HomeMy WebLinkAbout1959 PALOMAR OAKS WAY; 300; FPC2018-0363; PermitPERMIT REPORT
tr3ity of
Carlsbad
Print Date: 12/16/2021
Job Address: 1959 PALOMAR OAKS WAY, # 300,
Permit Type: FIRE-Construction Commercial
Parcel #: 2130922600
Valuation: $727,834.99
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Project Title:
Description: LABYRINTH -SPRINKLER TI (134 HEADS)
CARLSBAD, CA 92011-1310
Work Class: Fire Sprinklers
Track #:
Lot #:
Project #:
Plan #:
Construction Type:
Orig. Plan Check #:
Plan Check #:
Permit No: FPC2018-0363
Status: Closed - Finaled
Applied: 11/05/2018
Issued: 11/27/2018
Finaled Close Out: 02/04/2021
Inspector:
Final Inspection:
Applicant: FPContractor:
TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC
JOHN CAPUTO 1611 S MELROSE PL, #244
1611A S MELROSE DR VISTA, CA 92081-5471
VISTA, CA 92081-5407 (760) 525-4329
(760) 525-4329
FEE AMOUNT
FIRE NFPA 13 or 13R System> 100 heads $654.00
Total Fees: $654.00 Total Payments To Date: $0.00 Balance Due: $654.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov
0 C 0 T-(DQ N N LO 's)-- 0
CO
C C
TrFeP >.-
C,,'
CO035
0<'
MATERIAL DATA SUBMITTAL CNI
)a)
U.
Labyrinth
1959 Palomar Oaks Way *300
Carlsbad, CA 92009
Page * Description Manufacturer
1-2 Pipe Allied Dyna-Thread Pipe
- 3-10 Fittings Tyco Ductile Iron Fittings
11-12 Mechanical Tee Tyco Fig 40-5 Strap Tee
13-19 Sprinkler Reliable F1FR56 Sprinkler
20-23 Sprinkler Reliable G5-56 Sprinkler
24 Hanger Afcon Fig. 300 Ring Hanger
25 Hanger Afcon Fig 655 All Thread Rod
26-27 Attachment Sammy Wood Vertical Mount
Total Fire Protection, Inc.
1611 A S. Melrose Dr. *244
Vista, CA 92081
(760)525-4329 fax (877) 724-4329
C16-955387
DynamThread 0
S Full Line Sch-40 Replacement
Dyna-Thread' offers the life expectancy of Sch4O with superior hydraulics and greater value.
Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety
and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages.
Comparison to Schedule 40 Comparison to L.W.T. Pipes
S
Dyna-Thread's inside diameter is up
to 3.6% larger than Sch-40 giving it
superior hydraulics. And, when used
in combination with Dyna-Flow pipe,
down sizing often occurs.
Dyna-Thread is fully listed and
approved by UL, ULC, and FM for
fire sprinkler applications.
The life expectancy of Dyna-Thread
and Sch40 are equal based on the
calculated wall thicknesses per UL.
The consistent quality of steel used to
make Dyna-Thread facilitates smooth
threading and lower maintenance
costs.
The exterior of Dyna-Thread is
protected by a clean, durable mill
coating for extended shelf life and
easy paint application.
(9 <~> @
Listed Approved Listed
With its increased strength and lighter
weight, Dyria-Thread reduces
installation fatigue and is ideal for
retro-fit applications.
Corrosion Resistance Ratio (CRR) is a
UL (Underwriters Laboratory) term for
the estimated life expectancy of a pipe
joint. This is based on the calculated
wall thickness at the base of the first
exposed thread, assumed to be the
weakest point of the pipe length. Dyna-
Thread and Sch-40 have the same
calculated wall thicknesses at this point
and are both assigned the same CRR of
1.00.
The internal surface of all black Allied
Tube & Conduit Fire Sprinkler pipe
products up to 4.5000" in diameter is
coated with our new Antibacterial
Formula, "ABF". In scientific laboratory
test, ABS proved to have superior
resistance to microbial colonization of
pipe walls, thereby delaying or possibly
preventing the onset of
Microbiologically Influenced corrosion
(MIC) when the First Sprinkler System
is first installed.
More wall thickness at the thread
(CRR=l .00) gives Dyna-Thread
better life expectancy than lightwall
threadable pipe joints.
Unlike lightwall threadable pipe,
Dyria-Thread has no thread gauge
warning.
Dyna-Thread is approved for
standard hanger spacing (15 ft.
O.C.), can be used as earthquake
sway bracing, and is safe to use as
drops.
Dyna-Thread is safer to weld on.
Dyna-Thread is more widely
accepted than lightwall threadable
where Sch-40 is specified.
Super 40/Dyna-Thread pipe is
manufactured to meet: ASTM A-135,
Grade A and is in compliance with
NFPA- 13. All sizes of Super 40fDyna-
Thread are rated at 300 psi working
pressure. Super 40/Dyna-Thread is UL
and ULC Listed for wet, dry deluge and
pre-action sprinkler systems and FM
Approved for use in wet systems. Super
40/Dyna-Thread can be "hot-dip"
galvanized to meet FM requirement for
dry systems. Super 40/Dyna-Thread is
approved for all threaded couplings and
welded outlets and is suitable for all
roll-grooved, and plain-end fittings.
(See listing information).
Specifications
NPS Nominal I.D. Wt. Wt, (H20 Filled) Pcs/ Wtil.itt (21') Wtjtltt (24') WI/lilt (25')
In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg
1.080 1.330 1.75 70 1955 2234 232
25 27.4 2.0 2.60 70 887 1013 1051
11/4, 1.408 1.870 2,54 51 2002 2288 2384
32 35.8 2.8 3.78 51 908 1038 108
1W 1.639 2.290 3.22 44 2115 2418 2519
40 41.6 3.4 4.79 44 959 1097 114.
2.104 3.050 4.57 30 1921 2196 228
50 53.4 4.5 6.80 30 871 996 103
dhed
16100 S. Lathrop• Harvey, IL 60426 tqco/FlowControl ') 11350 Norcom Rd. • Philadelphia, PA 19154
TUBE& CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009
Customer Service: 1 (800) 882-5543
Fax 708-339-1806
S3-3
Submittal Data Sheet Dyna Threadn
S Full Line Sch-40 Replacement
Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler
pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with
quality and superior hydraulic advantages.
Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than
Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow
pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC,
and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40
are equal based on the calculated wall thicknesses per UL. The consistent quality of
steel used to make Dyna-Thread facilitates smooth threading and lower maintenance
costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for
extended shelf life and easy paint application. With its increased strength and lighter
weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications.
Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the
estimated life expectancy of a pipe joint. This is based on the calculated wall thickness
at the base of the first exposed thread, assumed to be the weakest point of the pipe
length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this
point and are both assigned the same CRR of 1.00.
Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=l .00) gives
Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike
lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is
approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway
bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc-
coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than
lightwall threadable where Sch40 is specified.
Stamp Here
S Specifications & Approvals Super 40/
Dyna-Thread pipe is manufactured to
meet: ASTMA 135, Grade and is in
compliance with NFPA-13. All sizes of
Super 40fDyna-Thread are rated at 300
psi working pressure. Super 40/ Dyna-
Thread is UL and ULC Listed for wet,
dry and pre-action sprinkler systems and
FM Approved for use in wet systems.
Super 40fDyna-Thread can be "hot-dip"
galvanized to meet FM requirement for
dry systems. Super 40/Dyna-Thread is
approved for all threaded couplings and
welded outlets and is suitable for all roll-
grooved, and plain-end fittings. (See
listing information).
The internal surface of all black Fire
Sprinkler pipe up to 4.5000" in diameter
shall be coated with Allied Tube &
Conduit Antibacterial Formula "ABF".
Specifications
NPS Nominal I.D. WI. WI. (H20 Riled) Pcsl Wt/Lift (21') Wtil.lft (24*) WIll-lU (25')
In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg
1.080 1.330 1.75 70 1955 2234 2327
25 27.4 2.0 2.60 70 887 1013 105
11/4' 1.408 1.870 2.54 51 2002 2288 2384
32 35.8 2.8 3.78 51 908 1038 1081
1h/2 1.639 2.290 3.22 44 2115 2418 251
40 41.6 3.4 4.79 44 959 1097 114
2.104 3.050 4.57 30 1921 2196 228
50 53.4 4.5 6.80 30 871 996 1034
American Tube and Pipe was acquired by Allied Tube and Conduit on February 1,
1997. The engineered lightwall and standard wall family of products although they
have different names are the same in all respects with regard to strength, weight,
bundle count, listings and approvals. For example,
Dyna-Flow and Super Flo are the same product as
are Dyna Thread and Super 40. XL is manufactured Us L
with Exterior galvanized coating. BLT is (@ 9
manufactured with Black lacquer coating. Listed Approved Listed
Project: Sprinkler Contractor: Date:
5 Engineer: Specification Reference: System Type:
Locations: Comments:
S3-4
S tqC0 Fire & Building
IProducts
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500
S
Pipe Fittings
NPT Threaded,
Ductile Iron
General
Description
The TycoO Series 800 Threaded Pipe
Fittings and California Tees & Elbows
are manufactured from ductile iron.
They are stronger and more corrosion
resistant than cast iron fittings. The
additional strength is provided by the
ductile properties and by adding mag-
nesium while the iron is being poured
into the final cast shape. Although
lighter than standard cast iron, the fit-
tings have an added advantage of be-
ing less susceptible to cracking due to
their added strength.
The Series 800, California, and Figure
719 Threaded Pipe Fittings are a re-
designation for the Central Series 800,
California, and Figure 719 Threaded
Pipe Fittings.
WARNINGS
The Threaded Pipe Fittings described
herein must be installed and main-
tained in compliance with this docu-
ment, as well as with the applicable
standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing jurisdiction. Failure to do so may
impair the performance of these
devices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
Technical
Data
Approvals:
UL Listed and FM Approved
Maximum Working Pressure:
Series 800 and California Fittings
250 psi (17,2 bar)
Figure 719 Plug:
250 psi (17,2 bar)
Page 1 of 10
Material:
Series 800 and California Fittings:
Ductile Iron
Figure 719 Plug:
Cast Iron
Pipe Thread:
NPT per ANSI B1.20.1
Installation
Apply Teflont tape or high quality pipe
joint compound on male pipe threads
and tighten two to three turns beyond
hand tight.
NOTE
Installers who have not used ductile
iron threaded fittings should be in-
structed that the fittings are stron-
ger than the pipe and overtightening
the fitting can create leaks and cause
damage to pipe threads. In general,
there Is about one-half turn difference
between cast iron and ductile iron fit-
tings. Apply Teflon tape or high qual-
ity pipe joint compound on the male
pipe threads and tighten two to three
turns beyond hand tight. If an auto-
matic make-on machine is being used,
please exercise caution in setting the
machine to the proper parameters pri-
or to tightening fittings onto the male
pipe threads.
Limited
Warranty
Products manufactured by Tyco Fire
& Building Products (TFBP) are war-
ranted solely to the original Buyer for
ten (10) years against defects in mate-
rial and workmanship when paid for
and properly installed and maintained
under normal use and service. This
warranty will expire ten (10) years from
date of shipment by TFBP. No warran-
ty is given for products or components
manufactured by companies not af-
filiated by ownership with TFBP or for
products and components which have
been subject to misuse, improper in-
stallation, corrosion, or which have not
been installed, maintained, modified or
repaired in accordance with applicable
JANUARY, 2008
Standards of the National Fire Protec-
tion Association, and/or the standards
of any other Authorities Having Juris-
diction. Materials found by TFBP to be
defective shall be either repaired or re-
placed, at TFBP's sole option. TFBP
neither assumes, nor authorizes any
person to assume for it, any other ob-
ligation in connection with the sale of
products or parts of products. TFBP
shall not be responsible for sprinkler
system design errors or inaccurate or
incomplete information supplied by
Buyer or Buyer's representatives.
In no event shall TFBP be liable, in
contract, tort, strict liability or under
any other legal theory, for incidental,
indirect, special or consequential dam-
ages, including but not limited to labor
charges, regardless of whether TFBP
was informed about the possibility of
such damages, and in no event shall
TFBP's liability exceed an amount
equal to the sales price.
The foregoing warranty is made In lieu
of any and all other warranties, ax-
cress or implied, including warranties
of merchantability and fitness for a
particular curcose.
This limited warranty sets forth the ex-
clusive remedy for claims based on
failure of or defect in products, materi-
als or components, whether the claim
is made in contract, tort, strict liability
or any other legal theory.
This warranty will apply to the full ex-
tent permitted by law. The invalidity,
in whole or part, of any portion of this
warranty will not affect the remainder.
Ordering
Procedure
When placing an order, indicate the
full product name. Please specify the
quantity, figure number, wall thickness,
and size.
tregistered trademark of E. I. du Pont de Nemours and Company or Its affiliates.
TFPI7IO
Page 2of 10 TFPI7I0
Nominal Pipe Figure 813 Size
ANSI A Approx.
Inches Inches Weight Part
DN (mm) Lbs. Number
(kg)
1/2 1.13 0.22 86780 0N15 (28,7) (0,09)
3/4 1.31 0.33 86781 DN20 (33,3) (0,15)
1 1.50 0.48 86280 0N25 (38,1) (0,21)
1-1/4 1.75 0.73 86281 DN32 (44,5) (0,33)
1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42)
2 2.25 1.55 86283 0N50 (57,1) (0,70)
2-1/2 2.69 2.70 86782 0N65 (68,3) (1,22)
0
01
_
B"
FIGURE 811 FIGURE 813
900 ELBOW 450 ELBOW
TABLE I
NOMINAL DIMENSIONS FIGURES 811 & 813
Figure 811
B Approx. A B
Inches Weight Part Inches Inches
(mm) Lbs. Number (mm) (mm) (kg)
0.56 0.24 86206 0.88 0.38
(14,2) (0,11) (22,4) (9,7)
0.75 0.40 86205 1.00 0.44
(19,0) (0,18) (25,4) (11,2)
0.81 0.64 86200 1.13 0.81
(20,6) (0,29) (28,7) (20,6)
1.06 0.95 86201 1.31 0.63
(26,9) (0,43) (33,3) (16,0)
1.19 1.24 86202 1.44 0.69
(30,2) (0,56) (36,6) (17,5)
1.50 1.74 86203 1.68 0.94
(38,1) (0,79) (42,7) (23,9)
1.56 3.28 86204 1.94 1.00
(39,6) (1,49) (49,3) (25,4)
TFPI7IO Page 3 of 10
FIGURE 812
90° REDUCING ELBOW
Nominal Pipe Figure 812 Size
ANSI A B C D Approx.
Weight Part Inches Inches Inches Inches Inches Lbs. Number DN (mm) (mm) (mm) (mm) (kg)
3/4x1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20x15 (30,2) (30,2) (16,0) (16,0) (0,15)
1 x 1/2 1.25 1.38 0.56 0.81 0.44 86210 DN25 x 15 (31,8) (35,1) (14,2) (20,6) (0,20)
1 x314 1.38 1.44 0.69 0.88 0.53 86211 DN25 x 20 (35,1) (36,6) (17,5) (22,4) (0,24)
1-1/4x1/2 1.31 1.50 0.63 0.94 0.64 86212 DN32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29)
1-1/4 x 3/4 1.44 1.63 0.75 1.06 0.75 86213 DN32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34)
1-114x1 1.56 1.68 0.88 1.00 0.77 86214 DN32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35)
1-1/2 x 3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40 x 20 (38,1) (44,4) (19,0) (30,2) (0,43)
1-1/2 x 1 1.63 1.81 0.88 1.13 0.99 86215 DN40 x 25 (41,4) (46,0) (22,4) (28,7) (0,45)
1-112x1-1/4 1.81 1.88 1.13 1.19 1.14 86216 DN40x32 (46,0) (47,8) (28,7) (30,2) (0,52)
2x3/4 1.63 1.94 0.88 1.38 1.39 86217 DN50 x 20 (41,4) (49,3) (22,4) (35,1) (0,63)
2x1 1.75 2.06 2.00 1.31 1.58 86218 DN50x25 (44,4) (52,3) (50,8) (33,3) (0,72)
2 x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50x40 (50,8) (55,6) (31,8) (36,6) (0,76)
2-1/2 x 2 2.38 2.63 1.25 1.88 3.01 86262 DN65 x 50 (60,5) (66,8) (31,8) (47,8) (1,36)
TABLE 2
NOMINAL DIMENSIONS FIGURE 812
(D
0
TFPI7I0 Page 5of 10
'fl
FIGURE 814 FIGURE 818
IRON TEE STRAIGHT COUPLING
Nominal Pipe
TABLE 4
NOMINAL DIMENSIONS FIGURES 814 & 818
Figure 814 Figure 818 Size
A B Approx. A B ANSI Inches Inches Inches Weight Part Inches Inches DN (mm) (mm) Lbs. Number (mm) (mm) (kg)
1/2 1.13 0.56 0.33 86340 1.38 0.31
DNI5 (28,7) (14,2) (0115) (35,1) (1,9)
3/4 1.31 0.75 0.50 86341 1.63 0.56
DN20 (33,3) (19,0) (0,23) (41,4) (14,0)
1 1.50 0.81 0.85 86230 1.75 0.38
0N25 (38,1) (20,6) (0,38) (44,4) (9,7)
1-1/4 1.75 1.06 1.30 86231 2.00 0.56
DN32 (44,4) (26,9) (0,59) (5018) (14,0)
1-1/2 1.94 1.19 1.63 86232 2.19 0.75
IDN40 (49,3) (30,2) (0,74) (55,6) (19,0)
2 2.25 1.50 2.63 86233 2.63 1.13
0N50 (57,1) (3811) (1,19) (66,8) (28,7)
2-1/2 2.69 1.56 4.55 86234 3.00 0.75
DN65 (68,3) (39,6) (2,06) (76,2) (19,0)
Approx.
Weight Part
Lbs. Number
(kg)
0.18 72779 (0,08)
0.26 72778 (0,11)
0.44 72755 (0120)
0.54 72754 (0,24)
0.71 72753 (0,32)
1.15 72752 (0,52)
2.29 12758 (1,04)
0
TFPI7I0 Page 6of1O
U
S
Page 7 of 10 TFPI7IO
FIGURE 815
REDUCING TEE
Nominal Pipe Size Figure 815
A B C D E F ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part
DN Lbs. (mm) (mm) (mm) (mm) (mm) (mm) Number
(kg)
1-1/2x1-1/4x112 1.44 1.31 1.69 0.69 0.63 1.13 1.03 86257 DN40x32x15 (36,6) (33,3) (42,9) (17,5) (16,0) (28,7) (0,47)
1-1/2x1-1/4x3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 86258 DN40x32x20 (38,1) (36,6) (44.5) (19,0) (19,0) (30,1) (0,50)
1-1/2x1-1/4x1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 0.6.259 DN40x32x25 (41,4) (39.7) (46,0) (22,4) (22,4) (28,7) (0,59)
1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 86260 DN40x32x50 (55,6) (54,1) (50,8) (36,6) (36,6) (57,1) (0,88)
1-1/2x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 86261 DN40x40x15 (36.6) (36,6) (42,9) (17,5) (17,5) (28.7) (0.52)
1-1/2x1-1/2x314 1.50 1.50 1.75 0.75 0.75 1.19 1.23 86262 DN40x40x20 (38,1) (381) (44,4) (19,0) (19,0) (30,1) (0.56)
1-112x1-112x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 86263 0N40 x 40 x 25 (41,2) (41,2) (46,0) (22,4) (22,4) (28,7) (0,62)
1-1/2x1-1/2x1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 86264 DN40 x 40 x 32 (46,0) (46,0) (47,6) (27,0) (27,0) (30,1) (0,68)
1-1/2x1-1/2x2 2.19 2.00 1.44 1.44 1.25 2.00 86265 DN40 x 40 x 50 (55,5) (50,8) (36,6) (36,6) (31,7)
2 xl x 2
t2.25
2.00 2.25 1.50 1.31 1.50 2.18 86266 DNSO x 25 x 50 (50,8) (57,2) (38,1) (33,3) (38,1) (0.99)
2x1-114x2 2.13 2.25 1.50 1.44 1.50 2.3186267 DN50x32x50 (54,1) (57,2) (38,1) (36,6) (38.1) (1,05)
2x1-1/2x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 DN50 x 40 x 15 (47.8) (19,0) (17.5) (33,3) (0,68)
2x 1-112x314 1.63 1.94 0.88 0.75 1.38 1.61 86269 DN50 x 40 x 20 (41,4)1) (49,3) (22,4) (19.0) (35,0) (0,73)
2x1-112x1 1.75 2.00 1.00 0.88 1.31 1.65 86270 DN50 x 40 x 25 (44,5)) (50,8) (25.4) (22,4) (33,3) (0,75)
2x1-1/2x1-1/2 2.06 2.19 1.31 1.19 1.44 2.03 86272 DN50 x 40 x 40
(38,1)V366)
(52.4)2) (55,5) (33,3) (30,2) (36,6) (0,92)
2x1-1/2x2 2.25 2.50 1.50 1.44 1.50 2.37 86273 DN50x40x50 (57,1)5) (63,5) (38,1) (36,6) (38,1) (1.07)
2x2x1/2 1.50 0 1.88 0.75 0.75 1.31 1.50 86222 DN50x50x15 (38,1)1)(47,8) (19,0) (19,0) (33,3) (0.68)
2x2x314 1.63 3 1.94 0.88 0.88 1.38 1.67 86223 DN50x50x20 (41,4) ) (49,3) (22,4) (22.4) (35,0) (0,76)
2x2x 1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 86224 0N50 x 50 x 25 (44,5) (44.5) (50,8) (25,4) (25,4) (33,3) (0,86)
2x2x1-114 1.88 1.88 2.13 1.13 1.13 1.44 2.05 86225 DN50 x 50 x 32 (47,8) (47,8) (54,1) (28,7) (28,7) (36.6) (0,93)
2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 86226 DN50x50x40 (50,8) (50,8) (55.6) (31,8) (31,8L (38,1) (0,96)
2 x 2 x 2-1/2 2.63 2.63 2.38 1.75 1.88 1.44 3,67 86227 0N50 x 50 x 65 (66.8) (66.8) (60,5) (44,5) (47.8) (36.6) (1,66)
2-1/2 x 2 x 3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 86274 DN65x50x20 (44,5) (41,4) (58,7) (15,9) (22,4) 1 (44,5) 1 (1,01)
TABLE 5(2 0F2)
NOMINAL DIMENSIONS FIGURE 815
S
Page 8 of 10 TFPI7IO
11TT'!,
j flhlll
FIGURE 820
CAP
FIGURE 830
BRASS SEAT UNION
FIGURE 719
PLUG
Nominal Pipe Figure 820 Figure 830 Figure 719 Size
ANSI A Approx. A B Approx. A Approx.
Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part
DN (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number
(kg) (kg) (kg)
1/2 0.88 0.15 72776 1.88 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0,06) (47,8) (20,6) (0,21) (23,9) (0,04)
3/4 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 DN20 (25,4) (0.10) (50,8) (23,9) (0,30) (28,7) (0.08)
1 1.18 0.33 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 DN25 (30,0) (0,15) (55,6) (20.6) (0,49) (31,7) (0,13)
1-1/4
0N32
1.31
(33,3)
0.54
(0,24) 72756 2.50
(63,5)
1.06
(26,9)
1.54
(0,70) 86277 1.38
(35,1)
0.50
(0,23)
86295
1-1/2
DN40
1.38
(35,1)
0.68
(0,31) 72822 2.63
(66,8)
1.19
(30,2)
2.03
(0,92) 86278 1.44
(36,6)
0.70
(0,32)
86296
2
0N50
1.50
(38,1)
0.96
(0,43) 72823 3.13
(79,5)
1.63
(41,4)
3.15
(1,43) 86279 1.50
(381)
0.90
(0,41)
86297
2-1/2 1.75 1.80 72825 - - - - - - - DN65 (44,5) (0,82)
TABLE 6
NOMINAL DIMENSIONS FIGURES 820,830 & 719
S
TFPI7I0 Page 9of 10
S
IAJ I _
FIGURE 825 FIGURE 827 FIGURE 816
EXTENSION PIECE HEX BUSHING REDUCING COUPLING
TABLE 7
NOMINAL DIMENSIONS FIGURE 825,827 & 816
Nominal Pipe Figure 825 Figure 827 Figure 816
Size Extension Piece Hex Bushing Reducing Coupling
A Approx. A Approx. A B Approx.
ANSI Inches Inches Weight Part Inches Weight Part Inches Inches Weight Part
DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number
(kg) (kg) (kg)
1/2x1/2 1.50 0.20 72751 - - - - - - - DN15 x 15 (36,1) (0,09)
112x1/2 2.00 0.27 72980 - - - - - - - DN15 x 15 (50,8) (0,12)
3/4x3/4 1.50 0.22 72981 - - - - - - - DN20x20 (38,1) (0,10)
3/4 x 3/4 2.00 0.31 73982 - - - - - - - DN20 x 20 (50,8) (0,14)
3/4 x 1/2 1.75 0.69 0.38 86772 DN20 x 15 - - - (43,2) (17,5) (0,17)
1 x 1/2 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25x 15 - - - (26,9) (0,10) (42,9) (12,7) (0,17)
1 x3/4 1.06 0.18 72762 1.75 0.50 0.53 86229 DN25x20 - - (26,9) (0,08) (43,2) (12,7) (0,24)
1-1/4x1
- -
1.19 0.31 72763 - - - - DN32x25 (30,2) (0,14)
1-1/2x1
- -
1.25 0.53 72757 - - - - DN40 x 25 (31,7) (0,24)
1-1/2x1-1/4
- -
1.25 0.35 72764 - - - - DN40x32 (31,7) (0,10)
2x1
- -
1.38 0.75 72759 - - - - DNSO x 25 (35,1) (0,34)
2 x 1-1/4
- - -
1.38 0.69 72761 - - - - DN50x32 (35,1) (0,31)
2x1-1/2
- --j
1.38 0.62 72775 - - - - DN50 x 40 (35,1) (0,28)
tqC0 Fire & Building
IlProducts
Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500
www.tyco-fire.com
Grinnell Grooved Fire Protection Products
Figure 40-5
Strap
S
General
Description
Usting/Approval InIormaton
The Figure40-5 Strap isaneconomicalalternative
to welded pipe outlets on steel pipe.
The Figure 40-5 Strap may be used with full
lengths of pipe and eliminates threading and
welding, decreasing waste and installation time.
The 40-5 Strap may be used in wet, dry pipe and
deluge systems.
WARNING
The Figure 40-5 Strap described herein must be
installed and maintained in compliance with this
document, as we/las withtheapplica ble standards
of the National Fire Protection Association, in
addition to the standards of anyotherauthorities
ha ving jurisdiction. Failure to do so mayimpair
the performance of this device.
The owner is responsible for maintaining their
fire protection system and devices in proper
operating condition. The installing contractor or
sprinkler manufacturershou/dbe contacted with
any questions.
Technical
Data
Figure: 40-5
Outlet: Threaded
Approvals: UL, FM, ULC, and VdS;
See Fire Protection Submittal Sheet for exact
Listing /Approval information.
Page 1 of 2
Housing: Ductile iron conforming to
ASTM A-536, Grade 65-45-12
Protective Coatings:
Clear rust inhibitive coating
Zinc electroplated conforming to
ASTM B-633, Type Ill Service 2 (optional)
U-Bolt: Carbon steel conforming to
ASTM A-307, Grade A, Zinc electroplated
Nuts: Carbon steel conforming to
ASTM A-307, Grade A, Zinc electroplated
Gasket: (specify when ordering)
Grade "E" EPDM green color code.
(See Data Sheet 1FP1895 for aid in selecting
proper gasket)
Ordering
Procedure
When placing an order, indicate the full product
name. Please specifythe quantity, figure number,
type of gasket, Grade "E" EPOM, and size.
Grinnell Grooved Piping Products, valves,
accessories and other products are available
throughoutihe U.S., Canada, and internationally,
through a network of distribution centers. You
may write directly or call 215-362-0700 for the
distributor nearest you.
Care and
Maintenance
The owner is responsible for the inspection,
testing, and maintenance of their fire protection
system and devices in accordance with the
applicable standards of the National Fire Protection
Association (e.g., NFPA 25), in addition to the
standards of any authority having jurisdiction.
The installing contractor or product manufacturer
should be contacted relative to any questions.
Any impairment must be Immediately corrected.
It is recommended that automatic sprinkler
systems be inspected, tested, and maintained by
a qualified Inspection Service.
September 2004
Limited
Warranty
Products manufactured by Tyco Fire Products are
warranted solely to the original Buyer for ten (10)
years against defects in material and workmanship
when paid for and properly installed and maintained
under normal use and service. This warranty will
expire ten (10) years from date of shipment by Tyco
Fire Products. No warranty is given for products or
components manufactured by companies not
affiliated byownershipwfthlyco Fire Products orfor
products and components which have been subject
to misuse, improperinstallation, corrosion, orwhich
have not been installed, maintained, modified or
repaired in accordance with applicable Standards of
the National Fire Protection Association (NFPA),
and/or the standards of any otherAuthorkiesHaving
Jurisdiction. Materials found by Tyco Are Products
to be defective shall be either repaired or replaced, at
Tyco Fire Products' sole option. Tyco Are Products
neither assumes, nor authorizes any person to
assumefor, any other obligation inconnectionwifh
the sale of products or parts of products. Tyco Fire
Productsshallnotberesponsibleforsprinklersystem
designerrorsorinaccurateorincompletelnfonnation
supplied by Buyer or Buyers representatives.
IN NO EVENT SHALL TYCO FIRE PRODUCTS BE
LIABLE, IN CONTRACT, TORT, STRICT LIABILITY
OR UNDER ANY OTHER LEGAL THEORY, FOR
INCIDENTAL, INDIRECT, SPECIAL OR
CONSEQUENTIALDAMAGES, INCLUDING BUTNOT
LIMITED TO LABOR CHARGES, REGARDLESS OF
WHETHER1YCOFIREPRODUCTSWAS INFORMED
ABOUT THE POSSIBILITY OF SUCH DAMAGES,
AND IN NO EVENTSHALL TYCO FIRE PRODUCTS'
LIABILITY EXCEED AN AMOUNT EQUAL TO THE
SALES PRICE.
THE FOREGO&V WARR4NT(ISM4OEWLIEUOt
ANYANO ALL OTHER WARR4NI9S EXPRESS OR
(B
TFPI72O
Pipe Nominal Dimensions Hole Net
Size Size Wt. A B C D
Run Inches Inches Inches Inches Inches Lbs.
Branch mm mm mm mm mm Kg.
11/4 X /2° 2.00 1.50 3.50 1.20 1/ie 0.84
50.8 38.1 88.9 30.5 30.2 0.4
11/4" X3/4" 2.00 1.50 3.50 1.20 1/I6 0.88
50.8 38.1 88.9 30.5 30.2 0.4
1/4°X i 2.31 1.68 3.50 1.20 1/i 1.13
58.7 42.7 88.9 30.5 30.2 0.5
11/20 X 1/2I 2.12 1.62 3.50 1.32 1/16 0.84
53.8 41.1 88.9 33.5 30.2 0.4
11/2 3/40 2.12 1.62 3.50 1.32 1/16 0.88
53.8 41.1 88.9 1 33.5 30.2 0.4
11/20 X 14 2.43 1.80 3.50 1.32 1/i 1.13
61.7 45.7 88.9 33.5 30.2 0.5
20x'/2' 2.36 1.86 3.74
-_95.0
1.55 1/i 0.88
59.9 47.2 39.4 30.2 0.4
2"X3/40 2.36 1.86 3.74 1.55 1/i 0.95
59.9 47.2 95.0 39.4 30.2 0.4
2" P 2.67 2.04 3.74 1.55 1/t 6 1.16
67.8 51.8 95.0 39.4 30.2 0.5
21/2" X 1/20 2.61 2.11 4.25 1.80 1/16 0.90
66.3 53.6 108.0 45.7 30.2 0.4
21/2" X3/4° 2.61 2.11 4.25 1.80 1/I6 0.99
________ 66.3 53.6 108.0 45,7 30.2 0.4
2'/2' x i' 2.92 2.29 4.25 1 1.80 1/16 1.21
74.2 58.2 108.0 45.7 30.2 0.5
Item Description
1 Housing
2 Gasket
3 Flanged Nut
4 U-Bolt
Fitting
Size
Equivalent Length
(1 inch pipe)
11/40 X V. 8
1V20 X 1" 6
20 x 1' 6
21/20 x 1 4
The friction loss for these outlets is specified in
equivalent length of 1 inch Schedule 40 (C=120) pipe.
Page 2012 TFP1 720
Figure 40-5 Strap
The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact
directly to a sprinkler. These fittings should be used Tyco Fire Products.
for hydraulically calculated systems only.
12 ,e
General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001
instructions ((H-i 000). Never remove any piping component or correct or modify any piping deficiencies without
first depressurizing and draining the system. Material and gasket selection should be verified to be compatible
for the specific application. . Certified Company
TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A.
Upright Pendent
Vertical Sidewall Horizontal Sidewall
Recessed Concealed
Horizontal Sidewall Pendent
Bulletin 014 Rev. L
liable Model Fl FR Series
Quick Response
Standard Spray
C
C
Model Fl FR56 Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall El
Model Fl FR56 Recessed Sprinkler Types
Standard Pendent/F1/F2/FP
Horizontal Sidewall
Model Fl FR56 Concealed Sprinkler Types
Standard Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler
Types
Standard Upright
Standard Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Recessed
Sprinkler Types . Standard Pendent
Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler
Types*
Standard Pendent
Less than 0.25% Lead Content
Listing & Approvals
Underwriters Laboratories Inc. and Certified for
Canada (cULus).
Factory Mutual Approvals (FM)
Loss Prevention Council (LPCB, UK)
VdS Schadenverhutung GmbH
*NSF Certified to NSF/ANSi Standard 61 Annex G
EC Certificate: 0786-CPD-40239 (RA1414), 0786-
CPD-40251 (RA1425), 0786-CPD-40252 (RA1475)
UL Listing Category
Sprinklers, Automatic & Open (VNlV)
Quick Response Sprinkler
Product Description
Reliable Models F1 FR56, F1FR56LL, F1 FR42, F1FR42LL,
F1FRXLH & F1FR28 Series Sprinklers are quick response
sprinklers which combine the durability of a standard sprin-
kler with the attractive low profile of a decorative sprinkler.
The Models Fl FR56, Fl FR56LL, Fl FR42, Fl FR42LL,
XLH Upright XLH Pendent
F1FR42, F1FR42LL, F1FRXLH &
F1FR28 Series sprinklers to apply wa-
ter to a fire much faster than standard
sprinklers of the same temperature rat-
ing.
The glass bulb consists of an accu-
rately controlled amount of special fluid
hermetically sealed inside a precisely
manufactured glass capsule. This glass bulb is specially
constructed to provide fast thermal response.
At normal temperatures, the glass bulb contains the fluid
in both the liquid and vapor phases. The vapor phase can
be seen as a small bubble. As heat is applied, the liquid
expands, forcing the bubble smaller and smaller as the liq-
uid pressure increases. Continued heating forces the liquid
to push out against the bulb, causing the glass to shatter,
opening the waterway and allowing the deflector to distrib-
ute the discharging water.
Conventional
Recessed
Pendent/Fl/F2
*
Recessed
PendentjFP
XLH Recessed
Pendent F1/F2
4)
XLH Recessed
Pendent FP
S F1FRXLH & F1FR28 Series Recessed automatic sprinklers
utilize a 3.0 mm frangible glass bulb. These sprinklers have
demonstrated response times in laboratory tests which are
five to ten times faster than standard response sprinklers.
This quick response enables the Model F1 FR56, F1FR56LL,
Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Application
Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest
published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick
response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re-
sponse sprinklers should not be intermixed.
*p/n tie
(XLH Only)
Deflector
Load Screw
Washer Bulb
Frame Cup
0 14FGO6A
Model F1FR42, F1FRXLH Upright
Technical data:
Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure
F1FR56
**F1 FR56LL0 K 5.6
Quick 1/2" NPT See See F1FR42
**F1FR42LL0) K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table"
Fl FRXLH Ratings" Table.
F1FR28 K2.8
Low Lead Sprinklers available only with Temperature Rating 200°F/930C
Material Data:
Frame Deflector Load Screw *Pintle Cup Washer Bulb
DZR Brass CDA Alloy 260,
CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360
QM Brass or or or coated with PTFE Adhesive Glass
**Low Lead Brass or
CDAAlloy5lo CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape
S
2.
Model Fl FR56, Upright, Pendent & Conventional Sprinklers
Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
____________
Nominal K Factor
_______________
Sprinkler (SIN) __________
Approval
__________
Sprinkler Identification Number
Size US Metric Height Organization Upright Pendent
Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position
1/2" (15mm) (1) 1/2" NPT (131/2) 5.6 I 80 2.25' (57mm) 1.2,3,4,6 I
7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA142314 I RA14134
3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA1421'14 RA141 1
Conventional-Install in Upright or Pendent Position
15mm (1) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 1 RA14753
cULus listed corrosion resistant (Polyester coated) sprinkler.
Polyester coated FM approved sprinkler.
Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475.
Electroless Nickel PTFE (Teflon)* Plated - cULus listed Corrosion Resistant
Upright Pendent Conventional
Model Fl FR56LL & Fl FR42LL Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
____________
Nominal K Factor
________________
Sprinkler (SIN) __________
Approval
__________
Sprinkler Identification Number
Size US Metric Height Organization Pendent
Standard-Pendent Deflectors Marked to Indicate Position
1/2" (15mm) (1) 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1,5 RA1415
7/16(11mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1,5 RA1410
(1) cULus listed corrosion resistant (Polyester coated) sprinkler.
"DuPont Registered Trademark
91
4.
Vertical Sidewall
"DuPont Registered Trademark
Sprinkler Type Deflector to Ceiling Distance
(M n. - Max.)
Upright 4" (102mm) - 12" (305mm)
Pendent 4(102mm) - 12" (305mm)
Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(1)
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
K Factor Sprinkler
Height
Sprinkler Identification Number
(SIN) US Metric
1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414
7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1413
3/8" (10mm) I 1/2" NFl (R1/2) 2.8 40 2.25" (57mm) RA1411
(1) Refer to escutcheon data table for approvals & dimensions
Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler(1)
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
K Factor Sprinkler
Height
Sprinkler Identification Number
(SIN) US Metric
1/2" (15mm) 1/2" NPT(R1/2) 5.6 80 2.25" (57mm) RA1415
7/16" (10mm) 1 1/2" NPT (R1/2) 1 4.2 60 2.25" (57mm) RA1410
(1) Refer to escutcheon data table for approvals & dimensions
70 (700705
0 /0 07077700 ,_-I IURN COLLAR 7010 PLOt
FACE OF FIllING ID FACE OF CEILING 077007000 \\ I ' \ I flflCELtCW At77NE0LU7 RECESS ?T2704,,,ol AT WAIMUM RECESS JIBTIS~-]
CE -
AWOSIMOLT I II1EI IIWII L I III III till I I AT L700IMUM RECESS
I f l'I flJ (Ar WNIMW RECESS - fl I
At 70077GM RECESS - 1-118T2&6-1
-
AT 0/7077GM RECESS - I-5/0T41.3m,n1
IF
Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH &
F1FR28 Fl or F2
X I/PRODUCER
2 5/O' GM. [6& 7--1 -
HOLE IN COILING
2 5/I6 00.. [570
CUP
/
PA CE OF FIllING
PACE OP COILING OLMELODON
A MAXIMUM 7-I/2T38,mJ JAT r 00707077
I4I27oo,
AOIJLEL7MOII
AT MAXIMUM RECESS - 9/t6TI4JLOm] AT MINIMUM RECESS - IT25.lo,R,J
(82.6,RR
CA
,J 1
Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH &
F1FR28 FP
Model Fl FR56 Quick Response Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
Installation Data:
Nominal Nominal K Factor Sprinkler Approval Sprinkler
US Metric Orifice Thread Size Height Organizations Identification
Numbers (SIN)
½" (15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3 RA1485 23 15mm ½" NPT (R1/2) 5.6 80 2.25" (57mm) 3(1)
LPC Approval is for pendent position only.
cULus Listed corrosion resistant (Polyester coated) sprinkler.
Electroless Nickel FIFE (TeflonXI)* Plated - cULus listed corrosion Resistant
FACE OF FITTING TO FACE OF CEILING DIMENSION
Fl ESCUTCHEON
AT MAXIMUM RECESS = ("[25.4mm]
AT MINIMUM RECESS = 3/879.5mm]
F2 ESCUTCHEON
AT MAXIMUM RECESS = 3/4(19mm]
AT MINIMUM RECESS = 3/879.5mm]
2 1/4" HOLE OIA.
[5 7.2mm]
I" X 1/2" REDUCER
F? ESCUTCHEON
r002AT MAXIMUM RECESS 7-3/8[34.9mm] H 7 AT MINIMUM RECESS = 2-1/76752.4mm]
V F2 ESCUTCHEON
AT MAXIMUM RECESS = 1-5/8'r41.3mm1
AT MINIMUM RECESS 2-1/76752.4mm]
I [3.2mm]
Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler
Deflector: HSW
Installation Wrench: Model D Sprinkler Wrench
Installation Data: Horizontal Sidewall
Nominal K Factor Sprinkler Approval Organizations Sprinkler
_________________
Height and Type of Approval Nominal Orifice Thread Size Identification
US Metric Light Hazard Ordinary Numbers (SIN)Hazard
½" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1
cULus Listed corrosion resistant (Polyester coated) sprinkler.
Polyester coated FM approved sprinkler.
Electroless Nickel PTFE (TeflonB)* Plated - cULus listed Corrosion Resistant
Horizontal Sidewall
15/16" DIA.JjJ4
2 27/32" 0/A.
[72.2mm]
TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER I
WRENCH BOSS. Fl ESCUTCHEON
3/4(19mm] ADJUSTMENT
F2 ESCUTCHEON
1/2[12.7mm] ADJUSTMENT
I (1)
4-12"
[101.6mm-304.8mm]
CEILING TO
DEFLECTOR
RECESSED HSW W/F1 OR F2 ESCUTCHEON
(1) FM APPROVED FOR 4" - 6" [ID 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY.
Note: For Recessed HSW Sprinklers use installation wrench GFR2.
cULus permits use with Fl, F2 or FP escutcheons for "Light Hazard"
only. While FM limits use for the same hazard with the F2 escutcheon
only.
Model Fl FR56 Quick Response Concealed Pendent Sprinklers
Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
Nominal
Orifice
"K" Factor Thread
Size Model
Temp. Rating Max.
Ambient
Temp
Bulb
Color Approvals
Sprinkler
Identification
Number(SIN) US Metric Sprinkler Cover
½" (15mm) 5.6 80 ½" NPT F1 FR 135°F/570C 135°F/57°C 100°F/380C Orange 1 RA1414
½" (15mm) 5.6 80 1 ½" NPT I F1 FR 155°F/680C 1350F/570C 100°F/380C Red 1, 4(1), 6 RA1414
½" (15mm) 5.6 80 ½" NPT F1 FR 175°F/790C 165°F/740C 100°F/380C Yellow 1 RA1414
½" (15mm) 5.6 80 ½" NPT F1 FR 200°F/930C 165°F/740C 150°F/65°C Green 1 RA1414
(1) For VdS only = 1550F/680C Norbulb and 1/2" [12,7mm] adjustment.
Model Fl FR56LL Quick Response Concealed Pendent Sprinklers
Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
Nominal
Orifice
"K" Factor I I Thread
Size
I
Model I
Temp. Rating Max.
Ambient Bulb
Color Approvals
Sprinkler
Identification us I I Metric Sprinkler I Cover Temp Number(SIN)
½" (15mm) 5.6 80 ½" NPT F1FR56LL 200°F/93°C 1650F/740C 150°F/650C Green 1,5 RA1414
"DuPont Registered Trademark
5.
I" x 1/2" REDUCING
TEE OR ELBOW
S ET1 E
2 5/16" 0/A
CUP I
CEILING
VER USTM
COit3
5/I6" OJ
SPRINKLER
I" x 1/2" REDUCING
TEE OR ELBOW
—2 5/8' DIA.
HOLE IN CEILING
1 1/2" MAX.
FACE OF FITTING
_.._.._....TO FACE OF CEILING
DIMENSION
15/16"
2 5/16" 0/A -
CUP -_..
CEILING—A
5/16" MAX.
COVER ADJUSTMENT
COVER PLATE—
ASSEMBLY 5/16" 0/A.
SPRINKLER
- 2 5/8" DIA.
I-IDLE IN CEILING
I 1/2 MAX.
FACE OF FITTING
., TO FACE OF CEILING
DIMENSION
3/4"
CONCEALED, 1/2" ADJUSTMENT 07FGO CONCEALED, 5/16" ADJUSTMENT o,ni
S
S
Figure 1
Installation Aid
A protective cap is included for use during installation,
Important: The F1FR56 Sprinkler with Model OCR cover
plate is not an FM Approved combination,
Installation
Quick response sprinklers are intended for installation as
specified in NFPA 13. Quick response sprinklers and stan-
dard response sprinklers should not be intermixed,
The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH & F1FR28 Recessed Quick Response Sprin-
klers are to be installed as shown. The Model Fl or F2 Es-
cutcheons illustrated are the only recessed escutcheons
to be used with the Model F1FR56, F1FR56LL, F1FR42,
F1FR42LL, F1FRXLH & Fl FR28 Sprinklers. The use of any
other recessed escutcheon will void all approvals and ne-
gate all warranties.
When installing Model F1FR56, F1FR56LL, F1FR42,
F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model
D Sprinkler Wrench, Use the Model GFR2 Wrench for install-
ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH &
F1FR28 Recessed Pendent Sprinklers, Any other type of
wrench may damage these sprinklers.
NOTE: A leak tight ½" NPT (R112) sprinkler joint can be
obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do
not tighten sprinklers over maximum recommended torque.
It may cause leakage or impairment of the sprinklers.
The Models F1FR56/CCP & F1FR56LL/CCP Concealed
Sprinkler use the 1/2" orifice, 1/2 NPT (R112), Model F1FR56
& F1FR56LL Pendent Sprinkler with a threaded Model CCP
cup which is factory attached to the sprinklers. The Model
F1FR56 Pndent is available in temperature rating of 135°F
(57°C), 155°F (680C), 175°F (79°C) or 200°F (930C). The
Model F1FR56LL Pendent is available only in a rating of
200°F (930C). The concealed sprinkler assemblies are com-
pleted by the installation of the attractive low profile Model
CCP push on cover plate assembly, rated 135°F (57°C) or
165°F (74°C) for the Fl FR56 and 165°F (74°C) for the FIFR56
LL. The cover plate and sprinkler cup assemblies are joined
using a cover plate skirt with flexible tabs for threaded en-
*DuPont Registered Trade Mark
Figure 2
gagernent. A choice of two cover plate assemblies provide
either 1/2" (13mm) or 5/8" (8mm) of cover adjustment,
Do not install these sprinklers in ceiling which have positive
pressure in the space above.
After a 2/8" (67mm) diameter hole is cut in the ceiling, the
sprinkler is easily installed with the Model RC1 Wrench. A
Teflon* based thread sealant should be applied to the sprin-
kler threads only. The Model RC1 Wrench is then used to
engage the sprinkler wrenching surfaces and to install
the sprinkler in the fitting. When inserting or removing the
wrench from the sprinkler/cup assembly, care should be tak-
en to prevent damage to the sprinkler. DO NOT WRENCH
ON ANY OTHER PART OF THE SPRINKLER. The cover
plate is then pushed onto the cup. Final adjustment is made
by hand turning the cover plate until the skirt flange makes
full contact with the ceiling. Cover plate removal requires
turning in the counter clockwise direction.
After installation, inspect all sprinklers to ensure that there
is a gap between the cover plate and ceiling and that the
four cup slots are open and free from any air flow impedi-
ment to the space above.
Concealed cover plate/cup assemblies are listed only for
use with specific sprinklers. The use of any other concealed
cover plate/cup assembly with the Model F1FR56 Pendent
Sprinkler or the use of the Model CCP Concealed cover
plate assembly on any sprinkler with which it is not specifi-
cally listed my prevent good fire protection and will void all
guarantees, warranties, listings and approvals.
Glass bulb sprinklers have orange bulb protectors to
minimize bulb damage during shipping, handling and in-
stallation. REMOVE THIS PROTECTION AT THE TIME THE
SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE
PROTECTION. Removal of the protectors before this time
may leave the bulb vulnerable to damage. RASCO wrench-
es are designed to install sprinklers when covers are in
place. REMOVE PROTECTORS BY UNDOING THE CLASP
BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO-
TECTORS.
C
Temperature Ratings
Classification
Sprinkler
Temperature Max. Ambient
Temp. Bulb Color 0c
Ordinary 57 135 100°F (38°C) Orange
Ordinary 68 155 100°F (38°C) Red
Intermediate 79 175 150°F (66°C) Yellow
Intermediate 93 200 150°F (66°C) Green
High " 141 286 225°F (107°C) Blue
(1) Not available for recessed sprinklers.
Escutcheon Data (1)
(1) SIN RA1435 - cULus perms use with Fl F2 or F escutcheons for light
hazard" only, while FM limits use for same hazard with F2 escutcheon only
Maintenance
The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH and Model F1FR56, F1FR56LL, F1FR42,
F1FR42LL, F1FRXLH & F1FR28 Recessed Sprinklers should
be inspected and the sprinkler system maintained in accor-
dance with NFPA 25. Do not clean sprinklers with soap and
water, ammonia or any other cleaning fluids. Remove dust
by using a soft brush or gentle vacuuming. Remove any
sprinkler which has been painted (other than factory ap-
plied) or damaged in any way. A stock of spare sprinklers
should be maintained to allow quick replacement of dam-
aged or operated sprinklers. Prior to installation, sprinklers
should be maintained in the original cartons and packaging
to minimize the potential for damage to sprinklers that would
cause improper operation or non-operation.
Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Recessed Pendent
Vertical Sidewall
Horizontal Sidewall
Recessed Horizontal sidewall
Concealed pendent
Maximum Working Pressure
175 psi (12 bar)
100% Factory tested hydrostatically to 500 psi (34.5 bar)
Finishes (1)
Standard Finishes
Sprinkler Escutcheon Cover plate'
Bronze Brass Chrome
Chrome Plated Chrome White
Polyester Plated
Coated (4)(5)(6) 1 White Painted
Special Application Finishes
Sprinkler Escutcheon Cover plate 1)
Electroless Nickel
PTFE(TefIon )*(7)
Electroless Nickel
PTFE (Teflon®)* Bright Brass
Bright Brass (3) Bright Brass Black Plating
Black Plated Black Plated Black Paint
Black Paint26 Black Paint Off White
Off White (2)(6) Off White Satin Chrome
Chrome Dull Chrome Dull
Other finishes and colors are available on special order. Consult the
factory for details. Custom color painted sprinklers may not retain their
UL Corrosion resistance listing. Coverplate custom paint is semi-gloss,
unless specified otherwise.
cULus Listed only.
200°F (93°C) maximum.
cULus listed "corrosion resistance" applies to SIN Numbers RA1435
(HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and
RA1415 (Pendent) in standard black or white. Corrosion resistance in
other polyester colors is available upon request.
FM Approvals finish as "Polyester coated" applies to SIN Number
RA1414, RA1435 and RA1425 in standard black or white.
LPCB and VdS Approved finish appliesonlyto RA1425, RA1414 and RA1475.
cULus listed Corrosion Resistant
Ordering Information
Specify:
Sprinkler Model
Sprinkler Type
Orifice Size
Deflector Type
Temperature Rating
Sprinkler Finish
Escutcheon Type
Escutcheon Finish (where applicable)
Cover plate Model
Cover plate Thread size
Cover plate Temperature
Cover plate Adjustment
Cover plate Finish
Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers
and escutcheons are packaged separately.
*DuPont Registered Trademark
7.
Model G5-80, Model G5-56, 0
Model G5-42, Model G5-28 C
Quick Response Concealed
Automatic Sprinkler LU
Plain Cover Plate
Bulletin 034 Rev. D
ReI m ®R iabui
UL Quick Response
FM Standard Response
Concealed Sprinkler With a
3/4 (19mm) Adjustment
Features
Cover plate attachment (Plain or Perforated) with
3/4" (19mm) assembly adjustment.
Smooth aesthetic ceiling profile.
Factory installed protective cap.
Available in Chrome and White as Standard Finish-
S
S
es. Special Application Finishes are also available.
5. Ordinary and Intermediate temperature rating.
For additional Sprinklers refer to Bulletin 154 for
Technical Specification and Approvals
Approvals & Listings
1. Underwriters Laboratories Inc. and cULus -
Quick Response
G5-80, G5-56 - Light Hazard and Ordinary
Hazard Occupancies
G5-42 - Light Hazard Occupancies
G5-28 - Light Hazard Occupancies
2, Factory Mutual Research Corp. (FM) -
Standard Response (See Page 3)
G5-56 & G5-28 only.
See the most recent FM Global Property
Loss Prevention Data Sheets for installation
and use guidelines.
Loss Prevention Council (LPCB, UK) -
Standard Response
G5-56 - Light Hazard and Ordinary Hazard
Occupancies
VdS Schadenverhutung GmbH -
Standard Response
EC-Certificate of Conformity 0832-CPD-2062
U.S. Patent number 6,554,077.
Application
The Reliable Model G5-80, G5-56, G5-42 and G5-28 are
the most versatile quick response concealed sprinklers avail-
able. It provides the best form of fire protection while offering
an attractive appearance and 3/4" (19mm) of cover adjust-
ment for ease of installation. The small diameter cover plate
assembly is easily attached and blends into the ceiling, con-
cealing the most dependable fire protection available, an au-
tomatic sprinkler system.
,
-------------
------------------
/1
Perforated Cover Plate
The Model G5-80, G5-56, G5-42 and G5-28 are designed
for use where aesthetic appearance is important. Offices, hos-
pitals, motels and restaurants are but a few of the applications
where it can be used.
The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed
Quick Response Concealed sprinklers intended for use in
accordance with NFPA 13, FM Approves the G5-56 and the
G5-28 sprinkler as a standard response concealed sprinkler
intended for use in accordance with FM Loss Prevention Data
Sheet 2.0.
Product Description
The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses
a proven quick response fusible element in a standard style
sprinkler frame with a drop-down deflector. This assembly is
recessed into the ceiling and concealed by a flat cover plate
assembly. The threaded engagement provides 3/4" (19mm) of
cover adjustment. The flat cover plate is attached to the skirt
using either 135°F (57°C) or 165°F (74°C) ordinary tempera-
ture classification solder.
When the ceiling temperature rises, the solder holding the
flat cover plate melts, the flat cover plate released thus expos-
ing the sprinkler inside to the rising ambient temperature.
The subsequent fusing of the element opens the waterway
and causes the deflector to distribute the water. Any secure
engagement between the cover plate and cup will assure that
the drop-down deflector is properly located below the ceiling.
Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model FC Sprinkler Wrench
UL Listing Category
Sprinklers, Automatic and
Open
Quick Response Sprinkler
UL Guide Number
VN IV
Installation
Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings
•
which have positive pressure in the space above.
Cut a 2 /8" inch (67mm) diameter hole is cut in the ceiling, the
sprinkler is easily installed with the Model FC Wrench. The
wrench has a socket drive which is inserted into the body of
the sprinkler. When installing a sprinkler the wrench is first
positioned into the sprinkler/cup assembly until the wrench
socket engages the body of the sprinkler. The sprinkler is
then tightened into the pipe fitting. When inserting or remov-
ing the wrench from the sprinkler/cup assembly, care should
be taken to prevent damage to the sprinkler. DO NOT
WRENCH ON ANY OTHER PART OF THE SPRINKLER!
CUP ASSEMBLY. Install the cover plate by hand turning the
cover in the clockwise direction until it is tight against the ceil-
ing.
A protective cap is provided to protect the drop-down sprinkler
deflector from damage which could occur during construction
before the cover plate is installed. The cap is factory installed
inside the sprinkler cup. Remove cap to install sprinkler, then re-
install cap until the cover plate is installed.
Maintenance
The Model G5-80, G5-56, G5-42 and G5-28 should be in-
spected and the sprinkler system maintained in accordance
with NFPA 25. Do not clean sprinklers with soap and water, am-
monia or any other cleaning fluids. Remove any sprinkler that
has been painted (other than factory applied) or damaged in
•
any way. Concealed sprinklers cover plates can not be painted
in the field, after installation or have any other coating applied
other than the factory finish. A stock of spare sprinklers should
be maintained to allow quick replacement of damaged or oper-
ated sprinklers. Prior to installation, sprinklers should be main-
tained in the original cartons and packaging to minimize the
potential for damage to sprinklers that would cause improper
operation or non-operation.
Ordering Information
Sprinkler Model
Nominal Orifice
Flat Cover Plate
Plain or Perforated
Flat Cover Plate
Assembly Finish
Inlet Type
Cover Plate Finishes(')
Standard Finishes
Chrome
White Paint
Special Application
Finishest2
Bright Brass
Finished Bronze
Black Plating
Black Paint
Off White
Satin Chrome
Other finishes and colors are
available on special order.
Consult factory for details.
Coverplate custom paint is
semi-gloss, unless specified
otherwise.
For the perforated style cover-
plate, consult factory for avail-
ability on these and other cus-
tom finishes.
Maximum Working Pressure
175 psi (12 bar)
100% Factory tested Hydrostatically to 500 psi (34.5 bar)
Temperature Rating
I I Cover I I Max. Ambient Classification Sprinkler
I Temp.
Ordinary 1651F/741C 1351F/57°C i 100°F/380C
Intermediate I 212°F/100°C I 165°F/74°C 150°F/66°C
2.
C
Technical Data
Sprinkler
Model Sprinkler Inlet Total
Adjustment
Nominal
Orifice
Nominal
K Factor ______ Thread Approvals Sprinkler
Identification (SIN) US Metric
G5-80 Non Adjustable 3%"(19mm) 17/32"(l5mm) 8,0 115 3%" NPT(R3,4) 1 RA3412
G5-56 Non Adjustable 1 34"(19mm) 1 1/2"(l5mm) 1 5.6 80 ½" NPT(R½) 1,2,3,4,5 1 RA3415
G5-42 Non Adjustable 3,4"(l9mm) 7/16"(lOmm) 4,2 60 1/2" NPT(R½) 1 RA3413
G5-28 Non Adjustable 34" (19mm) /" (10mm) 2,8 40 1/2 NFl (R½) 1,2 RA341 1
For VdS Approval, temperature rating sprinkler 1650F174°c and cover plate 1350F/570C only!
x 7/2" REDUCING
TEE OR ELBOW I 1" 3/4" REDUCING TEE OR ELBOW
G58O ONLY
2k" [58.42mm] 0/A
CUP
" [19.05mm] MAX.
COVER ADJUSTMENT
1/4 [6.35 MIN TO CEILING J
1" [25.4mm] MAX. if DROPPED DEFLECTOR
TO CEILING
8 L""J
HOLE IN CEILING
7
2-1/4" [57. 15mm] MAX.
FACE OF FITTING
TO FACE OF CEILING
DIMENSION
" [4.96mm]
FLAT COVER PLATE
ASSEMBLY " [84.21mm] D/A.
LI
C
SPRINKLER
COVER PLA TE: 3/4" [19. 05mm] ADJUSTMENT
Notice
FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS
x 7/2W REDUCING
TEE OR ELBOW
-Iii---
- I
RELIABLE P/N 6999997900 71 I
xj BRASS NIPPLE EX7-.
2e [58.42mm] 0L4
CUP
J. (79.05mm) M4X
COVER ADJUS7MENT I
1/4 (6.JSm MIN. CEILING J
1 [25.4mm) MAX.
DROPPED DEFLECTOR
To CEILING
2k" (66.55mm) I HOLE IN CEILING
3-1/76 [77.72mm) MAX,
FACE OF FiniNG
IV FACE OF CEILING
DIMENSION
2-1/4[57.15mm] MAX.
FACE OF NIPPLE EXT. 70 FACE OF CEILING
DIMENSION
/" (4.96mm)
(84.2 1mm) DL4.
FLAT COVER PLATE -1
ASSEMBLY SPRINKLER
aRFMM COVER PLATE: 3/4" [19.05mm] ADJUSTMENT
Testing has shown that use of a "nipple extension" will not affect the listing of the sprinkler.
For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe
thread size as the existing outlet when revamping existing systems".
Do not exceed 8-18 ft-lbs of torque during installation.
3.
Reliable...For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Automatic sprinklers
Flush automatic sprinklers
Recessed automatic sprinklers
Concealed automatic sprinklers
Adjustable automatic sprinklers
Dry automatic sprinklers
Intermediate level sprinklers
Open sprinklers
Spray nozzles
Alarm valves
Retarding chambers
Dry pipe valves
Accelerators for dry pipe valves
Mechanical sprinkler alarms
Electrical sprinkler alarm switches
Water flow detectors
Deluge valves
Detector check valves
Check valves
Electrical system
Sprinkler emergency cabinets
Sprinkler wrenches
Sprinkler escutcheons and guards
Inspectors test connections
Sight drains
Ball drips and drum drips
Control valve seals
Air maintenance devices
Air compressors
Pressure gauges
Identification signs
Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly
S qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
Reliable Automatic Sprinkler Co., Inc.
9
Recycled
® (800) 431-1588 Sales Offices Paper Reliabi (914) 829-2042 Corporate Offices C (800) 848-6051 Sales Fax Revision lines indicate updated or new data.
www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11/14 P/N 9999970421
RING HANGER
I thru 4 inch pipe 112 and 3/4 inch pipe
5 thru 8 inch pipe
SIZE - 1/2 thru 8 inch pipe.
MATERIAL - Carbon Steel, Mu. Galvanized to G-90 specification.
FINISH - Mu. Galvanized and Stainless Steel.
LISTING - UL in US and CANADA.
APPROVAL - Factory Mutual Research.
CONFORMS WITH: Federal Specification WW-H-171 (Type 10),
Manufacturers Standardization Society ANSIfMSS-SP-58 (Type 10); install
in accordance with ANSI/MSS- SP-69.
MAXIMUM TEMPERATURE - 6500F.
FUNCTION - For fire sprinkler and general piping purposes.
Swivel nut permits hanger adjustment after installation.
FEATURES -
lthru4 inch:
* Offset edge for EASY pipe insertion.
1 thru 8 inch:
* Full length knurl on swivel nut for better grip.
UNIQUE FEATURES
1 thru3 inch:
* UL listed to accept AFCON #310 Surge Restrainer.
* Swivel nut
Retained in ring to keep the assembly intact prior to installation.
Removed easily if needed.
* UL listed for use on CPVC pipe.
ORDERING - Part # and pipe size.
Index
IMPERIAL MAX REC.
LOAD LBS.
METRIC*
PIPE ROD PIPE ROD
1/2 3/8 400 10
400 20 10
1 318 400 25 10
1 114 3/8 400 32 10
3/8 400 0 10
2 3/8 400 50 10
21/2 3/8 600 65 10
3/8 600 80 10
3112 600 10
4 1000 100 __
S 1250 125 12
6 1250 12
8 2 1250
1501
200
* Order Part #300m
Note: 1/2' Ring Hanger not <FM> approved
F~
S
655
ALL THREADED ROD CUT TO LENGTH
ROD
SIZE
MAX. REC. LOAD LBS.
FOR SERVICE TEMP.
650°F 750°F
3/8 610 540
1/2 1130 1010
5/8 1810 1610
3/4 2710 2420
7/8 3770 3360
NOTE; maximum Temperature: 750°F
SIZE - 3/8 thru 7/8 inch rod in 1 inch
increments.
MATERIAL - Carbon Steel.
FINISH - Plain, Electro-Galvanized and
Stainless Steel.
ORDERING - Part #, rod diameter, rod
length and finish.
2/00
E5
Will] IIT (Veilical iTflTi
Use #14 Nut Driver (Item #100)
Item # Model Shk Lgth Shk Dia Box Qty Weight Case (per 100) Qty
20 GST.750 3/4 1/4 100 4.75 1000
21 CST 100 1 1/4 100 5.00 1000
22 CST 200 2 1/4 100 6.50 1000
23 GST300 1 3 1/4 100 1 7.50 1000
24 IGST600 1 6 1 1/4 1 50 1 9.00 500
S
WOOD - Sammys
i
#14
(Item #100-black)
Sammys 1/4', 3/8" rod
WOOD - 3/8" Rod &'7TI?1L.I lT1T1Th
Use #14 Nut Driver (Item #100)
Approvals Item # Model Shk Lgth Shk Dia FMTest
Load, lb.
ULlest
Load lb. UL/FMActual Pipe Size
Pullout Box Qty
10 GST.75 3/4 1/4 564#-6Ply 100
NFPA 11 GST10 1 1/4 210# - 7/16 OSB 100 6704 - 3/4" Ply
IUL.FMNlPA 12 CST 20 2 1/4 9404 850# 3/4-2 1/2 17604-Fir 100
UL-NFPA * 27 CST 25-380 21/2 3/8 15004 4 21134-Fir 50
UL-FM-NFPA 13 CST30 3 1/4 14754 1500# 3/4-4 20604 -Fir 100
NFPA 403 GST40 4 1/4 2180# - Fir 50
NFPA 1 14 IGST60 1 6 1 1/4 1 1 2230# - Fir 50
#I4SW
(Item #101-red)
Sidewinders &
Sammys 1/2" rod
WlIl] riiRod(Veifical
Use #14SW Nut Driver (Item #101)
Item # Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight
(per 100) Case Qty
8 CST 2 2 1/4 1760# - Fir 50 7.00 500
* 06 CST 2.5-380 21/2 3/8 21134-Fir 50 10.00 500
15 IGST3 1 3 1 1/4 1 2275# - Fir 1 50 10.50 500
16 JGST4 1 4 1 1/4 1 2180#-Fir 1 50 1 10.60 1 500
17 ICST6 1 6 1 1/4 1 22304- Fir 1 50 1 10.95 1 500
Not less than
2" nominal width
(11/2")
TJI Joist/ Truss
Consult truss manufacturer for
recommended installation point.
*pre_drilling may be required :3
for items #27 and #06.
Tools available on page 9.
03 5-
q Wood Joist
S (
Double Sheetrock Ceiling Minimum 2" imbedment into base
material for NFPA 13 compliance
For vertical use.
Install in center
oflowerface. per NFPA1
L 26
Page 4 Note: Screws must be installed with appropriate nut driver to comply with warranty
WOOD —Sidewinders
IWlIS] VLIRodrum mIk11ITrrITh
'Use #I4SW Nut Driver (Item #101)
Item# Model ShkLgth ShkDia I Actual I I Shear/Pullout
I Box Qty Weight
(per 100) ICase Qty
4016 SWG 100 1 1/4 I 100 7.50 I 1000
300 SWC 200 2 1/4 17254 - Fir 100 8.00 1000
IWlIS] IYItIITrI(11mizonta ll1 ITITITi
Use #14SW Nut Driver (Item #101)
Approvals Item# Model Shk Lgth Shk Dia IL Test
Load lb.
UIIFM
Pipe Size
ActualBox Shear/Pullout Qty Weight
(per 100)
18 SWG 10 1 1/4 100 6.00
UL•NFPA 19 SWG2O 2 1/4 1250# 3 1725# -Fir 100 7.00
UL•NFPA * 26 SWG25-380 21/2 3/8 15004 4 2249# -Fir 50 10.25 -
25 ISWC,30 1 3 1 1/4 1 1 1 50 1 8.50
S
#I4SW
(Item #101-red)
Sidewinders &
Sammys 1/2" rod
o. Prestressed Concrete
C2 -j
Page 5
Not less than 2" nominal width (11/2") up
to 31/2" pipe; not less than 3" nominal
width 4 & 5" pipe
FloorJoist r '
TJI Joist! Truss
Consult truss manufacturer for
recommended installation point.
*pre_drilling may be required
for item #26.
Tools available on page 9.
II3 Minimum 2 112" from bottom for
branch lines. Minimum 3" from
bottom for main lines. Exception:
I
This requirement shall not apply to
2" or thicker nailing strips resting
SHEETROCK -Toggle
on top of steel beams.
:1 i (II r(Verticalu miii
Use #14 Nut Driver (Item #100)
Item # Model Shk Lgth Shk Dia Actual Pullout Box Q, Weight Case Qty (per 100)
71 SST 300 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock
#14
(Item #100-black)
Sammys 1/4", 3/8" rod
C
I1fl D I tII r1k (VerticalMount)
Use #14 Nut Driver (Item #100)
Item# Model Shk Lgth1 Shk Dia Actual Pullout Pkg Qty Weight Case Qty (per 100)
70 ISST 30 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock
Note: Screws must be installed with appropriate nut driver to comply with warranty