Loading...
HomeMy WebLinkAbout5791 VAN ALLEN WAY; ; FPC2020-0209; PermitPERMIT REPORT 4L-Cltyof Carlsbad Print Date: 05/07/2021 Permit No: FPC2020-0209 Job Address: 5791 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121304500 Track #: Applied: 12/17/2020 Valuation: $150,000.00 Lot #: Issued: 04/16/2021 Occupancy Group: Project #: Finaled Close Out: 05/07/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check#: Final Inspection: Project Title: Description: THERMO FISHER SHARED LAB - FIRE ALARM TI (ADDRESSABLE, 10 DEVICES) FPContractor: JOHNSON CONTROLS SECURITY SOLUTIONS LLC P0 BOX 3042 BOCA RATON, FL 33431-0942 (561) 226-8210 FEE AMOUNT FIRE Hourly Services Each Additional Hour $136.00 FIRE Hourly Services First Hour $159.00 FIRE TI Fire Alarm System $620.00 Total Fees: $915.00 Total Payments To Date: $915.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov EXISTING REF. ONLY DF-60334:A6•A1-100 M S'9600 LS( E )IMS"9600U DLS( E) j sire uTeALarms Intelligent Addressable FACP by Honeywell with Optional Second Loop Fire-Lite's MS-9600LS(E) and MS-9600UDLS(E) are compact, cost effective, intelligent addressable FACPs (Fire Alarm Control Panels) with an extensive list of powerful features. The combination of Fire-Lite's newer series devices and legacy 300 Series devices, along with the MS-9600LS(E) or MS-9600UDLS(E) FACP, offer the latest in fire protection technology. LiteSpeedTm is a patented tech- nology that polls 10 devices at a time looking for new or different information. When new information is found at a specific address, the system polls that device several times for any new data. This improvement allows a fully loaded panel with up to 636 devices to report an incident and activate the notification circuits in under 10 seconds. With this polling scheme, devices can be wired on stan- dard twisted, unshielded wire up to a distance of 10,000 feet per loop. Each Signaling Line Circuit (SLC) loop supports up to 159 addressable detectors including photoelectric, photoelectric with heat, beam, ionization, photoelectric duct, fixed heat, fixed heat with rate-of-rise, and fixed high-heat detectors. It also supports up to 159 addressable modules including monitor (two-wire detector, normally open devices), dual-monitor functions (two monitor circuits from one module, two addresses used), multi-monitor (multiple monitor cir- cuits from one module, multiple addresses used), control (for Notifi- cation Appliance Circuits), and relay (two Form-C) modules. The FLPS-7 power supply is a separate board while all other elec- tronics are contained on a single main circuit board. Both boards are mounted to a quick-removable chassis and housed in a metal cabi- net. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the chassis with the electronics can be quickly installed with two bolts. The MS-9600UDLS(E) includes a factory-installed 2 Digital Alarm Communicator Transmitter. The DACT transmits system status (alarm, troubles, AC loss, etc.) to a Central Station via internet (optional IPDACT installed) or the public switched telephone net- work. Optional modules, which plug into the main circuit board, are avail- able for special functions. Available accessories include LED, graphic and LCD annunciators, reverse polarity/city box transmitter, digital alarm communicator/transmitter, SLC expansion module, local and remote upload/download software and remote power expansion. FM APPROVED to UL ANSI 864. NOTE: Unless otherwise specified, the term MS-9600LS is used in this document to refer to the MS-9600LS, MS-9600UDLS, MS-9600LSE, and MS-9600UDLSE FACPs (Fire Alarm Control Panels). Controls And Indicators LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCE/PRESIGNAL (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) MEMBRANE SWiTCH CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 12-key pad with full alphabet 4 cursor keys ENTER Special Features Easy mount chassis. 7 amp switching power supply. Large enclosure allows 18 amp-hour batteries 2 plug-in communicator standard with MS-9600UDLS/E. Optional IPDACT Internet Protocol Digital Alarm Communicator/ Transmitter Four Style Y (Class B) or two Style Z (Class A) NAC circuits. Selectable strobe synchronization per NAC for System Sensor, Wheelock, and Gentex devices. Certified for seismic applications when used with the appropriate seismic mounting kit Seamless integration between fire and mass notification with the ECC-50/100 Emergency Command Center via ANN-BUS con- nections. ECC-FFT Firefighter Telephone Option ANN-BUS for connection to following optional modules Note: cannot be used if ACS annunciators are used. —ANN-80(-W) Remote LCD Annunciator - ANN-I/O LED Driver Module - ANN-S/PG Serial/Parallel Printer Module DF-6034:A6 2/20/2019 - Page 1 of 6 - ANN-RLY Relay Module - ANN-LED Annunciator Module - ANN-RLED Annunciator Module (alarms only) Compatible with SWIFT® wireless devices Standard Features SLC LOOP SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 318 addressable devices per loop (159 detectors and 159 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,048 m) @ 12AWG (3.1 mm') using twisted, unshielded wire (see Wire Table on page 5). NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to two Class A NACs with the NACKEY (included). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 3.0 amps special application, 300mA regulated maximum per each NAC circuit Note: Maximum 24 VDC system power output is shared among all NAC circuits and 24 VDC special application auxiliary power outputs. Total available output is 7.0 amps. ADVANCED FIRE TECHNOLOGY: Sensitivity testing with printable results, on-site or off-site. Automatic drift compensation. PROGRAMMING AND SOFTWARE. Autoprogramming (learn mode) reduces installation time. Fully programmable from local keypad, local PS/2 keyboard or PC (using the standard PS-Tools Windows(@ utility). Two-level user-programmable passwords. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. USER INTERFACE: Optional plug-in 2 communicator (standard with MS- 9600UDLS(E) with USB port for local upload/download. Remote Acknowledge, Silence, Reset and Drill via addressable monitor modules, ACS Series annunciators, LCD-80F remote annunciator, or ANN-80 Series Annunciators. EIA-232 printer/PC interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjust- ments. History file with 1,000-event capacity. EIA-4851ANN-BUS supporting up to 8 ANN Series Annunciators or 32ACS Series annunciators. ElA-485 supporting up to 32 ACS annunciators. Maintenance alert warns when smoke detector dust accumula- tion is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and print- out. Point trouble identification. Local piezo sounder. Waterfiow (non-silenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and prosignal delay per point (NFPA72 compliant). Optional 4XTMF module (conventional reverse polarity/city box transmitter). Field-programming Features Off-line Programming: Create the entire program in your office using a Windows®-based software package (download PS-Tools from www.firelite.com). Upload/download system programming locally to the MS-9600LS in less than one minute. Autoprogramming: Command the MS-9600LS to program itself (takes less than 30 seconds). In the Auto-Program mode, the MS- 9600LS scans for all possible devices at all addresses, stores the device types, and addresses found, and then loads default values for all options (General Alarm). It also checks for two or more devices set to the same address. Online Editing: While still providing fire protection, the MS-9600LS/ E may be programmed from the front panel. Simple menu trees dis- played on the LCD allow the trained user to perform all functions without referring back to the programming manual. English Label Library: Quickly select labels from a standard library of more than 50 adjectives/nouns, such as "FLR 3 HALLWAY," or enter custom labels letter-by-letter. Use recall function to repeat pre- viously used label. Program Check: Automatically catch common errors, such as con- trol modules not linked to any zone or input point. Maintenance Alert The MS-9600LS(E) continuously monitors each smoke detector and is capable of reporting maintenance conditions. This reduces the risk of false alarms due to dust accumulation. Refer to the control panel installation manual for more information. Automatic Test Operation The MS-9600LS(E) performs an automatic test of each detector every two hours. Failure to meet the test limits causes an AUTO TEST FAIL trouble type. System Reset clears this trouble. Terminal Blocks AC Power - TBI: 120 VAC, 60 Hz, 3.0 amps or 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm') with 600 V insu- lation. Battery (lead acid only) - TB2: Maximum charging circuit: Normal float charge 27.6 VDC @ 1.0 amp. Maximum battery charger capac- ity: 26 AH. Minimum battery 12 AH. MS-9600LS cabinet holds maxi- mum of two 18 AH batteries. For 26 - 120 AH batteries, use the CHG-120F or CHG-75 Battery Charger and BB-55F Battery Box. NOTE: Jumper JP3, on the FACP main circuit board, must be cut to dis- able the FACP battery charger when using the CHG- 120F or CHG-75. Communication Loop - (standard) T138: 24 VDC nominal, 27.6 VDC maximum. Maximum length: 10,000 ft. (3048 m) total twisted, unshielded pair length. Maximum loop current: 400 mA (short circuit) or 100 mA (normal). Maximum loop resistance: 40 ohms. Super- vised and power-limited. Notification Appliance Circuits - TB4: Power-limited circuitry. Nominal operating voltage: 24 VDC. Current limit: fuseless, elec- tronic, power-limited circuitry. Maximum signaling current per circuit: 3.0 amps special application, 300mA regulated. End-of-Line Resis- tor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for NACs. Refer to Fire-Lite Device Compatibility Document for listed compatible devices. Page 2 of 6— DF-60334:A6 • 2120/2019 Programmable and Trouble Output Relays —TB5: Contact rating: CHG-120F: Remote battery charging system for lead-acid batteries 2.0 amps © 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive), with a rating of 25 to 120 AH. CHG-120F or CHG-75 required for Form-C relays. charging greater than 25 AH batteries. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) - T1133, Terminals 1(+) & 2(—): Maximum ripple voltage: 10 mVRMS. Up to 1.5 amps for powering four-wire smoke detectors. Power-limited circuit. Refer to Fire Lif- eDevice Compatibility Document for listed compatible devices. Nonresettable Power #1 (24 VDC Nominal) —T133, Terminals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS. Up to 1.5 amps total DC current available from each output. Power-limited circuit. TB3, Terminals 5 (+) & 6 (-): non-resettable power #2. Nonresettable Special Application Power #2 (24 VDC Nominal) - TB3, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10mVRMS. Total DC current available from each output is up to 1.5 amps. Power-limited circuit, non-supervised. ElA-485 (ACSIANN) - T136: Annunciator connector, programmable for typeANN orACS. Terminal 1 (1-) and Terminal 2 (—). EIA-485 (TERM) - T137: Terminal mode annunciator connector, Ter- minal 1 (Out +), 2 (In +), 3 (Out —), 4 (In -). EIA-232 - TB8: PC/printer connector, Terminal 1 (Transmit), 2 (Receive), 3 (DTR), 4 (Ground). Ordering Options MS-9600LS(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, single printed cir- cuit board, and cabinet. MS-9600UDLS(E): 318-point addressable Fire Alarm Control Panel, one SLC loop. Includes 2, 80-character LCD display, single printed circuit board, and cabinet. DACT-UD2: Optional communicator for remote monitoring (standard with MS-9600UDLS). SLC-2LS: Optional expander module, enables second SLC loop. 4XTMF: Optional Transmitter Module provides a supervised output for local energy municipal box transmitter, alarm and trouble reverse polarity. It includes a disable switch and disable trouble. IPDACT-2!2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (P/N: IPBRKT). Con- nects to primary and secondary DACT telephone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Sta- tion Receiver. Can use DHCP or static IP. (See data sheet DF-60407 or DF-52424 for additional information. IPBRKT: Optional mounting bracket kit consisting of screws and battery shield with standoffs required when mounting the IPDACT in lower enclosure section of FACP. IPSPLT: Optional V-Adaptor which allows connection of both panel dialer outputs to one cable input to IPDACT (sold separately). ACM-8RF: Optional plug-in relay module provides 8 Form-C 5.0 amp relays. PS-Tools: Programming software for Windows®-based PC com- puter (cable not included). Available for download at www.flre- lite.com. PRTIPK-CABLE: Cable printer/personal computer interface cable. DP-9692: Optional dress panel for MS-9600LS(E). TR-CE: Optional Trim Ring for semi-flush mounting. BB-55F: Battery box, required to house two 25 AH batteries and one CHG-120F battery charger. For batteries greater than 25 AH, consult factory for housing/mounting arrangements. BB-26: Battery backbox, holds up to two 25 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F or CHG-75 required for charging greater than 25 AH batteries. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer which uses tractor- fed paper. SElSKlT-COMMENC: Seismic kit for the MS-9600UDLS backbox. Includes battery bracket for two 7, 12, or 18 AH batteries. Compatible Addressable Devices All feature a polling LED and rota,y switches for addressing. AD3551A0365(-IV): Low-profile, intelligent, "Adapt" multi-sensor detector; B350LP base included. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. CP355: Addressable low-profile ionization smoke detector. D355PL: Photoelectric low-flow duct smoke detector, SD355R included. H3551H365: Fast-response, low-profile heat detector. H355R1H365R(-IV): Fast-response, low-profile heat detector with rate-of-rise option. H355H11H365H1(-IV): Fast-response, low-profile heat detector that activates at190° F (88° C). OSl-RI-FL: Addressable long range projected beam smoke detector designed to provide open area protection SD3551SD365(-IV): Addressable low-profile photoelectric smoke detector SD3551!SD365T(-IV): Addressable low-profile photoelectric smoke detector with thermal sensor CDRM-300: Dual relay Monitor Module CMF-300: Addressable Control Module for one Style Y/Z (Class BI A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0' (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appli- ances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM8500. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only lDCs MMF-300: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 conven- tional two-wire detectors. Requires resettable 24 VDC power. Con- suit factory for compatible smoke detectors. BG-I2LX: Addressable manual pull station with interface module mounted inside 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). DF-60334:A6 • 2(20/2019 — Page 3 of 6 EIA -232 INTERFACE PRINTER Optional REVERSE POLARITYI CITY BOX OUTPUT (4XTMF) til % 'q i. kuu 4XTMF Reverse Polarity Module T'k ,'c llI.. D °,. S 11111 sear-to IPDACT Internet Protocol DACT INTELLIGENT BEAM DETECTORS BEAM355, BEAM355S OSI-RI-FL k ° —+ lI o)J MONITORICONTROL MMF-300, MDF-300, MMF-302, CMF-300, CRF-300, 300, CDRM-300 ADDRESSABLE MULTI-MODULES MMF-300-10, MMF-302-6, CMF-300-6, CRF-300-6, ISO-6 Audio Control for ECC-501100 Emergency Command Center I I SMOKE DETECTORS SD3551T, S0365/T, CP355 BA -485 ACS/ANN-BUS ANNUNCIATORS (2-data wires, 2-power wires) 11111111 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8RF) HEAT DETECTORS H355/R, H365/R 101M] DUCT DETECTORS D355PL ANN-8O NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES porting Wireless 2 WIRELESS o GATEWAY Monitor W-GATE Module • W-MMF --°°-_ - Wireless o 10 Relay Qj Module Wireless' '- Photo Detector Wireless Pull Station W-BG12LX PULL STATION BG-12LX Page 4 of 6— DF-60334:A6 • 2/20/2019 ISO-6: Six-fault Isolator Module. Mount one or two modules in a BB- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6E SMB500: Used to mount all modules except the MMF-301 and M301 MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F W-GATE: SWIFT Wireless Gateway W-DIS-D: LCD user interface for use with the W-GATE wireless gateway and an ANN-80-W Remote Annunciator W-SD355: Intelligent, wireless photo detector W-H355R: Intelligent wireless rate of rise (135°) heat detector W-SD3551: Intelligent wireless photo/heat detector W-H355: Intelligent wireless fixed-temperature (135°) heat detector W-MMF: Intelligent wireless monitor module W-CRF: Intelligent wireless relay module W-BG1 2L)(: Intelligent wireless pullstation WAV-CRL/WAV-CWL: Intelligent wireless AV bases W-SYNC: Intelligent wireless sync module. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. Compatible Annunciators ANN-80(-W): Remote LCD annunciator that mimics the information displayed on the FACP's LCD display. Recommended wire type is unshielded. (Basic model is red; order -W version for white; see DF- 52417). ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclosure (see DF- 6024 1). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points (see DF-60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays (see DF-52431). ANN-SIPG: Serial/Parallel Printer Gateway module provides a con- nection for a Serial or Parallel printer (see DF-52429). ANN-110: I/O Driver Module provides connections to a user supplied graphic annunciator (see DF-52430). ACS-LED Zone Series: LED-type fire annunciators capable of pro- viding up to 99 software zones of annunciation. Available in incre- ments of 16 or 32 points to meet a variety of applications. ACS-LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F Annunciator: 80-character, backlit LCD-type fire annunci- ators capable of displaying English-language text. Up to 32 LCD- 80F annunciators may be connected to the ElA-485 terminal mode serial interface on the MS-9600LS(E) motherboard. NOTE: For more information on Compatible Annunciators for use with the MS-9600LS(E), see the following data sheets (document numbers) ACM-8RF (DF-51555), ACS/ACM Series (DF-52378), LDM Series (DF- 51384), LCD-80F (DF-52185). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. OF-60334:A6 • 2120/2019 - Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits.....................1 expandable to 2 Intelligent detectors .................................................159 per loop Addressable monitor/control modules .....................159 per loop Programmable software zones................................................99 ANN-BUS devices .....................................................................8 ACS Annunciators ...................................................................32 LCD Annunciators....................................................................32 Electrical Specifications Primary input power: 120 VAC, 50/60 Hz, 3.0 A. 240 VAC, 50 Hz, 1.5 A. Battery: 27.6 VDC @ 1.0 A (max). Maximum battery charger capacity: 26 AH. Minimum battery: 12 AH. MS-9600LS cabinet holds maximum of two 18 AH batteries. Communication Loop: 24 VDC nominal, supervised and power- limited. Notification Appliance Circuits: terminal block provides connec- tions for four Style Y (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 3.0 amps special applica- tion, 300mA regulated. End-of-Line Resistor: 4.7 K ohms, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Supervised and power-limited. Refer to panel documentation and Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Form-C Relays and One Fixed Trouble Form-C Relay: Contact rating: 2.0 A@ 30 VDC (resistive) 0.5A @ 30 VAC (resistive). Four-wire Resettable Special Application Power (24 VDC nomi- nal): Up to 1.5 A for powering four-wire smoke detectors. Power- Limited, non-supervised. Refer to Fire-Life Device Compatibility Document for listed com- patible devices. Non-resettable Special Application Power #1 (24VDC nominal) TB3, Terminals 3 (+) & 4 (-): Maximum ripple voltage: 10 mVRMS Total DC current available from each output is up to 1.5 A. Power-limited, non-supervised. Non-resettable Special Application Power #2 (24VDC nominal) TB3, Terminals 5 (+) & 6 (-): Maximum ripple voltage: 10 mVRMS Total DC current available from each output is up to 1.5 A. Power-limited, non-supervised. NOTE: Although each Special Application power output can deliver 1.5 A individually, the total power output from these circuits cannot exceed 1.5 A in standby. The total Alarm output for all Special Application power and NA circuits cannot exceed 7A. Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82' (42.73 cm.) wide x 0.67' (1.70 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.21' (13.23 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: 20.00" (50.80 cm) high, 22.5" (57.15 cm) wide, 8.5" (21.59 cm) deep. Weight: 27.3 lbs (12.38 kg). Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ±2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the MS-9600LS(E) and MS-9600UDLS(E) control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULC: S624 (MS-9600LSC only; see DF-60438) FM APPROVED: to ULANSI 864 CSFM: 7170-0075:217 MEA: 87-08-E IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). CBC 2007 (Seismic) NFPA Standards The MS-9600LS(E) and MS-9600UDLS(E) control panels comply with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). -AUXILIARY (Automatic, Manual and Waterfiow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterfiow) (Requires 4XTMF where DACT-UD2 is not accepted.) - PROPRIETARY (Automatic, Manual and Waterfiow). - CENTRAL STATION (Automatic, Manual and Waterfiow, and Sprinkler Supervised). - OT (Other Technologies-PSDN) For use with IPDACT. LiteSpeed°" is a trademark; and FireLite® Alarms and SWIFT® are registered trademarks of Honeywell International Inc. Windows® is a trademark of the Microsoft Corporation. ©2019 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Eli lN&MMIFP11B]Nll QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 6994105. Country of Origin: USA www.firelite.com Page of 6- DF-604:A6 . 2./20/2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0217 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models MS-9600LS and MS-9600UDLS addressable fire alarm control units. Suitable for local protective, remote, auxilIary, and central station signaling when used with appropriate optional modules and additional separate listed equipment. The panels provide one signaling line circuit for connection of up to 318 total addressable devices (159 detectors and 159 modules); two Class A or four Class B notification appliance circuits; three form C relays are provided that are default programmed for alarm, trouble, and supervisory relay outputs. The MS-9600UDLS come with the DACT-UD2 factory installed. Refer to listee's data sheet for detailed product description and operational considerations. System components: MS-9600L5, MS-9600UDLS Control Unit SLC-2LS Loop Card DACT-UD2 Digital Alarm Communicator Transmitter Modules 4XTMF Transmitter Module LDM-32F Lamp driver Module ACM-8RF Control Relay Module ANN-RLY Remote Relay ANN-80 , ANN-LED, LCD-80F Remote Annunciator ACM-16ATF, ACM-32AF Remote Annunciator AEM-1 6ATF, AEM-32AF Remote Annunciator ACC-25/50ZST Audio Command Center (Listing No. 6911-0075:207) RATING: 120 VAC, 50/60 Hz, 3.0 amps INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and FM label. APPROVAL: Listed as fire alarm control unit for use with separately listed compatible initiating and indicating devices. Also suitable for high-rise applications for use with Model ACC-25/50ZST Audio Command Center (Listing No. 6911-0075:207). *Models MS-9600LS and MS-9600UDLS panels are also suitable for high-rise application for use with Model ECC-50/100 emergency voice evacuation panel (CSFM #6911-0075:0226). Refer to manufacturer's Installation Manual for details. These control units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal as required per NFPA 72, 2002 Edition and meet the requirements of *Rev. 01 -20-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division DF-52310:A3 D-50 FCPS'24FS8(C/E) 24 Volt FlreLITeALarms 8 Amp, Remote Power Supply by Honeywell - -.-" The Fire-Lite FCPS-24FS8(CIE) is a compact, cost-effective, 8- amp remote power supplies with battery charger. The FCPS- 24FS8C/E) may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may stand-alone. Primary applications include noti- fication appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC synchronization) or auxiliary power to sup- port 24 volt system accessories. The FCPS provides regulated and • filtered 24 VDC power to four notification appliance circuits config- ured as either two Class B (Style Y) and Class A (Style Z with ZNAC-4 option module) or four class B only. Alternately, the four out- puts may be configured as any combination of resettable/non-reset- ' 1 • • • • , table power outputs (optimal for powering four-wire smoke detectors. The FCPS-24FS8(CIE) also contains a battery charger 1 • • • , 1 • e • • • capable of charging up to 18.0 Amp hour batteries. The FCPS- a • • , 1 24F58C is ULC listed , NOTE Unless the term FCPS 24FS8 this ' 1 • • • . r - otherwise specified used in a • • • • • • document refers to the FCPS-24FS8, FCPS-24FS8C, and FCPS- • , 24FS8E Features I 11$ p p a a a • • .....,t UL-Listed Notification Appliance Circuit (NAC) synchronization , , • • using System Sensor®, Wheelock®, or Gentex® "Commander2" , • appliances Operates as a "sync-follower' or as a "sync-generator" (default) - I I See note on page 2. Contains two fully isolated input/control circuits triggered from FACP NAC (NAG expander mode) or jumped permanently "ON" (stand-alone mode) Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 module) NAGs (circuits 1 & 3) 8-amp full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864) Specifications 6-amp continuous output in stand-alone mode (UL 1481) Primary (AC) Power: Compatible with coded inputs; signals passed through FCPS-24FS8/C: 120 VAC, 60 Hz, 3.2A maximum Optional power-supervision relay (EOLR-1) FCPS-24FS8E: 240 VAC, 50 Hz, 1.6A maximum In stand-alone mode, output power circuits may be configured as: Wire Size: minimum #14AWG (2.0mm2) with 600 V insulation resettable, (reset line from FACP required), non-resettable, or a mix of two and two Control Input Circuit: Fully regulated and filtered power output - optimal for powering Trigger Input Voltage: 9 to 32 VDC four-wire smoke detectors, annunciators, and other system Trigger Current: 2.0 mA (16 -32V); Per Input: 1.0 mA (9 - 16 V) peripherals requiring regulated/filtered power Trouble Contact Rating: 5 A at 24 VDC Power-limiting technology meets UL power-limiting requirements. Auxiliary Power Output: Special application power 500 mA maxi- Form-C normally-closed trouble relay mum Fully supervised power supply, battery, and NAGs Output Circuits: Selectable earth fault detection +24 VDC filtered, regulated AC trouble report selectable for immediate 2-hour delay 3.0 A maximum for any one circuit Works with virtually any UL 864 fire alarm control which utilizes Total continuous current for all outputs (stand-alone mode): an industry-standard reverse-polarity notification circuit (including 6.0 A maximum unfiltered and unregulated bell power) Requires input trigger voltage of 9 - 32 VDC Total short-term current for all outputs (NAG expander mode): 8.0 A maximum Self-contained in compact, locking cabinet - 15"H x 14.5W X Secondary Power (Battery) Charging Circuit: 2.7E/D(cm:38.1Hx3683Wx6985D) Includes integral battery charger capable of charging up to 18 AH Supports lead-acid batteries only batteries. Cabinet capable of housing 7.0 AH batteries Float-charge voltage: 27.6 VDC Battery charger may be disabled via DIP switch for applications Maximum current charge: 250 mA requiring larger batteries Maximum battery capacity: 7.0 AH Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire DF-52310:A3• 11/4/2019—Page 1of2 Applications Example 1: Expand notification appliance power an additional 8 amps. Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity acti- vation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24-volt system power up to 6 amps. Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance cir- cuits. This typically allows for mounting the FCPS at greater dis- tances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to activate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS pro- vides power to the addressable control module. *NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 10,000 feet (3,046 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24F58 can track (i.e. "follow") the strobe synchroni- zation timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24F58 is configured (via DIP switch settings) as a "sync follower," the FCPS' NAC outputs track the strobe synchroni- zation pulses present at the FCPS' sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24F58 is configured (via DIP switch settings) as a "sync generator," the FCPS' sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS' NAC outputs. In "sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24F58 complies with the following standards: NFPA 72 National Fire Alarm Code UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481 Power Supplies for Fire Alarm Systems Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2424 ULC Listed: S2424 CSFM Approved: 7315-0075:0206 MEA: 219-02E FM Approved Ordering Information FCPS-24FS8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"Wx 2.75'D [cm: 38.1H x 36.83Wx 6.985D]), and installation instructions FCPS-24FS8C: Same as FCPS-24FS8, ULC-Listed FCPS-24FS8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions ZNAC-4: Class A (Style Y) NAC option module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-11 270: Battery, 12-volt, 7.0 AH (two required) PS-I270: Battery, 12-volt, 7.0AH (two required) 90286: Optional module mounting kit, is required to install an addressable module on the power supply main circuit board Fire-Lite Alarms and System Sensorr are registered trademarks of Honeywell International, Inc. Wheelock® is a registered trademark of Cooper Technologies Company. Gentex® is a registered trademark of Gentex Corporation. 02019 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. I SO 9001 We cannot cover all specific applications or anticipate all requirements. . i MU All specifications are subject to change without notice. !NMMUMC1IfflNO - LIVALIIT STSIt For more information, contact Fire•LiteAlarms. Phone: (800)627-3473, FAX: (877) 699-4105. Country of Origin USA www.firelite.com Page 2 of 2— DF-52310:A3- 11/4/2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0075:0206 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FCPS-24FS6 and FCPS-24FS8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. NOTE: *Rev. 05-06-05JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division DF-52121:E E-325 MMF-300(A) Series, MDF-300 Addressable Monitor Modules I t1 Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" 110.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3(3.302 cm) H x 2.75' (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style 0 (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTm is a communication protocol developed by Fire-Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF-300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 — 159 on MS-9600 series panels, 01 — 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLiCATiONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special 8 AreLITeALarms by Honeywell flitpnl., MMF-300(A) (Type H) supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current 375 p (L-CU flashing) 1 com- munication every 5 sconds, 47k EOL. Maximum IDC wiling resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125(5.398cm) deep box. MMF-301(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. ° High noise (EMF/RFI) immunity. DF-52121:E •07/30/2015 - Page 1 of 4 Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems 1415 0 1 ADDRESS LOOP ) TENS ONES I o Lu 10 -.4 -J ca 0 The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3' (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65° (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. MMF-302(A) Interface Module Supports compatible two-wire smoke detectors. Page 2 of 4— DF-52121 :E • 07/30/2015 Supervises IDC wiring and connection of external power source. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATiONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATiON Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125' (5.398 cm) deep box. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4(10.16cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMBSOO surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424. ULC: S2424. FM Approved. CSFM: 7300-0075:0185. MEA: 72-01-E. Product Line Information NOTE: "A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects'/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-52121 :E • 07/30/2015 - Page 3 of 4 FireLite(5 is a registered trademark and LiteSpeed and FireWatchTM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. .. 1 We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52121:E • 07130/2015 df-60379:A1 • E-400 CRF300(A) @RrelffeALarmsr Relay Module by Honeywell ess Me Devices t 1 The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTm is a communication protocol developed by FireLite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 —99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Openishort supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identity the module to the con- trol panel, so as to differentiate between a control module and a relay module. -77 F SLCI')12 -, U (02 ) ..- Now CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SIC current draw: 6.5 MA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 VA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4 (10.16 cm) wide x 1.26" (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125 (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110VDC 0.9A Resistive Non-Coded 125 VAC 0.9 A Inductive (LIR5ms) Coded 30 VDC 0.5 A Inductive (UR2ms) Coded 30 VDC 1.0 A Inductive (PF°0.35) Non-Coded 125 VAC 0.5 A df-60379:A1 • 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA: 72-01 -E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document /56-1190-005 and refer to the SLC Wiring Manual, document 51309. LiteSpeedM is a trademark and Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. a2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. RTT -. We cannot cover all specific applications or anticipate all requirements. BIKE & MANIMMINS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-60379:A1 • 08/04109 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 'IJ114 LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson©honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models çCRF300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device' moduIe. Refer to hstee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Exceder Strobe, Horn Strobe, and Horn Notification Appliances Description E AIkT* N Powering Business Worldwide The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points. 12/24VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Technical Data TD450049EN Effective November 2016 Features Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 Audible settings 90, 95, 99 dB Industry leading-8 candela settings on 1 device Wall: 15/1575/30/75/95/110/135/185 Ceiling: 15/30/60/75/95/115/150/177 Universal mouting base Ceiling and wall Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, 3.5" octal. & 4" octal. (100mm for international customers) Universal mounting base Contact cover - 111 Common base for wall and ceiling with 5 mounting options Voltage test points for quick troubleshooting and easy spot checking (wall models only) 2 EATON www.eaton.com HN Series HS Series ST Series Environmentally friendly Low current draw Up to 9 models now in 1 appliance draw 12/24VDC on a single appliance Easy to remember model numbers Patented Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton,com/ massnotification for current installation instructions. General Notes Strobes are designed to flash at 1 flash per second minimum over their" Regulated Voltage Range All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C> and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements Synchronize using the Wheelock® Sync Modules or panels with buiItin Wheelocke Patented Sync Protocol Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage Strobes produce 1 flash per second over the "Regulated Voltage" range Compliance UL 1971, UL 464, ULC, CSFM, FM ADNNFPNANSI/OSHA RoHS IL ot It Example: l-ISWC / N N Example: HSR HN Series HIS Series ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24 VDC 124 FWR Technical Data 10450049EN Effective November 2016 12 VDC Regulated Voltage Model Range VDC 15 15/15 30 60 75 95 110 115 135 150 177 185 15 15175 ST 8.0-330 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 SIC 80330 0.061 - 0.085 0.103 0.135 0163 - 0.182 - 0.205 0,253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current® at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15175 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current® at Anechoic 95 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/15 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.230 - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current® at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15175 30 60 75 95 110 115 135 150 177 185 15 15175 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ® UL man current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the liL man current is usually at the minimum listed voltage 16 VDC for 24 VDC units), For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VOC units). For unfiltered ratings, see installation instructions. Table 3. Horn Ratings per UL Anechoic Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 Table 4. Specification & Ordering Information Model Strobe Candela Sync w/ DSM or Wheelock Power Supplies 12/24 Mounting VDC® Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UM8® HSW 15/1575/30/75/95/110/135/185 X X UMB® HSRC 15/30/60/75/95/115/150/177 X X UMB® HSWC 15/30/60/75/95/115/150/177 X X UMB® Strobes SIR 15/1575/30/75/95/110/135/185 X X UMB® STW 15/1575/30/75/95/110/135/185 X X UMB® STRC 15/30/60/75/95/115/150/177 X X UMB® STWC 15/30/60/75/95/115/150/177 X X UMB® Horn HNR X X UMB® HNW Ix X UMB® HNRC X X UMB® HNWC - X X UMB® CD 12 VDC models feature 15 & 15/75 settings CD UMB = Universal Mounting Base Model Legend HN = Horn R = Rod SIT = Strobe A = Agent Lettering (strobes only) HS = Horn Strobe AL = Alert Loitering (strobes only) C = Ceiling Mount N = No Lettering (strobes only) W = White Example 1: STIIC = Strobe, fled. Ceiling Mount Example 2: HSR = Horn Strobe, Red, Wall Mount Example 3: HSW Horn Strobe, White, Wall Mount Example 4: SIt/V-AL = Strobe, White, Wall Mount, Alert Lettering EATON www.eaton.com 3 Technical Data TD450049EN HN Series Effective November 2016 HS Series ST Series Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where multi- candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g., ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for d8A levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP).The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shalt have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM, RoHS Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.corn Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, Ni 07740 Eaton.corrmassnotification lEt 2016 Eaton ____ N All Rights Reserved Printed in USA Publication No. TD4E0049EN Powering Business Worldwide November 2016 Eaton is a registered trademark. All other trademarks are property of their respective owners. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL @ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is asynchronous and non-synchronous strobe light Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a C may be added for ceiling models and/or a'-NR' may be added for non-resettable models. For non -NR models and optional 5' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authonzed By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division