HomeMy WebLinkAbout2080 LAS PALMAS DR; ; FPC2019-0245; PermitPERMIT REPORT (City of Carlsbad Print Date: 12/02/2020 Job Address: 2080 LAS PALMAS DR, CARLSBAD, CA 92011-1570 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2130611500 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0245 Status: Closed - Finaled Applied: 10/21/2019 Issued: 10/31/2019 Finaled Close Out: 11/27/2019 Inspector: Final Inspection: Project Title: Description: PALOMAR AIRPORT BUSINESS PARK -FIRE ALARM SPRINKLER MONITORING SYSTEM (ZONE) Applicant: FPContractor: JOHNSON CONTROLS SECURITY SOLUTIONS JOHNSON CONTROLS SECURITY SOLUTIONS LLC LLC - DONOTUSE MALCOLM D'COSTA 3870 MURPHY CANYON RD, # 140 3870 MURPHY CANYON RD, # 160 SAN DIEGO, CA 92123-4403 SAN DIEGO, CA 92123-4403 (561) 226-8210 (619) 805-5300 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov f?C'M1q--0zje5 IIIGHLIGHTED SET Cut Sheets and CSFM Listing Sheets For: Palomar Airport Business Park 2080 Las Palmas Drive Carlsbad, California 92008 Installer: Johnson 01(i Controls tq U /ntegrated Security 3870 MURPHY CANYON ROAD SUITE 140 SAN DIEGO, CA. 92123 (800) 289-2647 LIC #977249 (C-b, C-7) DF-5241 6:D • A3-20 (S-5UD(E)lMS-1 OUD(E) Series ve Zone Fire Alarm Control Pa Ten Zone Fire Alarm Control Panel (a Fire LIT®ALS by Honeywell General The MS-5UD-3(E) is a five-zone FACP (Fire Alarm Control Panel) and the MS-i OUD-7(E) is a ten-zone FACP. These con- trol panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional build- ings. Both panels include built-in communicators for Central Station Service and remote upload/download. Each of these FACPs is compatible with System Sensor's microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 1OUD-7 are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterf low devices, tamper switches, and other normally-open contact devices. Refer to the Fire-Lite Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special applica- tion resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. New options include a UL listed printer, PRN-6F and FireLite's IPDACT Internet Monitoring module. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD per- mit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The MS-5UD-3E and MS-10UD-7E offers the same fea- tures as the MS-5UD-3 and MS-10UD-7 but allow connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-listed models, see DF-60440. Features Listed to UL Standard 864, 9th edition. Built-in DACT (Digital Alarm Communicator/Transmitter). Style B (Class B) lDC (Initiating Device Circuit) - MS-5UD-3 - five lDCs. - MS-10UD-7 - ten lDCs. Style Y (Class B) NAC (Notification Appliance Circuit) - spe- cial application power - MS-5UD-3 - four NACs. - MS-10UD-7 - four NACs. Notification Appliances may be programmed as - Silence Inhibit. - Auto-Silence. - Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. - Selective Silence (horn-strobe mute). - Temporal or Steady Signal. - Silenceable or Nonsilenceable. Optional CAC-5X Style Z (Class A) Converter Module for NACs and lDCs (2 required for MS-10UD-7). Form-C Relays for Alarm, Trouble and Supervisory - Con- tact Ratings 2.0 A@ 30 VDC or 0.5 A @ 30 VAC (resistive). 3.0 A total system current for MS-5UD-3. 7.0 A total system current for MS-10UD-7. Optional Dress Panel DP-51050 Optional Trim Ring TR-CE for semi-flush mounting. 24 volt operation. Low AC voltage sense. Alarm Verification. PAS (Positive Alarm Sequence). Automatic battery trickle charger. Up to eight ANN-BUS annunciators: - Optional 8 zone Relay Module ANN-RLY. - Optional LED Annunciator Module ANN-LED, - Optional Remote Annunciator ANN-80. - Optional Remote Printer Gateway ANN-S/PG. - Optional LED Annunciator Driver ANN-I/O. Optional 4XTMF module (conventional reverse polarity/city box transmitter). PROGRAMMING AND SOFTWARE: Can be programmed at the panel with no special software or additional equipment. Programmable Make/Break Ratio. Upload/Download (local or remote) of program and data via integral DACT. DF-52416:D • 07/26/2010 - Page 1 of 4 Door = 19.260 (48.92 cm) Backbox = 19.0° (48.26 cm) USER INTERFACE: Built-in DACT (Digital Alarm Communicator/Transmitter). Integral 80-character LCD display with backlighting and keypad. Real-time clock/calendar with automatic daylight savings adjustments. ANN-BUS for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL Terminal Blocks AC Power —TB1: MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 50/60 HZ, 1.00 A. MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 50/60 HZ, 3.80 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50/60 HZ, 2.20 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 A. Supervised, nonpower-limited. Maximum Charger Capacity: 18 A battery for MS-5UD- 3(E), and 26 AH battery for MS-10UD-7(E). [Two 18 Ah bat- teries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55.] Top Depth =5207 (13 23 cm) _______ = Door = 16.821° (42.73 cm) Depth I ii257°I Backbox = 16.65° (42.29 cm) (13.353 cm) Left Side Right Side Bottom Cabinet Measurements Page 2 of 4— DF-524160 • 07/26/2010 Minimum Battery Size: 7 AH. Initiating Device Circuits - T134 (and TB 6 on MS-i OUD-7 only): Alarm Zones 1 - 5 on TB 4 (MS-5UD-3 and MS-10UD-7). Alarm Zones 6- 10 on TB6 (MS-1 OUD-7 only). Supervised and power-limited circuitry. Operation: All zones Style B (Class B). Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 ohms. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL- listed). Standby Current: 2 mA. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Notification Appliance Circuits - T135 (and TB 7 on MS- 1OUD-7 only): Four NACs Operation: Style Y (Class B) Special Application power Supervised and power-limited circuitry Normal Operating Voltage: Nominal 24 VDC Maximum Signaling Current: 3.0 A for MS-5UD-3, 2.5 A maximum per NAC; 7.0A for MS-10UD-7(E), 3.0A maxi- mum per NAC. End-of-Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) Max. Wiring Voltage Drop: 2 VDC Refer to the Fire•Lite Device Compatibility Document for com- patible listed devices. Form C Relays - TB8: Relay 1 (factory default programmed as Alarm Relay) Relay 2 (factory default programmed as fail-safe Trouble Relay) Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - T139: Jumper selectable by JP31 for resettable or nonresettable power. Operating voltage: 24 VDC nominal. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors. Power-limited circuit. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output - T132: Remote power supply synchro- nization output, only required for the MS-5UD-3. 24 VDC nom- inal special application power. Maximum current is 40 mA. End-of-Line Resistor: 4.7K ohm. Supervised and power-lim- ited circuit. Product Line Information MS-5UD-3: Five-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-3 power supply, technical manual, and a frame & post operating instruction sheet). 120 VAC operation. MS-51JD-3E: Same as MS-5UD-3 except for 240 VAC opera- tion. MS-10UD-7: Ten-zone, 24-volt Fire Alarm Control Panel (includes backbox, FLPS-7 power supply, technical manual, and a frame & post operating instruction sheet). MS-i OUD-7E: Same as above with 240 VAC FLPS-7. IPDACT, IPDACT-212UD Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for Internet communications over customer provided ethernet internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 for more information.) IPBRKT: Mounting kit for IPDACT in common enclosure. IPSPLT: Y Adaptor option to allow connection of both panel dialer outputs to one cable input to IPDACT (sold separately). OPTIONAL MODULES CAC-5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Connects to J2 on the MS-5UD-3 and MS-10UD- 7(E) main circuit board and to J7 on the MS-10UD-7(E). NOTE: Two Class A Converter Modules are required for the ten- zone panel. 4XTMF: Transmitter module. Provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble LED. A module jumper option allows the reverse polarity circuit to open with a system trouble condition if no alarm conditions exists. Mounts to the main circuit board connectors J4 and J5. COMPA TIBLE ANNUNCIA TORS ANN-80: Remote LCD Annunciator. Mimics the information displayed on the FACP's LCD. Red. (For white, order: ANN- 80-W.) ANN-LED: LED Annunciator with three LEDs for each zone: Alarm, Trouble, and Supervisory. Mounts in the DP-51050(B) dress panel. Red. (For white, order ANN-LED-W.) ANN-RLED: LED Annunciator with three alarm (red) indica- tors for up to 30 input zones or addressable points. (Red. For white, order ANN-LED-W.) (See DF-60241). ANN-RLY: Relay module. Mounts inside the cabinet. Provides ten Form C relays. ANN-S/PG: Serial/parallel printer gateway. Provides a connec- tion for a serial or parallel printer. ANN-I/O: Driver module. Provides connections to a user-sup- plied graphic annunciator. ACCESSORIES DP-51050: Optional dress panel. Restricts access to the sys- tem wiring while allowing access to the membrane switch panel. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55: Battery backbox, holds up to two 25 AH batteries. TR-CE: Optional trim-ring for semi-flush mounted cabinets. PRN-6F: UL listed printer. DF-52416:D • 07/26/2010 - Page 3014 SYSTEM SPECIFICATIONS System Capacity Annunciators .8 Electrical Specifications MS-5UD-3 (FLPS-3 Power Supply): 120 VAC, 60 HZ, 1.OA MS-10UD-7 (FLPS-7 Power Supply): 120 VAC, 60 HZ, 3.90 A MS-5UD-3E (FLPS-3 Power Supply): 240 VAC, 50 HZ, 0.54 A. MS-10UD-7E (FLPS-7 Power Supply): 240 VAC, 50 HZ, 2.20 A. Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: —20.00" (50.80 cm.) high —22.5" (57.15 cm.) wide - 8.5" (21.59 cm.) deep. Weight: 27 lb (12.20 kg) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F Agency Listings and Approvals The listings and approvals below apply to the basic MS-5UD-3 and MS-10UD-7 control panels. In some cases, certain mod- ules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL Listed: File S624 FM Approved CSFM: 7165-0075:0214 MEA: MEA: 333-07-E NOTE: For ULC-listed models, see DF-60440. NFPA Standards The MS-5UD-3(E) and MS-10UD-7(E) complies with the fol- lowing NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Network) FireLite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. d I I .1 We cannot cover all specific applications or anticipate all requirements. 111111*31111116 MNMC1UIIINO All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4014— DF-52416:D • 07/26/2010 Calculating the System Current Draw Power Supply Calculations 7.3 Calculating the System Current Draw 7.3.1 Overview The control panel must be ablcto'power all internal and external devices continuously during the non-fire alarm condition. To calculate the non-fire alarm load on the system power supply when primary power is applied, use Calculation Column 1 in Table 7.3 on page 118. The control panel must support a larger load current during a fire alarm condition. To calculate the fire alarm load on the power supply, use Calculation Column 2 in Table 7.3 on page 118. The secondary power source (batteries) must be able to power the system during a primary power loss. To calculate the non-fire alarm load on the secondary power source, use Calculation Column 3 in Table 7.3 on page 118. When calculating current draw and the battery size, note the following: Primary' refers to the main power source for the control panel Secondary' refers to the control panel's backup batteries All currents are given in amperes (A). Section 7.2 shows how to convert milliamperes and microamperes to full amperes. To convert... Multiply Example Milliamperes (mA) to mA x 0.001 3 mA x 0.001 = 0.003A amperes (A) Microamperes (PA) to PA x 0.000001 300 iA x 0.000001 = 0.0003 A amperes (A) Table 7.2 Converting to Full Amperes 7.32 How to Use Table 7.3 on page 118 to Calculate System Current Draw Use Table 7.3 on page 118 to calculate current draws as follows: Enter the quantity of devices in all three columns F.ntcr the current draw where required. Refer to the Device Compatibility Document for compatible devices and their current draw Calculate the current draws for each in all columns Sum the total current for each column Copy the totals from Column 2 and Column 3 to Table 7.4 on page 119 Following are the types of current that can be entered into Table 7.3 on page 118: / Calculation Column 1 - The primary supply current load that the control panel must support during a non-fire alarm condition, with AC power applied. I Calculation Column 2 - The priniaiy supply current load that the control panel must support during a fire alarm condition, with AC power applied. 1 Calculation Column 3 - The standby current drawn from the batteries in a non-fire alarm condition during a loss of AC power. M5-5UD & US-IOUD Series Manual P/N 52626:C4 3/7/2014 117 Power Supply Calculations Calculating the System Current Draw Table 7.3 contains three columns for calculating current draws. For maximum output current avail- ability per circuit and per panel, refer to Section 1.2. "Specifications", on page 15. For each col- umn, calculate the current and enter the total (in amperes) in the bottom row. When finished, copy the totals from Calculation Column 2 and Calculation Column 3 to Table 7.4 on page 119. Calculation Column I Calculation Column 2 Calculation Column 3 Device Type Primary, Non-Fire Alarm Current Secondary, Fire Alarm Current Secondary, Non-Fire Alarm (amps) (amps) Cunt (amps) city I X[current Total Qty X [current draw] Total city X[current Total draw]= = I draw] I Main Circuit Board MS-5UD X[0.110]= X[O.21411 2_ X[0.110]= or 1 1 1 MS-lOUD X(0.1 33]=' XFO.28211 2 X10.133]= CAC-5X F. J XF0.0011= I I x[o.00l]= E I X[0.001]= 4XTMF F ] X10.0051= [ ] X[0.011J1= [ ] XF0.0051= 1 max. 1 max. 1 max. ANN-SEC card I J XF0.0031= F J X[0.003]= F J X[O.003]= I max. 1 max. 1 max. ANN-80(C) I I X(O.0371= I I X10.040]= ( ] X0.015]= ANN-I/O [ ] XO.0351= I ] X0.200] [ ] XO.035]= ANN-RLY I I X[O.015]= [ I X0.0751= F ] X[0015]= ANN-(R)LED3 I I X[O.028]= [ ] X[O.065]= [ ] X)O.028]= ANN-S/PG [ ) X[O.045]= I I X[0.045]= [ ] X0.045J= 2-wire Detector [ ] X( 1 = 1 1 ' X[0.040]= I I X[ j4= Heads 4-wire Detector [ )Xf 4= [ 1 1 X[0.040]= [ I X( 14= Heads Power [ ] X0.025]= I ] X[0.025]= [ I X[0.0251= Supervision Relays6 I NAC #1 [ ] X ] NAC #2 [ I X[ 1= NAC #3 Current Draw I 0N ot,= NAC #4 1 I from TB9 (nonalarm) Sum each I column7 for I . Primary Non-Alarm = Secondary Alarm = Secondary Non-Alarm totals Table 7.3 System Current Draw Calculations 1 If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. - 2 The current draw shown represents one zone (IDC) on the main circuit board in alarm. One zone consumes 0.040 amps. 3 An ANN-LED is supplied standard with the MS-5UDC and MS-10UDC. 4 Refer to the Device Compatibility Document for standby current. 5 Enter the number of lDCs used minus one. 6 Must use compatible listed Power Supervision Relay. 7 Total current draw listed above cannot exceed 3.25 amps for the MS-5LJD-3(E), 3.28 for the MS-10UD-3(E), 7.25 for the MS-5UD-7(CIE), and 7.28 for the MS-10UD-7(C/E). 118 MS-5UD & MS-lOUD Series Manual- P/N 52626:C4 3/7/2014 Calculating the Battery Size Power Supply Calculations 7.4 Calculating the Battery Size Use Table 7.4 to calculate the total Standby and Alarm load in ampere hours (AH). This total load determines the battery size (in All), required to support the control panel under the loss of AC power. Complete Table 7.4 afllows Enter the totals from Fable 7.3 on page 118, Calculation Columns 2 and 3 where shown Enter the NFPA Standby and Alarm times (refer to NFPA Requirements' below) Calculate the ampere hours for Standby and Alarm, then sum the Standby and Alarm ampere hours Multiply the sum by the derating factor of 1.2 to calculate the proper battery size (in All) Write the ampere hour requirements on the Protected Premises label located inside the cabinet door Secondary Standby Load Required Standby Time (total from Table 7.3 Calculation (24 hours) Column 3) } X[ J AH Secondary Alarm Load Required Alarm Time (total from Table 7.3 Calculation (for 5 mm., enter 0.084, Column 2) for 10 mm., enter 0.168) j Xf ] . = AH Sum of Standby and Alarm Ampere Hours = AH Multiply by the Derating Factor X 1.2 Battery Size, Total Ampere Hours Required = AH - Table 7.4 Total Secondary Power Requirements at 24 VDC 7.4.1 NFPA Battery Requirements NFPA 72 Local, Central and Proprietary Fire Alarm Systems require 24 hours of standby power followed by 5 minutes in alarm 7.4.2 Selecting and Locating Batteries Select batteries that mccl or exceed the total ampere hours calculated in Table 7.4. The control panel can charge batteries in the 7 All to 26 AH range. The control panel cabinet is capable of housing batteries up to IS All. Batteries larger than 18 AH require the B11-26, BB-55, or other UL listed external battery cabinet. For Canadian applications, the minimum battery size is 12 At-I and the maximum battery size is 18A H. WS-5UL) & US-IUUD Series itfanual - PIN 52626rC4 3/7/2014 119 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL fi~"4I)'7 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (165-0075:0214) Page 1 of I CATEGORY: (- - FIRE ALARM CONTROL UNIT (COMMERCIAL)) LISTEE: (E-LITE ALARMS lNC.'pne Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennettHoneywell.com DESIGN: Model MS-5UD-3,)MS-5UD-3E, MS-5UD-7, MS-5UD-7C, MS-5UD-7E, MS-10UD-3, MS-1 OUD-3E, MS-1 OUD-7, MS-1 OUD-7C AND MSIO-UD-7E Fire alarm control units. The MS-5UD series has five input zones and the MS-lOUD series has ten input zones. Both product lines have four notification appliance circuits, and three relay contact outputs for alarm, trouble and supervisory and include an integral two-line digital alarm communicator transmitter (DACT). The -3 suffix represents the 3 amp total power variant utilizing the FLPS-3 and the -7 suffix represents the 7 amp total power variant utilizing the FLPS-7. The "E" suffix represents 240 V ac 50 Hz rated products. The "C" suffix represents products that have the separately listed ANN-LED annunciator module already installed. * These Models are intended for the following applications: Local, Auxiliary, Remote station, Central Station, and Proprietary. Refer to listee's data sheet for detailed product description and operational considerations. System components: FLPS-3:; Power Supply Module FLPS-7; Power Supply Module 4XTMF; Transmitter Module CAC-5X; Converter Module ANN-LED; Annunciator Module ANN-RLY; Relay Module *ANNsEC; Secondary ANN-BUS Module *IpDACT; lP Digital Fire Alarm Communicatior RATING: *120 VAC or 230 VAC primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to manufacturer's installation manual for details. This control unit meets the requirements of UL Standard 864, 9th edition. NOTE: For Fire Alarm Verification feature (delay of fire alarm), the retard/reset/restart period shall not exceed 30 seconds. *Rev 04-23-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (Listing Expires) (Ju ne 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DISCHARGE CHARACTERISTICS AT 25 C(77 F) mill E•! U IUIlIUU - h!iU•iIL1iHhlUU UuiiI1iIU•UiLuuiiii•U. • UUIIIIIIIUUlII!AUIIIIII•U. • .. MI 11111..: UIIElF1II••IIIIII•I I 2 3 5 10 20 30 60 2 3 5 10 20 30 Discharge Time > > Chargeing Time (h) Cycle service life Ocoharge puhiharo cccflargedept coo Dinh,,,, 200 400 600 800 1000 1200 Life (cycle) 12 10 80 60 05 40 20 POWER KINGDOM Ied Lead Acid Batterlejs S Specifications Nominal Voltage 12V Rated Capacity 7Ah Dimensions Total Height 3.98 inches (101mm) Height 3.74 inches (95mm) Length 5.94 inches (151mm) Width 2.56 inches (65mm) Approximate Weight 4.52 lbs. (2.05kg) S Characteristic Capacity 770F(250C) 20h rate 7.00Ah 10h rate 6.50Ah 5h rate 5.95Ah lh rate 4.20Ah 15 min rate 3.15Ah Internal Resistance Full Charged Battery 770F(25°C) 25m0 Capacity Affected by Temperature (20h rate) 1040F(400C) 102% 77°F(25°C) 100% 32°F(00C) 85% 5°F(-150C) 65% Self-Discharge 680F(200C) (Capacity after) 3 month storage 90% 6 month storage 80% 12 month storage 60% Max. Discharge Current_77°F(25°C) 105A(5s) Terminal TI , T2 Charge (Constant Voltage,250C) Cycle I 14.5'44.9V(-24mV/°C) max. current: 2.1 A Float 13.6-43.8V(-18mVI°C) Cnncthnt Current Dincha ny ChrHctericticc (A2Ci 4.8 E. ,6[ U 10.8 F.V/TIME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 27.0 18.0 14.0 8.40 4.70 1.73 1.15 0.71 0.37 10.2V 25.7 17.1 13.4 8.06 4.55 1.70 1.13 0.70 0.36 10.5V 24.2 16.1 12.7 7.66 4.35 1.65 1.10 0.68 0.35 Constant Current Diacharp, Characteristics (Watt.25aC F.V/TIME 5min 10min 15min 30min 60min 3h 5h lOb 20h 9.60V 301 203 160 94.2 54.4 20.6 13.8 8.52 4.43 10.2V 287 191 153 90.4 52.7 20.2 13.6 8.40 4.33 10.5V 270 180 145 86.0 50.4 19.6 13.2 8.17 4.21 System Sensor i.1",'-series smoke detectors represer significant advancement in conventional detecti The I family is founded on three principles: instaI, SYSTEM $ SENSOR® Photoelectric Smoke Detectors ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings & <~> LISTED APPROVED 3011446 Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. P detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityofi3 detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire il detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Cj Smoke Detector Specifications Smoke detector shall be a System Sensor P Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pie-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage (Standby Current) wire: 50 hA maximum average; 4-wire: 50 pA maximum avd (Maximum Alarm Current) 20 mA@12V, 23 mA@ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @30 V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freezelrouble 2W1-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal InputTerminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Thermal Wiring Alarm Current (ir) (130 mAi1ted by control pa() 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12 V, 23 mA @ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6,6 inch (16.76 cm) diameter C2OO9 System Sensor. 3825 Ohio Avenue. St. Charles, IL 60174 Product speQficat n s subjeatnchangewtnutnoce'diitsystemsensor.cnm for U5 SENSOR Phone: 800-SENSOR2. Fax: 630-377-6495 urrentPod,,ctInrocmaor including theIatestvero,,ofthisdata sheet AOS-0318-007.6/09.#2 69 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7272-1653:01:) Page 1 of I CATEGORY: (7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC) LISTEE: (ystem_Sensor,Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: (Models 2W-ë)2WT-B, 4W-B and 4Wr-Bphotoelectric type smoke detectors. Models 2W-B) and 2W1-13 are 2-wire and model 4W-B and 4W1-B are 4-wire detectors. Models 2W1-B and 4W1-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (June 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 6/18/2014 System Sensor 2-wire Corrpathilityfor MS-5UD-3 by Fire-Lite (2-wire CompaflbUity) ufacturer: Fire-Lit) (Model: MS-5Uô) N/A/CAC- 4.7K/ 2151 (T) 1B110LP, 6401 120 B,D B) 1 5X (2W - çN7CAC-) 47K / cA [N/A '20 N/A /CAC- [BD* 4.7KI A 5X N/A 2WIA-B N/A 20 CAC B, D* 4]K/ A 2WTR-B N/A 1 N/A/CAC- [BD* J4.7K/ A 5X N/A 511 B110LP, 20 N/A/CAC- B ' D 4.7K! A B401 5X N/A N/A/CAC- H 47K! [ JA D2 N/A 20 B,D http:/I1ifesafetmag 1/1 Telguard TG-7FS Sole Path Cellular Alarm Communicator for Commercial Fire System Specifications Standard Features Full data reporting Automatic self-test (5 minute, daily, weekly or monthly) Power supply with battery harness Locking, red metal enclosure Two programmable supervisory trip outputs Alarm format support for SlA2, Contact ID, pulse (3xl, 42), modem lie, & 111a2, DMP Telephone line monitor built-in Physical Details 75"H x 11.5W x 3.5"D, Weight: 8 lbs. Operating environment: 0°C to +50°C; up to 95% humidity (non-condensing) Advanced Reliability Available relay output for tripping the alarm control panel when a trouble condition occurs Automatic Self-Tests with central station notification ensure the cellular system is operating 128 bit AES (Advanced Encryption Standard) alarm signals ensure authentication and security Accessories ACD-35/50/100 feet of low loss, high performance cable HGD-0 High gain, directional antenna LPD-0 Low profile, high gain antenna EXD-0 External, high gain antenna UL Listings Commercial Fire Listings 864 - Control units and accessories for alarm systems Commerical Burglary Listings 365 - Police station connected burglar alarm units and systems 1610- Central station burglar alarm units Residential Listings 985 - Household fire warning systems 1023 - Household burglar alarm systems Power Transmit power 1.0-2.0W (maximum allowable) Current consumption 60mA (stand-by) 250mA (transmission) Transformer supplied: 12VAC, 800mA UL listed plug-in Radio Transceiver Dual band cellular and PCS GSM 850MHz: Class 4 12 watts) GSM 1900MHz: Class 1 (1 watt) Antenna 9" dipole with 2dBi gain with 12 feet of cable and universal mounting bracket FCC part 15, 22, 24 & 68 compliant LEDs 2-5 LED I fi 001 0 U -- Dill At - o•uu 3 BCfl --- 1 D011 At M 0 03 -- DOlU Co 0DDU CL .9. ODD. 0000 hi 0000 61 LI1L:LDi.c1= 03 0-4 r 91 51~ 0 CD Sx HO ø—u 2.4u G) - 0 m7. TOTG-7FS LED B LED 7 LEO B LEO 5 LEO 4 LED 3 LED 2 LEO I m m 0 o z SD S S 001 01005 0 1 u_ 1300 - IRS 0 Telguard Model TG-7FS QUICK INSTALLATION GUIDE [SOLE PATH] Installation Summary There are seven steps in installing Telguard properly. IF YOU DO NOT PROCEED IN THE ORDER AND MANNER PRESCRIBED, YOU MAY NOT COMPLETE THE INSTALLATION IN THE TIME ALLOCATED. STEP 1: REGISTER FOR CELLULAR SERVICE Complete the Registration Form online at wwwTelguard.com or fax the form to Telguard Customer Service prior to leaving for the job site. Telular requires this information to register and activate the unit STEP 2: LOCATE UNIT AND MEASURE SIGNAL STRENGTH (RSSI) First, you will be confirming that Telguard has adequate cellular signal strength. Press the LED/RSSI Mode Toggle button one time, LEDs will now indicate signal strength. Minimum recommended is 3 (3 on solid) with multiple towers in range (LED 1 on solid). Press the LED/RSSI Mode Toggle button a second time to exit RSSI mode. STEP 3: CONFIGURE PANEL ALARMS FOR SOLE PATH CONNECTION Fire panels are typically provided with two Telco connections. Because the TG-7FS provides a single connection, the panel must be set up accordingly. The first method of installation is to configure the panel to disable the second Telco connection. If this is not an option due to panel limitations, it is possible to splice both TIP and RING connections from the panel into the single jack of the Telguard. The TG-7FS is capable of providing dial tone to both Telco connections. STEP 4: PROGRAM, ACTIVATE & TRANSMIT PANEL ALARMS OVER THE CELLULAR RADIO NETWORK Program the TG-7FS for Sole Path communication. You may do this by setting Memory Location 831 to a value of 3, using a butt-set. (See programming guide on reverse). LED 3 will be off when idle, if successful. Next, connect the alarm panel's digital dialer output to Telguard and verify that alarm signals can be reliably sent through Telguard over cellular to the central station digital receiver. A minimum of two alarm signals must be transmitted. (NOTE: THE FIRST ALARM WILL ACTIVATE THE UNIT AT THE TELULAR COMMUNICATION CENTER, IT WILL NOT GO TO THE CENTRAL STATION, ALL SIGNALS AFTER THE FIRST ARE SENT TO THE CENTRAL STATION) STEP 5: CONNECT SUPERVISORY TRIP OUTPUTS Next, you will wire Telguard's supervisory trip outputs to the alarm panel and then test. STEP 6: CONNECT TRIP INPUT (OPTIONAL) Optionally, you can wire the external relay input to the trip input lead and ground, and test. STEP 7: COMPLETE THE INSTALLATION Your last step will be to attach earth ground, and permanently mount the unit. The LED/RSSI mode will reset to normal after 10 minutes. Setup & Programming the Operating Parameters in the Telguard TG-7FS When the Telguard is received from the factory and is powered up for the first time, it is immediately ready for activation, provided the default settings are what you want (note: registration form must be sent to Telular). The STC LED # 2 will flash to indicate any failure conditions. The Mode LED # 3 will be on and the STC 1 and STC 2 relays will be tripped. If changes are required to the default settings, the Telguard can be programmed using a line-mans butt-set connected to T & R Test Points or a POTS phone connected to the panel RJ-45 jack (black connector where the alarm panel is normally connected). TO PROGRAM THE Telguard TG-7FS Put the line-mans butt-set in talk mode or pick up the POTS phone. Dial '', you will hear 2 beeps. Press #, *, this will put the Telguard into a Master Access programming mode, 2 beeps. Enter changes required. The syntax for programming a specific memory location is as follows: MEMORY LOCATION (3-digits), will respond with 2 beeps, then VALUE, will respond with 2 beeps. Then press ', you will hear 2 beeps then hang up. This saves the change and exits the programming mode. Mem Loc. Field Default Value Setting 831 = Telco Primary/Cellular Backup Mode of operation 1 2 = cellular Primary/Telco Backup 3 = cell Only 01 = 4x2 pulse, 40pps 2300 hz 02 = 4x2 pulse, 20pps 2300 hz 03 = 4x2 pulse, lopps 1400 hz 04 = 3x1 pulse, 40pps, 2300 hz 833 cic Reporting Format 09 05 = 3x1 pulse, 20pps, 2300 hz 06 = 3x1 pulse, lopps, 1400 hz 07 = Radionics lie or Illa2 08 = contact ID 09 = Auto Format Detect 11 = SIA2 (300 Baud) 12 = DMP Enter the SUM TOTAL of the events that you wish to trip the STC relay by STC1 Trip Output 04 ADDING the corresponding values: 850 Reporting (LFC only) 00 = Not Used 04 = LFC 32 = DTF Normally Open 01 =AC Failure 08 = NSC 63 = ALL 02 = Low Battery 16 = RFC Enter the SUM TOTAL of the events that you wish to trip the STC relay by STC2 Trip Output 59 ADDING the corresponding values: 851 Reporting (all except LFC) 00 = Not Used 04 = LFC 32 = DTF Normally Closed 01 = AC Failure 08 = NSC 63 = ALL 02 Low Battery 16=RFC 1=30 seconds 4=10 minutes 7=45 minutes 852 STC Trip Delay for NSC 2 (60 sec) 2=60 seconds 5=20 minutes 8=60 minutes 3=3 minutes 6=30 minutes 9=24 hours 0 = terminate STC history display mode 858 STC History N/A I = start STC history display mode 2 = clear STC history 861 CFC Number of Events 0 (disabled) 0 = disabled 2 = 4 attempts 1 = 2 attempts 3 = 8 attempts 862 CFC Between Events 1 (30 sec) 1 = 30 seconds 3 = 70 seconds 5 = 90 seconds 2 = 60 seconds 4 = 80 seconds 6 = 99 seconds 868 PPF Delay 0 (disabled) 0 = disabled, 1 = 10 seconds, 2=20 seconds, 15=150 seconds 872 AC Failure Delay 02 (2 hours) 0-24 hours 873 Trip input Reporting 0 (no report) 0 = no report 1 = report trip 874 Trip Input Restoral Reporting 0 (no report) 0 = no report 1 = report restoral 875 Trip Input Swinger Function 0 (disabled) 0 = swinger function disabled = swinger function enabled 899 Factory Default Unit NOTE: SPECIAL LED INDICATIONS DURING ACTIVATION If the Telguard fails to confirm activation it will be displayed on the LEDS: System Status LEDs Activation Indications LEDS 1-5 FLASHING FAILED ACTIVATION - SIGNAL TOO WEAK LED #1 & LED #4 FLASHING ACTIVATION ERROR - CALL TECH SUPPORT LED #1 ON ACTIVATION SUCCESSFUL LED #1 Off NOT ACTIVATED NEED TO CONNECT PANEL AND TRIP ZONE On either a FAILED ACTIVATION or ACTIVATION ERROR, the unit MUST BE RESET BY PRESSING THE RSSI BUTTON TWICE. The activation message MUST BE RESENT or the TELGUARD will not transmit signals through the cellular network. Repeat step 4 above. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-1402:0110) Page 1 of I CATEGORY: (Fire Alarm Control Unit Accessories/Misc. Devicesi LISTEE: ([ULAR CORP.,)3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju©telular.com DESIGN: *TG7LVAOI *TG7LVFOI and TG-KlTigital cellular communicator odels [M_od_e_ m ls_ .~W *_T_G_7LV001, are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04072017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an 1/ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (2V7Ah) DISCHARGE CHARACTERISTICS AT 25 C(77 F) UUIIIIlUUIIuuIIIII•U E-.' i Nam: W-111-ft M !UuIIII•U - • UiiHiIRUiLuuuiii•U. • ..iuiiiu.u•iiu•uiiiuuu•u. uuuEliHrIuI••IIuhlI 2 3 5 10 00 30 60 0 3 5 ID 20 30 CHMOED Discharge Time 120 006 40 104 01 POE R KINGDOM(Sealed Lead-Acid Batted esD Specifications Nominal Voltage 12V Rated Capacity 7Ah Dimensions Total Height 3.98 inches (101mm) Height 3.74 inches (95mm) Length 5.94 inches (151mm) Width 2.56 inches (65mm) Approximate Weight 4.52 lbs. (2.05kg) Characteristic Capacity 77°F(25°C) 20h rate 7.00Ah 10h rate 6.50Ah 5h rate 5.95Ah lh rate 4.20Ah 15 mill rate 3.15Ah Internal Resistance Full Charged Battery 77°F(250C) 25m0 Capacity Affected by Temperature (20h rate) 104°F(400C) 102% 770F(25°C) 100% 320F(0°C) 85% 50F(-150C) 65% Self-Discharge 680F(200C) (Capacity after) 3 month storage 90% 6 month storage 80% 12 month storage 60% Max. Discharge Current_77°F(25°C) 105A(5s) Terminal T2 TI J2 Charge (Constant Voltage,250C) Cycle I 14.5.- 14.9V(-24mV/°C) I max. current: 2.1 A Float 13.6-.-13.8V(-18mV/°C) Constant Current Dincharp Characteristics (A.25C Chargeing Time (h) Cycle service life 12( 100 7 so 10 00101020 P40120% 0605a,200ep1 50% d,p4030 40 200 400 600 600 000 120D Life (cycle) F.V/TIMIE 5min 10min 15min 30min 60min 3h 5h lOb 20h 9.60V 27.0 18.0 14.0 8.40 4.70 1.73 1.15 0.71 0.37 10.2V 25.7 17.1 13.4 8.06 4.55 1.70 1.13 0.70 0.36 10.5V 24.2 16.1 12.7 7.66 4.35 1.65 1.10 0.68 0.35 Constant Current D achare Characteristics (Watt.2512 F.V/TIME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 301 203 160 94.2 54.4 20.6 13.8 8.52 4.43 10.2V 287 191 153 90.4 52.7 20.2 13.6 8.40 4. 33 10.5V 270 180 145 86.0 50.4 19.6 13.2 8.17 4.21 (E)POTTER The Symbol of Protection U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50mm thru 200mm). LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic re- tard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die- cast housing. The cover is held in place with two tamper resis- tant screws which require a special key for removal. A field in- stallable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. VSR-F VANE TYPE WATERFLOW) LARM SWITCH WITH RETARD UL, ULCandCSFM Listed, FM and LPCBApproved, NYMEA Accepted, CE Marked Service Pressure: Up to 450 PSI (31 BAR) Minimum Flow Rate forAlarm: 10 GPM (38 LPM) Maximum Surge: 18 FPS (5,5 m/s) ContactRatings: Two sets of SPDT (Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA4/1P54 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/1 20°F, 4,5°C/49°C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40, sizes 2" thru 8' BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-1 3D Residential occupancy up to four stories NFPA-1 3R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be in- stalled within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a dis- tance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. (68 n-m) of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8800001 - REV W PAGE 1 OF 2 MFG. #5400761 - 7/02 FIG. 2 DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL 5OFT.—LBS (68 n—m) OF TORQUE MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW APPROX. RETARD SETTINGS (IN SECS.) o O A 10-25 B 20-40 C 35-55 D 50-70 E 60-90 OPTIONAL TAMPER SWITCH RETARD ADJUSTMENT: TO CHANGE TIME TURN KNOB (EITHER DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS, A "B" SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO "8". TO INSTALL, DRILL HOLE AS INDICATED: PIPE SIZE HOLE SIZE to 2 1/2" 1 1/4" +1/8" —1/16" (50mm to 65mm) (33mm ±2mm) to 8" 2" ±1/8" (80mm to 200mm) 50mm ±2mm) Cover Tamper (with cover in place) DIRECTION OF WATERFLOW C NO NC (wHI) (RED) (BLK) ITT. IM1WI63 DWG. #761-30 FIG.4 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. DWG. 1761-4 (E)POTTER The Symbol of Protection VSR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FIG. I SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL 1060 10 OUTGOOG ." DWG. 0923-3 CAUTION: An uninsulated section of a single conductor should not be looped around the termi- nal and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG. 3 TYPICAL ELECTRICAL CONNECTIONS NOTES: The Model VSR-F has two switches, one can be used to 2 SETS OF operate a central station, pro- NORMALLY OPEN CONTACTS CLOSE ON ALARM wATERn.OR ZONE EOLR FROM I ON FIRE PANEL RE PANEL I prietary or remote signaling f-i1—\ I unit, while the other contact is I II used to operate a local audible or visual annunciator, _______ A condition of LPC Approval of POSITIVE DC this product is that the electri- THE RAID MAI6IOTITS ON THE SWITCH ARE FOR OR AC BELL cal entry must be sealed to AN ALARM CONDITION. THE CONTACTS ARE REVERSED NEGATIVE DC _____________________ OR NEUTRAL AC exclude moisture. "EN THE REACE IT IN O" P61-2 SHE NORMAL CONDITiON. For supervised circuits see Switch Terminal Connec- tions" drawing and caution note (Fig. 1). APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the lire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT. #8800001 - REV W PAGE 2 OF 2 MEG. #5400761 -7102 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. (7770-0328:0001) Page 1 of I CATEGORY: (7770 -- VALVES/SWITCHES) LISTEE: [Potter Electric SigCo1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Vane and pressure type water flow alarm switches listed below. Refer to listee's data sheet for detailed product description and operational considerations. Vane Types: VSR-CF VSR-D (y-F) VSR-SF VSR-FE-2 VS-SP VS-F VSR-SFG VSR-SFT VSG VSR VSR-S VSR-C VSR-ST VSR-SG Pressure Type: WFS-B WFSR-C WFSPD-B PSIO PS- bA PS-100A WFSR-F PSIOO INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL or FM label. APPROVAL: Listed as waterfiow alarm switches for use with fire sprinkler systems. Vane models may be used in wet pipe systems; pressure models may be used in wet or dry systems. Model VSR-CF is for use on K, L or M copper pipe (2", 2-1/2", 3", 4") and listed CPVC pipe (2", 2-1/2", 3"). Model VSR-SF for use on 1", 1-1/4", 1-1/2" and *2 steel, copper or listed plastic pipe. Model VSG is for low flow rate. Model VSR-SFG and VSR-SFT are for use on 1", 1-1/4",1-1/2" and *2 plastic pipe. Models VS-F, VSR-F, VSR-FE and VSR-FE-2 is for use on 2', 2-1/2", 3", 3-1/2", 4", 5', 6', 8' and 10" pipe. *Model VSR is for use on steel pipe sizes from 2' through 8". Vane type switches may be used outdoors when the outdoor temperature never falls below 40oF. Rev*5172007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftv operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (Listing Expires) tJune 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER The Symbol of Protection '3 I OSYSU-1 Stock No. 1010106 OSYSU-2 Stock No. 1010206 GENERAL INFORMATION The OSYSU is used to monitor the open position of an OS & Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, con- taining two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS & Y valves ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as small as 1/2" (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or additional cover OSYSU-1, -2 OUTSIDE SCREW AND YOKE VALVE (SUPERVISORY SWITCH)- UL and CSFM Listed, FM Approved, NYMEA Accepted, CE Marked Dimensions: 6.19"L X 2.25"WX 5.88"H 15,7cm LX 5,7cm W 14,6cm H Weight: 2 lbs. (0,9 kg.) Enclosure: Cover - Die-Cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: NEMA 4 and NEMA 6P Enclosure (1P67) when used with appropriate watertight conduit fittings. Indoor or Outdoor use (Not for use in hazardous locations. See bulletin no. 5400705 OSYS-U-EX for hazardous locations.) Temperature Range: -40°F to 140°F (-40°C to 60°C) Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use: Automatic Sprinkler NFPA-1 3 One or two family dwelling NFPA-1 3D Residential occupancy up to four stories NFPA-1 3R National Fire Alarm Code NFPA-72 screws and hex keys are available. See ordering informa- tion on page 4. OPTIONAL COVER TAMPER SWITCH A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTING The OSYSU and its associated protective monitoring sys- tem should be inspected and tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Potter Electric Signal company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8820004 - REV P PAGE 1 OF 4 12101 (E)POTTER The Symbol of Protection OSYSU-11 -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. I SMALL VALVE INSTALLATION - 1/2" THRU 2 1/2" (12,5mm THRU 63,5mm) SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2' TO 12" OS & Y VALVES. THEY WILL MOUNT ON SOME VALVES AS SMALL AS 1/2" (12,5MM). J-HOOKS MAY BE REQUIRED ON VALVES WITH LIMITED CLEARANCE. CLAMP BAR CARRIAGE BC SLOTTED MOUNTING HOLES MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET BRACKET DWG. #979-3 SMALL VALVE INSTALLATION Remove and discard "C" washer and roller from the trip rod. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non- threaded portion of the valve stem. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the 1" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. Mark the valve stem at the center of the trip rod. Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark on the valve stem utilizing a 3/16" (4,8mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 1) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate when the trip rod moves out of the groove. Tighten the adjustment screws and all mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 2 OF 4 12/01 (E)POTTER The Symbol of Protection OSYSU-1, -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" (76mm THRU 300mm) SIZES 3" THRU 12" (76mm THRU 300mm) VALVES BRACKET USE CARRIAGE BOLTS. BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. CARRIAGE BOLTS SLOTTED MOUNTING (2 REQUIRED) HOLES. MAY BE USED ROLLER FOR FINE ADJUSTMENT GROOVE OF SWITCH ON BRACKET. YOKE VALVE STEM II1{I]I] DWG. #979-4 GLAND LARGE VALVE INSTALLATION With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non- threaded portion of the valve stem. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. (9,5mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU loosely with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 2) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: If trip rod length is excessive, loosen the locking 8. screw and remove the trip rod from the trip lever. Using pliers, break off the one 1" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 proce- dure. Tighten the adjustment screws and mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. Mark the valve stem at the center of the trip rod. Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark of the valve stem utilizing a 3/8" NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 3 OF 4 12/01 (E)POTTER The Symbol of Protection OSYSU-1 1 -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG.3 DIMENSIONS FIG.4 PARTS (BLACK) KNOCKOUT FOR ELECTRJCI CONNECTION! RE19 ou ROD II ROD EXTIENDED _-I.J DOC, 1979- SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL 10 G 0010 DWG. 0923-3 TYPICAL ELECTRICAL CONNECTIONS LOCAL CIRCUIT NO. INDICATING TO POWER FOR CO[ N.C. DEVICE INDICATING DEVICE TO SUPERVISORY CIRCUIT END OF OF CONTROL PANEL LINE O N.C. RESISTOR I #979-1 BREAKING EXCESSIVE ROD LENGTH FIG.5 110.1179-7 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervi- sion of the connection in the event that the wire becomes dislodged from under the terminal. ORDERING INFORMATION MODEL DESCRIPTION STOCK NO. OSYSU-1 Outside Screw & Yoke-Supervisory Switch (Single switch) 1010106 OSYSU-2 Outside Screw & Yoke-Supervisory Switch (Double switch) 1010206 -- Cover Screw 5490344 -- Hex Key for Cover Screws and Installation Adjustments 5250062 -- Optional Cover Tamper Switch Kit 0090131 For pressure reducer type valve installation kits (if required) contact valve manufacturer. Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION OPEN VALVE POSITION CLOSED VALVE POSITION coM.Z.O. SW #1 lrl.0 SW #1 cOM. I ,J, N.O.C9M. SW #2 SW #2 KIT DWG. #979-2 PRINTED IN USA MKT. #8820004 - REV P PAGE 4OF4 12101 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7770-0328:0010) Page 1 of I CATEGORY: 0 -- VALVES/SWITCH) LISTEE: (potter Electric Signal Coiö)Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillW@pottersignal.com DESIGN: Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, Ply, tank temperature or water level valves. Refer to listee's data sheet for detailed product description and operational considerations. HLS-B WLS-W PS-120A OSYSU-2 PTS-B (osysu-il) PIVS-B US-S WLS PTS-C RBVS *PS15 WLS-S PS-40A OSYS-B PMS GVS PCVS-1 US-W PCVS-2 PS4O P5120 *PS25 INSTALLATION: In accordance with listee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation and FM or UL label. APPROVAL: Listed as sprinkler system supervisory switches. NOTE: Formerly 7738-0328:010 *Revision 09-07-2016 dc ØTi This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (Listing ExppJ (June 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SECTION2FIRE ALARM CABLE I PART NUMBER AWO CONDUCTOR SHIELDED! OVERALL I UNSHIELDED DIAMETER I CONDUCTOR L_COLOR JACKET COLOR I VOLTAGE RATING WEIGHT (Ibs)ILJnit I MARKINGS TEMP PUT UPS p BLACK, WHITE, WHITE 300v 18.0 ADT 494469 60°C 500 RED, GREEN, LBS 12/C 22 AWG REEL BROWN, BLUE, TYPE FPLP/ ORANGE, YELLOW, CmP VIOLET, GRAY, PINK, TAN BLACK, RED RED 16.0 ADT 493490 75°C 1000 LBS 2/C 18 AWG BOX TYPE FPLP/ CMP (Vt) (UL) 8.0 ADT 493490 500 LBS 2/C18AWG BOX TYPE FPLP/ ,- CMP (Vt) (UL) LIGHT BLUE, 16.0 ADT 493493 60°C 1000 YELLOW LBS 2/C18AWG BOX TYPE FPLP/ ,- CMP () (UL) 8.0 ADT 493493 500 LBS 2/C18AWG BOX TYPE FPLP/ ,.-.. CMP (U!) (UL) !\J I 2.20 DON'T SEE IT? CALL 1-888-423-8947 ORDERS: PHONE 1-888-423-8947, FAX 847-797-3853 !.'1i 2.21 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM b LISTING SERVICE LISTING No. (7161-2075:0100) Page 1 of I CATEGORY: (7161 7 CABLES-FIRE PROTECTIVE SIGNAiI) LISTEE: (Pa Electric CompanylI60Springfield Road, Union, NJ 07083 Contact: Cindy Regner (908) 687-7810 Fax (908) 687-8860 Email: cregnerpaigeelectric.com DESIGN: Types FPL,Pl..and FPLR power limited fire protective signaling cables. Insulation - PVC compound AlphaGary Smokeguard 4010, Synergistics 1349-1028 FRD, 1360-1021-PID, PP, HDPE or LOPE. Shields - (Optional) All metal or Aluminum Polyester tape. Braid - (Optional) All metal. Jacket - PVC compound AlphaGary Smokeguard 11 6920, Gitto Global GA-8705-03, AlphaGary GW2038, Synergistics 1690-1060,1604-1007 FR, 1100-1092 FRD, JAP6IA or 1410-1011 FRO, Solef 31008-0003. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, Type FPL, FPLP or FPLR, rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. NOTE: Formally 7161-1677:100 XLF: 7161-1509:0100 mt 09-09-11 mt Tf This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (Listing Expires) (June 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TELULAR® Meets UL 864 requirements for sole or dual path communications technology Supports virtually all alarm formats for universal panel compatibility Connects to your central station's PSTN or IP receivers Increases your RMR while saving your customers money The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2010 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system, replacing all of the landlines your customers currently dedicate to their master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. Furthermore, each month they will pay you instead of the local telephone company for the communications path. For each landline they replace with aTG-7FS, their monthly communications bill decreases while your RMR increases. Your customer currently has installed... You can replace it with... Customer Your RMR FIRST PATH SECOND PATH FIRST PATH SECOND PATH SAVES* INCREASES* F1TIIisi: nIIui TG-7FS Supervision) (5 min Not Necessary Cellular FITIIisi: TG-7FS Not (Daily Supervision) (5 min Supervision) Necessary Landline S11I.] 0 (5 min Supervision) Necessary *savings based on the estimated monthly cost of a business line compared to the estimated customer charge for monthly cellular monitoring. By being able to signal failures to the central station within five minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations. When installed with multiple communications technologies, such as DACT, it is acceptable to supervise the cellular communication path just once daily. For existing installations, all landlines can be swapped for a single TG-7FS because of the new five minute supervision mode.