2525 EL CAMINO REAL; 134; FPC2019-0167; Permit
PERMIT REPORT (ity of Carlsbad Print Date: 01/25/2022 Job Address: 2525 EL CAMINO REAL, # 134, Permit Type: FIRE-Construction Commercial Parcel #: 1563022700 Valuation: $42,649.67 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: BROWS N MORE - FIRE ALARM TI CARLSBAD, CA 92008-1207 Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0167 Status: Closed - Finaled Applied: 07/23/2019 Issued: 07/30/2019 Finaled Close Out: 02/05/2021 Inspector: Final Inspection: Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov tqcti SimplexGrinnell SimplexGnnnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgtinnell.com Fire Detection and Alarm System Product Submittal Project: Brows N More The Shoppes at Carlsbad 2525 El Camino Real Suite #134 Carlsbad, CA - -- FPC2OI9-0167 2525 EL CAMINO REAL #134 BROWS N MORE - FIRE ALARM TI 1563022700 7129/2019 FPC20I9-0167 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douqlas.danielsäjcj.com 7/22/2019 REV.#: 0 PROJECT Safer. Smarter. Tyco.M tycci SimpiexGr!nneli SirnplexGrinnell LP 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www.simplexgtinnell.com Fire Detection and Alarm System Products Qty Model No. Description 1 4098-9755 Duct Detector 1 2098-9806 Remote Test Station/LED 2 4090-9010 Relay lAM 1 4906-9204 Strobe 2 49SV-APPLC Speaker Strobe C.S.F.M. No. 3420-0026:0241 7300-0026:0150 7300-0026:0311 7125-0026:0235 7125-0026:0384 Business Information Warranty Information 7/22/2019 REV.#: 0 PROJECT Safer. Smarter. Tyco.' II7T!F1Ii Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) ITTT4iflfl9 TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. IITiMe- Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. ItTF1I . Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor information in plain English language Relays of model 4098-9756 are under panel control Duct Sensor Selection Chart Duct Smoke Sensor Housing with Photoelectric Sensor* Model Basic Duct Sensor Housing; operating power is supplied by 4098-9755 either IDNet or MAPNET II communications (no relay output) Compatibility Simplex fire alarm control panel models: 4I00ES, 40I0ES, 4008, 4010, 4100U, and legacy products 4020, 4100/4100+, and 4120. Also 2120 CDT if configured for MAPNET II, TrueAlarm operation Same as above except relay operation is not Duct Sensor Housing with supervised multiple relay output, compatible with 2120 CDT; 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 I Relay output is for up to 15 total 4098-9843 Relays end-of-line resistor harness; includes one 4098-9843 relay (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description 2098-9808 Red LED status indicator on single-gang stainless steel plate Test Station with keyswitch and red LED status indicator, on 2098-9806 single-gang stainless steel plate; (turning switch to 'TEST" initiates alarm for system testing) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 4098-9843 for additional relay information; one included with 4098-9756; wiring is 18 AWG (0.82 mm2 ) color coded wire leads Compatibility Mounting Use single gang box, 4098-9755 3" Hx2"Wx2"D 4098-9756 I (76 mm x 51 mm x 51 mm) Compatibility Location 4098-9756 only; Locate relays within 3 ft connect up to 15 (1 m) of device being controlled per NFPA2 4081-9008 End-of-Line Resistor Harness; 10 kg), 1/2 W; (ref. 733-894); 4098-9756 At last relay location I required to supervise remote relay coil connection * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Sampling Tube Selection Chart, Ordered Separately Per Duct Width, Select One Overall Duct Width (305 mm) Tube Required 4098-9854 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 4098-9855 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 4098-9856 3 in" (76 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 4098-9857 3 in" (76 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 4098-9858 3 in" (76 mm) longer than duct width S4098-0030-9 11/2012 Duct Sensor Housing, Front and Bottom View 0 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station S1IItNIIS Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. Ill -..1iii. Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. B$implEx TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved,- Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control Ihui-i Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNet or MAPNET II, 2-wire communications Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNet/MAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4098-0030-9 11/2012 I F-XRRR--T MUM NOTE: Refer to InstaIIaton Instructions 574-776 for additicnal installation detail and maintenance information. 1 11-3/8" (289 mm) FExhaust tube access hole) r"l Conduit (by others 40 in 6-3/4' (171 mm) access hole (Stationary baffle 3-3/8" (86 mm) 4 Smoke sensor, mounted I interface base (supplied) Metal plate with dual holes pplied for unused hole LED, relay control trouble tor (4098-9756 only) sensor s LED Wring terminals) .in) aptive fastening screws (4) (Magnetic test area) NOTE: Orientation shown is for reference [Transparent cover) [Gasketed ser sor area) only, refer to General Location Notes and / End View illustration below for alternate mounting reference. (21 mm) I Test ports (2) providec for measuring airflow and for aerosol injection Sampling tube, ordered separately per duct width 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 1-3/16" (30 mm) 1-1/2" 13/16" (38 mm) (21 mm) reference outline Alternate location (if aoororiate) 18" Round duct outline (minimum diameter) — — — — — — — - - - housing _______ haust tube 8" Square duct outlilel I Sampling tube, keyed for proper flole alignment with holes facing into airflow (template is provided for proper tube installation). (Housing is shown as position 2 per note 2 below.) General Location Notes: Testing performed under the auspices of the Fire Detection Institute (FDI) recommended when sampling tubes are not located vertically, that they be positioned horizontally in the upper half of the duct to account for possible stratification. Three duct side mounting options are available as shown below. Mount housing at 90° to airflow for all orientations. Arrows indicate allowed airflow directions. x DO NOT MOUNT ON BOTTOM OF DUCT /\ S4098-0030-9 11/2012 -0 Supply Air 'or OK Retum Air + Exhaust Fresh air - Do not locate Filter bank Sensor OK sensor here Duct Sensor Location Reference Additional Information. Refer to NFPA 90A, Standard for the Installation ofAir Conditioning and Ventilating Systems; NFPA 72, the National Fire Alarm and Signaling Code; and the NEMA Guide for Proper Use of Smoke Detectors in Duct Applications, and Installation Instructions 574-776. Duct Sensor Location Considerations: Proper duct smoke detection location must ensure adequate airflow within the duct housing. Duct air velocity rating is 300 to 4000 ft/min (91 to 1220 nilmin). Pressure differential between intake and exhaust tubes is required to be between 0.015 to 1.55 inches of water (0.381 to 39.37 mm). Ensure accessibility for test and service. Proper Locations: downstream side of filters to detect fires in the filters; in return ducts, ahead of mixing areas; upstream of air humidifier and cooling coil. Other locations and orientations may be required for proper duct smoke detection depending on duct access, system design, and duct airflow testing. Contact your local Simplex product supplier for assistance. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Specifications General Mechanical and Environmental Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Black base with clear cover Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation Data Communications lDNet or MAPNET II communications, auto-select, one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current 3 mA @ 24 VDC Alarm Current 15 mA @24 VDC; add 15 mA for each 4098-9843 relay Supervised Remote Relay Control Output For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 it (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 kn, 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current 15 mA @24 VDC, up to 15 maximum per relay control output Relay Contacts 7 A at 0.35 PF @ 28 VDC & 120 VAC; 250 jiA @ 5 VDC Location Distance 500 ft (152 m) maximum to relay coils; locate relays within 3 ft (1 m) of device being controlled per NFPA 72 TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). Si ni I E Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4098-0030-9 11/2012 www.simplexgrinnell.com 02012 Tyco Fire Protection Pmth.wcv. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette©jci.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. NOTE: *Rev. 05-12-2003 s This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:0241 Page I of I CATEGORY: 3240 - DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexl0o Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models 4098-9755, *4098..9755T5p *40989755up 4098-9756, *4098..9756T5p *4098..9756up 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 -4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VI operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division fiSimplEx Multi-Application Peripherals UL, ULC, CSFM Listed, IDNet Communicating Devices FM Approved* Model 4090-9010, 8 A Relay lAM IItii*i Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 srrintie 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. II1 Model Description 4090-9010 8 A Relay lAM Optional Trim Plates and Adapter Model Description 4090-9801 For semi-flush Trim plate, galvanized mounted box steel, with LED viewing For surface window; includes 4090-9802 mounted box mounting screws Adapter plate to fit 4 11/(119mm) square 4090-9813 electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) IDNet communications I address per Communications device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type Separate contacts; 1, NO and 1, NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4WHx4"Wxl %"D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) S4090-0015-1 11/2014 8 A Relay lAM Mounting Information 4" (102 mm) square box, 2-1/8 (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate I © © H I © © -- WA - Add supplied label to I WA FMM 1 I I ia- -.i 1"M M81=1811 I IAVnSSaeIT: cover on-site if controlling IAvwrIssae(r•I 4-9/16' 120 or 240 VAC 4-5/16" (116 mm) (109mm) Light pipe for LED viewing © © © © 1 4-9/16" (116 mm) 'ii 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. S.Simplex Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4090-0015-1 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4090-9118 relay IAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay lAM, *4090..9010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division thSimpIEx TrueA!ert Addressable Notification Appliances UL, ULC, CSFM Listed; FM Approved; [TI Multi-Candela Visible Only (V/O) MEA (NYC) Acceptance* IV - fti Appliances (Strobes), Ceiling Mount Ihui*i Individually addressed and controlled multi-candela V/O (visible only) notification appliances provide: Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, or 110 cd Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup Wiring supervision to each strobe allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 2) Magnet test diagnostics to assist checkout and testing of appliances and wiring Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable systems for upgrade and replacement (see page 3) UL listed to Standard 1971 and ULCS526* LED indicator and magnet test feature: Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address AND pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features: Rugged, high impact, flame retardant ceiling mount thermoplastic housings are available in red or white Rear of housing does not extend into box and easily mounts to standard electrical boxes Mounting options include red wire guards and adapters for surface mounted electrical boxes * See page 2 for wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:235 for allowable values and/or conditions concerning material presented in this document Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Ceiling Mount Addressable V/Os I'i*iEPt1 Multi-Candela TrueAlert addressable strobes provide convenient installation to standard electrical boxes. The strobe is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 3.) Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). II TrueAlert addressable appliances on IDNAC SLCs provide separate visible (and audible) notification using a single two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity, by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. S4906-0004-4 2/2015 Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. gTrr Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (Refer to data sheet S4905-0001 for additional information.) am- irvr Test Features. Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test. In this test mode, in response to the magnet test, the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Testing. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT). The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. Product Selection -- Multi-Candela Ceiling Mount Addressable Strobe Model Housing Color FIRE Lettering Dimensions Description 4906-9202 Red White 4 3/ X 2 4 16 X 2 8 ID White Red (121 mmx75mmx67mm) Multi-Candela Addressable Strobe; intensity selectable as: 15, 30, 75, or 4906-9204 110 candela VIO Adapters (see diagram on page 3) Model Description Dimensions 4905-9910 Ceiling Mount, Surface Mount Adapter Plate, zinc plated; required for 4%" x 3 /" (124 mm x 79 mm) ceiling surface mount Wire Guards (see diagram on page 3) Model Description Dimensions 4905-9926* Ceiling Mount Red wire guard with mounting plate, compatible with 6 1/8 x 4 %" x 2 /" semi-flush or surface mounted boxes (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc TrueAlert Device Reports Reference Service REPORT 5 Port : TrueAlert Device Report Page 1 12:34:56am TUE 27-Jan-15 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA T14-1-1 Location Label . . . up to 40 characters V/O 15 T14-1-2 Break Room 5 A/V 110 T14-1-3 Boiler Room A/V 75 T14-1-4 Elec. Room 7 A/V 30 2 S4906-0004-4 2/2015 Ceiling Mount V/O and Guard Installation Reference i Handy box, 1-1/2 (38 mm) deep (RACO 650 or Single gang box (Wiremold V5744S) -4-L. equal) or single gang box, 2-1/2" (64 mm) deep 2-1/4 (57 mm) deep, supplied by others (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop Address setting DlPswitch is behind strobe I k-' ____________________ ) ceiling T-bar with clips (ERICO No. 512 or equal) assembly, select address and strobe candela setting before inserting into housing 4905-9910 Adapter Plate, required for surface mount with handy box unless using the 4905-9926 7 wire guard Bottom view Magnetic Ceiling mount strobe test location Optional 4905-9926 wire 1 guard with mounting plate ----------------------------------------- ho L. -k 7 ------ Strobe intensity viewing slot lntensity selection plug, - 1 L . accessible only from rear of lens / housing; factory setting is FACP, LED indicator/ ) - controlled by panel ----------------- IDNAC SLC Controller Compatibility Reference - Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC S4010-0011 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4007ES with IDNAC Notification S4007-0002 401OES with ESS Enhanced System Supply I Specifications General Specifications (see page 2 for dimensions) Environmental 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm 2); two wires per terminal for in/out wiring Installation Instructions 579-808 Strobe Specifications Typical Operating Voltage Range 23 VDC to 31 VDC, Special Application (see below for 17 VDC rating) Supervisory Requirements I unit load (= 0.8 mA control panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 46 synchronized strobes maximum per MAC Candela Setting 15 c I 30 c I 75 c 110 c 23 VDC RMS Current Ratings, for connection to IDNAC Addressable SLCs 60 mA 92 mA 180 mA 240 mA TrueAlert Strobe LEGACY Compatibility Reference Compatible Controller Data Sheet Reference Controller Output Available Strobe Intensity Appliance Voltage Minimum 4IOOES or 4100U with TrueAlert Power Supply S4100-0031 TrueAlert Addressable SLC 15, 30, 75, and 110 c S4009-0003 .17 VDC 4009 TPS, Remote TrueAlert Power Supply S4100-0037 TrueAlert Addressable Controller (4009T) Electrical Ratings Difference for Retrofit Applications Voltage Range 17 VDC to 31 VDC, Special Application Candela Setting 15 c 30 c 75 c 110 cd 17 VDC RMS Current Ratings, use when connected to TrueAlert Addressable SLCs per 76 mA 128 mA 242 mA 328 mA above S4906-0004-4 2/2015 TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). ®S i Ffl p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 • USA S4906-0004-4 2/2015 © 2015 Tyco Fire Protection Products. All rights reserved All specficati,ns and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0235 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models "TrueAlert non-addressable "4904-9331, 4904-9342, 4904-9332, 4904-9343, 4904-9333 and 4904-9344 synchronized strobe lights. Models "TrueAlert non-addressable" 4904-9168, 4904-9171, 4904-9169, 4904-9172, 4904-9170 and 4904-9173 non-synchronized strobe lights. Models "TrueAlert addressable" 4904-9350, 4904-9351, 4904-9352, 4904-9353, 4904-9354, 4909-9355 synchronized strobe lights. Models "TrueAlert addressable" 4904-9356, 4904-9357, 4904-9358, 4904-9359, 4904-9360, 4909-9361 synchronized strobe lights. Models "TrueAlert addressable" 4906-9201, -9202, -9203, -9204, and -9208 synchronized multi-candela strobe lights are intended for indoor use. *Models 4906-9201, -9203 and -9208 are intended for wall mount only. *Models 4906-9202 and -9204 are intended for ceiling mount only. Intended for use with either Model 4209-9401 NAC Extender or with the TrueAlert power supply of Model 4100U fire alarm control panel. Model 4906-9208 employs two lenses, clear lens for "Fire" and amber for "Non-Fire". Model 4905-9938 sync control module. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 4904-9331, -9342, -9350, -9353, -9356, -9359, -9168, -9171: 15cd, 1 Hz. 4904-9332, -9343, -9351, -9354, -9357, -9360, -9169, -9172: 75cd, 1 Hz. 4904-9333, -9344, -9170, -9173, -9352, -9355, -9358, -9361: 110cd, 1 Hz. Models 4906-9201, -9202, -9203, -9204, -9208: 15, 30, 75, 110cd, 1 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Intended for indoor use and wall mounting only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired when used with listee's separately listed fire alarm control units. For "TrueAlert non-addressable" synchronized strobes, Model 4905-9938 sync control module must be used. *Rev 04-02-15 gt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division B SimplEx TrueA!ert Addressable Notification Appliances UL, ULC Listed* Wall and Ceiling Mount Addressable Speaker and Speaker Visible Notification Appliances I1ijii*i Individually addressed and controlled Speaker (SIO) and Speaker Visible (SN) notification appliances Advanced addressable notification controlled by IDNAC SLCs provides regulated 29 VDC for low current operation even under battery backup. Wiring supervision is electronically monitored and allows audio wiring to be T-tapped for class B wiring, reducing wiring costs and wiring distances. Speaker selectivity is controlled by the panel. Only those speakers that are needed are connected to the audio NAC. Separate appliance and cover selection greatly simplifies the ordering and installation process. Strobe intensity can be programmed from the control panel or the device for S/V models. Self-Test Mode allows on-board sensors to detect the strobe and speaker output and then report their status to the control panel. Wiring terminals separate from the Audio terminals. TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting. Magnet test diagnostics to assist checkout and testing of appliances and wiring. Compatibility with ADA requirements. LED indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address and pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount models Covers are available in red or white with various lettering options Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts to 4" square 2 '/" gang US electrical boxes * Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Ceiling and Wall Mount Addressable Speaker Only and Speaker Visible Strobes Speaker design features High quality voice and tone reproduction with taps for Vu, '/2, 1, or 2 W, at 25 or 70.7 VRMS Speakers have capacitor input for connection to DC supervised NACs and are wired separately from strobes Listed to UL 1480 and TJLC S541* Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas High and low frequency response models available, 200-10000 Hz and 400-4000 Hz respectively. IIL*i.iI.1Ti1i1 Wall and ceiling mount addressable speaker and speaker visible appliances provide convenient installation to standard electrical boxes. The speaker is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel IDNAC Signaling Line Circuit (SLC). Audio is provided by a panel that supports audio output or from a separate audio source. Appliances use a multi-tapped speaker for audio/tone notification. Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117. 1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S49SWC-0001-1 11/2015 Il'].I1sIsjoIi itLL1iT TrueAlert Addressable speaker and speaker visible appliances on IDNAC SLCs provide visible and audio notification using two separate two-wire circuits that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. - Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet S4905-0001 for additional information. IITT Fill] P*IiI'1 IT Test Features Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the appliance's address when a magnet is applied. Operational Appliance Testing In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. Wall Mount SIC Appliances* (Refer to data sheet S49SOW-0001 for full product selection including covers and mounting plates) Model Dimensions Description Data Sheet Reference 49S0-APPLW(-BA) 5 'A" H x 5" W x 1 /z D S/O appliance only S49S0w-0001 49HF-APPLW(-BA) 1(139 mm x 128 mm x 38 mm) High fidelity S/O appliance only Wall Mount SN Appliances* (Refer to data sheet S49SVW-0001 for full product selection including covers, mounting plates, and multi-color strobe lens) Model Senes Dimensions Description Data Sheet Reference 49SV-APPLW(-BA) 7 %" H x 5" W x 1 %" D I SN appliance only 49 49HFV-APPLW(-BA) (187 mm x 128 mm x 43 mm) I Hicih fidelity SN aDDliance only *Note: Wall mount models require separately ordered back plate. See related datasheet for details i Mount AnnIiin'c Prot1iitt St -tic Ceiling Mount 5/0 Appliances (Refer to data sheet S49SOC-0001 for full product selection and installation requirements) Model Dimensions Description Data Sheet Reference 4950-APPLC(-BA) 7 %' H x 7 %" W x 1 1/4 D S/O appliance only S49Soc-0001 49HF-APPLC(-BA) (180mm x 180 mm x 32 mmft1igh fidelity S/O appliance only Ceiling Mount SN Al Model Series 49SV-APPLC(-BA) 49HFV-APPLC(-BA) 49SVH-APPLC(-BA) 49HFVH-APPLC(-BA) 49HFVH-APLCA-BA 49HFVH-APLCB-BA lances (Refer to data sheet S49SVC-0001 for full product selection and installation requirements) Imensions Description Data Sheet Reference SN aooliance only I High fidelity SN aDoliance only I 8W'Hx7WWx3"D (206 mm x 180 mm x 76 mm) Amber lens high fidelity hi(, Clear lens high fidelity higi SN appliance only S49SVC-0001 candela SN appliance on Blue lens high fidelity high SN anoliance only Note: Select appliance, cover and mounting back plate (where required) separately. (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are assembled in the USA S49SWC-0001-1 11/2015 IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage Design Reference 4IOOES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4100ES Flex 35, 50, and 100 Amplifiers S4100-0034 4IOOES Constant Supervision and Signal Cards Specifications General Specifications (refer to individual model data sheets for further specifications, install and operation details) Typical Operating Voltage Range 23 - 30 VDC, Special Application Environmental 32° to 120 F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mmd); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible fire panel installation instructions for circuit current load limits. Speaker Specifications Input Voltage 25 or 70.7 Vrms Power Taps 1/4,/2,1, and 2W 400 to 4000 Hz and 200 to 10000 Hz, Frequency Response General Signaling = 125 to 12 kHz Strobe Specifications Typical Operating Voltage Range 23 - 30 VDC, Special Application Supervisory Requirements I unit load (= 0.8 mA control panel current) Flash Rate 1 Hz IDNAC SLC Wiring Specifications (refer to control panel installation instructions for more information) UTP, unshielded twisted pair recommended Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = 10,000 ft (3048 m) Maximum wire length to any appliance = 4000 ft (1219 m). This can be doubled to 8000ft (2438m) by using a 4009 IDNAC Repeater. Note: Speakers are for connection to compatible fire alarm audio circuits only. S49 Series Speaker Datasheet Reference Model Data Sheet Reference Wall Mount Speaker Only Appliance S49SOW-0001 Wall Mount Speaker Visible Appliance 5495VW-0001 Ceiling Mount Speaker Only Appliance S49SOC-0001 Ceiling Mount Speaker Visible Appliance S49SVC-0001 S49SWC-0001-1 11/2015 TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). G.Simplex Tyco Fire Protection Products• Westminster, MA • 01441-0001 USA S49SWC-0001-1 11/2015 www.simplex-fire.com 0 2015 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models: 49SV-APPLC,49HFV-APPLC,495V-APPLC-BA49HFV-APPLC-BA,49SVH-APPLC-BA, 49HFVH-APPLC-BA,49SVH-APPLC,49HFVH-APPLC,49SV-CWF,49HFV-CWF,49SVH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mounted Speaker/Strobes. Models: 495V-APPLW,49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW-BA,495V-WRF, 49HFV-WRF, *49SvAppLw0 *49SVAPPLW0BA *49SVAPPLWCO True Alert ES, Addressable wall mounted Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor and outdoor use. Refer to listee's Installation Instruction Manual for details. *Revision 04-17-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's 'data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILL.O, Program Coordinator Fire Engineering Division SimplexGrinnell LP 3568 Ruffin Road, South tq iLi San Diego, CA 92123-2597 Tele: (858) 633-9100 ell Fax: (858) 633-9101 www.simplexgrinnell.com License 986047 Number Business Information JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2019 This license is current and active. All information below should be reviewed. C1 - ELECTRICAL C16 -FIRE PROTECTION CONTRACTOR. Bonding Information Contractors Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Bond of Qualifying Individual This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for TIMOTHY PAUL ROSTEN in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 YAYIIIlflhSI.1nhsrJeI*u[.1i This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC308342 Effective Date: 10/01/2016 Expire Date: 10/01/2017 Workers' Compensation History F -- Other Personnel listed on this license (current or disassociated) are listed on other licenses. .9/1/2017 . . . REV.#: 0 PROECT#: 480-XXXXXX-XX/X)O(XXXXXX i-'ersonnel listed on this license (current or disassociated) are listed on otner licenses. tqcci ell SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST 10/4/2016 REV.#: 0 PROJECT #: 480-XXXXXX-XX / XXXXXXXXX