Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
5475 CAR COUNTRY DR; ; AS140105; Permit
City of Carlsbad Sprinkler Permit Permit No: AS140105 5475 CAR Job Address: Status: ISSUED COUNTRY DR Permit Type: SPRINK Applied 4/23/2014 Parcel No: 2110800900 Approved: 4/30/2014 Lot #: 0 Reference No.: Issued: 4/30/2014 PC #: Inspector: Project Title: HOEHN SPRINTER SVC BLDG INSTALL NEW COMMERCIAL FIRE SPRINKLER SYSTEM FOR COMMERCIAL AUTOMOTIVE SERVICE FACILITY. DESIGN DENSITY IS .20/1500 FOR ORD. HAZ. GRP II Applicant: TATE FIRE PROTECTION SERVICES, INC. STEC 13691 DANIELSON ST POWAY, CA Owner: HOEHN GROUP L L C P 0 BOX 789 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 1,445 0 1,445 0 - - - Fire Protection by Computer Design TATE FIRE PROTECTION SERVICES, 13771 DANIELSON ST SUITE G POWAY, CA 92064 858 486 0900 Job Name HOEHN SPRINTER Building : S14-146 Location 5475 Car Country Dr. Carlsbad, CA 92008 System : System #1 Contract : S14-146 Data File : HOEHN SPRINTER CALCS FINAL.WXF A5140105 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 S --TATE FIRE PROTECTION SERVICES, HOEHN SPRINTER HYDRAULIC CALCULATIONS for Project name: Hoehn Sprinter Location: 5475 Car Country Dr. Carlsbad, CA 92008 Drawing no: S14-146 Date: 4.21.14 Design Remote area number: System #1 Remote area location: Occupancy classification: Ord Haz Gp II Density: .20 - Gpm/SqFt Area of application: 1567.862 - SqFt Coverage per sprinkler: 130 - Sq Ft Type of sprinklers calculated: Tyco Iy31 3, 5.6 k- factor, 1/2" No. of sprinklers calculated: 14 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 648.258 -GPM Type of system: Wet Sprinkler System Volume of dry or preaction system: N/A - Gal Water supply information Date: 3/11/14 Location: 5475 Car Country Dr. Carlsbad, CA 92008 Source: Hydrant 28A3H5 (back lot of Hoehn Mercedes) Name of contractor: Tate Fire Protection Serv. Inc. Address: 13771 Danielson St. Suite G, Poway, CA 92008 Phone number: 858.486.0900 Name of designer: Christian McGregor Authority having jurisdiction: City of Carlsbad Notes: (Include peaking information or gridded systems here.) Page 1 Date 4/17/14 @ 68.402 - Psi S Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TATE FIRE•TECTION SERVICES, HOEHN SPRINTER Page • Date 4/17/14 City Water Supply: Demand: Cl - Static Pressure : 72 Dl - Elevation : 11.585 C2 - Residual Pressure: 61 D2 - System Flow : 398.258 C2 - Residual Flow : 1186 D2 - System Pressure : 58.967 Hose ( Demand ) : 250 D3 - System Demand : 648.258 Safety Margin : 9.435 150 140 130 p120 R° E10° S90 S80 u 70 R 60 E 50 - ercent tinder - 40 30 20 10 --Dl— I 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N "1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TATE FIRE•TECTION SERVICES, Page 0 HOEHN SPRINTER Date 4/17/14 Fitting Legend Abbrev. Name 1/2 3/4 1 1% 11/2 2 21/2 3 3',4 4 5 6 8 10 12 14 16 18 20 24 Avk Alarm Viking Ji 10 13 20 23 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zii Wilkins 475 Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD - TATE FIRE PROTECTION SERVICES, Page 4 HOEHN SPRINTER Date 4/17/14 Node Elevation K-Fact Pt Pn Flow Density Area Press Actual Actual Req. 1 20.5 5.6 20.29 na 25.23 0.2 126 7.0 2 20.75 5.6 20.25 na 25.2 0.2 126 7.0 3A 21.0 5.6 19.11 na 24.48 0.2 47 7.0 3 21.0 20.33 na 4A 20.5 5.6 20.9 na 25.6 0.2 123.3 7.0 4 20.5 5.6 19.65 na 24.82 0.2 118.62 7.0 5 20.5 5.6 21.99 na 26.26 0.2 123.3 7.0 6 20.5 5.6 23.85 na 27.35 0.2 123.3 7.0 7 20.5 5.6 26.38 na 28.76 0.2 123.3 7.0 8 20.5 30.99 na 9 21.0 5.6 23.36 na 27.07 0.2 98.64 7.0 10 21.0 5.6 23.8 na 27.32 0.2 123.3 7.0 11 21.0 25.77 na hA 21.0 5.6 27.75 na 29.5 0.2 130 7.0 12 20.5 5.6 19.9 na 24.98 0.2 98.64 7.0 13 20.5 5.6 21.26 na 25.82 0.2 123.3 7.0 14 20.5 5.6 23.0 na 26.86 0.2 123.3 7.0 15 20.5 5.6 26.82 na 29.0 0.2 123.3 7.0 16 20.5 35.01 na 17 20.5 35.05 na 18 20.5 35.16 na TOR 20.5 37.68 na BOR -6.0 50.49 na BF1 2.5 47.18 na BF2 -6.0 58.54 na POC -6.0 58.97 na 250.0 S The maximum velocity is 19.17 and it occurs in the pipe between nodes 7 and 8 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007. TATE FIRE PROTECTION SERVICES, Page 5 HOEHN SPRINTER Date 4/17/14 Hyd. Qa Dia. Fitting Pipe Pt Pt 4kf. 'C' or Ftng's Pe Pv Notes int Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 25.23 2.104 0.0 10.000 20.291 K Factor = 5.60 to 120.0 0.0 0.0 -0.108 2 25.23 0.0067 0.0 10.000 0.067 Vel = 2.33 2 25.20 2.104 0.0 7.833 20.250 K Factor = 5.60 to 120.0 0.0 0.0 -0.108 3 50.43 0.0243 0.0 7.833 0.190 Vel = 4.65 0.0 50.43 20.332 KFactor= 11.18 3A 24.48 1.08 IT 5.762 1.667 19.112 K Factor= 5.60 to 120.0 0.0 5.762 0.0 3 24:48 0.1642 0.0 7.429 1.220 Vel = 8.57 3 50.43 2.104 0.0 7.000 20.332 to 120.0 0.0 0.0 0.217 4A 74.91 0.0504 0.0 7.000 0.353 Vel = 6.91 4A 50.42 2.104 0.0 8.333 20.902 K Factor = 5.60 to 120.0 0.0 0.0 0.0 5 125.33 0.1309 0.0 8.333 1.091 Vel = 11.57 0.0 125.33 21.993 K Factor= 26.72 4 24.82 1.08 1T 5.762 1.667 19.651 K Factor= 5.60 . 120.0 0.0 5.762 0.0 24.82 0.1684 0.0 7.429 1.251 Vel = 8.69 0.0 24.82 20.902 K Factor = 5.43 5 151.60 2.104 0.0 10.000 21.993 K Factor= 5.60 to 120.0 0.0 0.0 0.0 6 151.6 0.1860 0.0 10.000 1.860 Vel = 13.99 6 27.35 2.104 0.0 10.000 23.853 K Factor= 5.60 to 120.0 0.0 0.0 0.0 7 178.95 0.2529 0.0 10.000 2.529 Vel = 16.51 7 28.76 2.104 0.0 13.830 26.382 K Factor= 5.60 to 120.0 0.0 0.0 0.0 8 207.71 0.3333 0.0 13.830 4.609 Vel = 19.17 8 0.0 2.635 1T 16.474 21.000 30.991 to 120.0 0.0 16.474 0.0 18 207.71 0.1114 0.0 37.474 4.173 Vel = 12.22 0.0 207.71 35.164 K Factor= 35.03 9 27.07 1.408 0.0 8.000 23.363 K Factor = 5.60 to 120.0 0.0 0.0 0.0 10 27.07 0.0544 0.0 8.000 0.435 Vel = 5.58 10 27.32 1.408 0.0 10.000 23.798 K Factor= 5.60 to 120.0 0.0 0.0 0.0 11 54.39 0.1975 0.0 10.000 1.975 Vel = 11.21 11 0.0 1.408 0.0 10.000 25.773 120.0 0.0 0.0 0.0 A 54.39 0.1975 0.0 10.000 1.975 Vel = 11.21 11A 29.50 1.639 IT 8.727 25.000 27.748 K Factor = 5.60 to 120.0 0.0 8.727 0.217 17 83.89 0.2101 0.0 33.727 7.087 Vel = 12.76 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TATE FIRE PROTECTION SERVICES, Page 6 HOEHN SPRINTER Date 4/17/14 Hyd. pf. Qa Dia. "C" Fitting or Pipe Ftng's Pt Pt Pe Pv ******* Notes int Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 83.89 35.052 K Factor= 14.17 12 24.98 1.08 0.0 8.000 19.899 K Factor = 5.60 to 120.0 0.0 0.0 0.0 13 24.98 0.1704 0.0 8.000 1.363 Vel = 8.75 13 25.82 1.408 0.0 10.000 21.262 K Factor = 5.60 to 120.0 0.0 0.0 0.0 14 50.8 0.1741 0.0 10.000 1.741 Vel = 10.47 14 26.86 1.408 0.0 10.000 23.003 K Factor = 5.60 to 120.0 0.0 0.0 0.0 15 77.66 0.3818 0.0 10.000 3.818 Vel = 16.00 15 29.00 1.639 0.0 25.000 26.821 K Factor = 5.60 to 120.0 0.0 0.0 0.0 16 106.66 0.3277 0.0 25.000 8.193 Vel = 16.22 16 0.0 4.26 0.0 12.250 35.014 to 120.0 0.0 0.0 0.0 17 106.66 0.0031 0.0 12.250 0.038 Vel = 2.40 17 83.89 4.26 0.0 12.250 35.052 to 120.0 0.0 0.0 0.0 18 190.55 0.0091 0.0 12.250 0.112 Vel = 4.29 . 207.71 4.26 3E 39.501 30.833 35.164 120.0 0.0 39.501 0.0 TOR 398.26 0.0358 0.0 70.334 2.517 Vel = 8.96 TOR 0.0 4.26 lAvk 17.117 20.000 37.681 to 120.0 0.0 17.117 11.477 BOR 398.26 0.0358 0.0 37.117 1.328 Vel = 8.96 BOR 0.0 6.3 3E 76.372 29.000 50.486 to 150.0 0.0 76.372 -3.681 BF1 398.26 0.0035 0.0 105.372 0.371 Vel = 4.10 BF1 0.0 6.3 lZii 0.0 4.000 47.176 to 150.0 0.0 0.0 11.352 * * Fixed Loss = 7.671 BF2 398.26 0.0038 0.0 4.000 0.015 Vel = 4.10 BF2 0.0 6.3 3E 76.372 44.167 58.543 to 150.0 0.0 76.372 0.0 POC 398.26 0.0035 0.0 120.539 0.424 Vel = 4.10 250.00 - Qa = 250.00 648.26 58.967 K Factor= 84.42 S Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I PROTECTION SERVICES INC. C-16 License #926322 13771 Danielson Street, Suite G - Poway, CA 92064 Phone (858) 486-0900 - Fax (858) 486-0950 DATE: 04-21-2014 PROJECT: HOEHN SPRINTER 5475 CAR COUNTRY DR. CARLSBAD, CA 92008 GENERAL CONTRACTOR: WHITE CONSTRUCTION 2540 GATEWAY RD. CARLSBAD, CA 92008 r-] FIRE SPRINKLER MODIFICATION MATERIAL SUBMITTAL AS140105 Schedule-1O/Schedule-40® Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule- 10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (11/"- 8") pipe and Sch-40 (1"- 2'/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Schedule-i 0/Schedule-40 product can be "hot-dip" galvanized to meet FM requirements for dry systems in accordance with the zinc coating specifications of ASTM A-123. Our advanced formula mill coating of- fers a clean, durable surface. It is also paint-ready for custom color applications without special preparation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial For- mula, "ABF". In scientific laboratory test, ABS proved to have superior resis- tance to microbial colonization of pipe walls, thereby delaying or possibly pre- venting the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Meets "Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Sch-40 Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pc WI/Lift (21) WI/Lift (24) WI/Lift (25) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs, Kg 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 11/4 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 11/2" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2' 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21/2 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 Sch-10 Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pcs/ WI/Lift (21') WI/Lift (24) WI/Lift (25) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1' 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4" 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 2.7 3.75 61 1,052 1,208 1,252 11/2" 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3' 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4.260 5.610 11.78 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8' 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Schedule- 10/Schedule-40 pipe are in compliance with the following: ASTM A-135, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets (& Ii Hydrostatic Pressure Listed Approved Listed Side Wall Rupture Vibration Test tqco/Flow control allied 16100 S. Lathrop• Harvey, IL 60426 11350 Norcom Rd. • Philadelphia, PA 19154 Customer Service: (800) 882-5543 TUBE & CONDUIT 2525 N. 27 Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5 -3 1.104 1.13 1.61 91 2,333 2,667 2,570 25 28.0 1.8 2.40 91 1,060 1,211 1,228 11/4' 1.452 1.46 2.25 61 2,019 2,307 2,226 32 36.9 2.3 3.35 61 917 1,048 1,058 11/2' 1.687 1.76 2.84 61 2,409 2,753 2,684 40 42.8 2.8 4.23 61 1,094 1,250 1,294 2.154 2.35 4.06 37 1,959 2,239 2,173 50 54.7 3.7 6.04 37 890 1,017 1,041 21/2 * 2.581 4.08 6.34 30 2,571 2,939 3,060 65 65.5 6.05 9.45 30 1,168 1,335 1,390 3* 3.200 5.01 8.49 19 1,999 2,285 2,380 80 81.2 7.43 12.7 19 908 1,038 1,081 * XL only XL:/BLTO Galvanized and Black Lightwall Threadable Pipe The original "Galvanized" and "Black" Threadable Lightwall pipes with exceptional hydraulics and economy. XL®/BLT®'s proven hydraulic It!1-1 [']i!- advantage and lighter weight adds value to any system. When you need a proven NPS Nominal I.D. WI. WI. (H20 Filled) Pc WI/Lift (21) WI/Lift (24) WI/Lift (25) sprinkler pipe, specify XL/BLT. In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg XL/BLT pipe are an exceptionally strong steel sprinkler pipe of the class generally known as "lightwall threadable pipe". Its wall thickness is less than that of Sch-40 or Sch-10, but the cold forming process undergone in manufacturing gives XL/BLT pipe mechanical strength characteristics equivalent to those required for Sch-40 It is designed for use in wet, dry, preaction and deluge systems. XL/BLT can be joined with threaded couplings (when in accordance with ANSI B 1.20.1), roll grooved or plain-end couplings, or welded joints. XL! BLT products have metallurgical properties which provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No special process or equipment are needed for fabrication and installation. XL is manufactured with galvanized coating. BLT is black lacquer coated. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. XL/BLT pipe is manufactured to meet ASTM A-135, Grade A for fire sprinkler applications up to 300 psi working pressure. Listed Approved Listed It is UL listed for wet, dry, preaction and deluge systems, and FM approved for wet sprinkler systems. XL/BLT is ULC listed for wet, dry and preaction systems. All threaded and welded fittings are approved in accordance with NFPA 13. FM requires 12' maximum hanger spacing for XL/BLT. C-Factors for XL! BLT are 120 for wet systems, and C=100 for dry systems. Refer to Hazen- Williams charts for accurate flow comparisons. XL/BLT pipe offers the maximum hydraulic advantage of any available threadable sprinkler pipe. Its inside diameter is up to 5% larger than Sch40. The use of XL/BLT in conjunction with Dyna-Flow pipe, can dramatically improve the flow characteristics, thereby increasing the potential for "downsizing" system components. The clean surface quality of XL/BLT is readily paintable. The lighter weight of XL/BLT is a distinct advantage for retro-fit installations and can also reduce labor costs. Q " 16100 S. Lathrop• Harvey, IL 60426 r allied tLICO/F/ow Control 11350 Norcom Rd. Philadelphia, PA 19154 TUBE & CONDUIT 07 th Ave. • Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 S4 -3 Stamp Here American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered Iightwall and standard wall family of products al- though they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna- Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is manufac- tured with Black lacquer coating. @Ue L <~> 9 Listed Approved Listed Submittal Data Sheet XL/BLT 0 Galvanized and Black Lightwall Threadable Pipe XL!BLT's proven hydraulic advantage and lighter weight adds value to any system. When you need a proven sprinkler pipe, specify XL/BLT. Product Description XL/BLT pipe are exceptionally strong steel sprinkler pipe of the class generally known as "lightwall threadable pipe". Its wall thickness is less than that of Sch-40 or Sch-10, but the cold forming process undergone in manufacturing gives XL/BLT pipe mechanical strength characteristics equivalent to those required for Sch-40. It is designed for use in wet, dry, pre-action and deluge systems. XL/BLT can be joined with threaded couplings (when in accordance with ANSI 131.20. 1), roll grooved or plain-end couplings, or welded joints. Other Benefits The clean surface quality of XLIBLT is readily paintable. The lighter weight of XL/BLT is a distinct advantage for retro-fit installations and can also reduce labor costs. Coatings & Fabrication XL! BLT products have metallurgical properties which provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. No special process or equipment are needed for fabrication and installation. XL is manufactured with galvanized coating. BLT is black lacquer coated. The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Superior Hydraulics XL!BLT pipe offers the maximum hydraulic advantage of any available threadable sprinkler pipe. Its inside diameter is up to 5% larger than Sch-40. The use of XLIBLT in conjunction with Dyna-Flow pipe, can dramatically improve the flow characteristics, thereby increasing the potential for "downsizing" system components. Specifications & Approvals XL!BLT pipe is manufactured to meet ASTM A135, Grade A for fire sprinkler applications up to 300 psi working pressure. It is UL listed for wet, dry, pre-action and deluge systems, and FM approved for wet sprinkler • systems. XL/BLT is ULC listed for wet, dry and pre-action systems. All threaded and welded fittings are approved in accordance with NFPA 13. FM requires 12' maximum hanger spacing for XL!BLT. C-Factors for XL!BLT are 120 for wet systems, and C=100 for dry systems. Refer to Hazen-Williams charts for accurate flow comparisons. Specifications NPS Nominal I.D. WI. WI. (H20 Filled) Pcs/ Wt/Lift (21) Wt/lift (24) WI1Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.104 1.13 1.61 91 2,333 2,667 2,570 25 28.0 1.8 2.40 91 1,060 1,211 1,228 11/4' 1.452 1.46 2.25 61 2,019 2,307 2,226 32 36.9 2.3 3.35 61 917 1,048 1,058 11/2" 1.687 1.76 2.84 61 2,409 2,753 2,684 40 42.8 2.8 4.23 61 1,094 1,250 1,294 2' 2.154 2.35 4.06 37 1,959 2,239 2,173 50 54.7 3.7 6.04 37 890 1,017 1,041 21/2 * 2.581 4.08 6.34 30 2,571 2,939 3,060 65 65.5 6.05 9.45 30 1,168 1,335 1,390 3* 3.200 5.01 8.49 19 1,999 2,285 2,380 80 81.2 7.43 12.7 19 908 1,038 1,081 * XL only Hayes-Palo Alto Middle School J. G. Tate Fire Protection 2.1.02 Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: I nratinnQ S4-4 Comments: Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes, the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Exaggerated for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel. Optional: Hot dipped galvanized and others. Gasket: (specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/-i-82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "F' nitrite Nitrile (Orange color code). Temperature range —20°F to +80°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over +140°F/+60°C and water over +150°F/-t-66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. NOTE: Additional gasket styles are available. Contact Victaulic for de-.ails. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_K \4taulac 06.051 - CARBON STEEL PIPE - GROOVED COUPLINGS 06.05 Flexible Coupling STYLE 75 DIMENSIONS 1 1.315 500 680 0-0.06 2 - 43 2 -3/8x2 0.57 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 48 61 108 45 0.6 1 1/4 1.660 500 1080 0-0.06 T - rn 2 -¼x2 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 38 68 117 45 0.6 1½ 1.900 500 1.420 0-0.06 - 2-3/8x2 0.40 2.91 4.82 1.77 1.5 40 48,3 3450 6320 0-1.6 33 74 122 45 0.6 2 2.375 500 2.215 0-0.06 1 -31' 0.32 2-¼x2 3.43 522 1.88 1.7 50 60.3 3450 9860 0-1.6 26 87 133 48 0.8 2½ 2.875 500 3.245 0-0.06 1-15' 026 2 2 3/8 3.88 5.68 1.88 1.9 -x 65 73.0 3450 14440 0-1.6 22 98 144 48 0.9 76.1 mm 3.000 500 3.535 0-0.06 1 • 2-3/8x2 12' 0.26 4.00 5.90 1.88 1.9 76.1 3450 15730 0-1.6 22 102 150 48 0.9 3 3.500 500 4.800 0-0.06 - 2' 0.22 2-½ x234 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 18 114 178 48 13 3½ 4.000 500 6.300 0-0.06 0 54 0.19 2 -½ x21/4 5.00 7.50 1,88 2.9 90 101.6 3450 28035 0-1.6 16 127 191 48 1.3 4 4.500 500 7.950 0-0.13 1• - 35 2-½x234 0.34 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 28 147 204 54 1.9 108.0 mm 4.250 450 6.380 0-0.13 1• - 2-12 x 70.0 41' 0.35 5.55 7.79 2.13 3.7 108.0 3100 28395 0-3.2 29 141 198 54 1.7 4½ - 2-%x3¼ 5.000 450 8.820 0-0.13 ]• 26' 0.25 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 21 156 240 54 2.5 . 5 5.563 450 10.935 0-0.13 1 - 2-%x3¼ 18' 0.27 6.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 23 175 256 54 2.6 133.0 mm 5.250 450 9.735 0-0.13 -21' 0.28 6.55 9.37 2.13 6.0 2- 16x 82.5 133.0 3100 43325 0-3.2 24 166 238 54 2.7 139.7 mm 5.500 450 10 2-5/8x3Y4 .665 0-0.13 1- 18' 0.28 6.80 9.59 2.13 63 139.7 3100 47460 0-3.2 24 173 244 54 2.9 152.4 mm 6.000 450 12.735 0-0.13 1 2-½x31/4 -12' 0.21 7.38 10.48 1.88 6.2 152.4 3100 56670 0-3.2 18 187 266 48 2.8 6 6.625 450 15.525 0-0.13 , 0.23 2 - tAx 31/4 8.00 11.07 2.13 7.0 150 168.3 3100 69085 0-3.2 18 203 281 54 3.2 Continued on page 3. 1 t @ Refer to notes on page 3. .• . .. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 06.052 4tauiicr REV K CARBON STEEL PIPE - GROOVED COUPLINGS Flexible Coupling STYLE 75 06.05 .. DIMENSIONS 159.0mm 6 . 250 450 13.800 0-0.13 , 1 - 0.24 2-16 x82.5 7.63 10.49 2.13 6.8 159.0 3100 61405 0-3.2 20 194 266 54 3.1 203.2 mm 8 . 000 450 22.635 0-0.13 0. - 54' 0.16 2-~ ¼ x4 9.72 13.33 2.31 12.6 203.2 3100 100725 0-3.2 13 247 339 58 5.7 8 8.625 450 26.280 0-0.13 o - 50' 0.18 10.34 13.97 2.32 12.4 200 219.1 3100 116945 0-3.2 14 2-Y4x41/4 263 355 59 5.6 254.0mm 10.000 350 27.500 0-0.13 o. - 43• 0.15 2-x5½ ¼ 12.16 15.81 2.53 20.8 254.0 2400 122375 0-3.2 11 309 402 64 9,4 304.8mm 12.000 350 39.500 0-0.13 . -36, 0 0.13 I 2 - x 5½ 14.16 17.69 2.53 23.6 304.8 2400 175775 0-3.2 360 449 64 10.7 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or Cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 1/4 -3 1/2/20 -90 mm; 25% for 4/100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. www.victaulic.com vICTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_K 4tauIcr 06.05_3 Flexible Coupling WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. For complete contact information, visit www.victaulic.com 06.05 1470 REV K UPDATED 3/2009 iCt9UIiC VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 06.05 n Malleable Iron Class 150 (standard) INVI L - INTERNATIONAL, NC. 900 Elbow Figure 1101 Size (NPS) A (in) Weight (Ibs) black galv. 1/6 11/16 .06 .07 1/4 13/16 .11 .12 3/ 15/16 .17 .17 1/2 11/6 .26 .27 1/ .38 .43 1 1'/2 .63 .65 1 1/4 1/4 .96 94 11/2 115/16 1.30 1.34 2 21/4 2.06 2.01 21/2 211/16 3.54 3.64 3 31/16 5.20 5.35 31/3 3/16 7.10 7.19 4 313/16 8.95 9.37 5 41/2 13.90 14.50 6 51/8 23.00 23.50 ALL ELBOWS & TEES Y AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.anvilinti.com (12/10/01) Malleable Iron Class 150 (standard) (fr)iwI ) INTERNATIONAL, INC. 450 Elbow Figure 1102 Size (NPS) C (in) Weight (Ibs) black galv. I Ij_ 1/8 11/16 .06 .08 1/4 3/4 % 13/86 .16 .18 8/2 /8 .21 .24 3/4 1 .37 .39 1 11/8 .54 .57 11/8 1/16 .86 .87 11/2 1/16 1.13 1.17 2 111/16 1.71 1.85 21/ 115/16 2.78 2.90 3 2/1 4.48 4.58 4 2/8 7.20 7.35 5 31/ 11.46 11.75 6 3/16 1 17.24 =K1 * P.O. A. ALL ELBOWS & TEES W AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.anvilinti.com (12/10/01) C Malleable Iron Fittings (Class 150 standard) AP"IL INTERNATIONAL, INC. Couplings Figure 1125 Size (NPS) M (in) Weight (Ibs) black galv. T M 1/4 1/8 1 .07 .08 3/ 1/8 1118 .11 .13 1/4 .11 .12 1/2 1/8 11/4 .14 .15 Vi .15 .16 ½ .16 .18 1/8 .24 .25 ½ .22 .23 .25 .26 ½ .26 .28 1 1/4 lhVI6 .35 .37 .35 .38 1/2 .39 .41 ½ .42 .44 1½ 1/2 21/16 .60 .63 ½ .64 .65 .68 .70 1/2 2'! 16 .77 .80 1'/ 2 ½ .88 .90 1 .90 .91 1'/4 .90 .93 2 1/2 213/16 1.15 1.20 ½ 1.34 1.34 1 1.40 1.40 11/4 1.53 1.53 11/2 1.55 1.57 21/2 i 31/4 2.12 2.20 11/4 - 2.09 2.14 11/2 2.09 2.11 2 2.50 1 2.56 3 1 311/16 3.16 3.24 1½ 3.22 3.05 11/2 3.30 3.47 2 3.23 3.38 21/2 3.31 3.40 31/2 2 4 4.32* 4,40* 21,/2 4.72* 4.80* 3 4.99 5.15 4 11/2 43/, 4.90 5.00 2 5.10 5.00 21/2 5,93 5.95 3 6.55 6.62 31/2 6.30 6.45 5 4 4/,6 9.57 9.20 6 4 4's/16 10,30 10.70 *POA www.anviIintl.com (12/10/01) Malleable Iron Fittings (Class 150 standard) (ew) iW i INTERNATIONAL. INC. Malleable Iron Threaded Pipe With Unions Pressure -Temperature Ratings Temp (°F) Pressure, (psig) Class 150 Class 250 Class 300 -20° to 150° 300 500 600 200° 265 455 550 250° 225 405 505 300° 185 360 460 350° 150 315 415 400° 110 270 370 450° 75 225 325 500° -- 180 280 550° -- 130 230 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F Anvil Class 150 (Standard Weight) Malleable Iron Fittings conform to ASME 816.3 and Unions conform to ASME B16.39. Anvil standard weight banded pattern fittings in this catalog, sizes Y8 NPS to 6 NPS inclusive, are included in the "List of Inspected Malleable Iron Threaded Fittings Pressure -Temperature Ratings Temp '°P Pressure, (psig) Class Class 300 150 Sizes /4 - 111 1/4" Sizes 11/4"-2" Sizes 21/2"-3" -20° to 150° 300 2,000 1,500 1,000 200° 265 1,785 1,350 910 250° 225 1,575 1,200 825 300° 185 1,360 1,050 735 350° 150 1,150 900 650 400° -- 935 750 560 450° -- 225 600 475 500° -- 510 450 385 550° -- 300 300 300 Fire Protection Equipment and Materials" issued by the Underwrit- ers' Laboratories, Inc. ALL ELBOWS & TEES Y AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.anvilint;i.com (12/10/01) n Malleable Iron Class 150 (standard) INVI L INTERNATIONAL. INC. Straight Tee Figure 1105 Size (NPS) A (in) Weight (Ibs) black galv. ' E A-. l ------ A 1/8 11/16 .09 .10 1/4 13/16 .15 .16 % 15/16 .23 .24 1/3 11/8 .36 37 1/ .56 .58 1 11/2 .90 .92 11/4 1/4 1 1.31 1.35 11/2 115/16 1.73 1.79 2 21/4 2.52 2.80 21/2 211/16 4.90 5.02 3 31/ 7.12 7.25 31/3 3/16 9.00° 9.40* 4 313/16 11.31 12.30 5 41/2 19.42 19.51 6 51/8 25.50 29.9 *POA Malleable Iron Threaded Pipe With Unions Pressure -Temperature Ratings Temp (°F) Pressure, (psig) Class 150 Class 250 Class 300 -20° to 150° 300 500 600 200° 265 455 550 250° 225 405 505 300° 185 360 460 350° 150 315 415 400° 110 270 370 450° 75 225 325 500° -- 180 280 550° -- 130 230 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F Malleable Iron Threaded Fittings Pressure -Tern erature Ratings Temp '°F' Pressure, (psig) Class Class 300 150 Sizes 1/411 - " Sizes 11/4"-2" Sizes 21/2".3" -20° to 150° 300 2,000 1,500 1,000 200° 265 1,735 1,350 910 250° 225 1,55 1,200 825 300° 185 1.360 1,050 735 350° 150 1.150 900 650 400° -- 935 750 560 450° -- 22:5 600 475 500° -- 51') 450 385 550° -- 300 300 300 Anvil Class 150 (Standard Weight) Malleable Iron Fittings conform to ASME B 16.3 and Unions conform to ASME B16.39. Anvil standard weight banded pattern fittings in this catalog, sizes 1/8 NPS to 6 NPS inclusive, are included in the "List of Inspected Fire Protection Equipment and Materials" issued by the Underwrit- ers' Laboratories, Inc. ALL ELBOWS & TEES /6' AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.anvJlintl.com (12/10/01) Malleable Iron Class 150 (standard) ANVIL INTERNATIONAL, INC. Reducing Tee Figure 1105R Size (NPS) x (in) v (in) z (in) Wt. (Ibs) black galv. 1/5 1/5 1/4 3/4 3/4 3/4 .12 .14 /4 1 I/ 3/4 3/4 3/4 .13 .14 %A6 1 A6%.190 /a 1/4 1/4 V5 13/16 15/16 .19 .20 3I is/is 15/16 15/16 .21 .22 1/2 1 ½ 1 11/8 .29 .29 1/4 7/ 7/ 15/16 .21 .22 /s ---- 1/4 2/2 11/8 11/,6 11/8 .30 .31 3/ 3/ 1 1/16 1 1 1/16 .28 .29 /21 /2 1/4 1 1 1 .27 .29 %1½661½6.30.32 11/4 1½ 13/,6 A3 AS 1 1/s 1/s 11/4 .55 .57 1/4 3/4 1/is li/s 1/16 .45 .46 /s 11/8 15/15 11/8 .36* - /2 1/ 13/16 11/8 11/4 .43 ----- .47 3/4 - 1/4 1 '/16 11/16 11/8 38 AU 3/ 11/8 11/8 11/8 .42 .46* 1/2 13/is 11/4 .46 .49 1 11/16 1%s 1/ .62 .66 11/4 1/8 1/s 1/16 .90 .93 1/4 1 11/2 1/16 1½ .69 .71 1/2 1/2 11/4 11/8 1 3/ 55 55 3/4 1 3/ 1½ li/16 .56 .62 1 11/2 1/s 11/2 .76 .73 3/4 1/2 11/4 1/s 13/s .59 .62 3/4 1/s 1/is 1V16 .73 .75 1 11/2 lYis 11/2 .78 .81 1 1/ 1 1/5 11/8 11/4 .55 .55 3/ 1 /16 1 /16 1 11/4 .60 .63 1/2 1114 11/4 1 /8 .70 .74 3/4 1 3/ 1 3/ 17/16 .82 .84 11/4 111/16 11 '/16 1/16 .92 .97 11/2 113/is 113/is 1/s 1.19 1.24 2 2 2 1/4 1.63 1.63 Size (NPS) X (in) y (in) z (in) Wt. (Ibs) black galv. 1/2 1 19/16 13/s 111/15 .87 .94 1½ 1/4 15/16 1/4 1.04 1.07 3/4 3/4 1/s .86 .86 1 1/i# 17/16 15/i111/is .96 .88 1Y4 1/4 1/ 1.09 1.10 11/4 1 1/2 1/ 11/4 1/16 .76 .79 'A 1/16 1% 1/s .87 .92 1 19/16 11/2 111/16 1.11 1.13 1½ 1/4 111/16 1/4 1.13 1.19 1 1/4 3/ 11/4 11/4 1/16 .86 .89 1/2 13/8 1/s 19/16 .98 .98 3/4 11/16 17/16 1% 1.06 1.10 1 s 1 As 1A6 1.18 122 11/2 1/8 1/8 F3/16 1.45 1.40 2 21/s 21/s 1/s 1.70 1.82 1/2 11/2 115/16 111/16 115/16 1.35 1.42 3 14 1 '/2 115/16 1/4 115/i6 1.41 1.56 %1½15As 1 3/4 1M0 103 1 11/2 115/is 113/16 11 '/16 1.50 1.54 11/4 113/16 111/16 1/8 1.30 1.44 1 15/s 1 11/2 113/i6 1.15 1.18 1/2 11/4 1/2 17/16 13/s F1/is 1.03 1.10 3/4 11/2 17/16 1/4 1.08 1.10 1 1½ 1½6 s 126 1 .27 1Vi 113/i6 1 '/4 P/s 1.52 1.42 11/2 115/16 111/s 115/is 1.50 1.55 11/2 1/2 17/16 1/16 111/16 1.19 1.25 3/4 11/2 11/2 1/4 1.29 1.40 1 1/a 1/s 113/16 1.44 1.49 11/4 113/is 11 '/16 1/s 1.45 1.47 2 23A6 2 1.86 2.01 1/2 2 21/4 1/a 21/4 2.14 2.25 3/4 2 21/4 115/16 21/4 2.00 1.97 1 1 2 2½ 2 21/4 1 2.14 2.28 11/4 11/4 li/s 1/4 21/8 1.72 1.79 11/2 2 1/s 2 /16 1.85 2.00 2 21/4 21/s 21/4 2.20 2.25 2 11/ 1 1/4 1/s 2 1.58 1.61 11/4 li/i - 113/is - 1 ; A /16 21/a 1.76 1.83 - 11/2 2 2/16 1.95 1.95 2 2V4 23/is 21/4 2.24 2.39 2 1/2 11/2 11/2 1 7/ 1.65 1 .70 3/4 15/s 15/s 1 2 1 1.87 1.90 1 1/4 1/4 2 1.79 2.00 11/4 P/s 1/a 21/8 2.35 2.55 11/2 2 2 2/16 2.55 2.65 21/2 2/i 21/o 2/ 3.50 3.59 Size (NPS) x (in) y (in) z (in) Wt. (Ibs) jjj 1 1 2 23/s 23/16 2/8 3.43 3.51 21/2 211/16 21/2 211/is 3.80 3.80 2 2 2% 21/4 21/s 3.28 3.32 21/2 211/is 2/a 211/is 3.65 4.10 2/2 21/2 3/4 1 '/4 1/4 25/16 2.82 2.80 11/4 2 V1 21/i6 27/16 3.34 3.47 - 11/2 23/is - 2/is 21/2 3.46 3.57 2 2/s 23/s 25/s 3.65 3.75 3 3 3 213/16 1 5.82 6.00 2 2 21/2 21/4 2% 4.10 4.30 3 31/8 21/8 31/8 6.07 6.53 21/2 2 21/2 2/s 21/8 4.80 4.85 - - 21/2 213/16 211/16 3 5.80 5.91 3/4 1/ 1/a 2/8 4.02 4.22 1 2 2 25/8 4.15 4.36 11/4 23/i6 2/4 4.68 4.67 11/2 25/16 25/i6 213/16 5.11 5.26 2 21/2 21/2 21/s 5.79 5.81 2V2 213/is 213/is 3 6.09 6.22 3 4 313/16 35/s 313/16 11.80 11.00 4 2 23/4 23/4 3'/16 8.39 8.80 21/ 3V16 31/is 31/2 9.80 9.25 3 3/16 13/is 1 35/s 11.02 111.30 fl www.anvilintl.com (12/10/01) Malleable Iron Threaded Pipe With Unions Pressure -Temperature Ratings Temp (°F) Pressure, (psig) Class 150 Class 250 Class 300 -20° to 1500 300 500 600 2000 265 455 550 250° 225 405 505 300° 185 360 460 350° 150 315 415 400° 110 270 370 450° 75 225 325 500° -- 180 280 550° -- 130 1 230 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F ANVIL INTERNATIONAL, INC. S Malleable Iron Threaded Fittings Pressure -Temperature Ratings Temp Pressure, (psig) Class Class 300 150 Sizes 1/411 - 1" Sizes 11/411 - 2" Sizes 21/2".3" -20° to 150° 300 2,000 1,500 1,000 200° 265 1,785 1,350 910 250° 225 1,575 1,200 825 300° 185 1,360 1,050 735 350° 150 1,150 900 650 400° -- 935 750 560 450° -- 225 600 475 500° -- 510 450 385 550° - 300 300 300 Anvil Class 150 (Standard Weight) Malleable Iron Fittings conform to ASME B16.3 and Unions conform toASME B16.39. Anvil standard weight banded pattern fittings in this catalog, sizes 'Ia NPS to 6 NPS inclusive, are included in the "List of Inspected Fire Protection Equipment and Materials" issued by the Underwrit- ers' Laboratories, Inc. ALL ELBOWS & TEES %' AND LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. www.anvilinti.com (12/10/01) S 105 BEAM CLAMP 1 1/4 " MOUTH SIZE - 3/8" and 1/2' rod. MATERIAL - Ductile iron with hardened cup point set screw and jam nut. FINISH - Plain, Electro-Galvanized and H.D.G. and Stainless Steel. LISTINGS - Sus Approval guide - Pipe Hangers CONFORMS WITH: Federal Specification WW-H-17 1E Type 19 and 23 and Manufactures Standardization Society ANSI/MSS-SP-58 Type 19 and 23. FUNCTION - Hanger assembly attachment to steel flange with thickness of less than 1 1/4". INSTALLATION - Per NFPA- 13 with set screw up or down. Install in accordance with ANSI/MSS-SP-69. Torque - 3/8= 60 inch pounds. Torque - 1/2= 125 inch pounds. In the absence of a torque wrench, engage set bolt finger tight then additionally tighten 1/3 turn. FEATURES * Maintains CONSTANT HANGER CENTER-LINE, with set screw up or down. * Flat throat back prevent twisting during installation. ORDERING - Part #, rod size and finish. 9 12/03 WOOD JOIST SH.00T!C ST DO I OR RAFTER ROD BARD S505ER MAX ANGLE B' Eliminates distortion of threaded rod. Accommodates up to 3 1/0 x 12 pitch roof. Allows 170 deflection from vertical. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. #14 Black J• 3/8' 8139957 SH-GST 20 1/4 x 2" 1257 (Fir) Nut Driver Part# 813910't_ 3/8' 8141957 SHGST 30 1/403" 1720 (Fir) 1903 Dim. Lumber I 3/8" 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45"otf vertical I Dim. Lumber 1 903 Dim. Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 x 13/40 1406 @ 45"off vertical L Dim. Lumber * May require pre-drilling; consult joist manufacturer. #14 SH Orange Nut Driver Part # 8273910 1500 850 @ 45" 1475 1475 25 125 25 125 ZLIZEfflyz @ Not less than 2' nominal width ___________________________ (1-1/2') up to 3-1/2' pipe; not less than 3' (2-1/2') nominal width 4' & 5' pipe 4 FloorJoi requirement shall not apply to 2' or Minimum 2-1/2' from bottom for __________ branch lines. Minimum 3" from bot- tum for mainlines. Exception: This A* thcker nailing strips resting on top of steel beams. No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. Watch a video demonstration F:. www.itwbuildex.comJ 1/4 8019957 3/8" 8023957 3/8 8021957 3/8" 8073925 318" 8022925 #14 SW Red 38" 8023925 Nut Driver Part #8114910 May require pre -drilling; consult joist manufacturer. SWG 200 1/4x2" 1725 (Fir) 25 125 SWG 10 1/4 xl" 622 (Fir) 300 25 125 SWG 20 114x 2" 1725 (Fir) 1050 25 125 SWG 20-SS 1/4 x 2" 1725 (Fir) . 850 25 125 SWG 25-380 3/80 2-1/2 2249 (Fir) 1500 25 125 SWG 30 1/4x 3' - 1884 (Fir) - 25 125 300 RING HANGER 1 thru 4 inch pipe LISTED FOR STEELICPVC 1/2 and 3/4 inch pipe 5 thru 8 inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTINGS - u C° US EX 2551 'c:S> Approval guide - Pipe Hangers CONFORMS WITH: Federal Specification WW-H- 171 (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE - 6500F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION - Per NFPA-13, 13R and 13D. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. Note: On Copper - Insulate pipe. REC. LOAD LBS. METRIC* PIPE ROD W IMPERIAL MAX 400 10 400 20 10 400 25 10 11/4 3/8 400 32 10 11/2 400 40 10 2 3/8 400 50 10 21/2 600 65 10 3 3/8 600 80 10 31/2 3/8 600 10 4 3/8 1000 100 to 5 1/2 1250 125 12 6 . 1250 iso 12 8 1250 200 12 Order Part #300m Note: 1/2 Ring Hanger not <FM> approved 08/03 fl P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444 3887 www. Afcon.org 650 ALL THREADED ROD 10'- O' LENGTHS ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 1/4 240 215 3/8 610 540. 1/2 1130 1010 5/8 1810 1610 3/4 2710 220 7/8 3770 3360 i 4960 4420 11/4 8000 7140 11/2 11630 1037) NOTE; maximum Temperature: 75C-°F SIZE - 1/4 thru 1 1/2 inch rod in 10' - 0" lengths. MATERIAL - Carbon Steel. FINISH - Plain and E.G., ORDERING - Part #, rod diameter and finish. S S 12/10 C 162 UNIVERSAL - RETAINING STRAP Nut optional, if insufficient rod dimension S SIZE- One size fits both 3/8" and 1/2" rod or set screw. Available lengths 4" and longer. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - YL c us EX 2551 PATENT - No. 5,897,088 FUNCTION - To offer more secure fastening of Beam Clamp to beam when danger of movement might be expected. INSTALLATION - Install tight to structure and component parts Minimum return on strap: 1" FEATURES * Fast installation for new construction or retrofit. * Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component parts per good installation practice (See drawings provided) ORDERING - Part # and L dimension. /AcSn 310 SURGE RESTRAINER Ring Hang I I I I I I I I I estrainer LI I I I I SIZE - Fits 3/4 thru 4 inch Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING - UL in US and CANADA. Only listed for use with AFCON Ring Hanger. FUNCTION - Used with Ring Hanger to restrict upward movement of piping. Use with steel or C.P.V.C. pipe. INSTALLATION - Snap into locking position on swivel nut of Ring Hanger. Install or remove without tools. FEATURES - Ring Hanger may be adjusted with Surge Restrainer installed. ORDERING - Part #. Index CD 12/00 S Component of State of California OSHPD Approved Seismic Restraints System H > Fig. 909 - No-Thread Swivel Sway Brace Attachment Size Range - 1" bracing pipe. For brace pipe sizes larger than 1", use TOLCO Fig. 980. Material - Carbon Steel, hardened cone point engaging screw Function - The structural component of a sway and seismic bracing system. Features - This products design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates clear- ly that fastener table load values are based only on concentric loading. Open design allows for easy inspection of pipe engagement. Application Note - The required type, number and size of fasteners used for the structure attachment fitting shall be in accordance with NFPA 13 and/or OSHPD. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation - The Fig. 909 is the structural or transitional attach- ment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 4A, 413 or 4L to form a .complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 909 onto the bracing pipe. Tighten the set bolt until head bottoms out on surface. Attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in Electro-Ga Ivan ized and HDG finish. Order By - Figure number, pipe size and finish. V Lateral Brace Dimensions Weights Max. Design. Max. Design Load Approx. PiDe Size A B H* Load Lbs. Lbs. wiWasher Wt./100 1 6 1 V8 17/32 2015 2765 91 * Available with hole sizes to accommodate up to 3/4 fastener. Consult Factory. .TOLCO® brand bracing components are desgined to be compatible Q.NJ_Y with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLJQQ brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMI-'su1Tv. • CORONA, CA 92879. PH 951.7375599. FAX: 951.737.0330 CUSTOMER SERVICE . 800 786 5266 www.tolco.com Fig. 1000 - "Fast Clamp" Sway Brace Attachment Component of State of California OSHPD Apprmve Seismic Restraints System Size Range - Pipe size to be braced: 1 thru 6' Schedule 10 thru 40 lPS.* Pipe size used for bracing: 1' and 11/4" Schedule 40 'PS. * Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 - 8 ft. lbs. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace sys- tem: Fig. 1000 is used in conjunction with a TOLCO Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features - Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation - The Fig. 1000 is the braced pipe attachment component of a lateral sway brace assembly. It is intended to be combined with the bracing pipe and TOLCO structural attach- ment component, Fig. 980, 910 or 909 to form a complete bracing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install - Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1 ' extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is recommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note - Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Maximum Design Load 1 thru 4" pipe size - 2015 lbs. 6' size - 1265 lbs. FM Approved Design Loads* 1' - 21/2" - 600 lbs. 3" - 4" - 700 lbs. C®US LISTED TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. 0 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879. 1.737.5599.FA.951.737.0330 CUSTOMER SERVICE • 800.786 5266 Www.folco.com P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 ATTACHMENT FITTING LOCKING I 17/32' WI 17. . SIZE - BRACE PIPE: 1" and 1 1/4" Sch. 40 MATERIAL - Carbon Steel, Ductile Iron or S.S. (Type 304). FINISH - Plain or E.G. LISTING/APPROVAL - c®us USTED 203A-EX2625 FM Approved - 1950 OSHPD See Website. FUNCTION - Structure attachment fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 FM 2-8. Load rating - see chart. ASSEMBLY Combine with proper AFCON components- see disclaimer below. Insert brace pipe thru fitting near pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * Swivel allows attachment at any angle. * Visual inspection, verifies proper installation. * Larger fastener hole available.- Consult factory. ORDERING - Part #, size - brace pipe and finish. Max. Horizontal Load Size 1-2 ® T:~;- Ductile Base 2015 1500 Steel Base 2015 --- 40 Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, ports or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 3/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 001/020 SWAY BRACE FITTING MODEL E Part #077 mm. Load Ratings SizE -SYSTEM SYSTEM PIPE. Nominal 10 3ch. 40 1 Sch. Steel 1" thru 4" Sch. 10 and Sch. 40 250 1000 1 1I 250 1000 SIZE - BRACE PIPE: 1" or 1 1/4' Sch. 40 11/2 250 1000 MATERIAL - Carbon Steel or S.S. (Type 304). 2 1000 _j 21/2 800 1 ___ FINISH - Plain or E.G. 3 800 1300 LISTING/APPROVAL - 4 800 1500 $' FM Approved - 1950 OSHPD See Website. FUNCTION - Lateral fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 and 13R. Load rating - see chart. Align brace pipe perpendicular to system pipe. ASSEMBLY - See drawing. Combine with proper AFCON components- see disclaimer below. Insert brace pipe through rod bend and under channel bracket to achieve minimum 1" extension. Tighten hex nuts until gage spring lays flat or torque to 165 in-lbs. FEATURES * Visual inspection, verifies proper installation. ORDERING - Part #, size - system pipe, size - brace pipe and finish. c>1 1 . Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, reslraine ar hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER. AFCON will NOT warrant against the failure of its products when used in combination with other products, ports or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any knd, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 3/13 SHOWN WITH FIG. 980 BRACE FITTING TO PIPE BRACE (ALONG BEAM) S Fig. 800 - Adjustable Sway Brace Attachment to Steel Size Range - 4" thru 18" beam width Material - Carbon Steel Function - Seismic brace attachment to steel. Features - This product's design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure connection to steel where drilling and/or welding of brace connection could present structural issues. Installation Instructions - The Fig. 800 is the structural attachment com- ponent of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, "bracing pipe' and a TOLCO "braced pipe" attachment to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 800 on the steel beam, tighten the cone point set bolts on flange until bolt heads break off. Tighten hex head bolts into clamp body until lock washers are fully flat. Attach other TOLCO transi- tional attachment fittings, Fig. 909, 910 or 980. Transitional fitting attach- ment can pivot for adjustment to proper brace angle. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional S load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, type number and size number. WJ C®US LISTED Component of State of California OSHPD Approved Seismic Restraints System SHOWN WITH FIG. 980 BRACE FITTING TO PIPE BRACE (ACROSS BEAM) Dimensions • Weights Max. Design Loads/Lbs. (cULus) *Max. Design Loads/Lbs. (FM) Fits Beam Along Across Along Across Size Range (In.) Beam Beam Beam Beam 1 4-6 1265 2015 2800 2800 2 6-8 1265 2015 2800 2800 3 8 -10 1265 2015 2800 2800 4 10-12 1265 2015 2800 2800 5 12 -14 1265 2015 2800 2800 6 14-16 1265 2015 2800 2800 7 16-18 1265 2015 2800 2800 Dimensions • Weights Max. Design Loads/Lbs. (cULus) *Max. Design Loads/Lbs. (FM) Flange Thickness Along Across Along Across Type Max. (In.) Beam Beam Beam Beam 1 3/4 1265 2015 2800 2800 2 11/4 1265 2015 2800 2800 * Load shown is allowable with brace installed, between 30° - 90°. No reduction of load based on brace angle is required. TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed S seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH 951737 5599 • FAX: 951737 0330 CUSTOMER SERVICE • 800786 5266 www.tolco.com Fig. 4L Longitudinal "In-Line" Sway Brace Attachment Size Range - 21/2" through 8" IPS. Material - Carbon Steel *40 Function - For bracing pipe against sway and seismic disturbance. Features - This product's design incorporates concentric loading of the "brace pipe", connection components and fasteners which is critical to the performance of seismic bracing assemblies. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 21/2" through 8'. Installation - The Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish - Plain Note - Available in electro-ga Ivan ized and HDG finish. Order By - Figure number, pipe size and finish. 4-Way Riser Brace (Plan view) Longitudinal Brace Dimensions 'Weights Bolt Max. Rec. Approx. Sizes A C D Size Load Lbs. Wt./100 2½ 6V16 2½ 2Y4 1/2 2015 253 3 7 2Y4 31/16 1/2 2015 268 4 8½ 3% 311/16 1/2 2015 348 5 9Y4 3½ 4% 1/2 2015 380 6 11½ 5 51A 1/2 2015 640 8 131/4 611A6 6½ 1/2 2015 728 TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seis- mic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. . CORONA, CA 92879 . PH: 951.737.5599 • FAX: 951.737,0330 A CUSTOMER SERVICE . 800 786.5266 www.tolco.com 410 SWAY BRACE CLAMP SIZE - I thru 8 inch pipe. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized, H.D.G and Stainless Steel. LISTINGS - *us EX 2625, EX 2551 Listed only for use with other AFCON bracing products. OSHPD pending. FUNCTION - Pipe attachment component of a longitudinal or 4-way sway brace, consisting additionally of AFCON 70 series attachment end, AFCON 80 series adapter as required and brace pipe element forming a complete sway brace assembly. INSTALLATION - Per NFPA-13. Assemble 410 over pipe to be braced, install 70 series attachment end on outside of clamp ears and tighten bolts to minimum required torque of 40 ft.lbs. 078 is the preferred brace pipe attachment component at the 410 of a longitudinal sway brace assembly - see drawing FEATURES * UL Horizontal Load Rating: 1-3 pipe size = 500# 4-8 pipe size = 2015# * Made with 1/2' bolts to conform with sway brace fittings. ORDERING - Part #, pipe size and finish. Part #41 E 06/03 Worldwide tqcLl Contacts Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage ... General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condn. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) 1Y313 .......Upright 5.6K, 1/2" NPT 1Y323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar1/2) Temperature Rating 135-F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) JANUARY 2013 Finishes Sprinkler: Natural Brass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze - TFPI72 I- _ S 4;. TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 1 7/16' (11,1 mm) NOMINAL MAKE-IN 2 ' (50,8 mm) 1 1/2' NPT** 2' (50,8 mm) / WRENCH FLATS DEFLECTOR * F- 2-7/8' (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE S S ^WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) 2-1/4' DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) 3/8±5/16 I FLUSH (9,5±7,9 mm) / - MOUNTING 1/8" SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. - (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. FITTING (57,2 mm) 5/16±1/4 FLUSH / (7,9±6,4 mm) 1/2" (12,7 mm) MOUNTING / \ 1/8' ] I SURFACE/ \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TYFRB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 PIN* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2 NPT) 1Y313 4 SIGNAL WHITE (RAL 9003) 371 5.6K PENDENT (1/2 NPT) TY323 Use suffix "1° for ISO 7-1 connection; for example, 77-370-4-175-I 3 PURE WHITE (RAL 9010)* 9 CHROME PLATED Eastern Hemisphere sales only 135 135°F (57°C) 155 155°F(68°C) 175 175°F(79°C) 200 200°F(93°C) 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS - PART NUMBER SELECTION - Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (SIN), K=5.6, (Upright or Pendent) Sprinkler Quick Response, (specify) temperature rat- ing, (specify) finish, P/N (Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation. tqco A INSPECTORIsTEST Model 3011 F Remote Inspector's Test for Single Story and Other Applications Including Systems Requiring Pressure Relief Valve CUS ED 1" APPROV • The AGF Manufacturing Inc. Model 3011 INSPECTOR'STEST® family of valves are designed to perform the remote inspector's test function on single story and other applications with the benefit of locating the orifice indoors. The Model 3011 INSPECTOR'STEST® is available in four different models: - Model 3011 BV ball valve only - Model 30IISG ball valve with sight glass - Model 3011A ball valve with Model 7000 Pressure Relief Valve and drainage piping - Model 301 1ASG ball valve with sight glass, Model 7000 Pressure Relief Valve, and drainage piping Available with test orifice sizes of %" (2.8K), 7A6" (4.2K), ½" (5.6K), 17/32" (8.0K), and 5/8" (11 .2K, ELO). The Models 3011A and 3011ASG have the added feature of a Model 7000 Pressure Relief Valve with drainage piping designed to relieve excess system pressure caused by surges or temperature changes as well as solve the difficult problem of providing the relief valve with a drainage piping outlet. The Models 301 IA and 30IIASG comply with the requirements of NFPA-1 3 for the installation of a pressure relief valve on all gridded systems and downstream of all pressure reducing valves. The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is rated at 175 PSI. Other pressure settings are also available. (see note below) To expedite system testing, the unit is shipped semi-assembled with relief valve and bypass drain ports plugged. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. INSPECTORSTEST is registered trademark of AGF Manufacturing Inc. CS3011 3/08