Loading...
HomeMy WebLinkAbout5823 NEWTON DR; ; FPC2018-0346; PermitPERMIT REPORT (r,city of Carlsbad Print Date: 12/16/2021 Job Address: 5823 NEWTON DR, CARLSBAD, CA 92008-7361 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: THERMO FISHER SCIENTIFIC - FIRE ALARM TI ADD ADDRESSABLE DUCT TYPE SMOKE DETECTORS T NEW A/C UNITS ON 2ND FL ADD FIRE LARM STROBES AT NEW CONFERENCE ROOM ON 151 FL RELOCATE WALL OUNT FIRE ALARM HORN/STROBE TO OPEN OFFICE AREA Permit No: FPC2018-0346 Status: Closed - Finaled Applied: 10/18/2018 Issued: 11/02/2018 Finaled Close Out: 02/04/2021 Inspector: Final Inspection: Applicant: FPContractor: JMG SECURITY SYSTEMS JMG SECURITY SYSTEMS JUSTIN WALD 17150 NEWHOPE ST, #109 17150 NEWHOPE ST, # STE 109 FOUNTAIN VALLEY, CA 92708-4273 FOUNTAIN VALLEY, CA 92708-4250 (714) 545-8862 (714) 545-8882 x326 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov HIGHLIGHTED SET UL & FM Certificates of Compliance Cut Sheets and CSFM listings Thermo Fisher. S C I E N T I F I C Tenant Improvements 5823 Newton Drive, Carlsbad, CA 92008 Installation Company: ,j MG SECURITY SYSTEMS Our service is your security. 17150 Newhope Street Fountain Valley, CA 92708 (714) 545-8882 FPC20 18-0346 5823 Newton DR THERMO FISHER SCIENTIFIC FIRE ALARM TI ADD ADDRESSABLE DUCT TYPE SMOKE DETECTORS T NEW A/C UNITS ON 2ND FL ADD FIRE LARM STROBES AT NEW CONFERENCE 10/18/2018 FPC20I8..0346 1 Applicant ID No: 257057-001 Service Center No: I Expires: 31-MAR-2019 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Comoanv indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: LAKE FOREST, CA Alarm Service ComDanv: (257057-001 ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 Service Center: (257057-001 ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category, - BP103071 CRZM' Monitoring Stations, National Industrial Security S81261 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station / ***THIS CERTIFICATE EXPIRES ON 31MAR2O19*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" UL LLC CERTIFICATE OF COMPLIANCE COVER PAGE Applicant Subscriber No: 257057-001 Service Center Number: 1 Service Contract No: - ACTIVE LISTINGS CCN File No. Vol. No. UUFX S8126 1 CRZM BP10307 1 Listed Service From: LAKE FOREST, CA Alarm Service Company: ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 Service Center: ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 01-APR-15 Tr SILENT (lntemKnight® Model 582OXL J KNIGHT iAddressable Fire5 by Honeywell C"rm Control System) The lntelliKnight System is the easy way to make the most of fire alarm technology. lntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. Uses standard wire—no shielded or twisted pair required Built-in digital communicator Central station reporting by point or by zone Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® FlexputTM I/O circuits Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Built-in annunciator with 80-character LCD display RS-485 bus provides communication to system accessories Built-in RS-232 and USB interface for programming via PC Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Improvements in SKSS software deliver five times faster uploads/downloads Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Model 5820XL 6 amp power supply and maximum charging capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) Programmable date setting for Daylight Saving Time Installation The 5820XL can be surface or flush mounted Compatibility The 5820XL signal line circuit (SLC) supports multiple device types of the same protocol: SK (System Sensor) SD You cannot mix SD and SK SLC devices on a FACP. lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal System Application 5820XL has one built-in signalling line circuit (SLC) which supports multiple devices dependent on protocol being used. Three additional loops can be added using the 5815XL SLC expanders to increase overall capacity. The 5820XL SLC loops support multiple device types, including: Addressable photoelectric smoke detector Addressable ionization smoke detector Addressable heat sensor Addressable duct smoke detector Contact module Relay output module Addressable notification module Addressable beam detector (SK protocol only) Addressable multi-criteria smoke detector (SK protocol only) Addressable multi modules (SK protocol only) The following advanced sensor capabilities are available with 5820XL: Automatic drift compensation Maintenance alert Built-in sensor test to comply with NFPA 72 calibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours. An additional cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. Flexput circuits on 5820XL control can be inthvidually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4-wire smoke detectors. The 5820XL system operates on non- twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51 specifications for power-limited fire protective signalling cables. No special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the lntelliKnight system features a built-in walk test and auto- programming. Its innovative, dead-front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. Programming The lntelliKnight system offers several options to simplify and speed up programming. The JumpStart® feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windows®- based software. Built-In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch-Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel InteIIiKnight 5820XL Facility Addressable Fire Alarm System Uanagsnt$oftwars SK (System Sensor) Protocol Devices WrtdowsBas.d WlDewnlesd Sotwur, UJI -, R3232 4 Receiver Ia\ A A — Socr. - T SK-22uD Connection VisorAlarm IP Communicator Fn-mCRetuevs 3 ruedm C 86950. treetiunul AoueteModule Q EI—*pl 5860 Remote Annunontor 5824 PrrutorfGOoueoi MOAUA (21ke Medt&/Ouen 6 Ftwicpu*' 80 Circuits CWt bti 01Outputs enI3.3to,.oa-n,. eudriOcru ptjlsraumd A 5$ rued soon tttfl Inrrnti Dctectm 8K4n0 IKCculml4 .COrdntt 8200SJ A.AcC14me SK-Zom LA Iruittw Ad&emeRAe sxoruesoj Sowider Mutinteurue Sore Module trorrceton t,oI Bon wructre IrCodwir moorie PutodUte detectOC M03J0 $K48en SK8tn.10 $l(4en.T M1oono MQccrued Ikeitro BennOetenxor module $Ic.a1non4 Qc4Accd Dfl4R5 8Z24I I26cI.P AdJrCOUIue Stc4IeROR RUtnj snore tuwiror AuUtMonAr (44InI44T Don SQ/Two 00w/n Aoredneteo In SK-Re IKZone *(ReMy Reety Co/Tot AdSue0000lo MJtontlo Module lnteutnce Rtewy Muddle Muddle ., I Use 6is5880tocontro1upto4 I 5 883 $865-4 or 5*65.3 LED A/Tiendetx (mOod rC0550) lntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.5A or 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power-limited Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power-limited Auxiliary power circuits: 3A @ 27.4VDC per circuit, power-limited Initiation Circuits: 100 mA@ 27.4VDC per circuit, power limited Physical Flush Mount Dimensions: 14.5W x 24.75"H x 3.9"D (36.8 W x 62.9 H x 9.8 D cm) Overall Dimensions: 16.2"W x 26.4"H x4.2"D (40.6W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red ry Charging Capacity: 7.0-35 AH) Battery Size: 18 AH max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) S-BUS Accessories 5860111 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 5860R is red. 5815XL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the lntelliKnight system. 5820XL supports three 5815XL's. Each 5815XL can support 99 SK detectors and 99 SK modules or 127 SD devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6 Flexput I/O circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides four power-limited notifi- cation appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs, and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Suite (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SD505-DTS-K Remote test switch. Used with 5D505-DUCTR. Provides remote key operated test function and annunciation of detector alarm. SD and SK Devices See the specification sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices Data Sheet 53623 SK Devices Data Sheet D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 by Honeywell Phone: (203)464-7161, Fax: (203)484-7118. www.siIentknight.com lntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight Made in America PN 350210 Rev H2 © 2012 Honeywell International Inc. Model 5820XL / 5820XL-EVS Installation Manual LS1006I-00ISK-E 3.5 Board Assembly Diagram On-board Annunciator To AC tssis inting S V Switch ut rog ramming orts Figure 3-2 shows the circuit boards, metal housing and annunciator that attach the 5820XL I 5820XL-EVS assembly to the cabinet. If you should need to remove the board assembly for repair, remove the four mounting nuts which hold the assembly in the cabinet. Then lift the entire assembly out of the cabinet. Do not attempt to remove the circuit boards from the metal bracket. 3-5 Control Panel Installation LS10061-001SK-E Figure 4-8 SBUS Class B Wiring 4.5 5860 Remote Annunciator Installation The optional Model 5860 Remote Annunciator, shown in Figure 4-9, performs the same functions as the on- board annunciator. It can initiate and end fire drills with a single key press and view event history by alarms, supervisories, or troubles. Up to 12 annunciators can be added to the IntelliKnight 5820XL I 5820XL-EVS system. Note: The EVS-RCU contains a 5860 and counts toward one of the eight annunciators. FIRE ALARM ANNUNCIATOR 1::= SELENT 0 IM IR SLNC Im Figure 4-9 Model 5860 Remote Annunciator, Front View 4-8 LS1006I-001SK-E Before You Begin Installation 3.6.3 Current Draw Worksheet for SD SLC Devices Use to determine current requirements during alarm/battery standby operation when SD SLC devices are installed. You can install up SD devices per loop (Max per panel). Copy this section if additional space is required. Table 3-3: Current Draw Worksheet for SD SLC Devices Device # of Devices Current per Device Standby Current Alarm Current i-or each device use this tormula: I hit, column X this column = Current per number ot devices. lntelliKnight 5820XL Fire Panel (Current draw from battery) 1 Standby: 275 mA 275 mA Alarm: 440 mA 440 mA [ Addressable SLC Devices SD500-AIM (508 max.)1 Standby/Alarm: .55 mA5 mA mA SD500-MIM mA mA SD500-PS mA mA SD500-ARM mA mA S0505-AHS mA mA 50505-AIS mA mA S0505-APS mA mA SD500-ANM (508 max.)' Aux. Pwr Standby: 8 mA mA Alarm: 60 mA mA SLC Standby/Alarm: .55 mA mA mA SD500-SDM (508 max.)' SLC Standby/Alarm: .55 mA mA Aux. Pwr Standby: 20 mA mA Alarm: 106 mA mA SDSOO-LED (100 max.)' Aux. Pwr Standby: 10 mA mA Alarm: 220 mA mA LED: lOmA mA mA SLC Standby/Alarm: .55 mA mA mA SLC Accessory Bases SD505-6RB (508 max.) Standby/Alram: .082 mA mA mA SD505-6SB (508 max.) Aux. Pwr Standby: 1 mA mA Alarm: 32 mA mA rnP mA mA 'SD505-DUCTRJ ______ ((508 max. rJ andby) ÔmA2, 'Alarm:) 62 mA _________ ________ mA SLC Standby/Alarm: .5 mA I mA mA D5ô5-DTS-Kj ((508 max)) None, included with 50505-OUCTR worst case) SD505-DUCT (508 max.) None, included with detector current. SLC Isolator Devices SD500-LIM (1024 max.) Standby/Alarm .092 mA (508 max.) mA mA SD505-61B Accessories Modules 5815XL SLC Expander (3 max.) Standby/Alarm: 55 mA mA mA 5860 Remote Fire Alarm Annunciator. *EVSRCU contains one 5860 and must be added to the calculation here.'. (12 max.) Standby: 20 mA mA Alarm: 25 mA mA 5824 Serial/Parallel Printer Interface (2 max.) Standby/Alarm: 45 mA mA mA 5895XL IntelliKnight Power Expander (8 max) Standby/Alarm: 10 mA mA mA 5496 Intelligent Power Module Standby/Alarm: 10 mA mA mA 5865-4 LED Annunciator (with reset and silence switches) (8 max.) Standby: 35 mA mA Alarm: 145 mA mA 5865-3 LED Annunciator Standby: 35 mA mA Alarm: 145 mA mA 5880 LED I/O Module Standby: 35 mA mA Alarm: 200 mA mA 3-10 A C D E F C H Model 5820XL / 5820XL-EVS Installation Manual LSI006I-00ISK-E Table 3-3: Current Draw Worksheet for SD SLC Devices Device # of Devices Current per Device Standby Alarm Current Current 5883 lelay Interface (32 max.) Standby: U mA mA Alarm: 220 mA (22 mA per relay) mA EVS-VCM Voice Control Module (1 max.) Standby: 70 mA mA Alarm: 100 mA mA EVS-SW24 Switch Expander (5 max.) Standby: 10 mA mA Alarm: 25 mA mA EVS-50Wor EVS-125WAudio Amplifier with/without EVS-CE4 (4 max.) Standby: 10 mA mA Alarm: 10 mA mA EVS-RVM Remote Voice Module * The EVS-RCU contains one EVS-RVM and must be added to the calculation here 4 max Standby: 70 mA mA Alarm: 100 mA mA EVS-100W lOOWAmplifier (4 max.) Standby/Alarm: 10 mA mA mA EVS-100WBU backup daughter card (4 max.) Standby/Alarm: 10 mA mA mA Total System Current Auxiliary Devices3 Refer to devices manual for current rating. Alarm/Standby: mA mA Alarm/Standby: mA mA Alarm/Standby: mA aA mA Alarm/Standby: mA mA Auxiliary Devices Current Alarm: mA mA Alarm: mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Total current ratings of all devices in system (line A + line B + C) mA mA Total current ratings converted to amperes (line D x.001): A A Number of standby hours: H Multiply lines E and F. Total standby AH AH Alarm sounding period in hours. (For example, 5 minutes = .0833 hours) H Multiply lines E and H. Total alarm AH AH Add lines G and 1.4 Total ampere hours required AH Total does not include isolator devices or accessory bases. If using 24 VDC aux power only. No standby or alarm current for battery calculation if using 24 VAC, 120 VAC 01240 VAC. If using door holders, you do not need to consider door holder current for alarm/battery standby, because power is removed during that time. However, during normal operation, door holders draw current and must be included in the 6-OA total current that can be drawn from the panel. Use next size battery with capacity greater than required. The FACP can only support 2 devices wILED's on. This current draw has been added to the panels alarm current. 3-11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 1165-0559:0135D Page 1 of 2 CATEGORY: (7165-- FIRE ALARM CONTROL UNITJ(COMMERCIAL) LISTEE: (SILENT KNIGHT SECURlTYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.kireyev@honeywell.com DESIGN: Models 5820,20XL) IFP-1000 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterflow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5820, 5820XL, IFP-1000: Control Units 058200P: Motherboard 5815/5815XL: Analog Loop Expander 7628: EOL Resistor Intelliknight 5820: Enclosure 5860/5860R1RA-1000: Annunciator 5496: Power Module 5824: Serial/Parallel Interface 5895/5895XL/RPS-1000: Power Expander/Supply 5865-3/5965-4: LED Annunciator 5880: LED 10 Module 5883: Relay Interface Board SD500-ANM : Addressable Notification Module SDSOO-LIM: Line Isolation Module 5D505-61B: Isolation Base SD-500 SDM: Smoke Detector Module RA-100: Remote Annunciator 3158: Reverse Polarity Module 5220: Direct Connect Module 122365: Enclosure *RBB : Battery Cabinet 5897, 5898: Power Supplies 058601 : User Interface RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 igExpJj (June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0135 Page 2 of 2 APPROVAL: Listed as fire alarm control units for use separately listed compatible initiating and indicating devices. Also suitable for high-rise applications when used in conjunction with Model SKE-360 Voice-Tone Evacuation Unit (CSFM Listing No. 6912-0559:122); EVAX Audio Adjunct System Models EVAX-25 (CSFM Listing No. 06911-1446:100), EVAX-50 or EVAX-50E (CSFM Listing No. 06911-1446:102); EVX-2ZA or EVX-4Z Zone Splitters (CSFM Listing No. 06912-1446:101), HMX-MP or HMX-DP Voice Evacuation System (CSFM Listing No. 06911-1446:103), two-way firefighter telephone and separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Fomerly 7170-0559:0135 Rev. 04-26-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (ListipJjI (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division D SILENT KNIGHT by Honeywell (Model SD505-DU ~](an :SD505-D Detect smoke in air handling systems and prevent re-circulation with Silent Knight's addressable duct smoke detector The SD505-DUCTR addressable duct smoke detector detects smoke and products of combustion present in air moving through an HVAC air handling system. The SD505-DUCTR is a heavy duty metal housing with a pre-installed SD505-APS photoelectric smoke detector and relay module. When smoke is detected in a duct, the unit communicates the condition to the IntelliKnight control panel. The panel, in turn, depending on programming and wiring, turns off fans, blowers, and other devices. Now there's even more power and flexibility available to the lntelliKnight family of products. For more information on this product or to locate your nearest source, please call 800-328-0103. Model SD505-DUCTR Features Analog Duct Smoke Detector with Relay Module The Model SD505-DUCTR Addressable Duct Smoke Detector with Relay provides early detection of smoke and products of combustion present in air moving through an HVAC duct to prevent re-circulation of smoke into the air handling system. The SD505- DUCTR is a heavy duty metal housing with a pre-installed SD505-APS Analog Photo Electric Smoke Sensor and relay module. When smoke is detected in a duct, the unit communicates the condition to the lntelliKnight FACP. The built-in relay module, in turn, turns off fans, blowers, and other devices. Operation Air sampling is accomplished by two tubes which protrude into the duct. An exhaust tube of one standard length (7.5") is provided with the detector housing. Intake sampling tubes (ordered separately) are supplied in three standard lengths. Duct mounting is accomplished through a template and 4 sheet metal screws (provided). Two-wire connection to SLC Detects and limits spread of smoke LED alarm indication and communication on sensor head Rugged steel backbox with clear plastic cover Installation template included No screens or filters to clean SD505-APS Photoelectric Smoke Detector pre-installed 3 standard tube lengths UL listed, complies with NFPA 72 and 101 CSFM listed MEA Approved 429-92-E, Vol 9 FM Approved Specifications Physical Dimensions: 214 H x 9" L x 714" W Weight: 31bs Electrical Operating Voltage: 24 VDC Alarm Relay Contact rating: 10A@24VDC;10A@ 115 VAC; IOA@ 240 VAC Trouble Relay Contact Rating: 2.5A @ 30 VDC Aux. Power Input Current: 0mA Standby, 62 mA Ala LC !npt current 0.5 mA) (Max. SLS resistance: 50 Oh SD505-DUCTR SD505-DTS-K Environmental Operating Temp: 32°F to 100°F (0°C to 37°C) Humidity:10%-85% non-condensing Other Ratings: Air Velocity 300 - 4000 ft/mm Sampling Tubes: SD505-T2 2.5ft sampling tube SD505-T5 5ft sampling tube SD505-T10 lOft sampling tube Model SD505-DUCTR and SD505-DTS-K Duct Smoke Detector with Relay and Remote Test Switch Engineering Specifications The air duct smoke detector shall be Silent Knight Model SD505-DUCTR and remote test switch shall be SD505-DTS-K. The housing shall contain a Silent Knight model SD505-APS, Photoelectric Smoke Sensor. The duct detector shall be of metal construction. Complete mechanical installation must be able to be performed without removal of the detector cover. Terminal connections shall be screw type using a minimum of #6 screw. FACP/5815XL Connection DTS-K connection Class B (Style 4) D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.siIentknight.com MADE IN AMERICA FORM# 350005 Rev B Copyright © 2011 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0559:0163J Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: SlLENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN (Models 5D505 DUCT and SD505 DUCTR duct smoked e-tecitor units(S15505 DTS K remote,' (test switch.Each unit consists of a smoke detector head, plastic enclosure, plastic cover, relays, electrical components, and sampling and exhaust tubes. The smoke detector heads are not suitable for use as open area detection. Refer to listee's data sheet for additional, detailed product description and operational considerations. RATING: 120 VAC, 230 VAC, 24 VAC and 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as duct smoke detector units for use with separately listed compatible fire alarm control units to detect an abnormal amount of smoke density in the*supply air ducts of air conditioning and ventilating system. The air velocity in the duct shall be between 300-4000 fpm. NOTE: For duct application only. Not suitable for open area protection. XLF: 3240-0410:0155 06-28-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct * operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (Listing Expires- (June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ((xceder Strobe) Horn Strobe, and Horn Notification Appliances IFA,ILT*N Powering Business Worldwide Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Technical Data TDO01017EN Effective October 2014 Features Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 Audible settings 90, 95, 99 dB Industry leading-8 candela settings on 1 device Wall: 15/1575/30/75/95/110/135/185 Ceiling: 15/30/60/75/95/115/150/177 Universal mouting base Ceiling and wall Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base Contact cover rj Ii Common base for wall and ceiling with 5 mounting options Voltage test points for quick troubleshooting and easy spot checking (wall models only) HN Series HIS Series ST Series Environmentally friendly Low current draw Up to 9 models now in 1 appliance drawtD 12/24VDC on a single appliance Easy to remember model numbers D Patented Note: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range' All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance UL 1971, UL 464, ULC, CSFM, FM ADNNFPNANSI/OSHA RoHS 2 EATON www.eaton.com Model Legend HN = Horn R = Red ST = Strobe A = Agent Lettering (strobes only) HS = Horn Strobe AL = Alert Lettering (strobes only) C = Ceiling Mount N = No Lettering (strobes only) W = White Example 1: STRC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Fled, Wall Mount Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: 51W-AL = Strobe, White, Wall Mount, Alert Lettering 9iJ4 U. Example: HSWC Example: HSR HN Series Technical Data TDO01017EN HS Series Effective October 2014 ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 4VDC/24FWñ 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.183 0.182 - 0.205 - - 0.253 0.110 0.140 (sTc) 80330 0.061 - [0085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC UL Max Current® at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current® at Anechoic 95 dBA 24 VDC 12 VDC Regu g lated Voltage Model Rane VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0,153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current® at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model RangeVDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ® UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VOC for 24 VDC units). For unfiltered ratings, see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 Table 4. Specification & Ordering Information Model Strobe Candela Sync w/ DSM or Wheelock Power Supplies 12/24 VDC® Mounting Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UMB® HSW 15/1575/30/75/95/110/135/185 X X UMB® HSRC 15/30/60/75/95/115/150/177 X X UMB® HSWC 15/30/60/75/95/115/150/177 X X UMB® Strobes STR 15/1575/30/75/95/110/135/185 X X UMB® STW 15/1575/30/75/95/110/135/185 X X UMB® STRC 15/30/60/75/95/115/150/177 X X LIMBO (STwC) (15/3o/6oi75/95/1 5/150/177) (x (x) (UMB®) Horn HNR X X LIMBO HNW X X UMB® HNRC X X LIMB® HNWC X X LIMB® ® 12 VDC models feature 15 & 15/75 settings ® UMB = Universal Mounting Base EATON www.eaton.com 3 Technical Data TDO01017EN HN Series Effective October 2014 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shal produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where multi- candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com EJ'N Powering Business Worldwide Eaton Cooper Notification 273 Branchport Ave. Long Branch, NJ 07740 CooperNotif ication .com © 2014 Eaton All Rights Reserved Printed in USA Publication No. TDO01017EN October 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7125-0785:016) Page 1 of I CATEGORY: -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED) LISTEE: Cooper Wheelock lnc.7246 16th St. F., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: (ceder Series: Models i)strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) orLW a 'C' ma) (added for ceiling modeland/or a -NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110,135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not / an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 (une 30, 2-0 1-9) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division tCOi'TTRAC1O1{S IRE & CABLE Product Specification Issued: 1994 FIRE ALARM UNSHIELDED, RISER RATED IfrII - T NUMBER: FP41$ (DESCRIPTION:) (j/18 Solid FPLR Cable) CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. Construction Parameters: Conductor 18 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.010" Insulated Conductor Diameter 0.060" Number of Conductors 2 Nom. Lay Length 4.5" Jacket Material PVC Jacket Thickness 0.020" (Nom. Overall Cable Diamete! Approximate Cable Weight (lbs.IKft.) 20 Flame Rating UL 1666 riser flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 201C 6.43 Ohms/Kft. nom. Capacitance Between Conductors @ I KHz 35 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 C to 60 C Insulation Colors Chart 2 Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT EX6418X (UL) 18AWG TYPE FPLR DEVICE A B C D E F ZONE 0 12 3456 789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Contractors Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Contractors Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: August 20, 1994 CONTRACTORS WIRE & CABLE 6611 Preston Ave Ste A Livermore, CA 94551 Ph: (800) 444-8816 Fax: (925) 454-3444 WWW. Co n t r a c t o r s w i re .com ICONTRACFORS WIRE & CABLE Product Specification Issued: 1994 FIRE ALARM JACKETED UNSHIELDED (PART NUMBER: FPL114j (iCRIPTION:) (I14 Solid FPLR Cable) CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and NEC Article 760. APPLICATION: Power Limited Fire Alarm Circuit Cables. Construction Parameters: Conductor Stranding Insulation Material Nom. Insulation Thickness Insulated Conductor Diameter Number of Conductors Nom. Lay Length Jacket Material Jacket Thickness Overall Cable Diameter) Approximate Cable Weight (lbs.IKft.) Flame Rating 14 AWG bare copper Solid PVC 0.015' 0.094" 2 5.0" PVC 0.025" 40 UL 1581 vertical tray flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 20C 2.52 Ohms/Kft. nom. Capacitance Between Conductors © I KHz 40 pFlft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 °C to 60 °C Insulation Colors Chart 2 Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT EX6418X (UL) 14AWG TYPE FPL DEVICE A B C E E F ZONE 0 12 3456789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Contractors Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Contractors Wire & Cable. Customer Name Signed Customer Approval Specification Issue Date: August 20, 1994 XONTRACTORS IRE & CABLE 6611 Preston Ave Ste A Livermore, CA 94551 Ph: (800) 444-8816 Fax: (925) 454-3444 www.contractorswire.com (iONTRAC'1'OILS WIRE & CABLE Product Specification Issued: 1994 FIRE ALARM JACKETED UNSHIELDED FPL1 150 (?ART NUMBER: FPL11503 (.IDESCRIPTION7) (I12 Solid FPLR ci) CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and NEC Article 760. APPLICATION: Power Limited Fire Alarm Circuit Cables. Construction Parameters., Conductor 12 AWG bare copper Stranding Solid Insulation Material PVC Nom. Insulation Thickness 0.015" Insulated Conductor Diameter 0.110" Number of Conductors 2 Nom. Lay Length 5.5" Jacket Material PVC Jacket Thickness 0.025" (Nom. Overall Cable Diamj Approximate Cable Weight (lbs.IKft.) 65 Flame Rating UL 1581 vertical tray flame test. Electrical Properties: Nom. DC Resistance per Conductor @ 201C 1.59 0hms/Kft. nom. Capacitance Between Conductors @ I KHz 45 pF/ft. nom. Operating Voltage 300 V RMS max. Temperature Rating -20 'C to 60 'C Insulation Colors Chart 2 Jacket Color Red (Other colors are available) Legend (Surface Ink Print) ***FT EX6418X (UL) 12AWG TYPE FPL DEVICE A B C 0 E F ZONE 0 12 3456 789 Cable has a rip cord for easy jacket removal. The jacket is sequentially foot marked. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise. This specification is proprietary intellectual property of Contractors Wire & Cable. Any information contained herein shall not be disclosed to any party without written consent of Contractors Wire & Cable. Customer Name Date Signed Customer Approval Specification Issue Date: August 20, 1994 CONTRAC'I'ORS WIRE & CABLE 6611 Preston Ave Ste A Livermore, CA 94551 Ph: (800) 444-8816 Fax: (925) 454-3444 www.contractorswire.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7161-1505:0100) Page 1 of 1 CATEGORY: (7161 -- CABLES-FIRE PROTECTIVE SIGNALWJ) LISTEE: (JINAN PAC CABLE & WIRE COMPANY248 Avenida Victoria, Unit A, San Clemente, CA 92672 Contact: Christoper "Derek" McMullen (949) 531-8996 Email: derek.mcmullen1gmail.com DESIGN: Power Limited Fire-Protective Signaling Cable, Type FPL, FPLP andFPLRRefer to listee's data sheet for additional detailed product description and operational considerations. Insulation: PVC, SRPVC with minimum average thickness of 6 mils, minimum at any point at 5 mils; PVC compound Apex 910 with minimum average thickness of 6 mils, minimum at any point at 5 mils, maximum average thickness at 14 mils. *PVC compound Teknor Apex 96-A025A-115 with mm. average thickness 6 mils, mm. at any point 5 mils. Shield (Optional): Aluminum/polyester tape. Core Wrap (Optional): Polyester tape, 2 mils thick max. Jacket: PVC compound Teknor Apex 4128, PVC Compound Apex 910, and *PVC Compound 90-A033A-10 INSTALLATION: In accordance with listee's printed installation instructions, NEC Article 760, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Type FPL, FPLP or *FPLR and UL label. APPROVAL: Listed as a power-limited fire protective signaling cable. *Rev. 11-14-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Ds (June 30, 2019) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division