Loading...
HomeMy WebLinkAbout5993 AVENIDA ENCINAS; 100; FPC2020-0152; PermitPERMIT REPORT CL7cityrof Carlsbad Print Date: 10/07/2020 Permit No: FPC2020-0152 Job Address: 5993 AVENIDA ENCINAS, # 100, CARLSBAD, CA 92008-4459 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2101701600 Track #: Applied: 08/27/2020 Valuation: $42,975.24 Lot #: Issued: 09/10/2020 Occupancy Group: Project #: Finaled Close Out: 10/07/2020 #of Dwelling Units: Plan #: - Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: BOLT MEDICAL -SPRINKLER TI (10 HEADS) IN NEW CLEAN ROOM Applicant: FPContractor: FIVE STAR FIRE PROTECTION INC FIVE STAR FIRE PROTECTION INC KEN SPADA 74OE LAMBERT RD, # SUITE A 740 E LAM BERT RD, # STE A LA HABRA, CA 90631-9324 LA HABRA, CA 90631-6180 (562) 690-6500 (562) 690-6500 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1760-602-8561 f I www.carlsbadca.gov 111 IHydrau1ic Summary I PT;C, 52- Job Numbet: 1 Reoort DescriOtion: BOOTH #2 Job Job Number 1 Design Engineer TERRY HODGDEN Job Name: BOLT MEDICAL State Cerfificaflon/License Number 827637 C-16 Address 1 5993 AVENIDA ENCINAS AJ1J CARLSBAD FIRE DEPARTMENT Address 2 CARLSBADr CA 92008 Job Site/Building 5993 AVENIDA ENCINAS Address 3 Drawing Name BOLT MEDICAL SITE1 cad System - Remote Area(s) Most Demanding Sprinkler Date 5.6 K-Factor 26.00 at 21.556 Occupancy Ordinary Group II Job Suttlu Hose Allowance At Source 0.00 Density 0.200gpm/ft2 Area of App/curiae 1500.00ft2 (Actual 884.93ft2) Additional Hose Supplies Node Flow(ap Number Of Sprinklers Calculated In I2AflAdf2 m) Coverage Per Sprinkler AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area 281 .73ga1 Total Hose Streams 0.00 System Flow Demand 263.58 Total Water Required (Including Hosepllowance) 263.58 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 16.64 between nodes 8 and 39 Maximum Velocity Under Ground Volume capacity of FArt Pipes Volume capacity at Dry Pipes Supplies Node Name Hose Flow (gpm) Static (psi) Residual ,_. (psi) Flow (gpm) Available ,- Total Demand (psi) — (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 1 98.000 76.740 I 339.53 8.4691 263.58 62.552 22.139 Contractor Contracter Number 21 Contact Name TERRY I-IODGDEN Contact This ENG Name of Cc tractor FIVE STAR FIRE PROTECTION, INC. Phone (562)690-6500 Extension Address I 740 E. LAMBERT ROAD FAX (562)690-6553 Address 2 LA HABRAr CA 90631 E.marl FIVESTARTWH@YAHOO.COM Address 3 Web-Site ,©M.E.P.CAD, Inc. AutoSPRlNK®12v12.0.61.0 8/17/2020 7:22:24AM Page 1 111 fHydraulic Graph I Job Number: 1 Report Description: BOOTH #2 Water Supply at Node I 100 - Static Pressure 98.000 90— Static Pressure 88.200 (90%) 80— - 39\53@76.740 70— - —j039.53@ 69.066 60 ~\ 52 — CL 50— U) \ \\ System dem and curve 30 —: 20 10— 0 L 111111111 _________ 11111111 III 111111 ioo 200 300 400 500 600 700 800 900 1000 Water flow, gpm Hydraulic Graph Water Supply at Node 1 Static: Pre sure 98.000 Residual; Pressure 76.740 @ 339.53 Available Pressure at Time of Test 84.691 @ 263.58 System Demand 62.552 @ 263.58 System Demand (including slate AeowenSe at Seuma) 62.552 @ 263.58 . © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 8/17/2020 7:22:26AM Page 2 1Summay Of Outfiowing Devices I Job Number: 1 Report Description: BOOTH #2 Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 201 27.22 26.00 5.6 23.629 Sprinkler 202 27.12 26.00 5.6 23.455 Sprinkler 203 26.36 26.00 5.6 22.161 Sprinkler 204 26.27 26.00 5.6 22.013 Sprinkler 205 26.09 26.00 5.6 21.713 Sprinkler 206 26.01 26.00 5.6 21.571 Sprinkler 207 26.09 26.00 5.6 21.698 c Sprinkler 208 26.00 26.00 5.6 21.556 Sprinkler 209 26.18 26.00 5.6 21.851 Sprinkler 210 1 26.24 1 26.00 1 5.6 1 21.951 1 c Most Demanding Sprinkler Data , 0 M.E.P.CAD, Inc. AutoSPRlNK® 12 02.0.61.0 8/17/2020 7:22:29AM Page 3 jNode Analysis I Job Number: 1 Report Description: BOOTH #2 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 108 2470 P0(7-5%) 36.509 109 24-6 E(3'-8Y2) 36.096 110 24-0 P0(7-5%) 37.227 111 24-6 E(3'-8%) 36.818 112 24-0 P0(7-5%) 38.073 113 24-6 E(3'-8%) 37.637 114 24-0 P0(7-5%) 39.065 115 24-6 E(3'-81/2) 38.574 116 24-0 P0(7-5%) 40.238 117 24-6 E(3'-81/2) 39.659 118 24-0 T(16'-5%) 42.961 119 24-0 P0(7-5%) 42.894 120 24-6 E(3'-8%) 42.051 122 24-0 E(8-2%) 45.704 123 24-0 E(8-2%) 47.995 1 0-0 S 62.552 263.58 201 9-0 Spr(-23.629), fd(24'-O) 23.629 27.22 202 9-0 Spr(-23.455), fd(24'-O) 23.455 27.12 203 9-0 Spr(-22.161), fd(24-0) 22.161 26.36 204 9-0 Spr(-22.013), fd(24'-O) 22.013 26.27 205 9-0 Spr(-21.713), fd(24'-O) 21.713 26.09 206 9-0 Spr(-21.571), fd(24'-O) 21.571 26.01 207 9-0 Spr(-21 .698), fd(24'-O) 21.698 26.09 208 9-0 Spr(-21 .556), fd(24'-O) 21.556 26.00 209 9-0 Spr(-21.851), fd(24-0) 21.851 26.18 210 9-0 Spr(-21.951), fd(24'-O) 21.951 26.24 3 24-0 P0(12-3%) 32.305 4 24-6 E(3'-8%) 32.188 5 24-0 P0(12-3%) 32.189 6 24-6 E(3'-8%) 32.077 7 24-0 P0(7-51/4) 31.913 8 24-6 E(3'-81/2) 27.050 9 24-0 P0(7-5%) 32.105 10 24-6 E(3'-81/2) 27.265 11 24-0 P0(7-51/4) 33.377 12 24-6 E(3'-8%) 33.392 13 24-0 P0(7-51/4) 34.366 14 24-6 E(3'-81/2) 34.345 15 24-0 P0(7-5%) 35.125 16 24-6 E(3'-8%) 35.101 17 24-0 P0(7-51/.) 35.685 18 24-6 E(3'-8%) 35.687 19 24-0 P0(7-5%) 36.063 20 24-6 E(3-8%) 36.121 21 24-0 P0(7-51/4) 36.275 22 24-6 E(3'-8%) 36.421 23 24-0 P0(12-3%) 36.444 24 24-6 E(3'-8Y2) 36.454 39 24-6 P0(5-0) 26.924 42 24-6 P0(5-0) 27.139 45 24-6 P0(5-0) 24.879 48 24-6 P0(5-0) 25.104 59 24-6 P0(5-0) 24.254 62 24-6 P0(5-0) 24.480 75 24-6 P0(5-0) 24.233 78 24-6 P0(5-0) 24.458 89 24-6 P0(5-0) 24.664 92 24-6 P0(5-0) 24.446 98 24-0 P0(7-51/.) 35.159 99 24-6 E(3'-81/2) 34.665 100 24-0 P0(7-5%) 35.172 101 24-6 E(3-81/2) 34.665 , © M.E.P.CAD, Inc. gilAutoSPRINKO 12 02.0.61.0 8/17/2020 7:22:31AM Page 4 Node Analysis I Job Number: 1 Report Description: BOOTH #2 Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 102 24-0 P0(7-5%) 35.218 103 24-6 E(3-81/2) 33.422 104 24-0 P0(7-5%) 35.430 105 24-6 E(3-81,4) 33.637 106 24-0 P0(7-5%) 35.910 107 24-6 E(3-81/2) 35.461 ,© M.E.P.CAD, Inc. AutoSPRINK® 12 02.0.61.0 8/17/2020 7:22:31AM Page 5 ~111111ydraulic Analysis I Job Number: 1 Report Description: BOOTH #2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary eb •••" Route 1 ..... AO 1.0490 26.00 9.65 120 0.211435 14-6 Pt 9.622 208 78 9-0 24-6 26.00 5.6 21.556 24.458 Sprinkler, E(2'-O), P0(5-0), fd(24'-O) 31-0 45-6 Pe -6.720 Pv FM 1.4420 20.96 4.12 120 0.030122 6-10 Pt 0.206 78 89 24-6 24-6 24.458 24.664 6-10 Pe Pv FM 1.4420 47.19 9.27 120 0.135256 66-4 Pt 8.973 89 105 24-6 24-6 26.24 24.664 33.637 Flow (q) from Route 6 66-4 Pe Pv RN 1.4420 47.19 9.27 120 0.135256 0-6 Pt 1.575 105 104 24-6 24-0 33.637 35.430 E(3-8%) P0(7-5%) 11-1% 11-7% Pe Pv 0.217 FR 2.6350 131.81 7.75 120 0.048011 10-0 Pt 0.480 104 106 24-0 24-0 84.62 35.430 35.910 Flow (q) from Route 3 10-0 Pe Pv FR 2.6350 148.56 8.74 120 0.059903 10-0 Pt 0.599 106 108 24-0 24-0 16.75 35.910 36.509 Flow (q) from Route 15 10-0 Pe Pv FR 2.6350 163.86 9.64 120 0.071814 10-0 Pt 0.718 108 110 24-0 24-0 15.30 36.509 37.227 Flow (q) from Route 16 10-0 Pe Pv FR 2.6350 179.00 10.53 120 0.084570 10-0 Pt 0.846 110 112 24-0 24-0 15.14 37.227 38.073 Flow (q) from Route 17 10-0 Pe Pv FR 2.6350 195.22 11.49 120 0.099290 10-0 Pt 0.993 112 114 24-0 24-0 16.22 38.073 39.065 Flow (q) from Route 18 10-0 Pe Pv FR 2.6350 213.58 12.57 120 0.117252 10-0 Pt 1.173 114 116 24-0 24-0 18.36 39.065 40.238 Flow (q) from Route 2 10-0 Pe Pv FR 2.6350 234.91 13.82 120 0.139833 3-0 Pt 2.723 116 118 24-0 24-0 21.33 40.238 42.961 Flow (q) from Route 11 T(16'-5%) 16-5% 19-5% Pe Pv FR 2.6350 263.58 15.51 120 0.173040 77h/2 Pt 2.743 118 122 24-0 24-0 28.68 42.961 45.704 Flow (q) from Route 12 . E(8'-2%) 8-2% 15-10% Pe Pv FM 2.6350 263.58 15.51 120 0.173040 5-0 Pt 2.291 122 123 24-0 24-0 45.704 47.995 E(8'-2%) 8-2% 13-2% Pe Pv FR 2.6350 263.58 15.51 120 0.173040 24-0 Pt 4.153 123 1 24-0 0-0 47.995 62.552 Water Supply 24-0 Pe 1 Pv 10.405 0.00 Hose Allowance At Source 1 263.58 Route AO 1.0490 26.01 9.66 120 0.211574 14-6 Pt 9.628 206 62 9-0 24-6 26.01 5.6 21.571 24.480 Sprinkler, E(2'-O), P0(5-0), fd(24-0) 31-0 45-6 Pe -6.720 Pv FM 1.4420 31.05 6.10 120 0.062361 10-0 Pt 0.624 62 48 24-6 24-6 5.04 24.480 25.104 Flow (q) from Route 20 10-0 Pe Pv FM 1.4420 57.33 11.26 120 0.193852 10-6 Pt 2.035 48 42 24-6 24-6 26.27 25.104 27.139 Flow (q) from Route 7 10-6 Pe Pv FM 1.4420 84.45 16.59 120 0.396911 0-3% Pt 0.126 42 10 24-6 24-6 27.12 27.139 27.265 Flow (q) from Route 9 0-3% Pe Pv RN 1.4420 84.45 16.59 120 0.396911 0-6 Pt 4.623 10 9 24-6 24-0 27.265 32.105 E(3-81,4) P0(7-51/4) 11-1% 11-7% Pe Pv 0.217 FR 2.1570 131.77 11.57 120 0.127202 10-0 Pt 1.272 9 11 24-0 24-0 47.33 32.105 33.377 Flow (q) from Route 4 10-0 Pe Pv FR 2.1570 115.03 10.10 120 0.098919 10-0 Pt 0.989 11 13 24-0 24-0 33.377 34.366 10-0 Pe Pv FR 2.1570 99.73 8.76 120 0.075962 10-0 Pt 0.760 13 15 24-0 24-0 34.366 35.125 1 10-0 Pe IPV ©M.E.P.CAD, Inc. 4AutoSPRlNK®12v12.0.61.0 8/17/2020 7:22:33AM Page 6 I Hydraulic Analysis 1 Job Number 1 Report _Description: _BOOTH #2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary FR 2.1570 84.59 7.43 120 0.056015 10-0 Pt 0.560 15 17 24-0 24-0 35.125 35.685 10-0 Pe Pv FR 2.1570 68.37 6.00 120 0.037780 10-0 Pt 0.378 17 19 24-0 24-0 35.685 36.063 . 10-0 Pe Pv RN 1.4420 18.36 3.61 120 0.023584 0-6 Pt 0.275 19 20 24-0 24-6 36.063 36.121 P0(7-5%) E(3-8%) 11-1% 11-7% Pe -0.217 Pv FM 1.4420 18.36 3.61 120 0.023584 104-0 Pt 2.453 20 115 24-6 24-6 36.121 38.574 104-0 Pe Pv RN 1.4420 18.36 3.61 120 0.023584 0-6 Pt 0.275 115 114 24-6 24-0 38.574 39.065 E(3'-8%) P0(7-5%) 1 11-1% 11-7% lPv Pe 0.217 =. ..... Route 3 ..... AO 1.0490 26.09 9.68 120 0.212720 12-6 Pt 9.255 207 75 91-0 24-6 26.09 5.6 21.698 24.233 Sprinkler, E(2'-O), P0(5-0), fd(24'-O) 31-0 43-6 Pe -6.720 Pv FM 1.4420 21.08 4.14 120 0.030463 7-0 Pt 0.213 75 92 24-6 24-6 24.233 24.446 7-0 Pe Pv FM 1.4420 47.26 9.28 120 0.135615 66-2% Pt 8.975 92 103 24-6 24-6 26.18 24.446 33.422 Flow (q) from Route 5 66-2% Pe Pv RN 1.4420 47.26 9.28 120 0.135615 0-6 Pt 1.580 103 102 24-6 24-0 33.422 35.218 E(3'-8%) P0(7-5%) 11-1% 11-7% jPv Pe 0.217 FR 2.6350 84.62 4.98 120 0.021146 10-0 Pt 0.211 102 104 24-0 24-0 37.35 35.218 35.430 Flow (q) from Route 13 10-0 Pe Pv eo ..... Route 4 ..... AO 1.0490 26.09 9.69 120 0.212859 12-6 Pt 9.261 205 59 9-0 24-6 26.09 5.6 21.713 24.254 Sprinkler, E(2'-O), P0(5-U), fd(24'-O) 31-0 43'-6 Pe -6.720 Pv FM 1.4420 31.10 6.11 120 0.062519 10,-U Pt 0.625 59 45 24'-6 24-6 5.00 24.254 24.879 Flow (q) from Route 19 10,-0 Pe Pv FM 1.4420 57.46 11.29 120 0.194674 10-6 Pt 2.044 45 39 24'-6 24-6 26.36 24.879 26.924 Flow (q) from Route 8 10-6 Pe Pv FM 1.4420 84.68 16.64 120 0.398926 0-3% Pt 0.126 39 8 24'-6 24-6 27.22 26.924 27.050 Flow (q) from Route 10 0-3% Pe Pv RN 1.4420 84.68 16.64 120 0.398926 0-6 Pt 4.647 8 7 24-6 24'-U 27.050 31.913 E(3-8%) P0(7-51/.) 11-1% 11-7% Pe 0.217 1. Pv FR 2.1570 47.33 4.16 120 0.019131 10,-0 1 Pt 0.191 7 9 24-0 24'-0 31.913 32.105 10,-0 Pe 1PV Route 5 ..... AO 1.0490 26.18 9.72 120 0.214107 12-6 Pt 9.315 209 92 91-0 24-6 26.18 5.6 21.851 24.446 Sprinkler, E(2-U), P0(5-U), fd(24'-O) 31-0 43-6 Pe -6.720 Pv Route 6 ..... AO 1.0490 26.24 9.74 120 0.215018 12-10% Pt 9.433 210 89 91-0 24'-6 26.24 5.6 21.951 24.664 Sprinkler, E(2'-U), P0(5-U), fd(24-0) 31-0 43-10% Pe -6.720 Pv Route 7 ..... AO 1.0490 26.27 9.75 120 0.215576 14-6 Pt 9.810 204 48 9-0 24-6 26.27 5.6 22.013 25.104 Sprinkler, E(2'-U), P0(5-0), fd(24-0) 31-0 45-6 Pe -6.720 Pv =. ..... Route 8••••• AO 1.0490 26.36 9.79 120 0.216922 12-6 Pt 9.438 203 45 91-0 24'-6 26.36 5.6 22.161 24.879 Sprinkler, E(2'-U), P0(5-0), fd(24'-O) 31-0 43-6 Pe -6.720 Pv .Route 9 ..... AO 1.0490 27.12 10.07 120 0.228610 14-6 Pt 10.403 202 42 91-0 24'-6 27.12 5.6 23.455 27.139 Sprinkler, E(2'-U), P0(5-U), fd(24'-O) 31-0 45-6 Pe -6.720 JPv =. ..... Route 10 ..... (,©M.E.P.CAD, Inc. AutoSPRINK01202.0.61.0 8/17/2020 7:22:33AM Page 7 Hydraulic Analysis I Job Number: 1 Report _Description: _BOOTH #2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Elevation Discharge K-Factor Pt Pn Fittings Upstream AO 1.0490 27.22 10.11 120 0.230176 12-6 31-0 43-6 N 10.014 Pe -6.720 Pv 201 9-0 27.22 5.6 23.629 Sprinkler, 39 24-6 26.924 E(2'-O), P0(5-0), fd(24-0) =. ..... Route 11 FR 2.1570 50.01 4.39 120 0.021184 10-0 10-0 Pt Pe Pv 0.212 19 24-0 36.063 21 24-0 36.275 RN 1.4420 21.33 4.19 120 0.031131 0-6 11-1% 11-7% N Pe Pv 0.363 -0.217 21 24-0 36.275 P0(7-5%) 22 24-6 36.421 E(3-8%) FM 1.4420 21.33 4.19 120 0.031131 104-0 104-0 N Pe Pv 3.238 22 24-6 36.421 117 24-6 39.659 RN 1.4420 21.33 4.19 120 0.031131 0-6 11-1% 11-7% lPv N Pe 0.363 0.217 117 24-6 39.659 E(3'-81/2) 116 24-0 40.238 P0(7-5%) 1 Route 12 • FR 2.1570 28.68 2.52 120 0.007572 10-0 N 0.169 21 23 24-0 24-0 36.275 36.444 P0(12-3%) 12-3% 22-3% Pe Pv RN 1.4420 28.68 5.63 120 0.053812 0-6 N 0.227 23 24 24-0 24-6 3 6. 444 36.454 E(3-81/2) 3-8% 4-2% Pe Pv -0.217 FM 1.4420 28.68 5.63 120 0.053812 104-0 Pt 5.596 24 120 24-6 24-6 36.454 42.051 104-0 Pe Pv RN 1.4420 28.68 5.63 120 0.053812 0-6 N 0.627 120 119 24-6 24-0 42.051 42.894 E(3'-8%) P0(7-5%) 11-1% 11-7% jPv Pe 0.217 FR 2.6350 28.68 1.69 120 0.002857 7-0 N 0.067 119 118 24-0 24-0 42.894 42.961 T(16'-5%) 16-5% 23-5% Pe Pv Route 13. FR 2.1570 37.35 3.28 120 0.012349 10-0 N 0.275 7 5 24-0 24-0 31.913 32.189 P0(12-3%) 12-3% 22-3% Pe Pv RN 1.4420 18.90 3.71 120 0.024885 0-6 N 0.105 5 6 24-0 24-6 32.189 32.077 E(3-8%) 3-8% 4-2% Pe Pv -0.217 FM 1.4420 18.90 3.71 120 0.024885 104-0 N 2.588 6 101 24-6 24-6 32.077 34.665 104-0 Pe Pv RN 1.4420 18.90 3.71 120 0.024885 0-6 N 0.290 101 100 24-6 24-0 34.665 35.172 E(3'-81/2) P0(7-51/,) 11-1% 11-7% Pe Pv 0.217 FR 2.6350 37.35 2.20 120 0.004659 10-0 N 0.047 100 102 24-0 24-0 18.45 35.172 35.218 Flow (q) from Route 14 10,-0 Pe 1 Pv Ga ..... Route 14..... FR 2.1570 18.45 1.62 120 0.003351 10-0 N 0.116 5 3 24-0 24-0 32.189 32.305 P0(12-3%) P0(12-3%) 24-7% 34-7% Pe Pv RN 1.4420 18.45 3.63 120 0.023812 0-6 N 0.100 3 4 24-0 24-6 32.305 32.188 E(3'-81/2) 3-81/2 4-2% Pe Pv -0.217 FM 1.4420 18.45 3.63 120 0.023812 104-0 N 2.476 4 99 24-6 24-6 32.188 34.665 104-0 Pe Pv RN 1.4420 18.45 3.63 120 0.023812 0-6 N 0.277 99 98 24-6 24-0 34.665 35.159 E(3-8%) P0(7-51/4) 11-1% 11-7% Pe jPv 0.217 FR 2.6350 18.45 1.09 120 0.001264 10-0 N 0.013 98 100 24-0 24-0 35.159 35.172 10-0 Pe Pv .Route 15 ..... RN 1.4420 16.75 3.29 120 0.019900 0-6 N 0.232 11 12 24-0 24-6 33.377 33.392 P0(7-51/4) E(3'-8%) 11-1% 11-7% Pe Pv -0.217 FM 1.4420 16.75 3.29 120 0.019900 104-0 N 2.070 12 107 24-6 24-6 33.392 35.461 1 104-0 Pe lPv 1J©M.E.P.CAD, Inc. AutoSPRINK®12v12.0.61.0 8/17/2020 7:22:33AM Page 8 11 IYc1L1c Analysis M I Job Number: 1 Report _Description: _BOOTH #2 Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary RN 1.4420 16.75 3.29 120 0.019900 0-6 N 0.232 107 106 24-6 24-0 35.461 35.910 E(3-81/2) P0(7-5%) 11-1% 11-7% Pe Pv 0.217 ..... Route 16 ..... RN 1.4420 15.30 3.01 120 0.016835 0-6 N 0.196 13 14 24-0 24-6 34.366 34.345 P0(7-5%) E(3-81,4) 11-1% 11-7% Pe Pv -0.217 FM 1.4420 15.30 3.01 120 0.016835 104-0 N 1.751 14 109 24-6 24-6 34.345 36.096 104-0 Pe Pv RN 1.4420 15.30 3.01 120 0.016835 0-6 N 0.196 109 108 24-6 24-0 36.096 36.509 E(3-81/2) P0(7-5%) 11-1% 11-7% Pe Pv 0.217 Go ..... Route 17 ..... RN 1.4420 15.14 2.97 120 0.016509 0-6 N 0.192 15 16 24-0 24-6 35.125 35.101 P0(7-5%) E(3-8%) 11-1% 11-7% Pe -0.217 Pv FM 1.4420 15.14 2.97 120 0.016509 104-0 N 1.717 16 111 24-6 24-6 35.101 36.818 104-0 Pe Pv RN 1.4420 15.14 2.97 120 0.016509 0-6 N 0.192 111 110 24-6 24-0 36.818 37.227 E(3-8Y2) P0(7-51/4) 11-1% 11-7% Pe Pv 0.217 Go ..... Route 18 ..... RN 1.4420 16.22 3.19 120 0.018752 0-6 N 0.218 17 18 24-0 24-6 35.685 35.687 P0(7-5%) E(3-81/2) 11-1% 11-7% Pe Pv -0.217 FM 1.4420 16.22 3.19 120 0.018752 104-0 N 1.950 18 113 24-6 24-6 35.687 37.637 104-0 Pe Pv RN 1.4420 16.22 3.19 120 0.018752 0-6 N 0.218 113 112 24-6 24-0 37.637 38.073 E(3-81/2) P0(7-51/4) 11-1% 11-7% Pe Pv 0.217 Route 19 ..... FM 1.4420 5.00 0.98 120 0.002128 10-0 Pt 0.021 75 59 24-6 24-6 24.233 24.254 10-0 Pe Pv Go ••••• Route 2O••• FM 1.4420 5.04 0.99 120 0.002161 10-0 N 0.022 78 62 24-6 24-6 24.458 24.480 10-0 Pe Pv Equivalent Pipe Lengths of Valves and Fittings (C20 only) I Actual Inside Diameter 4,87 Schedule 40 Steel Pipe Inside Diameter ) = Factor C Value Multiplier Value Of C 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 , © M.E.P.CAD, Inc. AutoSPRINK® 12 02.0.61.0 8/17/2020 7:22:33AM Page 9 IHydraulic Analysis I Job Number: 1 JN1IM repon uescrlpuon: uu I ii z Downstream Elevation Upstream Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary Pipe Type Legend Units Legend Fittings Legend AC Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing ON Drain Discharge gpm BalV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 900 FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DelV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe Pe Pressure due to elevation difference between indicated points E 90° Elbow UG Underground Pv Velocity pressure at a point in a pipe EE 45 Elbow Eel 11% Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PC Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cao J ©M.E.P.CAD, Inc. 41AutoSPRINK@1202.0.61.0 8/17/2020 7:22:33AM Page 10 Pipe Hangers TOLCO Fig. 200 - "Trimline" Adjustable Band Hanger TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining for Copper Tubing TOLCO Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated TOLCO Fig. 200S - "Trimline" Adjustable Band Hanger with Removable Nut (For sizes 1" thru 2") Size Range: c® Fig. 2001/2" (15mm) thru 8' (200mm) pipe A VS 1' Overall Height LISTED APPROVED Material: Steel, Pre-Galvanized Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 1/2" (15mm) thru 2" (50mm) sizes have flared edges for ease of installation on all pipe types and protects CPVC plastic pipe from abrasion. Captured knurled nut design (flared top) on 1" thru 2" sizes keep nut from separating with hanger. Hanger is easily installed around pipe. 1/2" (15mm), 3/4" )20mm), and 21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. For 1/2" (15mm) and 3/4" (20mm) sizes with non-captured knurl nuts order Fig. 200S Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig. Factory Mutual Engineering Approved (FM) (3/4" 120mm1 thru 8" (200mm)). 200-1 to Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 200-2 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) AW , . -. . Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Part number and pipe size CL X . ** Note: For metric hanger rod sizes add the f , . / . , ) I metric rod size to the figure number. Example: 200M8-11/2 or200Mi0-11/2 . . .1 Fig. 200C Fig. 200F Fig. 200 Fig. 200 & Fig. 200S t M8 rod size is not UL Listed or FM Approved 200C-11/2 shown 200E-11/2 shown shown with captured nut shown with 1" thru 2" sizes only non-captured nut Part No.** Pipe Size in. (mm) Rod Size in. mm A in. (mm) B in. (mm) D in. (mm) Max. Rec. Load lbs. (kN) Approx. Wt./100 lbs. (kg) 200 1/2 1/2 (15) W-116 M8t or M10 31/8 (794) 2I1f (667) 111/32 (341) 400 (178) 11 (50) 200-/4 3/4" (20) /8"-16 M8t or MID 31/8" (79.4) 21/2" (63.5) 11/16" (21.0) 400 (1.18) 11 (5.0) 200-1 1 (25) 3/9'-16 M81 or MID 3/u (857) 2/ (667) 1/8 (286) 400 (178) 12 (55) 200-11I4 11/4" (32) /8"-16 M8i or M10 33/4" (94.0) 2/8" (73.0) 1/32" (29.3) 400 (1.78) 13 (5.9) 200-11/2 11/2 (40) 3/8"-16 M18 or M10 37/t (984) 2/8 (730) 1/1€ (302) 400 (178) 14 (64) 200-2 2° 1501 /811-16 M8t or MiD 41/2" (114.3) 3° (76.3) 13/16" (30.2) 400 (1.78) 15 (6.9) 200-21/2 21/2 (65) 3/ 16 MID 5/u (1429) 41/8 (1041) 1J16 (365) 600 (267) 21 (12.3) 200-3 3" (75) /8"-16 MID 5/8" (149.1) 4" (101.6) 11/4" (31.7) 600 (2.67) 29 (13.3) 260-31/2 31/2 (90) 3/o"-16 MID 7/t (1813) 51/4 (1333) 2/it (556) 600 (267) 34 (156) 200-4 4" (100) 3/8 -16 MID 7/8" (187.3) 5" (127.0) 1/8" (34.9) 1000 (4.45) 35 (16.0) 2005 5 (125) 1/2 13 M12 91/8 (2318) 61/4 (1587) 311/32 (849) 1250 (556) 66 (302) 200-6 6" (150) 1/2"13 M12 101/8" (257.2) ON (171.4) 2/32" (56.3) 1250 (5.56) 73 (33.4) 200-8 8 (200) W-113 M12 131/8 (3334) 8I4 (222.2) 3/32 (817) 1250 (556) 136 (623) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 23 Eaton B Center of pipe to top of knurled hanger rod nut. Top of pipe to bottom of hanger rod nut. Fig. - - - . 200-I2 & 20O-/4 -- A fit / Fig. 200-2 /2 to 200-8 Fire Protection FPS-20 i B-LINE SERIES To ~.I, 7, flTe - I FOR Aw -. - - i4 . •• Ik __ -- 1(. .. : 1 p ri EL Ii!1i11 t SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N Victaulic Mechanical-i5 Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently, A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. STYLES 920 AND 920N STYLE 920 CROSS PATENTED MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. "Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183, JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAUU COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV 'A'tauiic' 1L021 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 :itiI.1iUf STYLES 920 AND 920N DIMENSIONS IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections, i .:.. . 2 ½ () a 920N 500 1.50 2.00 2.53 - 1.61 5.35 2.75 3.1 '15 50 3450 38.1 51 64 41 136 70 1.5 ~ (a) a 500 1.50 1,97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 47 136 70 1.5 50N 500 1.50 1.85 2.53 1.61 5.35 2.75 3.0 - 25 3450 38.1 47 64 41 135 70 1.4 1¼ fa) tril 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 l 3.5 1 3.2 3450 44.5 52 70 6 41 111 76 1.7 r 1½ (a) t'? 9CN 500 1,75 2.03 2.75312 1.61 35 3.25 3,6 3.. 4O' 3450 44.5 52 70 79 41 136 83 1.7 1.5 21,12 ½ (a) 5a 92 9ON 500 1,50 2.27 2.74 - 1.82 5.64 2.75 3.0 I - 65 15 3450 36.1 56 70 46 43 70 1.4 % (a) 5a 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 1 (,3) 92 ON 500 1.50 2.05 2.74 1.82 5.64 2.75 2.9 25 1 ¼ 4(a) a °CN 3450 500 ' 38.1 1.75 52 2.30 70 3.00 3.25 45 1.82 143 6.29 70 3.00 1.4 3.5 - 3.2 32 3450 44,5 58 76 83 46 160 76 i 1,7 1 1.5 1½ 1(a) 01 °ON 500 2.00 2.28 3.00 3.25 1.82 6.25 3.25 3.5 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1,6 - 61 x °"ON 300 1.50 2,22 2,75 - 2.25 6.4 3,18 3.9 - '' " 15 2065 381 56 70 57 164 81 1,8 ~ 920N 300 1,50 219 2.75 2.25 6,46 318 3.9 20 2065 38.1 56 70 - 57 164 81 7.8 - (a) 90N7 300 1.50 2.07 2.75 - 2.25 6.46 3.18 3.8 - 25 2065 38.1 33 70 57 164 81 1.7 1¼ (a) a 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3,2 32 3450 445 ,t /n 84 49 160 76 16 , 15 ',q (a) ON 500 200 2.28 300 3.31 192 629 325 5 3.3 40 ' 3450 50.8 58 76 84 49 160 83 1.6 1,5 3 ½ (a) a 920N 500 1,59 2.52 3.05 2.28 6,15 2.75 3,4 80 15 3450 381 64 78 58 156 70 1 1,6 - N (a) a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3,6 20 3450 38,1 63 74 58 156 70 7.6 - a) 929N 500 1.50 2.34. 3.06 - 2.28 6,15 2.75 3.3 25 3450 33' 6' .' 58 156 70 1,6 14(a) 'la 920N 500 1,75 2.s 3.27 , 3.56 2.28 6.15 3.00 3,8 l 3.7 32(h) 3450 44,5 65 8390 58 156 76 '8 1.8 11/2 Ia) fa 920N 500 2.00 2,78 3.50 3.56 2,28 515 3.25 4,1 3.8 40(b) 3450 50.8 71 89 90 58 156 831.9 1,8 2 (a) a 920N 500 2.50 2.75 3.50 158 2.28 6.75 3.88 1 4.9 i 4.6 50 3450 1 63.5 70 89 90 58 172 99 2.3 1 2.1 3½ 2 °20N 500 2.50 3.00 - 3J5 2,44 6,72 3.88 3.8 ' 90 50 3450 63.5 76 95 62 171 99 1,8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). S Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. 4 Female threaded outlets are available to NF1' and SSPJ specifications. @ See page 7 for Fire Pi'ol'cction approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" ciearly on order. (b)For 76.1 mm threaded outlet, specify 2½' BSP'I clearly on order. § Vds approved for lire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. GROOVED OUTLET 1w FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm www.victaulic.com ictaulicr VITAUU0 IS A REGISTERED TRADEMARK OF VIcTAULIC COMPANY. © 2018 VIcTAULIc COMPANY. ALL RIGHTS RESERVED. 11022 REV 0 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 MechanicaT® Bolted ! inch OutF STYLES 920 AND 920N L']ItEiIs]F1 VV GROOVED OUTLET , "wo as is hX11s11 re MIT rip r MIN, FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe also available for use with HDPE pipe Sizes from 2 x ½750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 4 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT' clearly on order. (b(For 76.1 mm threaded outlet, specify 21VY BSPT clearly on order. § \Ids approved for fire protection services LP(:B aporoved for tire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com \4taUlic ____________ vicxeuuc IS REGISTERED TRADEMARK OF VICTALILIC COMPANY. 02018 vICTAuLIc COMPANY. ALL RIGHTS RESERVED. ____ REV-0 11.023 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 STYLES 920 AND 920N DIMENSIONS -- 4_Z__ TABLE CON IINULLS FROM PAGE 500 1 139.7x1t 920N 00 1 378 -3459 50.8 96 114 84 2.09 83 32 23 530 250 37' 450 330 823 388 90 I - - 50 920N 3453 63.5 95 114 - 84 209 99 4.1 / W 5 IS(s) '1 N 530 75 443 5.13 5.13 379 9 5 325 51 48 so X 32 kb) 3450 145 112 30 130 54 " 83 22 22 GROOVED OUTLET I'S (a) 3m 920N 500 200 440 5.73 5.13 3.25 5 5 40 J,1 3453 508 1,12 120 120 05 232 83 24 23 2 530 250 4.38 5.13 5.13 3.79 9 3.88 60 56 SQ 3451 1 635 11 130 130 05 232 99 27 25 F y-i '-z--- -F - 2½ 23 530 775 401 5.13 52 369 1051 .53 83 76 65 9 3433 595 110 1'O 130 94 26 18 38 34 f 0- V 500 275 415 521 3.6.9 1051 4.63 84 76.1 min 9203450 69" 105 - 32 94 267 8 3(a)l 530 350 431 550 5.13 359 1051 531 95 8.4 80 920 3453 e89 110 140 130 04 267 135 45 1 28 20 530 4.50 3.81 5.75 538 3.69 1051 625 101 101 100 92.0 3450 143 07 146 37 94 267 159 46 46 FEMALE THREADED OUTLET ------1 1½(i) ( 730 200 441 513 363 940 325 78 1390 x 40 970N 3453 508 112 130 92 739 83 35 2ta1 530 2.50 138 5 3 3.63 9.40 3.88 80 Provides a direct branch connection at 50 920N 3450 537 11 130 92 '39 99 36 any location where a hole can be cut 76.1 mm 920 500 275 438 550 5.13 363 940 43 05 1 95 in the pipe 3453 69 '1 140 130 92 239 11$ 43 43 20 530 350 431 550 5 3 353 940 53 el 140 A pressure responsive gasket provides 80 3155 889 110 140 130 02 239 135 37 64 the seal OSOmmi 920 ~1,10 450 445 538 353 943 612 100 351 1143 113 127 02 730 155 45 Request Publication 11.03 for 4 920 so 4'03.81 5/. So, 94''6.25 80 Mechanical-T cross assemblies 100 3453 1143 5680 146 92 230 159 8.2 TABLE CONTINUED ON PG. 5 Pressure rated up to 500 psi/3450 kPa Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). on steel pipe; also available for use Available with grooved or female threaded outlet. Specify choice on order. with H DPE pipe Center of run to end of fitting. Sizes from 2 x ½'/SO x 15mm ft Female threaded outlets are available to NP) and BSPT specifications. through 8 x 4/200 x 100mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT' clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2 BSPT clearly on order. § Vds approved for fire protection services _PCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com - - vicrAuLic IS A REGISTERED TRADEMARK OF vicrAuLic COMPANY 02018 VICIAULIC COMPANY, ALL RIGHTS RESERVED. ictaukc 11.02 .4 REV 0 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 1iFii1 1iTEi4!.1iIIiTH t STYLES 920 AND 920N DIMENSIONS y GROOVED OUTLET 1A FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 1103 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15 min through 8 x 4/200 x 100 mm Dimensions ] '-' ) -" ais a' JLLAL = TABLE CONTINUED FROM PAGE 4 w 621 25 500 150 188 920N 3453 391 99 45e llt 3/9 96 934 21 2/5 io 80 36 1/" 503 175 4.43 513920N 379 934 325 84 32 3430 44 5 13 30 96 237 89 38 1/ ) u 503 200 441 913 5.13 379 934 329 84 54 920N 3450 SOc 1'2 30 30 96 237 83 38 24 500 270 438 -20N 513 513 379 991 388 85 sO 50 350 635 ill 0 0 So 237 99 39 2.7 7ulmm 502 275 401 920 513 321 303 1051 '- 63 8.6 76 3450 699 110 30 22 92 267 118 39 34 3 tat I 0, 500 3.50 4.31 920 550 5.13 363 10.51 531 '02 84 83 3453 8c.9 110 40 '30 92 767 135 46 38 4)a)fc 920 500 450 381 575 538 363 1051 625 105 84 130 3253 1143 97 146 37 92 267 159 45 38 8 2a) t 920 son 275 542 619 6.25 4.81 1222 650 11.6 116 " 200 50 3250 699 157 159 122 36 114 5.3 53 25))' 92C 500 2.71 537 619 619 481 2.42 453 11.6 16 65 50 699 157 7 122 316 114 5 3 /6 mr, 1 97 WO 2/5 525 6.25 481 12.42 455 116 3450 699 133 159 122 316 16 53 3p) fu tOO 390 531 920 650 690 481 1242 531 126 116 80 ) 889 135 15 165 122 316 135 97 53 4(a)tu Jo 450 481 ' 675 638 461 122 625 15.3 125 30 3450 '143 122 IC2 '22 36 159 69 27 Center of run to engaged proc end, female threaded outlet only (dimensions approximate) 1' Avaiiable with grooved or lemale threaded outlet Specify choice on order. Center of run to end of fitting 8 venraic' threaded outlets are available :o NP) and 8501 specifications @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed Specify 'BSP F' clearly on order. (b)For 761 mm threaded outlet, specify 21/2 FISPT clearly on order. Vds approved for fire protection services o LPCEI aporeved for lie piu'e toir services 0 Approved for use 2' China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victauliC.com '1 ~, , As tauIic viclAuLic IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2018 VICTAULiC COMPANY. ALL RIGHTS RESERVED. REV-0 11,025 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA 1T fraggel3led for cfarity Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalTe fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°FI+16°C are shown in the table below. Formulas for C5 1K. Values: AP = Where: 0= Flow (GPM) AP = Pressure Drop (psi) 0 = C x JAP CV = Flow Coefficient AP = Q2 Where: O = Flow (m3/hr) V AP = Pressure Drop (Bar) Q = K x JAP K = Flow Coefficient Hazen-Wiliiams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. 1" FireLock Innovative Groove System (IGS) outlet www.victaulic.com tauIic vicruuc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11026 REV ...O CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 iiii1•i ;EI :11..4 i1IJf STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rated _______ Pressures _____ Jz_ 21/2-6 2.875 - 6625 All 10 43 400 400 400 290 232 362 65-150 73.0- 68.3 2755 2755 2755 1999 599 2496 21/2-4 2.8.5 -4.500 All 300 300 300 290 232 362 65-100 73.0- 114.3 2065 2065 2065 1999 1599 2496 21/2 -4 2.875 - All 300 300 300 290 232 362 45 - 100 73.0 - 114.3 - 2065 2065 2065 1999 1599 2496 6 6.625 300 300 25010 290 232 362 150 168.3 2065 2065 1721 1999 1599 2496 0 6.625 34 30,40 300 300 300 290 232 362 50 083 05 20j5 O6i 1999 99 2496 8 8.625 21/2 10,40 - 145 200 219.1 2755----------------- 1000 8 8.625 34 i10 300 250 145 200 219.1 2065 1724 1000 8 8.625 34 30 40 300 300 - 145 - 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-How steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Ho steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation VIC-TAP II HOLE CUTTING TOOL FOR 4 - 87100 - 200 MM CARBON STEEL PIPE Ii The Vic-Tap Il hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/345OkPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5/125mm, 67150mm and 8",'200 mm diameter pipe. The Style 931 comes with a 2½765mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com A—c—ta—ulicr vlcrAuuc ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV-0 11.027 STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included witt ach shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details, NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV UPDATED 1112018 vlcTAuuc s A REGISTERED TRADEMARK OF VlcTAuuc COMPANY. © 2018 VIcTAuLIc COMPANY. ALL RIGHTS RESERVED. X'As-ta -U1 ii e U.02, ,,,L ispenaea ' ? 14 SA MM YS Truss-T Hanger Accessories SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188 and .118. Subsequent testing was done for z-purlin applications in May 1997 using (.037) or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press was completed using (.030) or 22 gauge steel metal deck. Sammys Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins free on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.sammysuperscrew.com. Vibratory Environments For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diamter of fastener. It the table below: Model Root Diameter Hole 1r1Size GST2O .182 1/8" GST25-380 .280 7/32" SWG 20 .182 1/8' SWG 25-380 .280 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local Authority Raving Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.sammysuperscrew.com. M.SOU$ThDAS CWWIARNIDCABAR HARDWARE REDO REDS AS ASOHAW FOR UASHASE CAD Drawings CAD drawings are available and can be downloaded at www.sammysuperscrew.com. Made in the U.S.A. Products Im Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Warranty. Disclaimer of Warranty Proper fastener connection design takes into account where and how fasteners are used. Allowance for special characteristics in materials, differences in materials, differences in types of materials being joined, unique or unusual environmental service or installation conditions and the safety factors required by anticipating normal or short term loading conditions must be considered. Due to possible differences in specifications, applications, and interpretation of results, purchasers and specifiers must make their own evaluation of the products, to determine the suitability of these products for intended use. All warranties of Buildex products, expressed or implied, including the warranties of merchantabilty and fitness for particular purposes are specifically excluded except for the following: Buildex will repair or replace any product which, within twelve months after sale by Buildex or its distributors, is found by Buildex to be defective in material or workmanship - normal wear and tear accepted. This is the sole warranty of Buildex and the sole remedy available to distributor or buyer. Buildex shall not be liable for any injury, loss or damage, direct, indirect, or consequential, arising out of the use of, or the inability to use, any Buildex product Consi Sammys®for Wood . 4 Sammys Swivel Head® for Wood ......................................................................................................4 Sidewinders® for Wood.....................................................................................................................5 Sammys® for Steel............................................................................................................................6 Sammy Swivel Head® for Steel .........................................................................................................6 Sidewinders® for Steel......................................................................................................................7 Sammy X-Press®, Swivel X-Press, and Sidewinder X-Press ........................................................8 SammyX-Press It® Installation Tool..................................................................................................8 Truss-T Hanger® ............................................................................................................................... 9 Sammys® for Concrete...................................................................................................................10 Concrete/Wood Installation Kit.......................................................................................................10 Sidewinders® for Concrete................................................................................................................11 DrywallSammys®/Toggle ................................................................................................................ 12 CeilingScrews.................................................................................................................................12 DektiWPipe Flashing ....................................................................................................................12 SpeedyPole Toofl' .......................................................................................................................... 13 Sammy Saddle w 13 SpotRite Level ..............................................................................................................................13 AssortmentPack............................................................................................................................13 Approvalsand Listings...............................................................................................................14-15 Not less than Wood Flooring 2' nominal width Product Features )1l4 I • No pre-drilling required. Not less than lJoil Quick to install using the Sammy 3' nsminal Nut Driver with an 18V cordless (depth or side thickness 1 (depth or 2-1/2') drill/driver. sf aide vertcalmemberl - • Saves time from traditional Double Sheetoch methods. Ceiling Reduces installation cost. Composite I Truss Made in the U.S.A. Consult truss manufacturer for recommended installation poinL T li - 1/4 8002957 GST /00 1/4 x1'210 (7116' OSB) 25 125 670 1/4 8003957 GST 200 1/4 x 2' 1760 (Fir) 25 125 [ - 1/4 - 8004957 GST 300 114 x"3" 2060 (Fir) 25 - 125 GST 75 I /4 x 3/4 Ply) 25 125 8007957 GST 10 1/4 x1' 210 (7116- OSB) 300 25 125 [ 8008957 GST 20 1l4x2 17 850 1475 25 25 125 Jjx' 8068025 GST 20-OS 1/4x 2 l76u /-r 850 3/8"_8009925 GST 25380 3/8x 2-1/2 2113 (Fr 1500 25 - 316' 8010957 GST 30 1/4x 3' 2060 (Fir) 1500 1475 - - - #14 Black Nut Driver - -- - 3/8' - - 8069925 GST 33 SS 1/4 x 3 2060 (Fir) -- Part# 8113910 3/8 11 8010925 GST 40 1/4 x 4' 2180 (Fr) 25 3/8' 8012925 GST 60 1 /4 x6" 2230 (Err) 25 1- - - - - 1/2 - - 8013925 GST 2 1/432' 1760 (Fir) - - 25 12 j 1/2 8014925 GST 2 5-380 3/8 x 2-1/2' 2113 (Er) 25 / 1/2 8015925 GST 3 1,14 x 3" 2275 (Fi 25 //2' 80/6925 GST4 1/4x4' 2180 (F..1 25 V2 - 8017925 GST6 1/4x6 2220 (Fir) 2512c] #14SWRed Nut Driver Part #8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3 %" x 12 pitch roof. • Reduces installation cost. Allows 17' deflection from vertical. • Made in the U.S.A. 18° 8139957 SH-GST20 1/4 x2' - 1257flr 1475 25 125 125 3/8' 8141957 SH-GST 30 1/4 x 3" 1720 (Fir) 1500 1475 25 125 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the materiel you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information, visit www.sammysuperscrew.com 47 AWL 4#14 Black Nut Driver Part# 8113910 Product Features No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. Made in the U.S.A. Not less than 2' nominal width / (1-1/2') up to 3-'IT pipe; not less than 3' (2-1/7: nomial width 4' & 5' pipe I I Minimum 2-1/2' from bottom for branch lines. Minimum 3' from bottom for mainlines. Exception: This requirement shall not apply to 2' or thicker nailing ships resting on top of steel beams. H IN Floor Joist 1/4 8018957 SWG 100 /4 622 (Fir) - 25 125 /4 8019957 SWG 200 /4 . 1725 (Fir) 25 125 3/8 8020957 SWG 10 1/4 622 (Fir) 300 25 125 l. 3/8 8021957 SWG 20 1/4 1725 (F ( 1050 25 125 3/8 807392. SWG 20-OS 1/4 2 1725 (Fir) 850 25 125_J #14 SW Red , 3/8' 8022925 SWG 25-380 3/8 . 2249 (Fir) 1500 25 125 Nut Driver 3/81, /1123925 SWG 30 1/4 3 1884 (Fir) 25 Part # 8114910 Insert the appropriate nut driver into a 3/8" or 112" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1(2" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow tha above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. ,i R 141 Ei Insert the appropriate nut driver into a 3/8" or 1(2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note; When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot tbs. for maximum pullout in purlln steel. SPECIAL NUT DRIVER SYSTEM: The out crivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing iwo, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. — 0 wir8rg . L . 114 8024957 DSTR 100 * 11420 x1 TEKS 3 1510 (20 ga) .036"-20 ga 3/16" 25 125 1/4 8025957 DST 100 /4-14 xl' TEKS 3 446 (20ga) .036"-20 ga 3/16' 25 125 L.... 1/4 8026957 DST 150 114 14 x 11/2* TEKS 3 970 (16 ga) .66"-20 ga 3/16" 25 - 125 1/4' 8027957 DST 200 1/4-14 x 2' TEKS 3 446 (2 1 036'-20 ga 3/16 25 125 [' 1/4 8030957 TEK 500 12-24'x 1 1/2" TEKS c 3125 ( 187" 3/16" 1/7 25 125] . 3/6" 8038957 DSTR 1 1/4-20 x 1 TEKS 3 1510 ( / 1475 .036"-20 ga 3/16 25 125 - 8037957 DSTR 11/2 • 12-24 x')',1,12 TEKS 5 1510 )316") - 1500 - 1475 060'-16 ga 1/2 25 125 . 3/8' 3/8 8039957 8040957 DSTR 56 DST 10 5/1,6-1,8 1-11/4' TEKS 3 1/4-14 x 1" TEES 3 2200 (20ga) 446 (20 1500 1475 .036'-20 ga 0,36'-20 ga 1/8 3'1S 25 25 125 125 #14 Black 970 (16 ga.) Nut Driver 446 (20 ga) Part #8113910 3/8' 8077925 DST 10-SS 1/4-14 x TEKS 3 970 /16 gal 036"-20 ga 3/16 25 125 3/6" 8041957 DOT 15 1/41431-1/2' TEES 3 446 (20 036'-20 ga 3/15" 25 121] 3/8' 8078925 DST 15-SS 1/4-14 x 1-1/2" TEKS 3 036"-20 ga 3/1 ' 125 3/8 8042957 DST 20 1/4-14 x 2 TEES" 3 (20 ga) 036 20 ga 116 970 )1693) 3/6" 8043957 DST 25 1/4-14 x 21/2 TEKS .036"-20 ga 3/ 25 - 3/6" 8044957 DST 30 1/4-14 x 3" TEES 3 446 (20 '° u36'-20 ga 3116 25 125 3/8' 8045957 DST 516 5/16-18 x 1-1/4' TEKS 3 - 1500)3/16') 1500 125-1/8" 1/8' 25 125 . <> 3/8 8046957 TEE 50 12-24x1- /2 TEES 5 3125 (3/16) 1500 15 187 3116 1/2" 25 1 1/2' 803 925 DST 2 0 /4-14 x 2 TEKS 3 446 (20 88.3/16 1/4' 25 125 1 3925 - DSTR 1,0 1/4-20 xl TEES 3 1510 (20 9a) -- 036"-20 93 3/16 25 125] 1F / - x 1-1/4 TEKS 3 (20 ga) - — .036"-20 ga 1/811,25 125 - 1 8035325 1 14 T E ' .125"-1/8' 1/8" 25 125 lrit 8036925 1EK5.0 1z-z4 x 1-1i TEKS o 31 (3/16*) .187-3/16" 1/2 25 125 #14 SW Red Nut Driver *Includes retaining nut Part# 8114910 _i \TT10 ôr' L pre req,ilred Product Features Made with Teks® self-drilling fasteners - no pre-drilling required. Install into steel range from 22 gauge — 1/2" thicknesses. Saves time from traditional methods. Reduces installation cost. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Product Features Eliminates distortion of threaded rod in • Installs into angled Z-Purlin; Allows \ sloped roof applications, threaded rod to hang plumb. Accommodates 3-1/2 x 12 pitch. • Allows 17* deflection from vertical. 00 4I *Includes 3'5 813 .., 7SH. 1 316) 1 3 115 j 1 'i 125 s retaining nut (Does not comply with ROHS requirements) SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For _the _most ______ date _information, _visit ______________________________________________ — k 7(0 MANNU #14 Black Nut Driver Part # 8113910 Product Features no 1 • Made with Teks® self-drilling fasteners - no pre-drilling required. ling .- preuq %feo • Install into steel range from 22 gauge - 1/2" thicknesses. Saves time from traditional methods. Redu es ation Quickc:install usingl:tSammy Nut Driver with an 18V cordless drill/driver. iLL 1/4" 8047957 SWD 103 1/4-14 x " TEKS 3 1477 (16 ga) 060'16 ga 3/16 25 125 1/4 8049957 SWDR 100 * 1/4-20x 1' TEKS 3 1900 (20ga) 036"-20 ga 3/16 25 125 3/8" 8050957 SWD 10 1/4-14 x TEKS 3 1477 (16 ga) 06318 ga 3/16' 25 125 3/8 8080925 SWD 10-SS /4.14 x 1' TEKS 3 1477 (16 ga) 060-16 ga 3/16 25 125 3/8" 8051957 SWD 15 114-14 xl 1/2" TEKS 3 1477 (16 ga) 060' 16 ga 3/16 25 125 - - 3/8 808 925 SWD 15-SS 1/4-14 x -1/2 TEKS 3 1477 (16 ga) 060"-16 ga 3/16 25 125 3/8" 8052957 SWD 20 1/4-14 x 2" TEKS 3 1477 (16 ga.) - 060'-16 ga 3/16 25 3/8' 8053957 SWD 516 5/16-18 x 1-1/4 TEKS 3 2480 (20 ga) 036'-20 ga 1/8 25 125 #14 SW Red r:< 3/8" - 8055957 SWOR 1 * 1/420 xl TEKS 3 900 (20 ga) - 1500 1475 .036"-20 ga 3/16' 25 025 Nut Driver t.'c8' 3/8 8054957 SWDR 1-1/2 * 2-24 x 1/2' TEKS 5 2375 (3/16) 1500 1475 187'-3/16' /2' 25 125 -111 Part#8114910 <S" 3/8 8056957 SWDR 516 * 5/16-18 xl 1/4"TEI/S 3 2480 (2004) 1500 1475 036 20ga - uS 25 125 - 3/8" 8057957 SWT 15 12-24 x 1-1/2" TEKS 5 237513/16") .187"-3/16 1/2 25 125 .Includes retaining nut Performance Data - Steel OrI Gauge No. 26 24 22 20 18 16 14 12 3116" 114" Nominal Decimal Equivalent .018 .024 1 .030 1 .036 .048 .060 .075 .105 .188 .250 Fastener Steel Gauge (lbs.) Model Dia. Pt. 20 18 16 14 12 3116 114 DST 1/4 #3 446 613 970 1145 1544 3190 DST516 5/16 #3 457 568 1209 1712 2422 TEK50 #12 #5 487 699 913 1527 3270 3593 DSTR 1-112" #12 1 3270 3593 DSTRI" 1/4 #3 1510 DSTR 516 5/16 #3 2200 Fastener _- Steel Gauge (lbs.) Model Dia. Pt. 20 18 16 14 12 3116 114 SWD 1/4 #3 1477 SWDRI.112" #12 #5 2375 SWDRI" 1/4 #3 1900 1900 SWDR 516 5/16 #3 2480 2480 SPECIAL NUT DRIVER SYSTEM The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver conies into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. (SXP) Patent Pending for extreme varaflt roof ptt oes No retaining nut required. Provides design flexibility. The Sammy X-Press Sidewinder expands to provide horizontal attachment in: - 16 ga - 3/16" steel - pudin, tubular steel. Product Features The Sammy X-Press expands to provide direct vertical attachment in: - Metal Deck (22-16 gauge) - Z-Purlin (18-16 gauge) The Sammy X-Press Swivel allows you to hang plumb in extreme roof pitches: - 89" in Z-Pudin - 45" in metal deck for 12/12 pitch Patent Pending Installs in seconds, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. Patent No. 6935,821 Patent Pending MIMM-11, .71 I 8194. J. I" Jniversal X Preso It Tool 1 8195910 ' IT RetroSockettor6151910 1 8152910 XPDR 25/64" Drill Bit I 'Tool Includesi Sleeve, Bit Receiver, Hex ewench, and 25/64 Onll Bit To watch a video demonstration of the Sammy X-Press, visit htlp://wwwsammysuperscrew.comlsammyxpress.htrn 0 __OHS,i 1/4' 8181922 XP 200 X-Press200 1146(22gal 185 (L 250 (Luminaire) .027 .056" 125 25 125 Metal Deck 950 (2%' Pipe) 185 940 12" Pipe( 027' 3i8 8/50922 XP 20 X-Piess20 1146(22ga) (Lurnriaire) 2K (Lurninaire) 1475 (4* Pipe) 175' 25 125 Metal DWI 283 (Conduit & Cab/el 1500(4' Pipe) .060 .. "z 3/8' 8153922 XP 35 X Press 35 1783 (16 gal 250 )Lunnnaire) 1475 (4 Pipe( 125 25 125 Purlin 416 (Conduit & Cable) .056 750 (2" Pipe) 3/8 8294922 SXP 20 Swivel X-Press 20 061 22 970 vertical ILummnaxe) 80 @ 45 (Lemma e) 635 (2 'Pipe) 027' 125' 25 125 Metal Deck , 829 (45 Off Vertical) 283 vertical (Conduit & Cable( 233 @ 45" (Conduit & Cable( 1500(4' Pipe) vertical) 1675 16 I 250 vertical (Luminaire( 3/8' 8295922 SXP 35 Swivel X-Press 1558 (89 8 80 @90° )Luminaire( 635 (2' Pipe( .060' 125' 25 125 Pudin 500 vertical (Conduit & Cable) - 333 @ 89" (Conduit & Cable( r - Ore-Pour Structural Concrete@ 3000 psi Metal Deck Q. 310' 8150922 XP 20 Sarery X P esit20 1146 )22ga) 850 (2"/ Pipe) 25 125 L - ruL-ruu,r ,,uc HORIZONTAL MOUNI 1250 (31/28 Pipe) 3/8' 8293957 SV10(P 35 Sidewinder X-Press 35 1798 (16 gal 80 ILuminairel .060' .125" 25 125 Paulo 416 (Conduit & Cable) Pre-Pour Structural Concrete @3000 pet Post-Pour Range II LWC:5 35 PCF (Ibs! ft'( PIT Top Chord Product Features ,. Fits under the top flute of common metal deck profiles UL Listed to support 8 max schedule 40 pipe. - Distributes load evenly Distributes load evenly over the center bar joist; eliminates Quick and easy to install angle iron distortion. 1200 Lb. load rating (refer to approvals) Quick and easy installation of a trapeze. I Provides rigid seismic restraint Seismic bracing not required when used in top chord I applications. (9.3.5.3.8 NFPA 13). New Keps® Nut/Washer - Integrated nut and washer . - for one piece installation. - Bottom Chord Can be installed from below the joist Distributes load evenly . Quick and easy to install 1200 Lb. load rating (refer to approvals) Can be installed from below the joist. No special tools required. (side view) Made in the U.S.A. I (..,', ..x. Patents Pending Approvals Rod Part Model IT9fl1.ii UL Test LL Load Listed J11r•, Box Size Number I TOP CHORD MODELS 3/8" 8296900 HD38TC I 3/8 lop Chord 1w/Square KEPS 6075 I I I 1200 Maximum 4 Schedule 40 pipe Luminaire Fittings 25 NuVWus er Conduit and Cable — — 1/2" 8298900 HD12TC 1/2" Top Chord T W/ Square KEPS 6075 1200 Max/maw 8" Schedule 40 pipe Luminaire Fittings 25 Nut/Washer Conduit and Cable BOTTOM CHORD i 3/8" 8297900 HD38BC 3/8 Bottom Chord 1w/Square KEPS 6075 1200 Maximum 4 Schedule 40 pipe Luminaire Fittings 25 Nut/Washer Conduit and Cable 4)L 1/2" 8299900 HD12BC 1/2 Bottom Chord T w/ Square KEPS 6075 1200 Maximum 8 Schedule 40 pipe Luminaire Fittings 25 Nut/Washer Conduit and Cable ACCESSORIES Part Number 'rtmc.i. Material Specification Nut Diameter Square Square Internal Washer Washer Dimension Thickness Bag Qty Box Qty NEW—+ 8250200 3/8" integrated KEPS 1010 Carbon Steel WI Electro Zinc 3/16 1-1/2 0.13" 25 100 Nut[Washer Plate NEW—) 8253200 1/2' integrated KEPS 1010 Carbon Steel w/ Electro Zinc 1/2-13 1-1 0.13" 25 100 A Kepse Integrated Nut/Washer Easy two step & :a:e:cte mmy Y4" pre-drilled pilot hole required. Concrete Installahon Tool available for a one tool installation process. ----- I --.C---.............. :1 . S •L.j.' . l \. %J UJ j Metal Deck 1 #14 Black 1/4 8055957 CST 200 5/16x1-3/4 2400 25 125 Nut Driver 3/8' 8059957 CST 20 5/6 xl 3/4 2400 25 125 Part# I 3V 8145925 CST2O-SS 5/16s1 3/4 2400 25 125 8113910 1/2 8060925 CST 2 5116x 144 2400 25 125 :i- * Tested in 3000 P51 concrete #14SW Red SPECIAL NUT DRIV1.R SYSTESU The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each tme. When the face of the driver comes Nut Driver into contact with the material you are installing into continue drilling until nut driver spins free Installation is then complete Warranty requires the use of the appropriate nut driver for Part # installations. 8114910 1 - 8122910 Concrete Installation Kit (a) Kit includes the following items 8113910 #14 Black Nut Driver (b) 8114910 #14 SW Red Nut Driver (c) 1 8116910 #250 Bit (1/4)(d) 1 8117910 SDS Bit (lI4)(e) 8118910 7I32 Wood Bit (f) 1 8120910 HEX 250 Bit Receiver (1f4) (g) 1 8098910 SL 250 Sleeve (h) 1 8121910 SDSB250 Bit Receiver. (V4) *Only sold separately - not included in kit. ONE tool to he hole and DRILL, the anchor! Rotary Hammer Drill into concrete Easy two step process (Drill hole & drive Sammy concrete anchor). Y4" pre-drilled pilot hole required. Concrete Installation Tool available for a one tool installation process. #14SW Red 1!4 8062957 SWC 200 5,116 xl 3J4' Nut Driver P art # 811:911— 3/8' 8061957 SWC 20 5/16 x 1-3/4 2450 25 125 2450 1475 25 125 Tested in 3000 P51 concrete [INSTALIAIION STEPS INTO CONCRETE Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with an electric impact/drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the concrete screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or bolt stock. (#14SWred nut driver used with 1/2" screw) NOTE: Use a 1200 maximum RPM drill for installation. NOTE: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS-'*'-,, INTO CONCRETE:1 Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, predrill the concrete member to a depth of 2" with an impact/drill set on impact mode. After pre-drilllng has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Install the SWC screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. NOTE: Use a 1200 maximum RPM drill for installation. NOTE: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. M_1 11~Lffifilllmuuai1i1Pmi1 SPECIAL NUT DRIVER 50$T00; The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installaton is then complete. Warranty requires the use of the appropriate nut driverfor installatons. a Installation Steps: 2 , Pm-drill a 5/8' hole with a regular drill or hole saw, Insert SST screw into #14 black nut driver. With wing nut and washer - on bolt, insert wing nut thru surface, and begin installation. Prestressed Concrete When bolt is secure and nut driver spins tree, stop drill motor and remove. SST screw is now ready to receive 1/4", 3/8, or Metric all thread rod or bolt stock. L WV . 4 25 3/8" 8064925 SST 30 1/4 x 3' 450 (Lath & Plaster) 25 125 404 (2 Layers 5/8 R oCk) Ji #14 Black Nut Driver Part # 8113910 Product Features; 3/16" eyelet to accommodate common wire size. ICC approvals can be found at www.itwbuildex.com under Evaluation Report # ER-5367 1U(9h1 uvmD I 4.4 x 4i v --i 2: orxitnc, (rrCr 15 1 4 1 1 2 472 (2 1 8110910 CWIT Installation Tool (Does not comply with ROHSrequiremersts) 'I STAY UP TO Product Features; Complies with NFPA 13 Code Changes CODE! w Flashing for dry pendant sprinklers subject to extreme m ore efficient way F temperature changes to flush your One piece construction is easy to install - - refrigeration/freezer units, Pipe diameter markings ensure accurate fit EPDM temperature range of -655F TO + 250F - ..M PUMA 4 1 14 - 1 ' 1 I 2 4uuxs0" I l" - 4-.,,4 .Ill 4 Visit http://w'.itwbuildex.com/dektite,htm for more information. I Rolls" w ICC ly CWIT Installation Tool Part # 8110910 8163910 Assortment Pack neck includes the fottowina items: 8008957 GST 20 * 2" Sammy for wood 8 (.8> 8010957 GST 30 3 Sammy to wood 4j 43. 8021957 SWG 20 2"Sclewinder for wood 4 8028957 DSTR 1 1/420 x 1 Sammy for sled a. 1 I.c3 8046957 TEK - 12-24 x 1-1/2 for steel - .u36- 8055957 SWDR I 1/4-20x 1 fsruleelw/nut 4 dO 8056957 SWDR 516 5/16-18 x 1-114 for steel w/ nut 4 8113910 414 NUT DRIVER Installation Tool Vertical 1 8114910 #14SW NUT DRIVER Installation Tool - Horizontal 1 JIP4III 8123910 Pole Tool 6)3-6) 1 8124910 Pole Tool 12'(4'- 12') 1 8125910 Pole Tool 18)6 18) 1 8126910 Pole Tool 24'(B'- 24) 1 8127910 Socket Driver 1 8128910 Ceiling Woe Socket Dover 1 8129910 Universal Pole Tool Socket Kit 1 The Pole Tool and Universal Socket Kit provide easy and safe installation for: - Sammys - Jack Chain - Threaded Rod - Wire - Pencil Rod - Screws - Ceiling Screws Ideal for retrofit and hard-to-reach projects in - wood and steel. - universal Pole Tool Socket Kit (8129910) Includes: r (Items not sold separately) d) • Adaptor Plug (a) Socket Driver for SAMMYS (b) N) . Socket Driver for Ceiling Wire Screws (c) Socket Driver for 1/4' Standard Nut Drivers (d) Slut Plug for Viper or Ladd Powder Actuated Attachment (e) L' If4'&7 CZ 2000 SNAP 7 181 Cable Hanger, Cal,No.5 C-Z.2000 Plenum Rated Complies with NEC Standards Sammy Saddle attaches to 1/4" or 3/8" threade rod and supports 35 Category 5 cable. - Snap nut anywhere onto threaded rod - Non-corrosive and non-conductive - Supports cable, pipe, or conduit - Multiple hangers per rod - Plenum Rated - Plenum Rated tie wires included - U.S. Patent No. 25 j e,146,076 d 77 USTED 4S16 !2!V 8130910 Spot Rite Le,- I J 1/2", 3/4", and 1" threading Magnetic strip for ease of use Pocket Sized Lightweight 3-vial design for measurement of 00, 45°, and 90° angles SAMMYS® FOR WOOD 8007957 GOT 10 3/8 - Vertical CPVC 1-1/2' 300 1-112' 8020957 SWG 10 3/8 Horizontal CPVC 1-112" 300 1-1/2 8008957 GOT 20 3/8 Vertical 2-1/2' 850 1-1/2 4" 1475 8068925 GST2O-SS 3/8 Vertical 21/2 850 1-1/2 8010957 GST30 3/8 Vertical 4 1500 1-1/2 4' 1475 11/2 8009925 GST 25-380 3/8" Vertical 4 1500 1-1/2" 8022925 SWG 25-380 3/8 Horizontal 3-112 -4"" 1503 -- 1-1/2' 8021957 SWG 20 3/8 Horizontal 2-112 -3"" 1050 1-1/2 8073925 SWG 20-SS 3/8" Horizontal 2-1/2 850 - 1-1/2" 8139957 SH-GST2O 3/8 17" Angle off Vertical 3 1050 1-1/2 4 1475 1-1/2 8141957 SH-GST3O 318" 17" Angle off Vertical 4 1500 1-1/2" 4 1475 1-1/2' SAMMYS® FOR STEEL ' Him I L , 11*A 8038957 üSrc 1 3/8 Ver' ,i - 4 Li) ' 00. 4 1475 .105' 8037957 DSTR 1-1/2 3/8 Vertical 4 1500 035 41 1475 105" 8039957 DSTR 516 3/8 Vertical 4 1500 037" 4' 1475 .105" 8045957 DST 516 3/8 Vertical 4 1500 .188 4 1475 .188" 8046957 TEKSO 318 Vertical 4 1500 .250" 4 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037 4 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4 1500 .037" 4' 1475 .060" 8054957 SWDR 11/2 3/8" Horizontal 4 1500 037 4 1475 .060" 8137957 SH-DSTR 1 3/8"' 7, Angle off Vertical 4 1500 .035" 4 - 1475 .105" 2" 940 .029" 8150922 XP 20 3/8 Vertical 2-1/2' 850 .027" 629 8153922 XP 35 3/8" Vertical 4 1500 060" 4' 1475 '105" 8294922 SXP 20 3/8 Vertical or up 1045" 2 750 027 2 635 .029" 8295922 SXP 3/8 Vertical or, up to 89" 3-1/2 1250 060' 2 635 .023 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 060" SAPJJ1Y® FO R, I nc 8059957 CST 20 3/8" Vertical 4 14" 3000 8061957 SWC 20 3/8" Horizontal . ' 1475 3000 . 8150922 XP 2O - 3/8" Vertical 2-1/2' 850 Pre-Pour Structural @3000p3i 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range It LWC C 35 PCF (lbs/fl3) TRUSSTHANGER 8296900 HD38TC . U. 8297900 HD38BC 3/8" 8198906 HD12C7P 1/2 8298900 HD12TC 1/2" 8299900 H0I2BC 1/2" SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is SWG 25-340 Maximum pipe size in wood timber or joist allowed by UL is 4" "SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1i, SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" Bottom Chord 1200 6075 Maximum 4" Schedule 40 pipe Bottom Chord 1200 6075 Maximum 5 Schedule 40 Pipe Top Chord 1200 6075 Maximum 8" Schedule 40 Pipe Bottom Chord 1200 6075 Maximum 8" Schedule 40 Pipe UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. 2" Fastening requirement 5 times weight of water-tilled schedule 40 pipe plus 250 pounds. Cus LISTED PIPE HANGER ALSO LISTED AS CONDUIT MID CABLE HARDWARE APPROVED ALSO LISTED AS ANCHOR FOR LMINAlRE 9021 8150922 XP 20 3/8 Vertical 185 8153922 XP 35 3/8" Vertical 250 185 8181922 XP 200 114" Vertical Vertical 170 8294922 SXP 20 3/8' 45* 80 Vertical 250 8295922 SXP 3S 3/8 900 80 8293957 SWXP 35 3/8" Honzontal 80 TRUSS-T HANGER® .027" .035" .027" .035" .035" .027" .027" 080" .060" .060" 8296900 HD38TC 3/8" 8297900 HD38BC 3/8" 8196900 ltD12CZP 8298900 HD12TC 1/2' 8299900 HD12BC 1/2' Top Chord 1200 6075 Overhead Lighting & Luminaire Fittings Bottom Chord 1200 6075 Overhead Lighting & Luminaire Fittings Bottom Chord 1200 6075 Overhead Lighting & Luminave Fittings Top Chord 1200 6075 Overhead Lighting & Lam noire Fittings Bottom Chord . 1200 . 6075 Overhead UttVng & Luminaire Fittings Ia] I1 41I .OIlUUlL, I UUuIIy, dilU 8150922 XP 20 3/8 Vertical 283 027' 8153922 XP 35 3/8" Vertical 500 .060' 8204922 SXP2O3/8" .Vertical 283 .027" 8295922 SXP 35 3/8" Vertical 500 .060" 8293957 SWXPSS 3/8 Horizontal 500 060 Max 4 tradesize EMT, RMC and IMC & 5 trade size ngid PVC conduit Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit_ Max 4 tradesize EMT & 6 trade sze RMC MC, and rigid PVC conduit Max 4 trade sze EMT & 6 trade sze RMC. MC, and rigid PVC conduit Sheet Steel Sizes Gauge No. 2298 20ga 18ga. 16ga. 4 rt 129a 3/16" 1/4" Nominal Decimal Equivalent .030' .036 .048 .060 .075 .105" .188" .250" TRUSS-T HANGER® HD38TC 3/8" Top Chord 1200 6015 IID38BC 3/8" Bottom Chord 1200 6075 HD12CZP 1/2 Bottom Chord . 1200 6075 HD12TC 1/2" Top Chord 1200 6075 HD128C 1/2" Bottom Chord 1200 6075 &S PIPE HANGEUSTED R ALSO LISTED AS CONDUIT HAD CABLE HARDWARE APPROVED ALSO LISTED AS ANCHOR FOR LUMINRJRU 9021 8296900 8297900 8198900 8298900 8299900 Up to 6" Trade Size EMT, tMC and Rigid PVC conduit Up 106" Trade Size EMT, IMC, and Rigid PVC conduit Up toO" Trade Size EMT, IMC, and Rigid PVC conduit Up 106' Trade Size EMT, IMC, and Rigid PVC conduit Up to 6' Trade Size EMTIMC, and Rigid PVC conduit FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response ...,- .,.- 4 -- V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent \4tauIic 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2713 mm K Factor: 5.6 Imp./8.1 SI.1 Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Approvals/Listings: c®@® CE 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to I4719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner Engineer System No Spec Section Location Paragraph Contractor Approved victaulic.corn I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. ictauliC 1 victau..c.c.om I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS 011000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: El Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS 065100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: El Open End: V27 El Recessed: V27-2 Sprinkler Finishes: El Plain Brass El Chrome plated El White painted3 El Black painted3 El Custom painted3 Eli Proprietary Nickel Teflon2 coating3 El VC-2504 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. i updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 2 AtaUIi vic.tau!ic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 I V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) i 1/2" 1/2" 1/2" 1/2" 1/2° 1/2" Orifice Size (mm) 13 13 L 13 13 13 Nominal KF ctor..!.m.pe.....5 ... .5.6 .........56 .56 Nominal K Factor S.1.1 8.1 8.1 8.1 8.1 _ponse Standard Standard Standard Qukk Quick Quick Deflector Type Upright Pendent Recesse Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 1550F/68°C 135°F/57°C 155°F/68°C °F 7°C 1 °F/57°C 135°F/57°C 155°F/68°C 155°F/680C 155°F/68°C 35:F/57:C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/1410C 286°F/1410C 286'F/1410C200°F/930C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135 F/57C 135 F/57C 155°F/68°C 155°F/68 °C 135°F/57°C 155 68 68 135°F/57°C FM 175°F/79°C 175°F/79°C 155°F/68°C 175 79 1750F/79'C 175°F1790C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 30C 200*F/93*C 286°F/141°C 286°F/1410C 200°F/93°C 20 FJl94C 2 86 286°F/141°C 200°F/930C 360°F/182°C 360°F/182°C 135°F/570C 135°F/57°C °F ° °F 7°C 1350F/570C 155°F/68°C 5:/:C 155°F/68°C 155°F/68°C 155°F/68"C 35;/57:c NYC/MEA 62-99-E 175°F/79°C 175°F/79°C 175°F/79°C l oFC 200°F/93°C 200°F/93°C 2860F/1410C i 2860F/141°C i 286 *F/1410C 2860F/141*C 2860 F/ 141 0C 200°F/93°C 360°F/182°C 360°F/1820C 135°F/57°C 155°F/68°C 135°F/570C °F 7°C 1 °F/ 7°C 135°F/57°C 5;/8:C 1550F/680C 155°F/680C 1550F/680C CSFM 7690-0531:112 175 175°F/79°C 175°F/79°C 175°F/79°C 155OF/68'C 200 200F/93C 200°F/93°C 200°F/93°C 200°F/930C 1750F/79°C 286°F/141°C 286°F/141°C 286 F/141 C 286'F/1410C 286 F/141 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 155°F/68°C 1350F/57°C LPCB 175°F/79°C None None 155°F/680C None None 200°F/93°C 175°F/79°C 2860F/141°C 200°F/93°C 360°F/1820C 135°F/57°C 135°F/570C 135'F /570C 1 °F 57° 155°F/680C 155°F/68°C 135°F/57°C °F° 68 1°F °C 135°F/57°C VNIlP 1750F/790C 175°F/790C 1550F/680C 17°F 1175017/79°C 155°F/68°C 200°F/93°C 2860F/1410C 200°F/930C 286°F/1410C 175°F/790C 2000F/930C 200 93 .175°F/79°C 200°F/93°C 286 F/141 2°F/141°C 86 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C I 155°F/680C None 155°F/680C 155°F/680C None 200°F/930C 200°F/930C 200°F/93°C 2000F/93°C 1350F/57°C 135°F/57°C 155 F/68C 1550F/680C VdS 175?/79c None None 1750F/79°C None None 230C 200°F/930C 286 F/141 C 360°F/182°C 135°F/57°C 135 F/57C 155°F/68°C 155 68 CE 175°F/790C • None None 1750F/790C None None 200°F/93°C 286 F/141 C 360°F/182°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victa.uliçc.om 3 •ctauI.' 37 mm 6C 1W! 41 mm 2W! 60 mm victauhc.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: Standard Pendent - Standard upright - V2707, V2708 V2703, V2704 2W/60 mm Max. Hole 2/51 mm Mix Hole 30 mm Typical Ceiling ill 17 mm 111467 T:JLr Finished Surface 30m 43mm MAXIMUM RECESS 2R1/ - 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 1w/ 24 mm 75 mm MAXIMUM EXTENSION 3/4"Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 4 '.js(tauI.c 2' 4' 6' 8' 10' 12' 14' 0.6,0 1.200 1.8,0 2.40, 3.Om 3.7rn 4.30, Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory vic.tau c.comI Sprinklers I FireLock8 I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent 2 4 6' 8' 10 12' 14' 16 0.60, 1.201 I.S. 2.4n, 3.00, 33— 430, 4.3,0 NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. C. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 5 ,JtaUuic. 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 7psi 48 kPa is psi 103 kPa 30 psi 207 kPa Available Wrenches: vctau..c.c.ornI Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Temperature - °FI°C Maximum Sprinkler Victaulic Nominal Ambient Glass Temperature Part Temperature Temperature Bulb Classification 1 Identification Rating Allowed Color Ordinary A 135°F/57°C 1000F/380C Orange Ordinary C 1550F/68°C 100017/380C Red Intermediate I E 1. 175°F/790C 150°F/65°C Yellow Intermediate F 200°F/93°C 150°F165°C Green High J 286°F/141°C .2251F 8/10716 Blue Extra High K I 360°F/1820C 300°F/149°C Purple - M Open - No Bulb 'Standard response only. 8 150/65 if wax coaled. WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in POF format on our website at victaulic.com. Warranty Refer to the warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victa.Iiçom 6 . ,ctauI. Y LL ]V[DDSE M~E 1,111 ~ 11,111,1171.11 Will I IV J t11111 110 fill ASTMA135, Grade A ASTM A795, Type E, Grade A Pressure rated to 300 psi Underwriters Laboratories- United States of America Underwriters Laboratories-Canada Factory Mutual NFPA-13 NFPA-13R NFPA-14 CIVIL DEFENSE APPROVAL- United Arab Emirates Made in the United States of America UL, ULC & FM listed for roll-groove, plain-end and welded joints for wet, dry, preaction and deluge sprinkler systems. LEED v4 Certified Lii] I*['L1t4'!1 IR4 I FINISHES AND COATINGS Schedule 10 & 40 Sprinkler Pipe receives an OD mill coating of water-based paint which has corrosion protection expected with a painted carbon steel product, i.e. it would be expected to resist corrosion for an extended and indefinite period in a clean and dry environment and, as environmental conditions deteriorate, the corrosion protection would also diminish. Schedule 10 & 40 Sprinkler Pipe (black) receives an ID mill coating of Eddy Guard II MIC preventative coating. EG2 has been tested at independent laboratories to resist bacterial growth and maintain minimal bacterial count after multiple flushes (25) of the pipe. Schedule 10 & 40 Sprinkler Pipe when Hot Dip Galvanized by ASTM Al 23 and supplied by Bull Moose Tube is UL listed and FM approved. PRODUCT IDENTIFICATION Every length of Bull Moose fire sprinkler pipe features large, easy-to- read, continuous stenciling, clearly identifying the manufacturer, type of pipe, size, and length. 717 7 777 TE, :'. 1315 1.660 1.900 2.315 2.815 3.500 4.500 6.625 8.625 Lo' (in 1.091 1.442 1.682 2.157 2.635 3260 4260 6351 8249 EmptWeIit(ib/ft) 1.410 1.810 2.090 2.640 3.530 4340 5.620 9.290 16.940 Water FlOed weIght (ID/ft) 1.800 15.21 2.518 -_3.053 4223 5.893 - 1.951 11.196 1 23.038 40.086 9.91 1.76 6.27 4.92 3.54 2.50 1 1.158 1.805 PlecperLlft 91 61 61 37 30 19 19 10 7 1315 1.660 1.900 2375 2.875 3.500 4,500 LB. (In) 1.049 Empty Weight (lb/fr) 1.680 7380 2.270 7.610 2.720 2.061 3.660 2.469 5.800 3.068 1.580 4.026 10.800 Water flhidWe1gflt(Ib/ft) 2.055 2.918 3.602 5.114 1.815 10.183 16316 1.00 1.00 1.00 1.00 1.00 1.00 1.00 70 51 44 30 30 19 19 *Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category vizv SUBMITTAL INFORMATION Project (& C (& <.13> Comments C) Schedule 10- Black (" ) Schedule 10 - Hot Dip Galvanized Schedule 40 - Black () Schedule 40- Hot Dip Galvanized BULLIVIDDSETUBE.CDM L1 .LTi @iIb 1' 'N MALLEABLE IRON FITTINGS Class 150 (Standard) FIGURE 1125 L......J Reducer Size ________________ M Unit W eight Black Galv. NIPS DN NIPS DN in mm lbs kg lbs kg II II '' ( I I * Sizes 1/2 a 1/4 3/4 /2 and 1 33/4 do not have bands at the reducing end. '/4 8 1/8 6 1 25 0.07 0.03 0.07 0.03 /8 1/8 6 1 1/8 29 0.11 0.05 0.11 0.05 1/4 8 0.11 0.05 0.11 0.05 1/2 15 1/8 6 11/4 32 0.14 0.06 0.14 0.06 1/4* 8 015 007 015 007 1/8 10 017 008 017 008 3 /4 20 1/8 6 1A6 37 024 011 024 011 1/ 0 /4 0 0.22 0.10 0.22 0.10 3/ 10 025 011 025 011 1/2* 15 0.27 0.12 0.27 0.12 1 25 1/4 8 1 A6 0.35 0.16 0.35 0.16 10 0.35 0.16 0.35 0.16 ½ 15 0.39 0.18 0.39 0.18 20 11/4 32 1/2 15 21A6 52 0.61 0.28 0.61 0.28 3/4 20 0.64 0.29 0.64 0.29 1 25 0.68 0.31 0.68 0.31 1 1/2 40 1/2 15 2A6 0.78 0.35 0.78 0.35 3/4 20 0.88 0.40 0.88 0.40 1 25 0.88 0.40 0.88 0.40 11/4 32 0.90 0.41 0.90 0.41 2 50 1/2 15 213A6 73 1.30 0.59 1.30 0.59 3/4 20 1.34 0.61 1.34 0.61 1 25 1.40 0.63 1.40 0.63 11/4 32 1.53 0.69 1.53 0.69 11/2 40 1.55 0.70 1.55 0.70 21/2 65 1 25 31/4 83 2.12 0.96 2.12 0.96 1/4 32 2.09 0.95 2.09 0.95 11/2 40 2.09 0.95 2.09 0.95 2 50 2.51 1.14 2.51 1.14 3 80 1 25 3Ae 94 3.16 1.43 3.16 1.43 11/4 32 2.99 1.36 2.99 1.36 11/2 40 3.30 1.50 3.30 1.50 2 50 3.25 1.47 3.25 1.47 21/2 65 3.31 1.50 3.31 1.50 31/2 90 2 50 4 102 4.32 1.96 4.32 1.96 21/2 65 4.72 2.14 4.72 2.14 3 80 4.99 2.26 4.99 2.26 4 100 _______________ 11/2 40 43/8 111 4.90 2.22 4.90 2.22 2 50 5.10 2.31 5.10 2.31 21/2 65 5.93 2.69 5.93 2.69 3 80 6.55 2.97 6.55 2.97 3½ 90 6.30 2.86 6.30 2.86 5 125 4 100 49Ae 116 9.57 4.34 9.57 4.34 6 150 4 100 413A6 124 10.30 4.67 10.30 4.67 Note: See following page for pressure-temperature ratings. Galvanized weights may vary. Please contact your Anvil Representative if you need verification. All Elbows & Tees 3/ (10 ON) and Larger are 100% Gas Tested at a Minimum of 100 PSI. (6.9 bar) PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: ]Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PF-6.1 3 MALLEABLE IRON FITTINGS Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature ____________ Pressure Class 150 Class 250 Class 300 (°F) (°C) si ha psi jar Ps br .200 to 150° -28.9° to 65.60 300 20.7 500 34.5 ____________ 600 41.4 2000 93.30 265 18.3 455 39.4 550 379 2500 121.10 225 15.5 405 279 505 343 3000 148.9° 185 12.8 360 228 460 3i. 3500 176.7° 150 10.3 315 2:.7 415 28.8 4000 204.4° 110 7.6 270 18.6 370 25.5 450° 232.20 75 5.2 225 15.5 325 22.4 5000 260.0° - - 180 12.4 280 19.3 550° 287.80 - - 130 5.0 230 15. Note: Unions with Copper jr Copper Alloy seats are nor intenced for use where temperature exceuds 450°F c®us APPROVED For Listings/Ap)roial Details and LimitationE, visit our website at www.anvilinti.cc.m or contact an Anvil Sales Representative. Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 __________ Sizes %- ('6-25 mm) Sizes 11/4_2 (32-51 mm) Sizes 21/2 -3 (64-76 mm) CFo (°C) psi bar ps p bar ps) bar -200 -28.90 to to 330 20.7 15cc 65.60 2,000 137.9 1,500 103.4 1:00 68.9 2000 93.3 235 18.3 1,785 123.1 1,350 93.1 90 627 2500 121.11 225 15.5 1,575 103.6 1,200 82.7 825 56.9 3000 148.9 1 185 12.8 1,360 9...8 1,050 72.4 735 50.7 3500 176.71 150 10.3 1,150 79.3 900 62.1 650 44.8 400° 204.4 - - 935 64.5 750 51.7 560 38.6 450° 2322 - - 725 50.0 600 41.4 475 328 5000 260.0 - - 510 35.2 450 31.0 335 26.5 550° 287.8 - - 300 20.7 1 300 20.7 300 20.7 Anvil Class 150/300 Malleable Iron Fittings conform to ASME 516.3 and Unions conform to ASME 516.39. ALL ELBOWS & TEES s/n" (10 DN) and LARGER ARE 100% GAS ESTED AT A MINIMUM OF 100 PSI. (6.9 bar) Standards and Specifications Dimensions Material Galvanizing* Thread Pressure Rating MALLEABLE IRON FITTINGS Class 150/PN 20 ASME B 16.3 ASTM A-197 ASTM A-153 ASME Bi 20.1 ASME 816.3 Class 300/PN 50 A:SME 816.3 ASTM A-197 ASTM A-153 _j ASME 81 20.1 ASME B16.3 MALLEABLE IRON UNIONS Class 150/PN 20 ASME B16.39 ASTM A-197 ASTM A-153 ASME Bi 20.1 ASME B16.39 Class 250 ASME 137 6.39 ASTM A-i 97 ASTM A-i 53 ASME 131 20.1 ASME B16.39 Class 300/PN 50 ASME B 6.39 ASTM A-i 97 ASTM A-i 53 ASME Bi 20.1 ASME Bi 6.39 ASTM B 633. Type I, SC 4, may be supclied as ale.rnate zinc coating per applicable ASME 1316 poduct standard. PF-11.15 MALLEABLE IRON FITTINGS O-W 'AWIL General Assembly of Threaded Fittings 1) Inspect both male and female components prior to assembly. Threads should be free from mechanical damage, dirt, chips and excess cutting oil. Clean or replace components as necessary. 2) Application of thread sealant Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant may be utilized. Thoroughly mix the thread sealant prior to application. Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3) Joint Makeup For sizes up to and including 2' pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1/2" through 2" thread varies from 41/2 turns to 5 turns. For 2 '/2" through 4" sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 2 '/2" through 4" thread varies from 5'/2 turns to 6/4 turns. PF-11.13 CAST IIRON THREADEDFITTINGS ii _______ Class 125 (Standard) LI FIGURE 351 900 Elbow Size A B Unit Weight Black .. j, 1 h-B -H ---------- I -I NPS ON in mm in mm lbs kg 1/4 8 1/2 13 13/16 22 0.16 0.07 10 9/16 14 15/16 24 0.25 0.11 1/2 15 11/16 17 11/8 29 0.40 0.18 3/4 20 1 /16 22 115/16 33 0.60 0.27 1 25 15/16 24 11/2 38 0.92 0.42 11/4 32 11/8 29 1/4 44 1.44 0.65 11/2 40 1/16 33 115/16 49 1.95 0.88 2 50 1/16 40 21/4 57 3.13 1.42 21/2 65 113/16 47 211/16 68 4.94 2.24 3 80 2/16 56 31/8 79 7.21 3.27 31/2 90 2/16 62 3/16 87 9.67 4.39 4 100 211/16 68 313/16 98 12.17 5.52 5 125 3511e 84 41/2 114 21.46 9.73 6 150 3/8 98 51/8 130 31.33 14.21 8 200 5/16 132 6/16 167 64.56 29.28 Note: See following page for pressure-temperature ratings. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: []Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PF-6.1 3 CAST IRON THREADED FITTINGS 0-W Anvil standard and extra heavy cast iron threaded fittir.gs are manufactured in accordance with ASME B16.4. Plugs and bushings are manufactured in accordance wit ASME 616.14. NOTE: Figure 367 Concentric Reducers do not meet the overall length requirement of ASME B16.4. All other dimensions are in comp[ianc. ceus <:S~> APPROVED For Listings/Approval Details and Limitations, visit our website at www.aitilintl.com or contact an Anvil Sales Representative. Cast Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 125 Class 250 (°F) (°G Lpsi !bB- Jpsi bar -200 to1500 -28.9t065.6 175 12.1 400 27.6 2000 93.3 165 11.4 370 25.5 2500 121.1 150 10.3 340 23.4 3000 148.9 140 97 310 21.4 3500 176.7 125 8.5 300 20.7 4000 204.4 - - 250 172 Standards and Specifications Dimensions Materia Galvanizing* J Thread Pressure Rating CAST IRON THREADED FITTINGS Class 125 ASME 1316.4 , ASTM A-i 26 (A) ASTM A-i 53 ASME 131 .20.1 ASME 1316.4 Class 250 ASME 1316.4 It ASTM A-i 26 (A) F ASTM A-i 53 ASME 131 .20.1 ASME 1316.4 CAST IRON PLUGS AND BUSHINGS I ASME 13116.14 ASTM A- 126 (A) ASTM A-i 53 I ASME 131 .20.1 AME 131 6.14 * ASTM B 63. Type I, SC 4, nay be supplied as alternate zinc coating per applicable ASME B16 product standard. PF-11.16 CAST IRON THREADED FITTINGS O-W.AWIL General Assembly of Threaded Fittings 1) Inspect both male and female components prior to assembly. Threads should be free from mechanical damage, dirt, chips and excess cutting oil. Clean or replace components as necessary. 2) Application of thread sealant Use a thread sealant that is fast drying, sets-up to a semi hard condition and is vibration resistant. Alternately, an anaerobic sealant may be utilized. Thoroughly mix the thread sealant prior to application. Apply a thick even coat to the male threads only. Best application is achieved with a brush stiff enough to force sealant down to the root of the threads. 3) Joint Makeup For sizes up to and including 2' pipe, wrench tight makeup is considered three full turns past handtight. Handtight engagement for 1/2" through 2" thread varies from 41/2 turns to 5 turns. For 21/2" through 4" sizes, wrench tight makeup is considered two full turns past handtight. Handtight engagement for 21/2" through 4" thread varies from 51/2 turns to 6/4 turns. PF-11.13 Victaulic® VicFlexTM Sprinkler Fittings JtauIicr Series AH2 and AH2-CC Braided Flexible Hoses 10.85 Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component Series AH2 1"IDN25 Nominal ID Braided Hose: 31, 36, 48, 60, 72/790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.757140mm straight reducer. Series AH2-CC 1'IDN25 Nominal ID Braided Hose: 31, 36, 48, 60, 72/790, 915, 1220, 1525, 1830 mm. Note: length includes captured coupling and 5.757140mm straight reducer. Sprinkler Reducers: Sprinkler Connections: ½ and %I15 and 20 mm Straight Lengths: 5.75, 9, 13/140, 230, 330 mm 900 Elbows: Short (typically used with concealed sprinklers) Long (typically used with recessed pendent sprinklers) Low Profile Short (for use with Style AB5, AB11, AB12, ABBA and ABMM Bracket) Low Profile Long (for use with Style ABS, AB11, AB12, ABBA and ABMM Bracket) Inlet Connections: 1'725 mm Grooved lGS 1'725 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. 3/4'/20mm NPT or BSPT adapter nipples available for VdS. 11/4"/ 32 mm BSPT adapter nipples available for LPCB. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. stemNo..............Spec J Paragraph Submitted By Date Approved Date victaulic.com 10.85 5839 Rev AG Updated 07/2019 © 2019 Victachc company. All rights reserved. 1 ictaulic victaulic.com p 1.0 PRODUCT DESCRIPTION (Continued) Brackets: Style AB1 for suspended and hard-lid ceilings and sidewalls, allows installation before most ceiling tiles in place Style A82 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place Style A133 for surface mount applications, wood, metal and block walls, or ceilings Style A134 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment Style A135 for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment Style A137 for suspended and hard-lid ceilings Style A137 Adjustable for suspended and hard-lid ceilings Style A138 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) Style A139 for hard-lid ceilings with hat furring channel grid systems Style AB10 for Armstrong® TechZoneTM ceilings Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 900 low profile elbows) Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 47100mm. Style ABBA bracket for suspended, exposed, and hard-lid ceilings Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings Maximum Working Temperature 225°F/107°C Maximum Working Pressure 200 psi/1375 kPa (FM Approval) 175 psi/1206 kPa (cULus Listed) 1600 kPa/232 psi (VdS/LPCB Approved) 1.4 MPa (CCCf Approved) Connections To adapter nipple (inlet) via 1725.4mm Grooved IGS 1"/25.4mm NPT or BSPT male thread 3/4720 mm BSPT male thread (VdS only) 11/4'732 mm BSPT male thread (LPCB only) To sprinkler head (outlet) via ½ or 3/4715 mm or 20 mm Minimum Bend Radius 77178 mm (FM/CCCf Approval) 2/51 mm (cULus Listed) 3776.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors FM (1/2715 mm reducer) K5.6/8,1 (SI.), (3/4 /20mm reducer) K14.0/20,2 (S.!.) cULus (1/2"/15 mm reducer) K8.0/11,5 (SI.), (3/4 /20mm reducer) K14.0/20,2 (Si.) VdS/LPCB (1/2"/15 mm reducer) K5.6/8,1 (S.!.), (3%/20mm reducer) K8.0/11,5 (S.l.) 10.85 5839 Rev AG Updated 07/2019 02019 Victauic Company. At rights reserved. victaulic.com 2 __________ victaulic.com 2.0 CERTIFICATION/LISTINGS NOTE The VicFiex Series AH2 Hose has been tested and evaluated by Spears® for acceptable use with Spears® CPVC Products and is therefore covered under the Spears® FlameGaurd® Installer Protection Plan, 3.0 SPECIFICATIONS - MATERIAL Series AH2 ' Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc Plated Reducer (1/2'715mm or 3/41/20mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Coupling Retainer Ring: Polyethelene Nut and Nipple: Carbon Steel, Zinc Plated Reducer (1/2715 mm or 3/4'/20 mm): Carbon Steel, Zinc-Plated Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: Orange enamel (North America, Asia Pacific). Red enamel (Europe). Hot dipped galvanized. Gasket:' Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Services listed are General Service Guidelines only, It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victauic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible, Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type Ill Finish 10.85 5839 Rev AG Updated 07/2019 02019 Victaulic Company. All rights reserved. victaulic.com 3 _11-'AC_t:a_U1ie I all I Ill all Hose Length A B inches inches inches mm mm mm 31/790 24.5/622 29.8/757 36/915 29.5/749 34.8/884 48/1219 j 41.5/1054 46.8/1189 60/1525 53.5/1359 58.8/1494 72/1830 655/1664 708/1798 - victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose Q C4 Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31/790 253/641 31/790 36/915 31.3/794 36/915 48/1219 423/1073 48/1220 60/1525 543/1378 60/1525 72/1830 66.3/1683 72/1830 Series AH2-CC Braided Hose 10.85 5839 Rev AG Updated 07/2019 © 2019 Victauiio Company. All rights reserved. victaulic.com 4 JtUliC 10.85 5839 Rev AG Updated 07/2019 © 2019 Vicfauiic Company. All rights reserved. victaulic.com 5 victaulic.com 4.0 DIMENSIONS (Continued) Standard Reducer 1I.HU 111r11r11I111r11ht11 fjjj1 5.75/140 mm straight reducer Optional Reducers 9.0/229 mm straight reducer 3.07330 mm straight reducer 2,62'2/ 66.5 mm T . 4.83/ 122.7 mm Short 90° elbow reducer Long 90° elbow reducer NOTE The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. FM/VdS Approved only. Low Profile / 2.84/ 72 mm 36 Short 90° elbow reducer Long 90° elbow reducer NOTE Style ABli: When low profiles elbows are used with the Style AB1I bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. victaulic.com 4.1 DIMENSIONS VicF!ex Brackets Style AB1 10, Suspended Ceilings Hard-Lid Ceilings (FM Only) rL" Item Description 1i247610mrnor48"i219rnm Square 2 Patented Center Bracket 3 End Bracket NOTE Both sizes FM/VdS/LPCB Approved, cULus listed Style AB2 Suspended Ceilings Hard-Lid Ceilings Item Description 1 24/610mnor48 /1219rnmSuareBar 2 Patented Vertically Adjustable Center Bracket 3 End8racket NOTE Both sizes FM/VdS/LPCB Approved, cuLus listed Style AB3 Surface Mount Applications FM/LPCB Approved 10.85 5839 Rev AG updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 6 Ac _ta _U1 ii U victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB4 Hard-Lid Ceilings with Hat furring channel grid system Item I Description 1 24 'olommor48ll2l9mmSquareBar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel NOTE Both sizes FM/VdS/LPCB Approved. cULus listed. Style AB5 Hard-Lid Ceilings [ Item Description L1_ 24"/610 m m or 48/1219mm Square Bar 12t Patented Vertically Adjustable Center Bracket End Bracket NOTE Both sizes FM/VdS/LPCB Approved, cULus listed. Style AB7 Suspended Ceilings Hard-Lid Ceilings ........... Item Description 24"/61 Omm or 48 /1219mmSquare Bar 1 2 Patented 1-Bee[ Center Bracket 3 1 End Bracket __J NOTE Both sizes FM/VdS/LPCB Approved. Style AB7 Adjustable Suspended Ceilings Hard-Lid Ceilings [jtem Description L 1 i. 700 mm or 1400mm Square Bar 2 Patented 1 -Bee2l Center Bracket 3 . End Bracket (adutable) NOTE Both sizes FM/VdS/LPCB Approved. 10.85 5839 Rev AG Updated 07/2019 02019 Victaulic Company. All rights reserved. victaulic.com 7 Ac—ta—ulic~ victaulic.com 4.3 DIMENSIONS VicF!ex Brackets Style AB8 Hard-Lid Ceilings L_Item Description L1 j 700rnmorl400mm Square har 2 Patented Vertically Adjustable Center Bracket End Bracket NOTE Both sizes FM/VdS/LPCB Approved. Style AB1O Suspended ceilings Armstrong® TechZone Item Description /152mm Squere Bar 2 Patented 1-Beer Center Bracket [ f-j End Bracket .._.J NOTE FM/VdS/LPCB Approved, cULus listed. Style AB11 Suspended ceilings Hard-Lid ceilings Item Description L 1 24/dlornrnor48/1219rnrnSquareBar Patented 1 Bee2 Center Bracket 3 End Bracket J NOTE FM/VdS Approved, cULus listed. Style AB12 Suspended ceilings Hard-Lid ceilings Item - Description 1 Style AB1 2 Bracket Body #2 ...areDriv Drive NOTE FM/VdS Approved. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com victauliccom 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA Floor-above mount Cantilever mount Temporary mount in exposed ceilings Item Description Style ABBA Mounting Plate 2 Style ABBA Square Br Cap Screw, Serated Flange, M6 x 1 x 20, T25 Tan< Drive Recessed 4 Style ABMM Bracket Body Cap Screw, Serated Flange, M6 x 1 x 15.24, T25Torx Drive Recessed Style ABMM Surface mount Standoff mount Item Description L 1 Style ABMM Bracket Body 2 Cap Screw, Serated Flange, M6 x 1 x 15.24, L T25Torx Drive Recessed 10.85 5839 Rev AG Updated 07/2019 02019 Victautc Company. All rights reserved. victautic.com 4tauuicr victauflc.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB1 Bracket A Bracket See Chart Assembly 1~/ho mrs 2%,'/GB r lie Style AB1 max. hole max. hole 2'75l mm 2W/60 .—.m / min. hole min, hole TcO'h?ng Ele 15.9 mm Typ ceiling tile ical ceiling I tri See note ceiling lace ----- -24/610mm or --'- V27 V38 48/1219mm on Pendent Center NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 10 __________ victaulic.com 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket NOTE Variations of ceiling grids sprinkler heads brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 02019 Victaulic Company. All rights reserved. victaulic.com victaulic.com 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket min. hole min. hoe —L-- NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permtterJ but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 02019 Victauiic Company. All rights reserved. victautic.com 12 ',.J t a uI a c vctauIic.com 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket A See Chart Sachet Assemhy .55J tm 25/765 rem mm Style 665 -Sw: yI mae, he: mae. hoe max. hole t, 2r5i met 2W/riO mm 2'/c I mm min. hole min. hole mirr.hoie nished wail I 6 Cb mm / Stud C/C V27 V38 V27 Pendent Sidewall Hose Clearance Chart -- - - Straight Reducer - - "V2707 V3802 V2709 V2707 V3802 V2709 i V2707 V3802 V2709 3/4 120mm i 1/2'113mm 3/4"120mm 1 3/4 120mm ½ll3mm 1 3/4 120mm 3/4'120mm 1 ½ll3mm 3/4"120mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm R Minimum 20 30 70 Bend Radius 50 80 175 "A' Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11.1 Installation 158 196 155 178 221 180 279 323 282 Space ___________ __________ Hose Clearance Chart Low-Profile Long Elbow Long Elbow Short Elbow V2707 V3802 V2709 V3802 V3802 I 3/4 120mm i 1/2 113mm 3/4'120mm 1/2"113mm ½'113mm Max Recess Max Recess Sidewall Max Recess Max Recess inches i inches inches inches inches - mm mm mm mm mm R felinlmurn Bend Radius - "A" Minimum Required 3.5 4.9 3.6 2.9 3.3 Installation 89 124 91 74 84 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 02019 Victaulrc Company. All rights reserved. victauhc.com 13 4ta uiacr vktaulic.com 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 21vr60mm r Bracket Max. ho4 I Assembly 2`151 mm A j Style 5811 m:rr. hole See Chart 76nm LT /43 mpl khed Tyraical / Vail mm ceiling face ceing g/d / Tp1ca ceiling 1! le See Note J 24'/610mmor _. V27 48/1219mm on center Pendent V38 Hose Clearance Chart Low-Profile 1 Low-Profile Long Elbow Short Elbow 12707 V3802 1/4 120mm ½°I13mm Max Recess". Max Recess inches inches MM mm A Minimum Required 40 39 Installation 102 99 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AG Updated 07/2019 02019 Victaulic Company. All rights reserved. victaulic.com 14 j taukce Ph dI1 e V2707 W'/12.7 nrn MAX. RECESS 5 Sse1be 52707 W/19 MAX. RECESS S 1C/35S.6 victaulic.com 4.9 DIMENSIONS Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Low Profile Short Elbow Suspended Ceiling Grid with Recessed Sprinkler and Straight 5.75"/140 mm Reducer Low Profile Low Profile Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer ~719mmi 3/4"I19mmi ~/19mmi /419 MM 3/4119 MM Recessed* Concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed lConcealed inches inches inches inches inches inches inches inches i inches i inches mm . mm mm mm mm mm i mm mm mm mm Minimum Required 4.0 5.5 5.6 7.2 5.9 73 7.7 9.3 15.0 I 16.6 A Installation Space 1016 1397 1 1422 1829 149 1905 1 1956 1 2362 3810 4216 Distance from Top of i05 20 15 15 15 15 30 30 30 30 B Typical Ceiling Tile toi 12.7 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 BottomofGate I i * Adjustability will he limited Style ABMM Bracket Stand-off Dimensions - 2.22/ I 56mm L mill l00 ,.m /5rm 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. 15 \4taUlic r victaulic.com 4.10 DIMENSIONS Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler 2/51 mm mm. hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm i mm mm mm Wall Thickness 2 4 6 8 10 2 4 6 8 10 A 50 100 150 200 250 50 100 150 200 250 Outlet Length 575 9 13 9 13 13 13 575 9 13 575 9 13 9 13 13 13 B 14612286 3302 1461 22863302 2286 3302 612286I3 3O2_1461 25 3302 2286j3302 1 330.2 330,2 Hose Clearance, 116 148 188 C 2J376 478 96 128 168 108 148 128 108 126 158 198 106 243 325 427 i 275 376 325 275 319 402 503 268 138 351 178 118 138 118 452 300 402 1 351 300 Bend Radius 7 175 8 200 NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences Irorn the iigures above. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaelc Company. All rights reserved. 16 A taUiicr Maximum Number of 90° Bends at 2751 mm Bend Radius victauIiccom 5.0 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.757140 mm Reducers USTED Style AB1, AB2, AB4, AB5 and AB10 Brackets inches/mm inches/mm/type Equivalent Length of 1733.7mm Sch. 40 Pipe (C=120) feet/meters ,' /15/Straight 16,49 31/790 17/52 /2/15/Straight 21/64 - 36/915 '/4'/20/Straight 23/7.0 /7/13/Straight 32/9.8 48/1220 //20/Straight 37/11 3 ½/is/Straight 46/14.0 60/1525 3/4 /20/Straight 46/14.0 Y'15I!ht * * 55/16.8 72/1830 -Y4°/20/Straiqht 53/16.2 Series AH2 and AH2-CC Braided Hose with 90° Low Profile Elbows USTED Style AB11 VicF!ex Bracket Maximum Equivalent Length Number of of 1133.7 mm , 90° Bends at 2751 mm Sch. 40 Pipe Bend Radius inches/mm inches/mm feet/meters W/15 24/7.3 4 31/790 3/4 /20 24/73 4. '/2°/iS 26/7.9 5 36/915 ~4"/20 28/8.5 5 11/15 43/13.1 8 42'128 - 8 * 49/14.9 10 60/1525 "/20 50/15.2 10 65/19.8 12 72/1830 /20 63/192 12 10.85 5839 Rev AG Updated 07/2019 © 2019 VictauUc Company. All rights reserved. victaulic.com 17 'lo t _au I ii c° victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2/51 mm center line bend radius Length of I Stainless Steel Flexible 11 Outlet 1 2 3 4 5 6 7 8 9 i 10 11 12 Hose Size Bend Bends 1 Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches/ inches/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ feet/ mm mm meters meters meters meters meters meters meters meters meters meters meters meters 31/790 ½/iS 85/26 110/341 130140 160!49 NA NA NA NA NA NA NA NA ~120 100/30 125/38140/43 170/52 NA N.A. NA NA NA NA NA NA 6/91 ½"!15 13.5/4.1 16.O!4.9 18.0/5.5 19.O!5.8 21.0/6.4 N.A N.A N.A N.A N.A N.A N.A ~720 14.0/4.3 17.0/5.2 19,5/5,9 20.0!6.1 23.0/7.0 N.A N.A N.A N.A N.A N.A N.A 48/1220 7/15 155/47 170/52 195/59 20061 21064 220/67 280/85 570QR NA NA NA NA * 4/20 170/5 2 190/58 215/66 245/75 260/79 270/82 300/91 1 NA NA N3_ NA 60/1525 ½!15 21.5/6.6 24.0/7.3 I 27.0!8.2 28.5/8.7 30.0I9.l 31.0!9.4 37.0/11.3 42.0/12.8 44.0!13.4146.0!14.0i N.A N.A /4/2O 23.0/7.0 24.0!7.3 I 28.0!8.5 29.5!9.0 30.5!9.3 3 1.0/9.4 38.0/11.6 42.0!12.8 44.0!13.4 46.0!14.0 N.A N.A 72/1830 17f/15 ,,32.0/9.8__36,51 L.1. 37.5/11.4 40.5112.5. 41.0/12.8 912.8 46.0/14.0 llkl 49.0!14.9152,0/15.854.0 55.0/16.8 3/4720 320/98 325/99 350/107 355/108 4001123 140.5,11i.3 1 0/125 460/140 500/152L51 0/155 520/15 8j53 0/162 NOTES: Values for use with 5.75/140mm straight reducers. How to use this Design Guide: For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends, In this case, the designer may select a design number of bends for the Job and use the associated equivalent length from the design guide to determine the system hydraulics. It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on [lie actual installed number of berets for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 5839 Rev AG updated 07/2019 © 2019 Victaulic Company. All rights reserved. victauliccom 5.1 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses Style AB1, AB2, AB3, A134, A135, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1/33.7mm at 77178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches/mm Imperial/S.I. inches/mm/type feet/meters 31/790 56/81 ½"I15/Stroht ________ 13.8/4.2 ________ 2 ½0/15/9C Elbow 23.5/7.1 36/915 5.6/8.1 ½°/15/Straiylnt - ............ 2 1/2°/15/90 Hhow 25.6/7.8 48/1220 56/81 1/2''/l 5/Straight 234/71 112'715/90 Elbow 307/93 60/1525 5•6/8 . 1 1/2°/156trayht 30.2/9.2 4 15/90 Elbow 35.9/10.9 72/1830 56/81 _____ [-W/15/Straight _ 370/113 4 1/2"/15/90 Elbow 41.1/12.5 31/790 80/1•1.5 ~°/2olStra:glrt ....16.8/S.1 2 3/°/73/93 Elbow ll 5.1 36/915 80/1 5 /20/Strwght nO 2 34'720/90' Elbow I 1 60 48/1220 8.0/11.5 Zt/J!.9... ........................ .27.8/4 ~'/20/90 Elbow 26.6/8.1 60/1525 80/115 W120/Stra:ght 35.7/10.9 /°/20/90 Elbow 33.6/10.2 72/1830 8.0/11.5 - ................/I20/git 435/13.2 4 ~°/20/90 Elbow 40.6/12.2 31/790 11 21161 4/20/Straight 16. 5/5.0 2 /20/90 Elbo4& 17.8/5.4 _______ 36/915 11.2/16.1 /a/20iStraight 19.5/5.9 2 /4'/20/90 Elbow 20.7/6.3 48/1220 112/161 267/8.1 3 4°/20/90, Elbow 27.9/8.5 60/1525 11 2/161 /4/20/StraIght _______ 33/10.3_______ 4 15/20/90 Elbow 35/10.7 72/1830 11 2/16 1 /20/Straight 41.3/12.5 4 ~' /20/90 Elbow 42.2/1 2.8 31/790 140/202 3/4 /20/Strwght 149/45 2 /4"/20/90 Elbow 15.5/4.72 W720/5trai ht 19.4/59 36/915 140/202 Elbow 4'/20i90 196/5. 2 48/1220 140/202 _______ 30.3/9.2 3 14°/20/90' Elbow 29.5/8.9 60/1525 140/202 34 /70/Straight 33.9/10.3 - ½'/20/90" Elbow 34.1/10.4 15/20/Straight 37.5/11.4 72/1830 14.0/20.2 3/4"/20/90- Elbow 38.6/11.7 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. EM 1637 standard fe, safety include, but are not limited to, pressure cycling, corrosion resistance, flow chat acterisitics. vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivaient to the data in the table shown above. In this example, the total number of degrees is 240°, which is ices than the allowable 270°. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. All rights reserved. victaulic.com 19 A~ -C victauliccom p p 5.2 PERFORMANCE - FRICTION LOSS DATA Series AH2 Braided Hose with 900 Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicF!ex Bracket Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1733.7mm at 7/178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches/mm Imperial/SI inches/mm feet/meters 311790 5.6/8.1 ½/15 13.7/4,2 2 j 36/915 5.6/8.1 112715 17.0/5.2 2 48/1220 56/81 12 15 250/76 3 - 60fl525 5/8.1 ...V2"/15 j 33.O/10.1 4 72/1830 5681 1 /15 411/125 4 31/790 8.0/11:5 /4V20 13.6/4.14 - 2 - 36/915 80/115 3i 20 169/52 2 48/1220 [ 8.0/11.5 1/4"/20 27.8/8.5 3 60/1525 115 /0 326/99 4 72/1830 I' 1 2 40.6/12.4 4 31,790 11.2/16.1 /2 /20 13.7/4.2. 2 36/915 11.2/16.1 3,14720 17.0/5.2 2 48/1220 11.2/16.1 . . ~/4'/20 24.9/7.6 3 60/1525 11.2/16.1 '/4'/20 32.9/10.0 4 72/1830 1121161 3/4720 409/125 4 31/790 14.0/20.2 1/4'/20 13.5/4.1 2 ....... .... .. ------ 36/915 140/202 ~/20 168/5 1 2 48/1220 14.0/20.2 __.L_ ..27/7.5 60/1525 14.0/20.2 14'/20 . 32.7/9.9 4 72/1830 14.0/20.2 3/4"/20 40.7/12.4 4 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for Use in wet, dry and preaction systems per NFPA 33, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard icr safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AG Updated 07/2019 02019 Victauiic Company. All rights reserved. victaulic.com 20 \4'tuIac victaulic.com 5.3 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Style AB1, AB2, A134, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Equivalent Length of Maximum Number Length of steel pipe according to of 900 Bends at Stainless Steel Outlet EN 10255 ON 25 3/76.2mm Bend Flexible Hose Size (33,7 x 3,25) Radius mm/inches mm/inches meters/feet meters/feet 31/790 l5mrn/½ 55/180 3 20mrn/ l5mm/½' 36/915 20mm/3/4 48/1220 l5mm/½ .5/279 3 20mm/Ye, 60/1525 15. 10.7/35.1 4 20mm/Ye 72/1830 15mm! - 128'420 4 20mm/1/4 VDS CEILING MANUFACTURERS LIST ABS, AB2, AB7, A810 ,AB11 AB4 AB5, AB8 AMF No specific approval i. 1-lilti Armstrong 2. Knauf Chicago Metallic 3. Lafarge Dipling 4. Lindner Durlum 5. Rigips Geipel Gema-Armstrong H/tl Knauf Lafarge Linder Odenwald Richter Rigips Rockfon Pagos Suckow, & Fischer USG Donn Series AH2 and AH2-CC Braided Hose Series AH2 Braided Hose [EXB Style A131, AB2, AB3, A134, A135, AB7, AB8, Style A131, A132, AB3, AB4, AB5, A137, AB8, and AB1O Brackets AB10 and AB12 Brackets Length of Equivalent Length . Maximum Stainless of steel pipe Number of Steel according to 90° Bends at Flexible Outlet EN 10255 DN 25 3/76.2mm Hose Size (33,7 x 3,25) Bend Radius mm/inches I mm/inches/type meters/feet 790/31 l5mmt/ 1StralghL 1 8/60 2 20.mm/Ye /5trai9ht ................................................ 915/36 'mm/½"/Stright 3.6/11.9 3 :9,m/~14/S!ayht.... 1220/48 15 mm/½' IStraiciht i— 4.3114,0 3 t _mm/__ 1525/60 i1 15m.Y/Str!9 4.1/13.6 3 20mm/3/, /Strai9ht ... . 1830/72 15mrn//."/5traiht 5.5/18.1 3 20mm/aight .. I Length of Flexible Equivalent Length of Hose 1/33.7mm Sch. 40 Pipe mm inches Straight Configuration I: Bend Configuration '790 0.87 ". 2.70 31 2.9 8.9 915 1.00 2.80 36 3.3 9.2 .4220 2.23 L56 48 . 7.3 1 '5.3 1525 2.90 6.5 60 9.5 21.3 1630 1 3.31 7.16 72 109 235 CCCF NOTE Friction loss data is in accordance with. 085135.16 jested at a floe' rate of 114 liters per minute (30 gallons per minute). 10.85 5839 Res AG Updated 07/2019 02019 Victauiic Company. All rights reserved. victaulic.com 21 \4t9uhc victaulic.com p 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Always verify that the piping system has been completely depressurized and drained immediately prior to installa- tion, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. WARNING It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic Company. At rights reserved. victaulic.com 22 Ac_ta_ulic~ victautic.com 7.0 REFERENCE MATERIALS - CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length ft Model Size i m lb Total Load N Max. Uniform Load lb/linear ft N/linear m 31i10 0.8 5.2 23 2.6 36/915 0.9 5.5 25 2.8 40 48/1220 12 63 28 31 46 60/1525 1.5 7.0 31 3.5 51 72/1830 6 77//.j/1. 34 79 57 1.8 Series AH2 Hose with 48" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N lb/linearft N/linearm 31/790 61 T 27 15 22 0.8 36/915 09 6.4 29 1.6 23 48/1220 7.2 32 1.8 = 26 60/1525 15 7.9 35 2.0 29 72/1830 8.7 1.8 . 39 2.2 * 32 Total Load is defined as the sum of the weights of the following: water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Actual Length Mm. Allowable Uniform Load Suspension System 1 ft/rn lb/linear ft N/linear m 75.7 Direct Hung Intermediate 120 181.0 Heavy 160 2417 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. 10.85 5839 Rev AG Updated 07/2019 © 2019 Victaulic company. All rights reserved. victaulic.com 23 \j'tauIicf victauUccom 7.0 REFERENCE MATERIALS - CHARACTERISTICS (CONTINUED) Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends / /—— / H bend odus L d timum \ OR OR bend rad/is Mini L 4 r1'n/ NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. i-VicFlex-Af31-A[t2-A1310 i,.Vic f lax., A if 3 l-VicFkno-AB-1. i-V ic F lox-A 8 7 i-Vc7lox-uiBl2 V/F lox A BRA l-Vic'.Floa-ABMM User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Viclaulic products for a particuiar erro-use application, in accordance with industry to be installed in accodarice with current Victauhic installation/assembly instructions, sluridnids and protect specifications, and the oppli,subte building cud irs use related Victaulic reserves the right no nlnirirge product specifications. designs and standard regulations as well as Victaaiic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. irrstructionrs. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Vichaulic employee, shall be deemed to alter, nary, supersede, Reference should always he models lVICFLEX-ABI-AB2-AB1O, l-VICFLEXAB4. or waive any provision of ho tauli Company s standard corncitinrrs or sale. installation I VICFLEX A87 or I VICFLEX AdS for lire product you a e installing. Ha r books are guide, or this disclaimer, included with each shipment of Victaulic products for complete installation and assembly Intellectual Property Rights data, and are available in fiRE formal on our websitn at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any nralvrrol, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulnc or any or its subsidiaries or affiliates covering such use or design, .'m ova recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Viclaufix and all other Victaulic marks are the trademarks or registered trademarks nf property right. The terms "Patented' or "Patent Pending" refer to vosign or utility patents Vorlaule Company, aeit/,rr its affiliated enititiirs. in lhn U.S. unit/or niihei countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.85 5839 Ron AG Updated 07/2019 © 2019 Victauhic Company. All rights reserved. victaulic.com 24 _1uA_C_ta_U1ie