2701 LOKER AVE W; 110; FPC2018-0409; Permit
4(C ity of PERMIT REPORT Carlsbad Print Date: 12/02/2020 Permit No: FPC2018-0409 Job Address: 2701 LOKER AVE W, # 100, CARLSBAD, CA 92010-6637 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090812200 Track 4*: Applied: 12/14/2018 Valuation: $185,528.39 Lot 4*: Issued: 01/03/2019 Occupancy Group: Project 4*: Finaled Close Out: 02/11/2019 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check #: Final Inspection: Project Title: Description: TRANSPORTATION MANAGEMENT & DESIGN INC - SPRINKLER MONITORING SYSTEM Applicant: FPContractor: COSCO FIRE PROTECTION INC COSCO FIRE PROTECTION INC JOHN MOCKER 1075W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Ftt 201 go" 0461 NisipM MAILAN Ie EDWARDS Catalog D Small Building Fire alarm Solutions LIFE SAFETY 5'INCIDENT MANAGEMENT Intelligent Fire Alarm Systems 0649 iOl 000 IL . IEI - cowAof4 FDNY COA 6227 * 7165-1657: 0244 Overview EDWARDS brand intelligent life safety systems offer the power of high-end intelligent processing in configurations that deliver uncomplicated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily- configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The 1064 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The 101000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses The iOl 000 panel includes four NACs that may be wired for either Class A or Class B operation. The RZ116-2 module adds even more capacity to iO installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them an ideal retrofit solution that can accommodate new intelligent detectors, as well as existing conventional devices. 0 Series supports a wide range of high-end features, including: Signature Series intelligent modules, detectors, and bases A-Series remote annunciators SIGA-REL Releasing Modules Fully integrated CO detection using Signature Series detec- tors with or without audible signaling Features Auto-programming speeds installation time Supports Signature Series intelligent modules and detectors Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Alarm ON command manually activates alarm condition Page 1 of 8 DATA SHEET E85001 -0135 Not to be used for installation purposes. Issue 1.3 Application EDWARDS 10 Senes life safety systems are powerful intelligent solu- tions for small to mid-sized buildings. Advanced intelligent technol- ogy delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Signature Series electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Mean- while, innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Addressable Technology boosts the reliability of EDWARDS fire alarm systems. When combined with i0 Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All EDWARDS systems are built to exacting reliability benchmarks. Clear-cut remote annunciation Remote annunciation is a strong suit of the i0 Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. i0 control panels also supports graphic annunciation with optional RA Graphic Annunciator interface mod- ules. Each interface provides common control and 32 LEDs. Flexibility built right in Two frilly-programmable front panel switch/LED combinations provide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Programming and remote diagnostics EDWARDS iO Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, i0 Series systems interface to a PC running com- patible 10-CU software. This option offers full system configuration in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of iO Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to download to the panel from the iO-CU, or upload and view system reports using the iO-CU. Available system reports include: Correlation groups, Device de- tails, Device maintenance, History, Internal status, System configu- ration, System status, Walk test, Dialer, and CO runtime. Perfect for retrofits EDWARDS 10 Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to 10 technology without the expense or disruption of rewiring the en- tire building. 10 control panels also support the ingenious RZ116-2 Zone Module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intelligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Scalable lP and Cellular Communications Several popular third-party IP/Cellular communicators have been tested with the i0 control panels and are compatibility listed to UL864. The IF/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/ Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the i0 control panel compat- ibility documentation part number 3102353-EN for a full list of compatible communicators. Signals with a difference i0 system NACs are configurable to fully support the advanced signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances. These devices offer precision synchro- nization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. A complete line of accessories 10 Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions (2) (3) (4) - D7 O T 1 0 0 0 0 0 0 ;134 09.1 Surface Mounting Holes (3) Backbox with Door Attached Semi-flush mounting Holes (4) Backbox with door and trim kit attached. Panel dimensions, in (cm) - Model 01* I 02 I 03 I I)4 __j_ 65* I D6 I 07 I 08 I 09 28.0 I 101000 3.85 I 9.0 I 22.0 I 15.75 10.25 I 4.4 I 28.2 2.7 1 (71.1) I psi I (22.8) (55.8) 140.01 (26.0) I (iii) I (71.6) (6.8) 064 21.5 I 3.85 I 7.5 I 15.5 14.25 10.25 4.5 I 21.7 2.7 1 (54.6) I (9.8) I (19.0) (39.4) 136.21 126.01 I (11.4) ).1) (6.8) *Add 1-1/2/n. (3.81 cm) toOl and 05 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. ID2'1 Page 2of8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Panel Layout 4 13 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (Ji) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (,J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries System Layout 101000 Any combination of two single- or dual-Signature-loop. modules V f Standard Loop 250 points-a-t-* (one expansion slot) 10 SDC2 Expander, Loop 1 of 2 250 points Up to 125 sensors and 125 modules per loop 'j 10-SDC1 Expander Loop: 250 points (one expansion slot) I Up to 20,000 feet of wiring per loop (one expansion slot) i0-SDC2 Expander, Loop 2 of 2: 250 points I----------------------------------------------------------------- - Four Class B or two optional Class A NACs e Optional 10 A or 6.5 A Booster Ethernet (SA-ETH) DACT/er(SA-DACT) RS-232 (SA-232) Relays. Two Form C, one Form A e Each iOl 000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. 101000 loops support 125 detectors and 125 modules. i064 1i Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring. 0:7 § j UJH Two Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Power Supply Up to eight remote a~nunclators I Ethernet (SA-ETH) DACT/DIerDAC RS-232 (SA-232) Relays. Two Form C, one Form A Each i064 panel ships with one Signature loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. Page 3 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Cloco A wiring Wiring & Configuration Signature device loop The system provides one Signature device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit 01000 1064 specifications Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20 V peak-to-peak linevoltage Circuit current 0.5 A max Circuit 660 total, 0.5 pF, max impedance - Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using a SIGA-CC1 S or SIGA-MCC1 S module and Genesis or Enhanced Integrity notification ap- _________________ pliances. Class A wiring L,pc,d deco do Loop cord octo Line Za Notification appliance circuits (TB2) 01000 control panels come equipped with four notification ap- pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications - 101000 1064 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage 24 VF\NR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 26.0 total, 0.35 IJF max EOLR - 15K0,1/2 W Synchronization Supported system-wide -- Class 8 wiring Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two (1) wire smoke detectors. Aux 2 can be software selected to operate continuously. The circuit is supervised for shorts and grounds. (2) Circuit specifications Circuit voltage 21.9 to 28.3 V range Resettable circuit 24 VDC nominal at 500 mA (3) (Aux power 2) Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two-wire smoke detectors. (4) Note: Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that amount. (1) Trouble Alarm, trouble, and supervisory relay (TB3) (2) Supervisory The trouble relay is normally-open, held closed, (3) Alarm and opens on any trouble event or when the panel is de-energized. The supervisory relay is (4) Smoke/Aux normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Alarm I Trouble Supervisory Type Form C I Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style Y) or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Class B Class A Channel 1 channel 2 channel 1 channel 2 T84 Annunciator Annunciator )cH1 (+) IN CH1 IN cHi (-) IN 012 (+) IN cH2 (+) IN cH2 (-) IN cH2 (-) IN Page 4 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Option Cards EDWARDS iO Series panels are supported by a complete line of modules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet provides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with the i064 as a replacement for the standard 64-point loop, or with the iO1000 as a 250-point expansion module. The iO-SDC2 is a 500-point dual loop controller card for the 01000 that provides two SLC circuits, each with 125 detector addresses and 125 module addresses. Specifications iO-SDC1 iO-SDC2 Device Addresses iOl000: one loop, 250 device addresses 1064: 64 addresses 101000: two loops, 500 device addresses Wiring Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Alarm: 80 mA Standby: 45 mA Alarm: 70 mA Note.' These ratings do not include the use of two-wire smoke modules. Communication Line Max. 20.6 V peak-to-peak Voltage Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current 0.5 A max. Max total loop 66 0 resistance Max total loop 0.5 pF capacitance Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0 to 5 kO Impedance Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card SA-ETH wiring To network The SA-ETH card provides a standard 10/100 Base T Ether- Network cable Network cable-1 connection net network connection for connecting to an intranét, a local network, or the Internet. The TItIIII!ltIIT3flO f card can be used to download lr n configuration programming from the 0-CU to the panel. The Ethernet card is installed on the plastic assembly and con- nects to the main circuit board Ethernet card via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Page 5 of 8 RZ116-2 Remote Zone Interlace Module The RZI16-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZ116-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZI16-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA! circuit Standby current for 3.9 k EOL (Canada) 5.7 mA/ circuit Alarm current at nominal voltage 31.1 mAt circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kO (U.S.); 3.9 kO Canada Zone voltage 22.78 V for 4.7 kO (U.S.) 22.08 V for 3.9 kO (Canada) Alarm current 31.1 mA' channel at nominal voltage Alarm impedance range <680 0 Trouble impedance range > 5.55 kO Supervised output circuits EOL resistor 15 IcC) Quantity 2 Short circuit detection <2.6 IcC) Open circuit detection > 61.9 IcC) Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), iO1 000, APS DATA SHEET E85001 -0135 Not to be used for installation purposes. Issue 1.3 SA-DACT wiring 1,. re jack Phone (su The dialer phone lines connect to connectors on the dialer's main circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector 1. (3) (4) (5) LED 1 LED 2 LED Expander 1 LED Expander 2 Alarm/non-alarm and trouble zone LEDs SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the iO-CU. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-DACT specifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31/38X) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBII CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch 06600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID SA-232 RS-232 interface SA-232 wiring The SA-232 card provides an RS-232 in- terface with iO panels. It can be used for GND(blackwire) r- TXD (white wire) connecting a printer to the control panel r RXD (red wire) to print system events. The card also can be used for connecting a computer to download a configuration program from the iO-CU to the control panel. 00, The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard EIA-232 Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (i064 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with 1064 control panels only. iO1 000 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VFWR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 to-18 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) D1 61-40 LED Display Expander (iOl 000 only) The D16L-iO LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone. Two D16L-iO LED display expanders can be installed in each iO1000 panel. Page 6 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Specifications 'i064 i01000 - Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (1 25 modules) detectors and 125 modules max.). Addresses 1 to 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B (Style 't, Class A (Style Z) optional 4 Class B (Style V) or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC circuit Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21.9 VDC, special application Note: Fora list of compatible devices, see the i064 and iO1000 Series Compatibility List (P/N 3102353-EN) Loop circuit Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 liE Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/115 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the i064 control panel cabinet and two 18 Ah batteries will fit in the iOl 000 control panel cabinet. If larger batteries are required, use an EDWARDS battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38X) Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 kO Alarm contact Form C N.O. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.C. 24 VDC at 1 A (resistive load) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm9 Page 7of8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 Ordering Information Part Description - 01000 Fire Alarm Systems 1010003 Four loop system with one 250-point loop installed. llov, gray door. LIFE SAFETY & INCIDENT MANAGEMENT 1010003-2 Four loop system with one 250-point loop installed. 230v, gray door. 1010003-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. Contact us... 101000G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. Email: edwards.fire@fs.utc.com 1010003-CA Four loop system, one 250-point loop installed. 110v, gray door, LED strips, Canada. Web: Edwards-fire.com 101000GD Four loop system, one 250-point loop installed. llov, gray door, with dialer. 1010003-F Four loop system, one 250-point loop. llov, gray door, LED strips, French Canada. 1010003-PG Four loop system with one 250-point loop installed. llov, gray door, Portuguese. EDWARDS is UTC brand 101000G-SP Four loop system with one 250-point loop installed. 110v, gray door, Spanish. 1016 Corporate Park Drive Mebane, NC 27302 101000R Four loop system with one 250-point loop installed. llov, red door. I01000R-2 Four loop system with one 250-point loop intalled. 230v, red door. © 2017 United Technologies Corporation. I01000RD Four loop system, one 250-point loop installed. 110v, red door, with dialer. All rights reserved. SA-TRIM2 i01000 Flush mount trim, black. 1064 Fire Alarm Systems 10643 One loop system with one 64-point loop installed. llov, gray door. 10643-2 One loop system with one 64-point loop installed. 230v, gray door. 10643-2-PG One 1000 system with one 64-ooint looD installed. 230v. arav door. Portuauese. I064GD One loop system, one 64-point loop installed. llov, gray door, with dialer. I064GL One loop system, one 64-point loop installed. 110v, gray door, English Canada. I064GL-F One loop system, one 64-point loop installed. llov, gray door, French Canada. 10643-PG One loop system with one 64-point loop installed. 110v, gray door, Portuguese. 10643-SF One loop system with one 64-point loop installed. 110v, gray door, Spanish. I064R One loop system with one 64-point loop installed. 110v, red door. I064R-2 One loop system with one 64-point loop installed. 230v, red door. I064RD One loop system, one 64-point loop installed. llov, red door, with dialer. SA-TRIM1 i064 Flush mount trim, black Option Cards iO-SDC1 Expansion module, one 250-device loop. 10-SDC2 Expansion module, two 250-device loops, 500 devices total. For i01000 only. RZI1 6-2 Remote Zone Interface Module. 16 Class B IDCs, 2 Class B Output. Includes bracket. SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. iO64 systems only. D1 6L-i0-2 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. For i0i000 only. __ D16L-i0-1 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. For iOl000 only. D8RY-i0-2 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iO1000 only. D8RY-10-1 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For 01000 on/. Accessories CTM City Tie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8' x 14" x 3.5" - red. SIGA-REL Releasing Module PT-1S System Printer BC-1 Battery Cabinet. 14.0° x 18.25" x 7.25". Holds two 12V24A batteries. BC-1 R Battery Cabinet - Red. 14.0" x 18.25' x 7.25". Holds two 12V24A baftees. BC-1 EQ Seismic hardening Kit for lO series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools - iO-CU 10 Series configuration and diagnostics utility. 260097 RS232 cable. 4 conductor. DBQ PC interface Page 8 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0244 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterflow and sprinkler supervisory service. Models "EST" i01000G, iO1000G-2, iO1000GD, i01000R, iO1000R-2, i01000RD, i064G, i064-GD, i064-R, i064-RD, i064G-2, i064R-2; i0500G, i0500GD, i0500R, i0500RD, i0500G-2, i0500R-2. Models "Vigilant/Kidde" VSI-G, VS1-GD, VS1-R, VS1-RD, VS1-G-2, VS1-R-2; VS2-G, V52-GD, V52-R, V52-RD, V52-G-2, V52-R-2, vs4-G, v54-G-2, vs4-GD, vs4-R, v54-r-2, vs4-RD,. Models "FireworX/Kidde" FX-64G, FX-64GD, FX-64R, FX-64RD, FX64G-2, FX-64R-2, FX-254G, FX-254GD, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1000, FXI000D. Models 'Edwards Signaling" E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA250RD System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; R5232 Module D16L-iO, -VS, -Fa, D8RY-iO-1, D8RY-iO-2, D8RY-VS, 16 Zone Front Panel LED XAL250, V-SLC, XAL127; SLC Loop Driver io-SDC1, V-SLC2-1, FX-SLCI Single SLC Card, 250pt io-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *500pt *pT1..S: System Printer *PT1..p: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible nitiating and indicating devices. *These control units meet the requirement of UL 864, 9th Edition Standard. *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 4:1P1l-U]1Sles LIFE SAFETY INCIDENT MANAGEMENT EDWARDS® Catalog Intelligent Initiating Devices Intelligent Smoke Detector SIGA-PD Overview The Signature Series SIGA-PD optical smoke detector brings advanced sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life safety and property protection capabilities. Continuous self-diagnostics ensure reliability over the long-haul, while environmental compensation helps reduce maintenance costs. Like all Signature Series detectors, the SIGA-PD is an intelligent device that gathers analog information from its optical sensor, converting this data into digital signals. To make an alarm decision, the detector's on-board microprocessor measures and analyzes sensor readings and compares this information to historical data. Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. S853 * Standard Features Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Next Generation Optical Smoke Sensing Technology Wide 0.53 to 3.94 %/ft. (1.7 to 12.35 %/m) smoke obscuration Uses Existing Wiring Automatic Device Mapping Up To 250 Total Signature Addresses Per Loop Two Levels of Environmental Compensation Two Levels of Dirty Detector Warning Twenty Pre-Alarm Settings Five Sensitivity Settings Non-Volatile Memory Electronic Addressing Identification of Dirty or Defective Detectors Automatic Day/Night Sensitivity Adjustment Bicolor (Green/Red) Status Led Standard, Relay, Fault Isolator, and Audible Mounting Bases Sensor Markings Provide Easy Testing Identification Page 1 of 4 DATA SHEET E85001 -0646 Not to be used for installation purposes. Issue 1.2 Application The SIGA-PD detects extremely small particles of combustion and triggers an alarm at the first sign of smoke. Thanks to its high-performance forward-scattering reflective response technology, the photoelectric smoke sensor responds quickly and reliably to a wide range of fire types, especially slow burning fires fuelled by combustibles typically found in modern multi-use buildings. Compatibility The SIGA-PD detector is compatible only with the Signature Loop Controller. Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square - Self-locking tab electrical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing LED Indicator centers. See mounting base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series detector constantly runs self-checks to provide important maintenance information. The results of the self-check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each devices installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitivity measurement can also be transmitted to the loop controller. A sensitivity report may be printed to satisfy NFPA sensitivity measurements, which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Accessories Detector mounting bases have wiring terminals that are accessible from the "room-side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SIGA-1134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4 inch square box only. SIGA-AB4G/T/LF SIGA-SB SIGA-IB SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED SIGA-LED - The remote LED connects to the SlGA-SB or SIGA-5B4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - Signature Series sounder bases are designed for use where localized or group alarm signaling is required. SIGA-AB4G bases provide sounder capability to Signature Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire-plus-CO mode. SIGA-AB4GT bases provide sounder capability to Signature Series smoke and heat detectors, as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator. SIGA-AB4G-LF bases provide 520 Hz low frequency sounder capability to Signature Series smoke and heat detectors, as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator. The SIGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Page 20f4 DATA SHEET E85001 -0646 Not to be used for installation purposes. Issue 1.2 Standard Detector Base, SIGA-SB, SIGA-SB4 SIGA-AB4GT, SIGA-AB4G, SIGA-AB4G-LF: 1 Volume Setting Default = Nigh Max resistance Cut/remove — per wire jumper for must not exceed low dB - 10 Ohms - 24Vdcin - DATA OUT 1+1 From power supply To Next Device or previous base + Data in From Signature Controller or previous device + 0 0 \ SIGA-AB4G-LF: Jumper cuts Output Mode Default = Fire Cut/remove jumper for Fire plus CO SIGA-AB4G: Tone Setting M1 MT1 DA— Default = Temporal 00. 550- mrs IN INIOW Cut/remove jumper for Steady ____________ SIGA-AB4GT: Not Used - 24Vdc out + To nest base or EOL relay Data out to nest Signature device 4. This is the basic mounting base for EDWARDS Signature Remote LED Series detectors. The SIGA- LED Remote LED is supported i1. by this Base. I Term Description 1 Not Used I I 2 DATA IN/OUT () I I 3 Not Used I 4 DATA IN (-) I DATA IN J-) Z 4 Remote LED (-) 5 Remote LED )) 6 Not Used I DATA INI+l 7 DATA OUT C-) From Signature Controller or Previous Device Isolator Detector Base, SIGA-113, SIGA-I134 Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes. Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. Audible Sounder Bases, Fire Mode AB4G] AB4G, AB4G-LF sounder bases This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. Warnings & Cautions The isolator operates as follows: - a short on the line causes all isolators to open within 23 IT - at 10 msec intervals, beginni on one side of the Class A circuit nearest the loop controller, the isolators DA1 close to provide the next isolator down DATA IN (+) the line with power From Signature Controller or Previous Device - when the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Relay Detector Base, SIGA-RB, SIGA-RB4 This detector does not operate without electrical power. As fires frequently cause power interruption, discuss further safeguards with the local fire protection specialist. This detector does not sense fires in areas where smoke cannot reach the detector. Smoke from fires in walls, OUT roofs, or on the opposite side of closed doors may not reach the detector. DATA OUT (+) To Nest Device Term Description 1 Not Used 2 DATA IN/OUT )~) 3 DATA IN)-) 4 Not Used 5 Not Used 6 DATA OUT)-) 7 Not Used Photoelectric detectors have a wide range of fire-sensing capabilities and ares best suited for detecting slow, smoldering fires. In Canada, install according to CAN/ULC-5524 Standard for the Installation of Fire Alarm Systems, CSA C22.1 Canadian Electrical Code, and the local authority having jurisdiction. This base includes a relay. Normally Open or Normally Closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel. The relay base does not support the SIGA-LED Remote LED. Normally- NormoMy- JZ DATA IN (,) DATA OUT lv> From slgr,arase Controller To Next Device or Previous Device Term Description 1 Normally Open CONTACT RATING 2 DATA IN/OUT (+) 1.0Mip6l30VDC 3 Common (Pilot Duty) 4 5 6 7 DATA IN )-( Not Used Normalt/-Closed DATA OUT (-) DAT Page 3 of 4 DATA SHEET E85001 -0646 Not to be used for installation purposes. Issue 1.2 Dimensions LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: edwards-fire.com 00 1016 Corporate Park Drive Mebane, NC 27302 EDWARDS is a registered mark in the United States and other countries. © 2018 United Technologies Corporation. All rights reserved. Specifications 04,299 OR fl Operating voltage 15.20 to 19.95 VDC Normal operating current 51 pA Alarm current 68 pA Smoke Sensitivity Range ULJULC: 0.53 to 3.94 %Ift. (1.7 to 12.35 %/m) obscuration Vibration level 10 to 35 Hz, with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft/mm (0 to 20 m/s) Wall mounting 12 in. (305 mm) max. from ceiling Compatible bases See Ordering Information Compatible detector testers Testifire 1000, Testif ire 2000 Operating environment 32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing Construction High Impact Engineering Polymer, White Storage temperature -4 to 140°F (-20 to 60°C) Environmental compensation Automatic Agency Listings CAN/ULC-S529, UL 268, 268A. CSFM, FM approved Ordering Information Catalog Ship Wt. Description Number lbs (kg) SIGA-PD Intelligent Optical Smoke Detector 0.4 (0.16) Accessories SIGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base clw Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2 (.09) Page 4 of 4 SIGA-113 Detector Mounting Base w/Fault Isolator SIGA-I134 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt SIGA-LED Remote Alarm LED (not for EN54 applications) SIGA-AB4G Audible (Sounder) Base for Fire Detectors 0.3 (0.15) SIGA-AB4G-LF Low Frequency Audible (Sounder) Base for CO and Fire Detectors 0.3 (0.15) SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors 0.3(0.15) SIGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04) SIGA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04) SlGA-DMP Detector Mounting Plate 3.0 (1.4) SIGA-VA Detector Cleaning Tool DATA SHEET E85001 -0646 Not to be used for installation purposes. Issue 1.2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM b LISTING SERVICE LISTING No. 7272-1657:0331 Page 1 of 2 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-PD, *SIGI..PD *KIPD and *KIR..pD Analog addressable photoelectric smoke detectors. *Model SIG[-PD is similar to Model SIGA-PD except for isolation circuitry. *Model KI-PD is identical to Model SIGA-PD except for trade name. *Model KlR-PD is similar to Model SIGA-PD except for control panel compatibility. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 15.2-19.95 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72 and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. *Models SIGA-PD and SIGI-PD are under the Edwards brand. *Models KI-PD and KIR-PD are under the Kidde brand. APPROVAL: Listed as analog addressable photoelectric smoke detectors. *Model KI-PD is for use with listee's Models VS1, V52 and V54 (CSFM No. 7165-1657:0244); VM-1 (CSFM No. 7165-1657:0309) fire alarm control units. *Models SlGA-PD and SlGl-PD are for use with listee's Models EST3 (CSFM No. 7165-1657:0186); i064, i0500 and iO1000 (CSFM No. 7165-1657:0244); EST3X (CSFM No. 7165-1657:0306) fire alarm control units. *Model KIR-PD is for use with listee's Models FX-64, FX-254 and FX-1000 (CSFM No. 7165-1657:0244) fire alarm control units. *Model SIGA-PD is for use with listee's bases: Models SIGA-S13, -SB4, -RB, -RB4, -IB, -1B4 (CSFM No. 7300-1657:0120); SIGA-AB4G (CSFM No. 7300-1657:0222); SlGA-AB4GT (CSFM No. 7300-1657:0307) and SIGA-AB4G-LF (CSFM No. 7300-1657:0322). *Model SIGI-PD is for use with listee's bases; Models SIGI-AB4G (CSFM No. 7300-1657:0222); SlGI-AB4GT (CSFM No. 7300-1657:0307) and SIGI-AB4G-LF (CSFM No. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7272-1657:0331 Page 2 of 2 7300-1657:0322). *Models KI-PD and KIR-PD are for use with listee's bases; Models KI-ABST (CSFM No. 7300-1657:0222), KI-ABDT (CSFM No. 7300-1657:0307) and KI-ABLT (CSFM No. 7300-1657:0322). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-15-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Input Modules SIGA-CT1, SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 EDWARDS Catalog II> Intelligent Input-Output LIFE SAFETY INCIDENT MANOEMENT SIGA-MCT2 MEA 73057 S3424 0121 Overview The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tem- perature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CT1, SIGA-CT1 HT and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-CT1 HT module operates at an expanded temperature range of 32 OF to 158 OF (0 °C to 70°C) for those applications requiring more extreme environmental temperature variation. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UlO modules. Two- and six-module UIO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Standard Features Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. SIGA-CT1 HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from EDWARDS Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. Automatic Device Mapping -The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or as-built" drawing information showing branch wiring (1-taps), device types and their address are stored on disk for printing hard copy. Installation SIGA-CTI, SIGA-CT1 HT and SIGA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Wall plate, white (1-gang) 4, IIII:J \ is LEDs LED viewing ports SIGA-MCT2: mount the UIO motherboard inside a suitable ED- WARDS enclosure with screws and washers provided. Plug the SIGA-MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Page 2 of 4 UIO Motherboard 6-32 self-tapping screws Eff o;H: #6 Flat washers Lj -Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two per- sonality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterfiow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 DATA IN (+)> ( \ I DATA OUT (+) 1 DATA IN (-)> DATA OUT (-) From Signature Controller T To Next Device or Previous Device SIGA-CT2 I I TY6°1 NO E,12i06fl9 I I + Jl + + + + UL/ULC hoSed I .1. I I .1. I I I input 2 InPut' 471522201 ll l DotoIn Signature S D000 2 Orcuit + D- Out Cr52,, LED iNOnrroil Red LED hoosvel INo connections Or j en per reoingo rRqdred 50, MCRD. SIGA-MCT2 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance ] 0.1pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) 4,000 ft (1,219 m) #14 AWG (1.50 mm2) #12 AWG (1.50 mm2) Typical N.C. Initiating Device Typical N.C. Initiating Device INPUT 1 INPUT 2 A AA Style B (Class B) TB2 I I I TB2 Ifl UL/ULC Listed 471(0 EOL UL/ULC Listed Style B (Class B) ) 8 7 6 5 ii (Alarm/Acte) © 471(83 EOL /\ L 4\ I ULIULC Listed 471(8) EOL Red LED ________ Green LED (Normal) Red LED © 0 4 ________________ Green LED 321 (Alarm/Active) 4 3 2 1 (Normal) I ________ TB1 IKI OD ®:JDiI Fha GOaDI f DATA IN(+)> m. DATA OUT (+) 1 DATA IN(-) > DATA OUT (-) From Signature Controller Y To Next Device or Previous Device A SIGA-CT1, SIGA-CT1 HT NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm2 (wire: Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. Maximum 10Vdc@350iiA The SIGA-uI06R and the SIGA-U102R do not come with T131 4. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. Page 3 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: Edwards-fire.com EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications Catalog Number SIGA-CT1HT I SIGA-CT1 SIGA-CT2 I SIGA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types 49 (factory set) Four sub-types (personality codes) are available (personality codes) are available Uses One Module Address Uses Two Module Addresses Address Requirements Operating Current Standby = 250pA; Activated = 400iJA Standby = 396pA; Activated = 680pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one-gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and SIGA-MP mounting plates U102R16R/6 Motherboard Operating Environment 32°F to 120°F (0°C to 49°C) Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM Ordering Information Catalog . - - Ship Wt. Description Number lbs (kg) SIGA-CT1 Single Input Module - UL/ULC Listed 0.4 (0.15) SIGA-CT1 HT Single Input Module High Temperature Operation ULJULC Listed 0.4 (0.15) SIGA-CT2 Dual Input Module - ULJULC Listed 0.4(0.15) SIGA-MCT2 Dual Input Plug-in (UIO) Module - UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0 (0.6) 27193-13 Surface Mount Box - White, 1-gang 1.0 (0.6) SIGA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32 (0.15) - Two Module Positions SIGA-U106R Universal Input-Output Module Board w/Riser Inputs 0.62 (0.28) - Six Module Positions SIGA-Ul06 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module 7.0 (3.1) Mounting Plates SIGA-MB4 Transponder Mounting Bracket (allows for mounting 0.4 (0.15) two 1-gang modules in a 2-gang box) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint -- 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4o14 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1657:0121 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models SIGA-CC1, SIGA-CC2, SIGA-CTI, SIGA-CTIHT, SIGA-CT2, SIGA-CR, SIGA-CRR, SIGA-UM, SIGA-MM1, SIGA-WTM, SIGA-IM, SIGA-MDM, SIGA-MAB, SIGA-MCT2, SIGA-MCC1, SIGA-MCC2, SIGA-MCR and SIGA-MCRR remote transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SIGA-MP1, SIGA-MP2 and SlGA-MP2L mounting plates. Models SIGA-U102R, SIGA-U106 and SIGA-U106R motherboards. Model CS-SIGA-CCIP releasing module. Models SIGA-CC1S and SIGA-MCCIS Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. Model SIGA-CTIHT; Signature Series High Temperature Single Input Module. *SIGACRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2- 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:121 and 7300-1388:178 *Rev 01-11-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TG=7FS LTE-A P/N:TG7LAF01 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD t COMMERCIAL FIRE PRODUCT FEATURES . Certified for use on the AT&T LIE network for long, sunset- free installation. I- Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms by providing dual paths for self-tests. 1- Falls back to 3G/4G if an LIE network is not available, for extended network coverage. The Telguard TG-7FS LIE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LTE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-A because of the new sixty minute supervision mode. The TG-7FS LIE-A can also be installed as a backup path and upgraded to sole path at a later date. iii; 1lI!tb! f!Ji 4J1T?11 i1.]-1ll ¶y 'iqtt Ij TI o I! Tb YI 4 LPZGtJ4 !Jj 4!1u1tJJ • ULC Listings S545 • Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.lelguard.com. TELGUARD TG=7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. UL Listings Commercial Fire 864 Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems Telguard, a Division of Tetular Corporation 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA 800-229-2326, Option 5 www.Telguard.com • Copyright ©2017 Telular Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7LAA02, *TG7LA001 *TG7LAA01 TG7LA002, *TG7LAF0I TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7LAF01 TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DAd. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. FPC20I8-0409 2701 LOKER AVE W #100 TRANSPORTATION MANAGEMENT & DESIGN INC - SPRINKLER MONITORING SYSTEM 2090812200 12/14/2018 F P C 201 '8-0409 * Revised 10-03-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should nct be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, instalation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division