HomeMy WebLinkAbout2714 LOKER AVE W; 300; AS160174; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160174 2714 LOKER AV Job Address: WEST Permit Type: SPRINK Parcel No: 2090813200 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 5/27/2016 Approved: 6/8/2016 Issued: 6/8/2016 Inspector: Project Title: 2714 LOKER THIRD FLOOR STE. 300: ADD (22) PENDANT & (10) UPRIGHT SPRINKLERS TO ACCOMMODATE NEW TI IN EXISTING SPRINKLERED BLDG. Applicant: AMERICAN AUTOMATIC FIRE SUPPRESSION SUITE B 9510 PATHWAY STREET SANTEE CA 619-562-3010 Owner: CBLLLC 6183 PASEO DEL NORTE #280 CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 303 0 303 0 tqca Fire Protection Products Worldwide Contacts www.tyco-fure.com Series TY-FRL - 2,8.w 5,6,, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRL, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response, standard cover- age, solder type spray sprinklers de- signed for use in light and ordinary hazard commercial occupancies such as banks, hotels, shopping malls, schools, hospitals, etc. The recessed version of the 2.8 and 5.6 K-factor, Series TY-FRL Pendent Sprinkler, where applicable, is intend- ed for use in areas with a finished ceil- ing. It uses a two-piece Style 20 (1/2 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total ad- justment from the flush pen dent position. The adjustment provid- ed by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. An intermediate level version of the 5.6 and 8.0 K-factor, Series TY-FRL Pendent Sprinkler can be obtained by utilizing the Series TY-FRL Pen- dent Sprinkler in combination with the Model S4 Shield. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 IAL.)t(g The Series TY-FRL Sprinklers de- scribed herein must be installed and maintained In compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or sprinkler manufacturer with any questions. Sprinkler Identification Numbers TY1121 ...... Upright 2.8K, 1/2"NPT TY1221 .... Pendent 2.8K, 1/2"NPT TY3121 .....Upright 5.6K, 1/2"NPT TY3221 .... Pendent 5.6K, 1/2"NPT TY4121......Upright 8.0K, 3/4"NPT TY4221 .... Pendent 8.0K, 3/4"NPT TY1121 is a redesignation for S1879 and G8973. 1Y1221 is a redesignation for S1880 and G8971. TY3121 is a redesignation for S1864 and G8974. TY3221 is a redesignation for S1865 and G8972. TY4121 is a redesignation for S1866 and G8174. TY4221 is a redesignation for S1867 and G8172. OCTOBER 2013 TFPI3O AS 160174 2714 LOKER AV WEST TFPI3O Page 2 of 6 * Temperature rating ** Pipe thread connections per 1 - Frame 5 - Link 7 - Button Is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Strut Assembly 8 - Seal Deflector, special request. PLATE SEATING 3 - Deflector* 6 - Ejection 9 - Bushing DEFLECTOR * I) 2-11/1 (68,3 mi 7/16° I (11,1 mm) I NOMINAL I MAKE-IN $ 1/2 NPP* I WREI - FLANGES SURFACE 4 - Hook Spring 2 11/16 / I WREN ___ __ 68,3 20 508 mm) AREAS 1( - °[_"___/ mm) L STYLE 20 1 I \ \tI RECESSED J ESCUTCHEON * 2-7/8 (73,0 mm) DIA. 3* UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TYI12I) AND PENDENT (TY1221) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT * Temperature rating ** Pipe thread connections per 1 - Frame 5 - Link 7 - Button is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Strut Assembly 8 -Seal Deflector, special request. PLATE SEATING 3 - Deflector* 6 - Ejection DErLECTOR * 2-huE (68,3mr 7/16 (11.1 mm) I NCMINAL J MAKE-IN 1/2 NP I** t WRENCH FLANGES SURFACE 4 - Hook Spring _________ ___ _________ AREA 8 2-11/16° _______ (50,8 mm) 5 2 (68,3 mm) 6 7 I 1) WRENCH - 1 2 STYLE 20 RECESSED 4 I I ________ ESCUTCHEON DEFLECTOR * 2-7/8" (73 mm) DIA. UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY3121) AND PENDENT (TY3221) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT DEFLECTOR * UPRIGHT CEILING PLATE SEATING SURFACE /WRENCI AREA 16° nm) CROSS SECTION 2-13/16 (71,4 mm) 1/20 (12,7 mm) NOMINAL MAKE-IN WRENCH FLANGES DEFLECTOR* PENDENT TFPI3O Page 3 of 6 1 - Frame 6 - Ejection 2 - Strut Spring 1 - Deflector* 7 - Button 4-Hook 8-Seal 5 - Link 8 Assembly * Temperature rating Is indicated on Deflector. 2 ** Pipe thread connections per ISO 7-1 can be provided on special request. 3* FIGURE 3 QUICK RESPONSE SERIES TY-FRL UPRIGHT (TY4121) AND PENDENT (TY4221) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Techv,iical Data Approvals UL and C-UL Listed. FM, NYC, and LPCB Appro d. (Refer to Table A for complete approval information includ- ing corrosion rnsstant status.) Maximum Vcorinj Pressure 175 psi (12,1 1: r) Discharge K = 2.8 GP' )Si1/2 (40,3 LPM/bar1/2) K = 5.6 GP!;' si1 '"2 (80,6 LPM/barl'2) K = 8.0 GPM siL'2 (115,2 LPM/bar1/2) Temperatu 'fl:'ngs Refer to Tab! A Finishes Sprinkler: P ' ThbIe A Recessed E ;con: White Coated, Chrome PIa" r Prass Plated Physical C! ateristicS Frame..... .. . ............. Bronze Strut ...... ................. Monel Deflector .................... .Bronze Hook ...... ................... Monel Link Assembi ..................Nickel Ejection Sprin .................Inconel Button ........ .............. Bronze Seal .....................TEFLON Bushing (2.81: ..............Brass Operation The fusible link (heat collector) assem- bly is comprised of two halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, allowing the sprinkler to operate. Design Criteria The TYCO Series TY-FRL Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard instal- lation rules recognized by the appli- cable Listing or Approval agency (e.g., UL Listing is based on the require- ments of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 20 Recessed Escutcheon, as apptable, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRL Sprinklers must be installed in accordance with this section. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft./lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft./lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprin- kler inlet and cause leakage or impair- ment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-FRL Pendent and Upright Sprinkler Installation The Series TY-FRL Pendent and Up- right Sprinklers must be installed in accordance with this section. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 9 Sprinkler Wrench (Ref. Figure 6). With reference to Figures 1, 2, and 3, the W-Type 9 Sprinkler Wrench is to be applied to the wrench area. TFPI3O Page 4 of r -. SPRINKLER FINISH Series TY-FRL Recessed Pendent Sprinkler Installation The Series TY-FRL Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 20 Mounting Plate, as applicable, over - K TYPE TEMP. RATING FRAME COLOR CODE NATURAL BRASS I CHROME PLATED - 21) 165°F (74°C) - ThIT Unpainted 212°F(100°C) White 2.8 1/2" NPT 1, 2, 5 the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into U' HT l _1) 1650F(740C) Unpainted 212°F (100°C) White - the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 12 Recessed Sprinkler Wrench (Ref. Figure 7). With reference to Figure 1, or 2, the W-Type 12 Recessed Sprin- - - F C ED - (TY1', L Style 20) 165°F(740C) Unpainted 212°F (100°C) White N AT 1650F(740C) Unptinted 1,2,3,4,5 212°F (100°C) C 1,2, 35 5.6 1/2 NPT kier Wrench is to be applied to the sprinkler wrenching flanges. Step C. After the ceiling has been in- - 165°F (74°C) Urn tinted 1,2,3,4,5 212°F (100°C) V,hitc 1,2,3, 5 D 165°F(740C) Unr;nled 1,2,5 stalled or the finish coat has been ap- plied, slide on the Style 20 Escutch- 212°F (100°C) (TY3 1 kyle 201 \::ilc eon over the Series TY-FRL Sprinkler and push the Escutcheon over the Mounting Plate until its flange comes T 165°F(740C) UrnirRed 8.0 3/4" NPT 212°F (100°C) V/hue 1,2,3,5 in contact with the ceiling. . - 165°F (74°C) U" nkd 1 212'F(1000C) NOTES: Listed by I s Labort1ories, Inc. (UL) as Quick sponse Sprinklers Listed by I i Labor tories Inc. for use in Car; ia C-UL as Quick Response Sprinklers. Aparovod tutuat esozi;ch Corporation (F' Thick Response Sprinklers. 4) Ap roved l'rov)n Certification Board i Ilef. No. 094a/03) as Quick Response Sp (5) Approvee of New York under MEA 112-04-I-. TABLE A 30RATORY LISTINGS APt) APPROVALS TFPI3O Page 5 of 6 ,2 mm) .OF KLER NG M' ITING FIGURE 4 SER!r , ,'i?L (TY1221) RECESSE" PENDENT SPRINKLER ASSI C VITH TWO -PIECE 1/2 IN 'H TOTAL ADJUSTMENT STYLE ' ESSr' L"CUTCHEO!"! 2 K-FACTOR, 1/2 INCH NPT 2-7/8 DIA. 1/2° (12,7 mm) (73,0 mm) 1/4" (6,4 mm) 2-1/4" DIA. MOUNTING L572 mm _-- PLATE (3,2 mm) 1-3/4° (44,5 mm) 1-1/2"T38-71 mm) FRL WRENCH RECESS 1/8' 2-7/8 DIA. 1/2k (12,7 mm) ' ruin) 73,(.) mn) 1/4° (6,4 mm 2-in" YA. MOUNTING ftLCI1 j57.2 rnn) __ PLATE NG I (3,2 mm) / E Th'-FRL FIG Ih12 :7,11- (TY3221) RECES SE!) PENDENT SPRINKLER (H TWO-PIECE 1/ IN "TOTAL ADJUSTMENT ,SEr)ESGUTCHC( '5. <-FACTOR, 1/2 INCH NPT PUSH WRENCH UP TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 7 W-TYPE 12 RECESSED SPRINKLER WRENCH SEP ASS— STYLE 2 Car Main The TYCO FFL Sprinklers must be m: rid sorviced in accordance cicn. Before cbs •rc!ection sys- tern mai:i for rn" te- nance wk tC(iC vs- tern th?it cc nut down thi at" c) ' tern rr er auh-: 'ho may H; must be notift Absence c4 lie :n, which is used to c; n nay delay the Lu. tc peraIon in afire situai' '-irs that are found to be leaking 'biting visible signs of corrosion u no replaced. ut(, atic sprinklers must never be raink;d, plated, coated or otherwise Iterccd after leaving the factory. Modi- ed r over sprinklers must be oplcc r;od. '-ar nst be exercised to avoid dam- g€ he sprinklers -before, during, r installation. Sprinklers dam- dropping, striking, wrench page, or the like, must be he ner is responsible for the in- PC n, testing, and maintenance I U i fire protection system and de- ice in compliance with this docu- ier well as with the applicable ta :ds of the National Fire Pro- tection Association (e.g., NFPA 25), in addition to the standards of any oth- er authorities having jurisdiction. The installing contractor or sprinkler man- ufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified In- spection Service in accordance with local requirements and/or national codes. a' di- I :rt fy dint) 'ecify) 'peof Ci i, ench. TPF13 Page 6 of t HN5B-x:. X - XXX SPRINKLER 1 NATURAL BRASS 2'kifl) 9 CHROME PLATED 'r Iv: rY TABLE B 7 r ENDENTAND UPRIGHT SPRINKLERS T NUMBER SELECTION TEMPERATURE RATING 165 165°F (74°C) 212 212-F (100-C) Ord Proet Contact your ( ability. When 2 cate the quIt Number( Sprinkler A c Thread Cc'r Specify: SIN). (spr ci right. Per Sprinkler k temp rat finish,, P/N ( Recessed Er Ll Specify: S cutchoor (specify*) *Refer to Sprinkler Spefy: P/N .3-0 Spc'r fy:' '- c P/N 3-7 Cop' ight lEFt Jist .tTSf 1 nrrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 re Pro ct .LP. reserved. tqco )uPontC ;c; On. Fire Protection Products tq ca Fire Protection Products Worldwide www.tyco4ire.com Contacts Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar) *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/bar112) FEBRUARY 2014 Temperature Rating 135'F(57-0) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 \ / WRENCH FLATS DEFLECTOR * i- 2-7/8" (73,0 mm) 01k PENDENT RECESSED PENDENT TFPI72 Page 2 of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression Screw ESCUTCHEON PLATE 1/2" 7/16' (11,1 mm) 6 - Deflector * DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON CROSS SECTION 1 7/16' (11,1 mm) NOMINAL _Icy MAKE-IN 2" (50,8 mm) 1/2" NPT** UPRIGHT FIGURE 1 SERIES TY-FRB UPRIGHT (i313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS. / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING SURFACE/ 5/8" (15,9 mm) FLUSH 3/8±5/16' (9,5±7,9 mm) I'- MOUNTING (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4"(19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY 'TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4' (7,9±6,4 mm) I 1/2" (12,7 mm) 1 _____________ FLUSH SURFAcE/2 mm) \ 1/8" J I MOUNTING CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8U (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77_XXX_XXXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 370 5.6K UPRIGHT (1/2 NPT) TY313 - 371 5.6K PENDENT (1/2 NPT) 1Y323 Use suffix 1° for ISO 7-1 connection; 1 NATURAL BRASS 3 PURE WHITE (RAL9010)°° POLYESTER SIGNAL WHITE (RAL9003) POLYESTER 9 CHROME PLATED for example, 77-370-4-175-I Eastern Hemisphere sales on ly 135 135°F(57°C) 155 155°F(68°C) 175 175°F (79°C) 200 200'F(93-0) 286 286°F (141°C) TABLE A SERIES 7Y-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-tire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tyco TEFLON is trademark of The DuPont Corporation. Fire Protection Products --.-.---- --_-_..-;---- / •': . 'I . . ... 41 llu( ¶ f II&\ \ L \ ê Z.44 TTh\I ,- Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 __ Class 300 Sizes W'-l' (6-25 mm) Sizes 11/4°-2° I2T51 mm.) Sizes 2Vx"-3 (54-76 mm) .sit baf. psi bar psi" bar psi. bar. -200 -28.90 to to 1500 65.60 300 20.7 2,000 137.9 1,500 103.4 1,000 68.9 2000 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 2500 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 3000 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 350° 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 385 26.5 550° 287.8 - - 300 20.7 300 20.7 300 2077 Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature __ Pressure Class 150 Class 250 Class 300 ft .' (C) psi bar psi bar psi bar -200 to 1500 -28.90 to 300 20.7 65.60 500 34.5 600 41.4 2000 93.30 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 185 12.8 360 24.8 460 31.7 3500 176.70 150 10.3 315 21.7 415 28.6 4000 204.40 110 7.6 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 22.4 5000 260.00 - - 180 12.4 280 19.3 550° 287.80 - - 130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not Intended for use where temperature exceeds 450°F c®us APPROVED For Listings/Approval Details and Limitations, visit our website @ www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. L bE I t 111 Anvil Class 150/300 Malleable Iron Fittings conform to ASME 616.3 and Unions conform to ASME B16.39. ALL ELBOWS & TEES W' (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) [Oiz v4jI Dyfla'-FIow,, MCQAT0 High Strength Steel Pipe Exceptional hydraulics Lightweight and easy to install Available factory roll grooved M-COATID UL and cUL listed FM approved > The original high-strength I 1. NPS NominaiLD. Wt. Wt. (H20 Filled) . CRR In; mm in; mm . Lbs/pt; kg/rn th$/Ft kg/rn Uhthaded 1" 1.191 0.830 1.31 , 2.41 25 . , 30.3 . I ':. 1.2 195 1114" 1.536 1.059 1.87 1.55 32 390 1 '78 r 1½" 1,728 1.667 2.71 3.44 40 . 43.9 .., '74.03 - 2 2.203 2.104 3.79 2.78 50 56.0 ' .. 3.1 .' 5.64 , - 21h" 2.703 2.564 5.10 1.60 "p65 687 3.8 759 - 3 3.314 3.387 7.18 1.48 75 84.2 - .5.0 4 4.310 4.473 10.86 1.00 109.5" FBe c@ < > Superior Coating light wall sprinkler pipe with superior hydraulics. Dyna-Flow - M-COAVI is the "original" high-strength light wall sprinkler pipe. With outstanding hydraulic capabilities, Dyna-Flow - M-COAT is recognized as the most popular alternative to Schedule- 10 pipe. Lightweight and easy to cut Dyna-Flow - M-COAT is a valuable addition to any fire protection system. With an inside diameter (ID) up to 11% larger than Schedule-40 and up to 7% larger than Schedule -10, Dyna-Flow - M-COAT pipe hydraulics are exceptional. Larger ID's enable Dyna-Flow - M-COAT and related components to be down-sized within the system, increasing the potential for job cost savings. For complete Hazen Williams charts, refer to "Dyna-Flow - M-COAT Hydraulic Data Tables". Dyna-Flow - M-COAT pipe has metallurgical properties that provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There are no special processes or equipment needed for fabrication and installation. Dyna-Flow - M-COAT products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable and acts as an excellent primer while resisting weather and UV degradation from outdoor storage. The internal surface of all black Allied Tube & Conduit fire sprinkler pipe products are coated with M-COAT an advanced MIC coating that is FBCTM system compatible for hybrid sprinkle systems. FBC system compatible indicates that this product has been tested, and is monitored on an ongoing basis, for chemical compatibility with FlowGuard Golds, BlazeMaster®, and Corzan® pipe and fittings.* > American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. > Specifications & Approvals Dyna-Flow - M-COAT pipe is manufactured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA- 14. All sizes of Dyna-Flow - M-COAT are UL and cUL listed and FM approved. Dyna-Flow - M-COAT is UL and cUL listed for use with roll grooved, plain-end and welded joints for wet, dry, pre-action and deluge systems. It is FM approved for roll grooved, plain end and welded joints for wet systems. Dyna-Flow - M-COAT is available "hot-dip" galvanized** and has been specifically approved by FM for dry system uses. Dyna-Flow - M-COAT complies with NFPA 13 and is rated at 300 psi working pressure. * FBCTM, FlowGuard Gold, BIazeMaster, and Corzan are licensed trademarks of The Lubrizol Corporation ** Must be ordered in 10 bundle increments Customer Service (800) 882-5543 Fax: (800) 659-7730 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. www.afliedtube-sprinkler.com e 600 Dean Sievers Place TUBE & CONDUIT' Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 004atkore NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR CRR mm In; riin thslFl kg/rn Lbs/Ftkm Unthreaded Thaded 1.080 1.330 1.75 11.39 1.00 25, 2.60 — — 1'/4" 1.408 1.870 2.54 9.50 1.00 32 p358 378 - - 1½" 1.639 2.290 3.22 9.14 1.00 40 416 2.104 3.050 4.57 8.41 1,00 150 534 45 680 1~~ CO <~> *ppoflD Full Line Sch-40 Replacement Dyna-Thread' sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-f it applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Thread pipe is manufactured to meet: ASTM A 135, Type E Grade A, and is in compliance with NFPA-1 3. All sizes of Dyna- Thread are rated at 300 psi working pressure. Dyna-Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Dyna-Thread can be "hot-dip" galvanized* to meet FM requirement for dry systems. Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). * Must be ordered in 10 bundle increments. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: CuthnefSevice (800) 8S5543 Fax: (800) 659-7730 •. www.alhedtue-sprinktercom -. C ie 16100 S LathropAve. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT" Hatvey,1L60426 Philad&Phia,PA 19154 . Phoenix, AZ 85009 Morrisville,PA 19067, FireLock® Outlet-T ® ILPCBJ SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 34, and 1715, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1'A through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade 'E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. ______ Submitted By Spec Sect - Para Location Date Approved Date www.victaulic.com vlclAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV ( /tauIic 10.52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-I STYLE 922 DIMENSIONS ___ ,-;---1 I 14 11/16 1.30 1.83 1.10 3.87 2.56 10 15 30.2 330 46521.9 98.365.0 0.45 T " 34 PM 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 983650 0.50 W 1 1 t46 1.52 2.18 110 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 1 98.3 65.0 0.54 1½ x ½ I 1 /6 1.42 1.95 1.22 4.08 2.56 I 1.2 40 15 30.2 1 36.1 49.5 31.0 103.6 650 i 0.54 34 1 IA6 1.40 1.95 1.22 4.08 1 2.56 1 1.2 -20 30.2 35.6 49.5 31.0 103.6 650 034 1 11/16 1.64 2.30 122 408 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 . 65.0 0.59 2 x ½ 13/i6 1.66 2.19 1.46 460 2.56 13 50 15 30.2 42.2 55.6 371 116.8 650 059 Y4 43,44 1.64 2.19 1.46 4.60 256 14 20 30.2 41.7 55.6 371 1168 650 0.64 1 43/4 1.88 2.54 1.46 460 2.56 15 25 30.2 478 643 37.1 116.8 65.0 0.68 2½ x V2 T 1A6 1.91 2.4'l 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 1372 65.0 0.73 ~ 1 34 1.89 2.44 1.71 5.40 256 1.6 20 302 48.0 62.0 43.4 137.2 65.0 0.73 1 1 3/4 1 2.13 2.79 1.71 1 5.40 2.56 1.6 25 1 02 54.1 70.9 4A 137.2 - 65.0 0.73 1h 1A6 1.91 244 1.71 550 2.56 1.6 76.1 mm X 15 30.2 48.5 620 43.4 139.7 65.0 073 4........................................................ ........ ..,. - 34 13M 1.89 2.44 1.71 550 2.56 1.6 20 30.2 480 62.0 434 139.7 650 073 13M 213 2.79 1.71 550 2.56 1.7 25 30.2 54.1 70.9 43.4 1397 65.0 0.80 t Victauhc female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com 1i e VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. Aic ____________ 10.52 2 RIFV ( IPS CARBON STEEL PIPE HOLE CUT PRODUCTS FireLock® OutIetT STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com \JtauIic vIcTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RFV ( STYLE 922 INSTALLATION Reference should always be made to the 400 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV UPDATED 12/2009 viclAulic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 'j49 tauiic P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1 thru 4 inch pipe LISTED FOR STEEIJCPVC II2&3!4 Inch pipe 5 thru 8 Inch pipe NFPA 13 PIPE ROD I Wt 5 WT.+250 UL TEST LOAD 1 3/8 30.75 403.75 750 I 1/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 1 76.95 1 634.75 750 2 112 3/8 118.35 841.75 850 3 3/8 162.30 1061.50 1050 4 3/8 248.00 1480.00 1500 5 349.45 199675 2000 6 U2 476.35 3535 2650 8 1/2 711.00 1 3805.00 4050 SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - c®00 050(0 203-EX 2551 1"- 8" Approval guide - 1 "- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-17lE, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 131), these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 PIPE A B I 1.8793 2.6259 TT 1114 213B2 2.7950 1 U2 22673 2-9140 A B 2 2.8048 3.2518 I 21(2 3.4920 4.1150 3.7845 4.4311 .4. " 4.3582 4.9M ---- 6 8.8464 6.0160 7.5166 6.3200 L1 Fcsn P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - Sus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES- * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific ,lvCONproducts are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCONwuU NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by 4FCON. AFCON shalt NOT he liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when nnn-AFCONproducts have been, or are used. 1/08 Product Features No pie-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods, Reduces installation cost. Made in the U.S.A. 1/4 6002957 iST 100 1/4x1 670 210 (7116' QSB) ~5125j 1/4 8003957 GST 200 1I4x2 1760 (Fir) 25 125 _'j/4 094957 GTr. /43 ::: 3/8 8006951 GST.75 114x314 564 (3/4 Ply) 25 125 rr.'- 8007957 GST1O V4x 1' 210 (7n OSS) 300 25 126 670 L39?k~ A. 3/8 8008957 GST 20 1/4 a 2 1760 (Fir) 850 1475 25 125 çj 'r3/5 8066925 GST2O-90114x2 17€0(flr) 850 Th2fl 3/8 8009925 GST25-380 318x2-112 2113 (F) 1500 25 125 -. onr 10Th 2%1 = 318 8069925 GST30-SS 1/4x3 2060 (Fir) 25 125 Part#8113910 L :: _3/8L 801)925 GST4O X4T FrLTT i: 318 8012925 GST O 114x6 2230 (Fir) 25 125 - 11Z' 8043925 : T2 7V4x2 J70(r)___: 125j1 1I2 8014925 GST2.5-350 3/8x2-112 2113 (Fir) 25 125 85925 :ST3 275(F 112' 8016925 GST4 114x4 2180 (Fir) 25 125 1/2 8925 G$T6 J #14 SW Red Nut Dover Part #8114910 Product Features Elimina:es distortion of threaded rod. • Saves time from traditional methods. Accomnodates up to 3 /2" x 12 pitch roof. • Reduces installation cost. Allows 17 deflection from vertical. • Made in the U.S.A. 4.S> 3/8 8141957 SH-G5730 114x3 1720 (Fir) 1500 1475 25 125 411 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The wit drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driverfor installations. Not less than 2' nominal width (1-1121 up to 3-112' pipe; not less than 3' (2-1/2') nominal width 4' & 5 pipe 4 Minimum 2-1/2' from bottom for branch toes. Minimum 3' from bottom for main lines. Exception: This requirement shall not apply to 2' or I thicker nailing ships resting on top of steal beams. IN Floor Joist Product Features 'No pre-drilling required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost. 'Made in the U.S.A. 6- #14 SW Red Nut Driver Part #8114910 .WG :00 25 5 1/4' 0019957 SWG 200 114x 2' 1725 (Fir)______ 25 125 :SK & 3/8' 8021957 SWG20 114x2 1725 (Fir) 1050 25 125 tL3iB813925 !G2os. j85a T125Th $3.. 3/8' 8022925 SWG 25-380 3/8 x 2-1/2' 2249 (Fir) 1500 25 125 r88O2392S In 0 Insert the appropriate nut driver into a 3/8' or 1/2"portable drill Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4', 3/8', 1/2' or metric all thread rod, bolt stock. (The 112" requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel Insert the appropriate nut Over into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14SW(red) nut driver (pIn 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in puriin steel. r..'a. --` - 5-W SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.