HomeMy WebLinkAbout2175 SALK AVE; ; AS090039; PermitCity of Carlsbad Sprinkler Permit Permit No: AS090039 Job Address: 2175 SALK AV Status: ISSUED Permit Type: SPRINK Applied 4/29/2009 Parcel No: 2120210200 Approved: 4/29/2009 Lot #: 0 Reference No.: Issued: 4/29/2009 PC #: Inspector: Project Title: VENTANA REAL II Applicant: MILLENNIUM FIRE PROTECTION SUITE F 101 COPPERWOODWY OCEANSIDE, CA 760-722-2722 Owner: RIO SD PLAZA II MASTER LLC C/O NEWPORT NATIONAL CORPORATION 1525 FARADAY AVE #100 CARLSBAD CA Fees ($) Add'I Fees ($) ( Total ($) Balance ($) 195 0 195 0 Parsley Consulting 350 West 9& Avenue, Suite 206 Escondido, California 92025-5053 Telephone (760) 745-6181 Fax(760) 745-0537 April 23, 2009 Mr. James Weigand City of Carlsbad Fire Department Office of Fire Protection Services 1635 Faraday Avenue Carlsbad, California 92008 Subject: Plan Review for Ventana Real II, 2175 Salk Avenue, Carlsbad, CA Dear Mr Weigand: We have reviewed the submittal as prepared by Millennium Fire. Based on our review it is our opinion that the submittal is in substantial conformance with the applicable codes and standards in force at this time, including local adopted ordinances. Further submittal should not be required. Sincerely, Xth EY CONSULT}NG W. agone9ET Office Manager End (1) Working Drawings - 3 sets Hydraulic Calculations - 3 sets Review Comments - 1 set Note: A copy of this letter has been transmitted via fax to Millennium Fire on April 23, 2009 file:\S:\Shared Files\RE VIE WS\Rev2O9136.002.wpd Ventana Real II Review Comments Page 2 of 2 Review Comments Ventana Real II, 2175 Salk Avenue, Carlsbad, CA 1. If Ames 3000ss is provided with monitored OS&Y valves, which the detail suggests, then consideration should be given to eliminating the butterfly valve in the riser. This represents another potential source of impairment. Designers' response to this comment on our first review is that the butterfly will remain as they had not be able to confirm monitoring of the OS&Y valves on the Ames 3000ss. NFPA- 13, 2002 edition, section 8.15.1.1.2, regarding supervision, reads: i. 8.15.1.1.2.1 Valves on connections to water supplies, sectional control and isolation valves, and other valves in supply pipes to sprinklers and other fixed water-based fire suppression systems shall be supervised by one of the following methods: Central station, proprietary, or remote station signaling service Local signaling service that will cause the sounding of an audible signal at a constantly attended point Valves locked in the correct position Valves located within fenced enclosures under the control of the owner, sealed in the open position, and inspected weekly as part of an approved procedure Field verify that at least one of these methods is used on the OS&Y valves, and, if the supervision is per methods (1) or (2) above, consider eliminating the butterfly valve at the base of the riser. No resubmittal would be required. 2. Verify that the elevator shafts do not meet the exceptions for requiring sprinkler protection in NFPA-13, section 8.14.5.2. 3. Sprinkler near east stair appears to have discharge blocked by adjacent steel framing member. Review and revise if obstructed. 4. Field verify that Detail #3 on sheet 5 is only within 6" of the chord panel point. 11 I D I"" ~twll .ç in uc' (t.ii , 0, jlneif this uj : %i the C. .0111fact, I rc''' "ect fill I''' 110 nal Cfl C W full, s "lilt , 111V i0v .00111 'elialic t %IC%U r(or0flU I CtCflhc O 'P lii&. W ______-.--- plA 1 t40 xS \Rirc MILLENNIUM FIRE PROTECTION CRP 101 COPPERWOOD WAY SUITE H OCEANSIDE, CA 92058 760-722-2722 Job Name : Ventana Real II Drawing : FP-2 Location : 2175 Salk Ave., Carlsbad, CA Remote Area : 1 Contract : 08-055 Data File : 08-055-VENTANA 1stWNDWr3.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CRP Ventana Real II Page 1 Date 4/20/09 HYDRAULIC CALCULATIONS for Project name: Ventana Real II Location: 2175 Salk Ave., Carlsbad, CA Drawing no: FP-2 Date: 4/20/09 Design Remote area number: 1 Remote area location: 1 ST FLOOR NORTHEAST LOBBY Occupancy classification: PER SCHI RMER ENG. REPORT Density: .10 - Gpm/SqFt Area of application: 425 - SqFt Coverage per sprinkler: 225 - SqFt Type of sprinklers calculated: SSU 5.6k, WINDOW SPK @ 25P51 No. of sprinklers calculated: 7 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams) 437.4 - GPM @ 49.2 - Psi Type of system: WET GRID Volume of dry orpreaction system: N/A - Gal Water supply information Date: 12/10/08 Location: 2175 SALK AVE., CARLSBAD, CA Source: PERFORMED BY MILLENNIUM FIRE PROTECTION Name of contractor: Millenium Fire Protection Corp Address: 101 Copperwood Way, Ste H, Oceanside, CA 92058 Phone number: 760-722-2722 Name of designer: J. VAN KOLKEN Authority having jurisdiction: CAR LS BAD FIRE DEPT. Notes: (Include peaking information or gridded systems here.)10% DEDUCTION IN WATER SUPPLY DATA PRIOR TO ENTRY INTO CALCULATION. A GENERIC BACKFLOW (DCDA) LOSS OF 5 lbs HAS BEEN ADDED TO CALC. WORST CASE FLOW THROUGH SITE LOOP WAS USED IN THIS CALC. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) MILLENNIUM FIRE PROTECTION CRP Page 2 Ventana Real II Date 4/20/09 City Water Supply: Demand: Cl - Static Pressure : 54 Dl - Elevation : 12.127 C2 - Residual Pressure: 49.5 D2 - System Flow : 190.042 C2 - Residual Flow : 1177 D2 - System Pressure : 50.978 Hose(Adj City) ______ Hose SrDemand) : 250 D3 - System Demand : 440.042 Safety Margin : 2.293 150 -- 140 130 P 120 R110 E10° S 90 80 u 70 R6° - ____ _____ ______ ________ C2 E 50 40 30 20 10 S D1 I I I I I I I 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N" 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary MILLENNIUM FIRE PROTECTION CRP Page 3 Ventana Real II ----------------- Date 4/20/09 Fitting Legend Abbrev. Name % ~ 1 11/4 11/2 2 2V2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 MILLENNIUM FIRE PROTECTION CRP Ventana Real II Page 4 Date 4/20/09 SUPPLY ANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SRC 54.0 49.5 1177.0 53.271 440.04 50.978 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes WD 10.0 5.6 25.0 28.0 SPK 10.0 5.6 16.14 22.5 Wi 11.0 5.47 26.9 28.37 K=K @ HD W2 11.0 5.47 26.93 28.39 K=KHD 95 11.0 27.43 96 11.0 28.93 W3 11.0 5.47 26.2 28.0 K=K © HD W4 11.0 5.47 26.21 28.01 K=K @ HO 90 11.0 5.45 20.13 24.45 K=K @HO1 91 10.0 5.6 21.13 25.74 92 10.0 5.6 23.4 27.09 93 11.0 22.59 94 11.0 25.14 100 11.0 30.65 101 11.0 30.66 102 11.0 30.7 103 11.0 30.76 104 11.0 30.82 110 11.0 29.83 111 11.0 29.93 113 11.0 30.25 114 11.0 30.35 115 11.0 30.47 116 11.0 30.48 124 11.0 33.16 123 11.0 33.65 122 11.0 33.79 121 11.0 33.84 120 11.0 33.86 105 11.0 30.94 106 11.0 31.0 107 11.0 31.02 130 11.0 34.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 200 MILLENNIUM FIRE PROTECTION CRP Page 5 Ventana Real II Date 4/20/09 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 131 11.0 34.0 132 11.0 34.01 133 11.0 34.01 71 11.0 34.01 134 11.0 34.02 72 11.0 34.08 135 11.0 33.98 136 11.0 33.96 TR 11.0 34.28 BR 0.0 39.53 UG -6.0 42.2 BFP 1.0 39.43 UG1 -7.0 46.2 UG2 -17.0 50.85 SRC -17.0 50.98 250.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Page 6 Ventana Real II Date 4/20/09 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf WD 10 5.60 28.00 1 iT 5.762 2.000 120 25.000 to 0.0 5.762 -0.433 HD 11 28:0 1.08 0.0 7.762 0.2104 1.633 Vel = 9.81 0.0 HP 28.00 - 26.200 K Factor = 5.47 SPK 10 5.60 22.50 1 iT 5.762 1.500 120 16.143 to 1E 2.305 8.067 -0.433 HD1 11 22.5 1.08 0.0 9.567 0.1404 1.343 Vel = 7.88 0.0 HD1 22.50 17.053 KFactor= 5.45 *SPK1 Wi ii 5.47 28.37 1.5 0.0 1.000 120 26.903 K= K@ HO to 0.0 0.0 0.0 W2 11 28.371:639 0.0 1.000 0.0280 0.028 Vel = 4.31 W2 11 5.47 28.39 1.5 1E 4.363 0.500 120 26.931 K=K@HD to 0.0 4.363 0.0 95 ii 56.76 1.639 0.0 4.863 0.1020 0.496 Vel = 8.63 95 11 0.0 1.5 iT 8.727 6.000 120 27.427 to 0.0 8.727 0.0 96 11 56.76 1.639 0.0 14.727 0.1020 1.502 Vel = 8.63 96 11 0.0 2 iT 13.639 23.750 120 28.929 to 0.0 13.639 0.0 110 11 56.76 2.203 0.0 37.389 0.0242 0.904 Vel = 4.78 0.0 110 56.76 29.833 KFactor= 10.39 *SPK2 W3 11 5.47 28.00 1.5 0.0 0.500 120 26.200 K= K@ HO to 0.0 0.0 0.0 W4 11 28.0 1.728 0.0 0.500 0.0220 0.011 Vel = 3.83 W4 11 5.47 28.01 1.5 iT 11.29 25.750 120 26.211 K=K@ HO to 2E 11.29 22.580 0.0 lii ii 56.01 1.728 0.0 48.330 0.0769 3.718 Vel = 7.66 0.0 lii 56.01 29.929 KFactor= 10.24 *SPK3 90 ii 5.45 24.45 1 0.0 15.000 120 20.130 K=K@HO1 to 0.0 0.0 0.0 93 11 24.45 1.08 0.0 15.000 0.1637 2.456 Vel = 8.56 0.0 93 24.45 22.586 K Factor = 5.14 91 10 5.60 25.74 1 iT 5.762 4.750 120 21.126 to 0.0 5.762 -0.433 93 11 25.74 1.08 0.0 10.512 0.1801 1.893 Vel= 9.01 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Ventana Real II Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe Node2 Elev2 Fact Qt Act Eqv, Ln. Total Pf/Ft Pf Page 7 Date 4/20/09 Notes 0.0 93 . 25.74 - 22.586 KFactor= 5.42 92 10 5.60 27.09 1 iT 5.762 5.200 120 23.402 to 0.0 5.762 -0.433 94 11 27.09 1.08 0.0 10.962 0.1980 2.170 Vel 9.49 0.0 94 27.09 25.139 K Factor = 5.40 93 11 50.18 1.25 0.0 15.000 120 22.586 to 0.0 0.0 0.0 94 11 50.18 1.408 0.0 15.000 0.1702 2.553 Vel = 10.34 94 11 27.10 1.25 iT 6.617 7.500 120 25.139 to 0.0 6.617 0.0 116 11 77.28 1.408 0.0 14.117 0.3783 5.341 Vel= 15.92 0.0 116 77.28 30.480 K Factor = 14.00 *GRlD1 100 11 -27.66 2 2T 27.277100.750 120 30.651 to 0.0 27.277 0.0 11011 -27.66 2.203 0.0 128.027 -0.0064 -0.818 Vel = 2.33 0.0 110 -27.66 29.833 K Factor = -5.06 101 11 -26.09 2 2T 27.277100.750 120 30.663 to 0.0 27.277 0.0 111 11 -26.09 2.203 0.0 128.027 -0.0057 -0.734 Vel = 2.20 0.0 111 -26.09 29.929 K Factor = -4.77 102 11 -19.95 2 2T 27.277100.750 120 30.700 to 0.0 27.277 0.0 113 11 -19.95 2.203 0.0 128.027 -0.0035 -0.447 Vel = 1.68 0.0 113 -19.95 30.253 KFactor= -3.63 103 11 -15.58 2 2T 27.277115.000 120 30.759 to 6E 40.916 68.193 0.0 114 11 -15.58 2.203 0.0 183.193 -0.0022 -0.405 Vel = 1.31 0.0 114 -15.58 30.354 KFactor= -2.83 104 11 -18.64 2 iT 13.639100.750 120 30.820 to 0.0 13.639 0.0 115 11 -18.64 2.203 0.0 114.389 -0.0031 -0.352 Vel = 1.57 0.0 115 -18.64 30.468 K Factor = -3.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Ventana Real II Nodel Elevl K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf Page 8 Date 4/20/09 Notes *OFFSET 110 11 29.10 2 0.0 13.660 120 29.833 to 0.0 0.0 0.0 111 11 29.1 2.203 0.0 13.660 0.0070 0.096 VeI= 2.45 111 11 29.92 2 0.0 12.500 120 29.929 to 0.0 0.0 0.0 113 11 59.02 2.203 0.0 12.500 0.0259 0.324 VeI= 4.97 113 11 -19.95 2 0.0 8.330 120 30.253 to 0.0 0.0 0.0 114 11 39.07 2.203 0.0 8.330 0.0121 0.101 Vel = 3.29 114 11 -15.58 2 iT 13.639 10.500 120 30.354 to 0.0 13.639 0.0 115 11 23.49 2.203 0.0 24.139 0.0047 0.114 Vel = 1.98 115 11 -18.64 2 2E 13.639 32.250 120 30.468 to 0.0 13.639 0.0 116 11 4.85 2.203 0.0 45.889 0.0003 0.012 Vel = 0.41 116 11 77.27 2 iT 13.639 35.600 120 30.480 to 1E 6.819 20.458 0.0 124 11 82.12 2.203 0.0 56.058 0.0478 2.682 VeI= 6.91 124 11 -29.20 2 iT 13.639 9.500 120 33.162 to 0.0 13.639 0.0 123 11 52.92 2.203 0.0 23.139 0.0213 0.492 Vel = 4.45 123 11 -15.73 2 0.0 12.000 120 33.654 to 0.0 0.0 0.0 -122 11 37.19 2.203 0.0 12.000 0.0110 0.132 Vel = 3.13 122 11 -14.01 2 0.0 12.000 120 33.786 to 0.0 0.0 0.0 121 11 23.18 2.203 0.0 12.000 0.0047 0.056 Vel = 1.95 121 11 -11.89 2 0.0 12.000 120 33.842 to 0.0 0.0 0.0 120 11 11.29 2.203 0.0 12.000 0.0012 0.014 Vel = 0.95 0.0 120 11.29 33.856 KFactor= 1.94 *G RI D2 120 ii 11.29 2 2T 27.277 94.000 120 33.856 to 0.0 27.277 0.0 130 11 11.29 2.203 0.0 121.277 0.0012 0.148 Vel = 0.95 0.0 130 11.29 34.004 KFactor= 1.94 121 ii 11.90 2 2T 27.277 94.000 120 33.842 to 0.0 27.277 0.0 131 11 11.9 2.203 0.0 121.277 0.0013 0.162 Vel = 1.00 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations.- Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Page 9 Ventana Real II Date 4/20/09 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 0.0 131 11.90 34.004 KFactor= 2.04 122 11 14.01 2 2T 27.277 94.000 120 33.786 to 0.0 27.277 0.0 132 11 14.01 2.203 0.0 121.277.. 0.0018 0.221 Vel = 1.18 0.0 132 14.01 34.007 KFactor= 2.40 123 11 15.73 2 2T 27.277104.500 120 33.654 to 4E 27.277 54.554 0.0 133 11 15.73 2.203 0.0 159.054 0.0023 0.358 Vel = 1.32 0.0 133 1513 . 34.012 KFactor= 2.70 124 11 29.20 2 2T 27.277 94.000 120 33.162 to 0.0 27.277 0.0 134 11 29.2 2.203 0.0 121.277 0.0071 0.857 Vel = 2.46 0.0 134 29.20 34.019 KFactor= 5.01 *GRlD3 105 11 36.38 2 2T 27.277259.500 120 30.938 to 0.0 27.277 0.0 135 11 36.38 2.203 0.0 286.777 0.0106 3.042 Vel = 3.06 0.0 135 36.38 33.980 KFactor= 6.24 106 11 35.85 2 2T 27.277259.500 120 31.001 to 0.0 27.277 0.0 136 11 35.85 2.203 0.0 286.777 0.0103 2.962 Vel = 3.02 0.0 136 35.85 33.963 KFactor= 6.15 107 11 35.70 2 2T 27.277259.500 120 31.020 to 0.0 27.277 0.0 137 11 35.7 2.203 0.0 286.777 0.0102 2.938 Vel 3.00 0.0 137 35.70 33.958 KFactor= 6.13 *FLOAT 100 11 27.66 3 0.0 13.600 120 30.651 to 0.0 0.0 0.0 101 11 27.66 3.314 0.0 13.600 0.0009 0.012 Vel = 1.03 101 11 26.09 3 0.0 12.500 120 30.663 to 0.0 0.0 0.0 102 11 53.75 3.314 0.0 12.500 0.0030 0.037 Vel = 2.00 102 11 19.94 3 0.0 11.000 120 30.700 to 0.0 0.0 0.0 103 11 73.69 3.314 0.0 11.000 0.0054 0.059 Vel = 2.74 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Page 10 Ventana Real II Date 4/20/09 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 103 11 15.59 3 0.0 8.000 120 30.759 to 0.0 0.0 0.0 104 11 89.28 3.314 0.0 8.000 0.0076 0.061 Vel = 3.32 104 11 18.64 3 0.0 10.833 120 30.820 to 0.0 0.0 0.0 105 11 107.92 3.314 0:0 10.833 0.0109 0.118 Vel= 4.01 105 11 -36.38 3 0.0 12.500 120 30.938 to 0.0 0.0 0.0 106 ii 71.54 3.314 0.0 12.500 0.0050 0.063 Vel= 2.66 106 11 -35.84 3 0.0 13.000 120 31.001 to 0.0 0.0 0.0 107 11 35.7 3.314 0.0 13.000 0.0015 0.019 Vel = 1.33 0.0 107 35.70 31.020 K Factor = 6.41 *MAIN 130 11 11.29 4 0.0 12.000 120 34.004 to 0.0 0.0 0.0 131 11 11.29 4.31 0.0 12.000 0 0.0 Vel = 0.25 131 11 11.89 4 0.0 12.000 120 34.004 to 0.0 0.0 0.0 132 11 23184.31 0.0 12.000 0.0002 0.003 Vel = 0.51 132 11 14.01 4 0.0 12.000 120 34.007 to 0.0 0.0 0.0 133 11 37.19 4.31 0.0 12.000 0.0004 0.005 VeI= 0.82 133 11 15.73 4 0.0 3.500 120 34.012 to 0.0 0.0 0.0 71 11 ç92.31 0.0 3.500 0.0006 0.002 Vel = 1.16 71 11 0.0 4 0.0 6.000 120 34.014 to 0.0 0.0 0.0 134 11 52.92 4.31 0.0 6.000 0.0008 9.005 Vel = 1.16 134 11 29.20 4 iT 27.874 5.600 120 34.019 to 0.0 27.874 0.0 72 11 82.12431 0.033.474 0.0018 0.061 VeI= 1.81 72 11 -190.04 4 iT 27.874 5.250 120 34.080 to 0.0 27.874 0.0 135 11 -107.92 4.31 0.0 33.124 -0.0030 -0.100 Vel= 2.37 135 11 36.38 4 0.0 12.500 120 33.980 to 0.0 0.0 0.0 136 - 11 -71.54 4.31 - 0.0 12.500 -0.0014-0.017 Vel = 1.57 136 11 35.84 4 0.0 13.000 120 33.963 to 0.0 0.0 0.0 137 11 -35.7 4.31 0.0 13.000 -0.0004 -0.005 Vel = 0.79 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 1 MILLENNIUM FIRE PROTECTION CRP Page 11 Ventana Real II Date 4/20/09 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe Notes Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 0.0 137 -35.70 33.958 KFactor= -6.13 *FEED 72 11 190.04 4 1E 13.937 9.500 120 34.080 to 0.0 13.937 0.0 TR 11 190.04 4.31 0.0 23.437 0.0086 0.202 Vel = 4.18 TR 11 0.0 4 lB 16.724 11.500 120 34.282 to 2E 27.874 44.598 4.764 BR 0 190.04 4.31 0.0 56.098 0.0086 0.483 Vel = 4.18 0.0 BR 190.04 39.529 K Factor = 30.23 *UG BR 0 190.04 6 2E 40.168 25.000 140 39.529 to 0.0 40.168 2.599 UG -6 190.04 6.16 0.0 65.168 0.0011 0.073 Vel = 2.05 UG -6 0.0 6 2E 35.786132.000 150 42.201 to iT 38.342 74.128 -3.032 BFP 1 190.04 5.86 0.0 206.128 0.0013 0.263 Vel = 2.26 BFP 1 0.0 6 2E 35.786 45.000 150 39.432 to iT 38.342 77.962 6.615 * Fixed loss 3.15 UG1 -7 190.04 5.86 1G 3.834122.962 0.0013 0.157 Vel = 2.26 iZaf 0.0 UG1 -7 0.0 8 1E 22.555883.000 150 46.204 to 1G 5.012 27.567 4.331 UG2 -17 190.04 7.68 0.0 910.567 0.0003 0.311 Vel = 1.32 UG2 -17 0.0 8 iT 43.857281.000 150 50.846 to 1G 5.012105.257 0.0 SRC -17 190.04 7.68 3F 33.833386.257 0.0003 0.132 Vel = 1.32 1E 22.555 250.00 Qa = 250.00 SRC 440.04 50.978 K Factor = 61.63 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CRP 101 COPPERWOOD WAY SUITE H OCEANSIDE, CA 92058 760-722-2722 Job Name Ventana Real II Drawing : FP-4 Location : 2175 Salk Ave., Carlsbad, CA Remote Area : 1 Contract : 08-055 Data File : 08-055-VENTANA 3RDFLRr2-1 .WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CRP Page 1 Ventana Real II Date 4/20/09 HYDRAULIC CALCULATIONS for Project name: Ventana Real II Location: 2175 Salk Ave., Carlsbad, CA Drawing no: FP-4 Date: 4/20/09 Design Remote area number: 1 Remote area location: 3RD FLOOR MID. SOUTH AREA Occupancy classification: ORDINARY HAZARD I Density: .15 - Gpm/SqFt Area of application: 1073 - SqFt Coverage per sprinkler: 130 - SqFt Type of sprinklers calculated: SSU 5.6k No. of sprinklers calculated: 10 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 446.1-GPM @47.4-Psi Type of system: WET GRID Volume of dry or preaction system: N/A - Gal Water supply information Date: 12/10/08 Location: 2175 SALK AVE., CARLSBAD, CA Source: PERFORMED BY MILLENNIUM FIRE PROTECTION Name of contractor. Millenium Fire Protection Corp Address: 101 Copperwood Way, Ste H, Oceanside, CA 92058 Phone number: 760-722-2722 Name of designer: J. VAN KOLKEN Authority ha ving jurisdiction: CAR LS BAD FIRE DEPT. Notes: (Include peaking information or gridded systems here.)10% DEDUCTION IN WATER SUPPLY DATA PRIOR TO ENTRY INTO CALCULATION. 34% AREA REDUCTION DUE TO THE USES OF QR SPKs (MIN. 990 SQFT) A GENERIC BACKFLOW (DCDA) LOSS OF 5 lbs HAS BEEN ADDED TO CALC. WORST CASE FLOW THROUGH SITE LOOP WAS USED IN THIS CALC. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) MILLENNIUM FIRE PROTECTION CRP Ventana Real II Page 2 Date 4/20/09 City Water Supply: Demand Cl - Static Pressure : 54 DI -'Elevation : 24.254 C2 - Residual Pressure: 49.5 D2 - System Flow : 196.085 C2 - Residual Flow : 1177 D2 - SrA stem Pressure : 47.014 Hose djCity ______Hose Demand) : 250 D3 - System Demand : 446.085 Safety Margin : 6.239 150 140 130 p120 R110 E10° S90 S 80 U7° R6° C2 " n-' -° E '- L; 40 E3 30 20 ° 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N A 1.85) Computer Programs by Hydratec inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary MILLENNIUM FIRE PROTECTION CRP Page 3 - Ventana Real II Date 4/20/09 Fitting Legend - Abbrev. Name 1/2 % 1 1¼ 1½ 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 MILLENNIUM FIRE PROTECTION CRP Page 4 Ventana Real II Date 4/20/09 SUPPLY ANAL YSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure SRC 54.0 49.5 1177.0 53.252 446.08 47.014 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes SPG 40.0 5.6 12.13 19.5 16 40.0 13.96 1 40.0 5.6 12.34 19.67 2 40.0 5.6 12.27 19.62 3 40.0 5.6 12.26 19.61 4 40.0 5.6 12.27 19.62 5 39.0 5.44 12.85 19.5 15 40.0 13.99 6 40.0 5.6 12.31 19.65 7 40.0 5.6 12.25 19.6 8 40.0 5.6 12.24 19.59 9 40.0 5.6 12.24 19.59 100 40.0 5.6 12.3 19.64 12 40.0 14.62 13 40.0 14.58 14 40.0 14.47 11 40.0 14.64 10 40.0 14.64 40 40.0 15.72 41 40.0 15.72 42 40.0 15.72 44 40.0 15.94 45 40.0 15.63 46 40.0 15.4 47 40.0 15.38 30 39.0 15.03 31 39.0 15.02 32 39.0 15.0 33 39.0 14.95 34 39.0 14.86 35 39.0 14.72 50 39.0 16.2 51 39.0 16.2 K=K©HD Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 MILLENNIUM FIRE PROTECTION CRP Page 5 Ventana Real II Date 4/20/09 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 52 39.0 16.21 53 39.0 16.25 55 39.0 16.12 56 39.0 16.08 54 39.0 16.44 60 39.0 16.58 70 11.0 29.07 71 11.0 29.75 72 11.0 30.11 TR 11.0 30.32 BR 0.0 35.6 UG -6.0 38.28 BFP 1.0 35.52 UG1 -7.0 42.21 UG2 -17.0 46.87 SRC -17.0 47.01 250.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Vel= 4.32 Vel = 2.66 13.639 70.000 0.0 13.639 0.0 83.639 II 'I' '1* .11 8.0011 120 13.991 0.0 -0.0200_-1.676 120 12.315 0.0 -0.0082 -0.066 5.762 1.000 120 12.125 0.0 5.762 0.0 0.0 6.762 0.10780.729 Vel= 6.83 ______ 12.854 KFactor=_5.44 13.639 70.000 120 13.963 0.0 13.639 0.0 0.0 83.639-0.0195-1.627Vel = 4.25 0.0 8.000 120 12.336 0.0 0.0 0.0 0.0 8.000 -0.0079 -0.063 Vel _=2.59 0.0 8.000 120 12.273 0.0 0.0 0.0 0.0 8.000 -0.0011 -0.009 Vel = 0.94 0.0 8.000 120 12.264 0.0 0.0 0.0 0.0 8.000 0.0006 0.005 Vel = 0.71 13.639 9.500 120 12.269 0.0 13.639 0.433 0.023.139 0.00660.152 Vel = 2.36 13.639143.000 120 12.854 K=K@HD 13.639 27.278 -0.433 0.0 170.278 0.0174 2.963 Vel = 4.00 15.384 KFactor= 12.12 11.0 8.000 II, III IT. ilol 8.500 0.0 8.500 120 12.249 0.0 -0.0014_-0.011 Vel =1.02 120 12.238 0.0 0.0006 0.005Vel = 0.63 120 12.243 0.0 0.0061 0.052 Vel = 2.28 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Ventana Real II Nodel EIev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf Page 6 Date 4/20/09 Notes SPG 40 5.60 19.50 1 iT to HD 40 19.5 1.08 0.0 HD 19.50--- 16 40 -50.48 2 IT to 1 40 - -50.48 2.203 1 40 5.60 19.67 2 to 2 40 -30.812.203 2 40 5.60 19.62 2 to 3 40 -11.192.203 3 40 5.60 19.61 2 to 4 40 8.422.203 4 40 5.60 19.61 2 2E to 5 39 28.032.203 5 39 5.44 19.50 2 IT to 2E 47 40 47.53 2.203 0.0 47 47.53 *LINE2 15 40 -51.31 2 iT to 6 40 -51.312.203 6 40 5.60 19.66 2 to 740 -31.652.203 7 40 5.60 19.59 2 to 8 40 -12.062.203 8 40 5.60 19.60 2 to 940 7.542.203 9 40 5.60 19.59 2 to 100 40 27.13 2.203 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 15.721 KFactor=5.10 120 14.585 0.0 0.0043 1.356 VeI= 1.88 15.941KFactor = 5.60--- 120 14.474 0.0 0.0033 1.160 Vel = 1.63 15.634 K Factor = 4.90 120 14.637 0.0 0.0035 1.079 VeI= 1.68 15.716 K Factor = 5.04 120 14.643 0.0 0.0035 1.072 Vel = 1.67 15.715 K Factor = 5.02 40 -19.90 2 iT 13.639 1.000 120 14.643 0.0 13.639 0.433 39 -19.9 2.203 0.0 14.639 -0.0035 -0.051 Vel _1.67 0.0 -19.90 15.025 KFactor= -5.13 40 -19.97 2 iT 13.639 1.000 120 14.637 0.0 13.639 0.433 39 -19.97 2.203 0,0 14.639 -0.0036 -0.052 Vel = 1.68 0.0 42 13 to 44 44 14 to 45 45 11 to 41 41 10 to 40 40 *RN 10 to 30 30 11 to 31-- 0.0 20.21 22.34 2 2T 27.277233.250 8E 54.555 81.832 22.342.203 0.0 315.082 0.0 22.34 19.37 2 2T 27.277275.500 7E 47.735 75.012 19.37 2.203 0.0 350.512 0.0 19.37 19.97 2 2T 27.277254.000 4E 27.277 54.554 19.97 2.203 0.0 308.554 0.0 19.97 19.90 2 2T 27.277254.000 4E 27.277 54.554 19.9 2.203 0.0 308.554 0.0 19.90 40 40 40 40 40 40 40 40 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Page 7 Ventana Real II Date 4/20/09 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 100 40 5.60 19.64 2 iT 13.639143.000 120 12.295 to 4E 27.277 40.916 0.0 46 40 46.77 2.203 0.0 183.916 0.0169 3.106 Vel = 3.94 0.0 46 46.77 15.401K Factor =11.92 *LINES - 12 40 20.21 2 2T 27.277254.000 120 14.618 to 4E 27.277 54.554 0.0 4240 20.212.2030.0 308.554 0.0036 1.103 Vel = 1.70 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Page 8 Ventana Real II Date 4/20/09 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 31 -19.97 15.018 KFactor= -5.15 12 40 -20.21 2 iT 13.639 1.000 120 14.618 to 0.0 13.639 0.433 32 39 -20.21 2.203 0.0 14.639 -0.0036 -0.052 Vel = 1.70 0.0 32 -20.21 14.999 KFactor= -5.22 13 40 -22.34 2 iT 13.639 1.000 120 14.585 to 0.0 13.639 0.433 33 39 -22.34 2.203 0.0 14.639 -0.0043 -0.063 Vel = 1.88 0.0 33 -22.34 14.955 K Factor = -5.78 14 40 -19.37 2 iT 13.639 1.000 120 14.474 to 0.0 13.639 0.433 34 39 -19.37 2.203 0.0 14.639-0.0033-0.048Vel =1.63 0.0 34 -19.37 14.859 KFactor= 15 40 51.31 2 1 13.639 1.000 120 13.991 to 0.0 13.639 0.433 35 39 51.31 2.2030.014.639 0.02010.294 Vel =4.32 0.0 35 51.31 14.718 K Factor = 13.37 16 40 50.48 2 1 13.639 1.000 120 13.963 to 0.0 13.639 0.0 3640 50.482.2030.0 14.639 0.01940.284 Vel =4.25 0.0 36 50.48 14.247 K Factor = 13.37 40 40 19.90 2 iT 13.639 1.000 120 15.715 to 0.0 13.639 0.433 50 39 19.92.2030.014.639 0.0035 0.051 Vel = 1.67 0.0 50 19.90 16.199 K Factor = 4.94 41 40 19.97 2 iT 13.639 1.000 120 15.716 to 0.0 13.639 0.433 51 39 19.97 2.2030.0 14.639 0.0036 0.052 Vel = 1.68 0.0 51 ____ 19.97 16.201 KFactor= 4.96 42 40 20.21 2 IT 13.639 1.000 120 15.721 to 0.0 13.639 0.433 52 39 20.212.203 0.014.639 0.0036 0.053 Vel = 1.70 0.0 52 20.21 16.207 KFactor= 5.02 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Page 9 Ventana Real II Date 4/20/09 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 44 40 22.34 2 iT 13.639 1.000 120 15.941 to 0.0 13.639 0.433 54 39 22.34 2.203 0.0 14.639 0.0043 0.063 Vel= 1.88 0.0 54 22.34 16.437 KFactor = 5.51 45 40 19.37 2 iT 13.639 1.000 120 15.634 to 0.0 13.639 0.433 55 39 19.37 2.203 0.0 14.639 0.0033 0.048 Vel _=1.63 0.0 55 19.37 16.115 K Factor = 4.83 46 40 46.77 2 iT 13.639 1.000 120 15.401 to 0.0 13.639 0.433 _56 39 46.77 2.203 0.0 14.639 0.0169 0.247 Vel = 3.94 0.0 56 46.77 16.081 K Factor = 11.66 47 40 47.53 2 iT 13.639 1.000 120 15.384 to 0.0 13.639 0.0 57 40 47.53 2.203 0.0 14.639 0.0174 0.255 Vel = 4.00 0.0 57 47.53 15.639 K Factor = 12.02 *FLOAT 30 39 -19.90 3 0.0 14.000 120 15.025 to 0.0 0.0 0.0 31 39 -19.9 3.314 0.0 14.000 -0.0005 -0.007 Vel = 0.74 31 39 -19.97 3 0.0 11.500 120 15.018 to 0.0 0.0 0.0 32 39 -39.873.314 0.0 11.500 -0.0017 -0.019 Vel = 1.48 32 39 -20.20 3 0.0 12.000 120 14.999 to 0.0 0.0 0.0 33 39 -60.07 3.314 0.0 12.000 -0.0037 -0.044 Vel = 2.23 33 39 -22.34 3 0.0 14.500 120 14.955 to 0.0 0.0 0.0 34 39 -82.41 3.314 0.0 14.500 -0.0066 -0.096 Vel = 3.07 34 39 -19.38 3 0.0 14.500 120 14.859 to 0.0 0.0 0.0 35 39 -101.793.314 0.0 14.500-0.0097 -0.141 Vel = 3.79 35 39 51.31 3 0.0 14.000 120 14.718 to 0.0 0.0 -0.433 3640 -50.483.314 0.0 14.000 -0.0027 -0.038 Vel _=1.88 0.0 36 -50.48 14.247 K Factor = -13.37 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Ventana Real II Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf Page 10 Date 4/20/09 Notes *MAIN 50 39 to 51 39 51 39 to 52 39 52 39 to 53 39 53 39 to 55 39 55 39 to 56 39 56 39 to 57 40 57 *FEED 53 39 to 54 39 54 39 to 60 39 60 39 to 70 11 70 11 to 71 11 71 11 to 72 11 72 11 to TR 11 TR 11 to BR 0 19.90 4 0.0 14.000 120 16.199 0.0 0.0 0.0 19.9 4.31 0.0 14.000 0.0001 0.002 Vel = 0.44 19.97 4 0.0 12.000 120 16.201 0.0 0.0 0.0 39.87 4.31 0.0 12.000 0.0005 0.006 Vel = 0.88 20.20 4 iT 27.874 14.100 120 16.207 0.0 27.874 0.0 - 60.07 4.31 0.0 41.974 0.0010 0.042 Vel = 1.32 -173.74 4 iT 27.874 12.500 120 16.249 0.0 27.874 0.0 -113.67 4.31 0.0 40.374 -0.0033 -0.134 Vel = 2.50 19.37 4 0.0 14.500 120 16.115 0.0 0.0 0.0 -94.34.31 0.014.500 -0.0023-0.034 Vel _2.07 46.77 4 0.0 14.000 120 16.081 0.0 0.0 -0.433 --47.534.31 0.0 14.000 -0.0006 -0.009 Vel = 1.05 0.0 -47.53 15.639 K Factor = -12.02 173.74 4 0.0 25.750 120 16.249 0.0 0.0 0.0 173.74 4.31 0.0 25.750 0.0073 0.188 Vel = 3.82 22.34 4 1E 13.937 1.250 120 16.437 0.0 13.937 0.0 196.08 4.31 0.0 15.187 0.0092 0.139 Vel = 4.31 0.0 4 1E 13.937 26.750 120 16.576 0.0 13.937 12.127 196.08 4.31 0.0 40.687 0.0091 0.370 Vel = 4.31 0.0 4 iT 27.874 32.500 120 29.073 1E 13.937 41.811 0.0 196.08 4.31 0.0 74.311 0.0091 0.678 Vel = 4.31 0.0 4 iT 27.874 11.500 120 29.751 0.0 27.874 0.0 196.084.31 0.039.374 0.0091 0.359 Vel = 4.31 0.0 4 1E 13.937 9.500 120 30.110 0.0 13.937 0.0 -196.084.31 0.0 23.437 0.0091 0.213 Vel = 4.31 0.0 4 lB 16.724 11.500 120 30.323 2E 27.874 44.598 4.764 196.08 4.31 0.0 56.098 0.0091 0.512 Vel = 4.31 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 35.599 K Factor= 32.86 140 35.599 2.599 0.0012 0.078 Vel = 2.11 150 38.276 -3.032 0.0013 0.278 VeI= 2.33 150 35.522 6.525 * Fixed loss = 3.06 0.0014 0.166 VeI= 2.33 150 0.0004 42.213 4.331 0.330 VeI= 1.36 150 46.874 0.0 0.0004 0.140 Vel= 1.36 Qa= 250.00 47.014 KFactor= 65.06 Final Calculations - Hazen-Williams - 2007 MILLENNIUM FIRE PROTECTION CRP Page 11 Ventana Real II Date 4/20/09 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 0.0 BR 196.08 *UG BR 0 196.08 6 2E 40.168 25.000 to 0.0 40.168 UG -6 196.08 6.16 0.0 65.168 UG -6 0.0 6 2E 35.786132.000 to iT 38.342 74.128 BFP 1 196.08 5.86 0.0 206.128 BFP 1 0.0 6 2E 35.786 45.000 to IT 38.342 77.962 UG1 -7 196.08 5.86 1G 3.834122.962 -- iZaf 0.0 UG1 -7 0.0 8 1E 22.555883.000 to IC 5.012 27.567 UG2 -17 196.08 7.68 0.0 910.567 U -17 0.0 8 IT 43.857281.000 to IG 5.012105.257 SRC -17 196.08 7.68 3F 33.833386.257 1E 22.555 250.00 SRC 446.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Dec102008 3:10PM HP LASERJET FAX COPY loop Millennium Fire Protection Corp. Date of Test 12110/2008 Time of Test 9:00 AM Elevation: 275' Project: Preformed by: Ventana Real Phase II John Forsysth, Will Hinrich p.2 Test Address: 2175 Salk Ave. Carlsbad, CA 92008 Static 60 PSI Residual 55 PSI Pitot 60 PSI Outlet Dia. 2.5 IN Outlet Coff. 0.62 70.0 Witness by: Elizabeta Karczski Flow at Residual 1177.1 GPM Flow at 20 PSI 3618.1 GPM Flow atO PSI 4503.7 GPM 60.0 50.0 kbR 10.0 0.0 0 500 1000 1500 2000 2500 3000 Flow (GPM) Used for Residual Flow Used for Pressure at specific Flow Q=29.8 x c x d112 x Ov Qf=QF x (hr'0.54 / hf'0.54) hr=((Qf x hf'0.54)IQF)'1 .85 Q= Flow Qf= Flow (at desired pressure) C= Outlet Coff. QF Flow Observed (Flow @ Residual) d= Outlet Dia. hr= Desired t Pressure (Static - Desired Pressure i.e 20 psi, 0 psi) PV--Pitot hf= Observed A Pressure (Static - Residual) 101 Copperwood Way, Ste F • Oceanside, CA 92058 • Phone (760) 722-2722 • Fax (760) 722-2730 License# Cl 6-869040 Dec 102008 3:10PM HP LASERJET FAX p.3 Carlsbad Municipal Water District Potable Water Discharge Event Report Date: Looation Reason for Discharge Event: Type of Event: Dewatoring Water Mains Note: Includes flow testing and iusbIflg Dewater!ng Reservoirs Unscheduled Water Discharge Clear flow path of debris, surface contaminants and/or hazardous materials. Do not remove native vegetation. Erosion control, i.e. sandbags, silt fencing, hay bales, gravel bags, decreasing the velocity of discharge water. Initial Estimated Discharge Flow: - Start Time End Time Pre-Dechiorination Residual: 4stDech1or1natIon Residual O) ,..' (less than 0.1 rngiL.) pH within limits of 6.0 and 9.0 Upon completion of dewatering, ensure that the flow path is free of all temporary erosion prevention materials. Upon completion of dewatering, ensure that any sediment or silted areas are cleared. Water Sampling Performed by:__________________________________________ Comments: Submitted by:____________ Reviewd - (Name&D & ImmF MILLENNium FIRE PROTECTION CORP. Ventana Real II Overhead Fire Sprinkler Material Submittal 4/20/09 DynamFlow@ High Strength Steel Pipe The original high-strength light wall sprinkler pipe with hydraulics superior to Schedule40. Dyna-Flow pipe is the "original" high- strength lightwali sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule- 10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule- 10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Specifications NPS Nominal I.D. Wt. WI. (H20 Filled) Pcs/ WI/Lift (21') WI/Lift (24) Wt/Lift (25)' In; mm In; mm Lbs/Pt; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 11/4 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 11/2 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 21/2' 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4" 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type B, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. (~) <~> 9 Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. tL,Ct3 a vital part of your world '. 16100 S. Lathrop. Harvey, IL 60426 Customer Service: Qr cJiie.. 11350 Norcom Rd. . Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2 -3 DynamThread QD Full Line Sch-40 Replacement Dyna-Thread offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for lire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). The consistent quality of steel used to calculated wall thicknesses at this point make Dyna-Thread facilitates smooth and are both assigned the same CRR of threading and lower maintenance costs. SpecifttI ['] ii- NPS Nominal I.D. WI. Wt. (H20 Filled) Pcs/ Wt/Lift (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg ill 1.080 1.330 1.75 70 1955 2234 2327 25 274 2.0 2.60 70 887 1013 1056 11/4 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11/i 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 1143 2 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 1 16100 S. Lathrop. Harvey, IL 60426 Customer Service: tijco Qr allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 a vital part of your world TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3 -3 I'? I L!JL 96 77 63 54 I 45 1 1/4 125 103 88 74 1 1/2 227 186 159 133 452 362 296 254 213 2½" 671 537 440 377 316 1085 868 711 610 510 1847 1477 1210 1037 869 Notes: a The tables for the maximum load Fpw in the Zone Of Influence are based on specific configuration of mains, branch lines, and Yield Strength. b Assumes branch lines at the center of the main pipe span and near each sway brace. c Assumes branch lines at the third-point of the main pipe span and near each sway brace. d Assumes branch lines at the quarter-point of the main pipe span and near each sway brace. FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Schedule 10 Pine Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. Nominal Pipe Size (in) - Nominal O.D. (in) Nominal ID. (in) Nominal Wall (in) Weight/Ft Bundle Size 1 1.315 1.097 0.109 1.40 lbs/ft 91 1-1/4 1.660 1.442 0.109 1.81 lbs/ft 61 1-1/2 1.900 1.682 0.109 2.08 lbs/ft 61 2 2.375 2.157 0.109 2.64 lbs/ft 37 2-1/2 2.875 2.635 0.120 3.53 lbs/ft 30 3 3.500 3.260 0.120 4.33 lbs/ft 19 4 1 4.500 1 4.260 1 0.120 1 5.62 lbs/ft J 19 Schedule 40 PiDe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I. D. (in) Nominal Wall (in) Weight/Ft Bundle Size 1 1.315 1.049 0.133 1.68 lbs/ft 70 1-1/4 1.660 1.380 0.140 2.27 lbs/ft 51 1-1/2 1.900 1.610 0.145 2.72 lbs/ft . 44 2 2.375 2.067 0.154 3.65 lbs/ft 30 2-1/2 2.875 2.468 0.203 5.79 lbs/ft 30 3 3.500 3.068 0.216 7.58 lbs/ft 19 4 1 4.500 1 4.026 1 0.237 1 10.79 lbs/ft 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q%6 j MULL MflflflMNY ACcompany 1819 Clarkson Road Chesterfield, MO 63017 (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com e-mail: bmtinfo@bulImoosetube.com For additional information, ME contact your salesperson today at (800) 325-4467 or (636) 537-2600 in the USA, or from Canada call (800) 882-4666 <i > APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 2/07 Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittings General Description See Fire Protection PtB] [vds] Submittal Sheet for Pressure Rating and Listing/Approval Information The grooved fittings provide an economical and efficient method of changing direction, adding an outlet, reducing, or capping grooved piping systems. Grooved fittings are available in durable ductile iron or fabricated steel as indicated. Note: Figure 510S and 519S fittings are special short radius fittings with smaller center to end dimensions than standard grooved fittings. Depending on the size and coupling used, there maybe interferences at the bolt pads that require repositioning of the coupling orientation. The use of flange adapters is not recommended with Figures 510S and 519S fittings. Contact Tyco Fire Products for details. WARNING The Fittings described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershould be contacted with any questions. Technical Data Approvals: UL, FM, ULC, VdS, and LPCB; Note: See Fire Protection Submittal Sheet for exact Listing / Approval information. Material: Cast: Figures: 201,210,219,250,260,501,510, 519, 510DE, 501S, 510S and 519S - Ductile iron conforming to ASTM A-536, Grade 65-45-12 Fabricated Steel: Figures 391, 392, 393, 312, 313, 321, 327, 341 and 350 - Carbon Steel, (Sizes 11/4" -6" are Schedule 40); (Sizes 8"- 12" are Schedule 30), conforming to ASTM A-53 Grade B Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, wall thickness, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractoror product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid forand properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwith Tyco Fire Productsorfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/orthe standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit,anyotherobligation in connection with the sale of products or parts of products. Tyco Fire Productsshall notbe responsibleforsprinklersystem design errorsorinaccurate orincomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCO FIRE PRODUCTSWAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE INUEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page 1 of 6 September 2004 TFPI8I0 - C to E Figure 219 Friction Resistance* (Expressed as Equivalent Straight Pipe) Elbow The 90° 45° Branch Run Size Feet Feet Feet Feet Inches MM Meters Meters Meters Meters 11/4 1.9 1.0 4.8 1.9 42.4 0.6 0.3 1.5 0.6 1½ 2.3 1.2 5.8 2.3 48.3 1 0.7 0.4 1.8 0.7 2 3.2 1.6 8.0 3.2 60.3 1.0 0.5 2.5 1 1.0 21/2 3.9 2.0 9.8 3.9 73.0 1.2 0.6 3.0 1.2 4.1 2.1 10.3 4.1 76.1 mm 1.2 1 0.6 3.1 1.2 3 4.9 2.4 12.2 4.9 88.9 1.5 0.7 3.7 1.5 6.5 3.3 16.3 6.5 108.0mm 2.0 1.0 1 5.0 2.0 4 6.5 3.3 TT 6.5 114.3 2.0 1.0 5.0 2.0 8.0 4.0 20.0 8.0 133.0mm 2.4 1.2 6.1 2.4 8.0 4.1 20.0 8.0 139.7mm 2.4 1.3 6.1 1 2.4 5 8.2 4.1 20.5 8.2 141.3 2.5 1.3 6.3 1 2.5 9.5 4.8 23.8 9.5 159.0mm 2.9 1.4 7.2 2.9 9.5 48 23.8 9.5 165.1 mm 2.9 1.4 7.2 2.9 6 9.9 5.0 24.8 9.9 168.3 1 3.0 1.5 1 7.6 3.0 13.1 6.6 32.8 13.1 216.3mm 4.0 2.0 10.0 1 4.0 8 13.1 6.6 32.8 13.1 219.1 4.0 2.0 10.0 4.0 10 16.5 8.3 41.3 16.5 273.0 5.0 2.5 12.6 5.0 12 19.9 49.7 19.9 323.4 6.1 3.0 15.1 6.1 Figure 201 Figure 210 Figure 219 Figure 260f 45° Elbow 90° Elbow Tee En Cap C to E Appx. Wt. C to E Appx. Wt. C to E Appx. Wt. E to E Appx. Wt. Nominal InchesInches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. Size Kg. mm Kg. mm Kg. mm Kg. 1 14 1.75 0.9 2.75 1.0 2.75 1.4 0.88 0.4 44.5 0.4 69.9 0.5 69.9 0.6 22.4 0.2 1 /2 1T7 1.1 7 1.2 2.75 1.8 0.88 0.6 44.5 0.5 69.9 0.5 69.9 0.8 22.4 0.3 5 1.8 2.0 3.25 2.7 0.88 0.9 2" 50.8 0.8 82.6 0.9 82.6 1.2 22.4 0.4 2/2 2.25 2.2 7 3.0 3.75 5.8 0.88 0.9 57.2 1.0 95.3 1.4 95.3 2.6 22.4 0.4 7 2.2 3.0 3.75 5.8 0.94 1.1 76.1 mm 57.2 1.0 95.3 1.4 95.3 2.6 23.9 0.5 2.50 3.5 4.25 4.5 4.25 7.0 0.88 1.1 Y 63.5 1.6 108.0 2.0 108.0 3.2 22.4 0.5 2.88 5.5 4.75 8.5 4.75 11.5 108.0mm 73.0 2.5 120.7 3.9 120.7 5.2 - - ö 5.2 5.00 8.5 5.00 11.8 1.00 2.6 76.2 2.4 127.0 3.9 127.0 5.4 25.4 1.2 133.0mm 3.25 7.7 5.25 11.3 5.25 10.6 82.6 3.5 133.4 5.1 133.4 4.8 - - 3.25 7.7 5.50 11.3 5.50 15.3 0.92 4.7 139.7mm 82.6 3.5 139.7 5.1 139.7 6.9 23.4 2.1 3.25 8.5 5.50 13.5 5.50 17.0 1.00 5.0 82.6 3.9 139.7 6.1 139.7 1 7.7 25.4 2.3 159.0mm 3.50 12.0 6.00 14.6 6.00 13.9 88.9 5.4 152.4 6.6 152.4 6.3 - - 165.1 mm 3.50 12.0 6.50 18.5 6.50 26.0 1.00 7.5 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 6 3.50 12.0 6.50 18.5 6.50 26.0 1.00 7.5 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 216.3mm 4.25 23.0 7.75 36.5 7.75 45.0 108.0 10.4 196.9 16.6 196.9 20.4 - - 8 4.25 23.0 7.75 36.5 7.75 45.0 1.19 12.8 108.0 10.4 1 196.9 16.6 196.9 20.4 30.2 5.8 4.75 31.0 9.00 60.0 9.00 72.1 1.25 20.0 10.. 120.7 14.1 228.6 27.2 228.6 32.7 1 31.8 1 9.1 12 5.25 40.0 10.00 67.0 10.00 92.5 1 36.0 133.4 18.1 254.0 30.4 254.0 42.0 31.8 1 16.3 -Available with tapped plugs, contact Tyco Fire & Building Products. C to E Figure 210 EtoE .- 0 Figure 260 Page 2 of 6 1FF 1810 Figures 201, 210, 219, and 260 For reducing tees and branches, use the value that is corrosponding to the branch size. Example: for 8" x 8" x 2" tee, the branch value 2' is 8.0 feet. * Friction resistance for all elbows and tees except Figures 510S and 519S. Figure 501S Friction Resistance 501S, 510S & 519S (Expressed as Equivalent Straight Pipe) Elbow Tee 90° 45° Branch Run Size Feet Feet Feet Feet Inches MM Meters Meters Meters Meters 2 3.2 1.6 8.0 3.2 60.3 1.0 0.5 2.5 1.0 21/2 3.9 2.0 9.8 3.9 73.0 1 1.2 0.6 3.0 1.2 76•1 mm 4.1 2.1 10.3 4.1 1.2 0.6 3.1 1.2 3 4.9 2.4 12.2 4.9 88.9 1.5 0.7 3.7 1.5 4 6.5 3.3 16.3 6.5 114.3 2.0 1.0 5.0 2.0 139•7 °'°' 8.0 4.1 20.0 8.0 2.4 1.3 6.1 2.4 5 8.2 4.1 20.5 8.2 141.3 2.5 1.3 6.3 2.5 165.1 °° 9.5 4.8 23.8 9.5 2.9 1.4 7.2 2.9 6 9.9 5.0 24.8 9.9 168.3 3.0 1.5 7.6 3.0 8 13.1 1 6.6 32.8 13.1 219.1 4.0 2.0 10.0 4.0 Page 3 of 6 TFP181O Figures 501, 510, 519 and 51 ODE Cto E 4 ,. Figure 501 CtoE k-C to E Figure 510 C to E to E Figure 519 4)- -i. -A---.- C to E- Figure 51 ODE Figure 501 Figure 510 Figure 519 Figure 51 ODE 450 Elbow 90° Elbow Tee 900 Drain Elbow Ifl Nominal C to E Appx. Wt. C to E Appx. Wt. C to E Appx. Wt. C to E A B Appx. Wt. Inches Lbs. Inches Lbs. Inches Lbs. Inches Inches Inches Lbs. Size mm Kg. mm Kg. mm Kg. mm mm mm Kg. 1 /4 1.75 0.9 2.75 1.0 2.75 1.4 44.5 0.4 1 69.9 0.5 1 69.9 11 /2 1.75 1.1 2.75 1.2 2.75 1.8 445 0.5 69.9 0.5 69.9 0.8 - - - 2 2.00 1.8 3.25 2.0 3.25 2.7 50.8 0.8 82.6 0.9 82.6 1.2 - - - 2.2 3.0 5.8 3.75 2.00 2.75 2.7 1 2/2 57.2 1.0 95.3 1.4 95.3 2.6 95.3 50.8 69.9 1.2 2.50 3.5 4.25 4.5 4.25 7.0 4.25 2.34 2.75 3.7 63.5 1.6 108.0 2.0 1 108.0 3.2 108.0 59.4 69.9 1.7 5.2 5.05 8.5 5.00 11.8 5.00 2.85 2.75 7.0 76.2 2.4 127.0 3.9 127.0 5.4 1 127.0 72.4 1 69.9 3.2 8.5 5.50 13.5 5.50 17.0 5.50 3.38 2.75 13.0 82.6 3.9 139.7 6.1 139.7 7.7 139.7 85.9 69.9 1 5.9 T5 12.0 5 18.5 26.0 6.50 3.92 2.75 13.4 6 88.9 5.4 165.1 8.4 165.1 11.8 165.1 99.6 69.9 6.1 8"4.25 23.0 77 36.5 7.75 45.0 7.75 4.95 1 2.75 26.3 10810 10.4 19619 1 16.6 1 19619 20.4 196.9 125.7 69.9 11.9 Figures 501 S, 510S and 519S Figure 510S° Figure 519S° Figure 501S Figure 510S Figure 519S 45° Elbow 90° Elbow Tee C to E Appx Wt. C to E Appx. Wt. C to F Appx. Wt. Nominal Inches Lbs. Inches Lbs. Inches Lbs. Size mm Kg. mm Kg. mm Kg. 2.00 1.8 2.75 1.5 2.75 2.1 2.1 50.8 0.8 1 69.9 0.7 1 69.9 1.0 2.25 2.2 3.00 2.2 3.00 3.0 21/2 57.2 1.0 76.2 1.0 76.2 1.4 2.25 2.2 3.00 2.3 3.00 3.1 76.1 mm 57.2 1.0 76.2 1.0 76.2 1.4 2.50 3.5 3.38 3.0 3.38 4.1 63.5 1.6 85.9 1.3 85.9 1.9 3.00 5.2 4.00 5.6 4.00 7.7 76.2 2.4 1 101.6 2.6 101.6 3.5 3.25 7.7 4.88 8.6 4.88 12.0 139.7 82.6 3.5 1 124.0 3.9 124.0 5.4 3.25 8.5 4.88 8.8 4.88 12.0 50 82.6 3.9 124.0 3.9 124.0 5.4 3.50 12.0 11.00 5.50 15.0 165.1mm 88.9 5.4 139.7 5.0 139.7 6.8 3.50 12.0 5.50 11.2 5.50 15.2 6 88.9 5.4 139.7 5.1 139.7 6.9 4.25 23.0 23.4 6.88 31.2 8' 108.0 10.4 1 17418 1 10.6 174.8 14.2 *Note. Figure 510S and 519S fittings are special soed radius fittings with smaller center to end dimensions than standard grooved fittings. Depending on the size and coupling used, there maybe interferences at the bolt pads which requires repositioning of the coupling orientation. The use of flange adapters is net recommended with Figures 510S and 519S fittings. Contact Tyco Fire Products for details. Page 4 of 6 TFP 1810 Figures 250 and 350 Figure 250 Cast - EtoE- - a-- Figure 350 Fabricated Sizes 3" to 6" h-Eta E- -D- Figure 350 Fabricated Sizes 8" to 12" Figures 250 and 350 Concentric Reducer - Groove x Groove Nominal E to E Appx. Wt. Nominal E to E Appx. Wt. Nominal E to E Appx. Wt. Size Inches Lbs. Size Inches Lbs. Size Inches Lbs. Inches mm Kg. Inches mm Kg. Inches mm Kg. 2.50 1.0 3.50 4.2 4.00 5.8 *2 X 1% 63.5 0.5 *139.7mm X 3 88.9 1.9 *6 x 5 101.6 2.6 2.50 1.3 3.50 4.4 5.00 12.2 *2x1½ 63.5 0.6 *139.7mm X 4 88.9 2.0 8x2 127.0 5.5 2.50 1.2 3.50 4.6 5.00 12.1 *2½x 2 63.5 0.5 5 x 11/2 88.9 2.1 21 8 x /2 127.0 5.5 2.50 1.5 3.50 4.6 5.00 12.0 *76.lmmX 1½ 63.5 0.7 5x2 88.9 2.1 8x3 127.0 5.5 2.50 1.6 3.50 4.5 5.00 11.9 *76.1 mm X 2 63.5 0.8 5 X 2V2 88.9 2.0 8 X 127.0 5.4 2.50 1.3 3.50 4.4 5.00 11.3 3x1¼ 63.5 0.6 5x3 88.9 2.0 8x5 127.0 5.1 2.50 1.3 3.50 4.5 5.00 10.8 3 x 11/2 63.5 0.6 *5 x 4 88.9 2.0 8 x 6 127.0 4.9 2.50 1.3 4.00 5.5 6.00 21.9 *3 X 2 63.5 0.6 *165.1mm X 101.6 2.5 lOx 4 152.4 10.0 3.00 1.5 4.00 6.0 6.00 21.6 *3 x 2½ 76.2 0.7 *165.1mm X 101.6 2.7 lOx 5 152.4 9.8 3.00 2.0 4.00 5.6 6.00 21.1 *3 x 76.1 mm 76.2 0.9 *1651x1397 101.6 2.5 lOx 6 152.4 9.6 3.00 2.2 4.00 6.0 6.00 19.5 4x 11/4 76.2 1.0 * 6 x 2 101.6 2.7 10x8 152.4 8.9 3.00 2.3 4.00 6.0 7.00 28.0 4 x 11/2 76.2 1.0 6 x 2½ 101.6 2.7 12 x 4 177.8 12.7 3.00 2.3 4.00 6.0 7.00 30.0 *4 X 2 76.2 1.0 * 6 X 76.1mm 101.6 2.7 12 X 6 177.8 13.6 3.00 2.3 4.00 6.0 7.00 28.0 *4 x 2½ 76.2 1.0 6 x 101.6 2.7 12 x 8 177.8 12.7 3.00 3.2 4.00 5.9 7.00 33.0 *4 x 76.1 mm 76.2 1.5 * 6 X 101.6 2.7 12 X 10 177.8 15.0 3.00 2.6 4.00 6.3 x 76.2 1.2 *6 X 139.7mm 101.6 2.9 Note: Sizes marked with an asterisk (*) are only available in Figure 250 Cast. Sizes without an asterisk are only available in Figure 350 Fabricated. ADA CAP® Patented Pi e Nominal Dimensions Net O.D. Takeout Center to End Size Outlet Wt. A B C D Inches NPT* Inches Inches Inches Inches Lbs. Inches Kg. mm mm mm mm 1/2 1.25 1.75 1.89 0.77 31.8 44.5 48.0 0.3 34 1.25 1.75 1.89 0.77 11/2 1.900 48.3 31.8 44.5 48.0 0.3 1 1.37 2.00 2.02 0.88 34.8 50.8 51.3 0.4 1/2 1.25 1.75 1.89 0.92 31.8 44.5 48.0 0.4 3/4 1.25 1.75 1.89 0.92 2 2.375 60.3 31.8 44.5 48.0 0.4 1 1.37 2.00 2.02 1.06 34.8 50.8 51.3 0.5 112 1.47 1.97 1.89 1.28 ___ 37.3 50.0 48.0 0.6 3/4 1.47 1.97 1.89 1.28 2'/2 2.875 ___ 73.0 37.3 50.0 48.0 0.6 1.37 2.00 2.02 1.50 1 34.8 50.8 51.3 0.7 ISO-7 threaded outlets are available upon request. Figure 393 Figure 312 Figure 327 Figure 341 Cross 150 lbs. Flange Adapter C to E Appx. Wt. E to E Appx. Wt. Nominal nches Lbs. Inches Lbs. Size mm kg. mm kg. 2.75 2.0 4.00 2.8 11/4 69.6 0.9 101.6 1.3 2.75 2.2 4.00 3.2 11/2 69.9 2.0 101.6 1.5 3.25 2.7 4.0 5.2 2' 82.6 1.2 101.6 2.4 3.75 5.0 4.00 8.0 21/2" 95.3 2.3 101.6 3.6 4.25 7.1 4.00 10.2 108.0 3.2 101.6 4.6 5.00 11.9 6.00 17.2 127.0 5.4 152.4 7.8 5.50 17.1 6.00 21.4 139.7 7.8 152.4 9.7 6.50 27.5 6.00 26.0 6" 165.1 12.5 152.4 11.8 7.75 47.0 6.00 38.4 8' 196.9 21.3 152.4 17.4 9.00 68.0 8.00 65.0 10.1228.6 30.8 203.2 29.5 10.00 107.0 8.00 91.0 12" 254.0 48.5 203.2 41.3 Figure 327 Eta E I I Figure 341 Figure 313 to Page 5 of 6 to E -,.. H Eto TFP 1810 Figures 391, 392, 3935 312 and 313 Figure 391 E to E Figure 392 Figures 391, Figure 312 Figure 313 392 and 393 221/2° Elbow 111/40 Elbow Adapter Nipples E to E Appx. Wt. C to E Appx. WI. C to E Appx. WI. Nominal Inches Lbs. Inches Lbs. Inches Lbs. Size mm Kg. mm Kg. mm Kg. 4.00 0.8 1.75 0.4 1.38 0.4 11/4 101.6 0.4 44.5 0.2 35.1 0.2 4.00 0.9 1.75 0.5 1.38 0.5 1V2' 101.6 0.4 44.5 0.2 35.1 0.2 4.00 1.2 1.88 0.6 1.38 0.6 2' 101.6 0.5 47.8 0.3 35.1 0.3 4.00 1.9 2.00 0.7 1.50 1.1 21/2 101.6 0.9 50.8 0.3 38.1 0.5 4.00 2.5 2.25 1.4 1.50 1.2 101.6 1.1 57.2 0.6 38.1 0.5 6.00 5.5 2.63 2.4 1.75 2.2 152.4 2.5 66.8 1.1 44.5 1.0 6.00 7.4 2.88 4.1 2.00 3.3 152.4 3.4 73.2 1.9 50.8 1.5 6.00 9.5 3.13 5.6 2.00 4.6 6' 152.4 4.3 79.5 2.5 50.8 2.1 6.00 14.2 3.88 11.1 2.00 8.7 8' 152.4 6.4 98.6 5.0 50.8 3.9 8.00 27.0 4.38 14.0 2.13 9.1 10" 203.2 12.2 11.3 6.4 54.1 4.1 8.00 33.0 4.88 22.0 2.25 16.7 12" 203.2 15.0 124.0 10.0 57.2 7.6 Figures 327 and 341 Page 6 of 6 TFP181O Figure 321 Figure 321 Reducing Tee Nominal C to E Appx. Wt. Nominal C to E Appx. Wt. Size Inches Lbs. Size Inches Lbs. Inches mm Kg. Inches mm Kg. 11/2 x 11/2 /4 X 11 3.25 2.0 6x6x4 6.50 26.6 82.6 0.9 165.1 12.1 2x2x11/2 3.25 2.7 6x6x5 6.50 27.0 82.6 1.2 165.1 1 12.2 21/2X21/2X11/4 3.75 4.2 8 x 8 x 2 7.75 36.2 95.3 1.9 196.9 16.4 21/2 x 21/2 x 11/2 3.75 4.2 8x8x3 7.75 36.5 95.3 1.9 196.9 16.6 21/2 x21/2 x2 3.75 4.3 8x8x4 7.75 36.6 95.3 2.0 196.9 16.6 3 x 3 xl ½ 4.25 5.3 8x8x5 7.75 36.8 108.0 2.4 196.9 16.7 3x3x2 4.25 5.5 8 x 8 x 6 7.75 37.0 108.0 2.5 196.9 16.8 3x3x21/2 4.25 5.8 10x10x2 9.00 57.1 108.0 2.6 228.6 25.9 4x4X11/4 5.00 9.8 lOx 10x3 9.00 57.4 127.0 4.4 228.6 26.0 4x4x11/2 5.00 9.9 lOx lOx 4 9.00 57.6 127.0 4.5 228.6 26.1 4x4x2 5.00 10.1 lOx 10x5 9.00 57.8 127.0 4.6 228.6 26.2 4 x 4 x 21/2 5.00 10.3 lOx lOx 6 9.00 58.0 127.0 1 4.7 228.6 26.3 4x4x3 5.00 10.5 lox lox 8 9.00 58.4 1270 4.8 228.6 26.5 5 x 5 x 2 5.50 14.5 12x 12x 3 10.00 80.2 139.7 6.6 254.0 36.4 5 x 5 x 21/2 5.50 14.8 12 x 12 x 4 10.00 80.5 139.7 6.7 254.0 36.5 5 x 5 x 3 5.50 15.2 12 x 12 x 5 10.00 80.7 139.7 1 6.9 254.0 1 36.6 5x5x4 5.50 15.8 12x12x6 10.00 80.9 139.7 7.2 254.0 36.7 6x6x2 6.50 26.5 12x12x8 10.00 91.4 165.1 11.9 254.0 41.5 6x6x21/2 6.50 26.5 12x12x10 10.00 91.8 165.1 12.0 254.0 41.6 6x6x3 6.50 26.5 165.1 12.0 General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions 9001 (I1-1-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. H- CtoE CIa E Figure 321 TAIRILAILU F11116155 101 Threaded Fittings Tyco Fire Products --- www.tyco-grooved.com EENTRAL 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700/ Fax: (215) 362-5385 Grooved Piping Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General Description <S> See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information Ductile Iron threaded fittings (with the exception of California Tees and Street Elbows) conform to ANSI B16.3. They are higher in strength and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties making up the fitting. This is accomplished by adding magnesium while the iron is being poured into it final cast shape. This provides an advantage as the fittings are not as susceptible to leaks or cracking and they are also lighter than standard cast iron. Caution: Installers who have not used ductile iron threaded fittings before should be instructed that the fittings are stronger than the pipe and over- tightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fittings. Apply Teflon tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If you are using an automatic make-on machine, please exercise caution in setting your machine to the proper parameters prior to tightening fittings onto the male pipe threads. Technical Data Figures: 811, 812, 813, 814, 815, 816, 817, 818, 820, 825, 827, 830, 719, California Tees, and Street Elbows Sizes: 1/211 -21/2.. Maximum Working Pressure: 800 Series, California Tees, and Street Elbows: 300 psi Figure 719: 250 psi Approvals: UL, and FM Note: See Fire Protection Submittal Sheet for exact Listing/Approval information. Manufacture Source: Imported Material: Ductile Iron, conforming to ANSI B16.3 (Note: Figure 719 Plugs are constructed of Cast Iron) Thread: N.P.T. r3 Installation Apply Teflon Tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. (See caution in first column) fl Ordering Procedure Ordering information: When placing an order, indicate the full product name. Please specify the quantity, figure number and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, though a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and 11 Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 21-3.0 -2- Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 1 /8 /16 86206 0.24 240 3/4 1/16 3/4 86205 0.40 120 1 1 /2 '/l6 86200 0.64 70 11/4 1/4 1 V1 86201 0.95 40 1'/2 115/16 1/l6 86202 1.24 30 2 21/4 11/2 86203 1.74 20 21/2 211/16 1/16 86204 3.28 10 Figure 815 P F Reducing Tee I - F- -1 D Size Inches A Inches B Inches C Inches D Inches E Inches F Inches Part Number Wt. Lbs. Box Oty. 3/4X3/4X 1/2 1/l6 1/16 11/4 /8 11/16 86235 0.46 95 3/4 X3/4 X1 1/16 1/16 1/8 /8 /8 11/16 86755 0.68 65 1X1/2X1 11/2 1/8 11/2 13/16 13/16 13/16 86236 0.70 55 1 x3/4X 1/2 11/4 1/16 1/8 /16 /8 j 13/16 86756 0.63 80 1 X3/4X 3/4 1/8 1/16 1/16 11/16 3/4 7/ 86757 0.68 65 1x3/4 x1 11/2 1/l6 11/2 13/16 /8 13/16 86237 0.77 55 1x1x 1/2 11/4 11/4 1/8 /16 /16 13/16 86238 0.66 65 lxi x3/4 1/e 1/8 1/16 11/16 11/16 /8 86239 0.73 60 lxi x11/4 111/16 111/16 1/16 1 1 7/8 86240 0.97 45 1x1x11/2 113/16 113/16 1s/8 11/8 i'/8 /8 86241 1.14 35 1V4X1 X1/2 115/16 11/4 1/16 /16 1 86242 0.81 50 1V4x1 x3/4 1 /16 1/8 1/8 3/4 11/16 11/16 86243 0.90 50 11/4X1X1 1/l6 11/2 111/16 13/16 1 86244 1.03 45 1V4x1x11/4 1/4 111/16 1/4 11/16 1 11/16 86245 1.10 40 1'/4x1 X11/2 1/8 113/16 113/16 1/16 11/8 11/16 86246 1.43 30 11/4x11/4 x1/2 1/8 1/8 1/16 11/16 11/16 1 86247 0.87 45 1V4x11/4x/4 1/16 1/l6 1/8 3/4 3/4 11/16 86248 0.96 45 11/4x11/4x1 1/16 1/16 111/16 /8 /8 1 86249 1.10 40 11/4X1V4X1'/2 l/8 1/ 113/16 113/16 113/16 11/16 86250 1.501 30 11/4 x 11/4X2 21/8 21/8 2 1/16 17/16 11/8 86251 2.00 24 11/2 X1X'/2 1/16 1/l6 111/16 11/16 /8 11/8 86252 0.97 40 11/2 X1X3/4 11/2 13/8 1/4 3/4 11/16 1/16 86253 1.14 40 V12 1 X i/8 11/2 113/16 /8 13/16 11/8 86254 1.14 30 11/2X1X11/2 115/16 113/16 115/16 1/16 11/8 1/16 86255 1.52 30 11/2X11/402 1/16 1/16 111/16 11/16 /8 11/8 86257 1.03 40 11/2X11/4X3/4 11/2 1/16 1/4 3/4 3/4 1/16 86258 1.10 40 1V2x11/4x1 1/8 1/16 113/16 I8 /8 11/8 86259 1.31 30 11/2X11/4X2 2/16 21/8 2 1/l6 i/16 11/4 86260 1.94 20 11/2x11/2x1/2 1/16 1/16 111/16 j 11/16 11/16 11/8 86261 1.14 35 11/2x11/2x3/4 11/2 11/2 1/4 3/4 3/4 1/16 86262 1.23 35 11/2x11/2X1 1/8 1/8 113/16 /8 /8 11/8 86263 1.38 30 11/2x11/2x11/4 1'/l6 113/16 1/8 11/16 11/16 l/16 86264 1.50 30 11/2x11/2X2 2/16 2/16 2 1/16 i/16 11/4 86265 2.00 20 2 x 1 x2 21/4 2 1 21/4 1 11/2 1/16 1 11/2 86266 2.181 15 2X11/4X2 21/4 21/8 21/4 11/2 1/16 11/2 86267 2.31115 2x11/2x1/2 11/2 1/16 1/8 3/4 11/16 1/16 86268 1.50 30 2X11/2X3/4 1/8 1V2 115/16 /8 3/4 1/8 86269 1.61 25 2x11/2x1 1/4 1/8 2 1 /8 1/16 86270 1.65 20 2x11/2x11/2 21/16 115/16 2/16 1/16 1/16 1/16 86272 2.03 20 2x1V2x2 21/4 2/16 21/4 11/2 1/16 11/2 86273 2.37 15 2X2X1/2 1V2 11/2 1/8 3/4 3/4 l/16 86222 1.50 30 2x2x3/4 1/8 1/8 115/16 /8 /8 1/8 86223 1.67 20 2x2x1 1/4 1/4 2 1 1 1/16 86224 1.91 20 2X2X11/4 1/ 1/8 21/8 11/8 11/8 1/16 86225 2.05 20 2X2X11/2 2 2 2/l6 11/4 11/4 11/2 86226 2.11 15 2x2x21/2 2/6 2/8 2/8 1/4 1/8 1/l6 86227 3.671 10 21/2x2x3/4 1/4 1/8 1 2/16 /8 /8 1/4 86274 2.22 15 F B-1 D r Figure 812 900 Reducing Elbow A Size Inches A Inches B Inches C Inches D Inches Part Number Weight Lbs. Box Qty. 3/4 x 1/2 1/16 1/16 /8 5/ 86342 0.33 160 1 x 1/2 11/4 1/8 /16 13/16. 86210 0.44 110 1 x 3/4 1/8 1/18 11/16 7 A 86211 0.53 90 11/4 X 1/2 1/l6 11/2 /8 15/16 86212 0.64 75 1V4x 3/4 1/16 1/8 3/4 U/16 86213 0.75 60 11/4 x1 1/16 111/16 /8 1 86214 0.77 55 11/2 x 3/4 11/2 1/4 3/4 1/l6 86221 0.95 45 1V2X 1 1/8 113/16 /8 11/8 86215 0.99 40 11/2 x1V4 113/16 1/8 11/6 1/16 86216 1.14 35 2 x 3/4 15/8 115/16 /8 13/e 86217 1.39 30 2 xl 1/4 21/16 2 1/16 86218 1.58 25 2x 11/2 2 2/16 11/4 1/16 86220 1.67 20 21/2 x 2 2/8 2/e 11/4 1/8 86262 3.01 15 Figure 811 900 Elbow Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 /e /8 86780 0.22 250 3/4 1 /16 86781 0.33 150 1 11/8 13/16 86280 0.48 90 11/4 1/l6 /8 86281 0.73 50 11/2 1/16 11/16 86282 0.93 35 2 111/16 15/16 86283 1.55 18 21/2 115/16 1 86782 2.70 12 Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 11/8 /16 86340 0.33 150 3/4 1/l6 3/4 86341 0.50 90 1 11/2 13/16 86230 0.85 60 1V4 1/4 11/16 86231 1.30 35 11/2 1'/l6 1/16 86232 1.63 24 2 21/4 11/2 86233 2.63 12 21/2 211/16 1/16 86234 4.55 8 Figure 813 45° Elbow Figure 814 Tee Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 3/4 x 1/2 1/4 11/16 86772 0.38 240 1 X 1/2 111/16 1/2 86228 0.38 200 1 x 3/4 1/4 1/2 86229 0.53 110 Figure 825 Extension Piece Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/2 x 11/2 11/2 72751 0.20 300 '/2 x 2 2 72980 0.27 250 3/4 x 11/2 11/2 72981 0.22 250 3/4 x2 1 2 1 72982 1 0.31 200 * Figure 816 Reducing Coupling Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/2 7/8 72776 0.15 500 3/4 1 72777 0.22 300 1 1/i* 72824 0.33 180 11/4 1/16 72756 0.54 110 11/2 1/8 72822 0.68 80 2 11/2 72823 0.96 45 21/2 1/4 72825 1.80 25 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/2 15/16 86292 0.10 500 3/4 11/8 86293 0.18 300 1 11/4 86294 0.28 200 11/4 1/8 86295 0.50 110 11/2 1/16 86296 0.70 80 2 11/2 86297 0.90 45 - --- Figure 820 Cap Figure 719 Cast Iron Plug i Figure 817 Cross Figure 827 Hex Bushing Size Inches A Inches B Inches C Inches D Inches Part Number Weight Lbs. Box Qty. 1 11/2 11/2 13/16 13/16 86284 0.97 45 1V4 1/4 1/4 11/16 11/16 86285 1.59 25 1'/2 1 '5/16 115/16 1/16 1/16 86286 1.89 20 2 2'/4 21/4 11/2 11/2 86287 2.93 10 11/4 X11/4X1 X 1/I6 1/16 1 /8 86289 1.25 30 11/2 X11/2X1 X 113/16 1/8 11/16 115/16 86322 1.48 24 2 x 2 x x 1 2 1/4 11/4 11/16 86291 2.64 10 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1 x 1/2 11/16 72726 0.22 280 1 x3/4 11/1* 72762 0.18 280 11/4 x 1 13/16 72763 0.31 150 11/2 x 1 174 72757 0.53 100 172x11/4 11/4 72764 0.35 100 2 x 1 1/8 72759 0.75 80 2x11/4 1/8 72761 0.69 80 2x 172 1/8 72775 0.62 80 Figure 818 B A Straight Coupling Size Inches A Inches B Inches Part Number Wrench Weight Lbs. Box Qty. 1/2 1/8 5/16 72779 11/8 0.18 360 3/4 1/8 /16 72778 1/8 0.26 200 1 1/4 3/8 72755 111/16 0.44 110 11/4 2 /16 72754 2 0.54 75 11/2 2/16 3/4 72753 2V4 0.71 60 2 2/8 11/8 72752 2/4 1.15 30 21/2 3 3/4 72758 3/8 2.29 18 I1L1_1_J1liJ Figure 830 E_____________ Brass Seat Union 1 [1ff 1 1 Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 1/8 13/16 86207 0.47 110 3/4 2 15/16 86275 0.66 80 1 2/1 13/16 86276 1.08 50 11/4 21/2 11/16 86277 1.54 35 11/2 2/a 1/1* 86278 2.03 25 2 378 1/s 86279 3.15 18 -3- Street Elbows Size Inches A Inches B Inches C Inches Part Number Weight lbs. Box Qty. 1 X /2 11/2 3/4 3 42003 0.70 80 1 X 1 1 V2 3/4 3 42002 0.90 60 m ifi California Tees L Size Inches A Inches B Inches C Inches D Inches Part Number Weight lbs. Box Qty. 1 x'/2x1 1 /2 /8 3 3/4 42000 0.95 50 1 x 1 x 1 1V2 3/4 3 3/4 42001 0.95 45 NILimited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. tLICO/F/ow Control/ Tyco Fire Products Printed U.S.A. 10-01 Fire & Building Products Technical Services: Tel: (800) 381-9312! Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 772 Rigid Coupling - Patented General Description -- gUL o [vds] See Fire Protection FM Submittal Sheet for Pressure Rating and Listing/Approval Information The Figure 772 Rigid Coupling provides rigid joint by firmly gripping along the circumference of the pipe grooves. Rigid couplings are preferred for dry pipe and freezer applications. Figure 772 Rigid Couplings are a proven dependable method of joining pipe and are an economical alternative to welding, threading or using flanges. It is capable of pressures upto 500 psig (3447 kPa) depending on pipe size and wall thickness when used in fire protection services. Rigid Couplings are recommended for thy pipe and freezer applications. WARNING The Figure 772 Rigid Coupling described herein mustbeinstalledandmaintainedincompliance with this document,as we/las withtheapplicablestandards oftheNationalFireProtectionAssociation, inaddition to the standards of any other authorities having Jurisdiction. Failure to do so may impair the pedormance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershouldbecontactedwithany questions. Technical Data Figure: 772 Sizes: 11/4'-12 Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing /Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Mm. Tensile = 110,000 p5i1758,422 kPa) Metric - conforming to ASTM F568M Gasket: (specify when ordering) Grade "A" EPDMA violet color code ambientto +150°F (+66°C) forf ire protection systems. Not recommended for hot water systems. Tr-seal (Grade "E" EPDM), green color code for use in dry pipe or freezer systems. Prelubricated (Grade "A" EPDMA) (See Data Sheet 1FP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, Grade "A" EPDMA, Prelubnicated (Grade "A" EPDMA) orGrade "E" EPDM Tn-Seal, and size. Gninnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyerfor ten (10) years againstdefectsin material and workmanship when paid forand properly installed and maintained under normal useandservice. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured bycompaniesnotaffiliated byownership withTyco Fire Productsorforproductsandcomponents which have beensubjectto misuse, improperinslallaben, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, atlyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDERANYOTHER LEGALThEORY, FOR INCIDENTAL, INDIRECT, SPECIALORCONSEQUENT1ALDAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUTTHE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page 1 of 2 July 2004 TFPI850 Page 2 of 2 TFP1 850 Figure 772 Grooved Coupling Pipe Max.*t Max.t Max.t Nominal Dimensions Net End Gap Pressure End Load Bolt Wt. O.D. A B C Size** Size Inches Inches psi Lbs. Inches Inches Inches Lbs. Dia. L g. mm mm kPa N mm mm mm 11/4" 1.660 0.06 300 649 2.75 4.38 1.81 /8" x 2/4" 1.0 42.4 1.5 1 2,068 2,887 69.9 1 111.3 46.0 1 M10x57 0.5 11/2 0.08 500 1,417 3.00 4.62 1.81 /8' x21/4" 1.0 48.3 2.0 3,447 6,303 76.2 117.3 46.0 MiD x 57 0.5 2" 2.375 0.13 500 2,214 3.41 5.12 1.88 /8" X21/4" 1.5 60.3 3.3 3,447 9,848 86.6 130.0 47.8 M10x57 0.7 21/2" 2.875 0.13 500 3,244 3.91 5.63 1.88 /8" x 2¼" 2.5 73.0 3.3 1 3,447 14,430 99.3 1 143.0 478 1 M10x57 1.1 76.1mm 3.000 0.13 300 2,120 4.19 5.72 2.00 M10x57 2.6 76.1 3.3 2,068 9,430 106.4 145.3 50.8 1.2 3.500 0.13 500 4,808 4.63 6.25 1.88' 3/X21/4' 2.6 88.9 3.3 13,447 21,387 117.6 158.8 47.8 M10x57 1.2 40 4.500 0.19 500 7,948 5.81 7.50 1.97 /8 x 21/4 3.5 114.3 4.8 3,447 35,353 147.6 190.5 50.0 M10x57 1.6 139.7mm 5.500 0.19 300 7,127 7.02 9.72 2.06 M16x83 7.5 139.7 4.8 2,068 31,701 178.3 246.9 52.3 3.4 5.1 5.563 0.19 300 7,288 7.09 9.71 2.04 %" x 31/4" 7.5 141.3 4.8 2,068 32,417 180.1 246.6 51.8 M16x83 3.4 165.1 mm 6.500 0.19 300 9,950 8.09 10.53 2.13 M16x83 7.6 165.1 4.8 2,068 44,258 205.5 267.5 54.1 1 3.4 6" 6.625 0.19 400 13,782 8.09 10.53 2.13 s/s' x3¼" 7.6 168.3 4.8 2,758 61,302 205.5 267.5 54.1 M16x 83 3.4 8" 8.625 0.19 450 26,278 10.56 13.56 2.62 3/4" x 43/4' 18.0 219.1 4.8 3,103 116,885 268.2 344.4 66.5 M20 121 8.2 10" 10.750 0.13 250 22,679 12.84 16.41 2.62 1" x 61/2" 24.6 273.0 3.3 1,724 100,876 326.1 416.8 66.5 M24 x 165 11.2 12" 12.750 0.13 250 31,903 15.41 18.84 2.62 1" x 61/2 42.0 323.9 3.3 1,724 141,905 391.4 478.5 66.5 M24 x 165 19.1 * Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings *0 Gold color coded metric bolt sizes are available upon request. 1 Max End Gap is for cut grooved standard weight pipe. Values for roll grooved pipe will be ½ that of cut grooved. Figure 772 Rigid Couplings have an Anti-Rotation Feature of "gripping teeth" along the coupling keys in sizes 11/4 - 4", which make the Figure 772 perfectly suited for "arm over" installations where the likelihood of rotation is greatest. This feature may eliminate the need of extra hangers to support the arm over due to increased rigidity and gripping force saving time and cost. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (I1-1-1000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. tqC402 liProducts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 705 Flexible Coupling Gefleral Description _ / [vcis] D UL See Fire Protection .0 Submittal Sheet for FM Pressure Rating and Listing/Approval Information The Figure 705 Flexible Coupling is capable of pressures up to 300 psig (2068 kPa) depending on pipe size and wall thickness when used in fire protection services. It provides a dependable method of joining pipe and is suitable for use in a variety of applications. Rigid Couplings are recommended for dry pipe and freezer applications. WARNING The Figure 705 Flexible Coupling described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any otherauthorities ha ving jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinklermanufacturershouldbe contacted with any questions. Technical Data Figure: 705 Sizes: 11/4' - 12 Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing! Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Mm. Tensile = 110,000 psi/758,422 kPa) Metric - conforming to ASTM F568M Gasket: (specify when ordering) Grade "A" EPDMA violet color code ambientto +150°F (+660C) forfire protection systems. Not recommended for hot water systems. Tr-seal (Grade "E" EPDM), green colorcode. Prelubnicated (Grade "A" EPDMA) (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, Grade "A" EPDMA, Prelubricated (Grade "A" EPDMA) orGrade "E" EPDM Tr-Seal, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwith Tyco Fire Products orfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumefor it, any otherobligation in connection with the sale of products or parts of products. Tyco Fire Productsshall notbe responsibleforspdnklersystem design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCO FIRE PRODUCTSWAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN liEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page 1 of 2 July 2004 . TFPI820 Page 2of2 TFP1820 Figure 705 Grooved Coupling Pipe Max. End Gap Max.t Pressure Max.t End load Nominal Dimensions Deflection t Bolt Net Wt. 0. D. A B C Inches! Ter Size** Size Inches Inches psi Lbs. Inches Inches Inches . Foot . Lbs. MM mm kPa N mm mm mm Coupling mm/rn Dia. x Lg. Kg 1/4 1.660 0.13 300 649 2.56 4.19 1.81 40 - 19' 0.90 3/s" x 21/4 1.5 42.4 3.3 2,068 2,887 65.0 106.4 46.0 75.0 1 M10x57 0.7 1.900 0.13 300 850 2.75 4.44 1.81 0.79 3/ X21 /4" 1.6 1 1 /2 48.3 3.3 2,068 3,781 69.9 112.8 46.0 30 - 46' 65.8 M10 x 57 0.7 2.375 0.13 300 1,328 3.25 4.88 1.88 0.63 /8" X21 /4" 1.7 2.1 30 - 1' 60.3 3.3 2,068 5,907 82.6 124.0 47.8 52.5 M10 x 57 0.8 2.875 0.13 300 1,947 3.69 5.50 1.88 0.52 3/' X21/4" 2.0 1 2/2 2° 29' 73.0 3.3 2,068 8,660 93.7 139.7 47.8 - 43.3 M10 x 57 0.9 76.1mm 3.000 0.13 300 2,120 4.00 5.75 1.88 2 -23 0.50 M12x76 3.1 76.1 3.3 2,068 9,430 101.6 146.1 47.8 41.7 1.4 3.500 0.13 300 2,885 4.38 6.50 1.88 20 3' 0.43 1/2' X 3" 3.0 88.9 3.3 2,068 12,832 111.3 165.1 47.8 - 35.8 M12x76 1.4 4.250 0.25 300 4,256 5.50 7.50 2.06 0.70 4.2 108.0mm 30 -22, M12x76 108.0 6.4 2,068 18,931 139.7 190.5 52.3 58.3 1.9 4.500 0.25 300 4,769 5.69 7.75 2.06 0.67 1/2" x 3" 4.0 30 1 114.3 6.4 2,068 21,213 144.5 196.9 52.3 - 55.8 M12x76 1.8 5.250 0.25 300 6,494 6.56 9.50 2.06 0.56 7.2 133.0mm 20 -44 133.0 6.4 2,068 28,885 166.6 241.3 52.3 46.7 M16 x 83 3.3 5.500 0.25 300 7,127 6.81 9.75 2.06 0.56 7.2 139.7mm 139.7 6.4 2,068 31,701 173.0 247.7 52.3 20 -36 46.7 M16 x 83 3.3 5.563 0.25 300 7,288 6.88 9.75 2.06 0.54 -5/8" x 31/4 20 35' 141.3 6.4 2,068 32,417 174.8 247.7 52.3 - 45.0 M16x.83 3.2 6.250 0.25 300 91204 7.56 10.31 2.06 0.48 7.4 159.0mm 159.0 6.4 2,068 40,939 192.0 261.9 52.3 2 - 17, 400 M16 X 83 3.4 6.500 0.25 300 9,950 7.75 10.69 2.06 0.46 7.1 165.1 mm 165.1 6.4 2,068 44,258 196.9 271.5 52.3 2 - 12 38.3 M16 X 83 3.2 6.625 0.25 300 10,336 7.94 10.69 2.06 0.45 5/8" X31/4" 7.1 6 2° 10' 168.3 6.4 2,068 45,975 201.7 271.5 52.3 - 37.5 M16x83 3.2 8.500 0.25 300 17,024 10.07 13.50 2.31 0.35 12.4 216.3 216.3 6.4 2,068 75,723 255.8 342.9 58.7 1 -40, 29.2 M20 x 121 5.6 8.625 0.25 300 17,519 10.19 13.56 2.50 0.35 3/4" X43/4" 14.5 8 1° 40' 219.1 6.4 2,068 77,925 258.8 344.4 63.5 - 29.2 M20 x 121 6.6 10.750 0.25 250 22,679 12.69 16.38 2.63 0.28 1" x 6/" 28.0 10" 273.0 6.4 1,724 100,876 322.3 416.1 66.8 10 - 20' 23.3 M24 x 165 12.7 12.750 0.25 250 31,903 14.94 18.88 2.63 0.23 1" x61/" 36.5 12' 323.9 6.4 1,724 141,905 379.5 479.6 66.8 10 - 7' 19.2 M24 x 165 16.6 * Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. 0* Gold color coded metric bolt sizes are available upon request. 1 Max End Gap and Deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be ½ that of cut grooved. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (I1-1-1000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. 175 lb. WWP Bronze Angle Valves ncification Fire Protection Valve • Screw-in Bonnet • Integral Seat • Renewable Disc Resistant 175 P51/12.1 Bar Non-Shock Cold Water CONFORMS TO MSS SP-80 • UL/ULC LISTED* MATERIAL LIST PART SPECIFICATION Handwheel Nut 300 Series Stainless Steel Identification Plate Aluminum Handwheel Aluminum Commercial Alloy C38000 Stem Silicon Bronze ASTM B 371 Alloy C69430 Packing Gland Bronze ASTM B 62/ ASTM B 16t/ ASTM B 584 Alloy C84400 Packing Nut Bronze ASTM B 62/ ASTM B 584 Alloy C84400/ASTM B 16 Packing Non Asbestos Aramid Fibers w/Graphite Bonnet Bronze ASTM B 62 Alloy C83600 Disc Holder Nut Bronze ASTM B 62 Alloy C83600 Disc Holder Bronze ASTM B 62 Alloy C83600 Seat Disc EPDM Rubber (W) TFE (Y) Seat Disc Nut Bronze ASTM B 62/ ASTM B 96 Alloy C65100 w/SS Washer Body Bronze ASTM B 62/B 584 Alloy C83600 21/2" and 3' size only. t Not on 2' DIMENSIONS-WEIGHTS-QUANTITIES Dimensions Size A B H Weight Box Master In. mm. In. mm. In. mm. In. mm. Lbs. Kg. Oty, Ctn. Qty. 11/4 32 2.19 56 6.13 156 2.19 56 3.71 1.69 1 10 11/2 40 2.38 60 7.19 183 2.38 60 5.54 2.52 1 10 2 50 2.25 57 7.25 184 2.25 57 6.72 3.05 1 10 2h/2 65 3.19 81 10.56 268 3.19 81 16.13 7.33 1 2 3 80 3.88 86 11.13 283 3.88 86 21.72 9.87 1 2 ULIULC Listed for sizes for trim and drain use 11/4", 11/2", " Sizes 21/2" and 3 supplied as 1-311-V with TFE seat disc. T-301-W Threaded T-301 -W NPTx NPT E NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBuRYST. • ELKHART. IN 46516-4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 175 PSI/12.1 Bar Non-Shock Cold Water UL LISTED* MATERIAL LIST PART SPECIFICATION Handwheel Aluminum Handwheel Screw Carbon Steel Stainless Steel (1) Stem Bronze ASTM B 584 Alloy C84400 or ASTM B 505 Alloy C84400 Packing Nut Bronze ASTM B 584 Alloy C83600 or ASTM B 16 Packing Graphite Impregnated (Non Asbestos) Bonnet Bronze ASTM B 584 Alloy C84400 Body Bronze ASTM B 584 Alloy C84400 Seat Disc EPDM Rubber Seat Screw Stainless Steel Pack Washer Sheet Brass KT-65-UL Threaded 175 lb. WWP Bronze Globe Valves Fire Protection Valve • Threaded Ends • Rubber Disc • Screw Over Bonnet ncification <Resntstan> KT-65-UL NPTx NPT DIMENSIONS-WEIGHTS-QUANTITIES Dimensions Size A B Weight Box Master In. mm. In. mm. In. mm. Lbs. Kg. Oty. Cm. Oty, 1/4 8 2.00 50 2.75 70 .48 .22 10 100 3/8 10 2.00 50 2.75 70 .45 .20 10 100 1/2 15 2.28 58 3.12 79 .68 .31 10 60 3/4 20 2.28 58 3,12 79 .74 .34 10 60 1 25 3.12 79 4.50 114 1.68 .76 5 25 "lii Listed for Trim and Drain use - sizes 1/2" 3/4 , 1" Size ¼ and 3/ supplied as KT-65. IS NIBCO INC. WORLD HEADQUARTERS • thiS MIDDLEBLJRY ST. • ELKHART. IN 46516-4740 • USA • PH: 1.830.234.0227 TECH SERVICES PH: 1.888.446,4226 • FAX: 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 111 U Model 76 Gauge Test Valve 300 WOG @ 180 'Max 100% Pressure Tested Screwed Ends UNITED BRASS WORKS, INC. 714 S. Main St., Randleman, NC 27317 800-334-3035 Fax: 800-498-4696 www.ubw.com 1S09011 MATERIAL LIST NO. DESCRIPTION MATERIAL 1 Screw Stainless Steel 2 Hand Wheel Aluminum 3 Packing Nut Brass 4 0-Ring Nitrite 5 Washer Brass 6 Stem Brass 7 Body Bronze Size ¼" A 1.750 B 1.734 C 2.469 Ship Wgt. (lbs.) 0.34 Qty. Per Ctn. 25 OASHCROFT ® Fire Protection, Sprinkler Service Gauge Type 1005P, XUL ASME B 40.1 Grade B (±3-2-3% of span) Underwriters Laboratory listed and Factory Mutual approved Corrosion-resistant ABS case Heat-resistant polycarbonate push-in window Patented PowerFlexTM movement with polyester segment True Zero TM indication, a unique safety feature Type no.: 1005P, XUL Accuracy: ASME B 40.1 Grade B (±3-2-3% of span) Size: 3½" Case: ABS (Polycarbonate blend) Ring: None Window: Polycarbonate, push-in Dial: Black figures on white back- ground Pointer: Black, aluminum Bourdon tube: "C" shaped bronze Movement: Patented PowerFlex with polyester segment Socket: Brass Restrictor: None Ashcroft® fire protection sprinkler gauges are Underwriters Laboratory listed and Factory Mutual approved for fire protection sprinkler service. The case material on Type 1005P, XUL gauges is ABS. The 0-300 psi pressure range is used on "wet" systems where water is available to the sprinkler heads. The 0-80 retard to 250 psi pressure range is used on dry systems where the lines are filled with air pressure until system activation. The patented PowerFlex move- ment with polyester segment is designed to provide unequalled shock and vibration resistance resulting in superior performance and extended gauge life. Operating temperature: —40°F to 150°F Connection: 1/4 NPT lower Ranges: 0-300 psi (water) 0-80 retard to 250 psi (air) UL 393 Listed, UL of Canada Listed and FM approved. Equivalent (single or dual scale) metric scales are available True Zero indication, a standard feature on these gauges, reduces the potential risk of installing a dam- aged gauge on your equipment. Customized dials Other UL listed ranges on application LISTED LOOK TUE THESE AGENCY MARKS ON OUR PRODUCTS Select: 35 W 1005 P H 02L Dial Size: 31/2" Patented PowerF/exTM Movement Case Type Number: 1005 Case Type Material: ABS Socket Material: Brass Connection Size/Location: 1/4 NPT lower 7 III Iictød PRA nnnmitarl 8. Range: 300 psi Consult factory for guidance in product selection Phone (203) 385-0217, Fax (203) 385-0602 or visit our web site at wwwashcroft.com Instruments MODEL 1000 3/4" 1" 11/4" 11/2" 2" The AGF Manufacturing Inc. Model 1000 TESTANDRAIN Provides Both The Test Function And The Express Drain Function For A Wet Fire Sprinkler System. J The Model 1000 Complies With All Requirements Of NFPA-13, NFPA-13R, And NFPA-13D. The Model 1000 TESTANDRAIN Is A Single Handle Ball Valve That Is Light Weight And Compact, Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glasses, And Is 300 PSI Rated. LJ Available In A Full Range Of Sizes From 3/4" To 2" NPT & BSPT, With All Specifiable Orifice Sizes 3/8"'7/1ó', 1/211,17/32", /" (ELO), 3/4" (ESFR) and K.25. The Orifice Size Is Noted On The Indicator Plate And The Valve Is Tapped For A Pressure Gauge. D The Standard Model 1000 TESTANDRAIN Valve Includes A Pressure Gauge Port Tapping And Can Be Ordered With A Relief Valve As A Model 1011 Or 1011 Locking Kit Available Which Provides Superior Vandal Resistance And Prevents Unintentional Alarm Activation. out New Auto0 Visit us COP on the Internet at A?Arr1T MATERIAL LIST PART: MATERIAL: HANDLE STEEL STEM ROD BRASS BALL C.P. BRONZE BODY BRONZE SIGHT GLASS LEXAN® VALVE SEAT IMPREGNATED TEFLON INDICATOR PLATE STEEL HANDLE LOCK SPRING STEEL 1 MODEL 1000 300 PSI & @ > TUTmDRAIN. 3/4" 1 11/4" 1112" 2" PLAN VIEW TO DRAIN C -if 1, 0, FRONT VIEW/HORIZONTAL INSTALLATION ORIFICE SIZE AVAILABLE - 3/8', 17/16", 1/2", 17/32", ELO(5/8'), ESFR(3/4") and K.25 *Available on 11/2 to 2" size units only. DIMENSIONS - INCHES FRONT VIEW/VERTICAL INSTALLATION FROM BRANCH GAUGE INLET / PROVIDED © - STREET EL DRAIN 0 TO DRAIN I - STREET EL OR PIPE I TO DRAIN RIGHT HAND/STRAIGHT INSTALLATION APPROVALS: D UL and ULC Listed D FM Approved except 3/4" U NYC-BSA NO. 720-87-SM U CA. State Fire Marshall SIZE A B C D E F G H 3/4" 5 1/1611 1 1/2" 2 3/16" 3 5/8" 3 3/8" 1 1311611 4 910 63l8' 128mm 37.58mm 55.65mm 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm 1" 5 1Vie' 1 1/211 2 3/16" 3 I8" 3 /8" 1 13/1611 4 u/i? 6 /8" 128mm 37.58mm 55.65mm 93.23mm 85.88mm 45.30mm 117.12mm 162.42mm 5 /io" 1 11/1611 2 9/0 4 1/41' 3 /io" 1 15/0 5 /io 5 1/211 4 137.70mm 42.70mm 65.36mm 108.36mm 82.84mm 50.89mm 141.39mm 192.28mm 1 1/2n 6 /16" 1 'io" 3 1/4" 5 1/u" 3 /8" 2 '8" 8 1/411 10 i8" I 163.38mm 45.50mm 81.50mm 127mm 99.18mm 66.97mm 206.63mm 273.60mm 2" ___ 67/16" 1 13/1611 3 1/4" 5 1/1611 1 3 /8" I 25/8" 8 1/411 107/811 163.38mm 46.50mm 81.50mm 127mm 99.18mm 66.97mm 206.63mm 273.60mm **3/4rr Valve UL listed only. UL LISTING EX4019 AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 T: (610) 240-4900 / F: (610) 240-4906 Email: info@testandrain.com Web: www.testandrain.com RiserPACK and TESTanDRAIN are registered trademarks of AGF MADE IN U.S.A. JOB NAME: ARCHITECT: ENGINEER: CONTRACTOR: 3/02 tqCU /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-FRB - 28,4.2,5.6, and 8.0 K-factor Upright, Pendent, Quick Response, and Recessed Pendent Sprinklers Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20 (1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. - Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K, 1/2"NPT 1Y1231 - Pendent 2.8K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.61K, 1/2"NPT TY3231 - Pendent 5.61K, 1/2"NPT 1Y4131 - Upright 8.0K, 314"NPT 1Y4231 - Pendent 8.0K, 3/4'NPT Page 1 of 10 APRIL, 2006 TFPI7I ESCUTCHEON PLATE SEATING SURFACE 2-1/4" (57,2 mm) 1-9/16 (39,7 mm) 7/16(11,1 mm) 1/2 ** NOMINAL NPT MAKE-IN TFPI7I ESCUTCHEON 7/16(11,1 mm) STYLE 100r20 PLATE SEATING 1/2" ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON NPT T__ 2-3/16" (55,6 mm) YFLATS (38,1mm) 1-1/2" C SSP DEFLECTOR* 2-7/8" (730 mm) DlA. SSU * DEFLECTOR 7/16" (11,1 mm) \JOMINAL MAKE-IN 2-3/16" (55,6 mm) 6* 1/2" NPT** Page 2 of 10 STYLE 10 or 20 RECESSED su ESCUTCHEON DEFLECTOR (11,1 mm) FFLATS NOMINAL 7/16 MAKE-IN 2-3/16' H (55,6 mm) 1 1/2" NPT** SSP DEFLECTOR * H— 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYI 131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT SSP DEFLECTOR * PENDENT 2-7/8 (73,0 mm) DIA. RECESSED PENDENT TFPI7I ESCUTCHEON 7/16(11,1 mm) STYLE 10 or 20 PLATE SEATING , ** NOMINAL RECESSED SURFACE MAKE-IN ESCUTCHEON 2-3/16 (55,6 mm) 1-1/2" (38,1 mm) Page 3 of 10 SSU * DEFLECTOR NOMINAL 4 LI]J;kc1'.i S1I1SUE•]I 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame Screw **Pipe thread connecticns per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2(12,7mm) STYLE 30 or 40 PLATE SEATING 3/4fl** NOMINAL RECESSED SSU* SURFACE MAKE-IN ESCUTCHEON NPT DEFLECTOR 10 A _____ 1/2" 6* 2-5/16" ______ ___________ U NOMINAL I (12,7 mm) I MAKE-IN (58,7 mm) 1-9/ __________ 2-1 (39,7 mm) W L WRENCH (57,2 1 14" 2 mm) FLATS SSP DEFLECTOR* 2-7/8" (73,0 mm) DIA. 3/4 NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame Screw **Pipe thread connection:; per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4 131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/barl/2) K = 4.2 GPM/psi112 (60,5 LPM/bar112) K = 5.6 GPM/psi112 (80,6 LPM/ba1112) K = 8.0 GPM/psi112 (115,2 LPM/bar112) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ............Bronze Button ........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ..............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. 4— Page 4 of 10 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME J PLATED I WHITE*** POLYESTER 2.8 1/2 PENDENT (TY1231) and UPRIGHT (TYII3I) 135°F/57C Orange 1,2,3,5 155°F/68°C Red 175°F/79C Yellow 2O0F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY1231)* Figure 5 135°F/57°C Orange 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 200F/93°C Green RECESSED PENDENT (TY1231)** Figure 6 135°F/57°C Orange 155F/68°C Red 175°F/79°C Yellow 20UF/93°C Green 4.2 1/2' NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/57C Orange 1,2 155°F/68C Red 175F/79°C Yellow 200°F/93°C Green 286F/141 °C Blue RECESSED PENDENT (TY2231)* Figure 7 135F/57°C Orange 155°F/68C Red 175°F/79°C Yellow 200°FI93C Green RECESSED PENDENT (TY2231)** Figure 8 135°F/57C Orange 155°F/68C Red 175°F/79°C Yellow 200F/93°C I Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-F. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40(3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS TFPI7I Page S. of 10 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL I CHROME WHITE*** LEAD LIQUID BRASS PLATED OLYESTER I COATED 135"F/57°C Orange PENDENT (TY3231) and 1,2,3,4,5,6,7 1,2,3,5 155"F/68°C Red 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 5.6 (TY3131) 286°F/141°C Blue 1/2" NPT 135°F/57°C Orange RECESSED PENDENT (TY3231)* 1,2,4,5 N/A 155°F/68°C Red 175"F/79°C Yellow Figure 9 200°F/93"C Green 135"F/57"C Orange I RECESSED PENDENT (TY3231)** 1, 2, 3, 4, 5 I I I 1, 2, 4, 5 I N/A 155"F/68°C Red 175°F/79°C Yellow Figure 10 Green 200°F/93°C 135°F/57°C Orange PENDENT (TY4231) and UPRIGHT 1, 2, 3,4,5,6,7 1,2,5 155"F/68°C Red 175°F/79"C Yellow 200°F/93"C Green 8.0 (TY4131) 286°F/141"C Blue 3/4" NPT 135°F/57°C Green RECESSED PENDENT (TY4231)* 1, 2, 4, 5 N/A 155°F/68"C Orange 175°F/79°C Red Figure 11 200°F/93"C Yellow 135°F/57"C Orange RECESSED PENDENT (TY4231)** 1,2,3,4,5 N/A 155"F/68"C Red 175"F/79"C Yellow Figure 12 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprirkiers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutchecn, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutchecn, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 10 TFPI7I SPRINKLER FINISH K TYPE NATURAL I CHROME WHITE LEAD BRASS PLATED OLYESTER I COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT(TY4131) 175 PSI (12,1 BAR) N/A 3/4,, RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY323) (SEE NOTE 1) N/A PENDENT (1Y4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4, RECESSED PENDENT NPT (TY4231) N/A NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI7I 2-7/8 DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING rr 1/8" (3,2mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4(6,4 mm) (57,2 mm) 71 MOUNTING rLJ,I I (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) 3/4" (19,1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Page 7 of 10' - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) [ (12,7±3,2 mm) 2-1/4" DIA. 1/4(6,4 mm)l SPRINKLER PLATE FI TT ING FACE OF 57,2 mm) MOUNTING I (3,2 mm) F 1/8" \ MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2(12,7mm) r (12,7±3,2 mm) 2-1/4" DIA. I 1/4" (6,4 mm) FACE OF (572mm) MOUNTING SPRINKLER PLATE FITTING _ _ $ (3,2 mm)I \ MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) I TYFRB 1" (25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 5/8±1/4 (159±6,4 mm) FACE OF SPRINKLER FITTING 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random Page 13 of 10 - 2-7/8 DIA. - 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA 1/4" (6,4 mm) FACE OF FITTING SPRINKLER 57,2 mm) MOUNTING PLATE ________ (3,2 mm) MOUNTING SURFACE SERIES / l-l/4"(31,Bmm) CLOSURE TYFRB 3/4" (19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING r LJ lc mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TV-FRB 13/16" (20,6 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT TFPI7I 2-7/8" DIA. (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. i 1/4(6,4mm) (57,2 mm) MOUNTING - OIATC 1/8" I (32mm) I MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) 1" (25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) _ 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER I _ I FITTING 1/8" (3.2 mm) PLATE I \ - MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TV- F RB 1-1/16" (27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4' NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 9 of 10' P/N 57-XXX-X-XXX I MODEL/SIN I I _[ 1 7 3 9 7 TY4131 SPRINKLER NATURAL BRASS WHITE POLYESTER WHITE (RAL9010)* CHROME PLATED 1 LEAD COATED _ I RATING 135 135°F/57°C 155 155°F/68°C 175 175°F/79°C 200 200°F193°C 286 286F/141C * Eastern Hemisphere sales only. 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4'NPT) 391 8.0K PENDENT (3/4'NPT) TY4231 TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foreaoino warranty is made in Iiti of any andaiLother warranties. ex- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Speciy: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. ttiCe /Fire & Building / )Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series RFII - 56 K-factor "Royal Flush II" Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Description The Tyco® Series RFII Quick Response (3 mm bulb) & Standard Response (5 mm bulb), 5.6 K-Factor, "Royal Flush II" Concealed Pendent Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. It is the best choice for archi- tecturally sensitive areas such as ho- tel lobbies, office buildings, churches, and restaurants. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of suspend- ed ceiling panels for access to building service equipment without having to first shut down the fire protection sys- tem and remove sprinklers. Also, the separable two-piece design of the Sprinkler provides for 1/2 inch (12,7 mm) of vertical adjustment, to provide a measure of flexibility with re- gard to which the length of fixed pipe drops to the sprinklers must be cut. The Series RFll Sprinklers are shipped with a Disposable Protective Cap. The IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Protective Cap is temporarily removed for installation, and then it can be re- placed to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board, ceiling tiles, etc. by gently pushing the ceiling product against the Protec- tive Cap. When the ceiling installation is complete the Protective Cap is re- moved and the Cover Plate Assembly installed. As an option, the Series RFII Standard Response (5 mm bulb) "Royal Flush II" Concealed Pendent Sprinklers may be fitted with a silicone Air and Dust Seal (Ref. Fig. 5). The Air and Dust Seal is intended for sensitive areas where it is desirable to stop air and dust travel through the cover plate from the area above the ceiling. r.iir. The Series RFll Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number TY3551 (5 mm bulb) TY3531 (3 mm bulb) Technical Data Approvals: UL and C-UL Listed. FM Approved NYC under MEA 353-01-E. LPCB (Ref. No. 094a/09 for TY3551 & 094a/10 for TY3531) The approvals apply only to the ser- vice conditions indicated in the De- sign Criteria section. Approvals for Air & Dust Seal: (Part # 10908100) UL and C-UL Listed for use with the RFll (TY3551); Standard Response Concealed Sprinkler. Maximum Working Pressure: Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC. Maximum 175 psi (12,1 bar) by FM and LPCB. Temperature Rating: 155°F/680C - Sprinkler 139°F/59°C - Plate 200°F/930C - Sprinkler 165°F/740C - Plate Discharge Coefficient: K= 5.6 GPM/psi112 (80,6 LPM/bar112) Adjustment: 1/2 inch (12,7 mm) Finishes: Refer to Ordering Procedure section. Page 1 of 4 MAY, 2008 TFPISI Page 2 of 4 TFPI8I, 1/2 NPT SEALING ASSEMBLY FRAME CAP - SUPPORT t CUP WITH BULB ROLL FORM - THREADS - COMPRESSION CREW S GUIDE PINS (2) DEFLECTOR (DROPPED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO RETAINER SUPPORT CUP 11 WITH THREAD UNTIL MOUNTING 0 0 _- DIMPLES SURFACE IS FLUSH WITH EJECTION CEILING SPRING SOLDER 1C 't± COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY Physical Characteristics: Frame ...................Bronze Support Cup.. . Chrome Plated Steel Guide Pins .........Stainless Steel Deflector.................Bronze Compression Screw.........Brass Blub ......................Glass Cap.............Bronze or Copper Sealing Assembly................ Beryllium Nickel w/ Teflont Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel tDuPont Registered Trademark Patents: U.S.A. Patent No. 4,014,388 Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler Assembly. At this point the Deflector supported by the Guide Pins drops down to its operational position. The glass Bulb Contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Design Criteria The RFII (TY3551), 5 mm Bulb Type, Concealed Pendent Sprinklers are UL and C-UL Listed as standard response -standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Approved as standard response -standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The RFII (TY3531) 3 mm Bulb Type, Concealed Pendent Sprinklers are UL and C-UL Listed as quick response standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Approved as standard response -standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The Series RFll Concealed Pendent Sprinklers are only listed and approved with the Series RFll Concealed Cover Plates having a factory applied finish The Series RFII must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Installation The Tyco® Series RFII must be in- stalled in accordance with the follow- ing instructions: 'i.iti.i Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 1550F/680C and 3/32 inch (2,4 mm) for the 200°F/930C temperature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to max- imum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under-or over-tightening the Sprinkler/Support Cup Assembly. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be in- stalled in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4. Wrench tighten the sprinkler using only the RFII Sprinkler Wrench (Ref. Figure 3). The RFII Sprinkler Wrench is to be applied to the Sprin- kler as shown in Figure 3. Step 5. Replace the Protective Cap (Ref. Figure 4) by pushing it upwards until it bottoms out against the Sup- port Cup. The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Pro- tective Cap. WLIItM As long as the Protective Cap remains in place, the system is considered to be "Out of Service". -\ -- -- - V MANUFACTURER DEFLECTOR COVER PLATE PRESET GAP IN DROPPED RETAINER 3/32 (2,4 mm) POSITION ASSEMBLY COVER PLATE DIAMETER DIMENSION A 3/16'to11/16' (4,8 to 17,5 mm) REFERENCE COVER PLATE PROFILE DEPTH DIMENSION B 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPIBI Page 3 of 4 \ FACE OF SPRINKLER FITTING FITTING SPRINKLER SUPPORT CUP ASSEMBLY 1/2 (12,7 mm) THREADED - D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE CLEARANCE HOLE - DIAMETER DIMENSION Step 6. After the ceiling has been completed with the 2-1/2 inch (63,5 mm) diameter clearance hole and in preparation for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/Re- tainer Assembly until the Retainer Fig- ure 2 (or Air and Dust Seal -Figure 5) contacts with the ceiling. Do not con- tinue to screw on the Cover Plate/Re- tainer Assembly such that it lifts a ceil- ing panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Retainer As- sembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fit- ting must be repositioned. Care and Maintenance The Tyco® Series RFII must be maintained and serviced in accordance with the following instructions: mm Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. When properly installed, there is a nom- inal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, Page 4 of 4 TFPI8I, SUPPORT SP SUPPORT RINKLER FACE OF ORIENT CEILING SEAL BEVEL AS COVER SHOWN PLATE RETAINER ASSEMBLY CLEAN ROOM LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceiling is to be repaint- ed after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factor,' painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection sys- tem main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age to the sprinklers -before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace it immediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authori- ties having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability. Sprinkler Assembly Specify: (SIN), (specify temperature rating) Series RFII Concealed Pendent Sprinkler, P/N (specify). 155°F/68°C 200°F193°C TY3551 51-790-1-155 51-790-1-200 TY3531 51-792-1-155 51-792-1-200 Separately Ordered Cover Plate: Specify: (specify temperature rating) Series RFII Concealed Cover Plate with (specify finish), P/N (specify). 139°F/59°C(a) 165°F/74°C(b) Brass..........56-792-1-135 56-792-1-165 Chrome........56-792-9-135 56-792-9-165 Signal White (c) (RAL 9003) 56-792-4-135 56-792-4-165 Grey White (d) (RAL 9002) 56-792-0-135 56-792-0-165 Pure White (e) (RAL 9010) 56-792-3-135 56-792-3-165 Custom ........56-792-X-135 56-792-X-165 For use with 155°F/68'C sprinklers. For use with 200°F/93°C sprinklers. Previously known as Bright White. Previously known as Standard White. Eastern Hemisphere sales only. Sprinkler Wrench: Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal: Specify: Air and Dust Seal, P/N 56-908-1-001. ©2008TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCU /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-B - 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description The Series TY-B, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers described in this data sheet are stand- ard response - standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupan- cies such as banks, hotels, shopping malls, etc. They are designed for in- stallation along a wall or the side of a beam and just beneath a smooth ceil- ing. Sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desir- able. The recessed version of the Series TY-B Horizontal Sidewall Sprinkler is intended for use in areas with a fin- ished wall. It uses a two-piece Style 10 Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush sidewall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe nipples to the sprinklers must be cut. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers 1Y3351 - Horizontal TY3451 - Vertical Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status) Maximum Working Pressure Refer to Table B. Discharge Coefficient K = 5.6 GPM/psi112 (80,6 LPM/bar112) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated. Page 1 of 6 APRIL, 2006 TFPI6I .4- Page 2 of 6 TfP161' SPRINKLER FINISH (See Note 10) K TYPE TEMP. BULB NATURAL I CHROME WHITE*** LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135°F/57°C Orange HORIZ. SIDEWALL (1Y3351) 1,2,3,4,9 1,2,3,9 1,2,3,9 1,2,3,9 1,2,3,9 155°F/68°C Red 175°F/79°C Yellow 200°F/93C Green 5.6 1/2" 286°F/141C Blue 2**, 3** g** ** 3** 9** 360°F/182°C Mauve 1,2,4,9 1,2,9 N/A NPT RECESSED 135°F/57°C Orange HORIZ. SIDEWALL (FY3351)* 1,2,3,9 N/A 155°F/68°C Red 175°F/79°C Yellow Figure 3 200°F/93°C Green 135F/57°C Orange 5.6 1/2" VERTICAL SIDEWALL (TY3451) 4,5,6,7,8,9 5,6,7,9 5,6,7,9 5,6,7,9 155°F/68°C Red 175°F/79°C Yellow NPT Installed 200°F/93°C Green Pendent 286F/141°C Blue 5** 6**, 7** 9** 5** 6**, 7** 9** or Upright 360F/1 82C Mauve 4, 5, 6, 8, 9 N/A NOTES: Listed by Underwriters Laboratories, Inc. (UL) for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. Approved by Factory Mutual Research Corporation (FM) for use in Light Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05 & 007k/03) at a 4 to 6 inch (100 to 150 mm) deflector to ceiling distance. Listed by Underwriters Laboratories, Inc. (UL) for use in Light and Ordinary Hazard Occupancies. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL:) for use in Light and Ordinary Hazard Occupancies. Approved by Factory Mutual Research Corporation (FM) for use in Light Hazard Occupancies. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05 & 007k/03). Approved by the City of New York under MEA 354-01-E. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) 3/4" Total Adjustment Recessed Escutcheon. ** 150°F/66°C Maximum Ceiling Temperature. Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze HSW Deflector ........Bronze VSW Deflector ........Copper Patents U.S.A. 5,810,263 Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-B Horizontal and Verti- cal Sidewall Sprinklers are intended for fire protection systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets). Only the Style 10 Recessed Escutcheon is to be used for recessed horizontal installations. !TFPIBI Page 3 of 6 SPRINKLER FINISH K TYPE NATURAL CHROME I WHITE LEAD WAX WAX OVER BRASS PLATED I POLYESTER COATED COATED LEAD COATED HORIZONTAL SIDEWALL 250 PSI (17,2 BAR) (TY3351) OR 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) RECESSED HORIZ. 5.6 1/2" SIDEWALL (TY3351) (SEE NOTE 1) N/A NPT VERTICAL SIDEWALL (TY3451) 175 PSI (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Installation The Series TY-B Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135"F/57°C to 3/32 inch (2,4 mm) for the 360°F/182°C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-B Horizontal and Ver- tical Sidewall Sprinklers must be in- stalled in accordance with the follow- ing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright po- sition with the arrow on the Deflector pointing away from the wall. * Temperature rating is DEFLECTOR indicated on deflector HAT Di: or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. 6* 4 2 3 1 9/16" WRENCH 1/2" ** (14,3 mm) FLATS NPT __ 1-13/16" 7/16" (46,0 mm) (11,1 mm) CENTERLINE NOMINAL OF SPRINKLER MAKE-IN 1 - Frame WATERWAY 1-1/2" 2 - Button 3 - Sealing (38,1 mm) Assembly 4- Bulb 2-3/16" - 5 - Compression Screw (55,6 mm) 6- Deflector I ESCUTCHEON STYLE 10 - I PLATE SEATING RECESSED SURFACE ESCUTCHEON 2-7/8" DIA. (73,0 mm) FIGURE 1 5.6 K-FACTOR STANDARD RESPONSE SERIES TV-B HORIZONTAL SIDEWALL (TY3351) SPRINKLERS ARROW MUST 7/16" FROM AND BE (11,1 mm) POINT AWAY _( PERPENDICULAR ** NOMINAL 1/2" TO THE BACK MAKE-IN WALL SURFACE NPT I !I11u1,1 SHOWN SHOWN CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5 - Compression 7- Ejection Spring Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 5.6 K-FACTOR STANDARD RESPONSE SERIES TV-B VERTICAL SIDEWALL (TY3451) SPRINKLERS Page 4 of 6 TFPI6I' Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 4), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figure 1 or 2, the W-Type 6 Sprinkler Wrench or the Crescent wrench, as applicable, is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. The Series TV-B Recessed Horizon- tal Sidewall Sprinklers must be in- stalled in accordance with the follow- ing instructions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word 'TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 10 Mounting Plate over the sprinkler ESCUTCHEON PLATE SEATING SURFACE 2-3/16" 6 mm) (55,6 mm) 1- (38, threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 5). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 Closure over the Series TY-B Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFPI6I 5/8±1/4" (15,9±6,4 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING CLOSURE - _________ 2-7/8" DIA. (73,0 mm) SERIES TY-B 2-1/4"DIA. (57,2 mm) MOUNTING PLATE /1 1/8" (3,2 mm) 1-1/4' (31,8 mm) 3/4" (19,1 mm) 3/4(19,1 mm) 1/4(6,4mm) FIGURE 3 SERIES TY-B RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON Care and Maintenance The Series TY-B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the Page 5 of 6 WR ENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) FIGURE 4 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 5 W-TYPE 7 RECESSED SPRINKLER WRENCH corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Page 6 of 6 T.FPI6I P/N 57-XXX-X-XXX SPRINKLER L RATING I TEMPERATUF 135 135°F/57°C 155 155°F/68°C 175 175°F/79°C 200 200°F/93°C 286 286°F/141°C 360 360F/1 82°C 286°F/141C MAX. 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED 6 WAX COATED 8 WAX OVER LEAD 286°F/141°C MAX. * Eastern Hemisphere sales only. MODEL/SIN 578 I HORIZONTAL SIDEWALL I 1Y3351 575 I VERTICAL SIDEWALL I TY3451 TABLE C PART NUMBER SELECTION SERIES TV-B HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. press or implied, including warranties of merchantability and fitness fora oar- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Stand- ard Response, (specify K-factor), (specify temperature rating), Series TY-B (specify Horizontal Sidewall or Vertical Sidewall) Sprinkler with (spec- ify type of finish or coating), P/N (spec- ify from Table C). Recessed Escutcheon: Specify: Style 10 Recessed Escutch- eon with (specify*) finish, P/N (spec- ify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCD /Fire & Building I Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Model WSTM - 56 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description The Model WS, 5.6 K-factor, Horizon- tal Sidewall and Pendent Vertical Sidewall, Specific Application Window Sprinklers are fast response, glass bulb type spray sprinklers. These sprinklers are the first sprin- klers ever to be specifically Listed to provide protection for heat strength- ened or tempered glass windows us- ing closed sprinklers. As part of the testing, the gas flow required to achieve the time/temperature relation- ship specified in ASTM E119 was es- tablished in a test furnace without sprinkler protection. A window assem- bly protected with Model WS Specific Application Window Sprinklers was then installed in the test furnace and the same gas flow conditions were maintained for a two hour test period. No cracking or visible damage to the window was permitted during the test period (even when a hose stream was directed at the window). The success of the Model WS Specific Application Window Sprinkler is based on its specially designed deflector that ensures that the spray pattern wets the entire surface of the window, and its fast response thermal sensitivity. Based on this successful testing, the Model WS Specific Application Win- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. dow Sprinkler can be used as interior protection of windows or glazing in a sprinklered building or non-sprinklered building. Also, the Model WS Specific Application Window Sprinkler can be used as a open sprinkler for "Outside Sprinkler Protection against Exposure Fire", using the design requirements of NFPA. As with any specific application sprin- kler, the installation instructions in- cluded in this data sheet must be pre- cisely followed. ICC Evaluation Service, Underwriters Laboratories of Canada (ULC), or Building Materials Evaluation Commission (BMEC) guidelines apply, consult the specific approval report. WARNING The Model WS Specific Application Window Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions. Sprinkler Identification Number TY3388 - Horizontal Sidewall TY3488 - Pendent Vertical Sidewall TY3388 is a redesignation for C3388. TY3488 is a redesignation for C3488. Page 1 of 8 JULY, 2005 TFP620 Page 2 of 8 Tf P6 20 Discharge Coefficient K = 5.6 GPM/psi1l2 (80,6 LPM/barll2) Temperature Rating 1550F/68°C & 200°F/93°C The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. * Temperature rating is indicated on Deflector. 6* CROSS SECTION PLAN THREAD SPRINKLER INDICATED TOP RELIEF FRAME ARMS OF SPRINKLER ECTOR 1/2 NPT 13/16 (20,6 mm) 1-5/8 DIA. (41,3 mm) 7/16 (11,1 mm) J WRENCH NOMINAL MAKE-IN FLATS ORIENT DEFLECTOR 2-1/8 TOWARDS (54,0 mm) WINDOW SIDE ELEVATION FIGURE 1 MODEL WS, HORIZONTAL SIDEWALL SPECIFIC APPLICATION WINDOW SPRINKLER Components: 1 - Frame 4 - Bulb * Temperature Button 5 - Compression rating is indicated Sealing Screw on Deflector. 1/2 7/16' (11,1 mm) Assembly 6 - Deflector * NPT NOMINAL MAKE-IN WRENCH FLATS ORIENT ______ SPRINKLER : FLOW ARROW ______ (INDICATED ON FRAME 2J/8 DEFLECTOR) TOWARDS WINDOW ARMS (54, mm) CENTERLINE OF SPRINKLER 6* SPRINKLER 1-1/32" WATERWAY DEFLECTOR (26,2 mm) j 5/8' 2-1/16" (15,9 mm) (52,4 mm) CROSS SECTION TOWARDS WINDOW ELEVATION FIGURE 2 MODEL WS, VERTICAL PENDENT SIDEWALL SPECIFIC APPLICATION WINDOW SPRINKLER Technical Data Approvals UL, C-UL, and ULC Listed. NYC under MEA 289-04-E. (The approvals only apply to the serv- ice conditions indicated in the Design Criteria section.) Additional Recognition ICC Evaluation Service (ICC-ES Legacy Report NER-516) Building Materials Evaluation Com- mission (BMEC 01-11-263) Pipe Thread Connection 1/2 inch NPT Components: 1 - Frame 2 - Button Sealing Assembly Bulb Compression Screw Deflector * Finish Polyester Coated, Chrome Plated, or Natural Brass Physical Characteristics Frame ..............Brass Button .........Bronze/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ........Glass (3 mm dia.) Compression Screw ......Brass Deflector .......Brass/Bronze f DuPont Registered Trademark CENTERLIF' OF SPRINKL WATER WA TFP62O Page 3 of 8 Design Criteria The Model WS Window Sprinklers are listed by UL and C-UL, and NYC Approved (MEA 335-01-E) for use as a "Specific Application Window Sprinkler" and as open sprinklers for "Out- side" use. These sprinklers are also recognized by the Interna- tional Code Council Evaluation Service, Underwriters Laborato- ries of Canada (ULC), and the Building Materials Evaluation Commission (BMEC) for use in the Province of Ontario, Canada as providing a two-hour equivalency for a fire separation assem- bly, when installed in accordance with the NES Report (NER 516), ULC/ORD-C263. 1 Appendix A, and BMEC Report (01-11- 263). NOTE NER 516 can be obtained at www.icc-es.org. ULC/ORD-C263. 1 Appendix A and BMEC 01-11-263 may be obtained by contact- ing Technical Services. Area Of Use: When acceptable to the Authority Having Jurisdiction and unless modified by one of the reports mentioned above, the Model WS Specific Application Window Sprinklers may be used in either a sprinklered or unsprinklered building to protect nonoperable window openings that are part of a fire separation provided: in an interior fire separation, the window sprinklers are in- stalled on both sides of the window in the fire separation. (Ref. Figure 3A-1), in jurisdictions where exterior spatial separation (i.e., separa- tion from adjacent space) is defined as protecting an adjacent building from a fire in your building, window sprinklers are installed on the interior side of the building (Ref. Figure 3A-2), or in jurisdictions where exterior spatial separation is defined as protecting your building from a fire in an adjacent building (i.e., exposure protection), open window sprinklers are installed on the exterior side of the building (Ref. Figure 3A-3). System Type: Interior Protection - Wet Systems. Outside Exposure Protection - Deluge. Glass Type: Non-opererable, heat-strengthened, tempered, single-glazed (single pane); non-opererable, heat-strengthened, tempered, double-glazed (double pane or insulated); or, non-opererable, stronger glass window assemblies. In all three cases, each individual pane of the window assembly is to be minimum 6 mm (1/4') thick. Type of Window Frame/Mullion: Noncombustible Frame with a standard EPDM rubber gasket seal. Vertical joints of glass panes must be connected by butt- joints sealed with a silicone sealant between the individual panes or by Noncombustible Mullions (Ref. Figure 313-1 & 313-2). Maximum Length Of Window Assembly: Unlimited. Maximum Height Of Window Assembly: 13' (3,96 m) (Ref. Figure 3C & 3D). Maximum Distance Between Window Sprinklers: 8' (2,44 m) (Ref. Figure 313-1 & 313-2). Minimum Distance Between Window Sprinklers: 6' (1,83 m) (Ref. Figure 313-1 & 313-2), unless separated by a baffle or mullion of sufficient depth to act as a baffle. (A mullion will act as a baffle, when in the case of the Pendent Vertical Sidewall, the mullion extends to the back of the sprinkler deflec- tor, and in the case of the Horizontal Sidewall, the mullion extends to the sprinkler wrench flat.) Minimum Distance From Standard Sprinklers: 6' (1,83 m) unless separated by a baffle. Sprinkler Location: Mullioned Glazing Assemblies - Locate window sprinklers within each mullioned glazing segment (Ref. Figure 313-1). Butt Jointed Glazing Assemblies - Locate window sprinklers on maximum 8' (2,44 m) centers (Ref. Figure 3-B-2). Maximum Distance From Vertical Mullion: 4(1,22 m) (Ref. Figure 313-1). Minimum Distance From Vertical Mullions: 4" (101,6 mm) (Ref. Figure 3B-1). Intermediate Horizontal Mullions: Intermediate Horizontal Mullions were not tested with the win- dow sprinkler. Their use is outside the scope of the "Specific Application" Listing for the window sprinklers (Ref. Figure 313-3). Deflector Location: Sprinkler Deflectors must be located as described below in order to ensure that the entire surface of the glass window is covered. Sprinkler Deflectors are positioned with respect to the window frame, not the ceiling. Horizontal Sidewall - Locate within the outside edge of the window frame from 1/2' to 4 (112,7 mm to 101,6 mm) away from the glass and 2" ± 1" (50,8 mm ± 25,4 mm) down from the top of exposed glass (Ref. Figure 3C). Pendent Vertical Sidewall - Locate 4' to 12" (101,6 mm to 304,8 mm) from the face of the glass and 3' ± 1(76,2 mm ± 25,4 mm) down from the top of exposed glass (Ref. Figure 3D). Minimum Clearance From Face Of Glass To Combustible Materials: All combustible materials shall be kept 2" (50,8 mm) from the front face of the glass. This can be accomplished by a minimum 36" (914,4 mm) pony wall or other method acceptable to the Authority Having Jurisdiction. Escutcheon Assemblies: The window sprinklers can be used with any metallic flush or extended escutcheon, provided the dimensions from the sprin- kler deflector to the window frame and glass surface as specified in this data sheet are maintained. These sprinklers are not listed for recessed applications. Recommended Hydraulic Requirements: The Authority Having Jurisdiction should be consulted to deter- mine the hydraulic requirements for each installation. Interior Protection Sprinklered Building - Identify which compart- mented area has the most hydraulically demanding window sprinklers. Calculate all of the sprinklers within a compartmented area or the number of window sprinklers required to cover a combined linear length of glass equal to 1.2 x the square root of the system area of operation, whichever is greater. For example if the building design area is 1500 ft2 then 1.2 x (1500 ft2)112 = 46.5 linear feet of glass or 1.2 x (139 rn2)112 = 14,2 linear meters of glass. Add the window sprinkler demand to your most de- manding hydraulic design area. Interior Protection Non-Sprinklered - Calculate all the sprinklers on the most demanding side of the glazing assembly within the enclosure. Exterior Exposure Protection - Calculate all sprinklers controlled by the deluge valve using the design requirements of NFPA. Duration Of Water Supply: The duration of the water supply must comply with the require- ments of NFPA. In the event the window sprinklers are being used to provide the equivalency of a fire rating, the water supply must be capable of supplying water for the required rating period. Minimum Flow Per Sprinkler: 20 GPM (75,7 LPM) for sprinkler spacing of 6 to 8 ft. (1,83 to 2,44 m) or 15 GPM (56,8 mLPM) for sprinkler spacing less than 6 ft, (1,83 m). Maximum Pressure Per Sprinkler: Horizontal Sidewall = 70" psi (4,83 bar). Vertical Sidewall = 175 psi (12,07 bar). "The 70 psi is only for cold solder purposes. If there is a baffle or mullion of sufficient depth to act as a baffle, separating the sprinklers, the maximum pressure is 175 psi. Page 4 of 8 TfP62O' Installation The Model WS Specific Application Window Sprinklers must be installed in accordance with the following instruc- tions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6mm). A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 20 ft. lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Step 1. The pendent vertical sidewall sprinkler must be installed only in the pendent position with the centerline of the sprinkler parallel to the glass sur- face. The sprinkler must be orientated so that the direction of flow indicated on the sprinkler deflector is facing the window. The horizontal sidewall sprin- kler must be installed only in the hori- zontal position with the centerline of the sprinkler perpendicular to the glass surface. The sprinkler must be orien- tated so that the word "Top" indicated on the sprinkler deflector is facing the top of window frame. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten the Sprinkler using only the W-Type 20 (End A) Sprinkler Wrench (Ref. Figure 4). The W-Type 20 (End A) Sprinkler Wrench is to be applied to the Sprinkler Wrench flats only. When acceptable to the Authority Having Jurisdiction the Model WS Specific Application Window Sprinklers may be used in either a sprinklered or unsprinklered building to protect nonoperable window openings that are in an interior fire separation, the window sprinklers are installed on both sides of the window in the fire separation. INSIDE C' INSIDE FIGURE 3A-1 - INTERIOR FIRE SEPARATION When acceptable to the Authority Having Jurisdiction the Model WS Specific Application Window Sprinklers may be used in either a sprinklered or unsprinklered building to protect nonoperable window openings that are part of a fire separation provided in jurisdictions where exterior spatial separation is defined as protecting an adjacent building from a fire in your building, window sprinklers are installed on the interior side of the glass. OUTSIDE INSIDE EXPOSURE SIDE FIGURE 3A-2 - EXTERIOR FIRE SEPARATION - SPRINKLERS INSIDE WIen acceptable to the Authority Having Jurisdiction the Model WS Specific Application Window Sprinklers may be used in either a sprinklered or unsprinklered building to protect nonoperable window openings that are part of a fire separation provided in jurisdictions where exterior spatial separation is defined as protecting your building from a fire in an adjacent building, open window sprinklers are installed on the exterior side of the glass. \ INSIDE C' C' C' -. OUTSIDE EXPOSURE SIDE FIGURE 3A-3 - EXTERIOR FIRE SEPARATION - SPRINKLERS OUTSIDE FIGURE 3A TYPICAL NONOPERABLE WINDOW OPENINGS TFP62O Page 5 of 8 HORIZONTAL 6-0' (1,83 m) OR VERTICAL 8-0" (2,44 m) MINIMUM MODEL WS MAXIMUM SPRINKLER * Minimum distance between Window Sprinklers is 6-0' 4-0" (1,22 m) MAXIMUM MULLION - (1,83 m) unless separated by a baffle or mullion of 0-4" (101,6 mm) MINIMUM sufficient depth to act as a baffle. X/I A Window Sprinkler must be provided at each window glazing segment, regardless of width of segment. If segment is less than 6-0". a baffle or mullion to act as a baffle must be provided. FIGURE 3B-1 - MULTIPLE WINDOWS SEPARATED BY MULLIONS _ I _ 6-0(1,83 m) MINIMUM Window Sprinklers are NOT required to be located with BUTT JOINT respect to horizontal or vertical butt joints. I h& / A HORIZONTAL OR VERTICAL 8-0" (2,44 m) MODEL WS MAXIMUM SPRINKLER MULLION 4-0" (1,22 m) MAXIMUM 0-4" (101,6 mm) MINIMUM 'X/ FIGURE 3B-2 - MULTIPLE WINDOWS SEPARATED BY BUTT JOINTS I I n Ii' HORIZONTAL OR VERTICAL MODEL _- MULLION WS SPRINKLER Window Sprinklers are NOT listed to protect windows INTERMEDIATE when intermediate horizontal mullions are present. MULLION Figure 3B-3 - WINDOWS WITH HORIZONTAL MULLIONS FIGURE 3B WINDOW MULLIONS AND BUTT JOINTS Page 6 of 8 TcP62O "TOP" INDICATED ON SPRINKLER - DEFLECTOR BUILDING STRUCTURE NO MAXIMUM DISTANCE WINDOW FRAME - 2(50,8 mm) NO ± 1(25,4 mm) MAXIMUM HEIGHT 1/2"(12,7mm) ALL COMBUSTIBLE TO 4" (101,6 mm) MATERIALS SHALL BE KEPT 2(50,8 mm) MINIMUM FROM SPRINKLERED FACE 134 NONOPERABLE - OF GLAZING. THIS MAY BE (3,96 m) GLASS WINDOW DONE THROUGH USE OF MAXIMUM MINIMUM 34 (0,9 m) EXPOSED "PONY WALL', OR BY GLAZING INSTALLATION NOTE: ANY OTHER METHOD HEIGHT SPRINKLER SHALL ACCEPTABLE TO THE BE ORIENTED WITH AUTHORITY HAVING FRAME ARMS ALIGNED JURISDICTION. VERTICALLY AND MARKED SIDE OF DEFLECTOR FACING AND PARALLEL MODEL WS SPRINKLER TO GLAZING SHOWN ON ONE SIDE OF GLAZING FOR CLARITY. FIGURE 3C MODEL WS HORIZONTAL SIDEWALL SPRINKLER TYPICAL INSTALLATION Care and Maintenance The Model WS Specific Application Window Sprinklers must be main- tained and serviced in accordance with the following instructions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFP62O Page 7 of 8 FIGURE 3D MODEL WS VERTICAL PENDENT SIDEWALL SPRINKLER TYPICAL INSTALLATION CENTERLINE OF SPRINKLER WATERWAY FLOW DIRECTION INDICATED ON SPRINKLER DEFLECTOR NO MAXIMUM HEIGHT 4(101,6mm) TO 12" (304,8 mm) 13-0 NONOPERABLE (3,96 m) GLASS WINDOW MAXIMUM EXPOSED GLAZING INSTALLATION NOTE: HEIGHT SPRINKLER SHALL BE ORIENTED WITH FRAME ARMS ALIGNED PARALLEL TO GLAZING AND DEFLECTOR FLOW ARROW POINTED TOWARD GLAZING Limited Warranty Products manufactured by Tyco Fire & Building Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire & Building Products. No warranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire & Building Products or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applica- ble Standards of the National Fire Pro- tection Association, and/or the stand- ards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire & Building Products to be defec- tive shall be either repaired or re- placed, at Tyco Fire & Building Prod- ucts' sole option. Tyco Fire & Building Products neither assumes, nor author- izes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire & Building Products shall not be responsible for sprinkler system de- sign errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE & BUILDING PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LI- ABILITY OR UNDER ANY OTHER LE- GAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE & BUILDING PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE & BUILDING PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. GIi;I*!.JHcY;i;VkiJDE BUILDING STRUCTURE NO MAXIMUM DISTANCE WINDOW FRAME 3(76,2 mm) ± 1(25,4 mm) ALL COMBUSTIBLE MATERIALS SHALL BE KEPT 2" (50,8 mm) MINIMUM FROM SPRINKLERED FACE OF GLAZING. THIS MAY BE DONE THROUGH USE OF MINIMUM 3-0" (0,9 m) "PONY WALL", OR BY ANY OTHER METHOD ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. MODEL WS SPRINKLER SHOWN ON ONE SIDE OF GLAZING FOR CLARITY. OR IMPLIED, INCLUDING WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR- POSE. Page 8 of 8 RECESSED CEILING SPACE BUILDING STRUCTURE WINDOW FRAME INSTALLATION NOTE: ALL COMBUSTIBLE VERTICAL AND MATERIALS SHALL BE HORIZONTAL MODEL KEPT 2(50,8 mm) MINIMUM WS SPRINKLERS FROM SPRINKLERED FACE MAY BE INSTALLED OF GLAZING. THIS MAY BE INTO RECESSED DONE THROUGH USE OF TYPICAL WINDOW CEILING SPACES. MINIMUM 34" (0,9 m) COVERING BLINDS, CURTAINS "PONY WALL', OR BY OR OTHER WINDOW ANY OTHER METHOD COVERINGS SHALL ACCEPTABLE TO THE NOT BE LOCATED AUTHORITY HAVING BETWEEN SPRINKLER JURISDICTION. AND GLAZING NONOPERABLE - MODEL WS SPRINKLER ' GLASS WINDOW SHOWN ON ONE SIDE OF GLAZING FOR CLARITY. \ FIGURE 3E MODEL WS VERTICAL PENDENT SIDEWALL SPRINKLER RECESSED CEILING TYPICAL INSTALLATION TFPG2O Ordering Procedure Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: Model WS, (Specify SIN), (specify Horizontal or Vertical Pen- dent) Specific Application Window Sprinkler, with (specify temperature rating), (specify finish), PIN (specify). WS (TY3388) Horizontal Sidewall Window Sprinkler 155°F/68°C, Natural Brass...........P/N 50-305-1-155 155°F/68C, Chrome Plated .........P/N 50-305-9-155 155°F168°C, White Coated...........P/N 50-305-4-155 155°F/6&C, White RAL9010*P/N 50-305-3-155 200°F/93°C, Natural Brass...........P/N 50-305-1-200 200°F193°C, Chrome Plated .........P/N 50-305-9-200 200°F/93°C, White Coated...........P/N 50-305-4-200 200°F193°C, White RAL9O1O*P/N 50-305-3-200 WS (TY3488) Vertical Pendent Sidewall Window Sprinkler 155F/68°C, Natural Brass...........P/N 50-304-1-155 155°F/68°C, Chrome Plated .........P/N 50-304-9-155 155°F/68°C, White Coated...........P/N 50-304-4-155 155°F/68°C, White RAL9010*P/N 50-304-3-155 200°F/93°C, Natural Brass...........P/N 50-304-1-200 200F/93°C, Chrome Plated .........P/N 50-304-9-200 200°F/93°C, White Coated...........P/N 50-304-4-200 200°F/93°C, White RAL9010*P/N 50-304-3-200 * Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 20 Sprinkler Wrench, P/N 56-000-1-106. WR ENCH RECESS (USE END "A" FOR MODEL WS) FIGURE 4 W-TYPE 20 SPRINKLER WRENCH TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Manufactured by: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product lug Description The Central Two-Piece Adjustable Sprinkler Escutcheon is designed to enhance the appearance of pendent sprinklers when installed below ceilings. The escutcheon provides a decorative closure of the annular space between the sprinkler and the ceiling. The Two-Piece Adjustable Sprinkler Escutcheon is of a telescoping type design that provides for 2" of field adjustment, thereby assuring a good fit against the ceiling. It is available in two thread sizes and three standard finishes. Additional special finishes are available upon request which require additional ordering time and a special paint charge. Technical Data Model: 401 Style: Two-Piece Adjustable Escutcheon Size: 1/2U (12.7 mm) or 3/4' (19.1 mm) N.P.T. Standard Finishes: Brass, Chrome and White Depth: Minimum: 1¼' (47.6 mm) Maximum: 31/8" (79.4 mm) Diameter: Cup: 21/4" dia. (57.15 mm) Skirt: 3W dia. (88.9 mm) Weight: 2.8 oz. (79.4 grams) Installation The Two-Piece Adjustable Sprinkler Escutcheon is held in the proper position by being sandwiched be- tween the face of the reducing coupling and the wrench boss on the sprinkler. Installation Sequence: Step 3. Hand tighten the sprinkler and cup into the reducing coupling on the drop nipple. Step 4. Wrench tighten the sprinkler to the recommended torque using the proper Central Sprinkler Wrench. Step 5. After the ceiling is in place, align the escutcheon skirt with the sprinkler and press it up and over the escutcheon cup until the outer edge of the skirt meets the ceiling surface. Step 1. The face of the reducing coupling on the drop nipple should be a nominal 21/4" (±W) below the finished ceiling surface. Step 2. Prior to installation of the sprinkler, turn the escutcheon cup onto the sprinkler threads. Cross Section - Two-Piece Sprinkler Escutcheon - 401 fl Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the model, size and quantity. Availability and Service: Central sprinklers, valves, accessories, and other products are available throughout the U.S. and Canada; and internationally through a network of Central Sprinkler distribution centers. You may write directly to Central Sprinkler Company or call (215) 362- 0700 for the distributor nearest you. Guarantee: Central Sprinkler Company will repair and/or replace any products found to be defective in material or workmanship within a period of one year from the date of shipment. Please refer to the current Price List for further details of the warranty. Conversion Table: 1 inch = 25.400 mm Conversions are approximate. CENTRAL IMMEMEMM- Central Sprinkler Company 451 North Cannon Avenue, Lansdale, PA 19446 © 1992 Central Sprinkler company Phone (215) 362-0700 Printed in U.S.A. FAX (215) 362-5385 401.1 Technical Data Model: Sprinkler Head Cabinet Style: 3, 6 or 12 head Standard Finish: Red enamel Mfgr. Source: Non-domestic Capacity: 3 sprinkler heads 6 sprinkler heads 12 sprinkler heads Dimensions: 3 head - 5" high x 71/2' long x 2W' deep 6 head - 5" high x 14" long x 3Y4" deep 12 head - 5" high x 141/4" long x 5" deep Weight: 3 head - 1.5 lbs. 6 head - 2.3 lbs. l2 head -4lbs. 3r 6 & 12 Head Sprinkler Head Cabinet '.- .- - - S S 0 V Sprinkler Head Cabinet Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 L T ! Product Description Central Sprinkler Head Cabinets are constructed of a metal enclosure with a hinged cover designed to provide on-site storage of an emergency supply of sprinkler heads and a sprinkler head wrench. NFPA 13 requires a representative number of each type of sprinkler head used in a sprinkler system to be stored in a cabinet on-site to allow for immediate removal and replacement of sprinklers which may have operated or become damaged. Central Sprinkler Head Cabinets are manufactured of heavy gauge steel with knock-outs to accommodate either 1/21 or 3/4" N.P.T. threaded sprinkler heads and are painted an attractive red enamel. They are available in three (3), six (6) or twelve (12) head capacity. No. 28.6.0 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 001/020 SWAY BRACE FITTING — MODEL E Part #077 SIZE - Sprinkler systems pipe: 1" thru 8" Steel Schedule 7 thru 40. SIZE - Sway brace assembly pipe: Steel 1" and 1 1/4" Schedule 40 MATERIAL - Carbon Steel or S.S. (Type 304). FINISH - Plain, E.G., and H.D.G. LISTINGS *us EX 2625 Listed only for use with other AFCON bracing products. OSHPD pending. PATENT - No. 3,570,794 FUNCTION - Per NFPA 13. Sway brace fitting of a lateral sway brace assembly. To form a 4-way, arrange adjacent lateral sway braces. INSTALLATION - Per NFPA 13. Place Model E over pipe to be braced. Insert brace pipe through MODEL "B' under channel bracket, leaving P minimum extension beyond. Tighten hex nuts until gage spring lays flat or torque to 65 in.-lbs. ASSEMBLY - Per NFPA 13. Combine with AFCON 70 series structure sway brace fitting and pipe brace element forming a complete sway brace. FEATURES * UL Horizontal Load Ratings for all sizes Sch. 10 thru 40 = 2015# * UL Horizontal Load Ratings for 1" thru 4" Sch. 7 = 655# * UL Horizontal Load Ratings for 6" Sch. 7 = 1500# * Visual inspection, proper installation when gage spring lays fiat. ORDERING - Part #, pipe size to be braced, brace pipe size and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a fisted sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shalt NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not united to loss of business or profit, when non-AFCON products have been, or are used. 11/06 Component of State of Fig. 909 - No-Thread Swivel Sway Brace Attachment Size Range - 1" bracing pipe. For brace pipe sizes larger than 1, use TOLCO Fig. 980. Material - Carbon Steel, hardened cone point engaging screw Function - The structural component of a sway and seismic bracing system. Features -This product's design incorporates a concentric attach- ment opening which is critical to the performance of structural seismic connections. NFPA 13 (1999 Edition) Table 6-4.5.9 indicates clearly that fastener table load values are based only on concentric loading. No threading of the bracing pipe is required. Open design allows for easy inspection of pipe engagement. All steel construction eliminates deficiencies associated with malleable type attachments. Fastener can be mounted to all surface angles. Application Note - The Fig. 909 is used in conjunction with the TOLCO Fig. 1000, Fig. 1001, or Fig. 4 (A) pipe clamp, and joined together with bracing pipe. Install per NFPA 13 and/or TOLCO State of California OSHPD Approved Seismic Restraint Manual. The required type, number and size of fasteners used for the structure attachment fitting shall be in accordance with NFPA13 and/or OSHPD. Installation - Extend bracing pipe through opening. Tighten cone point engaging screw until head bottoms out or minimum torque 23 ft/lbs. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, pipe size and finish. Important Note - The Fig. 909 is precision manufactured to perform its function as a critical component of a complete bracing assembly. Sway brace assemblies are intended to be installed in accordance with NFPAI3 and the manufacturer's installation instructions. To ensure performance, the UL Listing requires that the Fig. 909 must be used only with other TOLCO bracing products. NATIONAL AND INTERNATIONAL PATENT APPLICATION IN PROCESS. Dimensions • Weights Max. Design. Max. Design Load Approx. Pipe Size A B H* Load Lbs. Lbs. wlWasher Wt./100 1 6 V/6 17/32 2015 2765 91 * Available with hole sizes to accommodate up to 3/4" fastener. Consult Factory. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951 737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 1hI4 Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8', 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4"(Fig. 65) or 11/411 (Fig. 66). Features - All steel construction eliminates structural deficien- cies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 411 pipe, 1/2" rod will support 1/2" thru 8" pipe. Finish - Plain Note - Available in Electro-Ga Ivan ized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./1 00 3/8 1 /16 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 1/4 1130 55 5/8 1/2 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1'/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 1'/4 1130 55 5/8 11/2 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. - OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 wwwtolco.com P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 076 ATTACHMENT FITTING UNIVERSAL LOCKING SIZE - Fits 1 thru 2 inch bracing pipe, strut channel and structural steel. Use in combination with I thru 10 inch AFCON sway brace assemblies. MATERIAL - Ductile iron or Carbon Steel. FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - 203A-EX 2625 Listed only for use with other AFCON bracing products. Approval Pending OSHPD OPA-0601 See Website. PATENT - Pending. FUNCTION - Structure attachment fitting of a sway brace assembly, consisting additionally of AFCON 001 thru 040 sway brace fitting and brace element of 3/8" maximum thickness forming a complete sway brace assembly. INSTALLATION - Per NFPA 13. Listed for use with NFPA 13 fastener tables. For installation on H-beam or steel web joist use AFCON 085 thru 088 sway brace adapters. ASSEMBLY -Insert brace component into fitting snug against back of jaw. Install set bolt finger tight, then additionally tighten 1/2 turn or torque to 125 inch pounds. FEATURES * UL Horizontal Load Rating: 076D Ductile Iron = 2765# 076S Steel = 2015# * Swivel design allows attachment at any angle. * Visual inspection, proper installation when set bolt head contacts body. ORDERING - Part #, pipe size, material and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, orate used. 2/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 085 SWAY BRACE ADAPTER STEEL WEB JOIST Radius - Tapped I/2"orficc SIZE - 1/2 inch through bolt. MATERIAL- Carbon Steel. FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - 203A-EX 2625, 203-EX 2551 Listed only for use with other AFCON bracing prodi OSHPD OPA-0601 See Website. PATENT - No. 6,749,359 FUNCTION - Sway brace adapter used to attach an AFCON sway brace assembly to a steel web joist structural member. To provide a point of connection when drilling is not allowed or impractical. To stabilize 1/2" threaded stud in chord space. INSTALLATION - Per NFPA 13 and structural building component manufacturers recommendations. Steel Web Joist Manufacturer's warranty requires attachment within 6" of chord panel point. Per drawing, assemble 1/2" threaded stud thru chord space into tapped part B. Install part A over stud, engage AFCON sway brace assembly and nut. Install nut finger tight, then additionally tighten 1/2 turn or torque to 40 ft. Lbs. * 1/2" threaded stud and nut furnished by customer. FEATURES * UL load ratings at 30° thru 90° horizontal: Perpendicular to beam - 2015# Parallel to beam - 2015# * Radius - Tapped 1/2" orifice facilitates fast thread engagement. * UL listed hanger attachment for 8" pipe. ORDERING - Part # and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 5/08 SIZE RANGE - 1/2" Rod. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and H.D.G. LISTINGS - *us EX 2625, EX 2551 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org SWAY BRACE ADAPTER WIDE FLANGE I I-BEAM Listed only for use with other AFCON bracing products. OSHPD pending. PATENT - No. 6,334,285 FUNCTION - Sway brace adapter used to attach an AFCON sway brace assembly to a wide flange or I-Beam steel structural member. To provide a point of connection when drilling is not allowed or impractical. Also can be used to attach to a steel web joist with a formed top chord. (See Drawing) INSTALLATION - Per NFPA-13. Per drawing, insert 1/2" x 1 1/4" attachment bolt into 086 bracket. Install 1/2" threaded studs thru both brackets and engage on steel flange. Assemble nuts on studs and tighten. Install nuts finger tight, then additionally tighten V2 turn or torque to 40ft. Lbs. Attach AFCON sway brace assembly on 1/2" bolt. On steel web joist with formed top chord install within 6" of the panel points. * 1/2" threaded studs and fasteners furnished by customer. FEATURES * UL load ratings at 300 thru 900 horizontal: Perpendicular to beam - 2015# Parallel to beam - 1265# * Universal, any flange width having thickness of 1/4" thru 1 1/411. * Studs capture head of bolt, providing hold back. * Alternative to center loading beam clamp. * UL listed hanger attachment for 8" pipe. ORDERING - Part # and finish. Specific .'IFCON products are exclusively designed to be compatible ONLY with other 4FCON products including pans and fasteners, resulting in a listed sway brace, restrainer or banger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss or business or profit, when non-AFCON products have been, or are used. 7/06 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org [II1 SWAY BRACE ADAPTER STEEL WEB JOIST SIZE - 1/2 to 7/8 Through Bolt MATERIAL - Carbon Steel FINISH - Plain, E.G. and H.D.G. LISTINGS - c®us EX 2625, EX 2551 Listed only for use with other AFCON bracing products. OSHPD pending. PATENT - 6,464,422 FUNCTION - Sway brace adapter used to attach an AFCON sway brace assembly to a steel web joist structural member. To provide a point of connection when drilling is not allowed or impractical. INSTALLATION - Per NFPA- 13 and structural building component manufacturers recommendations. Steel Web Joist Manufacturer's warranty requires attachment within 6" of chord panel point. Per drawing, engage flared edge tight to underside of steel top chord, drill nominal 21/2 x 5 wood nailer, install 1/2" threaded stud thru brackets engaging AFCON sway brace assembly under nut. * 1/2" threaded stud and nuts furnished by customer. FEATURES * UL load ratings at 30° thru 900 horizontal, using 1/2 through bolt: Perpendicular to beam- 1400# Parallel to beam - 1400# * UL horizontal load rating: 2015# maximum when installed with larger through bolts per NFPA- 13. * Furnished with 1/2" rod hole. * UL listed hanger attachment for 8" pipe. ORDERING - Part #, Finish. Specify custom hole size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a 1sted sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shalt NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 7/06 Fig. 4 - Standard Pipe Clamp Fig. 4F - Standard Pipe Clamp Felt Lined Fig. 4PVC - Standard Pipe Clamp PVC Coated Size Range - (Fig. 4) Size 1/2' thru 30' pipe. Size Range - (Fig. 4F) Size 1/2' thru 2V2" copper tubing Material - Carbon Steel Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shields. (Use Fig. 330 Weldless Eye Nut, Fig. 102 Eye Rod or Fig. 101 Welded Eye Rod.) Also recommended for attachment of sway bracing up to 31/2" pipe size, for larger pipe sizes use Fig. 4A. Fig. 4F and Fig. 4PVC are designed to reduce noise and vibration and/or prevent electrolysis. Approvals - Underwriters' Laboratories Listed in the USA (UL), Canada (cUL) 3/4" - 81., and approved by Factory Mutual Engineering, 3/4" -8". Federal Specification WW-H-171E, Type 4, 11/2" thru 24" and Manufacturers Standardization Society SP-69, Type 4. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spac- Fig. 4 ing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note - When the Fig. 4 is used as a sway brace, to ensure perform- ance, the UL Listing requires that it must be used with other ./ TOLCOTM brace products. Maximum Temperature —750°F I' . Finish — Plain , ' /. 9' Note — Available in Electro-Galvanized and HDG finish or Stainless ..-.. Steel materials. Order By — Figure number, pipe size and finish. Fig. 4F Order Note — When ordering Fig. 4F allow for 3/16" felt on each half of clamp. Fig. 4PVC Dimensions • Weights Max. Design Load Lbs. Pipe For Service Temp. Size A B C D Bolt Size 6500 750°F Approx. Wt./100 1/2 3 /16 1/4 11/8 11/8 5/16 500 445 29 3/4 3°/ 1/4 1'/4 11 /4 5/16 500 445 31 1 3°/,6 1/4 1 /4 1/1 5/16 500 445 35 1'/4 4 /16 1/2 13/8 111/16 5/16 500 445 40 1 /2 49/,6 5/16 15/s 1/ 5/16 800 715 42 2* 5 /16 1/2 2 21/4 3/8 1040 930 93 21/2* 6/,6 9/16 21/2 2/4 1/2 1040 930 126 3* 7 5/8 2/4 31/16 1/2 1040 930 141 31/0 711/16 3/8 31/ 3 /8 1/2 1040 930 154 4 81/2 5/8 311/16 5/8 1040 930 229 5 3/4 37 4/ 5/8 1040 930 261 6 11 /8 3/4 47/s 51/ 3/4 1615 1440 537 8 13/16 1 55/s 6 3/4 1615 1440 625 10 161/2 1 71/ 71/4 7/8 2490 2220 1378 12 181/2 1 8'/4 81/4 7/8 2490 2220 1574 14 20 11/8 9 9 7/8 2490 2220 2103 16 23 11/8 10'/4 10'/4 7/8 2490 2220 2314 18 25/ 11/4 111/9 111/, 1 3060 2730 3276 20 28 1 /8 121/2 121/2 1'/ 3060 2730 3863 24 331/ 1/ 151/4 151/4 1 /4 3060 2730 5222 30 41 /8 2 19 19 1/4 3500 3360 10511 *Meets UL 203A requirements for attachment of sway bracing. Horizontal design load for 1/2-2" - 380#, 21/2" - 395#, 3" - 435#, 31/2" - 540# Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 wwwto!co.com Fig. 4A - Pipe Clamp for Sway Bracing Size Range - 4" thru 8" pipe. For sizes smaller than 4" use TOLCOTM Fig. 4. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) 4" thru 8". Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health: Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions - Install Fig. 4A Pipe Clamp on pipe to be braced. Attach Sway-Brace Fitting to 1/2" Clamp bolt (Sway-Brace Fitting to be on out- side ears of clamp). Tighten securely. (mm. torque requirement - 50 ft. lbs.) Sway Brace Assemblies are intended to be installed in accordance with NFPA 13 and the Manufacturers Installation Instructions. Finish - Plain Note - Available in Electro-Ga Ivan ized and HDG finish or Stainless Steel materials. Order By - Figure number, pipe size and finish scs Component of State of California OSHPD Approved Seismic Restraints System Fig. 4A - Longitudinal Brace Fig. 4A - Brace Dimensions • Weights Pipe Max. Horizontal Approx. Sizes A B C D Bolt Size Design Load Wt./100 4 84/2 9/16 33/s 311/, 1/2 2015 221 5 93/4 9/16 37/s 43/8 1/2 2015 253 6 111/2 5/8 5 51/ 1/2 2015 513 13'/4 3/4 6 /16 61/a 1/2 2015 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.folco.com 601 27: Fig. 4L Longitudinal "In-Line" Sway Brace Attachment Size Range - 21/2 ' through 8' lPS. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. Approvals - Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) 21/2 ' - 8'. Approved by Factory Mutual Engineering (FM), 21/2" - 8" pipe. Installation Instructions - The Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, pipe size and finish. 4-Way Riser Brace (Plan view) Dimensions • Weights Longitudinal Brace B olt Max. Rec. Max Rec. Approx. Sizes A C D Size Load Lbs. Load Lbs. wtjloo (cULus) (FM) 21/2 6A6 21/2 23/4 1/2 2015 3000 253 3 7 23/4 31/16 1/2 2015 1550 268 4 81/2 33/8 311A6 1/2 2015 1550 348 5 93/4 3/8 43/8 1/2 2015 1450 380 6 111/2 5 51/8 1/2 2015 1450 640 8 131/4 611A6 61/8 1/2 2015 1450 728 * Load shown is allowable with brace installed, between 300 - 90'.No reduction of load based on brace angle is required. FM approved when used with 1', 11/4 , 11/2 ' or 2 Sch. 40 brace pipe. TOLCO® brand bracing components are designed to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such ToLco® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer Size Range - One size fits 3/4 thru 2" pipe. Material - Steel Function - Designed to be used in conjunction with TOLCOTM Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the bank hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed jy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, n the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4' thru 2". Patent #5,344,108 Office/Manufacturing Facility • 1315 Sampson Ave. • Corona, CA 92879 • Ph: 951737.5599 • Fax: 951.737 0330 Customer Service • 800.786.5266 wwwtolco.com Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range - 3/8' and 1/2' rod; 4" thru 16' length.** Material - Pre-Galvanized Steel Function -To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 64.7.1. Features - Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in section "A-A" or inverted. Allows easy installation for new construction or retrofit applications. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mecha- nism of some kind, such as the beveled locking slot of the Fig. 69R or a hex nut tightened against other types of retaining straps will provide a more secure and reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, rod or set screw size and length Note - Minimum return on Strap: 1". * Patent #5,947,424 Dimensions • Weights Rod Size A Length 3/8" Specify 1/2" Specify Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fan: 951.737.0330 Customer Service • 800.7865266 wwwfolco.com Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range - Secures 3/8' thru 7/8 hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750° F Finish - Plain Note - Available in Electro-Ga Ivan ized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1 /4 8000 7140 360 11/2 11630 10370 510 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 851.737.5599 • Fax: 951.37.0330 Customer Service • 800.786.5266 wwwtolco.com 2 1/2 ThPJ INCH PIPE 1 2 THRU 2 INCH PPE Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2 thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200 WON. Order By - Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31/ 21/8 400 11 3/4 3/8 8mm or 10mm 31/ 21/2 400 11 1 3/8 8mm or 10mm 33/s 25/s 400 12 1 /4 3/8 8mm or 10mm 33/4 2/ 400 13 11/2 3/8 8mm or 10mm 37/s 2/ 400 14 2 3/8 8mm or 10mm 41/ 3 400 15 21/2 3/8 10mm 55/s 41/ 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 7 /8 51/4 600 34 4 3/8 10mm 73/s 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 6/., 1250 73 8 1/2 12mm 131/ 8/ 1250 136 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 wv,,wtolco.com Fig. 200H - Heavy Duty Band Hanger (for Trapeze) 001111811W11111111 Size Range - 2" thru 4" trapeze pipe size. Used to support up to 8" pipe. For 6" and 8" trapeze pipe, consult factory. Material - Carbon Steel - Pre-Galvanized to G40 Spec Function —Designed primarily to support substantially heavier loads than is normally - intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features - Furnished with 3/8" or 1/2" adjusting threaded ring nut. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Pre-Galvanized Order By - Figure number, pipe size and rod size. Important Design Note - Because of the increased loads applied to the trapeze assem- bly, Ph the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended*. Dimensions • Weights Trapeze Rod Size **Max. Rec. Pipe Size Size A B Load Lbs. 2 3/8 4A6 3/32 1250 2 1/2 423/32 33/8 1250 21/2 3/8 55A6 323/32 1250 21/2 1/2 515/32 37/8 1250 3 3/8 53/4 327/32 1250 3 1/2 5/8 331/32 1250 4 3/8 6/8 4/is 1250 4 1/2 71/32 419/32 1250 Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13 (2002) Table 9.1.1.6.1 (a and b) All sizes are UL Listed to support up to 8 pipe at max spacing per NFPA 13 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 410 SWAY BRACE FITTING Part #077-........ rt# 078 SIZE — I thru 8 inch pipe. MATERIAL - Carbon Steel or S.S. (Type 304). FINISH — Plain, E.G., and H.D.G. LISTINGS — cus EX 2625, EX 2551 Listed only for use with other AFCON bracing products. OSHPD pending. FUNCTION — Pipe attachment component of a longitudinal or 4-way sway brace, consisting additionally of AFCON 70 series attachment end, AFCON 80 series adapter as required and brace pipe element forming a complete sway brace assembly. INSTALLATION — Per NFPA-13. Assemble 410 over pipe to be braced, install 70 series attachment end on outside of clamp ears and tighten bolts to minimum required torque of 40 ft.lbs. 078 is the preferred assembly component for use with the 410 - see drawing. FEATURES * UL Horizontal Load Rating: 1-3 pipe size = 500# 4-8 pipe size = 2015# * Made with 1/2" bolts to conform with sway brace fittings. ORDERING — Part #, pipe size and finish. Specific AFCON products are exclusively designed lobe compatible ONLY with other AFCON products including parts and fasteners, resulting In a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or said by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used, 9/06 Fig. 1000 - "Fast Clamp" Sway Brace Attachment Size Range - Pipe size to be braced: 1" thru 6" Schedule 10 thru 40.* Pipe size used for bracing: 1" and 11/4' Schedule 40 IPS. * Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 - 8 ft. lbs. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1000 is used in conjunction with a TOLCOTM Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features - Can be used to brace Schedules 7 thru 40 lPS. Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as longitudinal brace with Fig. 907. All steel construction eliminates structural deficiencies associated with casting type sway brace fittings. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Application Note - Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1' pipe extension beyond the Fig. 1000 is recommended. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spac- ing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Important Note -The Fig. 1000 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 1000 must be used only with other TOLCO bracing products. Component of State of California OSHPD Approved Seismic Restraints System Maximum Design Load 1" thru 4" pipe size —2015 lbs. 6" size - 1265 lbs. Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com SAAIAIYS @) APPROVED 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST20SS X 2-1/2 850 1.5 8010957 GST30 X 4 1500 1.5 X 4 1475 1.5 8009925 GST25-380 X 4 1500 1.5 8022925 SWG 25-380 X 3-1/2 - 4* 1500 1.5 8021957 SWG 20 X 2-1/2 - 3** 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SHGST20 X 3 1050 1.5 X 4 1475 1.5 8141957 SHGST30 X 4 1500 1.5 X 4 1475 1.5 8038957 DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475. 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 8059957 CST 20 X 4 1475 3000 PSI 8061957 SWC20 X 4 1475 3000 PSI * SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2 SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2 ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" A& UL and FM tests were performed in compliance with NFPA-13 Standards. Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. 11117"71J27 Buildex www.itwbuildex.com 800-284-5339 SSS26 0506 44 (e)poTTER VSRF VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50mm thru 200mm). LPC approved sizes are 2" thru 8' (50mm thru 200mm). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC and CSFM Listed, FM and LPCB Approved, NYMEA Accepted, CE Marked Service Pressure: Up to 450 PSI (31 BAR) Minimum Flow Rate for Alarm: IO GPM (38 LPM) Maximum Surge: 18 FPS (5,5 m/s) Contact Ratings: Two sets of SPDT (Form C) 15.0 Amps at 125/250VAC 2.0Ampsat30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2' conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA4/1P54 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/120°F, 4,5°C/49°C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40, sizes 2' thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA- 13D Residential occupancy up to four stories NFPA- 13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2' (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. (68 n-m) of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 www.pottersignat.com PRINTED IN USA MKT. #8800001 - REV W PAGE I OF 2 MFG. #3400761 - 7/02 FIG. 3 TYPICAL ELECTRICAL CONNECTIONS 2 SETS OF NORMALLY OPEN CONTACTS CLOSE ON ALARM co- 10 Ic THE N.C. AND N.O. MARKINGS ON THE SWITCII ARE FOR AN ALARM CONDITION. THE CONTACTS ARE REVERSED WHEN TIIR DEVICE IS IN TIlE NORMAL CONDITION. WATERFLOW ZONE ON FIRE PANEL Post OR NEOATI NEUTRAL AC nWO# 7602 (E)POTTER The Symbol of Protection VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FIG. I SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL DWC.9 923-3 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITH FOR DESIRED TIME DELAY. USE THE AMOUNT OF RETARD NECESSARY TO FALSE ALARMS, A 'B' SETTING IS U ADEQUATE FOR THIS, FACTORY IS TO INSTAl I. 08111 HOI F AS INDICATED PIPE SIZE HOLE SIZE to 2 1/2" 1 1/4" +1/8" (50mm to 65mm) (33mm ±2mm to 8" 2' ±1/8' (80mm to 200mm) 50mm ±2mm) Cover Tamper (with cover in place) C DIRE (WHT) (RED) (BLK) DWG. #761-30 TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL SOFT-LBS (68 n-m) OF TORQUE MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW D SETTINGS (IN SECS.) 711c_ 0E 50 70 60 90 FIG. 2 OPTIONAL TAMPER SWITCH DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME NOTES: The Model VSR-F has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. For supervised circuits see "Switch Terminal Connections" drawing and caution note (Fig. I). FIG. 4 To remove knockouts: Place screwdriver at edge of knockouts, not in the center. DWC. 1761-4 APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions, PRINTED IN USA MKT. 98800001 -REV W PAGE 2 OF 2 MFG. #5400761 - 7/02 (E)POTTER The Symbol of Protection OSYSU-1 Stock No. 1010106 OSYSU-2 Stock No. 1010206 GENERAL INFORMATION The OSYSU is used to monitor the open position of an OS & Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, con- taining two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS & Y valves ranging in size from 2 to 12" (50mm to 300mm). They will mount on some valves as small as 1/2" (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or additional cover OSYSU-1, -2' OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH UL and CSFM Listed, FM Approved, NYMEA Accepted, CE Marked Dimensions: 6.19"L X 2.25"WX 5.88H 15,7cm LX 5,7cm W 14,6cm H Weight: 2 lbs. (0,9 kg.) Enclosure: Cover - Die-Cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: NEMA 4 and NEMA 6P Enclosure (1P67) when used with appropriate watertight conduit fittings. Indoor or Outdoor use (Not for use in hazardous locations. See bulletin no. 5400705 OSYS-U-EX for hazardous locations.) Temperature Range: -40°F to 140°F (-40°C to 60°C) Conduit Entrances: 2 knockouts for 1/2 conduit provided Service Use: Automatic Sprinkler NFPA-1 3 One or two family dwelling NFPA-1 3D Residential occupancy up to four stories NFPA-1 3R National Fire Alarm Code NFPA-72 screws and hex keys are available. See ordering informa- tion on page 4. OPTIONAL COVER TAMPER SWITCH A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTING The OSYSU and its associated protective monitoring sys- tem should be inspected and tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Potter Electric Signal company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8820004 - REV P PAGE 1 OF 4 12/01 (E)POTTER The Symbol of Protection OSYSU-11 -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. I SMALL VALVE INSTALLATION - 1/2" THRU 2 1/2" (12,5mm THRU 63,5mm) SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2" TO 12" OS & Y VALVES. THEY WILL MOUNT ON SOME VALVES AS SMALL AS 1/2 (12,5MM). J-HOOKS MAY BE REQUIRED ON VALVES WITH LIMITED CLEARANCE. CLAMP BAR CARRIAGE BC SLOTTED MOUNTING HOLES MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET BRACKET DWG. #979-3 SMALL VALVE INSTALLATION Remove and discard 'C' washer and roller from the trip rod. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non- threaded portion of the valve stem. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the 1" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. Mark the valve stem at the center of the trip rod. Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark on the valve stem utilizing a 3/16" (4,8mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 1) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate when the trip rod moves out of the groove. Tighten the adjustment screws and all mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 2 OF 4 12/01 (E)POTTER The Symbol of Protection OSYSU-1, -2' OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" (76mm THRU 300mm) SIZES 3" THRU 12" (76mm THRU 300mm) VALVES BRACKET USE CARRIAGE BOLTS. BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. CARRIAGE BOLTS SLOTTED MOUNTING (2 REQUIRED) HOLES. MAY BE USED FOR FINE ADJUSTMENT ROLLER OF SWITCH ON BRACKET. \ GROOVE / YOKE VALVE STEM TRIP ROD DWG. #979-4 L— GLAND LARGE VALVE INSTALLATION With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non- threaded portion of the valve stem. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one 1" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 proce- dure. Mark the valve stem at the center of the trip rod. Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark of the valve stem utilizing a 3/8" (9,5mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU loosely with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 2) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. Tighten the adjustment screws and mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 3 OF 4 12/01 (E)POTTER The Symbol of Protection OSYSU-1, -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. 3 DIMENSIONS FIG. 4 PARTS Rtw ROD II I .CD EDDEDDED I SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL INGO 006 C'0106 0 of OWG. 1923-3 TYPICAL ELECTRICAL CONNECTIONS LOCAL CIRCUIT N.O. INDICATING TO POWER FOR COI-N.C. LEI\ DEVICE INDICATING DEVICE I TO SUPERVISORY CIRCUIT CO'EM. NC END OF OF CONTROL PANEL LINE RESISTOR DWG. #979-1 BREAKING EXCESSIVE ROD LENGTH FIG. 5 NC. flfl_7 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervi- sion of the connection in the event that the wire becomes dislodged from under the terminal. ORDERING INFORMATION MODEL DESCRIPTION STOCK NO. OSYSU-1 Outside Screw & Yoke-Supervisory Switch (Single switch) 1010106 OSYSU-2 Outside Screw & Yoke-Supervisory Switch (Double switch) 1010206 -- Cover Screw 5490344 -- Hex Key for Cover Screws and Installation Adjustments 5250062 -- Optional Cover Tamper Switch Kit 0090131 For pressure reducer type valve installation kits (if required) contact valve manufacturer. Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION OPEN VALVE POSITION CLOSED VALVE POSITION COM. ,J, NO CM.f SW #1 SW #1 ¶.N.C. COM. I NO coM. SW #2 SW #2 DWG. #979-2 PRINTED IN USA MKT. #8820004 - REV P PAGE 4 OF 4 12/01 Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -300 to 150°F (-340 to 660C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. SIZE INCHES (mm) VOLTAGE MODEL NO. STOCK NO. CURRENT TYPICAL dB AT 10 FT. (3m) (2) MINIMUM dB AT 10 FT. (3m) (1) 6(150) 12VDC PBD126 1706012 .12A 85 76 8(200) 12VDC PBD128 1708012 .12A 90 76 10(250) 12VDC PB1D1210 1710012 .12A 92 76 6(150) 24VDC PBD246 1706024 USA 87 76 8 (200) 24V00 PBD248 1708024 06A 91 79 10 (250) 24V0C PBD2410 1710024 .06A 94 79 6(150) 24VAC PBA246 1806024 .17A 91 76 8(200) 24VAC P8A248 1808024 .17A 94 76 10 (250) 24VAC PBA2410 1810024 .17A 94 76 6(150) 120VAC PBA1206 1806120 .05A 92 82 8(200) 120VAC PBA1208 1808120 05A 99 82 10 (250) 120VAC PBA12010 1810120 .05A 99 85 BELLS @PO-ffER PBA-AC & PBD-DC The Symbol of Protection UL Listed, FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10(250mm) Voltages Available: 24VAC 12OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: lndooror outdoor use (See Note 1) -400 to 150°F (400 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powdercoating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-18330www.pottersignal.com PRINTED IN USA MKT. #8850001 - REV 0 PAGE 1 OF 2 MFG. #5400776 - 12/01 (E)P OTTER The Symbol of Protection BELLS PBA-AC & PBD-DC DIMENSIONS INCHES (mm) FIG. I BELLS FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONETHREADED 1/2 CONDUIT ENTRANCE tfl 10" (250) 5 3/4" 0 I (146) (20 5D) 1 5/8 2 I1/16" DWG, fl776-I (41) (68) : 3 3/8" (86) 4 1/4" (108) 3 3/8" 5- (86) (127) DWG. #776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A,C. BELLS RED IN RED (OUT) WHITE (IN) WHITE (OUT) OR END-OF-LINE OR OR FROM CONTROL PANEL TO NEXT BELL FROM CONTROL PANEL CBLIACK RESISTOR PRECEDING BELL PRECEDING BELL D ______________ BlACK (Our) BLACK BLACK (IN) _______________ _ CAUTIO WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: 1, OBSERVE POLARITY TO RING D.C. BELLS, RED WIRES POSITIVE (+) BLACK WIRES NEGATIVE (-) CAION WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING A.C. BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2, END-OF-LINE RESISTOR IS NOT REQUIRED ON A.C. BELLS, DWG. #776-3 INSTALLATION The bell should be mounted a minimum of 8 ft. (2,4m) from the floor or as close to the ceiling as possible. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REV 0 PAGE 2 OF 2 MFG. #5400776 - 12/01 YU31 Contractor's Material and Test Certificate for Aboveground piping PROCEDURE Upon completion of work inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners and contractor. It is understood the owners representatives signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. .r 1J PROPERTY NAME: Ventana Real II C-iDATE: PROPERTY ADDRESS: 2175 Salk Ave., Carlsbad, CA IC ACCEPTED BY APPROVING AUTHORITIES (NAMES): Carlsbad Fire Dept, ADDRESS: PLANS INSTALLATION CONFORMS TO ACCEPTED PLANS ki YES U NO EQUIPMENT USED IS APPROVED El YES []NO IF NO, EXPLAIN DEVIATIONS: HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? El YES 0 NO IF NO, EXPLAIN INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: U YES U NO SYSTEM COMPONENTS INSTRUCTIONS El vs 0 NO CARE AND MAINTENANCE INSTRUCTIONS El YES 0 NO NFPA25 ElYES NO LOCATION SUPPLIES BUILDINGS: OF SYSTEM YEAR OF ORIFICE TEMPERATURE MAKE MODEL MANUFACTURI SIZE QUANTITY RATING Tyco TY3131 2009 1/2 755 175 Tyco TY3531 2009 1/2 69 155 SPRINKLERS Tyco TY3231 2009 1/2 30 155 Tyco 1Y3231 2009 1/2 2 155 Tyco TY3488 2009 1/2 24 175 PIPE AND Type of Pipe: Dyna-Flow, Dyna thread FITTINGS Type of Fitting: Grooved, Ci/Di Threaded 1Tik 1 ThIg T UiiftJ ALARM ALARM DEVICE THROUGH TEST CONNECTION VALVE OR FLOW TYPE MAKE MODEL MIN SEC Flow Switch Potter VSF INDICATOR DRY VALVE Q.O.D. MODEL SERIAL NO. MAKE MODEL SEJAL1O. TIME TO TRIP TIME ER ALARM TflUOflT[ "1AIçjj Iff TfflDOUT Jt111ED DRY PIPE OPERATING TEST _____ CONNECTION PRESS PRESSURE AIR PRESLlR' TEST OUTLET PROPERLY _____AiLb _____ MIN SEC PSI -.,fSI PST MIN SEC YES NO Without Q.O.D. With IF NO, EXPLAIN TION 0 PNEUMATIC 0 ELECTRIC 0 HYDRAULIC PIPING SUPERVISED —.4_1YES U NO - J DETECTING MEDIA SUPERVISED—jJYES LI NO DOES VALVE OPERATE FROM THE NALJIP AND/OR REMOTE CONTROL STIJONS fl YES fl No DELUGE AND IS THERE AN ACCESSIBLE FACILITY IN EACH CIR IR TESTING IF NO, EXPLAIN PREACTION VALVES DYES DOESJACWCICUIT OPERATE DOES EACH CIRCUI MAXIMUM TIME TO MAKE MODEL JOR VISION LOSS ALARM? OPERATE VALVE RELEASE? RATE RELEASE YES - NO YES NO MIN. SEC. PRESSURE [CT5N- -MAKE.& SETTING STATIC PRESSURE RESIDUAL PRESS E REDUCING & FLOOR MODEL - -_ OWING) VALVE TEST —tNtEflII5 J OU SI OUTLET (PSI) FLOW (GPM) HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 pai (3.4 bars) above TEST static pressure in excess of 150 psi (10.2 bars) for two hours. Differential dry-pipe valve Clappers shall be left open during DESCRIPTION test to prevent damage. All abovegroung piping leakage shall be stopped. PNEUMATIC: Establish 40 psi (2.7 bars) air pressure and measure drop Which shall not exceed 1-1/2 psi (.01 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR _ HRS IF NO, STATE REASON DRY PIPING PNEUMATICALLY TESTED DYES El NO EQUIPMENT OPERATES PROPERLY EYES 0 NO N/A DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS TEST OR STOPPING LEAKS? El YES 0 NO DRAIN READING OF GAGE LOCATED NEAR WATER. RESIDUAL PRESSURE WITH VALVE IN TEST TEST I SUPPLY TEST CONNECTION: PSI CONNECTION OPEN WIDE PSI UNDERGROUND MAINS AND LEAD IN CONECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MAKE TO SPRINKLER PIPING. VERIFIED BY COPY OF THE U FORM NO. 85B El YES 0 NO OTHER EXPLAIN FLUSHED BY INSTALLER OF UNDER- GROUND SPRINKLER PIPING El YES 0 NO F POWDER-DRIVEN FASTENERS ARE USED IN CONCRETE, HAS REP- RESENTATIVE SAMPLE TESTING BEEN SATISFACTORILY COMPLETED? El YES 0 NO IF NO, EXPLAIN BLANK TESTING NUMBER USED LOCATIONS NUMBER REMOVED GASKETS WELDED PIPING U YES U NO IF YES DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR-37 El YES 0 NO DO YOU CERITIFY THAT THE WELDING WAS PREFORMED BY WELDERS QUALIFIED IN WELDING COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D10.9, LEVEL AR-3? El YES 0 NO DO YOU CERITIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO ENSURE THAT ALL DISCS ARE RETRIEVED. THAT OPENINGS IN PIPING ARE SMOOTH. THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? El YES 0 NO CUTOUTS DO YOU CERITIFY THE YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL (DISCS) CUTOUTS (DISCS) ARE RETRIEVED? El YES FIND HYDRAULIC NAME PLATE PROVIDED IF NO, EXPLAIN DATA NAMEPLATE El YES []NO DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: REMARKS NAME Of- SIKtNKLLF't CON lKAC101 MILLENNIUM FIRE PROTECTION CORPORATION TESTS WITNESSED BY SIGNATURES FOR PROPERTY OWNER (SIGNED) TITLE DAT \ -.- I FOR SPRIN R CONTR TITLE WE ADDITIONAL EXPLAN AND NOTES " /