HomeMy WebLinkAbout2728 LOKER AVE W; ; FPC2020-0123; Permitccityof
PERMIT REPORT Carlsbad
Print Date: 12/02/2020 Permit No: FPC2020-0123
Job Address: 2728 LOKER AVE W, CARLSBAD, CA 92010-6603 Status: Closed - Finaled
Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers
Parcel #: 2090812900 Track #: Applied: 07/17/2020
Valuation: $24,787.76 Lot #: Issued: 07/28/2020
Occupancy Group: Project #: Finaled Close Out: 07/29/2020
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check#: Inspector:
Plan Check #: Final Inspection:
Project Title:
Description: COPAN DIAGNOSTICS -SPRINKLER TI (2 HEADS)
FPContractor:
COSCO FIRE PROTECTION INC
1075 W LAMBERT RD
BREA, CA 92821-2944
(858) 444-2000
FEE AMOUNT
FIRE NFPA 13 or 13R System 6 heads or less $125.00
Total Fees: $125.00 Total Payments To Date: $125.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov
f:rc 20
O •" I cosco .1S..II.
00 . I. I'• Fire Protection
San Diego Branch Office
4990 Greencraig Lane
San Diego, CA 92123
(858) 444-2000 fax: 444-2056
CA Lic.: C-16 #577621
www.coscofire.com
MATERIAL SUBMITTAL
Date: 7-13-20
COPAN
DIAGNOSTICS
2728 LOKER AVE. WEST
CARLSBAD, CA.
All material submitted, may be substituted
by material of equal performance & design, &
shall be deemed acceptable by purchaser.
Submitted by: FELIPE A.
Los Angeles • San Francisco • Orange 0 Fresno • San Diego • Seattle
a-i o
tqca® Worldwide www.tyco-fire.com Contacts I
Series TYFRB - 2.8,42,5.6, and 8.0 K-Factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General
Description
The TYCO Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent,
and Recessed Pendent Sprinklers
described in herein are quick response,
standard coverage, decorative 3 mm
glass bulb-type spray sprinklers. They
are designed for use in light or ordinary
hazard, commercial occupancies such
as banks, hotels, and shopping malls.
The TY-FRB Recessed Pendent Sprin-
kler, where applicable, is intended for
use in areas with a finished ceiling. This
recessed pendent sprinkler uses one of
the following Recessed Escutcheons:
A two-piece Style 10 (1/2 in. NPT)
or Style 40 (3/4 in. NPT) Recessed
Escutcheon with 1/2 in. (12,7 mm) of
recessed adjustment or up to 3/4 in.
(19,1 mm) of total adjustment from
the flush pendent position.
A two-piece Style 20 (1/2 in. NPT)
or Style 30 (3/4 in. NPT) Recessed
Escutcheon with 1/4 in. (6,4 mm) of
recessed adjustment or up to 1/2 in.
(12,7 mm) of total adjustment from
the flush pendent position.
The adjustment provided by the
Recessed Escutcheon reduces the
accuracy to which the fixed pipe drops
to the sprinklers must be cut.
Corrosion-resistant coatings, where
applicable, are utilized to extend the
life of copper alloy sprinklers beyond
what would be obtained when exposed
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 10
to corrosive atmospheres. Although
corrosion-resistant coated sprinklers
have passed the standard corrosion
tests of the applicable approval agen-
cies, the testing is not representative
of all possible corrosive atmospheres.
Consequently, it is recommended that
the end user be consulted with respect
to the suitability of these coatings for
any given corrosive environment. The
effects of ambient temperature, con-
centration of chemicals, and gas/
chemical velocity, should be consid-
ered, as a minimum, along with the cor-
rosive nature of the chemical to which
the sprinklers will be exposed.
An intermediate level version of the
Series TY-FRB Pendent Sprinklers
is detailed in Technical Data Sheet
TFP356. Sprinkler Guards are detailed
in Technical Data Sheet TFP780.
NOTICE
The Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent,
and Recessed Pendent Sprinklers
described herein must be installed
and maintained in compliance with
this document and with the applicable
standards of the National Fire Protec-
tion Association (NFPA), in addition to
the standards of any authorities having
jurisdiction. Failure to do so may impair
the performance of these devices.
The owner is responsible for maintain-
ing their fire protection system and
devices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted with
any questions.
NFPA 13 prohibits installation of 1/2 in.
NPT sprinklers with K-factors greater
than 5.6 in new construction. They are
intended for retrofit in existing sprinkler
systems only.
JULY 2018
Sprinkler
Identification
Number (SIN)
TY1131 ... Upright 2.8K, 1/2 in. NPT
TY1231.. Pendent 2.8K, 1/2 in. NPT
TY2131 . . . Upright 4.2K, 1/2 in. NPT
TY2231.. Pendent 4.2K, 1/2 in. NPT
TY3131 . . . Upright 5.6K, 1/2 in. NPT
TY3231.. Pendent 5.6K, 1/2 in. NPT
TY4131 . . . Upright 8.0K, 3/4 in. NPT
TY4231.. Pendent 8.0K, 3/4 in. NPT
TY4831 ... Upright 8.0K, 1/2 in. NPT
TY4931.. Pendent 8.0K, 1/2 in. NPT
Technical
Data
Approvals
UL and C-UL Listed
FM, LPCB, and NYC Approved
Refer to Table A and B for complete approval information including corrosion-resistant status.
Maximum Working Pressure
Refer to Table C
TFPI7I
C
TFPI7I
Page 2 of 10
1 - Frame 3 - Sealing 5 - Compression
2 - Button Assembly Screw
4 - Bulb 6 - Deflector*
7 - Bushing
** Pipe thread connections per
ISO 7-1 can be provided on ESCUTCHEON special request. PLATE SEATING
SURFACE
RX
__________________________________
1 2-1/4
(57,2 mm)
v
2-3/16
(55,6 mm) 1 1-9/16
(39,7 mm)
1/2 NPT** t WRENCH STYLE 10 or 20
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON
* Temperature rating
is indicated on
Deflector.
7/16
(11,1 mm)
NOMINAL
MAKE-IN
CROSS SECTION
2-7/8 (73,0 mm) DIA.
RECESSED PENDENT
FIGURE 1
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TV1131) AND PENDENT (TY1231) SPRINKLERS
2.8 K-FACTOR, 1/2 IN. NPT
* Temperature rating ** Pipe thread connections per
is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING
SURFACE
1
7/16
NOMIN
MAKE-IN
AL
(55,6 mm)
2-3/16 1-1/2
(11,1 mm)
2-3/1 6
(38,1 mm) (55,6 mm) .
1/2 NPT** f WRENCH STYLE 100r20
FLATS RECESSED
1 - Frame 3 - Sealing 5 - Compression
2 - Button Assembly Screw
4 - Bulb 6 - Deflector*
F- 2-7/8 (73,0 mm) DIA. -H
UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION
FIGURE 2
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS
4.2 K-FACTOR, 1/2 IN. NPT
S
Discharge Coefficient
K=2.8 GPM/psi½ (40,3 LPM/bar½)
K=4.2 GPM/p5i½ (60,5 LPM/barY)
K=5.6 GPM/psi' (80,6 LPM/bar")
K=8.0 GPM/psi/2 (115,2 LPM/bar½)
Temperature Rating
Refer to Table A and B
Finishes
Sprinkler: Refer to Table D
Recessed Escutcheon: Signal or Pure White,
Grey Aluminum, Jet Black, Chrome Plated,
or Natural Brass
Physical Characteristics
Frame ............................Bronze
Button ......................Brass/Copper
Sealing Assembly. . Beryllium Nickel w/TEFLON
Bulb ...............................Glass
Compression Screw .................Bronze
Deflector ...................Copper/Bronze
Bushing (K=2.8) ....................Bronze
Poly-Stainless
Physical Characteristics
Frame ............................Bronze
Button ................L316 Stainless Steel*
Bulb ...............................Glass
Compression Screw .....L316 Stainless Steel*
Deflector ...................Copper/Bronze
Sealing Assembly. Gold Plated Beryllium Nickel
w/TEFLON
Type L316 stainless steel (IJNS 31603) per ASTM
A479/479M or BOON 1008 WN1.4404.
Operation
The glass bulb contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The TYCO Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent,
and Recessed Pendent Sprinklers are
intended for fire protection systems
designed in accordance with the stan-
dard installation rules recognized by
the applicable Listing or Approval
agency, such as UL Listing based on
the requirements of NFPA 13 and FM
Approval based on the requirements
of the FM Global Loss Prevention Data
Sheets. Use only the style 10, 20, 30, or
40 Recessed Escutcheon, as applica-
ble, for recessed pendent installations.
* Temperature rating
is indicated on
Deflector.
** Pipe thread connections per
ISO 7-1 can be provided on
special request.
2-7/8' (73,0 mm) DIA.
RECESSED PENDENT CROSS SECTION
TFPI7I
Page 3 of 10
ESCUTCHEON
PLATE SEATING
SURFACE
I
7/16"
NOMINAL 2-MAKE-IN
(11,1 mm)
(55,6mm)
2-3/16'
(55,6 mm)
1/2' NPT** I WRENCH STYLE 10or20
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON
1 - Frame 3 - Sealing 5 - Compression S
2 - Button Assembly Screw
4 - Bulb 6 - Deflector*
ALL FINISHES EXCEPT POLY-STAINLESS
WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature
FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated
SURFACE 4 - Bulb 6 - Deflector* on Deflector.
JJN(OMINAL
7/16'
1,1 mm)
2-3/16"
_F
AKE-IN (55,6 mm)
/2"2-3/16'____ (55,6 mm) mm) I (38,1
STYLE 10
RECESSED
UPRIGHT PENDENT ESCUTCHEON
ril
C:
4
f6
=
RECESSED PENDENT
POLY-STAINLESS FINISH ONLY
FIGURE 3
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS
5.6 K-FACTOR, 1/2 IN. NPT
Installation
The TYCO Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent, and
Recessed Pendent Sprinklers must
be installed in accordance with this
section.
General Instructions
Do not install any bulb type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 in.
(1,6 mm) for the 135°F (57°C) and
3/32 in. (2,4 mm) for the 286°F (141°C)
temperature ratings. A leak-tight 1/2 in.
NPT sprinkler joint should be obtained
by applying a minimum-to-maximum
torque of 7 to 14 lb-ft (9,5 to 19,0 Nm).
A leak tight 3/4 in. NPT sprinkler joint
should be obtained with a torque of
10 to 20 lb-ft (13,4 to 26,8 N.m). Higher
levels of torque can distort the sprinkler
inlet and cause leakage or impairment
of the sprinkler. Do not attempt to com-
pensate for insufficient adjustment in
the escutcheon plate by under- or over-
tightening the sprinkler. Re-adjust the
position of the sprinkler fitting to suit.
Series TY-FRB Upright and Pendent
Sprinklers
The Series TY-FRB Upright and
Pendent Sprinklers must be installed
in accordance with the following
instructions:
Step 1. Install pendent sprinklers in the
pendent position. Install upright sprin-
klers in the upright position.
Step 2. With pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type 6
Sprinkler Wrench (Ref. Figure 14). With
reference to Figure 1 to Figure 5, apply
the W-Type 6 Sprinkler Wrench to the
sprinkler wrench flats.
Series TY-FRB Recessed Pendent
Sprinklers
The Series TY-FRB Recessed Pendent
Sprinklers must be installed in accor-
dance with the following instructions:
Step 1. After installing the Style 10, 20,
30, or 40 Mounting Plate, as applica-
ble, over the sprinkler threads and with
pipe-thread sealant applied to the pipe
threads, hand-tighten the sprinkler into
the sprinkler fitting.
Step 2. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Ref.
Figure 15). With reference to Figure 1 t
4, apply the W-Type 7 Recessed Sprin-
kler Wrench to the sprinkler wrench
flats.
Step 3. After the ceiling is installed or
the finish coat is applied, slide on the
Style 10, 20, 30, or 40 Closure over
the Series TY-FRB Recessed Pendent
Sprinkler and push the Closure over the
Mounting Plate until its flange comes in
contact with the ceiling.
C
UPRIGHT PENDENT
STYLE 40
RECESSED
ESCUTCHEON
2-7/8" (73,0 mm) DIA.
RECESSED PENDENT CROSS SECTION
2-7/8 (73,0 mm) DIA.
RECESSED PENDENT CROSS SECTION
TFPI7I
Page 4 of 10
1 - Frame 3 - Sealing 5 - Compression
ESCUTCHEON 2 - Button Assembly Screw
PLATE SEATING 4 - Bulb 6 - Deflector*
SURFACE
1/2
(12,7 mm)
NOMINAL I
_
MAKE-IN
2-1/4
T(57 m
51/11
m)
1-9/16 (57,2 mm) (39,7 mm)
-
3/4 NPT' f WRENCH STYLE 30 or 40
FLATS RECESSED
UPRIGHT PENDENT ESCUTCHEON
ALL FINISHES EXCEPT POLY-STAINLESS
WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature
FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated
SURFACE 4 - Bulb 6 - Deflector* on Deflector.
POLY-STAINLESS FINISH ONLY
FIGURE 4
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS
8.0 K-FACTOR, 3/4 IN. NPT
S * Temperature rating ** Pipe thread connections per
is indicated on ISO 7-1 can be provided on
Deflector, special request.
CEILING PLATE 1 - Frame 5 - Compression
SEATING SURFACE 2 - Button Screw
3 - Sealing 6 - Deflector *
Assembly
4 - Bulb
2-1/4
(57,2 mm)
* Temperature rating is
1-9/16 indicated on Deflector.
(39,7 mm)
** Pipe thread connections
per ISO7-1 can be
* 6 provided on special
request.
CROSS SECTION
\ 7/16 I
(111 , mm) I
NOMINAL
Ll MAKE-IN I
I I V 3/16"
(55,6 mm
,
1/2 NPT** I WRENCH
FLATS UPRIGHT PENDENT
FIGURE 5
QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS
8.0 K-FACTOR, 1/2 IN. NPT
0
TFPI7I
Page 5 of 10
S 2-7/8 DIA.
5/8±1/4' (73,0 mm) I 3/4" (19,1 mm)
(15,9±6,4 mm) I 1/4' (6,4 mm) / FACE OF
2-1/4' DIA.
(57,2 mm) MOUNTING SPRINKLER PLATE
FITTING
(3,2 mm) r - ra~
MOUNTING /
SURFACE,/"
CLOSURE SERIES 1-5/16" (33,3 mm)I
TY-FRB 13/16' (20,6 mm)
FIGURE 6
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 IN. NPT
2-7/8' DIA.
-
5/8±1/4"
(73,0 mm) 3/4' (19,1 mm)
(15,9±6,4 mm) 2-1/4" DIA. I 1/4' (6,4 mm)
/ FACE OF (57,2 mm) MOUNTING
SPRINKLER
PLATE
FITTING
(3,2 mm)
\%
MOUNTING
SURFACE
SERIES 1-1/4"(31,8mm) CLOSURE TY-FRB 3/4" 19,1 mm)
FIGURE 8
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 IN. NPT
2-7/8' DIA.
(73,0 mm) 1/2±1/8" I 1/2' (12,7 mm)
(12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm)
MOUNTING
SPRINKLER PLATE
FACE OF / [572 mm)
4P777-7
FITTING
1/8"
(3,2 mm)
\%!_
SURFACE
t MOUNTING
CLOSURE SERIES (33,3 mm)
TY-FRB 1-1/16' (27,0 mm)
FIGURE 7
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
2.8 K-FACTOR, 1/2 IN. NPT
- 2-7/8" DIA.
(73,0 mm) 1/2±1/8" 1/2' (12,7 mm)
(" DIA. 12,7±3,2 mm) 2-1/4 1/4" (6,4 mm)
I FACE OF mm)
m
MOUNTING SPRINKLER PLATE
FITTING
1/8"
(3,2 mm)
J
MOUNTING
SURFACE
1
CLOSURE SERIES 1-1/4" (31,8 mm)
TY-FRB 1" (25,4 mm)
FIGURE 9
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
4.2 K-FACTOR, 1/2 IN. NPT
0
TFPI7I
Page 6 of 10
2-7/8' DIA.
- 5/8±1/4' (73,0 mm) 3/4" (19,1 mm)
(15,9±6,4 mm) 2-1/4' DIA. 1/4 (6,4 mm)
/ FACE OF •:: (57,2 mm) MOUNTING
__ _______
-'/r__ PLATE I SPRINKLER
FITTING
1/8
_ -I
___ _____
(3,2 mm)
MOUNTING / 4
SURFAC7 SERIES
1-1/4' (31,8 mm) CLOSURE TY-FRB 3/4" (19,1 mm)
FIGURE 10
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 10 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 IN. NPT
2-7/8" DIA.
(73,0 mm) 3/4" (19,1 mm) 5/8±1/4'
(15,9±6,4 mm) 2-1/4" DIA. -
1/4" (6,4 mm)
/ (57,2 mm) FACE OF MOUNTING
SPRINKLER I PLATE I
FITTING
- _____ __ _____ (3,2 mm)
4
-/:_1/8"
MOUNTING /'
SURFAC>//
CLOSURE SERIES 1-5/16" (33,3 mm)I
TYFRB 13/16" (20,6 mm)
FIGURE 12
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT
STYLE 40 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 IN. NPT -
WRENCH RECESS
(END "A" USED FOR
1/2" NPT MODELS)
WRENCH RECESS
(END "E" USED FOR
3/4" NPT MODELS)
FIGURE 14
W-TYPE 6 SPRINKLER
WRENCH
2-7/8" DIA.
-. (73,0 mm) 1/2±1/8" 11/2" (12,7 mm)
(12,7±3,2 mm) 2-1/4" DIA. 1/4' (6,4 mm) I
FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE I I FITTING
1/8"
(3,2 mm) I
_-
MOUNTING
SURFACE 7
SERIES 1-1/4'(31,8 mm) 1 CLOSURE TY-FRB 1" (25,4 mm)
FIGURE 11
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 20 RECESSED ESCUTCHEON
5.6 K-FACTOR, 1/2 IN. NPT
2-7/8" DIA.
1/2±1/8" (73,0 mm) 1/2" (12,7 mm)
(12,7±3,2 mm) - 2-1/4" DIA 1/4" (6,4 mm)
/ FACE OF (57,2 mm) MOUNTING
SPRINKLER PLATE
FITTING
1/8"
T_ \
MOUNTING
SURFACE
CLOSURE SERIES 1-5/16" (33,3 mm)
TYFRB 1-1/16" (27,0 mm)
FIGURE 13
SERIES TY-FRB RECESSED PENDENT
WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT
STYLE 30 RECESSED ESCUTCHEON
8.0 K-FACTOR, 3/4 IN. NPT
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 15
W-TYPE 7 RECESSED
SPRINKLER WRENCH
TFPI7I
Page 7 of 10
Sprinkler Finish5
K- Type Type Temperature Bulb Liquid
Color
Natural
Brass Chrome Plated Polyester
2.8
1/2 in. NPT
Pendent
(TY1231)
and
Upright
(TY1131)
135°F (57°C) Orange
1, 2, 3, 4
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
Recessed
Pendent
(TY1231)a
Figure 6
135°F (57°C) Orange
1,2,4
155°F (68°C) Red
175°F (79°C) Yellow
200°F(93°C) Green
Recessed
Pendent (TY1231)b
Figure 7
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
4.2
1/2 in. NPT
Pendent
(TY2231)
and
Upright
(TY2131)
135°F (57°C) Orange
1,2
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
286°F (141°C) Blue
Recessed
Pendent (TY2231)a
Figure 8
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
Recessed
Pendent
(TY2231)b
Figure 9
135°F (57°C) Orange
155°F (68°C) Red
175° F (79°C) Yellow
200°F(93°C) Green
NOTES
Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable.
Installed with Style 20(1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable.
Frame and Deflector only.
Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the City of New York under MEA 354-01-E.
Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion-
resistant sprinklers.
TABLE A
LABORATORY LISTINGS AND APPROVALS FOR
2.8 AND 4.2 K-FACTOR SPRINKLERS
S
TFPI7I
Page 8 of 10
Sprinkler Finish8
K-
Factor Type Temperature Bulb Liquid
Color
Natural
Brass
Chrome
Plated Polyesterc Poly.Stainlessc Lead
Coated
Pendent
(TY3231)
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow and 1, 2, 3, 4, 5, 6, 7 1,2 1,2,3,5
Upright
(TY3131)
Blue
200°F (93°C) Green
286-F (141-C)
135°F (57°C) Orange
155°F (68°C) Red 5.6
1/n
NPT
Recessed
Pendent
(TY3231)a
Figure 10
1, 2, 4, 5 1,2 N/Ad 175°F (79°C) Yellow
200°F (93°C) Green
286°F(141°C) Blue
135°F (57°C) Orange
155°F (68°C) Red Recessed
Pendent (TY3231)b 1,2,3,4,5 N/A N/A 175°F (79°C) Yellow
200°F (93°C) Green Figure 11
286°F (141°C) Blue
Pendent
(TY4231)
135°F (57°C) Orange
155°F (68°C) Red
175°F(79°C) Yellow and 1, 2, 3, 4, 5, 6, 7 1,2 1,2,5
Upright
(TY4131) Blue
200°F (93°C) Green
286°F(141°C)
135°F (57°C) Orange
155°F (68°C) Red 8.0
3/4 in
NPT
Recessed
Pendent (TY4231)a
Figure 12
1, 2, 5 1,2 N/A 175°F (79°C) Yellow
200°F (93°C) Green
286-F (141-C) Blue
135°F (57°C) Orange
155°F (68°C) Red Recessed
Pendent
(TY4231)b
Figure 13
1, 2, 3, 5 N/A N/A 175°F (79°C) Yellow
200°F (93°C) Green
286°F(141°C) Blue
8.0
Pendent
(TY4931)
135°F (57°C) Orange
155°F (68°C) Red
175°F (79°C) Yellow 1/2 in. and 1, 2, 4, 5, 6 N/A 1, 2, 5
NPT Upright
(TY4831) Blue
200°F (93°C) Green
286-F (141-C)
NOTES
Installed with Style 10 (1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable.
Installed with Style 20 (1/2 in. NPT( or Style 30 (3/4 in. NPT( 1/2 in. Total Adjustment Recessed Escutcheon, as applicable.
Frame and Deflector only.
Not Available (N/A)
Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL( as Quick Response Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed
sprinklers.
Approved by the City of New York under MEA 354-01-E.
VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Faa 31-53-428-3377.)
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers.
Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where
Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers.
TABLE B
LABORATORY LISTINGS AND APPROVALS FOR
5.6 AND 8.0 K-FACTOR SPRINKLERS
0
TFPI7I
Page 9 of 10
Sprinkler Finish
K-
Factor Type Natural
Brass
I Chrome
Plated
I Polyester Lead Coated
Pendent (TY1231)
and 2.8 upright (TY1131) 1/2 in. 175 psi (12,1 bar) N/A2
NPT Recessed
Pendent (1Y1231)
Pendent (1Y2231)
and
4.2 Upright (TY2131)
1/2 in. 175 psi (12,1 bar) N/A
NPT Recessed
Pendent (TY2231)
Pendent (TY3231)
and 5.6 Upright (TY3131) 250 psi (17,2 bar)
1/2 in. or 175 psi (12,1 bar)'
NPT Recessed
Pendent (TY3231)
Pendent (TY4231) 175 psi
8.0
and
upright (TY4131) (12,1 bar)
3/4 in. 175 psi (12,1 bar)
NPT Recessed N/A Pendent(TY4231)
8.0 Pendent (TY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831)
NOTES
The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. UL); the Listing by Under-
writers Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York.
Not applicable (N/A).
Care and
Maintenance
The TYCO Series TY-FRB 2.8, 4.2, 5.6,
and 8.0 K-factor Upright, Pendent, and
Recessed Pendent Sprinklers must be
maintained and serviced in accordance
with this section. Before closing a fire
protection system main control valve
for maintenance work on the fire pro-
tection system that it controls, obtain
permission to shut down the affected
fire protection systems from the proper
authorities and notify all personnel who
may be affected by this action.
Absence of the outer piece of an
escutcheon, which is used to cover
a clearance hole, can delay sprinkler
operation in a fire situation.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
TABLE C
MAXIMUM WORKING PRESSURE
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be taken to avoid damage
to the sprinklers before, during, and
after installation. Sprinklers damaged
by dropping, striking, wrench twist/
slippage, or the like, must be replaced.
Also, replace any sprinkler that has a
cracked bulb or that has lost liquid from
its bulb. (Ref. Installation Section).
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the National Fire Protection Asso-
ciation (e.g., NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or sprinkler manufac-
turer regarding any questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb. (Ref. Installa-
tion Section).
Initial and frequent visual inspections of
random samples are recommended for
corrosion-resistant sprinklers to verify
the integrity of the corrosion-resistant
material of construction. Thereafter,
annual inspections per NFPA 25 should
suffice.Inspections of corrosion-resis-
tant sprinklers are recommended at
close range, instead of from the floor
level per NFPA. Inspection at close
range can better determine the exact
sprinkler condition and the long-term
integrity of the corrosion-resistant
material, which can be affected by the
corrosive conditions present.
FINISH
1 NATURAL BRASS
- POLY-STAINLESS GREY
2 ALUMINUM (RAL9007)1
-
POLYESTER
PURE WHITE
-
POLYESTER (RAL9010)2
SIGNAL WHITE
-
POLYESTER (RAL9003)
JET BLACK
-
POLYESTER (RAL9005)3
7 LEAD COATED
9 I CHROME PLATED
TFPI7I
Page 10 of 10
P/N 57- XXX- X- XXX
I I
SIN SPRINKLER
330 2.8K UPRIGHT (1/2 in. NPT) TY1131
331 2.8K PENDENT (1/2 in. NPT) TY1231
340 4.2K UPRIGHT (1/2 in. NPT) TY2131
341 4.2K PENDENT (1/2 in. NPT) TY2231
370 5.6K UPRIGHT (1/2 in. NPT) TY3131
371 5.6K PENDENT (1/2 in. NPT) TY3231
390 8.0K UPRIGHT (3/4 in. NPT) TY4131
391 8.0K PENDENT (3/4 in. NPT) TY4231
360 8.0K UPRIGHT (1/2 in. NPT) TY4831
361 8.0K PENDENT (1/2 in. NPT) TY4931
TEMPERATURE
RATINGS
I 135
155 I 155°F(68°C)
175 1 175-F (79-C)
200 1 200°F (93°C)
286 1 286°F (141°C)
NOTES
Available only on TY3131, TY3231, TY4131, and TY4231
Eastern Hemisphere sales only.
Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires longer lead time
to manufacture.
TABLED
SERIES TV-FRB PENDENT AND UPRIGHT SPRINKLERS
PART NUMBER SELECTION
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for
availability. When placing an order,
indicate the full product name and Part
Number (P/N).
Sprinkler Assemblies with NPT
Thread Connections
Specify: Series TY-FRB (Specify SIN),
(specify K-factor), (specify Pendent or
Upright) Sprinkler (specify) temperature
rating, (specify) finish or coating, P/N
(specify from Table D)
Recessed Escutcheon
Specify: Style (10, 20, 30, or 40)
Recessed Escutcheon with (specify*)
finish, P/N (specify*)
Refer to Technical Data Sheet TFP770
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
C
1400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +11-2115-362-0700 ,jj P
02018 Johnson Controls. All right, rnaePand. All aponifisaliona and othor information shown waro oarrnnl an of document ronisiRn dab and are oablnst In change without notion. Johnson '1' +('
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered ,tOdemgrhs of National Fire Protection ASsonlorlon;
TEFLON Is a registered tr005rnanl, Of DuPont Controls
Jt WheatlandTube
JMC STEEL GROUP
700 South Dock Street
Wheatland, PA 16146
800.257.8182 40
www.wheatland.com
Wheatland ASTM A 53
Schedule 40 and Schedule 80 Pipe
Wheatland Steel Pipe is made by specialists who understand that it's the small details
that make the difference between average products and superior products. At the Wheatland Plant,
most department heads and foremen have been employed in some phase of pipe manufacturing
for 25 or more years.
This kind of specialization, experience and knowledge pays off.. .in workable, threadable,
uniform pipe. Delivered clean. Delivered promptly.
Wheatland specializes in manufacturing welded steel pipe in 1/2 through 4 nominal sizes.
Available inventory in 1/8 to 12 pipe sizes produced to various ASTM standards is maintained to
meet your pipe requirements.
Care, pride and personal concern are bonus features that go into every inch of Wheatland
Pipe. Don't settle for less.
Make sure it's quality. Make sure it's Wheatland.
Standard Pipe Schedule 40 ASTM A 53 Grades A and B
Outside
Diameter
Inside
Diameter
Wall
Thickness Nominal Weight (Mass) per unit Length
NPS
Designato
DN
(Inches) (mm) Designator Plain (Inches) (mm) (Inches) (mm) End
(lb/if)
Plain End
(kg/rn)
Threads & Threads &
Couplings Couplings
(Ib/ft) (kg/m
1/8 6 0.405 10.3 0.269 6.8 0.068 1.73 0.24 0.37 0.25 0.37
1/4 8 0.540 13.7 0.364 9.2 0.088 2.24 0.43 0.63 0.43 0.63
3/8 10 0.675 17.1 0.493 12.5 0.091 2.31 0.57 0.84 0.57 0.84
1/2 15 0.840 21.3 0.622 15.8 0.109 2.77 0.85 1.27 0.86 1.27
3/4 20 1.050 26.7 0.824 20.9 0.113 2.87 1.13 1.69 1.14 1.69
1 25 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.50 1.69 2.50
1-1/4 32 1.660 42.2 1.380 35.1 0.140 3.56 2.27 3.39 2.28 3.40
1-1/2 40 1.900 48.3 1.610 40.9 0.145 3.68 2.72 4.05 2.74 4.04
2 50 2.375 60.3 2.067 52.5 0.154 13.91 3.66 5.44 3.68 5.46
2-1/2 65 2.875 73.0 2.469 62.7 0.203 5.16 5.80 8.63 5.85 8.67
3 80 3.500 88.9 3.068 77.9 0.216 5.49 7.58 11.29 7.68 11.35
3-1/2 90 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.57 9.27 13.71
4 100 4.500 114.3 4.026 102.3 0.237 6.02 10.80 16.07 10.92 16.23
5 125 5.563 141.3 5.047 158.2 0.258 6.55 14.63 21.77 14.90 22.07
6 150 6.625 168.3 6.065 154.1 0.280 7.11 18.99 1 28.26 1 19.34 28.58
8 200 8.625 219.1 7.981 202.7 0.322 8.18 28.58 42.55 29.35 43.73
10 250 10.750 273.0 10.020 254.5 0.365 9.27 40.52 60.29 41.49 63.36
Standard Pipe
121 1 300 12.750 323.8 12.000 1 304.8 1 0.375 1 9.52 49.61 73.78 51.28 76.21
Note' NPS 12 dimensions are for standard wall pipe, not schedule 40.
ProductType and Specification:
Standard welded pipe is produced in 1/2 to 6 trade sizes. Wheatland pipe is produced to ASTM A 53
Grades A and B, A 501, and A 589 Type II, API 5L and Federal Specification WW-P404. All pipe
threads conform to ANSI 131.20.1. Merchant couplings comply with ASTM A 865.
Specifications and descriptions are accurate as known at time of publication and subject to change
without notice.
'1ID 11111IRON eI'IDEG. ELBOW
I NOMINAL
SIZE
(INCH)
I ITEM
CODE
I MAX.
WORKING
P.S.I.
IDIM ENSIONSI WEIGHT I
A B
EACH
PIECE
I DB90033 500 1.50 1.50 0.62
1114 DB90044 500 1.75 1.75 0.90
1112 1 DB900551 500 1 1.94 1.94 1 1.20
2 1 DB900661 500 1 2.25 1 2.25 1 1.85
I DUCTILE I RONI 1 illilDEG. E LBOWj
NOMINAL
SIZE
(INCH)
ITEM
CODE
MAX.
WORKING
P.S.I.
DIMENSIONS WEIGHT
-
A
-
B
EACH
PIECE
1X1/2 DB90031 500 1.26 1.36 0.44
1X3/4 I DB90032 500 1.37 1.45 0.52
I 1/4X1/2 DB90041 500 1.34 1.53 0.64
I 1/4X3/4 DB90042 500 1.45 1.62 0.72
I 1/4X1 DB90043 500 1.58 1.67 0.75
I 1/2X1 DB90053 500 1.65 1.80 0.92
I 1/2X1 1/4 DB90054 500 1.82 1.88 1.08
2X112 DB90061 500 1.49 1 1.88 1.08
2X3/4 DB90062 500 1.60 1.97 1.24
2X1 DB90063 500 1.73 2.02 1.40
2X11/4 DB90064 500 1.90 2.10 .52
2X11/2- DB90065 500 2.02 2.16 1.65
DUCTILE IRON COUPLING
NOMINAL
SIZE
(INCH)
ITEM
CODE
#
' MAX.
WORKING
P.S.I.
IDIMENSb0i WEIGHT
EACH
PIECE A
I DCL033 500 1.67 0.40
11/4 0CL044 500 1.93 0.57
11/2 DCLO55 1 500 1 2.15 0.75
2 DCL066 1 500 1 2.53 1.15
DUCTILE IRON 45 DEG. ELBOW
NOMINAL
SIZE
(INCH)
I ITEM
CODE
#
' MAX.
WORKING
P.S.I.
'DIMENSIONS I WEIGHT I
A B
EACH
PIECE
I DB45033 500 1.12 1.12 0.46
11/4 DB45044 500 1.29 1.29 0.73
11/2 DB45055 500 1.43 1.43 0.92
2 1 DB450661 500 1.68 1.68 1.50
DUCTILE IRON STRAIGHT ccl:.TEE
NOMINAL
SIZE
(INCH)
ITEM
CODE
#
' MAX.
WORKING
P.S.I.
'DIMENSIONS WEIGHT'
-
A B
EACH
PIECE
I DT333 500 1.50 1.50 0.85
11/4 DT444 500 1.75 1.75 1.22
11/2 DT555 500 1.94 1.94 1.55
2 DT666 500 2.25 2.25 2.45
I DUCTILE IRON!RED. COU I [c
NOMINAL
SIZE
(INCH)
ITEM
CODE
#
MAX.
WORKING
P.S.I.
DIMENSION WEIGHT
EACH
PIECE A
IXI/2 DRC03I 500 1.69 0.39
1X3/4 DRC032 500 1.69 0.53
C
D.I. THREADED FITTINGS
LISTED LISTED APPROVED
For fire protection services request submittal GRS 1.3
Ductile iron threaded fittings are UL, ULC listed and factory mutual approved for 500 psi
service. Ductile iron per ASTM A 536 grade 65-45-12. Dimensions conform to ANSI 1316.3
y class 150. Threads are NPT per ANSI/ASME B1.20.1.
13 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore,
over tightening can cause damage to pipe threads which may cause leakage. Ductile iron
fittingd should be tightened theree turns beyond hand tight, but no more than four turns.
STAR ®PIPEPRODUCTS
Page 21
El. SHE) Iewqns jsenbei S8OIM9S uo!pejojd eij joj
G3A0JddY aaLsn aasn
<*> : oqq IV
SDNII.LEI aav3IH1 Ta
S13[1UOmcfk1IJ®WV1S
Nor, 1~ off T774 m
'4W1H711
1jul4
I'4Illu
;zI 1 i.i i;ir
'XVW ki.II.I
21 9NI3fl0èI NOM 31113na
Oi. WI. 009 toxa
9P I. 091. 991. 009 csoxa i.xn. 1.
LII. L9 991. 009 tPDX0 I.XP/L I.
96 009 990X0
061. V61 P61. 009 ssoxa iii. 1.
091. SL SVI. 009 PPDXO I P/I. I.
960 091 091. 009 CCOXO I.
333Id
HOV3
9 V
-
ISd
9NI)I0M
'XVW
#
3003
Mil
(HONI)
3Z1S
1VNIVl0N I .LH9M ISN0ISN3VJI0
SSONOINONIF I! kill'
e
I.60 SP I. 009 900d30
090 Cc' I. 009 900d30 III. I.
£PO 9I. 009 P00d30 P/I. I.
CO 91.1. 009 £00d30 1.
3331d
H3V3
I J9M
V iSd
_______ ONDIdOM
IN0ISIBINI0I 'XVW
#
3003
I IlB1I
(HONI)
3ZIS
1VNILN0N
dVO [iI I F II kill'
I.9'O mO orz PE0 890 S9HSfl90 in IX
L0 IflO arz P50 99*0 P9HSfl90 in I.X
99'0 NI 961. 1.P0 980 £9HSfl90 I.X
050 .Lfl0 00 1.50 590 PSHSfl90 P/I. 1.X/I I.
PP•0 mO 00 1.50 CWO E9HSfl90 I.X/I. I.
90 mO 9L1. I 9Z0 080 £PHSfl90 1.XP/I. I.
LI.0 .Lfl0 zv1. 90 SL0 ZCHsnea P/CXI.
.Lfl0 in S0 9L0 I.EHSflBO zan
H3V3 31A.LS 3 9 V
30o3
Vi31I
(H3NI)
MIS
1VNILØI0N SN0ISN3VII0
]II:lI:u sIIFI PkIIIu
V3H 3GISNI avH aismno
i 2
SAMMYS® FOR WOOD
No pre-drilling required.
Quick to install using the Sammy
Nut Driver with an 18V cordless
drill/driver.
Saves time from traditional
methods.
Reduces installation costs.
Manufactured in the U.S.A.
Wa
a udeo demonst,atica atl www.itwbuildex.comJ
i -
#14 Black
Nut Driver
Part # 8113910
i .
#14 SW Red
Nut Driver
Parl# 8114910
1/4" 8002957 GST 100 1/4 xl 210 (7/16OSB) 25 125
[ 1/4" 8003957 GST 200' 1/4x2" - 1760 (Fir) - 25 125
3/6" 8007957 GST 10 1/4 x1" 210 (7/16"OSB) 300 25 125
3/8" 8008957 GST2O 114x2" 1760 (Fir) 850 1475 25 125
8068925 GST 2G-SS 1/4x2" 1760 (Fir) 850 25 - 125 - -
— 3/88009925 GST 25-380 3/8x21/2" 2113 (Fe) 1500 25 125
3/6" 8010957 GST 30 1/4x3" 2060 (Fir) - - 1500 1475 25 125
1 3/8 - 8069925 GST 30-SS 1/4 x 3 2060 (Fe) - - 25 125
1/2" 8013925 GST 2 1/4 x 2 1760 (Fir) 25 - 125
r - 1/2 8015925 GST 3 1/4 x3 2275 (Fir) 25 125
M"JUUFACTURED = 17 Qil USA
SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into
contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.
NAW f~w%~MYS
Not less than 2' nominal width
(1-1/2") up to 3-1/2" pipe; not .ess than
3" (2-1/2') nominal width 4" & 5" pipe
Minimum 2-1/2" from bottom for
branch lines. Minimum 3" from bot-
tom for main lines. Exception: This
requirement shall not apply to 2" or
thicker nailing strips resting on top of
1
f
steel beams.
_________________ No pre-drilling required.
"Quick to install using the Sammy
Floor Joist Nut Driver with an 18V cordless
drill/driver
Saves time from traditional
methods.
'
Reduces installation costs.
Manufactured in the U.S.A.
Wsta ,deo dam Oar at) www.ilwbuildex.comJ
o
8319957
-3 .8.320957 a 3/8' - 8021957
ll
114
I ...." 873925
- 3/8" 8022925
#14 SW Red [ - 3/6" 8023925
Nut Driver
Pert #8114910 * May require pre-drilling; consutt joist manufacturer
SWG 200 1/4x2 1725 (Fir) 25 125
- SWG 10 1/4x1" 622 (Fir) 300 25 - 125
SWG 20 1/4 x 2' 1725 (Fir) 1050 25 125
SWG 20-SS 1/4x 2" 1725 (Fir) 850 25 125
SWG 25-380 - 3/8x2-112" 2249 (Fir) - 1500 25 125
- SWG 30 114x3" 1884 (Fir) - 25 - 125
Eliminates distortion of threaded rod.
Accommodates up to 3 W x 12 pitch roof.
"Allows 17" deflection from vertical.
Saves time from traditional methods.
Reduces installation costs.
"Manufactured in the U.S.A.
Black cWIY14U2[.1IJi
NutDriver -
-
3/8" 8139957 SH-GST2O 114x2"
-
1257 (Fir) Part#8113910 1903 Dim. Lumber Q. 3/ 8269957 SH-GST/CST 20 5/16x 1-3/4" 1406 @ 45off vertical
Dim. Lumber
903 Dim. Lumber
1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45"olf vertical
Dim. Lumber
* May require pre-drilling; consult joist manufacturer.
#14 SH Orange
Nut Driver
Pert # 8273910
1500
850 @45" 25 125
25 125
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
38 Fire Protection Solutions B-Line
by E1.N
Pipe Clamps
S Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe**
Double Fastener Strap Side Mounted (B-Line B3183)
Size Range: 3/4" (20mm) thru 2 (50mm) CPVC pipe
Material: Pre-Galvanized Steel
Function: Intended to perform as a hanger to support CPVC piping used in
automatic fire sprinkler systems. Can be installed on the top or on the bottom
of a beam.
Approvals: Underwriters Laboratories Listed in the USA (UL) and
Canada (cUI) to support fire sprinkler piping. May be installed in wood using
fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel
using (2) 1/4" 3< 1" tek type screws. Meets and exceeds the requirements of
NFPA 13, 13R and 13D.
Features: Fig. 24 incorporates features which protect the pipe and
ease installation. The flared edge design protects the CPVC pipe from
any rough surface. Easily attaches to the building structure using the
two UL Listed hex head self threading screws* furnished with the I )
product. It is recommended that rechargeable electric drills fitted with
a hex socket attachment be used as installation tools. No impact I j
tools (such as a hammer) are allowed. Damage has been known to
result from installations using impact type tools. No pre-drilling of a
I./
pilot hole in wood is required. V
Finish: Pre-Galvanized ,
Order By: Figure number and pipe size
* Hardened hex head self threading screw is furnished with the -
product and is the minimum fastener size acceptable.
** With reduced spacing, consult factory.
OTQLCO
Ic @us
LISTED
CPVC Max. Hanger Fastener Hex Approx. S Pipe Size A B C Spacing Head Size Wt./100
Part No. in. 1mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg)
24-/4 3/4' (20) 2/16' (58.7) 1/32' 127.81 1/16' (30.2) 51/3 (1.67) /it' (7.9) 9 (4.1)
24-1 1' (25) 2/8' (66.7) 1/16' (33.3) 1/16' (30.2) 6 (1.83) /16' (7.9) 9 (4.1)
24_11/4 11/4 (32) 3" (76.2) 11/2 138.11 1/16" (30.21 61/2 (1.98) /16' (7.9) 11 (5.0)
24-11I2 11/2 (40) 31/4 182.51 1/8" 142.31 1/16' (30.2) 1 (2.13) /16" (7.9) 12 (5.4)
24-2 2' (50) 311/16' (93.7) 127/32' (43.6) 1/16' (30.2) 8 (2.44) /16" (7.9) 15 (6.8)
Fig. 25 - Surge Restrainer C
@
r Size Range: - One size fits 3/4 (20mm) thru 2 (40mm) pipe. LISTED
Material: - Pre-Galvanized Steel
Function: - Designed to be used in conjunction with Fig. 200 band
::.........
.• / -
hangers
to restrict the upward movement of piping as it occurs during sprinkler
head activation or earthquake type activity. The surge restrainer is
easily and efficiently installed by snapping into a locking position on the
band hanger. This product is intended to satisfy the requirements as
indicated in the National Fire Protection Association NFPA 13 2010
edition 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel
pipe or CPVC plastic Pipe
Approvals: - Underwriters Laboratories Listed only when used with
band hanger Fig. 200, in the USA (UL) and Canada (cUI).
Finish: Pre-Galvanized
Order By: Figure number and band hanger, size from S 3/4" (20mm) thru 2" (40mm).
Patent #5,344,108
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
94 Fire Protection Solutions B-Line
by Ei.N
Threaded Accessories
B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) ®TOL. CCY
B32051 - Threaded Rod (right & left hand threads) 0
Size Range: 3/8"-1 6 thru 3°-4 rod
Material: Steel
TL
Function: Recommended for use as a hanger support in hanger assemblies. Specify Length
Rod is threaded on both ends with right hand threads of the length shown. Also
available with left and right hand threads - specify Fig. B3205L when ordering.
Maximum Temperature: 750°F (399°C) TL
Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and
materials. Thread Size
Order By: Figure number, rod size, length and finish
Standard Design Load
Thread Size Thread Length TI 650°F (343°C) 750°F (399°C)
Part No. A in. (mm) Lbs. (kN) Lbs. (kN)
B3205-/ x V 318"-16 21/2" (63.5) 130 (3.25) 572 (2.54)
B3205-1/2 X 'L 1/2°_13 21/2 (63.5) 1350 (6.00) 1051 (4.70)
B3205-518x 'L /8"-11 21/2" (63.5) 2160 (9.61) 1692 17.521
B3205-3/4 x /4"-10 3° (76.2) 3230 (14.37) 2530 (11.25)
B3205-1/8 x /811-9 31/2" (88.9) 4480 (19.93) 3508 (15.60)
For larger sizes consult full line pipe hanger catalog.
ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100)
Size Range: /"-16 thru 11!2'6 rod in 10' (3.05m) lengths
Material: Steel
Maximum Temperature: 750°F (399°C)
Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials.
Order By: Figure number, rod size, length and finish
Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length.
Part No. Threads Recommended Load Approx. Wt.I100 Ft.
& Size Per Inch Lbs. (kN) Lbs. (kg)
AIR 1/4" x '1' 20 240 (1.07) 12 (5.44)
ATR /8" x'1' 16 730 13.241 29 (13.15)
ATR 1/2" x'1' 13 1350 (6.00) 53 (24.04)
ATR 5/g" x'1' 11 2160 (9.60) 89 (40.37)
ATR 3/4" x'1' 10 3230 (14.37) 123 (55.79)
ATR hg" x '1' 9 4480 (19.93) - 170 177.111
For larger sizes consult full line pipe hanger catalog.
RM
Fig. 200-1/2. 200-/4
Fig. 20021I2 to 200-8
Fig. 200
Fig. 200S
Pipe Hangers
®TOLCO'
c@ us
LISTED . Fig. 200 - 'Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF)
Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF)
Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC)
Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut
Size Range:
Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe
Material: Steel, Pre-Galvanized to G90 specifications
Function: For fire sprinkler and other general piping purposes. Knurled
swivel nut design permits hanger adjustment after installation.
Features:
11/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe
types and protect CPVC plastic pipe from abrasion. Captured design - -
keeps adjusting nut from separating with hanger. Hanger is easily
installed around pipe.
For hanger with non-captured nut order Fig. 200S.
(21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in
hanger before installation. Adjusting nut is easily removed.
Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm))
in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and
Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2
Conforms to Federal Specifications \MN-H-171 F & A-A-1 192A, Type 10
and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58,
Type 10.
Maximum Temperature: 650°F (343
be supplied with (2) hex
°c)
Finish: Pre-Galvanized. Stainless Steel -.
materials
in '
t5
l
er By: Figure 1 and pipe T
Designed to meet or exceed requirements of
Fig. 200C Fig. 200F
Pipe Size Rod Size A B Approx. Wt./100
Part No. in. (mm) in. (mm) in. (mm) lbs. (kg)
200-1/2 1/2" (15) /8"-16 31/8" (79.4) 2/8" (66.7) 11 (5.0)
200-3/4 3/4" (20) /8"-16 31/8" (79.4) 21/2' (63.5) 11 (5.0)
200-1 1" (25) /8"-16 3/8" (85.7) 2/8' (66.7) 12 (5.5)
200_11/4 11/4" (32) /8"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9)
200-11/2 11/2" (40) /8'-16 3/e' (98.4) 2/8" (73.0) 14 (6.4)
200-2 2" (50) /8"-16 41/2" (114.3) 3' (76.3) 15 (6.9)
200-21I2 21/2" (65) /e"-16 5/8" (142.9) 41/8" (104.7) 27 (12.3)
200-3 3' (75) /8"-16 5/8' (149.1) 4" (101.6) 29 113.31
200-31I2 31/2" (901 /8"-16 1/8" (187.3) 51/4" (133.3) 34 (15.6)
200-4 4" (100) /8"-16 7/8" (187.3) 5" (127.0) 35 (16.0)
200-5 (125) 1/2"..13 91/8" (231.8) 61/4" (158.7) 66 (30.2)
200-6 (150) 1/2 .13 101/8" (257.2) 6/4" 1171.41 73 133.41
200-8 8" (200) 1/2 .13 131/8" (333.4) 8/4" (222.2) 136 162.31
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Fire Protection Solutions 21 by Ei.N