5411 AVENIDA ENCINAS; ; FPC2020-0144; Permit
4 PERMIT REPORT City of Carlsbad Print Date: 07/30/2021 Permit No: FPC2020-0144 Job Address: 5411 AVENIDA ENCINAS, CARLSBAD, CA 92008-4409 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2100904500 Track #: Applied: 08/20/2020 Valuation: $0.00 Lot #: Issued: 10/05/2020 Occupancy Group: Project #: Finaled Close Out: 07/30/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check#: Final Inspection: Project Title: Description: AVENIDA ENCINA FIRE ALARM Applicant: FPContractor: COSCO FIRE PROTECTION INC COSCO FIRE PROTECTION INC JAMES GRIMES 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (619) 508-9701 FEE AMOUNT FIRE Plan Review Per Hour - Office Hours $136.00 FIRE Reinspection (per inspection) $193.00 FIRE Sprinkler Monitoring $383.00 Total Fees: $712.00 Total Payments To Date: $712.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov F [010' 2-0 2-o 144- Fire alarm system cut sheets & California State Fire Marshal Listing sheets for: AVENIDA ENCINA 5411 AVENIDA ENCINA CARLSBAD, CA 92008 cosco Fire Protection 4990 GREENCRAIG LANE SAN DIEGO, CA92123 (858) 444-2000 F-1 rc-: Ki d d e . Technology that saves lives Conventional Fire Alarm Systems FX-1ORD, FX-1OR, FX-5RD, FX-5R Kidde Catalog t> Small Building Fire Alarm Solutions FDNY COA 6230 Overview Kidde brand conventional fire alarm systems consist of 5 and 10 zone fire alarm control panels (FACP), an optional integrated upload/download DACT (dialer), intelligent/analog type detec- tor features, serial annunciator modules, and serial remote relay modules. All FACPs and components are Listed to the 9th edition of the ANSI/UL 864 standard and CSFM/FDNY approved. These systems incorporate features designed to simplify installation, operation and maintenance, including front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with CleanMe® -compatible smoke detectors, these con- trol panels provide intelligent type features such as remote mainte- nance alert and automatic drift compensation that significantly reduce the chance of a false alarm and simplify maintenance calls. Kidde systems are powerful enough to meet the demands of today's life safety installations while leaving plenty of room to grow in the future. They support Class A operation by combining pairs of on-board lDCs or NACs to provide the necessary Class A circuits. For example, the FX-1ORD comes factory set to support 10 Class B lDCs and 4 NACs. But it can be field-configured to provide 5 Class A lDCs (no Class B IDC's), and 2 Class A NACs - or any other com- bination of circuits that fall within the circuit-pairing parameters. FX-10RD FX-5RD Class B lDCs Up to 10 Up to 5 Class A lDCs Up to 5 Up to 2 Class BNACs Upto4 Upto2 Class ANACs Upto2 1 __NZ Power 7.0 amps 3.5 amps Auxiliary power 0.5 amps 0.5 amps Notes: Class A operation will reduce the number of available Class B lDCs and/or NACs, depending on the panel configuration. See Specifications for details. Standard Features Available in 5, and 10 zone (lDC) models CleanMe® feature provides remote annunciation of a dirty detector Automatic drift compensation with select detectors reduces false alarms and extends dust life Listed to ANSI/UL 864 9th Edition Models with fully integrated upload/download DACT enables PC programming Zone or NAC pairs convertible to single Class A circuits Combination Waterfiow and Supervisory lDCs NACs programmable by zone and individually selectable for notification appliances, continuous, temporal outputs, or coded Front panel programmable simplifies installation and servicing Precision synchronization with compatible notification appli- ances and optional audible silence over two wires On-board relays for Alarm, Supervisory and Trouble Optional serial bus relay modules are programmable for Com- mon, Zone, or Matrix activation Optional serial bus remote annunciator family One person walk-test (audible or silent) Optional City Tie and Reverse Polarity Modules Trim ring available for semi-flush mounting Page 1 of 8 DATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 Application Kidde conventional fire alarm systems provide smoke and fire de- tection, occupant notification and off-premises signaling for small- to medium-sized buildings. Each IDC can be configured for either Class B or Class A opera- tion and one of eight operating modes: Alarm —with or without smoke detector verification including discrimination of contact devices Waterflow Alarm; Waterflow Alarm/Supervisory (Combination IDC); Supervisory (Latching/non-latching); Monitor (non alarm or supervisory) Signal Silence Drill Cross zoning NACs may also be configured for either Class B or Class A operation. Additionally, NACs can be individually configured for one of six outputs. These are Genesis, Genesis (A/V silenceable), Continuous, Temporal, Coded, and City Tie. The Genesis selec- tion allows independent horn control over two wires and provides precision synchronization of notification appliances, all without the need for a signal master accessory. When configured for compatible notification appliances, the Alarm Silence function will silence connected audible appliances but strobes will remain active until the panel is reset. When Genesis Mode is selected, both the horns and strobes on compatible notifi- cation appliances will be synchronized across all NACs. Note: Zones may be selected for either latching or non-latching operation. Always check with your AHJ regarding approval of silencing audible while leaving strobes flashing. Panel LED Display The following system LEDs display the panel's status: Alarm - panel is in the alarm state; Trouble - panel is in the trouble state; Supervisory - panel is in the supervisory state; Power - indicates the status of the AC power source; Disable - indicates when any IDC, NAC, relay or the DACT is disabled; Annunciator Trouble - indicates trouble on the remote an- nunciator bus; Battery Trouble - indicates battery or charging problems; Ground Fault - indicates a short between any panel circuit and ground; Walk Test - indicates that one or more lDCs are in the walk test mode; Alarms Silenced - indicates that the panel is in the alarm state with one or more NACs silenced. Waterflow - indicates that one or more circuits have detected an active waterflow switch. Service Detector - indicates the presence of a dirty detector with CleanMe® compatible ESL smoke detectors. Remote Disconnect - indicates off site communication has been disabled. Each IDC has a disable switch and three LEDs: Alarm - red - indicates that the IDC is in the alarm state; Trouble - ye/low - indicates that the IDC is in the trouble state or is disabled (when flashing); Supervisory/Monitor—yellow— indicates that the IDC is in the supervisory state or the monitor state (when flashing). Each NAC also has a disable switch and a trouble/disable LED. Detectors with intelligent features at a conventional price When combined CleanMe® : -compatible smoke detectors, ( Kidde systems provide intel- ligent features at a conventional prick If aCleanMe® detector drifts out of the UL sensitivity Replace/ range, Kidde's patented remote optical maintenance reporting sends an chamberl alert to the control panel. This - - feature reduces the chance of a / C) false alarm and simplifies service calls. In addition, CleanMe® -compatible smoke detectors have built-in drift compensation that extends the time between cleanings. If cleaning is ever necessary, it is literally a snap with the Kidde exclusive replaceable optical chamber. For a complete list of CleanMe® compatible smoke detectors, visit http://Kidde-fire.com. Status indication with the DACT/Dialer installed The optional upload/download dialer's LCD display provides two lines x 16 characters of text. For programming, the top line displays the programming step and the lower line displays the selected option. All system events are displayed on the LCD with custom zone messages. During normal operation, the LCD will display-any off-normal condition present in the panel. Page 2 of 8 D ATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 The DACT/Dialer installs be- hind the front panel display. Note: All panel versions are available with factory installed DACT See order table for ordering informa- tion. L. luy cli l even L. rl vi ilL)iO ULIUi i' II iL1U 0 Up to two split or dual reporting to two DACRs. RRM24s can be - mounted in an The DACT module can also be used FsRRM-SII snap track Up to two as a modem to connect the panel to FSRRM-SI1s can MFC-A. both local and remote computers for . RM be mounted in an uploading and downloading of con- figuration data (programming), panel The Remote Relay Module mounts on a plastic track inside an MFC-A cabinet. L I Power Connections Cabinet Main AC From 120 Vac, 15A, 60 Hz wiring block Dedicated branch circuit and fuse holder a Dual transformer AC wiring block Ic4J.I i J lI! . i• .tii / iI L__JI Main Tie wrap/ Main controller mounts \ trnfnrn.r board ® I Mounting studs Upload/Download DACT/Dialer Options Off-premise communication A fully integrated upload/download dialer is available for reporting events to a monitoring facility. The DACT also supports uploading or downloading of system configuration, status and event history. The DACT is programmable for either single or dual line opera- tion. It also supports split and dual reporting for two digital alarm receivers. The DACT brings additional features to the panel including a 32-character alphanumeric LCD display, local or remote PC pro- gramming and an event history log. Remote Annunciators and Relays The serial bus standard on Kidde conventional control panels is another installation time-saver. This circuit allows the connection of Remote System Indicators (FSRSI), Remote Zone Indicators (FSRZI- A, FSRZI-SA) and Remote Relay Modules (FSRRM24) over a four- wire (data and power) circuit. Annunciator and relay modules can be installed up to 1,000 feet from the panel on 18-gauge wire. Modules are also available for City Tie (CTM) and Reverse Polarity (RPM) connections. Remote Relay Module Fl The built-in DACT/Dialer is a multifunc- tion module that provides communi- cations, modem capability, and LCD display functions. Its primary function is as a Digital Alarm Communica- tor Transmitter (DACT). As a DACT, it transmits event messages to a Digital Alarm Communicator Receiver (DACR) at a monitoring facility. The monitoring facility then notifies the fire department and other responsible parties of the I. ,-..-.4 When configured in the common system mode, relays energize or de-energize when the panel changes status and event history. For security, Tonoxde5. state. One relay is available the modem can be configured to ac- commacaIone .>— Fi cornniwvnw- for each of the following cept programming on incoming calls cornnevlonln->--1 conc ion functions: Alarm, Supervi- or it can be required to call a prepro- pw sory, Trouble, Power Loss, >l Monitor. grammea number before accepting powe,ln I downloads and sending uploads. The DACT module can be configured to work as all of the above, or as only an LCD display or LCD display and modem. Page 3 of & DAIA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 The Remote Relay Module (FSRRM24) is one feature of the system that sets these systems apart from other panels in their class. This module has five Form C relays rated at 1 amp each. It can be configured to function in either a zone relay mode or a common system mode. When configured in the zone relay mode, relays energize when the as- sociated IDC is active. The module can be configured for activation by IDCs 1 through 5 or IDCs 6 through 10. One relay is automatically associated with each IDC. The FSRRM24 mounts on a plastic snap track and can be installed in an MFC-A enclosure. The panel will support two RRMs of each configuration for a total of six on the 10-zone panel. Remote Annunciators This family of systems has several remote annunciation options. The serial remote annunciator bus can be run up to 1000 feet (305 m) on untwisted . non-shielded 18-gauge cable. Several annunciator models round out the Fej- F family to provide a range of features and functions. As many as three an- nunciator modules may be mounted in a standard electrical box, sharing an attractive trim plate that blends with any decor. The FSRSI can be installed alone or with one or more FSRZI-As. The FSRSI and FSRZI-A require trim plates (ordered separately). These are available in one, two or three gang models. Each panel will support two FSRSls. Remote System Indicator - Remote Zone Indicator - j Remote Zone Indicator (FSRSI) (FSRZI-A) The FSRSI is ideal for The FSRZI-A is used to common system annuncia- F indicate zones in the alarm tion. It includes five LEDs state. It contains five red and a local silence/lamp LEDs. Depending on the test switch. The LEDs mdi- jumper setting selected, cate power status, alarm, -------. the LEDs will indicate either supervisory, trouble and >_, lDCs 1 through 5 or lDCs 6 ground fault. The silence cornana20oe,. >—i through 10. The panel can Cmauratonu. switch will silence the support two modules pro- onboard trouble sounder 'i grammed for each selection. if active. The switch can °'°' '°° 24 IN C IN also be used to initiate a NV IN C IN lamp test of the LEDs on + all connected FSRSls and FSRZI-As. P0.0,00+ Cor!,nUIcoIIer rut. P0+00,00. Ce,ak0+0+ C0+0SC.t00 ,. TO noun 0.000. . lb 0.0 0,010. FSUIM Graphic Driver/Interface The FSUIM is a universal interface module that can be used by to drive graphic annunciators. It also allows control panels to control, or be controlled by, other control panels. The FSUIM provides five supervised switch inputs and nine dry contact relay outputs. Nine LEDs provide visual confirmation when each relay is energized. The FSUIM is shipped with a plastic snap track for mounting in an MFC-A enclosure. FSRA10, FSRA10C Wiring control From panel r 24v 24v or 24vDc supply L 24 24V To next N.U.N.U. remote module From r IJ:l C control panel L c c r N.U. L ON: Group 1 OFF: Group 2 S Page 4 of 8 DATA Sl.1Fi K85005-0126 Not to be used for instalktion purpoc+&o. Issue 1 F (FSRZI-SA) The FSRZI-SA indicates zones in the Alarm or Su- pervisory state. It contains five red and yellow LEDs for Common, Zone, or Matrix activation. Depending on the J setting, the LEDs will COPe,j++00+10, indicate either lDCs 1- 5 or 6 Pe.oebn, - 10. The panel supports two modules for each selection, +,r,0040, 0001+0 and can be jumper selected 20000 to provide Alarm or Supervi- coop - sory indications. Canuru0ar 000 * FSRA10, FSRA10C Remote LED annunciators The FSRA10 is a remote annunciator with capacity for up to ten zones. It includes ten bi-color LEDs (red/yellow) for indicat- ing active zones, and ten yellow LEDs for indicating zone troubles. The (C) option adds common control switches. Both ver- sions mount to standard North American 4-inch square electrical boxes. A surface box is also available. Works only with 10 zone panel. From control panel Or 2400C power supply Control panel or 240CC power supply From control panel + To neat rem ose module C. C Remote Annunciator Specifications General Agency Listings I UL864 (S3000), ULC, CSFM Remote Annunciators FSRSI Remote System Indicator FSRZI-AJFSRZI-SA Remote Zone Indicator Maximum per System All panels: 2 10 zone panel: 4 5 zone panel: 2 Current Requirements Standby: 17 mA Alarm: 56 mA Standby: 8 mA Alarm 76 mA Voltage Range Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Maximum Circuit Capacitance 0.03 pF Maximum Circuit Resistance 13 Ohms Wire Size 18- 12 AWG (0.75 mm2 - 2.5 mm2) Mounting ANSI/NEMA OS1 -1996 1-3 gang electrical box Operating Environment Temperature: 32 - 120° F(0 - 49° C); Humidity: 93% RH, non-condensing Remote Relay Module - FSRRM24 Configured for Zone Mode Configured for Common Mode Maximum per system 10 zone panel: 4; 5 zone panel: 2 All panels: 2 Current Requirements Standby: 10 mA; Alarm: 70 mA Standby: 26 mA; Alarm: 70 mA Voltage Range Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Contact Rating 1 A@ 30 Vdc Maximum Circuit Capacitance 0.03 iF Maximum Circuit Resistance 13 Ohms Wire Size 18- 12 AWG (0.75 mm2 - 2.5 mm2) Mounting Single FSRRM24 mounts in plastic track (included) or up to two FSRRM24s in an FSRRM-S1 111" track ordered separately. FSRRM24s should be installed in an MFC-A enclosure. Operating Environment Temperature: 32 - 120° F (0- 49° C); Humidity: 93% RH, non-condensing Dimensions 2-3/4W x 3-3/8" H x 1-1/2" D (65.9 mm Wx85.7mm H x 38.1 mm D) F-Series Remote Annunciators FSRA10 FSRA10C Common Controls No I Yes Compatibility 10-Zone Panels Only. Dimensions 5-5/8 x 81/2 x 1 ½ in (14.3 cm 21.4 cm x 3.8 cm) Mounting North American 4-inch square electrical box Power Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) Data Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) twisted pair (6 twists per foot minimum) Operating voltage 18.8 to 27.3 Vdc Supply must be ULJULC listed for fire protective signaling systems. Do not use FACP accessory power outputs that are interrupted when the panel is reset. Standby current 17 mA Alarm current 98 mA Operating environment Temperature: 32 to 120 °F (0 to 49 °C); Humidity: 0 to 93% RH, noncondensing at 90 °F (32°C) FSUIM Universal Input Module Mounting MFC-A enclosure Wire size - 12 to 18 AWG (0.75 to 2.5 sq mm) Operating voltage 21.2 to 27.3 Vdc Circuit capacitance 0.03 pE, max. Circuit resistance 13 ohms, max. Switch inputs Quantity: 5 End-of-line resistor: 4.7 k ohms ½ W Relay outputs Quantity: 9 Type: Common Style: Form C Contact rating 30 Vdc at 1 A (resistive load) Standby Current 53 mA Alarm Current 114 mA Operating environment Temperature: 0 to 49 °C (32 to 120 °F); Humidity: 0 to 93% RH, noncondensing at 32 °C (90 °F) C Page 5 of B OAA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 C Dimensions Model D1* D2 D3 D4 D5* Five- 19.5 in 3.75 in 9.13 in 10.5 in 14.23 in zone (49.5 cm) (9.5 cm) (23.2 cm) (26.67 cm) (36.14 cm) Ten- 30 in 3.75 in 7.75 in 21.27 in 15.0 in zone (76.2 cm) (9.5 cm) (19.7 cm) (54.0 cm) (38.1 cm) *Add 1½ inches (3.81 cm) to Dl and D5 dimensions for trim kit D2 0•° 01 D4 Control Panel Specifications Control Panels FX-10RD FX-5RD Initiating Device Circuits - IDCs (Available combinations shown at right) Class B 10 8 6 4 2 0 5 3 1 Class A 0 1 2 3 4 5 0 1 2 Notification Appliance Circuits - NACs (Available combinations shown at right) Class B 4 2 2 0 2 0 Class A 0 1 1 2 0 1 Power Supply 7.5 amps total 4.25 amps total NAC Voltage Rating 24 Vfwr Maximum NAC current 2.0 amps each, 7.0 amps total 2.0 amps each 3.5 amps total AC Input 120 Vac 60 Hz... 230 Vac 50/601-lz... 2.2 amps 1.1 amps 1.25 amps 0.6 amps Base Panel Current Draw Standby... Alarm... 128 mA 242 mA 104 mA 224 mA Panel Battery Charge Capacity (sealed lead acid only) Up to two 24 Ah batteries, 18 Ah in cabinet Up to 24 Ah, 10 Ah max in cabinet * Auxiliary Current 0.5 amps max. May be programmed as resettable. Auxiliary Output 24 Vdc regulated IDC Alarm Current 3.0 mA (Consult detector compatibility list p/n 3101019-EN for maximum detectors per circuit) DC Circuit Maximum loop resistance: 26 Ohms; Maximum loop capacitance: 0.03 pF IDC Operating Voltage 16.9 to 29 Vdc UL Detector ID 100 Alarm Contact (normally open Form C) 30 Vdc © 1 A (resistive load) Trouble Contact (Form C) 30 Vdc © 1 A (resistive load) Supervisory Contact (normally open Form C) 30 Vdc © 1 A (resistive load) Operating Environment Temperature: 32 - 120° F (0- 49° C); Humidity: 5 - 93% RH, non-condensing Terminals (wire gauge) 18- 12 AWG (0.75 mm2 -2.5 mm2) Asynchronous Serial Communications Maximum resistance: 13 Ohms; Maximum capacitance: 0.03 pF Agency Listings I UL864 (53000), ULC-S527, CSFM, FDNY * /f larger batteries are required, use an external battery cabinet. DACT - F-DACT_ (mounts _in_panel) Receivers Supports two receivers with two phone numbers each Communications Protocol Contact ID (SIA DC-05), 4/2 (SIA DC-02 P3) Programming Front panel controls or PC with appropriate software Telephone line connection Two RJ31X (plug-to-plug) cords supplied with DACT Telephone lines Two or one loop start lines on the public switched telephone network. Pulse or DTMF. Telephone wall connector RJ31X1CA31X equiv. or RJ38X/CA38X equiv. Communications Compliance Industry Canada CS-03; FCC/CFR 47 Parts 15 & 68; NFPA 72; UL 864; ULC S527 Operating Environment Temperature: 32-120° F (0-49° C); Humidity: 93% RH, non-condensing Current requirements Standby: 65 mA; Alarm: 107 mA Agency Listings I UL864 (S3000), CSFM, FDNY Page 6 of 8 DATA S HE E -, K85005-0126 Not to be used tot instailation purposes. Issue 1 Ordering Information Part Description Ship Wt. lb. Number (ka. Control Panels Conventional Fire Alarm Control Panel, Red - 10 Class B lDCs and 4 Class B NACs, 7.OA NAC power, (Pairs of FX-10RD lDCs and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 30.5(13.8) 24VDC output Conventional Fire Alarm Control Panel, Red - 5 Class B lDCs and 2 Class B NACs, 3.5A NAC power, (Pairs of lDCs FX-5RD and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 24VDC 24.4 (11.1) F-TR1M35R Semi-flush trim ring for FX-5RD 1.7(0.8) F-TRlM10R Semi-flush trim ring for FX-10RD 2.2(1.0) Note: remove "Din model number to order panel without the upload/download dialer in the panel Related Items F-XTR120 Expander Transformer, 120 Vac - For FX-10 only 4.0(1.8) EOL3 6-1 1 Required UL listed End of Line Resistors - One 3.6K Ohm and one 1.1K Ohm. 01 (0.5) One required for each IDC configured as combination waterflow and supervisory. EOL-P1 Required ULC listed End of Line Resistor Plate - includes one 1.1K, 3.6K and 4.7K Ohm resistor 1.0 (0.5) Off Premises Communications F-DACT Upload/dowload digital Communicator/modem/LCD module (Mounts in control panel) 1.0 (0.5) CTM City Tie Module (Requires 4" square or 2-gang North American electrical box) 1.0 (0.5) RPM Reverse Polarity Module (Requires MFC-A or other listed fire alarm enclosure) 3.0(1.4) Remote Annunciation FSRSI Remote System Indicator - Includes LEDs for display of Power, Alarm, Supervisory, Trouble and Ground Fault, trouble sounder and silence/lamp test switch. Single gang trim plate included, multi-gang plates ordered separately. Mounts in a single or multi-gang North American electrical box. 0.3 (0.1) FSRZI-A Remote Zone Indicator - Includes red LEDs for five lDCs. Single gang trim plate included, multi-gang plates ordered separately. Mounts in single or multi-gang North American electrical box. 0.3(0.1) FSRZI-SA . Remote Zone Indicator - Includes LEDs for five IDCs. Single gang trim plate included, multi-gang plates ordered separately. Mounts in single or multi-gang North American electrical box. Jumper selected Alarm (red) or Supervisory (amber) indications. 0.3 (0.1) FSAT1 Annunciator Trim Plate, 1 gang 0.1 (0.05) FSAT2 Annunciator Trim Plate, 2 gang 0.1 (0.05) FSAT3 Annunciator Trim Plate, 3 gang 0.1 (0.05) FSAT4 Annunciator Trim Plate, 4 gang 0.1 (0.05) FSRA1 0 Single Unit 10 zone remote annunciator for FX-10 K-FSRA1OC Single Unit 10 zone remote annunciator for FX-10 (with common controls) K-FSUIM Common Function Graphic Driver/Interface - 9 relays and 5 switch inputs for common system indicators and controls Remote Relay Module FSRRM24 Remote Relay Module - Five Form C relays. Configurable for lDCs 1-5, or 6-10, or common system indications or matrix mode-Requires MFC-A or other listed fire alarm enclosure. 0.4(0.2) FSRRM-S11 11" Mounting track. Holds up to two FSRRM24s. 0.4 (0.2) Accessories MFC-A Multi-function Cabinet (fire alarm accessory enclosure) . 7.0 (3.2) Page 7 of S DATA SHEET K85005-0126 Not be used tar nstalatiori purpose. Issue 1 e 9 Kidde (i.tinininitnrni Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: Kidde.com/EnqineeredSystems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 8 of 8 DATA SHEET K85005-0126 Not to be used for intallation purposc. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0102 Page 1 of I CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models FireShield series FS302x, FS502x, FS1004x, *Models FireShield Plus FSP302x, FSP502x, FSP1004x, *Models FireworX series FX-3x, FX-5x, FX-10x and *Models FSC- series E-FSC302x, E-FSC502x, E-FSC1004x fire alarm control units. The suffix x' may include any of the following alpha and/or numbers: G, R, G-2, GF, GD, RD, GC or *F. Models FSDACT and *F.DACT digital alarm communicator transmitter. Local, auxiliary, central station, remote station, automatic, manual, waterfiow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. *This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-1591:102, 7165-1501:129 7-29-10 ma Tf This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division TG=7FS LTE-A P/N:TG7LAF01 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD ó COMMERCIAL FIRE PRODUCT FEATURES Certified for use on the AT&T LIE network for long, sunset- free installation. P Meets UL 864 requirements for sole, primary or backup path communications. I- Minimizes false alarms by providing dual paths for self-tests. I Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LIE-A can serve as the sole communications path for the fire alarm system. It replaces all of the land lines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-A because of the new sixty minute supervision mode. The TG-7-F-S-LT-E-A can also be installed as a backup path and upgraded— - to sole path at a later date. S el Gar II1UIPSIce l elgil (OR Ti1ar rVi TV,dgi AT&T LIE networ co e or all Teiguaj nits. e guar €ojflrnication Genter com e ai!1, e 1g1 dIa i P prod a s nd tl!e ent al statlo. el e iica upport provid in le Poif contact or bat ell la seje ndguar o__t1 queio..ns. a TR9ht - o iIU1ji 1hflE bi1tJt l aix xTh o I1t1 flIiMt i Ijjni TG=7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD , 'i1 13!Iiilit.Ji} j iit iE!. axs I U 0 o Ua a é?ti AuoiDatl eI f- firs t (60 mm. Loc in ed metal nc1bs re. Two pr amm l5j urDT trIIIp óu S Aarm or iipprt for SVA'2 .0 a . : I I ME 91 IN elUhon mn onitor ilt'jn,_ ith Saü. Lje Sety. A Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. UL Listings Commercial Fire 864 Control units & --accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning-systems 1023 Household burglar alarm systems ULC Listings S545 • Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.Telguard.com. Telguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE • Suite 300 Atlanta, GA 30339 • USA 800-229-2326, Option 5 • www.Telguard.com Copyright @2017 Telular Corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL @ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models TG7LAA02, TG7LA001, TG7LAA0I, TG7LA002, TG7LAF01, TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF01, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 11-27-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division SYSTEM SENSOR® Photoelectric Smoke Detectors System Sensor j3 series smoke detectors represent significant advancement in conventional detection. The il family is founded on three principles: installation ease, intelligence, and instant inspection. S S Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings & <~> 0 MEA MSFM c00- LISTED APPROVED approved approved 5911 3011446 7272-1653152 290-01E 2093 3180932 Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. P detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module ora panel equipped with the P protocol. The SENS-RDR, a wireless device, displays the sensitivityof i detectors in terms of percent-per-foot obscuration. Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the j3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Cj) Smoke Detector Specifications S Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 1 35°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum: 35 V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @30 V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2VVT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2VVT-B and 4VVT-B only: 41°F (5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control oanel 4W-B No 4-wire 20mA@12'23mA@24V 4VVT-B Yes 4-wire 20 mA @ 12V, 23 mA @ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter . T"\ SYSTEM °2OO9 Sytern Sensor. 3825 Ohio Avenue St. Charles, IL 60174 rrodoctspeoSc000nssobjnatoohooge without notice. vasvrernsensor.00rnfor Phone: 800-SENSOR2. Fax: 630-377-6495 cornsprododrnro5OOSon including the tert version of this drtosheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL tR FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models 2W-13, 2WT-B, 4W-13 and 4WT-13 photoelectric type smoke detectors. Models 2W-113 and 2WT-B are 2-wire and model 4W-13 and 4W1-B are 4-wire detectors. Models 2WT-B and 4WT-13 employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 S 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division