Loading...
HomeMy WebLinkAbout3193 LIONSHEAD AVE; ; FPC2021-0076; PermitPERMIT REPORT (city of Carlsbad FijieiPeijnijt Print Date: 03/17/2022 Permit No: FPC2021-0076 Job Address: 3193 LIONSHEAD AVE. CARLSBAD, CA 92010-4702 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2218801600 Track #: Applied: 05/13/2021 Valuation: $1,690,345.70 Lot #: Issued: 05/25/2021 Occupancy Group: Project #: Finaled Close Out: 11/01/2021 #01 Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: DCN -REVISED PLANS TO INSTALL NEW FIRE ALARM SYSTEM. INSTALL DUCT DETECTORS FOR FAN COIL SHUTDOWN (ADDRESSABLE, 92 DEVICES) Applicant: FPContractor: LOW VOLTAGE INTEGRATED SYSTEMS LOW VOLTAGE FIRE INC KYLE ARGUIJO 1090 JOSHUA WAY, # UNIT A 1090 JOSHUA WAY, # STE A VISTA, CA 92081-7800 VISTA, CA 92081-7800 (760) 598-4110 (760) 598-4110 FEE AMOUNT FIRE New Alarm System $1,265.00 FIRE Plan Review (per hr - Regular Office Hours) $223.50 FIRE TI Fire Alarm System (per AddI Inspection) $149.00 Total Fees: $1,637.50 Total Payments To Date: $1,637.50 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov fa2o-t- oo-ç FIRE ALARM SYSTEM SUBMITTAL Lo w%s'àItcsge I r 1 4a g r s y s 1 m s FIRE ALARM SOUNDS DATA S MEDIA S SECURITYS CCTV S ACCESS CONTROL SUBMITTAL DCN 3193 LIONSHEAD AVE. CARLSBAD, CA 92010 LOW VOLTAGE INTEGRATED SYSTEMS, INC. 1090 Joshua Way Ste A VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sd1vis.com License: CIO, C16 # 791832 PHONE: (760) 598-4110 FAX: (760) 598-4107 LowVolrage h49rated system* MATERIAL LIST PART DESCRIPTION MANUFACTURER NEW-bOX FIRE ALARM CONTROL PANEL NOTIFIER SLE-CDMA-FIRE CELL DIALER NAPCO N-ANN-80 ANNUNCIATOR NOTIFIER PC2WL HORN/STROBE @ CEILING SYSTEM SENSOR SCWL STROBE © CEILING SYSTEM SENSOR NBG-12LX PULL STATION NOTIFIER FSP-951 SMOKE DETECTOR NOTIFIER FSP- 951R SMOKE DETECTOR( INSIDE DUCT DETECTOR) NOTIFIER FMM-1 MONITOR MODULE NOTIFIER FRM-1 RELAY MODULE NOTIFIER DNR DUCT DETECTOR SYSTEM SENSOR RTS-151 REMOTE TEST SUPPLY SYSTEM SENSOR Low Voltage Integrated Systems, Inc. 1090 Joshua Way, Ste A • Vista, California 92081 FIRE • SECURITY • CCTV • ACCESS CONTROL • SOUND • MEDIA LICENSE NO. C10, C16#791832 email: info @ sdlvis.com NOTIFER by Honeywell 4 NFW-IOOX Intelligent Addressable FACP with Communicator General The FireWarden-IOOX (NFW-IOOX) is the latest intelligent address- able Fire Alarm Control Panel (FACP) within the FireWarden Series and is a direct replacement for the FireWarden-100 (NFW-100). The NFW-1 OCX comes with a pre-installed communicator and supports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the NFW-1 OCX programs just like FireWarden-100 products, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTM). Features Listed to UL Standard 864, 10th edition Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator over AlarmNet Optional CELL-MOD or CELL-CAB-N GSM Central Station Com- municator over AlarmNet® Automated activation of the NFC-50/100 Emergency Command Center NFC-FFT Firefighter Telephone option Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base compatibility Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterflow selection per module point Alarm verification selection per detector point Maintenance alert warns when smoke detector dust accumula- tion is excessive One-person audible or silent walk test with walk-test log and printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP Supoorts FlashScan® and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 198 addressable device capacity (99 addressable detectors and 99 nodules) Compatible with NOTIFIER FireWarden and ONYX Series add essable devices (refer to the FireWarden SLC Wiring Man- ual) NOTIFICATION APPLIANCE CIRCUITS (NACS) Fou- independently programmable output circuits. Circuits can be configured for the following outputs: - Style Y (Class B) - Style Z (Class A) Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability Selectable strobe synchronization per NAC 2.5 A special application, 25OmA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A DN-60959:C •7/1612018 - Page 1 of 4 PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time Custom English labels (per point) may be manually entered or selected fr&ii an internal library file Two programmable Form-C relay outputs 99 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.notifier.com. User interface LED INDICATORS Fire Alarm (red) • CO Alarm (red) AC Power (green) • Supervisory (yellow) Trouble (yellow) • Ground fault (yellow) Battery fault (yellow) • Disabled (yellow) Maintenance (yellow) • Communication (yellow) Alarm Silenced (yellow) • Fl-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge Alarm Silence Drill (Manual Evacuate) Four (4) programmable function keys • Reset (lamp test) PRODUCT LINE INFORMATION NFW-100X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display chassis with trans- former, backbox with door, plastic bag containing screws, cables, key, etc. FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.notifier.com. CELL-CAB-N/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the NFW-IOOX (red). DP-ES-B: Optional dress panel for NFW-100X (black). TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For red, order TR-CE.) BB-XP: Optional cabinet for one or two modules. Optional cabinet for up to six modules mounted on CHS-6 chassis. Battery backbox, holds up to two 25 AH batteries and CHG- 75. NFS-LBB: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-25 cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-1 20: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than I8AH. BAT Series: Batteries, see data sheet DN-6933. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS N-ANN-80: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. (Basic model is black; order -W for white; see DN-7114.) N-ANN-100R: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. (Basic model is black; order R for red.) N-ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.) N-ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-7107.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) ADDRESSABLE DEVICES FSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only. FSP-951 -IV: Addressable low-profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode. NP-200: Addressable low-profile photoelectric smoke detector. B300-6 base included, FlashScan only. NP-200-IV: Addressable low-profile photoelectric smoke detector. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951T: Addressable low-profile photoelectric smoke detector with thermal sensor. FlashScan only. FSP-951T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. FlashScan and CLIP mode. NP-200T: Addressable low-profile photoelectric smoke detector with thermal sensor. B300-6 base included. FlashScan only. NP-200T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. FSP-951R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode. NP-200R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. NP-200R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory, FlashS- can and CLIP mode. FST-951: Low-profile 135°F fixed thermal sensor. FlashScan only. FST-951-IV: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- can and CLIP mode. NH-200: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. FST-951R: Low-profile, intelligent, rate-of-rise thermal sensor. FlashScan only. FST-951 R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. FlashScan and CLIP mode. Page 2 of 4— DN-60959:C • 7/16/2018 NH-200R: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200R-IV: Low-profile 135°F fixed thermal sensor. Ivory. 13300-6- IV base inclu6ed, FlashScan and CLIP mode. FST-951H: Low-profile intelligent 190°F188°C fixed thermal sensor. FlashScan only. FST-951H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. FlashScan and CLIP mode. NH-200H: Low-profile intelligent 190°F/88°C fixed thermal sensor. B300-6 base included, FlashScan only. NH-200H-IV: Low-profile intelligent I90°F188°C fixed thermal sen- sor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. Legacy Devices FSI-851: Addressable low-profile ionization smoke detector. NI-100: Addressable low-profile ionization smoke detector. FSP-851: Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. FSP-851T: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-lOOT: Addressable low-profile photoelectric smoke detector with thermal sensor. FSP-851R: Remote test capable addressable photoelectric smoke detector for use with DNR( duct detector housing. NP-I00R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FST-851: Fast-response, low-profile heat detector. NH-1 00: Fast-response, low-profile heat detector. FST-851 R: Fast-response, low-profile heat detector with rate-of-rise option. NH-1 OOR: Fast-response, low-profile heat detector with rate-of-rise option. FST-851 H: Fast-response, low-profile heat detector that activates at 190°F188°C. NH-I OOH: Fast-response, low-profile heat detector that activates at 190°F/88°C. FAPT-851: Addressable low-profile multi-sensor detector. NP-Al 00: Addressable low-profile multi-sensor detector. B200S: Programmable, addressable sounder base. B200SR: Addressable sounder base. DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order FSP-851 R, FSP-951 R, or NP-1 OOR separately.) DNRW: InnovairFlex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order FSP-851R, FSP-951R, or NP-1 OOR separately.) Addressable Modules FMM-I: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-I00: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. FDM-I: Dual Monitor Module. Same as NMM-I00 except it provides two Style B (Class B) only IDCs. NDM-I00: Dual Monitor Module. Same as NMM-100 except it pro- vides two Style B (Class B) only lDCs. FMM-101: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NMM-I00P: Miniature version of NMM-I00. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. FZM-I: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. NZM-I 00: Similar to NMM-I 00. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. FCM-I: Addressable Control Module for one Style YIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NC-I00: Addressable Control Module for one Style YIZ (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. FIRMA: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. NC-I OOR: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SM13500. NBG-I2LX: Addressable manual pull station with interface module mounted inside. NOT-BGI2LX: Addressable manual pull station with interface mod- ule mounted inside. ISO-X: Fault Isolator Module. NI 00-ISO: Fault Isolator Module. ISO-6: Six-fault isolator module. Mount one or two modules in a BB- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SM13500: Used to mount all modules except the FMM-I01/NMM- 1oop. NMM-I 00-I 0: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NZM-I00-6: Six-zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SWIFT Wireless Devices FWSG: Wireless Gateway FWD-200P: intelligent, wireless photo detector. FWH-200R0R135: LiteSpeed intelligent wireless rate of rise (135°) heat detector. FWD-200ACCLIMATE: Wireless Acclimate Detector FWH-200F1X135: intelligent wireless fixed-temperature (135°) heat detector. FW-MM: Intelligent wireless monitor module. FW-RM: Intelligent wireless relay module. NBG-I 2LW: Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: lntelligentAV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden-IOOX, see the following data sheets (document numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), NIOO-lSO (DN-6994), NP-100 series (DN-6995), NH-100/NH-I0OR (DN- 6997), DNR/InnovairFlex (DN-60424, DN-60429), NP-A100 (DN-6998), NMM-100/NMM-IOOP/NDM-10017VZM-100 (DN-6999), NC-100 (DN- 7000), NC-100R (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-1/ FZM-1/FMM-101 (DN-6720), FCM-1/FRM-1 (DN-6724), NOT-BG12LX (DN-7001), NBG-I2LX (DN-6726), and Fire Wa rden SLC Manual (52304). DN-60959:C • 7/16/2018 - Page 3 of 4 SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits................................................1 Addressable device capacity..................................................198 Programmable software zones.................................................99 Annunciators.............................................................................16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (FireWarden-100X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, % watt (PIN 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kQ - 22 kQ ELR range. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CEIB): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0— 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Addressable Device Accessories End-of-Line Resistor Assembly (R-47K and R-3.91K): The 47k ohm assembly supervises the NMM-100-10, NDM-100, NMM- lOOP, and NC-1 00 module circuits. The 3.9k ohm assembly super- vises the NZM-1 00-6 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. NFPA Standards The FireWarden-100X complies with the following NFPA 72 Fire Alarm Systems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet-switched Data Net- work) — IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). — CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 CSFM: 7165-0028:0505 FDNY: COA#6268 ISO 9001 .ap• 1 11Z! ®dII I Mu,mIJr quiluy sysruuqu This document is not intended lobe used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. AlanmNet®, NOTIFIER®, FireR®rder®, SWIFT®, and System Sensor® NOTIFIER are registered trademarks of Honeywell International Inc. Microsoft® and 12 Clintonville Road Windows® one registered trademarks of the Microsoft Corporation. ® NOTIFIER Northford, CT 06472 ©2018 by Honeywell International Inc. All nights reserved. Unauthorized use of this document is strictly prohibited. () 203.484.7161 by Honeywell www.notifier.com Country of Origin: USA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM t§ LISTING No. 7165-0028:0505 Page 1 of 2 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneyweIl.com DESIGN: Models FireWarden-50X (NFW-50X) and FireWarden-100X *(NFW IOOX) Fire Alarm Control Units. Automatic, manual, waterfowl, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The FireWarden-50X (NFW-50X) is a compact version of the FireWarden-100X *(NFW100X) The FireWarden-50X (NFW-50X) has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The FireWarden-100X *(NFW IOOX) has 198 addressable device capability and 4 Notification Appliance Circuits with 3.oamps total 24VDC output in Alarm expandable to 6.oamps with Model PWRMOD24. The Model IPOTS-COM provides Phone and IP communication. Models FireWarden-50X (NFW-50X) and FireWarden-IOOX *(NFw100X) system components are as follows: IPOTS-COM POTS and IP Communicator 4XTMF Transmitter Module N-ANN-80 Remote Annunciator Module ANN-100 Remote Annunciator Module N-ANN-I/O LED Driver Module N-ANN-S/PG Serial/Parallel Interface Module N-ANN-RLY Form-C Relay Module N-ANN-LED Annunciator Module N-ANN-RLED Annunciator Module CELL-MOD GSM Communicator DP-ES-R Dress Panel Model FireWarden-100X *(NFW IOOX) system components are as follows: PWRMOD24 NAC Power Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. RATING: 120/240Vac 50/60Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. *Rev 09-03-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7165-0028:0505 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. XLF: 7165-0075:0500 Rev 09-03-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division StarLink- Commercial Fire Alarm Communicators: COMMERCIAL FIRE Sole & Dual Path Cellular &/or IP Universal full event sole path cellular & dual path UL and NFPA 72 Fire Code-Compliant, the StarLink Series cellular &/or IP commercial fire alarm reporting from Wireless Commercial Fire Alarm Sole Path & Dual Path any panel brand, virtually anywhere Communicators provide universal support for any brand 12V to 24V fire alarm control panel, reporting in Contact ID and 4/2. For use as primary or backup communications on all With broadest coverage footprint available in Verizon Network 12V-24V control panels and FACPs that communicate Certified TMCDMA or GSM 3/4G models on the AT&T. network, as well as mercantile models, all::provide the most economical using Contact ID and 4/2 (such as on legacy panels) solution and for easy, versatile installation. Reports to aty Central Station nationwide, with your Safeguard Accounts & Reliablflty For applications currently choice of cellular networks: Verizon Network Certified relying upon quickly-disappearing traditional phone lines, cDMA or GSM 3/413 on AT&T . .. . StarLink wireless communicators can be used for primary or - . . . . backup communications, and will not only safeguard the fire . .. Easy, flexible installation, activation & online account alarm reporting transmissions for the future, but provide the - management end-user monthly savings for each costly FACP-dedicated Cost-saving models and plans for any code landline they replace. And, for upgrading older wireless fire alarm communicators on 2G and other phased-out cellular networks, all requirement. Substantial savings over monthly dedicated StarLink Fire radios, offer a $100 tradeup incentive to help defray landline charges. And, $100 saving incentive with any 2G the cost of the hardware replacement to the advanced state-of- Communicator upgrade (unlimited). the-art StarLink model of choice. - . Flexible Performance & Reporting Options. StarLink Fire r provides full data reporting, in sole and dual path, as a primary or backup, to any central station of your choice, without requiring I U+.- 4-A k1 any spucOI CLfUIfrIJI ICI IL on frIlCi l,'OCO. 'JILOOlILJlACtJIC ..flfll ID = . are available to meet various codes and requirements, with supervisory check-ins from 200 seconds, to 5-minutes, to an hour. The units are very easily activated, plans and options are selected, and 24/7 account management is provided all through www. napcocomnet.com. And, StarLink Fire Communicators are easily / standardly operating between 12V and 24V. Flexible in connected to any panel or Fire Alarm Control Panel (FACP) \, any application, StarLink Fire also comes in standard, or Mercantile Models in metal housings, with code- compliant supervision, with or without using conduit; and choice of power options, powered by the panel or using its own 120V Power Supply. c ,xje-cori p!ienr standard or rrercannle metal models (right and left, respectreely). Napco StarLink3 Universal Fire Alarm Communicators . Sole Path Cellular and Dual Path Cellular &/or IP • Money-saving 2G Tradeup incentive credit Models Bonus: Full High-Speed Napco Panel remote Choice of plans (varies by model) - check-ins from 200 seconds, to 5-minutes to 1 hour, Verizon or AT&T uploading! downloading Patented Signal BOOStTM signal amplification circuit • COMPUANCES: NFPA72 Editions: 2013, 2010 2007; UL 864, 9th Ed., UL1 610, UL985, UL1 023, and high-gain performance antenna for longer range NYFD (as back-up); CSFM and reliability nationwide (No Zia IN NETWORK .. veripj CERTIFIED fi1I - .- - - - - -.--- 1 FTr / 7 , / 1 /1 L $Lk Fire Specifications - Ordering Information TANDARD MODELS; COMMERCIAL FIRE SOLE PATHCELLULAR & Durable ABS plastic hosing includes three keyhole slots for DUAL PATH CELLULAR &/OR IP ("I" MODELS)* rrcuiting (for comrrercial application, aligns with triple gang SLE-CDMA-FIRE Standard ABS (Red) Fire Sole Path Alarm b.tes,) Co-nmunicator, Cellular CDMA, Verizon-Network Certified Dimensions: 53/8">c77/8"x 1-7/8" (HXWXD) SLE-CDMAJ-FIRE as above, Dual Path Alarm Communicator, Weight: 13.5 oz Celular &/or IP (primary or backup, selectabla) 3 LED Indicators - Gen, Signal Strength; Amber- Busy! SLECDMA-CFB-PS Commercial Fire Mercante model in red tivation; Red-Trouble metal housing, COMA, Verizon-Network Certified. Direct 1 2OVAC Pa:ented Signal BocstTM signal amplification circuit and high- Pcwered (w/ provisions for backup battery/charger). Or, Optional n performance antenna TRF20 plug-in transformer may be used, where codes permit Operating Environrrerit: 0 to 490 C (32-1200F), up to 93% SLECDMA-CFB Commercial Fire Mercantile model in red metal h..,ridfty (non-condensing) hcusing on CDMA, Verizon-Network Certified Powered directly 12'/ - 24V UniversaFACP Support, auto-current sensing. fron control panel Stort all brands communicating in Contact ID and 4/2 Note: Substitute prefix "SLE3I4G-" on any models above for Fevered by anel, Low current draw, 71mA standby, 200mA AT&T 3/4G Network tcn-umlt ACCESSORIES: MERCANTILE MODELS Isimilarto above SLE-DLEX Optional, as above, for downloadirg, extends distance Locking Metal Enckisurewith Hinged cloor& 2 key-slots for wall to Napco panel up to 100' nounting (LED indicat-,rs, inside). TRF20 Optional Plug in AC Transformer, 16.5V/ 20VA (use is subject Dimensions- 9-5/8"x 11-3/4" x3-3/8"D (HxWxD) to l-Dcal code compliance) 'ght: 8 lbs (max. power supply models) SLE-DLCBL Optional High-Speed Napco Panel Jp/download cable EIctrIcalRatIngs for 120VAC,60Hz . ___ ii For Models with Power Supply: Available: StarLink Intrusion Radios in lnputVoltage: 10VAC Nominal . . standard and mercantile versions -c Input Currant: 400rrA maximum . . - 51 F GSM-3/$G Standard Burglary It tMaximumsCharging Current: 200mA I Radio (Black, GSM 3!4G on AT&T Electrical Ratings f3r+12V Network powered by panel. SLE-CDMAaabovo, but COMA For Models withoLt Power Supply:. - - communicatena, Verizon.Network - - . - fBirtput Voltage: '1 -15VDC (power-limited output from listed Certified. - control panel) SLECDMA-C3 Commercial Burglary CDMA RadiaVerizonCertdled, in . - - - Input Current: 71mA with peak RF transmission current of ') white metal ttousing. Powered directly - from contropanel+ !ectrical Ratings for the IN I Burg/Fire Input: l SfE3/4G-05 as above, but GSM 3/4G on AT&T Network, = - Input Voltage: 9-15'/DC - St SLE3/46-C9 Burglary -TF Commercial Burgla - - ' MaximurninputCurrent: Up to 2mA from FACP NAC circuit -' COMA, Vardon Certified in white metal ¶ Electrical Ratings for IN 2 and IN 3: housing with power supply powered by plug-in tt.5V / 20VA transformer & I Maximum Loop Voltage: 15VDC - —•. provision fobattery Maximurr Loop Current: 1.2mA Electrical Ratings or 3 PGM Outputs: - Open Colector Outputs: Maximum voltage 3V when active; O NAPCD . :. - 5V maximum whei not active Maximum PGM Sink Current:50mA mount. 333 Bayview Ave., Amityville, NY 11701 USA ' - 1-800-645-9445 • Fax: 1-631-789-9292 Operating Environment 0 to 49° C (32-120°F), up to 93% www.napcosecUrity.com humidity (non-condensing)- . - 12V - 24V Lniverszl FACP Support, auto-current sensing. . . . [) \_- NETWORK Su3port all brands communicating in Contact ID and 4/2. - - N FpX VnZ2!' CERTIFIEO COMPLtAPCES: NFPA 72 Editions: 2013,2010, 2007; UL 864, 9€n Ed., UL1 610, UL985, UL1023; NVFD (as back-up); CSFM *s5arjrkAre are -also rated to support intrusion/Burglary alarm reports where applicable. StarLlrrk" and Signal Boost are trademarks of NAPCO. Pats Pending. spucficatiorrs subject to change. - ©NAPCO 4APCO SmurityTchreleg1e 'JASDAONSSC) A67602016.5 Ver Bar ar, VerlsomnNetwod Certrfled. 14 T&Ted other tradercwks are tr dmarks of thee respemve companes uuaffilwtødwr-t NPO CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0992:0144 Page 1 of 2 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Napco333 Bayview Avene, Amityville, NY 11701 Contact: David Wagner (631) 842-9400 Fax (631) 842-2726 Email: dwagnernapcosecurity.com DESIGN: Models SLE3/4G-CB, SLE3/40-CB-TF, SLE3/4G-CFB, SLE3/4G-CFB-PS, SLE-CDMA, I SLE-CDMA-FlREJ SLE-GSM-314G, SLE-GSM-FIRE, SLECDMA-CB, SLECDMA-CB-TF, SLECDMA-CFB, SLECDMA-CFB-PS, SLE-LTEV-FIRE, SLE-LTEV-8D, SLE-LTEV, SLE-LTEV-CFB-PS, SLE-LTEV-CB-TF, SLE-LTEV-CFB, SLE-LTEV-CB, SLE-LTEA-CFB, SLE-LTEA-CFB-PS and SLE-LTEA-FIRE Sole Path Communicators. Model numbers may be followed by an alpha/numeric suffix for marketing purposes. Models SLECDMAI-CFB-PS, SLE3/4G1-CFB-PS, SLECDMAI-CB-TF, SLE3/4Gl-CB-TF, SLECDMAI-CFB, SLE3/4G1-CFB, SLECDMAI-CB, SLE3/4Gl-CB, SLE-GSMI-3/4G, SLE-CDMAI, SLE-GSMI-FIRE, SLE-CDMAI-FIRE, SLE-LTEVI-CFBPS, SLE-LTEVI-CFB, SLE-LTEVI-FIRE, SLE-LTEAI-CFBPS, SLE-LTEAI-CFB, SLE-LTEAI-FIRE, *SLEFNICFB..PS *SLEFNlCFB, and *SLE..FNI..FIRE Dual Path Communicators. Model numbers may be followed by an alpha/numeric suffix for marketing purposes. *Dual Path Communicators can also be utilized as a Sole Path Communicator. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 Vac - SLE3/40-CB, SLE3/4Gl-CB-TF, SLE3/4G-CFB-PS, 5LE314G1-CFB-PS, SLECDMA-CFB-PS, SLECDMAI-CFB-PS, SLECDMA-CB-TF, SLECDMAI-CB-TF, SLE-LTEV-CFB-PS, SLE-LTEV-CB-TF, SLE-LTEVI-CFBPS, SLE-LTEA-CFB-PS, SLE-LTEAI-CFBPS, *SLEFNICFBPS 10-15 Vdc - SLECDMAI-CB, SLE3/4G1-CB, SLE-GSMl-3/4G, SLE-CDMAI, SLE-LTEV, SLE-LTEV-8D, SLE-LTEV-CB 10-25 Vdc - SLECDMAI-CFB, SLE3/4G1-CFB, SLE-GSMl-FIRE, SLE-CDMAI-FIRE, SLE-LTEV-FIRE, SLE-LTEV-CFB, SLE-LTEVI-FIRE, SLE-LTEA-CFB, SLE-LTEA-FIRE, SLE-LTEAI-FIRE, SLE-LTEAI-CFB, SLE-LTEVI-CFB, *SLEFNICFB *SLEFNIFIRE 11-15 Vdc - SLE3/4G-CB, SLE-CDMA, SLE-GSM-3/4G, SLECDMA-CB 11-25 Vdc - SLE3/4G-CFB, SLECDMA-CFB, SLE-CDMA-FIRE, SLE-GSM-FIRE *Revision 2-8-21 VMN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7300-0992:0144 Page 2 of 2 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, L and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Revision 2-8-21 VWN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division NOTgFER® by Honeywell N-ANN-80 80-Character Serial LCD Annunciator General The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The N-ANN- 80 and the FACP communicate over a two-wire serial interface employing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The N-ANN-80 is black; for white order N-ANN-80-W. The N-ANN-SO displays English-language text of system point infor- mation including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels pro- grammed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-80s may be connected to the ANN-Bus of each FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTI- FIER FACPs with an ANN-Bus, such as the NFW-50X. Features Listed to UL Standard 864, 9th Edition Backlit 80-character LCD display (20 characters x 4 lines) Mimics all display information from the host panel Control switches for System Acknowledge, Signal Silence, Drill, and Reset Control switches can be independently enabled or disabled at the FACP Keyswitch enables/disables control switches and mechanically locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP Enclosure supervised for tamper System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence Local sounder can be enabled or disabled at the FACP N-ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels Time-and date display field Surface mount directly to wall or to single, double, or 4" square electrical box Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80K1T for angled view mounting Can be remotely located up to 6,000 feet (1,800 m) from the panel Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC) Up to eight N-ANN-80s can be connected on the ANN-Bus Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum Ambient temperature: 32°F to 120°F (0°C to 49°C) Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F) 5.375" (13.65 cm.) high x 6.87E" (17.46 cm.) wide x 1.375" (3.49 cm.) deep For use indoors in a dry location All connections are power-limited and supervised The ANN-Bus POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- IARY POWER SUPPLY The ANN-Bus can be powered by an auxiliary power supply when the maximum number of ANN-Bus devices exceeds the ANN-Bus power requirements. See the FACP manual for more information. ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The N-ANN-80 connects to the FACP ANN-Bus communications cir- cuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total wors: case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. DN-7114:D•3/15/2018—Page 1of2 NOTE: For total worst case current draw on a single ANN-Bus refer to appropriate FACP manual. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power circuit is acceptable. All connections are power-limited and supervised. A maximum of eight N-ANN-80 modules may be connected to this circuit. Ordering Options: N-ANN-80: Black 80 character LCD Annunciator. N-ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-B: Black surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. Agency Listings and Approvals The listings and approvals below apply to the N-ANN-80. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult factory for latest listing status. LJL: S635 FM approved CSFM: 7120-0028:0240 MEA: 442-06-E Vol. 2 Iso 9001 -_s.q.l :b ff!J & MMUC1I QUIEITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to.date and accurate. We cannot cover all specific applications or anticipate all requirements. NOTI Fl ER All specifications are subject to change without notice. 12 Clintonville Road NOTIFIER® is a registered trademark of Honeywell International Inc. Northford, CT 06472 flY2018 by Honeywell International Inc. All rights reserved. Unauthorized 203.484.7161 155 of this document is strictly prohibited. www.notifier.com Country of Origin: USA NOTIFER® by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION MOM OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. I 7120-0028:0240 I Page 1 of I CATEGORY: 7120-- ANNUNCIATORS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: ModelslN-ANN-80 land *N ANN 80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. XLF: 7120-0075:0211 *Rev 12-11-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed !\ the, test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division SYS.TE. 5EAL:øi1 Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Aciencv Listinas SIGNAUNG Ik LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 AVDS868-02 • 12/01/2007 • Page 3 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the SyncoCircUitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2,5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02 • 12/01/2017 • Page 2 UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 DC Input 8-17.5 Volts 15cd 30cd lip 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 1115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 285 Non-Temportal Low 78 101 151 172 199 229 262 3.lKTemporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data l' 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3,1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 2.47'(62.7 mm) 1.37" (34.8 mm) 6.83di' (173 FT 6.92" liam (175. L-Series Dimensions A0545-OO A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box -01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box _ Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White L-Series Ordering Information Iriir.OB Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". 4'S7EIY1 3825 Ohio Avenue • St. Charles, IL 60174 52017 System Sensor. Product spec I cat ann subject to change without notice. Visit oystemsensor.com Phone: 800-SENSOR2 • Fax 630-377-6495 lorcurrent product inlormatiorr, including thelatestversion of Odsdalasheet. AVDS868-02 • 1210112017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17135-1653:0503 I Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *4\ Wall Horn Strobes; PC2RL,I PC2WLj *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walllrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. I 7125-1653:0504 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL,I SCWLIand SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr selling: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division I.. PUSH I4 IPuuoM DN-6726:D • H-240 NBG-12LX Addressable Manual Pull Station The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on CLIP protocol loops. Up to 159 NBG-1 2LX stations per loop on FlashScan® pro- tocol loops. Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.60z. (272.15g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location NOTIFIER y Honeywell The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4" (10.16 cm) square electrical outlet box, or will sunace mount to the model SB-- 0 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4' (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, the-i pulling down on the handle causes it to latch in the down/ac1vated position. Once latched, :he word "ACTI- VATED" (in br'ght yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door aLomatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 —159 on FlashScan® systems, 1 —99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Arm Stations shall be non-cooed, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to ormal except by use of a key. An operated sta- tion shall autcmatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored poIcarbonate material with clearlj visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-i 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or DN-67260 • 4/13'2O12 -Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-1 2LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. CSFM: 7150-0028:0199. FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). BSMI: C1313066760047. U.S. Coast Guard. Lloyd's Register. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 IN-1:11212113M MCINER11111 & MNUMCTURING QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. Page 2 of 2— DN-6726:13 • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 1f77 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17150.0028:0199 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-12-LO,_NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-I2WP, NBG-12LWP, NBG-12L,INBG-12LXI NBG-I2LA, NBG-12P5, NBG-I2LSP, NBG-I2LPS, NBG-12LPSP, NBG-125P, NOT-BGI2LX, NBG-I2LXSP, NBG-12LXBL and NBG-I2LXP fire alarm pull boxes. All units except Model NBG-125 are dual action pull stations. Models NBG-12LR and NBG-I2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-1 2WP, NBG-1 2LW, NBG-1 2W, NBG-I2LWP, NBG-1 2LAO, NBG-12LO, NBG-12LAOB and NBG-I2LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 5lbs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division NOTIFI ER CR) by Honeywell FSP-951 Series Addressable Photoelectric Smoke Detectors The NOTIFIER® FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the FSP-851 Series. A new modern, sleek, con- temporary design and enhanced optical sensing chamber is engi- neered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T. The FSP-951R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan® and CLIP applications as designated. Features SLC LOOP: Two-wire SLC loop connection Unit uses base for wiring Compatible with FlashScan® and CLIP protocol systems Stable communication technique with noise immunity ADDRESSING: Addressable by device Rotary, decimal addressing (Refer to the NOTIFIER panel manuals for device capacity.) ARCHITECTURE: Sleek, low-profile, stylish design Unique single-source design to respond quickly and dependably to a broad range of fires Integral communications and built-in device-type identification Built-in tamper resistant feature Remote test feature from the panel Walk test with address display (an address on 121 will blink the detector LED: 12-[ pause]-1 (FlashS can systems only) Built-in functional test switch activated by external magnet Removable cover and insect-resistant screen for simple field cleaning Expanded color options OPERATION: Designed to meet UL 268 7th Edition Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. Low standby current MECHANICALS: Sealed against back pressure SEMS screws for wiring of the separate base Designed for direct-surface or electrical-box mounting Plugs into separate base for ease of installation and maintenance Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: Optional relay, isolator, and sounder bases Installation FSP-951 Series plug-in intelligent smoke detectors use a detach- able base to simplify installation, service and maintenance. Installa- tion instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring only. When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and iso- lator bases. Construction These detectors are constructed of fire-resistant plastic. The FSP- 951 Series plug-in intelligent smoke detectors are designed to com- mercial standards and offer an attractive appearance. Operation Each FSP-951 Series detector uses one of the panel's addresses (total limit is panel dependent) on the NOTIFIER Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The FSP-951 Series offers fea- tures and performance that represent the latest in smoke detector technology. DN-60977:B • 7/1/2019 -Pagel of 3 Product Line Information NOTE: "-IV' suffix indicates CLIP and FlashScan device. FSF-951: White, low-profile intelligent photoelectric sensor, FlashS- can only FSP-951A: Same as FSP-951 but with ULC listing FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor FSP-951A-IV: Same as FSP-9514V but with ULC listing FSP-9511: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device, FlashScan only FSP-951TA: Same as FSP-951T but with ULC listing FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F \ (57°C) fixed-temperature thermal device FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing FSP-951R: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, FlashScan only FSP-951RA: Same as FSP-951R but with ULC listing, for use with DNRA FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable, for use with DNRJDNRW FSP-951 RA-IV: Same as FSP-951 R-IV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. B300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. ULIULC listed (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224B1-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224B1-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224B1A-WH: White, isolator detector base, ULC listing B224B1A-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing Page 2 of 3— DN-60977:B • 7/1/2019 B200SA-IV: Same as B200S-IV, ULC listing B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B2IOLP(A) base TR300-IV: Ivory, replacement flange for B2IOLP(A) base RAIOOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack SPECIFICATIONS Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0 (5.3 cm) high; base determines diameter - B300-6: 6.1(15.6cm) diameter - B501: 4(10.2cm) diameter For a complete list of detector bases see DN-60981 Shipping weight: 3.4 oz. (95 g) Operating temperature range: FSP-951: 32°F to 122°F (0°C to 50°C) FSP-951T Series: 32°F to 100°F(o°C to 38°C) FSP-951R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C) UUULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 mlmin.), suitable for installation in ducts Relative humidity: 10% - 93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA © 24 VDC ("ON") DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. Listings and Approvals Listings and approvals below apply to the FSP-951 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listing: S1115 FM Approved CSFM: 7272-0028:0503 NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com Iso 9001 flIrIf &MVIF11I QUILITY SYSrEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot coven all specific applications or anticipate all requirements. All specifications are subject to change without notico. FisvvScodqDilFlERs. and System Sc sonTore z vgivnor&i trafvmorns cfHcnoycell lnnvrrut:onul, 41C. S2yt9 ho Honeywell Inierootionol inc. All rignis rosen'ed lJnulnonzed use of his document is strictly prohutted. Country of Origin: Mexico NOTIFIER® by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0503 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FSP-951, FSP-951R, FSP-951T, FSP-951T-ISO, NP-200, NP-200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-951T, FSP-951T-ISO and NP-200T have complementary heat detectors. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: *Model B71OLP (CSFM No. 7300-0028:0173); System Sensor Models *13224131, *B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:0238); *13501 *B2IOLP B300-6, B300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW(CSFM No. 3240-1653:0209) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. *All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Revision 12/16/19 DCC This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v" operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division DN-6720:E [FMM.1(A FMM.101(A), FZM-1 (A) & FDM-1 (A) NOTlFIER® Monitor Modules with FlashScan® by Honeywell General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM1(A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3' (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM.1 (A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- 1o 7 E) qjj c ç) FMM.1(A) (Type H) open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DNJ-6720:E • 07/3012015 - Page 1 of 4 FMM.1 01(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01-99 on CLIP loops. 1415 0 1 ADDRESS 0 1 12 3 LOOP j 10 5 71 I9 8 6 9976 I TENS ONES I— o Lu 0 cc The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on FlashScan loops, 01 - 99 on CLIP loops. LED flashes during normal operation; this is a program- mable option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Page 2 of 4— DN-6720:E • 07/3012015 Humidity range: 10% to 93% noncondensing. Agency Listings and Approvals Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x In some cases, certain modules may not be listed by certain .25"(3.175 cm) deep. Mounts to a 4" (10.16 cm) square x approval agencies, or listing may be in process. Consult fac- 2.125" (5.398 cm) deep box. tory for latest listing status. FDM.1(A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1 (A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. JL CAUTION: Avoid duplicating addresses on the system. UL: S635. ULC: S635. FM Approved. CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. MEA: 457-99-E. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). Fire Dept. of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-1 01(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4(10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMBSOO surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. ON-6720:E • 07/30/2015 - Page 3 of 4 FlashScan® and NOTIFIER® are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 I U & MMIF*C1URIN QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6720:E • 07/30/2015 DN-6724:B3 FCM-1(A) &FRM-1(A) Series @ NOTIFIER 8 Control and Relay Modules by Honeywell - General FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1 (A) Relay Module: The FRM-1 (A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1(A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScan@ releasing applications. Construction The faceplate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01 -159). FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1 (A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a .SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On ccmmand, it activates its internal relay. The FCM-1 (A) super/ises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power Eupply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply wit never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM.1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3.17/2O11—Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and Til): Maximum (NAC): Regulated 24 VDC; Maximum (Speaf.cers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM.1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C) Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM.1 (A) Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5A 30 VDC Inductive Coded (L/R=5ms) 1 A 30 VDC Inductive Coded (L/R=2m5) .3A 125 VAC Inductive (PF=0.35) Non-Coded Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1(A): Intelligent Addressable Control Module. FRM-1(A): Intelligent Addressable Relay Module. A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1 (A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. Notifier@ and FlashScan® are registered trademarks of Honeywell International Inc. 02011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. :b U U We cannot cover all specific applications or anticipate all requirements. ENSINESINS I 1111111111FACTION All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2- DN-6724:B3 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17300-0028:02191 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XPIO-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1 FRM-1 ontrol modules, and *FDRM.1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division * -_\ SYSTEM SE1Is° Intelligent Non-Relay Photoelectric Duct Smoke Detector The /nnovairFIex Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between. Features Photoelectric, integrated low-flow technology (detector head sold separately) Air velocity rating from 100 fit/min to 4,000 ft/mm Adjusts to square and rectangular mounting configurations Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented tool-free, plug-in sampling tubes New cover tamper signal Increased wiring space with a new 3/4-inch conduit knockout Housing has space for mounting a relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection UL 268A listed Remote testing capability Requires com line power only NEMA Type 4 UL listed for non-hazardous indoor and outdoor applications (DNRW only) UV-resistant, UL-listed housing and cover material (DNRW only) Agency Listings ® MSFM LISTED APPROVEO approved 2911 3029700 3242-0053:200/210 2125 The InnovairFIex Series DNR and DNRW are intelligent (addressable) non-relay photoelectric duct smoke detectors. Like all InnovairFIex detectors, the DNR and DNRW both feature an adjustable housing design that fits square and rectangular installation footprints, mounts to both round and rectangular ductwork, and utilizes tool-free, plug-in sampling tubes for increased application flexibility and installation ease. These units sense smoke in challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). For even more extreme environments like rooftops, the DNRW's NEMA 4-rated watertight and UV-resistant housing protects against windblown dirt and dust, rain, and hose directed water, enabling it to be installed without a costly enclosure, saving time and money. The InnovairFIex housing cover isolates the sensor head from the low-flow feature for simple maintenance, and a cover tamper feature initiates a trouble signal for a removed or improperly installed sensor cover.The housing also provides a 1/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module to meet specific application requirements. These detectors can be customized to meet local codes and specifications without additional wiring. The InnovairFIex line is compatible with all previous Innovair models, including remote test accessories, for easy retrofits. WARNING: Duct smoke detectors have specific limitations. InnovairFiex Duct Smoke Detector Specifications The air duct smoke detector shall be a System Sensor lnnovairFlex°° DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA 4 Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velocities of 100ft/min to 4000 ft/mm (0.5 rn/sec to 20.32 rn/sec).The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS1 51 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. _ Size: (Rectangular) 14.38 in (37 cm) Length; Sin (12.7 cm) Width; 2.5 in (6.6 cm) Depth (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA 4 (DNRW only) Operating Temperature Range: -4°F to 158°F (-20°C to 70°C) Storage Temperature Range: -22°F to 158°F (-30°C to 70° C) Operating Humidity Range: 0% to 95% relative humidity (non-condensing) Air Duct Velocity: 100 to 4,000 It/mm (0.5 to 20.32 m/s) DCOIL (if included): 17.5- 26.4 VDC, 95 mA max - -I] Please see detector head installatior ndnll 1 fo lrrr.il .pririnr II ..ipZ - 1 Device Standby Alarm RA100Z OmA 12mAMax. RTS1S1/RTSIS1KEY 0 m 12rnAMax. Installing the InnovairFiex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector.The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). AOS-0422-005 I — — — — —' Wiring for Intelligent Non-Relay Duct Smoke Detector Syteh *irhg diagram for DNR: I I I ----- UL/FM LISTED 1ST CONTROL DETECTOR PANEL IN LOOP DNR to RA100Z: +RA4 (+) _1 2ND DETECTOR IN LOOP RA100Z REMOTE ALARM LED OPTION 1 PER UNIT DNR to RTS1 51/RTS151 KEY DNR to RTS1 51/RTS151 KEY with DCOIL Option*: with 'R" Remote Test Capable Detector Head Option: TEST COIL + TEST COIL + TESTCOIL — RTS151/RTS151KEY NAL TESTCOIL— —ctNPowEj----- fl5 COMM+ - COMM+ OUT (CONV ONLY) + OUT (CONV ONLY) + . 2 : ATS151/RTS151KEY - RNRTS— CommCOMM—F-5 3 :JUMPER RNRTS — REMOTETESTSTATION RA+ e4 RA+ LED OPTION 1 PER UNIT RTS+ RTS+ TEST COIL OPTION 1 PER UNIT 95 mA CURRENT DRAW "Important Notes The use of either the RTS1 51 or RTS1 51 KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the DNR or DNRW installation manual for more information. - The RTS1 51/RTS15 1 KEY test coil circuit requires an external 24 VDC power supply which must be UL listed. AO-O42.005 Accessories Ssten en,or provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. r: Liii RTS151 UL S2522 RTS1 51 KEY UL S2522 RA100Z UL S2522 Ordering Information Iu -, __J DNR Intelligent non-relay photoelectric low-flow duct smoke detector DNRW Watertight intelligent non-relay photoelectric low-flow duct smoke detector Accessories DCOIL Remote test coil required with ETX Metal exhaust tube duct width 1 ft (03 m) RTS451/RTS451KEY/RTS151/RTS151 KEY DST1 Metal sampling tube duct width up to ift (0.3m) DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (03 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 12 m) DSTS Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) DST1 0 Metal sampling tube duct widths 8 f to 12 ft (2.4 to 3.7 m) P48-21-00 End cap for metal sampling tubes M02-04-00 Test magnet RA1 OOZ Remote annunciator alarm LED RTS151 Remote test station RTS151 KEY Remote test station with key lock DH4000E-1 Weatherproof enclosure vs 02010 Sytr . Sensor, To W 3825 Ohio Avenue. St. Charles, IL 60174 Product spedfications subject to U EI1J.$OR0 Phone: 800-SENSOR2. Fax: 630-377-6495 current product Info a0onndod0rg the re vernon of rho date sheer. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE Im LISTING No. 13240-1653:020 Page 1 of I CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Modelo—D—N--Rl DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. 01-02-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL Pi FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. j 7300-1653:02 12 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models j RTSI 51 RTS1 51 KEY and RAI OOZ Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division