HomeMy WebLinkAbout2728 LOKER AVE W; ; FPC2020-0123; Permitccityof PERMIT REPORT Carlsbad Print Date: 12/02/2020 Permit No: FPC2020-0123 Job Address: 2728 LOKER AVE W, CARLSBAD, CA 92010-6603 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2090812900 Track #: Applied: 07/17/2020 Valuation: $24,787.76 Lot #: Issued: 07/28/2020 Occupancy Group: Project #: Finaled Close Out: 07/29/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Inspector: Plan Check #: Final Inspection: Project Title: Description: COPAN DIAGNOSTICS -SPRINKLER TI (2 HEADS) FPContractor: COSCO FIRE PROTECTION INC 1075 W LAMBERT RD BREA, CA 92821-2944 (858) 444-2000 FEE AMOUNT FIRE NFPA 13 or 13R System 6 heads or less $125.00 Total Fees: $125.00 Total Payments To Date: $125.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov f:rc 20 O •" I cosco .1S..II. 00 . I. I'• Fire Protection San Diego Branch Office 4990 Greencraig Lane San Diego, CA 92123 (858) 444-2000 fax: 444-2056 CA Lic.: C-16 #577621 www.coscofire.com MATERIAL SUBMITTAL Date: 7-13-20 COPAN DIAGNOSTICS 2728 LOKER AVE. WEST CARLSBAD, CA. All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: FELIPE A. Los Angeles • San Francisco • Orange 0 Fresno • San Diego • Seattle a-i o tqca® Worldwide www.tyco-fire.com Contacts I Series TYFRB - 2.8,42,5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described in herein are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers. They are designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. The TY-FRB Recessed Pendent Sprin- kler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following Recessed Escutcheons: A two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. A two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 to corrosive atmospheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, con- centration of chemicals, and gas/ chemical velocity, should be consid- ered, as a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356. Sprinkler Guards are detailed in Technical Data Sheet TFP780. NOTICE The Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. JULY 2018 Sprinkler Identification Number (SIN) TY1131 ... Upright 2.8K, 1/2 in. NPT TY1231.. Pendent 2.8K, 1/2 in. NPT TY2131 . . . Upright 4.2K, 1/2 in. NPT TY2231.. Pendent 4.2K, 1/2 in. NPT TY3131 . . . Upright 5.6K, 1/2 in. NPT TY3231.. Pendent 5.6K, 1/2 in. NPT TY4131 . . . Upright 8.0K, 3/4 in. NPT TY4231.. Pendent 8.0K, 3/4 in. NPT TY4831 ... Upright 8.0K, 1/2 in. NPT TY4931.. Pendent 8.0K, 1/2 in. NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion-resistant status. Maximum Working Pressure Refer to Table C TFPI7I C TFPI7I Page 2 of 10 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing ** Pipe thread connections per ISO 7-1 can be provided on ESCUTCHEON special request. PLATE SEATING SURFACE RX __________________________________ 1 2-1/4 (57,2 mm) v 2-3/16 (55,6 mm) 1 1-9/16 (39,7 mm) 1/2 NPT** t WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON * Temperature rating is indicated on Deflector. 7/16 (11,1 mm) NOMINAL MAKE-IN CROSS SECTION 2-7/8 (73,0 mm) DIA. RECESSED PENDENT FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TV1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING SURFACE 1 7/16 NOMIN MAKE-IN AL (55,6 mm) 2-3/16 1-1/2 (11,1 mm) 2-3/1 6 (38,1 mm) (55,6 mm) . 1/2 NPT** f WRENCH STYLE 100r20 FLATS RECESSED 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* F- 2-7/8 (73,0 mm) DIA. -H UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 IN. NPT S Discharge Coefficient K=2.8 GPM/psi½ (40,3 LPM/bar½) K=4.2 GPM/p5i½ (60,5 LPM/barY) K=5.6 GPM/psi' (80,6 LPM/bar") K=8.0 GPM/psi/2 (115,2 LPM/bar½) Temperature Rating Refer to Table A and B Finishes Sprinkler: Refer to Table D Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb ...............................Glass Compression Screw .................Bronze Deflector ...................Copper/Bronze Bushing (K=2.8) ....................Bronze Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel* Bulb ...............................Glass Compression Screw .....L316 Stainless Steel* Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON Type L316 stainless steel (IJNS 31603) per ASTM A479/479M or BOON 1008 WN1.4404. Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, for recessed pendent installations. * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. 2-7/8' (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 3 of 10 ESCUTCHEON PLATE SEATING SURFACE I 7/16" NOMINAL 2-MAKE-IN (11,1 mm) (55,6mm) 2-3/16' (55,6 mm) 1/2' NPT** I WRENCH STYLE 10or20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression S 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. JJN(OMINAL 7/16' 1,1 mm) 2-3/16" _F AKE-IN (55,6 mm) /2"2-3/16'____ (55,6 mm) mm) I (38,1 STYLE 10 RECESSED UPRIGHT PENDENT ESCUTCHEON ril C: 4 f6 = RECESSED PENDENT POLY-STAINLESS FINISH ONLY FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT Installation The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 lb-ft (13,4 to 26,8 N.m). Higher levels of torque can distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to com- pensate for insufficient adjustment in the escutcheon plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1 to Figure 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1 t 4, apply the W-Type 7 Recessed Sprin- kler Wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Recessed Pendent Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. C UPRIGHT PENDENT STYLE 40 RECESSED ESCUTCHEON 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION 2-7/8 (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION TFPI7I Page 4 of 10 1 - Frame 3 - Sealing 5 - Compression ESCUTCHEON 2 - Button Assembly Screw PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2 (12,7 mm) NOMINAL I _ MAKE-IN 2-1/4 T(57 m 51/11 m) 1-9/16 (57,2 mm) (39,7 mm) - 3/4 NPT' f WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated SURFACE 4 - Bulb 6 - Deflector* on Deflector. POLY-STAINLESS FINISH ONLY FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT S * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector, special request. CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 3 - Sealing 6 - Deflector * Assembly 4 - Bulb 2-1/4 (57,2 mm) * Temperature rating is 1-9/16 indicated on Deflector. (39,7 mm) ** Pipe thread connections per ISO7-1 can be * 6 provided on special request. CROSS SECTION \ 7/16 I (111 , mm) I NOMINAL Ll MAKE-IN I I I V 3/16" (55,6 mm , 1/2 NPT** I WRENCH FLATS UPRIGHT PENDENT FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 IN. NPT 0 TFPI7I Page 5 of 10 S 2-7/8 DIA. 5/8±1/4' (73,0 mm) I 3/4" (19,1 mm) (15,9±6,4 mm) I 1/4' (6,4 mm) / FACE OF 2-1/4' DIA. (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) r - ra~ MOUNTING / SURFACE,/" CLOSURE SERIES 1-5/16" (33,3 mm)I TY-FRB 13/16' (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT 2-7/8' DIA. - 5/8±1/4" (73,0 mm) 3/4' (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. I 1/4' (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) \% MOUNTING SURFACE SERIES 1-1/4"(31,8mm) CLOSURE TY-FRB 3/4" 19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT 2-7/8' DIA. (73,0 mm) 1/2±1/8" I 1/2' (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) MOUNTING SPRINKLER PLATE FACE OF / [572 mm) 4P777-7 FITTING 1/8" (3,2 mm) \%!_ SURFACE t MOUNTING CLOSURE SERIES (33,3 mm) TY-FRB 1-1/16' (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 IN. NPT - 2-7/8" DIA. (73,0 mm) 1/2±1/8" 1/2' (12,7 mm) (" DIA. 12,7±3,2 mm) 2-1/4 1/4" (6,4 mm) I FACE OF mm) m MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) J MOUNTING SURFACE 1 CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 IN. NPT 0 TFPI7I Page 6 of 10 2-7/8' DIA. - 5/8±1/4' (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4' DIA. 1/4 (6,4 mm) / FACE OF •:: (57,2 mm) MOUNTING __ _______ -'/r__ PLATE I SPRINKLER FITTING 1/8 _ -I ___ _____ (3,2 mm) MOUNTING / 4 SURFAC7 SERIES 1-1/4' (31,8 mm) CLOSURE TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 5/8±1/4' (15,9±6,4 mm) 2-1/4" DIA. - 1/4" (6,4 mm) / (57,2 mm) FACE OF MOUNTING SPRINKLER I PLATE I FITTING - _____ __ _____ (3,2 mm) 4 -/:_1/8" MOUNTING /' SURFAC>// CLOSURE SERIES 1-5/16" (33,3 mm)I TYFRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT - WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "E" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH 2-7/8" DIA. -. (73,0 mm) 1/2±1/8" 11/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4' (6,4 mm) I FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE I I FITTING 1/8" (3,2 mm) I _- MOUNTING SURFACE 7 SERIES 1-1/4'(31,8 mm) 1 CLOSURE TY-FRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) - 2-1/4" DIA 1/4" (6,4 mm) / FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" T_ \ MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TYFRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI7I Page 7 of 10 Sprinkler Finish5 K- Type Type Temperature Bulb Liquid Color Natural Brass Chrome Plated Polyester 2.8 1/2 in. NPT Pendent (TY1231) and Upright (TY1131) 135°F (57°C) Orange 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent (TY1231)a Figure 6 135°F (57°C) Orange 1,2,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F(93°C) Green Recessed Pendent (TY1231)b Figure 7 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 4.2 1/2 in. NPT Pendent (TY2231) and Upright (TY2131) 135°F (57°C) Orange 1,2 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Recessed Pendent (TY2231)a Figure 8 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Recessed Pendent (TY2231)b Figure 9 135°F (57°C) Orange 155°F (68°C) Red 175° F (79°C) Yellow 200°F(93°C) Green NOTES Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion- resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS S TFPI7I Page 8 of 10 Sprinkler Finish8 K- Factor Type Temperature Bulb Liquid Color Natural Brass Chrome Plated Polyesterc Poly.Stainlessc Lead Coated Pendent (TY3231) 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow and 1, 2, 3, 4, 5, 6, 7 1,2 1,2,3,5 Upright (TY3131) Blue 200°F (93°C) Green 286-F (141-C) 135°F (57°C) Orange 155°F (68°C) Red 5.6 1/n NPT Recessed Pendent (TY3231)a Figure 10 1, 2, 4, 5 1,2 N/Ad 175°F (79°C) Yellow 200°F (93°C) Green 286°F(141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3231)b 1,2,3,4,5 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 11 286°F (141°C) Blue Pendent (TY4231) 135°F (57°C) Orange 155°F (68°C) Red 175°F(79°C) Yellow and 1, 2, 3, 4, 5, 6, 7 1,2 1,2,5 Upright (TY4131) Blue 200°F (93°C) Green 286°F(141°C) 135°F (57°C) Orange 155°F (68°C) Red 8.0 3/4 in NPT Recessed Pendent (TY4231)a Figure 12 1, 2, 5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286-F (141-C) Blue 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY4231)b Figure 13 1, 2, 3, 5 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F(141°C) Blue 8.0 Pendent (TY4931) 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 1/2 in. and 1, 2, 4, 5, 6 N/A 1, 2, 5 NPT Upright (TY4831) Blue 200°F (93°C) Green 286-F (141-C) NOTES Installed with Style 10 (1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT( or Style 30 (3/4 in. NPT( 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Not Available (N/A) Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL( as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Faa 31-53-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS 0 TFPI7I Page 9 of 10 Sprinkler Finish K- Factor Type Natural Brass I Chrome Plated I Polyester Lead Coated Pendent (TY1231) and 2.8 upright (TY1131) 1/2 in. 175 psi (12,1 bar) N/A2 NPT Recessed Pendent (1Y1231) Pendent (1Y2231) and 4.2 Upright (TY2131) 1/2 in. 175 psi (12,1 bar) N/A NPT Recessed Pendent (TY2231) Pendent (TY3231) and 5.6 Upright (TY3131) 250 psi (17,2 bar) 1/2 in. or 175 psi (12,1 bar)' NPT Recessed Pendent (TY3231) Pendent (TY4231) 175 psi 8.0 and upright (TY4131) (12,1 bar) 3/4 in. 175 psi (12,1 bar) NPT Recessed N/A Pendent(TY4231) 8.0 Pendent (TY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831) NOTES The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. UL); the Listing by Under- writers Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Not applicable (N/A). Care and Maintenance The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to TABLE C MAXIMUM WORKING PRESSURE corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be taken to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). Initial and frequent visual inspections of random samples are recommended for corrosion-resistant sprinklers to verify the integrity of the corrosion-resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice.Inspections of corrosion-resis- tant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprinkler condition and the long-term integrity of the corrosion-resistant material, which can be affected by the corrosive conditions present. FINISH 1 NATURAL BRASS - POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 - POLYESTER PURE WHITE - POLYESTER (RAL9010)2 SIGNAL WHITE - POLYESTER (RAL9003) JET BLACK - POLYESTER (RAL9005)3 7 LEAD COATED 9 I CHROME PLATED TFPI7I Page 10 of 10 P/N 57- XXX- X- XXX I I SIN SPRINKLER 330 2.8K UPRIGHT (1/2 in. NPT) TY1131 331 2.8K PENDENT (1/2 in. NPT) TY1231 340 4.2K UPRIGHT (1/2 in. NPT) TY2131 341 4.2K PENDENT (1/2 in. NPT) TY2231 370 5.6K UPRIGHT (1/2 in. NPT) TY3131 371 5.6K PENDENT (1/2 in. NPT) TY3231 390 8.0K UPRIGHT (3/4 in. NPT) TY4131 391 8.0K PENDENT (3/4 in. NPT) TY4231 360 8.0K UPRIGHT (1/2 in. NPT) TY4831 361 8.0K PENDENT (1/2 in. NPT) TY4931 TEMPERATURE RATINGS I 135 155 I 155°F(68°C) 175 1 175-F (79-C) 200 1 200°F (93°C) 286 1 286°F (141°C) NOTES Available only on TY3131, TY3231, TY4131, and TY4231 Eastern Hemisphere sales only. Available in only 2.8K, 4.2K, and 8.0K, 155°F (68°C) and 200°F (93°C); requires longer lead time to manufacture. TABLED SERIES TV-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 C 1400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +11-2115-362-0700 ,jj P 02018 Johnson Controls. All right, rnaePand. All aponifisaliona and othor information shown waro oarrnnl an of document ronisiRn dab and are oablnst In change without notion. Johnson '1' +(' NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered ,tOdemgrhs of National Fire Protection ASsonlorlon; TEFLON Is a registered tr005rnanl, Of DuPont Controls Jt WheatlandTube JMC STEEL GROUP 700 South Dock Street Wheatland, PA 16146 800.257.8182 40 www.wheatland.com Wheatland ASTM A 53 Schedule 40 and Schedule 80 Pipe Wheatland Steel Pipe is made by specialists who understand that it's the small details that make the difference between average products and superior products. At the Wheatland Plant, most department heads and foremen have been employed in some phase of pipe manufacturing for 25 or more years. This kind of specialization, experience and knowledge pays off.. .in workable, threadable, uniform pipe. Delivered clean. Delivered promptly. Wheatland specializes in manufacturing welded steel pipe in 1/2 through 4 nominal sizes. Available inventory in 1/8 to 12 pipe sizes produced to various ASTM standards is maintained to meet your pipe requirements. Care, pride and personal concern are bonus features that go into every inch of Wheatland Pipe. Don't settle for less. Make sure it's quality. Make sure it's Wheatland. Standard Pipe Schedule 40 ASTM A 53 Grades A and B Outside Diameter Inside Diameter Wall Thickness Nominal Weight (Mass) per unit Length NPS Designato DN (Inches) (mm) Designator Plain (Inches) (mm) (Inches) (mm) End (lb/if) Plain End (kg/rn) Threads & Threads & Couplings Couplings (Ib/ft) (kg/m 1/8 6 0.405 10.3 0.269 6.8 0.068 1.73 0.24 0.37 0.25 0.37 1/4 8 0.540 13.7 0.364 9.2 0.088 2.24 0.43 0.63 0.43 0.63 3/8 10 0.675 17.1 0.493 12.5 0.091 2.31 0.57 0.84 0.57 0.84 1/2 15 0.840 21.3 0.622 15.8 0.109 2.77 0.85 1.27 0.86 1.27 3/4 20 1.050 26.7 0.824 20.9 0.113 2.87 1.13 1.69 1.14 1.69 1 25 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.50 1.69 2.50 1-1/4 32 1.660 42.2 1.380 35.1 0.140 3.56 2.27 3.39 2.28 3.40 1-1/2 40 1.900 48.3 1.610 40.9 0.145 3.68 2.72 4.05 2.74 4.04 2 50 2.375 60.3 2.067 52.5 0.154 13.91 3.66 5.44 3.68 5.46 2-1/2 65 2.875 73.0 2.469 62.7 0.203 5.16 5.80 8.63 5.85 8.67 3 80 3.500 88.9 3.068 77.9 0.216 5.49 7.58 11.29 7.68 11.35 3-1/2 90 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.57 9.27 13.71 4 100 4.500 114.3 4.026 102.3 0.237 6.02 10.80 16.07 10.92 16.23 5 125 5.563 141.3 5.047 158.2 0.258 6.55 14.63 21.77 14.90 22.07 6 150 6.625 168.3 6.065 154.1 0.280 7.11 18.99 1 28.26 1 19.34 28.58 8 200 8.625 219.1 7.981 202.7 0.322 8.18 28.58 42.55 29.35 43.73 10 250 10.750 273.0 10.020 254.5 0.365 9.27 40.52 60.29 41.49 63.36 Standard Pipe 121 1 300 12.750 323.8 12.000 1 304.8 1 0.375 1 9.52 49.61 73.78 51.28 76.21 Note' NPS 12 dimensions are for standard wall pipe, not schedule 40. ProductType and Specification: Standard welded pipe is produced in 1/2 to 6 trade sizes. Wheatland pipe is produced to ASTM A 53 Grades A and B, A 501, and A 589 Type II, API 5L and Federal Specification WW-P404. All pipe threads conform to ANSI 131.20.1. Merchant couplings comply with ASTM A 865. Specifications and descriptions are accurate as known at time of publication and subject to change without notice. '1ID 11111IRON eI'IDEG. ELBOW I NOMINAL SIZE (INCH) I ITEM CODE I MAX. WORKING P.S.I. IDIM ENSIONSI WEIGHT I A B EACH PIECE I DB90033 500 1.50 1.50 0.62 1114 DB90044 500 1.75 1.75 0.90 1112 1 DB900551 500 1 1.94 1.94 1 1.20 2 1 DB900661 500 1 2.25 1 2.25 1 1.85 I DUCTILE I RONI 1 illilDEG. E LBOWj NOMINAL SIZE (INCH) ITEM CODE MAX. WORKING P.S.I. DIMENSIONS WEIGHT - A - B EACH PIECE 1X1/2 DB90031 500 1.26 1.36 0.44 1X3/4 I DB90032 500 1.37 1.45 0.52 I 1/4X1/2 DB90041 500 1.34 1.53 0.64 I 1/4X3/4 DB90042 500 1.45 1.62 0.72 I 1/4X1 DB90043 500 1.58 1.67 0.75 I 1/2X1 DB90053 500 1.65 1.80 0.92 I 1/2X1 1/4 DB90054 500 1.82 1.88 1.08 2X112 DB90061 500 1.49 1 1.88 1.08 2X3/4 DB90062 500 1.60 1.97 1.24 2X1 DB90063 500 1.73 2.02 1.40 2X11/4 DB90064 500 1.90 2.10 .52 2X11/2- DB90065 500 2.02 2.16 1.65 DUCTILE IRON COUPLING NOMINAL SIZE (INCH) ITEM CODE # ' MAX. WORKING P.S.I. IDIMENSb0i WEIGHT EACH PIECE A I DCL033 500 1.67 0.40 11/4 0CL044 500 1.93 0.57 11/2 DCLO55 1 500 1 2.15 0.75 2 DCL066 1 500 1 2.53 1.15 DUCTILE IRON 45 DEG. ELBOW NOMINAL SIZE (INCH) I ITEM CODE # ' MAX. WORKING P.S.I. 'DIMENSIONS I WEIGHT I A B EACH PIECE I DB45033 500 1.12 1.12 0.46 11/4 DB45044 500 1.29 1.29 0.73 11/2 DB45055 500 1.43 1.43 0.92 2 1 DB450661 500 1.68 1.68 1.50 DUCTILE IRON STRAIGHT ccl:.TEE NOMINAL SIZE (INCH) ITEM CODE # ' MAX. WORKING P.S.I. 'DIMENSIONS WEIGHT' - A B EACH PIECE I DT333 500 1.50 1.50 0.85 11/4 DT444 500 1.75 1.75 1.22 11/2 DT555 500 1.94 1.94 1.55 2 DT666 500 2.25 2.25 2.45 I DUCTILE IRON!RED. COU I [c NOMINAL SIZE (INCH) ITEM CODE # MAX. WORKING P.S.I. DIMENSION WEIGHT EACH PIECE A IXI/2 DRC03I 500 1.69 0.39 1X3/4 DRC032 500 1.69 0.53 C D.I. THREADED FITTINGS LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Ductile iron threaded fittings are UL, ULC listed and factory mutual approved for 500 psi service. Ductile iron per ASTM A 536 grade 65-45-12. Dimensions conform to ANSI 1316.3 y class 150. Threads are NPT per ANSI/ASME B1.20.1. 13 NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittingd should be tightened theree turns beyond hand tight, but no more than four turns. STAR ®PIPEPRODUCTS Page 21 El. SHE) Iewqns jsenbei S8OIM9S uo!pejojd eij joj G3A0JddY aaLsn aasn <*> : oqq IV SDNII.LEI aav3IH1 Ta S13[1UOmcfk1IJ®WV1S Nor, 1~ off T774 m '4W1H711 1jul4 I'4Illu ;zI 1 i.i i;ir 'XVW ki.II.I 21 9NI3fl0èI NOM 31113na Oi. WI. 009 toxa 9P I. 091. 991. 009 csoxa i.xn. 1. LII. L9 991. 009 tPDX0 I.XP/L I. 96 009 990X0 061. V61 P61. 009 ssoxa iii. 1. 091. SL SVI. 009 PPDXO I P/I. I. 960 091 091. 009 CCOXO I. 333Id HOV3 9 V - ISd 9NI)I0M 'XVW # 3003 Mil (HONI) 3Z1S 1VNIVl0N I .LH9M ISN0ISN3VJI0 SSONOINONIF I! kill' e I.60 SP I. 009 900d30 090 Cc' I. 009 900d30 III. I. £PO 9I. 009 P00d30 P/I. I. CO 91.1. 009 £00d30 1. 3331d H3V3 I J9M V iSd _______ ONDIdOM IN0ISIBINI0I 'XVW # 3003 I IlB1I (HONI) 3ZIS 1VNILN0N dVO [iI I F II kill' I.9'O mO orz PE0 890 S9HSfl90 in IX L0 IflO arz P50 99*0 P9HSfl90 in I.X 99'0 NI 961. 1.P0 980 £9HSfl90 I.X 050 .Lfl0 00 1.50 590 PSHSfl90 P/I. 1.X/I I. PP•0 mO 00 1.50 CWO E9HSfl90 I.X/I. I. 90 mO 9L1. I 9Z0 080 £PHSfl90 1.XP/I. I. LI.0 .Lfl0 zv1. 90 SL0 ZCHsnea P/CXI. .Lfl0 in S0 9L0 I.EHSflBO zan H3V3 31A.LS 3 9 V 30o3 Vi31I (H3NI) MIS 1VNILØI0N SN0ISN3VII0 ]II:lI:u sIIFI PkIIIu V3H 3GISNI avH aismno i 2 SAMMYS® FOR WOOD No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Wa a udeo demonst,atica atl www.itwbuildex.comJ i - #14 Black Nut Driver Part # 8113910 i . #14 SW Red Nut Driver Parl# 8114910 1/4" 8002957 GST 100 1/4 xl 210 (7/16OSB) 25 125 [ 1/4" 8003957 GST 200' 1/4x2" - 1760 (Fir) - 25 125 3/6" 8007957 GST 10 1/4 x1" 210 (7/16"OSB) 300 25 125 3/8" 8008957 GST2O 114x2" 1760 (Fir) 850 1475 25 125 8068925 GST 2G-SS 1/4x2" 1760 (Fir) 850 25 - 125 - - — 3/88009925 GST 25-380 3/8x21/2" 2113 (Fe) 1500 25 125 3/6" 8010957 GST 30 1/4x3" 2060 (Fir) - - 1500 1475 25 125 1 3/8 - 8069925 GST 30-SS 1/4 x 3 2060 (Fe) - - 25 125 1/2" 8013925 GST 2 1/4 x 2 1760 (Fir) 25 - 125 r - 1/2 8015925 GST 3 1/4 x3 2275 (Fir) 25 125 M"JUUFACTURED = 17 Qil USA SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. NAW f~w%~MYS Not less than 2' nominal width (1-1/2") up to 3-1/2" pipe; not .ess than 3" (2-1/2') nominal width 4" & 5" pipe Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of 1 f steel beams. _________________ No pre-drilling required. "Quick to install using the Sammy Floor Joist Nut Driver with an 18V cordless drill/driver Saves time from traditional methods. ' Reduces installation costs. Manufactured in the U.S.A. Wsta ,deo dam Oar at) www.ilwbuildex.comJ o 8319957 -3 .8.320957 a 3/8' - 8021957 ll 114 I ...." 873925 - 3/8" 8022925 #14 SW Red [ - 3/6" 8023925 Nut Driver Pert #8114910 * May require pre-drilling; consutt joist manufacturer SWG 200 1/4x2 1725 (Fir) 25 125 - SWG 10 1/4x1" 622 (Fir) 300 25 - 125 SWG 20 1/4 x 2' 1725 (Fir) 1050 25 125 SWG 20-SS 1/4x 2" 1725 (Fir) 850 25 125 SWG 25-380 - 3/8x2-112" 2249 (Fir) - 1500 25 125 - SWG 30 114x3" 1884 (Fir) - 25 - 125 Eliminates distortion of threaded rod. Accommodates up to 3 W x 12 pitch roof. "Allows 17" deflection from vertical. Saves time from traditional methods. Reduces installation costs. "Manufactured in the U.S.A. Black cWIY14U2[.1IJi NutDriver - - 3/8" 8139957 SH-GST2O 114x2" - 1257 (Fir) Part#8113910 1903 Dim. Lumber Q. 3/ 8269957 SH-GST/CST 20 5/16x 1-3/4" 1406 @ 45off vertical Dim. Lumber 903 Dim. Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45"olf vertical Dim. Lumber * May require pre-drilling; consult joist manufacturer. #14 SH Orange Nut Driver Pert # 8273910 1500 850 @45" 25 125 25 125 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 Fire Protection Solutions B-Line by E1.N Pipe Clamps S Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe** Double Fastener Strap Side Mounted (B-Line B3183) Size Range: 3/4" (20mm) thru 2 (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUI) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4" 3< 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the I ) product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact I j tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a I./ pilot hole in wood is required. V Finish: Pre-Galvanized , Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the - product and is the minimum fastener size acceptable. ** With reduced spacing, consult factory. OTQLCO Ic @us LISTED CPVC Max. Hanger Fastener Hex Approx. S Pipe Size A B C Spacing Head Size Wt./100 Part No. in. 1mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-/4 3/4' (20) 2/16' (58.7) 1/32' 127.81 1/16' (30.2) 51/3 (1.67) /it' (7.9) 9 (4.1) 24-1 1' (25) 2/8' (66.7) 1/16' (33.3) 1/16' (30.2) 6 (1.83) /16' (7.9) 9 (4.1) 24_11/4 11/4 (32) 3" (76.2) 11/2 138.11 1/16" (30.21 61/2 (1.98) /16' (7.9) 11 (5.0) 24-11I2 11/2 (40) 31/4 182.51 1/8" 142.31 1/16' (30.2) 1 (2.13) /16" (7.9) 12 (5.4) 24-2 2' (50) 311/16' (93.7) 127/32' (43.6) 1/16' (30.2) 8 (2.44) /16" (7.9) 15 (6.8) Fig. 25 - Surge Restrainer C @ r Size Range: - One size fits 3/4 (20mm) thru 2 (40mm) pipe. LISTED Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band ::......... .• / - hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13 2010 edition 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUI). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from S 3/4" (20mm) thru 2" (40mm). Patent #5,344,108 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 94 Fire Protection Solutions B-Line by Ei.N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) ®TOL. CCY B32051 - Threaded Rod (right & left hand threads) 0 Size Range: 3/8"-1 6 thru 3°-4 rod Material: Steel TL Function: Recommended for use as a hanger support in hanger assemblies. Specify Length Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) TL Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Thread Size Order By: Figure number, rod size, length and finish Standard Design Load Thread Size Thread Length TI 650°F (343°C) 750°F (399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-/ x V 318"-16 21/2" (63.5) 130 (3.25) 572 (2.54) B3205-1/2 X 'L 1/2°_13 21/2 (63.5) 1350 (6.00) 1051 (4.70) B3205-518x 'L /8"-11 21/2" (63.5) 2160 (9.61) 1692 17.521 B3205-3/4 x /4"-10 3° (76.2) 3230 (14.37) 2530 (11.25) B3205-1/8 x /811-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog. ATR - All Threaded Rod (TOLCO Fig. 99 & Fig. 100) Size Range: /"-16 thru 11!2'6 rod in 10' (3.05m) lengths Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Note: Fig. 99 is cut to length all threaded rod. Fig. 100 is full length. Part No. Threads Recommended Load Approx. Wt.I100 Ft. & Size Per Inch Lbs. (kN) Lbs. (kg) AIR 1/4" x '1' 20 240 (1.07) 12 (5.44) ATR /8" x'1' 16 730 13.241 29 (13.15) ATR 1/2" x'1' 13 1350 (6.00) 53 (24.04) ATR 5/g" x'1' 11 2160 (9.60) 89 (40.37) ATR 3/4" x'1' 10 3230 (14.37) 123 (55.79) ATR hg" x '1' 9 4480 (19.93) - 170 177.111 For larger sizes consult full line pipe hanger catalog. RM Fig. 200-1/2. 200-/4 Fig. 20021I2 to 200-8 Fig. 200 Fig. 200S Pipe Hangers ®TOLCO' c@ us LISTED . Fig. 200 - 'Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: 11/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications \MN-H-171 F & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343 be supplied with (2) hex °c) Finish: Pre-Galvanized. Stainless Steel -. materials in ' t5 l er By: Figure 1 and pipe T Designed to meet or exceed requirements of Fig. 200C Fig. 200F Pipe Size Rod Size A B Approx. Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) /8"-16 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) /8"-16 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200-1 1" (25) /8"-16 3/8" (85.7) 2/8' (66.7) 12 (5.5) 200_11/4 11/4" (32) /8"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) /8'-16 3/e' (98.4) 2/8" (73.0) 14 (6.4) 200-2 2" (50) /8"-16 41/2" (114.3) 3' (76.3) 15 (6.9) 200-21I2 21/2" (65) /e"-16 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3' (75) /8"-16 5/8' (149.1) 4" (101.6) 29 113.31 200-31I2 31/2" (901 /8"-16 1/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7/8" (187.3) 5" (127.0) 35 (16.0) 200-5 (125) 1/2"..13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 (150) 1/2 .13 101/8" (257.2) 6/4" 1171.41 73 133.41 200-8 8" (200) 1/2 .13 131/8" (333.4) 8/4" (222.2) 136 162.31 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 21 by Ei.N