklers must be installed in accor-
dance with this section.
General Instructions
Do not install any bulb-type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 155°F (68°C) and 3/32
inch (2,4 mm) for the 200°F (93°C) tem-
perature ratings.
A leak-tight 1/2 inch NPT sprinkler
joint should be obtained by applying a
minimum to maximum torque of 7 to 14
ft.-lbs. (9,5 to 19,0 Nm). Higher levels
of torque can distort the sprinkler Inlet
with consequent leakage or impairment
of the sprinkler.
EALING
SEMBLY
CAP
BULB
PRESSION
)CREW
LECTOR
ROPPED
POSITION)
Do not attempt to compensate for
insufficient adjustment in the Sprinkler
by under- or over-tightening the Sprin-
kler/Support Cup Assembly. Re-adjust
the position of the sprinkler fitting to
suit.
Step 1. Install the sprinkler only in the
pendent position with the center-line
of the sprinkler perpendicular to the
mounting surface.
Step 2. Remove the Protective Cap.
Step 3. With pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step 4. Wrench-tighten the sprinkler
using only the RFII Sprinkler Wrench.
(Refer to Figure 3.) Apply the RFII
Sprinkler Wrench to the Sprinkler as
shown in Figure 3.
-\
I I I I V
MANUFACTURER DEFLECTOR COVER PLATE
PRESET GAP IN DROPPED RETAINER
3/32 (2,4 mm) POSITION ASSEMBLY
COVER PLATE
DIAMETER
DIMENSION A
3/16 to 11/16
(4,8 to 17,5 mm)
REFERENCE
COVER PLATE - PROFILE DEPTH
DIMENSION B
3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm)
3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm)
FIGURE 2
SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS
TFPI8I
Page 3 of 4
FACE OF
SPRINKLER
FITTING
SPRINKLER
SUPPORT CUP
ASSEMBLY
1/2 (12,7 mm)
THREADED
D ADJUSTMENT
FACE
OF CEILING,
RETAINING RING
MOUNTING
SURFACE
CLEARANCE HOLE
- DIAMETER
DIMENSION
Step 5. Replace the Protective Cap
by pushing it upwards until it bottoms
out against the Support Cup. (Refer
to Figure 4.) The Protective Cap helps
prevent damage to the Deflector and
Arms during ceiling installation and/or
finish. You can also use the Protective
Cap to locate the center of the clear-
ance hole by gently pushing the ceiling
material up against the center point of
the Protective Cap.
LI1IL
As long as the Protective Cap remains
in place, the system is considered "Out
of Service".
Step 6. After the ceiling has been
completed with the 2-1/2 in. (63,5 mm)
diameter clearance hole and in prep-
aration for installing the Cover Plate!
Retainer Assembly, remove and discard
the Protective Cap. Verify that the
Deflector moves up and down freely.
If the Sprinkler is damaged and the
Deflector does not move up and down
freely, replace the entire Sprinkler.
Do not attempt to modify or repair a
damaged sprinkler.
Step 7. When installing an Air and
Dust Seal, refer to Figure 5; otherwise,
proceed to Step 8. To attach the Air
and Dust Seal, verify the angle of the
outside edge of the seal is oriented
according to Figure 5. Start the edge of
the Retainer in the grooved slot of the
Air and Dust Seal and continue around
the retainer until the entire Air and Dust
Seal is engaged.
TFPISI
Page 4 of 4
Step 8. Screw on the Cover Plate!
Retainer Assembly until the Retainer
(shown in Figure 2) or the Air and Dust
Seal (shown in Figure 5) contacts the
ceiling. Do not continue to screw on the
Cover Plate/Retainer Assembly so that
it lifts a ceiling panel out of its normal
position. If you cannot engage the
Cover Plate/Retainer Assembly with
the Support Cup or you cannot engage
the Cover Plate/Retainer Assembly suf-
ficiently to contact the ceiling, you must
reposition the Sprinkler Fitting.
Care and
Maintenance
The TYCO Series RFII 5.6 K-factor,
"Royal Flush II" Concealed Pendent
Sprinklers must be maintained and
serviced in accordance with this
section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
that it controls, obtain permission to
shut down the affected fire protection
system from the proper authorities
and notify all personnel who may be
affected by this action.
Absence of the Cover Plate/Retainer
Assembly can delay sprinkler opera-
tion in a fire situation.
When properly installed, there is a
nominal 3/32 in. (2,4 mm) air gap
between the lip of the Cover Plate and
the ceiling, as shown in Figure 2.
This air gap is necessary for proper
operation of the sprinkler. If the ceiling
requires repainting after sprinkler
installation, ensure that the new paint
does not seal off any of the air gap.
Do not pull the Cover Plate relative to
the Enclosure. Separation may result.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers - before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must•
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb. (Ref. Installa-
tion Section.)
Exercise care to avoid damage to sprin-
klers before, during, and after instal-
lation. Replace sprinklers damaged
by dropping, striking, wrench twist-
ing, wrench slipping, or the like. Also,
replace any sprinkler that has a cracked
bulb or that has lost liquid from its bulb.
(Refer to the Installation section.)
If you must remove a sprinkler, do not
reinstall it or a replacement without
reinstalling the Cover Plate/Retainer
Assembly. If a Cover Plate/Retainer
Assembly becomes dislodged during
service, replace it immediately.
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the NATIONAL FIRE PROTECTION
ASSOCIATION, for example, NFPA 25,
in addition to the standards of any other
authorities having jurisdiction. Contact
the installing contractor or sprinkler
manufacturer regarding any questions.
Automatic sprinkler systems should be
inspected, tested, and maintained by a
qualified Inspection Service in accor-
dance with local requirements and/or
national code.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for
availability. When placing an order,
indicate the full product name.
Sprinkler/Support Cup Assembly
Specify: Series RFII (specify SIN),
K=5.6, "Royal Flush II" Pendent Sprin-
klers (specify) temperature rating, P/N*
(specify):
155°F (68°C 200°F (93°C
TY3531 51-792-1-155 51-792-1-200
TY3551 51-790-1-155 51-790-1-200
Use Suffix "I" for ISO 7-1 connection; for example,
51-792-1-155-I
Separately Ordered Cover Plate/
Retainer Assembly:
Specify: (temperature rating from
below) Series RFII Concealed Cover
Plate with (finish), P/N (specify).
139°F (59°C)(a) 165°F (74°C)(b)
Grey White
(RAL9002) .... 56-792-0-135 56-792-0-165
Brass..........56-792-1-135 56-792-1-165
Pure White (c)
(RAL9010) .... 56-792-3-135 56-792-3-165
Signal White
(RAL9003).... 56-792-4-135 56-792-4-165
Jet Black
(RAL9005).... 56-792-6-135 59-792-6-165
Brushed
Chrome........56-792-8-135 56-792-8-165
Chrome........56-792-9-135 56-792-9-165
Custom ........56-792-X-135 56-792-X-165
For use with 155°F (68°C) sprinklers.
For use with 200°F (93°C) sprinklers.
Eastern Hemisphere sales only.
Sprinkler Wrench
Specify: RFII Sprinkler Wrench,
P/N 56-000-1-075
Air and Dust Seal
Specify: Air and Dust Seal,
P/N 56-908-1-001
1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700
02018 Johnson Controls. All rights reserved. All specifications and other Information shown were current as of document revision dale and are subject to change without notice. Johnson /1
i)11 '
'
NATIONAL FIRE PROTECTION ASSOCIATION and NFPAa,o registered tradon,a,ke at National Fire PnvvAvn Association;
TEFLON Is registered trademark at DuPont Controls
Worldwide I t11,ca Contacts www.tyco-fire.com
Series TY-FRB, 56 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General
Description
The TYCO Series TY-FRB, 5.6 K-factor,
Upright (TY313) and Pendent (TY323)
Sprinklers described in this data sheet
are quick response, standard coverage,
decorative 3 mm glass bulb-type spray
sprinklers designed for use in light or
ordinary hazard, commercial occupan-
cies such as banks, hotels, and shop-
ping malls.
The recessed version of the Series
TY-FRB Pendent Sprinkler, where
applicable, is intended for use in areas
with a finished ceiling. This recessed
pendent sprinkler uses one of the
following:
A two-piece Style 15 Recessed
Escutcheon with recessed adjust-
ment up to 5/8 in. (15,9 mm) from
the flush pendent position.
A two-piece Style 20 Recessed
Escutcheon with recessed adjust-
ment up to 1/2 in. (12,7 mm) from
the flush pendent position.
The adjustment provided by the
Recessed Escutcheon reduces the
accuracy to which the fixed pipe drops
to the sprinklers must be cut.
Intermediate level versions of Series
TY-FRB Sprinklers are described in
Technical Data Sheet TFP357. Sprin-
kler guards and shields are described
in Technical Data Sheet TFP780.
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 4
NOTICE
The TYCO Series TY-FRB Sprinklers
described herein must be installed
and maintained in compliance with
this document, as well as with the
applicable standards of the National
Fire Protection Association, in addition
to the standards of any other authori-
ties having jurisdiction. Failure to do so
may impair the performance of these
devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identification
Number (SIN)
TY313.... Upright 5.61K, 1/2 in. NPT
TY323. . . .Pendent 5.61K, 1/2 in. NPT
Technical
Data
Approvals
Refer to Table A
Maximum Working Pressure
175 psi (12.1 bar)
250 psi (17.2 bar)*
The maximum working pressure of 250 psi (17.2 bar)
only applies to the listing by Underwriters Laborato-
ries, Inc. (UL).
Discharge Coefficient
K=5.6 GPM/p51½ (80,6 LPM/bar½)
Temperature Rating
Refer to Table A
Finishes
Sprinkler: Refer to Table B
Recessed Escutcheon: White Coated,
Black Coated, Chrome Plated, or Brass
Plated
Physical Characteristics
Frame ............................Bronze
Button ......................Brass/Copper
Sealing Assembly ... Stainless Steel w/TEFLON
Bulb...............................Glass
Compression Screw .................Bronze
Deflector ..........................Bronze
AUGUST 2018
Operation
The glass bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The TYCO Series TY-FRB, 5.6 K-factor,
Upright (TY313) and Pendent (TY323)
Sprinklers are intended for fire protec-
tion systems designed in accordance
with the standard installation rules
recognized by the applicable Listing or
Approval agency (such as, UL Listing
is based on the requirements of NFPA
13, and FM Approval is based on the
requirements of FM's Loss Prevention
Data Sheets). Only the Style 15 or Style
20 Recessed Escutcheon is to be used
for recessed pendent installations.
TFPI72
TFPI72
Page 2 of 4
Components:
1 - Frame
2 - Button
3 - Sealing
Assembly
* Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression
Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm)
6 - Deflector * DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN
STYLE 15 or 20
RECESSED
ESCUTCHEON
7/16' _______ I (111mm) _____
2'
(50,8 mm)
______
I NOMINAL
(34,9 mm)
FLATS
MAKE-IN _____
13 2"
(50,8 mm) WRENCH
1/2' NPT** DEFLECTOR* 2-7/8" (73,0 mm) DIA.
CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT
FIGURE 1
SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE
Installation
The TYCO Series TY-FRB, 5.6 K-factor,
Upright (TY313) and Pendent (1Y323)
Sprinklers must be installed in accor-
dance with this section.
General Instructions
Do not install any bulb-type sprin-
kler if the bulb is cracked or there is
a loss of liquid from the bulb. With the
sprinkler held horizontally, a small air
bubble should be present. The diam-
eter of the air bubble is approximately
1/16 in. (1,6 mm) for the 135°F(57°C)and
3/32 in. (2,4 mm) for the 286°F (141°C)
temperature ratings.
A leak-tight 1/2 in. NPT sprinkler joint
should be obtained by applying a
minimum to maximum torque of 7 to
14 lb-ft (9,5 to 19,0 N•m). Higher levels
of torque can distort the sprinkler Inlet
with consequent leakage or impairment
of the sprinkler.
Do not attempt to compensate for
insufficient adjustment in the Escutch-
eon Plate by under- or over-tightening
the sprinkler. Re-adjust the position of
the sprinkler fitting to suit.
Upright and Pendent Sprinklers
The Series TY-FRB Upright and
Pendent Sprinklers must be installed
in accordance with the following
instructions.
Step 1. Install Pendent sprinklers in the
pendent position. Install upright sprin-
klers in the upright position.
Step 2. With pipe-thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Figure 2). With ref-
erence to Figure 1, apply the W-Type 6
Sprinkler Wrench to the wrench flats.
Torque sprinklers 7 to 14 lb-ft (9,5 to
19,0 Nm).
Recessed Pendent Sprinklers
The Series TY-FRB Recessed Pendent
Sprinklers must be installed in accor-
dance with the following instructions.
Step A. After installing the Style 15
or Style 20 Mounting Plate over the
sprinkler threads, and with pipe-thread
sealant applied to the pipe threads,
hand-tighten the sprinkler into the
sprinkler fitting.
Step B. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Figure
3). With reference to Figure 1, apply the
W-Type 7 Recessed Sprinkler Wrench
to the sprinkler wrench flats. Torque
sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m).
Step C. After ceiling installation and
finishing, slide on the Style 15 or Style
20 Closure over the Series TY-FRB
Sprinkler and push the Closure over the
Mounting Plate until its flange comes in
contact with the ceiling.
/ WRENCH RECESS
/ (USE ONLY
FIGURE 2
W-TYPE 6
SPRINKLER WRENCH
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 3
W-TYPE 7 RECESSED
SPRINKLER WRENCH
TFPI72
- -- Page 3of4
Care and
Maintenance
The TYCO Series TY-FRB, 5.6 K-factor,
Upright (TY313) and Pendent (TY323)
Sprinklers must be maintained and ser-
viced in accordance with this section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
that it controls, obtain permission to
shut down the affected fire protection
systems from the proper authorities
and notify all personnel who may be
affected by this action.
Absence of the outer piece of an
escutcheon, which is used to cover
a clearance hole, can delay sprinkler
operation in a fire situation.
The owner must assure that the sprin-
klers are not used for hanging any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster; otherwise, non-
operation in the event of a fire or inad-
vertent operation may result.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb. (Ref. Installa-
tion Section.)
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the National Fire Protection Asso-
ciation (e.g., NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or product manufacturer
with any questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product name and Part Number
(P/N).
Sprinkler Assemblies with NPT
Thread Connections
Specify: Series TY-FRB Upright or
Pendent (specify) Sprinkler, SIN
(specify), K=5.6, Quick Response,
(specify) temperature rating, (specify)
finish, P/N (specify, refer to Table A).
Recessed Escutcheon
Specify: Style 15 Recessed Escutch-
eon with (specify*) finish, P/N (specify*)
Specify: Style 20 Recessed Escutch-
eon with (specify*) finish, P/N (specify*)
* Refer to Technical Data Sheet TFP770
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
2-7/8 DIA.
(73,0 mm)
2-1/4 DIA.
FACE OF (57,2 mm)
SPRINKLER
FITTING 5/8 (15,9 mm)
FLUSH
3/85/0
MOUNTING 1/8"
SURFACE (3,2 mm)
CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm)
1YFRB PLATE 3/4 (19,1 mm)
FIGURE 4
SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323)
WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15
RECESSED ESCUTCHEON
- 2-7/8 DIA.
(73,0 mm)
FACE OF
SPRINKLER - 2-1/4" DIA.
FITTING (57,2 mm)
5/16±1/4 1/2" (12,7 mm) (7,9±6,4 mm) FLUSH
_
$
MOUNTING
L(312 SURFACE
CLOSURE SERIES MOUNTING 1-3/8"(34,9mm)
TY-FRB PLATE 7/8" (22,2 mm)
FIGURE 5
SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323)
WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20
RECESSED ESCUTCHEON
TFPI72
Page 4 of 4
SPRINKLER FINISH (See Note 7)
K
FACTOR TYPE TEMPERATURE BULB LIQUID
COLOR
NATURAL
BRASS
I CHROME
PLATED 1 POLYESTERv
135-F (57-C) Orange
UPRIGHT
(TY313) 155°F (68°C) Red
175°F (79°C) Yellow and 1, 2, 3, 4, 5, 6
PENDENT
(TY323) 200°F (93°C) Green
286°F (141°C) Blue 5.6
1/2 in. NPT ________________
135°F (57°C) Orange
RECESSED
PENDENT
(TY323)
Figures 4a and 5b
1,2,3,4 155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
Notes:
Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the City of New York under MEA 354-01-E.
VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.)
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers.
Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.
Installed with Style 15 (1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable.
Installed with Style 20 (1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable.
C. Frame and Deflector only. Listings and approvals apply to color (Special Order).
TABLE A
LABORATORY LISTINGS AND APPROVALS FOR
5.6 K-FACTOR SPRINKLERS
P/Na 77—XXX—X—)OO(
CHROME PLATED
Notes:
a. Eastern Hemisphere sales only
TABLE B
SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS
PART NUMBER SELECTION
I SPRINKLER
FINISH
1 NATURAL BRASS
PURE WHITE (RAL9010)a
POLYESTER
SIGNAL WHITE (RAL9003)
-
POLYESTER
JET BLACK (RAL9005)
POLYESTER
TEMPERATURE
RATINGS
135 135-F (57-C)
155 1 155°F(68°C)
175 I 175°F (79°C)
200 I 200°F (93°C)
286 1 286°F(141°C)
SIN
370 I 5.6K UPRIGHT (1/2 in.NPT) I TY313
371 5.6K PENDENT (1/2 in.NPT) TY323
Notes:
a. Use suffix '1" for ISO 7-1 connection; for example,
77-370-4-175-I
1400 Pannbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 iil r
02018 Johnson Controls. All rights reserved. All specifications and ether Information shown were current as of document revision dote and are subjectte change without notice. Johnson '.',i Ø
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered twdnmo,l,n SI National Fire Protection Association;
TEFLON Is registered tradanrork at DuPed
0*
FLUSH INTERMEDIATE EXTENDED RECESSED PLAIN BARREL
Dry Type Standard Spray
Pendent, Intermediate Level Pendent
& Recessed Pendent
V3605 STANDARD RESPONSE
V3606 QUICK RESPONSE t
SLEEVE AND
SKIRT
COVERAGE:
The Model V36 Series Dry Type Pendent and Recessed Pendent Sprinklers have been redesigned
utilizing stainless steel internal components. The V36 Dry Sprinkler is used in special applications
such as freezing environments and conditions where sediment or foreign materials might accumulate
in ordinary drop nipples.
The Model V3606 and V3605 Intermediate Level Pendent sprinklers incorporate a water shield plate
to prevent water from higher level sprinklers from interfering with normal operation. These intermedi-
ate level sprinklers are designed for use in intermediate levels of rack storage or other open grate
storage arrangements, where they may be exposed to upper level or ceiling level sprinklers.
Available in either standard or quick response versions, the Model V36 Dry Type Pendent Sprinkler
utilizes a frangible glass bulb. At the bulb's rated temperature, the sprinkler opens releasing the bulb
seat assembly, causing the inner tube assembly to move, allowing the spring assembly to pivot along-
side the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector,
in an approved discharge pattern.
The heart of the Model V36 sprinkler's proven actuating assembly is a hermetically sealed frangible
glass bulb that contains a precisely measured amount of fluid. When heat is absorbed, the liquid
within the bulb expands increasing the internal pressure. At the prescribed temperature the internal
pressure within the bulb exceeds the strength of the glass causing the glass to shatter. This results in
water discharge which is distributed in an approved pattern.
For coverage area and sprinkler placement, refer to NFPA 13 standards.
JOB OWNER CONTRACTOR ENGINEER
System No. Submitted By Spec Sect Para___________
Location Date Approved
www.victaulic.com
vIcTAULIc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
REV ...H
JtauIicr
40.60.J
FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.60
V36, K56 C®
Pendent, Intermediate Level Pendent
LISTED
Dry Type Standard Spray
II & Recessed Pendent
V3605 STANDARD RESPONSE
V3606 QUICK RESPONSE
FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED
SKIRT
TECHNICAL SPECIFICATIONS:
Exaggerated for clarity
Models: V3606 and V3605
Style: Pendent, Recessed Pendent or
Intermediate Level Pendent
Nominal Orifice Size: 1h'/13 mm
Orifice Insert: Stainless steel per UNS S30300
K-Factor: 5.6 Imp./8.1 S.l.'
Nominal Thread Size: 1' NPT/33.7 mm
Max. Working Pressure: 175 psi/1200 kPa
Factory Hydrostatic Test:
100% @ 500 psi/3450 kPa
Mm. Operating Pressure: 7psi/48kPa
Temperature Rating: See chart on page 2
MATERIAL SPECIFICATIONS
Deflector: Brass per UNS 022000 or Stainless
Steel per UNS S30400
Bulb: Glass with glycerin solution.
Bulb Nominal Diameter:
Standard: 5.0 mm
Quick Response: 3.0 mm
Split Spacer: Stainless steel per UNS S30300
Load Screw: Brass per UNS 036000
Pip Cap: Stainless steel per UNS S30300
Spring Seal Assembly: Teflon* coated Beryllium
nickel alloy and stainless steel per UNS
S30300
Frame: Die cast brass
Outer Tube: Galvanized steel pipe
Inner Tube: Stainless steel per UNS S30400
Escutcheon/Plate: 1010 - 1018 mild steel and
stainless steel
Torsion Spring: SST Wire
ACCESSORIES
Installation Wrench: Model V36 Open End and
Recessed Wrenches fit all V36 Series frames.
Sprinkler Finishes:
Plain brass
Chrome plated
White painted t A
Flat black painted t A
Custom painted t A
Wax
Proprietary Nickel Teflon* Coated A
For cabinets and other accessories refer to
separate sheet.
A For K-Factor when pressure is measured in
Bar, multiply S.I. units by 10.0.
* Teflon is a registered trademark of Dupont Co.
t Not available on the Intermediate Level Style
Pendent.
A Models V3606/V3605 are UL Listed for cor-
rosion resistance in all configurations
NOTE: Weather resistant escutcheon available
upon request.
www.vlctaulic.com
VICTAULIC Is A REGISTERED TRADEMARK OF vrcTAuuC COMPANY. 02009 vICTAULIc COMPANY. ALL RIGHTS RESERVED.
40.60 .2
\4tauliIII
REVH
FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40.60
V36, K56 C®
LISTED
Dry Type Standard Spray
Pendent, Intermediate Level Pendent
& Recessed Pendent
7f 4
V3605 STANDARD RESPONSE
V3606 QUICK RESPONSE
FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED
SKIRT
APPROVALS/LISTINGS
l Listings and approval as of printing.
A For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.
*Listed for all hazards.
t Approved for V3605 and V3606 dry sprinklers up to 48 length.
RATINGS All glass bulbs are rated for temoeratures from -67°F/-55°C to those shown in table below.
Sprinkler Temperature Nominal
Classitication
Ordinary
Temperature
Temperature
Rating
135
57
- F/ C
Maximum Ambient
Temperature Allowed
EIS
38
Glass Bulb Color
Orange
Ordinary 155
68
100
38 -
Red
r
Intermediate i 200
93
150
65 CTi*Yi
Intermediate 286
141
225
107 Blue
www.victaulic.com
VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
REVH
\4taulic
40.60 .3
FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.60
V36, K56
Dry Type Standard Spray
Pendent, Intermediate Level Pendent
& Recessed Pendent
V3605 STANDARD RESPONSE
V3606 QUICK RESPONSE
ORDERING INFORMATION
I LISTED
ft Allft
FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED
SKIRT
Please specify the following when ordering:
Sprinkler Model Number
------------------------------------------
Style
Temperature Rating
K-Factor:
Thread Size
Quantity
Sprinkler Finish
Escutcheon Finish
Wrench Model Number
AVAILABLE WRENCHES Model V36 Open End and Recessed Wrenches fit all V36 Series frames.
fe00
www.victaulic.com
.,4tauiice
VICTAULIC IS REGISTERED TRADEMARK OF VlcTAUUc COMPANY. 2009 vIcTAULIC COMPANY. ALL RIGHTS RESERVED.
40.604 REV
FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS
V36, K56
Dry Type Standard Spray
Pendent, Intermediate Level Pendent
& Recessed Pendent
V3605 STANDARD RESPONSE
V3606 QUICK RESPONSE
tL
FLUSH
.1
SLEEVE AND PLAIN BARREL
SKIRT
FAI
LISTED
INTERMEDIATE EXTENDED RECESSED
WARNING WARNING
Always read and understand installation, care, and maintenance
instructions, supplied with each box of sprinklers, before proceeding
with installation of any sprinklers.
Always wear safety glasses and foot protection.
Depressurize and drain the piping system before attempting to
install, remove, or adjust any Victaulic piping products.
Installation rules, especially those governing obstruction, must be
strictly followed.
Painting, plating, or any re-coating of sprinklers (other than that sup-
plied by Victaulic) is not allowed.
O Failure to follow these instructions could result in serious personal
injury and/or property damage.
The owner is responsible for maintaining the fire protection system and
devices in proper operating condition. For minimum maintenance and
inspection requirements, refer to the current National Fire Protection
Association pamphlet that describes care and maintenance of sprinkler
systems. In addition, the authority having jurisdiction may have addi-
tional maintenance, testing, and inspection requirements that must be
Olt
followed.
If you need additional copies of this publication, or if you have any 610 questions about the safe installation of this product, contact Victaulic
World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031
USA, Telephone: 001-610-559-3300.
www.victaulic.com \JtauIac VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
REV.H 40.60_5
FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.60
V36, K5.6 JUSTED
Dry Type Standard Spray
Pendent, Intermediate Level Pendent
& Recessed Pendent
V3605 STANDARD RESPONSE
'13606 QUICK RESPONSE
FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED
SKIRT
DIMENSIONS NOTE: The "A" dimension of a dry sprinkler, which extends into a freezer from a wet piping system,
must take into account the wall or ceiling thickness of the freezer. See IMPORTANT INSTALLATION
INFORMATION later in this document.
Tee with same cutlet size
as sprinkler thread size.
See important Installation
- -
NPT
Information later in this
document
fl-------fl
,
-- ___________________
I
Tee with same cutlet size
as sprinkler thread size.
See 'Important Installatior
Information',later in this
document
1 NPT '
'A'
(Mm. 1W) 1½" Mm.Dia
in ceiling
(Mm
Two 1V)
n. Ho)ein
Hole
1IW Mm. Din.
Ceiling
r
3" Din
ece
Escutcheon
ia.
W Mm.
Flush --,
Sleeve and Skirt
Tee with tame outlet size Tee with same outlet size
as sprinkler thread size. as sprinkler thread size.
I I I See'lmpoo ant Installation See'lmportant Installation
Information",later in this )nformatiori later in this
document 1 document
PT
1"NPT
(Min.
(Mm. 1'/u')
V7TI T A. 1
3' Dia.—.
Intermediate Level Pendent Plain Barrel
11 Tee with same outlet size fl fl Tee with same outlet size
/ ' ' as sprinkler thread size. ' ,,, I as sprinkler thread size.
See'lmportant Installation Installation
_______________ InformationI later in ____________
Information, later in this
1" NPT this document 1' NPI document
'A' 1½"Min.Dia.
(Mm. t 'A') Hole in Ceiling
(Mm Collar
ie'°ttm
--
tHol
2" Mm Din.
3~' Mm. e in Ceiling
Two Piece 5" Max.
Escutcheon
Ceiling Cup Max.
Extended
________ Recessed
www.victaulic.com \,4'tauIiC' VICTAULIC Is A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
40.60 ,6 REV
FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS . 40.60
V369 K5.6 LISTED
Dry Type Standard Spray Mak Pendent, Intermediate Level Pendent
& Recessed Pendent A1111111111111111 11111111111111h
MM
V3605 STANDARD RESPONSE
V3606 QUICK RESPONSE
FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED
SKIRT
DISTRIBUTION PATTERNS MODELS V3606, V3605
PENDENT, RECESSED PENDENT & INTERMEDIATE LEVEL PENDENT
DISTRIBUTION PATTERNS - TRAJECTORY
8'
2.4 m
6'
1.8 m
4'
1.2 m
2'
0.6 m
0
2' 4' 6' 8' 10' 12' 14'
0.6 m 1.2 m 1.8 m 2.4 m 3.0 m 3.7 m 4.3 m
7ps1 —u.—. 15 psi 30ps1
48 kPa 103 kPa 207 kPa
NOTES:
1 Data shown is approximate and can vary due to differences in installation.
2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for
these specific Victaulic FireLock automatic sprinklers. They are provided as information for
guidance in avoiding obstructions to sprinklers and should not be used as minimum sprin-
kler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the
Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations
and area of coverage requirements. Failure to follow these guidelines could adversely affect the
performance of the sprinkler and will void all Listings, Approvals and Warranties.
3 All patterns are symmetrical to the centerline of the waterway.
www.victaulic.com \/(tauIic. vicTAuLic IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
REV..H 40.607
End Seal
CExposed Minimum Barrel Lenqth (Refer to Table) Diameter of hole is dependent upon the
type of escutcheon selected. Space must
be sealed to prevent condensation from
forming, per NFPA requirements.
HEATED SPACE
.A.
See Note
COLD SPACE
Exaggerated foraanty
TYPICAL SLEEVE AND SKIRT CONFIGURATION FOR EXAMPLE ONLY
FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS i 40.60
V36, K5.6 USTED
Dry Type Standard Spray .
Pendent, Intermediate Level Pendent
& Recessed Pendent
V3605 STANDARD RESPONSE
V3606 QUICK RESPONSE
JL 4 IY1
FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED
SKIRT
IMPORTANT INSTALLATION INFORMATION For detailed installation instructions, see publication 1-40.
No. 1 Victaulic Model V36 Series Dry sprinklers should be installed in accordance with NFPA
13. These sprinklers are to be installed using a pipe wrench applied to the outer tube.
When this is not possible, the proper sprinkler wrench may be used with extreme care for
lengths up to approximately 18. Excessive force may distort the frame thus destroying the
unit.
No. 2 Dry sprinklers MUST be installed only into the outlet of a cast or malleable iron tee.
No. 3 DO NOT install dry sprinklers into any couplings or threaded elbows. In addition, DO NOT
install dry sprinklers into any fitting that interferes with thread penetration. NOTE: The end
seal of the dry sprinkler MUST NOT bottom out in the fitting.
NOTE: The 'A" dimension of a dry sprinkler, which extends into a
freezer from a wet piping system, must take into account the wall or
ceiling thickness of the freezer. The minimum length of the dry sprinkler
should not be less than the lengths specified in the following table, plus
the thickness of the freezer's wall or ceiling ("A" = "C" + "D").
Refer to the drawing for a representation of the "A" dimension. DO NOT
attempt to modify dry sprinklers, since they are manufactured to this
specific "A" dimension.
The following table is used when the ambient temperature is maintained
between 40°F/4°C and 60°F/16°C around the wet piping system.
EXPOSED BARREL AMBIENT TEMPERATURE (°F/°C)
Ambient Temperature Exposed Minimum Barrel•1tTi1I,
inches/mm
r40
30
I_76
10
_
-12 203 25 0
0 12
-18 305 0
-10 14
-23 356 102 25
-20 14 6 3
-29 356 152 76
-30 16 i8 4
-34 406 203 102
-40 18 8 4
-40 457 203 102
-50 20 10 6
-46 508 254 152
-60 20 10 6
-51 508 254 152
NO I : taposea minimum oarrel iengtns are incluSive up to 30-mph/48-kprl wind
velocities
www.victaulic.com j4'tauiic' VIcTAULIc IS REGISTERED TRADEMARK OF vIcTAuLIc COMPANY. 6 2009 vlcTAuuc COMPANY. ALL RIGHTS RESERVED.
40.608 REV
V36, K56
Dry Type Standard Spray
Pendent, Intermediate Level Pendent
& Recessed Pendent
V3605 STANDARD RESPONSE
V3606 QUICK RESPONSE
WARRANTY
7 ~171
FLUSH SLEEVE AND
SKIRT
USTED
PLAIN BARREL INTERMEDIATE EXTENDED RECESSED
Refer to the Warranty section of the current Price List or contact Victaulic for details.
NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be
installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the
right to change product specifications, designs and standard equipment without notice and without
incurring obligations.
US & WORLD HEADQUARTERS CANADA CENTRAL AND SOUTH AMERICA
P.O. Box 31 905-884-7444 1-610-559-3300
Easton, PA 18044-0031 USA 905-884-9774 (fax) 1-610-559-3608 (fax)
4901 Kesslersville Road viccanada@victaulic.com vical@victaulic.com
Easton, PA 18040 USA EUROPE ASIA PACIFIC
1-800-PICK-VIC (1-800-742-5842) 32-9-381-15-00 86-21-54253300
1-610-559-3300 32-9-380-44-38 (fax) 86-21-54253671 (fax)
1-610-250-8817 (fax) viceuro@victaulic.be vicap@victaulic.com pickvic@victaulic.com
UNITED KINGDOM MIDDLE EAST www.victaulic.com
44 (0) 143831690 971-4-883-88-70
44 (0) 1438310699 (fax) 971-4-883-88-60 (fax)
viceuro@victaulic.be
UPDATED 11/2009
40.60 3123 REV H
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 6' 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED.
40.60
\4tauIIc