2016 PALOMAR AIRPORT RD; 100; FPC2019-0257; Permit
CARLSBAD, CA 92011-4400 Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0257 Status: Closed - Finaled Applied: 11/07/2019 Issued: 11/21/2019 Finaled Close Out: 02/11/2020 Inspector: Final Inspection: Print Date: 12/16/2021 Job Address: 2016 PALOMAR AIRPORT RD, # 100, Permit Type: FIRE-Construction Commercial Parcel #: 2130201800 Valuation: $709,297.54 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: PERMIT REPORT Cr'city of Carlsbad Project Title: Description: CARLSBAD JET CENTER -INSTALL FIRE ALARM MONITORING SYSTEM (ADDRESSABLE) FPContractor: COMPUTER ALERT SYSTEMS INC 27570 COMMERCE CENTER DR, # STE 119 TEMECULA, CA 92590-2501 (951) 676-6880 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov FOc O1 Submittal Package for: Jet Center 2016 Palomar Airport Road Carlsbad, CA 92008 Computer Alert Systems, Inc. 27570 Commerce Center Drive, Suite 119 Temecula, CA 92590 Contains Cutsheets and CSFM Listings for: Fire Alarm Control Panel Remote Annunciator Cellular Communicator Input Module Smoke Detector Manual Pull Station Horn/Strobe Weatherproof Horn/Strobe DPG 10/25/2019 0 6700 It supports a variety of devices, including the 6860, 5860. and 6855 remote annunciators, 5824 serial parallel printer interface module (for Printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. Jkj 6700 Addressable Fire Alarm Control Panel The 6700 isan addressable tire alarm control panel (FACP) that can be configured to achieve an overall point capacity Of LIP to 100 points. It has one built-in signaling tine circuit (SLC), which can support 50 System Sensor,' (SK) sensors and 50 SK modules or 50 Hochiki5 (SD) devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicatorfor all panels in the link for convenient single-point communications. It also has a built-in, dual- line POTs and IP communicator and optional cellular side-cars. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. SWIFT" wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard- to-wire locations, buildings where new wiring is not allowed, or to Provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has Form C trouble relay, and two programmable Form C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NEPA 72 calibration testing requirements, and calibration trouble alert. pp p'5 & BENEFITS Capable of providing up to 100 points to satisfy smaller installation needs Connect up to 17 panels on one site with convenient single.. point access using the SK-N IC Network Interface Card. Connected panels can have mixed compatible FACP models. Convenient field upgradeable firmware lntegated dual path P and POTs communications and optional cellular side.-cars for reliable backup 6860 annunciator with a 4 x 40 large display. and 4 programmable function buttons. Free -up time spent at the panel. Program them for simple or complex tasks. Built-in 058 interface for convenient and quick programming Programmable date setting for automatic and convenient Daylight Saving Time changes Built in dual phone line and digital alarm comm u iii cato r/ transmitter (DACT) for additional communication options 125 software zones and 125 output groups for flexible design options 67D0 Product Information SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, arid a built-in sensor test to complywith NFPA 72 calibration testing requirements. INDICATOR LIGHTS General Alarm (Red); Flashes if in alarm; solid when alarm is silenced Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced System Trouble (Yellow); Flashes if a trouble condition exists; solid when trouble is silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure: solid when power systems are normal USER INTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy-to-use tactile touch pad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, System silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1.000 events for viewing from the built- in or remote annunciator, System operations can be initiated with a mechanical firefighter's key or valid 4-to 7-digit operator's code. 6700 KEYPAD PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart' autoprogramming minimizes programming required to start a new system. The built-in keypad, or the 6860,5860 or 6855 remote annunciators giveyou on-site access to current system programming. You can also program the system using the Honeywell Fire Software Suite (HFSS), which is Windows based. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows , software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a Windows-based computer. ADDITIONAL INFORMATION Twisted -unshielded pair wire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). AGENCY LISTINGS AND APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service, Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non-coded) signaling services. ULListed:S2766 CSFM 7165-0559;050 FDNYCOA#6250 Seismic (CA) (pending) ORDERING INFORMATION 6700; Addressable Fire Alarm Control Panel, (Red cabinet) COMPATIBLE ANNUNCIATORS 6860:4x40 LCD rerriote lire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator, 5860 is gray; 5860R is red 6855:420 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 16 yellow). The 6865-4 has key switches for silence and reset, and a system trouble L.. ED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 nriodules on one control panel for rnaximUrn flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the 5K. SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614,350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories go to www.siLentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperture SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T: Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended air speed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-HT- Fixed high temperature thermal detector (190°F) SK-ISO: Fault isolator rriodule SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperture) SK-PHOTOR: Photoelectric detector with remote test capability SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B21OLP:6 mounting base 8501:4 Flangeless mounting base B200S: Intelligent sounder base B200S-LF: Low. frequency intelligent sounder base B224R8: Relay base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6A8:Addressable 6" base SD505-61B: Addressable 6 short circuit isolator base SD505-6RB: Addressable 6 relay base SD505-6SB: Addressable 6 sounder base SD500-AIM: Addressable input module (switch input) SDSOO-ANM: Addressable notification module SDSOO-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for the 5D505-DIJCTR SD505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR: Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 135°F"150°F(0°C-37°C). SD500-LIM: Addressable Line isolator module SD500-M M: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "P' indicates red: W" denotes white. For a complete listing of Silent Knight AV devices go to www.silentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices, It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T: Wireless Multi-criteria photoelectric smoke detector with thermal detection (135°F fixed temperture) and 8510W 4 base WSK-HEAT: Wireless Heat, (135°Ffixed temperture) and 8510W 4 base WSK-HEAT-RO R: Wireless heat, POP (135°F fixed temperture) and 8510W4 base WSK-MONITOR: Wireless monitor module WSK- RELAY: Wireless relay module W-USB:SWIFT Tools tJSB transceiver used for communication with SWIE-....devices SBUS ACCESSORIES 5496:A 6 amp notification power expander with four power-Limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/ParalLel printer interface module for printer connection. 5895XL: Power supply with six FiexputTM circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8W x 1O-3/16"H x 3D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key' CELL-MOD: Cellular communicator, plastic enclosure* *SoLe path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, celLular and/or I P (primary or backup. selectable) SK-IP-2: Remote reporting via the Internet. Requires a VisorAlarrn receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link for the 6700 SK-NIC-KIT: Installation Accessory Kit SK-FM L: Fiber-Optic Multi Mode, transmitter and receiver SK-FSL: Fiber-Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too Large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" 0 (406mm W x 254mm H x 152mm 0). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) For a complete listing of at. Overall Dimensions: 1271" W x 1512' H x 3.33" D Two programmable Circuits which can be compliance approvals and Weight: 15 tbs. programmed individually as: please. visit Color: Red NACs: 2.54 @ 271-IVDC per circuit, power-limited (with a panel maximum current of 2.54) Microsoft. Windows, and ENVIRONMENTAL Auxiliary Power Circuits: 2.54 ® 27.4VDC per the Windows Logo are Operating Temperature: 32°F to 120°F ( 0°C to circuit, power-Limited registered raceerks or trademarks of 49°C) Microsoft Corporation. Humidity: 0 to 930I0 relative humidity (non Supports Class B (Style 4) and Class A (Style 6 or 7) condensing) configuration for the SLC Silent Knight', Honeywell' and ovVlFi' are registereci trademarks of Honeywell ELECTRICAL WIRING: See the product manual for wiring details International, Inc. 6700 Primary AC: 120 VAC @60Hz, 1.54 Total Accessory Load: 2.54 @27.4 VOC power-limited This document is not Standby Current: 165m4 intended to be used for irstallation purposes. We Alarm Current: 310mA try to keep our product Battery Charging Capacity: 7 to 354H information up-to Battery Size: 7AH max. allowed in control panel date and accurate. We cannot cover air specific cabinet. Larger capacity batteries can be housed in apolicatinna or anticipate RBB accessory cabinet.. an requirements. All specifications are subject to change without notice. Foriechnical Support. call 800-446-6145i.4. For more information learn more about HoneyweLL Silent Knight and other products by visiting wwa.si ten tknight.com Honeywell Silent Knight 12 Clintonville Road CT 06472 3516507W11/17 Honeywell 800328-0103 C 2017 Honeywell international inc. 5860 Remote Annunciator Bring the power to control an lntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your lntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the lntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation. All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-446-6444, or in Minnesota, call 763-493-6435. Description Features include an 80-character backlit LCD providing easy-to- understand system messages. The annunciator is ergonomically designed with over-sized buttons for the most frequently used features, like Reset and Silence. In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The annunciator is available in gray to match virtually any decor and red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence Install up to eight 5860s per FACP Available in red or light gray Support for simultaneous use of multiple 5860s RS-485 interface to panel Operation and appearance is identical to 5860 built-in annunciator On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved Electrical Specifications Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Mechanical Specifications Physical 9.1" W x 7.4" H x 1.5" D (23.1 W x 18.8 H x 3.8 D cm) Shipping Weight: 2.8 lbs (1.3 kg) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non- condensing Approvals NFPA 72; UL Listed; CSFM 7170-0559: 135; MEA429-92-E Vol. IX; FM Approved 5860 Remote Annunciator i1i ')1 Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Rwz Up t From ACP nrk.ft1 .ACP Compatibility lntelliKnight 5820XL FACP lntelliKnight 5808 FACP IntelIiKnight 5700 FACP Ordering Information 5680R Remote Annunciator Four line LCD annunciator with 20 characters per line. Red. 5680 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring For surface mounting. 5860TG Gray Trim Ring For surface mounting. SILENT This document is not intended to be used for installation purposes. We try ENGHT D to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent by Knight 7550 Meridian Circle Suite 100, Maple Grove, MN 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350224 Rev C, 05/06 © 2007 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0501 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Silent Knight Model 6700, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). Model 6700 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NlC Network Inerface Card SK-NlC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10"HX6"D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: I20VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0501 Page 2 of 2 indicating devices. Refer to listee's Installation Instruction Manual for details. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V,G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division -- DMPCOM 000000@DMPALARMS — I( I [tii ill I 11 wiiitI1 ii nil iii 1oi i FEATURES Fully supervised universal alarm communication over LIE Program your own account number to easily work around locked panels External SMA antenna Wiring for Ademco ECP Bus Use Contact ID dialer capture, four input zones, or bell monitoring Communicates with DMP SCS-1R and SCS-VR Receivers Armed/disarmed status LED Private labeling available on the rubber logo insert Two output terminals with multiple output options Program Honeywell® VISTA® panel through CellCom using Compass® 1 CELLCOM SERIES WORKS WITH MOST PANELS If the existing panel supports Contact ID, it's a candidate for upgrading with CellCom-LTE-V or CellComF-LTE-V. There are no issues with lockout codes. Simply add the CellCom-LTE-V unit to the existing installation and program in your own account number. FIRE COMMUNICATION The CellComF-LTE-V offers cellular fire communication on any fire control panel via Contact ID captures or zone inputs. Meets NFPA 72 Standard for Single Communication Technology. MOBILE SYSTEM CONTROL With CellCom LTE communicators, you can easily update your customers' older residential and commercial systems to the latest cellular communication links. With cellular in place, end users can remotely access their panels via the Virtual Keypad app. This makes it possible to use their mobile devices to control basic arm/disarm functions and receive alerts. ENABLE VIDEO ON THE APP With the CellCom-LTE-V communicators, you can easily add up to six video cameras. Via the Virtual Keypad app, end users can remotely view their premises to cancel or verify an alarm or simply check in on children or senior adults. Users can also capture still or video images. FULLY SUPERVISED COMMUNICATION CellCom-LTE-V allows alarm messages to be communicated to an SCS-1R or SCS-VR Receiver over the Verizon LTE network. Sending alarm communication for burglary control panels over the LTE network provides higher speeds. FIELD PANEL UPDATES The Model 401 USB Flash Module allows you to easily field update firmware for panels that would otherwise require the use of a computer and a Model 399 Programming Harness. SYSTEM PROGRAMMING System programming over cell via VirtuaILink' includes zone information and monitoring center communications. MULTIPLE CONNECTION OPTIONS CellCom-LTE-V communicators can be attached to the existing panel in a variety of ways. It can capture Contact ID messages from the dialer or connect the four input zones from outputs on the panel. Or it can sense the output of the bell of an existing alarm and communicate the appropriate message to the monitoring center. FOUR ZONES Each of the CellCom-LTE-V models provide four zones for connection to burglary control panel outputs. Zone 4 is intended for connection to the control panel bell output. OUTPUTS Use outputs to connect to an arming zone of an existing panel for control of that panel via the app. EASY UPGRADE FOR DIALER-ONLY PANELS Older, dial-up panels have new life with the addition of cellular communication. Earn customer loyalty by extending the life of their existing panels and build satisfaction with the purchase decision. BUILD CUSTOMER LOYALTY Avoid the possibility of customers seeking mobile intrusion alarm features from a competitor by enabling those features on their existing panel with a minimal additional cost. They are less likely to switch systems and cancel their contract. If they choose to replace the panel, they are more likely to rely on you. DMP's Virtual Keypad app can be branded with your organization's logo and contact information to provide a daily reminder of your services. UPGRADING HONEYWELL VISTA PANELS The CellCom modules can be programmed to easily takeover Honeywell VISTA panels. The communicator can connect to a VISTA series ECP bus, which will allow you to program the Honeywell panel remotely using Compass. Specifications Dimensions 5.5W '3.75' H 1" D Color White Open-Collector Outputs 2 Zones 4 (ellCom-LTE-V Primary Power 12VDC Current Draw Alarm 99 mA Standby 51 mA CeII(omF-LTE-V Primary Power 12-24 VDC Current Draw at 12VDC Alarm 99 mA Standby 51 mA Current Draw at 24VDC Alarm 81 mA Standby 30 mA Ordering Information CellCom-LTE-V Universal Alarm Communicator CellComl-LTE-V Universal Fire Alarm Communicator Certifications California State Fire Marshal (CSFM) New York FDNY Underwriters Laboratory (UL) Listed ANSI/UL 1610 Central Station Burglar (Cellular) ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning (CID Capture) CellComF-LTE-V ANSI/UL 864 Fire Protective Signaling Systems Cellular FCC Part 15: RI7ME91OC1NV For additional information, go to DMP.com/Compliance. 800-641-4282 I DMP.com 2500 N. Partnership Bind, Springfield, MO 65803 Designed, engineered and manufactured in Springfield, MO using U.S. & global components LIMITED WARRANTY: DMP warrants that the products manufactured by DMP and described herein shall be free from defects of manufacture, labeling, and packaging for a period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the defective products are returned to DMP for inspection...To read the full DMP Limited Warranty, go to DUP.comfWarranty or check the DMP Price List or Catalog. if 2019 Digital Monitoring Products, Inc. I 11-1114 119391 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1157:0136 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Brad Tucker (417) 831-9362 Fax (417) 831-1325 Email: btucker@dmp.com DESIGN: Models CellComSLC, CellComSLCZ, CellComSLCF, CellCom-LTE-V, CellComZ-LTE-V, CellComF-LTE-V, iComSLF, iCOMSL, iComSLZ and *DuaIComNFL Communicators. Refer to listee's data sheet for additional detailed product description and operational considerations and listee's installation instructions for details. RATING: 12 VDC or 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as alarm communicators for use with separately listed fire and burglary alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. Burglary and other non-fire functions were not examined. Rev 05-13-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT by Honeywell SK-Monitor Intelligent Monitor Module The SK-Monitor module provides an interface to contact devices, such as security contacts, waterfiow switches, or pull stations. For more information about the lntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Features Single contact monitor Support for Class A and Class B wiring Fully supervised Panel controlled status LED that flashes green in normal state and is solid red in alarm Attractive ivory cover plate Rotary address switches for fast installation SEMS screws for easy wiring UL Listed Installation The SK-Monitor mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SM13500) is available from Silent Knight. Compatibility The SK-Monitor is compatible with the following lntelliKnight FACP's: 5700 5808 5820XL 5820XL-EVS Specifications Physical Height: 4.5" (11.4 cm) Width: 4" (10.2 cm) Depth: 1.25" (3 cm) Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15 - 32 VDC Current Draw (LED on): 5.0 mA max Operating Current (LED flashing): 375 pA Model SK-Monitor Intelligent Monitor Module iONEX FRDMPELOR DEVICE PREVIOUS DEVICE MCNIrCIR ANY NUIIBER Cc U. LISTED CCCT - MODULE CLOSUREDEVICESMAY BE U.ED.C3MCT lIX '. IXPiIECT PhCLLETOLI5'TECCOMPATIBLE FIRE AA4 INTIcTTIG. SUPERVISORY, OR d O .J COMOL Ft,ELE ONLY ELY DEVICES ONTIE SAME hOLLE. - RE8TOR 32 VOC MAX ELF147K TWISTED FAIR IS FEC0hE€D 14TTf4O CEVCE CIRCUIT 00q - NFPA STYLES POWIM UMTED:45(A W.O 11 VDC MAX II&SThU. CONT LOSUFE DEVICES PER ALL WIRIW EH3At4 PS SUPERVISED AND POWER LIMITED MANUFACTURER'S IRSTALLTKI4 F4ETFJCT1CM5. 2-Wire Initiating Circuit Configuration, NFPA Style B TO NEXT FROM PANEL OR DEVICE PREVIOUS DEVICE MONITOR ANY NUMBER OF UI. LISTED CONTACT MODULE CLOSURE DEVICES MAY BE USED, DO NOT MIX I 1 C ONNECTDULES TO LISTED COMRO1BLE FIRE ALARM IN11ATINO SUPERVISOR'V OR I(? O ) ) I CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE 0 EOL RESISTOR IS INTERNAL A1• TERMINALS B INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURERS INSTALLATION INSTRUCTIONS, '_i_• .....'.. ALL WIRING 8HCVN IS SUPERVISED AND POWER UNITED 4-Wire Initiating Circuit Configuration, NFPA Style D Standby Current: 400 pA max @ 24 VDC (one communication every 5 sec with 47K EOL) 550 pA max @ 24 VDC (one communication every 5 sec with EOL <1K) 5.5 mA (with LED latched on) Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information SK-Monitor Monitoring Module LED Current: 5.5 mA (with LED latched on)End-of-Line Resistance: 47K Q Accessories Initiating Device Circuit Wiring Resistance: 1,500 C2 max SMBSOO 4" Square Surface Mount Electrical SLC Loop Resistance: 40 0 max. Box D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 8200-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350131 Rev D © 2013 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURlTYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, IDP-Monitor, lDP-Minimon, lDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, lDP-Control, IDP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modules,and *IDPRELAYMON2 *SKRELAYMON2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SK-Photo (Base included) SK-Photo j I:/ 1I an d A l SK-Photo-T Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector and the SK-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight lntelliKnight Fire Alarm Control Panels (FACPs). For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103 or in Connecticut, call (203) 484-7161. Description SK-Photo and SK-Photo-T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-Photo and SK-Photo-T have a unique opt cal sensing chamber that is engineerec to sense smoke produced by a wide range of combustion sources. lr the SK-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. Features Sleek, low-profile design Base included Reliable analog communications for trouble-free operation Age res stant polymer housing Dual electronic thermistor design on the SK-Photo-T Superior EMI resistance for reliability Simple leld cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3600 visibility Detector transmits signal to indicate mainterance is required Optional remote LED annunciator (System Sensor® PN RA100Z) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed FM Approved Specifications Physical Height: 20' (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 5.2 oz. (147 g) Electrical Operating Voltage: 15-32 VDC Standby Current: 300 pA @ 24 VDC Maximum Alarm Current: 6.5 mA @ 24 VDC ma (with LED on) Environmental Operating Temperature SK-Photo: 32°— 120°F (0°C - 49°C) SK-Photo-T: 320 - 100°F (0°C - 38°C) Humidity: 10% - 93% non-condensing Other Ratings SK-Photo-T Thermal: Fixed temperature set point 135°F (57°C) Velocity: 0 - 4000 fpm (0 - 20 mfsec) SK-Photo Insect Screen Hole Size: 0.016" (0.41 mm) nominal Compatibility The SK-Photo and SK-Photo-T are compatible with the following lntelliKnight FACPs: 5700 5808 5820XL SK-Photo and SK-Photo-T are compatible with the following detector bases: B21OLP (included) 6" base 8501 2 wire base B501BHT-2 Temporal base 8224R8 Relay base 822481 Isolator base 85018H-2 Sounder base Model SK-Photo and SK-Photo-T Intelligent Photoelectric Smoke Sensors i4/1 Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with 5K-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B21OLP (included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. - / rrr'"fl 19 F' i AkwaWng ftwom D SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA IcNIG}rr keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject FORM# 350118 Rev A, to change without notice. For more information, contact Silent Knight 12 © 2009 Honeywell International Inc. y HDn"Wel Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models lDP-PHOTO, lDPPHOTOR*, lDP-PHOTO-T, lDP-ACCLIMATE, 5K-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model lDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models lDP-PHOTO and lDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT by Honeywell SK-Pull-SA and SK-Pull-DA Intelligent Pull Stations The SK-Pull-SA and SK-Pull-DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SK-Pull-DA and SK-Pull-SA provide a fast and practical means of manually initiating a fire alarm signal. The lntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the lntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK-Pull-SA is a single action pull station requiring only one motion to activate the station. The SK-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight lntelliknight series fire alarm control panels (FACP5). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK-Pull-SA SK-Pull-DA Compatibility The SK-Pull-SA and SK-Pull-DA are compatible with the following lntelliKnight FACP's: 5600 5700 5808 5820XL 5820XL-EVS Model SK-Pull-DA and SK-Pull-SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK-Pull-SA single action pull station or SK-Pull-DA, dual action pull station. SK-Pull-DA or SK-Pull-SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 lb. maximum pull force to activate the pull station. I Class A IN SLC * OUT Class 8 Compatible FACP Class A Wiring: .._ Class B Wring: - * IT, - ? T I" II I --- Wiring SK-Pull-SA & SK-Pull-DA Pull Stations Specifications Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LE)(AN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Average Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 320 - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Accessories BG-TR Optional trim ring. SB-I/O Surface backbox SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover D K1'sJIGFIT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.siIentknight.com MADE IN AMERICA FORM# 350135 Rev C © 2013 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: APPROVAL: XLF: 7150-0559:0161 7150 -- FIRE ALARM PULL BOXES SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sissonhoneywelI.com Page 1 of I Models SK-PULL-SA and SK-PULL-DA single/dual action fire alarm pull boxes. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, and UL label. Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. 7150-0028:0199 04-16-09 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Indoor Selectable Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15,3075,95115,150, and 177. Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlort and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for coiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and iorn strobes in the industry with lower current draws and modern aesthetics. With white and rod plastic housings, wall and ceiling mourting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variey of features that increase their application versatility while simplif,ing installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faufts. To further simplify installation, the L-Se-ios utilizes a universal mounting plate so installers can mou-it them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed, Installers can also eas ly adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt Dperation, and a rotary switch for horn tones with tvic volume selections. Aaencv Listinas SINAUN LISTED 55512 FM approved except 712316550504 S4011 to, ALERT mvdCts 713316550503 3057383 AVDS868.02 • 12051/2017 * Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1/?-nch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync'Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 175 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts, Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service, The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/B-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/F'NR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6,8 diameter x 2,5 high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9 diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL. SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs F, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDSBGB-02. 150112017 .Paga2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiqh 42 43 54 8-175 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd lSOcd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3,1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 11 5c 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.lKTemporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern d8 DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz. Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86B-02 • 1201,2017 • Page 3 Lo 2.47 (62.7 mm) 1.37'(34.8 mm) 6.83W A:-- (173 ry 6.92" A— (1 75. L-Series Dimensions A0545-00 A0546.Q0 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box .31 -01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes ------- Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". ,5'02017 Syttm Sens., )'STEIPi1 3825 Ohio Avenue • St. Charles, IL 60174 P,c1spacs,,s .4 SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDS868-02- 1Z,'0112017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 9fj7 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1 LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 1*I4E1TI*1:I01TITAI MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ?V,G operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR' Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrkertO Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15175, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ d8A at 16 volts Rated from -40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGNAUNG USTED SeQ ii (chimes, horrr strobes, horrro) :E APPROVED otrirrre IVIEA approved 7300.1653187(0u1d03r 725653188 (hoot strobes, strobes) 53593 (oUtdoorafld alert strobes) 3023572 M5A452.05-E 7135-1653.189 (horrrs, chi as) P t m SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling moun:ig options, and jlain or FIRE-printed devices, SpectrAlert Advance 'can meet vir:uall any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40°F to 1 El Like the entire SpeotrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase applbation flexibiity and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and thee volume options enable installers to easily adapt devices to meet requi-ernents. Next, SpectrAlert Advance devices use a unive-sal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so insta ers can verify proper wiring without mounting the devices and exposing them :o potential construction damage. Once the plates are iounted, alt' SpeotrAlert Advance devices utilize a plug-in desig with a single captured screw to speed installation and virtuall eliminate costly ground faults. Outdoor devices ship with weatherproof p-astic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining cevices. Plastic back boxes feature removable side flanges and irproved res stance to saltwater corrosion. Knock-juts located on the back eliminate the need to drill holes for screw-in mounting. P astic and metal weatherproof back boxes come with 3/4-inch top aid bottom concuit entries and 3/4-inch knock-outs at the back. A screw-in NPT p ug with an 0-ring gasket t or a watertight seal is includcd with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting coiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync'Circuit" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync'Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system, The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5,6"L x 4.7'W x 2.5'D (142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7'W x 1.3"D(142 mm Lx 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7'L x 5.1 "W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15175 cd. AVDSO 1201 UL Current Draw Data UL Max, Strobe Current Draw (mA RMS) "7'WUr-Tt"Itqqj=I I. 8-175 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-175 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela iso NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA rE. Draw (mA RMS) 2-Wire Horn Strobe, Standard 8-175 Volts 16-33 Volts DC Input 15 15175 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low vJ Max. . -1Draw (mA DC Input 132 154 Horn 16-33 Volts 135 150 Strobe, 177 80 High Candela 185 90 Range (135-185 cd) 105 FWR Input 161 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data Horn and HornStrobe, Output (04) 8-17:5 16-33 Volts Volts 24-Volt Nominal Reverberant Anechoic Strobe Output (ad) Listed Candela Candela rating at -40F 15 Do not use below 32°F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 Position Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 Wall-Mount Horn Strobes erproof Back Box S trAIert Advance Diacir ms Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*1 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWKt Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*I Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-P' to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate. WTP and WTPW. "Standard cd" refers to strobes that include 15. 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135. 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 4 02012 system Se-o,~ SYSTEM 3825 Ohio Avenue . St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 pduct nrornare an ,eav*rs** of this dotasfot, • CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennetthoneywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix 'P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-W88C (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDCIFWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh TO This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division