HomeMy WebLinkAbout1850 MARRON RD; 112; FPC2018-0390; Permit(7city of Carlsbad Print Date: 12/14/2021 Job Address: 1850 MARRON RD. # 112, CARLSBAD, CA 92008-1174 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 1563011600 Track U: Valuation: $94,182.75 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Permit No: FPC2018-0390 Status: Closed - Finaled Applied: 12/03/2018 Issued: 12/12/2018 Finaled Close Out: 02/01/2021 Inspector: Final Inspection: Project Title: Description: CODE NINJAS -SPRINKLER TI (26 HEADS) RELOCATE/ADD NEW PENDENT SPRINKLER PROTECTION FOR NEW SUSPENDED CEILINGS Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, USTE 14 1341 DISTRIBUTION WAY, U STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE Hourly Services Each Additional Hour $136.00 FIRE Hourly Services First Hour $159.00 FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $848.00 Total Payments To Date: $848.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov A jITAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 18725 CODE NINJAS 1850 Marron Rd. Suite 112 Carlsbad, CA 92008 FPC20I8-0390 1850 MARRON RD #112 CODE NINJAS - SPRINKLER TI (26 HEADS) RELOCATE/ADD NEW PENDENT SPRINKLER PROTECTION FOR NEW SUSPENDED CEILINGS 1563011600 1 2/1212018 FPC20I8-0390 FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Technical Specifications: Upright, Pendent and Recessed Pendent Standard and Quick Response Models: V2703, V2704, V2707, V2708 JtauIicr 40.10 r A'Z'~ 4. V27031V2704 V2707/V2 708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: CE 0786 See Victaulic Publication 1001 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to I4719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 CO 2014 Victaulic Company. All rights reserved. 1 ictaulic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: El Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: El Open End: V27 El Recessed: V27-2 Sprinkler Finishes: LII Plain Brass El Chrome plated El White painted3 El Black painted3 El Custom painted3 El Proprietary Nickel Teflon2 coating3 El VC-2504 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 2 A~C__t:a_ulicr victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 4010 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor SI.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135"F/57"C 135°F/57°C 155"F/68°C 155°F/68°C 135°F/57°C 135"F/57"C 135°F/57°C 135°F/57°C 175"F/79"C 175°F/79°C 155°F/68°C 155"F/68°C 155°F/68°C 155"F/68"C cULus 200°F/93°C 200°F/93"C 175"F/79"C 175°F/79°C 175°F/79°C 175°F/79°C 286" F/141 "C 286"F/141°C 200°F/93°C 200°F/93°C 200"F/93°C 200" F/93"C 360°F/182°C 360°F/182"C 286"F/141 "C 286°F/141°C 286°F/141°C 135"F/57°C 135°1757°C 135°F/57"C 135"F/57°C 155°F/68°C 155°F/68"C 135"F/57"C 155°F/68°C 155"F/68"C 135"F/57"C FM 175"F/79°C 175"F/79°C 155°F/68°C 175°F/79°C 175°F/79"C 155°F/68"C 200"F/93°C 200"F/93°C 175"F/79°C 175°F/79°C 286°F/141°C 286" F/141 °C 200°F/93"C 200°F/93°C 200°F/93°C 200"F/93°C 360°F/182"C 360"F/182°C 286°F/141°C 286°F/141°C 135"F/57"C 135"F/57°C 135"F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68"C 155"F/68"C 155°F/68"C 155°F/68°C 135°F/57°C NYC/MEA 62-99-E 175°F/79"C 175°F/79"C 175"F/79"C 175"F/79°C 175°F/79°C 155°F/68°C 200°F/93"C 200°F/93°C 175°F/79°C 286" F/141 "C 286" F/141 "C 200"F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360"F/182"C 286°F/141°C 286°F/141"C 286"F/141°C 1351/57"C 135°F/57"C 155"F/68°C 155°F/68°C 135°F/57"C 135°F/57°C 135"F/57"C 135°F/57°C 175°F/79"C 175"F/79"C 155°F/68 °C 155°F/68°C 155°F/68°C 155°F/68"C CSFM 7690-0531:112 200"F/93°C 200°F/93°C 175"F/79"C 175°F/79"C 175°F/79°C 175°F/79°C 286°F/141"C 286°F/141"C 200"F/93"C 200°F/93°C 200°F/93°C 200°F/93"C 360°F/182°C 360°F/182"C 286°F/141 "C 286°F/141°C 286°F/141°C 135°F/57°C 155"F/68"C 135"F/57"C LPCB 175°F/79°C None None 155"F/68"C None None 200°F/93"C 175°F/79°C 286°F/141°C 200"F/93°C 360"F/182°C 135°F/57°C 135°F/57°C 135"F/57°C 135°F/57°C 155°F/68°C 155" F/68"C 135°F/57"C 155"F/68"C 155"F/68"C 135°F/57°C VNIIPO 175°F/79°C 175"F/79"C 155"F/68°C 175"F/79°C 175"F/79"C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175"F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 360"F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155"F/68"C None 2007/93°C 200°F/93°C 200"F/93"C 200"F/93"C 135°F/57"C 155"F/68"C 155"F/68"C VdS 175°F/79°C None None 175"F/79°C None None 200"F/93"C 200°F/93°C 286°F/141°C 286"F/141"C 360"F/182"C 135°F/57°C 135"F/57°C 155"F/68"C 155" F/68"C CE 175"F/79"C None None 175°F/79°C None None 200°F/93"C 200"F/93"C 286"F/141°C 286"F/141"C 360°F/182°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with /2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 102014 Victaulic Company. All rights reserved. victaulic.com 3 \JtauIic victaulic.com I Sprinklers I FireLocke I K5.6, V27 I Publication 40.10 Dimensions: 6C 65 Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/6O mm Max. Hole 2/51 mm Mix. Hole Typical Ceiling Tile 30 17 mm Finished Isurface Y 30rm 43 mm MAXIMUM RECESS 2aAx / - 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) am inc mm Max. Hole 2'751 rn 15A6"1 17A6"/ 24 mrn "A6V Typical Ceiling Tile 37 mm Finished Surface 24 nm MAXIMUM RECESS 215A6/ 75 mm MAXIMUM EXTENSION 3/4"Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 Aic--ta-uhcr victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent Distribution Patterns - Trajectory 64• -----.---,--.--\— 4;•- —..-- — \. — _ IIIIiiiiIIS)sJii 2' 4 8' 10' 12' 14' 0.6,,, 1.2,,, iBm 2.4m 3.0m 3.7rn 43m Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory %. '•S%,,, '. 2' 4' 6' 8' 10' I?' 14' 16' 0.6m l.2, Lam 2.4m 3AM 3.7m 4.3m 4.9m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 \4taulicr 10' 3am a, 8' 2,1m 6' 1.8m 4' 1.28, 2' 0.6m 0 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - Fl C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 Ff57 C 100 F/38 C Orange Ordinary C 155 Ff68 C 100 F/38 C Red Intermediate E 175 F/79 C 150 Ff65 C Yellow Intermediate F 200 Ff93 C 150 Ff65 C Green High J 286 Ff141 C 225 F8f107 C Blue Extra High 7 K 360 F/182 C 300 Ff149 C Purple - M Open - No Bulb Standard response only. 8150/65 if wax coated. V27-2 Recessed V27 Open End V2707, V2708 Pendent / .1 V2707, V2708 Recessed Pendent / - V2703, V2704 upright I WARNING I Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. LIM Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in POP format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is registered trademark of Victaulic Company. 40.10 2544 Rev. J updated 07/2014 W 2014 Victaulic Company. All rights reserved. victaulic.com 6 \J1'taUIiC Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose TubeA made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube'sO Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED APPROVED rol A,,PJ!fL4 (!II FPX ..--- 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. SIZE (IN) (IN) I.D. (IN) CRR** WEIGHT/FT WATER FILLED WEIGHT BUNDLE SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 776 209 lbs/ft 3.053 61 2 2.375 2.157 6.27 '2 ' 64 1b/f ' 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.266 354 4341bsIft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 227 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 100 3661b5/ft 5.114 30 2-1/2* 2.875 2.468 1 00 580 lbs/ft 7875 30 3* 3.500 3.068 1.00 7.58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10,80 lbs/ft 16.316 19 'Only available in Casa Grande, AZ "corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald. MO Kent WA Casa Grande, AZ Dallas IX Maourt OH 63017 Dull Moose Tube's" Eddythread40® ADVANTAGES OF BULL MOOSE TUBE® EDDVTHREAD 40® I.) is lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDVTHREAD 40® SPECIFICATIONS c®is LISTED APP000M i:; OSA NFPA' ,"- NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR LB/FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 'Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. A <"f For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U 1819 Clarkson Road chesterfield, MO Gerald, MO KerstWA Casa Grande AZ Dallas, TX Masur8 OH 63017 5 Bull Moose Tube's® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2". Eddylite® is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®tjs LISTED APPROVHI [; 4 pia A NFPX '-'- 1 6 ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. 'Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 11/4 1.660 1.482 008 479 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 016 431 2.617 4.230 37 *Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ 0allasjX Masurt OH 63017 Dull Moose Tube's® Eddy Flows ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® I.) is specially engineered Certified to ASTM Al 35 and A795 Type E, Grade A. replacement for Schedule 10, FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well Lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD Il® MIC preventative coating. economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, NPS O.D. EDDY FLOW° EDDY FLOW WEIGHT WATER FILLED BUNDLE Eddy Flow's® larger ID provides SIZE (IN) (IN) (ID) CRR° PER FT. WT. SIZE an opportunity for downsizing and further cost savings.1-1/2 1.1/4 1.660 1.530 1.98 1.222 2.019 61 1.900 1.728 344 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 '1.00 --4.968" 11.290 19 'Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED AI'PIIOVEU NFPA' Q For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Case Grande, AZ Dallas TX Masust OH 63017 7 Dull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® I.) a versatile product that can be Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedules approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. 'With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 :2.375 2.261 1.00 1.604 3.344 37 Pressfit is a Registered Trademark of Victaulic Company of America ** Corrosion Resistance Ratio per latent Ut. Directory Listing c®us LISTED APPHOVTh [;]4.. ONf4 NFPA' --- 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. C~ ® For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Claticton Road Chesterfield, MO Gerald, MO Kent,wA Coo® Grand AZ Dallas, TX Masurt OH 63017 NIPS (IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 c®us LISTED 10.D.(in) 1.315 1.660 1.900 2.375 10(m) 1.201 1.546 1.786 2.261 ULTRA EDDYO Empty Wei ght (lb"0.868 1.107 1.274 1.604 Water Filled Weight Ob/ft) 1.359 1.920 2.360 3.344 2.17 1.40 1.11 1.00 Dljn) 1.660 1.900 2.375 2.875 3.500 4.500 1. D. (in) 1530 1.728 2.203 2.705 3.334 4.310 EDDY FLOW Empty Weight (lb/ft) 1.222 1.844 2.330 2.809 3.361 4.968 liledWeightOb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R.1.98 3.44 2.78 1.66 1.00 1.00 OD (in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 r i.D.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE EmptyWeightOb/ft) - 1 410 1,810 2.090 2.640 3.530 4.340 5.620 10 Tater.FiIled Weight Ob/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 CRR 1527 991 776 627 492 354 250 00 On 1.315 1.660 1.900 2.375 iflOn 1.137 1.482 1.712 2.177 EDDYLITE Empty Weight Ob/h) 1.260 1.617 1.967 2.617 ter F0ed Weight (lb/It) 1.700 2.364 2'965 4.236 0.13 0.08 ' 0.12 0.16 ':. 0.D.(in) . 1.295 1.650 1.900 2.375 EDDYTHREAD 10(m) 1.083 1.418 1.645 2.123 400 eiitOb/ft 1 461 2070 2547 3308 lmpty Water-Filled Weight(mb/ft) 1.860 2.754 3.468 4.842 C.R.R. - 1.00 1.00 1.00 1.00 [ 0.D.(mn) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 ID.(in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE UEmptyWeight/h) 1.680 2.270 2.720 3.660 5.800 7.580 10.800 40 Water-Riled Weight (Ib/ft) 2.055 2918 3602 5.114 7.875 10.783 16.316 CR8 100 100 100 1.00, 100 100 100 Cis A For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gemid. MO Kent; WA Casa Grand AZ Dallas, TX Masuly, OH 63017 APPROIJTh [] A ONFM NFPA' 9 c®ijs LISTED APPROVED 4 OMFSA NFPA 10 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDYO - 0.868 91 1,659 1,896 1,975 [SCHEDULE1O 3 1.410 91 2,695 3,079 3,208 1 rE0DYLITEI 1.260 91 2,408 2.752 2,867 LEDDThREAD40: 1.461 70 2,148 2,454 2,557 - LSCUEDULE 40 rU1TRAEDDY 1.680 1107 70 61 2470 1,418 2822 1,621 2,940 1,688 EDDY FLOW 1.222 61 1,565 1,789 1,864 SCHEDULE10 1810 61 2319 2650 2,760 1114 [ EDDYLITE ' 1.617 61 2,071 2,367 2,466 [EDDYTHREAD40' 2.070 51 2,217 2,534 2,639 [SCHEDULE 4O' 2270 51 2,431 2,778 2894 1E]JLTRAEDDY ' 1.274 61 1 632 1 865 1 943 r EDDY FLOW-1 1 844 61 2,362 2,700 2,812 I SCHEDULE10' 2.090 61 2,677 3,060 3,187 11/2 rEDDYLITE' 3 1.967 61 2,520 2,880 3,000 EDDYTRREAD4O j 2.547 44 2,353 2,690 2,802 rsCHEDuLF40 [ ULTRA EDDY 2.720 1.604 44 37 2,513 1,246 2,872 1,424 2,992 1,484 EDDY FL0W 2.330 37 1,810 2,069 2,1155 L SCHEDIJLE1O 2.640 37 2,051 2,344 2,442 2 EDDY1ITE - 2617 37 2,033 2324 2,421 rEDDYTHREAD400 3.308 30 2,084 2,382 2,481 SCHEDULE 40 EDDY FLOW 3 3.660 2.809 30 - 2,306- 1,770 2635 2,022 2745 2,107 2-1/2 SCHEDULE 10 1 3.530 30 2,224 2,542 2,648 !ScHEDULE4o*1 5.800 3,654 4,176 4,350 - EDDY FLOW' , 3.361 1,341 1,533 1,596 3 SCHEDULE 10 4.340 19 . 1,732 1,979 2,062 - - SCHEDULE 4O 7.580 3,024 3,456 3,601 EDDY FLOVP 4.968 1,982 2,265 2,360 4 1 SCHEDULE 10 J 5620 19 2,242 2,563 2,670 SCHEDULE40 10.800 4,309 4,925 5,130 6' SCHEDULE10 9.289 10 1,951 2,229 2,322 8 ]'SCHEDULElO ' 16.940 7 2,490 2,846 2,965 * Only Available in Casa Grande, AZ. BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) ** According to HLF for the 2006 & 2009 BC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30f1. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1 1544 1 1235 1 1012 1 867 1 726 40 1 40 1 40 1 40 1 40 1 37 1 34 1 32 1 30 1 29 1 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 t 11/2 t2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 c®us LISTED APPROVHI no ONFSA NFPA' ..1 Q For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, TX Masury, OH 63017 11 MechanicaIT® STYLES 920 AND 920N STYLE 920 CROSS PATENTED STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a 'holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-I Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-I unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade °E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location Date Approved www.victaulic.com vlclAuuc IS A REGISTERED TRADEMARK OF VIcTAuuC COMPANY. 0 2017 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_N JtauIic 11.02_i DIMENSIONS Y z V . 6--lit GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 47200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Dimensions Weight Each CTIM, frml _ 2 ½ (a) a 920N 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 50 15 3450 £38.1 51 64 iJ 136 ? 4.1.5 - '/4 (a) a 920N 500 ' 1.50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 4 38.1 50 64 - 41 136 70 1.5 - 1 (a) a 920N 500 1.50 1.85 2.53 1,61 5.35 2.75 3.0 25 - 3450 - L .L .1 Ji 11/4 (a) to 920N 500 1.75 2.05 2.75 1 3.00 1.61 5.35 3.00 -J 3.5 3.2 32 3450 443 52 70 76 41 136 76 1.7 1.5 1½ (a) to 920~ 500 1.75 2.03 1 2.75 "[ 3.12 1.61 5.35 3.25 1 3.6 3.2 40 500 1.50 2.21 2.74 72J79 41 1.82 136 5.64 . 2.75 .11 3.0 L 21/5 1h (a) §a 920N 65 15 3450 38.1 56 70 - 46 143 70 1.4 - '/4 (a) §a 920N 500 1.50 2.18 3.0 2.74 1.82 5.64 2.75 20 3450 i 38.1 55 70 - 46 143 70 1.4 - 1(a) §a 920N 500 1 1.50 2.06 2.74 1.82 5.64 2.75 2.9 25 3450 38.1 52 70 - 46 143 70 1.4 - 1¼ t (a) a 92 N 0 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 1 44.5 58 J, 76 j 83 46 160 76 1.7 15 1 1h t (a) a 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 1 3.3 40 920N 3450 300 50.8 1.50 58 2.22 76 2.75 83 - 46 2.25 159 6.46 83 3.18 1.7 3.9 £ 1.6 761 x ½ (a) 15 2065 38,1 56 70 57 164 81 1.8 ~ (a) 1 920N 300 1.50 2.19 2.75 2.25 6.46 3,18 3.9 20 - - L L _79 . J.± i. 300 2.75 1 (a) 920N 1.50 2.07 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 - 57 164 81 1.7 - 1/a (a) 920N 500 1.75 2.30 3.00 3,31 6.29 3.00 3.5 I 3.2 1.92 32 I - - 500 3.00 11/2 (a) a 920N 2.00 2.28 3.31 1.92 6.29 3.25 3.5 3.3 40 920N 3450 500 50.8 1.50 576 2.52 3.05 84 49 2.28 160 6.15 83 2.75 1641.5 3.4 3 1/2 (a) a 80 15 3450 38.1 64 78 - 58 156 70 1.6 - 'A (a) a 920N j 1.50 2.49 3.05 2.28 6.15 2.75 3.4 , 500 20 3450 38.1 63 78 - 58 156 70 1.6 - 500 1(a) 920N 1.50 2.38 3.06 2.28 6.15 2.75 3,3 25 3450 38.1 61 78 - 58 156 70 1.6 - 1 4 (3) to 32(b) 920N 500 3450 1.75 44.5 2.55 65 3.25 83 3.56 90 2.28 58 ,j 6.15 156 3.00 76 3.8 1.8 3.7 1.8 1½ (a) to 920~ 500 2.00 2.78 3.50 3.56 2.28 6.15 3.25 4.1 3.8 40(b) 3450 50.8 71 89 90 58 , 156 83 1.9 1.8 500 2.50 2 (a) a 920N 2.28 I 6.75 3.88 4 4.9 4.6 50 920N 3450 500 T 3450 63.5 2. 75L~89~jj 70 172 2.3 2.1 3½ 2 90 50 2.50 63.5 3.00 76 2.44 62 6.72 171 3.88 99 3.8 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * center of run to end of fitting. 4 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21h" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in china by Tianjin Approvals Company. www.victaulic.com ictaulicr vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_2 REVN DIMENSIONS Y z GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½"/50 x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N Dimensions TT%TABLE L - - _CONTINUED_FROM_PAGE_2 4 ½ (a) ° 2 N 90 500 1.50 3.03 3.56 2.69 7.01 2.75 3,7 100 15 3450 38.1 77 , 90 4 68 178 70 1 1.8 - 34(a) u 920N 500 1 1.50 3.00 3.56 2.69 7.01 2.75 i 3.7 20 3450 38.1 76 90 - 68 178 70 1.8 - 1(a) o 920N 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1 1.8 - 1 '/ (a) to 920N 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 : 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 I 76 1.9 1.8 11/2 (a) to 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 2 (a) to 3450 500 50.8 2.50 83 3.25 102 I 4.00 102 4.00 68 2.69 178 7.01 83 1 1 3.88 2.0 5.0 1.9 4.6 920N 50 3450 63.5 83 I 102 102 I 68 178 99 2.3 2.1 21h (a) t 920 500 2.75 2.88 4.00 4.00 j 2.69 7.34 4.63 ' t--- 5.8 -. 5.0 65 3450 69.9 73 f 102 102 't 68 2.69 186 118 ' 2.6 2.3 76.1 mm 920 500 3450 69.9 2.88 73 - 4.00 102 6.4 I 68 7.34 186 4.63 I 118 2.9 3 (a) t 920 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 - -. 920N 3.08 114 T 3.78 105 68 2.63 196 7.64 130 + 3.05 ' 38 5.0 29 1 ¼ (a)a 108.0 x 500 I 1.75 32 3450 44.5 -i-.- 78 __•7 96 - I 67 194 78 2.3 - 1 1/2 (a) r1 2 N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 40 3450 50.8 83 102 ... 2 (a) 920N 500 2.50 3.25 4.00 2.63 1 7.64 4.00 : 4.0 so 3450 500 63.5 83 2.88 102 4.00 - 4.00 67 2.63 194 7.64 102 4.29 1.9 - 8.0 - - 7.8 76.1 mm . 920 3450 2.75 69.9 73 102 102 1 67 194 109 3.6 3.5 3 (a) 920 500 3.50 3.31 4.50 4.50 2.63 7.63 + 4.88 6.8 t 6.5 80 3450 500 88.9 2.00 84 J, 4.03 114 4.75 114 4.75 67 3. -16 194 9.70 124 3.69 3.1 7.4 3.0 7.6 5 1½ (a) t 125X 40 3450 920 50.8 102 121 121 80 246 94 3A 3.4 2 (a) t 920 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 3450 63.5 102 121 121 80 246 111 3,7 3.6 21/2 (a) t 920 500 2.75 3.63 4.75 4.75 3.16 9.704-.63- 8.3 79 65 3450 699 92 121 121 80 246 118 3.8 3.6 761 mm u 920 , 500 3450 2.75 69.9 3.75 4.75 3.16 80246i18 9.70 4.63 - 8.0 3 3 (a) t 920 500 3.50 3.81 5.00 4,63 3.16 9.70 5.31 8.4 8.8 80 920N 3450 500 3450 889 2.50 63.5 3.75 95 127 4.50 114-.---.i-- 118 - 80 3.17 81 246 8.00 203 135 3.88 99 3.8 8.0 3.6 40 - 2 133.0 x 50 3 80 _ ...-.- 920 500 3.50 3.81 -.-,.+---..-.......... 5.00 3.00 9.46 5.31 8.0 - 3450 88.9 97 127 - 76 240 135 3.6 _ TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: * Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify 'BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. C 2017 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. REVN JtuIicr 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seat Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Approx. T Max.Work ag Weight Each IM '2]'T " an - TABLE CONTINUED FROM PAGE 3 139. x 7 1½ I' 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 50.8 96 J±J._84 209 83 !. 2.50 2t 920N 500 3.75 4.50 3.30 I 8.23 3.88 9.0 50 0 920N 500 __~3.5 1.75 _25 4.43 5.13 5.13 ±1 3.79 9.15 3.25 5.1 4.8 6 1¼ (a) 150X32(b) 130 96 ..., 1½ (a) 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) 2 (a) to 3450 500 50.8 2.50 , 112 4.38 130 130 .L 5.13 96 3.79 232 9.15 83 3.88 2.4 6.0 2.3 5.6 5.13 920N 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 2 ½ 500 920 2.75 4.01 5.13 5.12 I 3.69 10.51 4.63 8.3 7.6 65 3450 69.9 110 130 130 94 267 ..--. 118 .. 3.8 3.4 761 mm n 920 500 2.75 4.15 5.21 - 3.69 10.51 4.63 8.4 _ 69.9 ~459. 105 132 267 If 3.50 3(a) t 920 500 , 3450 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8,4 80 88.9 [ 110 140 130 94 267 135 4.5 3.8 10.51 4 (a) to 920 500 4.50 1 3.81 5.75 5.38 3.69 6.25 10.1 10.1 100 920N 500 J 2.00 I I 4,41 J.L 2. ! 9.40 3.25 7.8 1 ½(a) 159,0 x 5.13 3.63 40 3450 50.8 112 130 92 239 83 3.5 - 2(a) 920N 500 2.50 I 4.38 5.13 - 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 92 239 99 3.6 - 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 9.40 14.0 92 o 500 3.50 4.31 5.50 5.13 3.63 5.31 8.1 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 108.0mm 500 920 3450 4.50 114.3 4.45 113 I - 5.38 137 3.63 92 9.40 239 6.12 155 - 10.0 4.5 t-+- --. 4.50 920 500 3.81 I 5.75 3.63 9.40 ......- 6.25 18.0 100 3450 114.3 96.80 146 1 92 1 239 159 8.2 - TABLE CONTINUED On PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services D LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victauIic.Com \,tauIic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 REVN DIMENSIONS - NoMPA - ffi-811 =21, iii-00! WN " S .. I, FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N Size No. ~Presswe@ ID r165.1 lz~w ihrL MD UM gm om (im M ______TABLECONTINUEDFROMPAGE x 25 920¼ 4 1 500 150 i. 388 456 ii. _2. - I 3.79 9.34 96 237 2.75 1 8.0 70 3.6 - 1 1A 32 920¼ 500 1 1.75 3450 44.5 4.43 t 5.13 113 130 - 3.79 9.34 96 237 3.25 8.4 83 3.8 - - 1 ____. - - 500 2.00 0 50.8 4.41 5.13 1 12 0 1 ½ (a) to 40 920N 5.13 130 3.79 9.34 237 96 I 3.25 8.4 18 83 5.4 14 2 (a) t 50 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 500 2.75 -111 4 4.01 5.13 5.21 3.63 1 10.51 4.63 8.6 I 2.7 . 7.6 76.1 mm 920 3450 69.9 -±- 110 130 132 92 1 267 118 3.9 I 3.4 ____ 3(a) t o920 80 - --t------ 4.31 5.50 110 140 5.13 130 f 3.63 10.51 92 267 -L--t -- 5-.31 10.2 135 4.6 8.4 3.8 500 3.50 3450 88.9 - 5.38 -.. + - 3.63 10.51 --- 4- 6.25 10.5 . .- - 8.4 4 (a) to 920 500 4.50 3.81 5.75 100 3450 1143 .-..t -....--.- 500 I 2.75 97 146 5.44 6.19 137 6.25 .-.__+.,--. I 92 267 4.81 12.42 159 4.8 _--- 4.50 11.6 3.8 11.6 8 2(a) t 920 200 50 3450 69.9 138 157 159 I 6.19 , 122 316 114 , 5.3 j 5.3 2½ (a)t 2 500 2.75 5.07 6.19 4.81 12.42 4.50 j 11.6 11.6 65 °3450J69 129 157 J71224..316411 533 76.1 mm 920 500 2.75 3450 69.9 5.25 133 - 6.25 159 1 4.81 12.42 I 122 316 4.56 . 116 1 - 11.6 5.3 3(a) to 920 .----.---.-.--- 500 I 3.50 5.31 6.50 6.50 ---.-.-_.+ I 4.81 12.42 5.31 12.6 11.6 80 ..135 _165 165. ..... L...L.. 53 4(a) to 920 5001 4.50 4.81 6.75 6.38 4.81 1 12.42 6.25 15.3 12.5 100 3450 _114.3 122 171 162 122 1 316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com vlclAuuC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 VICTAIJLIC COMPANY. ALL RIGHTS RESERVED. REV_N \/'taUIiC 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for Cv ,K Values: AP = Q2 Where: - AP = Where: Q = Flow (GPM) - K 2 Q = Flow (m3/hr) 0= Pressure Drop (psi) v P = Pressure Drop (Bar) Q = C x C = Flow Coefficient Q = K, x JAT K = Flow Coefficient Exaggerated for clarity Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of O.165i014.2mm. 1 FireLocktm Innovative Groove System (IGS) outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. c 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. XACtsullie 11.026 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run size Outlet Lt j1p.Rated i Approval Agency Working Pressures - psi/kPa X JIirn F __ ______ 21/2-6 . 2.875 - 6.625 All ., 10,40 400 400 400 290 232 362 65-150 73.0-168.3 - 2.875 - 4.500 2755 300 -. -.- + 1 2755 300 2755 1 300 1999 290 1599 232 2496 21/2 - 4 All OF 362 65-100 73.O-1l41_ - - 2065 SF 300 - 2065 300 - 2065 300 1999 290 1599 - 232 2496 362 21/2-4 2.875 - 4.500 All 65-100 73.0-114.3 6.625 34 2065 10 300 2065 300 2065 250 1999 290 1599 232 2496 362 6 150 168.3 2065 2065 1724 1999 1599 2496 I 6 6.625 4 30 40 300 300 300 290 232 362 150 168.3 2065 2065 2065 t 1999 1599 2496 8 i 40 a625 21/2 400 I 200 219.1 8.625 1 34 2755 10 300 I — 250 — 1000 145 — 8 200 219.1 2065 j I 1724 1000 8 8.625 34 30,40 300 — 300 — 145 — 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. OF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 87100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems underpressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 57125mm, 6"/150mm and 87200 mm diameter pipe. The Style 931 comes with a 2W/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com \$'(taUIic vIcTAuuC Is A REGISTERED TRADEMARK OF vICTAuLIC COMPANY. O 2017 VICTALLIC COMPANY. ALL RIGHTS RESERVED. REVN 11.02_7 Mechanical-I® STYLES 920 AND 920N INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com \/taUIiC 11.02 148O REV N UPDATED 1212017 vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02.L Fire Lock® STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1114 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "L" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. Q 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G \4taulicr 10.521 DIMENSIONS IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 QD 1/. 1/2 1,i6 1 1.30 1.83 1.10 3.87 2.56 1.0 32 15 :2 4,33.0 46.5 j, 27.9 98.3 65.04. 0.45 1 3,4 1 3A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 -'--1'- 27.9 - 1----'-- 98.3 65.0 - -f r 0.50 1 11/6 1.52 2.18 -- 1.10 3.87 2.56 I - 1.2 25 30.2 1 3A6 38.6 1.42 --55.4 ---f- 1.95 27.9 -- 1.22 1 98.3 4.08 65.0 I + -+ 2.56 0.54 1.2 1½ 1/2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 4. 0.54 3/4 1/I6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 -- 35.6 49.5 j 31.0 103.6 j 65.0 4. 0.54 - 1 1 3A6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 1 /l6 41.7 1.66 58.4 2.19 31.0 1.46 103.6 4.60 65.0 2.56 0.59 1 1.3 2 ½ 50 x 15 30.2 1 42.2 55.6 37.1 116.8 65.0 0.59 'K 10 1.64 19 I L461 4.60 2.561 14 20 30.2 , 41.7 .....55.6 4. 373 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 1346 47.8 1,91 64.5 2.44 37.1 1.71 116.8 5.40 + 65.0 2.56 0.68 1.6 21/2 x ½ 65 15 30.2 48.5 62.0 43.4 137.2 65.0 4. 0.73 34 1,16 1.89 2.44 1.71 5.40 1 2.56 1.6 20 30.2 48..0 62.0 43.4 137.2 65.0 0.73 1 13/16 2.13 2.79 .. 1.71 5.40 2.56 1,6 25 1 3A6 54 L....._ 1.91 2.44 1.71 j137.2 5.50 65.0 2.56 0.73 1.6 761 mm x ½ 15 30.2 48.5 62.0 43.4 I 139.7 65.0 0.73 + ~ 1 3/16 1.89 2.44 1.71 ----f-....................E D 5.50 .., 2.56 1.6 20 30.2 4&0 62444L139J 65na73 1 13/16 ' 2.13 2.79 1.71 I 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com vICTAuLIC IS REGISTERED TRADEMARK OF VICTALILIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.522 %tauIicr REV_G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 Hazen-Williams coefficient of friction is 120 www.victaulic.com \Auctaulid VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVG 10.52_3 FireLock® STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 ictaulic vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 viciuic COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings Ductile Iron Threaded Fittings Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP @Ul Ductile iron castings conform to ASTM A536 LISTED Fitting dimensions conform to ASME B16.3 o Bushings and plugs conform to ASME B16.14 Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manulacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 530 500 150 200 480 25.0 460 300 440 350 420 400 400 380 450 500 360 550 600 340 - - 320 300 650 COUS APPROVED Fig. 35E3-90° Elbow LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E3012 1.75 25 50 0.8 1-1/2 35E 3014 35E 3020 1.94 18 10 36 1.1 2 2.25 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1x112 35RE3010004 1.26 1.36 70 1400.4 - 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 35RE3012006 1.34 1.53 35 70 0.5 1-1/4 x 3/4 1.45 1.63 35 70 60 0.6 0.7 1-1/4 x 1 35RE3012010 1.58 1.67 - 30 1-1/2x1/2 35RE3014004 35RE3014006 1.52 1.75 30 25 60 50 0.6 0.7 - 1-1/2 x3/4 1.52 1.75 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1!4 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 1.3 2x1-1/4 35RE3020012 1.90 2,10 12 24 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 -35RE3024014 2.16 2.51 6 - - 12 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 2.5 111 Fig. 35F3 -45° Elbow Size in Part N umber u A in Packing Weight lb Inner Master 1/2 3/4 35F 3004 - 35F 3006 - 0.88 150 300 0.2 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 1 20 1 40 1.0 2 35F 3020 1.69 10 20 - 1.6 2-1/2 35F3024 1.95 1 4 1 8 2.7 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3513004 1.13 80 160 0.3 3/4 3513006 1.31 30 60 0.5 1 3513010 1.50 25 50 0.7 1.1 1-1/4 35T3012 1.75 10 20 - 1-1/2 35T3014 1.94 10 20 1.5 2 3513020 2.25 6 12 2.4 2-1/2 3513024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwwsmithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x 1/2 - 35RT3006004 1.20 1.20 1.22 60 120 60 0.4 1 x 1/2 35RT3010004 1.26 _T_26 '773_6 30 -0.6 1x1/2x1 35R13010004010 1.50 1.36 1.50 30 60 0.6 1x3/4 35R13010006 1.38 1.38 1.45 25 50 0.6 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 0.7 1x3/4x1 35RT3010006010 1.50 1.45 1.50 25 50 1-1/4 x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35R13012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x1-1/4 35RT3012006012 1.75 1.62 T-75 -25- 40 1.0 1-1/4x1 35R13012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1x1/2 35R13012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x1x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x1x1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0- T1/2 _X1 12 35RT3014004 1.41 1,41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x 3/4 x1-1/4 35R13014006012 1.94 1.66 1.88 20 40 36 1.1 1.2 1-1/2x 3/4 x1-1/2 35RT3014006014 1.94 1.75 1.94 18 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 16 16 32 0.9 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 32 1.0 1-1/2xlx1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/4 35fIT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35RT3014012006 1.52 1.45 1.75 16 16 32 32 1.0 1.1 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 10 10 8 8 28 20 20 16 1.4 2x1/2 35RT3020004 1.49 1.49 ' 1.88 - 1.5 1.6 1.7 1.9 2x3/4 35RT3020006 1.60 1.60 1.97 2x1 2 x 1 x 2 35R13020010 1.73 1.73 2.02 35RT3020010020 2.25 2.02 2.25 16 2x1-1/4 35R13020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 216 8 8 16 16 2.0 21 2x1 1/2 35R13020014 202 202 2x1-112x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 - 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1 1/2x1 1/4 35RT3020014012 190 182 210 8 16 17 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 I C®uS <> APPROVED Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 35B13006010 1.45 1.45 1.37 30 20 60 40 0.6 0.9 1 x 1-1/4 35B13010012 1.67 1.67 1.58 1 x 1-1/2 35B13010014 1.80 1.80 1.65 15 30 1.0 1-1/4 x1x1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 10 30 20 1.3 1.6 1-1!4x2 35BT3012020 2.10 2.10 1.90 1-1/2x1-1/4x2 35B13014012020 2.16 2.10 2.02 10 8 20 1.8 1-1/2x2 35BT3014020 2.16 2.16 2.02 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.com 112 Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 -- 1-1/2 35CP3014 2.19 25 50 0.7 2 _35CP3020 - 2.62 15 - 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 NI Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35R03010004 - 1.69 80 160 0.3 - 1 x 3/4 35R03010006 - 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex)l 35RC3020010 2.81 20 40 1.0 Size in Part Number A in Packing Weight lb Inner Master lx 1/2 1x3/4 35HB3010004 1.06 180 360 0.2 351J83010006 1.06 180 360 0.1 1-1/4 x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2x1-l/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35SP3004 35SP3006 0.94 600 1200 700 0.07 0.1 1.12 350 1 35SP3010 1.25 200 400 - 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 o & 'VC42 0;0111, C&US APPROVED Fig. 35CP3 - Straight Coupling with Ribs LISTED Fig. 35RC3 - Hex Reducing Coupling Fig. 35HB3 - Hex Bushing Fig. 35U 3- Union with Brass Seat Size in a Number N mb A in Packing Weight lb Inner Master 1 351-13010 2.19 20 40 1.0 - 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.com Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 - 35C 3006 0.97 200 400 - 0.1 1 35C 3010 1.16 110 70 220 140 0.2 0.4 1-1/4 3503012 1.28 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 - Ream Clamp F'- I I Fig. 35X 3- Cross C(DUS <~> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X 3010 1.50 20 12 40 __ 0.9 1-1/4 35X 3012 1.75 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 Fig. 35RX3 - Reducing Cross I Size in I Part Number I I A I I in B i in Packing I Weight I lb I Inner I Master I 1-1/4x1 I 35RX3012010 I 1.67 I 1.58 15 I 30 I 1.2 I L±112X1I35RX3014010 1.80 1.65 11212411.41 2 x 1 35RX3020010 I 2.02 1.73 8 I 16 2.0 I Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner I Master 3/8 1/2 35B03003 35B03004 0.75 100 200 0.3 0.5 0.75 80 160 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.com 114 INSTALLATION STEPS -19M INTO WOOD & STEELT]KSULLATION STEPS - INTO WOOD &STEE Insert the appropriate nut driver into a 3/8' or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8"or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8', Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot tbs. for maximum pullout in purlin steel. INSTALLATION STEPS -!AUi1UNTO CONCRETE:j Using an SOS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pm-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill salon impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the 414 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or bolt stock (#I4SW red nut driver used with 1/2"screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - OJ I1i1b INTO CONCRETE: 1 I. Using an SOS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8' or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. HP.'IIii IlmulliiuF1ils SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. FOR WOOD \ SAMM 1' A Not less than 2' nominal wIdth Not less than 3" nominal thickness (2.1/2") (depth or side of vertical member) For erlica se - nsttface Minim emmbase A maleUa fo F A 3_compliance Wood Flooring 'No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. Mccurn Truss Cons II so an adorer or -- SI. fflagel ecom ended nsa at -doling ay be reqa 5 8 Tooa4gg_c cWatc ha video denionsirafion at www.itwbuildex.com #14 Black Nut Driver Part II 8113910 i . #14 SW Ned Nut Driver Part #8114910 1/4" 8002957 GST 100 1/4 x1" 25 125 r:J!L 8003957 GST200 1/4x2 -1-7-66-Fir- 25 125 114" 8004957 GST 300 1/4x3" 2060 (Fir) 25 125 - 3/8 8007957 GST 10 1/4 xl'670 300 25 125 3/8' 8008957 GST20 1/4x2" 1760 (Fir) 850 1475 25 125 3/8' 8068925 - GST 20-SS 1/4 x 2' - 1760 (Fir) - 850 - 25 - 125 JQL 3/8 8009925 GST 25-380 3/8x2 1/2 2113 (Fir) 1500 25 125 8_ 8010957 GST3O 114x3 2060(Fir) 1500 1475 25 - 125 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 - 3/8 8011925 040 1/4x4 2180 (Ar) 25 125 1/2" 8013925 GST2 1/4x2" 1760 (Fir) - 25 125 1/2 8014925 GST 25380 3/8 x 2 1/2 2113 (Fir) 25 125 1/2 8015925 GST3 1/4x3" 2275 (Fir) 25 125 (a . V SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Not less than 2' nominal width . (1-1/2") up to 3-1/7 pipe; not less than 3' (2-112") nominal width 4" & 5" pipe 4 I I Minimum 2-1/2" from bottom for branch lines. Minimum 3 from bot- tom for mainlines. Exception: This requirement shall not apply to 2" or thicker nailing ships resting on top of steel beams. 'I fl"1 -.____. ___-._- • No pre-drilling required. , tI • Quick to install using the Sammy Floor Joist -y I Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Made in the U.S.A. T.rr Ie a tch a iod, nsOalbn = v,ww.itwbulldex.com I I:r.]lM.]avM.gri11L'11 114" 8019957 SWG 200 1/4x2" 1725 (Fir) 25 125 It MG 16 622(Fir) 300 25 .125 8021957 SWG 20 1/4x2" 1725 (Fir) 1050 25 125 1 1- 8 073925 YQ2 S......1/4x2" 1725(Fh-) 850 25 125 IJEL 3/8" 8022925 SWG 25-380 3/8 a 2-1/2' 2249 (Fir) 1500 25 125 #14S Red LE 3/8 8023925 SWG30 1/4x3 1884 (Fir) 25 125 Nut Driver Part #8114910 May require pm-drilling. consult joist manufacturer. OOio4n ORRAFM Eliminates distortion of threaded rod. Accommodates up to 3%" x 12 pitch roof. Allows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. "Made in the U.S.A. #14 black I 3/8" 8139957 SH-GST2O 1/4x2 1257 (Fir) 1050 1475 25 1 , Nut Driver Part#8ll39lOt! 3/88141957 SHGST3O 1/4x3 1720(Ar) 1500 1475 25 1903 Dim. Lumber 1500 3/8" 8269957 St1-GST/CST 20 5/16 x 1-3/4' 1406 @ 45'off vertical 25 Dim. Lumber 903 Dim. Lumber 1/2' 8303957 SII-GST/CST 2.0 5/16 x 1-3/4" 1406 © 45'off vertical 25 Dim. Lumber May require pre-drilling; consult joist manufacturer. 125 125 125 #14 SH Orange Nut Driver Pan # 8273910 I-- APPROVALS I 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST2O 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST2O-SS 3/8" Vertical 2-1/2' 850 1-1/2" 8010957 GST3O 3/8" Vertical 4" 1500 1-1/2" 4 1475 1-1/2' 8009925 GST25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8' Horizontal 3-1/2"- 4" 1500 1-1/2' 8021957 SWG 20 3/8" Horizontal 2-1/2°-3°'° 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45° Angle off Vertical 2-1/2" 850 1-1/2° 8269957 SH-GST/CST2O 3/8" 45° Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17° Angle off Vertical 3' 1050 1-1/2" 4" 1475 1-1/2" IMEMO= IUtrtd11jffä 8038957 DSTR 11 3/8" Vertical 4" 1500 .035" 4" 1475 .105' 8037957 DSTR 1-1/2 3/8' Vertical 4° 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8' Vertical 4" 1500 .037" 4' 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188' 4" 1475 .188" 8046957 TEK5O 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8' Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8' Horizontal 4 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4' 1475 .060" 8137957 SH-DSTRI 3/8' 17° Angle off Vertical 4° 1500 .035" 4" 1475 .105" 8268957 Sl-I-TEK5O 318" Vertical 2-1/2" 850 70° Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2' 850 .027" 8153922 XP 35 8/8' Vertical 4" 1500 .060" 2 940 .029 4' , 1475 8294922 SXP 20 3/8" Vertical or up to 45° 2° 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical orupto89° 3-1/2' 1250 .060" 2" 635 .029' 8293957 SWXP 35 3/8" Horizontal 3-1/2" 1250 .060" SAMMYS FOR CONCRETE -PIPE hANGER 8059957 CST 20 3/8" Vertical 4' 1475 3000 8061957 SWC2O 3/8" Horizontal 4' 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC 35 PCF (lbs/fl3) 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP 20 3/8° Vertical 170 .027" 45° 80 .027' Vertical 250 .060" 8295922 SXP 35 3/8" 90° 80 .060' 8293957 SWXP 35 3/8° Horizontal 80 .060" 815022 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8150922 XP 35 3/8" Vertical 500 .060' Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8' Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT 86 trade sze RMC, iMC, and rigid PVC conduit 8293957 SWXP 35 We Horizontal 500 .060" Max 4 trade size EMT & 6 trade sze RMC, iMC, and rigid PVC conduit 8149957 CZ2000 1/4' or 3/8" Onto Vertical Rod UL Listed 4S16 -Cable Hanger, Cat No. C-Z2000 Plenum Rated, Complies w/ NEC Standards Sheet Steel IGauges Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 1/8" 3116" 114" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" 125' .188" .250" SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1t2' UI compliance with NEC Standards. SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL 1s4" UL and FM tests were performed in compliance with NFPA 13 Standards. °SWG 20 Maximum pipe size in composite wood joist allowed by UL 2-112' Fastening requirement 5 timeo weight of water-tilled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by ULwere tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037") cr20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030") or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offening. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite JoistlTruss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST 20 I .182" 1/8" GST 25-380 .280" 7/32" 1/8" I SWG 20 .182" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA!NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com ALSO LIDThD AS cOIIoOI DAIS CAnE MASAWARA MAAMICAWAFWALWJAIADAE Sm Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products MM 01 Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Fig. 25 - Surge Restrainer C® US LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 tolco. corn COOPER B-Line Component of State of California OSHPD Approved C@ us USTED Seismic Restraints System Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 98 - Rod Stiffener Size Range - Secures 3/8 thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electra-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE . CORONA, CA 92879' PH: 951.737.5599 . FAX: 951.737.0330 CUSTOMER SERVICE '800.186,5266 www.tolco.com Fig. 200_2112 to 200-8 Fig. 200 Fig. 200S Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. 8317ONF) ®TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170INFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - - keeps adjusting nut from separating with hanger. Hanger is easily / installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4' (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts - in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of - Fig. 200C Fig. 200F IMIl 200-1/2 1/2" (15) /8"-16 31/8 ' (79.4) 2I8" (66.7) 11 (5.0) 200-/4 3/4" (20) /8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) /8"-16 3I8" (85.7) 2/8" (66.7) 12 (5.5) 200_11/4 11/4 ' (32) /8"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) 2001112 11/2" (40) I8"-16 3/8" (98.4) 2/8' (73.0) 14 (6.4) 200-2 2° (50) I8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-2I2 21/2" (65) I8"-16 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 5/8" (149.1) 4" (101.6) 29 (13.3) 200_3112 31/2" (90) /8"-16 7 /8 (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7I8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) /2"13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2'..13 101/8" (257.2) 6I4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"_13 131/8" (333.4) 8I4" (222.2) 136 (62.3) All dimensions In charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200_2112 to 200-8 .... . 0 - • 0 Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily / installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) H to 200-2 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved /4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, 4.L. Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM OS 2-0. • . ;• .• 20011018-1/2 1/2" (15) M8 31/8" (79.4) 2I8" (66.7) 11 (5.0) 200M10-1/2 1/2" (15) MiO 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200M8-3/4 3/4" (20) M8 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4" (20) M10 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M8-1 1° (25) M8 3I8" (85.7) 2/8" (66.7) 12 (5.5) 200M1-1 1" (25) M10 3I8" (85.7) 2/8" (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-1114 11/4" (32) MiO 33/4" (94.0) 2/8" (73.0) 13 (5.9) 2001Y18-11/2 11/2" (40) MB 3/8" (98.4) 2I8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 3/8" (98.4) 2I8" (73.0) 14 (6.4) 2001Y18-2 211 (50) M8 4/2" (114.3) 3" (76.3) 15 (6.9) 200M10-2 211 (50) M10 41/2" (114.3) 3" (76.3) 15 (6.9) 200M-21/2 21/2" (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3° (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 7/8" (187.3) 51/4" (133.3) 34 (15,6) 200M-4 4° (100) M10 7I8" (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 611 (150) M12 101/8' (257.2) 6/4" (171.4) 73 (33.4) 200M-8 1 8° 1 (200) 1 M12 131/8" 1 (333.4) 1 8I4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are In millimeters unless otherwise specified I -5--- 1, • • COOPER B-Line ---- if oIijj;: IIi Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8"-16 or 1/2°_13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. J,. (B 200H-2-3/8 2" (50) /8"-16 4/16" (115.9) 3/32" (81.7) 48 (21.8) 20OIl-2-/2 2" (50) /2°-13 423/32 (119.8) 3/8" (85.7) 45 (20.4) 200H-21/2-3/8 21/2' (65) /8"-16 5/16" (134.9) 323/32 (94.4) 59 (26.7) 200H-21/2-1/2 21/2° (65) 1/2"13 515/32' (138.9) 3/8" (98.3) 56 (25.4) 200H-3-3/8 3° (75) I8"-16 53/4° (146.0) 327/32° (97.6) 63 (28.6) 200H-3-1/2 3° (75) 1/2"_13 5/8' (148.1) 331/32° (100.8) 60 (27.2) 200H-4-3/8 411 (100) /8'-16 6I8" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4° 1 (100) 1 1/2"13 71/32' (178.6) 419/32 (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8' pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line IE [b WOR - LJG11LI caM Description LubeFitO is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. :Th Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ° System Compatible Program* Certified to NSF/ANS/Std 61 -G Fost/1. SVSThM COMPATIBLE *FBCO System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 WW © 2012 Fire Protection Products, Inc. FPP!°, LubeFit5 are registered trademarks of Fire Protection Products, Inc. FGG/BM/CZ, Blaze-Master4', RowGuard GoleP and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.s.A. Fit® Th read Sealing Paste FP Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipef it® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FL3( SYSTEM COJAPATIBI.E *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. L .i 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1 800 344-1822 FAX + 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu © 2012 Fire Protection Products, Inc. FPPIA, LubeFif5 are registered trademarks of Fire Protection Products, Inc. FHC', HIazeMaster, FlowGuard Gold" and Corzana are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. IN, =e-a-d F ol- T aff 1 @1 R ,00 =,e_adtCt7Uft1jE ",~SMITI ok Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. r 1 ThredFir wu © 2013 Fire Protection Products, Inc. FPP!5, ThreadFit are registered trademarks of Fire Protection Products, Inc. MADE IN U.S.A. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke [F[ SYSTEM COMPATIBLE *FBC" System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMastere, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300. Fir D1)sPFAris Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings.