Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2724 LOKER AVE W; ; FPC2018-0120; Permit
4LC ityof PERMIT REPORT Carlsbad Print Date: 12/02/2020 Permit No: FPC2018-0120 Job Address: 2724 LOKER WEST AVE W, CARLSBAD, CA 92010-6603 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2090812800 Track #: Applied: 04/24/2018 Valuation: $13,953.00 Lot #: Issued: 05/01/2018 Occupancy Group: Project #: Finaled Close Out: 12/02/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: PLANET INNOVATION -SPRINKLER TI (64 HEADS) Applicant: FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION AMERICAN AUTOMATIC FIRE SUPPRESSION INC INC JAllMIN DEEKEN 9925 PROSPECT AVE, #STE B 9925 PROSPECT AVE, # B SANTEE, CA 92071 SANTEE, CA 92071 (619) 562-3010 (619) 562-3010 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov F tqco Fire Protection Products Worldwide www.tyco-fire.com Contacts Series TY-B - 28, 56, and 80 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers described in this technical data sheet are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commer- cial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TY-B Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler systems and components. Improper hand/mg and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. FILTOMM The Series 1Y-B Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contract the installing contractor or product manufacturer with any questions. Sprinkler Identification Numbers (SINs) TY1151 - Upright 2.8K, 1/2"NPT TY1251 - Pendent 2.8K, 1/2-NPT TY3151 - Upright 5.6K, 1/2"NPT TY3251 - Pendent 5.6K, 1/2" NPT TY4151 - Upright 8.0K, 3/4" NPT TY4251 - Pendent 8.0K, 3/4" NPT TY4851 - Upright 8.0K, 1/2" NPT TY4951 - Pendent 8.0K, 1/2" NPT NOVEMBER 2014 TFPI5I TFPI5I Page 2 of 8 CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 7/16 _________ / 2-1/4 1 4 -Bulb (11,1 mm) NOMINAL (57,2 mm) / r 7 3 - Sealing 6 - Deflector* Assembly 7 - Bushing * Temperature rating is MAKE-IN 1-9/16 _______ indicated on Deflector. 23/16 (39,7 mm) (55,6 mm) - 5 ** Pipe thread connections 6* per ISO 7-1 can be provided on special 1/2 NPT** WRENCH request. FLATS UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TY-B UPRIGHT (TYI15I) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT STANDARD RESPONSE 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING SURFACE j 7/16 _ T(5 NOMINAL 316 (11,1 mm) // 6 mm) MAKE-IN 1-1/2' (38,1 mm) I (55,6mm) A / - 1/2' NPT** I WRENCH STYLE 10 - 2-7/8" (73,0 mm) DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 SERIES TV-B UPRIGHT 'TY3151) AND PENDENT ('TY3251) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE TFPI5I Page 3 of 8 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE L4~ _ 1/2 1 NOMINAL I T(5 MAKE-IN (12,7 mm) 2-1/4 7 mm) 1-9/16 I (39,7 mm) (57,2mm) 3/4" NPT** tWIRE CH STYLE 40 1------ 2-7/8" (73,0 mm) DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT FIGURE 3 SERIES TY-B UPRIGHT 'TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT, STANDARD RESPONSE CROSS SECTION CEILING PLATE SEATING SURFACE 7 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) 1 - Frame 5 - Compression 2 - Button Screw 1 3 - Sealing 6 - Deflector* Assembly 4-Bulb 2 * Temperature rating is 4 indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. CROSS SECTION \ 7/16" 1 I MAKE-IN NOMINAL 11 MAKE-IN I 2-3/16" 1/2" NPT** t WRENCH FLATS UPRIGHT PENDENT FIGURE 4 SERIES TV-B UPRIGHT (TY4851) AND PENDENT 'TY4951) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE TFPI5I Page 4 of 8 K SPRINKLER TYPE TEMPERATURE RATING LIQUID COLOR BULB SPRINKLER FINISH (8) NATURAL BRASS CHROME I PLATED I I POLYESTER*** I LEAD COATED I WAX I COATED WAX-OVER-LEAD COATED 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT 2.8 NPT (TY1151) and PENDENT (TY1251) 1, 2, 3 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Figure '1 Blue 360°F(182°C) Mauve 1,2 135°F (57°C) Orange 155°F (68°C) Red 5.6 112° UPRIGHT (TY3151) and PENDENT (TY3251) Figure 2 1, 2,3,4,5,6,7 Green 1,2,3,5 1,2,3,5 1,2,3,5 175°F (79°C) Yellow 200°F (93°C) 286°F (141°C) Blue 1°°, 2°°, 3**, 5** 2**, 3** 360°F (182°C) I Mauve N/A NPT 135°F (57°C) Orange 155°F (68°C) Red RECESSED PENDENT (TY3251)* 1,2,3,4,5 N/A 175°F (79°C) Yellow 200°F (93°C) Figure 5 Green 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F (68°C) Red 8.0 3/4 UPRIGHT (TY4151) and PENDENT (TY4251) Figure 3 1, 2,3,4,5,6,7 Green 1,2,5 1,2,3,5 1,2,5 ° 175F (79°C) Yellow 200°F (93°C) 286°F (141°C) Blue 2**, 3** 2°°, 5** 360°F (182°C) Mauve N/A NPT 135°F (57°C) Orange 155°F (68°C) Red RECESSED PENDENT (TY4251)* 1, 2,3,4,5 N/A 175°F (79°C) Yellow 200°F (93°C) Figure 6 Green 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F (68°C) Red UPRIGHT 8.0 NPT (TY4851) and PENDENT (TY4951) 1, 2,3,4,5,6 N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Figure 4 360°F (182°C) Mauve I Notes: Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) Approved by FM Global (FM Approvals) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k103) Approved by the City of New York under MEA 354-01-E VdS Approved (For details contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094aJ05) Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion- Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. Installed with Style 10 (1/2 NPT) or Style 40 (3/4 NPT) 3/4Totsl Adjustment Recessed Escutcheon, as applicable 150°F (66°C) maximum ceiling temperature Frame and deflector only N/A - Not Applicable TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFPI5I Page 5 of 8 SPRINKLER FINISH K TYPE NATURAL I CHROME POLYESTER* LEAD WAX WAX-OVER-LEAD BRASS PLATED COATED COATED COATED 2.8 UPRIGHT (TY1I5I) 1/2" and 175 psi (12,1 bar) N/A NPT PENDENT (TY1251) UPRIGHT (TY3151) and 5.6 PENDENT (TY3251) 250 psi (17,2 bar) (a) 1/2" OR NPT 175 psi (12,1 bar) RECESSED PENDENT (TY3251) UPRIGHT (TY4151) and 175 psi (12,1 bar) 8.0 PENDENT (TY4251) 3/4" NPT RECES2 51) J1DENT 175 psi (12,1 bar) N/A 8.0 UPRIGHT (TY4851) 1/2" and 175 psi (12,1 bar) NPT PENDENT (TY4951) Notes: a. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL), the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL), and the Approval by the City of New York. * Frame and deflector only N/A - Not Applicable TABLE B SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE Technical Data Approvals UL and C-UL Listed FM Approved LPCB Approved VdS Approved NYC Approved (Refer to Table A for complete ap- proval information, including corro- sion-resis-tant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K=2.8 gpm/psi112 (40,3 tpm/bar112) K=5.6 gpm/psi112 (80,6 1pm/barl/2) K=8.0 gpm/psi112 (115,2 1pm/barl/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table C. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame .......................Bronze Button..................Brass/Copper Sealing Assembly.......Beryllium Nickel w/TEFLON Bulb .........................Glass Compression Screw............Bronze Deflector.....................Copper Bushing (K=2.8) ...............Bronze Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Global Loss Prevention Data Sheets). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. 2-7/8 DIA. 5/8±1/4 (73,0 mm) 3/4 (19,1 mm) (15,9±6,4 mm) 2-1/4 DIA. 1/4" (6,4 mm) FACE OF (57,2 mm ? MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-B 3/4" (19,1 mm) FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING - DI AT [ 1/8 (3,2 mm) 1-5/16" (33,3 mm) 13/16 (20,6 mm) FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT 5/8±1/4 (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES Ty-B TFPI5I Page 6 of 8 WRENCH RECESS (END A USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B USED FOR 3/4" NPT MODELS) FIGURE 7 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Obtain a leak-tight 3/4 inch NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. TFPI5I Page 7 of 8 Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions: Note: Install pendent sprinklers in the pendent position; install upright sprin- klers in the upright position. Step 1. With pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 7). For wax-coated sprinklers, use an 8 or 10 inch adjustable wrench. With reference to Figures 1 through 4, the W-Type 7 Recessed Sprinkler Wrench or an adjustable wrench, as applicable, is to be applied to the sprinkler wrench flats. When installing wax-coated sprinklers with an adjustable wrench, exercise care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment. Open the jaws of the wrench sufficiently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprinkler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating when- ever the coating has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 inch diameter steel rod to the damaged areas of wax, to smooth it back over areas where bare metal is exposed. LL.)tL.JI Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precau- tions need to be taken when handling the heated rod in order to prevent the installer from being burned. Recessed Pendent Sprinklers The Series TY-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step A. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 8). With reference to Figure 3 or 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 10 or 40 Closure over the Series TY-B Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance TYCO Series TY-B, 2.8, 5.6, and 8.0 K-factor, Upright and Pendent Sprin- klers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to Installation Section.) The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFPI5I Page 8 of 8 P/N 57 - XXX - X - XXX SIN -] 530 2.8K UPRIGHT (1/2" NPT) TY1151 531 2.8K PENDENT (1/2" NPT) TY1251 570 5.6K UPRIGHT (1/2"NPT) TY3151 571 5.6K PENDENT (1/2" NPT) TY3251 590 8.0K UPRIGHT (3/4" NPT) TY4151 591 8.0K PENDENT (3/4" NPT) TY4251 560 8.0K UPRIGHT (1/2" NPT) TY4851 561 8.0K PENDENT (1/2" NPT) TY4951 Notes: Eastern Hemisphere sales only ** Available in only 8.0K, 155°F (68°C) or 200°F (93°C); requires lead time to manufacture Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems ("OPEN" indicates sprinkler assembly without glass bulb, button, and sealing assembly) I TEMPERATURE I SPRINKLER FINISH RATING 1 NATURAL BRASS 1 35 135-F (57-C) PURE WHITE (RAL9010)" 155 155°F (68°C) POLYESTER - SIGNAL WHITE (RAL9003) 175 175°F (79°C) POLYESTER - JET BLACK (RAL9005) ** 200 200°F (93°C) POLYESTER - 6 WAX COATED 286 286°F (141°C) 286°F (141°C) MAX - 7 LEAD COATED 360 360°F (182°C) 8 WAX-OVER-LEAD 000 OPEN""" 286°F (141°C) MAX 9 CHROME PLATED TABLE C SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating, P/N (Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with (specify) finish, P/N* ° Refer to Technical Data Sheet TFP770 Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench-damaged wax coating) Specify: (specify color, below) Colored Coded Wax Stick for retouching (specify temperature rating) temperature-rated Series TY-B Sprinklers, P/N (specify) Black for 135°F (57°C) ......P/N 56-065-1-135 Red for 155°F (68°C) .......P/N 56-065-1-155 Yellow for 175°F (79°C) .....P/N 56-065-1-175 Blue for 200'F (93°C) and 286°F (141°C) .........P/N 56-065-1-286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. Note: The wax used for 286°F (141°C) sprinklers is the same as for 200°F (93°C) sprinklers, and, therefore, the 286°F(141°C) sprinkler is limited to the same maximum ceiling temperature as the 200°F (93°C) sprinkler (i.e., 150°F [66°C]). GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqcci TEFLON is trademark of the DuPont Corporation. Fire Protection Products 11 Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature Pressure Class 150 Class 250 Class 300 (°F) (°C) psi bar psi bar psi bar 200 to 1500 -28.9° to 300 65.60 20.7 500 34.5 600 41.4 2000 93.30 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 185 12.8 360 24.8 460 31.7 3500 176.70 150 10.3 315 21.7 415 28.6 4000 204.40 110 7.6 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 22.4 5000 260.00 - - 180 12.4 280 19.3 550° 287.8° - - 130 9.0 1 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F c®Us <:S~> APPROVED For Listings/Approval Details and Limitations, visit our website © www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. Malleable Iron Threaded Fittings Pressue - Temperature Ratings Temperature Pressure Class 150 Class 300 __________ Sizes 'A-i" (6-25 mm) Sizes 11/4 -2" (32-51 mm) Sizes 2'/x'-3" (64-76 mm) (°F) (°C) psi br psi bar psi bar psi bar -20° to 1500 28.90 o 300 20.7 2,000 65.60 137.9 1,500 103.4 1,000 68.9 2000 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 2500 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 3000 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 3500 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 5000 260.0 - - 510 35.2 450 31.0 1 385 26.5 5500 287.8 - - 300 20.7 300 20.7 1 300 20.7 Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 anc Unions conform to ASME B16.39. ALL ELBOWS & TEES %" (10 DN) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) www.anvilintl.com 17 U irni 0pVTDCO4 best sprinkler in the industry! c®us LISTED <> APPROVED Do 4 Ameican Fir. NFPA BULL MOOSE TUBE COMPANY - I - AIM WA ell— c®us LISTED <> APPROVED I;]ONFSA NFPA sr.. Bu ll Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception 11, of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com E 10 ; \ sales@bullmoosetube.com 800.325.4467 ••• V I - / BULL IV100SE TUBE COMPANY Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED <9> APPROVED U;] Z4 NFPA ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masur Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. [ddythrcad 400: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube® reserves the right to change product specifications without notice and without incurring obligation. c®us LISTED <> APPROVED [; 4;F EA NFPA SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE SIZE (IN) 0.D. (IN) I.D. WATER FILLED (IN) CRR** WEIGHT/FT WEIGHT BUNDLE SIZE 1 1-114 II 1.315 1.660 i 1.097 -1527 - JL141 lbs/ft 1820 r 9.9f IL 1.81 iTft11 2.518 j[ 91 61 11/2 1.900 1fl1682 776 1 2 [_75 1=2.11577F-6.27 _4223 IL__37 J 21/2 2.875 2.635 492 353 R,s/ft 5.893 -30 I _3 fl_3_5001[___3260 1L_354 Ifl4 34 I6s/fF1I_7 9 - 7[ _19 —] 4.500 4.260 r250 —5.6-2- 16s/ 1T796 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 - 1315 1_ 1 00 168 lbs/ft 2055 70 j L 11/4 r_1660 ][_f380 11_100 J[11fFL_2918_II_51 ] 11/2 j1900][1610 100 - 272 1bs/ft 3.662 44 [ _2 1L 2375 11_2067 __JI 100 11ILfF1L 5.114 11 30 j L_21/2*I 7____Z._875 _~__2468 00 580Ibs/ft 7875 _30- 3*][ 3.068 1.00 _1.00 j[ _7.58 Iff1l _10.783 [_ij 4* 4.500 - - - 4.026 _1 00 _1 1-0-801 _16-3116 19 - *only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande AZ Dallas D( Masury, OH BULL MOOSE TUBE COMPAP.W 63017 B ull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. FireLock® Outlet-I ® ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11% through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para Location - Approved Date www.victaulic.com ICTALIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV G 10.52 1 DIMENSIONS PS CARBON STEEL PIPE HOLE CUT PRODUCTS FireLock® Outlet-I STYLE 922 Nominal Size F Dimensions ,i.iflt1I Ili tmeters II,10 Owl' 1¼ ½ 1 3A6 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 -Y4 1 3A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 13A6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1½ ½ 1 /io 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 '/4 1 3A6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13A6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 16 13A6 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 1 116.8 65.0 0.59 3/4 1 3A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 - 41.7 55.6 37.1 116.8 65.0 0.64 1 13A6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2112 ½ 1/6 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3% 1 /6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 1 48.0 62.0 43.4 137.2 65.0 0.73 1 1/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 ½ 11/16 1.91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 3/4 1 3A6 1.89 2.44 1.71 5.50 2.56 1.6 20 -30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1 3A6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 1 0.80 f Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com viclAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 2 \JtauIic REV G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-T STYLE 922 PERFORMANCE Run Size x Outlet Size Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 161 (C=120)*, FT Ft/ters 32 25 11/2 Ihimrn 50 1 I 40 25 25 L.1•uiu * Hazen-Williams coefficient of friction is 120 www.victaulic.com - VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. taulic Pry ( 1O2 14 FireLock® Outlet-T STYLE 922 INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 A—C—ta—ulicr VIcTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vIcTAULIc COMPANY. ALL RIGHTS RESERVED. 10.52 'IAcn P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org RING HANGER I thru 4 Inch pipe LISTED FOR STEELICPVC 1/2 & 3/4 Inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - I;@ us LIVED 203-EX 2551 1"- 8" Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MS S-SP-5 8 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPAI3 PIPE ROD I WT. 5 WT.+250 UL TEST LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/8 76.95 634.75 750 21/2 3/8 118.35 841.75 850 3 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 1/2 476.35 ~ ~Z222 6 2631.75 8 1/2 711.00 '/AcSn P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON#300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - Sus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. 551 5_ s_S 554 ,_ Specific AFCON products are exclusively designed lobe compatible ONLY with other AFCONproducts including parts and fasteners, resulting mu listed sway brace, restrainer or banger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCOA'. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to lass af business or profit, when non-AFCON products have been, or are used. 1/08 - Not less than Product Features 2" nominal width 4l1-1I2l "No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. -4- S A Czn .,, 1/4 8002957 GST 100 1/4x1" 210 (7/16"OSB) 670 (3/4" Ply) 1/4" 8003957 GST 200 1/4x2" 1760 )Fir) 25 125 414BCI( ut Driver 1/4" 8004957 GST 300 1/4 x 3" 2_(Fir) 25 125J 3/8" 8006957 GST.75 1/4x3/4" 564 (3/4" Ply) 25 125 3/8 8007957 GST 10 1/4 X1" 210 (7116" CSB) 300 25 125 1 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 1/8" 8068925 GST 20-SS 1/4 x 2 1760 25 125 ] 3/8" 8009925 GST 25-380 3/8x2-1/Z' 2113 (Fir) 1500 25 125 3/8 8010957 GST 30 11.43." 2q6(F) 1pQ 1475 5 125] 3/8" 8069925 GST30SS 1/4x3 2060 (Fir) 25 125 Pad #8113910 3/8" 8011925 GST 40 1/4x4 2180 () 25 125 1 3/8" 8012925 GST 60 1/4x6" 2230 (Fir) 25 125 - 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125I #14SWRed 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 112_8015925 GST3 1/4x3"2275 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 1/2" 8017925 GST6 1/4x6 2230 (Fir) 25 125 1 Nut Driver Pad # 8114910 _--- ?-"' 3/8" 8141957 SH-GST3O 1/4x3" 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Pad #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 25 125 T FfAM Product Features Eliminates distortion of threaded rod. "Saves time from traditional methods. Accommodates up to 3 h/2fl x 12 pitch root. • Reduces installation cost Allows 17 deflection from vertical. • Made in the U.S.A. IT - /1aLKn>3/A"A139q57SH-GST2O1/4x2_1257( Fir t1050 1475 25125125 11 (. IN Floor Joist Product Features No pre-driving required. 'Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation cost Made in the U.S.A. Not less than 2' nominal width (1-1/2') up to 3-1/2' pipe; not less than 3' (2-1/2') nominal width 4' & 5' pipe I / Minimum 2-1/2' from bottom for / / ) branch lines. Minimum 3' from /1 1 bottom for mainlines. Exception: This / J / requirement shall not apply to 2' or thicker nailing strips resting on top of steel beams. I - #14 SW Red Nut Driver 1/4 8018957 SW 100 114 XL 622 25 125 .j 1/4' 8019957 SWG200 1/4x2" 1725 (Fir) 25 125 3/8 8020957 SWGIO 1/4x1 622 jFJ 300 2 . 125 ......j 3/8' 8021957 SWG20 1/4x2' 1725 (Fir) 1050 25 125 8073925 SWG2O_SS 1/4x2_1725( Fir) 850 25 125 3/8' 8022925 SWG25-380 318o2-1/2' 2249 (Fir) 1500 25 125 3I8_8023925 SWG3O 114x 1884(Fir)25 125 1 Pad #8114910 - & STEEL.-',I F STALLAfft STEP J ØINTO WOOD & STEEL Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs, for maximum pullout in purlin steel. Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. ORR SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.