Loading...
HomeMy WebLinkAbout951 PALOMAR AIRPORT RD; ; AS160211; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160211 951 PALOMAR Job Address: Status: ISSUED AIRPORT RD Permit Type: SPRINK Applied 7/5/2016 Parcel No: 2110403600 Approved: 7/18/2016 Lot #: 0 Reference No.: Issued: 7/18/2016 PC #: Inspector: Project Title: COSTCO CARLSBAD THREE AREAS FOR THIS SPRINKLER T.I. Applicant: CJ SUPPRESSION, INC. 205 LEWIS CT CORONA, CA 951-735-5560 Owner: COSTCO WHOLESALE CORPORATION PROPERTY TAX DEPT 462 999 LAKE DR ISSAQUAH WA Fees ($) Add'l Fees ($) I Total ($) Balance ($) 303 0 303 0 FM Approved and Fully Listed Sprinkler Pipe Wheatlands Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6' receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES in mm in. mm in. mm lbs/ft. kg/rn CRR Lift 1'/ 1.660 42.2 1,442366 .109 2.77 181 2.69 7.3 61 11/ 00 48.3 168. 42.7 10 2.09 3 56 6 2 2.375 60.3 2.157 54.8 06 7 7" 2.64 3.93 4.7 3" 2¼ 2 875 73.0 Z.635 66.9 .120 Z,053.53 5,26 15 30 3 500 8&9 3260 828 120 105 4.34 646 26 19 .4 4500 1143 4,2601082 120 3,0E o 83" 1,6 19 5 5.563 1.3 5.295 134.5 .!,)4 3.40 7.78 1158 1. 5 13 6 6.625 1683 6,357 161 34 3.-.0 9.30 13.85 10 10 8 8.625 219.1 8.249 2098 .188 4.78 16.96 25.26 2.1 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES iii. mm In. mm In. mm lbs/ft. kg/nn cpe Lift 1 1,315 3-1,A 1.049 26.6 13 --1.38 1.68 2.70 1.00 70 11/4 1.660 4.2 1.380 35.1 40 3.56 2.2" 3.39 1,00 51 11/2 1,900 483 1.610 409 145 3,68 272 405 100 44 2 2.375 603 2077 52." 1 "9 361 5.145 1.00 30 Calculated using Standard UL CRR formula, UI. Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). @ C < PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: AS 160211 El BLACK HOT-DIP GALVANIZE[ 951 PALOMAR AIRPORT RD '1dTube L . ---- .---- Fig. 24 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe Double Fastener Strap Side Mounted (Cooper B-Line 133183) ..; 1.0$ Size Range: 3/4".(20mm) thru 2" (50mm) CPVC pipe . 'IJSTED. Material: Pre-Galvanized Steel . Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom - - - ofabeam. - Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4 x 1 tek type screws. Meets and exceeds the requirements of - NFPA 13,13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and . ease installation. The flared edge design protects the CPVC pipe from .. I any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the I product. It is recommended that rechargeable electric drills fitted with I a hex socket attachment be used as installation tools. No impact •. L tools (such as a hammer) are allowed. Damage has been known to 0 result from installations using impact type tools. No pre-drilling of a L pilot hole in wood is required. s Finish: Pre-Galvanized " " B Order By: Figure number and pipe size A *_Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. With reduced spacing, consult factory. 24-/4 CPVC Pipe 3/4 Size (20) 2I16" A (58.7) 1I32 B (27.8) 1/16" G (30,2) Max. Hanger Spacing 51/2 (1.67) Fastener Head 5/16" Hex Size (7.9) 9 Approx. i wt./i 00 (4.1) 24-1 1" (25) 2/8 (66]) 1/6" (33.3; 1/16" (30]) 6 (1.83) /16' (7.9) 9 (4.1) 24_11/4 11/4'1 (32) 3" 76.2 11/2 (38.1) 1/16 (30.2) 91/7 (1.98) 16 (7.9) 11 (5.0) 2411/2 11/2 (40) 31/4 (32.5) 1I8" 43.3) 1/16 (30.2) 7 (3.13) /16 (7.91 12 (54) 24-2 2" (50) 311/16 (93.7) 1 127/32" (43.6) 1I16" 1 (30.2) 8 (2.44) /16" (7.9) 1 15 (6.8) Fig. 25 - Surge Restrainer rh O&S o Size Range: — One size fits 3/4' (20mm) thru 2" (40mm) pipe. LISTED 3 Material: - Pre-Galvanized Steel S i Function: — Designed to be used n conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler ,. head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on f :1 the band hanger. This product is intended to satisfy the requirements ... as indicated in the National Fire Protection Association NFPA 13 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe Approvals: — Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). / Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4 (20mm) thru 2" (40mm). - Patent #5,344,108 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. p.-.- COOPER B-Line 44 Fig. 200-1/2.20D-3/4 Fig. 200-21/2 to 200-8 Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B3170NF) Fig 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B Line Fig B317ONFF) Fig 200C - Trimline Adjustable Band Hanger with Plastic Coated (B Line Fig B311ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" 115mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8' (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" )20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1l 92A, Type 10 .and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) -Finish: Pre-Galvanized. Stainless Steel r"nateria(s will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Fig. 200-1 to 200-2 —p Fig. 200F Pipe Size Rod Size A B Approx. Wt.I100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200 1/2 /2 15) 3/8,1-16 31/1 (794) 2/8 (667) 11 (50) 200-/4 3/4' 20) /8'-15 31/0 79.4) 272 (635) 11 5.0) 2001 1 25) /t 16 3/8 (057) 278 (667) 12 (55) 200-1I4 174' (32) 3/8'_ 16 33/4 (94.0) 2/8 (73,0) 13 (5.9) 200-11/2 172 40) 3N-16 378 (984) 27/8 (70) 14 (64) 200-2 2 (50) I8'-16 41/2' 114.31 3 (76,3) 15 (6.91 20021/2 21h (65 /8 "-16 5I8 142 9) 41/8 (1047) 27 (123) 200-3 3" (75) 3/8'16 57/3 149.1) 4" 101.6) 29 (13.3) 200-31/2 31j (90) 3/8"-16 7/s (1873) 51/4 (13.) 34 (156) 200-4 4" (100) /'-16 73/8' (107.3) 5" (127.0) 35 (160) 200-5, 5 1125) 1/2"-13 91/8 (231,M 61/4 (1507) 66 (302) 200-6 6" (150) 1/2'_13 101/8 (257.2) 6/4' (171.4) 73 (334) 200-8 6 (202) 1/2"-13 131Jo (3334) 8/4 (2222) 136 (6231 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions B-Line Wood Flooding No pre -drilling required Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Wood Joel . Saves time from traditional _____________ • methods. Double Sheevock - Ceiling Reduces installation costs. Made in the U.S.A. (.7 darmirabon -. www.itwbulldex.com) "A a MM YT FOM WO OD nn!kafir, 4 8002957 GST 100 1/4x1" 25 125 8003957 CST 200 1/4x7 1760 (H( 25 - 125 1 8004957 GST 300 14 x 3 2060 (H 25 125 J5-8007957 ST 10 1/4 xl 210 )7J1xOSB( 300 25 12 29 8008957 GST 20 1/4 x 2 1760 (Or) 850 1475 25 125 8068925 GOT 20-OS 14 x 2 1760 (Ar) 850 25 125 2 8009925 GST25-380 38x2 1/2 2111 (Hi) 100 25 125 #14 Black Q. <> CS 8010957 GST 30 1t4 x 3 2060 (Fir) 1500 1475 25 12 Nut Driver 17 806992 30-SS 1/4 x 3 2060 (Or) 2 125 Part #8113910 8011925 GST 11 1/4 x 4 2180 (F/i) -- 25 125 W '2' 8013925 GOT 2 1/4 x2 1760 (Fir) , , - 25 125 Jj 7' -. 8014925 .,ST2 5-380 3/8x2-1/ 114-x 3' 2113 (Fir) 25 125 P. 8015925 GST 3 2275 (Fir) 25 125 #14 SW Red Not Driver Part #8114910 Elm MeeEINU.s.A OHS . SPECIAL NUT DRIVER SYSTEM: The nut drivers were cesigned with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue driling until not driver spins free. Installation is then complete. Warranty reqLires the use of the appropriate nut driver for installations, tqCI3 Fire Suppression & Building Products Technical Services 800-381-9312 I +1-401-781-8220 www.tyco-fire.com Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Standard Response (5 mm Bulb) and Standard Coverage, are decorative glass bulb automatic sprin- klers typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures; for example, sprinkler drops from unheated portions of buildings sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures; for example, sprinkler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors sprinklers are used on systems that are seasonably drained to avoid freezing; for example, vacation resort areas NOTICE Series DS-1 Dry-Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association, in addition to IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 the standards of any. other Authorities Having Jurisdiction. Failure to .do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers (SlNs TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved LPCB Approved: Ref No. 094a/11 CE Certified: EN 122.59-1 NYC Approved under MEA 352-01-E Refer to Table A. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1-inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient K = 5.6 GPM/psi112 (80,6 LPM/bar1'2) Temperature Ratings Refer to Table A. MAY 2011 Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated, Chrome Plated, Brass Plated Physical Characteristics Inlet.....................Copper Plug ....................Copper Yoke ..............Stainless Steel Casing ...............Galvanized Carbon Steel Insert ...................Bronze Bulb Seat ..........Stainless Steel Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze Frame ...................Bronze Guide Tube.........Stainless Steel Water Tube .........Stainless Steel Spring.............Stainless Steel Sealing Assembly. . . Beryllium Nickel w/Teflon Escutcheon ..........Carbon Steel *DuPont Registered Trademark TFP500 TFP500 Page 2of10 TY3255 Pendent TY3055 Pendent TY3355 Horizontal Sidewall with top of Deflector-to-Ceiling with Standard with Standard Escutcheon distance of 4 to 12 inches Recessed Escutcheon. . (Figure 5) . . (100 to 300 mm) (Figure 3) with Wide Flange with Deep Escutcheon with Standard Escutcheon Recessed Escutcheon . (Figure 6) . (Figure 9) (Figure 4) without Escutcheon with Deep Escutcheon Temperature Bulb Color (Figure 7) .. . . (Figure 10) Rating Code TY3155 Upright without Escutcheon (Figure 13) without Escutcheon (Figure 8) SPRINKLER FINISH Natural Chrome White Natural I Chrome White Natural Chrome I White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F (57°C) Orange 1,23,5 1,2,5 1,2,3,4,5 1,2,4,5 1*,2*,3**,4,5 1*,2*,4,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue N/A 4, 5 360°F (182°C) Mauve N/A 1*, 2*, 5 N/A Notes Listed by Underwriters Laboratories, Inc. (maximum order 4. Loss Prevention Certification Board and CE conformity length of 48 inches) . apply to these temperature ratings only Listed by Underwriters Laboratories for use in Canada 5. Approved by the City of New York under MEA 352-01 -E (maximum order length of 48 inches) Light and Ordinary Hazard Occupancies Only Approved by Factory Mutual Research Corporation °° Light Hazard Occupancies Only (maximum order length of 48 inches) N/A - Not Available TABLE A SERIES DS-1 STANDARD RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS -LABORATORY LISTINGS AND APPROVALS - PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING INLET BAND WATER II II TUBE CASING GUIDE - INSERT TUBE BULB FRAME SEAT 5 m BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS- I STANDARD RESPONSE DRY-TYPE SPRINKLERS - ASSEMBLY - WRENCH RECESS WRENCH'g FLAT 0 20 PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 SPRINKLER WRENCH SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER \ FITTING ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS MINIMUM 1-3/4(44,5mm) - DEFLECTOR TO CEILING TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING TFP500 Page 3 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING - ORDER LENGTHS 2-3/4 to 48" 1-3/4 DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4(6,4mm) INCREMENTS FACE OF CEILING 2-3/16 ± 1/8 DIA. (55,6 ± 3,2 mm) (76,2 mm) FIGURE 3 PENDENT TY3255 WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER \ FIT ORDER LENGTHS: 3-3/4k to 48" (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4' DIA. INCREMENTS (57,2 mm) FACE OF CEILING 1-3/8±1/8 2-7/8" DIA. (34,9 ± 3,2 mm) - (73,0 mm) FIGURE 4 PENDENT TY3255 WITH STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER.. FITTING , LIIp ORDER LENGTHS: 3-1/2' DIA. 1/2" to 46" (88,9 mm) (12,7to1168,4mm) 2-1/2" DI INCREMENTS RE, Nrl FACE OF CEILING 1/8" (108.0±3,2 mm) FIGURE 5 PENDENT TY3255 WITH DEEP ESCUTCHEON FIGURE 6 FIGURE 7 PENDENT TY3255 UPRIGHT TY3155 WITHOUT ESCUTCHEON WITHOUT ESCUTCHEON (76,2mm) SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16' CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 8 TY3355 HORIZONTAL SIDEWALL WITH STANDARD ESCUTCHEON ORDER LENGTHS: 2-3/4 to 48' (69,9 to 1219,2 mrn) IN 1/4 (6,4 mm) INCREMENTS FACE OF FACE OF SPRINKLER MOUNTING - FITTING SURFACE 4±1/8 (101,6 ± 3,2 mm) 1-3/4 DIA. (44,5 mm) TFP500 Page 4 of 10 Operation ' . When TYCO Series DS-1 Dry-Type Sprinklers are in service, water 'is prevented from entering the assembly by the Plug with Sealing Assembly (Figure 1) in the Inlet of the Sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the. fluid expands sufficiently to shatter the glass bulb, and the BUlb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allowing the sprinkler to activate and flow water. Design Criteria ORDER LENGTHS: FACE OF 1/2' t045-3/4"(12,7to1162,1 mm) MOUNTING IN 1/4' (6,4 mm) INCREMENTS SURFACE 4-13/16' ± 1/8' (122,2 ± 3,2 mm) FACE OF 2-1/2' DIA. (63,5 mm) SPRINKLER - FITTING - 3-1/2 DIA. (88,9 mm) F3.5' SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3355 HORIZONTAL SIDEWALL WITH DEEP ESCUTCHEON ORDER LENGTHS: 5-1/2" to 48' (139,7 to 1219,2 mm) IN 1/4'(6,4 mm) INCREMENTS MINIMUM 2-1/4' (57,2 mm) L FACE OF DEFLECTOR TO SPRINKLER MOUNTING URFACE SURFACE SPRINKLER FITTING /(7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 10 TY3355 HORIZONTTAL SIDEWALL WITHOUT ESCUTCHEON TYCO Series DS-1 Dry-Type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL - Listing is based on NFPA 13 require- ments. For more information on LPCB Approval, contact TYCO Fire Suppression & Building Products at the following office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1-inch NPT Series DS-1 Dry-Type Sprinklers are to be installed in the 1-inch NPT outlet or run of the following fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125). Do not install Series DS-1 Dry-Type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. You can also install Series DS-1 Dry-Type Sprinklers in the 1-inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. TFP500 Page 5 of 10 Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area' 40°F (4°C) 50°F (10°C) 60°F (16°C), Minimum Exposed Barrel Length, Inches (mm)2 40-F (4-C) 0 0 0 30'F (-1-C) 0 0 0 20°F (-7°C) 4 (100) 0 0 10-F (-12-C) 8(200) 1(25) 0 0-F (-18-C) 12 (305) 3(75) 0 -10°F (-23°C) 14 (355) 4 (100) 1 (25) -20°F (-29°C) 14 (355) 6 (150) 3(75) -30°F (-34°C) 16 (405) 8 (200) 4 (100) -40°F (-40°C) 18 (455) 8 (200) 4(100) -50°F (-46°C) 20 (510) 10 (255) 6 (150) -60°F (-51°C) 20 (510) 10 (255) 6 (150) Notes For protected area temperatures that occur between values listed above, use the next cooler temperature. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE B EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS - MINIMUM RECOMMENDED LENGTHS - The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Typo Sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of 1-inch NPT Series DS-1 Dry-Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: 1" x 1" NPT Female Adapter (P/N 80145) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249). For dry pipe system installations, use only the side outlet of maximum 2-1/2- inch reducing tee when locating Series DS-1 Dry-Type Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. L!I.)tLg4 Do not install Series DS-1 Dry-Type Sprinklers into any other type fitting without first consulting the Technical Services Department. Failure to use the appropriate fitting may result in one of the following: Failure of the sprinkler to operate prop- erly due to formation of ice over the Inlet Plug or binding of the Inlet Plug. Insufficient engagement of the Inlet pipe-threads with consequent leakage. Drainage In accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing temperatures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table B to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the connecting pipes due to conduction. The exposed barrel length measure- ment must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when connecting an area subject to freezing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and subsequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. TFP500 Page 6 of 10 RUN OUTLET PLUGGED SPRINKLER FITTING TO DRY (SEE DESIGN SYSTEM CRITERIA SECTION) rr I INTENDED FOR FREEZER I STRUCTURES FIGURE 12 SPRINKLER FITTING - UNHEATED AREA - FACE OF SPRINKLER - - FITTING . ' EXPOSURE LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES FIGURE 11 - EXPOSURE LENGTH - TO WET SIDE SYSTEM OUTLET ri PLUGGED mum )II1I1E1' \ DSB-2 SPRINKLER INTENDED FITTING FOR FREEZER (SEE DESIGN STRUCTURES CRITERIA SECTION) FIGURE 13 SPRINKLER FITTING - HEATED AREA - STRAP TIES OPPOSING SIDES OF (ENDS ON BOOT) J ADHESIVE _--DSB-2 BOOT ( DIA. (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY-TYPE SPRINKLER 1-3/4 DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE BOOT STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER TFP500 Page 7 of 10 Installation TYCO Series DS-1 Dry-Type Sprinklers must be installed in accordance with the following instructions. NOTICE Series 'DS-1 Dry-Type Sprinklers must only• be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 360°F (182°C) rating. Obtain a leak-tight 1-inch NPT sprinkler joint by applying a minimum-to- maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of .torque may distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over- tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Install pendent sprinklers only in the pendent position; install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprinkler is to be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their centerline of waterway perpendic- ular to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. With a non-hardening pipe-thread sealant such as Teflon applied to the Inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Wrench-tighten the sprinkler using either: a pipe wrench on the Inlet Band or the Casing (Figure 1). the W-Type 7 Sprinkler Wrench on the Wrench Flat (Figure 2). Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal • is easier when a non-hardening sealant was used and torque guide- lines were followed. After removal, inspect the sprinkler for damage. 4. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling! wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-1 Dry-Type Sprinklers must be maintained and serviced in accordance with the following instructions. NOTICE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protection system control valve and drain the system before removing the sprinkler. Exercise care to avoid damage before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never, repaint factory-painted Cover, Plates'. When" necessary, replace cover plates with factory-painted units. Non-factory applied paint can adversely delay or prevent sprinkler operation in the event of a fire. Replace sprinklers that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. were modified or over-heated. have cracked bulbs or have lost liquid from the bulbs. Refer to the Installation Section in this data sheet. are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other Authorities Having Jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. DuPont Registered Trademark TFP500 Page 8 of 10 15 Limited Warranty Products manufactured by Tyco Fire Suppression and Building Products (TFSBP) are warranted solely to the original Buyer against defects in material and workmanship when paid for and properly installed and main- tained under normal use and service. This warranty will expire twelve (12) months from installation or eighteen (18) months from delivery, whichever occurs first. No warranty is given for products or components manufac- tured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper instal- lation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with appli- cable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be respon- sible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possi- bility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a partic- ular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name, including description and Part Number (PIN). Dry Sprinklers When ordering 5.6 K-Factor Series DS-i, Standard Response , Standard Coverage (5 mm Bulb), Dry-Type Automatic Sprinklers, specify the following information: Model/SIN Pendent TY3255, Upright TY3155, or Horizontall Sidewall TY3355 Deflector Style Order Length Dry-Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 10, as applicable. After the measurement is taken, round it to the nearest 1/4 inch increment. Inlet Connections i-irch NPT or ISO 7-R1 Temperature Rating Sprinkler Finish Escutcheon Style and Finish, as applicable Part Number from Table B. Part numbers are for i-inch NPT standard order sprinklers. Orders for all other sprinkler assemblies must be accom- panied by a complete description. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002. This Part Number includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive (a suffi- cient quantity for installing one boot). TFP500 Page 9 of 10 1 P/N* 60 — XXX — X - XXX MODEUSIN SPRINKLER ESCUTCHEON FINISH FINISH (1) 96 Pendent with Standard TY3255 1 NATURAL BRASS WHITE — Escutcheon (1 " NPT) (Figure 3) Pendent with Deep TY3255 4 WHITE POLYESTER WHITE Escutcheon (1' NPT) (Figure 5) 97 Pendent with Standard TY3255 9 CHROME PLATED CHROME Recessed Escutcheon (1" NPT) (Figure 4) 92 Pendent without Escutcheon (1" NPT) 1Y3255 (Figure 6) 0 CHROME PLATED WHITE _F 2 NATURAL BRASS BRASS PLATED 94 Sidewall with Standard TY3355 Escutcheon (V NPT) (Figure 8) 53 Sidewall with Deep TY3355 Escutcheon (1" NPT) (Figure 9) 54 Sidewall without TY3355 Escutcheon (1° NPT) (Figure 10) 0 135°F (57°C) 98 Upright without TY3155 1 155°F (68°C) Escutcheon (1° NPT) (Figure 7) 2 175°F (79°C) Notes 3 200°F (93°C) * Use Prefix "I" for ISO 7-R1 Connection; for example, 1-60-961-1-180). 4 286-F (141-C) 1. Escutcheon Finish applies to sprinklers provided with escutcheons. 5 360°F (182°C) O ',Qc°c (1fl1°C'\ ..,,l '(l° u100°(' +,m,+, - 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00' TEMPERATURE ORDER RATING (2) LENGTH (3) UI tA flJIJ I IJ. '1.1/ t.—H—. o afr,JIy to non-recessed sprinkler assemblies. 3. Dry-Type Sprinklers are, furnished based upon "Order Length" as measured per Figures 3 through 10, as appli- cable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. TABLE C SERIES DS- I STANDARD RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS — PART NUMBER SELECTION — Copyright 0 2007, 2011 Tyco Fire Suppression & Building Products. All rights reserved. W Contacts orldwide www.tyco4ire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage : General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. -The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a -finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2 NPT TY323 ......Pendent 5.6K, 1/2 NPT Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/ps11/2 (80,6 LPM/bar112) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) JANUARY 2013 Finishes Sprinkler: Natural Brass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2 of 4 Components * Temperature rating is .**:Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16' (11,1 mm) Assembly 6 - Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON NOMINAL (50,m i:v (50,8 mm) WRENCH L FLATS 1 1/2" NPT** DEFLECTOR* 2-7/8 (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (Y313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323)' Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. WRENCH RECESS (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Peñdent Sprinklers The, Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- -kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and• Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 27/8 DlA (73,0 mm) 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) \ _l FLUSH 3/8±5/16" i I (9,5±7,9 mm) I L MOUNTING SURFACE N - \(3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34.9 mm) TYFRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON - 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4 DIA. FITTING (57,2 mm) 5/16±1/4' 1/2 (12,7 mm) (7.9±6,4 mm) FLUSH 1/8 J MOUNTING \ SURFACE (3,2 mm) / CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TY.FRB PLATE 7/8' (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 PIN* 77 - XXX - X - XXX SPRINKLER TEMPERATURE FINISH RATINGS SIN 370 5.6K UPRIGHT (lIZ NPT) TY313 371 5.6K PENDENT (1/ZNPT) TY323 * Use suffix '1° for ISO 7-1 connection; for example, 77-370-4-175-I 1 NATURAL BRASS 4 SIGNAL WHITE (RAL 9003) 3 PURE WHITE (RAL 9010)°° 9 CHROME PLATED Eastern Hemisphere sales only 135 135°F (57°C) 155 155°F(68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS - PART NUMBER SELECTION - Ordering• Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (SIN), K=5.6, (Upright or Pendent) Sprinkler Quick Response, (specify) temperature rat- ing, (specify) finish, P/N (Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright© 2013 Tyco Fire Products, LP. All rights reserved. *tqco TEFLON is trademark of The DuPont Corporation. ® J ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS AreLock® Cu1etT STYLE 922. The Style 922 outlet-T provides a convenient method of incorporating ½, '/~, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Available for 11A through 16 .1, mm/32 to 76.1 mm piping systems Style 922 outlets are UL/ULC Listed, 1-PCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes. It is supplied with a clear, rust inhibitive coating. Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395. grade 65-45-15, is available upon special request, Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date________________________________ www.victaulic.com . vic'rsuLlc IS REGISTERED TRADEMARK OF VICTAIJLIC COMPANY. © 2009 vICTAULIC COMPANY. ALL RIGHTS RESERVED, ictauliice REVF 10.521 PS CARBON STEEL PPE HOLE CUT PRODUCTS 10.52 FreLock® OuUetT STYLE 922 'r DIMENSIONS 1.0 : 30.2 4)5 27.9 983 sb,O 0.50 30.2 K 1536 142 19 122 408 25o .2 302 36 895 31,0 1036 i 650 054 131116 1.40 1,95 122 4.08 256 302 35.6 495 31.0 103.6 650 0.58 '16 1.64 230 122 08 2.6 1.3 302 417 584 31.0 036 650 0.5° 1,46 1.66 210 1.46 4.60 256 3 30.2 42.2 35 6 37 116.8 650 0,29 1i4 64 219 146 460 256 1.4 30.2 417 35,6 371 I 68 65C 064 13/16 88 254 146 460 2.6 5 30.2 478 645 37.1 116.8 6°L 06e 1 191 244 5.40 256 '6 30.2 48,5 62.0 434 7.2 65.0 0.73 15,4 185 244 1.71 540 256 1.6 30.2 480 620 43.4 37.2 650 0.73 1-i' 2.13 279 '71 540 256 1.6 30.2 54, 703 433 '372 650 , , 073 13,11, 191 2.44 171 550 250 1.6 302 485 620 434 17 65.0 073 13/,6 189 244 1.71 550 236 16 30.2 48.0 620 434 139 / 65.0 073 1 7 3 2.79 11 5.50 1% 17 75 302 5'1 709 4.3.4 1397 650 080 i Vicrauhc female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only, Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc, should be yenned as suitable for use with this Victauhc product Failure to verify suitabilitv ii advance may result in assembly problems or leakage. *Center of un to engaged pipe end for NFTF threads (dimensions are approximate) www.victaulic.com -III./ic-tau I i VIcTAULIC 1S REGISTERED TRADEMARK OF vIcTAuLlc cOMPANY. © 2009 vicTAuLic COMPANY. ALL RIGHTS RESERVED. 1D522 RSVP IPS CARBON STEEL PIPE - HOLE CU1PRODUCTS 10.52 FireLock® Outlet-l" STYLE 922 PERFORMANCE Equivalent Len, Run Size 1!1fll :tion 16, 8.5 2.6 8.5 2.6 8.5 SC 2, 2.6 65 25 2.6 IUrr 2 8.5 Hazen-Williams coefficient of friction is 120 www.victauIic.com VICT.AIJLIC IS A REGISTERED TRADEMARK OF VICTALILIC COMPANY. © 29 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV .F xkct~~—U,5 10523 STYLE 922 INSTALLATION •.: : .. Reference should aiwaysbe made to the 1-100 Victaulic Field Installation Handbook for the product• you are instalhng Handbooks are induced with each thiment of Victaulic products for complete installation and assembly data and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information visit www.victaulic.com 10.52 3355 REV F UPDATED 2/2009 ictaulid VICTAUUC S A REGISTERED TRADEMARK OF '/ICTAULIC COMPANY.© 2009 VICTAuLiC COMPANY. ALL RIGHTS RESERVED. 1052