Loading...
HomeMy WebLinkAbout3248 LIONSHEAD AVE; ; FPC2019-0196; Permit4lltyof PERMIT REPORT Carlsbad Print Date: 12/02/2020 Permit No: FPC2019-0196 Job Address: 3248 LIONSHEAD AVE. CARLSBAD, CA 92010-4713 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2218811700 Track #: Applied: 08/15/2019 Valuation: $2,498,567.64 Lot #: Issued: 09/04/2019 Occupancy Group: Project #: DEV2018-0069 Finaled Close Out: 10/01/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: inspector: Plan Check #: Final Inspection: Project Title: TESLA-SERVICE STATION Description: TESLA -SPRINKLER. MONITORING WITH 4 DUCT DETECTORS FPContractor: RIVER FIRE AND SECURITY INC 8920 ACTIVITY RD, # STE SAN DIEGO, CA 92126-4458 (858) 752-6250 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov SUBMITAL BOOK FOR: 6/20/19 TESLA 3248 LIONSHEAD AVE. CARLSBAD, CA 92010 RIVER FIRE AND SECURITY 8920 ACTIVITY RD. STE. J SAN DIEGO CA 92126 C 1 896646 CUTSHEETS AND CSFM LISTINGS FOR: IFP-75 CONTROL PANEL CELL-CAB-SK CELLULAR COMMUNICATOR IDP-MINIMON INPUT MODULES IDP-PHOTO SMOKE DETECTOR IDP-PULL PULL STATION FPC20I9-0196 3248 LIONSHEAD AVE TESLA - SPRINKLER MONITORING WITH 4 DUCT DETECTORS DEV2018-0069 2218811700 8/15/2019 FPC20I9-0196 ,,00_ "53 Honeywell Farenhyt'-' Sene's THE POWER OF CONNECTED IFP-75 / IFP-75B Intelligent Fire Alarm Control Panel The IFP-75 (red) and IFP-75B (black) are intelligent add-essable fire alarm control panels (FACP) and are direct replacements for the IFP-50 FACP The IFP-75 has one signaling line circuit (SLC) Loop for connecting addressable detectors, which can support 75 System Sensor 'IDP/SK sensors and 75 DP/SK modules or 75 Hochiki SD devices per loop.The total point capacity for IDP and S.< devices is maximum of 150 points per panel Using SD devices, the total point capacity is a maximum of 75 points per panel The LFP-75 has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one Larger building, or multiple independent buildings The SK-NIC Network Interface Card is used to network panels together. Copper wire or fiber optic cable connectivity can be used within the same networked system The LFP-75 has a built-in dual-line digital and IP communicator with an optional cellular communication module, form-C trouble relay, and two programmable form-C relays The I FP-75 has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert. The IFP- 75 supports a variety of devices, including RA-2000. RA-1000 or RA-100 remote annunciators. 5324 serial/parallel printer interface modules (for printing system reports), RPS-1000 power modules. and LOP. SK, SWIFT wireless or SD devices. Network support for UI) to 32 Sites Built-in suppor: for up to 75 iDP/SKdotec;Iors ,iocf 75 1,DP/BK or '5 3D Sf_C ci cvi cv Feu, i's LCD di O'itli 't) cI'liOOli.r" i,'sr i;,ii,itfc ii' . isO or blink birit Can be siirfnirp nr flush mounted Built-in USB irit'srFic or convsniCnt 5011 cluck progremniiJig Prncli'aooahh' clt scthnq for Daylight Sii'.'!nq firii-n Ji rnpFtnirt auto firoqroioniricj l'S,ifirO for cosy proiinmininq Ri lit - in di ia rholle liii, cliqitat uteri OOilii niiricrtcir/ trci i, ci itter ID\CT) ivltfi IP olld optiorsil counter t'clnotoglcss Not'; ork cqrd atlo'q cc pp ci r ri-s LV Di cnnvct'rii 'situ ri 'lull -rn';d 0r,.. ITIOdU (4 icr corincvtion opliLiil Convenient bold )ciiirI,ibi- (irnl,','a ri Supports Ii: I (I Ciii SIVIFT 'circus rJLILOiVci''E5. Each jcrto','/ccy Can 'hil'?V U) to 'IF ',•''irlccs de'.'iCt Suqpcni ts Clac. B (St'- la 4) mid Licis -; It Cl or Slyt 7) con cjiirtori br 3vC ond SRI_IF BuRt-ifl [JAI.. yr1cillOnt7,5tiOii for dIr.rq frill ItM3ECQ Sysrero j 'isur j:'rf Wheetn, Is Pport , ''ruts to t"t(ul lr,Ili)ii by pill fl' 'i 11'' rino CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 010, LISTING No. 7165-0559:0503 Page 1 of 2 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneyweIl.com DESIGN: Silent Knight Model IFP-75, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). Model IFP-75 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 SeriallParalell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerface Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16WX10HX6D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: 120VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CELL-CAS-SK Honeywell FarenhytT" Series THE POWER OF CONNECTED CELL-CAB-SK / CELL-MOD CeLlular Fire Alarm Communicator The CELL-CAB-SK and CELL-MOD are cellular communication options for the next generation of Honeywell Farenhy: series addressable fire alarm control ponds These cellular options meet UL 864 requirements for sole, primary or backup path communications. 4larmNet provides nationwide digital cellular network coverage for a UL listed connection between the CELL- CAB-SK / CELL-MOD and the central station The CELL-CAB-SK houses a GSM (cellular) communicator inside a meLd cabinet with lock and key and includes external antenna that mounts on top of the unit The CELL-MOD houses the GSM communicator inside a plastic enclosure that may or may not require an external antenna depending on the installation environment, Both models can be remotely mounted away from the fire dorm control panel vie o 4-wire bus for optimum reception. The CELL-CAB-SK / CELL-MOD can serve as the sole communicalions path for compatible Honeywell fire alarm control panels with programmable supervision time of 1-60 minutes, CELL-MOD Clliilar carri romps in Ill R64 inrl NFP 77 a plastic case or metal code compliant for enclosure with lock solo primary or and key backup coon U 11 icat io tic Orjtioiiai. aterriuti antcnnas Irirli rise Quality of Service (OOS) 'Jivrjriostics via AlarrriNat ,vhicli :c)Iivsys viti co morn LI maca to nforlustion ncliidinq jlien rnessntjes aro rm.'ceived, signet st ronqth and IlIeSsage p1511 us .'.d Prograniniable supervision time. from 1 to 60 minutes Provides full data rePorting using Contact ID lot mat Accounts csn be eaiIy rnenged through on-line iimeilisjCiiiOnt tools i4.-wire but, connection rullouvs renmoto nmeliuttitirj for 1)51St rsceptiuii CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0503 Page 1 of 2 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett©honeywell.com DESIGN: Silent Knight Model lFP-75, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). Model IFP-75 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerface Card SK-NIC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16'WX10'HX6'D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: I20VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and it This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installa:ion instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt DSILENT KNIGHT by Honeywell Addressable Single Action and Dual Action Pull Stations IDP-Pull-SA & lDP-Pull-DA The IDP-Pull-SA is a single action pull station requiring only one motion to activate the station. The IDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight lFP-series fire alarm control panels (FACPs). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation The lDP-Pull-SA and lDP-Pull-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double- gang or 4" (10.61 cm) square electrical box. You can also use the optional (Systcm Sensor® PN BC-TR) trim ring if the station is being semi-flush mounted. Compatibility The IDP-Pull-SA and lDP-Pull-DA are compatible with the following FACPs: IFP-2000 / RPS-2000 Intelligent Fire Panel lFP-2000ECS Emergency Communication System with Fire Panel lFP-1000 I ECS Intelligent Fire Panel Agency Listings MEA Up 67.02-E Vol ix For IDP.PuII.DA IDP-Pull-SA IDP.PuII-DA lFP-100 / ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350286 Rev G 0 2015 Honeywell International Inc CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0157 Page 1 of 1 CATEGORY: 7150— FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaachoneywelI.com DESIGN: Model IDP-PULL-SA manual pull box. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarn, pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 09-08-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Farenhyt SILENT KNIGHT by Honeywell IDP-Minimon I Agency Listings The IDP-Minimon is a compact and light weight addressable monitor module for use with Silent Knight lFP-series fire alarm control panels (FACPs). The IDP-Minimon acts as an interface to contact devices, such as waterfiow switches and pull stations. The IDP-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features Single contact monitor Small and lightweight size allows for flexible mounting options Support for Class B wiring Fully supervised Rotary address switches for fast installation Analog communications UL Listed Installation The IDP-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. ir IDP-Minimon Compatibility The IDP-Minimon is compatible with the following FACPs: IFP-2000 I RPS-2000 Intelligent Fire Panel lFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 / ECS Intelligent Fire Panel lFP-100 / ECS Intelligent Fire Panel TFP-50 Intelligent Fire Panel PIN 350279 Rev G Copyright© 2015 Honeywell International Inc CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module IDP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, IDP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2 SK-Monitor-2, dual monitor modules,and IDP- RELAYMON-2, *SKRELAYMON2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and lDP-Zone-6 the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit XLF: 7300-0028:0219 Rev. 10-25-11 mt 1' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division j 225-02-E Vol. V MEA IDP-Photo (Base not Included) Installation The lDP-Photo and lDP-Photo-T plug into a compatible lDP-series detector base. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detector. Compatibility The IDP-Photo, IDP-Photo-T and IDP-PhotoR are compatible with the following IDP-series detector bases: B21OLP 6" Mounting Base B501 4" Mounting Base B224Bl 6" Isolator Base B224RB 6" Relay Base B200SR 6" Sounder Base The IDP-Photo, IDP-Photo-T and IDP-PhotoR are compatible with the following FACPs: lFP-2000 I RPS-2000 Intelligent Fire Panel lFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 / ECS Intelligent Fire Panel IFP-100 I ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel Farenhyt SILENT KNIGHT -., by Honeywell Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal lDP-Photo, lDP-Photo-T and IDP-PhotoR The lDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight lFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. lDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors. It is UL 268A listed when used with the DNR (W) duct smoke detector. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the lDP-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3600 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System Sensor' PN RA1 OOZ) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed P/N 350280 Rev H Copyright © 2017 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of 1 CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SE01JR1TY7550 Meridian Circle, Maple Grove, MN 553694927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models lDP-PHOTO, IDPPHOTOR*, lDP-PHOTO-T, IDP-ACCLIMATE, SK-PHOTO, SKPIlOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model lDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is IQI approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models lDP-PHOTO and IDP-PNOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 Rev. 02-01-10 fm 1• This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division