Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2701 LOKER AVE W; 120; AS150364; Permit
City of Carlsbad Sprinkler Permit Permit No: AS150364 2701 LOKER AV Job Address: WEST Permit Type: SPRINK Parcel No: 2090812200 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 12/17/2015 Approved: 1/4/2016 Issued: 1/4/2016 Inspector: Project Title: PALOMAR CREST SPEC STE 120 Applicant: WESTERN FIRE PROTECTION 13630 DANIELSON ST P0 WAY CA 92064 858-513-4949 Owner: GATEWAY COLORADO PROPERTIES INC C/O TTAIE PROPERTY TAX - DEPT 207 P 0 BOX 4900 SCOTTSDALE AZ Fees ($) Add'I Fees ($) Total ($) Balance ($) 303 0 303 0 A5150364 tq cci Fire Pro tectio, A5 150365 Norldwide Contacts Products www.tyco-fire.com Series EC-8 - ,-tactor ii r Extended Coverage (Light Hazard) L L Pendent and Recessed Pendent Sprinklers General Description The Series EC-8 Extended Cover- age Pendent Sprinklers are decora- tive glass bulb sprinklers designed for use in light hazard occupancies. They are intended for use in automatic sprinkler systems designed in accor- dance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 400 ft2 (37,2 m2), as com- pared to the maximum coverage area of 225 ft2 (20,6 m2) for standard cov- erage sprinklers used in light hazard occupancies. The recessed version of the EC-8, in- tended for use in areas with a finished ceiling, uses either the two-piece Style 30 or 40 Recessed Escutcheon. The Style 30 Recessed Escutcheon provides up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position, whereas, the Style 40 provides 3/4 inch (19,1 mm) of verti- cal adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheons reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the ap- plicable approval agencies, the test- ing is not representative of all possible IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 corrosive atmospheres. Consequent- ly, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive envi- ronment. The effects of ambient tem- perature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. The Series EC-8 Extended Coverage Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any oth- er authorities having jurisdiction. Fail- ure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) 1Y4232 - Pendent, 8.0K TY4232 is a re-designation for C4232 Technical Data Approvals UL and C-UL Listed. FM Approved NYC Approved. (Refer to Table A for complete approv- al information including corrosion re- sistant status. The Approvals apply to the service conditions indicated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) DECEMBER 2014 Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K=8.0 gpm/ps1112 (115,2 1pm/bar1'2) Temperature Ratings 135°F (57°C) and 155°F (68°C) Finish Sprinkler: Refer to Table A Recessed Escutcheon: Natural Brass, Signal White, Chrome Plated Physical Characteristics Frame ............................Bronze Button............................Bronze Sealing Assembly ...........Beryllium Nickel w/TEFLON Bulb .....................Glass (3 mm dia.) Compression Screw ................Bronze Deflector...........................Brass TFP223 FF_FP223 Page 2 of 6 Components: 3/4" ESCUTCHEON PLATE 1 - Frame 2 - Button 3 - Sealing Assembly 4 - Bulb *Temperatureratlng ls (12,7 mm) M SEATING SURFACE J 2-1/8' 5 - Compression Screw (54,0 mm) 6 - Deflector * NOMINAL 16 indicated on Deflector. MAKE-IN (36,5 mm) ** Pipe thread connections per ISO 7-1 can be provided 6 on special request. FIGURE 1 SERIES EC-8 (TY4232) EXTENDED COVERAGE PENDENT SPRINKLER SPRINKLER FINISH (See Note 4) HAZARD TYPE TEMP. BULB LIQUID NATURAL I CHROME I POLYESTER* BRASS PLATED Light Pendent 135°F (57°C) Orange 1, 2, 3, 5 155-F (68-C) Red Refer to Table B for UL and C-UL Rec. Pendent 135°F (57°C) Orange Sensitivity Rating and wl Style 30 Esc. 1, 2,3, 5 155°F (68°C) Red Refer to Table C for FM Sensitivity Rating Rec. Pendent 135°F (57°C) Orange w/Style 40 Esc. 1,2,5 155°F (68°C) Red NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Approved by the City of New York under MEA 113-04-E. *Frame and Deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Operation The glass bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The Series EC-8 Extended Cover- age Pendent Sprinklers must only be installed in accordance with the ap- plicable UL and C-UL Listing or FM Approval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C). UL and C-UL Listing Requirements The Series EC-8 Sprinklers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all of the sprin- klers in the design area. With respect to heat sensitivity, the Series EC-8 Sprinklers can be used with unobstructed construction consisting of flat, smooth ceilings (including bar joists) with a maxi- mum pitch of one in six as defined and permitted by NFPA 13. The minimum allowable spacing between the Series EC-8 Sprin- klers, to prevent cold soldering, is 8 ft. (2,4 m). The Series EC-8 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for extended coverage pendent sprinklers. FM Approval Requirements The Series EC-8 Extended Coverage Sprinklers are to be installed in ac- cordance with the applicable Factory Mutual Loss Prevention Data Sheet. Information provided in the FM Loss Prevention Data Sheet relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spac- ing, and deflector-to-ceiling distance. TFP223 Page 3 of 6 Area Style 135°F (57°C) 155°F (68°C) 16x16 Pendant OR OR 16 x 16 Style 30 Recessed OR OR 16 x 16 Style 40 Recessed OR OR 18x18 Pendent OR OR 18 x 18 Style 30 Recessed OR SR 18 x 18 Style 40 Recessed OR SR 20x20 Pendent OR SR 20 x 20 Style 30 Recessed OR SR 20 x 20 Style 40 Recessed SR SR OR: Quick Response SR: Standard Response TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS Area Style 135°F (57°C) 155°F (68°C) 16x16 Pendant OR OR 16 x 16 Style 30 Recessed OR N/A 16 x 16 Style 40 Recessed N/A N/A 18x18 Pendent OR OR 18 x 18 Style 30 Recessed OR N/A 18 x 18 Style 40 Recessed N/A N/A 20 x 20 Pendent OR OR 20 x 20 Style 30 Recessed OR N/A 20 x 20 Style 40 Recessed N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-8 SPRINKLERS I Description Area I GPM I PSI I TY4232(K=8.0) Pendant I 16x16 I 26 I 10.6 I 18x18 I I33 17.0 I I 20x20 40 25.0 1 ft = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpm/ft2 = 40.74 mm/mm TABLE D FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS Installation The Series EC-8 Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.-Ibs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment of an escutch- eon plate by under-or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be in- stalled with the deflector parallel to the mounting surface. Pendent sprin- klers must be installed in the pendent position. Step 2. After installing the Style 30 or 40 mounting plate (or other escutch- eon, as applicable) over the sprinkler pipe threads, and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten pendent sprin- klers using only the W-Type 3 (End A) Sprinkler Wrench. Wrench tighten the recessed pendent sprinklers using only the W-Type 23 Sprinkler Wrench. The wrench recess of the applicable sprinkler wrench (Ref. Figures 4 and 5) is to be applied to the sprinkler wrench flats (Ref. Figure 1). TFP223 Page 4 of 6 FIGURE 2 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8 DIA. - 7/16±1/8 (73,0 mm) 1/2 (12,7 mm) (11,1±3,2 mm) 2-1/4 DIA. 1/4' (6,4 mm) FACE OF (57,2 mm) 1/8" SPRINKLER FITTING (3,2 mm) MOUNTING MOUNTING SURFACE PLATE CLOSURE 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) 2-7/8" DIA. 9/16±1/4" (73,0 mm) 3/4" (19,1 mm) (14,3±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) I __ SPRINKLER 1/8" FITTING _______ (3,2 mm) "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS - / (END "A") FIGURE 4 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS - fti_r ° FIGURE 5 W-TYPE 23 RECESSED SPRINKLER WRENCH MOUNTING SURFACE CLOSURE Care and Maintenance The Series EC-8 Sprinklers must be maintained and serviced in accor- dance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper au- thorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- MOUNTING PLATE = 1-5/16" (33,3 mm) 13/16" (20,6 mm) wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereaf- ter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive condi- tions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association (e.g., NFPA 25), in addition to the standards of any oth- er authorities having jurisdiction. The installing contractor or sprinkler man- ufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified In- spection Service in accordance with local requirements and/or national codes. FIGURE 3 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON TFP223 Page 5 of 6 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series EC-8 (TY4232), K=8.0, Extended Coverage (Light Hazard) Pendent Sprinkler, (specify) tem- perature rating, (specify) finish, P/N (specify): 135°F (57°C) Natural Brass .............PSN 50-801-1-135 Signal White (RAL9003) Polyester ................PSN 50-801-4-135 Chrome Plated ............PSN 50-801-9-135 155°F (68°C) Natural Brass .............PSN 50-801-1-155 Signal White (RAL9003) Polyester ................PSN 50-801-4-155 Chrome Plated ............PSN 50-801-9-155 Recessed Escutcheon Specify: Style (30 or 40) Recessed Es- cutcheon with (specify*) finish, P/N (specify*) *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify: W-Type 23 Recessed Sprin- kler Wrench, P/N 56-000-6-838 TFP223 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation Fire Protection Products