Loading...
HomeMy WebLinkAbout2051 PALOMAR AIRPORT RD; 120; FPC2017-0335; PermitPERMIT REPORT ((7C- i ty of Carlsbad CARLSBAD, CA 92011-1462 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check#: Plan Check #: Permit No: FPC2017-0335 Status: Closed - Finaled Applied: 11/14/2017 Issued: 12/01/2017 Finaled Close Out: 02/03/2021 Inspector: Final Inspection: Print Date: 12/16/2021 Job Address: 2051 PALOMAR AIRPORT RD, # 120, Permit Type: FIRE-Construction Commercial Parcel #: 2130503900 Valuation: $501,512.04 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: REAL CAPITAL MARKETS -SPRINKLERS TI 7-100 (30) Applicant: FPContractor: TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611 S MELROSE PL, #244 1611A S MELROSE DR VISTA, CA 92081-5471 VISTA, CA 92081-5407 (760) 525-4329 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 760-602-8561 f I www.carlsbadca.gov 3 2051 PALOMAR AIRPORT RD # 120 FPC2OI7-0335 REAL CAPITAL MARKETS - SPRINKLERS TI 7-100 (30) tt 2130503900 11/14/2017 FPC20I 7-0335 MATERIAL DATA SUBMITTAL Real Capital 2051 Palomar Airport Road Carlsbad, CA 92011 Page # Description Manufacturer 1-2 Pipe Allied Dyna-Thread Pipe 3-10 Fittings Tyco Ductile Iron Fittings 11-12 Mechanical Tee Tyco Fig 40-5 Strap Tee 13-18 Sprinkler Reliable F 1 56 Sprinkler 19-25 Sprinkler Reliable F1FR56 Sprinkler 26 Hanger Afcon Fig. 300 Ring Hanger 27 Hanger Afcon Fig 655 All Thread Rod 28-29 Attachment Sammy Wood Vertical Mount Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpjohnc©gmail.com -I DynawThreade S Full Line Sch-40 Replacement Dyna-Thread' offers the fife expectancy of Sch4O with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 * Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is filly listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (@ <~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. IISpecificationsiI:WApprovals Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40IDyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40fDyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. WI. (H20 Filled) PeW WI/lift (21'} WI/lift (24') Wt/Lift (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 11R 1.408 1.870 2,54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1'/z 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2' 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 16100 S. Lathrop• Harvey, IL 60426 tqco/Flow Control ) dhed 11350 Norcom Rd. Philadelphia, PA 19154 TUBE& CONDUIT 2525 N. 27th Ave. 'Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 S3-3 Submittal Data Sheet . Dyna-Thread Full Line Sch-40 Replacement Stamp Here Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. S Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTMA 135, Grade and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Specifications NPS Nominal I.D. M. WI. (H20 Filled) Pcs/ WVI.ilt (21') WtiUft (24') Wt/1.ift (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 11 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 11R 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1h/2 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: S3-4 tqCo Fire & Building IPro duc ts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Pipe Fittings NPT Threaded, Ductile Iron General Description The Tyco* Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI B1.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired- in accordance with applicable JANUARY, 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular ouroose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or detect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. tregistered trademark of E. I. du Pont de Nemours and Company or Its affiliates. TFPI7IO Page 2oflO TFPI7I0 S r A it FIGURE 811 FIGURE 813 900 ELBOW 450 ELBOW TABLE I NOMINAL DIMENSIONS FIGURES 811 & 813 Figure 811 Figure 813 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19,0) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0,29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (30,2) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0.79) (42,7) (23,9) 1.56 3.28 86204 1.94 1.00 (39,6) (1,49) (49,3) (25,4) Nominal Pipe Size ANSI A Approx. Inches Inches Weight Part DN (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 DN15 (28,7) (0,09) 3/4 1.31 0.33 86781 DN20 (33,3) (0115) 1 1.50 0,48 86280 DN25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 0N32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2.25 1.55 86283 DN50 (57,1) (0,70) 2-1/2 2.69 2.70 86782 DN65 (68,3) (1,22) 0 TFPI7IO Page 3 of 10 FIGURE 812 900 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Weight Part Inches Inches Inches Inches Inches Lbs. Number DN (mm) (mm) (mm) (mm) (kg) 3/4x1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20 x 15 (30,2) (30,2) (16,0) (16,0) (0,15) 1 x 1/2 1.25 1.38 0.56 0.81 0.44 86210 DN25 x 15 (31,8) (35,1) (14,2) (20,6) (0,20) 1 x314 1.38 1.44 0.69 0.88 0.53 86211 DN25x20 (35,1) (36,6) (17,5) (22,4) (0,24) 1-1/4x1/2 1.31 1.50 0.63 0.94 0.64 86212 DN32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-1/4 x 3/4 1.44 1.63 0.75 1.06 0.75 86213 DN32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 1-114x1 1.56 1.68 0.88 1.00 0.77 86214 DN32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35) 1-1/2x3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40 x 20 (38,1) (44,4) (1910) (30,2) (0,43) 1-1/2 x 1 1.63 1.81 0.88 1.13 0.99 86215 DN40x25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-1/2x1-114 1.81 1.88 1.13 1.19 1.14 86216 DN40 x 32 (46,0) (47,8) (28,7) (30,2) (0,52) 2x314 1.63 1.94 0.88 1.38 1.39 86217 DN50x20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 DN50 x 25 (44,4) (52,3) (50,8) (33,3) (0,72) 2 x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50 x 40 (50,8) (55,6) (31,8) (36,6) (0,76) 2-1/2 x 2 2.38 2.63 1.25 1.88 3.01 86262 DN65x50 (60,5) (66,8) (31,8) (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 (D L 0 TFPI7I0 Page 5of 10 I—Al 1J I LWii FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 Figure 814 Figure 818 A B Approx. A B Inches Inches Weight Part Inches Inches (mm) (mm) Lbs. Number (mm) (mm) (kg) 1.13 0.56 0.33 86340 1.38 0.31 (28,7) (14,2) (0,15) (35,1) (7,9) 1.31 0.75 0.50 86341 1.63 0.56 (33,3) (19,0) (0,23) (41,4) (14,0) 1.50 0.81 0.85 86230 1.75 0.38 (38,1) (20,6) (0,38) (44,4) (9,7) 1.75 1.06 1.30 86231 2.00 0.56 (44,4) (26,9) (0,59) (50,8) (14,0) 1.94 1.19 1.63 86232 2.19 0.75 (49,3) (30,2) (0,74) (55,6) (19,0) 2.25 1.50 2.63 86233 2.63 1.13 (57,1) (38,1) (1,19) (66,8) (28,7) 2.69 1.56 4.55 86234 3.00 0.75 (68,3) (39,6) (2,06) (76,2) (19,0) Nominal Pipe Size Approx. ANSI Inches Weight Part DN Lbs. Number (kg) 1/2 0.18 72779 DN15 (0,08) 3/4 0.26 72778 DN20 (0,11) 1 0.44 72755 DN25 (0,20) 1-1/4 0.54 72754 DN32 (0,24) 1-1/2 0.71 72753 DN40 (0,32) 2 1.15 72752 0N50 (0,52) 2-1/2 2.29 72758 DN65 (1,04) 0 TFPI7I0 Page 6of 10 S S S EA Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 A B C 0 E F Approx. ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part DN Lbs. Number (mm) (mm) (mm) (mm) (mm) (mm) (kg) 1-1/2x1-1/4x112 1.44 1.31 1.69 0.69 0.63 1.13 1.03 86257 DN40x32x15 (36,6) (33,3) (42,9) (17.5) (16,0) (28,7) (0,47) 1-1/2x1-1/4x314 1.50 1.44 1.75 0.75 0.75 1.19 1.10 86258 DN40x32x20 (381) (36,6) (44,5) (19,0) (19,0) (30,1) (0,50) 1-1/2x1-1/4x1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 86259 DN40 x 32 x 25 (41,4) (39,7) (46,0) (22,4) (22,4) (28,7) (0,59) 1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 86260 DN40x32x50 (55,6) (54,1) (500 (36,6) (36,6) (57,1) (0,88) 1-1/2x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 86261 DN40x40x15 (36,6) (36,6) (42,9) (17,5) (17,5) (28,7) (0,52) 1-1/2x1-1/2x314 1.50 1.50 1.75 0.75 0.75 1.19 1.23 86262 DN40x40x20 (38,1) (38,1) (44,4) (19,0) (19,0) (30,1) (0,56) 1-1/2x1-1/2x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 86263 DN40 x 40 x 25 (41,2) (41,2) (46,0) (22,4) (22,4) (28,7) (0,62) 1-1/2 x 1-1/2 x 1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 86264 DN4O x 40 x 32 (46,0) (46,0) (47,6) (27,0) (27,0) (30,1) (0,68) 1-1/2 x 1-1/2 x 2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 86265 DN40x40x50 (55,5) (55,5) (50,8) (36,6) (36,6) (31,7) (0,91) 2x1 x2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 86266 DN50x25x50 (57,2) (50,8) (57,2) (38,1) (33,3) (38,1) (0,99) ______ 2x1-1/4x2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 86267 DN50x32x50 (57,2) (54,1) (57,2) (38,1) (36,6) (38,1) (1,05) 2x1-112x112 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 DN50x40x15 (38,1) (36,6) (47,8) (19,0) (17,5) (33,3) (0,68) 2x1-1/2x314 1.63 1.50 1.94 0.88 0.75 1.38 1.61 86269 0N50 x 40 x 20 (41,4) (38,1) (49,3) (22,4) (19.0) (35,0) (0,73) 2x1-1/2x1 1.75 1.63 2.00 1.00 0.88 1.31 1.65 86270 DN50x40x25 (44,5) (41,4) (50,8) (25,4) (22,4) (33,3) (0,75) 2x1-112x1-112 2.06 1.94 2.19 1.31 1.19 1.44 2.03 86272 DN5O x 40 x 40 (52,4) (49,2) (55,5) (33,3) (30,2) (36,6) (0.92) 2x1-1/2x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 86273 DN5O x 40 x 50 (57,1) (55,5) (63,5) (38,1) (36,6) (38,1) (1,07) 2x2x112 1.50 1.50 1.88 0.75 0.75 1.31 1.50 86222 DN50x50x15 (38,1) (38,1) (47.8) (19,0) (19,0) (33,3) (0,68) 2 x 2 x 3/4 1.63 1.63 1.94 0.88 0.88 1.38 1.67 86223 DN50x50x20 (41,4) (41,4) (49,3) (22,4) (22,4) (35,0) (0,76) 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 86224 DN50 x 50 x 25 (44,5) (44.5) (50.8) (25,4) (25,4) (33,3) (0,86) 2 x 2 x 1-1/4 1.88 1.88 2.13 1.13 1.13 1.44 2.05 86225 DN50 x 50 x 32 (47,8) (47,8) (54,1) (28,7) (28.7) (36,6) (0,93) 2x2x1-112 2.00 2.00 2.19 1.25 1.25 1.50 2.11 86226 DN50x50x40 (50,8) (50,8) (55,6) (31,8) (31,8) (3811) (0,96) 2x2x2-1/2 2.63 2.63 2.38 1.75 1.88 1.44 3.67 86227 DN50x50x65 (66,8) (66,8) (60,5) (44,5) (47,8) (36.6) (1,66) 2-1/2x2x3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 86274 DN65x50x20 (44,5) (41,4) 1 (58,7) (15,9) (22,4) (44,5) (1,01) TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 S Page 8 of 10 TFPI7IO F -17 .- -,, " I ~Lrw48%-wHjMw60 FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Figure 820 Figure 830 Figure 719 Size ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part DN (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) (kg) 1/2 0.88 0.15 72776 1.88 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0,06) (47,8) (20,6) (0,21) (23,9) (0,04) 314 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 DN20 (25,4) (0,10) (50,8) (23,9) (0,30) (28,7) (0,08) 1 1.18 0.33 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 DM25 (30,0) (0,15) (55,6) (20,6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72756 2.50 1.06 1.54 86277 1.38 0.50 86295 DM32 (33,3) (0,24) (63,5) (26,9) (0,70) (35,1) (0123) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 86296 DN40 (35,1) (0,31) (66.8) (30,2) (0,92) (36,6) (0,32) 2 1.50 0.96 72823 3.13 1.63 3.15 86279 1.50 0.90 86297 DN50 (38,1) (0,43) (79,5) (41,4) (1,43) (381) (0,41) 2-1/2 1.75 1.80 72825 - - - - - - - 0N65 (44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820, 830 & 719 0 S TFPI7I0 Page 9of 10 S IAJ FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING TABLE 7 NOMINAL DIMENSIONS FIGURE 825, 827 & 816 Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI inches Inches Weight Part Inches Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - DN15x 15 (38,1) (0,09) 1/2 x 1/2 2.00 0.27 72980 - - - - - - DN15 x 15 (50,8) (0,12) 3/4x3/4 1.50 0.22 72981 - - - - - - - DN20 x 20 (38,1) (0,10) 3/4 x 3/4 2.00 0.31 73982 - - - - - - - 0N20 x 20 (50,8) (0,14) 3/4x 1/2 - - - 1.75 0.69 0.38 86772 DN20x 15 - - (43,2) (17,5) (0,17) 1 x1/2 - - - 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25 x 15 (26,9) (0,10) (42,9) (12,7) (0,17) 1 x3/4 - 1.06 0.18 72762 1.75 0.50 0.53 86229 DN25x20 (26,9) (0,08) (43,2) (12,7) (0,24) 1-1/4x1 - - 1.19 0.31 72763 - - - - DN32x25 (30,2) (0,14) 1-1/2x 1 - - - 1.25 0.53 72757 - - - - DN40 x 25 (31,7) (0,24) 1-1/2x1-1/4 - - 1.25 0.35 72764 - - - - DN40x32 (31,7) (0,10) 2x1 - - - 1.38 0.75 72759 * - - - DN50x25 (35,1) (0,34) 2x1-1/4 - - 1.38 0.69 72761 - - - - DN50x32 (35,1) (0,31) 2 x 1-1/2 - - - 1.38 0.62 72775 - - L - - DN50x40 (35,1) (0,28) ______ Description S Listing/Approval Inlormatlon tJJCG /Fire & Building I Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap General The Figure40-5 Strap is an economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as wellas with theapplicablestandards of the National Fire Protection Association, in addition to the standards of anyotherauthorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkiermanufacturershouldbe contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS: See Fire Protection Submittal Sheet for exact Listing /Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM B-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade "E" EPDM green color code. (See Data Sheet 1FP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade 'E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their lire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The Installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be Immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Are Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and property installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Are Products. No warranty is given for products or components manufactured by companies not affiliated by ownership withTyco Fire Products orfor products and components which have been subject to misuse, improperinstallation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any otherAuthorities Having Jurisdiction. Materials found byTyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumefarit,anyotherobligationinconnectionwith the sale of products or parts of products. Tyco Fire Productsshallnotberesponsibloforsprinklersystern designerrorsorinaccurateorincompleteinformation supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHEHERTYCO FIREPRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALLTYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. Page 1 of 2 September 2004 TFPI72O Pipe Nominal Dimensions Hole Net Size Size Wt. A B C D Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. iVi" X 1/20 2.00 1.50 3.50 1.20 1/io 0.84 50.8 38.1 88.9 30.5 30.2 0.4 1'/4 x 3/4"2.00 1.50 3.50 1.20 13/16 0.88 50.8 38.1 88.9 30.5 30.2 0.4 11/40 x 1' 2.31 1.68 3.50 1.20 1/16 1.13 58.7 42.7 88.9 30.5 30.2 0.5 11/20 X /2° 2.12 1.62 3.50 1.32 1/is 0.84 53.8 41.1 88.9 33.5 30.2 0.4 x 3/0 2.12 1.62 3.50 1.32 1/16 0.88 53.8 41.1 88.9 33.5 30.2 0.4 1/2" X i 2.43 1.80 3.50 1.32 1/16 1.13 61.7 45.7 88.9 33.5 30.2 0.5 20 x 1/2"2.36 1.86 3.74 1.55 1/i 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2X3/4° 2.36 1.86 3.74 1.55 1/16 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2°x 1' 2.67 2.04 3.74 1.55 1/l6 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/2' X 1/2 2.61 2.11 4.25 1.80 1/i 0.90 66.3 53.6 108.0 45.7 30.2 0.4 21/2" X314" 2.61 2.11 4.25 1.80 1/t6 0.99 66.3 53.6 108.01 45.7 30.2 0.4 21/2 i 2.92 2.29 4.25 1.80 1/l6 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt S The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Fitting Size Equivalent Length (1 inch pipe) 11/4°X 1 8 1'/20X 10 6 2°x 1° 6 21/?x 1' 4 Page 2 of 2 TFPI72O Figure 40.5 Strap S The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH.1000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Bulletin 013 Rev. L Re - ® Models Fl Series iable Standard Response _ Standard Spray I— S Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F156 Recessed Sprinkler Types Pen dent/F 1/F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent/F1/F2/FP Approval Organizations Underwriters Laboratories Inc. and certified for Canada (cULus) Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH EC Certificate: 0786-CPD-40237 (RA1314) 0786-CPD-40253 (RA1 325) 0786-CPD-40254 (RA1 375) UL Listing Category Sprinklers, Automatic & Open (VNlV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 Recessed Recessed XLH Upright Horizontal Sidewall Pendent/FP XLH Pendent Pendent F1/F2 XLH Recessed Pendent FP The F156, F142, F1XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F156, F142, F1XLH & F128 Series Sprinkler tem- perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Pin tie S (XLH Only) Deflector Load Screw Washer Bulb Frame Cup S 0 13FG04 Model F142, F1XLH Upright Technical data: Models Discharge Coefficient Response Thread Max. Working Mm. Working Temperature Finish Size Pressure Pressure Rating F156 K5.6 1/2" NPT See See F142 F1XLH K 4.2 Standard (R1/2) 175 PSI 7 PSI "Temperature 'Finish Table" Ratings" Table F128 K2.8 Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or or coated with FIFE Adhesive Glass CDAAlloy510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape S 2. S Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K Factor ______________ Sprinkler Height Approval Organization .1 Sprinkler Identification Number (SIN) US IMetric Upright Pendent I Standard -Upright (SSU) and oendent Deflectors Marked to Indicate Position 1/2"(15mm)(1) 1/2"NPT(R1/2) 5.6 I_80 2.25"(57mm) 1,_2,_3,_4,_5 I_ 7/16"(10mm) 1/2"NPT(191/2) 4.2 2.25"(57mm) 1 RA132326 I_RA1313 3/8(10mm) 1/2"NPT(R1/2) 2.8 I_40 _60 2.25"(57mm) 1 RA132126 I_RA13116 Conventional-Install in Upright or Pendent Position 15mm (1) I 1/2" NPT (R1/2) I 5.6 I 80 I 57mm I 3.4.5 I RA1375)5) Refer to Bulletin 024 for Special Response Sprinklers (F1S5-56) cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM Approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1325, RA1314 & RA1375. Electroless Nickel PTFE (Teflon®)* Plated - UL listed Corrosion Resistant Upright Pendent Conventional Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers0 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread KFactor Sprinkler Height Sprinkler Identification Number (SIN) US 1/2"(15mm) (R1/2) 5.6 2.25"(57mm) RA1314 2 7/16"(10mm) _Size _1/2"NFl 4.2 _Metric _80 2.25"(57mm) RA1313 2 3/8(10mm) _1/2"NPT(R1/2) _1/2"NPT(R1/2) 2.8 _60 _40 2.25"(57mm) RA13112 Refer to escutcheon data table for approvals & dimensions Electroless Nickel PTFE (Teflon)5 Plated - cULus listed Corrosion Resistant - 1 I/fRED/RED FACE OF TIE/INC IV FACE OF CE/USC CEMENSION AT MIX/MUM RECESS - IT25Arna,J AT MW/MUM RECESS - 3/875.5mm) /CE.ESCVESCERE 1/ AT MIX/MUM RECESS - 3/4Tlsmmj AT MINIMUM RECESS 3/579.5mm) Fl_IICERIIN AT MIX/MUM RECESS - 7/8722.2mm) JAT MINIMUM RECESS "'T, 3m fr I AT MIX/MUM RECESS - I- , 11812,0 Em, AT MINIMUM RECESS - 1-/81." 2 27/32 GEl. 0 SEX IC RECESSEDPENDENT win ORF2ESCUTCHEON SPRNKLD NOT FM AFPRS/ED ME/I Fl ESCUTCHEON Model F156, F142, F1XLH & F128 Fl or F2 *DuPont Registered Trademark 3. F I/2 REDUCER 2 5/8 0/A. (6N.7,ss,) HOLE IN CEILING 2 5,'I6 DIR. (507mm) CUP FACE OF /117/S/S I TO FACE OF CEILING I DIMENSION Y,5O8mm/ I ~AF AT MIX/MUM RECESS - 1-1/2138mm ] CE/US/C MINIMUM RECESS I 7254mm) MUM RECESS = 9/76174.3mm) MINIMUM RECESS I 125.4mm) ADJUSIMENT ________ (82.6Xs1,) RECESSED PENDENT W/FPESCUTCHEON OLNINCO -SPRINKLER NOT FM APPRSkCD WITH FR ESCUTCHEON Model F156, F142, F1XLH & F128 FP C Vertical Sidewall Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4(102mm) - 12" (305mm) Installation Data: Nominal Orifice Thread Size I I Nominal K Factor I Sprinkler Height I Approval (1) I Organizations Sprinkler Identification I US I I Metric Numbers (SIN) ½" (15mm) ½" NPT(R1/2) 5.6 8.0 2.25" (57mm) 1,2,3 (1) LPC Approval is pendent only, 57°C through 141°C ratings. 2) cULus Listed corrosion resistant (Polyester coated) sprinkler. 3 cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. 4) Electroless Nickel PTFE (Teflons)* Plated - cULus listed Corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 725.4mm1 AT MINIMUM RECESS = 3/B 79.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4719mm] AT MINIMUM RECESS = 3/879.5mm] r-2 1/4 HOLE 0/A. [5 7.2mm] 1 X 1/2 REDUCER - I 2 27/32OIA. TURN COLLAR UNTIL - I7GHT AGAINST SPRINKLER Fl ESCU J14"[19mm] ADJUSTMENT TCHEON WRENCH BOSS. ff —i I (I) 4-12 [ID l.6mm-304.8mm] CEILING TO DEFLECTOR Fl ESCUTCHEON AT MAXIMUM RECESS = 1-3/8734.9mm] AT MINIMUM RECESS = 2-1/16752.4mm1 V • F2 ESCUTCHEON AT MAXIMUM RECESS 7-5/8741.3mm] AT MINIMUM RECESS = 2-1/16752.4mm] 1/2712.7mm3 ADJUSTMENT RECESSED HSW W/F1 OR 12 ESCUTCHEON (I) FM APPROVED FOR 4 - 6 [101.6MM - 152.4MM] CEILING TO DEFLECTOR. Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. FM and cULus permits use with Fl or F2 escutcheons for Installation Data:Horizontal Sidewall "Light Hazard" only. Nominal K Factor __________________ Sprinkler Height Approval Organizations Sprinkler Nominal Orifice Thread Size Identification I US Metric Light Hazard I Ordinary Numbers (SIN) Hazard ½" (15mm) ½" NPT(R1/2) 5.6 80 2.63" (67mm) 1,2 1 1 cULus Listed corrosion resistant (Polyester coated) sprinkler. (2) cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (,')Polyester coated FM approved sprinkler. (4) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant *DuPont Registered Trademark 4. S S Application Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH & Fl 28 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry Deluge or Preacon. Care must exercised that the orifice size, temperature rang, deflector style and sprinkler type are in ac- cordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdic- on Installation. Installation Model F156, F142, F1XLH & F128 Series sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of 3/4 inch (19mm). The Model Fl, F2, and FP Escutcheon illustrated are the only recessed escutcheon to be used with the Model F156, F142, F1XLH & F128 Recessed Sprinklers. The use of any other recessed escutcheon Will void all approvals and negate all warranties. When installing Model F156, F142, F1XLH & F128 Recessed Sprinklers use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak tight l/2" NPT (R 1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating: - Specify when ordering - Model F156 Pendent Sprinkler Sprinkler Finish Escutcheon Finish (where applicable) Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (1) (1) SIN: RA1335 - cULus and FM permits use with Fl or F2 escutcheons for light hazard only. *DuPont Registered Trademark Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1X- LH & F128 Recessed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause im- proper operation or non-operation. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color OC OF Ordinary 57 135 100°F(38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High1 141 286 225°F (107°C) Blue Extra High" 182 360 300°F (149°C) Mauve Ultra High ((2) 260 1 500 1 475°F (2461c) I Black Not available for recessed Sprinklers. cULus listed for SIN RA1325 and RA1314 only. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finish 1 Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Polyester Coated (6))1)(9) White Painted Special Appll'itlon Finishes Srrinkier Escutcheon Electroless Nickel PTFE(Teflon®)*)3X10( Electroless Nickel PTFE (Teflon®)* Bright Brass2 Bright Brass Black Plated Black Plated Black Paint39 Black Paint Off White (3)(9) Off White Chrome Dull Chrome Dull Lead Wax Wax Over (1) Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. (1) 200'F (93°C) maximum. UL and ULC listed only. °155°F to 200°F (68°C to 93°C) ratings only. 286'F (141°C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). cULus listed "corrosion resistant' applies to SIN Number RA1325 (Upright) R.A1323 (upright), RA1321(Upright), RA1335 (HSW), RA1385(VSW) and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approved finish as "Polyester Coated" applies to SIN number RA1314, RA1335 & RA1325 in standard black or white. FM Approved finish applies on/ to SIN number RA1335 & RA1385. (9) LPCB and VdS Approved finish applies only to RA1325, RA1314 and RA1375. (11)cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1323, RA1313 .RA1321. RA1311. RA1385 and RA1335 5. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers S • Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly .qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Act Recycled ® (800) 431-1588 Sales Offices Paper Reliabl e (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. (800) 848-6051 Sales Fax www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 04/15 P/N 9999970299 F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely XLH Upright XLH Pendent Conventional Recessed PendentjF1/F2 (1 Recessed Pendent/FP XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Upright Pendent Vertical Sidewall Horizontal Sidewall Recessed Concealed Horizontal Sidewall Pendent Bulletin 014 Rev. L O liable Model Fl FR Series Quick Response Standard Spray Cc C :3 C -4 Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Ei Model Fl FR56 Recessed Sprinkler Types Standard Pendent/Fl/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model F1FR42, F1FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types . Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhütung GmbH 5 *J5 Certified to NSF/ANSi Standard 61 Annex G 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA 1425), 0786-CPD-40252 (RA1 475) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, . F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR56, F1FR56LL, Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be • exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *Pin tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup S 0 14F006A Model F1FR42, F1FRXLH Upright Technical data: Thread Max'Mm. Temperature Models Discharge Coefficient Response Working Working Finish Size Pressure Pressure Rating F1FR56 **F1 FR56LL0) K 5.6 Quick 1/2" NPT See See F1FR42 **F1 FR42LL' K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" F1FRXLH Ratings" Table. F1FR28 K2.8 "Low Lead Sprinklers available only with Temperature Rating 200°F/930c Material Data: Frame Deflector Load Screw *pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or coated with PTFE Adhesive Glass ""Low Lead Brass or CDA Alloy5lo CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape 2. Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers . Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread ____________ Nominal K Factor _______________ Sprinkler __________ Approval __________ Sprinkler Identification Number (SIN) Size US J Metric Height Organization Upright J Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1, 2, 31' 4, 6 7/16' (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA1423 14 RA1413 4 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA142114 RA14114 Conventional-Install in Upright or Pendent Position 15mm (1) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 1 RA14753 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread ____________ Nominal K Factor ________________ Sprinkler (SIN) __________ Approval __________ Sprinkler Identification Number Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm)1) 1 1/2" NPT (R1/2) 5.6 I 80 [ 2.25"(57mm) 1,5 RA1415 7/16" (11mm) 1/2" NPT (R1/2) 4.2 _60 [ 2.25"(57mm) 1,5 RA1410 ) cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark 3. 4. Vertical Sidewall *DuPont Registered Trademark Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4(102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) S Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1413 3/8" (10mm) 1 1/2" NPT(R1/2) 2.8 40 j 2.25" (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415 7/16" (10mm) I 1/2" NFl (R1/2) 4.2 60 1 2.25" (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions —'r-- F COLLAR -? H E/a CamE LIGEL EIGHT I ncalsr COOPeRS V FACE OF ACONG I- IS FACE OF CEILING U/POiSON ESCEflESCEON L MINIMUM RECESS J/BT95~~] AT — RECESS 314T-1 AI)—wEwT AT MINIMUM RECESS 318`rl~] t Il ill ff11 AT PeRIPLIP RECESS 7/8j22. i4 2,,,,n) 1.Jn,,I N 1111 d-i V#O,JSF I-S/B J AT AUXIMUM RECESS I-I/8T2G6,,,,,,J AT MINIMUM RECESS I-5/8T4LJX,,o1 Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28F1 or F2 IX I/2RECXIEER 2 5/8rn ELi. [6& 7-1 HOLE IN CUlLING 2 5/I6 OLC. (5&7R,mJ CUP G4CU OF FITTING 70 FACE OF ECEUNG CEMEIGON IT AUMHIMUU RECESS - IT MINIMUM RECESS - ' AT AMXIMUM RECESS - 9/I67I4J,n,oj AT MINIMUM RECESS - AWLCECEUXIT I (82.6evn1 Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) ½" (15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3 RA14851213 15mm ½" NPT (R1/2) 5.6 I 80 2.25" (57mm) 3(1) LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant Horizontal Sidewall Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Sprinkler _________________ Height and Type of Approval Nominal Orifice Thread Size Identification US Metric Light Hazard I Ordinary Numbers (SIN) Hazard 1/2" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant I - -- I .—I T (1) iA7, 1 15/76" OIA.J' 4"-12" [ID l.6mm-304.8mm] 32 0)4 CEILING TO [49.2mm] 2 27/ [72.2mm] DEFLECTOR TURN COLLAR UN TIGHT AGAINST SPRINKLER I Fl ESCUTCHEON WRENCH BOSS I 3/4779mm] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT RECESSED HSW W/F1 OR F'2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [70 7.6MM - 752.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1"[25.4mm] AT MINIMUM RECESS 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4[19mm] AT MINIMUM RECESS 3/8[9.5mm] 2 1/4 HOLE DIA. [57.2mm] I" X 1/2" REDUCER Fl ESCUTCHEON AT MAXIMUM RECESS 1-3/8734.9mm] H / AT MINIMUM RECESS 2-1/16752.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8741.3mm] l—,' AT MINIMUM RECESS = 2-7/16752.4mm] [3.2m m] Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with Fl, F2 or FP escutcheons for "Light Hazard" only. While FM limits use for the same hazard with the F2 escutcheon only. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) US Metric Sprinkler Cover ½" (15mm) 5.6 80 ½" NPT F1FR 135°F/570C 135°F/570C 100°F/38°C Orange 1 RA1414 ½" (15mm) 5,6 80 ½" NPT I F1FR 1550F/680C 1350F/570C 100°F/380C Red 1, 4(1), 6 RA1414 ½" (15mm) 5.6 80 ½" NPT F1FR 1750F/790C 1650F/740C 100°F/38°C Yellow 1 RA1414 ½" (15mm) 5.6 80 ½" NPT F1FR 200°F/930C 1650F/740C 150°F/650C Green 1 RA1414 (1) For VdS only = 155°F/68°C Norbulb and 1/2" [12,7mm] adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor I Thread Size I I Model Temp. Rating Max. Ambient Bulb Color Approvals Sprinkler Identification US Metric! Sprinkler I I Cover Temp Number(SIN) ½" (15mm) 5.6 80 ½" NPT F1FR56LL 200°F/930C 1650F/74°C 150°F/65°C Green 1,5 RA1414 *DuPont Registered Trademark 5. - 2 5/8" 0/A. HOLE IN CEILING 1 1/2' MAX. FACE OF FITTING , TO FACE OF CEILING DIMENSION 3/4" -2 5/8" DIA. HOLE IN CEILING 1 1/2" MAX. FACE OF FITTING .._.._..TO FACE OF CEILING DIMENSION 15/16" I" x 1/2" REDUCING TEE OR ELBOW '"' 2 5/16" DIA - CUP CEILING -' - 1/2" MAX. I COVER ADJUSTMENT COVER PLATE - 5/16" 0/A. ASSEMBLY SPRINKLER 1" x 1/2" REDUCING TEE OR ELBOW 2 5/16" 0/A - CUP-_.. COVERADJUSTMENT COVER PLATE- 5/16" MAX. JL 3 751, ASSEMBLY IA. SPRINKLER S CONCEALED, 1/2" ADJUSTMENT Figure 1 Installation Aid A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model COP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & El FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R112) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models Fl FR56/OCP & Fl FR56LLICCP Concealed Sprinkler use the ½" orifice, 1/2" NPT (R1/2), Model F1FR56 & Fl FR56LL Pendent Sprinkler with a threaded Model COP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The Model F1FR56LL Pendent is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model COP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the F1FR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark 101 CONCEALED, 5/16" ADJUSTMENT Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2/8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RO1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RO1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model COP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. [1 Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color 0 I OF Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100-F (38-C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High (1) 141 286 1 225°F (107°C) Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 - cULus permits use with Fl F2 or PP escutcheons for "light hazard" only, while FM limits use for same hazard with F2 escutcheon only Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate0) Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate't Electroless Nickel PTFE(Teflon®)*(7) Electroless Nickel PTFE (Teflon®)" Bright Brass Bright Brass3 Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint126 Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed 'corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. cULus listed Corrosion Resistant Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. "DuPont Registered Trademark 7. IMPERIAL MAX REC. LOAD LBS. METRIC* PIPE ROD PIPE I ROD 1/2 3/8 400 10 3/4 400 20 to 1 3/8 400 m to 11/4 3/8 400 32 10 11/2 3/8 400 1 40 10 2 3/8 400 50 10 21/2 3/8 600 65 10 3 3/8 600 80 10 31/2 3/8 600 10 4 1000 100 10 5 1250 125 12 6 1250 150 12 8 1/2 1250 200 1 12 * Order Part #300m Note: 1/2" Ring Hanger not <FM> approved S Fcn 300 RING HANGER [1 ze A)US I thru 4 inch pipe 112 and 314 Inch pipe 5 thru 8 Inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 specification. FINISH - Mil. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H-1 71(Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 6500F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - 1 thru 4 inch: * Offset edge for EASY pipe insertion. 1 thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru 3 inch: * UL listed to accept AFCON#3 10 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index F- 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in linch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. WOOD r&irni Mount) Use #14 Nut Driver (Item #100) Item# Model Shk Lgth Shk Dia Box Qty ht (per 100) Case Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 GST 100 1 1/4 100 5.00 1000 22 GST 200 2 1/4 100 6.50 1000 23 IGST300 3 1/4 100 7.50 1000 24 GST 600 6 1/4 50 9.00 500 S WOOD - Sammys I lI i #14 (Item #100-black) Sammys 114,3/8" rod WOODII im LI rimiTi Use #14 Nut Driver (Item #100) Approvals Item# Model Shk Lgth Shk Dia FMTest Loa lb. ULTest Load lb. UIJFM Pipe Size Actual Pullout Box Qty 10 - * 27 GST.75 3/4 1/4 564#-6Ply 100 NFPA 11 GST10 1 1/4 210# - 7/16 670# - 3/4"OSB Ply 100 IUL-FM-NFPA 12 GST2O 2 1/4 940# 850# 3/4-2 1/2 1760# -Fir 100 UL-NFPA GST25-380 2 1/2 3/8 1500# 4 2113# -Fir 50 UL-FM-NFPA 13 GST3O 3 1/4 1475# 1500# 3/4-4 2060# -Fir 100 NFPA 403 GST4O 4 1/4 2180# -Fir 50 NFPA 14 jGST60 1 6 1 1/4 1 2230# - Fir 50 #I4SW (Item #101-red) Sidewinders & Sammys 1/2" rod IWOOD I4II II! tl!flfltI LI rrnTlm Use #14SWNutDriver(Item #101) Item# Model ShkLgth ShkDia ActualPullout BoxQty Weight (per 100) Case Qty 8 GST2 2 1/4 1760# - Fir 50 7.00 500 *06 CST 2.5-380 21/2 3/8 2113#-Fir 50 10.00 500 15 GST3 1 3 1 1/4 2275# - Fir 50 1 10.50 500 16 JGST4 1 4 1 1/4 1 2180#-Fir 50 1 10.60 500 17 JGST6 1 6 1 1/4 1 2230# - Fir 50 1 10.95 500 Not less than 2" nominal width <(1112) a NE q Wood Joist TJI Joist/ Truss Consult truss manufacturer for recommended installation point. 5Pre..drilling may be required for items #27 and #06. Tools available on page 9. I—] Double Sheetrock Ceiling Minimum 2" imbedment into base material for NFPA 13 compliance For vertical use. Install in center of lowerface. Page 4 Note: Screwsmustbe installed with appropriate nut driver to comply with warranty I[OII]VEIiL1mrl : m1nurimm Use #14SW Nut Driver (Item #101) Item# Model 1ShkLgth I ShkDia Actual I Box Qty I Weight Case*' IShear/Pullout (per 100) 4016 SWG100 1 1/4 I 100 750 I 1000 300 SWG200 2 1/4 17254-Fir 100 8.00 1000 WOOD - 3/ Rod tl i m'(InIn I rrnnn Use #I4SW Nut Driver (Item #101) Approvals Item # Model Shk Lgth Shk Dia II Test UI/FM ActualBox Qty Weight Load lb. Pipe Size Shear/Pullout (per 100) - 18 SWGIO 1 1/4 100 6.00 UL•NFPA 19 SWG20 2 1/4 1250# 3 1725# - Fir 100 7.00 UL•NFPA * 26 SWG25-380 2 1/2 3/8 15004 4 2249# -Fir 50 10.25 - 25 ISWG30 1 3 1/4 50 1 8.50 S #I4SW (Item #101-red) Sidewinders & Sammys 1/2" rod Prestressed Concrete Page 5 WOOD —Sidewinders Not less than 2" nominal width (1112") up to3l/2" pipe; not less than 3" nominal I.- width 4" & 5" pipe Floor Joist r I -- TJI Joist! Truss Consult truss manufacturer for recommended installation point *pre_drilling may be required for item #26. Tools available on page 9. rnstaiiation perNFPA 13J L-1 IL Minimum 2 1/2" from bottom for branch lines. Minimum 3" from bottom for main lines. Exception: I This requirement shall not apply to 2" or thicker nailing strips resting SHEETROCK -Toggle on top of steel beams. SHEETROCK - 1/4" Rod (Vertical Mount) Use #14 Nut Driver (Item #100) Item# Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight Case Qty (per 100) 71 SST 300 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock #14 (Item #100-black) Sammys 1/4", 3/8" rod 'Use #14 Nut Driver (Item #100) Item# Model Shk Lgthl Shk Dia Actual Pullout Pkg Qty Weight Case Qty (per 100) 70 ISST30 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock Note: Screws must be installed with appropriate nut driver to comply with warranty