HomeMy WebLinkAbout2504 MARRON RD; ; FPR2019-0099; Permit(city of Carlsbad Print Date: 12/14/2021 Job Address: 2504 MARRON RD, CARLSBAD, CA 92010-8312 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 1670307800 Track #: Valuation: $000 Lot # Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check # Permit No: FPR2019-0099 Status: Closed - Finaled Multifamily Fire Alarm Applied: 04/29/2019 Issued: 05/31/2019 Finaled Close Out: 12/14/2020 Inspector: Final Inspection: Project Title: Description: MARBELLA APTS LEASING & REC BLDG -REPLACE OF FIRE ALARM CONTROL PANEL Applicant: FPContractor: COMMERCIAL FIRE PROTECTION COMMERCIAL FIRE PROTECTION INC JOE ORTEGA 4340 VON KARMAN AVE, # 300 360 GODDARD NEWPORT BEACH, CA 92660-2004 IRVINE, CA 92618-4601 (949) 415-2653 (714) 417-5788 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Duet $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov WWARDS Cataiog Small Building Fire alarm Solutions F~ F~ F~ IM 0 " FPR20I9-0099 2504 MARRON RD H I iI FlY INCItHENI MANfr\flLMI Ni MARBELLAAPTS LEASING &REC BLDG REPLACE OF FIRE ALARM CONTROL PANEL Intelligent Fire Alarm Systems 1064, 101000 FPR20I9-0114 2504 MARRON RD MARBELLA APTS BLDGS 1-13 - REPLACE OF FIRE ALARM CONTROL PANEL 1670307800 5/3012019 FPR20I9-0114 Overview EDWARDS brand intelligent life safety systems offer the power of high-end intelligent processing in configurations that deliver uncomplicated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily- configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The i064 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NAGs). Optional Class A device wiring is available with the use of a module. The 101000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The iO1000 panel includes four NACs that may be wired for either Class A or Class B operation. The RZI16-2 module adds even more capacity to iO installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them an ideal retrofit solution that can accommodate new intelligent detectors, as well as existing conventional devices. iO Series supports a wide range of high-end features, including: Signature Series intelligent modules, detectors, and bases A-Series remote annunciators SIGA-REL Releasing Modules Fully integrated CO detection using Signature Series detec- tors with or without audible signaling 1670307800 5/2412019 FPR20I9-0099 Features Auto-programming speeds installation time Supports Signature Series intelligent modules and detectors Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Alarm ON command manually activates alarm condition FDNY COA 6227 I 7165-1657: 0244 S3000 Page 1 of 8 DATA SHEET E85001-0135 Not to be used for instaliatiori purposes Issue 1.3 Application EDWARDS iO Series life safety systems are powerful intelligent solu- tions for small to mid-sized buildings. Advanced intelligent technol- ogy delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Signature Series electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Mean- while, innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Addressable Technology boosts the reliability of EDWARDS fire alarm systems. When combined with iO Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All EDWARDS systems are built to exacting reliability benchmarks. Clear-cut remote annunciation Remote annunciation is a strong suit of the iO Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. iO control panels also supports graphic annunciation with optional RA Graphic Annunciator interface mod- ules. Each interface provides common control and 32 LEDs. Flexibility built right in Two fully-programmable front panel switch/LED combinations provide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Programming and remote diagnostics EDWARDS iO Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, iO Series systems interface to a PC running com- patible iO-CU software. This option offers full system configuration in the familiar Windows® operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of iO Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to download to the panel from the iO-CU, or upload and view system reports using the 0-CU. Available system reports include: Correlation groups, Device de- tails, Device maintenance, History, Internal status, System configu- ration, System status, Walk test, Dialer, and CO runtime. Perfect for retrofits EDWARDS iO Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to iO technology without the expense or disruption of rewiring the en- tire building. iO control panels also support the ingenious RZl1 6-2 Zone Module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intelligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Scalable lP and Cellular Communications Several popular third-party IP/Cellular communicators have been tested with the iO control panels and are compatibility listed to UL864. The lP/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/ Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the iO control panel compat- ibility documentation part number 3102353-EN for a full list of compatible communicators. Signals with a difference iO system NACs are configurable to fully support the advanced signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances. These devices offer precision synchro- nization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. A complete line of accessories iO Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions (2) (3) (4) - D7 To 1;i o o 10 o o o D4 08 01 o 10 o 1' D9 D9II Surface Mounting Holes (3) Backbox with Door Attached Semi-flush mounting Holes (4) Backbox with door and trim kit attached. Panel dimensions, in (cm) Model D1* D2 D3 I D4 I 05* D6 I D7 I D8 28.0 j 3.85 I 9.0 I D )7l.l) I0.25 I 28.2 2.7 01000 I (98) I (22.8) IE22.0E O. 1 (26.0) (11.1) (71.6) i (6.8) 21.5 3.85 7.5 10.25 I 4.5 I 21.7 I 2.7 064 (54.6) (9.8) (19.0) I (26.0) (11.4) (55.1) (6.8) *Add 1-1/2 in. (3.81 cm) to D1 and 05 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. Page 2 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes Issue 1.3 Sixteen Conventional lDCs, , two additional NACs with RZI1 6-2 module System Layout 101000 Any combination of two single- or dual Signature loop modules - Standard Loop: 250 points (one expansion slot) -'-'- 10-SDC2 Expander, Loop 1 of 2: 250 points Up to 125 sensors and 125 modules per loop i0-SDC1 Expander Loop: 250 points (one expansion slot) I (one expansion slot) I iO-SDC2 Expander, Loop 2 of 2: 250 points Up-to- 20,000 feet of wiring per loop W Four Class "B or two optional Class A NACs Optional 10 A or 6.5 A Booster Ethernet (SA-ETH) DACTSDA RS-232 (SA-232)!4rF~ Relays: Two Form C, one Form A Each iO1000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. 01000 loops support 125 detectors and 125 modules. i064 11111- \ Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring. Two Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Power Supply F tC, PQt emote /jrrJnca OTo Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each i064 panel ships with one Signature loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. Panel Layout H iJZIU 0 IIUiI 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (Ji) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries Page 3 of 8 DATA SHEET E85001-0135 Not to be used for install ation purposes. Issue 1.3 Class A wiring Data Lin. Class B wiring Data Line Loop Loop Loop card device device Class A Channel 1 Channel 2 Class B Channel I Channel 2 DLR DLR Class B wiring Class A wiring Annunciator CHI IN )CHI I-) IN CH2 (+) IN CH2 t-t IN Annunciator ) CHI (+) IN CHI IN CH2 t) IN CH2 f-I IN DATA SHEET E85001-0135 Not to be used tot Installation purposes. Issue 1.3 Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. Page 4 of 8 Wiring & Configuration Signature device loop The system provides one Signature device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit i01000 i064 specifications Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20 V peak-to-peak line voltage Circuit current 0.5 A max Circuit 660 total, 0.5 jF, max impedance Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using a SlGA-CC1 S or SIGA-MCC1 S module and Genesis or Enhanced Integrity notification ap- pliances. Notification appliance circuits (TB2) iOl 000 control panels come equipped with four notification ap- pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications i01000 i064 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage 24 VFWR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 26 0 total, 0.35 ik max EOLR 15K0,1/2 W Synchronization Supported system-wide Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two wire smoke detectors. Aux 2 can be software selected to operate continuously. The circuit is supervised for shorts and grounds. Circuit specifications Circuit voltage 21.9 to 28.3 V range Resettable circuit 24 VDC nominal at 500 mA (Aux power 2) Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two-wire smoke detectors. Note: Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAG power by that amount. (1) Trouble Alarm, trouble, and supervisory relay (TB3) (2) Supervisory The trouble relay is normally-open, held closed, (3) Alarm and opens on any trouble event or when the panel is de-energized. The supervisory relay is (4) Smoke/Aux normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Alarm ] Trouble Supervisory Type Form C Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style 'v') or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Option Cards EDWARDS iO Series panels are supported by a complete line of modules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet provides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with the 1064 as a replacement for the standard 64-point loop, or with the 101000 as a 250-point expansion module. The iO-SDC2 is a 500-point dual loop controller card for the iOl 000 that provides two SLC circuits, each with 125 detector addresses and 125 module addresses. Specifications i0-SDC1 iO-SDC2 Device Addresses iOl 000: one loop, 250 device addresses i064: 64 addresses 01 000: two loops, 500 device addresses Wiring Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Alarm: 80 mA Standby: 45 mA Alarm: 70 mA Note: These ratings do not include the use of two-wire smoke modules. Communication Line Max. 20.6 V peak-to-peak Voltage Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current 0.5 A max. Max total loop 66 0 resistance Max total loop 0.5 pF capacitance Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0 to 5 k) Impedance Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card SA-ETH wiring The SA-ETH card provides a To networic connection standard 10/100 Base T Ether- net network connection for Network cable connecting to an intranet, a local network, or the Internet. The card can be used to download configuration programming from 13 the iO-CU to the panel. The Ethernet card is installed on the plastic assembly and con- Ethernet card nects to the main circuit board via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base T environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F RZI16-2 Remote Zone Interface Module 60— J . I_'_ The RZI1 6-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZI1 6-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZ116-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA! circuit Standby current for 3.9 k EOL (Canada) 5.7 mA! circuit Alarm current at nominal voltage 31.1 mA! circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kO (U.S.); 3.9 kO Canada Zone voltage 22.78 V for 4.7 kO (U.S.) 22.08 V for 3.9 kO (Canada) Alarm current 31.1 mA' channel at nominal voltage Alarm impedance range <680 0 Trouble impedance range > 5.55 kO Supervised output circuits EOL resistor 15 kO Quantity 2 Short circuit detection <2.6 kO Open circuit detection > 61.9 kO Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), 01000, APS Page 5 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the iO-CU. SA-DACT Phone line wiring To wall Phone line 1 phone jack Phone cables (supplied) jacks The dialer phone lines connect to connectors on the dialer's main circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector J1. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-DACT specifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31/38X) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBll CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch 06600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact (0 SA-232 RS-232 interface The SA-232 card provides an RS-232 in- SA-232 wiring ______ GND (black wire) terface with 0 panels. It can be used for TXD (white wire( connecting a printer to the control panel R.XD (red wire) to print system events. The card also wcan be used for connecting a computer to download a configuration program I 0 from the iO-CU to the control panel. fl fl The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard EIA-232 Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (i064 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with i064 control panels only. iO1000 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VFWR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) D16L-10 LED Display Expander (101000 only) The Dl 6L-iO LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone. Two D16L-iO LED display expanders can be installed in each iO1 000 panel. () (4) LED 1 LED 2 LED Expander 1 LED Expander 2 Alarm/non-alarm and trouble zone LEDs Page 6 of 8 DATA SHEET E85001-0135 Not to be used for installation put poses Issue 1.3 Specifications i064 101000 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (125 modules) detectors and 125 modules max.). Addresses 1 to 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B (Style Y), Class A (Style Z) optional 4 Class B (Style Y) or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC circuit Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the 1064 and iO 1000 Series Compatibility List (P/N 3102353-EN) Loop circuit Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 pF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/1 15 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the i064 control panel cabinet and two 18 Ah batteries will fit in the iO1 000 control panel cabinet. If larger batteries are required, use an EDWARDS battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38X) Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 kO Alarm contact Form C N.C. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.O. 24 VDC at 1 A (resistive load) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) Page 7of8 DATA SHEET E850010135 Not to be used for installation purposes Issue 1.3 Ordering Information Part Description i01000 Fire Alarm Systems 101 000G Four loop system with one 250-point loop installed. 110v, gray door. LIFE SAFETY & INCIDENT MANAGEMENT 101 000G-2 Four loop system with one 250-point loop installed. 230v, gray door. Contact us... 101000G2PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. Email: edwards.fire@fs.utc.com I010000-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. Web: edwards-f/re.corn I01000G-CA Four loop system, one 250-point loop installed. 110v, gray door, LED strips, Canada. 101000GD Four loop system, one 250-point loop installed. 110v, gray door, with dialer. 1016 Corporate Park Drive 101 000G-F Four loop system, one 250-point loop. 110v, gray door, LED strips, French Canada. Mebane, INC 27302 101 000G-PG Four loop system with one 250-point loop installed. 110v, gray door, Portuguese. EDWARDS is a registered mark in the 101000G-SP Four loop system with one 250-point loop installed. 110v, gray door, Spanish. United States and other countries. 101 000R Four loop system with one 250-point loop installed. 110v, red door. © 2018 United Technologies Corporation. 101000R-2 Four loop system with one 250-point loop installed. 230v, red door. All rights reserved 101 000RD Four loop system, one 250-point loop installed. 110v, red door, with dialer. SA-1R1M2 iOl000 Flush mount trim, black. i064 Fire Alarm Systems 1064G One loop system with one 64-point loop installed. 110v, gray door. 10640-2 One loop system with one 64-point loop installed. 230v, gray door. 1064G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. 10640-2-SP One loop system with one 64-point loop installed. 230v, gray door, Spanish. 10640D One loop system, one 64-point loop installed. 110v, gray door, with dialer. 10640L One loop system, one 64-point loop installed. 110v, gray door, English Canada. 10640L-F One loop system, one 64-point loop installed. 1 10v, gray door, French Canada. 1064G-PG One loop system with one 64-point loop installed. 1 10v, gray door, Portuguese. 1064G-SP One loop system with one 64-point loop installed. 110v, gray door, Spanish. 1064R One loop system with one 64-point loop installed. 110v, red door. 1064R-2 One loop system with one 64-point loop installed. 230v, red door. 1064RD One loop system, one 64-point loop installed. 1 10v, red door, with dialer. SA-TRIM1 i064 Flush mount trim, black Option Cards iO-SDC1 Expansion module, one 250-device loop. iO-SDC2 Expansion module, two 250-device loops, 500 devices total. For i01000 only RZI 16-2 Remote Zone Interface Module. 16 Class B lDCs, 2 Class B Output. Includes bracket. SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. i064 systems only. D16L-iO-2 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. For iOi ODD only. D16L-i0-1 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. For iOi 000 only. D8RY-0-2 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For 01000 only. D8RY-i0-1 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iO1000 only. Accessories CTM City Tie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8" x 14" x 3.5" - red. SIGA-REL Releasing Module PT-is System Printer BC-1 Battery Cabinet. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-1 R Battery Cabinet - Red. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-1 EQ Seismic hardening Kit for iO series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools 0-CU 10 Series configuration and diagnostics utility. 260097 R5232 cable, 4 conductor. DB9 PC interface Page 8 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.3 MS-4(E) Fire Alarm Control Panel General The Fire-Lite MS-4 and MS-4E Fire Alarm Control Panels (FACPs) bring the latest in microprocessor technology to con- ventional fire controls. The MS-4 is compatible with the j3TM smoke detectors from System Sensor, with drift compensation, maintenance alert, and freeze warning. Automatic synchroniza- tion of audio/visual devices with three selections for manufac- turer protocol. The Notification Appliance Circuit (NAC) protocol can silence audible devices while strobes continue to flash, using a single pair of wires. The MS-4 is compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterf low devices, tamper switches and other normally-open contact devices. Refer to the Fire•Lite Device Compatibility Document for a complete list of compatible devices. Note: Unless indicated otherwise, the term "MS-4" refers to both MS-4 and MS-4E models. Features Four Style B (Class B) Initiating Device Circuits (lDCs). Two Style Y (Class B) NACs. Optional module that converts all four lDCs and two NACs to Class A operation. 24VDC. j3TM Technology features: - Drift compensation automatically adjusts detector sensitiv- ity and increases resistance to false alarms caused by dust accumulation. - Maintenance Alert LEDs (per zone) warn of excessive dirt accumulation, preventing false alarms (meets NFPA 72 requirements). - Detector sensitivity is automatically measured by the detector, which automatically adjusts its sensitivity back to the factory settings when it becomes more sensitive due to contaminants settling in the chamber. - Wireless handheld sensitivity meter eliminates the need for voltmeters, magnets, and a physical connection to the detector. The reader displays sensitivity in terms of percent per foot obscuration and provides text status indication. - Supervisory LED (per zone) provides warning if a detector senses temperature approaching freezing. - Special test protocol and LED indication allows quick test of all detectors without need for a ladder. NAC synchronization features: - Synchronization of standard ANSI audible signals as required by NFPA 72. - Synchronization of ADA compliant strobes per NFPA 72. - Selectable for System Sensor, Wheelock, and Gentex protocols. - Selective Silence feature for manual silence of horns while strobes continue to flash on the same NAC. - Alarm verification selectable for each zone. - Disable switches provided per zone. NACs programmable for: - Silence Inhibit - Auto Silence - Strobe Synchronization - Selective Silence (horn-strobe mute) - Temporal or Steady signal - Silenceable or Nonsilenceable DF-52266:132 • A2-260 8 Fire LITALS by Honeywell Silent or audible Walk Test operation mode commanded from the front keypad, with automatic return-to-normal after one hour of inactivity. Each zone may be programmed for supervisory or fire; each zone has separate red and yellow LEDs. Zone 4 is programmable for combination of tamper supervi- sory monitoring and waterflow alarm. Form-C Alarm, Trouble, and Supervisory relays. 3.0 A total usable current. 6.0 A total usable current available with optional second transformer. Control buttons: - ACK (Acknowledge) - Alarm Silence - Reset - Walk Test - Zone Enable/Disable (one per zone) LED indicators: - Fire Alarm (one per zone) - Supervisory (one per zone) - Trouble (one per zone) - Maintenance (one per zone) - AC Power - NAC Disable - Zone Disable - NAC Fault - System Trouble - Power Trouble - Walk Test - Alarm Silence - Earth Fault (on circuit board) - Battery Fault (on circuit board) - Charger Fault (on circuit board) Piezo sounder for alarm, trouble, supervisory and mainte- nance. Optional plug-in 4XTMF transmitter module. Optional plug-in 4XZMF zone relay module. Optional 4XLMF transmitter module for RZA-4XF remote LED annunciator. Optional dress panel. DF-52266:B2 • 12/21/2012 - Page 1 of 2 Operation Activation of a compatible smoke detector or any normally-open fire alarm initiating device activates audible and visual signaling devices, illuminates an indicating LED, sounds the piezo sounder at the FACP, activates the FACP alarm relay and oper- ates an optional module used to notify a remote station or initi- ate an auxiliary control function. Specifications AC POWER - T83 MS-4: 120 VAC, 50/60 Hz, 2.3 A. MS-4E: 240 VAC, 50Hz, 1.15 A. Wire Size: Minimum 14 AWG (2.0 mm2) with 600 V insulation. BATTERY (SEALED LEAD-ACID ONLY) - J8 Maximum charging circuit: normal flat charge 27.6 VCD @ 0.8 A. Maximum battery charger capacity: 18.0 AH battery (two 7.0 AH batteries can be housed in the FACP cabinet. Larger batteries require a separate battery box such as the Fire-Lite BB-17F). INITIATING DEVICE CIRCUITS - T83 Alarm zones 1 - 4. Power-limited circuitry. Operation: all zones Style B (Class B). Normal operating voltage: nominal 20 VDC. Alarm current: 15 mA minimum. Short-circuit current: 40 mA maximum. Maximum loop resistance: 100 ohms. End-of-line resistor: 4.7K ohm, 1/2 watt (P/N 71252). Standby current: 4 mA. Compatible devices: refer to the Fire•Lite Device Compatibil- ity Document PN 15384 for a complete list of compatible devices. NOTIFICATION APPLIANCE CIRCUITS - T62 Two NACs. Power-limited circuitry. Normal operating voltage: nominal 24 VDC. Maximum signalling current: 2.5 A total with standard trans- former 5.0 A total (2.5 A maximum per NAC) with optional transformer. End-of-line resistor: 4.7K ohm, ½ watt (P/N 71252). Compatible devices: refer to the Fire•Lite Device Compatibil- ity Document PN 15384 for a complete list of compatible devices. FORM-C RELAYS Trouble Relay TB5 (fail-safe). Alarm Relay TB6. Supervisory relay TB7. Relay contact ratings: 2.0 A @ 30 VDC (resistive). AUXILIARY OUTPUT: RESETTABLE POWER - T81 Operating voltage: nominal 24 VDC. Maximum available current: 500 mA - appropriate for pow- ering four-wire smoke detectors (see notes). Power-limited circuitry. Notes: 1) Refer to the Fire-Lite Device Compatibility Document for a complete list of compatible devices. 2) Total current for nonresettable power, resettable power and two NAGs must not exceed 6.0 A for the MS-4 (required optional second transformer). CABINET DIMENSIONS Door: 15.342" (38.97 cm) high x 14.667" (37.28 cm) wide x 0.375" (0.95 cm) deep. Backbox: 15.0" (38.10 cm) high x 14.5" (36.83 cm) wide x 3.0" (7.62 cm) deep. BA CKB OX MOUNTING The cabinet can be surface mounted. The door is removable during installation by opening and lifting it off the hinges. The cabinet mounts using two key slots at the top of the backbox and two additional 0.25" diameter holes at the bottom. Listings and Approvals UL Listed: S624 MEA: 297-01-E CSFM: 7165-0075:200 Ordering Information MS-4: Four-zone conventional FACP; 120 VAC, 50/60 Hz, 2.3 A. MS-4E: Same as above, but 240 VAC, 50 Hz, 1.15 A operation. CAC-4: Class A converter module. Used to convert Style B (Class B) lDC to Style D (Class A) and Style V (Class B) NAC to Style Z (Class A). The module connects to J1 on the MS-4 cir- cuit board. 4XTMF: Transmitter module. 4XLMF: LED interface module. 4XZMF: Zone relay module, 4 form C relay. RZA:-4XF: Remote Annunciator. BB-17F: Battery box, required to house two batteries greater than 7 AH to a maximum of 18 AH. 411/411UD: Three-input (channels) model 411, and four-input model 411 UD, dual-line Digital Alarm Communicator/Transmit- ters (DACT5). Can be used as slave communicators with the FACP. DP-MS2/4: Optional dress panel. MS-4RB: Replacement board. TR-1-R: Optional trim ring for semi-flush mounting. A 2-zone version of this panel is also available. See DF-52211. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. y • p _ast' - ,, -- - . - - - - ,-: " - 'z . -'t .. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. LNGINEIIIINC A MANFACHNIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2- DF-52266:132 • 12/21/2012 Cwards Signaling R-Series Remote Annunciators E-RLCD, E-RLCD-C, E-RLED-C, RLED24, GCI Edwards Signatng cataog 1> Annunciation 100 1 0 Im" flL!JEJ Overview Edwards R-Series Annunciators are high-performance remote annunciators that provide status indication and common controls for compatible fire alarm control panels, including E-FSA-Series small analog fire alarm systems. This family of annunciators offers LCD or LED annunciation. Models are available with and without common controls. There are three R-Series annunciator models, plus an LED-based expander. Up to two expanders can be connected to any annun- ciator. The expander includes 24 pairs of LEDs that extend the capabilities of any of the annunciators. All annunciator models include status LEDs and an internal buzzer. Two models have an LCD text display, and one has 16 pairs of LEDs for zone annunciation. LCD models feature a large back-lit, four by twenty character per line, super-twist liquid crystal display. R-Series annunciators and expanders are mounted on a standard 4-inch square electrical box, using the included mounting ring. They can also be surface mounted in locking steel enclosures. Three different enclosures are available. A keyswitch and graphic annunciator interface is available for R-Series annunciator applications. The keyswitch enables or dis- ables common controls. The graphic annunicator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Features LCD models feature large 4 x 20 character backlit LCD display LED models provide 16 pairs of LEDs for zone annunciation Available expander extends capability with 24 pairs of LEDs Up to two expanders may be wired to each annunciator Status LEDs and internal buzzer standard on all models Common controls available for LED and LCD display models Available keyswitch for disabling common controls Standard 4-inch square electrical box mounting Class B or Class A RS485 wiring standard One-, two-, and three-position enclosures available Graphic Annunciator interface, includes common control, indi- cators and 32 LEDS No programing required, set the address and unit recieves all information from panel Page 1 of 4 DATA SHEET S85005-0128 Not to be used for installation purposes. Issue 2 o o o o g o[— go o o o L— -— Jeoa gL MEN / N igEi : lo l Z o o oo o CHI OUT RLCD Features by model E-RLCD E-RLCD-C RLEOZS E-FILED-C RLED24 Reset a' V V - Ack/Silence V Fire Alarm Supervisory V V V - Ground Fault Trouble V Controls Enabled Ack/Silence Reset Signal Silence Drill Lamp Test V V V - LCD Display V V - - Zone Active LEDs - - 16 * 24 " Zone Trouble LEDs - - 16 24 Graphic Annunicator Interface The GCI Graphic Annunciator Driver is an interface card that Remote Keyswitch connects the fire alarm control panel to the display panel of an LED-based graphic annunciator. Annunciator LSRA-RK The annunciator card supports 32 LEDs and 16 switches on the KEYSWITCH graphic panel display. It Includes status LEDs and an internal KEYSWITCH U (0) 0 0 buzzer. The graphic interface is supplied with snap track mounting. It is Keyswitch Specifications attached to a plastic mounting rail that requires two EIA panels. Maximum 5 Vdc voltage The annunciator communicates with the FACP on the R5485 Maximum 200 mA data riser. This can be configured for Class A or Class B commu- current nication. The annunciator does not provide ground fault isolation. Mounting 2-1/2 in (64 mm) It is a stand-alone unit that can be powered by the FACP or by an deep 1-gang box approved power supply. Termination Screw terminals Maximum 12 AWG Graphic Annunciator Interface Specifications wire size (2.5 mm sq) Alarm current 146 mA at 24 Vdc (with 36 LEDs ON) Contact Normally open Standb current 'F mA at 9/1 \/r)c (inoth no LEDs ON) crarifiani -ration 09 Application Annunciator Wiring A-Series annunciators communicate with the FACP on the RS-485 Annunciator, Class A data riser. This can be configured for Class A or Class B commu- nication. Annunciators do not provide ground fault isolation. RS-485 CHI (0) IN -Ø These annunciators are stand-alone units that can be powered by CHI (-) IN CH1 +)OUT the FACP or by an approved power supply. CHI (—(OUT -.0 CH2 (-) IN LISTED 24 V CH2 OUT (°1 SUPPLY CH2 (—I OUT 24V IN 24 VOC + -121 l°l -Ø 24v IN 24 VOC - 24v (l OUT 241/ OUT - GROUND Annunciator -0 CHI () IN -0 CHI (—(IN 0 CHI 1°) OUT 0 CHI (—)OUT -0 CH2 (a) IN -Ø CH2 IN O CH2 (+( OUT 0 CH2 (-I OUT -0 24V (a) IN -0 241/ IN 0 241/ (l OUT 0 24v OUT --n GROUND RLCD-C BLED-C Annunciator, Class B FACP Annunciator Annunciator RS-485 LCH1 ) IN -0 Clii (a) IN OUT OUT I E 0 CH2 (0) IN 0 CH2 (a) IN ØCH2(—(IN Ø CH2 (—(IN LISTED 24 0 CH2 (a) OUT 0 CH2 (a) OUT SUPPLY 0 CH2 (—) OUT 0 CH2 (—(OUT 24V0C * 0 24V (a) IN 0 24V (a) IN 241/DC— 024V(—(IN 24V IN 24v (+) OUT 0 241/ (*( OUT 24v (-( OUT 0 24V (—( OUT 0 GROUND 0 GROUND Expander --------------------- Annunciator Fcrst Expander Second Expander OUT IN OUT IN OUT v(_(04 V(—( V(—(Ø ------------ -ØV( — ( V(—(Ø V(e(O_L V(+( v(+(Ø ------------ -ØV(*( V(+(Ø FØ- F F & ----------H-- OF F® Ø- E E EØ ----------H - OE EØ Ø DØ- D D ----------- O D DØ e - C®- C C - ----------- - Ø C C® 80- B BØ ------------ B B® zones 13-16 may be selected as Supervisory on E-FSA64 A Øe A A 0 --------------0 A A 0 ** zones 13-16 and 29-32 may be selected as Supervisory on E-FSA250 ,--.-- .........-------, ~j Ile Maximum current 10 mA per LED Page 2 of 4 DATA SHEET S85005-0128 Not to be used for installation purposes Issue 2 Annunciator Connections Annunciator DIP switch settings Switch Description and values Si to S5 The annunciator network address (in binary). Network The factory setting is for address 2. address Examples: 10000 = 1 01000 = 2 11000 = 3 00100 = 4 S6 Network OFF = 9600 baud (factory default setting) baud rate ON = 36,400 baud S7 to S8 Not used Annunciator Mounting jr9 EXPANDER CABLE 0 0 o MOUNTING RING EXPANDER ELECTRICAL BOX Mounting slot DIP switch RS-485 riser terminals Power terminals Communication LEDs Expander Mounting slot Expander cable terminals Remote keyswitch terminals Expander cable terminals Expander cable terminals Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure, surface mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover, and key lock. The enclosures are 16-gauge welded steel with a white, painted finish. Each enclosure includes a security lock and two keys. The two- and three-position enclosures have wiring channels for cor- rect routing of interconnections. The enclosures attach to a standard electrical box, and provide a mounting lip that takes the place of the integral mounting ring sup- plied with the annunciators and expanders. =1 - ) rr 00000 RA-ENC1 6.0 in 15.2 cm H 0.9 in 2.3 cr RA-ENC3 in ' 9.5 I 24.1cm II I I 2.0 in 9.8 in l l Jj 5.1 cm 24.9 cm I Dimensions (H x W x D) RA-ENC1 6.3 x 9.8 x 2.0 in (16.0 x 24.9 x 5.1 cm) RA-ENC2 12.0 x 9.8 x 2.0 in (30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in (45.0 x 24.9 x 5.1 cm) Note: Allow approximately 2 inches (50 cm) clearance on both sides of the enclosure, to permit inserting and removing the key, and opening the door through 90 degrees. RA-ENC2 Page 3 of 4 DATA SHEET S85005-0128 Not to be used for installation purposes, Issue 2 Specifications E-RLCD-C E-RLCD E-RLED-C RLED24 Operating voltage 24 VDC, continuous. Standby current 99 mA 98 mA 28 mA 6 mA Contact us... Alarm current 115 mA 113 mA 62 mA 34 mA Phone: 1-800-336-4206 Web: www.edwardssignaIing.com RS-485 communications Class A or Class B, 9600 baud Edwards Signaling is Data wiring 18 to 14 AWG (1.0 to 2.5 sq mm) twisted pair (6 twists per foot an EDWARDS brand, minimum). Maximum wire run is 4,000 ft. (1,219 m) 3 Farm Glen Boulevard Remote key switch circuit 5 VDC at 1 mA, power-limited, unsupervised Farmington, CT 06032 Ground fault impedance 0 In Canada, contact Chubb Edwards... Power wiring 18 to 14 AWG (1.0 to 2.5 sq. mm) Email: inquiries@chubbedwards.com Display area 4 lines of 20 characters each Web: www.chubbedwards.com Dimensions (H x x D) 5-5/8 x 8-1/2 x 1-1/2 in. (14.3 x 21.4 x 3.8 cm) © 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Mounting North American 4-inch square electrical box or listed enclosure Specifications subject to change Agency Listing UL, ULC without notice. Edwards is part of UTC Climate, Controls & Security, a unit of Operating environment Temperature: 32 to 120°F (0 to 49°C) Humidity: 0 to 93% RH, United Technologies Corporation. noncondensing at 90°F (32°C) Ordering Information Part Description Remote Annunciators E-RLCD LCD text annunciator without common controls. English. E-RLCD-C LCD text annunciator with common controls. English. E-RLED-C 16-pair LED zone annunciator with common controls. English. Remote Expanders RLED24 24-pair LED zone expander with expander cable and zone card insert. Enclosures RA-ENC1 One-position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-SB Surface Mount Box - for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver, provides outputs for common indicators and 32 alarm/ supv zones as well as inputs for common switches. Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling or disabling common controls (Lock! 27193-16 Electrical box, surface mount, white, single-gang, for RKEY. Page 4 of 4 DATA SHEET S85005-0128 Not to be used for installation purposes Issue 2 EDWARDS Catalog Intelligent Input/Output AS nitedTecnoogio JY Nl[)FNT MNA(I JvlE NJ Signal Modules SIGA-CC1, SIGA-MCC1. SIGA-CC2 & SIGA-MCC2 '1 Tii -- I -- - - r -i m SIGA-CC MEA 9 7300-1657:1 0121 I S3424 SIGA•MCC Overview SIGA-CC1/MCC1 Single Input Signal Modules and SIGA-CC2/ MCC2 Dual Input Signal Modules are part of EDWARDS's Signa- ture Series system. They are intelligent analog addressable devic- es used for connecting, upon command from the loop controller, supervised Class B signal or telephone circuits to their respective power inputs. The power inputs may be polarized 24 Vdc to oper- ate audible and visible signal appliances or 25 and 70 VRMS to operate audio evacuation speakers and firefighter's telephones. The actual operation of the SIGA-CC1/MCC1 and SlGA-CC2/ MCC2 is determined by the "personality code" selected by the installer. It is downloaded to the module from the Signature loop controller during system configuration. The SIGA-CC1 and SIGA-CC2 mount to standard North Ameri- can two-gang electrical boxes, making them ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module. The SIGA-MCC1 and SIGA-MCC2 are part of the UIO family of plug-in Signature Series modules. They function identically to the SIGA-CC1 and SIGA-CC2, but take advantage of the modular flexibility and easy installation that characterize all UIO modules. Two- and six-module UIO motherboards are available. These can accommodate individual risers for each on-board module, or risers that are shared by any combination of its UIO modules. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Standard Features Single and Dual input (riser) select Use for connecting supervised 24 Vdc Audible/Visible signal circuits, or 25 and 70 VRMS Audio Evacuation and Telephone circuits to their power inputs. Ring-tone generator When configured for telephone circuits, the SIGA-CC1 gener- ates its own ring-tone signal eliminating the need for a separate ring-tone circuit. Plug-in (1110) or standard 2-gang mount UIO versions allow quick installation where multiple modules are required. The 2-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 6 DATA SHEET E85001-0237 Not to be used for i nstallation purposes. Issue 1 Installation The SIGA-CC1 and SIGA-CC2: mount to North American 2-1/2 inch (64 mm) deep two-gang boxes and 1-1/2 inch (38 mm) deep 4-inch square boxes with two-gang covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. SIGA-MCC1 and SIGA-MCC2: mount the UIO motherboard inside a suitable EDWARDS enclosure with screws and washers provided. Plug the SIGA-MCC1 or SIGA-MCC2 into any available position on the motherboard and secure the module to the moth- erboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to UIO Motherboard 6-32 Self-tapping screws Plug-i - - - - nUIO Captive J Module screws #6 Flat washers —Cabinet or electrical enclosure 0.75 mm2) wire size. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes Electronic Addressing - The loop controller electronically ad- dresses each module saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on- board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Personality Codes 5 and 6 apply to the SIGA-CC1/MCC1 only and are assigned by the installer. Code 7 applies to the SIGA-CC2/ MCC2 only. It is factory assigned; no user configuration is required. Application The operation of the SIGA-CC1/MCC1 and SIGA-CC2/MCC2 is determined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired ap- plication and is down-loaded from the loop controller. Codes 5 and 6 apply to the SlGA-CC1/MCC1 only. Code 7 is assigned to the SlGA-CC2/MCC2 only and automatically applies to both circuits (A and B). Personality Code 5: SIGNAL POWER or AUDIO EVACU- ATION (SINGLE RISER). Valid for the SIGA-CC1/MCC1 only. Configures the module for use as a Class B Audible/Visible Signal power (24 Vdc polarized) or Audio Evacuation (25 or 70 VRMS) power selector. The ring-tone generator is disabled. The output circuit is monitored for open or shorted wiring. If a short exists, the control panel inhibits the activation of the audible/visible signal circuit to prevent connection to the power circuit. Personality Code 6: TELEPHONE w/RING-TONE (SINGLE RISER). Valid for the SIGA-CC1 /MCC1 only. Configures the module for use as a Telephone power selector. When a telephone handset is plugged into its jack or lifted from its hook, the module generates its own Ring-Tone signal. A separate ring-tone circuit is not needed. The module sends this signal to the control panel to indicate that an off-hook condition is present. When the system operator responds to the call, the ring-tone signal is disabled. Personality Code 7: SIGNAL POWER or AUDIO EVACUA- TION (DUAL RISER). Valid for the SlGA-CC2/MCC2 only. Con- figures the module for use as a two circuit Class B Audible/Visible Signal power (24 Vdc polarized) or Audio Evacuation (25 or 70 VRMS) power selector. The single output circuit is monitored for open or shorted wiring. If a short exists, the control panel inhibits the activation of the audible/visible signal circuit to prevent con- nection to the power circuit. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. Compatibility The Signature Series modules are compatible only with ED- WARDS's Signature Loop Controller. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other perti- nent messages. Single modules may be turned off (de-activated) temporarily, from the control panel. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Page 2 of 6 DATA SHEET E85001-0237 Not to be used for installation purposes. Issue 1 Typical Wiring (SIGA-CC2/MCC2) Modules will accept #18 AWG (0.75mm2), #16 (1 .0mm2), #14 AWG (1 .50mm2) and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Bi-polar Transient Protector (PIN 235196P) (CH2 (INPUT From UL/ULC Listed j RISER IN C-) Control Panel CH2 (INPUT ( RISER IN(+) Typical Speaker Circuit Personality Code 7 UL/ULC Listed 7EED~J 471<0 EOL Personality Typical Notification Applial)ce Circuit Code 7 C) UUULC Listed 471<0 EOL le V (Class B) To Next Device CH2 (INPUT 2) RISER OUT or EOL Resistor CH2 (INPUT 2) RISER OUT (-) J Supplied with UL/ULC Listed Control Panel TB4IllIIXD(D• 14 13 12 11 ton Red LED 0 (Alarm/Active) [J8 7 6 5 4 3 TB2hlD(Jt(FCIU Ml Green LED (Normal) (CH1 (INPUT 1) From UL/ULC Usfed J RISER IN (+) Control Panel 1 CH1 (INPUT 1) RISER IN (-) From Signature I DATA IN (+) Controller or Previous Device DATA IN () To Next Device CH1 (INPUT 1) RISER OUT (i) or EOL Resistor Supplied with UL/ULC CH1 (INPUT 1) RISER OUT(-) Listed Control Panel SIGA-CC2 Notes Al For maximum wire resistance and maximum wire dis- tances, refer to IOMC Manual (P/N 270144). Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2). Refer to Signature Loop Controller Installation Sheet for wiring specifications. These modules will NOT support two-wire smoke detec- tors. All wiring power limited and supervised. If the input source is non-power limited, then maintain spacing of 1/4 inch or use FPL, FPLP, FPLR or equivalent in accord- ance with NEC. The SIGA-Ul06 does not come with TB8 through TB1 3. LfI Supervised and power-limited. zk Supervised and power-limited when connected to a power-limited source. If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. The input for this riser is common to all modules. Personality Typical Speaker Circuit Code 7 UL/ULC Listed 47KG EOL Personality Typical Notification Appliance Circuit Code 7 Bi-polar Transient Protector UL/ULC Listed (P/N 235195Pl 7<0 EOL AA AA r tO(R) series motherboard 1 2 3 4 ...- MCC2 A I LL + -1 Ri::r 1 Oat ::a': e Data Cct TTB11 . 187 ~ " J~ Data Oat _ Riser 2Out Riser 2ln Green LED (Normal l Red LED (Activel UIOR series motherboard individual Riser 1 connection. Install the jumpers between adjacent modules 1 2 3 4 that use the same riser. Riser 1 In ::_i L::::::; Riser 1 Out SIGA-MCC2 Maximum Output Load 24Vdc 25V 70V Signals Audio Audio 2A 50W 35W DATA OUT (+) DATA OUT (-) }To Next Device Page 3 of 6 DATA SHEET E85001-0237 Not to be used for installation purposes Issue 1 Typical Wiring (SIGA-CC1/MCC1) Modules will accept #18 AWG (0.75mm2), #16 (1 .0mm2), #14 AWG (1.50mm2) and #12 (2.5mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Code 5 UL/ULC Listed Personality Typical Speaker Circuit 47K0 EOL Personality Typical Telephone Circuit Code 6 UL/ULC Listed 471<0 EOL r__tk B Personality Typical Notification Appliance Circuit Code 5 UL/ULC Listed 471<0 EOL AA 1 Style V Install the Bi-Polar Transient Protector (P/N 235196P) here. (Class B) Maximum Output Load 24Vdc 25V 70V Signals Audio Audio 2A 50W 35W Data In + AS Signature — A Data () 3 Circuit Data Out V Red LED __________ ____III ________ III Green LED (Alarm/Active) 8 o 403 21 8 (Normal) hI To Next Device or From UL/ULC Listed TB UB, I----+RlSEROUT(+) EOL Resistor Supplied Control Panel __________________________RISER OUT (-) ) with UL/ULC Listed { RISER IN (+) Control Panel RISER IN (-) { DATA IN (+)> DATA OUT DATA O (+) To Next Device DATA IN (-) > W From Signature Controller A Notes Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2). Refer to Signature Loop Controller Installation Sheet for wiring specifications. These modules will NOT support two-wire smoke detectors. All wiring power limited and supervised. If the input source is non-power limited, then maintain spacing of 1/4 inch or use FPL, FPLP, FPLR or equivalent in accordance with NEC. The SIGA-Ul06 does not come with TB8 through TB13. Supervised and power-limited. Green LED (Normal) Red LED (Active) AB If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. The input for this riser is common to all modules. Personality uL/uLC Listed Code Typical Circuit !I:.:II 471<0 EOL Personality Typical Telephone Circuit Code 6 UL/ULC Listed 47K0 EOL Personality Typical Notification Appliance Circuit Code 5 471<47 EOL UL/ULC Listed - - - - X InstallolarXTrarisient Protector (P/N 235196P) here. 1 234 MCCI I I! 1_L....._ f7_-_ UIO(R( series motherboard VAAA 3 f No connections required for a))14 MCC1. Other modules may require connections. TB15 UIOR series motherboard individual Riser I connection. Install the jumpers between adjacent modules that use the same riser. SIGA-MCC1 or Previous Device SIGA-CC1 - 1 23 4 L\L -fj Riser 1 . Riser 1 Out Page 4 of 6 DATA SHEET E85001-0237 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from EDWARDS is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, net- work and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. The information stored in device memory includes: Device serial number, address, and type Time and date of last alarm (EST3 V 2 only.) Most recent trouble code logged by the detector - 32 possible trouble codes may be used to diagnose faults. Automatic Device Mapping -The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as-built" drawing information showing branch wiring (1-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: Unexpected additional device addresses Missing device addresses Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configuration and are indicated during device mapping. Page 5 of 6 DATA SHEET E85001-0237 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: edwards-fire, corn 1016 Corporate Park Drive Mebane, INC 27302 EDWARDS is a registered mark in the United States and other countries. © 2018 United Technologies Corporation. All rights reserved. Page 6 of 6 Specifications Catalog Num- SIGA-CC1 I SIGA-MCC1 SIGA-CC2 SIGA-MCC2 ber ______________________________ Description Single Input (Riser) Signal Module Dual Input (Riser) Signal Module 50 (factory set) Two sub-types 51 (factory set) One sub-type Type Code (personality codes) are available (personality code) is available (factory set) Address Require- Uses one module address Uses two module addresses ments Wiring Termina- Suitable for #12 to #18 AWG (2.5 mm2 to 0.75mm2) tions North American North American 21/2 inch (64 mm) 21/2 inch (64 mm) deep two-gang deep two-gang boxes and 11/2 boxes and 11/2 inch (38 mm) Plugs into UI02R, inch (38 mm) Plugs into U102R, Mounting deep 4 inch U106R or U106 deep 4 inch U106R or UIO6 Motherboards square boxes Motherboards square boxes with 2-gang cov- with 2-gang cov- ers and SlGA- ers and SlGA-MP MP mounting mounting plates plates Operating Current Standby = 223pA Activated = lOOpA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Output Rating 24 Vdc = 2 amps 25 V Audio = 50 watts 70 V Audio = 35 watts Construction High Impact Engineering Polymer Storage & Oper- Operating Temperature: 32°F to 120°F (0°C to 49°C) ating Environment Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use with: Signature Loop Controller Agency Listings UL, ULC, CSFM, MEA, FM Ordering Information Catalog Description Ship Wt. Number lbs (kg) SIGA-CC1 Single Input Signal Module (Standard Mount) - UL/ULC Listed 0.5 (0.23) SIGA-MCC1 Single Input Signal Module (UIO Mount) - UL/ULC Listed 0.18(0.08) SIGA-CC2 Dual Input Signal Module (Standard Mount) - UL/ULC Listed 0.5 (0.23) SIGA-MCC2 Dual Input Signal Module (UIO Mount) - UL/ULC Listed 0.18 (0.08) Related Equipment 27193-21 Surface Mount Box - Red, 2-gang 2(1.2) 27193-26 Surface Mount Box - White, 2-gang 2(1.2) SlGA-u102R Universal Input-Output Module Board w/Riser Inputs - Two Module 0.32 (0.15) Positions SlGA-UI06R Universal Input-Output Module Board w/Riser Inputs - Six Module 0.62 (0.28) Positions SlGA-U106 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) 235196P Bi-polar Transient Protector 0.01 (0.05) Accessories MFCA Multifunction Fire Cabinet - Red, supports Signature 7.0(3.1) . 0 3 1 Module Mounting Plates SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) SlGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) DATA SHEET E85001-0237 Not to be used for installation purposes. Issue 1