Loading...
HomeMy WebLinkAbout2175 SALK AVE; ; FA090044; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA090044 Job Address: 2175 SALK AV Status: ISSUED Permit Type: FALARM Applied 7/29/2009 Parcel No: 2120210200 Approved: 7/29/2009 Lot #: 0 Reference No.: Issued: 7/29/2009 PC #: Inspector: Project Title: VENTANA REAL - PH. 2 TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: STANDARD ELECTRONICS 9340 STEVENS RD SANTEE CA 619-596-9950 Owner: RIO SD PLAZA II MASTER LLC C/O NEWPORT NATIONAL CORPORATION 1525 FARADAY AVE #100 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 I Standard Electronics 9340 Stevens Rd. Santee, CA 92071 Ph# 619-596-9950 Fax# 619-596-8850 SUBMITTAL SHEET PROJECT: VENTANA REAL PHASE II June 29, 2009 June 30, 2009 covi VVIk-'s A l a EQUIPMENT FIRE ALARM ITEM QTY DESCRIPTION MODEL NO. DATA SHEET MICROPROCESSOR CONTROL PANEL - RED - SURFACE 1 1 MOUNTED BK-7100-2D FCI SFM #7165-694:219 REMOTE ANNUNCIATOR 2 1 LCD-7100 FCI SFM #7300-694:231 3 2 12 VOLT 7 AH SEALED LEAD ACID BATTERIES ES 7-12 MK BATTERY ADDRESSABLE MONITOR MODULE 4 43 SFM#7300-1073: 102 AMM-2F FCI ANALOG PHOTOELECTRIC SMOKE DETECTOR 5 5 ASD-PL2F FCI SFM#7272-0694:263 ANALOG HEAT DETECTOR 1900 6 1 ATD-HL2F FCI SFM#7270-0694:256 PLUG-IN BASE, FLANGED, 6.2 INCH DIAMETER SYSTEM 7 6 B210-LP SFM #7300-1653:109 SENSOR ADDRESSABLE PULL STATION 8 1 MS-7AF FCI SFM #7150-1073:102 ADDRESSABLE OUTPUT MODULE, FORM C RELAY 9 3 SFM #7300-0694:178 AOM-2RF FCI DUAL SYNC MODULE SYSTEM 10 1 SFM# 7300-1653:130 MDL3W SENSOR MULTI CANDELA HORN STROBE WALL MOUNT-RED SYSTEM 11 1 SFM #7125-1653:188 P2R SENSOR 6 FT 12AWG CEILING TIE WIRE WITH CLIP AND PIN JOBSITE 12 40 (NO CUT SHEET AVAILABLE) CEW1206CP SUPPLY RELAY MODULE 13 1 SFM# 7300-1004:101 RIC- 1 AIR PRODUCTS These plans have been reviewed for, apparent compliance with the current applicable cxles and standards in force in the jurisdiction. The owner or contractor may utilize this review in support of an application for a building ptrimiit with the express utxlerstanding that this review in uo way relieves the or oiiIractor or their piotessiminal engineer or architect for sole responsibility for full compliance with said codes and stdards. including the huildingeode or for any responsihilty for deficiencies. errors. omissions or negligence in these plans whether or not noted in this rcvte. Reviewer 0 RECOMMEND APPROVAL 0 RlCOMMENi) APPROVAL. AS NOTED I. -- ) - •I. :- LiLL i S go • CG&000~ Standard Electr=onic 9340 Stevens Rd. Santee, CA 92071 Ph# 619-596-9950 Fax# 619-596-8850 June 29, 2009 SUBMITTAL SHEET PROJECT: VENTANA REAL PHASE II EQUIPMENT FIRE ALARM ITEM QTY DESCRIPTION MODEL NO. DATA SHEET 16 AWG/ 2 CONDUCTOR - SOLID CONDUCTORS POWER LIMITED - OVERALL JACKETED - FIRE PROTECTIVE 14 1k #990 WEST PENN SIGNALING CABLE SFM #7161-859: 101 18 AWG/ 4 CONDUCTOR - SOLID CONDUCTORS POWER LIMITED - OVERALL JACKETED - FIRE PROTECTIVE 15 .5K #982 WEST PENN SIGNALING CABLE (ANNUNCIATOR, REMOTE) SFM #7161-0859:101 14 AWG/ 2 CONDUCTOR - SOLID CONDUCTORS POWER LIMITED - OVERALL JACKETED - FIRE PROTECTIVE 16 1K #994 WEST PENN SIGNALING CABLE SFM #7161-0859:101 WET RATED —16 AWG/2 CONDUCTOR— STRANDED CONDUCTORS POWER LIMITED - OVERALL JACKETED 17 .5k AQ225 WEST PENN - FIRE PROTECTIVE SIGNALING CABLE SFM #7161-859:101 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1703:105 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Gamewell-FCI, 12 Clintonville Road, Northford CT 06472 Contact: Brian Carlson (781)471-3000 Fax(781)471-3099 Brian.carlson@honeywell.com DESIGN: Models 7100-1, 7100-2, 7100-ID and 7100-2D fire alarm control units. Power-limited; non-coded, manual, automatic, local, auxiliary, central station, remote station, proprietary service, releasing device service, waterflow and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: BSM-1 1120-0783 Basic System Module BSM-2 1120-0781 Basic System Module BSM-1 D 1120-0782 Basic System Module with DACT BSD-2D 1120-0780 Basic System Module with DACT CAOM 1120-0763 Class A Option Module MCOM 1120-0761 Municipal Module PTRM 1120-0762 Printer Module 7100-EN-M-Door 1120-0779 Metal Door 7100-EN-Back Box 1120-0787 Back Box 7100-EN 1120-0787 Enclosure 7100-TXA 1120-0778 Transformer Assembly 7100-EN-P-Door 1120-0779 Plastic Door 7100-TXA-240 1120-0801 240V Transformer Assembly lNI-7100 INl-7100-UTP/-FO Intelligent Network Interface INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Inc. Label APPROVAL: Listed as fire alarm control units for use with separately listed electrically compatible initiating and indicating devices. These control units can generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL-864, *91h Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm), the maximum Retard/Rest/Restart period shall not exceed 30 seconds. FORMERLY: 7165-0694:219 *Updated 10-20-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0694:231 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fire Control Instruments, *16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 DESIGN: Model LCD-71 00 remote serial annunciator. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote annunciator for use with separately listed model 7100 fire alarm control unit (CSFM Listing No. 7165-0494:219). *Rev. 02-05-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division CALIFORNIA Di :PAftrMl::wi jr I:0RETY & FIRE PR0T1-.01,10N OFFICE OFT1 IE STAFF FIRE MARSHAL f:p: ENG NEL RING BUILDING MATERIALS LISTING iROG RN $\ SE W.V LISTING No. 7300-1703:102 Page 1 of 1 CATEGORY: Misc. Devices/Control unit Accessories LISTEE: Gamewell-FCI, 12 Clintonville Road, Northford CT 06472 Contact: Anthony J. Shalna (701) 471-3042 FAX Q, 1) 471-3099 0 DESIGN: Models AMM-4, *AMM4 F, AMM-2 and *AMM 2lfliionitor modules and Models AOM, AOM- Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION MARKING; APPROVAL: 0 XLF: FORMERLY: In accordance with [is lee's printed installation insiructions, applicable codes and ordina n c e s and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, electrical rting and UL label, Listed as accessories for use with separately listed compatible control units. System S e n s o r Mode! SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules 7300-1653:103 7300-0694:178 12-4-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff h a s r e v i e w e d t h e t e s t r e s u l t s and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operation a l r e q u i r e m e n t s o r i n s t a l l a t i o n criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sourc e s . Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - v LISTING SERVICE LISTING No. 7272-0694:263 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: Fire Control Instruments, 16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 DESIGN: Models ASD-PL2F, ASD-FILTREXF, ASD-PTL2F, and MCS-ACCLIMATE2F photoelectric smoke detector. Models ASD-PL2F and MCS-ACCLIMATE2F employ a 1350F supplement J11t gral heat sensor which only assists in a fire situation. This thermal circuitry is NOT ....... hëät thëët for detailed product description and operational considerations. INSTALLATION: . In accordanôe with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors when used in conjunction with listee's separately . listed Oompatiblé fire alarm control units and bases; Suitable for open areas with air velocity between 0-4000 fpm. Models ASD-PL2F, ASD-PTL2F, and MCS-ACCLIMATE2F also are suitable for installation inside ducts with a maximum air velocity of 4000 fpm NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread.quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-1653:123, Formerly 7272-1209:160 09-01-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed: This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. • Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING. - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0694:256 Page 1 of I CATEGORY: Heat Detector LISTEE: Fire Control Instruments, 16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 DESIGN: Models ATD-1-2, *ATD..L2F ATD-HL2 AND *ATD..HL2F (fixed temperature) and AID- RI-2, *ATD..RL2F (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to Iiste's data sheet fpr additionl detailed product description and operational idèFàfiôi. "TING: ATD-L2, *..L2F ATD-RL2, *RL2F = 1350 F fixed temperature ATD-HL2, *..HL2F = 1900 F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7270-1653:137 *Rev. 08-25-2005 h'.. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has revieWed the test results. and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. . Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CAL4 FJR1 satcft LISTING No. 7300-1653:109 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit AccessOries LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models B401, B401 B, 3401R, B401 BR, B401 BR-750, B401 R-750, 1340213, 640413, 1340413T, 1340613, 13501, 1350113, 14506587-002, 1350I131-1, 1350I13HT, 1340I13H, 131101-P, BIIORLP, ....................... B21.PLPdetector bases. Refer to d" -eet or etailed es ion an operatio66I considerations. INSTALLATION:. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or 'fr recommendation of the item listed: This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0694:261 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE: Fire Control Instruments,16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 DESIGN: Model MS-7AF dual action fire alarm pull box. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 41, XLF: 7150-0028:199 08-02-2005 ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Dote Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA Di l/.I:tirvII.Nr or: FORESTRY & IRE PRCYIEC:1ION OFF ICF OF TIlE STATE FIRE MARSHAl. F fl Y.. N1 I NLNFtING [H.JILDIN( M/TE.1flAL 1.1S1]14C. f(:'Nfi L 4N SR\tRE LISTING No. 7300-1703:102 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories USTEE: Gamewell-FCI, 12 Clintonville Road, Northiord CT 06472 Contact: Anthony J. Shalna (701) 471-3042 FAX (781) 471-3099 DESIGN: Models AMM-'i *AMM4F: AMM-2 and *AMM 21ionitor modules and Models AOM, AOM- . .... A0M2SFbritrOJ•iiodUIe. Refer to IisLees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with Fistees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical eating and UL label. APPROVAL: Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules. XLF: 7300-1653:103 FORMERLY: 7300-0694:178 12-4-07 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 10 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:130 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models MDL, MDLW sync modules. These modules are for use with listee's separately listed compatible horns and strobes. Refer to listee's data sheet for additional detailed product de§crip'jion,and operational considerations. RATING: 12or24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as sync modules for use with listee's separately listed compatible horns and strobes. NOTE: Formerly 7300-1209:179 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 10 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division .CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:188 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models CHSR and CHSW Chime/Strobes.., ..,.... .. ..................MpdelsP2R, P2 ,. ZRftapd,PVVRpjn/S.tr.ps two-wire.type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K' suffice models are suitable for outdoor applications at temperatures from T40 Degrees F to +151 Degrees F (-40 Degrees C to +66 Degrees C) and are rated NEMA 3R when used with the System Sensor weather proof back . boxes models *SAWBB (Wall) and *sA..wBBc(ceiling). Refer to listee's data sheet for additiOnal detailed product description and operational considerations. RATING: . Standard Horn/Strobes and Chime/Strobes 8— 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe liqhts suitable for hearing impaired applications when used with separately listed compatible fire alarm control units. Suitable for indoor or outdoor use, ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. "Rev. 04-22-2007 jw W. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or "p recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division .CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTiNG PROGRAM LISTING SERVICE LISTING No. 7300-1004:101 Page 1 of I CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Air Products and Controls Inc., 1749 East Highwood, Pontiac, Ml 48340 Contact: Richard Steele (248) 332-3900 FAX (248) 332-8807 DESIGN: Models MR-101/C, MR-104/C, MR-201/C, MR-201/CX, MR-204/6, MR-204/CX, PAM-11, PAM-2, PAM-2X, PAM-3, PAM-4, PAM-SD, RlC-1, RIC-2, *RlC3 *RIC4 *MRR1C..301 *MRRlc.305 *MR..Rr401 and *MR..RiC..4Q5 -elay modules. Models MR-101/C, -201/C ãhd -201/CX may employ suffix -R or -S. *TfMR:IC sêriEsrelayThddüles viII employ IT, IC, or ICIR suffixes. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: . Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. Rev. 03-01-2006jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test res u l t s and/or other data but does not make an independent verification of any claims. This listing is not an endors e m e n t o r ing should not be used to verify correct operational requirements or installation recommendation of the item listed. This list criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE LISTING No. 7161-0859:101 Page 1 of I CATEGORY: Cables-Fire Protective Signaling LISTEE: West Penn Wire, P0 Box 762, Washington PA 15301 Contact: Diane Kelley (724) 222-7060 FAX (724) 2291151* DESIGN: Types FPL and FPLP power limited fire protective signaling cable. Refer to listee's data .sheetfor dpt jld prpdçtdescriptiçn and qpional CQnsiderations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type, NEC rating and UL label APPROVAL: Listed as power-limited fire protective signaling cable. *Rev. 05-23-2005 ..' .° This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed th e t e s t r e s u l t s and/or other data but does not make an independent verification of any claims. This listing is not an endorse m e n t o r recommendation of the item listed. This listing should not be used to verify correct operational requirements or inst a l l a t i o n criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division FILE COPY STERLING CORPORATE — custom elevator interiors ROBERT PARKER, President 18 Via Di Nola, Laguna Niguel, CA 92677 Tel. (949) 495-1470 FAX (949) 495-7942 RICHARD O'REAR, Vice President 340W. 26th St., Ste I, National City, CA 91950 Tel. (619) 477-9654 FAX (619) 477-9634 GABRIEL T. YOLDI, Vice President 20 Arroyo Court, Hollister, CA 95023 Tel. (813) 636-9938 FAX (831) 636-9938 March 19, 2010 Mr. Bill Beckett TSA Contracting 9535 Waples St., Suite 200 San Diego, CA 92121 RE: Ventana Real Phase 11-2175 Salk Ave., Carlsbad, CA 92008 Dear Bill, May this letter serve as certification that the materials we have used for the car enclosure linings, i.e. metal, substrates, glass and fabric are Class A fire- rated and all wood surfaces have been treated with Flame Control No. 133A. All materials are in compliance with ASME A17.1 rule 204.2A which states; all materials used for the elevator cab interior lining are to have a flame spread rating of 0-75 and smoke developed of 0-450. Sincerely, Richard O'Rear Sterling Corporation FUNDAMENTALS OF FIRE ALARM SYSTEMS _ 72-31 F D°OO AA- Name of protected property: Address: :?/ 7S S c V r J i Qf(o Representative of protected property (name/phone): Authority having jurisdiction: 6 Address/telephone number: - (Q . Organization name/phone Representative name/phone Installer: (j'( Supplier: 4j (/4%'.. 595V Service organization: ; Location of record (as-built) drawings: - Location of operation and maintenance manuals: S Location of test reports: A contract for test and inspection in accordance with NFPA standard(s) ContractNo(s): Effective date: Expiration date: System Software system (executive) software revision level(s): Ptr (b Site-pecific software revision date: (c) Revision completed by: (name) (lam) 1. Type(s) of System or Service NFPA 72, Chapter 6— Local If alarm is transmitted to location(s) off premises list where received: NFPA 72, Chapter 8 - Remote Station Telephone numbers of organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are re-transmitted to public fire service communications centers or others, indicate locatio n a n d telephone numbers of the organization receiving alarm: Indicate how alarm is re-transmitted: NFPA 72, Chapter 8 - Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: - Trouble: If alarms are re-transmitted to public fire service communications centers or others, indicate location an d telephone numbers of the organization receiving alarm: Indicate how alarm is transmitted: NFPA 72, Chapter 8 - Central Station Prime contractor: 5 ys co c Central station location: 1P 410 - 9V' - '7 j?.5" (NFPA 72, 1 014) 2002 Edition H:WP6 1 \ FORMS \ NFPA 72 COMPLETION Signed: Organiz FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-32 Means of transmission of signals from the protected premises to the central station: - , McCulloh Multiplex One-way radio Digital alarm comiminicator T':o--way radic. Othcrs Means of transmission of alanijs to the public fire service communications center: System location: NFPA 72, Chapter 9 - Auxiliary Indicate type of connection: Local energy Shunt Parallel telephone Location of telephone number for receipt of signals: 2. Record of System Installation Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by 1oi , , 7/ 1 , includes the devices shown in 5 and 6, and has NFPA 72, Chapter/ tIci (O' W (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 19.6.2.3, is attached All operational features and functions of this system were tested by date 3/i 7/i ' and found to be operating in accordance with the requirements o NFPA 72, chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions O),her (s ec1f5'):___________________ Signed: i'/ .24-'--7,'.. Date:. Organization: Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA72, Table 6.6.1): Quantity: / Style: Class: /' Alarm-initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5): Quantity: Style: Class: MANUAL Manual stations Non-coded Transmitters Coded Addressable / Combination manual fire alarm and guard's tour coded stations (NFPA 72, 2 of 4) 2002 Edition H:WP6 I \ FORMS \ NFPA 72 COMPLETION 2 FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 AUTOMATIC Coverage: Conipltc Partial Selective (a) Smoke detectors Ion Photo Addressable (b) Duct detectors .3' 1 Ion Photo j / Addressable (c) Heat detectors ____ FT _______ RR 17T/RR RC Addressable 1 (d) Sprinkler water-flow indicators: Transmitters Non-coded Coded Addressable / (e) The &.arm verification feature is disabled or enabled , changed from - .> seconds to 4/) seconds. (0 Other (list): 6. Supervisory Signal-Initiating Devices and Circuits (use blanks to i n d i c a t e q u a n t i t y o f d e v i c e s ) GUAIW'S'TOUR Coded stations Non-coded stations ______ Compulsory guard's tour system comprised of transmitter stations and intermediate stations. NOTE: Combinatidn devices are recorded under 5(b), Manual, and 6(a), G u a r d ' s T o u r . SPRINKLER SYSTEM Check if provided (a) ?- Valve supervisory switches (b)_ Building temperature points (c) - Site water temperature points — Site water supply level points Electric fire pump: (é) Fire pump power (f) Fire pump running (g) Phase reversal Engine-Driven Fire Pump: - Selector in auto position Engine or control panel trouble Fire pump running Engine -Driven Generator: Selector in auto position Control panel trouble Transfer switches Engine running Other supervisory function(s) (specify): Annunciator(s) Number: I Type: 1- - tO Location: LC4 Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 — Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: Quantity and the class of notification appliance circuits connected to syste m ( s e e N P F A 7 2 , T a b l e 6 . 7 ) : Quantity: Style: Class: (NFPA 72,3 of 4) 2002 Edition H:WP6I \ FOS \ NFPA 72 COMPLETION FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-34 Types and quantities of notification appliances installed: Bells With Visible spcakcrs Wih Visible Horns With Visible I Chimes With Visible Other: With Visible Visible appliances without audible: 9. System Power Supplies - Fire Alarm Control Panel: Nominal voltage: j2 V/k_- Current rating: Over-current protection: Type: flr€-k -z_ Current Rating: O Location: /'-, L_ Secondary (standby): Storage battery: y.iz - Amp-hour rating /1 1-;,- Calculated capacity to drive system, in hours: Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency system used as backup to primary power supply: Emergency System described in NFPA 70, Article 700: 10. Comments: Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA stan d a r d ( s ) : System deviations from the referenced NFPA standard(s) are: for installation contractor/supplier / (title) (signed) for olarni service company (title) (date) central Station (title) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jur i s d i c t i o n ) : / / r7I)o tO III (NFPA 72, 4 of 4) 2002 Edition H:WP61 \ FORMS \NFPA 72 COMPLETION 4