Loading...
HomeMy WebLinkAbout2100 COSTA DEL MAR RD; 2013; FPC2020-0053; PermitF* IItl1i12s)4i (ity of Carlsbad FiiPr1miit Print Date: 11/05/2020 Permit No: FPC2020-0053 Job Address: 2100 COSTA DEL MAR RD. # BLD 2013, CARLSBAD, CA 92009-6823 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2165900100 Track #: Applied: 03/26/2020 Valuation: $569,282.40 Lot #: Issued: 05/01/2020 Occupancy Group: Project #: Finaled Close Out: 11/05/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: OMNI HOTEL - CHOPRA CENTER: SPRINKLER TI (116 HEADS) Applicant: FPContractor: PARAMOUNT FIRE SYSTEMS INC PARAMOUNT FIRE SYSTEMS INC JAMES CHENEY P0 BOX 713194 8069 WING AVE SANTEE, CA 92072-3194 EL CAJON, CA 92020-1245 (619) 562-6247 (619) 562-6247 FEE AMOUNT FIRE NFPA 13 System > 100 heads (includes 1 riser) $858.00 FIRE Reinspection (per inspection) $193.00 Total Fees: $1,051.00 Total Payments To Date: $1,051.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FFC2zo -O03 rf-=D[70 Worldwide www.tyco-fire.com Contacts Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2NPT TY323 ......Pendent 5.6K, 1/2 NPT Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratones, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi"2 (80,6 LPM/bar112) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200° F (93°C) 286°F (141°C) JANUARY 2013 r - Finishes Sprinkler: Natural Brass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector, can be provided on special request. ESCUTCHEON PLATE 1/2° 7/16 (11,1 mm) Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN I 7/16 _ \ I (11,1 mm) I NOMINAL 50,8 mm) MAKE-IN 2 L 'J [V/ 1-3/8 8 (50, mm) __ I (34,9 mm) WRENCH FLATS I 1/2 NPT** DEFLECTOR* 4 - Bulb 5 - Compression Screw STYLE 15 or 20 RECESSED ESCUTCHEON 2-7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Crfferia The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. llevsfcillll2ff©iv The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) - 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) FLUSH 3/8±5/16 (9,5±7,9 mm) z"d \ t I MOUNTING SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) .TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8 DIA. - (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. FITTING (57,2 mm) 5/16±1/4" 1/2" (12,7 mm) (7,9±6,4 mm) I FLUSH 717, MOUNTING 'j I SURFACE \ (32 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TVFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N* 77 - XXX - X - XXX SPRINKLER TEMPERATURE L7 FINISH RATINGS SIN 370 5.6K UPRIGHT (1/2 NPT) 1Y313 371 5.6K PENDENT (1/2 NPT) 1Y323 Use suffix I' for ISO 7-1 connection; for example, 77-370-4-175-I 1 NATURAL BRASS 4 SIGNAL WHITE (RAL 9003) 3 PURE WHITE (RAL 9010)** 9 CHROME PLATED Eastern Hemisphere sales Only 135 135°F (57°C) 155 155°F (68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) TABLE A SERIES TV-FRB UPRIGHT AND PENDENT SPRINKLERS - PART NUMBER SELECTION - crderffflvg Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (SIN), K=5.6, (Upright or Pendent) Sprinkler Quick Response, (specify) temperature rat- ing, (specify) finish, P/N (Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Perinbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. tuccv TEFLON is trademark of The DuPont Corporation. STYLES 920 AND 920N Victaulic MechanicalTT Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. (Th / STYLES 920 AND 920N j r ) STYLE 920 CROSS PATENTED MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "1" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. "Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listine of services which are not recommended. CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/345OkPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: CI-.,I,-, (V)Cl -,.-,,-1 C-,I.-, 0Y101,I k-. I.,.., 2 x 'A (a) 920N 500 1.50 2.00 2.53 1.61 5.35 32 50 15 3450 38.1 51 64 41 136 1.5 - 1/4 (a) 920N 500 1.50 1.97 2.53 1.61 5.35 2.75 3 20 3450 38.1 50 64 - 41 136 70 1 5 - 1(a) 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 30 25 3450 38.1 47 64 - 41 136 70 1.4 - 1 114 t' 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 3450 44.5 1 52 70 76 41 136 76 1.7 1.5 1 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1.7 1.5 2112 x I.? 920N 500 1.50 2.21 2.74 1.82 5.64 2.75 3.0 65 15 3450 38.1 56 70 - 46 143 70 1.4 - 3/4 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 38.1 55 70 - 46 143 70 1.4 - 1(a) §U 920N 500 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 3450 38.1 52 70 - 46 143 70 1.4 - 14 t (a) 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 92N 32 0 3450 44.5 58 76 83 46 160 76 1.7 1.5 1½ 1(a) U 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 7 1 • " (a) 920N 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 - 57 164 81 1.8 - ~ (a) 920N 300 1.50 2.19 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 57 164 81 1.8 - 1(a) cION 300 1.50 2.07 2.75 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 - 57 164 81 1.7 - 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1½ (.3) U ) 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 1,5 () U 920N 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 15 3450 38.1 64 78 - 58 156 70 1.6 - ~(a) U 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 - 58 156 70 1.6 - 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 - 58 156 70 1.6 - 1 ¼ (a) (U 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 156 76 1.8 1.8 1½ (a) t-1 920N 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a) U 920N 500 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 23 2.1 3½ 2 920N 500 2.50 3.00 3.75 2.44 6.72 3.88 ( 3.8 90 50 3450 63.5 76 - 95 ) 62 171 99 - 1.8 TABLE CONTINUED ON PG 3 1 .t,,r ,,ç i ,,,,i ,-Id fI- ,-,,,i,, A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: Has a Corrosion Resistance Ratio of 1.0 Has a Pressure Rating of 300 psi Is Lighter Weight Than Schedule 40 Is Approved by Factory Mutual and Listed by Underwriters Laboratories Is Produced in Accordance to ASTM A-135 and A-795 Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves Is Produced From Steel With Excellent Properties of Strength and Threadability Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 1 1.461 1.083 70 11/4 2.070 1.418 51 11/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1 1.00 1.00 11/4 1.00 1.00 11/2 1.00 1.00 2 1.00 1.00 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, Chesterfield, MO 63017 contact your salesperson today at C®US Q BULL. MOOSE TUBE CDPdIPANV (800) 325-4467 (800) 325-4467 or (636) 537-2600 LISTED FAX: (636) 537-2645 in the USA, or from Canada www.bullrnoosctube.com call (800) 882-4666 A (CAPARO company e-mai!:sa1esbu1lrnoosetube.coni ______ APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the tight to change product specifications without notice and without incurring obligation. 8/08 Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 iTT' x Hominat Size Dimension A Approx. Wt. Eiith - k Irw g 14 0.69 0.09 0.81 0,14 004 0.95 0.21 1.12 0.31 1.31 0.50 1 150 0.19 10 -; 0 1.19 12 - 0J4 1.94 131 2 215 2.43 210 413 3 3.08- 6-31 40 il 73 212 4 3.19 11.03 6 50 £I3 2S,98 , -- U$Th APPROVED %MÜU4 *SW#W4WtOt ( I 1 Dimensional: Fttirgs: ASME 816.3 Unions: ASME B1639 Bush hgs/Plugs: ASME B16.14 Material: ASIM 4-197 Golvonizing: ASTM Al 53 (Hot Dip Galvanizing) Threading*; ASME 8L20.1 Pressure Ratiig: Fittings: ASME B 16.3 Unions: ASME BI 6.39 Bushings/Plugs: ASME B 16,14 Pressure Testing: AI malleable iron Fittings ore tested For through wail porosity using an air under water process. Agency Approvals: All malleable iron Fittings and unions are UL Listed. and FM Approved. Brush •Stando1 uhte:ding per BS 21 ovoiksble upon reqvu http ://www.anvilintl.com/ProductSearchPrintProduct.aspx?lid=43 81 1/8/2014 Print Page 2 of 5 I:11i1uiI[cII11 Malleable Iran Screwed Fittings - Class 150 REDUCING tTEE _______ Cimension _______ Nominal Size '1' B ' Approx. W1. Each t n") 1 arsrl t. 9tpI Ii 0.91 098 0.24 ______ .04 l.U' 1.03 027 42 ____iF 1.22 1.20 0.31 049 1.36 1.36 1.26 r!,,i 1 70 127 _________ j1.1 108 0.36 /4 ______ .i2 1.12 1.13 0.39 26 20 1.20 127 0.43 1 145 1.4 1.3/ 0.62 _- 14 1 150 1.18 150 0.63 6 ?" - ThV TTf 1 4U ½ r "iv 145 - 0-56 I 1.510 1 13 .50 5 0.6/ 126 120 16 053 14 W 131 13l 1.45 t 0.61 -___I_ 1 1.50 1 '45 1.50 [ 0.11 I, Tt T 1.26 W .3 0.61 ThT 147 1 It [W 1 /6 1 1.6) 1.61 1 156 t 0.94 __ 1 1.t0 1.80 1.65 1 LO? -.,I- __ 2 2.02 2.02 U3 1.45 Dimensional: Fittings: ASME 816.3 Unions: ASME 816,39 Bushings/Plugs: ASME 816.14 Material: ASIM A-I 9 Galvanizing: ASTM M53 (Hot Dip Galvanizing) Threading': ASME 81.20.1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME:816. 14 Pressure Testing: All malleable iron linings are tested For through woll porosity using on air under water process. Agency Approvals: All malleable iron fittings and unions ore UL listed and FM Approved. * Briish Standard threading per BS 21 ava1óblo upon 'request. REDUCING TEE Remind Size ______ Dimensions Approx. WI h 6(n$ 6i1wd 1bL(ke) 167 '0 1,75 1.53 115 095' is 4' 14 145 1.31 1,62 0./5 3/t A 1 153 1.45 1.6/ 0.87 ___ _____ 6 1 114 1./9 1.62 1,15 100 - 4 26 "131" 0,74 .6 /$ Tt- 0,8r' 1¼ 3? 1 Th 1 c 61 1/5 __ 108 14 1.26 1.26 1.44 018 14 134 1.34 LW 0.34 44 14 145 1.45 162 0.92 114 32 1 1.513 1.58 ____ 167 47.42 ____ .04 W 'Ti 182 1498 A - Lno APVft.OVD http://www.anvilintl.comfProductSearch/PrintProduct.aspx?lid=43 80 1/8/2014 Print Page 4 of 5 Malleable Iron Screwed Fittings - Class 150 NOMIR01 %e A B C Approx. WI. (och 7 rri) n fru7) Li 94 1.66 1.94 124 16 50 1,26 1,69 0114 76 U 194 1S 194 129 1 1 1.94 1.67 6 i8 1.23 I 1A 1 4 152 145 1/5 104 I 1.65 1.58 1.80 Th t"' +i 44.93 IV 1 45 496 2.10 L9 1.87 "iir Ii.? T8V 423 4 1.94 92.9 2 2.10 -v---- 5 1,41 46 i I I 44 --_ 1,04 116 t 65 US 4972 fr 1.82 ''1.2"1 fl8 F 8" 225 189 1 'T' 2.25 1.9/ 2.25 'Th --_ - I 1.81 1.75 1,8/ 1.39 97 4445 26 2 2.25 212 2,25 7.00 )I4 3? 3 i/ ...4L. 'W"TV TW" TT "TW" 2 225 210 225 209 'T 1.73 -T6 -5 2.02 1.9 2 49 _______ "1W 1.90 1.82 2)0 1./1 156 2.02 94 2i6 -m"- 1.88 216 ii" 221 2 225 - "ii 188 b3 I '111"' "16r 173 1123 'Tif" i 78" "190 1-90 IV p 202 202 & 21? Th 160 L60 ' 239 315 A, koft-11 Nominal DhRnsion omiric &ze A 1 8 - Approx. WI.Each ni mn'i9 6 9'vnl Li Li (rr9 LBs_(8s9 1/4 /4 2.132 Oil 7W" 1 1 1.87 1.81 7.37 2.84 216 256 U 2.04 2.04 2.45 3.09 1 2 7)6 7 1 329 2 2 2.52 4 i 1.09 Li 4 3,3 '6 T7 3 so Tm 2.66 9 3 ,1 2.17 71T' I'fl" 1 1 2.29 2.29 2.80 4,45 2 2.52 2.52 2.89 4.90 24 293 2.8 569 - , 'r "r ""yr 1: 52 13 Q AO 4 1 3.30 3.3J http://www.anvilintl.comlProductSearch!PrintProduct.aspx?lid=43 80 1/8/2014 ic® urno APP%OVEf For j,1. 44Ai 4bW a WWW. .V4IT Print Page 2 of 3 U <EF;~~3- D Malleable Iron Screwed Fittings — Class 150 tI'1! :fiI1!jI 714 Dimension A Approx.Wt. Eoth k4) 0,69 - 0,06 V4 0' 010 Va 0.95 0 is 3 14 112 - 022 Va 11 0.3.8 1 1.50 057 1% 1.15 0,87 22 1½ 1,94 116 2 2.25 1.81 2½ 2.111 323 3 3.08 422 4 3.19 - 8.41 6 5.13 19.96 Dimensional: Fittings- ASME 616.3 Unions: ASME 616.39 Busbin9s/Plugs: ASME 616.14 Materiel: ASTM A-i 97 Galvanizing: ASTM A-153 (Rot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME B 16.3 Unions: ASME 616.39 Bushings/Plugs: ASME B 16.14 Pressure Testing: All malleable iron fittings ore tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions ore UL listed and FM Approved. British Siandord theodng per BS 21 avoilable upon requ. http://www.anvilintl.com/ProductSearchlPrintProduct.aspx?lid=4370 1/8/2014 Print Page 2 of 3 $jf j Malleable Iron Screwed Fittings - Class 150 011 Nominal Si-A Dimensions Approi. WI Each B X 074 016 0.08 3Ax4 081 0.85 011 33 0.88 0,90 013 0.91 0.98 016 2490 103 0.19 33 1.12 1.13 0.28 - x 129 122 029 1.18 Ito 035 I s 1.26 136 0+42 1 _____ Thi 1.45 0.47 331 1 :4 0½ 1.34 1.53 0.54 I r5 1,45 1.62 062 l 158 161 073 I 138 165 065 1+ 1, 5? 1,75 0.74 3 3 4 V4 xi 1.65 1 1.80 0.88 I 4 1.82 1.88 1.03 7x14 1.50 1.89 0.93 1 33 1 1.40 197 1.04 2x I 113 2.02 1.28 334 3 2xi5 2m 1.36 2x1½ 2.02 2.16 1,51 / 11 r1 c&* two AppRovr -I:-) 'F&•'..- FL''"'3. - w4ar 3t.b4CSaL' f4lO14,, 3 Fkfl F Dimensional: Fillings: ASME 816.3 Unions: ASME B 16.39 Bushings/Plugs: ASME 816.14 Material: ASTM A-I 97 Galvanizing: ASTM Al 53 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME 818.3 Unions: ASME 816.39 Bushings/Plugs: ASME B16,14 Pressure Testing: All malleable iron fittings ore tested For through wall porosity using an air under water process. Agency Approvals: All malleable iron fittings and unions are UL listed and FM Approved. British Sadord threading per BS 21 available upon request. 0enions Nominal Size B Approx. WI. Each t (wr h 90 F' 2 xl i 6 151 220 2 x2 239 260 255 3x? 252 289 335 3x2 263 299 412 4 14 501 4n3 3D 360 665 http://www.anvilintl.comlProductSearch/PrintProduct.aspx?lid=43 71 1/8/2014 Print Page 2 of 3 Malleable Iron Screwed Fittings — Class 150 • .D1INUht[rU Nominal size OlmEnsion A Approx. Wt. Eoth . k r ¼ 0.96 - 0.05 ¼ 106 0.08 ¼ 1.16 0.12 ½ 134 0.11 0.21 ¼1.52 1 1.61 0.43 1% 1.93 0.65 3? 029 1¼ 2.15 0.88 2 2.53 135 2¼ 2.88 2.3.3 3 3.18 3.34 4 349 5,59 WflD APPROVED Fc Ijo cot* U, I VM w r4Lm -• e MATERIAL S rJ'1 [f 11,1 ' Dimensional: Fittings: ASME 816.3 Unions: ASME B16.39 Bushings/Plugs: ASME 816.14 Material: ASTM A-197 Galvanizing: ASTM A153 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME B16. 14 Pressure Testing: All malleable iron fittings are tested For through wall porosity using an air under water process. Agency Approvals: All malleable iron Fittings and unions ore UL Listed and FM Approved. * British Sondord thfeoding per BS 21 avasloble upon fequr. http://www.anvilintl.comfProductSearch/PrintProduct.aspx?lid=43 74 1/8/2014 Print Page 2 of 3 q*E7~/F~NVC Malleable Iron Screwed Fittings - Class 150 Nominal size Dirnenôn A Appox. WI, roth A 1tO 00/ ;ix 14 1,13 0.09 X IA 1.13 OJO 1.2 1.25 0.13 4x35 1.25 0.14 COO 1,44 0.18 110 T'6 1.44 0.20 1.44 0.21 1.44 022 1x½ 169 0,34 0 I 1.69 0.36 I x 1h 2.06 0.47 2.06 0.51 Wxi 2.06 0.51 1½ 2.31 0.42 Ix 23 046 - 231 0.73 DimcriioruI: Fittings: ASME 816.3 Unions ASME B 16.39 Bushings/Plugs; ASME B16.14 .MterjoI' ASIM M97 Galvanizing: ASTM A-153 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME B16,3 Unions; ASME B16-39 Bushings/Plugs: ASME 816.14 Pressure Testing: AU malleable iron linings ore tested for through wall porosity using on air wider water process. Agency Approvals: Al! malleable iron linings and unions are U.1 Listed and FM Approved. * Brsh Stondord thfooding per B$ 21 avaIobIe upon requeI. Honiircl Size Dimension A Approx. WI. (cdt - ti th 2x 2.31 0.94 2 x §1 2.83 0.99 21 2,81 1.03 2.11 1.17 1.25 21h x W 32 5 1.81 3.25 1.90 3.25 2.04 3 x 1 369 748 35 1V 3.69 255 3x11' 16i 261 3 i 2 3.69 2.78 3 x N. 3.69 3.23 433 4.43 433 481 3 4.33 5.29 http://www.anvilintl.comlProductSearchfPrintProduct.aspx?lid=43 79 1/8/2014 Print Page 2 of 3 Iku1ci < CSP F--/~ Malleable Iron Screwed Fittings - Class 150 LMN *PPOVEO wow, 4D - wa wnratatxct1 c. -, - Nominal Dine ions Approx. A B C Size Wt.Each v) bItiar) 1b5t1 sow 044 0.28 0 <5 0.04 71 5 ½ 048 031 044 0.06 C ½ 0.56 0.38 0.56 0.08 lb ~ 4,117 ON cored 14 0.63 0.44 0.63 0.13 cored .. 1 0.15 0.58 0.81 0.20 r 1 .OIu 1½ 0.80 0.56 ON 21077 ):?7 63 0.32 2 Cored 4 1½ O,S3 0,62 113 0.43 7)5 0,29 Cored 2 0.88 0,68 Ui 0.67 Cored 21h, 107 0.74 150 1.11 Cored 3 113 1.53 U Be nU 4 1.22 1.00 - 2.11 BrNu1 6 140 1.25 - 4.00 MATERIAL SPECIFICATIONS Dimensional: Fittings: ASME B16.3 Unions: ASME B16-.39 Bushings/Plugs: ASME B16.14 Material: ASTM A-i 97 Galvanizing: ASIM A-153 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME B 16.39 Bushings/Plugs: ASME B16,14 Pressure Testing: All malleable iron fittings are tested For through wall porosity using an air under water process. Agency Approvals: All malleable iron Fittings and unions ore UL listed and FM Approved. British Siondor1 threading per BS 21 aviIobIo upon request, http ://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=4378 1/8/2014 Print Page 2of3 Malleable Iron Screwed Fittings - Class 150 pp-j-, g W 1LiI1 ffQminul size Dimension A Approx. WI. Each 0.53 0.03 063 0.05 OR 0.74 0.07 5' 0.87 0.11 14 097 0.18 116 0.30 1 1/4 1.28 0.44 1.33 035 40 2 1.45 0.85 214, 1.10 1.49 043 3 130 2.20 .....______ 353 1.90 3,0 4 IN 3.79 6 255 87? 1 19 - Sd isi S o4 tB&kotd G.tu1J. I I w1 APPROVED J ............... 0)' . I Dimensional: Fittings: ASME 816.3 Unions; ASME 816,39 Bushings/Plugs: ASME B1&14 Material: ASTM A-197 Galvanizing: ASTM Al 53 (Hot Dip Galvanizing) Threading: ASME 81.20.1 Pressure Rating: Fittings: ASME B 16.3 Unions: ASME 816.39 Bushings/Plugs: ASME 816,14 Pressure Testing: All malleable iron fittings ore tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron Fittings and unions ore UL Listed and FM Approved. ' Btmh Siondrd Ihøodin9 per BS 21 avIthIe upon request http://www.anvilintl.comlProductSearchlPrintProduct.aspx?lid=43 73 1/8/2014 Fig. 200 - "Trimline" Adjustable Band Hanger C®US USTED Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21h" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTm Fig. 200WON. Order By - Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31A 25A 400 11 3/4 3/8 8mm or 10mm 31A 2½ 400 11 1 3/8 8mm or 10mm 3% 26A 400 12 11/4 3/8 8mm or 10mm 33/4 2/8 400 13 1½ 3/8 8mm or 10mm 37A 27A 400 14 2 3/8 8mm or 10mm 41h 3 400 15 21h 3/8 10mm 55A 4½ 600 27 3 3/8 10mm 57A 4 600 29 31h 3/8 10mm 73A 51/4 600 34 4 3/8 10mm 73A 5 1000 35 5 1/2 12mm 91A 61/4 1250 66 6 1/2 12mm 10½ 6Y4 1250 73 8 1/2 12mm 131A 83/4 1250 136 Page 55 OFFICE/MANUFACTURING FACIUTY. 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599. FAX' 951737.0330 A CUSTOMER SERVICE • 800.786.5266 www.tolco.com H Fig. 25 - Surge Restrainer Size Range - One size fits 3/4' thru 2' pipe. Material - Steel Function - Designed to be used in conjunction with TOLCO Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the bank hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed qnly when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 C®US LISTED OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE . CORONA, CA 92879. PH: 951.737.5599 • FAX: 951.7370330 CUSTOMER SERVICE . 800 786.5266 www.tolco.com Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions 'Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 -RocLStiffener Size Range - Secures 3/8' 7/8' hanger rod Material - Carbon Steel Function - Secures channel to hanger rod fo tical seismic Approvals - Underwriters Laboratories Listed in the U Canada (cUL). Included in our Seismic Restraints Cat app Component of State of California OSHPye1iL us USTED Seismic Restrai stem Finish - EticrGalvanized Not _railable in HDG finish or Stainless Steel materials. örder By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - AllThread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod ir 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions 'Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt.I100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE.. CORONA, CA 92879. PH: 951.737 5599 • FAX: 951,737,0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 113 - Standard Hex Nut Fig. 114 - Heavy Hex Nut Size Range - Sizel/4" thru 1V2" Size Range - Sizell4" thru 11/2' Material - Carbon Steel Material - Carbon Steel Finish - Plain Finish - Plain Note - Available in Electro-Galvanized and HDG Note - Available in Electro-Galvanized and HDG finish finish or Stainless Steel materials, or Stainless Steel materials. Order By - Figure number size and finish ....... / ...... 1 Dimensions Weights Dimensions • Weights Width Width Width Width Rod Across Across Approx. Rod Across Across Approx. Size Flats Points Thickness Wt./100 Size Flats Points Thickness wt.iioo 1/4 7/16 1/2 7/32 7 1/4 1/2 37/64 15/64 1.2 5/16 1/2 37/64 17/64 1.1 5/16 9/16 21/32 19/64 1.7 3/8 9/16 21/32 21/64 1.6 3/8 11/16 51/64 23/64 3.1 1/2 3/4 55/64 7/16 37 1/2 7/8 11/6 31/64 6.5 5/8 15/16 1 /32 35/64 7.3 5/8 11/16 1/M 39/64 12,0 3/4 11/8 1 /16 41/64 12.0 3/4 11/4 1/ 47/64 19.0 7/8 1/18 1/ 3/4 19.0 7/8 121/32 55/64 30.0 1 11/2 1/4 55/64 28.0 1 1/ 11/8 63/64 43.0 1 /4 1/ 2/ 1 /16 54.0 11/4 2 2/16 1/32 79.0 11/2 21/4 219/32 1 /32 94.0 11/2 2/8 2/4 t/32 131.0 Fig. 115 - Flat Washer Fig. 117 - Lock Washer Size Range - Sizel/4' thru 11/2 ' Size Range - Sizell4' thru 3/4' bolt Material - Carbon Steel Material - Carbon Steel Finish - Plain Finish - Plain Note - Available in Electro-Galvanized and HDG Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials, finish or Stainless Steel materials. Order By - Figure number size and finish Order By - Figure number size and finish Dimensions .Weights Dimensions -Weights Rod Size Outside Diameter Approx.Wt./100 Rod Size Outside Diameter Approx.WtJ100 1/4 3/4 .7 3/8 11/16 .6 5/16 1 1.5 1/2 7/8 1.3 3/8 11/8 3.9 5/8 1'/I6 2.4 1/2 1/4 7.7 3/4 1'I4 40 5/8 1 /6 7.3 3/4 2 11.0 7/8 21/4 19.0 1 2I4 22.0 1V4 3 26.0 11/2 31/2 39.0 Page 63 Office/Manufacturing Facility. 1375 Sampson Ave Corona, CA 92879. Ph: 951.737.5599. Fax: 951.737,0330 Customer Service • 800.786.5266 (*3 www.tolco.com '0 •' CUS WOOD Pipe Hanger Approvals MW 1I 8007957 GST 10 3/8 Vertical CPVC 11/2 300 1-112" 8020957 SWG 10 3/8' Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST 20 3/8 Vertical 21/2" 850 11/2 4 1475 11/2 8068925 GST 20-SS 3/8" Vertical 2-1/2" 850 1-1/2' 8010957 GST 30 3/8 Vertical 4 1500 1-1/2' 4 1475 1-112, 8009925 GST 25-380 3/8" Horizontal 4" 1500 1-1/2" 8022925 SWG 25-380 3/8 Honzontal 31/2 4 1500 11/2 8021957 SWG 20 3/8" Horizontal 2-1/2" - 3""" 1050 1-1/2" 8073925 SWG 20-SS 3/8 Honzontal 21/2" 850 11/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2" 4' 1475 1-1/2" 8141957 .SH-GST3O 3/8" 17° Angle off Vertical 4" 1500 1-1/2" 4" 1475 1-1/2" STEEL. Pipe Hanger Approvals GiL11 M90 ü' im Th? j- 8038957 8038957 DSTR 1 3/8 Vertical 4 1500 035 4 1475 105 8037957 DSTR 1-1/2 3/8" Vertical 4' 1500 035" 4" 1475 .105' 8039957 DSTR 516 3/8 Vertical 4 1500 037 4 1475 105 8045957 DST 516 3/8' Vertical 1500 .188" 4" 1475 .188' 8046957 TEK 50 3/8 Vertical 4 1500 250 4 1475 188 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4' 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH DSTR 1 3/8 17 Angle off Vertical 4 1500 035 4 1475 105 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 8153922 XP 35 3/8 Vertical 31/2" 1250 060 4 1475 8294922 SXP 20 3/8 Vertical or up to 45 2 750 027 2 635 029 8295922 SXP 35 3/8 Vertical or up to 89 3-112" 1250 060 2 635 029 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060" C 9'O,IM PMur/°a O - ri,o '"'. ,. . Pipe Hanger Approvals Part N a 0 Model 0 e Rod Mount UL Max UL Test UL Mm FM Max FM Test FM Mm Size Direction Pipe Size Load (Ibs) PSI Pipe Size Load (Ibs) PSI 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC2O 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8 Vertical 21/2 850 Pre-Pour Structural @3000p51 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC !s 35 PCF (Ibs/ft3) SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/7 SWG 25-380 Maximum pipe size in wood limber or joist allowed by UL is 4 "SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/7 SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 7 Sammys° and Truss-T Hanger° are registered trademarks of 11W Buildex and Illinois Tool Works, Inc. C 2008 11W Bcciideo and Illinois Tool Works, Inc. REV 0308 SSS40 UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weight of water tiled schedule 40 pipe plus 250 pounds S.4MMYS' SAMMYS" ex www.itwbuildex.com 800-BUILDEX