HomeMy WebLinkAbout2791 LOKER AVE W; ; FPC2020-0112; PermitPERMIT REPORT ((7city of Carlsbad Print Date: 11/05/2020 Permit No: FPC2020-0112 Job Address: 2791 LOKER AVE W, CARLSBAD, CA 92010-6601 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2090814800 Track 4*: Applied: 07/02/2020 Valuation: $0.00 Lot 4*: Issued: 07/16/2020 Occupancy Group: Project 4*: Finaled Close Out: 11/05/2020 #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4*: Inspector: Plan Check 4*: Final Inspection: Project Title: Description: METROPOLITAN LIFE INSURANCE - COMMUNICATOR ADDITION TO AN EXISTING FIRE ALARM SYSTEM TO REPLACE PHONE LIN WITH CELLULAR SIGNAL FOR SPRINKLER SYSTEM REMOTE STATION SERVICE BY 24 HR U.L. APPROVED CENTRAL STATION Applicant: FPContractor: JOHNSON CONTROLS SECURITY SOLUTIONS JOHNSON CONTROLS SECURITY SOLUTIONS LLC LLC - DO NOT USE ABBY VAUGHAN 3870 MURPHY CANYON RD, 4* 140 3870 MURPHY CANYON RD SAN DIEGO, CA 92123-4403 SAN DIEGO, CA 92123-4403 (561) 226-8210 (858) 837-2488 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov flPcZ020 Oltz- HIGHLIGHTED SET Cut Sheets and CSFM Listing Sheets For: Metropolitan Life Insurance 2791 Loker Avenue West Carlsbad, California 92010 Installer: Johnson 01(i Controls tqcn iitegra ted Security 3870 MURPHY CANYON ROAD SUITE 140 SAN DIEGO, CA. 92123 (800) 289-2647 LIC #977249 (C-b, C-7) L3 SILENT "5104B Fire ControI 0 KNIGHT Communicator by Honeywell The speed, reliability and value of digital communications from the company you can trust As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B Fire Control Communicator has become the industry standard by proving itself in years of field-tested operation. This six-zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions. It transmits via ordinary phone lines - eliminating the need for expensive leased line arrangements. Use it as a stand-alone, or incorporate it into your existing system. Why spec any other digital communicator? Go with the industry standard - the 5104B Fire Control Communicator from Silent Knight. For more information, please call 1-800-328-0103. Model 51046 Fire Control Communicator The Silent Knight Model 5104B is a six-zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It's UL 864 and NFPA 72 approved for monitoring local evacuation controls. As a stand-alone unit, it can be used to monitor: Sprinkler systems for waterflow, supervisory, and gate valve tamper conditions. Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to the central station. If one of the telephone lines faults for more than 60 seconds, it will automatically switch to the other to report the failure. The communicator will signal activation, restoration and trouble conditions on any of six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two-wire type smoke detectors, instead of the normal four-wire contact type, for automatic fire detection applications. Features UL 864 Listed as an NFPA 72 Central Station or Remote Station protected premise unit. FM approved. Can be used as a stand-alone or as a add-on DACT. Six fully supervised inputs: one Class A (Style D) input, and five Class B (Style A) inputs. Downloadable for remote programming. Fuseless overload protection with automatic reset circuitry and fault indicators - eliminates the cause of most field calls. Dual phone line interface Automatic self tests every 24 hours with report sent to central station. Reports in SIA and most major communications formats. 60 hours of standby power. Operates on loop start phone lines ahead of the building PBX system. A single, programmable output is provided for alarm or dialer failed conditions (cannot be used for evacuation purposes). 5104B Fire Control Communicator Specifications Electrical Add-on Applications - UL Listed Input: 120 VAC 60 Hz 40 watts Current: Standby 50 mA Alarm 135 mA Stand Alone Applications Input: 120 VAC 60 Hz 40 watts Standby: 12 volt 7 amp hour rechargeable battery 5230 Remote Annunciator (three maximum per system) Load: 60 mA standby 120 mA alarm Indicator Lights (LEDs): Power On (Green) Trouble Silenced (Yellow) Until Trouble is Cleared/Flashing = Supervisory Dialer Failure (Yellow) Telephone Line Fault (2 Red) Inside Cabinet at Li and L2 Inputs Telephone Requirements: FCC Registration #: AC698R-17462-AL-E RINGER EQUIVALENCE 0.013 Type of Jack: RJ31X (2 required) Mechanical: 12.25 W x 14.5 H x 3.0' D (31.1 cm W x 36.8 cm H x 7.6cm D) 15 lbs. (6.75 kg) Red - 5230 Remote Annunciator/Programmer 5561 Download Package 7181 Fire Zone Converter Module 7860 Telephone Connecting Cord for RJ31X Jack (2 required) 6712 12 volt, 7AH rechargeable battery Communication Formats: SIA, SK 3/1, Sescoa 3/1, Contact ID, 5K 4/2, Radionics BFSK Approvals: UL Listed - UL864/NFPA 72 Central and Remote Supervising Station Fire Alarm System Service. FM Approved CSFM Approved MEA Dimensions: Weight: Color: Optional Accessories: .ou - EMMM - ANNUWIATO I woman== Model 5230 Model 5230 Remote Alphanumeric Annunciator The 5104B can be programmed through the use of the optional Model 5230 Remote Alphanumeric Annunciator. Programming options include: telephone numbers, reporting format, account number, loop response times (electronic retard), test time, output activation, user and installer codes. System programming is stored in a non- volatile EEPROM chip which is reprogrammable hundreds of times The 5104B accommodates up to three remote annunciators via a four-wire connection. .A quick- connect plug allows temporary connection of the annunciator for programming. The Model 5560 SKSS Downloading Package Allows for remote programming and status checking of the 5104. Includes a 3 1/2-inch disk and Silent Knight proprietary modem. Allows the installing company to view the default programming, modify it, and if necessary, troubleshoot the system. Designed to be used on an IBM or compatible PC. The downloading software also contains programs for other Silent Knight downloadable products. 5 1/4-inch disks available upon request.. 6 Channel Communicator Silent Knight Model 5230 (optional) Remote Annunciator (3 max per system) Tel. Line #1 Model 6712 To RJ3IX I2VDC 7 AH Tel. Line #2 0) / ..... Wheelock MB-GIO-12-R 5104B Fire Control Communicator I20VAC 60 Hz UL-LISTED LOCAL FIRE SILENT KNIGHT CONTROL MODEL 5104B 6 Channel Communicator Alarm Contact Trouble Contact ilent Knigh Model 5230 (optional) Remote Annunciator (3 max per system) TeL Line #1 To RJ3IX Tel. Line #2 MODEL 5104B BLOCK DIAGRAM Add-On DACT Application SILENT KNIGHT MODEL 5104B I20VAC 60 Hz Class A Input (supervised) c--- Max 5 waterfiow devices as per NFPA 72 rc Class B Inputs (supervised) Gate valve tamper or Ply supervisor- must connect normally open LE MODEL 5104B BLOCK DIAGRAM Stand-alone Waterfiow Application 5104B Fire Control Communicator I20VAC 60 Hz Class A Input (supervised) SILENT KNIGHT MODEL 5104B 6 Channel Communicator Silent Knight Model 5230 (optional) Remote Annunciator (3 max per system) 0- Class B Inputs 0- (supervised) P I Heat detectors, manual pull stations and h contact type Model 6712 _____________ smoke detectors i 12VDC7AH Tel. Line #1 Tel. Line #2 To RJ3IX / Wheelock MB-GI 0-12-R (optional) MODEL 5104B BLOCK DIAGRAM Stand-alone Automatic Fire Detection Application (For Communication Only) ARCHITECT/ENGINEER and send the alarm signal on one or The digital communicator shall provide SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing The contractor shall provide an more equipment. It shall test each rechargeable batteries. The secondary approved digital communicator to telephone line (number) at alternating supply shall be capable of supplying transmit the fire alarm and supervisory 24-hour intervals in accordance with power, under maximum normal load, and trouble signals to a central station. NFPA 72. It shall sound a local trouble for 24 hours for central station or The digital communicator shall be UL signal if the telephone service is proprietary applications or 60 hours for or FM listed for fire reporting to a interrupted for longer than 60 seconds remote supervising station system central station and shall conform to the and it shall transmit a signal indicating application in accordance with NFPA requirements of NFPA 72. the loss of phone line service to the 72. The digital communicator shall provide central station over the remaining phone line. A signal shall also be The communicator shall be able to transmit all signals in the Standard SIA power and necessary components for transmitted to indicate the restoral of format (Security Industry Association). six supervised detection circuits. One phone service. The shall be Class A (Style D) and five shall control/communicator shall be able to The alarm signals transmitted to the be Class B (Style A). The detection report the loss of either phone line central station shall indicate which of circuits shall accommodate sprinkler without regard to which phone line the six zones is in alarm and which flow switches, gate valve supervisory failed first. If both lines fail, a local zones are in trouble. Restoral from switches, thermal detectors and signal shall sound. alarm or trouble shall be capable of contact-type smoke detectors intermixed as desired and permitted by The control/communicator shall have communicating to Silent Knight, and other industry standard receivers. NFPA 72. the ability to send a test signal to the central station every 24 hours. The test The control/communicator shall have signal shall be able to be transmitted at the capability to supervise two a specific time of day or night by telephone lines, seize the phone line setting a program within the panel. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information D up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are PN 350349, Rev Cl subject to change without notice. For more information, contact Silent Knight ©2010 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7165-0559:0114) Page 1 of 1 CATEGORY: (7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL)) LISTEE: (1LENT KNIGHT SEC URITYQFire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: (Model *5104B Provides automatic, manual and waterflow service)when used as a central station protective premise unit. Intended to monitor various initiating devices and transmit to a central station receiving unit various preprogrammed alarm and trouble signals. Refer to listee's data sheet for detailed product description, electrical rating and operational considerations. *5104B *Six zone control/communicator control unit 5230 Remote annunciator/keypad INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed control unit for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: Refer to listee's data sheet for required/optional accessories. When required, accessories shall be CSFM listed. *Rev. 08-01-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Ds. (June 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (T G 7-;7F '1L /N: CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS. TELGUARD 8 COMMERCIAL FIRE PRODUCT FEATURES . Certified for use on Verizon's LTE networkfor long, sunset- free installation. I Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-V transmits alarm signals from the-fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LTE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently, dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being ableto signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new sixty minute supervision mode. The TG-7FS LTE-V can also be installed as a backup path and upgraded to sole path at a. later date. UL Listings Commercial Fire 864 Control units & accessories for lire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 1023 • Household burglar alarm systems For the most current product specifications and UL Listings visit www.Telguard.com. "I TELGUARD TG-7FS LTE-V P/N: TG7LVFO1 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS o 1)=swWYY an At knj~ jjt o iTianscej r inten na JB s: 9 0lewrth2B a1 I' SbTEV'75"HxP.IWx35! Ship pingWeight8lbs rating Environment to g 0C up to 95% hum idity onsiflg). Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna.' EXDL-0: External antenna. an tu es FflI dta reriorting. Automatic self-test (60 mm. Power s VIEWii bttejy hajjiess. Lqpking, re mQtal enclose. Two prograjabe sujsoy trip outputs. Supps viTtlly all alarm fTh5ts (ontact ID, Sl2, and others) usij dial captue for ugiysal panel compatmlility. Telephone ii rie monitiltLn' with Stan ad L Telguard, a Division, of Telular corporation 3225 Cumberland Blvd SE - Suite 300 Atlanta, GA 30339 USA 800-229-2326, Option 5• www.Telguard.com • Copyright ©2017 Telular corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE f LISTING No. (00-1402:0110) Page 1 of.1 CATEGORY:Alarm Control Unit Accessories/Misc. Devices) LISTEE: . (TELULAR CORP., 322 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models *1G7LV001 *1G7LVA01 '(JG7LVF01 anJTG-KIT(JtaI cellular communicator) CsyjModels are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04072017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an 'J endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ftv requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2019 (June3O,2) Authorized DAVID CASTILLO, Program Coordinator Fire Engineering Division Nominal Voltage 12V Rated Capacity 7Ah Dimensions Total Height 3.98 inches (101mm) Height 3.74 inches (95mm) LengtlL 5.94 inches (151mm) Width 2.56 inches (65mm) Approximate Weight 4.52 lbs. (2.05kg) I. 65 DISCHARGE CHARACTERISTICS AT 250 C(770 F) 0 > I I 2 3 5 ID 20 30 60 2 3 5 10 20 30 H 0 Discharge Time CHARGED I 220 VOLUME_......___-- - CHARGED 80 010 2.15 VOLTAGE 2 200 00 CHARGING CURRENT Chargeing Time (5) Cycle service life C.) __--__I __ 0 - - - I 200 400 600 800 1000 1200 Life (Cycle) POE R KINGDOM (Sealed Lead-Acid Batteries) PS712 (12V7A10 Specifications I Characteristic Capacity 77°F(25°C) 20h rate 7.00Ah 10h rate 6.50Ah 5h rate 5.95Ah ih rate 4.20Ah is min rate 3.15Ah Internal Resistance Full Charged Battery 770F(250C) 25m 0 Capacity Affected by Temperature (20h rate) 104°F(40°C) 102% 77°F(25°C) 100% 320F(0°C) 85% 50F(-150C) 65% Self-Discharge 68°F(20°C) (Capacity after) 3 month storage 90% 6 month storage 80% 12 month storage 60% Max. Discharge Current_77°F(25°C) 105A(5s) Terminal Ti , T2 Charge (Constant Voltage.250C) Cycle 14.5'..14.9V(-24mV/°C) I I max. current: 2.1 A Float 13.6- 13.8V(-18mV/0C) Cnnctoiit C.,rr&nt flioiehooro Choirneteri6tiee (A2' F.VITIME 5min 10mm 15min 30min 60min 3h 5h 10h 20h 9.60V 27.0 18.0 14.0 8.40 4.70 1.73 1.15 0.71 0.37 10.2V 25.7 17.1 13.4 8.06 4.55 1.70 1.13 0.70 0.36 10.5V 24.2 16.1 12.7 7.66 4.35 1.65 1.10 0.68 0.35 Constant Current Diacharp Characteristics (Watt.25C F.V/TIME 5min 10mm 15min 30min 60min 3h 5h 10h 20h 9.60V 301 203 160 94.2 54.4 20.6 13.8 8.52 4.43 -10.2V 287 191 153 90.4 52.7 20.2 13.6 8.40 4.33 10.5V 270 180 145 86.0 50.4 19.6 13.2 8.17 4.21 ACE-Il (FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock Will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooksto organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder-for key contacts Overall Dimensions are 12" x 13" tall and 2 ¼ deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information IS09 1 [ Electronics Inc. MadeIS.A Space 07] IAO . REGIRE/'www.Isalcom' NFPA 800.486.1723 Toll Free COMPANY MEMEMM msm~ n u 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 No Excuses Just Solutions! ED0549 LT10559 Rev.D 1/2 , SPACE AGE ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface - Requires Standard USB- Connector Key Ring Hooks Business Card Holder Property Intomootlon Mininnon, Required Documentation (SIG-FUN) CertIfIcatIons andApprovals 16,1 Sy61e,rr IrroteIIeIiorr Controclorl , cooro*.uc.,o.s.roo*ca .n,o, 54 0.00 00.4111*41 40*lia01..dM,.o4000io ,00*0..olili .40*0 _____________ renlp.,40000joald06.0005 t*.m 16.5 rtoltl01lty Having Jurisdiction: .,5*0*.od01400W.11tO.0d00W500l.0t Iv0bg.01000.tit0.ro0064*0.U0.*00.0*lii.b oFPoO.4060600411* , 9C0.l46141*d1*410.00Oit941110it,0*06,nL6.l47t2 Eqolpnnent Intornoatlon 1.151 00 :.o**rt.-ooao 5.0105. S4 - 0I400A4500000n'Oo, 00 t00004i*.0R05d 0604,4111.01561 *0,455.0101 00*00*00,0 1010644 0.0.1 Legend sheet for storing system information- including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just SOlutions! Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED) S5U00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal* disclaimer ED0549 LT1 0559 Rev.D 2/2 SECTION2 FIRE ALARM CABLE PART NUMBER AWG 1 CONDUCTOR SHIELDED! I OVERALL UNSHIELDED DIAMETER CONDUCTOR - JACKET VOLTAGE WEIGHT . MARKINGS FTEmp COLOR COLOR - RATING (Ibs))Unit - UPS - I BLACK, WHITE, I WHITE I 300v I 18.0 I A01494469 I 60°c 500 RED, GREEN, LBS 12/C 22 AWG REEL BROWN, BLUE, TYPE FPLP/ CkjP ORANGE, YELLOW, CNIP (I L) VIOLET. GRAY, PINK. TAN - - -- BLACK. RED RED 16.0 -- 1000 LBS TC18AWG ) BOX PE 8.0 ADT 493490 500 LBS 2/C I8AWG BOX TYPE FPLP/ ,- CMP - (UL) - - LIGHT BLUE, 16.0 AD1493493 60°C 1000 YELLOW LBS 2IC18AWG BOX TYPE FPLP/ ,- CMP (Ii) (UL) 8.0 ADI 493493 500 LBS 2/C 18AWG BOX TYPE FPLP/ ,.- CMP - - - (UL) - - I 2.20 DON'T SEE IT? CALL 1-888-423-8947 ORDERS: PHONE 1-888-423-8947, FAX 847-797-3853 M 2.21 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. (7161-2075:0100) Page 1 of 1 CATEGORY: (7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: ge Eiectric CompanyiSpringfield Road, Union, NJ 07083 Contact: Cindy Regner (908) 687-7810 Fax (908) 687-8860 Email: cregner@paigeelectric.com DESIGN: Types FPL, P and FPLR power limited fire protective signaling cables. Insulation - PVC compound AlphaGary Smokeguard 4010, Synergistics 1349-1028 FRD, 1360-1021-PID, PP, HDPE or LDPE. Shields - (Optional) All metal or Aluminum Polyester tape. Braid - (Optional) All metal. Jacket - PVC compound AlphaGary Smokeguard 11 6920, Gitto Global GA-8705-03, AIphaGaryGW2038, Synergistics 1690-1060, 1604-1007 FR, 1100-1092 FRD, JAP61Aor 1410-1011 FRD, Solef 31008-0003. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, Type FPL, FPLP or FPLR, rating and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. NOTE: Formally 7161-1677100 XLF: 7161-1509:0100 mt 09-09-11 mt , •k This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 (Listing Expj (June 30, 2020) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division